Datalogic Scanning Ds2400N Users Manual DS2400N_Quick Guide
DS2400N to the manual 10c5e373-d49e-4698-b054-3839a6d4914e
2015-02-02
: Datalogic-Scanning Datalogic-Scanning-Ds2400N-Users-Manual-425519 datalogic-scanning-ds2400n-users-manual-425519 datalogic-scanning pdf
Open the PDF directly: View PDF .
Page Count: 19
Download | |
Open PDF In Browser | View PDF |
DS2400N QUICK REFERENCE GUIDE 4 2 5 6 3 7 11 10 9 1 8 Figure A NOTE 1 Warning and Device Class Labels 7 Laser Beam Output Window 2 "POWER ON" LED 8 "COM" LED 3 Mounting Holes 9 "STATUS" LED 4 "READY" LED 10 Push Button 5 "GOOD" LED 11 Accessory Mounting Holes 6 "TRIGGER" LED This manual illustrates a Stand Alone application. For other types of installations, such as ID-NET™, Pass-Through, Multiplexer Layout, etc. and for a complete scanner configuration using Genius™ configuration program, refer to the DS2400N Reference Manual available on the CD. This manual is also downloadable from the Web at www.automation.datalogic.com/ds2400n. DS2400N QUICK GUIDE UPDATES AND LANGUAGE AVAILABILITY UK/US The latest drivers and documentation updates for this product are available on Internet. Log on to: www.automation.datalogic.com I Su Internet sono disponibili le versioni aggiornate di driver e documentazione di questo prodotto. Questo manuale è disponibile anche nella versione italiana. Collegarsi a: www.automation.datalogic.com F Les versions mises à jour de drivers et documentation de ce produit sont disponibles sur Internet. Ce manuel est aussi disponible en version française. Cliquez sur : www.automation.datalogic.com D Im Internet finden Sie die aktuellsten Versionen der Treiber und Dokumentation von diesem Produkt. Die deutschsprachige Version dieses Handbuches ist auch verfügbar. Adresse : www.automation.datalogic.com E En Internet están disponibles las versiones actualizadas de los drivers y documentación de este producto. También está disponible la versión en español de este manual. Dirección Internet : www.automation.datalogic.com SERVICES AND SUPPORT Datalogic provides several services as well as technical support through its website. Log on to www.automation.datalogic.com and click on the links indicated for further information including: • PRODUCTS Search through the links to arrive at your product page where you can download specific Manuals and Software & Utilities including: - Genius™ a utility program, which allows device configuration using a PC. It provides RS232 interface configuration. • SERVICES & SUPPORT - Datalogic Services - Warranty Extensions and Maintenance Agreements - Authorised Repair Centres • CONTACT US E-mail form and listing of Datalogic Subsidiaries 2 DS2400N QUICK GUIDE STEP 1 – CONNECT THE SYSTEM To connect the system in a Stand Alone configuration, you need the hardware indicated in Figure 1. In this layout the data is transmitted to the Host on the main serial interface. In Local Echo communication mode, the RS232 auxiliary interface can be used to transmit data independently from the main interface selection. When On-Line Operating mode is used, the scanner is activated by an External Trigger (photoelectric sensor) when the object enters its reading zone. PG 6000 MAIN CBX100/500 DS2400N Host P.S.