DASAN Zhone Solutions 281XP Optical Network Terminal (ONT) User Manual zNID 28xx Hardware Installation Guide
Zhone Technologies, Inc. Optical Network Terminal (ONT) zNID 28xx Hardware Installation Guide
User manual rev1
Zhone 2800 Series FiberJACK ONT Hardware Installation Guide For software version 3.0 August 2015 Document Part Number: 830-03974-02 Zhone Technologies @Zhone Way 7195 Oakport Street Oakland, CA 94621 USA 510.777.7000 www.zhone.com info@zhone.com COPYRIGHT C2000-2015 Zhone Technologies, Inc. and its licensors. All rights reserved. This publication is protected by copyright law. No part of this publication may be copied or distributed, transmitted, transcribed, stored in a retrieval system, or translated into any human or computer language in any form or by any means, electronic, mechanical, magnetic, manual or otherwise, or disclosed to third parties without the express written permission from Zhone Technologies, Inc. Bitstorm, EtherXtend, EZ Touch, FiberJACK, IMACS, MALC, MXK, Raptor, SLMS, Z-Edge, Zhone, ZMS, zNID and the Zhone logo are trademarks of Zhone Technologies, Inc. Zhone Technologies makes no representation or warranties with respect to the contents hereof and specifically disclaims any implied warranties of merchantability, non infringement, or fitness for a particular purpose. Further, Zhone Technologies reserves the right to revise this publication and to make changes from time to time in the contents hereof without obligation of Zhone Technologies to notify any person of such revision or changes. Zhone 2800 Series FiberJACK ONT Hardware Installation Guide TABLE OF CONTENTS About This Guide ..............................................................................................................................5 Style and notation conventions .............................................................................5 Typographical conventions.......................................................................................6 Related documentation.............................................................................................7 Acronyms......................................................................................................................7 Contacting Global Service and Support...............................................................8 FCC Statement ............................................................................................................9 MPE Requirements ...................................................................................................9 Region Selection .....................................................................................................10 CE..................................................................................................................................10 Important Safety Instructions................................................................................11 Laser Safety Instructions.........................................................................................11 Electrical Installation Instructions ..........................................................................12 General Instructions ................................................................................................12 EMI Precautions ........................................................................................................13 Canada.....................................................................................................................13 Chapter 1 Zhone 2800 Series FiberJACK ONT...............................................................15 Overview ....................................................................................................................15 Zhone 2800 Series FiberJACK ONT components..................................................16 Zhone 2800 Series FiberJACK ONT features ....................................................18 Zhone 2800 Series FiberJACK ONT models .........................................................18 GPON models...................................................................................................19 Gigabit Ethernet models...................................................................................20 Zhone 2800 Series FiberJACK ONT specifications...............................................21 Zhone 2800 Series FiberJACK ONT dimensions .............................................27 Zhone 2800 Series FiberJACK ONT controls and switches .........................29 Power On/Off Switch..............................................................................................30 Reset Button............................................................................................................31 LED Mode Selector Switch ....................................................................................31 Tamper Detection Switch .......................................................................................31 Zhone 2800 Series FiberJACK ONT LEDs .........................................................32 Logging in to the 2800 Series ONT ......................................................................35 Zhone 2800 Series FiberJACK ONT Hardware Installation Guide Table of contents Chapter 2 Zhone 2800 Series FiberJACK ONT Installation ......................................37 Install the FiberJACK ONT .....................................................................................38 Installation precautions ...........................................................................................39 Providing power to the wallbox ............................................................................46 Power connections ..................................................................................................50 3 pin ONT power pigtail for 115/120VAC connections.........................................50 3 wire ONT power for 115/120VAC connections using wire nuts ........................51 3 pin ONT power pigtail for 220/240VAC connections.........................................51 2 pin DC connection ...............................................................................................52 RJ-45 DC Power over Ethernet connection ............................................................52 Manage the optical cable .......................................................................................54 Fiber handling .........................................................................................................54 Testing optical power..............................................................................................54 Connect to network cautions ................................................................................55 Index ......................................................................................................................................................57 Zhone 2800 Series FiberJACK ONT Hardware Installation Guide About This Guide This guide is intended for use by installation technicians, system administrators, or network administrators. It explains how to install the Zhone 2800 Series FiberJACK ONT, electronics and cabling. Style and notation conventions This document uses the following conventions to alert users to information that is instructional, warns of potential damage to system equipment or data, and warns of potential injury or death. Carefully read and follow the