Cyberpower K01 0000083 00 Users Manual Cover
K01-0000083-00 to the manual 3e3f0daf-22f6-40d7-8ce7-dd0f268533cd
2015-01-23
: Cyberpower Cyberpower-K01-0000083-00-Users-Manual-221227 cyberpower-k01-0000083-00-users-manual-221227 cyberpower pdf
Open the PDF directly: View PDF .
Page Count: 10
Download | |
Open PDF In Browser | View PDF |
User Manual Power Distribution Unit 4241 12th Ave E #400, Shakopee, MN 55379 1-877-297-6937 www.CPSww.com K01-0000083-00 Table of Contents Model List ......................................................1 PDU Naming Convention ............................. 1 Package Contents ........................................ 2 Safety Precautions ....................................... 2 Installation .................................................... 3 Horizontal Installation ....................... 3 Vertical Installation with Brackets ... 4 Vertical Installation Keyhole Mounts (0U models only) ... 5 Cord Retention Tray installation ...... 5 Meter Configuration .......................... 5 Electrical Installation ........................ 6 Troubleshooting ........................................... 6 Product Features Technical Specification ............................... 7 Basic Series (1U 20A)......................... 7 Basic Series (1U 30A)......................... 8 Basic Series (0U 10A)......................... 9 Basic Series (0U 20A)........................ 10 Basic Series (0U 30A)........................ 11 Metered Series (0U 20A) .................... 12 Metered Series (0U 30A) .................... 13 Warranty & Service .......................................14 Model List: Package Contents Basic Series: PDU20BHVT8R PDU20BHVT10R PDU20BHVT12R PDU20BHVIEC8R PDU20BHVIEC10R PDU20BHVIEC12R PDU20BHVIEC12Ra PDU30BT8F8R PDU30BT10F10R PDU30BHVT8R PDU30BHVT10R PDU30BHVT12R Basic Series (0U): PDU (1) Cord Retention Tray (1/2/3/4 pcs - varies by model) Mounting Brackets PDU10BVHVIEC16F PDU10BVHVIEC20F PDU20BVHVT16F PDU20BVHVT20F PDU20BVHVT24F PDU20BVHVT32F PDU20BVHVT38F PDU20BVHVIEC16F PDU20BVHVIEC20F PDU20BVHVIEC24F PDU20BVHVIEC32F PDU20BVHVIEC38F PDU30BVT14F PDU30BVT16F PDU30BVT20F PDU30BVT28F PDU30BVT32F PDU30BVHVT16F PDU30BVHVT20F PDU30BVHVT32F PDU30BVHVT38F Horizontal Installation Used (1 set) Vertical Installation Vertical Mounting Brackets (1 set) Used (1 set) (for 0U models only) Cord Retention Tray Mounting Screws M3 X 6 (4/8/12/16 pcs - varies by model) Bracket Mounting Screws M4 X 8 (4pcs) Metered Series (0U): PDU20MVHVT20F PDU20MVHVT30F PDU20MVHVT38F PDU20MVHVIEC24F PDU20MVHVIEC30F PDU20MVHVIEC38F PDU30MVT24F PDU30MVT32F PDU30MVHVT20F PDU30MVHVT30F PDU30MVHVT38F Keyhole Mounting Pegs (2pcs) with Screws M4 X 8 (2pcs) (for 0U models only) Cord Retainer Clips (8/10/12/14/16/ 20/24/30/32/38 pcs - varies by model) for Cord Retention Tray Ground Screw M5 X 6 (1 pcs) PDU Naming Convention: Documentation: PDU XX M V HV T F R NET 1 2 3 4 5 6 7 Use r Man ual Dist Power ribu tion Unit 8 User Manual Amperage – 15A, 20A, 30A B: =Basic M: =Metered SW: = Switched NULL: =Horizontal V:= Vertical 3. Rack Space: NULL: =120V HV:= High Voltage – 200V to 230V 4. Input Voltage: NULL: =NEMA 5-15P / 5-20P 5. Plug Type: T: = Twist (NEMA L5-L6 Plug) IEC:= (IEC C14/C20) Number of Outlets followed by F – Example 8F 6. Outlet Number Front Number of