Hi-Flo® 3 Automatic Water Softener
Culligan Hi-Flo® 3 Water Softener Standard Features
• Corrosion Resistant Tanks–made from fiberglassreinforced polyester. Additional reinforcement from
continuous fiberglass overwrap. Underdrain design
maximizes softener’s capacity, reduces pressure loss.

• Positive Motor-Driven Regeneration Valve–Motor
driven piston is reliable under severe water conditions,
resists dirt, iron, turbidity.

• Softening Media—High quality resin provides stability
and uniform size for top performance and long life.

• Automatic Brine Control—Automatically measures
the correct amount of brine. A single turn of dial sets
correct amount dosage and capacity.

• Choice of Cycle Controllers—Regeneration cycle may
be initiated by timeclock any or every day of the week.
Optional meter starts cycle after preset volume of
water has been softened.

• Dubl-Safe™ Brine System—Positive overfill protection.
Automatic refill control is backed up by shutoff float
valve to minimize chance of overflow.

The Culligan Hi-Flo® 3 Automatic Water Softener
Applications and Benefits
• RO/DI Pretreatment
• Apartment buildings, assisted living facilities and
hotels—Quality water for laundry, dishwashers,
boilers.
• Office buildings—For heating plant pretreatment,
tenant convenience, general housekeeping.

Options

• Restaurants—For dishwashing, cleaning material
savings, scale reduction.
• Car washes—Quality results, detergent and water
heating savings, scale reduction.
• Light industry—For process and make-up water,
boiler and cooling system pretreatment, general
housekeeping.

Warranty

• Regeneration Flexibility—There are several choices
for regenerating a Hi-Flo® 3 water softener to meet
your requirements. The simple, economical choice
is timeclock operation for both single and duplex
units. If water usage varies, meter operation is
available to signal regeneration immediately or
delay regeneration until a pre-set time. Duplex
meter operated units may be operated in parallel or
on an alternating basis, depending upon your needs.

Culligan® Hi-Flo® 3 water softeners are backed by a
limited 1-year warranty against defects in materials,
workmanship, and corrosion. The plastic conditioner
tank has a 5-year warranty. See printed warranty for
details.*
Some localities have corrosive water. A softener cannot
correct this condition, so its printed warranty disclaims
liability for corrosion of plumbing lines, fixtures, or
water-using equipment. If you suspect corrosion, your
independently operated Culligan dealer has equipment
to control the problem.
*Culligan will provide a copy of warranties upon request.

System Specifications
Pressure:
Vacuum:
Temperature:

30–120 psig
210–830 kPa
None1

HC-150

40–100°F
4 - 38°C

Model

120V, 60 HZ

Turbidity:

5 NTU, max.

Chlorine:

1 mg/L, max.2

Iron:

5 mg/L

2

Tank warranty is void if subject to vacuum
See media specification for details

2

Tank Size***

Peak**

Softener

5

60

78

21 x 54

24 x 48

HC-210

7

58

76

21 x 69

24 x 48

HC-300

10

65

85

24 x 72

30 x 48

HC-450

15

75

100

30 x 72

30 x 48

***Flow rate at a 15 psi pressure loss.
***Flow rate at a 25 psi pressure loss.
***Dimensions are diameter by tank height.

“Hey Culligan Man!”®
SM

TM

1-800-CULLIGAN
©2001 Culligan International Co.
SL-0090 DCO 992824
Printed in USA (2/01)
MOORE PART NO. 46956

Flow Rates
Continuous*

The contaminants or other substances removed or reduced by
this water treatment device are not necessarily in your water.

Culligan Commercial @ Work
www.culligan.com

Pipe
Size

Brine

2″

Electrical:

1

Resin
Qty.
(Ft3)

ISO 9001
Certification

Hey Culligan Man, Culligan Man, Culligan Commercial @ Work, www.culligan.com
and Culligan Service Network are trademarks of Culligan International Company.