instructions included in this document. Caution: A caution alerts users to conditions or actions that could damage equipment or data. Note: A note provides important supplemental or amplified information. Tip: A tip provides additional information that enables users to more readily complete their tasks. WARNING! A warning alerts users to conditions or actions that could lead to injury or death. WARNING! A warning alerts users to conditions or actions that could lead to injury caused by a laser. WARNING! This icon warns the user that metal surfaces can become hot to touch. Avoid contact or use caution when touching these surfaces. Zhone 2800 Series FiberJACK ONT Hardware Installation Guide About This Guide Typographical conventions The following typographical styles are used in this guide to represent specific types of information. Bold Used for names of buttons, dialog boxes, icons, menus, profiles when placed in body text, and property pages (or sheets). Also used for commands, options, parameters in body text, and user input in body text. Fixed Used in code examples for computer output, file names, path names, and the contents of online files or directories. Fixed Bold Used in code examples for text typed by users. Fixed Bold Italic Used in code examples for variable text typed by users. Italic Used for book titles, chapter titles, file path names, notes in body text requiring special attention, section titles, emphasized terms, and variables. PLAIN UPPER CASE Used for environment variables. Zhone 2800 Series FiberJACK ONT Hardware Installation Guide Related documentation Related documentation Refer to the following publication for additional information: • The FiberJACK Quick Installation Instructions for the model of ONT you are installing. These instructions are shipped with the ONT, but are also available on the Zhone website. • Zhone zNID Configuration Guide — explains how to use the ONT web interface and describes the system commands and parameters. Refer to the release notes for software installation information and for changes in features and functionality of the product (if any). Acronyms The following acronyms are related to Zhone products and may appear throughout this manual: Table 1: Acronyms and their descriptions Acronym Description Active E Active Ethernet, also known as Gigabit Ethernet APC Angled physical contact (for fiber connector) Coax Coaxial cable CNI Comfort Noise Insertion CPE Consumer Premises Equipment DHCP server Dynamic host configuration protocol server EZ touch™ Zhone’s implementation for managing CPEs and ONTs GigE Gigabit Ethernet GPON Gigabit passive optical network HPNA Home phone line networking alliance IPTV Internet protocol TV LED Light-emitting diode MALC Multi-access line concentrator MDU Multiple Dwelling Unit MIB Management information bases MoCA Multimedia over Coax Alliance OLT Optical Line Terminator ONT Optical Network Terminator Zhone 2800 Series FiberJACK ONT Hardware Installation Guide About This Guide Table 1: Acronyms and their descriptions (Continued) Acronym Description ONU Optical Network Unit PoE Power over Ethernet PPPoE Point-to-point protocol over Ethernet QoS Quality of service RF Radio Frequency RFoG Radio Frequency over Glass SC adaptor Subscriber connector adaptor SIP Session initiation protocol SNMP Simple network management protocol T1/E1 T1 is Trunk line 1 (or DS 1, digital signal level 1). E1 is the European equivalent, though there are a number of differences between the North American T1 and the European E1. UPC Ultra physical contact (for fiber connector) USP Unified Service Provisioning Wi-Fi Wireless local area network (trademark of Wi-Fi alliance) VAD Voice Activity Detection VOIP Voice over IP zNID Zhone Network Interface Device ZMS Zhone Management System Contacting Global Service and Support Support for this product is provided by your Internet service provider Zhone 2800 Series FiberJACK ONT Hardware Installation Guide FCC Statement FCC Statement This device complies with Part 15 of the FCC Rules / Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. MPE Requirements To satisfy FCC / IC RF exposure requirements, a separation distance of 20 cm or more should be maintained between the antenna of this device and persons during device operation. To ensure compliance, operation at closer than this distance is not recommended. Les antennes installées doivent être situées de facon à ce que la population ne puisse y être exposée à une distance de moin de 20 cm. Installer les antennes de facon à ce que le personnel ne puisse approcher à 20 cm ou moins de la position centrale de l' antenne. La FCC des éltats-unis stipule que cet appareil doit être en tout temps éloigné d'au moins 20 cm des personnes pendant son functionnement. Zhone 2800 Series FiberJACK ONT Hardware Installation Guide About This Guide Region Selection Limited by local law regulations, versions for North America do not have region selection options. The device for operation in the band 5150-5250 MHz is only for indoor use to reduce the potential for harmful interference to co-channel mobile satellite. CE CE compliance certifications has been obtained for the following equipment: • • ZNID-GPON-2804P-WAC • zNID-GPON-2812P-WAC • zNID-GPON-2812P-WDC • zNID-GPON-2813P-WAC • zNID-GPON-2813P-WDC • zNID-GPON-2814P-WAC • zNID-GPON-2814P-WDC • zNID-GPON-2815P-WAC • • • zNID-GPON-2815P-WDC • zNID-GE-2812P-WAC • zNID-GE-2812P-WDC • zNID-GE-2814P-WAC • zNID-GE-2814P-WDC ZNID-GPON-2804P-WDC ZNID-GE-2804P-WAC ZNID-GE-2804P-WDC The equipment named above is confirmed to comply with the requirements setout in the Council Directive on the Approximation of the Laws of the Member States relating to Electromagnetic Compatibility (2004/108/EC), Low-voltage Directive (2006/95/EC) and R&TTE (1999/5/EC). The equipment passed the test which was performed according to the following European standards: 10 • ETSI EN 301 489-17 V2.1.1: 2009 • ETSI EN 301 489-1 V1.9.2: 2011 • ETSI EN 300 328 V1.7.1: 2006 • EN 62311: 2008 • EN 60950-1: 2006+A11 2009+ A1:2010 + A12:2011 Zhone 2800 Series FiberJACK ONT Hardware Installation Guide Important Safety Instructions Important Safety Instructions Read and follow all warning notices and instructions marked on the product and included in the manual. Veuillez lire et respecter toutes les notices d'avertissement et les instructions indiquées sur le produit et inclues dans le manuel. Laser Safety Instructions Zhone equipment and associated optical test sets use laser sources that emit light energy into fiber cables. This energy is within the red (visible) and infrared (invisible) regions of the electromagnetic spectrum. Laser products are subject to federal and state or provincial regulations, and local practices. Regulation 21 CFR 1040 of the U.S. Bureau of Radiological Health requires manufacturers to certify each laser product as Class I, II, III, or IV, depending upon the characteristics of the laser radiation emitted. In terms of health and safety, Class I products present the least hazard (none at all), while Class IV products present the greatest hazard. Although Zhone optical products have a Class I certification, hazardous exposure to laser radiation can occur when fibers connecting system components are disconnected or broken. Certain procedures carried out during testing require the handling of optical fibers without dust caps and therefore increase the risk of exposure. Exposure to either visible or invisible laser light can damage your