Datalogic ADC RSB Falcon 4410 and and Falcon 4420 User Manual

Datalogic ADC, Inc. Falcon 4410 and and Falcon 4420

Contents

User Manual 1

Falcon® 4400 Serieswith Windows® CEFalcon 4410 26-Key modelFalcon 4420 48-Key model Falcon 4410 52-Key NU model Quick Reference Guide
Datalogic Mobile, Inc1505 Westec Dr.Eugene, Oregon  97402Telephone: (541) 743-4800Fax: (541) 743-4900An Unpublished Work - All rights reserved. No part of the contents of this documentation or the procedures described therein may be reproduced or transmitted in any form or by any means without prior written permission of Datalogic Mobile, Inc. or its affiliates or subsidiaries ("Datalogic" or “Datalogic Mobile”) . Owners of Datalogic prod-ucts are hereby granted a non-exclusive, revocable license to reproduce and transmit this documentation for the purchaser's own internal business purposes. Purchaser shall not remove or alter any proprietary notices, including copyright notices, contained in this documentation and shall ensure that all notices appear on any reproductions of the documentation.Should future revisions of this manual be published, you can acquire printed versions by contacting your Datalogic representative. Electronic versions may either be downloadable from the Datalogic Mobile website (www.mobile.datalogic.com) or provided on appropriate media. If you visit our website and would like to make comments or suggestions about this or other Datalogic publications, please let us know via the “Contact Datalogic” page.DisclaimerDatalogic has taken reasonable measures to provide information in this manual that is complete and accurate, however, Datalogic reserves the right to change any specification at any time without prior notice.Datalogic is a registered trademark of Datalogic S.p.A. and the Datalogic logo is a trademark of Datalogic S.p.A. all licensed to Datalogic Mobile, Inc. All other trademarks and trade names referred to herein are property of their respective owners.Falcon® is a registered trademark of Datalogic Mobile, Inc. and of its wholly owned subsidiaries.Microsoft Windows®, Windows® 2000, Windows®CE, Windows® NT, Windows® XP and the Windows logo are registered trademarks of Microsoft Corporation.PatentsThis product may be covered by one or more of the following patents: 4,861,972 • 4,866,257 • 4,879,456 • 5,198,649 • 5,208,449 • 5,212,372 • 5,247,161 • 5,311,000 • 5,440,110 • 5,481,098 • 5,493,108 • 5,508,505 • 5,664,231 • 5,671,374 • 5,686,716 • 6,041,374 • 6,412,698 • 6,415,978 • 6,454,168 • 6,478,224 • 6,513,714 • 6,536,670 • 6,561,427 • 6,585,157 • 6,923,377 • 7,108,170 • D377345 • CA2,188,399 • Other U.S. and Foreign Patents Pending.
Quick Reference Guide                            1Table of ContentsFalcon® 4400 Series with Windows® CE ............................................................. 3Overview ......................................................................................................................3Getting Started ..............................................................................................................4Features of the Falcon   ...................................................................................................4Powering the Falcon  .......................................................................................................8Getting Started ..............................................................................................................8Battery Pack  ...........................................................................................................8Power Supply  ..........................................................................................................9Installing the Battery Pack   ..................................................................................... 10Checking Battery Power  .......................................................................................... 12System Tray Battery Status Indicators ...................................................................... 12Charging the Batteries ............................................................................................ 13Charging with a Battery Charger  .............................................................................. 14Charging with the Dock ........................................................................................... 14Backup Battery ...................................................................................................... 15Battery Discharge Characteristics   ............................................................................ 15Setting Up the Mobile Computer ..................................................................................... 16Touchscreen Calibration .......................................................................................... 16Getting Connected  ................................................................................................. 16Setting the Date and Time  ...................................................................................... 19Entering Data  .............................................................................................................. 19Using the Stylus  .................................................................................................... 20Navigating the Display ............................................................................................ 22Keypads ............................................................................................................... 24Scanning Bar Codes  ..................................................................................................... 31Laser Scanning ...................................................................................................... 31Bar Code Scanning with 2D Imager  .......................................................................... 33Image Capture  ............................................................................................................ 34Flash Memory .............................................................................................................. 35Saving to Flash ...................................................................................................... 35Flash FX Location ................................................................................................... 35FlashFX Disk Size ................................................................................................... 36Context Sensitive Help .................................................................................................. 37Resetting the Falcon ..................................................................................................... 38Warm Reset  .......................................................................................................... 38Cold Reset  ............................................................................................................ 39Maintaining the Falcon .................................................................................................. 41
Table of Contents2Falcon® 4400 Series with Windows® CETroubleshooting ...........................................................................................................41RF Connectivity Troubleshooting .............................................................................. 45Technical Support  ........................................................................................................46Datalogic Mobile Website Support .............................................................................46Datalogic Mobile Website TekForum ..........................................................................46Reseller Technical Support  ...................................................................................... 46Telephone Technical Support  ................................................................................... 46Appendix A: Datalogic Mobile Falcon® Windows® CE Series End User License Agreement .......................................................................  47Appendix B: Microsoft® Windows® CE End User License Agreement  ....................................................................... 50Appendix C: Datalogic Mobile Falcon® Windows® CE Product Series Warranty........................................................  51Appendix D: Safety Information  ........................................................................ 52Laser Safety Label ........................................................................................................52Advisory Statement ................................................................................................ 52Regulatory Statements  .................................................................................................52Radio Frequency Interference  .................................................................................. 52Canadian Compliance Statement .............................................................................. 52Appendix E: Laser Safety ................................................................................... 53International Caution Statements for CLASS 1, 2, 3R, II, and IIA Laser Devices ....................53English .................................................................................................................53French ..................................................................................................................53German ................................................................................................................54Italian ..................................................................................................................54Danish ..................................................................................................................54Dutch ...................................................................................................................55Swedish ................................................................................................................55Finnish .................................................................................................................56Norwegian ............................................................................................................56Portuguese ............................................................................................................ 56Spanish ................................................................................................................57Chinese ................................................................................................................57Japanese ..............................................................................................................58
Quick Reference Guide  3Falcon® 4400 Serieswith Windows® CEOverviewThe Falcon® 4400 combines the fle xibility of Windows® CE with the power of the Intel XScale processor, WiFi wireless technology, a large color display, laser (1D) and imaging (1D and 2D) scanning in an ergonomic PDT. The Fal-con® 4400 series is designed for warehouses, distribution centers, retail in-store environments, and other inventory management applications requiring maximum performance and durability.New options available for the Falcon 4400 include 128/128 memory, a full alphanumeric Numbers Up Keypad, and a high-density 2D scan engine. Overmolded models will handle 5’ / 1.5M drops to concrete, and have an IP54 environmental rating; and an 86dBA (at 24") / 100dBA (at 10 cm) beeper. The Falcon® 4400 will handle demanding data collection tasks in industrial environments.The Falcon Management Utility (FMU) and Falcon Desktop Utility (FDU) are included with every unit, providing remote management and configurabil-ity.This Quick Reference Guide contains the following sections:• Features of the Falcon on page 4 — describes the functions and keys of the Falcon.• Powering the Falcon on page 8 — gives information about the batteries, shows how to install the battery pack, and provides options for charging.• Setting Up the Mobile Computer on page 16 — tells how to calibrate the Touchscreen, set up the radio cards, and set up other options.• Entering Data on page 19 — using the stylus, navigating the display, about keypads, and bar code scanning.•Flash Memory on page35 — about the Flash FX disk.• Context Sensitive Help on page 37 — accessing Help from the Falcon.• Resetting the Falcon on page 38 — describes warm and cold resets.
Getting Started4Falcon® 4400 Series with Windows® CE• Troubleshooting and Datalogic Mobile Technical Support starting on page 41.Getting StartedBefore using the Falcon for the first time, you must install the battery pack into the Falcon, then charge both the battery pack and the backup battery. See Installing the Battery Pack on page 10 for instructions.Features of the Falcon Four perspectives of the Falcon® 4400 mobile computer are shown. Refer to Table 1 on page 7 for a list of the illustrated parts with references to more detailed information.CAUTIONYou must charge the battery pack and backup battery in a dock or with a powercable prior to your first use of the Falcon. The initial charge time is approximately24 hours. See Charging the Batteries on page 13 for more information.
Features of the FalconQuick Reference Guide  5Figure 1. Falcon Front View and Connector ViewFor a complete description of each key on the Falcon, refer to page 24. Touchscreen DisplayHandleFalcon 44xx26-Key Key-padUSB/Serial ConnectorStrap Studsw/RubberBumpersFalcon 4420Handled modelResetPower KeyLED Scanning/Charging Indicator
Features of the Falcon6Falcon® 4400 Series with Windows® CEFigure 2. Falcon Scanner and Battery Door ViewsFor more information, please refer to the Falcon® 4400 Windows® CE Mobile Computer Product Reference Guide (PRG), located on the Falcon 4400 Product CD that came with your device.Strap StudsTriggerHandleStylusTether/Lanyard PortStylus HolderBattery DoorSpeakerBattery Door Latch (2 each)Scanner Aperture
Features of the FalconQuick Reference Guide  7Figure 3. Model comparisonTable 1. Features of the Falcon Feature Function/Description More InformationBattery Door Rotate the latches to unlock the battery door so the battery pack can be removed.Figure 4,page 10Display/Touch ScreenThe equivalent of a PC monitor for viewing and interacting with the current application. This display is touch-sensitive; use it like you would a mouse on a PC.Figure 1,page 16,page 22Handle The Falcon 442X comes with a handle that is ergonomically designed for ease of use with a scanner trigger.  Figure 1Reset key Insert an object, such as a paper clip, into this hole to perform a cold reset of the unit. Datalogic recommends that you attempt a warm reset first.Do not use a sharp object, or you could disable the reset function, puncture the keypad’s industrial seal, and void your warranty. page 38Keypad Use the alpha-numeric, function, and navigation keys on the keypad to enter numbers, letters, symbols and navigate with the keypad. page 24Lanyard Port Insert a lanyard to secure a Falcon to a person or work station. page 6Scanner Aperture The laser or imaging scanning beam is emitted from this aperture.  page 31LED When scanning, a red LED indicates the laser is on and a green LED indicates a good read. When the Falcon is charging in the dock, a red LED on the Falcon indi-cates charging and a green LED on the Falcon indicates fully charged. Figure 1Power Key Press the Power key to turn the Falcon on and off, or to toggle the device between suspend (sleep) mode and resume (on).Figure 1,page 24SpeakerThe speaker plays *.WAV and other media files, emits beeps or tones to indicate errors or good reads when bar code scanning and inputting data using the keypad or stylus.Figure 2Strap Studs The Falcon 441X comes with a handstrap that connects to the strap studs.  Figure 2Model 4420Model 4410  Model 4420 with Tethered Stylus
Powering the Falcon8Falcon® 4400 Series with Windows® CEPowering the FalconGetting StartedBefore using the Falcon for the first time, you must install the battery pack into the Falcon, then charge both the battery pack and the backup battery. See Installing the Battery Pack on page 10 for instructions.Battery PackThe battery pack in the Falcon is a 3.7 V, 2000 mAh Lithium Ion battery pack. You will be alerted with a message dialog box when the bat-tery pack reaches a low state. After charging the first time, a complete charge takes about four (4) hours depending on the bat-StylusUse the stylus for navigation, the soft input panel (SIP), and to select items on the touch screen. Place the stylus in the holder after use so you don’t lose or misplace it. An optional Stylus Tether is available for all models.Figure 10, page 20Feature Function/Description More InformationCAUTIONYou must charge the battery pack and backup battery in a dock or with a powercable prior to your first use of the Falcon. The initial charge time is approximately24 hours. See Charging the Batteries on page 13 for more information.3.7VLi-ionCAUTION:  Battery can explode, leak or catch fire if exposed to high temperature, water or fire. Do not short circuit, open or disassemble battery. Recycle or dispose of properly.2000mAh5-1764Product of USAU          S
Getting StartedQuick Reference Guide  9tery pack’s state and the recharging method. A sample battery pack label is shown at the right.Power SupplyUse only the authorized power supplies, battery packs, chargers, and docks supplied by your Datalogic reseller. The use of any other power supplies can damage the Falcon and void your warranty. CAUTIONYou must charge the battery pack and backup battery in a dock or with a powercable prior to your first use of the Falcon. The initial charge time is approximately24 hours.If you remove the battery pack or it fails, there is a 30 minute window in which toinsert a charged battery pack before the backup battery fails. If your backup bat-tery fails, the contents of the RAM memory will be lost. If your back-up battery isless than fully charged, there is a proportionally smaller window of time available.Usage time will be reduced, also.Always charge the battery pack within the temperature range of 32°–113°F (0°–45°C).WARNINGLithium-ion battery packs may get hot, explode, ignite, or/and cause serious injury ifexposed to abusive conditions.• Do not place the battery in or near fire, direct sunlight, or other high tempera-ture locations, or heat the battery.• Do not install the battery backwards so the polarity is reversed.• Do not connect the positive terminal and negative terminal of the battery to each other with any metal object (such as wire or coin).• Do not expose the battery to liquids, or allow the battery to get wet.• Do not disassemble, modify, or pierce the battery. The battery contains safety and protection devices, which, if damaged, may cause the battery to generate heat, explode or ignite.In the event the battery leaks and the fluid gets into your eye, do not rub the eye.Rinse well with water and immediately seek medical care. If left untreated, the batteryfluid could cause damage to the eye.Datalogic recommends annual replacement of rechargeable battery packs toensure maximum performance.