Outlets followed by R – Example 8R 7. Outlet Number Rear 8. Network Management NET 1. Amperage: 2. Series: Check Product Registration Card Product Registration Card Before using, please check to ensure the package contains all the items shown above. If there are missing parts please contact CyberPower technical support at www.CPSww.com or call 1-877297-6937. Safety Precautions Read the following before installing or operating the Power Distribution Unit (PDU): 1. Use only the supplied hardware to attach the mounting brackets. 2. The PDU must only be plugged into a three-wire, grounded outlet on a circuit protected by a fuse or circuit breaker. Connection to any other type of power outlet may result in a shock hazard. 3. Do not use extension cords or adapters with this PDU. 4. Never install a PDU, or associated wiring or equipment, during a lightning storm. 5. Check that the power cord, plug, and socket are in good condition. 6. The socket-outlet shall be installed near the equipment and shall be easily accessible. 7. CAUTION! To prevent the risk of fire or electric shock, this PDU should be installed in a temperature and humidity controlled indoor area free of conductive contaminants. Do not install this PDU where excessive moisture or heat is present.. 1 For information on Cyberpower products, visit www.CPSww.com For information on Cyberpower products, visit www.CPSww.com 2 Installation Vertical Installation with Brackets Horizontal Installation (1U models only) Step 1 – Mounting bracket installation Step 1 – Mounting bracket installation Install the screws (M4 X 8) in holes diagonal from each other. Install the screws (M4 X 8) in holes diagonal from each other. Step 2 – PDU Mounting Step 2 – PDU Mounting Install the PDU using fasteners compatible with the rack. Vertical Installation with Brackets (0U models only) Step 1 – Mounting bracket installation Install the PDU using fasteners compatible with the rack. Attach the Vertical Mounting Brackets to the PDU with the 4 supplied Bracket Mounting Screws (M4 X 8). Step 2 – PDU Mounting Install the PDU using fasteners compatible with the rack. 3 For information on Cyberpower products, visit www.CPSww.com For information on Cyberpower products, visit www.CPSww.com 4 Vertical Installation with Keyhole Mounts (0U Models) Electrical Installation Step 1 – Keyhole Mount installation Step 1 – Receptacle evaluation Ensure that the plug type of your PDU unit (e.g. NEMA 5-15P, NEMA 520P, NEMA L5-30P) matches the wall receptacle type that you are using. CAUTION!! PDU must be plugged into a three-wire, grounded wall receptacle only. The wall receptacle must also be connected to an appropriate branch circuit/main with fuse or circuit breaker protection. Connection to any other type of wall receptacle may result in a shock hazard. Step 2 – Plug the PDU into the wall receptacle Attach the Keyhole Mounting Pegs to the PDU with the 2 supplied Bracket Mounting Screws (M4 X 8). Step 2 – PDU Mounting Step 3 – Attach equipment Before attaching equipment, it is important to calculate the total load that you will be placing on the PDU. It is extremely important not to exceed the PDU's maximum current load (as outlined in the Specifications section). In order to determine your total load, simply add up the amperage of your