Datamars LABMAXIII RFID Stationary Reader for Animal Identification User Manual LabMaxIII

Datamars SA RFID Stationary Reader for Animal Identification LabMaxIII

User Manual

   1     LAB MAX III User Manual Version 0.0
 UM00xxxx _LAB MAX III_ User Manual – v. 0.0 March 2012 _Draft    2 Contents: 1 DESCRIPTION ................................................................................................................................ 4 1.1 GENERAL DESCRIPTION ............................................................................................................... 4 1.2 FRONT OVERVIEW ....................................................................................................................... 4 1.3 CONNECTION .............................................................................................................................. 4 2 USER INTERFACE .......................................................................................................................... 5 2.1 KEYPAD ...................................................................................................................................... 5 2.2 ON BUTTON ................................................................................................................................ 5 2.2.1 Power ON the reader ......................................................................................................... 5 2.2.2 Turn OFF the reader .......................................................................................................... 7 2.3 READ A TRANSPONDER ................................................................................................................ 7 2.3.1 Interrupt a reading session ................................................................................................ 8 3 MANAGING THE MENU .................................................................................................................. 9 3.1 FIND YOUR WAY IN THE MENU ....................................................................................................... 9 3.1.1 Parameters ........................................................................................................................ 9 3.2 RFID ........................................................................................................................................ 10 3.2.1 Reading Timeout ............................................................................................................. 10 3.2.2 AID Format ...................................................................................................................... 11 3.2.3 No Display ....................................................................................................................... 12 3.2.4 FDX-B .............................................................................................................................. 12 3.3 SETUP ...................................................................................................................................... 13 3.3.1 Startup file ....................................................................................................................... 13 3.3.2 Update loader .................................................................................................................. 14 3.3.3 Bluetooth ......................................................................................................................... 15 3.3.4 USB VCP ......................................................................................................................... 16 3.3.5 DIAG LVL ........................................................................................................................ 16 3.3.6 DIAG SRC ....................................................................................................................... 17 3.3.7 Send reading ................................................................................................................... 17 3.3.8 Auto Shutdown ................................................................................................................ 18 3.4 INFO ......................................................................................................................................... 18 3.5 LANGUAGE................................................................................................................................ 18 3.6 DATE & TIME ............................................................................................................................ 19 3.6.1 Format ............................................................................................................................. 19 3.6.2 Set date ........................................................................................................................... 19 3.6.3 Set time ........................................................................................................................... 20 3.7 DISPLAY ................................................................................................................................... 20 3.7.1 Timeout backlight ............................................................................................................ 20 3.7.2 Display brightness ........................................................................................................... 21 3.7.3 Start-up image ................................................................................................................. 21 3.8 AUDIO ...................................................................................................................................... 21 3.8.1 Audio level ....................................................................................................................... 22 3.8.2 Keyboard sound .............................................................................................................. 22 3.8.3 Start-up sound ................................................................................................................. 22 3.8.4 Shutdown sound .............................................................................................................. 23 3.8.5 Reading Sound ................................................................................................................ 23 3.9 TEST ........................................................................................................................................ 23 3.9.1 Autotuning RFID .............................................................................................................. 24 3.9.2 Read Cycle ...................................................................................................................... 24 3.9.3 Cyclic Test ....................................................................................................................... 24 3.9.4 Statistic Test .................................................................................................................... 25 4 CONTROL ...................................................................................................................................... 26 4.1 SHUTDOWN .............................................................................................................................. 26 4.2 RECORDING .............................................................................................................................. 27 4.2.1 Recording Stopped .......................................................................................................... 27 4.2.2 Recording Started ............................................................................................................ 27 4.3 BLUETOOTH .............................................................................................................................. 28
