Deister Electronic APRBHI Inductive Reader User Manual 1

Deister Electronic GmbH Inductive Reader Users Manual 1

Contents

Users Manual 1

HANDHELD
BHT, BHT lite,
BHI, BHI Pro
Manual
- Draft -
V07/06/05
2deister electronic GmbH 30890 Barsinghausen Germany V07/06/05
BiTech Handheld Manual -DRAFT -
© Copyright 2005 by deister electronic GmbH
All rights reserved. No part of this publication may be reproduced, stored in a retrieval
system, or transmitted, in any form or by any means, electronic, mechanical, photocopying,
recording or otherwise, without prior written permission of Agrident GmbH.
Agrident GmbH reserves the right to make changes to any and all parts of this
documentation without obligation to notify any person or entity of such changes.
June 2005 SE/BB
deister electronic GmbH
Hermann-Bahlsen-Str. 11
30890 Barsinghausen
Germany
Telefon:+49 (0) 51 05 - 51 61 11
Telefax: +49 (0) 51 05 - 51 62 17
E-Mail: info@deister-gmbh.de
Web: www.deister.com
V07/06/05 deister electronic GmbH 30890 Barsinghausen Germany 3
BiTech Handheld Manual
-
DRAFT
-
Contents
1 Introduction .....................................................................5
1.1 The 8 keys for the operation....................................................................................... 6
1.2 The status messages in the second line of the DISPLAY ................................................. 6
1.3 The acoustic signals.................................................................................................. 6
2 Operating the BiTech reader ..........................................7
2.1 Power on.................................................................................................................. 7
2.2 Start READ................................................................................................................ 7
2.3 Quick start............................................................................................................... 7
2.4 No ID found............................................................................................................. 8
3 DISPLAY and SAVE of an ID.............................................9
3.1 Standard mode without ACTION CODE..................................................................... 9
3.2 Modus with ACTION CODE ASK ............................................................................... 9
3.3 Modus with ACTION CODE AUTO............................................................................ 9
3.4 Modus with an alphanumeric FORMAT of the ACTION CODE..................................... 9
3.5 Modus with ACTION CODE PLUS function ................................................................. 9
3.6 Modus DISPLAY...................................................................................................... 10
4 The SETUP of the BiTech reader....................................10
4.1 Operation within the menu ...................................................................................... 10
4.2 The OPERATION menu........................................................................................... 10
4.2.1 LAST ID.................................................................................................................. 11
4.2.2 HOTKEY A and HOTKEY B...................................................................................... 11
4.3 The SETUP menu .................................................................................................... 12
4.3.1 RF/ID menu............................................................................................................ 12
4.3.2 BAUDRATE............................................................................................................. 12
4.3.3 DISPLAY................................................................................................................. 12
4.3.4 DISPLAY FORMAT................................................................................................... 13
4.3.5 TIME and DATE ...................................................................................................... 14
4.3.6 VOLUME of Acoustic Signals.................................................................................... 14
4.3.7 POWER MANAGER ................................................................................................ 14
4.3.8 SOFTWARE VERSION ............................................................................................. 14
4.3.9 DEFAULT ............................................................................................................... 14
4.4 The DATA MENU.................................................................................................... 14
4.4.1 MEMORY SPACE.................................................................................................... 15
4.4.2 SHOW DATA ......................................................................................................... 15
4.4.3 SHOW TAG LIST .................................................................................................... 15
4.4.4 USR TAG LIST......................................................................................................... 15
4.4.5 DATA SEND........................................................................................................... 15
4.4.6 LINK LIST SEND...................................................................................................... 15
5 The DEFAULT setting......................................................16
6 Technical Data ...............................................................17
4deister electronic GmbH 30890 Barsinghausen Germany V07/06/05
BiTech Handheld Manual -DRAFT -
V07/06/05 deister electronic GmbH 30890 Barsinghausen Germany 5
BiTech Handheld Manual
-
DRAFT
-
1 Introduction
The portable full-ISO BiTech readers are so small - they fit even into a shirt pocket - they have a
very handy design and are easy to operate even under worse conditions.