devices and ensure that it does not exceed the unit’s capacity. Align the the Keyhole Mounts to the Keyhole Slots on the rack. Insert and slide down to lock firmly into place. Cord Retention Tray installation (Optional for both horizontal and vertical installations) Attach the Cord Retention Tray to the PDU with the 4 supplied Cord Retention Tray Mounting Screws (M3 X 6). Troubleshooting Problem Possible Cause PDU Outlets do not 1. Open breaker provide power to 2. Loose power cord connected equipment Amperage displayed 1. Overload on Amperage Meter 2. Amperage meter is damaged exceeds the unit’s capability (Metered type only) Circuit breaker has tripped 1. Sustained overload 2. Excessive ambient or internal temperatures. 3. Faulty breaker Solution Reset Breaker check if plug is completely connected. If the problem remains contact tech support. The meter will flash when overloaded. Reduce the load on the PDU until the overload is gone. If the problem remains contact tech support. Reset Breaker. If the problem remains contact tech support. Attach the Cord Retainer Clips to the Cord Retention Tray. Meter Configuration ! Note Depending on installation method (vertical or horizontal), the LED Meter may need to be rotated, before installation, for proper orientation. Use a screwdriver to gently remove the LED Meter. Rotate the LED Meter 90 degrees, and insert back into the PDU. 5 For information on Cyberpower products, visit www.CPSww.com For information on Cyberpower products, visit www.CPSww.com 6 Basic Series ( 1U 20A ) Basic Series ( 1U 30A ) Product Features Product Features Front View Front View Normal Type R R BANK1 BANK2 BANK1 A A A. Mounting Bracket B C A. Mounting Bracket Back View B. LED Indicators C. Front Bank 1 Outlets High Voltage Type Twist Type R BANK1 BANK2 A B A. Mounting Bracket A G B C A. Mounting Bracket B. Rear Outlets (IEC 320 C13) C. Rear Outlets (IEC 320 C19) D. Circuit Breaker D E F G B. LED Indicators Back View Normal Type E. External Site Ground F. AC Power Cord G. Cord Retention Tray Screw Holes BANK2 A IEC Type G B C D E F G A.Mounting Bracket B.Circuit Breaker (Bank 1) C.Rear Bank 2 Outlets D.External Site Ground E.Circuit Breaker (Bank 2) F.AC Power Cord G.Cord Retention Tray Screw Holes High Voltage Type BANK2 A F B C D E D. External Site Ground E. AC Inlet (IEC 320 C20) F. Cord Retention Tray Screw Holes A. Mounting Bracket B. Rear Outlets (IEC 320 C13) C. Circuit Breaker Technical Specifications Model Name A H B C D PDU20BHVIEC8R PDU20BHVIEC10R PDU20BHVIEC12R PDU20BHVIEC12Ra PDU20BHVT8R PDU20BHVT10R PDU20BHVT12R Model Name Voltage 100 ~ 125 V 200~230V Max Current 30 A Regulatory Derated Input Current 16 A Regulatory Derated Input Current 24A 16 A Circuit Breaker Circuit Breaker NEMA L6-20P IEC 320 C20 10 f t Power Cord Length Plug Type Power Cord Length Output 200~230V 20 A IEC 320 C13(8) IEC 320 C13(10) IEC 320 C13(12) IEC 320 C19(2)/C13(10) IEC 320 C19(2)/C13(6) IEC 320 C19(2)/C13(8) IEC 320 C13(12) Voltage Outlet Type(Quantity) N/A LED Indicators Meter Readout N/A Meter Readout 17.5" x 1.5" x 1.75" / 44.5 x 3.81 x 4.45 cm Environmental Warranty 100~125 V 200~230V 30 A IEC 320 C19(2)/C13(6) IEC 320 C19(2)/C13(8) IEC 320 C13(12) NEMA 5-20R(16) NEMA 5-20R(20) Bank1(GREEN) Bank2(GREEN) N/A Dimension (WxDxH) 17.5"x2.25"x1.75" / 