Dell Lifecycle Controller 2 Version 1 3 0 Operating Instructions System Deployment From ISCSI And FCoE
2015-01-05
: Dell Dell-Dell-Lifecycle-Controller-2-Version-1-3-0-Operating-Instructions-137660 dell-dell-lifecycle-controller-2-version-1-3-0-operating-instructions-137660 dell pdf
Open the PDF directly: View PDF .
Page Count: 17
DeployingOperatingSystemoniSCSIandFCOELUN
Deploying Operating System on iSCSI &
FCOE LUN
This Dell Technical White Paper provides steps to explain the
deployment of OS on iSCSI & FCoE LUN on the 12th generation servers
of Dell.
Chankey Rajkhowa
Hamsaveni Narayana
DeployingOperatingSystemoniSCSIandFCOELUN
© 2013 Dell Inc. All rights reserved. Dell and its affiliates cannot be responsible for errors or omissions in typography or
photography. Dell and the Dell logo are trademarks of Dell Inc. Microsoft, Windows, and the Windows logo are either
registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries. Intel and Xeon are
registered trademarks of Intel Corporation in the U.S. and other countries. Other trademarks and trade names may be used in
this document to refer to either the entities claiming the marks and names or their products. Dell disclaims proprietary
interest in the marks and names of others.
July 2013 | Rev 1.0
DeployingOperatingSystemoniSCSIandFCOELUN
Executive Summary
ThiswhitepapergivesthebasicsofOperatingsystemdeploymenttoaniSCSILUN&FCoELUNonthe
12thgenerationserversofDell.
DeployingOperatingSystemoniSCSIandFCOELUN
TableofContents
Introduction..................................................................................................................................................5
iSCSIOverview..............................................................................................................................................5
iSCSI–basedSANArchitecture......................................................................................................................5
FlowChartforOSDeploymentUsingiSCSILUN...........................................................................................6
ConfiguringiSCSIBootParametersforQlogicandOSInstallation...............................................................8
FCoEOverview............................................................................................................................................11
Abbreviations..............................................................................................................................................17
References..................................................................................................................................................17
DeployingOperatingSystemoniSCSIandFCOELUN
Introduction
Thiswhitepaperdescribesinstalling,enabling,andconfiguringforInternetSmallComputerSystemInterface(iSCSI),
andFibreChanneloverEthernet(FCoE)foruniversalconvergednetworkadapters(UCNAs).
BootfromSANistheprocessofbootingaserverdirectlyfromadiskoperatingsystem(DOS)imagelocatedona
storageareanetwork(SAN).WhenbootingfromSAN,thestoragedeviceistypicallyidentifiedbyitsWorldWide
PortName(WWPN)andaLogicalUnitNumber(LUN).Byextendingtheserversystembootbasicinput/output
system(BIOS),bootfromSANfunctionalityisprovidedbythebootBIOScontainedintheDellserver.When
properlyconfigured,thecontrollerthenpermanentlydirectstheservertobootfromalogicalunit(physicaldisk
drive)ontheSANasifitwasalocalphysicaldiskdrive.
iSCSIOverview
iSCSIisan(InternetProtocol)IP–basedstoragenetworkingstandardforlinkingdatastoragefacilities.Bycarrying
SCSIcommandsoverIPnetworks,iSCSIisusedtofacilitatedatatransfersoverintranetsandtomanagestorage
overlongdistances.iSCSIcanbeusedtotransmitdataoverlocalareanetworks(LANs),wideareanetworks
(WANs),ortheInternetandcanenablelocation‐independentdatastorageandretrieval.
iSCSI–basedSANArchitecture
Host server or client system (iSCSI initiator)
Raiddiskarray(iSCSITarget)
IP Network
Individualvirtualdriveima
g
es
DeployingOperatingSystemoniSCSIandFCOELUN
FlowChartforOSDeploymentUsingiSCSILUN
DeployingOperatingSystemoniSCSIandFCOELUN
DeployingOperatingSystemoniSCSIandFCOELUN
ConfiguringiSCSIBootParametersforQlogicandOSInstallation
BysettingupabasiciSCSIbootconfiguration,youcanconfigureyourinitiator,contactnetworkdevices,andsetup
aniSCSIboottarget.WhensettingupabasiciSCSIbootconfigurationyoumustdothefollowing:
