Danfoss A S TYPE-CFR15 Wireless Floor Heating Control System User Manual cfm cfr install oper
Danfoss A/S Wireless Floor Heating Control System cfm cfr install oper
User manual
Installation and operation Wireless floorheating controller and room thermostat, type CF Temperature setting Set room temperature on the thermostat dial. On the right-hand side of the thermostat is a function switch with 3 possible settings: Sun: The room temperature will be as set on the thermostat. Clock: Used only if the zone regulator is engaged. The temperature will be as set on the room thermostat, but in accordance with the consumption pattern entered. The consumption pattern in the zone regulator can be overridden by moving the switch to sun or moon. Moon: The room temperature will be as set on the thermostat - minus 5°C. Limitation of the setting range Behind the button for temperature setting are two lock-pins. These can be placed in the setting knob as shown in fig. 4 if the thermostat setting range is to be narrowed. Putting into operation Each room thermostat has a unique ID number preventing conflicts with other thermostats. A single room thermostat is capable of regulating several heating outputs, provided these outputs are assigned to the thermostat. Assigning thermostats to output(s) -The installation cable between room thermostat and CFM (fig. 2) must be connected in assigning each thermostat to the respective output(s). -In the LED array the first available output will flash. The LED in the CFR will also flash. Outputs already assigned will not be lit (fig. 2). By pressing OK the thermostat will be assigned to that output. If the room thermostat is to be assigned under another lit output, scroll to the output by means of the +/- keys, then press OK. -When the installation cable is removed, the red LED behind the front panel (fig. 4) will flash for at least 4 minutes. See “Test of room thermostat” Removal of assigned thermostat -It is not necessary to have the installation cable in place when removing an assigned thermostat. Once a thermostat has been removed, it may be reassigned to another output. -Removal of room thermostat is done by pressing OK for 5 seconds, then the entire LED array will be lit. Scroll to the specific room thermostat to be removed with the +/- button,and press OK for 5 seconds. The thermostat has now been removed. Test of room thermostat If a defect in a room thermostat is suspected, the following test may be carried out: Troubleshooting - Set the thermostat to the highest temperature. - Move the function switch on the side of the room thermostat to a new position. - If the LED behind the front panel (fig. 4) flashes quickly for 4 minutes, the room thermostat is OK. Battery change If the battery is getting low, the LED will flash 6 times every 6 seconds. See fig. 4. Appearance Problem CFM controller output array blinks specifically from a row and column(s) Lack or excessive heat to floor heating system The connection cable is 5 m. Cable lengths up to 100 m are permitted (available from your electrical items supplier). Solution Comments Distance between room and master is too far. Reposition thermostat in room until signal is clear. Degradation of signal due to reinforced concrete or foil faced insulation between floors. Reposition external antenna, however if signal is still unclear move external antenna to the same floor as thermostat(s) If signal is continuosly poor contact Danfoss External antenna mounted close to metal parts or wires. Master regulator CFM This regulator governs the individual heat circuits via wireless communication with the associated room thermostats. Connection of 8 heat circuits is enabled. If more heat circuits are required, connect one or max. two slave regulators CFS, each with connection for 8 circuits. This allows max. 24 heat circuits to be governed. The master/slave is to be fitted immediately above the distributor pipe on the wall or in a distribution cabinet. Easy access to plugs and terminals should be ensured. See instruction drawing on the opposite page. If two slave regulators are connected, move the jumper in “slave 2” to position 2. See instruction drawing. The connection cable for the slave regulator is 1 m. Cable lengths of up to 100 m are enabled (available from your electrical items wholesaler) Alarm There are 2 options with respect to alarms given by the master regulator: -Integral acoustic signal can be selected by moving the jumper marked “buzzer” from OFF to ON. See installation drawing. -External alarm generator can be connected to the output marked . Technical data Max. ambient temperature 60°C. Enclosure IP40 Zone regulator CFZ The zone regulator governs a maximum of 6 heat zones. For each heat zone, individual timing programmes can be connected. For reading and operating convenience, it is recommended to place the regulator at eye height. Reason/cause Master control is placed in metal enclosure. Alarm symbol in zone controller, CFZ flashes