eyes under certain conditions. Read and observe the following precautions to decrease the risk of exposure to laser radiation. WARNING! Risk of eye damage. At all times, when handling optical fibers, follow the safety procedures recommended by your company. WARNING! Avoid direct exposure to fiber ends or optical connector ends. Laser radiation may be present and can damage your eyes. WARNING! Never look into an active optical fiber or an optical fiber connector opening of an active or powered-up unit. Note: When working with optical fibers, take these precautions: • Wear safety glasses when installing optical fibers. • Clean hands after handling optical fibers. Small pieces of glass are not always visible and can cause eye damage. Get medical assistance immediately for any glass that comes into eye contact. Zhone 2800 Series FiberJACK ONT Hardware Installation Guide 11 About This Guide • Prevent direct exposure to optical fiber ends or optical connector ends where laser signals are directly accessed. Do not handle pieces of optical fiber with fingers. Use tweezers or adhesive tape to lift and discard any loose optical fiber ends. • Wear rubber gloves to clean optical connectors. The gloves prevent direct contact with the isopropyl alcohol and prevent contamination of the ferrules with skin oils. • Place all optical fiber clippings in a plastic container provided for that purpose. • Handle optical fibers with caution. Place the optical fibers in a safe location during installation. • Follow the manufacturer instructions when using an optical test set. Incorrect calibration or control settings can create hazardous levels of radiation. Electrical Installation Instructions WARNING! Installing electrical wires, especially for the AC installations, may be hazardous and could lead to serious injury or possibly death. Disconnect power before conducting the installation. Take all proper precautions or have a qualified electrician perform the tasks for installing electrical wiring. • Installing electrical equipment may be hazardous. If you do not have the skills necessary to properly install electrical wiring, do not proceed with the installation, but have a qualified electrician perform the electrical wiring part of the installation. • Comply with all local building and electrical codes, including the wiring gauge. General Instructions Other precautions to take before installing or servicing the product are as follows: 12 • Never install telephone wiring during a lightning storm. • Never touch uninsulated telephone wires or terminals unless the telephone line has first been disconnected at the network interface. • Use caution when installing or modifying telephone lines. • Only authorized service technicians can service this product. Unauthorized service to this product can cause exposure to dangerous high-voltage points or other risks and may result in injury or damage to the unit and void all warranties. • Special cables, which may be required by the regulatory inspection authority for the installation site, are the responsibility of the buyer. Zhone 2800 Series FiberJACK ONT Hardware Installation Guide Important Safety Instructions • When installed in the final configuration, the product must comply with the applicable Safety Standards and regulatory requirements of the country in which it is installed. If necessary, consult with the appropriate regulatory agencies and inspection authorities to ensure compliance. • Install the ONT in accordance with national and local electric codes in order to meet all applicable requirements. Consult a qualified electrical consultant. EMI Precautions Canada This Class B digital apparatus meets all requirements of the Canadian interference-causing equipment regulations. Cet appareil numérique de la classe B respecte toutes les exigences du règlement sur le matérial brouilleur du Canada. Zhone 2800 Series FiberJACK ONT Hardware Installation Guide 13 About This Guide 14 Zhone 2800 Series FiberJACK ONT Hardware Installation Guide ZHONE 2800 SERIES FIBERJACK ONT This chapter describes the 2800 Series of zNIDs. It includes the following sections: • Overview, page 15 • Zhone 2800 Series FiberJACK ONT features, page 18 • Zhone 2800 Series FiberJACK ONT models, page 18 • Zhone 2800 Series FiberJACK ONT specifications, page 21 • Zhone 2800 Series FiberJACK ONT dimensions, page 27 • Zhone 2800 Series FiberJACK ONT LEDs, page 32 • Logging in to the 2800 Series ONT, page 35 Overview The Zhone 2800 Series FiberJACK ONT zNID (Zhone Network Interface Device) is a family of indoor residential GPON or Gigabit Ethernet fiber based devices which are standards based Consumer Premises Equipment (CPE) designed for advanced triple-play deployments. These indoor models in Zhone's zNID product line of ONT's can be installed directly in the wall using standard size electrical wall outlet boxes. The Zhone 2800 Series FiberJACK ONTs may be provisioned using the same intuitive Web interface and CLI as the Zhone 2400, 2600 and 4200 Series ONTs, as well as through USP (Unified Service Provisioning), the Zhone Network Management System (ZMS), or using a TR-069-compliant ACS. The GPON ONTs comply with standard OMCI definitions and are manageable at remote sites supporting the full range of FCAPS functions including supervision, monitoring and maintenance. More information about management capabilities see the Zhone zNID Configuration Guide. Zhone 2800 Series FiberJACK ONT Hardware Installation Guide 15 Zhone 2800 Series FiberJACK ONT Zhone 2800 Series FiberJACK ONT components The Zhone 2800 Series FiberJACK ONTs are designed for wall mounting onto a standard 20 cubic inch electrical outlet box. Figure 1: LED indicators and buttons on the 280x FiberJACK ONT Figure 2: LED indicators and buttons on the 281x FiberJACK ONT 16 Zhone 2800 Series FiberJACK ONT Hardware Installation Guide Overview Note that the 281x models do not have a power on/off switch Figure 3: LED indicators on GigE ports See Table 6, Zhone 2800 Series FiberJACK ONT GigE LEDS on page 34. Zhone 2800 Series FiberJACK ONT Hardware Installation Guide 17 Zhone 2800 Series FiberJACK ONT Zhone 2800 Series FiberJACK ONT features All 2800 Series ONTs are designed for indoor use. The 2800 Series share a common SW architecture with the 2400, 2600, 4200 and 9000 series of zNIDs, including the same intuitive Web interface and command line interface. This section covers: • Zhone 2800 Series FiberJACK ONT models • Zhone 2800 Series FiberJACK ONT specifications • Zhone 2800 Series FiberJACK ONT dimensions Zhone 2800 Series FiberJACK ONT models Other than the color stripe for the SC connector which is not visible with the cover on, the GE and GPON models look the same. Figure 4: Zhone 2800 Series FiberJACK ONT Caution: To ensure adequate ventilation, nothing should be placed against the Zhone 2800 Series FiberJACK ONT. Enough air space, at least one inch should be left around each side of the ONT. 18 Zhone 2800 Series FiberJACK ONT Hardware Installation Guide Zhone 2800 Series FiberJACK ONT models Figure 5: Zhone 2800 Series FiberJACK ONT models GPON models The GPON models have the following interfaces: Table 2: GPON models and interfaces Model Description ZNID-GPON-2804P-WAC GPON ONT, FiberJack, 4 GE w/PoE, AC powered ZNID-GPON-2804P-WDC GPON ONT, FiberJack, 4 GE w/PoE, DC powered zNID-GPON-2812P-WAC GPON WAN, FiberJack, 2xGE(PoE), 1xPOTS, AC powered zNID-GPON-2812P-WDC GPON WAN, FiberJack, 2xGE(PoE), 1xPOTS, DC powered zNID-GPON-2813P-WAC GPON