 UM00xxxx _LAB MAX III_ User Manual – v. 0.0 March 2012 _Draft    3 4.3.1 Bluetooth Disabled .......................................................................................................... 28 4.3.2 Bluetooth Enabled ........................................................................................................... 28 4.4 PC COMMUNICATION ................................................................................................................. 29 4.4.1 Mass Storage Mode ........................................................................................................ 29 4.4.2 Serial USB Mode ............................................................................................................. 29 4.5 AUDIO LEVEL ............................................................................................................................ 30 4.5.1 Audio Off .......................................................................................................................... 30 4.5.2 Audio On .......................................................................................................................... 30 4.6 BRIGHTNESS LEVEL .................................................................................................................. 31 4.6.1 Brightness High ............................................................................................................... 31 4.6.2 Brightness Mid ................................................................................................................. 31 4.6.3 Brightness Low ................................................................................................................ 31 5 CONNECTORS ............................................................................................................................. 32 5.1 POWER SUPPLY INPUT .............................................................................................................. 32 5.2 USB INTERFACE ....................................................................................................................... 32 6 COMMAND INTERFACE ............................................................................................................... 33 6.1 COMMAND OVERVIEW ................................................................................................................ 33 6.2 COMMAND DESCRIPTION ............................................................................................................ 34 6.2.1 Command: .v ................................................................................................................... 34 6.2.2 Command: .n ................................................................................................................... 34 6.2.3 Command: .i .................................................................................................................... 34 6.2.4 Command: .isNNNN ........................................................................................................ 34 6.3 NEW COMMANDS ....................................................................................................................... 34 6.3.1 Command: .T (only for debug mode) .............................................................................. 34 6.3.2 Command: .ATNG ........................................................................................................... 35 6.3.3 Command: .DTNG (only for debug mode) ...................................................................... 35 6.3.4 Command: .SDATE ......................................................................................................... 35 6.3.5 Command: .STIME .......................................................................................................... 35 6.3.6 Command: .GDATE ......................................................................................................... 35 6.3.7 Command: .GTIME .......................................................................................................... 35 6.3.8 Command: .BLUD ........................................................................................................... 35 7 TAKE CARE OF YOUR READER ................................................................................................. 36 8 SPECIFICATION ........................................................................................................................... 37 9 INFORMATION TO USER ............................................................................................................. 38 10 DO YOU HAVE A PROBLEM IDENTIFYING AN ANIMAL? ......................................................... 39 10.1 THE READING DISTANCE IS TOO SHORT ................................................................................... 39 10.2 THE READER DOES NOT READ THE TRANSPONDER ................................................................... 39 10.3 THE READER DOES NOT WORK................................................................................................ 39 11 ADVANCED USER INSTRUCTIONS ............................................................................................ 40 11.1 CONSOLE COMMANDS DESCRIPTION ....................................................................................... 40 11.1.1 Get firmware version command ...................................................................................... 40 12 CERTIFICATIONS ......................................................................................................................... 41 13 END OF LIFE ................................................................................................................................. 42
 UM00xxxx _LAB MAX III_ User Manual – v. 0.0 March 2012 _Draft    4 1  Description 1.1  General description The LAB MAX III is a RF-ID reader designed to identify animal in laboratory.  For this reason it is recommended to use the reader in an indoor environment.  It reads only ISO FDX-B transponder in accordance to ISO Standard 11784/5.  It allows fast and efficient reading of any animal which has been given an electronic ID device. 1.2  Front overview   Figure 1.2.1 1.3  Connection   Figure 1.3.1  USB Power Supply Casing Keypad Sticker Antenna Display Power Supply USB
