Cyberpower 1200E Users Manual (SAVE THESE INSTRUCTIONS)
2200E to the manual 9bc93b93-4371-4498-af65-59559c7acaf7
2015-02-05
: Cyberpower Cyberpower-1200E-Users-Manual-529983 cyberpower-1200e-users-manual-529983 cyberpower pdf
Open the PDF directly: View PDF .
Page Count: 2
Download | |
Open PDF In Browser | View PDF |
1200E/1500E/2200E User’s Manual 3. Charge the Battery Your new UPS may be used immediately upon receipt. However charge loss may occur during shipping and storage. So charging the battery for at least 8 hours is recommended to insure that the battery is fully charged. (To recharge the battery, simply leave the unit plugged into an AC outlet.) This UPS can be charged even when UPS is not turn on. 4. Connect to AC Use German power cord to connect the UPS to a wall outlet. Please avoid using extension cords and adapter plugs. (To maintain optimal battery charge, leave the UPS plugged in at all times.) 5. Connect the Load Connect the equipment to your UPS outlets. The IEC power cord coming with the unit are used to connect your computer and monitor to the UPS. Items such as copiers, laser printers, vacuums, space heaters, or other large electrical devices SHOULD NOT be connected to the UPS. Please make sure that the total loads of your equipments are less than the maximum total power load of your UPS. 6. Connect to Computer: Install your software and accessories. To use the software, simply use the enclosed serial interface or USB cable to connect the UPS unit and your computer. K01-0000032-01 SAFETY WARNINGS BASIC OPERATION (SAVE THESE INSTRUCTIONS) This manual contains important safety instructions. Please read and follow all instructions carefully during installation and operation of the unit. Read this manual thoroughly before attempting to unpack, install, or operate your UPS. FRONT PANEL DESCRIPTION This equipment can be operated by any individuals with no previous training. The socket-outlet shall be installed near the equipment and easily accessible. During the installation of this equipment it should be assured that the sum of the leakage currents of the UPS and the connected loads does not exceed 3.5mA. Attention, hazardous through electric shock. Also with disconnection of this unit from the mains, hazardous voltage still may be accessible through supply from battery. The battery supply should be therefore disconnected in the plus and minus pole at the quick connectors of the battery when maintenance or service work inside the UPS is necessary. 1. Power Switch Press the power switch to turn the UPS ON or OFF. Do not dispose of batteries in a fire, the battery may explode. Do not open or mutilate the battery or batteries, released electrolyte is harmful to the skin and eyes. 2. LCD Function Selected Switch The switch can be used to select the LCD display contents Including input/output voltage and estimated run time, etc. INSTALLING YOUR UPS SYSTEM REAR PANEL DESCRIPTION UNPACKING Inspect the UPS upon receipt. The box should contain the following: UPS Unit¯1; IEC Power Cord¯1;USB Cable¯1;User Manual¯1; Management software Disk¯1 HOW TO DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT 1. Insure that the equipment plugged into the battery power-supplied outlets does not exceed the UPS unit’s rated capacity (1200VA/720W for Value 1200E, 1500VA/900W for Value 1500E, 2200VA/1320W for Value 2200E). If rated unit capacities are exceeded, an overload condition may occur and cause the UPS unit to shut down or the fuse blow. 2. If the power requirements of your equipment are listed in units other than Volt-Amps (VA), convert Watts (W) or Amps (A) into VA by doing the calculations below. Note: The below equation only calculates the maximum amount of VA that the equipment can use, not what is typically used by the equipment at any one time. Users should expect usage requirements to be approximately 60% of below value. TO ESTIMATE POWER REQUIREMENTS 1. Watts (W) x 1.67 = VA or Amps (A) x 230 = 1. AC Inlet Connect to utility power through the input power cord 2. Input Circuit Breaker The circuit breaker provides optimal overload protection. 3. AC outlet The UPS provides 6 outlets for connected equipment to insure temporary uninterrupted operation during a power failure and against surges and spikes. 