D O Tel DOTR-221 UHF RFID READER User Manual DOTR 928 1

D.O.Tel Co., Ltd. UHF RFID READER DOTR 928 1

User Manual

 DOTR-221 READER MODULE USER GUIDE     D.O.Tel Co., Ltd. #412, Kolon Science Valley 2nd 811 Gurodong, SEOUL, KOREA      152-878  Copyright 2008  Note: FCC Section 15.21 "Changes or modifications not expressly approved by the party responsible for compliancecould void the user's authority to operate the equipment."
Chapter 1 INTRODUCTION  The  DOTR-221  module  is  a  compact  UHF  RFID  reader  module  which  is compliant with the ISO-18006C (EPC class1 Gen2) protocol. It is intended to be  used  in conjunction with the accompanying antenna  and  a host  computer (not  supplied).  The  small  physical  size  allows  the  module  to  be  easily integrated with a mobile host computer, such as a Personal Digital Assistant. The module is designed to be operated off a single cell lithium ion battery, and has two host interface options: USB and UART.    WARNING 1. ESD precautions: This module contains electrostatic sensitive components. Handle  the  product  at  a  static-free  workstation,  and  wear  a  static  grounding strap always. Observe standard ESD precautions.  2.  This  module  does  not  contain  fuses  or  other  protective  devices.  Be  extra careful when applying power to make sure voltage and polarity are correct.  3. Do not attempt to open the cover. There are no serviceable parts inside.    4. Provide good thermal conduction of the module or good ventilation around the module. As the module consumes around 4 watts of power, it can be hot when operated continuously. Adequate  cooling should be  provided to ensure reliability.  5. Do not operate the product in an explosive atmosphere or in the presence of flammable gases or fumes.
Chapter 2 Specifications  Mechanical Characteristics  Dimension: 44mm X 44mm X 8.1mm Weight: 20g approx.  Mounting holes: M2 (4 places)
Electrical Specifications  ABSOLUTE MAXIMUM RATING: Power Supply Voltage: 4.2V DC max Control / UART port voltage: -0.3 ~ +3.9VDC USB pin Voltage; -0.3 ~ +5.3VDC Operating Temperature: 55 deg C   Storage Temperature: -40 to 70 deg C (non-operating)  Note:  Stress  above  the  maximum  rating  may  cause  permanent  damage. Exposure to the maximum rating for extended periods may degrade reliability.     Performance Characteristics Summary Power Supply Voltage: 3.4V to 4.2V DC Power Consumption: 1.2A max. RF Output Power: 0.6W (27.8dBm) ± 1dB RF Frequency: 902.75MHz to 927.5MHz (50 frequency hopping channels) Antenna Port Impedance: 50 Ω Unbalanced Recommended Return Loss of Antenna: 20dB Air Interface Protocol: ISO-18006C (EPC C1 Gen2) Host Interface: USB (Full speed 12Mbps)                           UART(115.2kbps, 8N1, No Flow Control)                                       Logic Level 3.3V nominal    Electrical Connector Manufacturer: Molex   Part Number on Reader Module: 53261-1271 Mating Connector: 51021-1200 (with 50125 terminals)  Antenna Connector: Hirose U.FL
DETAILED ELECTRICAL SPECIFICATIONS 1. RF FREQUENCY CHANNELS CHANNEL FREQ (MHz)  CHANNEL  FREQ (MHz) 1  902.75  26  915.25 2  903.25  27  915.75 3  903.75  28  916.25 4  904.25  29  916.75 5  904.75  30  917.25 6  905.25  31  917.75 7  905.75  32  918.25 8  906.25  33  918.75 9  906.75  34  919.25 10  907.25  35  919.75 11  907.75  36  920.25 12  908.25  37  920.75 13  908.75  38  921.25 14  909.25  39  921.75 15  909.75  40  922.25 16  910.25  41  922.75 17  910.75  42  923.25 18  911.25  43  923.75 19  911.75  44  924.25 20  912.25  45  924.75 21  912.75  46  925.25 22  913.25  47  925.75 23  913.75  48  926.25 24  914.25  49  926.75 25  914.75  50  927.25
CHAPTER 3 HOST INTERFACE 3.1 CONNECTION   PIN  NAME  I/O  Description 1  BAT  In  VCC SUPPLY , +3.7V input 2  BAT  In  VCC SUPPLY , +3.7V input 3  USB_M  I/O  USB Interface 4  USB_P  I/O  USB Interface 5  GND  Common Ground 6  GND  Common Ground 7  GND  Common Ground 8  TXD  Out  UART TX Data 9  RXD  In  UART RX Data 10  GP0  In  Enable (Applying 3.3V will enable the module) 11  GP1  In  Reserved  for  FACTORY  USE.  DO  NOT CONNECT    TO ANYTHING. 12  USB 5V  In  USB  Vbus  Voltage  (+5V).  This  pin  is  for sensing the USB Host only. The module is not powered from this voltage. Notes:   1.  All  of  the  supply  pins  (Pins  1,2,  5,  6,  and  7)  must  be  used  in  order  to minimize voltage drop at the connector junctions. 2. TX / RX and I/O classification is from the module’s point of view. 3. Leave pin 11 open. Do not apply any voltage, or the module  will become non-functional.   3.2 TTL INTERAFACE UART communication is provided on  the TXD  and RXD lines. Baud rate is
fixed at 115.2kbps and no handshaking (8 data bits, no parity, 1 stop bit). Details for communication protocols are described in the software chapter. 3.3 USB Interface The module provides full speed compliant USB interface (12Mbps).   Note: The module is set to communicate via UART port at the factory.
