D Link DWL900AP-PLUS Wireless Access Point User Manual dwl900AP manual 071002F
D Link Corporation Wireless Access Point dwl900AP manual 071002F
D Link >
Contents
- 1. Manual Part 1
- 2. Manual Part 2
Manual Part 1
D-Link AirPlus DWL-900AP+ 2.4 GHz Wireless Access Point Manual Rev. 071002 Building Networks for People Contents 1. Package Contents ...................................... 3 2. Introduction .................................................. 4 3. Wireless Basics ........................................... 7 4. Getting Started.......................................... 10 5. Using the Configuration Menu .............. 12 6. Using the AirPlus AP Manager.............. 21 7. Troubleshooting ........................................ 25 8. Networking Basics ................................... 30 9. Technical Specifications ........................ 64 10. Contacting Technical Support ............. 66 11. Warranty and Registration ................... 67 1. Package Contents Contents of Package: • • • • • D-Link AirPlus DWL-900AP+ Enhanced 2.4GHz Wireless Access Point Power Supply – 5V DC, 2.0A Manual on CD Quick Installation Guide Ethernet Cable Note: Using a power supply with a different voltage rating than the one included with the DWL-900AP+ will cause damage and void the warranty for this product. If any of the above items are missing, please contact your reseller. System Requirements: • Computer with Windows, Macintosh, or Linux-based operating system with an installed Ethernet adapter • Internet Explorer or Netscape Navigator version 4.0 or above, with JavaScript enabled 2. Introduction The D-Link AirPlus DWL-900AP+ Wireless Access Point is an enhanced 802.11b high-performance wireless access point. It is an ideal way to extend the reach and number of computers connected to your wireless network. Unlike most 802.11b access points, the DWL-900AP+ is capable of data transfer speeds of up to 22 Mbps (compared to the standard 11 Mbps) when used with other D-Link AirPlus products such as the DWL-520+ Wireless PCI Adapter. After completing the steps outlined in the Quick Installation Guide (included in your package) you will have the ability to share information and resources, such as files and printers, and enjoy the freedom that wireless networking delivers. The DWL-900AP+ is compatible with most popular operating systems, including Macintosh, Linux and Windows, and can be integrated into a large network. This Manual is designed to help you connect the Access Point and the D-Link AirPlus 2.4GHz Wireless Adapters into a network in Infrastructure mode. Please take a look at the Getting Started section in this manual to see an example of an Infrastructure network using the DWL-900AP+. This manual provides a quick introduction to wireless technology and its application as it relates to networking. Please take a moment to read through this manual and get acquainted with wireless technology. Connections MDII RJ-45 Ethernet Port • Straight-Through cable is required when connecting to a router or switch • Cross-Over cable is required to connect to a computer Power Reset Button Features & Benefits • Up to 2X Faster with AirPlus Products - high-speed wireless data transfer rates up to 22Mbps. With twice the data rate and capacity, the DWL-900AP+ delivers media rich content such as digital images, videos, and MP3 files much faster than standard 802.11b networks • Fully 802.11b Compatible – Fully compatible with the IEEE 802.11b standard and interoperable with all existing 802.11b compliant devices • Improved Performance – Up to 20% faster data transfer rates on standard 802.11b networks • Stronger Network Security with 256-bit WEP Encryption – Supports 64/128/256-bit WEP encryption for higher level of security for your data and wireless communication than encryption found in existing 802.11b products • Built-in DHCP Server – If enabled, it will automatically assign IP addresses to wireless clients in a temporary network. • Web-based interface for Managing and Configuring – Easy-to-use interface independent of the operating system • 4 Different Operation Modes – Capable of operating in one of four different operation modes to meet your wireless networking requirements: Access Point, AP-to-AP Bridging, AP-to-Multipoint Bridging, and Wireless Client. LEDS LED stands for Light-Emitting Diode. The DWL-900AP+ Wireless Access Point has 3 LEDs as shown below: LAN WLAN Power Power: solid green light indicates connection LAN: blinking green light indicates activity; solid green light indicates connection WLAN: blinking green light indicates wireless activity; solid green light indicates connection 3. Wireless Basics D-Link AirPlus wireless products are based on industry standards to provide easy-to-use and compatible high-speed wireless connectivity within your home, business or public access wireless networks. Strictly adhering to the IEEE standard, the D-Link AirPlus wireless family of products will allow you to securely