The readers are compatible to the ISO standard 11785 and read FDX-B and HDX. Tags with the
widely used chip type H4102 can be read as well.
The two HOTKEYES can be programmed individually and combined with a special action.
Furthermore any read ID could be combined with an ACTION CODE to combine useful information
with the transponder ID.
A look-up table can be downloaded to the reader to show additional information to the transponder
ID.
The BiTech readers have an integrated real-time clock; every ID will be stored with a time stamp.
The large memory is sufficient for 2000 IDs, including time stamp and ACTION CODE.
The large backlit display has 2 x 16 characters and is very readable.
An ergonomic keyboard with 8 keys ensure easy and comfortable operation.
The robust case is IP 54 protected and withstands even harsh environments.
The BiTech reader is prepared for wireless data communication, loading and power supply together
with the BiTech Cradle.
Some of the outstanding features of the BiTech readers are
ACTION CODES
To combine useful information with a transponder ID the BiTech reader offers the ACTION CODES.
They can be a numeric value from 1 to 99 or more comfortable an alphanumeric string of up to 10
digits. The alphanumeric strings have to be loaded into the BiTech reader. The ACTION CODE can
be combined with the ID after reading automatically or can be chosen out of the list with the
SCROLL keys.
ACTION CODE PLUS
As a further enhancement this function allows to add an additional numeric value from 0 to 99 to the
ACTION CODE.
HOTKEYS
A HOTKEY is more than a simple READ button. It could be programmed to do a lot more than a
simple read.
With the HOTKEY you can start a complete sequence of functions by just pressing one button.
As the BiTech readers have two HOTKEYS, you can program them individually for different tasks.
6deister electronic GmbH 30890 Barsinghausen Germany V07/06/05
BiTech Handheld Manual -DRAFT -
Basic operation of BiTech readers
1.1 The 8 keys for the operation
ON/OFF - Switch power on/off
HOTKEY A Starts a READ and or additional functions
HOTKEY B Starts a READ and or additional functions
F – Switch into MENU modus
C – In MENU modus one level up
RETURN Conformation of changes in the MENU modus and one level down
- SCROLL up Move or Value higher
- SCROLL down Move or Value lower
1.2 The status messages in the second line of the DISPLAY
Battery empty, if capacity is as low as 5 to 10%
Memory full!, appears if memory is full
Online modus, if the reader is connected with a PC via cable
Cradle, if the reader is connected with a PC via docking station
RAM ERROR, at failures in memory
1.3 The acoustic signals
One BEEP = keyboard BEEP
4 times BEEP = OK (ID read)
Long BEEP = NOK (no ID read)
High/low BEEP = double read (into one minute)
Keyboard BEEP but longer = ACTION BEEP
V07/06/05 deister electronic GmbH 30890 Barsinghausen Germany 7
BiTech Handheld Manual
-
DRAFT
-
2 Operating the BiTech reader
Before starting operation of the BiTech reader, the batteries being supplied separately have to be
put in the battery case. In case that you would like to use other types of batteries, resp.
rechargeable batteries, please read chapter 4.3.7 POWER MANAGER to set the battery type.
Caution! An other battery type than it is chosen in the selection list of the power manager,
might cause harm to the reader.
2.1 Power on
After the reader is switched on with the ON/OFF key, the DISPLAY can be switched between four
different formats by pressing the keys:
BiTech V. 1.71
<-- 1 2 -->
Software version and ACTION CODE numbers
BiTech V. 1.71
31.01.05 10:14
Date and time
BiTech V. 1.71
Battery OK
Battery condition
BiTech V. 1.71
Data 0/2100
Memory use
2.2 Start READ
After switch on the reader with the ON/OFF key a READ is started with one of the HOTKEYS, any
other action that is connected with the HOTKEY (A or B) will run automatically after reading.
READ HOTKEY A
……….
2.3 Quick start
With the HOTKEY A or B the reader starts directly into the READ modus. After reading, any
other action that is connected with the HOTKEY (A or B) will run automatically.
READ HOTKEY A
……….