44.5x5.72x4.45 cm 17.5"x1.5"x1.75" / 44.5x3.81x4.45 cm Environmental Operating 0 to 95% Non-condensing Non-Operating 0 to 95% Non-condensing Operating 0ft to 10,000ft Non-Operating 0ft to 50,000ft Operating 32F to 95F Non-Operating 5F to 113F Safety Approvals Certifications 10 f t Physical Physical Temperature 12 f t Indicators LED Indicators Altitude 16 A x 2 NEMA L6-30P Max Current Indicators Humidity 20 A x 2 NEMA L5-30P Output Max Current Dimension (WxDxH) H PDU30BHVT8R PDU30BHVT10R PDU30BHVT12R PDU30BT8F8R PDU30BT10F10R 20 A Outlet Type(Quantity) G A.Mounting Bracket B.Bank 2 Outlets C.Bank 1 Outlets D.Circuit Breaker (Bank 2) E.Circuit Breaker (Bank 1) F.External Site Ground G.AC Power Cord H.Cord Retention Tray Screw Holes Max Current Voltage F Input 200~230V Voltage Plug Type E Technical Specifications Input 7 BANK1 F Humidity Altitude Temperature Operating 0 to 95% Non-condensing Non-Operating 0 to 95% Non-condensing Operating 0ft to 10,000ft Non-Operating 0ft to 50,000ft Operating 32F to 95F Non-Operating 5F to 113F Safety Approvals ETL (test followed UL 60950-1 ) RoHS Lifetime For information on Cyberpower products, visit www.CPSww.com Certifications Warranty ETL (test followed UL 60950-1 ) RoHS Lifetime For information on Cyberpower products, visit www.CPSww.com 8 Basic Series ( 0U 10A ) Product Features Front View A B C E Basic Series ( 0U 20A ) Product Features Front View Back View A. AC Inlet (IEC 320 C14) B. Circuit Breaker C. External Site Ground D. Front Outlets E. Cord Retention Tray Screw Holes A A. Bracket Screw Hole B. Keyhole Mount Peg Screw Holes Back View A A B B C F B Twist Type: A. AC Power Cord B. Circuit Breaker C. External Site Ground D. Front Outlets E. Front Outlets F. Cord Retention Tray Screw Holes A. Bracket Screw Hole B. Keyhole Mount Peg Screw Holes C F D D F F F F A B D B A E E F PDU10BVHVIEC16F PDU10BVHVIEC20F F Model Name PDU20BVHVT16F PDU20BVHVT20F PDU20BVHVT24F PDU20BVHVT32F PDU20BVHVT38F PDU20BVHVIEC16F PDU20BVHVIEC20F PDU20BVHVIEC24F PDU20BVHVIEC32F PDU20BVHVIEC38F 200~230V 200~230V Voltage Max Current 10 A Max Current 20 A Input Current Circuit Breaker Plug Type 10 A 10 A Regulatory Derated Input Current 16 A Power Cord Length Output Voltage Max Current Outlet Type(Quantity) IEC C14 10 f t 200~230V 10 A IEC 320 C13(16) IEC 320 C19(4)/C13(16) LED Indicators N/A N/A Physical Dimension (WxDxH) 1.75"x1.5"x24" / 4.45x3.81x60.96 cm 1.75"x1.5"x36" / 4.45x3.81x91.44 cm Altitude Temperature Operating 0 to 95% Non-condensing Non-Operating 0 to 95% Non-condensing Operating 0ft to 10,000ft Non-Operating 0ft to 50,000ft Operating 32F to 95F Non-Operating 5F to 113F Safety Approvals Certifications Warranty ETL (test followed UL 60950-1 ) RoHS Lifetime Voltage Max Current IEC 320 C20 10 f t 200~230V 20 A IEC 320 C13(16) IEC 320 C19(4)/C13(16) IEC 320 C19(4)/C13(20) IEC 320 C19(8)/C13(24) IEC 320 C19(8)/C13(30) Indicators LED Indicators N/A Meter Readout N/A Physical 1.75" x 1.5" x 24" / 4.45 x 3.81 x 60.96 cm 1.75" x 1.5" x 36" / 4.45 x 3.81 x 91.44 cm 1.75" x 1.5" x 48" / 4.45 x 3.81 x 121.92cm 1.75" x 1.5" x 60" / 4.45 x 3.81 x 152.40 cm 1.75" x 1.5" x 70" / 4.45 x 3.81 x 177.80 cm Environmental Humidity Altitude Temperature Operating 0 to 95% Non-condensing Non-Operating 0 to 95% Non-condensing Operating 0ft