access the data you want, when and where you want it. You will be able to enjoy the freedom that wireless networking delivers. A wireless local area network (WLAN) is a cellular computer network that transmits and receives data with radio signals instead of wires. Wireless LANs are used increasingly in both home and office environments, and public areas such as airports, coffee shops and universities. Innovative ways to utilize WLAN technology are helping people to work and communicate more efficiently. Increased mobility and the absence of cabling and other fixed infrastructure have proven to be beneficial for many users. Wireless users can use the same applications they use on a wired network. Wireless adapter cards used on laptop and desktop systems support the same protocols as Ethernet adapter cards. Under many circumstances, it may be desirable for mobile network devices to link to a conventional Ethernet LAN in order to use servers, printers or an Internet connection supplied through the wired LAN. A Wireless Access Point (AP) is a device used to provide this link. People use wireless LAN technology for many different purposes: Mobility - Productivity increases when people have access to data in any location within the operating range of the WLAN. Management decisions based on real-time information can significantly improve worker efficiency. Low Implementation Costs – WLANs (Wireless Local Area Networks) are easy to set up, manage, change and relocate. Networks that frequently change, both physically and logically, can benefit from WLANs ease of implementation. WLANs can operate in locations where installation of wiring may be impractical. Installation Speed and Simplicity - Installing a wireless LAN system can be fast and easy and can eliminate the need to pull cable through walls and ceilings. Wireless Basics Network Expansion - Wireless technology allows the network to go where wires cannot go. Reduced Cost-of-Ownership - While the initial investment required for wireless LAN hardware might be higher than the cost of wired LAN hardware, overall installation expenses and life-cycle costs will be significantly lower. Long-term cost benefits are greatest in dynamic environments requiring frequent moves, adds, and changes. Scalability – Wireless Local Area Networks (WLANs) can be configured in a variety of topologies to meet the needs of specific applications and installations. Configurations are easily changed and range from peer-to-peer networks suitable for a small number of users to full infrastructure networks of thousands of users that allow roaming over a broad area. D-Link AirPlus Wireless Family of LAN products include: ♦ Enhanced 2.4GHz Wireless Cardbus Adapters used with laptop computers (DWL-650+) ♦ Enhanced 2.4GHz Wireless PCI cards used with desktop computers (DWL-520+) ♦ Enhanced 2.4GHz Wireless Access Points (DWL-900AP+) ♦ Enhanced 2.4GHz Wireless Broadband Router (DI-614+) The DWL-900AP+ will also work with D-Link Air 802.11b wireless adapters, which include: ♦ 2.4GHz Wireless Cardbus Adapters used with laptop computers (DWL-650) ♦ 2.4GHz Wireless PCI cards used with desktop computers (DWL-520) Standards - Based Technology The IEEE standard-based technology assures that the D-Link AirPlus Products are interoperable with existing compatible 2.4GHz wireless technology. This means you will be able to transfer large files quickly or even watch a movie in MPEG format over your network without noticeable delays. The technology works by using multiple frequencies in the 2.4GHz range at speeds up to 22 Mbps. D-Link AirPlus products will automatically sense the best possible connection speed to ensure optimal network performance. Installation Considerations Designed to go up to 1,312 feet (400 meters) outdoors and up to 328 feet (100 meters) indoors, D-Link’s AirPlus DWL-900AP+ lets you access your network using a wireless connection from virtually anywhere. Keep in mind, however, that the number, thickness and location of walls, ceilings or other objects that the wireless signals must pass through may limit the range. Typical ranges vary depending on the types of materials and background RF (radio frequency) noise in your home or business. The key to maximizing wireless range is to follow these basic guidelines: 1. Keep the number of walls and ceilings between the wireless Access Point and your receiving device (e.g., the DWL-650+) to a minimum Each wall or ceiling can reduce your D-Link AirPlus Wireless product’s range from 3-90 feet (1-30 meters.) Position your Access Points, Residential Gateways, and computers so that the number of walls or ceilings is minimized. 2. Be aware of the direct line between Access Points, Residential Gateways (routers) and computers. A wall that is 1.5 feet thick (.5 meters), at a 45-degree angle appears to be almost 3 feet (1 meter) thick. At a 2-degree angle it looks over 42 feet (14 meters) thick! Try to make sure that the Access Points and adapters are positioned so that the signal will travel straight through a wall or ceiling for better reception. 