8deister electronic GmbH 30890 Barsinghausen Germany V07/06/05
BiTech Handheld Manual -DRAFT -
2.4 No ID found
If there is no transponder in the field of the antenna or no valid ID is received (e.g. a faulty
transponder or too much noise). Display:
NO TRANSPONDER
Action stopped
A new read could be started by pressing HOTKEY A or B.
V07/06/05 deister electronic GmbH 30890 Barsinghausen Germany 9
BiTech Handheld Manual
-
DRAFT
-
3 DISPLAY and SAVE of an ID
3.1 Standard mode without ACTION CODE
The ID will be displayed in the upper line.
In SAVE MODE = ASK, in the second line SAVE? YES/NO will be displayed.
980 123456789012
SAVE? YES
Save with RETURN, reject with “C” or a new reading.
In the AUTO MEMORY MODE the ID will be saved automatically,
980 123456789012
SAVED
The complete content of the data file regarding that transponder could be checked by using the
SCROLL up/down buttons.
3.2 Modus with ACTION CODE ASK
Displays at the second line ACTION CODE = XX.
980 123456789012
AC = XX
The value of AC could be adjusted with the SCROLL KEYS and confirmed with RETURN. The AC
starts with the value chosen under HOTKEY- AC CODE. There set for the preferred AC, a use of
the SCROLL is only needed when another AC is wished.
3.3 Modus with ACTION CODE AUTO
Displays while reading the chosen ACTION CODE (see HOT KEY MENU) and shows after read the
ID:
980 123456789012
Saved
3.4 Modus with an alphanumeric FORMAT of the ACTION CODE
Displays a text of up to 10 digits for the ACTION CODE. The value of AC could be adjusted with the
SRCOLL KEYS and confirmed by RETURN.
980 123456789012
AC = weighing
3.5 Modus with ACTION CODE PLUS function
This function allows combining an ID with a fixed or variable ACTION CODE and an additional
numeric value. ACTION CODE in the HOTKEY MENU can determine the fixed ACTION CODE. The
variable ACTION CODE can be chosen with the SCROLL keys and confirmed by RETURN. The
additional value can also be chosen with the SCROLL buttons from 0 to 99 and then confirmed by
RETURN.
10 deister electronic GmbH 30890 Barsinghausen Germany V07/06/05
BiTech Handheld Manual -DRAFT -
980 123456789012
AC = weighing
980 123456789012
0 Add Value
3.6 Modus DISPLAY
Shows an alphanumeric ALIAS that is connected with the transponder ID in the link list.
XXXXXXXXXX
Saved
4 The SETUP of the BiTech reader
By pressing Key F the handheld changes to the MAIN MENU. The Options of the main menu are:
! SETUP
OPERATION
DATA
SETUP contains all settings for the READER that are valid for both HOTKEYS.
OPERATION has all the functions that could be programmed individually for each HOTKEY.
DATA has all the functions for the handling of data in the memory.
4.1 Operation within the menu
The SCROLL keys are used to move within the MENU structure. The confirmation of the indicated
MENU value with RETURN changes into that SUBMENU. C jumps back to the higher level of the
MENU. F jumps always back to the MAIN MENU.
A changeable value or data is displayed at the second line and can be selected by the SCROLL
keys and confirmed by RETURN. Return to the higher level without change by C.
In case of a YES/NO decision in the second line the value will be confirmed with RETURN and
rejected by C. After the confirmation the APR jumps back to the next higher level of the MENU.
4.2 The OPERATION menu
It has the following submenus
-> LAST ID
HOTKEY A
HOTKEY B
V07/06/05 deister electronic GmbH 30890 Barsinghausen Germany 11
BiTech Handheld Manual
-
DRAFT
-
4.2.1 LAST ID
Shows the last 10 IDs. The IDs could be saved if they are not in the memory yet.
Last ID X/10 S
XXX XXXXXXXXXX
Shows number X out of the last ten. With SCROLL keys move to the searched ID and select the ID
with the ENTER key. The complete data of this ID will be displayed by using the SCROLL keys. S
shows that the ID is saved already. If the ID is not saved yet, pressing ENTER again could save it.