Getting Started10 Falcon® 4400 Series with Windows® CEModels require either a Listed class II or class III with a Limited Power Source (LPS). For the safety certification to be valid, class III input power sources must be IEC/EN60950-1 (EN 60335-series, EN 60065 or relevant) approved.- For single Docks and battery charger -Input: 100 - 240 VAC Output: 12 VDC Max. Current: 2.5 A Max. Power: 30 W- For 4-slot Docks -Input: 100 - 240 VAC Output: 12 VDC Max. Current: 5.0 A Max. Power: 60 WInstalling the Battery Pack When you first remove the Falcon from the box, you must charge both the battery pack and the backup battery for a minimum of 24 hours. Complete the following instructions to install the battery pack:1. On a 441X, detach the elastic handstrap by releasing its hook from the strap studs at the base of the unit (refer to the PRG).
Getting StartedQuick Reference Guide  11Figure 4. Installing the Battery Pack2. Turn the battery door latches to unlock the battery door. Remove the door.3. Insert the battery pack with the pull tab on the outside and the bat-tery contacts aligned with the matching contacts inside the battery compartment. The battery pack has a keying feature on one side to prevent incorrect installation (refer to Figure 4). 4. Replace the battery door by inserting the bottom tab into the slot. If the battery pack is installed incorrectly, the door will not seat properly.5. Rotate the battery door latches on the battery compartment cover towards the base of the unit.6. On the 441X, replace the handstrap hook on the strap stud at the base of the unit.Battery DoorCover Plate (unit may have Handle here instead)FalconBattery Door LatchesUnhook/hook Strap As NeededBatteryPlastic Pull TabStrap Studs
Getting Started12 Falcon® 4400 Series with Windows® CEChecking Battery PowerIf you remove the battery pack or the battery fails, you have about 30 minutes to swap in a new battery pack or charge the battery pack before the backup battery fails (if the backup battery has been fully charged).System Tray Battery Status IndicatorsThe System Tray displays icons to show the status of some battery conditions, as shown in Table 2. Table 2. System Tray Battery Status IndicatorsBattery Status IconsBattery Status Icon DescriptionBackup Battery Low Conditionno icon The battery status is updated in the control panel, but no icon is displayed.Backup Battery Very Low ConditionWhen the backup battery is very low, the system tray contains a very low backup battery CAUTION icon. In addition, a dialog box pops up and alerts you that the backup battery is very low and needs to be charged. The dialog comes up every five minutes until you charge the backup battery.Battery Charging ConditionThis icon indicates that the battery pack is currently charging.Battery Low Condition This icon indicates that the battery pack is low.Battery Very Low ConditionWhen the battery pack is very low, the system tray shows a very low battery CAU-TION icon. Also, a dialog box pops up and alerts you to charge the battery pack. A battery warning dialog will pop up every five minutes until you charge the battery.Battery Power GaugeThe Power control applet displays a battery power gauge. Start > Settings > Control Panel > Power. Discharged Battery Condition no iconWhen the battery is totally discharged, the battery sensor initiates a shutdown of all applications, and closes the RF Network connection. If the battery pack has com-pletely discharged, when the battery pack is charged or replaced, the unit will resume as before after a cold reset. Refer to Flash Memory on page 35 regarding the data loss of applications and data stored in RAM.Main batteriesRemaining power:0 100
Getting StartedQuick Reference Guide  13Charging the BatteriesThere are several methods for charging the battery pack and backup battery. LEDs on the Falcon, the Single-Slot Dock, Four-Slot Dock, and Four-Slot Battery charger give visual indication of the charge state. Table 3 gives an over-view of all the LEDs and what they indicate.Table 3. Battery Charging Methods and IndicationsCharging Location:Falcon seated in a Dock (Single or Four-Slot)Falcon connected to an external power supplyCharging slot of Dock (Single or Four-Slot)Four-Slot Battery ChargerCharging Duration 4-6 hours 4-6 hours 3-5 hours > 3 hoursBattery Pack Charge Indication: Charging: REDFully Charged: GREEN Charging: REDFully Charged: GREENN/A N/AFalcon Charge LEDDock or Charger Battery Charge LED(s)No effect No effectCharging: Solid RED Fully charged: GREEN*Fault: Flashing REDCharging: LEDs are AMBERFully charged: LEDs are GREENSimultaneously Charges Backup Battery?YES YES NO NO* Refer to page 45 for more information.PDTChargeLEDPDT Charge LEDSpareBatteryChargeLEDCharge Indicator LEDs
Getting Started14 Falcon® 4400 Series with Windows® CECharging with a Battery Charger A LiIon Four-Slot Battery Charger is available to charge batteries indepen-dently from the Falcon. To use, align the battery contacts with those in the Charger and insert them into the slots. Figure 5. Four-Slot Battery Charger Charging with the DockThere are two models of docks for the Falcon: a Single-Slot Dock and a Four-Slot Dock. On both models, an external power supply (AC adaptor) provides power to the dock. Falcons communicate with the host PC using Microsoft ActiveSync protocol either via a USB port or via a serial port. There are two methods for charging a battery pack using a Single-Slot Dock. Refer to Table 3 on page 13 to view methods of battery pack charging using the dock, charge duration, dock status indicators and their purpose. For more information on the dock, refer to the Dock Operating Instructions that come with each dock.Power Indicator LEDUse only the correct battery chargers and docks with this Windows CE color Fal-con. This technology used for these models is incompatible with other DatalogicMobile Falcon chargers and docks, including the Falcon 4410/4420 monochromemodels.
Getting StartedQuick Reference Guide  15Figure 6. Charging the Battery Pack in a Single-Slot DockRefer to Table 3 on page 13 for a list of LED indicators and their purpose. Refer to the PRG for additional information on storage and disposal of batter-ies. Backup BatteryThe 3V Lithium Backup Battery receives its charge from the Battery Pack. To retain date, time, data, and other settings for the Falcon, maintain at least a minimal charge on the Battery Pack.When the backup battery is low, an icon will display on the status bar (see Table 2 on page 12), and a dialog box will open to alert you.Battery Discharge Characteristics Battery discharge characteristics vary from eight to nine and a half (8-9.5) hours, depending upon device usage, number of scans per minute, backlight usage, and other factors that draw upon battery power.Spare Battery LEDPower LEDPower PortRS-232 Serial PortUSB PortBattery TabUSB/Serial ConnectorBattery Pack in Spare Battery Charging SlotTop/Rear View of Single-Slot DockBattery Pack in Spare Battery Charging Slot
Setting Up the Mobile Computer16 Falcon® 4400 Series with Windows® CESetting Up the Mobile ComputerAt first use or after a cold reset, the unit will go through a series of initial bootup sequences. Each of these sequences are described as noted:1. Touchscreen Calibration, illustrated in Figure 7.2. Getting Connected on page 16.3. IP Network Setup on page 17.4. Setting the Date and Time on page 19.Touchscreen CalibrationFigure 7. Touchscreen Calibration Getting ConnectedBluetooth Setup1. Open the Bluetooth control panel at Start > Settings > Control Panel > Bluetooth Manager.2. Search for available Bluetooth Devices by tapping the button for the type of device you want (Printer, Serial or All) .3. Create a pairing by double tapping the listing for the device you want and selecting the service. If you want to specify encryption or require authentica-tion, enable the appropriate checkbox.4. TapOK to complete.For detailed instructions, reference the PRG.Follow the on-screen directions to cali-brate the touchscreen. For more information on touchscreen calibration, refer to the PRG.
Setting Up the Mobile ComputerQuick Reference Guide  17Connecting to a PCIn order for the Falcon to communicate with a host PC, Microsoft® ActiveSync must be installed on the computer. Go to www.microsoft.com/downloads/ for information. Reference the PRG for detailed instructions.Installing the USB DriverSo the Host PC can communicate with the Falcon, install the USB driver file from the CD that came with the Falcon, or download it from the Datalogic website. Follow the directions on the CD, or use the following instructions:1. Microsoft® ActiveSync must be installed on your computer before pro-ceeding. Go to www.microsoft.com for information.2. Copy the current USB driver file from the Falcon CD to the C:\Pro-gram Files\Microsoft ActiveSync\Drivers.3. Connect the USB cable to the Falcon or place the Falcon in the dock.4. Connect the USB cable to the Host PC.5. Follow directions on screen. The specified source directory is the one identified in step 2.Serial Cable Setup1. To connect the Falcon using a Serial cable, go to Start > Settings > Control Panel > PC Connection.2. If not already checked, select Enable direct connections to the desktop com-puter. 3. Tap Change Connection and select Serial from the dropdown box.4. Tap OK.IP Network Setup1. Select Start > Settings > Network and Dialup Connections.2. Double-tap on the item (varies based on the radio installed and the number of connections).3. Complete the two tabs (shown in Figure 8):
Setting Up the Mobile Computer18 Falcon® 4400 Series with Windows® CEFigure 8. Modifying Network Connection Settings. •IP Address: Select DHCP or set static IP settings.•Name Servers: If using static IP, set DNS and WINS servers.RF Setup (Summit Client Utility)The Summit Client Utility (SCU) is an application designed for users and administra-tors of mobile devices that use a Summit radio module. Using SCU, you can:• Disable and enable the radio (turn it off and on)• View the contents of configuration profiles, or configs, each of which houses the RF, security, and other settings for the radio• Select the config to be used to connect to a WLAN• View global settings, which apply to every config• View status information on the radio, the access point (AP) or WLAN router to which it is connected, and the RF connection or link between the two• Troubleshoot a connection or performance issue, view in-depth diagnostic information on the connection and the radio, and perform various trouble-shooting and diagnostic tests1. To launch the utility, go to Start > Settings > Control Panel.2. Tap on the Wi-Fi icon.For more detailed information on making changes to settings, please refer to the PRG.
Entering DataQuick Reference Guide  19Setting the Date and TimeTo set or change the date and time, complete the following steps:Figure 9. Setting the Date and Time Entering DataTo open applications, select Start > Programs to display a list of available pro-grams. If the program has an icon on the desktop, double-tap to open it. There are several ways to enter data with the Falcon:• Use the keypad. Refer to Keypads starting on page 24.• Use the stylus on the touchscreen display. Refer to Using the Stylus on page 20 for more information on using the stylus.• Use the soft input panel (digital keyboard) with the stylus. Refer to Soft Keypad/Input Panel on page 23.• Select text in the same way you select text on a PC. Use the stylus to highlight the desired text by dragging the stylus across the desired text, double-tapping to select one word, and triple-tapping to select an entire line.• Use the bar code scanner to enter data. Press the trigger or scan button to initiate a scan. The scanned data will be entered into the current 1. From the Start menu, select Settings > Control Panel > Date/Time to open the Date/Time Properties control panel. Use the arrows in the application to navigate, increase or decrease the time or date.2. Select the year to open a field where you can change the year by backspac-ing, or entering a new year.3. Select the month to open a pull-down list of months. 4. Tap the checkbox to Automatically adjust clock for daylight savings time, if desired.
