Dell OpenManage Server Administrator SNMP Reference Guide Notes and Cautions NOTE: A NOTE indicates important information that helps you make better use of your computer. A CAUTION indicates potential damage to hardware or loss of data if instructions are not followed. __________________ Information in this publication is subject to change without notice. © 2003–2012 Dell Inc. All rights reserved. Reproduction of these materials whatsoever without the written permission of Dell Inc. is strictly forbidden. Trademarks used in this text: Dell™, the DELL™ logo, PowerEdge™, PowerVault™, and OpenManage™ are trademarks of Dell Inc. Microsoft® and Windows® are either trademarks or registered trademarks of Microsoft Corporation in the United States and/or other countries. Intel®, Itanium®, Pentium®, Atom®, and Celeron® are registered trademarks, and MMX™, Xeon™, and Core™ are trademarks of Intel Corporation in the United States and/or other countries. VESA® is a registered trademark of the Video Electronics Standards Association. AMD™, AMD Athlon™, AMD Opteron™, AMD Sempron™, AMD Turion™, AMD Phenom™, and AMD Duron™ are trademarks of Advanced Micro Devices, Inc. VIA C7™ and VIA Eden™ are either trademarks or registered trademarks of VIA Technology, Inc. Crusoe™ and Efficeon™ are trademarks of Transmeta Corporation in the USA and other countries. Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Dell Inc. disclaims any proprietary interest in trademarks and trade names other than its own. 2012 - 6 Contents 1 Introduction . . . . . . . . . . . . . . . . . . . . . . . Supported SNMP Versions . . . . . . . . . . . . . . . Introduction to the SNMP Reference Guide . . . . . . 17 17 18 Server Administrator Instrumentation MIB . . . . 18 Server Administrator Remote Access MIB . . . . 21 Server Administrator Baseboard Management Controller, ASF MIB . . . . . . . . . . . . . . . . . . . . . . . . . 21 Server Administrator Field Replaceable Unit MIB . 22 Server Administrator Storage Management MIB . 22 Server Administrator Change Management MIB . 23 Dell Remote Access Controller Out-of-Band MIB . 24 . . . . . 24 . . . . . . . . . . . . . 25 How This Guide Defines Technical Terms SNMP Basic Terminology . . . . 28 . . . . . . . . . . . . . . . . . . . . . . . 29 Frequently Used Terms in Variable Names Tables Section Organization . . . . . . . . . . . . . . . . Other Documents You May Need . . . . . . . . . 32 33 Introduction to the Server Administrator SNMP Subagent 33 SNMP Management Information Base Object Identifiers 35 SNMP Security . . . . . . . . . . . . . . . . . . . Management Actions SNMP Traps 2 36 . . . . . . . . . . . . . . . 37 . . . . . . . . . . . . . . . . . . . . 37 Dell OpenManage Server Administrator Version 7.1 39 What’s New in This Release . . . . . . . . . . . . . . Contents 39 3 Storage Management Group MIB iDRAC7 MIB 3 . . . . . . . . . 39 . . . . . . . . . . . . . . . . . . . . 40 Instrumentation MIB Version Group . . . . 41 Management Information Base Major Version Number 41 Management Information Base Minor Version Number 42 Management Information Base Maintenance Version Number 42 4 Systems Management Software Group . Systems Management Software . 43 . . . . . . . . . . . . 43 Systems Management Software Variable Values 5 6 . . . 47 System State Group . . . . . . . . . . . . . . . . . 49 System State Group Table . . . . . . . . . . . . . . . . 49 System State Table . . . . . . . . . . . . . . . . . 49 System State Table . . . . . . . . . . . . . . . . . 51 Chassis Information Group . . . . . . . . . . . 71 Chassis Information Group Tables . . . . . . . . . . . 71 . . . . . . . . . . . . . 71 . . . . . . . . . . . . . . . . . . . . . 84 Chassis Information Table UUID Table POST Log Table . Event Log Table . . . . . . . . . . . . . . . . . . 86 . . . . . . . . . . . . . . . . . . . 88 System BIOS Table . . . . . . . . . . . . . . . . . Firmware Table . . . . . . . . . . . . . . . . . . . 98 Intrusion Table . . . . . . . . . . . . . . . . . . . 101 Baseboard Table . . . . . . . . . . . . . . . . . . Chassis Information Group Variable Values 4 Contents 91 . . . . . . 103 108 7 Operating System Group . . . . . . . . . . . . Operating System Memory Table 8 System Resource Group 125 . . . . . . . . . . . . . . . . . . . . . System Resource Group Tables 123 131 131 . . . . . . . . . . . . . System Resource Map Table . . . . . . . . . . . . 131 . . . . . . . . . . 133 System Resource Owner Table System Resource Input/Output (I/O) Port Table . . 136 System Resource Memory Table . . . . . . . . . . 139 System Resource Interrupt Table . . . . . . . . . 142 System Resource Direct Memory Access (DMA) Table 145 System Resource Group Variable Values 9 Power Group 148 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 153 Power Group Tables . . . . . . . . . . . . . . . . . . . 153 Power Unit Table . . . . . . . . . . . . . . . . . . 153 Power Supply Table . . . . . . . . . . . . . . . . 156 Voltage Probe Table . . . . . . . . . . . . . . . . 160 Amperage Probe Table . . . . . . . . . . . . . . . 165 AC Power Switch Table . . . . . . . . . . . . . . 171 . . . . . . . . . . . . . . . 173 . . . . . . . . . . . . . . . . . . . . 176 AC Power Cord Table Battery Table Power Usage Table . . . . . . . . . . . . . . . . 178 Power Profile Table . . . . . . . . . . . . . . . . 184 Power Group Variable Values . 10 Thermal Group . . . . . . . . . . . . . . . . . . . Thermal Group Tables 187 . . . . . . . . . . . . . 201 . . . . . . . . . . . . . . . . . . Cooling Unit Table . . . . . . . . . . . . . . . . . Cooling Device Table . . . . . . . . . . . . . . . . Contents 201 201 204 5 Temperature Probe Table Thermal Group Variable Values 11 User Security Group . . . . . . . . . . . . . 209 . . . . . . . . . . . . . 215 . . . . . . . . . . . . . . . User Security Group Table User Security Table . . . . . . . . . . . . . . . . 219 . . . . . . . . . . . . . . . . 219 12 Remote Flash BIOS Group Remote Flash BIOS Group Table Remote Flash BIOS Table . . . . . . . . . . . . . . . . . . . . . . . . 223 223 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Port Group Tables . . . . . . . . . . . . . . . . . . . . Pointing Port Table 223 . . . . . . . . . . . . . Remote Flash BIOS Variable Values 13 Port Group 219 . . . . . . . . . . . . . . . . . 226 229 229 229 Keyboard Port Table . . . . . . . . . . . . . . . . 232 Processor Port Table . . . . . . . . . . . . . . . . 235 Memory Device Port Table Monitor Port Table . . . . . . . . . . . . . 238 . . . . . . . . . . . . . . . . . 241 Small Computer System Interface (SCSI) Port Table 244 Parallel Port Table Serial Port Table . . . . . . . . . . . . . . . . . 246 . . . . . . . . . . . . . . . . . . 250 Universal Serial Bus (USB) Port Table Port Group Variable Values 14 Device Group . Device Tables 6 Contents . . . . . . . 254 . . . . . . . . . . . . . . . 257 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 263 263 Pointing Device Table . . . . . . . . . . . . . . . 264 Keyboard Device Table . . . . . . . . . . . . . . . 266 Processor Device Table Cache Device Table . . . . . . . . . . 277 . . . . . . . . . . . . . . . . 279 Memory Device Table . . . . . 293 . . . . . . . . . . . . . . . 296 . . . . . . . . . . . . . . . . . . 299 Generic Device Table PCI Device Configuration Space Table Network Device Table . . . . . . 302 . . . . . . . . . . . . . . . 305 Managed System Services Device Table SD Card Unit Table . . . . . 313 . . . . . . . . . . . . . . . . . 315 SD Card Device Table System Slot Table 351 . . . . . . . . . . . . . . . . . 351 355 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Physical Memory Tables 351 . . . . . . . . . . . . . . . . System Slot Variable Values 16 Memory Group 322 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . System Slot Group Table 318 . . . . . . . . . . . . . . . Device Group Variable Values 15 Slot Group 285 . . . . . . . . . . . . . . . Memory Device Mapped Address Table . PCI Device Table 269 . . . . . . . . . . . . . . Processor Device Status Table 365 . . . . . . . . . . . . . . . . Physical Memory Array Table . . . . . . . . . . . Physical Memory Array Mapped Table Physical Memory Configuration Table 365 365 . . . . . . 371 . . . . . . . 374 Physical Memory Logging Table . . . . . . . . . . 377 Redundant Memory Unit Table . . . . . . . . . . . 379 . . . . . . . . . . . 382 . . . . . . . . . . . . 385 Physical Memory Card Table . Memory Group Variable Values . Contents 7 17 BIOS Setup Control Group . BIOS Setup Control Group Tables 391 . . . . . . . . . . . . . 391 . . . . . . . . . . . . . . . . . 402 Parallel Port Control Table . . . . . . . . . . . . . 404 . . . . . . . . . . . . . . 406 . . . . . . . . . . . . . . . . . 408 . . . . . . . . . . . . . . . . . . 410 Serial Port Control Table USB Control Table IDE Control Table Diskette Control Table . . . . . . . . . . . . . . . Network Interface Control Table BIOS Setting Table 414 . . . . . . . . . . . . . . . . . 417 . . . . . . . . . . . . . . 18 Local Response Agent Group LRA Global Settings . . . . . . . . . . . . . . . . 431 431 431 432 . . . . . . . . . . . . . . . . . . 434 Local Response Agent Variable Values 19 Cost of Ownership Group Cost of Ownership Table 436 439 . . . . . . . . . . . . 439 . . . . . . . . . . . . . . 439 COO Service Contract Table . . . . . . . . . . . . 450 . . . . . . . . . . . . . 452 . . . . . . . . . . . . . . . . 454 COO Cost Event Log Table COO Warranty Table . . . . . . . . . . . . . . . . . . . . Cost of Ownership Group Tables COO Lease Information Table . . . . . . . . . . . 456 COO Schedule Number Table . . . . . . . . . . . 459 . . . . . . . . . . . . . . . . . 460 COO Options Table COO Maintenance Table Contents 420 . . . . . . . . . . . . . LRA Global Settings Table 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . LRA Action Table 412 . . . . . . . . . . BIOS Group Variable Values LRA Group Tables 391 . . . . . . . . . . . . BIOS Setup Control Table SCSI Control Table . . . . . . . . . . . . . . . . . . . . . . . . 462 COO Repair Table . COO Trouble Ticket Table . . . . . . . . . . 466 . . . . . . . . . . . . . 468 Cost of Ownership Variable Values 20 Remote Access Group . DRAC 4 and DRAC 5 470 . . . . . . . . . . . . . . . . . . . . . . . . 473 473 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 473 . . . . . . . . . . . . . . . . . . . . . . . . . 479 Remote Access Table DRAC III 464 . . . . . . . . . . . . . . . . . COO Support Information Table Remote Access Table . . . . . . . . 489 . . . . . . . . . . . . . 497 . . . . . . . . . . . . . . . 502 Remote SNMP Trap Table Remote Dial-Up Table . . . . . 506 . . . . . . . . . . . . . . . 509 Remote User Dial-In Configuration Table Remote Dial-Out Table Remote Access Variable Values 21 Cluster Group Cluster Group 480 . . . . . . . . . . . . . . . Remote User Administration Table . 512 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 529 . . . . . . . . . . . . . . . . . . . . . . Cluster Table . . . . . . . . . . . . . . . . . . . . Cluster Group Variable Values . . . . . . . . . . . . . 529 529 532 22 Baseboard Management Controller Group 533 Baseboard Management Controller Group Tables Baseboard Management Controller Table . . . . 533 . . . . 533 Baseboard Management Controller Serial Interface Table 537 Baseboard Management Controller LAN Interface Table 541 Baseboard Management Controller Group Variable Values 545 Contents 9 23 Field Replaceable Unit Group Field Replaceable Unit Group Tables Field Replaceable Unit Table . . . . . . . . . . . . . . . . . . 549 . . . . . . . . . . . . 549 Field Replaceable Unit Group Variable Values 24 Storage Management Group Storage Management Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . 553 555 555 . . . . . . . . 557 . . . . . . . . . . . . . . . . . . . . 558 Storage Management Information Group Global Data Group 549 Physical Devices Group . . . . . . . . . . . . . . . . . 564 . . . . . . . . . . . . . . . . . . 565 . . . . . . . . . . . . . . . . . . . 589 Controller Table . Channel Table Enclosure Table . . . . . . . . . . . . . . . . . . . 594 Array Disk Table . . . . . . . . . . . . . . . . . . 605 Array Disk Enclosure Connection Table . . . . . . 623 . . . . . . . 626 . . . . . . . . . . . . . . . . . . . . . . 628 Array Disk Channel Connection Table Fan Table Fan Connection Table Power Supply Table . . . . . . . . . . . . . . . 635 . . . . . . . . . . . . . . . . 637 Power Supply Connection Table Temperature Probe Table . . . . . . . . . . 642 . . . . . . . . . . . . . 644 Temperature Probe Connection Table Enclosure Management Module Table . . . . . . . 650 . . . . . . 652 Enclosure Management Module Connection Table 657 Battery Table . . . . . . . . . . . . . . . . . . . . Battery Connection Table Logical Devices Group Virtual Disk Table 667 . . . . . . . . . . . . . . . . . 669 . . . . . . . . . . . . . . . . . . 669 Array Disk Logical Connection Table . Storage Management Event Group 10 Contents 660 . . . . . . . . . . . . . . . . . . . . 680 . . . . . . . . . . . 682 25 Change Management Group Inventory Group Device Group . . . . . . . . . 685 . . . . . . . . . . . . . . . . . . . . . 685 . . . . . . . . . . . . . . . . . . . . . . 686 . . . . . . . . . . . . . . . . 686 . . . . . . . . . . . . . . . . . . . . 688 Device Group Table Application Group . . . . . . . . . . . . . . 689 . . . . . . . . . . . . . . . . 691 Application Group Table Operating System Group Inventory Collector Product Information 692 . . . . . . . . 26 Dell Remote Access Controller Out-of-Band Group 695 Product Information Chassis Status . . . . . . . . . . . . . . . . . . . . 695 . . . . . . . . . . . . . . . . . . . . . 699 . . . . . . . . . . . . . . . 708 . . . . . . . . . . . . . . . . . . . . . 709 DRsCMCChangeTime Chassis Power . CMC Power Information . . . . . . . . . . . . . . . . . 710 . . . . . . . . . . . . . . . . . . 714 . . . . . . . . . . . . . . . . . . . . . . 716 CMC PSU Information Chassis Alerts Legacy Alerting 27 Traps 718 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Understanding the Trap Description . . . . . . . . . . 723 . . . . . . . . . . . . . . 727 . . . . . . . . . . . . . . . . . . 728 Understanding Trap Severity Instrumentation Traps 721 Miscellaneous Traps . . . . . . . . . . . . . . . . Temperature Probe Traps Cooling Device Traps . 729 . . . . . . . . . . . . . 731 . . . . . . . . . . . . . . . 733 Contents 11 Voltage Probe Traps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 737 Chassis Intrusion Traps . . . . . . . . . . . . . . 739 Redundancy Unit Traps . . . . . . . . . . . . . . . 740 . . . . . . . . . . . . . . . . 742 . . . . . . . . . . . . . . . 743 . . . . . . . . . . . . . . . . 744 Power Supply Traps Memory Device Traps Fan Enclosure Traps AC Power Cord Traps . Hardware Log Traps . . . . . . . . . . . . . . . 746 . . . . . . . . . . . . . . . . 747 Processor Device Status Traps . . . . . . . . . . 747 . . . . . . . . . . . . . . 749 . . . . . . . . . . . . . . . . . . . . 750 Pluggable Device Traps Battery Traps SD Card Device Traps . . . . . . . . . . . . . . . 751 RAC Traps . . . . . . . . . . . . . . . . . . . . . . . . 752 BMC Traps . . . . . . . . . . . . . . . . . . . . . . . . 757 28 Storage Management Alert Reference Alert Monitoring and Logging Viewing Alerts 763 763 . . . . . . . . . . . . . . . . . . . . . 764 . . . . . . . . . . . . . . . . . . SNMP Support for Storage Management Alerts 764 . . . . 765 . . . . . . . . . . . . . . 765 SNMP Trap Definitions . . . . . . . . . . . . . . . 766 SNMP Trap Variables . . . . . . . . . . . . . . . . 766 . . . . . . . . . . . . . . . . . . 767 SNMP Trap Forwarding Viewing SNMP Traps Alert Descriptions and Corrective Actions 29 iDRAC7 MIB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Supported Systems Contents . . . . . . . . . . . . . . . Alert Severity Levels 12 735 Amperage Probe Traps . . . . . . . . . . . . . . . . . . . 767 769 769 Blade Servers iDRAC7 Out-of-Band Group . . . . . . . . . . . 770 . . . . . . . . . . . . . . . 770 . . . . . . . . . . . . . . 770 RAC Information Group Chassis Information Group . . . . . . . . . . . . . 772 . . . . . . . . . . . . . 773 . . . . . . . . . . . . . . . . . . . . 776 . . . . . . . . . . . . . . . . . . . . . . 777 System Information Group Status Group Trap Variables 778 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 779 Storage Trap Group . . . . . . . . . . . . . . . . 791 Updates Trap Group . . . . . . . . . . . . . . . . 796 . . . . . . . . . . . . . . . . . . 796 System Trap Group Audit Trap Group Configuration Trap Group Common Data Types 801 . . . . . . 801 . . . . . . . . . . . . . . . . . . . Variables with Data Types of State Capabilities and State Capabilities Unique . . . . . . . . . . . . . . . . 802 . . . . . . . . . . . . . . . . . 804 . . . . . . . . . . . . . . . . . . . . . . . . 805 Dell Status Data Types Dell Date . 797 . . . . . . . . . . . . . A Standard Data Type Definitions Full Dates 806 . . . . . . . . . . . . . . . . . . . . . . B SNMP Sample Output Index 769 . . . . . . . . . . . . . . iDRAC7 Supported SNMP Versions iDRAC7 Traps 769 . . . . . . . . . . . . . . . . . . . Rack and Tower Servers . . . . . . . . . . . . . . 