 UM00xxxx _LAB MAX III_ User Manual – v. 0.0 March 2012 _Draft    5 2  User interface 2.1  Keypad   Figure 2.1.1  2.2  ON button 2.2.1  Power ON the reader The   button has to be pressed in order to switch on the reader. The display shows the following start-up picture:                     (0.8) 0.6.4  Figure 2.2.1  Under the Datamars logo, you can see the firmware version and the bootloader version in brackets.ON button SELECT LEFT button SELECT RIGHT button ON button
 UM00xxxx _LAB MAX III_ User Manual – v. 0.0 March 2012 _Draft    6 After a few seconds the main screen shot appears:         Figure 2.2.2  1.  The Recording indicator shows if the reader is saving output on file or not. 2.  The USB communication indicator shows if the reader is set on Mass Storage Mode or in Virtual COM Port. 3.  Bluetooth indicator: Bluetooth is optional.   = Bluetooth module on,   = Bluetooth connection established and ready to use. 4.  Date format can be selected between EU/US/TIMESTAMP. 5.  Clock time is in 24 hour mode. 6.  Press   to enter in the main menu of reader 7.  Press   to start a reading session 8.  Press   to enter in the settings menu of reader   5. Clock 4. Date 3. Bluetooth indicator 2.USB communication indicator 1.Recording indicator
 UM00xxxx _LAB MAX III_ User Manual – v. 0.0 March 2012 _Draft    7 2.2.2  Turn OFF the reader After a period of non-use the device goes automatically in “pause mode”, which means the backlight of the display turns down, the screen is “frozen” and the keyboard is disabled. In order to “unlock” your reader, please press the   button. In  order  to  manually  switch  off  the  reader,  keep  pushing  the    button  for  about  2  seconds  or select the Shutdown function in the main menu. The reader has also an automatic shutdown function activated after a period of non-use.  2.3  Read a transponder In order to start with a reading session you must be sure that the LAB MAX III reader is turned on, if not you should proceed with the step 2.2.1. The    button  has  to  be  pressed  in  order  to  start  with  the  reading  session,  as  shown  in  the following picture:   Figure 2.3.1  Place the animal over the reader and wait for the reading result, which can have followings results:    Successful read, as shown in Figure 2.3.2:   Figure 2.3.2 2. Country Code 1. Transponder type + Field bit info  3. ID Code
 UM00xxxx _LAB MAX III_ User Manual – v. 0.0 March 2012 _Draft    8 a. When  the  reader  displays  the  word  “Industry”  as  transponder  type,  it  means  that  this transponder is not coded for animals. b.  The Alpha country code is according to ISO 3166, ISO 11784/5. c.  The Identity Code number is according to ISO 11784/5.    Unsuccessful read, as shown in the following picture:   Figure 2.3.3  After  a  while  the  reading  mode  times  out.  The  reader  stops  and  shows  the  message  “TAG  NOT FOUND”. This time can be set by the user in the reader menu. 2.3.1  Interrupt a reading session The ON button has to be pressed in order to stop a reading session, this operation is possible to make in any time of a reading session.
 UM00xxxx _LAB MAX III_ User Manual – v. 0.0 March 2012 _Draft    9 3  Managing the menu 3.1  Find your way in the menu Switch on the reader by pressing the   button, please refer to chapter 2.2.1. In order to open the main menu press SELECT LEFT button on the keypad, as shown in the following picture:  The display shows the following figure:   Figure 3.1.1  You can scroll through the menu by pressing the SELECT LEFT button. In order to enter a sub menu, you have to press the   button while it is highlighted. In order to exit the main menu and return in initial state of reader you have to press the SELECT RIGHT.  3.1.1  Parameters The   button is used to select and confirm the changes made through the parameters. While the parameter is selected you must press the   button for more than 2 seconds to cancel the change and go back into the main menu. The SELECT LEFT and the SELECT RIGHT buttons are used for change the parameter value, as shown in followings pictures:           Figure 3.1.2                Figure 3.1.3
 UM00xxxx _LAB MAX III_ User Manual – v. 0.0 March 2012 _Draft   10 3.2  RFID The RFID menu allows you to manage the configuration.   Figure 3.2.1  3.2.1  Reading Timeout The  Reading  timeout  feature  defines  the  maximum  period  while  the  reader  has  to  stay  in  reading mode.   Figure 3.2.2
 UM00xxxx _LAB MAX III_ User Manual – v. 0.0 March 2012 _Draft   11 3.2.2  AID Format The  AID  format  menu  defines  how  to  show  on  the  display,  and  over  Bluetooth,  the  transponder information.   Figure 3.2.3  It allows six different AID download formats to be defined:   ISO Long (default): -  Animal:  "A0000000964000000123456"  (23 char) -  Industrial:  "R00060000000000123456"  (21 char)   ISO Short: -  Animal:  "964 000000123456"  (16 char) - Industrial:  "0006 0000000000123456"  (21 char)   ISO Tiris (Texas Instruments): -  Animal:  "A 00000 0 964 000000123456”  (26 char) -  Industrial:  "R 0006 0000000000123456”  (23 char)   F-210: -  Animal:  "A 00000 0 0999 000000123456"  (27 char) -  Industrial:  "R 0006 0000000000123456"  (23 char)   BDN-Ita: -  Animal:  "10000000964000000123456”  (23 char) -  Industrial:  "R00060000000000123456"  (21 char)   ISO Short South America (SA): -  Animal:  "964000000123456"  (15 char) -  Industrial:  "0006 0000000000123456"  (21 char)
 UM00xxxx _LAB MAX III_ User Manual – v. 0.0 March 2012 _Draft   12 3.2.3  No Display The  No  Display  feature  allows  choosing  if  the  Display  will  shutdown  while  reading  or  not  (default setting).   Figure 3.2.4  3.2.4  FDX-B The FDX-B feature allows enabling or disabling the FDX-B tags.   Figure 3.2.5
 UM00xxxx _LAB MAX III_ User Manual – v. 0.0 March 2012 _Draft   13 3.3  Setup The Setup menu allows you to manage all the configuration options of the reader.    Figure 3.3.1  There are various features in  the ‘setup’ menu. You can scroll through the features by pressing the SELECT LEFT button.  3.3.1  Startup file The Startup file feature allows choosing if the reader will save data on file when it is switched on. The recording indicator shows this setting.   Figure 3.3.2
 UM00xxxx _LAB MAX III_ User Manual – v. 0.0 March 2012 _Draft   14 3.3.2  Update loader This feature allows uploading the bootloader in the reader. A valid bootloader image must be downloaded in the reader, using the following procedure:  a)  Shutdown the reader and connect it to the PC , using the USB cable. b)  Open Computer and select the LAB MAX III (typically E:), as shown in Figure 3.3.3.   Figure 3.3.3  c) Open the folder “sys” and insert the file IAPLabMaxIII.bin, as shown in Figure 3.3.4.   Figure 3.3.4  d)  Disconnect the reader from the PC.