Last ID SAVE
NO
YES
Selection YES/NO with SCROLL buttons and confirmation with ENTER.
4.2.2 HOTKEY A and HOTKEY B
Determine which HOTKEY (A or B) will be programmed. The Submenus are only valid for the
chosen HOTKEY.
HOTKEY has the following options
o MODE
o AC CODE
o SAVE MODE
MODE appoints how the ACTION CODE is combined with the ID number
o No ACTION CODE, no ACTION CODE will be shown or requested.
o AC ASK, after reading an ID, the reader asks for an ACTION CODE that can be
selected by the SCROLL keys and confirmed with ENTER.
o ASSIGN ASK, ALIAS IDs in the link list that are not already linked with an ID, will be
shown. By scrolling up and down one alias can be chosen and confirmed with
ENTER. Then alias and ID are linked until the link list is deleted.
o ASSING ASK SAVE, the assigned link will be saved automatically.
o AC AUTO PLUS, a certain ACTION CODE that is defined at AC CODE (see below)
will be automatically saved with a read ID. After reading the ID with the SCROLL
keys an additional numeric value can be chosen.
o AC ASK PLUS, an ACTION CODE and a numeric value can be linked to the ID
being read.
o AC AUTO, a certain ACTION CODE that is defined at AC CODE (see below) will be
automatically saved with a read ID.
AC CODE, determines an ACTION CODE by SCROLL keys for that HOTKEY. It will be
automatically saved when read an ID.
SAVE MODE determines how a read ID will be saved.
o AUTO saves the ID automatically.
o ASK requires the confirmation of SAVE with YES/NO after read.
12 deister electronic GmbH 30890 Barsinghausen Germany V07/06/05
BiTech Handheld Manual -DRAFT -
4.3 The SETUP menu
Comes with the submenus
-> RF/ID
BAUDRATE
DISPLAY
DISPLAY FORMAT
TIME/DATE
VOLUME
POWER MANAGER
SOFTWARE VERS.
DEFAULT
4.3.1 RF/ID menu
Consist of all functions for reading a transponder.
READ LENGTH
DOUBLE READ
READ LENGHT
Determines how many (xx) seconds the reader tries to read a transponder.
Read Length
= XX Seconds
Choose by SCROLL keys and confirm by RETURN.
DOUBLE READ defines if the same transponder will not be read into a certain time period. The
value for the period can be OFF, 15, 30,45 and 60 seconds.
Choose by SCROLL keys and confirm by RETURN.
4.3.2 BAUDRATE
Consist of the settings of the interface valid values from 9600 to 57600, choose by SCROLL keys
and confirm by RETURN.
4.3.3 DISPLAY
All commands concerning the display are found here.
-> LANGUAGE
POWER OFF
CONTRAST
BRIGHTNESS
LIGHT OPTION
V07/06/05 deister electronic GmbH 30890 Barsinghausen Germany 13
BiTech Handheld Manual
-
DRAFT
-
LANGUAGE (English/Deutsch)
-> ENGLISH
DEUTSCH
Choose by SCROLL keys and confirm by RETURN.
LIGHT OPTION
-> ON AT EXT POWER
OFF AT EXT POWER
If LIGHT is switched ON/OFF when the reader is powered externally.
CONTRAST
-> Contrast = X
Choose from 1 to 5 with SCROLL keys and confirm by RETURN.
BRIGHTNESS as CONTRAST
POWER OFF
-> POWER OFF
XX SECONDS
Choose XX from 3 to 20 by SCROLL keys and confirm by RETURN.
4.3.4 DISPLAY FORMAT
Consist of all commands that determine how a transponder ID is displayed and saved. It has the
following options:
-> VISION FORMAT
AC FORMAT HOT K
ALIAS IF AVAIL
VISION FORMAT determines how the transponder ID is displayed.
ISO Mode STD
ISO Mode STDISO Mode STD
ISO Mode STD animal ISO mode
BDE/HEX Format
BDE/HEX FormatBDE/HEX Format
BDE/HEX Format hexadecimal
transponder ID
HEX Inv. Format
HEX Inv. FormatHEX Inv. Format
HEX Inv. Format hexadecimal
transponder ID, displayed in opposit direction
BiTech Format
BiTech FormatBiTech Format
BiTech Format transponder ID in Bitech mode
Telindus
TelindusTelindus
Telindus transponder ID in Bitech mode (customers application)
Change value by SCROLL confirm by RETURN.
