DIGIRAY CRSCANNER1 Computed Radiography Scanner (Model: FireCR) User Manual
3D IMAGING & SIMULATIONS CORP. Computed Radiography Scanner (Model: FireCR)
DIGIRAY >
Contents
- 1. User manual
- 2. User Manual
User Manual
User Manual Computed Radiography Scanner Doc No. : TM -701 Rev 0.1.4 18.Oct.2011 Part No. : CR-FPM-01-001 3DISC, FireCR, Quantor and the 3D Cube are trademarks of 3D Imaging & Simulations Corp, South Korea, and its affiliates. All other trademarks are held by their respective owners and are used in an editorial fashion with no intention of infringement. The data in this publication are for illustration purposes only and do not necessarily represent standards or specifications, which must be met by 3D Imaging & Simulations Corp. All information contained herein is intended for guidance purposes only, and characteristics of the products and services described in this publication can be changed at any time without notice. Products and services may not be available in your local area. Please contact your local sales representative for availability information. 3D Imaging & Simulations Corp. strives to provide as accurate information as possible, but shall not be responsible for any typographical error. © Copyright 2010 3D Imaging & Simulations Corp, all rights reserved, printed, and published in South Korea by 3D Imaging & Simulations Corp. User Manual FireCR TM-701 Contact 815, Tamnip-Dong, Yuseong-Gu, Daejeon, Korea Tel : 82-42-931-2100 Fax : 82-42-931-2299 Website : www.3DISCimagning.com E-mail : info@3DISCimaging.com 3DISC Americas 45921 Maries Road, #190 Dulles, VA 20166 USA Tel : 1-703-430-6080 E-mail : sas@3DISCimaging.com 3DISC Europe Gydevang, 39-41, 3450 Alleroed, Denmark Tel : 45-88-276-650 E-mail : twe@3DISCimagning.com User Manual FireCR TM-701 INFORMATION TO USER: The device complies with Part 15 of the FCC Rules. Operation is subject to the condition that this device does not cause harmful interference. NOTE : This equipment has been tested and found to comply with the limits for a Class B Digital Device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction, may cause harmful interference to radio communication. However, there is no guarantee that interference will not occur in a particular installation. If this equipment dose cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures 1. Reorient or relocate the receiving antenna. 2. Increase the separation between the equipment and receiver 3.Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. 4. Consult the dealer or an experienced radio/TV technician for help. User Manual FireCR TM-701 Warnings and Used Symbols To ensure the safety of patients, staff and other persons, any changes to software and hardware delivered by 3D Imaging & Simulations Corp. may only be made with prior written permission from 3D Imaging & Simulations Corp. Please read the respective manuals of the connected software, such as acquisition and diagnostic software, before starting to use the FireCR system. The following symbols will be used throughout this manual: DANGER The functionality of the system can be destroyed in the case of incorrect use. If unauthorized changes have been made to delivered system and accessories, the warranty by 3D Imaging & Simulations Corp. becomes void. 3D Imaging & Simulations Corp. will not accept any responsibility or liability for the proper functioning of the product in such a case. WARNING The functionality of the system can be limited in the case of incorrect use. Hints that require special attention. NOTE Notes represent information that is important to know but which do not affect the functionality of the system. User Manual FireCR TM-701 General Safety Guidelines All the safety and operating instructions should be read carefully before this device is operated. This device has been designed and tested to meet strict safety requirements applicable to medical equipment, and has been supplied in a safe condition. To ensure personnel and patient safety, the device shall be operated and serviced in compliance with all procedures, warnings and precautions during all phases of operation and service of this device. Failure to comply to with safety guidelines may result in injury to service personnel, operator, or patient. 