807 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 813 Contents 13 14 Contents Contents 15 16 Contents 1 Introduction This reference guide provides information about the Simple Network Management Protocol (SNMP) Management Information Base (MIB) which is applicable for Dell OpenManage Version 7.1. NOTE: This guide contains information that may also be applicable to earlier OpenManage supported platforms. This introduction is divided into two sections. The first section, "Introduction to the SNMP Reference Guide" on page 18, explains the SNMP Reference Guide design. All essential Simple Network Management Protocol (SNMP) terms are defined in this section. Some of the vocabulary may seem complex and unfamiliar to system administrators who are using SNMP for the first time. SNMP experts can skim this section, and beginners can read the section more carefully. The second section, "Introduction to the Server Administrator SNMP Subagent" on page 33, is a more technical introduction to the management information base (MIB) that underlies Server Administrator services. Supported SNMP Versions Operating System Supported OMSA SNMP version Windows SNMP v1 Linux SNMP v1 Introduction 17 Introduction to the SNMP Reference Guide This reference guide provides a formatted version of the following Management Information Base that are released with the current version of Dell OpenManage. Sections in this guide follow MIB groups and provide explanations and definitions for the terms used to define MIB objects. Content in this reference guide is organized as documented in the following subsections. General Content Table 1-1 describes the sections that provide general information about the MIBs documented in this guide. Table 1-1. General Content Sections in This Guide Section Topics MIB Group Number 1 Introduction to SNMP basics and to the MIBs that support Server Administrator services NA 26 Traps — describes in-band traps defined in the Server 5000 Administrator Instrumentation MIB and out-of-band traps sent by the Remote Access Controller (RAC) and Baseboard Management Controller (BMC). Appendix A Standard Data Type Definitions — defines standard data types used in this reference guide. NA Appendix B SNMP Sample Output — provides a sample SNMP output. NA Server Administrator Instrumentation MIB The Server Administrator Instrumentation MIB (filename 10892.mib) provides instrumentation data that allows you to monitor the health of a system with SNMP management applications. It provides: 18 • Information about the status of temperatures, power supplies, voltages, currents, fans, and memory at key points in the system • Rapid access to detailed fault and performance information gathered by industry standard systems management agents • Version information for Basic Input/Output System (BIOS), firmware, and operating system Introduction • A detailed account of every cost of ownership (COO) detail about your system In addition, traps are sent to report a change in status of the health of critical components. The Server Administrator Instrumentation MIB structures its MIB objects into groups of scalar objects or MIB tables that provide related information. Table 1-2 describes each Server Administrator Instrumentation MIB group and lists the MIB group number assigned to the MIB group. The Server Administrator Instrumentation MIB groups are identified by the SNMP OID 1.3.6.1.4.1.674.10892.1., where is the MIB group number assigned to the MIB group. See the relevant section for more information about the MIB objects defined in a MIB group. Table 1-2. Server Administrator Instrumentation MIB Sections in This Guide Section Topics MIB Group Numbers 2 Instrumentation MIB Version Group — defines version numbers of the Instrumentation MIB 1 3 Systems Management Software Group — defines information about the systems management software and the supported systems management standards 100 4 System State Group — defines status, state, and redundancy for 200 a system and its components 5 Chassis Information Group — defines chassis types, events, and 300 indicators 6 Operating System Group — defines variables for name, version, 400 service pack, and other information about a system’s operating system 7 System Resource Group — defines variables for input/output ports, memory, interrupts, and direct memory access 500 8 Power Group — defines variables for power units, power supplies, and their current and voltage probes 600 9 Thermal Group — defines variables for temperature probes and 700 cooling devices Introduction 19 Table 1-2. Server Administrator Instrumentation MIB Sections in This Guide Section Topics MIB Group Numbers 10 User Security Group — defines variables for creating and modifying user accounts 800 11 Remote Flash BIOS Group — defines variables for updating the 900 system’s BIOS remotely 12 Port Group — defines variables for major port types such as keyboard, monitor, small computer system interface (SCSI), Universal Serial Bus (USB), and parallel and serial ports 1000 13 Device Group — defines variables for pointing, keyboard, processor, cache, memory, and personal computer interface devices 1100 14 Slot Group — defines variables for the system’s slots 1200 15 Memory Group — defines variables for the system’s physical memory 1300 16 BIOS Setup Control Group — defines variables for BIOS functions such as boot sequence, speakers, Wake on the local area network (LAN), diskettes, ports, and network interface controllers (NIC) 1400 17 Local Response Agent Group — defines variables for global settings and actions. These variables allow users to predetermine how the system responds to a particular type of event 1500 18 Cost of Ownership Group — defines variables for tracking data 1600 on the system’s service contract, lease, repair records, trouble tickets, and so on 20 Cluster Group — defines variables for systems that operate as a 1800 cluster 21 Baseboard Management Controller Group — provides information about the Baseboard Management Controller (BMC) that may be present in your system. In addition to providing general information about the BMC, this group provides information about the serial and local area network (LAN) interfaces of the BMC 20 Introduction 1900 Table 1-2. Server Administrator Instrumentation MIB Sections in This Guide Section Topics 26 MIB Group Numbers Traps — defines the types of alerts that can be sent to report the 5000 status of critical components Server Administrator Remote Access MIB The Server Administrator Remote Access MIB (filename dcs3rmt.mib) provides in-band information about remote access hardware that may be present in your system. The Server Administrator Remote Access MIB structures its MIB objects into groups of scalar objects or MIB tables that provide related information. Table 1-3 describes each Server Administrator Remote Access MIB group and lists the MIB group number assigned to the MIB group. The Server Administrator Remote Access MIB groups are identified by the SNMP OID 1.3.6.1.4.1.674.10892.1. where is the MIB group number assigned to the MIB group. See the relevant section for more information about the MIB objects defined in a MIB group. Table 1-3. Server Administrator Remote Access MIB Sections in This Guide Section Topic MIB Group Numbers 19 Remote Access Group — provides information about remote 1700 access hardware that may be present in your system and defines variables for administrative users, SNMP trap destinations, modem configuration for dial-up networking, dial-in configuration, and dial-out destinations Server Administrator Baseboard Management Controller, ASF MIB The Server Administrator BMC MIB (filename DcAsfSrv.mib) provides information about the traps sent by BMC. The Server Administrator BMC MIB structures its MIB objects that provide related information. The BMC MIB groups are identified by the SNMP OID 1.3.6.1.4.1.3183.1.1. . The BMC MIB adheres to ASF 2.0 standard and hence the enterprise ID is wired for management (3183). Introduction 21 Server Administrator Field Replaceable Unit MIB The Server Administrator Field Replaceable Unit MIB (filename dcs3fru.mib) provides information about field replaceable unit (FRU) hardware that may be present in your system. The Server Administrator Field Replaceable Unit MIB structures its MIB objects into groups of scalar objects or MIB tables that provide related information. Table 1-4 describes each Server Administrator Field Replaceable Unit MIB group and lists the MIB group number assigned to the MIB group. The Server Administrator Field Replaceable Unit MIB groups are identified by the SNMP OID 1.3.6.1.4.1.674.10892.1. where is the MIB group number assigned to the MIB group. See the relevant section for more information about the MIB objects defined in a MIB group. Table 1-4. Server Administrator Field Replaceable Unit MIB Sections in This Guide Section Topic MIB Group Numbers 22 Field Replaceable Unit Group — provides information about 2000 field replaceable units that may be present in your system Server Administrator Storage Management MIB The Server Administrator Storage Management MIB (filename dcstorag.mib) provides storage management data that allows you to monitor the health of storage resources with SNMP management applications. Table 1-5 describes each Server Administrator Storage Management MIB group and lists the MIB group number assigned to the MIB group. The Server Administrator Storage Management MIB groups are identified by the SNMP OID 1.3.6.1.4.1.674. where is the MIB group number assigned to the MIB group. See the relevant section for more information about the MIB objects defined in a MIB group. 22 Introduction Table 1-5. Server Administrator Storage Management MIB Sections in This Guide Section Topics MIB Group Numbers 23 Storage Management Group — consists of definitions for the 10893 following MIB groups: • Storage Management Group • Storage Management Information Group • Global Data Group • Physical Devices Group • Logical Devices Group • Storage Management Event Group 27 Storage Management Alert Reference — lets you monitor the NA health of storage resources such as controllers, connectors, array disks, and virtual disks Server Administrator Change Management MIB The Server Administrator Change Management MIB (filename dellcm.mib) provides management data that allows you to monitor the inventory of devices and applications with SNMP management applications. Table 1-6 describes each Server Administrator Change Management MIB group and lists the MIB group number assigned to the MIB group. The Server Administrator Change Management MIB groups are identified by the SNMP OID 1.3.6.1.4.1.674. where is the MIB group number assigned to the MIB group. See the relevant section for more information about the MIB objects defined in a MIB group. Table 1-6. Server Administrator Change Management MIB Sections in This Guide Section Topics MIB Group Number 24 Change Management Group - describes the inventory data 10899 provided by the Change Management MIB that allows users to monitor devices and software present on a particular managed computer chassis Introduction 23 Dell Remote Access Controller Out-of-Band MIB The Dell Remote Access Controller Out-of-Band MIB (filename dellRAC.mib) provides management data that allows you to monitor the Chassis Management Controller. This MIB also contains information on RAC legacy alerting. Table 1-7 describes each Dell RAC Out-of-Band group and lists the MIB group number assigned to the MIB group. See the relevant section for more information about the MIB objects defined in a MIB group. Table 1-7. Dell RAC Out-of-Band MIB Section Topics 25 MIB Group Number The Dell RAC Out-of-Band MIB consists of information for 2 the following groups: • "Product Information" on page 695 • "Chassis Status" on page 699 • "Chassis Power" on page 709 • "CMC Power Information" on page 710 • "CMC PSU Information" on page 714 • "Chassis Alerts" on page 716 • "Legacy Alerting" on page 718 How This Guide Defines Technical Terms The following table provides information about where to find definitions for technical terms in this reference guide. Table 1-8. Where to Find Definitions for Technical Terms Type of Definition See Basic SNMP vocabulary. "Introduction" on page 17 MIB-group-specific variable values. Sections 3, 5, 7, 8, 9, and 11 MIB-group-specific MIB variables contain links to the through 18. tables that define these values in the last section of the section in which these variables are used. Systems management terms, acronyms, and commonly managed components referred to in this reference guide. 24 Introduction Glossary available on the Dell Support website at support.dell.com/manuals. Table 1-8. Where to Find Definitions for Technical Terms (continued) Type of Definition See Server Administrator-standard data types that specify Appendix A, "Standard Data variable values in this reference guide. Type Definitions" on page 801. SNMP Basic Terminology It is important to have a good understanding of the key technical terms used in this guide. This guide provides definitions for all essential terms used in describing the Server Administrator MIBs. For definitions on all essential terms and acronyms, see the Glossary available on the Dell Support website at support.dell.com/manuals. SNMP Master Agent Typically, the SNMP agent on a managed system consists of one SNMP master agent and zero or more SNMP extension agents. This SNMP agent extendable structure facilitates the addition of new MIB modules without having to rebuild the entire SNMP agent and is invisible to SNMP management applications. The SNMP master agent is responsible for receiving SNMP request protocol messages from SNMP management applications and sending SNMP response protocol messages. As part of processing SNMP request protocol messages, the SNMP master agent typically communicates with one or more SNMP extension agents. This communication does not involve standard SNMP protocol messages. The SNMP master agent uses an extension protocol that shields the SNMP extension agent from the standard SNMP protocol messages. The extension protocol also provides a way for SNMP extension agents to send SNMP event notifications (called traps in SNMPv1). The SNMP master agent is also responsible for sending SNMP event notification protocol messages to SNMP management applications. On supported operating systems, the SNMP master agent is provided with the operating system. For example, on supported Microsoft Windows operating systems, the Windows SNMP service is the SNMP master agent. For information on the versions of the SNMP protocol supported by the SNMP master agent, see the operating system documentation. Introduction 25 SNMP Extension Agent The SNMP extension agent is responsible for registering the MIB objects that it supports with the SNMP master agent and then processing requests from the SNMP master agent for those MIB objects. The SNMP extension agent also initiates event notifications to the SNMP master agent. The SNMP extension agent does not receive or send standard SNMP protocol messages. The SNMP extension agent communicates with the SNMP master agent using an extension protocol defined by the SNMP master agent. The Server Administrator SNMP subagent is an SNMP extension agent. Managed Object A managed object is any item in a computer system that can be singled out for discovery, monitoring, or user intervention and correction. NOTE: Not all managed objects described in this guide are supported by all systems. MIB A MIB acts as a structured road map for managed objects. As an Application Programming Interface (API), a MIB allows systems management tools to retrieve data maintained by an agent. The server administrator MIB is divided into several major groups of managed objects. Variable A variable is a component of a managed object. A temperature probe, for example, has a variable to describe its capabilities, its health or status, and certain indexes that you can use to locate specific temperature probes. One index for the probe would be the probe’s chassis number. Some systems may have multiple chassis—one chassis for the central processing unit and another chassis for storage. A chassis within a system can also have more than one temperature probe. Variables for a temperature probe include its capabilities, status, chassis index, and index. One-Based Index When an index is one-based, counting starts at 1. One-based indexing counts the first instance as 1, the second index as 2, and so on. 26 Introduction Zero-Based Index When an index is zero-based, counting starts at 0. Zero-based indexing counts the first instance as 0, the second index as 1, and so on. Fields Managed object variables contain fields. In this reference guide, managed object variables have the following fields defined: Name is the exact string by which the variable is known in the MIB. MIB variables are named according to the following conventions: • Variable names start with a lowercase letter. • Spaces are not allowed between words in the variable name. • Acronyms are in uppercase letters, except when an acronym is the first word in the variable name. • With the exception of the first letter of the variable name and acronyms, all other words in the variable name start with capital letters. The following variable names illustrate these conventions: • temperatureProbeLowerCriticalThreshold • coolingUnitIndex • pCIDeviceSpeed Object Identifier (OID) is the unique number assigned to an object defined in a MIB. An OID is written as a sequence of subidentifiers in decimal notation. Each OID in this reference guide has a prefix that identifies the managed objects as belonging to Dell: 1.3.6.1.4.1.674. The additional numbers identify the MIB group and subgroup as