Entering Data20 Falcon® 4400 Series with Windows® CEapplication’s open file. Refer to Scanning Bar Codes starting on page 31 for more information on using the scanner.• If your Falcon has the 2D Imaging module installed, you can read and decode traditional 1D linear bar codes, 2D and composite symbols. You can also capture images such as signatures, labels, and other items. See Bar Code Scanning with 2D Imager starting on page 33 for fur-ther information.Using the Stylus The stylus is located next to the scanning pod as illustrated in Figure 10. The stylus on the Falcon is the equivalent of the mouse on a PC. Use the stylus to:• Navigate the touchscreen display.• Select characters in the soft input panel (SIP).• Select applications from the desktop or system tray.• Select tabs, fields and text within applications and dialog boxes.Figure 10. Back View of a Falcon 4420 with a Stylus Never use a pen, pencil, or other sharp object on the Falcon’s touchscreen dis-play. Use only the supplied stylus or plastic-tipped pens intended for use with atouch-sensitive display. Contact your reseller to replace a missing stylus; refer tothe Datalogic Mobile website listed on the back cover of this manual. Stylus Stylus Holder
Entering DataQuick Reference Guide  21It is good practice to replace the stylus into the holder after each use so you don’t misplace it. An optional Tethered Stylus is also available, preventing acci-dental loss of the stylus.Figure 11. Tethered StylusTethered Stylus
Entering Data22 Falcon® 4400 Series with Windows® CENavigating the DisplayThere are several navigation areas on your display, including the command bar, and task bar. Each of these navigation areas have sub-areas of navigation as well. Take the time to familiarize yourself with these features to save yourself valuable time.The Command BarUse the Command bar at the top of the screen to perform tasks in programs, such as opening a file, saving a file, or editing a file. Refer to Figure 12, to view the Command bar.Figure 12. Application NavigationTask Bar (Bottom)Command Bar (Top)Extras Menu Button (Open Applications)System TraySoft Input PanelNavigation ArrowStart ButtonNetwork ConnectionBattery Charging IndicatorActive Application WindowDesktopApplication IconsKeyboard Indicator
Entering DataQuick Reference Guide  23The Task BarThe Task bar at the bottom of the screen displays the start menu icon, an icon for the active program, the current time, and system icons for utilities loaded in memory, including the keyboard icon, which opens and closes the soft input panel (SIP). Start Button. Tap the Start button ( ) to open the Start menu. The Start menu includes access to Programs, Favorites, Documents, Settings, Help, and the Run command. From Settings you can access the Control Panel, Network and Dial-up Connections, and the Taskbar and Start Menu configuration.System Tray. The System Tray contains icons for key presses, utilities and applets running in the background. Tap the small arrow(s) in the System Tray to view icons for current input mode(s), keypress, power management, and network connections.Soft Input Panel. Refer to Soft Keypad/Input Panel, below, for details.Extras Menu. Tap the Extras Menu button at the far right of the Task bar to select from a list of open applications or to access the desktop while leaving a program open. Soft Keypad/Input PanelIn applications that accept keyed input, the soft input panel (SIP) can be used to enter data using the stylus. The SIP is a digital, QWERTY-style keyboard.Figure 13. Soft Input PanelSoft Input Panel Keyboard Icons
Entering Data24 Falcon® 4400 Series with Windows® CETo open the SIP:  Tap the Keyboard icon to open the menu and select Key-pad from the pop-up menu to open the keyboard To close the SIP: Tap the Keyboard icon to open the menu and select Hide Input Panel to close the keyboardUse the stylus to select letters, numbers, or symbols from the Soft Input Panel for the current application. Tap the   key to change the keypad to show international letters.KeypadsOverviewThe Falcon is available with several different keypad models: • 26-Key Keypad on page 27• 48-Key Keypad on page 28• 52-Key Keypad on page 29• 52-Key Numbers Up (NU) Keypad on page 30• 5250 Keymap on page 30Refer to the PRG for information on configuring the keypads.Keypad AttributesThere are a number of keys that are common to the different keypad models. Tabl e 4 lists special function keys that are found on several keypads, as well as those which are unique to specific keypads.Table 4. Keypad Overview - Special KeysKey Name Keypad Model(s) Function/Description<Alpha> 26-key Press <Alpha> to access lower case alpha characters and symbols on the 26-key keypad. Alpha-Numeric KeysAllIn Normal mode, use the alpha-numeric keys to enter numbers and letters. In Shift and CAPS modes, the alpha-numeric keys enter upper case let-ters.Backlight All <Backlight> toggles the Backlight on or off when you press it.<Fn>  All Press <Fn> to enter the FN input state. Use FN mode to access additional features and operations.<Power> AllPress Power to put the Falcon into sleep (suspend) mode if it is currently running, and wake up (resume) the Falcon if it was in sleep mode. Press and hold it briefly to turn off the Falcon.
Entering DataQuick Reference Guide  25System Tray Keyboard Indicators The System Tray Keyboard Indicators are located at the bottom of the display in the Task bar. The most recently activated state is in the left position if more than one state is active. •The   icon is displayed if either Shift or CAPS mode is active. • If more than two states are active at the same time, only the last two states are displayed in the System Tray. Scroll between icons to view the active modes.Table 5. Input States and their System Tray Indicators<Scan> 26-key52-key52-key NUPress <Scan> to activate the laser scanner. 4-Way Rocker Key26-key52-keyPress the edge of the 4-way rocker key to move the cursor or highlighted text entry during a menu/list selection. In a text window:• The <Up> arrow moves the cursor up one line.• The <Right> arrow moves the cursor to the right one character.• The <Down> arrow moves the cursor down one line.• The <Left> arrow moves the cursor to the left one character.<Ctrl>  48-key52-key NU<Ctrl> allows keyboard shortcuts like a PC. You can perform functions such as Save (Ctrl-s) and Find (Ctrl-f). Toggle on and off for text formatting (for example, Ctrl-b for bold, Ctrl-i for italics, Ctrl-u for underline).<Alt>48-key52-key52-key NUPress <Alt> to enter the Alt input state. Use Alt mode to access application menus.<Shift>48-key52-key52-key NUPress <Shift> to enter Shift input states. Use Shift mode to output upper-case characters and punctuation (identified over number keys).Key Name Keypad Model(s) Function/DescriptionIcon  State Keypad Model(s) FunctionNormal (Numeric) Mode26-key Present only on keypads with an Alpha key. It appears when Alpha or CAPS modes are not on.
Entering Data26 Falcon® 4400 Series with Windows® CEAlpha Mode 26-keyPress <Alpha> to enter lower case alpha characters and symbols. When in Alpha mode, the current alpha character is displayed by a system tray keyboard indica-tor. Alpha mode is persistent, which means that the system stays in Alpha mode until you press <Alpha> again. CAPS Mode26-keyPress <Fn> + <Alpha> to activate CAPS mode. CAPS mode generates upper case alpha characters A-Z.CAPS mode is persistent; press <Fn> + <Alpha> again to generate lower case characters. Punctuation keys are not affected. 48-key52-key52-key NUPress <Fn> + <SHIFT> to activate Caps mode. Caps mode generates upper case alpha characters A-Z.CAPS mode is normally persistent; you must press <Fn> + <SHIFT> again to generate lower case characters. Punctuation keys are not affected. If CAPS is active, and SHIFT is active, no icon is displayed.Fn Mode26-keyPress <Fn> to enter FN mode. <Fn> is independent of the <Alpha> key. Use FN mode to access the features and operations on the keypad.48-key52-key52-key NUFn mode converts alpha keys to punctuation and function keys. Fn mode is acti-vated by pressing <Fn>.Shift Mode48-key52-key52-key NUShift mode converts characters to upper-case letters or punctuation. Activated by pressing <Shift>. This state expires after a normal key is pressed unless the <Shift> key is held down. Toggles to make the next alpha character capitalized. If Shift state is active when the Caps State is active, no icon is displayed.Alt Mode48-key52-key52-key NUAlt mode converts keys to system keys that allow users to access the menu. Acti-vated by pressing <Alt>. This state expires after a normal key is pressed unless the <Alt> key is held down. Ctrl Mode 48-key52-key NU<Ctrl> allows keyboard shortcuts. You can perform functions such as Save (Ctrl-s) and Find (Ctrl-f). Toggle on and off for text formatting (for example, Ctrl-b for bold, Ctrl-i for italics, Ctrl-u for underline).Icon  State Keypad Model(s) Function
Entering DataQuick Reference Guide  2726-Key KeypadThe 26-key keypad is organized like a cell phone, with multi-tap access to alpha characters on numeric keys (see Figure 14). Use the ten (10) alpha-numeric keys and the <ESC> key to type letters, numbers, and symbols listed in Table 6 on page 28. Figure 14. 26-Key Keypad26-Key Functions. Most of the keys on the keypad of the Falcon have more than one function. To access the secondary features and functions, you must first press another key to access the desired input state. Only one system tray icon is visible at a time. The most recently activated state is in the left position of the system tray if more than one state is active. Alpha-Numeric Keys. Press the keys in Table 6 once, twice, or more times to cycle through the alpha letters and symbols until the desired character appears in the system tray. After the last letter or symbol in the sequence for that key, the next keypress will generate the first letter or symbol in the sequence. ScanAlpha (Caps)Enter Fn Tab. (Space)Esc BkSpBacklightPower
Entering Data28 Falcon® 4400 Series with Windows® CETable 6. 26-Key Keypad Alpha Characters and Symbols 48-Key KeypadThe 48-key keypad is designed to allow you to type all letters and numbers without requiring multiple key presses.Figure 15. 48-Key KeypadSome of the keys on the 48-key keypad of the Falcon have more than one function. To access the secondary features and functions, you must first press Normal Mode Alpha ModeKey First KeypressSecondKeypressThirdKeypressFourthKeypressFifth Keypress<ESC> : / @ : / <1> ,  \ *  ,  \ <2> A B  C A B <3> D  E  F  D  E <4> G H  I G H <5> J  K  L  J  K <6> M N  O M N <7> P  Q  R  S  P <8> T U  V T U <9> W  X  Y  Z  W Fn EscAltShift (Caps)Ctrl Backlight Power
Entering DataQuick Reference Guide  29another key to access the desired input state. See Table 4 on page 24 for fur-ther information.48-Key FunctionsPress the <Backlight> key to toggle the backlight on or off. To adjust the bright-ness press <FN><Backlight>. Press <Enter> to accept the changes.48-Key Input StatesThe input states for the 48-key keypad are <Caps>, <Shift>, <Ctrl>, <Alt>, and <Fn>. Each state is described in Table 5 on page 25.52-Key Keypad The standard 52-key keypad is designed to allow you to type all letters and numbers without requiring multiple key presses.Figure 16. 52-Key KeypadSome of the keys on the keypad of the Falcon have more than one function. To access the secondary features and functions, you must first press another key to access the desired input state. See Table 4 on page 24 for more information.AltFnPowerShift. (Backlight) Scan
Entering Data30 Falcon® 4400 Series with Windows® CE52-Key FunctionsPress <Fn>+< . > (period/decimal) to toggle the backlight on or off. To adjust the contrast, press <Fn>+<Alt> or select Start > Settings > Backlight. Press <Enter> to accept the changes. Accessing FN and ALT ModesThe input states for the 52-key keypad are <Caps>, <Shift>, <Alt>, and <Fn>. Each is described in Table 5 on page 25.52-Key Numbers Up (NU) KeypadThe full alphanumeric 52-Key Numbers Up (NU) keypad brings frequently used keys into a more ergonomic position, and is available with the 5250 TE overlay. Figure 17. 52-Key NU Keypad5250 KeymapThe 5250 keymap is designed to provide the keyboard functions needed to run 5250 terminal emulation software.The 5250 keymap is available with either the 48-key, 52-key, or 52-key NU model.AltFnPowerShiftBacklight ScanEscCtrl CapsSpace
Scanning Bar CodesQuick Reference Guide  31Figure 185250 Keymap for the 52-Key KeypadScanning Bar CodesLaser ScanningTo use the scanning function on units containing a laser scanning module, complete the following steps:1. Select and open a bar code application, such as Microsoft® WordPad.AltFnPowerShift. (Backlight) Scan
Scanning Bar Codes32 Falcon® 4400 Series with Windows® CEFigure 19. Scanning a Bar Code2. Aim the scan window at the bar code following the guidelines outlined in Figure 20.3. Press <Scan> on the keypad (26, 52 or 52-key NU) or the Scan Trigger on the handle. The laser scans as long as you hold the button or trigger, or for 10 seconds, or until a good scan is obtained.4. Aim the laser beam at the center of the bar code. • Position the unit close to bar code when scanning small bar codes. • Position it at a distance when scanning larger bar codes. • The laser is disabled after you release the key or after 10 seconds, or once a good scan is obtained.Figure 20. Laser Beam Positions Press <Scan> on the keypad (26, 52 or 52-key Correct Scanning PositionsIncorrect Scanning PositionsIdeal positioning A bit high, will read correctly A bit angled, will read correctlyPositioned too far to the right. Will not read entire bar code.Too angled;            cannot read the entire                          bar code.Bar code will not read. The  scanner should be posi-tioned perpendicular to the bar code bars.