WAN, FiberJack, 2xGE(PoE), 1xPOTS, RFV, AC powered zNID-GPON-2813P-WDC GPON WAN, FiberJack, 2xGE(PoE), 1xPOTS, RFV, DC powered zNID-GPON-2814P-WAC GPON WAN, FiberJack, 2xGE(PoE), 1xPOTS, WiFi, AC powered zNID-GPON-2814P-WDC GPON WAN, FiberJack, 2xGE(PoE), 1xPOTS, WiFi, DC powered Zhone 2800 Series FiberJACK ONT Hardware Installation Guide 19 Zhone 2800 Series FiberJACK ONT Table 2: GPON models and interfaces Model Description zNID-GPON-2815P-WAC GPON WAN, FiberJack, 2xGE(PoE), 1xPOTS, RFV, WiFi, AC powered zNID-GPON-2815P-WDC GPON WAN, FiberJack, 2xGE(PoE), 1xPOTS, RFV, WiFi, DC powered Gigabit Ethernet models The Gigabit Ethernet models have the following interfaces: Table 3: Gigabit Ethernet models and interfaces 20 Model Description ZNID-GE-2804P-WAC Active Ethernet ONT (GE Uplink), FiberJack, 4 GE W/PoE, AC powered ZNID-GE-2804P-WDC Active Ethernet ONT (GE Uplink), FiberJack, 4 GE W/PoE, DC powered zNID-GE-2812P-WAC Active Ethernet ONT (GE Uplink), FiberJack, 2xGE(PoE), 1xPOTS, AC powered zNID-GE-2812P-WDC Active Ethernet ONT (GE Uplink), FiberJack, 2xGE(PoE), 1xPOTS, DC powered zNID-GE-2814P-WAC Active Ethernet ONT (GE Uplink), FiberJack, 2xGE(PoE), 1xPOTS, WiFi, AC powered zNID-GE-2814P-WDC Active Ethernet ONT (GE Uplink), FiberJack, 2xGE(PoE), 1xPOTS, WiFi, DC powered Zhone 2800 Series FiberJACK ONT Hardware Installation Guide Zhone 2800 Series FiberJACK ONT models Zhone 2800 Series FiberJACK ONT specifications The possible interfaces and number of interfaces depend on the specific model, see Zhone 2800 Series FiberJACK ONT models on page 18 for a list of models and their interfaces. Table 4: Zhone 2800 Series FiberJACK ONT common specifications Specifications Values Dimensions Inside wall outlet portion (all models) 2.75 in (70 mm) high x 1.75 in (45 mm) wide x 1.25 in (32 mm) deep Outside wall outlet portion • zNID 280x models 5.7 in (145 mm) high x 4 in (102 mm) wide x 1.2 in (31 mm) deep. • zNID 281x models 7.1 in (182 mm) high x 5.5 in (140 mm) wide x 1.2 in (29 mm) deep. Weight • 280x models 1 lb (0.45 kg) • 281x models 1.2 lb (0.55 kg) Operating temperature 0°C to +40°C (32°F to +104°F) Storage temperature -20° C to +85° C (-4° F to 185° F) Humidity 5% to 95% (non-condensing) Zhone 2800 Series FiberJACK ONT Hardware Installation Guide 21 Zhone 2800 Series FiberJACK ONT Table 4: Zhone 2800 Series FiberJACK ONT common specifications (Continued) Specifications Values Power • AC models – 2804P - 100-240 VAC 50/60 Hz - Max Power = 40W (ONT + 20W PoE load) - Max Power = 12W (ONT only) – 2810P Input Voltage: 90 to 240 VAC, 50-60 Hz Input Power: 35W (10W ONT plus 15W PoE load) Input Power: 10W (ONT only) • DC models – 2804P - 48 VDC (nom.) - Max Power = 40W (ONT + 20W PoE load) - Max Power = 10W (ONT only) – 2810P Input Voltage: 36 to 56 VDC Input Power: 30W (10W ONT plus 15W PoE load) Input Power: 10W (ONT only) 22 Zhone 2800 Series FiberJACK ONT Hardware Installation Guide Zhone 2800 Series FiberJACK ONT models Table 4: Zhone 2800 Series FiberJACK ONT common specifications (Continued) Specifications Values Interfaces Uplinks: • • GPON: – SC/APC connector – Full ITU-T G.984 compliance – 1310nm Tx (Upstream) – 1490nm Rx (Downstream) – Fixed SFF optics – Tx (Upstream) line rate 1.25 Gbps – Tx Launch Power: +0.5 to +5.0 dBm – Rx (Downstream) line rate: 2.5 Gbps – Rx Receiver Sensitivity: -28 dBm – Rx Input Power Overload: -8 dBm – Dying gasp support GE: – SC/UPC connector – 1310nm Tx (Upstream) – 1490 nm Rx (Downstream) – Fixed SFF optics – Tx data rate 1.0 Gbps – Tx Launch Power: -8.0 to -2.0 dBm – Rx data rate: 1.0 Gbps – Rx Receiver Sensitivity: -23 dBm – Rx Input Power Overload: -2 dBm Customer facing interfaces (Depends on model): – GE ports – RJ-45 Jacks – 2 or 4 x 10/100/1000 Base-T ports – Meets IEEE 802.3 specifications – Auto-MDI/MDIX and auto speed supported – Per-port Link/Activity, Speed, and PoE status indicators – PoE support on all ports – Max 20W PoE load per ONT (2804P models) – Max 15W PoE load per ONT (281xP models) – POTS interfaces (RJ11) – Wi-Fi interface (Dual 802.11b/g/n) – Coaxial interface (RF video overlay (47–870MHz)) Zhone 2800 Series FiberJACK ONT Hardware Installation Guide 23 Zhone 2800 Series FiberJACK ONT Table 4: Zhone 2800 Series FiberJACK ONT common specifications (Continued) Specifications Values Standards Support • • • • • • • • • • • ITU-T G.984 compliant (GPON) • • • • • SIP (RFC 3261) • Various CLASS services — Caller ID, Call Waiting, Call Forwarding, Call Transfer, etc. • • • T.30 and T.38 Fax • • • • • • • • 2x2 MIMO • • 64 bit and 128 bit WEP support • • IGMP multicast POTS (Voice) Support Wireless (WiFi) Support IPTV 24 IEEE 802.3 Ethernet IEEE 802.1q/p VLANS IEEE 802.3u Fast Ethernet IEEE 802.3ab 1000Base-T 802.3at compliant 802.1x (specific models) IEEE 802.3z Gigabit Ethernet IEEE 802.1d Bridging IEEE 802.3u 10/100 Base-TX (Ethernet I/F) K.20 Surge Immunity MGCP 5 REN per line, balanced Ring at 60V RMS, DTMF dialing Multiple voice codec: G.711 (u/a-law), G.726, G.729 (A and B) Echo Canceling, Voice Activity Detection (VAD), Comfort Noise Insertion (CNI) G.711 fallback for FAX Pulse metering Antenna: 4dBi for 2.4GHz; 6dBi for 5GHz Max WiFi power: 37mW; radio band – selectable 2.4 GHz or 5.0GHz max number of subscribers: 16 per SSID SSID support: 4 1:1 mapping of SSIDs to VLANs WEP, WPA-PSK, WPA2-PSK (AES, TKIP) 802.1x MAC address filtering IGMPv2 snooping Zhone 2800 Series FiberJACK ONT Hardware Installation Guide Zhone 2800 Series FiberJACK ONT models Table 4: Zhone 2800 Series FiberJACK ONT common specifications (Continued) Specifications Values Protocol Support • • • • • GPON – ITU-T G.984 (GPON) – 32 T-CONTS per device – 32 GEM Ports per device – Activation with automatic discovered SN and password in conformance with ITU-T G.984.3 – AES-128 Decryption with key generation and switching – FEC (Forward Error Correction) – 802.1p mapper service profile on U/S – Support for Multicast GEM Port QoS QoS – Ethernet bridging/switching per IEEE 802.1D/802.1Q – Traffic management (priority queuing) – QoS with support for IEEE 802.1p + DSCP VLANS VLANs – Per port IEEE 802.1Q VLAN ID processing – All VLAN IDs supported – VLAN tagging/untagging – VLAN Stacking (QinQ) – VLAN Switching Layer 2 – 802.3n flow control – Automatic MAC learning and aging – Unlimited # of MAC addresses for OMCI-configured flows – Support for up to 4,096 MAC addresses for RG traffic flows – Broadcast storm control – LLDP-MED IP Routing and Firewall – PPPoE – NAT/NAPT – Port forwarding – DHCP Server – DNS Server – UPnP Zhone 2800 Series FiberJACK ONT Hardware Installation Guide 25 Zhone 2800 Series FiberJACK ONT Table 4: Zhone 2800 Series FiberJACK ONT common specifications (Continued) Specifications Values Management • • • • • • • ZMS (Zhone Management System) • • CE • • FCC Part 15, Class B Regulatory Compliance 26 OMCI Web UI Command Line Interface SNMP USP (Unified Service Provisioning) TR-069 UL FDA 21CFR1040 Zhone 2800 Series FiberJACK ONT Hardware Installation Guide Zhone 2800 Series FiberJACK ONT dimensions Zhone 2800 Series FiberJACK ONT dimensions Figure 6: Zhone 280x Series FiberJACK ONT dimensions Zhone 2800 Series FiberJACK ONT Hardware Installation Guide 27 Zhone 2800 Series FiberJACK ONT Figure 7: Zhone 281x Series FiberJACK ONT dimensions 28 Zhone 2800 Series FiberJACK ONT Hardware Installation Guide Zhone 2800 Series FiberJACK ONT controls and switches Zhone 2800 Series FiberJACK ONT controls and switches This section describes the 2800 Series FiberJACK ONT controls: • Power On/Off Switch • Reset Button • LED Mode Selector Switch • Tamper Detection Switch Figure 8: 280x Series FiberJACK ONT controls and switches Zhone 2800 Series FiberJACK ONT Hardware Installation Guide 29 Zhone 2800 Series FiberJACK ONT Figure 9: 281x Series FiberJACK ONT controls and switches Power On/Off Switch zNID 280x models. The Power On/Off Switch is located on the left side of the 280x ONT faceplate. zNID 281x models. The Power On/Off Switch is located on the right side, above the Reset Switch but is under the faceplate. This switch is primarily for Installation Technicians, providing them with an easy means to control power on/off for the unit during the installation or troubleshooting process while the faceplate is removed. A slot on the left side of the faceplate provides a means to power on/off the unit without having to remove the faceplate using a pen cap, paper clip or small slot screwdriver. 