3D Imaging & Simulations Corp. assumes no liability for failure to comply. If this device is not used as specified, the protection provided by the device could be impaired. This device must be used in a normal condition only. Installation, service and operation of this device should only be undertaken by qualified trained personnel. The operator should study instructions and precautions carefully before starting to use the device listed here and throughout the manual. There are no user serviceable parts inside this device. The device should only be opened and serviced by qualified service personnel. Failure to heed this warning may result in injury to service personnel or damage to equipment, and void any and all warranties. If there is a service problem, please contact 3D Imaging & Simulations Corp. or authorized dealer. Do not spill liquids on the device, and never operate the device in a wet environment. Keep the device from radiators and heat sources. Use the device only with accessories supplied with this device. This device is intended to be grounded. Plug power cord into properly grounded electrical outlets. This cord is equipped with three-prong plugs to help ensure proper grounding. This device contains static sensitive components. equipment must be used when servicing this device. Do not look inside of the device. Proper static handling procedures and User Manual FireCR TM-701 If any of the following conditions occur, unplug the device from the electrical outlet and contact authorized service personnel. The power cord or power adapter is damaged. An object has fallen into the device. The device has been exposed to water. The device has been dropped or damaged. The device does not operate correctly when the operating instructions are followed. Intended Use This device is a Computed Radiography System and intended for use in producing digital X-Ray images for general radiography purposes. It comprises of scanner, cassette with reusable imaging plate and workstation software. It scans X-Ray exposed image plate and produces XRay image in digital form. Then, digital image is transferred to workstation for further processing and routing. This device is intended to be operated in a radiological environment by qualified staff. FireCR is not approved for the acquisition of mammographic image data. CAUTION Changes or modifications not expressly approved by the manufacturer responsible for compliance could void the user’s authority to operate the equipment. User Manual FireCR TM-701 Index of contents Chapter 1. Introduction ..................................................................... 9 Chapter 2. Unpacking ......................................................................11 2.1. 2.2. 2.3. Inspection for Damage ....................................................................11 Unpack the Shipping Container .......................................................11 Identify the Components ................................................................. 13 Chapter 3. Setting Up ..................................................................... 16 3.1. 3.2. 3.3. Tabletop Mount ............................................................................... 16 Wall Mount (Option) ........................................................................ 18 Identify Important Features ............................................................. 20 3.1. 20 3.3.1. Scanner Connecting Part ......................................................... 20 3.3.2. Scanner Status Indication LED ................................................. 20 3.3.3. Scanner Reset Button .............................................................. 21 3.4. Computer Requirements ................................................................ 22 3.4.1. Recommended Requirement .................................................... 22 3.4.2. Minimum Requirement ............................................................. 22 3.5. Installation of Acquisition and Diagnostic Software......................... 22 3.6. Connect the Cable and Power Cord ............................................... 23 3.6.1. Connect Interface Cable ........................................................... 23 3.6.2. Connect the Power Cord .......................................................... 24 3.6.3. Installation Report ..................................................................... 25 Chapter 4. Operating ...................................................................... 26 4.1. System Specifications .................................................................... 26 4.2. 4.3. Operation Conditions ...................................................................... 27 Operating Instructions .................................................................... 28 4.3.1. Turn on the Scanner ................................................................. 28 4.3.2. Turn on the Computer ............................................................... 28 4.3.3. Cassette Insert and Eject ......................................................... 28 4.3.4. Getting a Scanned Image ......................................................... 28 4.3.5. Circuit Functions ....................................................................... 