Datalogic 0002 GRYPHON M Series Readers User Manual a Gryphon M Master

Datalogic SpA GRYPHON M Series Readers a Gryphon M Master

manual

GRYPHON™M SERIES READERSQuick ReferenceInstallazione RapidaManuel d'Installation RapideSchnellinstallationManual de Instalación Rápida
DATALOGIC S.p.A.,Via Candini, 240012 - Lippo di CalderaraBologna - Italydichiara chedeclares that thedéclare que lebescheinigt, daß das Gerätdeclare que elGRYPHON M100, Cordless bar code readerGRYPHON M200, Cordless bar code readere tutti i suoi modelliand all its modelset tous ses modèlesund seine modelley todos sus modelossono conformi alle Direttive del Consiglio Europeo sottoelencate:are in conformity with the requirements of the European Council Directives listed below:sont conformes aux spécifications des Directives de l'Union Européenne ci-dessous:den nachstehenden angeführten Direktiven des Europäischen Rats entsprechen:cumple con los requisitos de las Directivas del Consejo Europeo, según la lista siguiente:1999/5/EEC R&TTEQuesta dichiarazione è basata sulla conformità dei prodotti alle norme seguenti:This declaration is based upon compliance of the products to the following standards:Cette déclaration repose sur la conformité des produits aux normes suivantes:Diese Erklärung basiert darauf, daß das Produkt den folgenden Normen entspricht:Esta declaración se basa en el cumplimiento de los productos con las siguientes normas:EN 60950, October 1996:SAFETY OF INFORMATION TECHNOLOGY EQUIPMENT,  INCLUDINGELECTRICAL BUSINESS EQUIPMENTETS 300 683, June 1997:RADIO  EQUIPMENT AND SYSTEMS  (RES); ELECTROMAGNETICCOMPATIBILITY  (EMC)  STANDARD FOR SHORT  RANGE  DEVICES(SRD)  OPERATING ON FREQUENCIES BETWEEN 9 KHZ AND 25GHZETS 300 220-1, November 1997:ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUMMATTERS  (ERM); SHORT  RANGE  DEVICES; TECHNICALCHARACTERISTICS AND TEST METHODS FOR RADIO EQUIPMENT TOBE USED IN THE 25 MHZ TO 1000 MHZ FREQUENCY RANGE WITHPOWER LEVELS RANGING UP TO 500 MW; PART 1: PARAMETERSLippo di Calderara, 13.03.2001Ruggero CacioppoQuality Assurance SupervisorDatalogic reserves the right to make modifications and improvements without prior notification.Product names mentioned herein are for identification purposes only and may be trademarks and orregistered trademarks of their respective companies.© - 2001 Datalogic S.p.A.PRELIMINARY
iiiCONTENTSServices Available at Our Website .................................................................2Using Gryphon™ Readers .............................................................................3Charging the Batteries....................................................................................4Gryphon™ Configuration................................................................................5Gryphon™ Default Configuration....................................................................7Technical Features.........................................................................................8Warranty ........................................................................................................9Patents...........................................................................................................9Information to the Users ...............................................................................10LED Class....................................................................................................10Reading Diagram .........................................................................................47Numeric Table..............................................................................................48INDICEDisponibili nel Nostro Sito Web ....................................................................12Descrizione e Uso........................................................................................13Carica e Installazione delle Batterie..............................................................14Configurazione del Gryphon™ .....................................................................15Gryphon™ - Configurazione di Default .........................................................17Caratteristiche Tecniche...............................................................................18Garanzia ......................................................................................................19Avvertenze ...................................................................................................19Classe del LED ............................................................................................19Diagramma di Lettura...................................................................................47Tabella Numerica.........................................................................................48SOMMAIREDisponibles dans Notre Site Web.................................................................21Description et Utilisation...............................................................................22Charge et Installation de la Batterie..............................................................23Configuration du Gryphon™.........................................................................24Gryphon™ - Configuration par Defaut ..........................................................26Caracteristiques Techniques ........................................................................27Garantie .......................................................................................................28Precautions..................................................................................................28Classe du LED .............................................................................................28Abaque de Lecture.......................................................................................47Tableau Numerique......................................................................................48
ivINHALTSVERZEICHNISVerfügbar auf Unserem Web Site.................................................................30Beschreibung und Gebrauchsanweisung .....................................................31Ladung der Akkus ........................................................................................32Gryphon™ Konfiguration..............................................................................33Gryphon™ - Grundeinstellung......................................................................35Technische Daten ........................................................................................36Gewährleistung ............................................................................................37Hinweise ......................................................................................................37LED Klasse ..................................................................................................37Lesefeldkurve...............................................................................................47Numerische Tabelle .....................................................................................48INDICEServicios Disponibles en Nuestras Web Site................................................39Descripción y Utilización...............................................................................40Carga y Instalación de la Batería..................................................................41Configuración del Gryphon™ .......................................................................42Gryphon™ - Configuración Predefinida........................................................44Características Técnicas ..............................................................................45Garantia .......................................................................................................46Advertencias ................................................................................................46Clase de LED...............................................................................................46Curva de Respuesta Óptica .........................................................................47Tabla Numérica............................................................................................48
GRYPHON™M SERIES READERSQuick Reference
English2SERVICES AVAILABLE AT OUR WEB SITE:By completing the electronic form at our website,www.datalogic.com/hhd/gryphon_utilities.htm, you have free access todownload the following items:• WinSetPlus™WinSetPlus™ is a Windows-based utility program which allows deviceconfiguration using a PC. It provides RS232 interface configuration aswell as configuration barcode printing.• Loader:The Loader utility program is necessary to load the application software(upgrades) onto your reader.• Software Upgrades:Future software upgrades allow your reader to be updated with thelatest improvements.These items are also available from your local Datalogic distributor.