to 10,000ft Non-Operating 0ft to 50,000ft Operating 32F to 95F Non-Operating 5F to 113F Safety Approvals Certifications Warranty For information on Cyberpower products, visit www.CPSww.com NEMA L6-20P Output Dimension (WxDxH) Environmental Humidity Plug Type Outlet Type(Quantity) Meter Readout 16 A Circuit Breaker Power Cord Length Indicators 9 A Input Input Voltage B E Technical Specifications Technical Specifications Model Name High Voltage Type: A. AC Inlet (IEC 320 C20) B. Circuit Breaker C. External Site Ground D. Front Outlets E. Front Outlets F. Cord Retention Tray Screw Holes ETL (test followed UL 60950-1 ) RoHS Lifetime For information on Cyberpower products, visit www.CPSww.com 10 Basic Series ( 0U 30A ) Product Features Front View A B F Front View A A B C E Product Features Back View A D Meter Series ( 0U 20A ) C Normal Type: A. AC Power Cord B. External Site Ground C. Circuit Breaker (Bank 1) D. Circuit Breaker (Bank 2) E. Cord Retention Tray Screw Holes F. Front Outlets(Bank1) G. Front Outlets(Bank2) D G B Normal Type: A A B B Twist Type: A. AC Power Cord B. Circuit Breaker G C. External Site Ground D. Front Outlets E . Meter Readout F . Front Outlets G . Cord Retention Tray C B A. AC Power Cord B. Bracket Screw Hole C C. Keyhole Mount Peg Screw Holes Back View C A. Bracket Screw Hole B. Keyhole Mount Peg Screw Holes C G A Screw Holes E D D G G E E G G B E G G G C B C E F High Voltage Type: A. AC Power Cord B. Circuit Breaker (Bank 1) C. Circuit Breaker (Bank 2) D . External Site Ground E . Front Outlets(Bank 1) F . Front Outlets(Bank 2) G . Cord Retention Tray Screw Holes High Voltage Type: A. AC Power Cord B. Bracket Screw Hole C. Keyhole Mount Peg Screw Holes B G F High Voltage Type: A. AC Inlet (IEC 320 C20) B . Circuit Breaker C . External Site Ground D . Front Outlets E . Meter Readout F . Front Outlets G . Cord Retention Tray G Technical Specifications Model Name G PDU30BVT14F PDU30BVT16F PDU30BVT20F PDU30BVT28F PDU30BVT32F PDU30BVHVT16F PDU30BVHVT20F PDU30BVHVT32F PDU30BVHVT38F 100 ~ 125 V 200~230V Model Name PDU20MVHVT20F PDU20MVHVT30F PDU20MVHVT38F PDU20MVHVIEC24F PDU20MVHVIEC30F PDU20MVHVIEC38F Input 200~230V Voltage Max Current 30 A Max Current 20 A Regulatory Derated Input Current 24A Regulatory Derated Input Current 16 A Circuit Breaker Plug Type 20 A x 2 16 A x 2 NEMA L5-30P NEMA L6-30P Power Cord Length Voltage Plug Type NEMA L6-20P IEC 320 C20 10 f t Output 100 ~ 125 V 200~230V 30 A Max Current Outlet Type(Quantity) 16 A Circuit Breaker Power Cord Length 10 f t Output NEMA 5-20R(14) NEMA 5-20R(16) NEMA 5-20R(20) NEMA 5-20R(28) NEMA 5-20R(32) Voltage 200~230V Max Current IEC 320 C13(16) IEC 320 C19(4)/C13(16) IEC 320 C19(8)/C13(24) IEC 320 C19(8)/C13(30) Indicators Outlet Type(Quantity) 20 A IEC 320 C19(4)/C13(16) IEC 320 C19(6)/C13(24) IEC 320 C19(8)/C13(30) IEC 320 C19(4)/C13(20) IEC 320 C19(6)/C13(24) IEC 320 C19(8)/C13(30) Indicators LED Indicators N/A LED Indicators N/A Meter Readout N/A Meter Readout Amperage Physical Dimension (WxDxH) Physical 1.75"x2.25"x24" / 4.45x5.72x60.96 cm 1.75"x2.25"x36" / 4.45x5.72x91.44 cm 1.75"x2.25"x48" / 4.45x5.72x121.92cm 1.75"x2.25"x60" / 4.45x5.72x152.40 cm 1.75"x2.25"x70" / 4.45x5.72x177.80 cm 1.75"x1.5"x24" / 4.45x3.81x60.96 cm 1.75"x1.5"x36" / 4.45x3.81x91.44 cm 1.75"x1.5"x60" / 