29 Chapter 5. Symbols ........................................................................ 30 5.1. 5.2. Manufacturer’s Declaration - Electromagnetic Emission .............. 31 Manufacturer’s Declaration - Electromagnetic Immunity ................ 31 User Manual FireCR TM-701 5.3. Guidance and Manufacturer ’s Declaration – Electromagnetic Immunity ..................................................................................................... 34 Chapter 6. Warranty and Repair Service ........................................ 35 6.1. 6.2. 6.3. 6.4. Standard Warranty.......................................................................... 35 Repair Service ................................................................................ 35 Out of Warranty Repair Service ...................................................... 35 Shipping ......................................................................................... 36 Chapter 7. Technical Assistance ..................................................... 37 User Manual FireCR TM-701 Chapter 1. Introduction Thank you very much for deciding on FireCR – Computed Radiography Scanner. The FireCR System is ideal for a wide range of Computed Radiography examinations in specialty practices such as chiropractors, podiatrists and orthopedists. The FireCR can be configured for nearly every clinical application, and is designed for full DICOM connectivity, and allows user to setup the system to capture high quality X-ray images of any body parts with minimal steps including reading, processing, displaying and sending of the high quality image. All imaging parameters are optimized, resulting in digital images that can be enhanced, enlarged, duplicated, and sent to any location as a DICOM 3.0 file format in seconds with no loss of resolution. Combine the system with reusable phosphor screen equipped FireCR cassettes and portable X-ray equipment, it can be used for X-ray exams everywhere it is needed, e.g. nursing facilities, forensic institutions, employee screenings etc. The FireCR System is ideal for Computed Radiography examinations in busy clinics and specialty practices. Affordable, rugged, compact, lightweight, fast and effective FireCR System enables all imaging functions to be performed with the advanced image management software, a solution that can be adapted most clinical applications. The FireCR Computed Radiography solution with enhanced workflow and improved productivity are the best solution for medium sized healthcare facilities and clinics. The FireCR System complements centralized CR and DR environments such as clinics, ER and OR departments. User Manual FireCR TM-701 Main Features State-of-the-Art Scanning Mechanism FireCR adopts state-of-the-art scanning mechanisms using high beam delivery efficiency optics module to construct its compact and rigid structure. High Throughput Its unique and patented dual direction scanning mechanism enables to improve the efficiency and high throughput. Scanning Resolution User selectable resolution of 100m and 200m allows user to make diagnosis on variable purposes. Detector High sensitive photomultiplier tube equipped in FireCR delivers high gain, wide dynamic range and high speed response for radiographic imaging. Powerful Acquisition and Diagnostic Software Acquisition and Diagnostic Software designed for the FireCR, and its accurate and rapid data processing make the scanner more powerful. 10 User Manual FireCR TM-701 Chapter 2. Unpacking 2.1. Inspection for Damage FireCR is shipped in a custom designed container to protect the scanner from external shock. Before unpacking the scanner, inspect the shipping container for damage. In case the container is damaged, notify the shipper immediately. 2.2. Unpack the Shipping Container Open the shipping container by rotating the butterfly shape lock and remove items from the container. Butterfly shape lock Figure 1. Shipping Container 11 User Manual FireCR TM-701 Open the shipping container, and remove the scanner and accessories as described below. Pouch for cassette, manual and software CD Space for power adapter, power cord and USB cable Strap for scanner removal Figure 2. Inside of Shipping Container Pull two straps to remove the scanner. And remove the cassette, manuals and Acquisition and Diagnostics Software CD from the pouch attached to the lid. WARNING If the FireCR needs to be returned to manufacturer or one of its representatives, the scanner must be repacked in the original container with all accessories. DANGER Weight of the scanner is approximately 30 kg (65 lbs), and it requires two persons to lift. 12 User Manual FireCR TM-701 2.3. Identify the Components Identify each of these components. Part No. Item CR-FP-01-00X FireCR CR Scanner CR-FP-02-003 Universal Cassette 14” x 17” containing IP size 14” x 17” CR-FP-02-004 