Dell Chassis Management Controller Version 2 1 Owners Manual 2.1 Readme
2014-11-13
: Dell Dell-Chassis-Management-Controller-Version-2-1-Owners-Manual-118079 dell-chassis-management-controller-version-2-1-owners-manual-118079 dell pdf
Open the PDF directly: View PDF
.
Page Count: 9

file:///T|/htdocs/SOFTWARE/smdrac3/cmc/cmc2_10/en/readme/readme.TXT[10/26/2012 2:25:55 PM]
######################################################################
DELL(TM) CHASSIS MANAGEMENT CONTROLLER Version 2.10
######################################################################
Version: 2.10
Release Date: 31 August 2009
This document contains updated information about the Dell Chassis
Management Controller (CMC).
For more information about the CMC, including installation and
configuration information, see the "Dell Chassis Management Controller
Firmware Version 2.10 User Guide" and the "Dell OpenManage(TM) Server
Administrator User's Guide." These documents are located on the Dell
Support website at "support.dell.com".
######################################################################
TABLE OF CONTENTS
######################################################################
This file contains the following sections:
* Criticality
* Minimum Requirements
* Release Highlights
* Known Issues for CMC version 2.10
* Known Issues for Documentation
######################################################################
CRITICALITY
######################################################################
2 - Recommended
######################################################################
MINIMUM REQUIREMENTS
######################################################################
The following subsections list the operating systems that are compatible
with the CMC version 2.10.
======================================================================
SUPPORTED SYSTEMS
======================================================================
CMC version 2.10 is supported on the following Dell PowerEdge(TM) systems
in the Dell PowerEdge M1000-e system enclosure:

file:///T|/htdocs/SOFTWARE/smdrac3/cmc/cmc2_10/en/readme/readme.TXT[10/26/2012 2:25:55 PM]
* Dell PowerEdge M600
* Dell PowerEdge M605
* Dell PowerEdge M805
* Dell PowerEdge M905
* Dell PowerEdge M610
* Dell PowerEdge M710
======================================================================
SUPPORTED WEB BROWSERS
======================================================================
* Microsoft(R) Internet Explorer(R) 6.0 (32-bit) with SP1 for Windows
Server(R) 2000 family
* Microsoft Internet Explorer 6.0 (32-bit) with SP2 for Windows(R) XP and
Windows Server 2003 family
* Microsoft Internet Explorer 7.0 for Windows Vista(R), Windows XP, and
Windows Server 2003 family
* Mozilla Firefox(R) 1.5 (32-bit) - limited functionality
* Mozilla Firefox 2.0-3.x (32-bit).
=============================================
FIRMWARE VERSIONS
=============================================
* CMC Firmware Version: 2.10
=============================================
RECOMMENDED MODULE FIRMWARE VERSIONS
=============================================
Additional recommended chassis module firmware if CMC version 2.10 is installed.
* iDRAC Firmware Version: 1.50 (or later) for Dell PowerEdge M600,
Dell PowerEdge M605, Dell PowerEdge M805,
Dell PowerEdge M905
2.10 (or later) for Dell PowerEdge M610,
Dell PowerEdge M710
* BIOS Version: 2.1.4 for Dell PowerEdge M600
5.0.4 for Dell PowerEdge M605
2.0.2 for Dell PowerEdge M905, Dell PowerEdge M805
1.2.7 for Dell PowerEdge M610, Dell PowerEdge M710
* CPLD Version: 1.1.1 for Dell PowerEdge M600
1.1.0 for Dell PowerEdge M605
1.1.0 for Dell PowerEdge M905, Dell PowerEdge M805
1.0.2 for Dell PowerEdge M610, Dell PowerEdge M710
######################################################################

