Dell Chassis Management Controller Version 1 30 For Poweredge Vrtx Owners Manual (CMC) 1.30 Release Notes

2014-11-13

: Dell Dell-Chassis-Management-Controller-Version-1-30-For-Poweredge-Vrtx-Owners-Manual-118068 dell-chassis-management-controller-version-1-30-for-poweredge-vrtx-owners-manual-118068 dell pdf

Open the PDF directly: View PDF PDF.
Page Count: 5

DownloadDell Dell-Chassis-Management-Controller-Version-1-30-For-Poweredge-Vrtx-Owners-Manual- Chassis Management Controller (CMC) Version 1.30 For PowerEdge VRTX Release Notes  Dell-chassis-management-controller-version-1-30-for-poweredge-vrtx-owners-manual
Open PDF In BrowserView PDF
Dell Chassis
Management
Controller (CMC)
Version 1.30 for Dell
PowerEdge VRTX
Release Notes

Release Type and Definition
The Dell Chassis Management Controller (CMC) Version 1.30 for Dell PowerEdge VRTX is a System
Management hardware and software solution for managing the Dell PowerEdge VRTX chassis.

Version
1.30

Release Date
March 2014

Previous Version
1.25

Importance
RECOMMENDED: Dell recommends applying this update during your next scheduled update cycle. The
update contains feature enhancements or changes that will help keep your system software current.

Platform(s) Affected
Dell Chassis Management Controller (CMC) for Dell PowerEdge VRTX is supported on the following
system:


PowerEdge VRTX

What is Supported?
License Requirements
The CMC supports software licensing to use advanced systems management features. For more
information about the license requirements, see the Dell Chassis Management Controller for Dell VRTX
User's Guide available at the support site.

Supported Management Station Operating Systems and Web Browsers
for CMC for Dell PowerEdge VRTX


Microsoft Internet Explorer 9 on Windows 7 SP2 32-bit, Windows 7 SP2 64-bit, Windows Server
2008 SP2 32-bit, Windows Server 2008 SP2 64-bit, and Windows Server SP2 2008 R2 64-bit



Microsoft Internet Explorer 10 on Windows 7 SP2 32-bit, Windows 7 SP2 64-bit, Windows 8.1 32bit, Windows 8.1 64-bit, Windows Server 2008 R2 SP2 64-bit, and Windows Server 2012



Microsoft Internet Explorer 8 on Windows 2003 SP2



Mozilla Firefox 22/23 on Windows 7 SP2 32-bit, Windows 7 SP2 64-bit, Windows 8.1 32-bit,
Windows 8.1 64-bit, Macintosh OSX 10.7, Macintosh OSX 10.8, Windows 2003 SP2, Windows
Server 2008 SP2 32-bit, Windows Server 2008 SP2 64-bit, and Windows Server 2012



Google Chrome 27/28 on Windows 8.1 32-bit and Windows 8.1 64-bit



Safari 5.2/6 on Macintosh OSX 10.7 and Macintosh OSX 10.8

Supported Server Modules


Mainboard firmware: 1.30 or later



iDRAC7 Version: 1.55.55 or later



CPLD Version for PowerEdge M520: 1.0.5 or later



CPLD Version for PowerEdge M620: 1.0.6 or later



CPLD Version for PowerEdge M820: 1.0.2 or later



PowerEdge M520 BIOS Version: 2.1.3 or later



PowerEdge M620 BIOS Version: 2.2.7 or later



PowerEdge M820 BIOS Version: 2.0.24 or later

Note: Server modules with unsupported iDRAC7, BIOS, and CPLD versions may turn on in the VRTX
chassis, but can cause some unexpected issues.

What’s New?


Ivy Bridge support for M820



Fault Tolerant (Redundant) PERCs



Support for Windows Server 2012 R2



Support for NVIDIA K2 GPGPU



Broadcom 10GbE quad port NIC



Emulex SeaHawk (FH) PCIe Adapter



Emulex 10G NDC

Fixes
None for this release.

Important Notes


Until the HDDs and PCIe cards are mapped by using the CMC web interface, the shared hard disk
drives (HDDs) and PCIe cards are managed by the CMC and are not visible to the operating
system in the server modules. For instructions about mapping PCIe cards and managing the
storage subsystem, see the Chassis Management Controller for PowerEdge VRTX Version User's
Guide available at the support site.



All the server modules must be turned off before updating the firmware for chassis infrastructure
and SPERC. CMC firmware can be updated while the servers are turned on.



Some advanced features require CMC enterprise license. For more information about the CMC
licenses, see the Chassis Management Controller for PowerEdge VRTX Version User's Guide
available at the support site.



Before updating the storage component using the web interface, make sure that the browser’s
Cookies are enabled.



PERC storage rebuild may take more time when more number of I/O requests are processed, and
could also make CMC and the TTY log to be out of sync for a short period of time.



In fault-tolerant (Redundant) mode, the controller associated with virtual disks or physical disk
drives is the active controller.



Before updating a single PERC, you must turn off the servers before starting the update process.

Known Issues


When you add a member Chassis to a Chassis group using the Multi-Chassis Management
feature, you cannot specify the group members with an IPv6 address.

Limitations
None

Installation
Prerequisites
Before setting up your CMC environment, download the latest version of CMC firmware for PowerEdge
VRTX from the Dell Support Website at dell.com/support/. Also, make sure that you have the Dell
Systems Management Tools and Documentation DVD that is included with your system.

Installation Procedure
1.