* * Presence Sensor (for On-Line mode) I/O, AUX Figure 1 – DS2400N in Stand Alone Layout CBX100/500 Pinout for DS2400N The table below gives the pinout of the CBX100/500 terminal block connectors. Use this pinout when the DS2400N reader is connected by means of the CBX100/500: CBX100/500 Terminal Block Connectors Vdc GND Earth +V I1A I1B -V +V I2A I2B -V Shield Power Power Supply Input Voltage + Power Supply Input Voltage Protection Earth Ground +V -V O1+ O1O2+ O2- Inputs Power Source – External Trigger External Trigger A (polarity insensitive) External Trigger B (polarity insensitive) TX Power Reference – External Trigger RX Power Source – Inputs SGND Input 2 A (polarity insensitive) Input 2 B (polarity insensitive) REF Power Reference – Inputs ID+ Shield IDNetwork Cable Shield Main Interface RS232 RS485 Full-Duplex TX TX+ RTS TX*RX+ RX *RXCTS SGND SGND Outputs Power Source - Outputs Power Reference - Outputs Output 1 + Output 1 Output 2 + Output 2 Auxiliary Interface Auxiliary Interface TX Auxiliary Interface RX Auxiliary Interface Reference ID-NET™ Network Reference ID-NET™ network + ID-NET™ network - RS485 Half-Duplex RTX+ RTX- SGND * Do not leave floating, see Reference Manual for connection details. CAUTION Do not connect GND, SGND and REF to different (external) ground references. GND, SGND and REF are internally connected through filtering circuitry which can be permanently damaged if subjected to voltage drops over 0.8 Vdc. 3 DS2400N QUICK GUIDE 25-pin Connector Pinout for DS2400N The table below gives the pinout of the 25-pin male D-sub connector for connection to the power supply and input/output signals. Use this pinout when the DS2400N reader is connected by means of the 25-pin connector: 1 13 14 25 Figure 2 - 25-pin Male D-sub Connector 25-pin D-sub male connector pinout Pin 13, 9 25, 7 1 18 19 6 10 8 22 11 12 20 21 23 24 14, 15, 16, 17 Name Function Vdc GND CHASSIS I1A I1B I2A I2B O1+ O1O2+ O2RX TX ID+ IDNC Power supply input voltage + Power supply input voltage Cable shield connected to chassis External Trigger A (polarity insensitive) External Trigger B (polarity insensitive) Input 2 A (polarity insensitive) Input 2 B (polarity insensitive) Output 1 + Output 1 Output 2 + Output 2 Auxiliary RS232 RX Auxiliary RS232 TX ID-NET™ network + ID-NET™ network Not Connected RS485 RS232 Full-Duplex TX TX+ *RX+ RX RTS TX*RXCTS Pin Name 2 3 4 5 MAIN INTERFACE (SW SELECTABLE) * Do not leave floating, see Reference Manual for connection details. 4 RS485 Half-Duplex RTX+ RTX- DS2400N QUICK GUIDE STEP 2 – MOUNT AND POSITION THE SCANNER 1. To mount the DS2400N, use the mounting bracket to obtain the most suitable position for the reader as shown in the figures below. Skew Pitch Tilt Skew 2. Figure 3 - Positioning with Mounting Bracket When mounting the DS2400N take into consideration these three ideal label position angles:, Skew 10° to 30°, Tilt 0° and Pitch 0°. P T S Assure at least 10° Minimize Minimize Figure 4 –, Skew, Tilt and Pitch Angles 3. Refer to the Reading Diagrams in the Appendix of this Quick Reference Guide to decide the distance your scanner should be positioned at. 5 DS2400N QUICK GUIDE STEP 3 – X-PRESS™ CONFIGURATION X-PRESS™ is the intuitive Human Machine Interface designed to improve ease of installation and maintenance. Status and diagnostic information are clearly presented by means of the five colored LEDs, whereas the single push button gives immediate access to the following relevant functions: • Test Mode with bar graph visualization to check static reading performance • AutoLearn to self-detect and auto-configure for reading unknown barcodes (by type and length) • AutoSetup to self-optimize and auto-configure reading performance in demanding applications NOTE If using the OM2000N accessory, when entering the X-PRESS™ interface, the Oscillating Mirror remains in the default fixed position (-15°) in order to make barcode reading easier while performing the X-PRESS™ functions. The colors and meaning of the five LEDs are illustrated in the following table: READY (green) GOOD (green) TRIGGER (yellow) COM (yellow) STATUS (red) This LED indicates the device is ready to operate. This LED confirms successful reading. This LED indicates the status of the reading phase. This LED indicates active communication on main serial port. This LED indicates a NO READ result. During the reader startup (reset or restart phase), all the LEDs blink for one second. On the back of the reader near the cable, the “POWER ON” LED indicates the laser scanner is correctly powered. AUTO LEARN If you are configuring your scanner using X-PRESS™, you must start with the Auto Learn procedure. 