3. Building Materials make a difference - A solid metal door or aluminum studs may have a negative effect on range. Try to position Access Points, and computers with wireless adapters so that the signal passes through drywall or open doorways and not other materials. 4. Make sure that the device’s antenna is positioned for best reception by using the software signal strength tools included with your product. 5. Keep your product away (at least 3-6 feet or 1-2 meters) from electrical devices or appliances that may generate extreme RF noise. For the average home, signal range should not be an issue. If you experience low or no signal strength in areas of your home that you wish to access, consider positioning the Access Point in a location directly between the computers with wireless adapters. Additional Access Points can be connected to provide better coverage in rooms where the signal does not appear as strong as desired. 4. Getting Started Right out of the box, with its default settings, the DWL-900AP+ will automatically connect with other D-Link Air or AirPlus products. For the price of a single IP Address from your Broadband Internet Service provider you can share the Internet with all the computers on your local network, without sacrificing speed or security, using D-Link AirPlus networking products. IP ADDRESS Please note: If you have a DHCP-capable router, such as the DLink DI-604 or DI-614+, there is no need to assign an IP Address. If you need to assign IP Addresses to the computers on the network, please remember that the IP Address for each computer must be in the same IP Address range as all the computers in the network, and the Subnet mask must be exactly the same for all the computers in the network. For example: If the first computer is assigned an IP Address of 192.168.0.2 with a Subnet Mask of 255.255.255.0, then the second computer can be assigned an IP Address of 192.168.0.3 with a Subnet Mask of 255.255.255.0, etc. IMPORTANT: If computers or other devices are assigned the same IP Address, one or more of the devices may not be visible on the network. An Infrastructure network contains an Access Point. The Infrastructure Network example shown on the next page contains the following D-Link network devices: A wireless Access Point - D-Link AirPlus DWL-900AP+ An Ethernet Broadband Router - D-Link DI-604 A laptop computer with a wireless adapter - D-Link AirPlus DWL-650+ A desktop computer with a wireless adapter - D-Link AirPlus DWL-520+ A Cable modem - D-Link DCM-200 DHCP stands for Dynamic Host Configuration Protocol. It is a protocol for assigning dynamic IP addresses “automatically.” With a DHCP-capable gateway/router, there is no need to manually assign an IP address. 10 Getting Started Setting Up an Infrastructure Network Please refer to the following sections of this manual for additional information about setting up a network: Networking Basics- learn how to check your IP Address; share printers and files. Using the Configuration Utility- learn the settings you must use on each computer in your network for successful communication. Troubleshooting- learn how to check for the proper installation of the network adapters’ drivers and other tips for troubleshooting the network. Please remember that D-Link AirPlus wireless devices are pre-configured to connect together, right out of the box, with the default settings. You will need a broadband Internet access (Cable/DSL) subscription. Consult with your Cable/DSL provider for proper installation of the modem. Connect the modem to an Ethernet Broadband Router (such as the D-Link DI-604) See the Quick Installation Guide included with the DI-604. Connect the router to the D-Link AirPlus DWL-900AP+. Refer to the Quick Installation Guide for setting up the DWL-900AP+. If you are connecting a desktop computer in your network, you can install the D-Link AirPlus DWL-520+ wireless PCI adapter into an available PCI slot. See the Quick Installation Guide included with the DWL-520+. Install the drivers for the wireless cardbus adapter (D-Link AirPlus DWL-650+) into the laptop computer. See the Quick Installation Guide included with the DWL-650+ for installation instructions. 