1. PressF10toopenLifecycleController.
2. Intheleftpane,clickSystemSetup,andthenclickAdvancedHardwareConfiguration.
DeployingOperatingSystemoniSCSIandFCOELUN
3. OntheSystemSetuppage,clickDeviceSettings.
4. SelectQlogicadapterandconfiguretheiSCSIinitiatornameandenablebootsupport.
DeployingOperatingSystemoniSCSIandFCOELUN
5. Restarttheserver.
6. BoottoOSmedia,selectiSCSILUNduringinstallation,andthencompletetheinstallation.
Note:Iftherearemultiplecontrollersinyoursystem,youriSCSIInitiatornamemaybedifferentforeach
controller.
Forothernetworkcards,differentadaptersettingsarepresent.Refertothementionedreferences.
IntelandBroadcom:
http://i.dell.com/sites/content/business/solutions/whitepapers/en/Documents/Instructions_to_Perform_B
oot_from_iSCSI_for_Dell_Storage_Arrays.pdf
Emulex:http://www‐dl.emulex.com/support/hardware/documentation/nif/12‐03/oc_boot_manual.pdf
DeployingOperatingSystemoniSCSIandFCOELUN
FCoEOverview
FCoEprovidesamethodtotransportFibreChannelframesontopofanEthernetinfrastructure.Insummary,
unalteredFibreChannelframesareencapsulatedinanEthernetheader,sentoveralosslessEthernetfabric,
andun‐encapsulatedwhentheyreachthetarget.
FCoE―basedSANArchitecture
InitiatorHostServer
FCoEHBA
SwitchwithFCoEsupport
StorageArray
Individualvirtualdriveimages
DeployingOperatingSystemoniSCSIandFCOELUN
FlowChartShowingOSDeploymentUsingFCoELUN
DeployingOperatingSystemoniSCSIandFCOELUN
DeployingOperatingSystemoniSCSIandFCOELUN
ConfiguringFCoEBootParametersforQlogicandOSInstallation
TosupportanFCoEbootprocess,anetworkadapteronthehostmusthaveaspeciallyconfiguredFCoEboot
firmware.Whenyouconfigurethefirmware,youenabletheadapterforthesoftwareFCoEbootandspecify
thebootLUNparameters.
1. PressF10toopenLifecycleController.
DeployingOperatingSystemoniSCSIandFCOELUN
2. Intheleftpane,clickSystemSetup,andthenclickAdvancedHardwareConfiguration.
3. OntheSystemSetuppage,clickDeviceSettings.
4. SelectQlogicadapterandconfigure
DeployingOperatingSystemoniSCSIandFCOELUN
5. Restarttheserver.
6. BoottoOSmediaandSelectFCoELUNduringinstallationandcompletetheinstallation.
Forothernetworkcards,differentadaptersettingsarepresent.Referthementionedreferences.
Intel:http://en.community.dell.com/techcenter/extras/m/white_papers/20118779.aspx
Bcom:http://en.community.dell.com/techcenter/extras/m/white_papers/20242976.aspx
Emulex:http://www‐dl.emulex.com/support/hardware/documentation/nif/12‐03/oc_boot_manual.pdf
DeployingOperatingSystemoniSCSIandFCOELUN
Abbreviations
BIOS:BasicInput/OutputSystem
HII:HumanInterfaceInfrastructure
IP:Internetprotocol
iSCSI:InternetSmallComputerSystemInterface
FCoE:FibreChanneloverEthernet
LUN:Logicalunitnumber
RAID:redundantarrayofindependentdisks
SAN:storageareanetwork
SCSI:SmallComputerSystemInterface
WWN:WorldWideName
References
http://i.dell.com/sites/content/business/solutions/whitepapers/en/Documents/Instructions_to_Perform_B
oot_from_iSCSI_for_Dell_Storage_Arrays.pdf
http://www‐dl.emulex.com/support/hardware/documentation/nif/12‐03/oc_boot_manual.pdf
http://www.intel.ie/content/dam/www/public/us/en/documents/guides/fcoe‐user‐guide.pdf
http://www‐dl.emulex.com/support/elx/r32/b24/docs/other/nif_bootcode_manual_elx.pdf
http://www‐dl.emulex.com/support/hardware/documentation/nif/12‐03/oc_boot_manual.pdf