1. Enter the Auto Learn function by holding the X-PRESS™ push button pressed until the LEARN LED is on. 2. Release the button to enter the Auto Learn function. Once entered, the reader starts a procedure to automatically detect and recognize barcodes (by type and length), which are presented to it (*). The laser turns on and the LEARN LED blinks to indicate the ongoing process. READY SETUP LEARN TEST GOOD TRIGGER COM STATUS green green yellow yellow red Figure 5 – X-PRESS™ Interface: Auto Learn Function The procedure is as follows: A) place the desired barcode on the scanline. B) wait until the LEARN LED stays steady on (indicating the reader has detected the barcode). C) repeat, if needed, the above two steps to program up to 10 different barcodes (the LEARN LED returns to the blinking state for the next code). If more than one barcode is detected, the Multi Label mode is enabled (refer to the “2K/4K Family Software Configuration Parameter Guide” Help file). * In case of Programming Barcodes, refer to the “ID-NET™ Programming Barcodes And Setup Procedure” document in the product CD. 6 DS2400N QUICK GUIDE 3. Exit the process by pressing the X-PRESS™ push button once. The scanner will restart at the end of the process, and then the detected barcodes are automatically configured in scanner memory. NOTE If the barcode cannot be read because of low contrast or excessive ambient light, you can perform the AutoSetup function to optimize the optical parameters. Then you can perform AutoLearn to recognize the barcode symbology. AUTO SETUP (OPTIONAL) At the end of the Auto Learn procedure, you have the possibility to follow the Auto Setup procedure to set up the reading parameters. 1. Enter the Auto Setup function by holding the X-PRESS™ push button pressed until the SETUP LED is on. 2. Release the button to enter the Auto Setup function. Once entered, if a barcode label is positioned in front of the scanline, the scanner automatically performs the optimal setup of the reading parameters for that specific barcode. READY SETUP LEARN TEST GOOD TRIGGER COM STATUS green green yellow yellow red The procedure is as follows: A) place the desired barcode on the scanline. B) enter the AutoSetup function (the laser turns on and the SETUP LED blinks to indicate the ongoing process) C) wait until the SETUP LED stays steady on (indicating the reader has detected the barcode) Figure 6 – X-PRESS™ Interface: Auto Setup Function This procedure ends either when the barcode is successfully decoded or after a timeout of about 7 (seven) seconds. The scanner will restart at the end of the process, and then the optimized reading parameters for that barcode are automatically configured in scanner memory. If your application has been configured using X-PRESS™, go to STEP 5. NOTE RESET SCANNER TO FACTORY DEFAULT (OPTIONAL) If it ever becomes necessary to reset the scanner to the factory default values, you can perform this procedure by holding the X-PRESS™ push button pressed while powering up the scanner. At the end of the procedure (about 5-6 seconds), the Configuration and Environmental parameters are reset and all LEDs blink simultaneously 3 times. If connected through a CBX500 with display module, the message "Default Set" is shown on the display. 