4.45x3.81x152.40 cm 1.75"x1.5"x70" / 4.45x3.81x177.80 cm Environmental Humidity Altitude Temperature Certifications Warranty Dimension (WxDxH) 1.75" x 1.5" x 48" / 4.45 x 3.81 x 121.92 cm 1.75" x 1.5" x 60" / 4.45 x 3.81 x 152.40 cm 1.75" x 1.5" x 70" / 4.45 x 3.81 x 177.80 cm Environmental Operating 0 to 95% Non-condensing Non-Operating 0 to 95% Non-condensing Operating 0ft to 10,000ft Non-Operating 0ft to 50,000ft Operating 32F to 95F Non-Operating 5F to 113F Safety Approvals 11 A Technical Specifications Input Voltage Screw Holes B F Humidity Altitude Temperature Operating 0 to 95% Non-condensing Non-Operating 0 to 95% Non-condensing Operating 0ft to 10,000ft Non-Operating 0ft to 50,000ft Operating 32F to 95F Non-Operating 5F to 113F Safety Approvals ETL (test followed UL 60950-1 ) RoHS Lifetime For information on Cyberpower products, visit www.CPSww.com Certifications Warranty ETL (test followed UL 60950-1 ) RoHS Lifetime For information on Cyberpower products, visit www.CPSww.com 12 Product Registration Metered Series (0U 30A) Product Features Front View Thank you for purchasing a CyberPower product. Prompt product registration entitles coverage under the Limited Warranty and also allows the opportunity to be notified of product enhancements, upgrades, and other announcements. Back View A A A. AC Power Cord A B B. Bracket Screw Hole C. Keyhole Mount Peg Screw Holes B C C D D E F Screw Holes E F I C Hours of Operation: Monday – Friday, 8:00am – 5:00pm (CST) Limited Warranty Read the following terms and conditions carefully before using the CyberPower PDU(the “Product”). By using the Product you consent to be bound by and become a party to the terms and conditions of this Limited Warranty (together referred to as this “Warranty”). If you do not agree to the terms and conditions of this Warranty, you should return the Product for a full refund prior to using it. F I H E CyberPower Technical Support Phone: 1-877-297-6937 Email: tech@cpsww.com Web: www.CPSww.com Mail: 4241 12th Avenue E, Suite 400 Shakopee, MN 55379 F. Front Outlets (Bank 1) G. Meter Readout (Bank 1) H. Meter Readout (Bank 2) I. Front Outlets (Bank 2) G I B E G High Voltage Type: A. AC Power Cord B. Circuit Breaker (Bank 1) C. Circuit Breaker (Bank 2) D. External Site Ground E. Front Outlets (Bank 1) F. Meter Readout (Bank 1) G. Meter Readout (Bank 2) H. Front Outlets (Bank 2) I . Cord Retention Tray Who is Providing this Warranty? CyberPower Systems (USA), Inc. (“CyberPower”) provides this Limited Warranty. C H What Does This Warranty Cover? B Screw Holes E This warranty covers defects in materials and workmanship in the Product under normal use and conditions. I Technical Specifications Model Name What is the Period of Coverage? PDU30MVHVT20F PDU30MVHVT30F PDU30MVHVT38F PDU30MVT24F PDU30MVT32F Input Voltage 100 ~ 125 V 200~230V Max Current 30 A Regulatory Derated Input Current 24A Circuit Breaker Plug Type 16 A x 2 NEMA L5-30P NEMA L6-30P Power Cord Length 10 f t 100 ~ 125 V Outlet Type(Quantity) 200~230V 30 A Max Current IEC 320 C19(4)/C13(16) IEC 320 C19(6)/C13(24) IEC 320 C19(8)/C13(30) NEMA 5-20R(24) NEMA 5-20R(32) Indicators LED Indicators N/A Meter Readout 2 Amperage Physical Dimension (WxDxH) 1.75"x2.25"x60" / 4.45x5.72x152.40 cm 1.75"x2.25"x70" / 4.45x5.72x177.80 cm This Warranty is for as long as the original owner owns the Product. Who Is Covered? This warranty only covers the original purchaser. Coverage ends if you sell or otherwise transfer the Product. How Do You Get Service? 