Acoustic alarm buzzes (provided jumper is set to “ON”) Interference from electronic equipment using the same frequency, 433.92Mhz (i.e. baby monitors, portable or wireless headphones) Room temperature is below 6oC (43oF) Low battery Problem in heating system or signal to thermostat Reposition room thermostat and run test mode Mount external antenna if not already installed. Eliminate interfering electronic equipment Replace battery and test thermostat Check heating supply to the system and the circulator pump Max. load for CFM 6W, max. Load for CFS 3W Check master control, CFM, is properly wired. Master or slave controller row(s) and entire columns lit on master output array No heat Blown fuse in master/slave Loose wire connection between master and slave controller First check actuators for proper wiring then replace fuse in master/slave controller, 1.25A Check wire and connection between master and slave Constant light in LED array LED on back of room thermostat does not blink during test mode No heat Lack or excessive heat to floor heating system Defective zone actuator Replace zone actuator Lack of heated fluid to system Check heating supply to the system and the circulator pump Faulty battery Bad contacts between battery and thermostat Replace battery/ Adjust connection in thermostat to ensure better contact to battery Defective room thermostat Replace room thermostat Check wiring of power to CFM All output LEDs are unresponsive No heat CFM controller out- None put array blinks rapidly 3 times specifically from a row and column(s) Improper wiring Master controller is defective Replace master controller. Normal operation during test of room thermostat www.danfoss.com DKCD 5/2002 CFR CFZ CFM 24 CFM 230 T 1.25A F 4A CFM CFS 24 CFS 230 CFS T 1.25A + T 0.5A F 4A + T 0.5A www.danfoss.com DKCD 5/2002 GB DK FIN Typical wiring diagram (Europe) Typischer Schaltplan Typisk el-diagram Elanslutning Kytkentäkaaviomalli NL PL CZ Diagramme (Europe) Aansluitschema (Europa) Typical wiring diagram (Applies to the USA & Canada) Przykład schematu połączeń (Europa) Typické schéma zapojení (Evropa) L1 L2 Pump: 115V, 1 phase, 60 Hz, 3A max. L1 L2 T 1.25 A protects outputs T 0.5 A protects controller GB If the regulator is fitted in a metal cabinet or where a wall, a concrete floor or other structural components attenuate the transmission signal from the room thermostats to such an extent that a faulty alarm is triggered, an external antenna, order no. 088H0093, must be used. Wird der Regler in einem Metallschrank oder an einem Ort montiert, an dem die Dämpfung des Signals von den Raumthermostaten durch Wände, Betondecken oder andere Gebäudeteile zu Fehlalarmen führt, so ist eine externe Antenne, Bestellnr. 088H0093, einzusetzen. DK Hvis regulatoren monteres i et metalskab eller hvor væg, betondæk eller andre bygningsdele dæmper sendesignalet fra rumtermostaterne så meget, at der op står fejlalarm, skal der anvendes en ekstern antenne, best. nr. 088H0093. Om regulatorn monteras i ett metallskåp, eller där väggar, betonggolv eller andra byggnadsdelar dämpar sändarsignalen från rumstermostaten så mycket att larmet löser ut, ska man använda en extern antenn, best.nr 088H0093. FIN Jos ohjain asennetaan metallikoteloon tai paikkaan, jossa seinä, betonilattia tai muut rakennusosat vaimentavat huonetermostaattien lähettämää viestiä niin paljon, että järjestelmä antaa vikahälytyksen, on käytettävä ulkopuolista antennia, tuotenumero 088H0093. En cas d’installation du régulateur dans une armoire métallique ou bien à tout autre endroit où un mur, une plate-forme en béton ou d’autres éléments de construction atténuent le signal émis par les thermostats d’ambiance au point de déclencher une fausse alarme, il convient d’utiliser un capteur externe, n° de code 088H0093. NL Als de regelaar in een metalen behuizing wordt gemonteerd of op plaatsen waar een wand, beton of andere delen van een gebouw het zendsignaal van de ruimtethermostaten dusdanig dempt dat er foutalarmen ontstaan, moet er een externe antenne, best.nr. 088H0093, worden gebruikt. FCC ID: PGBTYPE-CFR , CAN 3934104209 This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry Canada and with RSS-210 of Industry Canada: Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. PL Jeżeli regulator znajduje się w metalowej obudowie lub betonowe ściany i stropy osłabiają sygnał wysyłany przez termostaty pokojowe, należy zastosować zewnetrzną antenę (numer katalogowy 088H0093) CZ Pokud je regulátor namontován v kovové skříni nebo na místě, kde dochází ke snížení kvality signálu /stěna, betonový strop nebo jiné části budovy/ je třeba instalovat přídavnou anténu, obj. č. 0088H0093. www.danfoss.com DKCD 5/2002
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Page Count : 3 Create Date : 1910:20:50 12:35:35 Producer : Acrobat Distiller 3.0 for Windows Author : f08661 Title : cfm-cfr_install_oper Subject : cfm-cfr_install_oper Creator : Adobe PageMaker 6.5EXIF Metadata provided by EXIF.tools