4. Serial Port to PC This port allows connection and communicates from the DB-9 serial on the computer to the UPS unit. The UPS communicates its status to ® the PowerPanel Personal Edition software. This interface is also compatible with the UPS service provided by Windows 98, Windows ME, Windows NT, Windows 2000, Windows XP, Windows Server 2003, Windows Vista. 5. USB Port to PC This port allows connection and communication from the USB port on the computer to the UPS unit. The UPS communicates its status to the ® PowerPanel Personal Edition software. This interface is also compatible with the UPS service provided by Windows 98, Windows ME, Windows NT, Windows 2000, Windows XP, Windows Server 2003, Windows Vista. VA 2. Add the totals up for all pieces of equipment and multiply this total by 0.6 to calculate actual requirements. There are many factors that can affect the amount of power that your computer system will require. The total load that you will be placing on the battery-powered outlets should not exceed 80% of the unit’s capacity. HARDWARE INSTALLATION GUIDE Before installation, please read and understand the following instructions: 1. Placement The UPS must be installed in a protected environment away from heat- emitting appliances such as a radiator or heat register. Do not install this product where excessive moisture is present. NOTE: Only one of these two ports can be used as communication and control of the UPS unit at one time. 2. Ventilation The location should provide adequate air flow around the UPS with one inch minimum clearance on all sides for proper ventilation. 6. Communication Protection Ports RJ11/RJ45 Communication protection ports will protect any standard modem, fax, telephone line, or network cable. Functional Test TECHNICAL SPECIFICATIONS AC Mode The UPS delivers power to the loads derived from the utility and maintains proper battery charge. It also regulates the output voltage to within a narrow range. On-Battery Mode The UPS operates on battery when the line voltage or frequency has fallen outside the limits. Local users are alerted to this mode of operation by visual and audible indicators. The UPS provides power to the load from the battery and through its inverter and the output voltage and frequency of the UPS are regulated within a narrow range 1. Switch On Press the power switch on the front panel then the status LCD will light up. 2. Switch Off Press again the power switch, the status LCD on the front panel will go off. 3. Cold Start / Start on Battery: This UPS can be turned on even when AC is not present. Press the power switch on the front panel then the status LCD will light up. ROUTINE MAINTENANCE AND STORAGE ROUTINE MAINTENANCE 1. Use dry soft clothes to clean the front panel and plastic parts. Do not use any detergent that contains alcoholic ingredient. 2. The expected lifetime of the battery is around 3 years. Improper operation and harsh environment will reduce the actual lifetime. 3. Unplug the UPS from power inlet if the UPS will not operate for long period of time. STORAGE 1. First turn off your UPS and disconnect its power cord from the wall outlet. Disconnect all cables connected the UPS to avoid battery drain. 2. The UPS should be stored in a cool dry location. 3. Make sure the battery is fully charged before the UPS is stored. 4. For extended storage in moderate climates, the battery should be charged for 12 hours every 3 months by plugging the power cord into the wall receptacle and turning on the main switch. Repeat it every 2 months in high temperature locations. Model Capacity (VA) Capacity (Watts) Input Input Voltage Range Frequency Range Output On Battery Output Voltage On Battery Output Frequency Overload Protection Physical Total # of UPS Receptacles Maximum Dimensions Weight Battery Sealed Maintenance Free Lead Acid Battery Typical Recharge Time Warning Diagnostics Indicators Audible Alarms Environmental Operating Temperature Operating Relative Humidity Communication ® PowerPanel Personal Edition Software Management Auto-Charger Auto-Restart USB Value 1200E 1200VA 720W Value 1500E 1500VA 900W Value 2200E 2200VA 1320W 160VAC~270VAC 50/60Hz +/-3Hz(Auto Sensing) Simulated Sine Wave at 230Vac +/-7% 50/60 Hz On Utility: Circuit Breaker, On Battery: Internal Current Limiting (6) IEC 320 C13 32.6cm(L) × 14.cm(W) × 18cm(H) 13.0 kg / 28.6 Lbs 14.3 kg / 31.5 Lbs 15.4 kg / 33.9 Lbs 12V / 7Ah x2 12V / 8.5Ah x2 12V / 9Ah x2 8 Hours Power On, UPS Status Display, Capacity Display, Digital Value Display On Battery, Low