 UM00xxxx _LAB MAX III_ User Manual – v. 0.0 March 2012 _Draft   15 e)  Wait until the reader restart and go in Setup menu, then choose Update loader as shown in the following picture.    Figure 3.3.5  f)  If the update has been successfully executed the reader sends a firmware update audio signal and makes a shutdown, otherwise it makes an error short sound.  g)  Press the   button to start the reader. h)  In case of error, restart from step a), since no valid file has been found by the reader to start the firmware update.  3.3.3  Bluetooth This feature allows switching on or off the Bluetooth communication.   Figure 3.3.6
 UM00xxxx _LAB MAX III_ User Manual – v. 0.0 March 2012 _Draft   16 3.3.4  USB VCP This feature allows choosing the Mass Storage or Virtual Com Port. The first has to be selected when we want to use the reader like a normal storage support. The second allows exchanging data to the PC using program like Hyperterminal.   Figure 3.3.7 3.3.5  DIAG LVL This feature allows choosing which level of tracing we want to send in output. There are four levels and higher levels enable also lower levels: 1.  DEBUG  all firmware tracing 2.  INFO  diagnostic information like battery level,  Operating  System status or statistic test outputs 3.  ERROR  hardware and firmware errors 4.  NONE  no tracing only reading   Figure 3.3.8
 UM00xxxx _LAB MAX III_ User Manual – v. 0.0 March 2012 _Draft   17 3.3.6  DIAG SRC This feature allows choosing where we want to send the output. There are four choices: 1.  FILE  the device save the output in an internal file. 2.  USB  the device communicate its outputs via USB. 3. BT  the device communicate its outputs via Bluetooth. 4.  ALL  the device uses all the previous output features together.   Figure 3.3.9  3.3.7  Send reading This feature allows choosing  There are two choices: 1.  EIC 2.  None   Figure 3.3.10
 UM00xxxx _LAB MAX III_ User Manual – v. 0.0 March 2012 _Draft   18 3.3.8  Auto Shutdown The Auto Shutdown feature defines the maximum period that the reader stays on while no buttons are pressed. After this period the reader automatically switches off.   Figure 3.3.11  3.4  Info This menu only gives information about the version of the Bootloader and the Firmware on the reader.   Figure 3.4.1  3.5  Language This menu allows you to select the language on your device.            Figure 3.5.1                 Figure 3.5.2
 UM00xxxx _LAB MAX III_ User Manual – v. 0.0 March 2012 _Draft   19 3.6  Date & Time The Data Time menu allows changing settings about the current data and time.   Figure 3.6.1  3.6.1  Format This menu allows you to adjust the date and time including the date format (EU format if you prefer to have the day before the  month, US format if  you prefer to have the month before the day and  the TIMESTAMP format).   Figure 3.6.2  3.6.2  Set date To set the date, select SET DATE and insert the current date.   Figure 3.6.3
 UM00xxxx _LAB MAX III_ User Manual – v. 0.0 March 2012 _Draft   20 3.6.3  Set time To set the clock, select SET TIME and insert the current time.   Figure 3.6.4  3.7  Display The Display menu allows managing all visual features.   Figure 3.7.1  3.7.1  Timeout backlight The Timeout backlight feature allows you to decide how many seconds the display has to stay on.   Figure 3.7.2
 UM00xxxx _LAB MAX III_ User Manual – v. 0.0 March 2012 _Draft   21 3.7.2  Display brightness The Display brightness feature defines the level of the brightness of the display.   Figure 3.7.3  3.7.3  Start-up image The Start-up image feature defines whether or not to display the image while the reader is switching on. When the feature is OFF, the image is disabled. When it is ON, the image is enabled.   Figure 3.7.4  3.8  Audio The Audio menu allows changing sound’s features.   Figure 3.8.1
