Data Critical AVTS1010 AVTS1010 User Manual UserGuide
Data Critical Corporation AVTS1010 UserGuide
Contents
- 1. User Guide
- 2. Service Manual
- 3. Revised Service Manual
User Guide
EXHIBIT U – User Manual FCC ID# NMEAVTS1010 DATA CRITICAL CORP. AlarmView™ Users Guide Document Precautionary Information Caution Instructions - For continued safe use of this equipment, it is necessary that the listed instructions be followed. However, instructions listed in this manual in no way supersede established medical procedures concerning patient care. Intended Use - The system is intended to monitor various patientmonitoring devices for alarm conditions, and responds by transmitting message data that includes text information from the patient. Confirmation - When the system sends out a page, there is NO confirmation back that the intended pager has successfully received the page. Maintenance - Failure on the part of the hospital or institution to maintain the equipment as outlined in this manual may cause pre-mature equipment failure. Installation - The AlarmView System has been installed by qualified technicians. Modification of this installation may cause undue equipment failure. Electromagnetic Interference - The AlarmView System may cause electromagnetic interference with devices operated in close proximity to the transmitter (refer to Appendix C). System Components - Do not spill liquids on any of the AlarmView™ System components. Warnings Patient Monitoring - The most reliable method of patient monitoring combines close personal surveillance with correct operation of monitoring equipment. Patient alarm conditions and notifications are primary functions of the patient monitoring system. It is imperative that the caregiver and/or monitoring floor technicians monitor patient alarm conditions. The AlarmView System is not intended for use as the primary source for the patient alarm notification. Accidental Spills - In the event fluids are accidentally spilled in the equipment, take the equipment out of service and check for damage. Check operation after drying 24 hours later. Antenna Placement - The transmitter unit with a transmitter antenna may interfere with computer equipment with electronic switchboards located close to the antenna. If the transmitter unit must be located close to these types of equipment, a remote antenna should be used. Change of Performance - If the system fails to page users reliably, contact the hospital staff responsible for electromagnetic environment and Data Critical Corp. immediately. (Data Critical Corp. 24 hour support at 1-877-322-7828) Electrical Shock - To reduce the risk of electrical shock, DO NOT remove cover (or back). Refer servicing to qualified personnel. Environment - Data Critical Corporation does not assume responsibility for damage to the equipment caused by improperly vented cabinets, improper or faulty power, or insufficient wall strength to support equipment mounted on such walls. Explosion Hazard - Do not use this equipment in the presence of flammable anesthetics, skin cleaning agents, and disinfectants. Great care must be exercised when the device is used in an oxygen-enriched atmosphere. The atmosphere is considered to be oxygen enriched when the room air contains more than 25% of oxygen or nitrous oxide. Home Use - AlarmView™ System is not intended for home use. Power - Convenience outlets and all others that may be used for the patient must be on the hospital emergency circuit so that they are energized at all times. Site Surveys - Each institution is responsible for surveying existing equipment and ensuring no conflict exists when considering the introduction of additional radiating devices. Transmission Bands - Each institution is responsible for maintaining continued surveillance of transmission bands being used in the facility to prevent co-occupation of bands and cross-band interference. Indications for Use This device is intended for use in real-time monitoring of routine patient status and alarm events on medical devices. It serves as a parallel, redundant mechanism to inform the clinical staff of patient events. It is intended to be a secondary means of annunciating and displaying patient alarm information to mobile healthcare providers. AlarmView is limited to use by qualified medical professionals who have been trained on the use of the device. It is intended for use in hospital and hospital type environments and is not for home use. AlarmView is intended to supplement and not to replace any part of the current device monitoring procedures. AlarmView is not considered in and of itself to be diagnostic without skilled interpretation and does not replace physician’s care. AlarmView is currently validated for use with the N-x9y and the N-3000 data protocols. Please note that we have demonstrated compatibility with the data protocols that Nellcor Puritan Bennett has defined, not the individual monitors. However, for FDA reference, the chart below indicates all models using the protocol. Data Critical is compatible with all the listed monitors. Protocol: All Current Models: N-x9y N-3000 N-290, N-295 N-3000 For devices not listed in the above compatibility chart, a separation distance of 5.5 feet between the