5. Using the Configuration Menu The Configuration Menu for the DWL-900AP+ is web-based. When using the configuration program, please consider the following: You will need a JavaScript-enabled web-browser such as Internet Explorer 4.0 or higher, or Netscape Navigator 4.0 or higher. The computer that you are using for initial configuration must have an IP Address within the same range as the IP Address of the DWL-900AP+. The DWL-900AP+ has a default IP Address of 192.168.0.50 with subnet mask of 255.255.255.0 If you are using a D-Link router in your network, such as the DI-604, with the factory default settings, you will not need to assign a static IP Address to the computer that you are using to configure the Access Point. (Skip to Fig. 5.1: entering the IP address) If you are not using a D-Link router in your network, you will need to assign a Static IP Address to the computer that you are using to configure the DWL900AP+, within the IP Address Range of the DWL-900AP+. Assign a static IP address of 192.168.0.2 with subnet mask of 255.255.255.0 (Please see Networking Basics in this manual for information on Assigning a Static IP Address.) Note: Please write down the current IP address settings of the computer. You may need to revert back to these settings after configuring the DWL-900AP+. After you have assigned a Static IP Address to the computer you are using for configuration (if necessary), next you will assign the DWL-900AP+ an IP Address within the range of your existing network. After changing the DWL-900AP+’s IP Address, you must revert back to the original IP address in order to regain connection to the DWL-900AP+. • If the computer had a static IP address, re-input that same address. • If the computer had a dynamic IP Address (i.e., a DHCP capable router automatically assigns the IP Address) then change the setting of your network adapter to receive a Dynamic IP Address. Factory Default Settings for the DWL-900AP+ SSID Channel Encryption User Name Password default disabled admin IP Address 192.168.0.50 (no password, leave field blank) 12 Using the Configuration Menu Whenever you want to configure your network or the DWL-900AP+, you can access the Configuration Utility by opening the web-browser and typing in the IP Address of the DWL-900AP+. The DWL-900AP+’s default IP Address is shown below: • • Open the web browser Type in the IP Address of the Access Point Fig. 5.1 (The IP Address shown in the example above is the default setting. Use this IP address when connecting to a network consisting of other D-Link devices set to their default settings. If you have changed the IP Address of the DWL-900AP+ to conform to a network other than one with D-Link devices, then input that IP Address in the web browser, instead of the default IP Address shown.) • • • Type admin in the User Name field Leave the Password blank Click OK Fig. 5.2 Home > Wireless The Configuration window will appear. You can select from several options in this window. Here the Home > Wireless tab is displayed. If you wish to change the default settings, you can make changes to the following items: AP name SSID Channel WEP Encryption Key Type Fig. 5.3 Using the Configuration Menu AP Name: You may choose to rename your Access Point, especially if you have more than one Access Point on your network. SSID: (Service Set Identifier) “default” is the default setting. The SSID is a unique name that identifies a network. All devices on a network must share the same SSID name in order to communicate on the network. If you choose to change the SSID from the default setting, input your new SSID name in this field. The SSID can be up to 32 characters in length. Channel: Channel 6 is the default channel. Input a new number if you want to change the default setting. All devices on the network must be set to the same channel to communicate on the network. WEP Encryption: Select Enable Encryption to use WEP (Wired Equivalent Privacy) on the network. All devices on the network, and the Access Point, must share the same WEP selection – either Enable or Disable, and they must share the same WEP key. The WEP key is generated from ASCII or Hexadecimal entries that are either 64, 128, or 256 bit in length. When enabling encryption, select the Key Type (ASCII or Hexadecimal) and then input the appropriate digits or letters. You can create up to 4 keys. Select the key you wish to use. Hexadecimal digits consist of the numbers 0-9 and the letters A-F ASCII (American Standard Code for Information Interchange) is a code for representing English letters as numbers from 0-127 Click Help at any time for more information. Click Apply if you have made any changes or additions. This window displays the default settings of the DWL-900AP+. The default IP Address is 192.168.0.50. If you select Dynamic IP Address, you will obtain a dynamic IP Address from a DHCP server on your network. (This is not advisable since it will be difficult to determine the dynamic IP address assigned to the DWL900AP+.) The Subnet Mask is 255.255.255.0. Input the IP Address of the Gateway (the router on your network.) Click Apply if you have made any changes. 