In the CMC web interface, click Chassis Overview, and then click Update.

2.

On the Firmware Update page, in the CMC Firmware section, select the required components
under the Update Targets column for the CMC or CMCs (if a standby CMC is present) you want
to update, and then click Apply CMC Update.

3.

In the Firmware Image box, type the path to the firmware image file on the management station
or shared network, or click Browse to browse through to the file location. The default name of
the CMC firmware image file is vrtx_cmc.bin.

4.

Click Begin Firmware Update, and then click Yes. The Firmware Update Progress section
displays information about the firmware update status.

For more information, see the Chassis Management Controller for PowerEdge VRTX Version User's
Guide available at the support site.

Upgrade
For information about version numbers, refer to the "Prerequisites" section. The modules should be
updated in the following order:


Mainboard



SPERC, expanders, and physical disk drives



BIOS



Lifecycle Controller



iDRAC7

NOTE: The CMC firmware should be updated prior to updating the server component firmware modules
listed here.
NOTE: Before updating a single PERC, you must turn off the servers.

Contacting Dell
Note: If you do not have an active Internet connection, you can find contact
information on your purchase invoice, packing slip, bill, or Dell product catalog.
Dell provides several online and telephone-based support and service options.
Availability varies by country and product, and some services may not be available in
your area. To contact Dell for sales, technical support, or customer service issues:
1. Visit www.dell.com/support.
2. Select your support category.
3. Verify your country or region in the Choose a Country/Region drop-down
menu at the top of page.
4. Select the appropriate service or support link based on your need.
For information about documentation support:
1. Go to dell.com/support/manuals
2. In the Tell us about your Dell system section, under No, select Choose from a
list of all Dell products and click Continue.
3. In the Select your product type section, click Software & Security.
4. In the Choose your Dell Software section, click the required link from the
following:
– Client System Management
– Enterprise System Management
– Remote Enterprise System Management
– Serviceability Tools
5. To view the document, click the required product version.
NOTE: You can also directly access the documents using the following links:
o For Client System Management documents —
dell.com/OMConnectionsClient
o For Enterprise System Management documents —
dell.com/openmanagemanuals
o For Remote Enterprise System Management documents —
dell.com/esmmanuals
o For Serviceability Tools documents — dell.com/serviceabilitytools
© 2014 Dell Inc. All rights reserved.
Copyright © 2014 Dell Inc. All rights reserved. This product is protected by U.S. and international copyright and intellectual property laws. Dell and
the Dell logo are trademarks of Dell Inc. in the United States and/or other jurisdictions. All other marks and names mentioned herein may be
trademarks of their respective companies.



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Format                          : application/pdf
Creator                         : Dell Inc.
Title                           : Dell Chassis Management Controller (CMC) Version 1.30 for Dell PowerEdge VRTX Release Notes
Subject                         : Release Notes
Description                     : Release Notes
Producer                        : Acrobat Distiller 10.1.4 (Windows); modified using iTextSharp 5.1.3 (c) 1T3XT BVBA
Keywords                        : Software & Security#Remote Enterprise System Management#Baseboard Mangement Controller Management UtilitiesChassis Management ControllerLifecycle ControllerRemote Access ControllerWindows Debugger Utility##dell chassis mgmt cntrllr v1.30 pwedge vrtx#dell-chassis-mgmt-cntrllr-v1.30-pwedge-vrtx#Release Notes#dell chassis# poweredge vrtx chassis# dell vrtx cmc# dell chassis intrusion switch# dell cmc wsman# cmc redundancy is lost# chassis dell# vrtx chassis# Dell Chassis Management Controller (CMC) Version 1.30 for Dell PowerEdge VRTX Release Notes..
Create Date                     : 2014:01:29 13:37:19+05:30
Creator Tool                    : PScript5.dll Version 5.2.2
Modify Date                     : 2014:03:19 18:01:59-05:00
Page Mode                       : UseOutlines
Page Count                      : 5
Author                          : Dell Inc.
Productcode                     : dell-chassis-mgmt-cntrllr-v1.30-pwedge-vrtx
Typecode                        : rn
Typedescription                 : Release Notes
Languagecodes                   : en-us
Publishdate                     : 2014-03-19 00:00:00
Expirydate                      : 9999-09-09 00:00:00
Manualurl                       : ftp://ftp.dell.com/Manuals/all-products/esuprt_software/esuprt_remote_ent_sys_mgmt/esuprt_rmte_ent_sys_rmte_access_cntrllr/dell-chassis-mgmt-cntrllr-v1.30-pwedge-vrtx_Release Notes_en-us.pdf
Readytocopy                     : false
Isdeleted                       : False
Businesskeywords                : dell chassis# poweredge vrtx chassis# dell vrtx cmc# dell chassis intrusion switch# dell cmc wsman# cmc redundancy is lost# chassis dell# vrtx chassis# Dell Chassis Management Controller (CMC) Version 1.30 for Dell PowerEdge VRTX Release Notes..
Futureproductindication         : Yes
Categorypathforfutureproducts   : all-products/esuprt_software/esuprt_remote_ent_sys_mgmt/esuprt_rmte_ent_sys_rmte_access_cntrllr
Filesize                        : 60
Isrestricted                    : False
Productpath                     : esuprt_rmte_ent_sys_rmte_access_cntrllr
Creationdate                    : D:20140129133719+05'30'
Moddate                         : D:20140319124218-05'00'
EXIF Metadata provided by EXIF.tools

Navigation menu