DOMITECH ZBR30DL Z-wave Light Bulb User Manual ZBR30DL Manual
DOMITECH PRODUCTS, LLC Z-wave Light Bulb ZBR30DL Manual
DOMITECH >
Manual
demiteeh Wireless Light ing Device Z-wave Smart LED Light Bulb HUS @u LISTED This product speaks with other Z-Wave certified devices FEATURES INTRODUCTION domitech Smart Light Bulb is a member of the ZrWavelK family and communicate With other ZeWavelg certified devices in a control network. The Smart Bulb can be controlled by the erave remote controller or apps. [ach ZrWave device serves as a node to repeat the Signal tn the network. thus, extending the overall ZrWave mesh wireless network range. Different types and brands of l-Wave devices can be associated with domitech Smart Bulb in your system and they will work together to optimize and expand the coverage of your ZrWave network Once setup is completed, you can enjoy the convenience and leisure which Smart Bulb offers. - Butltri’n ZrWave radio , can be controlled remotely and wtrelessly - Plugand play, Simple setup - ionger life and more energy ettioent tha - instant ”0N” - OverrTherAit firmware upgrade availabl static controller, PC and software t Powered by ZrWaveS SOU Series modul ~ Manual reset capability IWARNING! ri incandescent or florescent light bulbs e with compatible gateway, ZeWayeW 0 inside RISK OI TIRE, ELECTRICAL SHOCK & BURNS NOT FOR EMERGENCY LIGHTING [)0 NOT USE WITH MEDICAL AND LIFE SUPPORT INSTRUMENT No user serviceable ports are in this module INCLUSION Step i,'t‘urn off power to the light bulb socket of your preferred location. Step 2, Screw In the Smart Bulb into the socket Step 3, riote your network Luritruller Into inLluSIUn mode by following the controller manufacturer‘s instructions (a Step 2, Turn on power to the socket after promoted by your network controller iri(lu5i0ri mode. The Smart Bulb will be included into your network within 30 SeLuridS. The Smart bulb will flash 2 times after inclusion is Successful. lf the eontroiier/gutewuy shows it failed, repeat the procedure. Note: lf lnclusion still fails after the 2nd attempt, you need to first RESU the Smart Bulb befnte repeating the above steps. Before repeating the above steps, try moving the Smart Bulb to the bulb socket in the same room as your home gateway in case the preferred outlet is out of range initially Repeat step 1-2 until the Smart Bulb is added to your network. Once the Ilglit bulb has been successfully added to your home network, you can move it to the preterred location in the borne Manually Reset r Hick the wall switch ”OEI'VON” cycle 4 times within 4 seconds With OH and turn ON will be counted 851 ”OFFVON” eycICi. The Smart Bulb will flash tWice after Reset is successful. Use this procedure only in the event that the network primary controller is lost or otherwise inoperable BASIC OPERATION The Smart Bulb can be controlled ON/OFE/BRIGHT/DIM wirelessly with a ZrWave remote tonttollet or through a gateway vta an app on d smart phone, tablet, or a re. Depending on the capability of your controller/gateway, once the Sniart Bulb has been added to your network, you may assign ll to a Group or Scene and change its status via your controller/gateway. ASSOCIATION The Smart Bulb supports Group i with up to five devices for lit’eline communication. Groupi must be assigned the Node D of the controller to which unsolicited notifications will be sent, The ZrWave controller should set this association automatically after inclusion Lifeline association only supports thc ”manual reset" event Pleasc refer to the instructions manual of your remote controller or gateway tor detail ptotedures on how those function can be set EXCLUSION By tontrotier rThe Srnurt Bulb tun be excluded from your network by your tontroller/Cateway Similar to the Inclusion process, turn of power to your light bulb and place your network controller into excltISicm mode by following the controller manufacturer‘s instructions. Once prompted by your network controller, turn my the light switch. The Smart Bulb will flash twice to confirm that it has successfully been excluded from your network Please refer to your controller/gateway instructions manual for details By manually etho Smart Bulb can be extluded manually by flicking the wall Switch "OFF-ON” cycle 4 times within 4 seconds [Turn OIF and turn ON Will be counted as | ”OFF-0N” cycle‘i. The bulb will flash twice after Reset is successful Use this procedure only in the event that the network primary controller is lost or otherwise inoperabio. OFF x4 DFFrONeltil r in 4s Dim level when the domiteclt Smart LED Light Bulb is turned 0N (Switch ONLY) Vou may select the ditn level whenever the light is turned back ON to be either full brightness l100°/a dim level) or be the same as the last dim setting when the light is on by flicking the wall switch, Parameter 1 Length: 1 Byte Valid Values: 0 or i tdetault : 0) When value : 0, the brightness level will be resume to full brightness when the Smart Bulb is turned every time. When value : l, the brightness level will maintain same dim level as the last setting when the Smart Bulb is turned on again, Parameter s: Dimming/Brightening Step Level Vou may change the dimming step level when you adtust the brightness by your controller/gateway Parameter 9 Length: 1 Byte Valid Values: le99 (default : ii When the value is low, dimming/brightening is gradual. when the value is high, dimming/brightening is rapid. Parameter 10: Dimming/Brightening Step Timing You may change the dimming speed quicker or slower by changing Parameter io. Parameter i0 Length: ‘l Byte Valid Values: 1710 [default : 3) When the value is low, the step timing is quick. when the value is high, the step timing is slew MANUAILV TURNING ON or OFF THE lIGHT SWITCH when you want to manually tum ON the Smart Bulb whenever it is turned on by a program or a remote control, flick the switch twice. The tirst flick will cut power to the light and the 2nd flick will turn ON the light. Vou may manually switch orr the light bulb while keepin the Smart Bulb online in the network an function as a Z-Wave signal repeater to maintain proper