DIGI SINGAPORE TRKRF06 RF_CC2541 MODULE EXT User Manual DI 300SS Service Manual
Teraoka Weigh-System Pte Ltd. RF_CC2541 MODULE EXT DI 300SS Service Manual
User manual
COPYRIGHT © 2005 TERAOKA WEIGH-SYSTEM PTE LTD
USER MANUAL
WIRELESS RF DEVICE
RF_CC2541 Module EXT
TRK-RF-06
REVISION 1.0
Table of Content
i) Notice .............................................................................................................................. 1
ii) Safety Information ........................................................................................................... 2
iii) Safety Regulations .......................................................................................................... 3
1. General ..............................................................................................................................................................7
1.1 Product Features ............................................................................................................. 7
1.2 Operating Specification ................................................................................................... 7
2 Dimension ....................................................................................................................... 8
3. Label Information ............................................................................................................. 8
4. Interface .......................................................................................................................... 9
5. Revision Records ......................................................................................................................................... 10
- 1 -
i) Notice
DIGI®
The material contained in this document is proprietary and for information only and is subject to change without
notice. Teraoka Weigh-System assumes no responsibility for any errors or damages arising from
misinterpretation of any procedure.
Screen displays, operating procedures and supporting features might vary with different software version
releases.
This document shall not be reproduced whether in part or whole without the written consent from Teraoka
Weigh-System Pte Ltd.
Teraoka Weigh-System Pte Ltd
4, Leng Kee Road
#06-01 SIS Building
Singapore 159088
TRK-RF-06 User Manual
2
ii) Safety Information
The operator of the equipment shall comply with the safety and warning indications and procedures outlined in
this document. Teraoka Weigh-System Pte Ltd assumes no responsibility or liability for failure to comply with
these requirements.
For continued protection against fire hazard replace only with battery of same rating and type.
Avoid overloading the product beyond its rated maximum capacity
Trained and qualified personnel shall only carry out repair and servicing of product.
Disclaimer:
Specifications are subject to change without notice. All dimensions shown are approximate. Please be aware
that Teraoka has indicated that its hardware and software used in the product may require additional updates in
the future as our product is continually under development. The need for such updates most likely applies to the
Printer software.
TRK-RF-06 User Manual
3
iii) Safety Regulations
Federal Communication Commission Interference Statement
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to
Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may cause harmful interference to
radio communications. However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is encouraged to try to
correct the interference by one of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)
This device may not cause harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance
could void the user's authority to operate this equipment.
IMPORTANT NOTE:
FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This
equipment should be installed and operated with minimum distance 20cm between the radiator & your body.
This device is intended only for OEM integrators under the following conditions:
1) The antenna must be installed such that 20 cm is maintained between the antenna and users, and
2) The transmitter module may not be co-located with any other transmitter or antenna,
As long as condition above are met, further transmitter test will not be required. However, the OEM integrator is
still responsible for testing their end-product for any additional compliance requirements required with this
module installed (for example, digital device emissions, PC peripheral requirements, etc.).
IMPORTANT NOTE: In the event that these conditions do not be met (for example certain laptop
configurations or co-location with another transmitter), then the FCC authorization is no longer considered valid
and the FCC ID could not be used on the final product. In these circumstances, the OEM integrator will be
responsible for re-evaluating the end product (including the transmitter) and obtaining a separate FCC
authorization.
End Product Labeling
The final end product must be labeled in a visible area with the following: “Contains FCC ID: SUFTRKRF06”.
Manual Information To the End User
The OEM integrator has to be aware not to provide information to the end user regarding how to install or
remove this RF module in the user’s manual of the end product which integrates this module.
The end user manual shall include all required regulatory information/warning as show in this manual.
TRK-RF-06 User Manual
4
Canada Regulatory Wireless Notice:
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the
following two conditions:
1) This device may not cause interference and
2) This device must accept any interference, including interference that may cause undesired
operation of the device
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de
licence. L'exploitation est autorisée aux deux conditions suivantes :
1) le dispositif ne doit pas produire de brouillage préjudiciable, et
2) ce dispositif doit accepter tout brouillage reçu, y compris un brouillage susceptible de provoquer un
fonctionnement indésirable
IC Radiation Exposure Statement:
This equipment complies with IC radiation exposure limits set forth for an uncontrolled environment. This
equipment should be installed and operated with minimum distance 20cm between the radiator & your body.
Déclaration d'exposition aux radiations:
Cet équipement est conforme aux limites d'exposition aux rayonnements IC établies pour un environnement
non contrôlé. Cet équipement doit être installé et utilisé avec un minimum de 20 cm de distance entre la source
de rayonnement et votre corps.
This device is intended only for OEM integrators under the following conditions:
1) The antenna must be installed such that 20 cm is maintained between the antenna and users, and
2) The transmitter module may not be co-located with any other transmitter or antenna.
As long as condition above are met, further transmitter test will not be required. However, the OEM integrator is
still responsible for testing their end-product for any additional compliance requirements required with this
module installed (for example, digital device emissions, PC peripheral requirements, etc.).
Cet appareil est conçu uniquement pour les intégrateurs OEM dans les conditions suivantes:
(Pour utilisation de dispositif module)
1) L'antenne doit être installée de telle sorte qu'une distance de 20 cm est respectée entre l'antenne et les
utilisateurs,et
2) Le module émetteur peut ne pas être coïmplanté avec un autre émetteur ou antenne.