English3USING GRYPHON™ READERSThe Gryphon™ M series reader, paired with an OM-GRYPHON cradle, buildsa Cordless Reading System for the collection, decoding and transmission ofbarcoded data.GRYPHON™ readers automatically scan barcodes at a distance. Simply aimand pull the trigger. Code scanning is performed along the center of the lightbar emitted from the reading window. This bar must cover the entire code.READING ANGLESuccessful scanning is obtained by tilting the reader with respect to thebarcode to avoid direct reflections which impair the reading performance, seethe figure below.Successful reading is obtained by an audible tone plus a good-read greenspot.OK Not AdvisedTo start using your Gryphon™ reading system you must:1.  Connect an OM-GRYPHON cradle to the Host. For installation andconnection information see the OM-GRYPHON Quick Reference Manual.2.  Charge the Gryphon™ battery using an OM-GRYPHON / C-GRYPHONcharger as described in this Quick Reference manual. A full charge takes3 hours with NiMh battery models.3.  Configure the reader as described in this Quick Reference manual.4.  Configure the OM-GRYPHON cradle. See OM-GRYPHON Configuration inthe “OM-GRYPHON Quick Reference manual”.Good read spotGood read LED
English4CHARGING THE BATTERIESOnce the OM-GRYPHON is connected and powered, the yellow LED goeson, then you can charge the reader’s batteries.Place the Gryphon™ into the OM-GRYPHON cradle. The red charging LEDon the cradle goes on.The battery is completely charged when the green LED on the cradle goes on(see below).After many recharging cycles NiMh and NiCd batteries may tend to lose theiroperating autonomy. This condition can be overcome by inserting theGryphon™ into the OM-GRYPHON / C- GRYPHON charger and pressing the“battery reconditioning” button.Power on / Data(yellow LED)Battery reconditioningbuttonCharging(red LED)Charge completed(green LED)
English5When the above procedure is no longer effective, the batteries must bechanged. To change the batteries of your reader, unscrew the battery coverscrew, replace the old batteries with new ones, then insert the cover in thehandle and screw it back into place. (See the following figures).CAUTIONRisk of explosion if battery is replaced with an incorrect type.Dispose of the batteries as required by the relevant laws in force.GRYPHON™ CONFIGURATIONWhen the cradle is connected and powered, configure the Gryphon™ byreading the following codes in the given sequence and follow the instructions.Note: for the numeric code selection of step 3, use the table at the end of thisQuick Reference.Restore Gryphon™ default1. iPkiPkiPkEnter configuration2. ikikikSet Radio Address3. i3'ki3'ki3'k+four digits for the Gryphon™ Address(from 0000 to 1999).All readers used in the same area must have different addresses.