20 A x 2 Output Voltage Need Additional Help? Feel free to contact our Tech Support department with installation, troubleshooting, or general product questions. I Normal Type: A. AC Power Cord B. External Site Ground C. Circuit Breaker (Bank 1) D. Circuit Breaker (Bank 2) E. Cord Retention Tray Registration is quick and easy at www.cpsww.com/register. 1.75"x1.5"x48" / 4.45x3.81x121.92 cm 1.75"x1.5"x60" / 4.45x3.81x152.40 cm 1.75"x1.5"x70" / 4.45x3.81x177.80 cm 1. Call us at (877) 297-6937 or write to us at Cyber Power Systems (USA), Inc., 4241 12th Ave. E., STE 400, Shakopee, MN 55379 or send us an e-mail message at claims@cyberpowersystems.com for instructions. 2. When you contact CyberPower, identify the Product, the Purchase Date, and the item(s) of Connected Equipment. Have information on all applicable insurance or other resources of recovery/payment that are available to the Initial Customer and Request a Claim Number. 3. You must provide a purchase receipt (or other proof of the original purchase) and provide a description of the defect. 4. Pack and ship the product to CyberPower and, if requested, the item(s) of Connected Equipment, a repair cost estimate for the damage to the Connected Equipment, and all claim forms that CyberPower provides to you. Show the Claim Number on the shipping label or include it with the product. You must prepay all shipping costs, you are responsible for packaging and shipment, and you must pay the cost of the repair estimate. What Will We Do To Correct Problems? CyberPower will inspect and examine the Product. Environmental Humidity Altitude Temperature Operating 0 to 95% Non-condensing Non-Operating 0 to 95% Non-condensing Operating 0ft to 10,000ft Non-Operating 0ft to 50,000ft Operating 32F to 95F Non-Operating 5F to 113F Safety Approvals Certifications Warranty 13 ETL (test followed UL 60950-1 ) RoHS Lifetime For information on Cyberpower products, visit www.CPSww.com If the Product is defective in material or workmanship, CyberPower will repair or replace it at CyberPower's expense, or, if CyberPower is unable to or decides not to repair or replace the Product (if defective) within a reasonable time, CyberPower will refund to you the full purchase price you paid for the Product (purchase receipt showing price paid is required). Who Pays For Shipping? We pay when we send items to you; you pay when you send items to us. For information on Cyberpower products, visit www.CPSww.com 14 What Are Some Things This Warranty Does Not Cover? 1. This Warranty does not cover any software that was damaged or needs to be replaced due to the failure of the Product or any data that is lost as a result of the failure or the restoration of data or records, or the reinstallation of software. 2. This Warranty does not cover or apply to: misuse, modification, operation or storage outside environmental limits of the Product or the equipment connected to it, nor for damage while in transit or in storage, nor if there has been improper operation or maintenance, or use with items not designed or intended for use with the Product, such as laser printers, appliances, aquariums, medical or life support devices, etc. What are the Limitations? 