Deister Electronic KPD5SWH4200 Inductive Reader User Manual SWH 4200 install guide black

Deister Electronic GmbH Inductive Reader SWH 4200 install guide black

Users Manual

Download: Deister Electronic KPD5SWH4200 Inductive Reader User Manual SWH 4200 install guide black
Mirror Download [FCC.gov]Deister Electronic KPD5SWH4200 Inductive Reader User Manual SWH 4200 install guide black
Document ID514101
Application IDhJcZbJiCwiaMXRk6gAu1sg==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize36.05kB (450624 bits)
Date Submitted2005-02-10 00:00:00
Date Available2005-02-10 00:00:00
Creation Date2004-05-05 13:08:27
Producing SoftwareAcrobat Distiller 5.0.5 (Windows)
Document Lastmod2005-02-07 17:17:27
Document TitleSWH-4200 install guide-black.fm
Document CreatorFrameMaker 7.0
Document Author: lturmel

Model SWH-4200
Contactless Multi-Technology
125 KHz and 13.56 MHz Reader
Installation Guide
Version A0
Part Number UM-090
January 2005
co
CONTENTS
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Installation Considerations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Installation Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Model SWH-4200 Technical Specifications . . . . . . . . . . . . . . . . . . . . . . .11
FCC Digital Device Limitations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
UL Standards Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
CE Marking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
co
INTRODUCTION
The SWH-4200 Contactless reader will read Prox and Smart Cards at
frequencies of both 125 kHz and 13.56 MHz. The reading capability
includes, for Smart Cards, both unencrypted serial numbers and encrypted
programmed sectors. Refer to Table 1 for a complete list of compatible
standards and data.
TABLE 1. Compatible Credential Formats - Model SWH-4200
HID® 26 Bit
ISO 14443A (MIFARE®) Sector
HID® Corporate 1000
ISO 14443B Serial Number
HID® 36 Bit Wiegand
ISO 15693 Serial Number
HID® 37 Bit Wiegand
MIFARE® Sector SmartFrame®
NTNumber
Other HID pass through formats
DESFire E
Serial
ID Serial Number
Deister Prox SmartFrame®
iCLASS®
NOthers - Future Expansion
CASI Prox Lite
FEATURES
„
Universal compatibility with most 125 kHz Prox (including all HID®
Prox formats) and with all ISO 15693 and ISO 14443A credentials
(badges, disk tags and key fobs). Reads both 125 kHz and 13.56 MHz
credentials in the same reader.
„
Electrical protection (reverse polarity diode protection on power lines)
„
Data lines: high-speed transient voltage suppressor diodes
„
IP65-rated sealed electronics for deployment in both interior and
exterior environments
„
Integrated reader tamper protection
co
MOUNTING
Mount the single-gang backplate (with tamper magnet installed) onto the
wall.
FIGURE 1. Model
SWH-4200
Backplate
otamper switchReader
(includes
magnet)
Ty
NOTE
Mounting holes fit standard U.S. single-width electrical box and
standard European (EMEA) electrical box hole patterns.
Mount the reader module directly to the backplate and then snap the front
cover in place as indicated in Figure 2.
O Assembly
FIGURE 2. C
Mounting
(including 1ooptional isolation spacer)
INSTALLATION CONSIDERATIONS
An isolation spacer (available from Software House, part number
SWH-ISOSPC) may be used to improve the read range distance when
mounting the reader to a metal surface. To optimize reader range use the
number of backplates as indicated in Table 2. Use of Isolation Spacers is
optional and not required for non-metal mounting surfaces.
TABLE 2. Isolation spacer recommendation
for mounting the SWH-4200 reader on metal.
Distance
Reading Distance
No metal plate
100%
4.5 cm
100%
2.7 cm (3 tamper plates)
85%
1.8 cm (2 tamper plates)
70%
0.9 cm (1 tamper plate)
50%
0 cm
10%
Installation of two SWH-4200 readers T
side-by-side
and back-to-back
F distance between two
Read range is not affected if the center-to-center
readers is greater than or equal toC
four (4) inches (101.6 mm). Two readers
o badge or tag if the distance between the
can simultaneously read the
same
two readers is less than
T4 inches, center-to-center. If the distance between
the two readers is less than four inches, field interference between the two
readers may result in a double-badge read.
NOTE
If two readers are being placed back-to-back on a wall less
than 4 inches thick, maximum performance can be achieved
by using a metal separation plate and then using isolation