AC FORMAT HOT K determines if the ACTION CODE is displayed as alpha or numeric value.
Alpha works only, if a list of alphanumeric ACTION CODES is loaded into the BiTech reader.
ALIAS IF AVAIL, if set to ON, the alias of the transponder will be displayed instead of the
transponder ID. This works only, if a TAG LIST is loaded into the BiTech reader and an alias for the
read transponder is available.
If set to OFF the transponder ID will always be displayed.
14 deister electronic GmbH 30890 Barsinghausen Germany V07/06/05
BiTech Handheld Manual -DRAFT -
4.3.5 TIME and DATE
Offer different options to set time and date.
-> SET TIME
TIME FORMAT
SET DATE
DATE FORMAT
SET TIME, change value by SCROLL, confirm by RETURN.
TIME FORMAT, could be chosen between 12 or 24 h.
SET DATE, change value by SCROLL, confirm by RETURN.
DATE FORMAT, could be chosen between dd.mm.yy and mm.dd.yy.
4.3.6 VOLUME of Acoustic Signals
Change value 0 to 15 by SCROLL confirm by RETURN.
4.3.7 POWER MANAGER
For the selection of the battery type. AKKU means rechargeable batteries, the capacity determine
the needed power for recharging.
BATTERY
AKKU > 2000 mA
AKKU 1500-2000 mA
AKKU 1000-1500 mA
Change value by SCROLL confirm by RETURN.
4.3.8 SOFTWARE VERSION
Displays the version and date of release of the current software, loader version and the serial
number.
4.3.9 DEFAULT
Sets all values back to factory settings (see 5. default settings)
4.4 The DATA MENU
With the submenus
-> MEMORY SPACE
SHOW DATA
SHOW TAG LIST
USR TAG LIST
DATA SEND
LINKLIST SEND
V07/06/05 deister electronic GmbH 30890 Barsinghausen Germany 15
BiTech Handheld Manual
-
DRAFT
-
4.4.1 MEMORY SPACE
Displays the current use of the memory, with the SCROLL keys also the amount of data in the link
and ACTION CODES list could be displayed.
4.4.2 SHOW DATA
Display the data in the memory. Move with the SCROLL keys through the data. When you choose a
particular data with RETURN it switches into DATA VIEW MODUS.
SHOW DATA ZX
980 123456789012
The complete data can be displayed by scrolling with the SCROLL keys through the lines.
ZX is the number of the data line.
AC is the number of the ACTION CODE.
HDX, FDXB or 4002 are the transponder types HDX, FDX-B or H4002.
4.4.3 SHOW TAG LIST
Displays the transponder ID and the alias, if a link list is loaded into the BiTech reader.
SHOW TAG L X U
ALIAS 1
SHOW TAG L X P
ALIAS 1
X is the number of the alias, U means it is already assigned, P means it is not assigned yet (Free).
4.4.4 USR TAG LIST
Displays the ALIAS already assigned to a transponder ID since the last download of the TAG LIST.
USR TAG LI X U
ALIAS 1
With RETURN chose and open the displayed file. Back with “C”
4.4.5 DATA SEND
Sends the complete content of the data memory to a PC and can be saved with a software like
hyperterminal.
4.4.6 LINK LIST SEND
Sends the content of the link list to a PC, if you already have downloaded one into the BiTech
reader.
16 deister electronic GmbH 30890 Barsinghausen Germany V07/06/05
BiTech Handheld Manual -DRAFT -
5 The DEFAULT setting
The BiTech readers come with the following default setting:
ISO MODE STD
Both HOTKEYS with the same function
o READ = YES
o Confirm SAVE = YES
o AC mode = OFF (Value 0)
o DISPLAY FORMAT = BiTech Format
o Show DISPLAY = 5 seconds
RF/ID - READ LENGTH = 7 seconds
TRANSPONDER = HDX, FDX-B, 4002
DISPLAY = BiTech Format
COUNTRY CODE = Decimal
VOLUME = 5
Language = English
Changes in the setting will be saved automatically. With the DEFAULT function in the SETUP menu
the default settings will be restored.