Tant que les condition ci-dessus sont remplies, des essais supplémentaires sur l'émetteur ne seront pas
nécessaires. Toutefois, l'intégrateur OEM est toujours responsable des essais sur son produit final pour toutes
exigences de conformité supplémentaires requis pour ce module installé
IMPORTANT NOTE: In the event that these conditions can not be met (for example certain laptop
configurations or co-location with another transmitter), then the IC authorization is no longer considered valid
and the IC ID can not be used on the final product. In these circumstances, the OEM integrator will be
responsible for re-evaluating the end product (including the transmitter) and obtaining a separate IC
authorization.
NOTE IMPORTANTE:
Dans le cas où ces conditions ne peuvent être satisfaites (par exemple pour certaines configurations
d'ordinateur portable ou de certaines co-localisation avec un autre émetteur), l'autorisation du Canada n'est
plus considéré comme valide et l'ID IC ne peut pas être utilisé sur le produit final. Dans ces circonstances,
l'intégrateur OEM sera chargé de réévaluer le produit final (y compris l'émetteur) et l'obtention d'une
autorisation distincte au Canada.
TRK-RF-06 User Manual
5
End Product Labeling
The final end product must be labeled in a visible area with the following: “Contains IC:5663A-TRKRF06”.
Plaque signalétique du produit final
Le produit final doit être étiqueté dans un endroit visible avec l'inscription suivante: "Contient des IC: 5663A-
TRKRF06".
Manual Information To the End User
The OEM integrator has to be aware not to provide information to the end user regarding how to install or
remove this RF module in the user’s manual of the end product which integrates this module.
The end user manual shall include all required regulatory information/warning as show in this manual.
Manuel d'information à l'utilisateur final
L'intégrateur OEM doit être conscient de ne pas fournir des informations à l'utilisateur final quant à la façon
d'installer ou de supprimer ce module RF dans le manuel de l'utilisateur du produit final qui intègre ce module.
Le manuel de l'utilisateur final doit inclure toutes les informations réglementaires requises et avertissements
comme indiqué dans ce manuel.
TRK-RF-06 User Manual
6
For Taiwan 警語:
第十二條
經型式認證合格之低功率射頻電機,非經許可,公司、商號或使用者均不得擅自變更頻率、加大功率或變更
原設計之特性及功能。
第十四條
低功率射頻電機之使用不得影響飛航安全及干擾合法通信;經發現有干擾現象時,應立即停用,並改善至無
干擾時方得繼續使用。前項合法通信,指依電信法規定作業之無線電通信。低功率射頻電機須忍受合法通信
或工業、科學及醫療用電波輻射性電機設備之干擾。
IMPORTANT NOTE:
1. 本模組於取得認證後將依規定於模組本體標示審驗合格標籤
2. 系統廠商應於平台上標示「本產品內含射頻模組: CCXXXXYYyyyZzW」字樣
TRK-RF-06 User Manual
7
1. General
The module design is based on RF transceiver with integrated MCU core, CC2541. It implements a proprietary
communications protocol streamlined to lower cost and power consumption. The antenna used is a PCB
antenna. The module will be FCC and TELEC certified for fast and simple integration into end applications. This
module may be integrated into a wireless application that operates in 2.4G ISM frequency band.
1.1 Product Features
Model
:
TRK-RF-06 (RF_CC2541 Module EXT)
Dimension (in mm)
:
20.0(L) X 19.0(W) X 4.0(H)
RF Standard
:
FCC, NCC, IC
TELEC
Modulation
:
GFSK
Frequency Band
:
2.402 GHz – 2.480 GHz
Channel list
:
79 Channels at 1MHz step
2402MHz +(n-1)MHz where n = 1 to 79
Radio Range
:
Up to 100m, L.O.S
Transmit Power (EIRP)
:
11.83dBm (max)
Receiver Sensitivity
:
-90dBm (typical), PER = 1%
General purpose I/O
:
36
1.2 Operating Specification
Voltage
:
DC 3.0V
Current
:
100mA TX mode,
Operating Temperature
:
-20 °C to 40 °C
Storage Temperature
:
-40 to +85° C
Humidity
:
95% max non condensing
TRK-RF-06 User Manual
8
2 Dimension
3. Label Information
TRK-RF-06 User Manual
9
4. Interface
Interface pin assignments
1
VDD
25
P0_3
2
VDD
26
P0_2
3
GND
27
P0_1
4
GND
28
P0_0
5
GND
29
RESET_N
6
GND
30
GND
7
DC
31
GND
8
DD
32
P1_4
9
P2_0
33
P1_5
10
P1_7
34
P1_6
11
GND
35
P2_3
12
GND
36
P2_4
13
SCL
14
SDA
15
GND
16
P1_3
17
P1_2
18
P1_1
19
P1_0
20
GND
21
GND
22
P0_6
23
P0_5
24
P0_4
Notes:
1. The I/O pins is connected to the external interface port directly.
2. The voltage level is TTL high/low voltage level.
TRK-RF-06 User Manual
10
5. Revision Records
Serial
No.
Date
Edition
Status
Description of Changes
Software
Version
Remarks
1
02/09/2013
1.0
INITIAL RELEASE
2
16/10/2013
1.1
UPDATE FCC ID AND IC ID
3
31/10/2013
1.1
UPDATE THE CANADA
STATEMENT DUE TO >10mW