HI-FLO 3
®

FULLY AUTOMATIC WATER SOFTENERS
SPECIFICATIONS AND OPERATING DATA
Single
Tank

Exchange Capacity1
@ Salt Dosage

Service Flow Rates2

Peak
Press.
Minimum Maximum Flow Drop
gr @ lb
Model
HC-150

g @ kg

gpm
3

psi

in

ft3

in

in

lb

m /hr

kPa

in

L

mm

mm

kg

78

25

60

15

2

5

21 x 54

24 x 48

540

17.7

172

13.6

103

2

76

25

58

15

2

17.2

172

13.2

103

2

198 530 x 1,750 610 x 1,200

290

85

25

65

15

2

10

865

19.3

172

14.7

103

2

284 410 x 1,830 760 x 1,200

300,000/90 450,000/225

100

25

75

15

2

15

19,440/41 29,160/102

22.7

172

17.0

103

2

426 760 x 1,830 760 x 1,200

100,000/30 150,000/75
9,720/34

140,000/42 210,000/105
13,600/48

200,000/60 300,000/150
12,960/27

HC-450

3

psi

Approx.
Ship.
Weight

kPa

9,070/19
HC-300

g @ kg

gpm

Brine
Tank
Size

m /hr

6,480/14
HC-210

gr @ lb

Continuous
Softener
Press. Pipe Resin
Tank
Flow Drop Size Qty.
Size

19,400/68

142 530 x 1,370 610 x 1,200
7

21 x 69

24 x 72

30 x 72

24 x 48

30 x 48

30 x 48

460
640

395
1,250
570

1 Exchange capacities based on treating water containing 10 grains per gallon (171 mg/L) of hardness (expressed as calcium carbonate), free of color, oil, turbidity
and at a service flow rates not exceeding 20 gpm per square foot (49 m3/m2/min) of bed area. These are nominal capacities and will vary with influent water
characteristics, temperature, pressure and other factors.
2 Operation of a softener at peak flow rate for extended periods of time may result in a slight reduction of softening capacity. This is due to premature hardness
breakthrough.
NOTE: Operational, maintenance and replacement requirements are essential for this product to perform as advertised.
Specifications are shown for single models. Duplex models have two softener tanks and one brine tank system.

Commercial Systems
©2000 Culligan
1-800-CULLIGAN
www.culligan.com
Printed in USA 4/00
DCO 992587
SL-0074
Moore Part No. 46944

Hi-Flo 3

CAD File: Soft_HF3.dwg

More

ENGINEER’S SPECIFICATION
AUTOMATIC WATER SOFTENER
HI-FLO® 3
1.0
1.1

1.2

1.2

2.0
2.1

CUSTOMER:
DATE:

SCOPE
Provide as indicated a vertical pressure type water softener system complete with pressure vessel, softening
resin, control valve, brine maker and controller. The system will be of an approved design as fabricated by a
manufacturer regularly engaged in the production of water treatment equipment. All equipment and material will
be supplied in compliance with the specifications as intended for a complete and operational system.
¨ (Open Bidding Arrangement)
Qualified manufacturers of water treatment equipment of the type specified are Culligan International Company
or the Engineer’s approved equal.
¨ (Closed Bidding Arrangement)
Qualified manufacturers of water softener equipment must be engaged in the manufacture of this equipment for
a period of not less than fifteen (15) years. Acceptable manufacturers are Culligan International Company or the
Engineer’s approved equal.
GENERAL DESCRIPTION
¨ (Selection for statement of specific model)
The system specifications are based on Culligan International model ________________________________.
The purpose of the Culligan International Series Hi-Flo® 3 automatic water softener will be to remove mineral
hardness from a known water supply to a level not to exceed ________ mg/l, as determined by an accepted
ASTM or EDTA test method, when the system is operated at ________ gpm and in accordance with the
operating instructions. The system will be capable of supplying ________ gallons of softened water between
regenerations based on the influent water analysis listed in Section 3.1 of this equipment specification.
The systems performance is rated at a design flow rate of ______ gpm with a rated pressure drop of ______
psi, and will be capable of a peak flow rate of ______ gpm for sustained periods of 90 minutes with a pressure
drop of ______ psi.
There shall be a quantity of ________ of the above described systems.

2.1

¨ (Selection for general statement)
The system, in compliance with the equipment specification, is described as an automatic _______________
water softener system meeting the performance and design data requirements as hereinafter specified.

3.0

PERFORMANCE AND DESIGN DATA

3.1

INFLUENT WATER ANALYSIS
Calcium, Ca:
Magnesium, Mg:
Total Hardness:
(Constituents above are expressed in ppm or mg/l as CaCO3 or as otherwise specified.)
Iron, Fe:
Manganese, Mn:
Total Dissolved Solids, TDS:
(Constituents above are expressed in ppm or mg/l.)
Turbidity, NTU:
Color:
pH:

More
3.2

DESIGN PARAMETERS
Normal System Flow & Pressure Drop:
gpm @ 15 PSI
Maximum System Flow & Pressure Drop:
gpm @ 25 PSI
Backwash/Rinse Flow:
gpm
Backwash Volume:
gallons nominal
Daily Water Usage:
gallons per day (gpd)
Daily Hours of Water Demand:
Operating Temperature Range:
40°–100°F
Operating Pressure Range (System):
30–120 PSI
Electrical Requirements:
120 Volt, 60 Hz, 1 phase (receptacle required)
”W x
”H
System Dimension (L x W x H):
”L x

3.3

¨ (ASTM soap test method)
EFFLUENT WATER QUALITY

3.3

¨ (Hardness EDTA test method)
EFFLUENT WATER QUALITY

4.0

EQUIPMENT SPECIFICATIONS

4.1

SOFTENER TANK(S)
Each system shall include _____ tank(s). Each softener tank shall be _____ inches in diameter. The sideshell
height shall be _____ inches, sufficient to allow for proper freeboard space above the resin bed for adequate
expansion of the resin during backwashing.