file:///T|/htdocs/SOFTWARE/smdrac3/cmc/cmc2_10/en/readme/readme.TXT[10/26/2012 2:25:55 PM]
RELEASE HIGHLIGHTS
######################################################################
Fixes and Enhancements in version 2.10
----------------------------------------
* IPv6 — CMC now supports the IPv6 protocol.
The IPv6 Ready Logo Committee's mission is to define the test
specifications for IPv6 conformance and interoperability testing,
provide access to self-test tools, and to deliver the IPv6 Ready Logo. The CMC
is Phase-2 IPv6 Ready Logo certified, and the Logo ID for the CMC is
02-C-000378 (Dell PowerEdge M1000e). For information on the IPv6 Ready Logo
Program, see www.ipv6ready.org.
* VLAN tagging — The CMC and the iDRACs now support the ability to
assign their network traffic to a virtual LAN (VLAN).
* Single sign-on for active directory accounts — Single sign-on allows
authenticated users using Microsoft® Active Directory® on their local systems
to automatically apply those credentials to the CMC Web user interface.
* Two-Factor Authentication using Smart Card — Provides added security
—a smart card plus a PIN to authenticate a user instead of only a password.
* Public Key Authentication (PKA) over SSH — Improves SSH scripting
automation by removing the need to embed or prompt for
user ID/password.
* Power management enhancements — Flexible redundancy modes: 1+1,
2+1, and 3+1 power supply redundancy. Additional fault-tolerant AC
redundant modes: 1+1, 2+2, and 3+3.
* Additional error reporting options — The iDRAC system events log (SEL) is displayed
on the Blade Status page eliminating the need to log into the iDRAC to
view the system events. Also, CMC events are now also posted to a remote syslog server.
* Remote Virtual Media File Share option — to map a file from a share drive
on the network to one or more blades through the CMC to deploy or
update an operating system.
* Ability to read and clear SEL entries for servers from the CMC command-line interface.
######################################################################
KNOWN ISSUES FOR BROWSERS
######################################################################
* In Internet Explorer version 6, the log data may not display. Instead
the "Loading Chassis Event Log..." message may be displayed.
To address this issue, go to Advanced Settings/Security and make sure
the "Allow active content to run in files on My Computer" option is
NOT checked.
* In Internet Explorer version 6, if the security setting is set to
'Restricted', the CMC User Interface on the Alert Management pages for
Email Alerts and SNMP Traps pops up a Security Information message

file:///T|/htdocs/SOFTWARE/smdrac3/cmc/cmc2_10/en/readme/readme.TXT[10/26/2012 2:25:55 PM]
stating that the page contains both secure and non-secure items and
will ask if you want to continue. Select "Yes". This is because
Internet Explorer version 6 does not allow the use of hidden IFRAMES
on secure (SSL) pages. (183022)
* In Firefox version 1.5, you must manually refresh pages. Automatic
page updating is not fully supported in this version of the Firefox
browser.
* In Internet Explorer version 6, after updating the active CMC you
may need to close the browser used to login to the CMC before
attempting to login again. (232942)
* When loading or sorting CMC log entries in a Firefox browser, you may get
a pop up warning about an unresponsive script. To prevent these warnings,
perform the following steps:
(a) In the Firefox address bar, enter "about:config".
(b) Scroll down and find the "dom.max_script_run_time" entry.
(c) Double-click that entry and change the value to at
least 30. (248345)
* When using the CMC Web Interface, a popup dialog may appear with the message
“Content from the website listed below is being blocked by the Internet
Explorer Enhanced Security Configuration. https//”.
You can perform one of two actions to prevent this popup dialog:
1. Uncheck the option on popup check box to
“Continue to prompt when website content is blocked” and click Close.
-OR-
2. Enable scripting (Javascript) in the Internet zone.
– From the browser menu, select:
Tools->Internet Options->Security Tab
– Select the “Internet” zone.
– Click the “Custom Level…” button.
– Scroll to “Scripting->Active scripting” section and
click Enable.
– Click the OK button.
Click the OK button. (297730)
######################################################################
KNOWN ISSUES FOR CMC Version 2.10
######################################################################
* CMC firmware 1.2 has enhanced the power allocation algorithms to
allow modular servers to receive higher power allocations. If you
downgrade the CMC to 1.10 or an earlier firmware version, servers with
the new higher power allocations may be powered off because the
earlier firmware cannot support the higher chassis power allocations.
If this occurs, power the server back on. (230143)
* After a CMC reset, the CMC may require up to one minute after the
login prompt is displayed before accepting the RACADM commands .
Commands issued prior to that time may receive an error message. (273716)