14 Fig. 5.4 Using the Configuration Menu The illustration at right shows the recommended default setting (Disabled) for the DHCP Server function of the DWL-900AP+. If you wish to use the DWL-900AP+ as a DHCP server (not recommended if you already have a DHCP enabled router/gateway on your network) then select Enabled. Enter the IP Address range and click Apply, if you have made any changes. Home > DHCP Fig. 5.5 Advanced > Mode MAC Address (Media Access Control Address) A unique hardware address that identifies a device on a network. It is assigned at the factory and cannot be changed. Usually you will find this address on a sticker on the device or on the packaging. Fig. 5.6 The DWL-900AP+ can be operated in 4 different modes to meet your networking needs. The default setting is Access Point mode. Note: If you select to use the DWL-900AP+ in Wireless Client mode, you will need to input the Wireless MAC Address of the Access Point you wish to associate with. The Wireless Bridge and Multi-point Bridge mode are proprietary modes that will require DWL900AP+’s for both locations. If you select to use the DWL-900AP+ in Wireless Bridge mode, you will need to input the Ethernet MAC Address of the remote DWL-900AP+ rather than the Wireless MAC address. Using the Configuration Menu Advanced > Performance The default Performance settings are shown here. Beacon Interval: Beacons are packets sent by an Access Point to synchronize a wireless network. Specify a Beacon interval value. Default (100) is recommended. RTS Threshold: This value should remain at its default setting of 2,432. If you encounter inconsistent data flow, only minor modifications to the value range between 256 and 2,432 are recommended. Fragmentation: This value should remain at its default setting of 2,346. If you experience a high packet error rate, you may slightly increase your Fragmentation Threshold within the value range of 256 to 2,346. Setting the Fragmentation Threshold too low may result in poor performance. DTIM Interval (Beacon Rate): (Delivery Traffic Indication Message) Enter a value between 1 and 16384 for the Delivery Traffic Indication Message (DTIM.) A DTIM is a countdown informing clients of the next window for listening to broadcast and multicast messages. Transmission Rate: Select the transmission rate for the network Preamble: Long Preamble is the default setting. (High traffic networks should use the shorter preamble type.) The preamble defines the length of the CRC block (Cyclic Redundancy Check is a common technique for detecting data transmission errors) used in communication between the Access Point and the roaming wireless Network adapters. Authentication: Open System – communicates the key across the network Shared Key – devices must have identical WEP settings to communicate Auto – automatically adjusts to the Authentication mode of the wireless client Antenna Type: Select Left, Right or both (Diversity) antenna SSID Broadcast: (Service Set Identifier) Enable or Disable (default) the broadcast of the SSID name across the network. SSID is a name that identifies a wireless network. All devices on a network must use the same SSID to establish communication. 16 Using the Configuration Menu Advanced > Filters Fig. 5.8 Use MAC Filters to allow or deny wireless connection to the DWL900AP+. Select Disable MAC Filters (default) to disable this feature. Select Only allow the MAC address… or Only deny the MAC address… and enter the MAC Address of the selected computer into the field above. Or you can click on the pull-down arrow next to the Connected PCs field, select the computer from the list, and click Clone. The MAC address you have chosen will appear in the MAC Filter List. Click Apply to save your choices. Tools > Admin Change your password in this window. It can be up to 14 characters in length. Please keep a copy of your password in a safe place. Click Apply, if you have made any changes. Fig. 5.9 Using the Configuration Menu Tools > System The current system settings can be saved as a file onto the local hard drive by clicking Save. The saved file can be loaded back on the DWL-900AP+ by clicking Browse. When you have selected the settings file, click Load. Click Restore to return to Factory Default Settings. Fig. 5.10 Tools > Firmware Upgrade the firmware for the Access Point. Click on the link to find upgrades to the firmware on the D-Link website at http://support.dlink. com. After you have downloaded a firmware upgrade to your local drive, click Browse. Select the firmware and click Apply to complete the upgrade. Fig. 5.11 18 Using the Configuration Menu This page displays the current information for the DWL-900AP+. It will display the Ethernet and Wireless information. Ethernet: MAC Address IP Address Subnet Mask Gateway DHCP Server Wireless: MAC Address SSID Encryption Channel AP mode Status > Device Info Fig. 5.12 Status > Log The DWL-900AP+ keeps a running log of events and activities occurring on the Access Point. If the device is rebooted, the logs are automatically cleared. You may save the log files under Log Settings. To enable or disable logging for the Access Point, click on Log Settings. To monitor the wireless stations, select Enable and the log file will be sent to the associated computer. Fig. 5.13 First Page - displays the first page of the Log Last Page - displays the last page of the Log Previous - moves back one log page Next - moves forward one log page Clear - clears the log completely Log Settings – Brings up the page