AlarmView Transmitter and other emitting devices should be observed. For the devices listed on the above compatibility chart, the AlarmView Transmitter may be placed in either of the configurations described below: • • The AlarmView transmitter can be located remotely from the patient device (e.g. place the AlarmView Transmitter on the wall instead of the patient monitoring equipment). When placing the AlarmView Transmitter in close proximity to the patient monitoring equipment, place it as shown in the drawing below, using the velcro attachment provided: Alarm Data The alarm data that the AlarmView system echoes are listed in the following chart. Alarm Nx9y N3000 SPO2 Upper Limit SPO2 Lower Limit PR Upper Limit PR Lower Limit No Pulse Motion No Pulse No Motion Sensor Disconnect HR Upper Limit HR Lower Limit Asystole ECG Lead Off ECG Cable Off ECG Operations Error ECG Noise RR Upper Limit RR Lower Limit Apnea Respiration Lead Off Respiration Cable Off Respiration Ops Error Respiration Noise Low Monitor Battery It should be emphasized that this alarm data is passed to AlarmView via simple text strings. No interpretation of this information is made. Whatever the monitor passes AlarmView is what will be passed through and transmitted to the nurse. Also, these alarm modes are determined by the protocols we are claiming compatibility with: N-x9y and N-3000. Service and Technical Support Direct all inquires to: Data Critical Corporation 19820 North Creek Parkway Suite 100 Bothell, WA 98011 For technical advice or information concerning any equipment in your AlarmView™ System, contact Technical Support. Call, toll free at 1-877DCC-STAT (1-877-322-7828). Copyright © 1998-1999 Data Critical Corp. All Rights Reserved. Conventions of this Manual Two items that may help you as you work through the AlarmView User’s Guide are the special notes and cautions that appear throughout this text. Individual icons identify these notes and cautions, and they alert you to special information. NOTE The Caution icon alerts you to possible problems that you may encounter as you work through the AlarmView™ System programs. The possibility of losing data, for example, is information that could be mentioned in a caution. The Note icon alerts you to tips or hints that may make it easier for you to work within AlarmView System programs. These might include data entry tips, additional information about a window or field, or recommended procedures. NOTE: Due to continuing product innovation, specifications in this manual are subject to change without notice. Trademarks: Nellcor Puritan Bennett™ are registered trademarks of Nellcor Puritan Bennett, Inc. Windows™ CE is a registered trademark of Microsoft Corporation. AlarmView™ System is registered trademark of Data Critical Corporation. Introduction AlarmView™ System Product Description The AlarmView System is a secondary alarm notification system that transmits alarm data from Primary Patient Monitoring Equipment (PME) to pagers that are worn by caregivers. • The AlarmView Pager - The AlarmView Pager is an off the shelf pager that is worn by caregivers responsible for individual patient care. • The AlarmView Programmer - The AlarmView Programmer is an off the shelf Personal Digital Assistant (PDA) with Windows CE operating system and equipped with AlarmView programming software. The PDA needs to have an infrared (IR) port to communicate with the transmitter. § The AlarmView Transmitter - The AlarmView Transmitter is connected to the Patient Monitoring Equipment (PME) (i.e., Nellcor Puritan Bennett Pulse Oximeter – NPB-290, NPB-295, NPB-3000) with an AlarmView cable that is connected to the PME’s serial port. AlarmView System Diagram AlarmView™ System System Components Transmitter The transmitter is Data Critical Corporation’s proprietary RF transmitter operating in the UHF band (450-466MHz). It has an a BNC connector for the antenna needed for the RF transmissions, an IR port used for setup, a button for power on/off and certain user initiated transmissions, and an RJ-45 connector for connection with the Patient Monitoring Equipment.Pager The pager is a 4 by 20 character text based, off the shelf pager operating in the UHF band (450-466MHz), and able to receive POCSAG encoded pages. PDA (Personal Digital Assistant) Programmer The PDA programmer is an off the shelf Personal Digital Assistant with Windows CE operating system and equipped with AlarmView programming software. The PDA programmer includes an IR port for communications with the transmitter. At least one PDA running Windows CE with AlarmView software is needed to be used for user programming of the transmitters. Monitoring Device Types The AlarmView software is currently configured to be compatible with Nellcor Puritan Bennett Pulse Oximeters N-290, N-295, or N-3000. Getting Started Before turning on the transmitter, ensure that the antenna is attached to the transmitter. The antenna is attached to the transmitter via a BNC connector found on the back of the transmitter (directly behind the LED). The power cable is attached on the back of the transmitter to the far right. The unit can now be turned on by pressing the button on the top of the transmitter. Survey Mode The Survey Mode is