well as the table entry number of any variables. For example, the OID for the temperature probe managed object table is 700.20 and the variable for the location of the temperature probe (temperatureProbeLocationName) has an OID of 700.20.1.8. The full OIDs for these items are 1.3.6.1.4.1.674.10892.1.700.20 for the temperatureProbeTable and 1.3.6.1.4.1.674.10892.1.700.20.1.8 for the temperatureProbeLocation. For more information about the structure of OIDs, see "SNMP Management Information Base Object Identifiers" on page 35. Introduction 27 Description is a brief explanation of what a particular managed object does. Syntax defines the data type in which the values of the variable must be expressed. Most variables in this reference guide use standard data types such as string or boolean. All data types that are unique to server administrator variables are defined at the end of the section in which they occur. Standard data types are defined in "Standard Data Type Definitions" on page 801. Access specifies whether persons with administrative privileges can read but not modify the value of a variable (read only) or can both read and modify the value of a variable (read-write). Frequently Used Terms in Variable Names The following terms are frequently used in the name of a MIB variable: Capability refers to the actions an object can perform, or to actions that can be taken by the object. Hot-pluggable is an example of a capability. If a card is hot-pluggable, it can be replaced while a system is running. Capability settings refer to the capabilities of the object that the user can select from and activate if desired. Capability settings allow users of the server administrator to predetermine how an object behaves under specific conditions. Settings are the conditions of a manageable object that determine what happens when a certain value is detected in a component. For example, a user can set the upper critical threshold of a temperature probe to 75 degrees Celsius. If the probe reaches that temperature, the setting causes an alert to be sent to the management console. Some settings, when reached, can trigger a system shutdown or other response to prevent damage to the system. State refers to the condition of an object that has more than one condition. For example, an object may be in a not ready or in an enabled state. Status refers to the health of an object or how the object is functioning. For example, the status of a temperature probe that is measuring acceptable temperatures would be reported as normal. When the probe begins reading temperatures that exceed limits set by the user, it reports a critical status. 28 Introduction Tables This reference guide contains two types of tables: tables that are used to organize and define variable values and tables that define MIB objects. Readers must understand the difference between these two types of tables. SNMP Tables Most of the MIB objects defined in this reference guide are organized into SNMP tables. SNMP tables organize data into two-dimensional structural arrays. In SNMP, objects that have a relationship to other objects are called columnar objects. Columnar objects are objects used to form lists and tables. When a MIB group is divided into one or more discrete tables, the word table has a technical meaning. An example is the section of this reference guide entitled Universal Unique Identifier (UUID). The UUID object has a type and a value that uniquely identifies an object such as a chassis. The table defines all of the variables that comprise the managed object UUID. The following table is an example of an SNMP table. The table contains variables that must occur in a definite sequence. In the example table the defined variables are UUID Chassis Index, UUID Index, UUID Type, and UUID Value. Example SNMP Table UUID Table These objects comprise the Server Administrator definitions for the UUID. Name uUIDTable Object ID 1.3.6.1.4.1.674.10892.1.300.20 Description Defines the UUID table. Syntax SEQUENCE OF UUIDTableEntry Access Not accessible Introduction 29 UUID Table Entry Name uUIDTableEntry Object ID 1.3.6.1.4.1.674.10892.1.300.20.1 Description Defines the UUID table entry. Syntax UUIDTableEntry Access Not accessible Index uUIDIndex, uUIDchassisIndex UUID Chassis Index Name uUIDchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only UUID Index Name uUIDIndex Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.2 Description Defines the index of the UUID in a specified chassis. Syntax DellObjectRange Access Read-only UUID Type Name uUIDType Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.3 Description Defines the type of the UUID for this chassis. Syntax DellUUIDType Access Read-only 30 Introduction UUID Value Name uUIDValue Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.4 Description Defines the value of the UUID for this chassis. Syntax Octet String (SIZE[16]) Access Read-only Reference Guide Content Tables NOTE: Variable values are defined for any variable that is Server Administrator-specific. Industry-standard variable definitions are documented in "Standard Data Type Definitions" on page 801. Some of the tables in this guide have no technical significance in SNMP. These tables are designed to show information in a readable form. The following table, for example, defines the Server Administrator-specific variable, DellFanControlCapabilities. The table provides the name of the variable, its data type, the values that are valid for the variable, and the meaning of each value. Table 1-9. Example Variable Type Definition Table Variable Name: DellFanControlCapabilities Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) The fan’s capabilities are unknown. lowSpeedCapable(2) The fan can be set to low speed. highSpeedCapable(4) The fan can be set to high speed. lowOrhighSpeedCapable(6) The fan can be set to low or high speed. This type of table is used throughout the reference guide to list and define variable values. Tables that explain Server Administrator-specific variable values are located in the final section of sections that define Server Administrator-specific variables. In the preceding example, the variable name is DellFanControlCapabilities. This variable must be expressed as an integer and has four possible values: unknown, lowSpeedCapable, highSpeedCapable, and lowOrhighSpeedCapable. Introduction 31 Section Organization Sections in this reference guide are based on the Server Administrator MIBs, so the complexity of each section depends on the complexity of each MIB group. The first section provides a high-level introduction to the MIB group. If the group is defined by one or more tables, the second section lists these tables. The third section documents the variables that comprise the group, and if applicable, the variables that comprise the tables. The fourth section contains definitions for any Server Administrator-specific variables that are used in the section. The following example shows the typical content of these four sections: 1 BIOS Setup Control Group This section explains the purpose of the MIB group and summarizes the major features of the component groups. 2 BIOS Group Tables If there is more than one SNMP table for a group, this section lists all of the tables. For this BIOS group example, there are eight tables listed. In each section, double-clicking any table on the list takes you to that table. • BIOS Setup Control Table • SCSI Control Table • Parallel Port Control Table • Serial Port Control Table • USB Control Table • IDE Control Table • Diskette Control Table • Network Interface Control Table 3 Variables that make up each table in the group This section documents the variables for the eight tables that comprise the BIOS group. 32 Introduction 4 BIOS Variable Values This section explains any Server Administrator-specific variables and data types that are used in this section. In the BIOS group example, there are 17 unique, Server Administrator-specific variable meanings. Information on each Server Administrator-specific variable is presented in a formatted table. Other Documents You May Need In addition to this guide, you can access the following guides available on the Dell Support website at support.dell.com/manuals. On the Manuals page, click SoftwareSystems Management. Click the appropriate product link on the right-side to access the documents. • The Server Administrator Messages Reference Guide lists the messages that you can receive on your systems management console or on your operating system’s event viewer. This guide explains the text, severity, and cause of each message that the server administrator issues. • The Server Administrator CIM Reference Guide documents the Common Information Model (CIM) provider, an extension of the standard management object format (MOF) file. The Server-Administrator CIM provider documents supported classes of management objects. • The Glossary provides information on the terms used in this document. Introduction to the Server Administrator SNMP Subagent This guide provides formatted information drawn primarily from the MIB files written for the Server Administrator services that support the SNMP protocol. For each of the variables defined in the MIBs, the following fields are specified: • Variable name • OID or unique identifying number • Description • Data type of the variable (for example: integer, string, octet string) • Whether the variable is accessible, not accessible, read-only, or read-write • Index or indexes, if applicable Introduction 33 For each MIB group that has unique variable definitions, tables are included in the last section of the section to explain the meaning of the terms. Standards for writing MIBs are defined by the Internet Engineering Task Force (IETF). Structure of Management Information (SMI) is a standard that specifies the rules for defining the structure and type of managed objects and events in a MIB. SMIv1 is specified in Request For Comments (RFC) 1155. The Server Administrator MIB conforms to the SMIv1 standard. SNMP is a systems management standard originally designed for network management. SNMP manages much more than networks. Information Technology (IT) professionals use SNMP for monitoring and managing computer systems and the various components and peripherals supported by their systems. SNMP standards are defined by the Internet Engineering Task Force (IETF). SNMP version 1 was published in August 1988 and is the most commonly supported version of SNMP. SNMP version 2 was first published in May 1993, but has not gained widespread market acceptance. SNMP version 3 was recently completed and has addressed security issues that exist in version 1. All SNMP systems consist of one or more managed systems that provide data through an SNMP agent to a management system. The management system provides a user interface to view data from the managed systems. The management system and managed systems communicate over a network (typically through User Datagram Protocol/Internet Protocol [UDP/IP]). The management system and a managed system communicate by means of a common data schema. SNMP MIB files define the structure, type, and values of the SNMP data. While MIBs can be standardized or enterprise specific, most operating systems supply SNMP agents for the standard MIB-I and MIB-II schemas. MIB-I defines a base set of standard management information for systems implementing the Internet Protocol (IP) suite. MIB-II defines characteristics of the system, characteristics of network interfaces, and characteristics of components of the IP on the system. In addition to the standard MIBs, many hardware vendors have defined MIBs that provide management data specific to their systems and peripheral devices. Monitored data can be retrieved through SNMP using the Get command. Typically, this command requires the host name or IP address of the target machine as well as the OID of the data to retrieve. Exact details are dependent on the operating system and the development tools being used to create the management application. The Get command has a variant known as GetNext. 34 Introduction SNMP Management Information Base Object Identifiers Each data class within a Management Information Base (MIB) is defined by an Object Identifier (OID). OIDs are unique across all MIBs. An OID consists of a series of digits separated by periods. The OID functions in a similar fashion to a phone number. The phone number 011-512-471-0000 uniquely identifies a single phone. The phone number can be broken down into a number of components to uniquely identify a phone. The first component, 011, is the country code for the United States. The second component, 512, identifies the area code for central Texas. The third component, 471, is the phone exchange for a large state university in the city of Austin. The final component, 0000, is the main switchboard. There are two main differences between the phone number example and an actual OID. The first difference is that there are many more components in an OID, up to 128. The combination of these components is called an OID prefix. The second difference is that OIDs support the concept of indexes or keys. The OID prefix specifies the data class but does not specify an instance of the data within the class. Indexes can be used to identify the instances of a data class. These indexes are referred to as the OID suffix. The assignment of values for each OID prefix component can be illustrated by using a tree structure. The following is an example of an OID assignment: ROOT CCITT(0) ISO(1) ORG(3) DOD(6) INTERNET(1) MGMT(2) MIB(1) EXPERIMENTAL(3) PRIVATE(4) ENTERPRISES(1) DELL (674) SNMPv2(6) Introduction 35 In the preceding example, the OID prefix for the Dell enterprise would be 1.3.6.1.4.1.674. The numbers in boldface type show the categories and numbers that apply to Server Administrator. All Server Administrator-defined OIDs consist of 1.3.6.1.4.1.674 followed by additional component values. SNMP Security SNMP version 1 has a very limited security mechanism. SNMP agents support the use of a community string, which is configured at each SNMP agent and is passed as a part of all SNMP request messages. There is no verification that the requester is actually a member of the specified community. As most system and network management data is not confidential, this limited security is acceptable for Get types of requests. On the other hand, this security is not acceptable for Set types of operations where an SNMP request could power off a system, reconfigure a redundant array of independent disks (RAID) card, and so on. Some vendors have chosen not to support SNMP Set operations for this reason. Server Administrator is able to support SNMP Set operations because its SNMP agents implement a hash/digest mechanism to prevent unauthorized SNMP Set operations. One limitation of this practice is that only server administrator-developed SNMP management applications have the capability to support the hash/digest mechanism. NOTE: The default SNMP agent configuration usually includes a SNMP community name such as public. For security reasons, change the SNMP community names from their default values. For information about changing SNMP community names, see the Dell OpenManage Server Administrator User’s Guide available on the Dell Support website at support.dell.com/manuals. For additional guidelines, see the Securing an SNMP Environment article, dated May 2003, in the Dell Power Solutions magazine. This magazine is also available at dell.com/powersolutions. NOTE: Server Administrator provides support to enable or disable SNMP Set operations. For more information on enabling or disabling SNMP Set operations in Server Administrator, see the Dell OpenManage Server Administrator User’s Guide or the Dell OpenManage Server Administrator Command Line Interface User's Guide on the Dell Support website at support.dell.com/manuals. 36 Introduction Management Actions Management actions can be performed using the SNMP Set command. These actions can consist of configuring a phone number for the system’s owner, rebooting a system, or changing the asset tag of the system. See the previous section, "SNMP Security" on page 36, for limitations on Set operations. SNMP Traps SNMP is frequently used to monitor systems for fault conditions such as temperature violations, hard drive failures, and so on. Management applications can monitor for these conditions by polling the appropriate OIDs with the Get command and analyzing the returned data. This method has its drawbacks. If it is done frequently, significant amounts of network bandwidth can be consumed. If it is done infrequently, the response to the fault condition may not occur in a timely fashion. SNMP traps avoid these limitations of the polling method. An SNMP trap is an asynchronous event indicating that something significant has occurred. This is analogous to a pager receiving an important message, except that the SNMP trap frequently contains all the information needed to diagnose a fault. Two drawbacks to SNMP traps are that they are sent using UDP, which is not a guaranteed delivery mechanism, and that they are not acknowledged by the receiver. An SNMP trap message contains the trap’s enterprise OID, the agent IP address, a generic trap ID, the specific trap ID, a time stamp, and zero or more variable bindings (varbinds). The combination of an enterprise OID and a specific trap ID uniquely identifies each Server Administrator-defined trap. A varbind consists of an OID and its value and provides additional information about the trap. In order for a management system to receive SNMP traps from a managed system, the node must be configured to send traps to the management system. Trap destination configuration is dependent on the operating system. When this configuration is done, a management application on the management system can wait for traps and act on them when received. Introduction 37 For a list of traps supported by the Server Administrator Instrumentation Service, see "Instrumentation Traps" on page 696. For information on Server Administrator Storage Management traps, see "Storage Management Alert Reference" on page 753. For a list of traps supported by the Remote Access Controller, see "RAC Traps" on page 742, "BMC Traps" on page 747 and "iDRAC7 Traps" on page 767. 