1. This Warranty does not apply unless the Product and the equipment that was connected to it were connected to properly wired and grounded outlets (including compliance with electrical and safety codes of the most current electrical code), without the use of any adapters or other connectors. 2. The Product must have been plugged directly into the power source and the equipment connected to the Product must be directly connected to the Product and not “daisy-chained” together in serial fashion with any extension cords, another Product or device similar to the Product, surge suppressor, or power tap. Any such installation voids the Limited Warranty. 3. The Product and equipment connected to it must have been used properly in a suitable and proper environment and in conformance with any license, instruction manual, or warnings provided with the Product and the equipment connected to it. 4. The Product must have been used at all times within the limitations on the Product's VA capacity. 5. The sole and exclusive remedies of the Initial Customer are those provided by this Warranty. Contact Information CyberPower Systems, Inc. 4241 12th Ave. East Suite 400 Shakopee, MN 55379 Phone: (952) 403-9500 Toll-free: (877) 297-6937 CyberPower is the warrantor under this Limited Warranty. You may also contact CyberPower on the web at CPSww.com. 15 For information on Cyberpower products, visit www.CPSww.com For information on Cyberpower products, visit www.CPSww.com 16
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Format : application/pdf Title : cover Creator Tool : Adobe Illustrator CS3 Create Date : 2009:07:30 21:20+09:00 Modify Date : 2010:02:08 19:54:28+08:00 Metadata Date : 2010:02:08 19:54:28+08:00 Thumbnail Width : 184 Thumbnail Height : 256 Thumbnail Format : JPEG Thumbnail Image : (Binary data 10678 bytes, use -b option to extract) Document ID : uuid:6E9CCDA50B7DDE118A0AE78D098CA9A3 Instance ID : uuid:0c801e9a-88a7-40b4-b9c0-1d7c05a77d8f Derived From Instance ID : uuid:6D9CCDA50B7DDE118A0AE78D098CA9A3 Derived From Document ID : uuid:C47A1E11AD45DE11A428C2187C323128 Startup Profile : Print N Pages : 1 Has Visible Transparency : False Has Visible Overprint : False Max Page Size W : 210.001544 Max Page Size H : 297.000067 Max Page Size Unit : Millimeters Font Name : ArialRoundedMTBold, ArialMT, MyriadPro-Regular Font Family : Arial Rounded MT Bold, Arial, Myriad Pro Font Face : Regular, Regular, Regular Font Type : Open Type, Open Type, Open Type Font Version : Version 1.51, Version 3.00, Version 2.007;PS 002.000;Core 1.0.38;makeotf.lib1.7.9032 Font Composite : False, False, False Font File Name : ARLRDBD.TTF, ARIAL.TTF, MyriadPro-Regular.otf Plate Names : Black, PANTONE 185 C Swatch Group Name : Default Swatch Group Swatch Group Type : 0 Swatch Colorant Swatch Name : PANTONE 185 C Swatch Colorant Type : SPOT Swatch Colorant Tint : 100.000000 Swatch Colorant Mode : CMYK Swatch Colorant Cyan : 0.000000 Swatch Colorant Magenta : 91.000402 Swatch Colorant Yellow : 75.999498 Swatch Colorant Black : 0.000000 Producer : Adobe PDF library 8.00 Has XFA : No Page Count : 10 Creator : Adobe Illustrator CS3EXIF Metadata provided by EXIF.tools