a mode in which frequent periodic pages are sent from the transmitter to the assigned pager(s). To begin the Survey Mode, turn on the transmitter, as described above. The transmitter should not be attached to any patient monitoring equipment as this point. The LED on the front of the transmitter will be ORANGE to indicate that the transmitter is attempting to establish communications with the patient monitoring equipment. Press the button on the top of the transmitter, and hold the button down for approximately 5 seconds. A numbered “Survey Page” will be sent. Every 15 seconds, another “Survey Page” will be sent. This will continue until one hundred pages have been sent. To stop the survey mode before one hundred pages have been sent, press the button on the top of the transmitter, and hold the button down for approximately 5 seconds. Pages sent during the Survey Mode will have a line of data, which will indicate that the Survey Mode is in process. Pages sent during the Survey Mode will contain the following data: Bed Number Transmission Number (in sequence) Programming Mode The Programming Mode is the mode in which the PDA is used to change or view the current setup (i.e. the bed number and the pager cap codes) of the transmitter. To program the transmitter, the transmitter must be trying to establish communications with the patient monitoring equipment (the LED is ORANGE), or have established communications with the patient monitoring equipment (the LED is GREEN). The Editor Program Turn the PDA “ON”. The first screen of the PDA will appear and will resemble the screen below. Select the Windows Start menu button. From the Windows Start menu, select the “AV System Manager” program. The AlarmView System Manager main screen will appear as shown below. Tap the About button for information about the System Manager software. Tap the OK Button to return from this dialog box. Now tap the Editor Button on the Main Screen. The following warning will appear. Pressing the “No Button” will return the user to the AlarmView System Manager main screen. Pressing the “Yes Button” will launch the “AlarmView Editor” program. This is the program used to setup which bed number and cap codes are present in the system. It can be reconfigured when pagers are sent back to the factory, or new pagers are obtained. To configure the bed numbers available in the system, tap the Bed Numbers 1 - 24 tab or the Bed Numbers 24 – 48 tab. The first tab lists the first 24 bed numbers available to the system. The second tab lists the last 24 bed numbers available to the system. It is not necessary to fill in all 48 slots. Below is the Bed Numbers 1 – 24 screen. Below is the Bed Numbers 24 – 48 screen. Note that the “active” tab is displayed in all caps. Bed Numbers can be added and deleted from this list. Click on a bed number to edit. Using the stylus, tap the backspace key on the keyboard to delete the bed number to be edited (or highlight the entire bed number as shown below), and using the numbers and letters on the key board, type in the new bed number. Tap the “Save” button on completion, or the “Exit” button to exit the Editor Program. If the key board is not visible, tap the keyboard icon to display the keyboard. If an additional bed number is desired, a bed number can be added to any blank space on page one or two of the bed number listing. Simply tap the cursor in the blank space and begin typing the new bed number. To edit the pager numbers, tap the “Pagers” tab on the upper right of the screen. The “AlarmView Editor” Screen Pagers page will appear. Pager Cap Codes can be added and deleted from this list. Click on a cap code number to edit. Using the stylus, tap the backspace key on the keyboard to delete the cap code number to be edited (or highlight the entire cap code number), and using the numbers and letters on the key board, type in the new cap code number. Tap the “Save” button on completion, or the “Exit” button to exit the Editor Program. If the key board is not visible, tap the keyboard icon to display the keyboard. If an additional bed number is desired, a bed number can be added to any blank space on page one or two of the bed number listing. Simply tap the cursor in the blank space and begin typing the new bed number. Note that the global cap code value can not be changed by the user. To restore values to the state they were in before editing began, tap the Restore Button on any of the pages before pressing the Save Button. Once the Save Button has been pressed, however, the original values are not restored. When the “Editor Program” is exited, the Main Screen is again displayed. The Configuration Program If the main PDA screen is displayed, tap Windows Start menu button. From the Windows Start menu, select the “AV System Manager program. The AlarmView System Manager main screen will appear as shown below. To launch the Configuration Program, tap the Programming button. The “Configuration Program” Main Screen will appear. This program is used to change the transmitter’s setup of bed numbers, cap codes, alarm severity, and reminder page interval. It also displays information that can not be modified by the user. This information includes: monitor identifier (N3000, N295, N290), transmitter