to configure the logs Using the Configuration Menu Status > Stats Displays the network traffic statistics for both received and transmitted communications through the Ethernet port and wireless connections associated with the Access Point. Fig. 5.14 Status > Wireless Displays the list of computers that are connected to the DWL-900AP+ wirelessly. Fig. 5.15 20 6. Using the AirPlus AP Manager The AirPlus Access Point Manger is a Windows based program to help you manage multiple Access Points in one easy view. • • Begin the installation by inserting the DWL-900AP+ CD into your CDROM. The AP Manager is also available for download at support.dlink.com. Click Install AirPlus AP Manager • The following screen will appear. • Click Next • Click Next • Click Finish to complete installation. Using the AirPlus AP Manager Link Information The Link Information screen displays the current settings of the selected Access Point AP Settings The AP Settings screen will allow you to change the Access Point settings for the selected Access Point. AP Settings > Advanced Settings The Advanced Settings will allow you to adjust advanced settings for the selected Access Point. 22 Using the AirPlus AP Manager IP Settings The IP Settings screen will allow you to change the IP Address settings for the selected Access Point. WEP Settings The WEP Settings Screen will allow you to apply Wireless Encryption Protocol to the selected Access Point. Using the AirPlus AP Manager Firmware Upgrade The Firmware Upgrade screen will allow you to apply new version of the firmware to selected Access Point. 24 7. Troubleshooting This chapter provides solutions to problems that can occur during the installation and operation of the DWL-900AP+ Wireless Access Point. We cover various aspects of the network setup, including the network adapters. Please read the following if you are having problems. Note: It is recommended that you use an Ethernet connection to configure the DWL-900AP+ Access Point. 1. The computer used to configure the DWL-900AP+ cannot access the Configuration menu. • Check that the Ethernet LED on the DWL-900AP+ is ON. If the LED is not ON, check that the cable for the Ethernet connection is securely inserted. • Check that the Ethernet Adapter is working properly. Please see item 3 (Check that the drivers for the network adapters are installed properly) in this Troubleshooting section to check that the drivers are loaded properly. • Check that the IP Address is in the same range and subnet as the DWL-900AP+. Please see Checking the IP Address in Windows XP in the Networking Basics section of this manual. Note: The IP Address of the DWL-900AP+ is 192.168.0.50. All the computers on the network must have a unique IP Address in the same range, e.g., 192.168.0.x. Any computers that have identical IP Addresses will not be visible on the network. They must all have the same subnet mask, e.g., 255.255.255.0 • Do a Ping test to make sure that the DWL-900AP+ is responding. Go to Start>Run>Type Command>Type ping 192.168.0.50. A successful ping will show four replies. Troubleshooting 2. The wireless client cannot access the Internet in the Infrastructure mode. • Make sure the wireless client is associated and joined with the correct Access Point. To check this connection: Right-click on the Local Area Connection icon in the taskbar> select View Available Wireless Networks. The Connect to Wireless Network screen will appear. Please make sure you have selected the correct available network, as shown in the illustrations below. Default • Check that the IP Address assigned to the wireless adapter is within the same IP Address range as the access point and gateway. Since the DWL-900AP+ has an IP Address of 192.168.0.50, wireless adapters must have an IP Address in the same range, e.g., 192.168.0.x. Each device must have a unique IP Address; no two devices may have the same IP Address. The subnet mask must be the same for all the computers on the network.) To check the IP Address assigned to the wireless adapter, double-click on the Local Area Connection icon in the taskbar > select the Support tab and the IP Address will be displayed. (Please refer to Checking the IP Address in the Networking Basics section of this manual.) • If it is necessary to assign a Static IP Address to the wireless adapter, please refer to the appropriate section in Networking Basics. If you are entering a DNS Server address you must also enter the Default Gateway Address. (Remember that if you have a DHCP-capable router, you will not need to assign a Static IP Address. See Networking Basics: Assigning a Static IP Address.) 