Scanning Bar CodesQuick Reference Guide  335. The device beeps and the green LED indicator comes on until the trig-ger is released. The green LED and the beep tone indicate a good read. 6. The bar code data is entered in the current application. 7. Once a bar code is read successfully, the scanner turns off automatically. Refer to the section on Scanner Configuration in the PRG to modify the default settings. Bar Code Scanning with 2D ImagerScanning bar codes with the 2D imaging device is similar to scanning with a laser scanner. The operation and configuration of the scanner is performed in the same way as laser scanning devices. Trigger behavior and scanning time-outs are the same as laser scanning devices.Scanning DifferencesScanning Aimer The imager contains an aiming beam rather than a red laser. The aiming beam mimics a laser line for purposes of orienting the imager to a bar code. Figure 21 shows how the aiming beam visually differs from the laser beam in laser scanning devices.Figure 21. Laser vs. Imaging beamNote that the aiming beam for the imager is green, rather than red. If the bar code scan failed, adjust the reading angle or distance. Make sure thatthe laser beam scans across all bars of the bar code. Refer to Figure 20.Laser Aiming Beam
Image Capture34 Falcon® 4400 Series with Windows® CEOrientationRotational orientation does not affect the imager module's ability to read bar codes. For example, the imager can read a bar code when the aimer beam is parallel to the lines of the bar code. What is important is the location of the aimer in relation to the center of the bar code. The aiming beam should be centered over the bar code, but it can be positioned in any direction for a good read.Figure 22. Aiming Beam PositioningThe aiming beam is smaller when the imager is closer to the code and larger when it is farther away. Symbologies with smaller bars or elements (mil size) should be read closer to the unit. Symbologies with larger bars or elements (mil size) should be read farther from the unit. To scan a label, hold the imager at an appropriate distance from the target, pull the trigger, and center the aim-ing beam on the symbol. Scanning IlluminationAnother feature that can be enabled for 2D scanning is an array of illumina-tion LEDs. These LEDs provide illumination in dark environments and can improve scanning performance under certain lighting conditions. By default, the illumination LEDs are turned on. Illumination LEDs can be disabled using the PDT parameters. See the PRG for complete information on pro-gramming the LEDs.Image CaptureThe 2D imager can be used for capturing, manipulating, and transferring images. Linear bar codes 2D Matrix symbol
Flash MemoryQuick Reference Guide  35You can set options for image capture in the Imaging Control Panel. Various image formats can be selected, including TIFF, JPEG and BMP. You can also scale, rotate, and modify image quality settings. See the PRG for detailed infor-mation on using the Falcon 2D for image capture. Flash MemoryIn addition to the RAM-based storage standard on Windows CE terminals, the Falcon is also equipped with Datalight FlashFX Flash-based application and file storage area. Refer to the PRG for more information.Saving to FlashTo save an application or data to the Flash Memory, from your current appli-cation, select File > Save As > navigate to the FlashFX Disk location as described below.Flash FX LocationTo access the contents of Flash Memory:1. Double-tap the My Device icon on the desktop.2. Double-tap the FlashFX Disk icon to view the FlashFX Disk.The FlashFX storage memory persists across all reset (warm/cold reboot) condi-tions and software / firmware updates. Because of this, Datalogic very strongly recommends installing all applications,applets, programs, and important data files to the FlashFX disk of the Falcon.If an application or a data file is only installed or saved in RAM, a hard reset willresult in the loss of that application or data file.
Flash Memory36 Falcon® 4400 Series with Windows® CEFigure 23. Location of the FlashFX DiskFlashFX Disk SizeThe size of the FlashFX disk will vary, depending upon several factors, such as the size and number of currently running applications and the amount of memory currently consumed by the OS.To view the current size of Flash Memory:1. Double-tap the My Device icon on the desktop. (See Figure 23). Figure 24. Size of FlashFX DiskBA
Context Sensitive HelpQuick Reference Guide  372. Press and hold the FlashFX Disk directory with the stylus, and select Properties from the pop-up menu (see Figure 24A).3. The FlashFX Properties dialog opens (see Figure 24B). The number following Free is the amount of memory currently available on the Falcon.Table 7. FlashFX Disk SpecificationsContext Sensitive HelpMicrosoft Windows CE context sensitive help is available wherever a “?” but-ton appears in the upper right hand corner of the window. Press the “?” button to open the context help window.Figure 25. Using Windows CE Context Sensitive Help To open context sensitive Help, select/tap the “?” in the upper right corner of most screens. Select/tap the desired item from the list of hot links.FlashFX Disk SpecificationsTotal Flash size 64.0 MB 128 MBOS/Firmware uses up to 32.0 MB 32 MBFlashFX size 32.0 MB 96 MBFile storage size 31 MB (approximate) 90 MB (approximate)Running Application 22 MB (approximate) 81 MB (approximate)
Resetting the Falcon38 Falcon® 4400 Series with Windows® CEResetting the FalconThere are two reset methods for the Falcon. • A warm reset terminates a “hung” application, and clears the working RAM, but preserves the file system. • A cold reset forces all applications to close and clears working RAM and files not resident on the FlashFX Disk.Warm ResetA warm reset is a transition from the on or idle condition that closes all appli-cations, clears the working RAM, but preserves the file system. If an application “hangs,” initiate a warm reset to terminate the application.Procedure to Warm Reset The reset procedure varies, depending upon the keypad on your Falcon. The first two keys of the sequence can be pressed in any order, but the unit will not reset until they both are held down and then the third key (<Bksp>, <F1> or <Del>) is pressed. All three keys must be held down for the unit to reset. Refer to Figure 26 on page 39 for the location of the reset keys.26-Key Falcon. Press and hold: <FN>+<Alpha>+<Bksp>.48-Key Falcon. Press and hold: <Ctrl>+<Alt>+<Bksp>.52-Key Falcon. Press and hold: <Alt>+<FN>+<F1>.52-Key NU Falcon. Press and hold: <Ctrl>+<Alt>+<Del>.CAUTIONDatalogic recommends that you always attempt a warm reset before initiating acold reset. Once you initiate a cold reset, all applications are forcibly closed andworking RAM and files are cleared. It is a good idea to store important data in FlashFX storage for this reason. Referto Flash Memory on page 35 for more information on Flash Memory.DO NOT use a sharp object on the reset button. Sharp objects can puncture thekeypad, disabling the reset function, rupturing the Falcon’s industrial seal, andvoiding your warranty.
Resetting the FalconQuick Reference Guide  39Figure 26. Warm Reset After Warm Reset• The splash screen will appear briefly.• The desktop appears with the application shortcuts on the screen.• RF Network PC Card (if present) connects to the network system.Cold ResetA cold reset is a complete reset of the Falcon in which all applications are forc-ibly closed and working RAM is cleared. 1326547890F1 F2 F3 F4 F5ScanEsc BkSp.EnterTa bFnAlphaS h iftTa b CapsStartHom eSpaceG H IP Q R S W  X Y ZT U VJ K  LA B C:  / @,  \ *D E FM N O26-Key 52-Key / 5250 48-Key 123113223Hold down 1 & 2 ...then press 3CapsBkSpBkSpDelShiftCtrlFnSpcAltEsc1ABCDEFGHIJKLMNOPQRSTUVWZXY2345677 80.9TabTabEnterEnterScan12352-Key NUThe custom settings in the registry are persistent.
Resetting the Falcon40 Falcon® 4400 Series with Windows® CEReason to Cold Reset. Press the <Reset> button when the Windows CE operating system locks up and the warm reset command does not work.Procedure to Cold Reset. To perform a cold reset, insert a paper clip into the cold <Reset> button while pressing the <Power> button (refer to Figure 27).Figure 27. Cold Reset After Cold ResetWhen a Falcon goes through the cold reset sequence, it clears the working RAM and initializes the file system. You will lose any applications and data which are not stored in persistent flash memory (refer to Flash Memory start-ing on page 35).CAUTIONDatalogic recommends that you always attempt a warm reset before initiating acold reset. Once you initiate a cold reset, all applications are forcibly closed andworking RAM and files are cleared. Any applications, files, or data in RAM will be lost if you cold reset. Only the appli-cations and the files in the FlashFX Disk are preserved upon a cold reset. Refer toFlash Memory on page 35 for more information on preserving applications andfiles with the persistent FlashFX storage memory. Do not use a sharp object on the cold reset button as this can puncture the key-pad, disabling the reset function, rupturing the Falcon industrial seal, and voidingyour warranty. Datalogic recommends using a straightened paper clip.1326547890ScanEsc BkSp.EnterTabFnAlphaShiftTab CapsStartHomeSpaceG H IP Q R S W X Y ZT U VJ K LA B C:  / @,  \ * D E FM N OCold ResetButton Access
Maintaining the FalconQuick Reference Guide  41• The splash screen will appear after a short period.• Recalibrate the touch screen or press <ESC> to circumvent calibration.• The desktop appears with the application shortcuts on the screen.• RF Network PC Card (if present) connects to the network system.Maintaining the FalconWith normal use, the Falcon, Dock, Four-Slot Dock and battery chargers require no maintenance. For trouble-free service, observe the following tips when using the Falcon:• To prolong its life and avoid problems, keep the Falcon clean. Use a clean, soft cloth dampened with a mild, dilute cleanser. • If you need to clean the display, clean it with a lens cloth or other soft cloth dampened with a mild, dilute cleaning solution.TroubleshootingRefer to the Falcon 4400 Windows CE PRG for more information.The custom settings in the registry are persistent.CAUTIONNever use a pen, pencil, or other sharp object on the display/touch screen.Use only the supplied stylus or plastic-tipped pens intended for use with atouch-sensitive screen.Do not immerse the Falcon, docks, or battery chargers in liquid.Do not use abrasive paper/cloth or abrasive/corrosive cleaners to clean theunit.WARNINGDo not use a sharp object to Reset; use a paper clip. A sharp object canpuncture the keypad, disabling the reset function, rupturing the industrialseal, and voiding your warranty. Refer to the Falcon 4400 Quick ReferenceGuide for reset instructions.