Universal Cassette 14” x 10” containing IP size 10” x 12” CR-FPA-01-001 Power Adapter CR-FPA-02-001 USB 2.0 Interface Cable CR-FPA-03-00X Power Cord CR-PKM-01-001 Transportation Flight Case with Rollers CR-FPM-01-001 FireCR User Manual FireCR Computed Radiography Scanner 13 User Manual FireCR TM-701 10” x 12” Cassette (Imaging Plate Included) 14” x 17” Cassette (Imaging Plate Included) USB 2.0 Interface cable FireCR User manual Power cord Power adapter Transportation case Figure 3. Components 14 User Manual FireCR TM-701 WARNING Use of Power Cord; Type SJT or SVT, min. 18AWG, 3-Conductor, VW-1 125V, min 10A (or 250V, 10A). Max 3.0m long; One end with Hospital Grade Type, NEMA 5-15P for 125V or NEMA 6-15P for 250V. Other end with appliance coupler. “CAUTION Grounding reliability can only be achieved when the equipment is connected to an equipment receptacle marked “Hospital Only” or “Hospital Grade”. For connection to supply not in USA, make sure the power cord is the correct type that is required in your area. WARNING Improper disposal of this product may result in environmental contamination. When disposing of this equipment, contact 3D Imaging & Simulations Corp.’s representative or related organs of government. Do not dispose of any part of this equipment without consulting a 3D Imaging & Simulations Corp.’s representative first. 3D Imaging & Simulations Corp. does not assume any responsibility for damage resulting from disposal of this equipment without consulting 3D imaging & Simulations Corp. NOTE AC/DC Adapter Manufacturer : Bridge Power corp. Model : BPM150X24XFX (Xs are alphanumeric suffix not related to safety) This adapter is passed by IEC60601-1. WARNING Use the device passed IEC60950-1 or IEC60601-1 for the product connected via USB port. 15 User Manual FireCR TM-701 Chapter 3. Setting Up WARNING Unsuitable Installation Sites Locations with excessive humidity or dust Locations subject to high temperature Locations subject to shaking or vibration Locations exposed to considerable electrical or magnetic noise, or other forms of electromagnetic energy Locations with poor heat radiation 3.1. Tabletop Mount The scanner must be placed on a rigid and flat desk or tabletop with at least 10 cm (4 inch) free space on both sides, 20 cm (8 inch) on rear side and 50 cm (20 inch) on front side for cassette insertion. Its space requirements are shown below. Free space of 20 cm (8 Free space of 50 cm (20 inch) inch) on front side, at on backside, at least, to allow the power least, for cassette insertion switch, power cord and and ejection. USB cord to be reached by hand at all times. Front Side Backside Figure 4. Tabletop Mount Space Requirements (Top View) 16 User Manual FireCR TM-701 In case that desk or table is not flat, adjust feet under the scanner for leveling. The scanner weighs approximately 30 kg (65 lbs) and requires two persons to lift. Carefully place the scanner into its final position. Adjustable foot Figure 5. Scanner Leveling DANGER Never place the scanner on the floor. Sliding the scanner may result in internal damage or misalignment of the optics. Install in a location that is level and stable. Installation in an unsuitable location can cause accident, or deterioration in image quality. WARNING Sliding the scanner may result in internal damage or misalignment of the optics. External vibration or shock during scanning may affect image quality. The scanner must be placed on rigid, flat and reinforced desk or tabletop. 17 User Manual FireCR TM-701 WARNING Do not place anything on top of the scanner. WARNING This equipment may be interfered or interfere by electromagnetic or other interference. Assure a distance of minimum 1.0 m with neighboring equipment. 3.2. Wall Mount (Option) The FireCR can be mounted on the wall to save space occupancy. When purchasing the wall mount kit, a detailed installation guide and all parts necessary for assembly are provided. DANGER Only authorized or trained personnel should set wall mount installation. NOTE Refer to Wall Mount Installation Guide provided with Wall Mount Installation Kit. DANGER Install the wall mount on a solid wall perpendicular to the floor. When attaching to other building materials, please contact your local dealer. If installed on a slanted wall, it may fall and result in severe injury. 18 User Manual FireCR TM-701 DANGER 3D Imaging & Simulations Corp. is not liable for product damage or personal injury when the user fails to follow the product installation instruction. WARNING Pulling, pushing, or climbing on the system may cause the system fall. Free space of 50 cm (20 inch) on top side, at least, for cassette insertion and ejection. Front Side Free space of 10 cm (4 inch) on sides, at least. Back Side Free space of 20 cm (8 inch) on back side, at least, to allow the power switch, power cord and USB cord to be reached by hand at all times. Figure 6. Wall Mount Space Requirements (Front View) 19 both User Manual FireCR TM-701 3.3. Identify Important Features Look over the scanner and features shown in this section. User will need to know where these features are when user operates the scanner in later chapters. 