7 DS2400N QUICK GUIDE STEP 4 – INSTALL GENIUS™ CONFIGURATION PROGRAM Genius™ is a Datalogic scanner configuration tool providing several important advantages: • Wizard approach for new users; • Multi-language version; • Defined configuration directly stored in the reader; • Communication protocol independent from the physical interface allowing to consider the reader as a remote object to be configured and monitored. To install Genius™, turn on the PC that will be used for the configuration, running Windows 98, 2000/NT, XP or Vista, then insert the Genius™ CD-ROM, wait for the CD to autorun and follow the installation procedure. This configuration procedure assumes scanner connection to a CBX100/500. Genius™, running on a laptop computer, is connected to the scanner auxiliary port through the CBX100/500 9-pin connector. To communicate with the scanner, Genius™ performs an auto baudrate detection starting from its default parameters which are 115200, 8, N, 1. These parameters can also be set in the Genius™ Tools>Options>Communications window. WIZARD FOR QUICK READER SETUP After installing the Genius™ software program the following window appears asking the user to choose the desired configuration level. Figure 7 - Genius™ Wizard Opening Window The Wizard option is advised for rapid configuration or for new users, since it shows a step-by-step scanner configuration. 1. Select the Create a new configuration button. You will be guided through the configuration being asked to define the following parameters: 8 DS2400N QUICK GUIDE a. Barcode selection and definition b. Operating mode selection and definition c. Digital Outputs configuration d. Hardware interface selection e. Output data format configuration The On Line operating Mode requires the reader to be connected to an External Trigger/Presence Sensor using I1A and I1B inputs. The Automatic operating mode does not require connection to an external Presence Sensor. When working in this mode the reader is continuously scanning, while the reading phase is activated each time a barcode enters the reader reading zone. The reader stops reading after an N number of scans without a code. Barcode characters are transmitted on the serial interface. In case of a failed reading phase no message is sent to the host computer. 9 DS2400N QUICK GUIDE 2. After defining the parameter values the following window appears allowing to complete the reader configuration as follows: • Saving the configuration to disk; • Switching to Advanced mode; • Sending the configuration to the scanner. 3. After sending the configuration to the scanner you have completed the configuration process. 4. By clicking Finish, the System Information window will be displayed with specific information concerning the scanner. 10 DS2400N QUICK GUIDE STEP 5 – TEST MODE Use a code suitable to your application to test the system. Alternatively, you can use the Datalogic Test Chart (Code 39, Code Interleaved 2/5). 1. Enter the Test mode function by holding the X-PRESS™ push button pressed until the TEST LED is on. 2. Release the button to enter the Test mode function. Once entered, the Bar-Graph on the five LEDs is activated and if the scanner starts reading barcodes the Bar-Graph shows the Good Read Rate. In case of no read condition, only the STATUS LED is on and blinks. READY SETUP LEARN TEST GOOD TRIGGER COM STATUS green green yellow yellow red Figure 8 – X-PRESS™ Interface: Test Mode Function 3. To exit the Test Mode, press the X-PRESS™ push button once. By default, the Test Mode exits automatically after two minutes. NOTE 11 DS2400N QUICK GUIDE ADVANCED SCANNER CONFIGURATION For further