 UM00xxxx _LAB MAX III_ User Manual – v. 0.0 March 2012 _Draft   22 3.8.1  Audio level The Audio Level feature defines the volume of the sounds of the device and allows you to disable the audio.   Figure 3.8.2  3.8.2  Keyboard sound The Keyboard sound feature enables or disables the acoustic signal when a button is pressed. When the key feature is OFF, the sound is disabled. When it is ON, the sound is enabled.   Figure 3.8.3  3.8.3  Start-up sound The Start-up sound feature enables or disables the acoustic signal when the reader is switched on. When the feature is OFF, the sound is disabled. When it is ON, the sound is enabled.   Figure 3.8.4
 UM00xxxx _LAB MAX III_ User Manual – v. 0.0 March 2012 _Draft   23 3.8.4  Shutdown sound The Shutdown sound feature enables or disables the acoustic signal when  the device is turned off. When the feature is OFF, the sound is disabled. When it is ON, the sound is enabled.   Figure 3.8.5 3.8.5  Reading Sound The  Reading sound  feature  enables or disables the  acoustic signal when  a tag  is found/not found. When the key feature is OFF, the sound is disabled. When it is ON, the sound is enabled.   Figure 3.8.6  3.9  Test The Test unit feature allows you to test your device.   Figure 3.9.1
 UM00xxxx _LAB MAX III_ User Manual – v. 0.0 March 2012 _Draft   24 3.9.1  Autotuning RFID The Autotuning RFID test shows the values of tuning position and power.            Figure 3.9.2              Figure 3.9.3  3.9.2 Read Cycle This feature allows changing the time of one cycle of reading. Note that it has to be higher than the Read timeout set in RFID menu.   Figure 3.9.4  3.9.3  Cyclic Test This feature starts the reading cyclic test.  The cycle is composed by two parts: 1.  A reading time of the amount of seconds set in the Read timeout in RFID menu  2.  A pause time of the amount of time set in Read Cycle minus the reading time.   Figure 3.9.5
 UM00xxxx _LAB MAX III_ User Manual – v. 0.0 March 2012 _Draft   25  3.9.4  Statistic Test This feature starts the reading test of a standard time and visualizes the percentage of reading done of all the tags.   Figure 3.9.6  The final result of a Statistic Test looks like:   Figure 3.9.7
 UM00xxxx _LAB MAX III_ User Manual – v. 0.0 March 2012 _Draft   26 4  Control  The control menu allows enabling various features like Recording mode or Bluetooth communication.   Figure 3.9.1  4.1  Shutdown The Shutdown feature allows shutting down the reader.   Figure 4.1.1
 UM00xxxx _LAB MAX III_ User Manual – v. 0.0 March 2012 _Draft   27 4.2  Recording This feature allows recording data on file.  4.2.1  Recording Stopped If we choose the Recording Stopped feature, the reader stops saving data on the file.   Figure 4.2.1  4.2.2  Recording Started If we choose the Recording Started feature, the reader start saving data on the file.   Figure 4.2.2
 UM00xxxx _LAB MAX III_ User Manual – v. 0.0 March 2012 _Draft   28 4.3  Bluetooth The Bluetooth feature enables or disables the Bluetooth communication.  4.3.1  Bluetooth Disabled If we choose the Bluetooth Disabled feature, the reader stops the Bluetooth communication.   Figure 4.3.1  4.3.2  Bluetooth Enabled If we choose the Bluetooth Enabled feature, the reader starts the Bluetooth communication.   Figure 4.3.2
 UM00xxxx _LAB MAX III_ User Manual – v. 0.0 March 2012 _Draft   29 4.4  PC communication This feature defines how the reader communicates with the computer via USB.  4.4.1  Mass Storage Mode This feature enables the reader to be used like a mass storage memory.   Figure 4.4.1  4.4.2  Serial USB Mode This feature enables the serial communication through the reader and the computer.   Figure 4.4.2