26 Troubleshooting 3. Check that the drivers for the network adapters are installed properly. You may be using different network adapters than those illustrated here, but this procedure will remain the same, regardless of the type of network adapters you are using. • Go to Start • Right-click on My Computer • Click Properties • Select the Hardware Tab • Click Device Manager Troubleshooting • Double-click on Network Adapters • Right-click on D-Link AirPlus DWL-650+ Wireless Cardbus Adapter • Select Properties to check that the drivers are installed properly D-Link AirPlus DWL-650 Wireless Cardbus Adapter D-Link AirPlus DWL-650+ Wireless Cardbus Adapter • Look under Device Status to check that the device is working properly. D-Link AirPlus DWL-650+ Wireless Cardbus Adapter • Click OK 28 Troubleshooting 4. Resetting the DWL-900AP+ to Factory Default Settings After you have tried other methods for troubleshooting your network, you may choose to Reset the DWL-900AP+ to the factory default settings. Remember that D-Link AirPlus products network together, out of the box, at the factory default settings. To hard-reset the D-Link AirPlus DWL-900AP+ to Factory Default Settings, please do the following: • Locate the Reset button on the back of the DWL-900AP+ • Use a paper clip to press the Reset button. • Hold for about 5 seconds and then release • After the DWL-900AP+ reboots (this may take a few minutes) it will be reset to the factory Default settings. 8. Networking Basics Using the Network Setup Wizard in Windows XP In this section you will learn how to establish a network at home or work, using Microsoft Windows XP. Note: Please refer to websites such as http://www.homenethelp.com and http://www.microsoft.com/windows2000 for information about networking computers using Windows 2000, ME or 98. Go to Start>Control Panel>Network Connections Select Set up a home or small office network When this screen appears, Click Next. 30 Networking Basics Please follow all the instructions in this window: Click Next In the following window, select the best description of your computer. If your computer connects to the Internet through a gateway/router, select the second option as shown. Click Next Networking Basics Enter a Computer description and a Computer name (optional.) Click Next Enter a Workgroup name. All computers on your network should have the same Workgroup name. Click Next 32 Networking Basics Please wait while the Network Setup Wizard applies the changes. When the changes are complete, click Next. Please wait while the Network Setup Wizard configures the computer. This may take a few minutes. Networking Basics In the window below, select the option that fits your needs. In this example, Create a Network Setup Disk has been selected. You will run this disk on each of the computers on your network. Click Next. Insert a disk into the Floppy Disk Drive, in this case drive A. Format the disk if you wish, and click Next. 34 Networking Basics Please wait while the Network Setup Wizard copies the files. Please read the information under Here’s how in the screen below. After you complete the Network Setup Wizard you will use the Network Setup Disk to run the Network Setup Wizard once on each of the computers on your network. To continue click Next. Networking Basics Please read the information on this screen, then click Finish to complete the Network Setup Wizard. The new settings will take effect when you restart the computer. Click Yes to restart the computer. You have completed configuring this computer. Next, you will need to run the Network Setup Disk on all the other computers on your network. After running the Network Setup Disk on all your computers, your new wireless network will be ready to use. 36 Networking Basics Naming your Computer To name your computer, please follow these directions: In Windows XP: • Click Start (in the lower left corner of the screen) • Right-click on My Computer • Select Properties and click • Select the Computer Name Tab in the System Properties window. You may enter a Computer description if you wish, this field is optional. To rename the computer and join a domain, • Click Change Networking Basics Naming your Computer • In this window, enter the Computer name. • Select Workgroup and enter the name of the Workgroup. • All computers on your network must have the same Workgroup name. • Click OK Checking the IP Address in Windows XP/2000 Go to Start > All Programs > Accessories > Command Prompt 38 Networking Basics Checking the IP Address in Windows XP/2000 Type Command Click OK Checking the IP Address in Windows XP/2000 Type ipconfig /all at the prompt. Press Enter. All the configuration settings are displayed as shown below. D-Link AirPlus DWL-650+ Wireless Cardbus Adapter
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Encryption : Standard V1.2 (40-bit) User Access : Print, Copy, Fill forms, Extract, Assemble, Print high-res Modify Date : 2002:08:16 17:05:02+08:00 Create Date : 2002:08:16 17:04:15+08:00 Title : Microsoft Word - dwl900AP+_manual_071002F.doc Author : baller Creator : ADOBEPS4.DRV Version 4.50 Producer : Acrobat Distiller 5.0 (Windows) Page Count : 39 Mod Date : 2002:08:16 17:05:02+08:00 Creation Date : 2002:08:16 17:04:15+08:00 Metadata Date : 2002:08:16 17:05:02+08:00 Has XFA : NoEXIF Metadata provided by EXIF.tools