number, hardware version, software version, protocol version, authorize identification, paging frequency, and paging baud rate. This program can be used at shift change, or whenever there is a need to change/view the current transmitter configuration. To obtain the current configuration programmed into the transmitter, tap the “Download Configuration Button”. When this button is tapped, the PDA attempts to establish communications with the transmitter. If the IR port could not be accessed, the following dialog box will be displayed. Tap the OK button to close this dialog box and return to the Configuration Program main screen. If the IR port could be accessed, but communications could not be established between the PDA and the transmitter, the following error dialog box will be displayed: When “OK” is tapped on this dialog box, the Configuration Program main screen will be displayed with a status message informing the user of a “Failed to Connect” status. At this point, simply point the PDA at the transmitter, and tap the “Download Configuration Button” again. While the transmitter is being queried, the Configuration Program main screen will be displayed with a status message informing the user of a “Loading Data” status. The PDA will be in this state for less than 2 seconds. When the transmitter has been successfully queried, the Configuration program main screen will be displayed with a status message informing the user of a “Transmitter Data Loaded” status. At this point, if the displayed data is correct, no changes need be made, and the user is done. Exit the Configuration Program by tapping the “X” in the upper right corner of the screen. If the data needs to be changed, the Patient Bed Number can be selected by tapping on the bed number drop down list, and highlighting the desired bed number. A maximum of two pagers can be selected by clicking the radio button next to the desired pager number. To change/view alarm severity selection or reminder page intervals, tap the Advanced Setup Button on the upper left of the screen. If no data has been previously downloaded, the PDA will attempt to establish communications with the transmitter. When the data is downloaded, the following screen will appear. Alarm Severity selections: Send All Alarms indicates that all alarms will be sent to the pagers regardless of the severity of the alarms. Only Critical Alarms indicates that only critical (high prioirty and medium priority) alarms will be sent to the pagers. Reminder interval indicates the time interval at which reminders will be sent after the original alarm has not been silenced. Tap the OK button when all changes have been made. To view transmitter data that can not be modified by the user, tap the Current Configuration Button on the upper left of the screen. If no data has been previously downloaded, the PDA will attempt to establish communications with the transmitter. When the data is downloaded, the following screen will appear. Tap the “Program Transmitter” button to program the transmitter with the newly selected values. If no bed number was selected before the “Program” button was tapped, the following error dialog box will appear. If no cap code was selected before the “Program” button was tapped, the following error dialog box will appear. Exit both of the above dialog boxes by tapping the OK Button. After the above error conditions are rectified, tap the “Program Transmitter” button again. When this button is tapped, the PDA attempts to establish communications with the transmitter. If the IR port could not be accessed, the following dialog box will be displayed. Tap the OK button to close this dialog box and return to the Configuration Program main screen. If the IR port could be accessed, but communications could not be established between the PDA and the transmitter, the following error dialog box will be displayed: When “OK” is tapped on this dialog box, the Configuration Program main screen will be displayed with a status message informing the user of a “Failed to Connect” status. At this point, simply point the PDA at the transmitter, and tap the “Program Transmitter Button” again. While the transmitter is being queried, the Configuration Program main screen will be displayed with a status message informing the user of a “Programming” status. The PDA will be in this state for less than 2 seconds. When the transmitter is successfully programmed, the Configuration Program main screen will be displayed with a status message informing the user of a “Programming Successful” status. A “Programming Successful” page will also be sent to the newly selected pagers, displaying the newly selected bed number. Exit the “Configuration” program by tapping the “X” in the upper right corner of the screen. When the Configuration Program has been exited, the System Manager Program main screen will be displayed as shown: Exit this program by tapping the Exit Button in the upper left of the screen. Communicating With Patient Monitoring Equipment Turn on the transmitter, as described above. Attach the serial cable to the RJ-45 port. Attach the other end of the cable to the patient monitoring equipment. The transmitter will automatically detect the