file:///T|/htdocs/SOFTWARE/smdrac3/cmc/cmc2_10/en/readme/readme.TXT[10/26/2012 2:25:55 PM]
* The RACADM command line tool uses TFTP to transfer image files for all
firmware updates. Only the default port for TFTP (69) is supported.
(157754)
* Clearing the CMC log may take up to one (1) minute to complete. (152860)
* If the CMC is on a private network without access to the Internet
and you are using Internet Explorer 6 SP 2 or Internet Explorer 7,
you may experience delays of up to 30 seconds when using remote
RACADM commands. (161019)
* Some USB-to-serial adapters generate a large number of spurious interrupts
when plugged in. If the adapter is connected to the CMC's serial port
when this happens, the CMC may become overloaded while attempting to service
these interrupts and may reboot. This problem is exacerbated when the
serial cable is very long, causing voltage levels to drop and noise on the
serial line to increase. To avoid this issue, Dell recommends first connecting
the USB-to-serial adapter into the USB port, before connecting to the CMC.
Dell also recommends disconnecting the adapter from the CMC before rebooting
or performing other power management functions on a system that is attached
to the CMC. (180373)
* If you setup Active Directory (AD) on the CMC using extended schema and the
built-in Administrator privilege object, and then attempt to login to the
CMC User Interface using this AD account, after a successful AD login, the
user name and privilege level displayed on the right-hand side of the User
Interface just beneath the log out link is displayed as a custom user rather
than the privilege as created on the AD side (example: Administrator,
power user). (183449)
* Using the RACADM command line utility, if you attempt to set the DNS
CMC Name or DNS Domain Name without the proper rules, (Rules: A string
of upto 63 (for CMC Name) / 254 (for DNS Domain Name) alphanumeric
characters (a-z, A-Z, 0-9) and hyphens ), the utility may display a non-
specific error message (ERROR: Unable to perform requested operation).
Enter a valid string for the above mentioned names.(173204)
* A 'racadm config' operation may fail, due to configuration property
definition changes across firmware versions. For example, if the set of
allowable values for a configuration property has been changed, and
a snapshot of the prior values (from 'racadm getconfig') is used in
a 'racadm config' operation on a newer version of firmware, the prior
values may no longer be accepted, and thus cause the racadm config
operation to fail.(229764)
To resolve this issue, comment out the prior value in the captured file,
and restart the 'racadm config' operation.
The following lists the racadm property definitions that differ, depending
on the CMC firmware version:
group: cfgNetTuning, object: cfgNetTuningNicSpeed
- CMC Firmware 1.0 and 1.10:

file:///T|/htdocs/SOFTWARE/smdrac3/cmc/cmc2_10/en/readme/readme.TXT[10/26/2012 2:25:55 PM]
Allowed values: 10, 100, 1000 (default 1000)
- CMC version 1.20 and later:
Allowed values: 10, 100 (default 100)
* While performing firmware updates on servers located in the
chassis, make sure there is minimal to no activities on the server
(for example, avoid running discovery on the servers through management
applications such as IT Assistant or running IPMI commands). (276448)
* While performing multiple iDRAC firmware updates, the CMC performs
CPU-intensive activities and may not respond or respond
slower for the first couple of minutes. Please refrain from running
additional commands during this period. (281719)
* Updating the firmware on an Infiniband IOM (IOMINF) causes the IOM to
reset at the end of the update procedure. (270706)
* When configuring network settings on the iDRAC using the CMC RACADM commands,
make sure the command executed is completed successfully, before running
another network configuration command. To ensure that the settings are
applied on the target iDRAC, check the current configuration using the
appropriate RACADM command or use the Web GUI. (322063)
* When using the remote RACADM windows client, on a management station with
Internet Explorer version 7.0 or above installed, to capture the existing RACADM configuration
into a file, the command fails due to a timeout issue, without giving a
success or failure message. Manually run the individual commands to capture
cfgServerInfo(for all required indexes), cfgKvmInfo and cfgAlerting groups
and add them to the configuration file.(303086)
* When browsing the Remote File Share page for the servers, some of the blade
servers may indicate in the 'Connect Status' column they are already connected.
The does not necessarily mean a Remote File Share is already in progress on
the blade server. It is possible the blade server may have a 'Virtual Media'
session in progress and in the connected state. In such situations and prior
to proceeding with the Remote File Share operations (Connect/Disconnect/Deploy),
please ensure the existing Virtual Media session on the blade server is not
inadvertently overridden. If this is the intention, then it is possible to
proceed with the Remote File Share operations and override the existing Virtual
Media session on the blade server. Similarly, if an existing Remote File Share
session was already in progress on the blade server, the 'Connect Status' column
would indicate a connected state and it would be possible to override the existing
Remote File Share session.(322091)
* When connecting to a switch with the connect command, an error message
'stty: /dev/ttyS1: unable to perform all requested operations: No such file
or directory' may be displayed. This message does not prevent you from
connecting you to the switch and may be ignored.(325197)
#####################################################################
KNOWN ISSUES FOR USER INTERFACE ONLINE HELP
#####################################################################

file:///T|/htdocs/SOFTWARE/smdrac3/cmc/cmc2_10/en/readme/readme.TXT[10/26/2012 2:25:55 PM]
No known issues for this release.
#####################################################################
KNOWN ISSUES FOR DOCUMENTATION
#####################################################################
No known issues for this release.
#####################################################################
FLEXADDRESS
#####################################################################
Required Module Firmware to use the Chassis FlexAddress feature with CMC 2.10:
----------------------------------------------------------------
Component | Required version
----------------------------------------------------------------
Ethernet Mezzanine card - | Firmware 4.4.1,
Broadcom M5708t/M5708is,M5708 | iSCSI boot firmware 2.7.11,
| PXE firmware 4.4.3
----------------------------------------------------------------
FC Mezzanine card - | BIOS 2.04 or later
QLogic QME2472
----------------------------------------------------------------
FC Mezzanine card - | BIOS 3.03a3 and firmware 2.72A2
Emulex LPe1105-M4
----------------------------------------------------------------
Blade Server BIOS | (PE M600) BIOS 2.1.4 or later
| (PE M605) BIOS 4.02 or later
| (PE M805) 1.1.2 or later
| (PE M905) 1.1.2 or later
| (PE M610) All BIOS versions
| (PE M710) All BIOS versions
----------------------------------------------------------------
iDRAC | Firmware 1.50 or later(PE M600,
| PE M605, PE M805, PE M905)
| or Firmware 2.10 or later(PE M610, PE M710)
----------------------------------------------------------------
CMC | Firmware 2.10
----------------------------------------------------------------
* FlexAddress: Prior to inserting the SD card into the CMC, verify the write
protection latch is in the "unlock" position.
The FlexAddress feature cannot be activated if the SD card is write-
protected.
* FlexAddress: The system BIOS must be upgraded prior to installing
FlexAddress. If not, a warning icon is displayed on the
server health page. Once the system BIOS is updated, the modular
server must be power cycled before the FlexAddress chassis-assigned
MAC addresses are accepted by the modular server. The CMC
displays that chassis-assigned MACs are configured but the server will
use the server-assigned MAC configuration.
* FlexAddress: If you issue a CMCCHANGEOVER or RACRESET and then log
into the CMC Web GUI, the FlexAddress Web page may take up
to a minute to update the switch configurations.