3.3.1. Scanner Connecting Part Power Switch USB 2.0 Port Power Inlet Figure 7. Scanner Important Features 3.3.2. Scanner Status Indication LED Indication LED shows the status of the scanner as described below. LED Green Blue On On Remark System On Cassette is in initial position, and ready to scan. Ready to Scan Blinking Blinking Status Blinking Blinking Scanning Erasing Error 20 User Manual FireCR TM-701 Status Indication LED Figure 8. Scanner Status Indication LED 3.3.3. Scanner Reset Button In case that the scanner is stuck during scanning, push scanner reset button by sharp pin to initialize the scanner. Scanner Reset Button Figure 9. Scanner Reset Button 21 User Manual FireCR TM-701 WARNING Do not push scanner reset button during scanning. 3.4. Computer Requirements 3.4.1. Recommended Requirement Operation System CPU Memory Microsoft Windows XP (32bit) or 7 (32bit) Core Duo / Core2 Processor RAM 4GB or more Hard Disk 300GB Free Hard Disk Space Network Video Video Resolution 1Gbps Ethernet 32 bit Color Display 1280 x 1024 3.4.2. Minimum Requirement Operation System CPU Memory Microsoft Windows XP (32bit) or 7 (32bit) Core Duo / Core2 Processor RAM 2GB or more Hard Disk 80GB Free Hard Disk Space Network Video Video Resolution 1Gbps Ethernet 32 bit Color Display 1280 x 1024 3.5. Installation of Acquisition and Diagnostic Software Refer to Acquisition and Diagnostic Software manual. 22 User Manual FireCR TM-701 3.6. Connect the Cable and Power Cord 3.6.1. Connect Interface Cable The scanner interfaces with computer via USB2.0 cable. 1. Use the USB cable in the shipping container. 2. Connect the cable to the scanner’s USB2.0 port, located on the rear of the scanner. 3. Connect the other end of the cable to the USB2.0 port on the computer. Figure 10. USB Connection DANGER This equipment is indoor use only and all the communication wirings are limited to inside of the building. WARNING Do not pull out the USB cable during scanning. 23 User Manual FireCR 3.6.2. TM-701 Connect the Power Cord 1. Connect the power cord to the scanner, located on the rear side. 2. Connect the other end of the cord to a grounded power outlet. Figure 11. Power Connection DANGER This equipment must only be connected to supply mains with protective earth. Use only a three-wire cord that has grounding. This is a safety feature. If you are unable to insert the plug into the outlet, contact your electrician to replace your obsolete outlet. Do not defeat the safety purpose of the grounding-type plug. DANGER Do not use with any electrical power supply that does not meet the ratings displayed on the power adapter. Use with any other power adapter may lead to fire or electrocution. DANGER Do not use any power adapter and power cord other than the power adapter and power cord included with the system. Doing so may lead to fire, electrical shock, or electrocution. 24 User Manual FireCR TM-701 WARNING Socket-outlet shall be installed near the device and shall be easily accessible. Do not place the device where difficult to access to appliance inlet. Do not unplug the power cord or turn the power switch off during scanning. 3.6.3. Installation Report After installation of the scanner, fill in Installation Report from (Appendix I) and send to 3D Imaging & Simulations Corp. service department by fax or e-mail. Fax : +82-42-931-2299 E-mail : support@3-disc.com 25 User Manual FireCR TM-701 Chapter 4. Operating 4.1. System Specifications Sampling Pixel Pitch Pixel Matrix (IP 14” x 17”) Pixel Matrix (IP 10” x 12”) Standard 200um High 100um Standard 1750 x 2150 High 3500 x 4300 Standard 1250 x 1500 High 2500 x 3000 Accepted Cassette Size 14” x 17”, 14” x 10” Gray Scale Resolution 16 bit Eraser Embedded Computer Interface USB 2.0 Dimensions 117 (H) x 464 (W) x 703 (D) mm 4.8 (H) x 18.3 (W) x 27.7 (D) inch Weight 30 kg (65 lbs) Power Requirement 100 ~ 240V / 50 ~ 60Hz System Configuration Tabletop or Wall Mount Image File Format DICOM 3.0 * Specifications subject to change without notice. ** Specific results may vary since operating conditions fluctuate. 