30 Zhone 2800 Series FiberJACK ONT Hardware Installation Guide Zhone 2800 Series FiberJACK ONT controls and switches Reset Button The unit can be reset by depressing the Reset Button for less than 10 seconds. Holding the Reset Button until all the LEDs illuminate (approximately 10 seconds) will reset the configuration to factory defaults and also reboot the device. zNID 280x Models The Reset Button is accessible through a hole on the top of the unit (with the Faceplate installed). zNID 281x Models The Reset Button is accessible through a hole on the right side of the unit (with the Faceplate installed). LED Mode Selector Switch The LED Mode Selector Switch is used to toggle through the three LED operating modes to select the desired behavior. • Day Mode (All LEDs enabled) • Night Mode (WAN LED and Alarm LED ONLY) • Off Mode (All LEDs disabled) The LED mode is written to FLASH after a 3 second de-bounce delay to ensure that the configured LED state is retained over a power cycle. The button needs to be depressed for 10 seconds, to switch between the modes. zNID 280x Models The switch is located on the left side of the faceplate, above the Power switch. zNID 281x Models The switch is located on the right lower side of the faceplate. Tamper Detection Switch A Tamper Detection Switch is used to detect if the faceplate has been removed. Upon detection, an SNMP Trap is generated and a Syslog Event captured to record the date and time of the faceplate removal. The red Alarm LED will not be lit, as this is a “silent alarm” event. Zhone 2800 Series FiberJACK ONT Hardware Installation Guide 31 Zhone 2800 Series FiberJACK ONT Zhone 2800 Series FiberJACK ONT LEDs Figure 10: zNID-GPON-280x LEDS Figure 11: zNID-GPON-281x LEDS Table 5: zNID-GPON-2800 LEDs LED Name Color Behavoir Indicates CONFIG Green Solid On Unit is provisioned (provisioning is complete) Green Rapid blink (10/sec) OMCI provisioning is in progress* Green Slow blink (1/sec) SNMP provisioning is in progress* N/A Off Unit is not provisioned Green Solid On Ranged successfully Green: Slow blink (1/sec) Ranging in progress N/A Off Not ready for ranging or not provisioned Red Solid On Major alarm is active Red Red: 50% cycle: EZ Touch actions pending -- SW or Config update required WAN ALARM (1 sec Rapid Blink/1 sec Off) N/A 32 Off Zhone 2800 Series FiberJACK ONT Hardware Installation Guide Normal operation on AC power Zhone 2800 Series FiberJACK ONT LEDs Table 5: zNID-GPON-2800 LEDs LED Name Color Behavoir Indicates STATUS Green Heartbeat (1 short blink every 5 seconds) Normal Operation Green Rapid blink Unit has been reset to Factory Defaults / is unconfigured (10/sec) WIFI VOICE Green Alternating fast blinking (1 sec rapid blink/1 sec off) EZ Touch communications in process Green Slow blink (2/second) Remote Mgt Access (OMCI, SNMP, HTTP, Telnet, or TR-069) Green Solid On Reboot or restart in process N/A Off Power off Green Solid On WiFi is enabled by not actively sending/receiving traffic Green Fast Blink -- variable rate WiFi traffic is actively being sent or received N/A Off WiFi is disabled Green Solid On Voice is Registered but idle Green Slow Blink -- 2 pulses per sec Voice is Active (off-hook, or incoming call is Ringing) ( .25 sec ON / .25 sec OFF ) N/A Off Voice is not Registered * Unified Service Provisioning uses OMCI and SNMP to provision the ONT depending on the feature being provisioned. Zhone 2800 Series FiberJACK ONT Hardware Installation Guide 33 Zhone 2800 Series FiberJACK ONT Figure 12: Zhone 2800 Series FiberJACK ONT GigE LEDS Table 6: Zhone 2800 Series FiberJACK ONT GigE LEDS LED Name Color Indicates Right LED Off 10 BaseT Yellow 100 Base T Green 1000 Base T Left LED Off Link Down or Port Disabled (LINK/ ACTIVITY Yellow: Solid on Link up, no Tx/Rx traffic Yellow: Blinking Link up, Tx/Rx traffic present Green: Solid on Link up with PoE Power being delivered, no Tx/Rx traffic Green: Blinking Link up with PoE Power being delivered, Tx/Rx traffic present (SPEED) 34 Zhone 2800 Series FiberJACK ONT Hardware Installation Guide Logging in to the 2800 Series ONT Logging in to the 2800 Series ONT This section describes logging into the FiberJACK ONT locally with a browser or CLI (telnet) using the subscriber facing LAN port, GE1. This section assumes the ONT is in a default state with factory settings, including the default factory IP address. Figure 13: Log into GigE port to reach the Web UI or CLI on the zNID Note: The 2800 Series ONT may be managed by other means, however this guide only describes local management. Note: If, after powering on, the FiberJACK ONT does not respond to the browser, telnet or a ping test, reset the ONT to make sure the ONT is in a known state. See Reset Button, page 31. To login with a browser: Connect an Ethernet cable from your computer to a GigE port on the ONT. Launch a browser and point it to 192.168.1.1. Enter the username and password. The default username/password is admin/zhone. To login with a telnet session: Connect an Ethernet cable from your computer to a GigE port on the ONT. Launch a telnet session and point it to 192.168.1.1. Enter the username and password. The default username/password is admin/zhone. Zhone 2800 Series FiberJACK ONT Hardware Installation Guide 35 Zhone 2800 Series FiberJACK ONT 36 Zhone 2800 Series FiberJACK ONT Hardware Installation Guide ZHONE 2800 SERIES FIBERJACK ONT INSTALLATION This chapter describes the procedures for installing the FiberJACK ONT. The FiberJACK ONT comes complete with all hardware for installation into a standard single-gang electrical wallbox with 3.25 inches between vertical mounting holes. A metal wallbox should be used. This section applies to FiberJACK ONTs that are AC-powered or DC powered. It includes the following sections: • Install the FiberJACK ONT, page 38 • Installation precautions, page 39 • Power connections, page 50 • Manage the optical cable, page 54 • Fiber handling, page 54 • Testing optical power, page 54 • Connect to network cautions, page 55 Zhone 2800 Series FiberJACK ONT Hardware Installation Guide 37 Zhone 2800 Series FiberJACK ONT Installation Install the FiberJACK ONT This section describes the procedures for installing the FiberJACK ONT. The FiberJACK ONT comes complete with all hardware for installation into a standard single-gang electrical wallbox with 3.25 inches between vertical mounting holes. A metal wallbox should be used. This installation guide applies to FiberJACK ONTs that are AC powered or DC powered. zNID 2800P series FiberJACK ONT installation overview Figure 14: Exploded view of FiberJACK ONT installation with 3 pin connector Select location for the FiberJACK ONT Provide power to the wallbox There are different power connection steps depending on whether connecting to AC power, DC power from PoE, or two-wire DC power. 