mesh network. The tunction can be activated by flicking the wall switch "OFFVON" cycle two times within two Seconds. In other words, flick the switch four times [OFFVONVOFFVONX The Smart Bulb light will be OFF while it maintains the function as a ZsWave signal repeater and remains online to be turned ON by program or by an app wirelessly IMPORTANT NOTE: To accomplish the repeater functionality, other Zewave devises should be poweredeup state during inclusion of the Smart Bulb lt can make sure all Zewave devises are in one network, Please note that it is extremely important to follow the above practice or to use ONLY your preferred Wireless remote control device to turn ON or OFF the light. Without the electrical power to the light bulb, the Smart Bulb cannot be turned ON remotely nor function as a signal repeater to maintain proper ZsWave network. To avoid family members trom accidently turning on the power hi the Smart Bulb, install the optional clear cover that its over your wall switch included with your product, Please refer to the separate installation sheet. About the Z-Wave 500 Series Module with Z-Wave Plus features: You can use a ZrWaVe certified portable or statlc Controller to communlcate with the module. Depending on the capability of your controller or gateway sortware, the following simple to advanced operations may be pertormed. Please rerer to the controller or gateway manual for details l. Addtlnclude) or DeletetExclude) the Smart Bulb to/from your network 2. Turn On or Off the Smart Bulb remotely 3. Assign the Smart Bulb to a specific Group/Scene and/or to include the bulb as part of your ALL ON or art command, 4. OveretheeAir firmware update by your gatewa or static controller 5. Lifeline function which automaticall notifies t e associated modules and the network that a manually reset cn/ice is no longer in the network, thus, the corresponding association becomes invalid NOTE: Please note that like any other lights, the Smart Bulb Will be OFF after a power failure. The smart bulb will be ”ON” with full brightness after the power is resumed if parameteri is not changed by the controller/gateway SPECIFICATIONS Model: ZBFGDJ Will MEN lnput power: TZD VAC, 60 H/.. brightness: 650 lumens (Equivalent to osewaitt incandescent light bulb) Power Consumption; 25w Color Temperature: WI 27% Bulb Lifetime: Approx, 29,000 hours ttquivalent 228 years based on 3 hrs/day) Radio frequent: : 9084 MHz / 9T6 MHz wireless ran 'e p to 130 teet line or sight between the controller and the other avallabe nodes. Normal operating temperature: 77“F (25°C) POR INDOOR USE ONLY interoperability With ZeWave® devices A ZrWave® network can integrate devices from various classes of products, and these devices can be made by different manufacturers The domitechfb product introduced in this instructions manual has a ZsWave certification which guarantees such an interoperability FCC ID: 2AC4EZBR30DL The Federal Communication Commission Radio Frcquency Interference Statement includes the following paragraph; The equipment has been tested and found to comply with the limits for a Class B Digital Device, pursuant to part is of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment uses, generates and can radiate radio frequency energy and, if not installed and used in accordance with the instruction, may cause harmful interference to radio communication. Howe/er, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures . Reorlent or relocate the receiving antenna . Increase the separation between the equipment and receiver . Connect the equipment into an outlet on a circuit different from that to which the receiver is connected . Consult the dealer or an experienced radio/TV technician for help Operation is subject to the followmg two conditions: - This device may not cause interference . This device must accept any interference, including interference that may cause undesired operation of the device. IMPORTANT NOTE: To comply with the rec RF exposure compliance requirements, no change to the antenna or the device is permitted. Any change to the antenna or the device could result in the don/ice exceeding the RF exposure requirements and void user’s authority to operate the (IeVlCe, IC: IZ3ZDA—ZBR30DL This device complies With Industry Canada license-exempt RSS standardts), Operation is subiect to the folloWing two conditions: lil This device may not cause intenerence, and (2) This device must accept any interference, including interference that may cause undesired operation of the device. ZeWave is a registered trademark of Sigma Designs WARRANTY Domiteth Products warrano to the original purchaser of this product that for the warranty period, this product will be free from material defects in materials and workmanship. The foregoing warranty is subject to the proper installation, operation and maintenance of the product in accordance with installation instructions and the operating manual supplied to customer Warranty claims must be made by customer in writing within 30 days of the manifestation of a problem, Domitech’s sole obligation under the foregoing warranty is to repair, replace or correct any such defect that was present at the time of delivery, or to remove the product and to refund the purchase price to customer. The warranty does not extend to consequential or incidental damage to other products that may be used With this product. For inquiry and customer service, email to supporttmdomitcchproductscom Warranty period: limited l year from date of purchase Domitech Products, LLC IMO E. Southlakc Blvd. Suite L73i2 Southlake, Texas 76092
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes XMP Toolkit : 3.1-701 Producer : Acrobat Distiller 7.0 (Windows) Creator Tool : PScript5.dll Version 5.2.2 Modify Date : 2015:07:21 10:02:27+08:00 Create Date : 2015:07:21 10:02:27+08:00 Format : application/pdf Title : ZBR30DL Manual.pdf Creator : Jacky Koo Document ID : uuid:75f49119-58b3-4dd2-949f-6ba6ef13d514 Instance ID : uuid:f697be76-1161-46b0-8493-893184e7710c Page Count : 2 Author : Jacky KooEXIF Metadata provided by EXIF.tools