26 User Manual FireCR TM-701 4.2. Operation Conditions Indoor use only Operating Temperature 15C ~ 30C (59F ~ 86F) Temperature Gradient 0.5C / Min Relative Humidity Storage Temperature 15% ~ 95% (non-condensing) - 10C ~ 50C (14F ~ 122F) 15% ~ 95% (non-condensing) 500 ~ 1,060 hPa Storage Humidity Storage Atmospheric Pressure Transportation Temperature Transportation Humidity Transportation Atmospheric Pressure Installation Category Pollution Degree Ingress of Liquids Altitude Protective Class Equipment Maintenance Cleaning - 10C ~ 50C (14F ~ 122F) 15% ~ 95% (non-condensing) 500 ~ 1,060 hPa II IPX0 Up to 2,000m Class 1 No user maintenance is required and no user service is allowed. Please contact technical support if there is a problem. Do not try to clean inside of the scanner. Wipe outside of the scanner for dust removing with soft and dry cloth. DANGER There are no user serviceable parts inside the scanner. The scanner should only be opened and serviced by qualified service personnel. Failure to heed this warning may result in injury to service personnel or damage to equipment, and void any and all warranties. If there is a service problem, please contact 3D Imaging & Simulations Corp. or authorized dealer. 27 User Manual FireCR TM-701 4.3. Operating Instructions 4.3.1. Turn on the Scanner Turn on the scanner. Power switch is on the rear side of the scanner. DANGER This device uses laser. Avoid looking inside of the scanner. 4.3.2. Turn on the Computer Turn on the computer. Acquisition and Diagnostic Software must be installed before operate the scanner. 4.3.3. Cassette Insert and Eject Insert the cassette to the entrance of the scanner and push gently until it reaches to the protection wall inside of the scanner. Green indication LED is on when the cassette is inserted correctly. Insertion direction of the cassette must be parallel to the scanner. Cassette can be ejected when scanning and erasing are completed. Gently pull back the cassette and ejection direction of the cassette must be parallel to the scanner. WARNING Do not insert the cassette in wrong direction or upside down when it is being inserted. Cassette insertion direction is marked on the cassette. 4.3.4. Getting a Scanned Image To getting a scanned image, refer to Acquisition and Diagnostic Software manual. 28 User Manual FireCR 4.3.5. TM-701 Circuit Functions Figure 11. Circuit diagram Base Board: Base board is a controller of peripherals. It controls peripherals upon command of core board. Peripheral: This is peripherals for image acquisition. It consists of “Eraser” which erases residual images in imaging plate, “Step Motor and Photo Interrupters” which moves stage, “Laser, Mirror and DC Motor” which are required to radiate laser onto imaging plate, “Edge Switch and DC Motor” which assures proper insertion of the cassette, and “Indicator” which displays the status of the system. Base Board Image Data Controller (Core Board): This parts controls peripherals for image acquisition. And it delivers amplified digitized signal to PC via USB. Image Sensor (PMT): This Photomultiplier Tube receives the signal through scanning of imaging plate, and it sends signal to analog readout circuit. Power Adapter: It supplies power to all modules of the system which are required for operation. 29 User Manual FireCR TM-701 Chapter 5. Symbols Symbol Description Warning, Consult Accompany Documents. Manufacturer ON Equipment Power On OFF Equipment Power Off Date of Manufacture FCC ID : X68CRSCANNER1 FCC Mark Medical Equipment WITH RESPECT TO ELECTRIC SHOCK FIRE, AND MECHANICAL HAZARDS ONLY IN ACCORDANCE WITH UL60601-1 / CAN / CSA CSS.2 No. 601.1 3SE3 CE Mark 30 User Manual FireCR TM-701 5.1. Manufacturer’s Declaration - Electromagnetic Emission The FireCR system is intended for use in the electromagnetic environment specified below. The customer or the user of FireCR system should assure that it is used in such an environment Emission test Compliance RF emissions Group 1 CISPR 11 Electromagnetic environment - guidance The FireCR system uses RF energy only for its internal function. Therefore. Its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment RF emissions Class B CISPR 11 establishments, including domestic Harmonics emission establishments and those directly connected to the public low-voltage power supply network that IEC 61000-3-2 Voltage fluctuation The Model FireCR is suitable for use in all Complies supplies buildings used for domestic purposes. IEC 61000-3-3 5.2. Manufacturer’s Declaration - Electromagnetic Immunity The FireCR system is intended for use in the electromagnetic environment specified below. The customer or the user of FireCR system should assure that it is used in such an environment Immunity test IEC 60601 Test level Compliance level Electrostatic discharge (ESD) IEC 61000-4-2 6 kV Contact 8 kV Air 6 kV Contact 8 kV Air Electrical fast Transient / burst IEC 61000-4-4 2kV for power supply lines 1kV for input/output lines 2kV for power supply lines 1kV for input/output lines Surge IEC 61000-4-5 1 kV differential mode 2 kV common mode 1 kV differential mode 2 kV common mode 31 Electromagnetic Environment -guidance Floors