38 Provide fiber to the wallbox Connect power and the fiber Secure the FiberJACK ONT to the wallbox Attach the FiberJACK ONT faceplate Connect subscriber services Zhone 2800 Series FiberJACK ONT Hardware Installation Guide Install the FiberJACK ONT Installation precautions WARNING! Installing electrical wires, especially for the AC installations, may be hazardous and could lead to serious injury or possibly death. Disconnect power before conducting the installation. Take all proper precautions or have a qualified electrician perform the tasks for installing electrical wiring. Maximum operating temperature should not exceed the range of 0° C to 40° C (32° F to 104° F). Ensure that proper cable grades are used for all system and network connections. For best results, use the cables and connectors recommended in this document. Connect the system to the power supply circuit as described in this document. Before making fiber connections, be sure that the optical cable fiber tips and components are clean and free of dust and debris. Follow established cleaning procedures if required. Resilient, Bend-Insensitive Fiber Optic Cabling such as the Corning 4.8mm ClearCurve™ ZBL Drop Cable must be run to the box. This type of fiber has <0.1dB loss for a 5mm radius loop. Note: Sharp bends in non-bend-insensitive fiber cables create undesirable optical attenuation or loss. A minimum bend radius of 30 mm (1.2 in) is recommended for stripped fiber so non-bend-insensitve fiber is not sufficient for use with the Zhone 2800 Series FiberJACK ONT. Zhone 2800 Series FiberJACK ONT Hardware Installation Guide 39 Zhone 2800 Series FiberJACK ONT Installation zNID 2800P series FiberJACK ONT installation procedure Select location for the FiberJACK ONT The location for the FiberJACK ONT should be free of dust and moisture. The area in front of the FiberJACK ONT should be left open so that there is sufficient ventilation for the ONT. Select one of the mounting options, depending on the location for the wallbox: – Add a new wallbox and AC circuit. This method may involve the most construction, but provides the greatest flexibility. – Add a new wallbox adjacent to (within 6" of) an existing outlet. This method is the preferred and simpler solution for most commercial and hospitality installations when using an "old-work" wallbox. – Replace an existing AC outlet with FiberJACK ONT. This method may be the simplest installation if the location is suitable and the wallbox is not too full of splices and connectors. – Add a new wallbox and DC circuit. The steps presented for the DC powered installation do not require a licensed electrician, due to the low voltages involved. Provide power to the wallbox Depending on the power source and wallbox combination use the following options: – Providing power to AC powered ONTs, new wallbox, page 46 – Providing power to AC powered ONTs, replacing an outlet in an existing wallbox, page 48 – Providing power for DC powered ONTs, page 49 WARNING! Installing electrical wires, especially for the AC installations, may be hazardous and could lead to serious injury or possibly death. Disconnect power before conducting the installation. Take all proper precautions or have a qualified electrician perform the tasks for installing electrical wiring. Provide fiber to the wallbox Run resilient bend-insensitive fiber optic cabling (such as the Corning 4.8mm ClearCurve™ ZBL Drop Cable) to the box Route the fiber as desired for the final installation, and then cut the fiber for proper termination length The terminated fiber needs to extend 6" (150mm) from the wall. 40 Zhone 2800 Series FiberJACK ONT Hardware Installation Guide Install the FiberJACK ONT The fiber must then be properly terminated with an SC/APC connector for GPON ONT models or with an SC/UPC connector for GE ONT models. Connect power and the fiber Remove the wallbox cover (if present) Remove the faceplate from the base assembly of the FiberJACK ONT by unscrewing the two security (hex-pin) screws with a #T10 Security Torx screwdriver or equivalent Slide the faceplate straight down (toward the GE LAN ports) approximately 1/4" until you feel the two retention latches un-snap Verify that the GE LAN port holes in the faceplate are clear of the RJ45 connectors, so that the faceplate may be lifted straight up and off Connect Power to the FiberJACK ONT – For AC powered ONTs Always disconnect power before conducting the installation on AC circuits. Put the ONT Power Switch on the lower left side into the OFF (down) position using a pen cap, paper clip or small slot screwdriver. Connect the ONT Power Pigtail (attached to the FiberJACK ONT) to the AC Power Pigtail coming from the wallbox. Fold and tuck the excess wiring back into the wallbox – For DC powered ONTs Put the ONT Power switch on the lower left side into the Off (down) position using a pen cap, paper clip, or small slot screwdriver. PoE source: When powering from a PoE source, plug the terminated CAT5 or CAT6 cable into the RJ45c connector on the back of the FiberJACK ONT, and fold the excess cable into the wallbox. Zhone 2800 Series FiberJACK ONT Hardware Installation Guide 41 Zhone 2800 Series FiberJACK ONT Installation 2-wire DC source: When powering from a 2-wire DC source, strip the insulation back from the ends of the 2-wire DC cable to expose about 15mm (0.6") of bare copper wire. Connect these wires to the 2-pin connector on the back of the FiberJACK ONT. Check that the polarity is correct before connecting the wires. The positive terminal is on the right (closest to the RJ-45 connector). Note: There is protection for the FiberJACK ONT from reversed polarity, however the FiberJACK ONT will not power up if the polarity is reversed. zNID 281x models: Remove fiber area cover. Route the fiber pigtail from the wallbox through the notch in the circuit board in the lower right of the FiberJACK ONT (see Figure 15, 280x Models: Thread the fiber cable through the notch in the circuit board.) Figure 15: 280x Models: Thread the fiber cable through the notch in the circuit board. 42 Zhone 2800 Series FiberJACK ONT Hardware Installation Guide Install the FiberJACK ONT Figure 16: 281x Models: Thread the fiber cable through the notch in the circuit board. Other than the connector type, fiber installation is the same for GPON and GE models. See Manage the optical cable, page 54 and page 55 for more information. Remove the dust covers from the SC connector on the FiberJACK ONT, and from the SC/APC or SC/UPC termination on the fiber pigtail. Insert the fiber pigtail securely into the SC connector on the FiberJACK ONT zNID 281x models: Replace fiber area cover. Make sure the fiber does not get pinched when positioning the FiberJACK ONT base assembly into the wallbox over the wallbox mounting holes. Secure the FiberJACK ONT to the wallbox – For mounting into a plastic wallbox, the two self-tapping screws (included) are used. – For mounting into a metal wallbox, the two machine-thread screws (included) are used. Insert one mounting screw into the upper mounting hole of the FiberJACK ONT base assembly and turn it clockwise several revolutions, but do not completely tighten it. Leaving the screw loose will be sufficient to hold the ONT base assembly in place