 CHAPTER 4 Operation 4.1 Antenna Connection A good antenna must be connected before applying power. The antenna must have a low VSWR value (less than 1.25) in the entire frequency range of 902 through 928MHz to ensure maximum read range performance. Care should be taken  when  connecting  the  antenna  cable  to  the  antenna  connector,  as  the antenna connector is very small and fragile.   4.2 Power Supply The  reader  module  is  designed  to  operate  off  3.7V  nominal  supply  voltage which is typically available from a single cell lithium ion battery. Other power sources can be used as long as it is within the specified voltage range of 3.4V to  4.2V.  Care  must  be  excersized  for  correct  polarity.  Pins  5,  6,  7  and  the housing are ground while Pins 1 and 2 should be connected to +3.7V.  4.3 GP0 and GP1 ports. GP0  (Pin  10)  port  is  an  active  high  enable  control  to  power  up  the  reader module.  A  logic  voltage  above  2.5V  (?)  will  turn  on  the  reader  while  level below 0.5V (?) will turn off the reader. GP1 (Pin 11) should be left open for internal pull-down to work. Pulling the GP0 and GP1 ports to a high level will erase entire contents of internal flash memory. This mode is used at the factory. Consult with the manufacturer to use this function.  4.4 TXD and RXD ports TXD  (Pin  8)  and  RXD (pin  9)  are  UART  communication  ports  and  TX/RX notation  is  from  the  reader  module’s  point  of  view.  These  ports  provide  a single speed (115.2kbps) serial communication without flow control, and the nominal  logic  level  is  3.3V.  While  the  module  has  a  provision  for  USB
interface,  UART communication is  the default  mode of  communication with the host.  4.5 USB port Pin 3 (USB-M), Pin 4 (USB-P) and Pin 12 (USB +5V) provide connection to a  USB host at full  speed. USB +5V  line is used to detect  the USB host and does not consume power.    4.6 Installation of software 4.6.1 Application software package The application software consists of several dlls and applications. These  are  rfidhost.inv.exe,  rfidhost.test.exe,  cpl.dll,  rfidtx.dll,  rfid.dll  and profiler.dll. Also USB device driver is included   4.6.2 Installing the USB Communication-Bus Driver on Windows XP The RFID Radio Module is a USB Plug-and-Play device. Installation of the driver on Windows XP is a simple procedure: 1. Plug the RFID Radio Module into a USB port on the machine where you have installed the application software. 2. When asked to specify additional locations to search for driver software, enter APP_DIR\USB.Driver. 3. When shown a list of devices to select, select the device labeled: UsbHarve.Sys for Intel Harve RFID MAC 4. This driver has not been signed by Microsoft; When asked, continue with installation of the unsigned driver
CHAPTER 5 Quality Policy  D.O.Tel’s  quality  policy  is  that  we  are  committed  to  meet  and  exceed  our customer’s requirements and expectations of all our products and services. We strive  to  understand,  maintain,  communicate  and  continually  improve  our quality management system.       CUSTOMER SERVICE CENTER   #412, Kolon Science Valley 2nd   811 Gurodong,   SEOUL, KOREA      152-878   PHONE: 82-2-850-3636   FAX: 82-2-850-3637   e-mail: dotel@dotel.co.kr
 - Additional Page -  Cautions     Modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.  FCC compliance Information This device complies with part 15 of FCC Rules. Operation is subject to the following two conditions: 1. This device  may  not  cause harmful  interference,  and  2.  This  device  must  accept  any  interference  received. Including interference that may cause undesired operation.  Information to User This equipment has been tested and found to comply with the limits  for  a  Class  B digital  device,  Pursuant  to  part  15  of  the  FCC  Rules.  These  limits  are  designed  to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio Frequency energy  and,  if  not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver - Connect the equipment into an outlet on a circuit different from  that  to  which  the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help.  FCC WARNING:    This equipment may generate or use radio frequency energy.  Changes or modifications to this equipment may cause harmful interference unless the modifications  are expressly approved in the instruction manual.  The user could lose the authority  to  operate  this equipment if an unauthorized change or modification is made.  FCC RF EXPOSURE: The EUT will only be used with a separation of 20 centimeters or greater between the antenna and the body of the user.