should be wood, concrete or ceramic tile. If floors are covered with synthetic material, the relative humidity should be at least 30% Mains power quality should be that of a typical commercial or hospital environment. Mains power quality should be that of a typical commercial or hospital environment. User Manual FireCR Power frequency (50/60Hz) Magnetic field IEC 61000-4-8 TM-701 3.0 A/m 3.0 A/m Power frequency magnetic fields should be at levels characteristic of a typical location in a typical commercial or hospital environment. Voltage dips, short <5% Uт (>95% dip in Uт) <5% Uт (>95% dip in Uт) Mains power quality should be Interruptions and for 0.5cycle for 0.5cycle that of a typical commercial or hospital environment. If the Voltage variations on power supply 40% Uт (60% dip in Uт ) 40% Uт (60% dip in Uт ) user of the BSVD-1000 input lines for 5 cycle for 5 cycle system requires continued IEC 61000-4-11 operation during power mains 70% Uт (30% dip in Uт) 70% Uт (30% dip in Uт) interruptions, it is for 25 cycle for 25 cycle recommended that the BSVD1000 system be powered from <5% Uт (<95% dip in Uт ) <5% Uт (<95% dip in Uт ) an uninterruptible power for 5 s for 5 s supply or a battery Conducted RF 3 Vrms 3 Vrms Portable and mobile RF IEC 61000-4-6 150 kHz to 80 MHz 150 kHz to 80 MHz communications equipment should be used no closer to any part of the FireCR system, including cables, than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter. Recommended separation distance Radiated RF IEC 61000-4-3 3 V/m 80.0 MHz to 2.5 GHz 3 V/m 80.0 MHz to 2.5 GHz Recommended separation distance Where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer and d is the recommended separation distance in meters (m). Field strengths from fixed RF transmitters, as deter-mined by an electromagnetic site survey, (a) Should be less than the compliance level in each frequency range (b). Interference may occur in the vicinity of equipment marked with the following symbol: 32 User Manual FireCR TM-701 Note 1) Uт is the A.C. mains voltage prior to application of the test level. Note 2) At 80 MHz and 800 MHz, the higher frequency range applies. Note 3) These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. a Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the EUT is used exceeds the applicable RF compliance level above, the EUT should be observed to verifynormal operation. If abnormal performance is observed, additional measures may be necessary, such as re-orienting or relocating the EUT. b Over the frequency range 150 kHz to 80 MHz, field strengths should be less than [V1] V / m. Recommended Separation Distances Between Portable and Mobile RF Communications Equipment and the FireCR system. The FireCR system is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The user of the FireCR system can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the FireCR system as recommended below, according to the maximum output power of the communications equipment. Separation distance (m) according to frequency of transmitter Rated maximum output power (W) of transmitter 150 kHz to 80 MHz 80 MHz to 800 MHz 800 MHz to 2.5 GHz 0.01 0.12 0.12 0.23 0.1 0.37 0.37 0.74 1.17 1.17 2.33 10 3.70 3.70 7.37 100 11.70 11.70 23.30 For transmitters rated at a maximum output power not listed above, the recommended separation distance (d) in meters (m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer. Note 1: At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies. Note 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects, and people. Immunity and Compliance Level Immunity test IEC 60601 Test Level Actual Immunity Level Compliance Level Conducted RF 3 Vrms, 150 kHz to 80 3 Vrms, 150 kHz to 80 3 Vrms, 150 kHz to 80 IEC 61000-4-6 MHz MHz MHz Radiated RF 3 V/m, 80 MHz to 2.5 3 V/m, 80 MHz to 2.5 GHz GHz 3 V/m, 80 MHz to 2.5 IEC 61000-4-3 GHz 33 User Manual FireCR TM-701 5.3. G u i d a n c e a n d M a n u f a c t u r e r ’ s D e c l a r a t i o n – Electromagnetic Immunity The FireCR system is intended for use in the electromagnetic environment specified below. The customer or the user of FireCR system should assure that it is used in such an environment Immunity test IEC 60601 Test level Compliance level Electromagnetic environment guidance Conducted RF IEC 61000-4-6 3 Vrms 150 kHz to 80MHz 3 Vrms 150 kHz to 80 MHz FireCR system must be used only in a shielded location with a minimum RF shielding effectiveness and, for each cable that enters the shielded location with a minimum RF shielding effectiveness and, for each cable that enters the shielded location Radiated RF IEC 61000-4-3 3 V/m 80.0 MHz to 2.5GHz 3 V/m 80.0 MHz to 2.5GHz Field strengths outside the shielded location from fixed RF transmitters, as determined by an electromagnetic site survey, should be less than 3V/m.a Interference may occur in the vicinity of equipment marked with the following symbol: Note 1) These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. Note 2) It is essential that the actual shielding effectiveness and filter attenuation of the shielded location be verified to assure that they meet the minimum specification. a- Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength outside the shielded location in which the EUT is used exceeds 3V/m, the EUT should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as relocating the EUT or using a shielded location with a higher RF shielding effectiveness and filter attenuation. 