38 Introduction Dell OpenManage Server Administrator Version 7.1 2 This section contains information added or updated for the current release. What’s New in This Release Storage Management Group MIB • Added MIB table for Controller CacheCade. • Added MIB table for Controller Spin Down Configured Drives. • Added MIB table for Controller Automatic Power Saving. • Added MIB table for Controller Configured Drives SpinUp TimeInterval. • Added MIB table for Controller Preserved Cache. • Added MIB table for Array Disk Power State. • Added MIB table for Array Disk Drive Write Cache. • Added MIB table for Array Disk Model Number. • Added MIB table for Array Disk Life Remaining. • Added MIB table for Array Disk Driver Version. • Added MIB table for Array Disk Device Life Status. • Added MIB table for Power Supply Connection Firmware Version. • Added MIB table for Battery ID. • Added MIB table for Battery Learn Mode. • Modified the description for Controller Type. • Modified the description for Controller Persistent Hot Spare. • Modified the description for Controller Spin Down Unconfigured Drives. • Modified the description for Controller Spin Down Hot Spare Drives. • Modified the description for Channel Bus Type. • Modified the description for Enclosure ID. Updates for Dell OpenManage Server Administrator Version 7.1 • Modified the description for Array Disk State. • Modified the description for Array Disk Bus Type. • Modified the description for Array Disk Media Type. • Modified the description for Battery Learn State. • Modified the description for Virtual Disk Layout. iDRAC7 MIB • Updated the supported server information. For a list of Platforms, Operating Systems, Browsers support added and deprecated, refer to the Dell OpenManage Server Administrator Version 7.1 User's Guide and Dell Systems Software Support Matrix Version 7.1 at support.dell.com/manuals. 40 Dell OpenManage Server Administrator Version 7.1 3 Instrumentation MIB Version Group The Instrumentation Management Information Base (MIB) Version Group defines the attributes that identify the version of the Instrumentation MIB supported by the systems management software. The mIBMajorVersionNumber, mIBMinorVersionNumber, and mIBMaintenanceVersionNumber attributes are scalar objects, meaning that they are not related to other MIB objects and are thus not placed in a table. Management Information Base Major Version Number Name mIBMajorVersionNumber Object ID 1.3.6.1.4.1.674.10892.1.1.1.0 Description Defines the major version number of the version of this MIB supported by the systems management software. For example, if the MIB version is 1.2.3, the major version number is 1. A major version number change indicates a major change in object functionality. Syntax DellUnsigned8BitRange Access Read-only Instrumentation MIB Version Group 41 Management Information Base Minor Version Number Name mIBMinorVersionNumber Object ID 1.3.6.1.4.1.674.10892.1.1.2.0 Description Defines the minor version number of the version of this MIB supported by the systems management software. For example, if the MIB version is 1.2.3, the minor version number is 2. A minor revision provides additional support for new objects as well as problem fixes. Syntax DellUnsigned8BitRange Access Read-only Management Information Base Maintenance Version Number Name mIBMaintenanceVersionNumber Object ID 1.3.6.1.4.1.674.10892.1.1.3.0 Description Defines the maintenance version number for the version of this MIB supported by the systems management software. For example, if the MIB version is 1.2.3, the maintenance version number is 3. Syntax DellUnsigned8BitRange Access Read-only 42 Instrumentation MIB Version Group Systems Management Software Group 4 The Systems Management Software Group allows users to see information about the standards and software that are supported by the agent of a particular managed computer chassis. The Systems Management Software Group classifies each computer chassis according to the systems management standard that the agent supports. Additional objects define the universal resource locator (URL) of the systems management software and the language in which systems management information displays. Defining these objects enables users to manage a system using an internet browser. You can access Server Administrator using the secure hypertext transfer protocol (https) and a pre-assigned port number of 1311, or you can specify a port number of your own choosing. NOTE: Using the Software Server Preferences menu of Server Administrator, you can bind to either one IP address or to all IP addresses. To manage a system locally using Server Administrator, type the following in the address field of your browser: https://localhost:<1311 or user-specified port number> To manage a system remotely using Server Administrator, type one of the following in the address field of your browser: https:// :<1311 or user specified port number> or https:// :<1311 or user specified port number> Systems Management Software The following objects describe the fields for server administrator systems management information. The systems management software variables are scalar objects, meaning that they are not related to other management information base (MIB) objects and are thus not placed in a table. Systems Management Software Group 43 Systems Management Software Name Name systemManagementSoftwareName Object ID 1.3.6.1.4.1.674.10892.1.100.1 Description Defines the systems management software product name. Syntax DellString Access Read-only Systems Management Software Version Number Name Name systemManagementSoftwareVersionNumberName Object ID 1.3.6.1.4.1.674.10892.1.100.2 Description Defines the version number of the systems management software. Syntax DellString Access Read-only Systems Management Software Build Number Name systemManagementSoftwareBuildNumber Object ID 1.3.6.1.4.1.674.10892.1.100.3 Description Defines the build number of the systems management software. Syntax DellUnsigned16BitRange Access Read-only Systems Management Software Description Name Name systemManagementSoftwareDescriptionName Object ID 1.3.6.1.4.1.674.10892.1.100.4 Description Defines the description of the systems management software. Syntax DellString Access Read-only 44 Systems Management Software Group Systems Management Software Supported Protocol Name systemManagementSoftwareSupportedProtocol Object ID 1.3.6.1.4.1.674.10892.1.100.5 Description Defines the systems management standards (SNMP or CIM) supported by the systems management software. Syntax SMSSupportedTypes (See Table 4-1) Access Read-only Systems Management Software Preferred Protocol Name systemManagementSoftwarePreferredProtocol Object ID 1.3.6.1.4.1.674.10892.1.100.6 Description Defines the preferred systems management standard for the systems management software. Syntax SMSSupportedTypes (See Table 4-1) Access Read-only Systems Management Software Update Level Name Name systemManagementSoftwareUpdateLevelName Object ID 1.3.6.1.4.1.674.10892.1.100.7 Description Defines the update level of the system management software. Syntax DellString Access Read-only Systems Management Software URL Name Name systemManagementSoftwareURLName Object ID 1.3.6.1.4.1.674.10892.1.100.8 Description Defines the universal resource locator (URL) of the systems management software. Syntax DisplayString (SIZE (0..1024)) Systems Management Software Group 45 Name systemManagementSoftwareURLName Access Read-only Systems Management Software Language Name Name systemManagementSoftwareLanguageName Object ID 1.3.6.1.4.1.674.10892.1.100.9 Description Defines the language of the systems management software. Syntax DisplayString (SIZE (0..255)) Access Read-only Systems Management Software Global Version Name Name systemManagementSoftwareGlobalVersionName Object ID 1.3.6.1.4.1.674.10892.1.100.10 Description Defines the global version of the systems management software. Syntax DellString Access Read-only Systems Management Software Feature Flags Name systemManagementSoftwareFeatureFlags Object ID 1.3.6.1.4.1.674.10892.1.100.11 Description Defines the features of the systems management software. Syntax SMSFeatureFlags (See Table 4-2) Access Read-only Systems Management Software SNMP Agent Feature Flags Name systemManagementSoftwareSNMPAgentFeatureFlags Object ID 1.3.6.1.4.1.674.10892.1.100.12 Description Defines the features of the SNMP agent software provided by the operating system. 46 Systems Management Software Group Name systemManagementSoftwareSNMPAgentFeatureFlags Syntax SMSSNMPAgentFeatureFlags (See Table 4-3) Access Read-only Systems Management Software Manufacturer Name Name systemManagementSoftwareManufacturerName Object ID 1.3.6.1.4.1.674.10892.1.100.13 Description Defines the manufacturer of the systems management software. Syntax DellString Access Read-only Systems Management Software Variable Values This section includes definitions of server administrator-specific variable values used in this section. Table 4-1. Systems Management Software Supported Standards Variable Name: SMSSupportedTypes Data Type: Integer Possible Data Values Meaning of Data Value supportsSNMP(1) This system supports SNMP. supportsDMI(2) This system supports DMI. supportsSNMPandDMI(3) This system supports SNMP and DMI. supportsCIMOM(4) This system supports CIM. supportsSNMPandCIMOM(5) This system supports SNMP and CIM. Systems Management Software Group 47 Table 4-2. Systems Management Software Feature Flags Variable Name: SMSFeatureFlags Data Type: Integer Possible Data Values Meaning of Data Value none(0) The Systems Management Software features are not enabled. webOneToOneManagementPreferred(1) The web 1:1 management preferred feature is enabled. Table 4-3. Systems Management Software SNMP Agent Feature Flags Variable Name: SMSSNMPAgentFeatureFlags Data Type: Integer Possible Data Values Meaning of Data Value none(0) The Systems Management Software SNMP agent features are not enabled. supportsSparseTables(1) The SNMP agent supports sparse tables. 48 Systems Management Software Group 5 System State Group The Management Information Base (MIB) variables presented in this section enable you to track various attributes that describe the state of the critical components supported by your system. Components monitored under the System State Group include power supplies, AC power cords, AC power switches, and cooling devices, as well as temperature, fan, amperage, and voltage probes. System State Group Table The System State Group defines objects in the System State MIB table. System State Table The systemStateGlobalSystemStatus variable provides overall system health status and includes rolled-up (that is, worst) status for Instrumentation and Storage. This variable monitors the overall system health status. It reflects changes to systemStateChassisStatus variable, which represents Instrumentation health status and agentGlobalSystemStatus (dcstorag.mib), which represents Storage health status. The systemStateChassisStatus variable provides the rolled-up health status for the subsystems associated with the chassis that is represented by the row in the systemStateTable. Changes to the variables in "List 1" on page 50, each of which indicates the rolled-up health status of all the components of the corresponding subsystem, are reflected in systemStateChassisStatus variable. For example, systemStatePowerSupplyStatusCombined provides the rolledup status of all power supplies for the chassis. The variables in "List 2" on page 50 provide the health status of each component of the corresponding subsystem. Each octet of the value represents a component. If a power supply fails, the corresponding entry in systemStatePowerSupplyStatusDetails, systemStatePowerSupplyStatusCombined, systemStateChassisStatus, and systemStateGlobalSystemStatus transitions to critical. System State Group 49 List 1 Variables that provide rolled-up health status for all components in associated subsystem in chassis: • systemStatePowerSupplyStatusCombined • systemStateVoltageStatusCombined • systemStateAmperageStatusCombined • systemStateCoolingDeviceStatusCombined • systemStateTemperatureStatusCombined • systemStateMemoryDeviceStatusCombined • systemStateChassisIntrusionStatusCombined • systemStateACPowerCordStatusCombined • systemStateEventLogStatus • systemStatePowerUnitStatusCombined • systemStateCoolingUnitStatusCombined • systemStateACPowerSwitchStatusCombined • systemStateRedundantMemoryUnitStatusCombined • systemStateProcessorDeviceStatusCombined • systemStateBatteryStatusCombined • systemStateSDCardUnitStatusCombined • systemStateSDCardDeviceStatusCombined List 2 Variables that provide health status of each component in associated subsystem in chassis: 50 • systemStatePowerSupplyStatusDetails • systemStateVoltageStatusDetails • systemStateAmperageStatusDetails • systemStateCoolingDeviceStatusDetails • systemStateTemperatureStatusDetails • systemStateMemoryDeviceStatusDetails System State Group • systemStateChassisIntrusionStatusDetails • systemStateACPowerCordStatusDetails • systemStatePowerUnitStatusList • systemStateCoolingUnitStatusList • systemStateACPowerSwitchStatusList • systemStateRedundantMemoryUnitStatusList • systemStateProcessorDeviceStatusList • systemStateBatteryStatusList • systemStateSDCardUnitStatusList • systemStateSDCardDeviceStatusList System State Table The following object sets up the System State Table: Name systemStateTable Object ID 1.3.6.1.4.1.674.10892.1.200.10 Description Defines the System State Table. Syntax SEQUENCE OF SystemStateTableEntry Access Not accessible System State Table Entry Name systemStateTableEntry Object ID 1.3.6.1.4.1.674.10892.1.200.10.1 Description Defines the System State Table entry. Syntax SystemStateTableEntry Access Not accessible Index systemStatechassisIndex System State Group 51 System State Chassis Index Name systemStatechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only System State Global System Status Name systemStateGlobalSystemStatus Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.2 Description Defines the global system status of all chassis being monitored by this instrumentation instance. Syntax DellStatus Access Read-only System State Chassis State Name systemStateChassisState Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.3 Description Defines the system state of this chassis. Syntax DellStateSettings Access Read-only System State Chassis Status 52 Name systemStateChassisStatus Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.4 Description Defines the system status of this chassis. Syntax DellStatus Access Read-only System State Group System State Power Unit State Details Name systemStatePowerUnitStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.5 Description Defines the state of all power units in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the state of a specific power unit. The first byte returned represents the state of the first power unit, the second byte returned represents the state of the second power unit, and so on. The bytes have the same definition type as DellStateSettings. Syntax Octet String (Size (1..128)) Access Read-only System State Power Unit Status Redundancy Name systemStatePowerUnitStatusRedundancy Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.6 Description Defines the system status of the power unit(s) in this chassis. Syntax DellStatus Access Read-only System State Power Unit Status Details Name systemStatePowerUnitStatusDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.7 Description Defines the status of all power units in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the status of a specific power unit. The first byte returned represents the status of the first power unit, the second byte returned represents the status of the second power unit, and so on. The bytes have the same definition type as DellStatusRedundancy. Syntax Octet String (Size (1..128)) Access Read-only System State Group 53 System State Power Supply State Details Name systemStatePowerSupplyStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.8 Description Defines the state of all power supplies in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the state of a specific power supply. The first byte returned represents the state of the first power supply, the second byte returned represents the state of the second power supply, and so on. The bytes have the same definition type as DellStateSettings. Syntax Octet String (Size (1..128)) Access Read-only System State Power Supply Status Combined Name systemStatePowerSupplyStatusCombined Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.9 Description Defines the status of all power