 UM00xxxx _LAB MAX III_ User Manual – v. 0.0 March 2012 _Draft   30 4.5  Audio Level The Audio Level feature defines the volume of the sounds of the device.  4.5.1  Audio Off This feature allows switching off the audio of the reader.   Figure 4.5.1  4.5.2  Audio On This feature enables the audio of the reader.   Figure 4.5.2
 UM00xxxx _LAB MAX III_ User Manual – v. 0.0 March 2012 _Draft   31 4.6  Brightness Level The Brightness Level feature defines the darkness of the video on the device.  4.6.1  Brightness High This feature sets the Brightness Level to the highest value.   Figure 4.6.1  4.6.2  Brightness Mid This feature sets the Brightness Level to the average value. The video becomes darker.   Figure 4.6.2  4.6.3  Brightness Low This feature sets the Brightness Level to the lowest value.   Figure 4.6.3
 UM00xxxx _LAB MAX III_ User Manual – v. 0.0 March 2012 _Draft   32 5  Connectors 5.1  Power Supply Input The LAB MAX III has to be connected to the Power Switching Adapter in order to supply the reader. The  power  supply  is  a  switching  unit  used  by  laptop  computers  and  is  compatible  with  the  power source worldwide, and the output power is 12VDC with 2A.  Power supply: 100-240VAC/0.5A/47-63Hz 12 VDC 2 A. The power supply has the earth connected to the GND. On the Jack connector the positive (plus) is at the center pin.   Figure 5.1.1  5.2  USB interface The reader is provided with an USB cable in order to connect it to the PC as Mass Storage Device or via Virtual COM Port as explained in next chapter.
 UM00xxxx _LAB MAX III_ User Manual – v. 0.0 March 2012 _Draft   33 6  Command interface 6.1  Command overview LAB MAX III is controlled through a serial interface, configured as following:  -  Baud rate: 9600, 14400, 38400, 57600, 115200 (default). -  Data: 8 bit -  Parity: none -  Stop: 1 bit -  Flow control: none  TeraTerm VT or HyperTerminal are examples of available PC software that allow to setup and control the reader LAB MAX III.  Connect a PC running HyperTerminal to the LAB MAX III, setup the serial port and turn on the LAB MAX III. The following output is displayed:  DATAMARS S.A. LabMaxIII firmware version: (x.x) x.x.x  The following table summarizes the LAB MAX III commands which were present in the old version of the reader:  CMD Description Old commands Parameter .v Get reader version  .n Get noise level  .i Get unit Serial Number  .isNNNN Set unit Serial Number   The following table summarizes the new LAB MAX III commands:  CMD Description New commands Parameter .T Save FDXB acquired signal  .ATNG Start antenna autotuning  .DTNG Start/Stop debugging antenna tuning level  .SDATE Set Date using format dd/mm/yyyy dd/mm/yyyy .STIME Set Time using format hh:mm:ss hh:mm:ss .GDATE Get Date using format dd/mm/yyyy  .GTIME Get Time using format hh:mm:ss  .BLUD Reserved   An online command short description can be displayed typing the ‘?’ on the keyboard:  -------------------------------- Command Line Help ------------------------------- .v      Get reader version .n      Get noise level .i      Get unit Serial Number .isNNNN    Set unit Serial Number --------------------------------------------------------------------------------------------- -------------------------------- New Commands ------------------------------------- .T      Save FDXB acquired signal .ATNG      Start antenna autotuning .DTNG      Start/Stop debugging antenna tuning level .SDATE    Set Date using format dd/mm/yyyy .STIME     Set Time using format hh:mm:ss .GDATE    Get Date using format dd/mm/yyyy .GTIME     Get Time using format hh:mm:ss .BLUD      Reserved ----------------------------------------------------------------------------------------------