spacers as necessary.
WIRING
The Model SWH-4200 has twelve terminals as noted in Table 3. The
terminal strip is removable for easy installation and wiring. When attaching
wires to the connector, strip off only the minimum insulation required
(approx. 1/8'') and push the wire into the connector until the insulation is
flush or inside the connector body. This is particularly critical for outdoor
readers. While the reader itself is designed and protected to IP65 standards,
the cable wires can potentially corrode and short together if not carefully
mounted and tightly fastened in the connector body.
TABLE 3. Connector Pins for Model SWH-4200
Ground
Power (8 to 16 VDC)
D1 Wiegand
co
D0 Wiegand
Reserved for Future Use
External Green LED Control
External Red LED Control
A - RS485 - used for Flash upgrade
10
B - RS485 - used for Flash upgrade
11
Tamper (Normally Closed)
12
Tamper (Normally Closed)
PIN #
Description
External Beeper Control
Table 4 indicates maximum wiring distances per Wiegand standard with
the three most common gauges of cable.
TABLE 4. Maximum cable distance for 18, 20, or 22 AWG wire
Wire Gauge
18 AWG
20AWG
22 AWG
Cable
Distance
500 feet
(152 meters)
300 feet
(91 meters)
200 feet
(61 meters)
INSTALLATION NOTES
Unless otherwise specified in this document, please follow the guidelines
below:
2. You may use a local power supply for the reader.N
If so, do not connect
the power supply from the controller to the
reader. The ground line of
F to the power supply of the
the local power supply must be connected
controller
The unit needs to be operated
with a power source with limited
power consumption according
co to EN 60950-1 (2003) paragraph 2.5.
T may be required by some controllers. Consult
3. Use of a pull-up resistor
1. Shielded cable is recommended in electrically noisy environments.
your controller manual.
4. For tamper wiring, connect Pins 11 and 12 to a normally closed
supervised input, as shown in Figure 3.
FIGURE 3. Normally Closed Wiring for Reader Tamper
TROUBLESHOOTING
If the operation of a component is in doubt, substitute a known good
component and retry the system. Always verify wiring against the provided
wiring information before powering up the reader.
TABLE 5. Error Conditions and Possible Solutions
Condition
Possible Solutions
None of the LEDs
are on.
Check the following:
„ Power connections to the reader.
„ Reader supply voltage at connector pin 3 and
that the ground connection pin 2 is secure and
well connected.
The door does not
open and the green
LED does not light
when a qualified
credential is
presented.
The green LED
does not light but
the door strike
unlocks the door
when a valid
credential is
presented.
10
Verify that the door strike andN
the green LED are
Ethe access credential
wired correctly. VerifyIthat
Fthat the reader has been
has been entered and
properly configured
O in the host system.
co
TVerify that the door strike is wired correctly. Refer
to the appropriate wiring diagram in your
controller manual.Disconnect the wire from pin 7
(green LED) and connect pin 7 to pin 2 (ground). If
the green LED is now on, the reader is good and
the connection to the reader is defective. If the
green LED does not light, replace the reader.
MODEL SWH-4200 TECHNICAL
SPECIFICATIONS
Cable Recommendations:
4 core (minimum), shielded, 22 AWG
(minimum) cable.
Connectors:
12 position, 3.5 mm Screw Terminals Plug-In
Certifications:
FCC Part 15, CE and UL 294
Open Standards
Compliance:
ISO 14443A
ISO 14443B (Depending on specific
implementation)
ISO 15693 (including some partially
compliant credentials)
Other Standards
Deister SmartFrame®
ID in both 125 kHz and
Compliance:
13.56 MHzF
implementations
N at 125 kHz (All Formats)
HID® Prox
C (other colors available; contact your
Standard Color:
Black
c Software House representative)
Dimensions with backplate 4.37" × 3.31" × 1.10" (110.99 × 84.07 ×
(height/width/depth):
27.94 mm)
Power Supply
8-16 VDC 125 mA maximum current @ 12
VDC
Environments:
Meets UL 294 standards for Outdoor Use.
Humidity:
5 to 100% (non-condensing)
Operating Temperature:
-31º F to 151º F (-35º to 67º C)
11
Index of Protection:
IP 65 (IEC 529)
Read Range:
1 to 5 inches depending on credential
technology and environment.
Note: Read range for credentials of
identical technologies may vary greatly
depending on the tuning and antenna
structure of each individual credential.
Standard Wiegand Output