ZERO GPG HARDNESS

MG/L HARDNESS

4.1.0 Tank Construction
Tank(s) shall be manufactured of polyester reinforced by a continuous roving glass filament overwrap. The top
opening will be 4”-8 UN threaded and the tank bottom will be supported on a molded structural base.
4.2

INTERNAL DISTRIBUTION

4.2.1 The upper distribution system shall be of the single point diffuser type to dispense water laterally to avoid
channeling within the resin bed.
4.2.2 The lower distribution system shall be of the single point distributor type, constructed of PVC pipe and a fine
slotted strainer to provide even flow distribution through the resin bed. The distribution system shall be
embedded in a subfill of washed inorganic material to support the resin bed.
4.3

MAIN OPERATING VALVE
The main operating valve shall be of a top mount design constructed of all brass and sized with 2 inch NPTI
inlet and outlet connections.
The main operating valve will be of the motor driven, mechanically activated design with four (4) positions to
accomplish the regeneration steps of backwash, brine draw/rinse and fast rinse/brine refill, in addition to the
service position.
The main operating valve shall incorporate self adjusting flow regulators to control the rate of flow and prevent
resin loss during backwash regardless of system pressure fluctuations between 30 and 120 psi.
The main operating valve will be fitted with a fixed orifice eductor.
¨ (Single units only – hard water bypass)
The unit shall be supplied so that the valve will allow automatic bypass of untreated water during regeneration.
The bypass shall be integral to the main operating valve body and be capable of being easily modified to
prevent hard water bypass.
¨ (Single units only – NO hard water bypass)
Culligan Hi-Flo® 3 Softener Engineer’s Specification

Page 2

More
The unit shall be supplied so that the valve will not allow automatic bypass of untreated water during
regeneration. The bypass shall be integral to the main operating valve body and be capable of being easily
modified to allow hard water bypass.
4.4

CONTROLS
The main operating valve will be controlled by an integral clock timer.
The controller shall sequence all steps of an automatic regeneration and automatically return the softener to a
service or stand-by mode.
The controller shall allow for a manual initiation of the automatic regeneration sequence by utilizing a manual
regeneration knob on the timer.

4.4.1 System control options
¨ (Time Clock, Single Unit)
A time-initiated regeneration for single units shall be available. The clock timer will be capable of regenerating
the softener at any time of day or night and on any or every day of the week. The timer will activate a motor
drive that will perform the regeneration functions on the exhausted tank and return it to service.
¨ (Meter Initiated Delayed, Single Unit)
A volumetric meter, mechanically coupled to the timer control, shall set the timer for regeneration at a preset
time of day or night after the preset volume of water has passed through the water softener. The timer will
activate a motor drive that will perform the regeneration functions on the exhausted tank and return it to the
service position.
¨ (Time Clock, Parallel Twin Unit)
A time-initiated regeneration for parallel twin units shall be available. Each clock timer will be capable of
regenerating the softener at any time of day or night and on any or every day of the week. The timer will
activate a motor drive that will perform the regeneration functions on the exhausted tank and return it to service.
Simultaneous regenerations shall not be possible.
¨ (Meter Initiated, Parallel Twin Unit)
Each unit shall include a volumetric meter, mechanically coupled to the timer control. Upon exhaustion of either
tank, its control shall activate a motor drive that will immediately, or at a preset time of day or night, perform the
regeneration functions on the exhausted tank and return it to the service position. The controls shall include an
electrical interlock to prevent simultaneous regeneration of both softeners in the event the second tank
exhausts while the first tank is in regeneration.
¨ (Meter Initiated, Alternating Twin Unit)
A single, remote mounted volumetric meter shall signal the softeners to regenerate on an alternating basis after
the preset volume of water has passed through the water softener. One unit remains in a fully regenerated
stand-by condition while the other unit is in service. Upon exhaustion of the service unit, the stand-by unit shall
immediately be placed into service and the exhausted unit shall be removed from service and the regeneration
initiated. The timer will activate a motor drive that will perform the regeneration functions on the exhausted tank
and return it to the stand-by position. No external alternating devices will be acceptable. The alternating function
must be contained in the sequencing controller and each controller must communicate via a single pre-wired
cable assembly, simultaneous regenerations shall not be possible.
¨ (Meter Initiated systems ONLY)
4.4.2 Flow Meter(s)
¨ (Meter Initiated single and parallel systems ONLY)
A flow meter package shall be provided consisting of a mechanical turbine-type meter; the package shall
include a total of _____ meter assemblies.
The meter provided shall be 2.0 inches, compatible with the specified piping. It will be designed to allow ease of
removal of the turbine for inspection without modification of the piping system. A cable shall be provided for
direct connection to the operating valve.
The meter package provided shall be functional within the flow range of 3 to 130 gpm and will be provided with
a threaded tee meter fitting.
Culligan Hi-Flo® 3 Softener Engineer’s Specification