 UM00xxxx _LAB MAX III_ User Manual – v. 0.0 March 2012 _Draft   34 6.2  Command description The back compatibility commands are identical for the LabMaxII and the LAB MAX III readers. They don’t need any other special character to be executed.  All commands available starts always with a  ‘.’ (DOT) followed by the command name (CMD), and end with a carriage return ([CR] = 13 dec).  .CMD [CR] 6.2.1  Command: .v It returns the firmware version from LAB MAX III, as shown in the following example:  User:      .v LAB MAX III answer:  FW Vx.x.x (Vx.x) 6.2.2  Command: .n It returns the measured noise level. Values of 10 are a bad level end values of 0 are good level, as shown in the following example:  User:      .n LAB MAX III answer:  1 6.2.3  Command: .i It returns the 4 character of the unit Serial Number. If the unit is not equipped with the feature, the message is: "noID", as shown in the following example:  User:      .i LAB MAX III answer:  noID 6.2.4  Command: .isNNNN It  sets  up  the  unit  Serial  Number,  in  order  to  set  this  SN  enter  a  4  digit  number  after  typing  the command. If the code entered is not valid it will be changed to "noID", as shown in following example.  User:      .is4A58 LAB MAX III answer:  noID  Else  User:      .is1234 LAB MAX III answer: 1234  Note that the number will be accepted also if the feature is not installed but the number will be lost at the next power off. 6.3  New commands 6.3.1  Command: .T (only for debug mode) Only for debug mode: it saves FDXB and HDX acquired signal, as shown in following example:  User:      .T LAB MAX III answer:  DC Level: 2051 FDX Noise Floor: 1929740 (2500000) fdxbDC: 2056 fdxbSynch: 17 fdxbHeader: 224 FDXB Done: decoderTAGFOUND Decoding total time: 30
 UM00xxxx _LAB MAX III_ User Manual – v. 0.0 March 2012 _Draft   35 6.3.2  Command: .ATNG It starts the antenna autotuning, as shown in following example:  User:      .ATNG LAB MAX III answer:  Autotuning: 7 : 3087 6.3.3  Command: .DTNG (only for debug mode) It starts/stop the debugging antenna tuning level, as shown in following example:   User:      .DTNG LAB MAX III answer:  Tuning level: 3913 (3856, 385) Tuning level: 3907 (3856, 385) Tuning level: 3920 (3856, 385) Tuning level: 3917 (3856, 385) Tuning level: 3915 (3856, 385) Tuning level: 3908 (3856, 385) User:      .DTNG 6.3.4  Command: .SDATE It set the date using dd/mm/yyyy format, as shown in following example:  User:      .SDATE 31/10/2011 LAB MAX III answer:  Date: 31/10/2011 6.3.5  Command: .STIME It set the time using hh:mm:ss format, as shown in following example:  User:      .STIME 16:40:30 LAB MAX III answer:  Time: 16:40:30 6.3.6  Command: .GDATE It gets the date using the dd/mm/yyyy format, as shown in following example:  User:      .GDATE LAB MAX III answer:  Date:31/10/2011 6.3.7  Command: .GTIME It get the time using the hh:mm:ss format, as shown in following example:  User:      .GTIME LAB MAX III answer:  Time: 10:07:18 6.3.8  Command: .BLUD Command reserved to specialized personnel (service and support and/or repair centers).
 UM00xxxx _LAB MAX III_ User Manual – v. 0.0 March 2012 _Draft   36 7  Take care of your reader  Ensure that the reader does not get damaged. Do not drop it onto a hard surface or subject it to wet conditions.  If the outer casing of the reader becomes soiled, it can be cleaned with a damp cloth. First ensure that it is not connected to the charger.  If for any reason the reader is not working, please do not attempt to repair it, but return it for repair to your local dealer.  The display of the reader LAB MAX III may change color if exposed to temperatures higher than 50°C. It will return to its original color as soon as the temperature gets below 50°C.  At very low temperatures the display may lose its contrast, but at normal temperatures it will return to its normal contrast.