English6Exit and Save configuration4. i ki ki k5. Read the Bind code to pair the Gryphon™ to the cradle.The reader is dedicated to the cradle. Any previously bound reader willbe excluded.Bindi3/*ki3/*ki3/*kThe green LED on the Gryphon™ will go on: the reader is ready to beinserted into the cradle.6. Firmly insert the reader into the cradle, a beep will be emitted,signalling that the OM-GRYPHON cradle has been paired to theGryphon™, and the green LED on the reader will go off.YOUR READER IS NOW CONFIGURED TO READ BARCODES USINGTHE DEFAULT VALUES.Configure the OM-GRYPHON cradle, refer to the “OM-GRYPHONQuick Reference”.7.Green LED
English7GRYPHON™ DEFAULT CONFIGURATIONPOWER SAVEscan rate 270 scans/sREADING PARAMETERSoperating mode hand-held, hardware trigger, trigger active level, no timeout,Flash On = 1 sec, Flash Off = .6 sec, one read per cycle, safety time .5 sec,beeper intensity high, tone 2, beeper type monotone, beeper length short,good read spot duration mediumDECODING PARAMETERSink spread enabled, overflow control enabled, interdigit control enabled,Puzzle Solver™ disabled, decoding safety = one readREADER OPERATING PARAMETERScode identifier disabledCODE SELECTIONenabled codesM200 Code PDF417EAN 8/EAN 13 / UPC A/UPC E without ADD ONcheck digit transmitted, no conversionsInterleaved 2/5check digit control and transmission, variable length code;4-99 charactersStandard Code 39no check digit control, variable length code; 1-99 charactersM100M200Code 128disabled codesM100M200EAN 128, ISBT128, Code 93, Codabar, pharmaceuticalcodes, Codablock-A, Codablock-F Standard and EAN, MSI,Plessey, Telepen, Delta IBM, Code 11, Code 16K, Code 49ADVANCED FORMATTING PARAMETERSconcatenation disabled, no advanced formats defined
English8TECHNICAL FEATURESElectrical FeaturesBattery Type 2 AA NiMh* batteries1.2 V – 1400 mAhTime of recharge NiMh 3 hours maxOperating autonomy(typ. continuous reading) 6.000 reads - NiMhIndicators LED, Good Read Spot, BeeperOptical FeaturesSensor CCD solid state (3648 pixels)Max scan rate 270 scans/secReading field see reading diagram (p.47)Max. resolution 0.076 mm, 3 milsPCS minimum 15% (Datalogic Test Chart)Radio Features European Models USA ModelsWorking frequency 433.92 Mhz 910 MHzBit rate 19200 baud 36800 baudEffective Radiated Power <10 mW <1 mWRange (in open air) 30 m. 15 m.RF Modulation FSKMax. number of devices in the samereading area 2000Environmental FeaturesWorking Temperature 0 °C to + 40 °CStorage Temperature(without battery) -20 °C to + 70 °CHumidity 90% non condensingDrop resistance IEC 68-2-32 Test EDProtection class IP30Mechanical FeaturesWeight (with batteries) about 280 g.Dimensions 179 x 81 x 98 mmMaterial ABS and Polycarbonate molded withrubber* It is possible to employ also NiCd or non-chargeable Alkaline AAbatteries.
English9WARRANTYDatalogic warranties this product against defects in workmanship andmaterials, for a period of 24 months from the date of shipment, provided thatthe product is operated under normal and proper conditions.Datalogic has the faculty to repair or replace the product, these provisions donot prolong the original warranty term.The warranty does not apply to any product that has been subject to misuse,accidental damage, unauthorized repair or tampering.PATENTSThis product is licensed under one or more of the following U.S. patents:4,282,425; 4,570,057; 4,766,300; 4,894,523; 5,021,642; 5,038,024;5,081,343; 5,095,197; 5,144,119; 5,144,121; 5,182,441; 5,187,355;5,187,356; 5,218,191; 5,233,172; 5,258,606 and /or 5,288,985This product is covered by one or more of the following patents and patentapplications:US 5,917,176; US 5,992,740; US 6,010,073;US pat. Appl. 99US-320.643; US pat. Appl. 99US-362.988;US pat. Appl. 98US-126.606; EP pat. Appl. 00EP-830.127;EP pat. Appl. 00EP-830.122; EP pat. Appl. 98EP-830.336;EP pat. Appl. 98EP-830.611; EP pat. Appl. 97EP-200.317;EP pat. Appl. 97EP-830.408; EP pat. Appl. 96EP-830.473;EP pat. Appl. 96EP-830.660; EP pat. Appl. 96EP-830.439
English10INFORMATION TO THE USERSThis device must be opened by qualified personnel only.The batteries must be removed before opening the device.Modifications or changes to this equipment without theexpressed written approval of Datalogic could void the authorityto use the equipment.This device complies with PART 15 of the FCC Rules. Operationis subject to the following two conditions: (1) This device maynot cause harmful interference, and (2) this device must acceptany interference received, including interference which maycause undesired operation.This equipment has been tested and found to comply with the limits for aClass B digital device, pursuant to part 15 of the FCC Rules. These limits aredesigned to provide reasonable protection against harmful interference in aresidential installation. This equipment generates, uses and can radiate radiofrequency energy and, if not installed and used in accordance with theinstructions, may cause harmful interference to radio communications.However, there is no guarantee that interference will not occur in a particularinstallation. If this equipment does cause harmful interference to radio ortelevision reception, which can be determined by turning the equipment offand on, the user is encouraged to try to correct the interference by one ormore of the following measures:- Reorient or relocate the receiving antenna.- Increase the separation between the equipment and receiver.- Connect the equipment into an outlet on a circuit different from that towhich the receiver is connected.- Consult the dealer or an experienced radio/TV technician for help.Contact the competent authority responsible for the management of radiofrequency devices of your country to verify the eventual necessity of a userlicense.Refer to the web site http://europa.eu.int/comm/enterprise/rtte/spectr.htm forfurther information.LED CLASSCLASS1 LEDEN60825-1/LED11 1996