Page 3

¨ (Meter Initiated alternating system ONLY)
One remote mounted mechanical turbine-type meter will be provided.
The meter provided shall be 2.0 inches, compatible with the specified piping. It will be designed to allow ease of
removal of the turbine for inspection without modification of the piping system. The meter will be electrically
connected to the cycle timer.
The meter provided shall be functional within the flow range of 3 to 130 gpm and will be provided with a
threaded tee meter fitting.
4.5

EXCHANGE RESIN
The ion exchange resin shall be virgin high capacity “standard mesh” of sulfonated polystyrene type stable over
the entire pH range with good resistance to bead fracture from attrition or osmotic shock. Each cubic foot of
resin will be capable of removing 30,000 grains of hardness as calcium carbonate when regenerated with 15
lbs. of salt. The resin shall be solid, of the proper particle size of 20-50 mesh, U.S. standard screen and will
contain no agglomerates, shells, plates or other shapes that might interfere with the normal function of the water
softener. The resin shall be manufactured to comply with the food additive regulation 21 CFR 173.25 as set
forth by the USFDA.
The system shall include _____ cubic feet of exchange resin per vessel and a total of _____ cubic feet of resin
for the system.

4.6

BRINE SYSTEM
Provide a complete brine system consisting of a plastic tank, salt platform, brine well, an automatic brine valve
and all necessary fittings for operation with the water softening system. The system shall consist of a combined
brine measuring and salt storage tank with salt platform. The tank will be sized ____ inches x _____ inches; the
system will include a total of _____ brine tank(s).
The brine tank will be equipped with a float operated non-corrosive field serviceable brine float valve for
automatic control of brine withdrawal and fresh water refill.
The brine valve will automatically open to admit brine to the resin tank during eduction and close automatically
providing positive shut-off to prevent air from entering the system. The brine valve will also regulate the flow of
soft water into the brine tank during refill. The brine valve works with the timed fill feature of the main operating
valve controls to admit the correct volume of fresh water to the brine tank in accordance with the salt dosage
setting on the controls. The brine valve will include a float operated safety shut-off valve as a back up to the
timed refill from the main operating valve control to prevent brine tank overflow.

4.7
4.7.1
4.7.2
4.7.3
4.7.4

ACCESSORIES
(All Optional selections)
¨ Water test kits for hardness tests will be supplied.
¨ Pressure Gauges for hard water inlet and soft water outlet.
¨ Sampling Cocks for hard water inlet.
¨ Vacuum Breaker for protecting Fiberglass tanks from vacuum.

5.0

INSTRUCTIONS
_____ complete sets of installation, operating and maintenance manuals shall be provided.

6.0

FIELD SERVICE
The services of a factory authorized service representative can be made available to supervise, inspect and
provide operator training as required for initial start-up and system operation. Contact your local Culligan dealer
for service rates and scheduling.

7.0

WARRANTY
A single written warranty must be provided from the manufacturer of the water softener system covering
workmanship and materials.

Rev. 11/00

Culligan Hi-Flo® 3 Softener Engineer’s Specification

Page 4



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : Yes
Modify Date                     : 2002:02:21 07:21:34-06:00
Create Date                     : 2000:08:08 13:15:01-05:00
Subject                         : Fall 2000
Page Count                      : 9
Has XFA                         : No
Page Mode                       : UseOutlines
Page Layout                     : SinglePage
Mod Date                        : 2002:02:06 13:52:02-06:00
Creation Date                   : 2000:08:08 13:15:01-05:00
Author                          : KSR
Producer                        : Acrobat PDFWriter 3.02 for Windows
Metadata Date                   : 2002:02:06 13:52:02-06:00
Title                           : Hi-Flo 3 Softeners
Description                     : Fall 2000
Creator                         : KSR
EXIF Metadata provided by EXIF.tools

Navigation menu