 UM00xxxx _LAB MAX III_ User Manual – v. 0.0 March 2012 _Draft   37 8  Specification    Storage temperature:   -20°C to 65°, 85% RH non condensing  Operating temperature:   -5°C to 55°, 85% RH non condensing   Housing material:   ABS (UL94 HB)   Housing dimension:   340mm (L) x 240mm (W) x 40mm (H)   Housing protection level:  IP--   Power supply:   +12V Switching Power Supply Adapter   Interface to host PC:   USB connection   Transmission frequency:  134.2 kHz   Tag compatibility:   FDX-B   Standards:   ISO 11784/5   Typical reading distance:  xxmm FDX-B: up to 25cm   Certificate:   CE, FCC   Reader weight:   xxxx g
 UM00xxxx _LAB MAX III_ User Manual – v. 0.0 March 2012 _Draft   38 9  Information to user  FCC Part 15  This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.  This equipment has been tested and found to comply with the limits for Class B Digital Device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures.    Reorient or relocate the receiving antenna   Increase the separation between the equipment and receiver   Connect the equipment into an outlet on a circuit different from that to which the receiver is connected   Consult the dealer or an experienced radio/TV technician for help  Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
 UM00xxxx _LAB MAX III_ User Manual – v. 0.0 March 2012 _Draft   39 10  Do you have a problem identifying an animal? 10.1  The reading distance is too short   The maximum reading distance is obtained with the transponder (tag)  perpendicular to the antenna and aimed at the centre of the antenna coil. If the tag is implanted into an animal its orientation may not be optimal and therefore the reading distance may be reduced.  You might be close to a source of electromagnetic disturbances like video or TV. Move a few meters away and try again.  Do not use the reader on a steel table. The metal will reduce the performance of the antenna.  The reading distance is reduced if the transponder is still in the needle.  10.2  The reader does not read the transponder   Change the angle of the reader and try again.  Some  types  of  transponders  from  other  manufacturers  are  disturbed  if  placed  in  the  centre  of  the reader-antenna. It is possible that some tags will not function if placed in parallel and at the centre of the antenna. Change the direction of the tag or of the antenna.  10.3  The reader does not work   Check the ambient temperature: it has to be between -5ºC and +45º C.  If you’re still having problems, please contact your dealer.  The LAB MAX III reader is a product developed and produced by DATAMARS, Switzerland.  Should you have any suggestions or require information regarding this or other DATAMARS products, please contact your dealer.
 UM00xxxx _LAB MAX III_ User Manual – v. 0.0 March 2012 _Draft   40 11 Advanced user instructions 11.1  Console commands description This section is meant to describe the console commands implemented in the LAB MAX III in order to remote control the features and the functions of the reader.  ”answer string” [CR][LF]  11.1.1  Get firmware version command   Command syntax:  “.v” [CR]   Command answer:  ” DATAMARS S.A. LabMaxIII Firmware version: (1.XX) 1.X.X” [CR][LF]   Command action:  none   Parameter range:  none  Description: this command returns the firmware version.
 UM00xxxx _LAB MAX III_ User Manual – v. 0.0 March 2012 _Draft   41 12 Certifications  European directives  Datamars,  Via  ai  Prati,  CH-6930  Bedano  declares,  under  its  own  responsibility,  that  the  product  LAB MAX III is in accordance with the following standards:   ETSI EN 300 330-1 / ETSI EN 300 330-2   Electromagnetic compatibility and Radio spectrum matters (ERM) - Short Range Devices.  ETSI EN 301 489-1 / ETSI EN 301 489-3   Electromagnetic compatibility (EMC) standard for radio equipment and services.  IEC/EN 61000-4-2 / IEC/EN 61000-4-3/ IEC/EN 61000-4-4/ IEC/EN 61000-4-6   Electrostatic discharge, electromagnetic field, electrical fast transient/burst, radio-frequency fields’ immunity.   LAB MAX III satisfies the essential requirements of directives 99/5/EC.
 UM00xxxx _LAB MAX III_ User Manual – v. 0.0 March 2012 _Draft   42 13 End of life  Disassembly Instructions for OMNI MAX reader  Product Name / Model Description OMNI MAX / Any models Universal portable reader  Only  authorized  recyclers  are  permitted  to  use  these  disassembly  instructions.  Any  attempted disassembly  by  a  user  or  unauthorized  party  will  void  the  product  warranty  and  may  irreparably damage the product.  Tools Required  Tool Description Tool Size (if applicable) Nipper Medium Philips screwdriver (0) Small Cutter pliers Medium Hot Air Gun Big
 UM00xxxx _LAB MAX III_ User Manual – v. 0.0 March 2012 _Draft   43 Product Disassembly Process  1   All external plastics have to be removed from the reader (use Philips screwdriver to remove all screws).   The Keypad has to be removed from the top cover casing (use the Hot Air Gun with the cutter pliers in order to easily remove the keypad).   2 Dispose plastic parts of the reader in accordance with local recycling laws.  3 Dispose electronics parts of the reader in accordance with local recycling laws.  4 Dispose cables of the reader in accordance with local recycling laws.

Navigation menu