details on advanced product configuration, refer to the complete Reference Manual on the installation CD-ROM or downloadable from the web site through this link: www.automation.datalogic.com/ds2400n. The following are alternative or advanced scanner configuration methods: HOST MODE PROGRAMMING The scanner can also be configured from a host computer using the Host Mode programming procedure, by commands via the serial interface. See the Host Mode Programming file on the CD-ROM. ADVANCED GENIUS™ CONFIGURATION The ADVANCED selection available when starting the Genius™ program is addressed to expert users being able to complete a detailed scanner configuration. By choosing this option it is possible either to start a new scanner configuration or to open and modify an old one. The desired parameters can be defined in the following window, similar to the MS Explorer: Figure 9 - Genius™ Parameter Explorer Window ALTERNATIVE LAYOUTS • The ID-NET™ network is a built-in high-speed interface dedicated for high-speed scanner interconnection. ID-NET™ is in addition to the Main and Auxiliary serial interfaces. If you need to install an ID-NET™ network refer to the DS2400N Reference Manual. The scanner can also be configured by reading programming barcodes. See the ID-NET™ Setup Procedure Using Programming Barcodes printable from the CD-ROM. • If you need to install a Pass-Through network refer to the DS2400N Reference Manual. • If you need to install a Multiplexer network refer to the DS2400N Reference Manual. • If you need to install an RS232 Master/Slave (for backward compatibility) refer to the DS2400N Reference Manual. 12 DS2400N QUICK GUIDE APPENDIX READING DIAGRAMS DS2400N-0200 (Short Reading Range) CONDITIONS Optic Version = Linear Code = Interleaved 2/5 or Code 39 PCS = 0.90 Pitch angle = 0° Skew angle = 10° Tilt angle = 0° * Code Resolution = High * Reading Conditions = Standard * Scan Speed = 800 scans/s * Parameter selectable in Genius™ (0,0) corresponds to the scanner output window 4 10 3 7,5 2 5 1 2,5 0 0 1 2,5 2 5 3 7,5 4 in cm 2 4 5 10 6 10 8 15 20 14 in 12 25 30 35 cm ≥0.35 mm (14 mils) 0.20 mm (8 mils) 0.25 mm (10 mils) 10 DS2400N-1200 (Medium Reading Range) 4 10 8 20 12 30 20 16 40 50 cm CONDITIONS Optic Version = Linear Code = Interleaved 2/5 or Code 39 PCS = 0.90 Pitch angle = 0° Skew angle = 10° Tilt angle = 0° * Code Resolution: High – for 0.25 mm (10 mils) codes Std – for 0.35 mm (14 mils) codes and greater * Reading Conditions = Standard * Scan Speed = 800 scans/s 8 20 6 15 4 10 2 5 0 0 2 5 * 4 Parameters selectable in Genius™ (0,0) corresponds to the scanner output window 6 8 in ≥0.50 mm (20 mils) 0.25 mm (10 mils) 10 15 0.35 mm (14 mils) 20 cm 13 DS2400N QUICK GUIDE DS2400N-2200 (Long Reading Range) CONDITIONS Optic Version = Linear Code = Interleaved 2/5 or Code 39 PCS = 0.90 Pitch angle = 0° Skew angle = 10° Tilt angle = 0° * Code Resolution: High – for 0.35 mm (14 mils) codes Std – for 0.50 mm (20 mils) codes and greater * Reading Conditions = Standard * Scan Speed = 800 scans/s • Parameters selectable in Genius™ (0,0) corresponds to the scanner output window 14 8 20 6 15 4 10 2 5 0 0 2 5 4 10 6 15 4 8 12 16 20 24 28 in 10 20 30 40 50 60 70 cm 0.35 mm 8 20 in cm (14 mils) ≥ 0.50 mm (20 mils) DS2400N QUICK GUIDE READING PERFORMANCE Version 0XX0 1XX0 2XX0 Reading Distance 75 mm (3 in) - 340 mm (13.4 in) on 0.35 mm (14 mils) codes 100 mm (3.9 in) - 440 mm (17.3 in) on 0.50 mm (20 mils) codes 190 mm (7.5 in) - 600 mm (23.6 in) on 0.50 mm (20 mils) codes Max Code Resolution mm (mils) 0.20 (8) 0.25 (10) 0.35 (14) Speed scans/s 600 to 1000 600 to 1000 600 to 1000 TECHNICAL FEATURES ELECTRICAL FEATURES Power Supply Consumption Main Serial