Troubleshooting42 Falcon® 4400 Series with Windows® CETable 8. Troubleshooting Problems, Causes, and SolutionsProblem Possible Cause SolutionThe Falcon does not turn on.The battery pack is not installed properly.Ensure the battery is installed properly.System failure.  Perform a cold reset. Refer to Resetting the Falcon starting on page 38.During boot, the terminal beeps twice and the system stays blank.Firmware flash memory has been corrupted.Re-download the firmware using the FUU in bootload mode. Refer to the PRG.Rechargeable battery pack did not charge.Battery failure. Replace the battery. If the Falcon terminal still does not operate, try a warm reset then a cold reset; refer to Resetting the Falcon starting on page 38.The Falcon was removed from the dock while battery was charging. Insert the Falcon in dock and begin charging. The bat-tery pack and backup battery require 4 hours to fully charge.Characters are not visible on the display.The Falcon is not powered on. Press <PWR>.The ambient room light is too dark or low.Turn on the backlight. Refer to the PRG.No sound is audible. Volume setting is low or turned off.Adjust the sound by going to Start > Settings > Con-trol Panel > Volume & SoundsORScan a bar code from the PRG.The Falcon turns itself off. The Falcon is inactive. The Falcon turns off after a period of inactivity. You can set duration from one to 30 minutes. Refer to the PRG to modify the default settings.During data communication, no data was transmitted, or transmitted data was incomplete.The Falcon was removed from the dock or unplugged from host PC during communications.Replace the terminal in the dock, or replace the serial cable, and retransmit.Incorrect cable configuration. See your System Administrator.Communication software was incorrectly installed or config-ured.Perform setup as described in the PRG.
TroubleshootingQuick Reference Guide  43The Falcon does not accept scan input.The scanning window is dirty. Carefully wipe the scanning window with a soft, clean cloth. Do not use abrasive cleaners.The scanning application is not loaded. Verify that the unit is loaded with a scanning applica-tion. See your System Administrator.Unreadable bar code. Be sure the symbol is not defaced.Distance between exit window and bar code is incorrect.Be sure you are within proper scanning range.The Falcon is not programmed for that symbology.Be sure the terminal is programmed to accept the type of bar code you are scanning. Try using FF3A to turn on maximum defaults, as described in “Programming Parameters” in the Falcon 4400 PRG.The Falcon is not programmed to generate a beep.If you are expecting a beep on a good decode and don’t hear one, check that the application is set to gen-erate a beep on good decode.Battery is low.  If the scanner stops emitting a laser beam when you press the trigger, check your battery level. Refer to the PRG.Note: If the scanner is still not reading sym-bols, contact your distributor or Datalogic.The UPC/EAN extension (supplemental label) is not always scanned.Laser beam only crosses over base of UPC/EAN label.Set the Read Verification for extensions (parameter 0528) to a value lower than the Read Verification for the base label. See the PRG.Problem Possible Cause Solution
Troubleshooting44 Falcon® 4400 Series with Windows® CEThe Spare Battery LED on the dock is flashing RED.Time-out fault: the spare bat-tery pack charging has exceeded the maximum time-out period.In either case, if the Spare Battery LED is flashing red, do the following:1. Disconnect the AC adapter from the dock.2. Remove the spare battery pack and the Falcon from the dock.3. Connect the AC adapter to the dock.4. If the Spare Battery LED is flashing red, there is a problem with the dock. Disconnect the AC adapter from the dock and contact a service technician.5. If the Spare Battery LED is off, insert a different spare battery pack in the dock.6. If, in the course of charging the spare battery, the Spare Battery LED is flashing red, there is a problem with the dock. Disconnect the AC adapter from the dock and contact a service technician.7. Otherwise, there is a problem with the first spare battery pack. Discontinue use of the first spare bat-tery pack. Refer to the PRG for instructions on bat-tery disposal.Over-voltage fault: the spare battery pack charging has exceeded the maximum charge voltage of the battery.Problem Possible Cause Solution
TroubleshootingQuick Reference Guide  45RF Connectivity Troubleshooting  Does the terminal respond to a PING command from a PC? NODoes the terminalasso ciate wit h  the AP  ?  YESdispl a y an error du ring the  boot pro c e ss?  Gather fac t s :   •   Terminal type  •   AP & RF card  brand  (en s u r e latest version of firmwa re installe d)  •   Hos t  type   •   Software type    •   Software version (en s u r e la test versi on is installed)  •   Freq uen cy an d duratio n of issue   Can you pi ng  the   host from a P C  on same  sub net  ?  Can you pi ng  the  terminal from the AP  ?   Potential Problems :  •  S e cu rit y  I ssu e – Che c k  SSID, WEP,  LEAP s e ttings   •  Ran ge Issue   Potential Problems :  •  IP Address Issue  •  Check security settings Potential Problems :  •  Ho st unavaila ble              Potential Problems :  •  IP addre ss i s sue (dupli c at e address on terminal ). Turn  off the terminal and attempt PING again  •  Run t r a c ert  comman d  to determin e  loca tion of brea kd own of connectivity.   RF conne ctivity  obtaine d. See your  s o ftware manual for  further info rm ation or  c ontac t Datalogic Mobiletechnical support.       Does the terminal connect to the host              ?Does the terminalSTART NONONOYES YES YES YES YES NONO   :      Potential Problems Ping terminal from host or  use tracert to  determi ne the location  of the breakdown in  communication.   (For more information on the Ping command, go to the command prompt on the PC and type PING. For more information on the trace route command, go to the command prompt on the PC and type tracert.) Contact Tech Support.
Technical Support46 Falcon® 4400 Series with Windows® CETechnical SupportDatalogic Mobile Website SupportThe Datalogic Mobile website (www.mobile.datalogic.com) is the complete source for technical support and information for Datalogic products. The site offers the Datalogic TekForum, product support, product registration, war-ranty information, product manuals, product tech notes, software updates, demos, and instructions for returning products for repair. Datalogic Mobile Website TekForumSearch for information on the TekForum on the Datalogic home page. Browse the TekForum to find answers to your questions about common technical issues.Reseller Technical SupportAn excellent source for technical assistance and information is an authorized Datalogic reseller. A reseller is acquainted with specific types of businesses, application software, and computer systems and can provide individualized assistance. Telephone Technical SupportIf you do not have internet or email access, you may contact Datalogic techni-cal support at (541) 743-4802.
Quick Reference Guide  47Appendix A: Datalogic MobileFalcon® Windows® CE SeriesEnd User License AgreementNotice to End User: The Datalogic Product you have acquired contains Software, which is integral to the product’s operation.This Software is being provided to you under license, subject to the terms and conditions of this Agreement. If you use the Data-logic Product, you will be deemed to have accepted the terms and conditions of this Agreement. If you do not intend to be boundto the terms of this Agreement, Datalogic is not willing to license the Software to you, you may not use the Datalogic Product orthe Software, and you must contact the party from whom you acquired the Datalogic Product for instructions.This End User Software License Agreement (“Agreement”) is a legally binding agreement governing the licensing of the Soft-ware and Documentation by Datalogic Mobile, Inc. and its wholly owned subsidiaries and affiliates (“Datalogic”) to the entity orperson who has purchased or otherwise acquired a Datalogic Product (“End User”). For purposes of this Agreement, any soft-ware that is associated with a separate end-user license agreement is licensed to you under the terms of that license agreement.Datalogic and End User hereby agree as follows: 1. Definitions.1.1 “Documentation” means materials such as user’s guides, program reference guides, quick reference guides, manuals, orsimilar materials associated with or related to the Datalogic Product, whether in printed, “online”, or other form. 1.2 “Proprietary Information” means: (a) source code, object code, software, documentation, and any related internal design,system design, data base design, algorithms, technology, technical data or information, implementation techniques, and tradesecrets related to the Software, (b) any other trade secrets marked appropriately or identified as proprietary or confidential, and(c) any information that End User, under the circumstances, should recognize as confidential. Proprietary Information does notinclude any information that the receiving party can establish was (1) in the public domain, (2) already in the receiving party’spossession or rightfully known prior to receipt, (3) rightfully learned from a third party not in violation of any other's proprietaryrights, or (4) independently developed without access to Proprietary Information.1.3 “Datalogic Product” means Datalogic Mobile’s Falcon® Windows® CE .NET Series, including all preloaded Software in orprovided in connection with the Datalogic Product and all Documentation related to such product, which has been purchased orotherwise acquired by End User, whether obtained directly or indirectly from Datalogic.1.4 “Software” means any software or computer programs of Datalogic or its third party licensors in machine readable form whichis either preloaded in or provided in connection with the Datalogic Product, whether obtained directly or indirectly from Datalogic,including any related update or upgrade such as enhancements or modifications.2. Scope Of License Granted.2.1 Datalogic grants to End User a non-exclusive, non-transferable, perpetual license to use the Software, solely on a DatalogicProduct, in machine-readable form only, solely for End User's internal business purposes. This Agreement does not convey own-ership of the Software to End User. Title to the Software shall be and remain with Datalogic or the third party from whom Data-logic has obtained a licensed right. As used in this Agreement, the term “purchase” or its equivalents when applied to theSoftware shall mean “acquire under license.” 2.2 End User shall not copy, modify, decompile, disassemble, reverse engineer, or otherwise reproduce or remanufacture theSoftware, whether modified or unmodified, nor sell, assign, sublicense, distribute, lend, rent, give, or otherwise transfer the Soft-ware to any other person or organization, for purposes other than as expressly provided in this Agreement, or to the extent spe-cifically allowed under foreign law solely for the purposes of interoperability, without Datalogic’s prior written consent.3. Transfers, Support.3.1 Any copying, installing, reproduction, remanufacture, reverse engineering, electronic transfer, or other use of the Software onother than a Datalogic Product will be a material breach of this Agreement. 3.2 End User shall not sell, assign, sublicense, distribute, lend, rent, give, or otherwise transfer a Datalogic Product containingSoftware to any third party unless such third party agrees with Datalogic in writing to be bound by the terms and conditions ofthis Agreement. Any such transfer of a Datalogic Product absent such agreement shall be null and void.
Appendix A: Datalogic Mobile Falcon® Windows® CE Series End User License Agreement48Falcon® 4400 Series with Windows® CE3.3 End User may obtain support for Software from Datalogic at Datalogic’s standard support fees and under Datalogic’s stan-dard support terms and conditions in effect at the time the support is requested.4. Intellectual Property.End User acknowledges that the Software constitutes valuable trade secrets of Datalogic or Datalogic’s third party licensors andthat the Software is protected by intellectual property laws and treaties. The license set forth in this Agreement does not transferto End User any ownership of Datalogic’s or its third party licensors' copyrights, patents, trademarks, service marks, tradesecrets, or other intellectual property rights and End User shall have no right to commence any legal actions to obtain suchrights. End User shall not remove, modify, or take any other action that would obscure any copyright, trademark, patent marking,or other intellectual property notices contained in or on the Datalogic Product.5. Proprietary Information.5.1 End User acknowledges that Proprietary Information is the confidential, proprietary, and trade secret property of Datalogicand Datalogic’s third party licensors and End User acquires no right or interest in any Proprietary Information.5.2 End User shall not disclose, provide, or otherwise make available the Proprietary Information of Datalogic or its third partylicensors to any person other than End User’s authorized employees or agents who are under confidentiality agreement, andEnd User shall not use the Proprietary Information other than in conjunction with use of the Datalogic Product exclusively for EndUser’s internal business purposes. End User shall take steps to protect the Proprietary Information no less securely than if itwere End User's own intellectual property. 5.3 The provisions of this Proprietary Information Section shall survive and continue for five (5) years after the termination of thisAgreement. 6. Limited Warranty.6.1 Datalogic warrants that, under normal use and operation, the Datalogic Product will conform substantially to the applicableDocumentation for the period specified in the Documentation. During this period, for all reproducible nonconformities for whichDatalogic has been given written notice, Datalogic will use commercially reasonable efforts to remedy nonconformities verifiedby Datalogic. End User agrees to supply Datalogic with all reasonably requested information and assistance necessary to helpDatalogic in remedying such nonconformities. For all defects reported to Datalogic within the warranty period, Datalogic’s liabilityis limited to providing End User with one copy of corrections or responding to End User's problem reports according to Data-logic's standard assistance practices. Datalogic does not warrant that the product will meet End User's requirements or that useof the product will be uninterrupted or error free, or that Datalogic's remedial efforts will correct any nonconformance. This limitedwarranty does not cover any product that has been subjected to damage or abuse, whether intentionally, accidentally, or byneglect, or to unauthorized repair or unauthorized installation, and shall be void if End User modifies the product, uses the prod-uct in any manner other than as established in the Documentation, or if End User breaches any of the provisions of this Agree-ment.6.2 EXCEPT AS PROVIDED IN THIS AGREEMENT, THE DATALOGIC PRODUCT IS PROVIDED “AS IS” AND DATALOGICMAKES NO WARRANTIES OF ANY KIND, EXPRESS OR IMPLIED, WRITTEN OR ORAL, WITH RESPECT TO THE PROD-UCT, AND SPECIFICALLY DISCLAIMS THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTIC-ULAR PURPOSE. 7. Infringement.7.1 Datalogic will defend End User against any claim in a lawsuit that the Datalogic Product furnished hereunder infringes aUnited States patent or copyright of a third party and Datalogic will pay any damages finally awarded against End User by a courtof competent jurisdiction that are attributable to such claim or will pay End User’s part of any settlement that is attributable tosuch claim, provided, that 1) End User notifies Datalogic promptly in writing of the claim, 2) Datalogic controls the defense or set-tlement of the claim, and 3) End User cooperates fully with Datalogic in such defense or settlement. All notices of a claim shouldbe sent to Datalogic Mobile, Inc., 1505 Westec Drive, Eugene, OR 97402.7.2 In the defense or settlement of any such claim, Datalogic may, at its option, 1) procure for End User the right to continueusing the Datalogic Product, 2) modify the Datalogic Product so that it becomes non-infringing, 3) replace the Datalogic Productwith an equivalent product not subject to such claim, or 4) provide End User an opportunity to return the Datalogic Product andreceive a refund of the purchase price paid, less a reasonable allowance for use.7.3 Datalogic shall have no liability to End User for claims of infringement based upon 1) the use of any Datalogic Product incombination with any product which Datalogic has not either furnished or authorized for use with such Datalogic Product 2) theuse of any Datalogic Product designed, manufactured, or modified to the specifications of End User, or 3) End User’s modifica-tion of the Datalogic Product without written authorization from Datalogic.