34 User Manual FireCR TM-701 Chapter 6. Warranty and Repair Service 6.1. Standard Warranty 3D Imaging & Simulations Corp. warrants its non-consumable hardware products to be free from defects in materials and workmanship. The warranty covers the cost of parts and labor to repair the product. Please keep the shipping container for future use. Products returned to the factory for repair should be properly packaged. To obtain warranty service, follow the procedure described in the Repair Service section. Failure to do so will cause long delays and additional expense to the customer. The warranty is valid when the product is used for its intended purpose and does not cover products which have been modified without written permission from 3D Imaging & Simulations Corp., or which have been damaged by abuse, accident or connection to incompatible equipment. This warranty is in lieu of all other warranties, expressed or implied. 6.2. Repair Service The company reserves the right to cease providing repair maintenance, parts and technical support for its non-consumable hardware products five years after a product is discontinued. Technical support for old versions of software products will cease 12 months after they are upgraded or discontinued. 6.3. Out of Warranty Repair Service Out of warranty repair service is available in selected geographical locations. supplier for current terms and rates. 35 Contact the User Manual FireCR TM-701 6.4. Shipping The FireCR is a solidly built system designed to survive shipping around the world. However, in order to avoid damage during shipping, the FireCR must be properly packaged. In general, the best way to package the FireCR is in the original factory container. If this is no longer available, we recommend that user carefully wraps the FireCR in at least 75 mm (3 inch) of foam or bubble pack sheeting. The wrapped device should then be placed in a sturdy cardboard carton. Mark the outside of the box with word FRAGILE and an arrow showing which way is up. We do not recommend using loose foam pellets to protect the FireCR. If the carton is dropped by the shipper, there is a good chance that the device will shift within the loose pellet packing and be damaged. If user needs to ship the FireCR to another location, or back to the factory, and user does not have a means to adequately package it, user can order additional shipping container. This may seem an expense user would like to avoid, but it is inexpensive compared to the cost of repairing an instrument that has sustained shipping damage. It is user’s responsibility to package the system properly before shipping. If the packaging is inadequate, and the system is damaged during shipping, the shipper will not honor user’s claim for compensation. 36 User Manual FireCR TM-701 Chapter 7. Technical Assistance If user has any questions about installing or using the device, contact your 3D Imaging & Simulations Corp representative or your local dealer. 3D Imaging & Simulations Corp. 815, Tamnip-Dong, Yuseong-Gu, Daejeon, Korea Tel : 82-42-931-2100 Fax : 82-42-931-2299 www.3-disc.com 37 User Manual FireCR TM-701 Appendix I Installation Report Please complete this report at the time of installation and submit the completed form signed by customer to: Fax : +82-42-931-2299 E-mail : support@3-disc.com Date of Installation : Customer Information Hospital / Institute Name Address Tel Fax E-mail Installer Information Company Name Address Tel Fax E-mail System Information Model System S/N FireCR CR Scanner Installer’s Signature: Date: Customer’s Signature: Date: 38
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Author : 14531 Create Date : 2011:11:01 11:01:42+09:00 Modify Date : 2011:11:01 11:01:42+09:00 XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Format : application/pdf Title : Microsoft Word - TM701_FireCR_User Manual(Rev 1 4)_111031 Creator : 14531 Creator Tool : PScript5.dll Version 5.2.2 Producer : Acrobat Distiller 9.3.3 (Windows) Document ID : uuid:a169ce76-dc49-418f-aeaa-7f11419ca957 Instance ID : uuid:441663ec-d29a-4b28-b2fd-e76ffdf169a0 Page Count : 38EXIF Metadata provided by EXIF.tools