monitor (assuming it is an N-3000, N-295, or N-290). Once communications have been established with the patient monitoring equipment, a page will be sent to the pager indicating this, and the LED will turn GREEN. The communications established page will have the following data: Bed: xxxxx Comms OK From that point, all alarms at the patient monitoring equipment will be sent to the pager(s), as assigned by the PDA (as described above). Turn on the transmitter, as described above, and establish communications with the patient monitoring equipment (the LED will be transmitter (but, do not hold it down). A “Test Page” will be sent indicating the current patient data (SPO2, and Pulse Rate). Note that Test Page Bed: xxxxx SPO2: xxx The transmitter can only be turned off if it is not communicating with the patient monitoring equipment (i.e. the LED is RED). To turn off the goes off. Communications Not Established Turn on the transmitter, as described above. The transmitter should not be attached to any patient monitoring equipment as this point. The LED on the front of the transmitter will be ORANGE to indicate that the transmitter is attempting to establish communications with the patient monitoring equipment. After 10 seconds of no communications, a page will be sent indicating that no communications have been established. Bed: xxxx Comm Fail Retrying Every 10 minutes after that, another page will be sent indicating that communications have not been established. This will continue for one hour. At this point, a page will be sent indicating that the transmitter is turning off. Bed: xxxx Comm Fail Tx Shut down Low Battery Warnings If the battery becomes too low for proper transmitter functioning, an alarm will be sent indicating the low battery situation, and the transmitter will be shut down. Bed: xxxx Low Tx Battery Tx Shut down Appendix A Electromagnetic Interference It is a known fact that electronic devices that emit radio frequencies may interfere with the operation of other electronic devices. This has become proliferation of intentional electronic radiators such as cellular phones, paging systems, walkie-talkies, and wireless network LANs. The critical are of special concern and incidents have been observed with apnea monitors, wheel chairs, and ventilators. to address this complicated issue through their respective working groups. The ANSI C63.6 working group made up of industry and the means to evaluate critical care medical devices for electromagnetic interference problems by the clinical and biomedical staff using an ad EMI fundamentals. A possible outline for management of potential EMI sources and education of the hospital staff is as follows: environment of their hospital and take actions on: • managing (increasing) distance between sources of EMI and susceptible devices managing use of frequencies close to StatView™ System • • EMI lower power from internal EMI sources under hospital control (paging systems) labeling devices susceptible to EMI • • • • educating staff (nurses and doctors) to be aware of, and to recognize, potential EMI related problems conducting technical remedial action to eliminate EMI, such as shielding sharing relevant EMI/EMC information with others, especially in evaluation of new equipment purchases which may have emissions identifying critical areas where life-support devices are in use and restricting the use of personal communicators (cellular phones) in those critical care areas Purchase critical care devices that comply with IEC 601-1-2 EMC standards: • the required level of EMI immunity is 3 volts per meter • the interference level that a medical device can radiate (emit) is 0.0014 volts per meter The AlarmView™ System has a transmit power level of up to 1 watt peak at a pre selected RF frequency between 450 MHz to 466 MHz Protection Distance Estimate Immunity of Medical Device of 2 V/meter 1 watt x ft xm x ft xm x ft xm Appendix B Terms Glossary BNC Connector: A type of connector used with coaxial cables. The basic BNC connector is a male type mounted at each end of a cable. This connector has a center pin connected to the center cable conductor and a metal tube connected to the outer cable shield. A rotating ring outside the tube locks the cable to any female connector. This is the type of connector that the antenna uses to connect to the transmitter. IR Port: Infrared port. An IR Port is used by the PDA to communicate with the transmitter. PDA: Personal Digital Assistant (Win CE Device) POCSAG: Post Office Code Standardization Advisory Group – the protocol used for pager communications RF Transmissions: Radio Frequency transmissions RJ-45 Connector: Short for Registered Jack-45, an eight-wire connector commonly used to connect computers. Looks similar to the connectors used for connecting telephone equipment, but they are somewhat wider. UHF Band: Ultra High Frequency Bandwidth Windows CE: The operating system of the PDA
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Creator : Microsoft Word Create Date : Tuesday, January 25, 2000 9:01:45 AM Title : UserGuide.PDF Author : Unknown Producer : Acrobat PDFWriter 3.02 for Windows Subject : Modify Date : 2000:07:21 10:30:33 Page Count : 48EXIF Metadata provided by EXIF.tools