Battery, Overload +32°F to 104°F ( 0°C to 40°C ) 0 to 95% NON-CONDENSING Windows 98/ME/2000/NT/XP/Vista Yes Yes Yes DEFINITIONS FOR ILLUMINATED LCD INDICATORS LCD Indication TROUBLE SHOOTING Line mode Problem The UPS does not perform expected runtime. The UPS will not turn on. Outlets do not provide power to equipment Possible Cause Batteries are not fully charged. Recharge the battery by leaving the UPS plugged in. Battery is slightly worn out. Contact CyberPower Systems at service@cyberpower-eu.com The on/off switch is designed to prevent damage by rapidly turning it off and on. The unit is not connected to an AC outlet. Turn the UPS off. Wait 10 seconds and then turn the UPS on. UPS Status Display Capacity Display Digital Value Display Select SW Load Cap. Battery Cap. V V V V V V X X X X X X ------- X X X X X X V V V X V V X X X V X X V X V X -- -- -- -- -- Press Initial 1st 2nd 3rd 4th 5th(Return) Press >3sec (Sound Disable) Input Voltage Output Voltage Run Time % of Load % of Batt. V V V V V V -- -- The unit must be connected to a 220-240V 50/60Hz outlet. Press >3sec again (Sound Enable) V X X X -- -- -- -- -- -- -- V X -- V -- -- -- -- -- -- -- The battery is worn out. Contact CyberPower Systems at service@cyberpower-eu.com (Overload) “V” : Illuminated, Mechanical problem. Contact CyberPower Systems at service@cyberpower-eu.com Battery mode Circuit breaker is tripped due to overload Turn the UPS off and unplug at least one piece connected equipment. Unplug the power cord of the UPS then press the circuit breaker knob. Input Voltage Output Voltage % of Load % of Batt. Batteries are discharged Allow the unit to recharge for at least 4 hours. Unit has been damaged by a surge or spike. The serial/USB cable is not connected. PowerPanel® Personal Edition is inactive (all icons are gray). Solution Contact CyberPower Systems at service@cyberpower-eu.com Connect the serial/USB cable to the UPS unit and an open serial port on the back of the computer. You must use the cable that came with the unit. “X” : Not Illuminated, “--“ : Either UPS Status Display Capacity Display Digital Value Display Select SW Press Initial 1st 2nd 3rd 4th 5th(Return) Press >3sec (Sound Disable) Press >3sec again (Sound Enable) (Overload) “V” : Illuminated, Load Cap. Battery Cap. Run Time X X X X X X V V V V V V ------- X X X X X X X X V X X X V V X V V V X V V X -- -- -- -- -- -- -- X V X X -- -- -- -- -- -- -- X V -- V -- -- -- -- -- -- -- “X” : Not Illuminated, V V V V V V “--“ : Either The serial/USB cable is connected to the wrong port. Try another serial/USB port of your computer. The unit is not providing battery power. Shutdown your computer and turn the UPS off. Wait 10 seconds and turn the UPS back on. This should reset the unit. CyberPower Systems B.V. The serial cable is not the cable that was provided with the unit. You must use the cable included with the unit for the software. Tel: +31 40 2348170, E-MAIL: sales@cyberpower-eu.com For more information, visit eu.cyberpowersystems.com or contact Flight Forum 3545 5657DW Eindhoven The Netherlands CyberPower Systems Inc. (USA) 4241 12th Avenue East, Suite 400, Shakopee, MN 55379, U.S.A. Tel: +1 952 4039500, Fax: +1 952 4030009, E-MAIL: sales@cyberpowersystems.com CyberPower warrants to you, the original purchaser, that CyberPower UPS will be free from defects in design, assembly, materials and workmanship for two years ( battery is only one year) from the date of original purchase. Any warranty services, please contact your local dealers or distributors. Entire contents copyright ©2004 CyberPower Systems B.V., All rights reserved. Reproduction in whole ® ® or in part without permission is prohibited. PowerPanel and PowerPanel Plus are trademarks of CyberPower Systems (USA) Inc.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Tagged PDF : Yes XMP Toolkit : 3.1-701 Producer : Acrobat Distiller 7.0.5 (Windows) Source Modified : D:20071029023033 Creator Tool : Acrobat PDFMaker 7.0.7 for Word Modify Date : 2007:10:29 17:31:05+08:00 Create Date : 2007:10:29 17:29:09+08:00 Metadata Date : 2007:10:29 17:31:05+08:00 Document ID : uuid:c4ec5928-c03f-48a9-ae5c-b16e514128cd Instance ID : uuid:1ceef588-b6fb-4960-acde-99e4bcd9abb6 Version ID : 21 Format : application/pdf Title : (SAVE THESE INSTRUCTIONS) Creator : Faith Subject : Headline : Page Count : 2 Page Layout : OneColumn Author : FaithEXIF Metadata provided by EXIF.tools