PBX Secure Standard83240 Part number 83240223
Dimensions according to standard DIN 41 636 type F
Positive break operation mechanism according to IEC 60947-5-1 Annex K
Double break changeover switch with electrically separated circuits (form Zb)
IP 40 or IP 67 / IP 65 versions
Operating temperature between -50 and +85 °C
Long overtravel
Standard or Low level version
Part numbers
Specifications
Type
Degree of protection mechanism - connection
Connections / Accessories
83240223
Standard83240
IP 67 / IP 65
-
IP 00
W5 + Lever
Electrical characteristics
Direct opening action
Rating nominal / 250 VAC (A)
6
Rating nominal / 250 VDC (A)
0.6
Rating thermal (A)
10
Operatingrange/4→30VDC/AC(A)
-
Mechanical characteristics
Maximum operating force (N)
4,5
Minimum positive opening force (N)
28
Maximum rest position (mm)
8,9
Operating position (mm)
6,6
±
0.25
*
Positive opening position (mm)
4,4 *
Maximum end of travel position (mm)
3,4 *
Differential travel (mm)
1
±
0,3
Operating temperature (°C)
-
50→+85
Mechanical life (operations)
107
(IP40)
4x10 6
(IP 67)
Contact gap (mm)
2 x 1
Max. tightening torque (Nm)
1.3 on Ø 4.1 holes
Weight (g)
22 *
Comments
* Values given for versions without lever (in relation to the reference dimension X0 -
See Dimensions section).
Additional characteristics
Components
Material
-
Case/cover : PC GF 20 FR. (UL 94
-
V0, GWFI 960 °C, NFF 16
-
101/102 I2F1)
- Contacts : AgNi for Standard version and AgPd for low level version
- Terminals : Brass
-
Button membrane : Silicone
- Screws : zinc protected steel (stainless steel on request)
Conformity to standards
- Construction and performance according to IEC 60947-5-1
-
Positive opening operation according to IEC 60947
-5-1 Annex K
-
Dimensions conforming to standard DIN 41 636 type F
- Insulation characteristics according to standard IEC 60947-5-1
* Impulse withstand voltage : Uimp = 4 KV
* Rated insulation voltage : Ui = 400 V
* Pollution degree = 3
- Insulation characteristics according to standard EN 50124-1
* Impulse withstand voltage : Uimp = 2.5 KV
* Rated insulation voltage : Ui = 150 V
* Pollution degree = PD3A
Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected
02/11/2015 www.crouzet.com
![](asset-2.png)
Function
Four
-terminal two-way snap-action contact element (form Zb) with positive break operation. The 2 contacts are electrically separated.
Principles
Dimensions (mm)
Product
83240 - 83241 - 83242 - 83243
N
o
Legend
Fixing screw threaded length
Fixing nuts 2 x M3
Dimensions (mm)
Connections
W3 for 6.35 mm x 0,8 mm female connector
Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected
02/11/2015 www.crouzet.com
![](asset-3.png)
Dimensions (mm)
Connections
W3 with 90° angle
Dimensions (mm)
Connections
W5 with screws
Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected
02/11/2015 www.crouzet.com
![](asset-4.png)
4 x M3 screws with saddle
4 x M3 screws with saddle
Dimensions (mm)
Connections
W5 with screws and IP20 protective covers
Dimensions (mm)
Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected
02/11/2015 www.crouzet.com
![](asset-5.png)
Thickness : 1 mm
Thickness : 1 mm
Mounting accessories
Mounting plates with holes
Dimensions (mm)
Mounting accessories
Mounting plates with notches
Dimensions (mm)
Actuators
Roller lever
Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected
02/11/2015 www.crouzet.com
![](asset-6.png)
Thickness : 1 mm
Thickness : 1 mm
Dimensions (mm)
Actuators
Mechanical features of lever versions
Curves
Operating curve for category AC15
Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected
02/11/2015 www.crouzet.com
![](asset-7.png)
* For IP67 versions used in 125 V DC, please consult us.
N
o
Legend
Number of operations
Current in Amps
Curves
Operating curve for category DC13
N
o
Legend
Number of operations
Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected
02/11/2015 www.crouzet.com
![](asset-8.png)
Current in Amps
Product coding 8324 x x x x
How to order
8324
X
xxx (Contact/Force)
0 : Standard/4.5N
1 : Low level/4.5N
2 : Standard/6.5N High force
3 : Low level/6.5N High force
8324x
X
xx (Sealing)
0 : IP 40
2 : IP 67
8324xx
X
x (Connection)
0 : W3 terminals for 6.35 mm female connector
1 : W3 90B terminals with 90° angle for 6.35 mm female connector
2 : W5 terminals with screw
3 : W5 terminals with screw and protective cover
4 : W5 terminals supplied without screws
8324xxxX (Accessory fitted)
0 : Without
1 : Mounting plates with holes
2 : Mounting plates with notches
3 : Roller lever (without plate)
4 : Roller lever with mounting plates with holes
5 : Roller lever with mounting plates with notches
Example : A PBX with Standard contact (AgNi), 6,5 N force, IP 67 sealing, W3 terminals and Roller lever accessory with mounting plates with holes = 83242204
Accessories supplied separately :
79552459 : Mounting plates with holes
79552460 : Mounting plates with notches
79552456 : Roller lever (without plate)
79552457 : Roller lever with mounting plates with holes
79552458 : Roller lever with mounting plates with notches
Product adaptations
Wire outputs, cable outputs
Special levers and actuators
Connections :
- W3 terminals with angle between 0° and 90°
- special add-
on terminals
Special protective cover
UL CSA, CCC, GOST and VDE certification on request
Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected
02/11/2015 www.crouzet.com