while powering up the ONT and verifying that it can range and connect to the OLT. Provide power to the circuit (via breaker or fuse) Turn on the Power Switch (lower left side of the FiberJACK ONT) by sliding it to the ON (up) position. Zhone 2800 Series FiberJACK ONT Hardware Installation Guide 43 Zhone 2800 Series FiberJACK ONT Installation Verify that the red Alarm LED turns on, and remains on until the GPON link successfully ranges or until the active Ethernet WAN connection is up (for Active Ethernet ONTs) If the GPON link does not range (or the GE link does not come up) troubleshoot the installation in conjunction with the staff responsible for OLT and ONT provisioning. Once the Alarm LED has turned OFF, insert a second mounting screw into the lower mounting hole of the FiberJACK ONT base assembly and tighten it completely while ensuring that the FiberJACK ONT is properly leveled. Tighten the top mounting screw so the FiberJACK ONT is securely fastened to the wall. Attach the FiberJACK ONT faceplate Place the FiberJACK ONT faceplate over the mounted ONT base assembly and push upwards approx 1/4" until you feel the two retention latches snap together. Secure the faceplate using the two security (hex-pin) screws with a #T10 Security Torx screwdriver or equivalent. Connect subscriber services Connect subscriber Ethernet services The FiberJACK provides up to four GE LAN ports using RJ45 modular jacks for Ethernet connections. These Ethernet connections can be used to deliver any packet services including IPTV, data, and VoIP. For Ethernet services, connect a Category 5 or a Category 6 cable to an RJ45 interface as shown in Figure 17. Figure 17: The RJ-45 Ethernet ports. 44 Zhone 2800 Series FiberJACK ONT Hardware Installation Guide Install the FiberJACK ONT If the cable is not terminated, follow local practices to attach an RJ-45 connector. Connect telephone (POTS) service Figure 18: The voice port (POTS). Plug the line from the telephone into the POTS port. Connect coaxial service Figure 19: The TV port (coaxial). Locate the premises’ coaxial cable. If the cable is not terminated, follow local practices to attach a coaxial connector. Screw the coaxial connector to the TV coaxial port. Zhone 2800 Series FiberJACK ONT Hardware Installation Guide 45 Zhone 2800 Series FiberJACK ONT Installation Providing power to the wallbox WARNING! Installing electrical wires, especially for the AC installations, may be hazardous and could lead to serious injury or possibly death. Disconnect power before conducting the installation. Take all proper precautions or have a qualified electrician perform the tasks for installing electrical wiring. Providing power to AC powered ONTs, new wallbox For AC powered ONTs, new wallbox 46 Turn off any electricity running to the wallbox circuit. Check that the wallbox is mounted securely (new or old work style wallbox). A plastic or a metal wallbox can be used. Non-metallic ("Romex") or flexible metal-clad ("BX") AC cabling should be used per local electrical code requirements. Strip back the outer sheath of the AC cable wires in the wallbox, exposing the three conductors (Hot, Neutral, and Ground) inside. Trim the length of the Hot, Neutral, and Ground conductors from the outlet box to have approximately 4 to 5 inches of working length. Strip the insulation back from the ends of the Hot, Neutral and Ground conductors to expose about 15mm (0.6") of bare copper wire. Add two lengths of heat-shrink tubing — 30mm and 40mm diameter — over the end of the wires and slide back to make the connection. Have the larger diameter piece be closer to the connector. Zhone 2800 Series FiberJACK ONT Hardware Installation Guide Providing power to the wallbox Connect the female, 3-pin, terminal-style connector to the stripped ends of the AC wires prepared in Step 6. Make sure that the three AC wires are connected to the correct pins by checking the wiring chart shown in Power connections on page 50. Pull the heat-shrink tubing down which is closest to the connector and pull it down and stretch it so it will cover the terminal screws, then apply appropriate heat to shrink the larger diameter piece of tubing to the connector. Pull the second smaller diameter heat-shrink tubing down over the end of the other molded tubing, then apply appropriate heat to shrink the smaller diameter piece of tubing over the end of the larger diameter piece to present a fully-insulated AC Power pigtail connection. This connection can be pushed into the wallbox and a wallbox cover added if the FiberJACK ONT will be installed at a later time. Note: The AC Powered ONTs have an ONT Power Pigtail with a male connector designed to connect to the female AC Power Pigtail connector. Zhone 2800 Series FiberJACK ONT Hardware Installation Guide 47 Zhone 2800 Series FiberJACK ONT Installation Providing power to AC powered ONTs, replacing an outlet in an existing wallbox Turn off any electricity running to the wallbox. Check that the outlet has sufficient space available inside for mounting the FiberJACK ONT The wallbox should have 3" (70mm) of unimpeded depth to allow for splices and connectors. Partially remove the outlet from the wallbox, disconnect the AC wires attached to it, and label them for identification if necessary. These wires need to have approximately 4 to 5 inches of working length. If necessary, strip the insulation back from the ends of these Hot, Neutral and Ground wires to expose about 15mm (0.6") of bare copper wire. Add two lengths of heat-shrink tubing — 30mm and 40mm diameter — over the end of the wires and slide back to make the connection. Have the larger diameter piece be closer to the connector. Connect the female, 3-pin, terminal-style connector to the stripped ends of the AC wires prepared in Step 4. Make sure that the three AC wires are connected to the correct pins by checking the wiring chart shown in Power connections on page 50. 48 Pull the heat-shrink tubing down which is closest to the connector and pull it down and stretch it so it will cover the terminal screws, then apply appropriate heat to shrink the larger diameter piece of tubing to the connector. Zhone 2800 Series FiberJACK ONT Hardware Installation Guide Providing power to the wallbox Pull the second smaller diameter heat-shrink tubing down over the end of the other molded tubing, then apply appropriate heat to shrink the smaller diameter piece of tubing over the end of the larger diameter piece to present a fully-insulated AC Power pigtail connection. This connection can be pushed into the wallbox and a wallbox cover added if the FiberJACK ONT will be installed at a later time. Note: The AC powered ONTs have an ONT Power Pigtail with a male connector designed to connect to the female AC Power Pigtail connector. Providing power for DC powered ONTs The DC powered FiberJACK ONT may be powered from a PoE source, or from a 2-wire DC feed. • Provide power from a Power over Ethernet source When powering from a PoE source, run a CAT5 or CAT6 cable from the DC power source into the wallbox. If the PoE cable is not terminated, follow local practices to attach an RJ-45 connector. See RJ-45 DC Power over Ethernet connection on page 52 for pinout information. The terminated PoE cable fiber needs to extend 6" (150mm) from the wall. • When powering from a 2-wire DC source, run a low-voltage 2-wire cable from the DC power source into the wallbox. See 2 pin DC connection on page 52 for information. Zhone 2800 Series FiberJACK ONT Hardware Installation Guide 49 Zhone 2800 Series FiberJACK ONT Installation Power connections • For 115/120VAC connections • For 115/120VAC connections with wire nuts • For 220/240VAC connections • For two pin DC connections • For RJ-45 Power over Ethernet WARNING! Installing electrical wires, especially for the AC installations, may be hazardous and could lead to serious injury or possibly death. Disconnect power before conducting the installation. Take all proper precautions or have a qualified electrician perform the tasks for installing electrical wiring. 