Interfaces Baud Rate Auxiliary Interface Baud Rate ID-NET™ Interface Baud Rate Inputs Input 1 (External Trigger), Input 2 Voltage Current Consumption Minimum Pulse Duration Outputs Output 1, Output 2 VCE Collector Current VCE Saturation Power Dissipation 10 to 30 Vdc 0.5 to 0.17 A; 5 W Programmable: RS232, RS485 FD and HD 1200 to 115200 RS232 1200 to 115200 RS485 Half Duplex Up to 1 Mbaud Optocoupled, polarity insensitive 10 to 30 Vdc 12 mA max. 5 ms Optocoupled 30 Vdc max. 40 mA continuous max.; 130 mA pulsed max. 1V max. at 10 mA 80 mW max. at 45 °C (ambient temperature) READING FEATURES Scan Rate (software programmable) Aperture Angle Maximum Reading Distance Maximum Resolution 600 to 1000 scans/sec 50° See reading diagrams ENVIRONMENTAL FEATURES Operating Temperature c 0° to +45 °C (+32° to +113 °F) Storage Temperature Humidity max. -20° to +70 °C (-4° to +158 °F) 90% non condensing Vibration Resistance EN 60068-2-6 Bump Resistance EN 60068-2-29 Shock Resistance EN 60068-2-27 Protection Class EN 60529 14 mm @ 2 to 10 Hz; 1.5 mm @ 13 to 55 Hz; 2 g @ 70 to 200 Hz; 2 hours on each axis 30 g; 6 ms; 5000 shocks on each axis 30 g; 11 ms; 3 shocks on each axis IP65 PHYSICAL FEATURES Dimensions Weight 68 x 84 x 34 mm (2.68 x 3.31 x 1.34 in) 330 g (11.6 oz) USER INTERFACE LED Indicators Multi-function Key Ready, Good, Trigger, Com, Status, Power On X-PRESS™ button c If the reader is used in high temperature environments (over 40 °C), use of the Beam Shutter is advised (see the Genius™ configuration program) and/or a thermally conductive support (such as the metal bracket provided). 15 DS2400N QUICK GUIDE MECHANICAL DIMENSIONS 84 3.31 23.3* 0.92 4 0.16 10.3 0.41 10.3 0.41 14 0.55 14.7 0.58 M 4 n° 4 DS2400N GOOD 40 1.57 68 2.68 46 1.81 40 1.57 READY SETUP TRIGGER LEARN COM TEST STATUS X PRESS 32.7 1.29 INTERFACE mm inch * The quote refers to the scan line Figure 10 – DS2400N Overall Dimensions 9 2.5 mm Figure 11 – Mounting Bracket Overall Dimensions 16 4.2 n° 2 4. 2 2.5 17.5 30 73 40 20° 13.8 R 42 90° 1 x 45° n° 2 7.8 4.2 23 DS2400N QUICK GUIDE COMPLIANCE LASER SAFETY This product conforms to the applicable requirements of IEC 60825-1 and complies with 21 CFR 1040.10 except for deviations pursuant to Laser Notice N° 50, date June 24, 2007. The scanner is classified as a Class 2 laser product according to IEC 60825-1 regulations. Complies with 21 CFR 1040.10 except for deviations pursuant to Laser Notice N°50, date June 24, 2007 Disconnect the power supply when opening the device during maintenance or installation to avoid exposure to hazardous laser light. There is a safety device, which allows the laser to be switched on only if the motor is rotating above the threshold for its correct scanning speed. The laser beam can be switched off through a software command (see also the Genius Help On Line). LASER LIGHT DO NOT STARE INTO BEAM CLASS 2 LASER PRODUCT The laser diode used in this device is classified as a class 3B laser product according to EN 60825-1 regulations and as a Class IIIb laser product according to CDRH regulations. MAX. OUTPUT RADIATION 1 mW EMITTED WAVE LENGTH 630~680 nm TO IEC 60825-1:1993+A1:1997+A2:2001 Any violation of the optic parts in particular can cause radiation up to the maximum level of the laser diode (35 mW at 630 to 680 nm). CAUTION-CLASS 3B LASER LIGHT WHEN OPEN AVOID EXPOSURE TO BEAM Pat. US5992740, EP0789315B1 DATALOGIC AUTOMATION S.r.l. Via S. Vitalino, 13 – 40012 Calderara di Reno MADE IN ITALY-www.datalogic.com AVOID EXPOSURE LASER LIGHT IS EMITTED FROM THIS APERTURE Figure 12 - Warning and Device Class Labels FCC COMPLIANCE Modifications or changes to this equipment without the expressed written approval of