supplies in this chassis. Syntax DellStatus Access Read-only System State Power Supply Status Details Name systemStatePowerSupplyStatusDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.10 Description Defines the status of all power supplies in this chassis. The results are returned as a binary octet string, Each byte of the octet string represents the status of a specific power supply. The first byte returned represents the status of the first power supply, the second byte returned represents the status of the second power supply, and so on. The bytes have the same definition type as DellStatus. Syntax Octet String (Size (1..128)) Access Read-only 54 System State Group System State Voltage State Details Name systemStateVoltageStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.11 Description Defines the state of all voltage probes in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the status of a specific voltage probe. The first byte returned represents the status of the first voltage probe, the second byte returned represents the status of the second voltage probe, and so on. The bytes have the same definition type as DellStateSettings. Syntax Octet String (Size (1..128)) Access Read-only System State Voltage Status Combined Name systemStateVoltageStatusCombined Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.12 Description Defines the status of all voltage probes in this chassis. Syntax DellStatus Access Read-only System State Voltage Status Details Name systemStateVoltageStatusDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.13 Description Defines the status of all voltage probes in this chassis. Syntax Octet String (Size (1..128)) Access Read-only System State Group 55 System State Amperage State Details Name systemStateAmperageStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.14 Description Defines the state of all current probes in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the status of a specific current probe. The first byte returned represents the state of the first current probe, the second byte returned represents the state of the second current probe, and so on. The bytes have the same definition type as DellStateSettings. Syntax Octet String (Size (1..128)) Access Read-only System State Amperage Status Combined Name systemStateAmperageStatusCombined Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.15 Description Defines the status of all amperage probes in this chassis. The result is returned as a combined status value. The value has the same definition type as DellStatus. Syntax DellStatus Access Read-only System State Amperage Status Details Name systemStateAmperageStatusDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.16 Description Defines the status of all amperage probes in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the status of a specific amperage probe. The first byte returned represents the status of the first amperage probe, the second byte returned represents the status of the second amperage probe, and so on. The bytes have the same definition type as DellStatus. Syntax Octet String (Size (1..128)) Access Read-only 56 System State Group System State Cooling Unit State Details Name statesystemStateCoolingUnitStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.17 Description Defines the state of all cooling units in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the state of a specific cooling unit. The first byte returned represents the state of the first cooling unit, the second byte returned represents the state of the second cooling unit, and so on. The bytes have the same definition type as DellStateSettings. Syntax Octet String (Size (1..128)) Access Read-only System State Cooling Unit Status Redundancy Name systemStateCoolingUnitStatusRedundancy Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.18 Description Defines the state of all cooling units in this chassis. Syntax DellStatusRedundancy Access Read-only System State Cooling Unit State Details Name systemStateCoolingUnitstateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.19 Description Defines the state of all cooling units in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the state of a specific cooling unit. The first byte returned represents the state of the first cooling unit, the second byte returned represents the state of the second cooling unit, and so on. The bytes have the same definition type as DellStateSettings. Syntax Octet String (Size (1..128)) Access Read-only System State Group 57 System State Cooling Device State Details Name systemStateCoolingDeviceStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.20 Description Defines the state of all cooling devices in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the state of a specific cooling device. The first byte returned represents the state of the first cooling device, the second byte returned represents the state of the second cooling device, and so on. The bytes have the same definition type as DellStateSettings. Syntax Octet String (Size (1..128)) Access Read-only System State Cooling Device Status Combined Name systemStateCoolingDeviceStatusCombined Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.21 Description This attribute defines the cooling device status of all cooling devices in this chassis. The results is returned as a combined status value. The value has the same definition type as DellStatus. Syntax DellStatus Access Read-only System State Cooling Device Status Details Name systemStateCoolingDeviceStatusDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.22 Description Defines the status of all cooling devices in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the status of a specific cooling device. The first byte returned represents the status of the first cooling device, the second byte returned represents the status of the second cooling device, and so on. The bytes have the same definition type as DellStatus. Syntax Octet String (Size (1..128)) Access Read-only 58 System State Group System State Temperature State Details Name systemStateTemperatureStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.23 Description Defines the state of all temperature probes in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the state of a specific temperature probe. The first byte returned represents the state of the first temperature probe, the second byte returned represents the status of the second temperature probe, and so on. The bytes have the same definition type as DellStateSettings. Syntax Octet String (Size(1..128)) Access Read-only System State Temperature Status Combined Name systemStateTemperatureStatusCombined Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.24 Description Defines the status of all temperature probes in this chassis. The result is returned as a combined status value. The value has the same definition type as DellStatus. Syntax DellStatus Access Read-only System State Temperature Status Details Name systemStateTemperatureStatusDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.25 Description Defines the status of all temperature probes in this chassis. The first byte returned represents the status of the first temperature probe, the second byte returned represents the status of the second temperature probe, and so on. Syntax Octet String (Size(1..128) Access Read-only System State Group 59 System State Memory Device State Details Name systemStateMemoryDeviceStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.26 Description Defines the state of all memory devices in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the state of the specific memory device. The first byte returned represents the state of the first memory device, the second byte returned represents the status of the second memory device, and so on. The bytes have the same definition type as DellStateSettings. Syntax Octet String (Size(1..128) Access Read-only System State Memory Device Status Combined Name systemStateMemoryDeviceStatusCombined Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.27 Description Defines the status of all memory devices in this chassis. Syntax DellStatus Access Read-only System State Memory Device Status Details Name systemStateMemoryDeviceStatusDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.28 Description Defines the status of all memory devices in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the status of a specific memory device. The first byte returned represents the status of the first memory device, the second byte returned represents the status of the second memory device, and so on. The bytes have the same definition type as DellStatus. Syntax Octet String (Size(1..128) Access Read-only 60 System State Group System State Chassis Intrusion State Details Name systemStateChassisIntrusionStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.29 Description Defines the intrusion state of all intrusion detection devices in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the status of a specific intrusion detection device. The first byte returned represents the status of the first intrusion detection device, the second byte returned represents the status of the second intrusion detection device, and so on. The bytes have the same definition type as DellStateSettings. Syntax Octet String (Size(1..128) Access Read-only System State Chassis Intrusion Status Combined Name systemStateChassisIntrusionStatusCombined Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.30 Description Defines the intrusion status of all intrusion detection devices in this chassis. The result is returned as a combined status value. The value has the same definition type as DellStatus. Syntax DellStatus Access Read-only System State Chassis Intrusion Status Details Name systemStateChassisIntrusionStatusDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.31 Description Defines the intrusion status of all intrusion detection devices in this chassis. The first byte returned represents the status of the first intrusion detection device, the second byte returned represents the status of the second intrusion detection device, and so on. Syntax Octet String (Size(1..128)) Access Read-only System State Group 61 System State AC Power Switch State Details Name systemStateACPowerSwitchStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.32 Description Defines the individual state of all AC power switches in this chassis. The first byte returned represents the state of the first AC power switch, the second byte returned represents the state of the second AC power switch, and so on. Syntax Octet String (Size(1..128)) Access Read-only System State AC Power Switch Status Redundancy Name systemStateACPowerSwitchStatusRedundancy Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.33 Description Defines the overall redundancy status of the AC power switches in this chassis. Syntax DellStatusRedundancy Access Read-only System State AC Power Switch Status Details Name systemStateACPowerSwitchStatusDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.34 Description Defines the individual status of all AC power switches in this chassis. The first byte returned represents the status of the first AC power switch, the second byte returned represents the status of the second AC power switch, and so on. Syntax Octet String (Size(1..128)) Access Read-only 62 System State Group System State AC Power Cord State Details Name systemStateACPowerCordStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.35 Description Defines the individual state of all AC power cords for any AC power switches in this chassis. The first byte returned represents the state of the first AC power cord, the second byte returned represents the state of the second AC power cord, and so on. Syntax Octet String (Size(1..128)) Access Read-only System State AC Power Cord Status Combined Name systemStateACPowerCordStatusCombined Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.36 Description Defines the overall status of all AC power cords for any AC power switches in this chassis. Syntax DellStatus Access Read-only System State AC Power Cord Status Details Name systemStateACPowerCordStatusDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.37 Description Defines the individual status of all AC power cords for any AC power switches in this chassis. The first byte returned represents the status of the first AC power cord, the second byte returned represents the status of the second AC power cord, and so on. Syntax Octet String (SIZE(1..128)) Access Read-only System State Group 63 System State Redundant Memory Unit State Details Name systemStateRedundantMemoryUnitStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.38 Description Defines the state of all redundant memory units in this chassis. The results are returned as a binary octet string, each byte of the octet string represents the state of the specific object. The first byte returned represents the state of the first object, and so on. The bytes have the same definition type as DellStateSettings. Syntax Octet String (Size(1..128)) Access Read-only System State Redundant Memory Unit Status Redundancy Name systemStateRedundantMemoryUnitStatusRedundancy Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.39 Description Defines the overall redundancy status for redundant memory. Syntax DellStatusRedundancy Access Read-only System State Redundant Memory Unit Status Details Name systemStateRedundantMemoryUnitStatusDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.40 Description Defines the status of all redundant memory units in this chassis. The results are returned as a binary octet string, each byte of the octet string represents the status of the specific object. The first byte returned represents the status of the first object, and so on. The bytes have the same definition type as DellStatusRedundancy. Syntax Octet String (Size(1..128)) Access Read-only 64 System State Group System State Event Log Status Name systemStateEventLogStatus Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.41 Description Defines the overall status of this chassis (ESM) event log. Syntax DellStatus Access Read-only System State Power Unit Status Combined Name systemStatePowerUnitStatusCombined Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.42 Description Defines the combined status of all power units of this chassis. Syntax DellStatus Access Read-only System State Power Unit Status List Name systemStatePowerUnitStatusList Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.43 Description Lists the status of each power unit of this chassis. The results are returned as a binary octet string where each byte of the octet string represents the status of a power unit. The first byte returned represents the status of the first power unit, and so on. The bytes have the same definition type as DellStatus. Syntax Octet String (Size(1..128)) Access Read-only System State Group 65 System State Cooling Unit Status Combined Name systemStateCoolingUnitStatusCombined Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.44 Description Defines the combined status of all cooling units of this chassis. Syntax DellStatus Access Read-only System State Cooling Unit Status List Name systemStateCoolingUnitStatusList Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.45 Description Lists the status of each cooling unit of this chassis. The results are returned as a binary octet string where each byte of the octet string represents the status of a cooling unit. The first byte returned represents the status of the first cooling unit, and so on. The bytes have the same definition type as DellStatus. Syntax Octet String (Size(1..128)) Access Read-only System State AC Power Switch Status Combined Name systemStateACPowerSwitchStatusCombined Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.46 Description Defines the combined status of all AC power switches of this chassis. Syntax DellStatus Access Read-only 66 System State Group System State AC Power Switch Status List Name systemStateACPowerSwitchStatusList Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.47 Description Lists the status of each AC power switch of this chassis. The results are returned as a binary octet string where each byte of the octet string represents the status of an AC power switch. The first byte returned represents the status of the first AC power switch, and so on. The bytes have the same definition type as DellStatus. Syntax Octet String (Size(1..128)) Access Read-only System State Redundant Memory Unit Status Combined Name systemStateRedundantMemoryUnitStatusCombined Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.48 Description Defines the combined status of all redundant memory units of this chassis. Syntax DellStatus Access Read-only System State Redundant Memory Unit Status List Name systemStateRedundantMemoryUnitStatusList Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.49 Description Lists the status of each redundant memory unit of this chassis. The results are returned as a binary octet string where each byte of the octet string represents the status of a redundant memory unit. The first byte returned represents the status of the first redundant memory unit, and so on. The bytes have the same definition type as DellStatus. Syntax Octet String (Size(1..128)) Access Read-only System State Group 67 System State Processor Device Status Combined Name