Appendix A: Datalogic Mobile Falcon® Windows® CE Series End User License AgreementQuick Reference Guide  497.4 THE FOREGOING STATES DATALOGIC’S COMPLETE AND ENTIRE OBLIGATION CONCERNING CLAIMS OF PATENT,COPYRIGHT, OR OTHER INTELLECTUAL PROPERTY INFRINGEMENT, CANCELS AND SUPERCEDES ANY PRIORAGREEMENTS, WHETHER ORAL OR WRITTEN, BETWEEN THE PARTIES CONCERNING SUCH CLAIMS, AND WILL NOTBE MODIFIED OR AMENDED BY ANY PAST, CONTEMPORANEOUS, OR FUTURE AGREEMENTS OR DEALINGSBETWEEN THE PARTIES, WHETHER ORAL OR WRITTEN, EXCEPT AS SET FORTH IN A FUTURE WRITING SIGNED BYBOTH PARTIES.8. Limitation Of Liability.EXCEPT AS PROVIDED IN SECTION 7, DATALOGIC SHALL NOT BE LIABLE FOR ANY CLAIMS AGAINST END USER BYANY OTHER PARTY. IN NO EVENT SHALL DATALOGIC'S LIABILITY FOR DAMAGES, IF ANY, WHETHER BASED UPONCONTRACT, TORT (INCLUDING NEGLIGENCE), PRODUCT LIABILITY, STRICT LIABILITY, WARRANTY, OR ANY OTHERBASIS, EXCEED THE PRICE OR FEE PAID BY END USER FOR THE DATALOGIC PRODUCT. UNDER NO CIRCUM-STANCES SHALL DATALOGIC BE LIABLE TO END USER OR ANY THIRD PARTY FOR LOST PROFITS, LOST DATA, INTER-RUPTION OF BUSINESS OR SERVICE, OR FOR ANY OTHER SPECIAL, CONSEQUENTIAL, CONTINGENT, INDIRECT,INCIDENTAL, PUNITIVE, EXEMPLARY, OR OTHER SIMILAR DAMAGES, EVEN IF DATALOGIC HAS BEEN ADVISED OFTHE POSSIBILITY OF SUCH DAMAGES.9. Government Restricted Rights; International Use.9.1 Use, duplication, or disclosure of the Software by the U.S. Government is subject to the restrictions for computer softwaredeveloped at private expense as set forth in the U.S. Federal Acquisition Regulations at FAR 52.227-14(g), or 52.227-19 or in theRights in Technical Data and Computer Software clause at DFARS 252.227-7013(c)(1)(ii), whichever is applicable. 9.2 If End User is using the Datalogic Product outside of the United States, End User must comply with the applicable local lawsof the country in which the Datalogic Product is used, with U.S. export control laws, and with the English language version of thisAgreement. The provisions of the “United Nations Convention on International Sale of Goods” shall not apply to this Agreement.10. Termination.10.1 Either party may terminate this Agreement or any license granted under this Agreement at any time upon written notice ifthe other party breaches any provision of this Agreement.10.2 Upon termination of this Agreement, End User immediately shall cease using any non-preloaded software and shall returnto Datalogic or destroy all non-preloaded software covered by this Agreement, and shall furnish Datalogic with a certificate ofcompliance with this provision signed by an officer or authorized representative of End User. For preloaded software, End Useragrees to sign a waiver prepared by Datalogic concerning further use of the preloaded Software. End User’s resumed or contin-ued use of the preloaded Software after termination shall constitute End User’s agreement to be bound by the terms and condi-tions of this Agreement for such use. 11. General Provisions.11.1 Entire Agreement; Amendment. This document contains the entire agreement between the parties relating to the licensingof the Software and supersedes all prior or contemporaneous agreements, written or oral, between the parties concerning thelicensing of the Software. This Agreement may not be changed, amended, or modified except by written document signed byDatalogic. 11.2 Notice. All notices required or authorized under this Agreement shall be given in writing, and shall be effective whenreceived, with evidence of receipt. Notices to Datalogic shall be sent to the attention of the Legal Department, General Counsel,Datalogic Mobile, Inc., 1505 Westec Drive, Eugene, OR 97402, or such other address as may be specified by Datalogic in writ-ing. 11.3 Waiver. A party’s failure to enforce any of the terms and conditions of this Agreement shall not prevent the party’s laterenforcement of such terms and conditions. 11.4 Governing Law; Venue: This Agreement and the rights of the parties hereunder shall be governed by and construed inaccordance with the laws of the State of Oregon U.S.A, without regard to the rules governing conflicts of law. The state or federalcourts of the State of Oregon located in either Multnomah or Lane counties shall have exclusive jurisdiction over all mattersregarding this Agreement, except that Datalogic shall have the right, at its absolute discretion, to initiate proceedings in thecourts of any other state, country, or territory in which End User resides, or in which any of End User's assets are located.11.5 Attorneys’ Fees. In the event an action is brought to enforce the terms and conditions of this Agreement, the prevailing partyshall be entitled to reasonable attorneys’ fees, both at trial and on appeal. - END -
50Falcon® 4400 Series with Windows® CEAppendix  B: Microsoft® Windows® CEEnd User License AgreementDatalogic is contractually obligated by Microsoft® to include the following information as part of our software end user licenseagreement:You have acquired a device (“DEVICE”) that includes software licensed by Datalogic from Microsoft Licensing Inc. or its affiliates(“MS”). Those installed software products of MS origin, as well as associated media, printed materials, and “'online” or electronicdocumentation (“SOFTWARE”) are protected by international intellectual property, laws and treaties. The SOFTW.ARE islicensed, not sold. All rights reserved.IF YOU DO NOT AGREE TO THIS END USER LICENSE AGREEMENT (“EULA”), DO NOT USE THE DEVICE OR COPY THESOFTWARE, INSTEAD, PROMPTLY CONTACT DATALOGIC FOR INSTRUCTIONS ON RETURN OF THE UNUSEDDEVICE(S) FOR A REFUND. ANY USE OF THE SOFTWARE, INCLUDIING BUT NOT LIMITED TO USE ON THE DEVICE,WILL CONSTITUTE YOUR AGREEMENT TO THIS EULA (OR RATIFICATION OF ANY PREVIOUS CONSENT).GRANT OF SOFTWARE LICENSE, This EULA grants you the following license:• You may use the SOFTWARE only on the DEVICE.• NOT FAULT TOLERANT. THE SOFTWARE IS NOT FAULT TOLERANT. DATALOGIC HAS INDEPENDENTLY DETER-MINED HOW TO USE THE SOFTWARE IN THE DEVICE, AND MS HAS RELIED UPON DATALOGIC TO CONDUCT SUFFICIENT TESTING TO DETERMINE THAT THE SOFTWARE IS SUITABLE FOR SUCH USE. • NO WARRANTIES FOR THE SOFTWARE. THE SOFTWARE is provided “AS IS” and with all faults. THE ENTIRE RISK AS TO SATISFACTORY QUALITY, PERFORMANCE, ACCURACY, AND EFFORT (INCLUDING LACK OF NEGLI-GENCE) IS WITH YOU. ALSO, THERE IS NO WARRANTY AGAINST INTERFERENCE WITH YOUR ENJOYMENT OF THE SOFTWARE OR AGAINST INFRINGEMENT, IF YOU HAVE RECEIVED ANY WARRANTIES REGARDING THE DEVICE OR THE SOFTWARE, THOSE WARRANTIES DO NOT ORIGINATE FROM, AND ARE NOT BINDING ON, MS.• Note on Java Support. The SOFTWARE may contain support for programs written in Java. Java technology is not fault tolerant and is not designed, manufactured, or intended for use or resale as online control equipment in hazardous envi-ronments requiring fail-safe performance, such as in the operation of nuclear facilities, aircraft navigation or communica-tion systems, air traffic control, direct life support machines, or weapons systems, in which the failure of Java technology could lead directly to death, personal injury, or severe physical or environmental damage. Sun Microsystems, Inc. has contractually obligated MS to make this disclaimer.• No Liability for Certain Damages. EXCEPT AS PROHIBITED BY LAW, MS SHALL HAVE NO LIABILITY FOR ANY INDI-RECT, SPECIAL, CONSEQUENTIAL OR INCIDENTAL DAMAGES ARISING FROM OR IN CONNECTION WITH THE USE OR PERFORMANCE OF THE SOFTWARE. THIS LIMITATION SHALL APPLY EVEN IF ANY REMEDY FAILS OF ITS ESSENTIAL PURPOSE. IN NO EVENT SHALL MS BE LIABLE FOR ANY AMOUNT IN EXCESS OF U.S. TWO HUNDRED FIFTY DOLLARS (U.S. $250.00).• Limitations on Reverse Engineering, Decompilation, and Disassembly, You may not reverse engineer, decompile, or dis-assemble the SOFTWARE, except and only to the extent that such activity is expressly permitted by applicable law not-withstanding this limitation.• SOFTWARE TRANSFER ALLOWED BUT WITH RESTRICTIONS. You may permanently transfer rights under this EULA only as part of a permanent sale or transfer of the Device, and only if the recipient agrees to this EULA. If the SOFTWARE is an upgrade, any transfer must also include all prior versions of the SOFTWARE.• EXPORT RESTRICTIONS, You acknowledge that SOFTWARE is of US-origin. You agree to comply with all applicable international and national laws that apply to the SOFTWARE, including the U.S. Export Administration Regulations, as well as end-user, end-use and country destination restrictions issued by U.S. and other governments. For additional information on exporting the SOFTWARE, see http://www.microsoft.com/exporting/.