Datalogic could void the authority to use the equipment. This device complies with PART 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference which may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. POWER SUPPLY This product is intended to be installed by Qualified Personnel only. This accessory device is intended to be supplied by a UL Listed or CSA Certified Power Unit with «Class 2» or LPS power source, which supplies power directly to the scanner via the 25-pin connector. CE COMPLIANCE Warning: This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. 17 DS2400N QUICK GUIDE PATENTS This product is covered by one or more of the following patents: U.S. patent: 5,992,740 European patent: 789,315 B1 18 DECLARATION OF CONFORMITY 08 Datalogic Automation S.r.l. Via S. Vitalino 13 40012 - Lippo di Calderara Bologna - Italy dichiara che declares that the déclare que le bescheinigt, daß das Gerät declare que el e tutti i suoi modelli and all its models et tous ses modèles und seine Modelle y todos sus modelos DS2400N Laser Scanner; sono conformi alle Direttive del Consiglio Europeo sottoelencate: are in conformity with the requirements of the European Council Directives listed below: sont conformes aux spécifications des Directives de l'Union Européenne ci-dessous: der nachstehend angeführten Direktiven des Europäischen Rats: cumple con los requisitos de las Directivas del Consejo Europeo, según la lista siguiente: 89/336/EEC EMC Directive e and et und y 92/31/EEC, 93/68/EEC emendamenti successivi further amendments ses successifs amendements späteren Abänderungen succesivas enmiendas Basate sulle legislazioni degli Stati membri in relazione alla compatibilità elettromagnetica ed alla sicurezza dei prodotti. On the approximation of the laws of Member States relating to electromagnetic compatibility and product safety. Basée sur la législation des Etats membres relative à la compatibilité électromagnétique et à la sécurité des produits. Über die Annäherung der Gesetze der Mitgliedsstaaten in bezug auf elektromagnetische Verträglichkeit und Produktsicherheit entsprechen. Basado en la aproximación de las leyes de los Países Miembros respecto a la compatibilidad electromagnética y las Medidas de seguridad relativas al producto. Questa dichiarazione è basata sulla conformità dei prodotti alle norme seguenti: This declaration is based upon compliance of the products to the following standards: Cette déclaration repose sur la conformité des produits aux normes suivantes: Diese Erklärung basiert darauf, daß das Produkt den folgenden Normen entspricht: Esta declaración se basa en el cumplimiento de los productos con las siguientes normas: EN 55022 (Class A ITE), September 1998: INFORMATION TECHNOLOGY EQUIPMENT RADIO DISTURBANCE CHARACTERISTICS LIMITS AND METHODS OF MEASUREMENTS EN 61000-6-2, September 2005: ELECTROMAGNETIC COMPATIBILITY (EMC) PART 6-2: GENERIC STANDARDS - IMMUNITY FOR INDUSTRIAL ENVIRONMENTS Lippo di Calderara, January 29th, 2008 Lorenzo Girotti Product & Process Quality Manager 821001324 (Rev. D)
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Encryption : Standard V2.3 (128-bit) User Access : Print, Copy, Extract, Print high-res Page Count : 19 XMP Toolkit : XMP toolkit 2.9.1-14, framework 1.6 About : uuid:3aaade4e-d5b6-4d64-97ec-4b54f989203b Producer : Acrobat Distiller 6.0.1 (Windows) Create Date : 2008:05:20 10:46:42+02:00 Creator Tool : PScript5.dll Version 5.2 Modify Date : 2008:05:20 11:11:00+02:00 Metadata Date : 2008:05:20 11:11:00+02:00 Document ID : uuid:aca0bb17-3d7d-44fc-b832-3af01216ea1e Format : application/pdf Creator : ESchino Title : DS2400N_Quick Guide Author : ESchinoEXIF Metadata provided by EXIF.tools