systemStateProcessorDeviceStatusCombined Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.50 Description Defines the combined status of all processor devices of this chassis. Syntax DellStatus Access Read-only System State Processor Device Status List Name systemStateProcessorDeviceStatusList Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.51 Description Lists the status of each processor device of this chassis. The results are returned as a binary octet string where each byte of the octet string represents the status of a processor device. The first byte returned represents the status of the first processor device, and so on. The bytes have the same definition type as DellStatus. Syntax Octet String (Size(1..128)) Access Read-only System State Battery Status Combined Name systemStateBatteryStatusCombined Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.52 Description Defines the combined status of all batteries of this chassis. Syntax DellStatus Access Read-only System State Battery Status List Name systemStateBatteryStatusList Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.53 68 System State Group Name systemStateBatteryStatusList Description Lists the status of each battery of this chassis. The results are returned as a binary octet string where each byte of the octet string represents the status of a battery. The first byte returned represents the status of the first battery, and so on. The bytes have the same definition type as DellStatus. Syntax Octet String (Size(1..128)) Access Read-only System State SD Card Unit Status Combined Name systemStateSDCardUnitStatusCombined Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.54 Description Defines the combined status of all SD Card units of this chassis. Syntax DellStatus Access Read-only System State SD Card Unit Status List Name systemStateSDCardUnitStatusList Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.55 Description Lists the status of each SD Card unit of this chassis. The results are returned as a binary octet string where each byte of the octet string represents the status of a SD Card unit. The first byte returned represents the status of the first SD Card unit, and so on. The bytes have the same definition type as DellStatus. Syntax Octet String (Size(1..128)) Access Read-only System State SD Card Device Status Combined Name systemStateSDCardDeviceStatusCombined Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.56 Description Defines the combined status of all SD Card devices of this chassis. System State Group 69 Name systemStateSDCardDeviceStatusCombined Syntax DellStatus Access Read-only System State SD Card Device Status List Name systemStateSDCardDeviceStatusList Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.57 Description Lists the status of each SD Card device of this chassis. The results are returned as a binary octet string where each byte of the octet string represents the status of a SD Card device. The first byte returned represents the status of the first SD Card device, and so on. The bytes have the same definition type as DellStatus. Syntax Octet String (Size(1..128)) Access Read-only 70 System State Group Chassis Information Group 6 The Chassis Information Group provides information about the type or types of chassis in your system, as well as information about the light-emitting diode (LED) indicators and settings for devices on each chassis. Information is also available about the current date and time displayed on the chassis, intrusion warnings, watchdog timer, systems management basic input/output system (SMBIOS), and so on. Chassis Information Group Tables The following management information base (MIB) tables define the objects in the Chassis Information Group: • "Chassis Information Table" on page 71 • "UUID Table" on page 84 • "POST Log Table" on page 86 • "Event Log Table" on page 88 • "System BIOS Table" on page 91 • "Firmware Table" on page 98 • "Intrusion Table" on page 101 • "Baseboard Table" on page 103 Chassis Information Table The following object sets up the Chassis Information Table. Name chassisInformationTable Object ID 1.3.6.1.4.1.674.10892.1.300.10 Description Defines the chassis information table. Syntax SEQUENCE OF ChassisInformationTableEntry Access Not accessible Chassis Information Group 71 Chassis Information Table Entry Name chassisInformationTableEntry Object ID 1.3.6.1.4.1.674.10892.1.300.10.1 Description Defines the chassis information table entry. Syntax ChassisInformationTableEntry Access Not accessible Index chassisIndexChassisInformation Chassis Index Chassis Information Name chassisIndexChassisInformation Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.1 Description Defines the index (one-based) of this chassis. The first chassis is numbered one. Syntax DellObjectRange Access Read-only Chassis State Capabilities Name chassisStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.2 Description Defines the capabilities of the chassis. Syntax DellStateCapabilities Access Read-only Chassis State Settings Name chassisStateSettings Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.3 Description Defines the state settings for the chassis. Syntax DellStateSettings Access Read-write 72 Chassis Information Group Chassis Status Name chassisStatus Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.4 Description Defines the status of the chassis. Syntax DellStatus Access Read-only Chassis Parent Index Reference Name chassisparentIndexReference Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.4 Description Defines the index (one-based) of the parent chassis of this chassis, if any. A zero (0) means that this chassis is the parent of all other chassis managed by the Server Administrator. Syntax DellObjectRange Access Read-only Chassis Type Name chassisType Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.6 Description Defines the chassis type. Syntax DellChassisType (See Table 6-2) Access Read-only Chassis Name Name chassisName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.7 Description Defines the user-assigned chassis name of the chassis. Syntax DellString Access Read-write Chassis Information Group 73 Chassis Manufacturer Name Name chassisManufacturerName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.8 Description Defines the manufacturer’s name for this chassis. Syntax DellString Access Read-only Chassis Model Name Name chassisModelName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.9 Description Defines the system model type for this chassis. Syntax DellString Access Read-only Chassis Asset Tag Name Name chassisAssetTagName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.10 Description Defines the user-assigned asset tag name for this chassis. Syntax DisplayString (SIZE (0..10)) Access Read-write Chassis Service Tag Name Name chassisServiceTagName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.11 Description Defines the service tag name for this chassis. Syntax DisplayString (SIZE (0..7)) Access Read-only 74 Chassis Information Group Chassis ID Name chassisID Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.12 Description Defines the asset tag name for this chassis. Syntax DellUnsigned8BitRange Access Read-only Chassis ID Extension Name chassisIDExtension Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.13 Description Defines the SMBIOS machine ID of this chassis. Syntax DellUnsigned16BitRange Access Read-only Chassis System Class Name chassisSystemClass Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.14 Description Defines the chassis class of this chassis. Syntax DellChassisSystemClass (See Table 6-21) Access Read-only Chassis System Name Name chassisSystemName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.15 Description Defines the system name of this chassis. Syntax DellString Access Read-only Chassis Information Group 75 Chassis System Boot Date Name Name chassisSystemBootDateName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.16 Description Defines the boot time of this system. Syntax DellDateName Access Read-only Chassis System Date Name Name chassisSystemDateName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.17 Description Defines the current time on this system. Syntax DellDateName Access Read-only Chassis System Location Name Name chassisSystemLocationName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.18 Description Defines the user-assigned location for this chassis. Syntax DellString Access Read-write Chassis System Primary User Name Name chassisSystemPrimaryUserName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.19 Description Defines the user-assigned primary user name for this chassis. Syntax DellString Access Read-write 76 Chassis Information Group Chassis System User Phone Number Name Name chassisSystemUserPhoneNumberName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.20 Description Defines the user-assigned phone number of the primary user of the system. Syntax DellString Access Read-write Chassis Connection Status Unique Name chassisConnectionStatusUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.21 Description Defines the status of the connection from the system chassis to an expansion chassis. Syntax DellConnectionStatus (See Table 6-3) Access Read-only Chassis Fan Control Capabilities Unique Name chassisFanControlCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.22 Description Defines the capabilities of the fan control function in this chassis. Syntax DellFanControlCapabilities (See Table 6-4) Access Read-only Chassis Fan Control Settings Unique Name chassisFanControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.23 Description Defines the readings and settings of the fan control hardware in the chassis. Syntax DellFanControlSettings Access Read-write Chassis Information Group 77 Chassis LED Control Capabilities Unique Name chassisLEDControlCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.24 Description Defines the capabilities of the LED control function in the chassis. Syntax DellLEDControlCapabilities (See Table 6-5) Access Read-only Chassis LED Control Settings Unique Name chassisLEDControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.25 Description Defines the readings and settings of the LED control hardware in the chassis. Syntax DellLEDControlSettings (See Table 6-6) Access Read-write Chassis Hard-Drive (HD) Fault Clear Control Capabilities Name chassisHDFaultClearControlCapabilities Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.26 Description Specifies whether the chassis allows reset of the chassis hard-drive fault LED. Syntax DellHDFaultLEDControlCapabilities (See Table 6-7) Access Read-only Chassis HD Fault Clear Control Settings Name chassisHDFaultClearControlSettings Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.27 Description Allows reset of the chassis hard-drive fault LED. Syntax DellHDFaultLEDControlSettings (See Table 6-8) Access Read-write 78 Chassis Information Group Chassis Identify Flash Control Capabilities Name chassisIdentifyFlashControlCapabilities Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.28 Description Specifies whether the chassis front-panel LED can be set to flash. Syntax DellChassisIdentifyControlCapabilities (See Table 6-9) Access Read-only Chassis Identify Flash Control Settings Name chassisIdentifyFlashControlSettings Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.29 Description Causes the chassis front-panel LED to flash. Syntax DellChassisIdentifyControlSettings (See Table 6-10) Access Read-write Chassis Lock Present Name chassisLockPresent Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.30 Description Specifies whether a chassis lock is present on the chassis. Syntax DellBoolean Access Read-only Chassis Host Control Capabilities Unique Name chassishostControlCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.31 Description Defines the capabilities of the host control object. Syntax DellHostControlCapabilities (See Table 6-11) Access Read-only Chassis Information Group 79 Chassis Host Control Settings Unique Name chassishostControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.32 Description Defines the current settings of the host control object. Syntax DellHostControlSettings (See Table 6-12) Access Read-write Chassis Watchdog Control Capabilities Unique Name chassiswatchDogControlCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.33 Description Defines the capabilities of the watchdog timer object. Syntax DellWatchDogControlCapabilities (See Table 6-13) Access Read-only Chassis Watchdog Control Settings Unique Name chassiswatchDogControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.34 Description Defines the current settings and the values allowed to be set for the watchdog timer object. Syntax DellWatchDogControlCapabilities (See Table 6-13) Access Read-write Chassis Watchdog Control Expiry Time Capabilities Unique Name chassiswatchDogControlExpiryTimeCapabilities Unique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.35 Description Defines the capabilities of the watchdog expiry timer object. Syntax DellWatchDogTimerCapabilities (See Table 6-13) Access Read-only 80 Chassis Information Group Chassis Watchdog Control Expiry Time Name chassiswatchDogControlExpiryTime Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.36 Description Defines the current reading and allows setting of the nonrecoverable watchdog expiry timer object. Syntax DellUnsigned16BitRange Access Read-write Chassis Allow Set Commands From SNMP Name chassisallowSETCommandsfromSNMP Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.37 Description Specifies whether Simple Network Management Protocol (SNMP) Set type commands are allowed by Server Administrator. This attribute does not reflect whether SNMP Set type commands are allowed by the SNMP master agent. Syntax DellBoolean Access Read-only Chassis Power Button Control Capabilities Unique Name chassisPowerButtonControlCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.38 Description Defines the capabilities of the power button control function. Syntax DellPowerButtonControlCapabilities (See Table 6-16) Access Read-only Chassis Power Button Control Settings Unique Name chassisPowerButtonControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.39 Description Defines the current reading and allows setting of the power button control hardware. Chassis Information Group 81 Name chassisPowerButtonControlSettingsUnique Syntax DellPowerButtonControlSettings (See Table 6-17) Access Read-write Chassis Reseller Name Name chassisResellerName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.40 Description Defines the name of the chassis reseller. Syntax DisplayString (SIZE (0..128)) Access Read-only Chassis Reseller Contact Information Name Name chassisResellerContactInformationName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.41 Description Defines the chassis reseller contact information name. Syntax DisplayString (SIZE (0..128)) Access Read-only Chassis Reseller Product Name Name chassisResellerProductName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.42 Description Defines the chassis reseller product name. Syntax DisplayString (SIZE (0..128)) Access Read-only Chassis Reseller System ID Name chassisResellerSystemID Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.43 Description Defines the chassis reseller system ID. 82 Chassis Information Group Name chassisResellerSystemID Syntax DellUnsigned16BitRange Access Read-only Chassis NMI Button Control Capabilities Unique Name chassisNMIButtonControlCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.44 Description Defines the capabilities of the NMI button control function. Syntax DellNMIButtonControlCapabilities (See Table 6-18) Access Read-only Chassis NMI Button Control Settings Unique Name chassisNMIButtonControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.45 Description Defines the current reading and allows setting of the NMI button control hardware. Syntax DellNMIButtonControlSettings (See Table 6-19) Access Read-write Chassis System Properties Name chassisSystemProperties Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.46 Description Defines the properties of the system. Syntax DellSystemProperties (See Table 6-20) Access Read-only Chassis Information Group 83 Chassis System Revision Number Name chassisSystemRevisionNumber Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.47 Description Defines the revision number of the system where zero indicates the original version of the system. The revision number is not available on all systems. Syntax DellUnsigned8BitRange Access Read-only Chassis System Revision Name Name chassisSystemRevisionName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.48 Description Defines the revision name of the system, if applicable. Syntax DellString Access Read-only Chassis Express Service Code Name Name chassisExpressServiceCodeName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.49 Description Defines the express service code of the chassis. Syntax DellString Access Read-only UUID Table These objects comprise the server administrator definitions for the Universal Unique Identifier (UUID). Name uUIDTable Object ID 1.3.6.1.4.1.674.10892.1.300.20 Description Defines the UUID table. Syntax SEQUENCE OF UUIDTableEntry 84 Chassis Information Group Name uUIDTable Access Not accessible UUID Table Entry Name uUIDTableEntry Object ID 1.3.6.1.4.1.674.10892.1.300.20.1 Description Defines the UUID table entry. Syntax UUIDTableEntry Access Not accessible Index uUIDIndex, uUIDchassisIndex UUID Chassis Index Name uUIDchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only UUID Index Name uUIDIndex Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.2 Description Defines the index of the UUID in a specified chassis. Syntax DellObjectRange Access Read-only UUID Type Name uUIDType Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.3 Description Defines the type of the UUID for this chassis. Chassis Information Group 85 Name uUIDType Syntax DellUUIDType Access Read-only UUID Value Name uUIDValue Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.4 Description Defines the value of the UUID for this chassis. Syntax Octet String (SIZE(16)) Access Read-only POST Log Table This section defines attributes for the power-on self-test (POST) log. When you turn on your computer, the POST checks various system components before the operating system loads. The POST tests the random-access memory (RAM), the hard drives, and the keyboard, for example. While the POST is running, it makes a log file that system administrators can view. The variables in this section also contribute to managing the POST log. Name postLogTable Object ID 1.3.6.1.4.1.674.10892.1.300.30 Description Defines the POST Log Table. Syntax SEQUENCE OF PostLogTableEntry Access Not accessible POST Log Table Entry Name postLogTableEntry Object ID 1.3.6.1.4.1.674.10892.1.300.30.1 Description Defines the POST Log Table entry. Syntax PostLogTableEntry 86 Chassis Information Group Name postLogTableEntry Access Not accessible Index postLogchassisIndex, postLogRecordIndex POST Log Chassis Index Name postLogchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.300.30.