Quick Reference Guide  51Appendix C: Datalogic Mobile Falcon®Windows® CE Product Series WarrantyWarrantyFalcon products are guaranteed against defects in materials and workmanship for the period specified at the time of sale. Thiswarranty shall apply to Falcon Portable Data Terminals (PDT's), Base Stations for the Falcon and Chargers for the Falcon.Cables, mounts and other accessory items are specifically warranted for a period of 90-days from product purchase. Customermust notify Datalogic of the claimed defect before the expiration of the Warranty period and obtain from Datalogic a return autho-rization number for return of the product to designated Datalogic service center. If Datalogic determines Customer’s claim isvalid, Datalogic will repair or replace product without additional charge for parts and labor. Customer shall be responsible forpackaging and shipping the product to the designated Datalogic service center, with shipping charges prepaid. Datalogic shallpay for the return of the product to Customer if the shipment is to a location within the country in which the Datalogic service cen-ter is located. Customer shall be responsible for paying all shipping charges, duties, taxes, and any other charges for productsreturned to any other locations.Warranty is subject to the limitations and exclusions set forth in the paragraphs that follow.WARRANTY SET FORTH ABOVE IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING MER-CHANTABILITY AND FITNESS.ExclusionsWarranty coverage shall not apply to any claimed defect, failure or damage which Datalogic determines was caused by: abuse,neglect, improper use of product; failure to provide product maintenance, including but not limited to cleaning of the display inaccordance with product reference guide; installation or service of product by other than Datalogic representatives; use of prod-uct with any other instrument, equipment or apparatus; modification or alteration of product or units with Warranty Void labelsthat have been tampered with. External cables and replacement of upper window/cartridge due to scratching, stains or otherdegradation will not be covered under the Warranty. External power supplies returned for service must be accompanied by theoriginal product for performance of service.Returned products that Datalogic has determined are not covered by Warranty, will be charged Datalogic standard repair ratesthen in effect for repair of product. Replacement of display due to scratching, stains or other degradation will not be coveredunder Warranty. If a product is determined to be not repairable customer will be notified and product may be returned to cus-tomer at their request. A minimum repair fee may be charged.Limitation of LiabilityDATALOGIC's REPAIR OR REPLACEMENT OF DEFECTIVE PRODUCT AS SET FORTH ABOVE IS THE CUSTOMER’SSOLE AND EXCLUSIVE REMEDY ON ACCOUNT OF CLAIMS OF BREACH OF WARRANTY OR PRODUCT DEFECT.UNDER NO CIRCUMSTANCES WILL DATALOGIC BE LIABLE TO CUSTOMER OR ANY THIRD PARTY FOR ANY LOSTPROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL IN-DIRECT, SPECIAL OR CONTINGENT DAMAGES REGARDLESS OFWHETHER DATALOGIC HAD ADVANCE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES.AssignmentCustomer may not assign or otherwise transfer its rights or obligations under Warranty except to a purchaser or transferee ofproduct. No attempted assignment or transfer in violation of this provision shall be valid or binding upon Datalogic.Risk of LossCustomer shall bear risk of loss or damage for product in transit to Datalogic. Datalogic shall assume risk of loss or damage forproduct in Datalogic's possession or product being returned to Customer by Datalogic, except such loss or damage as may becaused by the negligence of Customer, its agents or employees. In the absence of specific written instructions for the return ofproduct to Customer, Datalogic will select the carrier, but Datalogic shall not thereby assume any liability in connection with thereturn shipment.
52Falcon® 4400 Series with Windows® CEAppendix  D: Safety InformationLaser Safety LabelFigure 28. Laser Safety Label Advisory StatementRegulatory StatementsRadio Frequency InterferenceThis equipment has been tested and found to comply with the limits of a Class A digital device, pursuant to Part 15 of the FCCRules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operatedin a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed andused in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of thisequipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the inter-ference at his or her own expense.In addition, operation of this equipment is subject to the following two conditions:(1) This device may not cause harmful interference, and(2) This device must accept any interference received, including interference that may cause undesired operation.Canadian Compliance StatementThis Class A Digital apparatus complies with Canadian ICES-003.Cet appareil numérique de la Classe A est confirme à la norme NMB-003 du Canada.CAUTIONUse of controls, adjustments, or performance of procedures other than those specified hereinmay result in hazardous visible or invisible laser light exposure.This figure illustrates an example of a laser safety label, which islocated on the scanning pod of laser-based Falcon 4400 seriesunits. The label on your unit may appear different or have differentinformation. Please refer to your unit for specific laser safety requirements.The Advanced Long Range Laser is rated Class 3R per EN60825-1 andClass II per CFR 1040.Models with the Linear Imager are rated LED Class 1 per IEC 60 825-1:2001,only.PAT: 4,387,297 - 4,593,186 - 4,460,120 - 4,758,717 - 5,130,520 CAN: 24611032079AN263NRTLSafetytestedProductionmonitoredPRODUCT SERVICESERIAL # FLYYDDDXXXPRODUCT OF USADatalogic Mobile1505 Westec Dr.Eugene, OR  97402Item # 345-4201-005EUR: CE0560RADIO: BREEZECOMFCC: M52PCRNZZ-00DATE OF MANUFAVOID EXPOSURE — LASER LIGHT IS EMITTED FROM THIS APERTURE  Complies with 21CFR and Part 15 of FCC rules.BACKUP BATTERY: 3.1 V LithiumApproved RLAN Module insideCAUTIONChanges or modifications not expressly approved by the party responsible for FCC compliancecould void the user's authority to operate this equipment.For information about the disposal of Waste Electrical and Electronic Equipment (WEEE),please refer to the Datalogic Mobile website at www.mobile.datalogic.com.
Quick Reference Guide  53Appendix  E: Laser SafetyInternational Caution Statements for CLASS11, 22, 3R3, II4, and IIA5 Laser DevicesEnglishDatalogic scanners are certified in the U.S. to conform to the requirements of DHHS/CDRH 21CFR Subchapter J and to the requirements of IEC/EN 60825-1:1998-2001.Class 1, 2, 3R, Class II, and IIA products are not considered to be hazardous. The scanner contains internally a Vis-ible Laser Diode (VLD) whose emissions do not exceed the maximum limits as set forth in the above regulations. The scanner is designed so that there is no human access to harmful laser light during normal operation, user main-tenance or during prescribed service operations.CAUTION If the scan pattern is a single dot when depressing the trigger, discontinue operation and return the scanner to Dat-alogic.CAUTIONDo not attempt to open or otherwise service any components in the optics cavity. Opening or servicing any part of the optics cavity by unauthorized personnel may violate laser safety regulations. The optics system is a factory only repair item.CAUTIONUse of optical systems with the scanner will increase eye hazard. Optical instruments include binoculars, micro-scopes and magnifying glasses. This does not include eye glasses worn by the user.FrenchCe scanneurs du Datalogic sont certifié conforme à la norme DHHS/CDRH 21CFR sous-chapitre J et à la norme IEC/EN 60825-1:1998-2001.Les produits de class 1, 2, 3R, class II, et de IIA ne sont pas considérés dangereux. Le scanneur contient une diode laser visible (VLD) dont les émissions ne dépassent pas les limites prescrites dans les normes précitées. Le scanneur est conçu de façon à ce qu’il ne soit pas possible d’accéder à la lumière laser pendant l’utilisation normale, l’entretien par l’utilisateur et les fonctions de maintenance prescrites.ATTENTIONSi, quand la fonction de balayage est lancée, le diagramme de balayage est constitué d’un seul point, cesser d’utiliser le scanneur et le retourner à Datalogic.ATTENTIONNe pas essayer d’ouvrir ou de réparer les composants de la cavité optique. L’ouverture de la cavité optique ou la rép-aration de ses composants par une personne non qualifiée peut entraîner le non-respect des règles de sécurité rela-tives au laser. Le système optique ne peut être réparé qu’en usine.1. Class 1 applies to IEC/EN STD (Europe).2. Class 2 applies to IEC/EN STD (Europe).3. Class 3R applies to the Falcon 44xx using ALR (Advanced Long Range) Laser, only. 4. Class II applies to CDRH STD (US/Canada).5. Class IIA applies to CDRH STD (US/Canada).
Appendix E: Laser Safety54Falcon® 4400 Series with Windows® CEATTENTIONL’utilisation d’instruments optiques avec le scanneur augmente le danger pour les yeux. Les instruments optiques comprennent les jumelles, les microscopes et les verres grossissants. Ils ne comprennent pas les lunettes portées par l’utilisateur.GermanDieser Scanner ist den in den Vereinigten Staaten geltenden Vorschriften des DHHS/CDRH 21 CFR Subchapter J und den Vorschriften der IEC/EN 60825-1:1998-2001 entsprechend bescheinigt.Produkte der Klasse 1, 2, 3R, Klasse II oder der IIA sind als ungefährlich eingestuft. Im Inneren des Scanners befin-det sich eine VLD (Visible Laser Diode), deren Ausstrahlung die in den oben genannten Vorschriften angeführten Höchstgrenzen nicht überschreitet. Die Konstruktion des Scanners garantiert, daß bei normalem Betrieb, bei War-tung durch den Benutzer oder im Laufe planmäßiger Wartungsarbeiten kein Zugang zu schädlichem Laserlicht besteht.VORSICHT:Sollte das Abtastbild bei gedrücktem Auslöser aus einem einzigen Punkt bestehen, muß der Betrieb eingestellt und der Scanner an Datalogic zurückgesendet werden.VORSICHT:Unter keinen Umständen darf versucht werden, die Komponenten im Optikhohlraum zu öffnen oder auf irgendwelche andere Weise zu warten. Das Öffnen bzw. Warten der Komponenten im Optikhohlraum durch unbefugtes Personal verstößt gegen die Laser-Sicherheitsbestimmungen. Das Optiksystem darf nur werkseitig rep-ariert werden.VORSICHT:Die Verwendung von Optiksystemen mit diesem Scanner erhöht die Gefahr einer Augenbeschädigung. Zu optis-chen Instrumenten gehören unter anderem Ferngläser, Mikroskope und Vergrößerungsgläser, nicht aber die von Benutzern getragenen Brillen.ItalianÈ stato certificato che questo scanner si conforma ai requisiti della sezione J della normativa DHHS/CDRH 21CFR, e anche ai requisiti di IEC/EN 60825-1:1998-2001.I prodotti di Classe 1, 2, 3R, Classe II, o IIA non sono considerati pericolosi. Lo scanner contiene al suo interno un Visible Laser Diode (VLD), diodo laser visibile, le cui emissioni non eccedono i limiti stabiliti dalle normative sun-nominate. Lo scanner è progettato in modo che non ci sia alcun accesso alla luce dannosa del laser nel corso di uso normale, di manutenzione da parte dell’utente o durante la manutenzione periodica stabilita.ATTENZIONESe, quando si preme l’azionamento, il pattern di scansione è un punto singolo, interrompere l’operazione e ripor-tare lo scanner a Datalogic .ATTENZIONENon tentare di accedere allo scomparto contenete i componenti ottici o di farne la manutenzione. L’apertura dello scomparto, o la manutenzione di qualsiasi parte ottica da parte di personale non autorizzato, potrebbe violare le norme della sicurezza. Il sistema ottico può essere riparato solamente alla fabbrica.ATTENZIONEL’uso di strumenti ottici assieme allo scanner può aumentare il pericolo di danno agli occhi. Tali strumenti ottici includono cannocchiali, microscopi e lenti di ingrandimento. Essi non includono gli occhiali indossati dall’utente.DanishDenne scanner opfylder de amerikanske krav stillet i "DHHS/CDRH 21CFR Subchapter J" og opfylder også de krav, der stilles i IEC/EN 60825-1:1998-2001.