including:
ID Pass-Through Option
Serial Number Read
Fixed Wiegand bit stream option
SmartFrame® encrypted mifare Sector read
and conversion to Wiegand
Consult your Software House
representative for available reconfiguration
cards for your reader.
F capability using RS485
Upgrade
Complete
upgrade
port O
for reflashing of internal ROM.
RS485 output option
coAvailable for compatible controllers.
12
FCC DIGITAL DEVICE LIMITATIONS
Radio and Television Interference
This equipment has been tested and found to comply with the limits
for a digital device, pursuant to Part 15 of the FCC rules. These limits
are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is
likely to cause harmful interference, in which case the user will be
required to correct the interference at his own expense.
This device complies with Part 15 of the FCC Rules.
ID (1) this device
Operation is subject to the following twoFconditions:
may not cause harmful interference, N
and (2) this device must accept
any interference received, including
interference
that may cause
undesired operation.
co
In order to maintain compliance with FCC regulations, shielded cables
must be used with this equipment. Operation with non-approved
equipment or unshielded cables is likely to result in interference to
radio and television reception.
Caution: Changes or modifications not expressly approved by the
manufacturer could void the user’s authority to operate this
equipment.
13
CANADIAN RADIO EMISSIONS
REQUIREMENTS
This digital apparatus does not exceed the Class A limits for radio noise
emissions from digital apparatus set out in the Radio Interference
Regulations of the Canadian Department of Communications.
Le present appareil numerique n'emet pas de bruits radioelectriques
depassant les limites applicables aux appareils numeriques de la class A
prescrites dans le Reglement sur le brouillage radioelectrique edicte par le
ministere des Communications du Canada.
E Inc. for standard
This reader has been tested by Underwriters Laboratories,
UL 294, Access Control System Units, butF
has not been tested for
compliance with any particular model
Oof controller.
co
UL STANDARDS COMPLIANCE
14
CE MARKING
A Declaration of Conformity exists for the following Software House
Multi-technology readers:
SWH-4100
SWH-2100
SWH-1100
SWH-5100
SWH-4200
SWH-3100
SWH-1000
SWH-3000
SWH-5000
SWH-2000
To obtain a copy, contact Software House and request the “Declaration of
Conformity” document for Multi-technology readers.
Software House
70 Westview Street
Lexington, MA 02421 U.S.A.
In case of alteration of the product, not agreed to by us,
this declaration will
lose its validity.
co
This symbol indicates proof of conformity to
applicable European Economic Community
Council directives and harmonized standards
published in the official journal of the European
Communities.
15
Copyrights and Trademarks
This document contains proprietary information of Tyco International, Inc. and is furnished to its
customer solely to assist in the installation, testing, operation and maintenance of the equipment
described. This document may not be reproduced in whole or in part without the written approval of
Tyco International.
Copyright 2005 Tyco International
All rights reserved.
Printed in Germany.
MIFARE® is a registered trademark of Philips Electronics, N.V.
HID® and iCLASS® are registered trademarks of Assa Abloy AB.
co
Software House
70 Westview Street
Lexington, MA 02421
http://www.swhouse.com
Fax: 781-466-9550 Phone: 781-466-6660
16
#896022

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 16
Page Mode                       : UseOutlines
Has XFA                         : No
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:5e2409e3-4700-4c74-aa28-032ac11a3c87
Producer                        : Acrobat Distiller 5.0.5 (Windows)
Create Date                     : 2004:05:05 13:08:27Z
Modify Date                     : 2005:02:07 17:17:27+01:00
Metadata Date                   : 2005:02:07 17:17:27+01:00
Creator Tool                    : FrameMaker 7.0
Document ID                     : uuid:68b60f49-790c-42c7-9df9-cbc545adcd3f
Format                          : application/pdf
Creator                         : lturmel
Title                           : SWH-4200 install guide-black.fm
Author                          : lturmel
EXIF Metadata provided by EXIF.tools
FCC ID Filing: IXLKPD5SWH4200

Navigation menu