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only POST Log Record Index Name postLogRecordIndex Object ID 1.3.6.1.4.1.674.10892.1.300.30.1.2 Description Defines the record number (one-based) of the POST log. Syntax DellUnsigned32BitRange Access Read-only POST Log State Capabilities Unique Name postLogStateCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.300.30.1.3 Description Defines the capabilities of the object that is writing the POST log. Syntax DellStateCapabilitiesLogUnique Access Read-only POST Log State Settings Unique Name postLogStateSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.300.30.1.4 Description Defines the state of the object that is writing the POST log. Chassis Information Group 87 Name postLogStateSettingsUnique Syntax DellStateSettingsLogUnique Access Read-write POST Log Record Name postLogRecord Object ID 1.3.6.1.4.1.674.10892.1.300.30.1.5 Description Defines the data for the specified chassis and record index in the POST log being returned. Syntax DisplayString (SIZE (0..1024)) Access Read-only POST Log Format Name postLogFormat Object ID 1.3.6.1.4.1.674.10892.1.300.30.1.5 Description Defines format of the POST log. Syntax DellLogFormat (See Table 6-1) Access Read-only Event Log Table Name eventLogTableEntry Object ID 1.3.6.1.4.1.674.10892.1.300.40 Description Defines the Event Log Table. Syntax SEQUENCE OF EventLogTableEntry Access Not accessible Event Log Table Entry Name eventLogTableEntry Object ID 1.3.6.1.4.1.674.10892.1.300.40.1 88 Chassis Information Group Name eventLogTableEntry Description Defines the event Log Table Entry. Syntax EventLogTableEntry Access Not accessible Index eventLogchassisIndex,eventLogRecordIndex Event Log Chassis Index Name eventLogchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.300.40.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Event Log Record Index Name eventLogRecordIndex Object ID 1.3.6.1.4.1.674.10892.1.300.40.1.2 Description Defines the record index of the event log. Syntax DellUnsigned32BitRange Access Read-only Event Log State Capabilities Unique Name eventLogStateCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.300.40.1.3 Description Defines the capabilities of the object that is writing the event log. Syntax DellStateCapabilitiesLogUnique Access Read-only Chassis Information Group 89 Event Log State Settings Unique Name eventLogStateSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.300.40.1.4 Description Defines the state settings for the object that is writing the event log. Syntax DellStateSettingsLogUnique Access Read-write Event Log Record Name eventLogRecord Object ID 1.3.6.1.4.1.674.10892.1.300.40.1.5 Description Defines the data for the specified chassis and log record index in the event log being returned. Syntax DisplayString (SIZE (0..1024)) Access Read-only Event Log Format Name eventLogFormat Object ID 1.3.6.1.4.1.674.10892.1.300.40.1.6 Description Defines the format of the event log. Syntax DellLogFormat (See Table 6-1) Access Read-only Event Log Severity Status Name eventLogSeverityStatus Object ID 1.3.6.1.4.1.674.10892.1.300.40.1.7 Description Defines the severity of the event log record. Syntax DellStatus Access Read-only Status Mandatory 90 Chassis Information Group Event Log Date Name Name eventLogDateName Object ID 1.3.6.1.4.1.674.10892.1.300.40.1.8 Description Defines the date and time of the event log record. Syntax DellDateName Access Read-only Status Mandatory System BIOS Table This table lists objects that define the system’s basic input/output system (BIOS). Name systemBIOSTable Object ID 1.3.6.1.4.1.674.10892.1.300.50 Description Defines the System BIOS Table. Syntax SEQUENCE OF SystemBIOSTableEntry Access Not accessible System BIOS Table Entry Name systemBIOSTableEntry Object ID 1.3.6.1.4.1.674.10892.1.300.50.1 Description Defines the System BIOS Table entry. Syntax SystemBIOSTableEntry Access Not accessible Index systemBIOSchassisIndex,systemBIOSIndex System BIOS Chassis Index Name systemBIOSchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Chassis Information Group 91 Name systemBIOSchassisIndex Access Read-only System BIOS Index Name systemBIOSIndex Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.2 Description Defines the index (one-based) of the system BIOS of this object. Syntax DellObjectRange Access Read-only System BIOS State Capabilities Name systemBIOSStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.3 Description Defines the capabilities of the system BIOS of this object. Syntax DellStateCapabilities Access Read-only System BIOS State Settings Name systemBIOSStateSettings Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.4 Description Defines the state of the system BIOS of this object. Syntax DellStateSettings Access Read-write System BIOS Status Name systemBIOSStatus Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.5 Description Defines the status of the system BIOS of this object. Syntax DellStatus 92 Chassis Information Group Name systemBIOSStatus Access Read-only System BIOS Size Name systemBIOSSize Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.6 Description Defines the image size of the system BIOS in kilobytes (KB). A zero (0) indicates that the image size of the BIOS is unknown. Syntax DellUnsigned32BitRange Access Read-only System BIOS Release Date Name Name systemBIOSReleaseDateName Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.7 Description Defines the release date of the system BIOS. Syntax DellDateName Access Read-only System BIOS Version Name Name systemBIOSVersionName Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.8 Description Defines the version name of the system BIOS. Syntax DellString Access Read-only System BIOS Starting Address Name systemBIOSStartingAddress Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.9 Chassis Information Group 93 Name systemBIOSStartingAddress Description Defines the starting address of the system BIOS. A zero (0) indicates that the address is unknown. Syntax DellUnsigned64BitRange Access Read-only System BIOS Ending Address Name systemBIOSEndingAddress Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.10 Description Defines the ending address of the system BIOS. A zero (0) indicates that the address is unknown. Syntax DellUnsigned64BitRange Access Read-only System BIOS Manufacturer Name Name systemBIOSManufacturerName Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.11 Description Defines the system BIOS manufacturer’s name. Syntax DellString Access Read-only System BIOS Characteristics Name systemBIOSCharacteristics Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.12 94 Chassis Information Group Name systemBIOSCharacteristics Description Defines characteristics of the system BIOS. This attribute is a bit field where a bit has the meaning defined below when set to 1 (one). Bit 63 is the first bit in the value, and bit 0 is the last bit in the value. See the description of DellUnsigned64BitRange at the beginning of this file for more information on the format of the value. Bits 48-63 need to be examined in the context of the system ID. The system ID is available in the attribute chassisID. If the value for chassisID is non-zero, bits 48-63 have the meaning defined below: Bit Position Meaning if Set -------------- -----------------Bit 0Reserved Bit 1Reserved Bit 2Unknown Bit 3BIOS Characteristics Not Supported Bit 4ISA is supported Bit 5MCA is supported Bit 6EISA is supported Bit 7PCI is supported Bit 8PC Card (PCMCIA) is supported Bit 9Plug and Play is supported Bit 10APM is supported Bit 11BIOS is Upgradeable (Flash) Bit 12BIOS shadowing is allowed Bit 13VL-VESA is supported Bit 14ESCD support is available Bit 15Boot from CD is supported Chassis Information Group 95 Name systemBIOSCharacteristics Description Bit Position Meaning if Set -------------- -----------------Bit 16Selectable Boot is supported Bit 17BIOS ROM is socketed Bit 18Boot From PC Card (PCMCIA) is supported Bit 19EDD (Enhanced Disk Drive) Specification is supported Bit 20Int 13h - Japanese Floppy for NEC 9800 1.2mb (3.5 in, 1k Bytes/Sector, 360 RPM) is supported Bit 21Int 13h - Japanese Floppy for Toshiba 1.2mb (3.5 in, 360 RPM) is supported Bit 22Int 13h - 5.25 in / 360 KB Floppy Services are supported Bit 23Int 13h - 5.25 in /1.2MB Floppy Services are supported Bit 24Int 13h - 3.5 in / 720 KB Floppy Services are supported Bit 25Int 13h - 3.5 in / 2.88 MB Floppy Services are supported Bit 26Int 5h, Print Screen Service is supported Bit 27Int 9h, 8042 Keyboard services are supported Bit 28Int 14h, Serial Services are supported Bit 29Int 17h, Printer Services are supported Bit 30Int 10h, CGA/Mono Video Services are supported Bit 31NEC PC-98 Bit 32-47Reserved Bit 48Built-in NIC supports Magic Packet Bit 49System supports Wake-on-LAN Bit 50System supports chassis intrusion Bit 51Built-in NIC supports pattern-matching Bit 52System BIOS supports a 7-character service tag Bit 53-63Reserved Syntax DellUnsigned64BitRange System BIOS Characteristics Ext 1 Name systemBIOSCharacteristicsExt1 Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.13 96 Chassis Information Group Name systemBIOSCharacteristicsExt1 Description Defines additional characteristics of the system basic input/output system (BIOS). This attribute is a bit field where a bit has the meaning defined below when set to 1 (one). Bit Position Meaning if Set -------------- -----------------Bit 0ACPI supported Bit 1USB Legacy is supported Bit 2AGP is supported Bit 3I2O boot is supported Bit 4LS-120 boot is supported Bit 5ATAPI ZIP Drive boot is supported Bit 61394 boot is supported Bit 7Smart Battery supported Syntax DellUnsigned8BitRange Access Read-only System BIOS Characteristics Ext 2 Name systemBIOSCharacteristicsExt2 Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.14 Description Defines additional characteristics of the system BIOS. This attribute is a bit field where a bit has the meaning defined below when set to 1 (one). Bit Position Meaning if Set --------------- -------------------Bit 0BIOS Boot Specification supported Bit 1Function key-initiated Network Service boot supported Bit 2Targeted Content Distribution supported Bit 3-7Reserved Syntax DellUnsigned8BitRange Access Read-only Chassis Information Group 97 Firmware Table Name firmwareTable Object ID 1.3.6.1.4.1.674.10892.1.300.60 Description Defines the Firmware Table. Syntax SEQUENCE OF FirmwareTableEntry Access Not accessible Firmware Table Entry Name firmwareTableEntry Object ID 1.3.6.1.4.1.674.10892.1.300.60.1 Description Defines the Firmware Table entry. Syntax FirmwareTableEntry Access Not accessible Index firmwarechassisIndex, firmwareIndex Firmware Chassis Index Name firmwarechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Firmware Index Name firmwareIndex Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.2 Description Defines the index (one-based) of the firmware in this chassis. Syntax DellObjectRange Access Read-only 98 Chassis Information Group Firmware State Capabilities Name firmwareStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.3 Description Defines the capabilities of the firmware states. Syntax DellStateCapabilities Access Read-only Firmware State Capabilities Name firmwareStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.4 Description Defines the state of the firmware and allows for the setting of the firmware. Syntax DellStateSettings Access Read-write Firmware Status Name firmwareStatus Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.5 Description Defines the status of the firmware. Syntax DellStateSettings Access Read-only Firmware Size Name firmwareSize Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.6 Description Defines the image size of the firmware in KB. A zero (0) indicates that the size is unknown. Syntax DellUnsigned16BitRange Access Read-only Chassis Information Group 99 Firmware Type Name firmwareType Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.7 Description Defines the type of the firmware. Syntax DellFirmwareType Access Read-only Firmware Type Name Name firmwareTypeName Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.8 Description Defines the name of firmware type. Syntax DellString Access Read-only Firmware Update Capabilities Name firmwareUpdateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.9 Description Defines the bitmap of supported methods for firmware update. Syntax DellUnsigned16BitRange Access Read-only Firmware Date Name Name firmwareDateName Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.10 Description Defines the date of the firmware. Syntax DellDateName Access Read-only 100 Chassis Information Group Firmware Version Name Name firmwareVersionName Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.11 Description Defines the version name of the firmware. Syntax DellString Access Read-only Intrusion Table The following objects and attributes describe the different forms of chassis intrusion, a situation that occurs when the cover of a computer is removed. Name intrusionTable Object ID 1.3.6.1.4.1.674.10892.1.300.70 Description Defines the Intrusion Table. Syntax SEQUENCE OF IntrusionTableEntry Access Not accessible Intrusion Table Entry Name intrusionTableEntry Object ID 1.3.6.1.4.1.674.10892.1.300.70.1 Description Defines the Intrusion Table entry. Syntax IntrusionTableEntry Access Not accessible Index intrusionchassisIndex, intrusionIndex Intrusion Chassis Index Name intrusionchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.300.70.