file:///T|/htdocs/SOFTWARE/smdrac3/cmc/cmc2_10/en/readme/readme.TXT[10/26/2012 2:25:55 PM]
* FlexAddress: If a chassis with a single CMC is downgraded with
firmware earlier than version 1.10, the FlexAddress feature and
configuration will be removed. Once the CMC firmware is upgraded
to 1.10 or later, the FlexAddress feature must be reactivated and
configured.
* FlexAddress: In a chassis with two CMCs, if you are replacing a CMC unit
with one that has firmware earlier than version 1.10, perform the
following procedure to ensure that the current FlexAddress feature and
configuration is not removed.
1. Ensure the active CMC firmware is always version 1.10 or later.
2. Remove the standby CMC and insert the new CMC in its place.
3. From the Active CMC, upgrade the standby CMC firmware to 1.10
or later.
Note: If you do not update the standby CMC firmware to 1.10 or later
and a failover occurs, the FlexAddress feature is not configured and
you will need to reactivate the feature.
* FlexAddress: Wake-On-LAN (WOL) requires BIOS to initialize MAC
values. When the FlexAddress feature is deployed for the first
time on a given modular server, it requires at least one power-up and
down sequence for FlexAddress to take effect. The reason for this is
the FlexAddress on Ethernet devices is programmed by the BIOS. The BIOS
needs to be functioning to program the address. This in turn requires
the modular server to be powered up. Once the power-up and power-down
sequence has been completed, FlexAddress is available for the
Wake-On-LAN (WOL) function. You may perform power-up and power-down sequence
on the modular server for fully deploying FlexAddress through the iDRAC
or CMC interface.
* When changing from a server-assigned MAC to a chassis-assigned MAC on
Linux operating systems, additional configuration steps may be
required.
o SLES 9 and SLES 10: You may need to run YAST (Yet another Setup
Tool) on your Linux system to configure the network devices
and then restart the network services.
o Red Hat® Enterprise Linux® version 4 and version 5: You may need
to run Kudzu, a utility to detect and configure new/changed hardware
on the system. Kudzu displays the Hardware Discovery Menu and detects
the MAC address change as hardware was removed and new hardware added.
* Prior to installing FlexAddress, you can determine the range
of MAC addresses contained on the Flexaddress feature card by
inserting the SD card into a USB “Memory Card Reader” and viewing
the file "pwwn_mac.xml". The clear text XML file on the SD card
contains an XML tag "mac_start" which is the first starting
hex MAC address that is used for this unique MAC address range.
The “mac_count” tag is the total number of MAC addresses that this
SD card allocates. The total MAC range allocated can be determined
by: "mac_start" + 0xCF (208 – 1) = mac_end.
Example:(starting_mac)00188BFFDCFA + 0xCF =(ending_mac)00188BFFDDC9
NOTE: Lock the SD card before inserting it in the USB
“Memory Card Reader” to prevent accidental modification of any of the
contents. You must unlock the SD card before inserting into the CMC.
######################################################################

file:///T|/htdocs/SOFTWARE/smdrac3/cmc/cmc2_10/en/readme/readme.TXT[10/26/2012 2:25:55 PM]
Information in this document is subject to change without notice.
(C) 2009 Dell Inc. All rights reserved.
Reproduction in any manner whatsoever without the written permission
of Dell Inc. is strictly forbidden.
Trademarks used in this text: "Dell", "OpenManage", and
"PowerEdge" are trademarks of Dell Inc.; "Microsoft", "Windows",
"Windows Vista", "Windows Server", "Windows XP", “Internet Explorer”,
and "Active Directory" are either trademarks or registered trademarks
of Microsoft Corporation in the United States and/or other countries;
"Firefox" is a registered trademark of Mozilla Foundation; "Red Hat" and
"Red Hat Enterprise Linux" are registered trademarks of Red Hat, Inc.
in the United States and other countries.
Other trademarks and trade names may be used in this document to refer
to either the entities claiming the marks and names or their products.
Dell Inc. disclaims any proprietary interest in trademarks and trade
names other than its own.
August 2009