3 pin ONT power pigtail for 115/120VAC connections Figure 20: 3 pin ONT power pigtail Table 7: For 115/120VAC connections Wallbox Side 50 Connector Pin Name Typical Color Neutral White Ground Hot or Live FiberJACK Side Name Color AC-N White with blue stripe Green 2 (center) GND Green with yellow stripe Black AC-L Black with brown stripe Zhone 2800 Series FiberJACK ONT Hardware Installation Guide Power connections 3 wire ONT power for 115/120VAC connections using wire nuts Figure 21: 3 pin ONT power pigtail Table 8: For 115/120VAC connections with wire nuts Wallbox Side FiberJACK Side Name Typical Color Name Color Neutral White AC-N White with blue stripe Ground Green GND Green with yellow stripe Hot or Live Black AC-L Black with brown stripe 3 pin ONT power pigtail for 220/240VAC connections Figure 22: 3 pin ONT power pigtail for 220/240VAC Table 9: For 220/240VAC connections Wallbox Side Connector Pin Name Typical Color Neutral Blue Ground Line FiberJACK Side Name Color AC-N White with blue stripe Green with yellow stripe 2 (center) GND Green with yellow stripe Brown or black AC-L Black with brown stripe Zhone 2800 Series FiberJACK ONT Hardware Installation Guide 51 Zhone 2800 Series FiberJACK ONT Installation 2 pin DC connection Figure 23: 2 pin DC connection Table 10: For two pin DC connections Wallbox Side Terminal FiberJACK ONT Name Typical Color Name + 48V any +VDC +48V Return any -VDC RJ-45 DC Power over Ethernet connection The Power over Ethernet port on the back of the 2804P base assembly only provides power to the ONT. It is NOT an Ethernet LAN or WAN port. Figure 24: RJ-45 Power over Ethernet connection 52 Zhone 2800 Series FiberJACK ONT Hardware Installation Guide Power connections Table 11: For RJ-45 Power over Ethernet Pins(1) Name Definition(2) 2-pair Mode A 2-pair Mode B 4-pair 1 and 2 Pair 1 DC in DC in 3 and 6 Pair 2 Return Return 4 and 5 Pair 3 DC in DC in 7 and 8 Pair 4 Return Return (1) RJ-45 pins shown are connected together within the 2804P ONT. (2) The polarity of DC In with respect to Return can be positive or negative. Zhone 2800 Series FiberJACK ONT Hardware Installation Guide 53 Zhone 2800 Series FiberJACK ONT Installation Manage the optical cable When making a fiber optic connection, avoid touching the fiber cable ends to the outside of the mating connector. Touching can contaminate the connectors. Fiber handling Before making any connections, be sure that the optical cable fiber tips and components are clean and free of dust and debris. Testing optical power Table 12, Table 13, and Table 14 indicate various optical thresholds for the ONTs. Table 12: Optical thresholds for the zNID-GPON-2800 Series ONTs Parameter 1490 nm (Data Downstream) Damage Level +5 dBm Optical Overload -8 dBm Minimal Optical Signal -28 dBm Mid Range Optical Value -17 dBm Table 13: Optical thresholds for the zNID-GE-2810 Series ONTs Parameter Active Ethernet Damage Level +5 dBm Optical Overload -2 dBm Minimal Optical Signal -23 dBm Mid Range Optical Value -12 dBm Table 14: RF Overlay optical thresholds for the zNID-GPON-2810 Series ONTs 54 Parameter 1550 nm (RF Video Overlay Downstream) Damage Level +5 dBm Linear Operating Range -8.0 dBm to +2.0 dBm Mid Range Optical Value -3.0 dBm Zhone 2800 Series FiberJACK ONT Hardware Installation Guide Connect to network cautions Connect to network cautions When connecting the SC connector from the electronics module to the SC connector in the zNID enclosure, observe the necessary precautions to decrease the risk of exposure to laser radiation. WARNING! Risk of eye damage. At all times when handling optical fibers, follow the safety procedures recommended by your company. Although Zhone optical products have a Class I certification, hazardous exposure to laser radiation can occur when fibers are connected, disconnected or broken. Handling of optical fibers without dust caps increases the risk of exposure. Exposure to either visible or invisible laser light can damage your eyes under certain conditions. Figure 25: The zNID-GPON-2800 models use fiber with an SC/APC connector (green) Zhone 2800 Series FiberJACK ONT Hardware Installation Guide 55 Zhone 2800 Series FiberJACK ONT Installation Figure 26: The zNID-GE-2800 models use fiber with an SC/UPC connector (blue) Note: To function properly the optical strength to the zNID should be between -8dBm and -28 dBm for GPON and between -2dBm and -23dBm for GE units. See page 54 for information. 56 Zhone 2800 Series FiberJACK ONT Hardware Installation Guide INDEX Numerics 280x Series FiberJACK ONT controls and switches 29 281x Series FiberJACK ONT controls and switches 30 AC power, 115/120VAC 50, 51 AC power, 220/240VAC 51 AC, providing power to ONT, existing wallbox 48 AC, providing power to ONT, new wallbox 46 Acronyms 7 APC 7 FiberJACK ONT 15 interfaces 23 model numbers 19 FiberJACK ONT Overview 15 Gigabit Ethernet models 20 GigE 7 GPON models 19 interfaces supported 23 IPTV 7 coaxial 45 Coaxial interface 23 components 16 Connect coaxial service 45 Connect subscriber Ethernet services 44 Connect telephone (POTS) service 45 Controls 29 controls and switches 29 LED displays on GigE ports 17 LED Mode Selector Switch 31 LED mode, Day Mode 31 LED mode, Night Mode 31 LED mode, Off Mode 31 LEDs 32 ALARM 32 CONFIG 32 STATUS 33 VOICE 33 WAN 32 WIFI 33 LEDs enabled 31 Logging in to the 28xx series zNID 35 login with a browser 35 login with telnet 35 Day Mode 31 DC power from PoE 52 DC power, 2 pin 52 Dimensions 27 Documentation, related 7 Dual 802.11b/g/n 23 Ethernet connection 44 Features 18 Fiber handling 54 MGCP 24 model numbers 19, 20 models 18 Night Mode 31 Zhone 2800 Series FiberJACK ONT Hardware Installation Guide 57 Index Off Mode 31 Optical power, testing 54 SIP 24 specifications 21 Style conventions 5 Switches 29 PoE 52 POTS 45 POTS interfaces 23 Power On/Off Switch 30 Power, providing 46 Power, providing, DC, Power over Ethernet 52 Providing power, AC 50, 51 Providing power, DC 52 Tamper Detection Switch 31 TV port 45 Typographical conventions 6 voice support 24 Reset Button 31 RF video overlay 23 RJ11 23 RJ-45 Ethernet ports 44 RJ-45 Jacks 23 SC/APC connector 55 SC/UPC connector 56 58 Warnings and Cautions explained 5 Wi-Fi interface 23 Zhone Network Interface Device 15 zNID 15 Ethernet connection 44 model numbers 20 voice support 24 Zhone 2800 Series FiberJACK ONT Hardware Installation Guide
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Page Mode : UseOutlines XMP Toolkit : 3.1-702 Producer : Acrobat Distiller 7.0.5 (Windows) Creator Tool : FrameMaker 6.0 Modify Date : 2015:08:19 18:29:39-07:00 Create Date : 2015:08:19 17:35:19Z Metadata Date : 2015:08:19 18:29:39-07:00 Format : application/pdf Title : zNID 28xx Hardware Installation Guide Creator : Zhone Technologies Document ID : uuid:d021b877-6307-4069-9e34-84c07bd1c6ee Instance ID : uuid:94a88b82-70d6-4e1f-8cb7-b5a825c3561a Page Count : 58 Author : Zhone TechnologiesEXIF Metadata provided by EXIF.tools