V07/06/05 deister electronic GmbH 30890 Barsinghausen Germany 17
BiTech Handheld Manual
-
DRAFT
-
6 Technical Data
Frequency 134,2 kHz
Transponder types
HDX compatible (ISO 11784/5)
FDX-B compatible (ISO 11784/5)
H4002 compatible (optional)
Reading range:
Approx. 15 cm with HDX transponder 30 mm
Approx. 10 cm with FDX-B transponder 30 mm
Interfaces
Cradle
Power supply
2 x 1,5V AA mignon batteries
External power supply via cradle
Recharge via cradle
Protection
IP 54
Temperature range
0 to 60°C
Measurements and weight
LxWxH 175x90x36 mm, approx. 350 g
18 deister electronic GmbH 30890 Barsinghausen Germany V07/06/05
BiTech Handheld Manual -DRAFT -
Regulatory notices
Regulatory notices for Europe:
Hereby, deister electronic GmbH declares that this equipment - if used according to the instructions
- is in compliance with the essential requirements and other relevant provisions of the RTTE
Directive 1999/5/ EC.
Zulassungen für Europa:
Hiermit erklärt die deister electronic GmbH, dass sich diese Funkanlage bei bestimmungsgemäßer
Verwendung in Übereinstimmung mit den grundlegenden Anforderungen und den anderen
relevanten Vorschriften der RTTE Richtlinie 1999/5/EG befindet.
! A complete declaration of conformity can be requested at:
" Eine vollständige Konformitätserklärung kann angefordert werden unter:
info@deister-gmbh.de
Regulatory notices for USA:
FCC digital device limitations
Radio and television interference
This equipment has been tested and found to comply with the limits for a digital device, pursuant to
Part 15 of the FCC rules. These limits are designed to provide reasonable protection against
harmful interference when the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference, in which
case the user will be required to correct the interference at his own expense.
This device complies with Part 15 of the FCC rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
CAUTION: Changes or modifications not expressly approved by the party responsible for
compliance could void the user's authority to operate this equipment.
V07/06/05 deister electronic GmbH 30890 Barsinghausen Germany 19
BiTech Handheld Manual
-
DRAFT
-
deister worldwide
Germany:
deister electronic GmbH
Hermann-Bahlsen-Str. 11
30890 Barsinghausen
Tel.: +49 (0) 51 05 - 51 61 11
Fax: +49 (0) 51 05 - 51 62 17
info@deister-gmbh.de
www.deister.com
Great Britain:
deister electronic (UK) Ltd.
Camelgate,
Spalding
Lincolnshire PE12 6ET
Tel.:+44 (0) 1775 - 717100
Fax:+44 (0) 1775 - 717101
info@deister.co.uk
USA:
deister electronic USA Inc.
9303 Grant Avenue
Manassas, VA 22110
Tel.:+1 703 - 368 2739
Fax:+1 703 - 368 9791
info@deister.com
Canada:
deister electronic Inc.
1099 Kingston Road, Suite 212
Pickering ON. L1V 1B5
Tel.:+1 905 - 837 5666
Fax:+1 905 - 837 0777
info@deister-electronic.com
Belgium & Luxemburg:
deister electronic office
Business Park E 19
Battelsesteenweg 455/A
2800 Mechelen
Tel.:+32 (0) 15 - 28 09 68
Fax:+32 (0) 15 - 28 09 71
info@benelux.deister.com
The Netherlands:
deister electronic office
Tolnasingel 3
2411 PV Bodegraven
Tel.:+31 (0) 1726 - 32970
Fax:+31 (0) 1726 - 32971
info@nl.deister.com
France:
deister electronic france
101 rue Pierre Semard
92320 Chatillon
Tel.:+33 (0) 1 47 - 35 78 78
Fax:+33 (0) 1 47 - 35 92 59
info@deister.fr

Navigation menu