International Caution Statements for CLASS 1, 2, 3R, II, and IIA Laser DevicesQuick Reference Guide  55Klasse 1, 2, 3R, klasse II eller klasse IIA produkter anses for at være sikre. Scanneren indeholder en Visible Laser Diode (VLD), der ikke overskrider maksimumgrænserne, som beskrevet i ovenstående reglement. Scanneren er konstrueret, så der ikke er nogen menneskelig kontakt medskadelige niveauer af  laserbestråling under normal brug, normal vedligeholdelse eller under foreskrevet servicering.ADVARSELHvis scanningmønsteret er et enkelt punkt, når triggeren indtrykkes, skal betjening ophøre og scanneren returneres til Datalogic.ADVARSELForsøg ikke at åbne eller reparere komponenter i det optiske hulrum. Uautoriseret åbning eller reparation af komponenter i det optiske hulrum kan være en overtrædelse af lasersikkerhedsregulativer. Det optiske system må udelukkende repareres as Datalogic.ADVARSELAnvendelse af optiske systemer med scanneren øger risikoen for øjenskader. Optiske instruments omfatter kik-kerter, mikroskoper og lupper. Det omfatter ikke anvendelse af almindelige briller.Dutch Deze scanner is in de V.S. goedgekeurd en voldoet aan de vereisten van DHHS/CDRH 21CFR Subchapter J een aan de vereisten van IEC/EN 60825-1:1998-2001.Producten van klasse 1 ,2, 3R, klasse II en IIA worden niet geacht gevaarlijk te zijn.De scanner bevat een inwendige Visible Laser Diode (VLD) waarvan de emissies de maximumgrenzen van boven-staande reglementen niet overschrijden.De scanner is zo ontworpen dat men bij normaal gebruik, onderhoud of  tijdens het uitvoeren van de voorge-schreven onderhoudswerkzaamheden niet aan schadelijke niveaus wordt blootgesteld.WAARSCHUWINGAls het scanpatroon bij het overhalen van de trekker een enkele stip is, stop dan onmiddellijk en stuur de scanner terug naar Datalogic.WAARSCHUWINGProbeer niet om onderdelen in de opticaruimte te openen of er onderhoud aan uit te voeren. Het openen of onder-houden van delen in de opticaruimte door onbevoegd personeel kan een inbreuk vormen op de laserveiligheidsre-glementen. Het opticasysteem mag alleen in de fabriek worden gerepareerd.WAARSCHUWINGHet gebruik van optische systemen samen met de scanner vergroot het risico voor de ogen. Optische  instrumenten zijn onder andere binoculairs, microscopen en vergrootglazen, maar niet de bril die de gebruiker draagt.SwedishDenna scanner uppfyller de amerikanska kraven DHHS/CDRH 21CFR Subchapter J samt kraven i IEC/EN 60825-1:1998-2001.Produkter i Klass 1, 2, 3R, Klass II och IIA anses ej farliga. Scannern är utrustad med en intern, synlig laserdiod (Visible Laser Diode - VLD) vars emission inte överstiger max. värdena i ova stående säkerhetsföreskrifter. Scannern har konstruerats så att personer vid normal användning, bruksunderhåll och föreskriven service  inte utsätts för skadlig laserstrålning.VAR FÖRSIKTIGOm scanningsmönstret är en enda punkt när du trycker på avtryckaren, ska du avbryta användningen och ta scan-nerna tillbaka till Datalogic.VAR FÖRSIKTIGFörsök inte öppna eller reparera komponenter i den optiska kamaren. Om icke auktoriserad personal öppnar eller reparerar delar i den optiska kammaren, kan detta strida mot säkerhetsföreskrifterna för laserutrustning. Det optiska systemet får endast repareras på fabriken.
Appendix E: Laser Safety56Falcon® 4400 Series with Windows® CEVAR FÖRSIKTIGAnvändning av optiska system med scannern ökar risken för ögoskada. Optiska instrument inkluderar kikare, mik-roskop och förstoingsglas, men inte användarens glasögon.FinnishTämä tutkain on hyväksytty Yhdysvalloissa vastaamaan DHHS/CDRH 21CFR Subchapter J luokka 60825-1:1998-2001 IEC/EN-vaatimuksia.Luokka 1, 2, 3R, Luokka II tai IIAtuotteiden ei katsota olevan vaarallisia. Tutkain sisältää sisäisen näkyvän laserdio-din (Visible Laser Diode (VLD), jonka päästöt eivät ylitä yllä olevien säädösten asettamia maksimirajoja. Tutkain on suunniteltu siten, etteivät ihmiset altistu vaaralliselle lasersäteilylle normaalikäytön, käyttäjän suorittaman huol-lon tai ohjeiden mukaisten huoltotoimenpiteiden aikana.VAROITUSJos skannauskuva on yksittäinen piste laukaisinta painettaessa, keskeytä käyttö ja  palauta tutkain Datalogic:lle.VAROITUSÄlä yritä avata tai muuten huoltaa mitään rakenneosia optisessa osassa. Valtuuttamattoman henkilöstön suoritta-man  optisen osan avauksen tai huoltotoimen voidaan katsoa olevan rikkomus lasersuojaohjeita vastaan. Optisen järjestelmän saa korjata ainoastaan tehtaalla.VAROITUSMikäli optisia järjestelmiä käytetään tutkainmen kanssa, silmille aiheutuva vaara lisääntyy. Optiset kojeet käsittävät kiikarit, mikroskoopit ja suurennuslasit. Käyttäjän silmälasit eivät kuulu tähän ryhmään.NorwegianDenne skanneren er godkjent i USA i samsvar med retningslinjene for DHHS/CDRH 21CFR, avsnitt J, og til IEC/EN 60825-1:1998-2001.Produkter i klasse 1 2, 3R, klasse II eller IIA ansees ikke som helsefarlige. Skanneren inneholder en innvendig, syn-lig laserdiode (VLD, Visible Laser Diode), som ikke overskrider maksimalgrensene som er fastsatt i retningslinjene ovenfor. Skanneren er konstruert, slik at personer ikke utsettes for farlige doser med laserstråler ved normal drift, brukers vedlikehold eller ved foreskrevet service.OBS!Hvis skanningsmønsteret består av én enkel prikk når utløseren trykkes inn, skal driften stanses, og skanneren settes tilbake til Datalogic.OBS!Prøv ikke å åpne eller på noen måte utføre service på noen av delene i det optiske kammeret. Ved å åpne eller utføre service på noen av delene i det optiske kammeret av uautorisert personell, kan krenke forskriftene for lasersikkerhet. Optikksystemet skal bare repareres på fabrikken.OBS!Bruk av optiske systemer med skanneren kan innebære høyere fare for øynene. Optiske instrumenter innbefatter, kikkerter, mikroskop og forstørrelsesglass. Dette omfatter ikke briller som brukeren har på seg.PortugueseEste scanner foi certificado nos EUA para atender os requisitos do subcapítulo J do DHHS/CDRH 21 CFR e os requisitos do IEC/EN 60825-1:1998-2001.Os produtos da Classe 1, 2, 3R, Classe II ou IIA não são considerados perigosos. O scanner contém internamente um Diodo de Laser Visível (VLD - Visible Laser Diode) cujas emissões não ultrapassam os limites definidos nos regulamentos mencionados acima. O scanner foi projetado de maneira que não exista acesso humano à luz de laser nociva durante a operação normal, manutenção pelo usuário ou durante as operações recomendadas de serviço.
International Caution Statements for CLASS 1, 2, 3R, II, and IIA Laser DevicesQuick Reference Guide  57CUIDADOSe ao pressionar o gatilho a luz do laser for um único ponto, interrompa a operação e devolva o scanner à Datalogic.CUIDADONão tente abrir ou consertar qualquer componente da cavidade óptica. A abertura ou manutenção de qualquer peça da cavidade óptica por pessoal não autorizado pode infringir os regulamentos de segurança do laser. O sistema óptico só deve ser reparado na fábrica.CUIDADOO uso de instrumentos ópticos com o scanner aumenta o risco para a visão. Incluem-se entre os instrumentos ópti-cos os binóculos, microscópios e lentes de aumento. Não se incluem os óculos usados pelo usuário.SpanishEste escáner está certificado en los EE.UU. porque reúne los requisitos DHHS/CDRH 21CFR Sección J y los req-uisitos de IEC/EN 60825-1:1998-2001.Los productos de Clase 1, 2, 3R, Clase II, o IIA no se consideran como peligrosos. El escáner tiene en su interior un Diodo Láser Visible (VLD) cuyas emisiones no exceden los límites máximos fijados en los reglamentos menciona-dos anteriormente. El escáner está diseñado de modo que las personas no tengan acceso a la luz láser peligrosa durante la operación normal, el mantenimiento por parte del usuario o durante las operaciones de servicio prescri-tas.PRECAUCIÓNSi al oprimir el interruptor, el patrón de exploración es un solo punto, discontinúe el uso y devuelva el escáner a Datalogic.PRECAUCIÓNNo intente abrir o de ninguna manera dar servicio a ninguno de los componentes del receptáculo óptico. Abrir o dar servicio a las piezas del receptáculo óptico por parte del personal no autorizado podría ser una violación a los reglamentos de seguridad. El sistema óptico se puede reparar en la fábrica solamente.PRECAUCIÓNEl uso de sistemas ópticos con el escáner aumentará el riesgo de daños oculares. Los instrumentos ópticos incluyen binoculares, microscopios y lupas. Esto no incluye los lentes recetados usados por el usuario.ChineseDatalogic
Appendix E: Laser Safety58Falcon® 4400 Series with Windows® CEJapaneseDatalogic
International Caution Statements for CLASS 1, 2, 3R, II, and IIA Laser DevicesQuick Reference Guide  59NOTES
Appendix E: Laser Safety60Falcon® 4400 Series with Windows® CENOTES
DECLARATION OF CONFORMITYDatalogic hereby declares that the Equipment specified below has been tested and found compliant to the following Directives and Standards:EU Directives: 89/336/EEC EMC73/23/EEC Low VoltageR&TTE 1999/5/ECStandards: EN300 328:2004 - Radio55022:2001/2003 - Generic EmissionEN55024:2001 - Generic ImmunityEN300 489-17:2002 - Radio ImmunityEN60950-1:2000/2001 - ITE SafetyEN60825-1/A2:2001 - Laser SafetyEquipment Type: Mobile Computer or Portable Data TerminalProduct Model Name: F al co n  44 10 a nd  44 20  RoH S v ers io n w ith  an d                                                                        without Wistron and Bluegiga radio card optionsPlaced into EU Service: April 2007 under the Datalogic trademark.  2003                                                                           under the PSC trademark.Responsible Manufacturer: Datalogic Mobile, Inc. 1505 Westec Dr. Eugene, OR USADeclaration of Conformity with Regard to the R&TTE Directive 1999/5/ECEnglish: This equipment is in compliance with the essential requirements & other relevant provisions of Directive 1999/5/EC. Nederlands: Deze apparatuur voldoet aan de essentiële vereisten en andere relevante voorzieningen van EU-richtlijn 1999/5/EC.Suomalainen: Tämä laite noudattaa direktiivin 1999/5/EC keskeisiä vaatimuksia ja sen muita olennaisia määräyksiä.Français: Cet équipement répond aux exigences et provisions de la Directive 1999/5/EC.Deutsch: Diese Geräte entsprechen den Anforderungen und anderen relevanten Bestimmungen der Richtlinie 1999/5/EC.Italiano: Questa apparecchiatura rispetta i requisiti essenziali e le altre clausole rilevanti della Direttiva 1999/5/CE.Dansk: Dette utstyret er i samsvar med de grunnleggende kravene og andre relevante forskrifter i 1999/5/EC-direktivet.Português: Este equipamento está de acordo com os requisitos essenciais e outras provisões relevantes da Diretiva 1999/5/EC.Español: Este equipo cumple con los requisitos esenciales y otras provisiones relevantes de la Directiva 1999/5/EC.Svenska: Denna utrustning uppfyller de väsentliga kraven och andra relevanta förordningar i Direktiv 1999/5/EC.Norsk: Dette utstyret er i samsvar med de grunnleggende krav og andre relevante bestemmelser i EU-direktiv 1999/5/EFlslenska: Þetta taeki er samkvaemnt grunnkröfum og öðrum viðeigandi ákvaðum Tilskipunar 1999/5/CE.
Corporate Headquarters Datalogic S.p.A.Via Candini, 240012 Lippo di Calderara di RenoBologna - ItalyTelephone: +39 051 3147011Fax: +39 051 726562Datalogic Mobile, Inc.1505 Westec Dr.Eugene, OR 97402Telephone: (541) 743-4800Fax: (541) 743-4900www.mobile.datalogic.com©2007 Datalogic Mobile, Inc. R44-2695 (Rev B) 07/07