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Chassis Information Group 101 Intrusion Index Name intrusionIndex Object ID 1.3.6.1.4.1.674.10892.1.300.70.1.2 Description Defines the index of the intrusion objects in this subgroup. Syntax DellObjectRange Access Read-only Intrusion State Capabilities Name intrusionStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.300.70.1.3 Description Defines the capabilities of the intrusion object. Syntax DellStateCapabilities Access Read-only Intrusion State Settings Name intrusionStateSettings Object ID 1.3.6.1.4.1.674.10892.1.300.70.1.4 Description Defines the settings of the intrusion object. Syntax DellStateSettings Access Read-write Intrusion Status Name intrusionStatus Object ID 1.3.6.1.4.1.674.10892.1.300.70.1.5 Description Defines the status of the intrusion object. Syntax DellStatus Access Read-only 102 Chassis Information Group Intrusion Reading Name intrusionReading Object ID 1.3.6.1.4.1.674.10892.1.300.70.1.6 Description Defines the reading of the intrusion object. Syntax DellIntrusionReading Access Read-only Intrusion Type Name intrusionType Object ID 1.3.6.1.4.1.674.10892.1.300.70.1.7 Description Defines the type of the intrusion object. Syntax DellIntrusionType Access Read-only Intrusion Location Name Name intrusionLocationName Object ID 1.3.6.1.4.1.674.10892.1.300.70.1.8 Description Defines the location name of the intrusion object in this subgroup. Syntax DellString Access Read-only Baseboard Table This table lists objects that define the baseboard of a system. Name baseBoardTable Object ID 1.3.6.1.4.1.674.10892.1.300.80 Description Defines the Baseboard Table. Syntax SEQUENCE OF BaseBoardTableEntry Access Not accessible Chassis Information Group 103 Baseboard Table Entry Name baseBoardTableEntry Object ID 1.3.6.1.4.1.674.10892.1.300.80.1 Description Defines the Baseboard Table entry. Syntax BaseBoardTableEntry Access Not accessible Index baseBoardChassisIndex, baseBoardIndex Baseboard Chassis Index Name baseBoardChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.1 Description Defines the index (one-based) of the associated chassis. Syntax DellObjectRange Access Read-only Baseboard Index Name baseBoardIndex Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.2 Description Defines the index (one-based) of the base board. Syntax DellObjectRange Access Read-only Baseboard State Capabilities Name baseBoardStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.3 Description Defines the state capabilities of the baseboard. Syntax DellStateCapabilities Access Read-only 104 Chassis Information Group Baseboard State Settings Name baseBoardStateSettings Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.4 Description Defines the state settings of the baseboard. Syntax DellStateSettings Access Read-write Baseboard Status Name baseBoardStatus Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.5 Description Defines the status of the baseboard. Syntax DellStatus Access Read-only Baseboard Feature Flags Name baseBoardFeatureFlags Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.6 Description Defines the features of the baseboard. Syntax DellBaseBoardFeatureFlags Access Read-only Baseboard Type Name baseBoardType Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.7 Description Defines the type of the baseboard. Syntax DellBaseBoardType Access Read-only Chassis Information Group 105 Baseboard Type Name Name baseBoardTypeName Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.8 Description Defines the name of the type of baseboard. Syntax DellString Access Read-only Baseboard Location Name Name baseBoardLocationName Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.9 Description Defines the location name of the baseboard. Syntax DellString Access Read-only Baseboard Manufacturer Name Name baseBoardManufacturerName Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.10 Description Defines the baseboard manufacturer’s name. Syntax DellString Access Read-only Baseboard Product Name Name baseBoardProductName Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.11 Description Defines the baseboard product’s name. Syntax DellString Access Read-only 106 Chassis Information Group Baseboard Version Name Name baseBoardVersionName Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.12 Description Defines the baseboard version name. Syntax DellString Access Read-only Baseboard Service Tag Name Name baseBoardServiceTagName Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.13 Description Defines the baseboard service tag name. Syntax DellString Access Read-only Baseboard Piece Part ID (PPID) Name Name baseBoardPiecePartIDName Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.14 Description Defines the baseboard PPID. Syntax DellString Access Read-only Baseboard Asset Tag Name Name baseBoardAssetTagName Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.15 Description Defines the baseboard asset tag name. Syntax DellString Access Read-only Chassis Information Group 107 Baseboard Express Service Code Name Name baseBoardExpressServiceCodeName Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.16 Description Defines the express service code of the baseboard. Syntax DellString Access Read-only Chassis Information Group Variable Values This section includes definitions for server administrator-specific variable values used in this section. Table 6-1. Log Format Variable Name: DellLogFormat Data Type: Integer Possible Data Values Meaning of Data Value raw(1) The log is in the format received from the firmware. ascii(2) The log is in ASCII format. uniCode(3) The log is in Unicode format. Table 6-2. Chassis Type Variable Name: DellChassisType Data Type: Integer Possible Data Values Meaning of Data Value other(1) The chassis type is not one of the following: unknown(2) The chassis type is unknown. desktop(3) The chassis type is a desktop. lowProfileDesktop(4) The chassis type is a low-profile desktop. pizzaBox(5) The chassis type is a pizza box. miniTower(6) The chassis type is a minitower. 108 Chassis Information Group Table 6-2. Chassis Type (continued) Variable Name: DellChassisType Data Type: Integer Possible Data Values Meaning of Data Value tower(7) The chassis type is a tower. portable(8) The chassis type is a portable. lapTop(9) The chassis type is a laptop. noteBook(10) The chassis type is a notebook. handHeld(11) The chassis type is a handheld. dockingStation(12) The chassis type is a docking station. allInOne(13) The chassis type is an all-in-one. subNoteBook(14) The chassis type is a subnotebook. spaceSaving(15) The chassis type is a spacesaver. lunchBox(16) The chassis type is a lunch box. mainSystemChassis(17) The chassis type is the main system chassis. expansionChassis(18) The chassis type is an expansion chassis. subChassis(19) The chassis type is a subchassis. busExpansionChassis(20) The chassis type is a bus-expansion chassis. peripheralChassis(21) The chassis type is a peripheral chassis. raidChassis(22) The chassis type is a disk RAID chassis. rackMountChassis(23) The chassis type is a rack-mounted chassis. sealedCasePC(24) The chassis type is a sealed-case chassis. multiSystemChassis(25) The chassis type is a multisystem chassis. Chassis Information Group 109 Table 6-3. Connection Status Variable Name: DellConnectionStatus Data Type: Integer Possible Data Values Meaning of Data Value unknown(2) The status of the chassis connection is unknown. ok(3) The status of the chassis connection is OK. failure(4) The status of the chassis connection is failure. Table 6-4. Fan Control Capabilities Variable Name: DellFanControlCapabilities Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) The fan’s capabilities are unknown. lowSpeedCapable(2) The fan can be set to low speed. highSpeedCapable(4) The fan can be set to high speed. lowOrhighSpeedCapable(6) The fan can be set to low or high speed. Table 6-5. Front-Panel LED Control Capabilities Variable Name: DellLEDControlCapabilities Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) The LED control capabilities are unknown. alertOnErrorCapable(2) The LED control can be set to alert on an error condition. alertOnWarningAndErrorCap The LED control can be set to alert on an able(4) error and a warning condition. alertOnWarningOrErrorCapa The LED control can be set to alert on an ble(6) error or a warning condition. 110 Chassis Information Group Table 6-6. Front-Panel LED Control Settings Variable Name: DellLEDControlSettings Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) The LED control setting is unknown. alertOnError(2) The LED control is set to alert on an error condition. alertOnWarningAndError(4) The LED control is set to alert on an error or a warning condition. Table 6-7. Hard-Drive Fault LED Control Capabilities Variable Name: DellHDFaultLEDControlCapabilities Data Type: Integer Possible Data Values Meaning of Data Value none(0) The hard drive has no fault LED capabilities. unknownCapabilities(1) The hard-drive fault LED capabilities are unknown. enableCapable(2) The hard-drive fault LED can be disabled (offline, a binary 0 value) or enabled (online, a binary 1 value). notReadyCapable(4) The hard-drive fault LED can indicate not ready. resetCapable(8) The hard-drive fault LED can be reset. Chassis Information Group 111 Table 6-8. Hard-Drive Fault LED Control Settings Variable Name: DellHDFaultLEDControlSettings Data Type: Integer Possible Data Values Meaning of Data Value none(0) The LEDs do not have any fault settings capabilities. unknown(1) The hard-drive fault LEDs’ state is unknown. enabled(2) The hard-drive fault LEDs’ state is disabled (offline, a binary 0 value) or enabled (online, a binary 1 value). notReady(4) The hard-drive fault LEDs’ state is not ready. reset(8) The hard-drive fault LEDs have been reset. resetAndEnable(10) The hard-drive fault LEDs have been reset and enabled. Table 6-9. Chassis Identification Control Capabilities Variable Name: DellChassisIdentifyControlCapabilities Data Type: Integer Possible Data Values Meaning of Data Value none(0) The LEDs do not have any chassis identification capabilities. unknownCapabilities(1) The chassis identification control’s capabilities are unknown. enableCapable(2) The chassis identification controls can be disabled (offline, a binary 0 value) or enabled (online, a binary 1 value). notReadyCapable(4) The chassis identification control’s capabilities are not ready. identifyCapable(8) The chassis identification control’s LEDs can be made to identify the chassis. 112 Chassis Information Group Table 6-9. Chassis Identification Control Capabilities (continued) Variable Name: DellChassisIdentifyControlCapabilities Data Type: Integer Possible Data Values Meaning of Data Value NOTE: Chassis identification capabilities allow system administrators to set front panel light-emitting diodes (LEDs) to blink when the chassis has malfunctioning components. When enabled, the blinking lights help administrators locate the problem chassis. Table 6-10. Chassis Identification Control Settings Variable Name: DellChassisIdentifyControlSettings Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) The chassis identification control’s state is unknown. enabled(2) The chassis identification control’s state is disabled (offline, a binary 0 value) or enabled (online, a binary 1 value). notReady(4) The chassis identification control’s state is not ready. identifyChassis(8) The chassis identification control’s LEDs may be returned to (normal) 0, or (identify chassis) 1. identifyChassisAndEnable The chassis identification control’s (10) LEDs may be returned to normal (a binary 0 value), or identify chassis and enabled (a binary 1 value). Chassis Information Group 113 Table 6-11. Host Control Capabilities Variable Name: DellHostControlCapabilities NOTE: An operator can manually enable these actions using SNMP. Data Type: Integer Possible Data Values Meaning of Data Value manualRebootCapable(1) The operator can reboot capable host. manualPowerOFFCapable(2) The operator can power off capable host. manualPowerCycleCapable(4) The operator can power-cycle capable host. manualAllExceptOperating The operator can reboot and power off SystemShutdownCapable(7) capable host. manualOperatingSystemShut The operator can shut down the downCapable(8) operating-system–shutdown capable host. manualFullyCapable(15) The operator can reboot, power on and off the power-cycle capable host, and shut down the operating-system–shutdown capable host. manualRebootWithOSShutdow The operator can reboot with operating nCapable(16) system shutdown. manualRebootWithoutOSShut The operator can reboot without downCapable(32) operating system shutdown. manualPowerOffWithOSShutd The operator can power off with operating ownCapable(64) system shutdown. manualPowerOffWithoutOSSh The operator can power off without utdownCapable(128) operating system shutdown. manualPowerCycleWithOSShu The operator can power cycle with tdownCapable(256) operating system shutdown. manualPowerCycleWithoutOS The operator can power cycle without ShutdownCapable(512) operating system shutdown. 114 Chassis Information Group Table 6-12. Host Control Settings Variable Name: DellHostControlSettings NOTE: An operator can manually cause these actions using SNMP. Data Type: Integer Possible Data Values Meaning of Data Value manualReboot(1) The operator can reboot the host. manualPowerOFF(2) The operator can power off the host. manualPowerCycle(4) Power cycle the host. manualOperatingSystemShutdown(8) The operator can shut down the operating system on the host. manualOperatingSystemShutdownThe The operator can shut down the nPowerCycle(12) operating system on the host then power cycle machine. Table 6-13. Watchdog Control Capabilities Variable Name: DellWatchDogControlCapabilities NOTE: When the system determines that the operating system is not responding, it automatically performs the selected action without operator intervention. Data Type: Integer Possible Data Values Meaning of Data Value automaticRebootCapable(1) Watchdog controls can be set to reboot capable host. automaticPowerCycleCapable(2) Watchdog controls can be set to power cycleable capable host. automaticNotificationCapable(4) Watchdog controls can be set to notify capable host. automaticWatchDogTimerCapable(8) Watchdog controls can be set to function automatically. automaticPowerOffCapable(16) Watchdog controls can be set to automatically power off host. Chassis Information Group 115 Table 6-13. Watchdog Control Capabilities (continued) Variable Name: DellWatchDogControlCapabilities NOTE: When the system determines that the operating system is not responding, it automatically performs the selected action without operator intervention. Data Type: Integer Possible Data Values Meaning of Data Value automaticAllExceptNotificationCap Watchdog controls can be set to able(27) automatically perform all functions except notification capable. automaticFullyCapable(31) Table 6-14. Watchdog controls can be set to automatically perform all functions. Watchdog Control Settings Variable Name: DellWatchControlSettings NOTE: The watchdog timer is the mechanism used by a chassis to determine if the operating system has stopped responding. Data Type: Integer Possible Data Values Meaning of Data Value automaticRebootEnabled(1) Automatic reboot is enabled for this host. automaticPowerCycleEnabled(2) Automatic power cycleable is enabled for this host. automaticNotificationEnabled(4) Automatic notification is enabled for this host. automaticPowerOffEnabled(8) 116 Chassis Information Group Automatic power off is enabled for this host. Table 6-15. Watchdog Timer Capabilities Variable Name: DellWatchDogTimerCapabilities Data Type: Integer Possible Data Values Meaning of Data Value type1Capable(1) Watchdog timer can time in intervals from 20–480 seconds. type2Capable(2) Watchdog timer can time in 30-, 60-, 120-, and 480-second intervals. type3Capable(4) Watchdog timer can time in 60-second intervals. Table 6-16. Power Button Control Capabilities Variable Name: DellPowerButtonControlCapabilities Data Type: Integer Possible Data Values Meaning of Data Value none(0) The power button has no capabilities. unknownCapabilities(1) The power button capabilities are unknown. enableCapable(2) Table 6-17. The power button can be enabled (online) or disabled (offline). Power Button Control Settings Variable Name: DellPowerButtonControlSettings Data Type: Integer Possible Data Values Meaning of Data Value none(0) The power button has no settings capabilities. unknown(1) The power button settings are unknown. enabled(2) The power button state is enabled. disabled(4) The power button state is disabled. Chassis Information Group 117 Table 6-18. NMI Button Control Capabilities Variable Name: DellNMIButtonControlCapabilities Data Type: Integer Possible Data Values Meaning of Data Value none(0) The NMI button has no capabilities. unknownCapabilities(1) The NMI button capabilities are unknown. The NMI button can be enabled (online) or disabled (offline). enableCapable(2) Table 6-19. System Properties Variable Name: DellSystemProperties NOTE: These values are bit masks, so combination values are possible. Data Type: Integer Possible Data Values Meaning of Data Value none(0) No properties. energySmart(1) The system is an Energy Smart System. Table 6-20. NMI Button Control Settings Variable Name: DellNMIButtonControlSettings Data Type: Integer 118 Possible Data Values Meaning of Data Value none(0) The NMI button has no settings capabilities. unknown(1) The NMI button settings are unknown. enabled(2) The NMI button state is enabled. disabled(4) The NMI button state is disabled. Chassis Information Group Table 6-21. Baseboard Type Variable Name: DellBaseBoardType Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) The baseboard type is unknown. other(2) The baseboard type is not one of the following types. serverBlade(3) The baseboard type is a server blade. connectivitySwitch(4) The baseboard type is a connectivity switch. systemManagementModule(5) The baseboard type is a system management module. processorModule(6) The baseboard type is a processor module. ioModule(7) The baseboard type is an I/O module. memoryModule(8) The baseboard type is a memory module daughterBoard(9) The baseboard type is a daughter board. motherboard(10) The baseboard type is a mother board. processorMemoryModule(11) The baseboard type is a processor or memory module processorIOModule(12) The baseboard type is a processor or I/O module interconnectBoard(13) The baseboard type is an interconnect board. Table 6-22. Chassis System Class Variable Name: DellChassisSystemClass Data Type: Integer Possible Data Values Meaning of Data Value other(1) The chassis system class is not one of the following: unknown(2) The chassis system class is unknown. workstationClass(3) The chassis system class is a workstation. serverClass(4) The chassis system class is a server. Chassis Information Group 119 Table 6-22. Chassis System Class (continued) Variable Name: DellChassisSystemClass Data Type: Integer Possible Data Values Meaning of Data Value desktopClass(5) The chassis system class is a desktop. portableClass(6) The chassis system class is a portable. netPCClass(7) The chassis system class is a Net PC. storageClass(8) The chassis system class is storage. Table 6-23. Firmware Type Variable Name: DellFirmwareType Data Type: Integer Possible Data Values Meaning of Data Value other(1) The firmware type is other than following values. unknown(2) The firmware type is unknown. systemBIOS(3) The firmware type is System BIOS embeddedSystemManagementContro The firmware type is Embedded ller(4) System Management Controller. powerSupplyParallelingBoard(5) The firmware type is Power Supply Paralleling Board. systemBackPlane(6) The firmware type is System (Primary) Backplane. powerVault2XXSKernel(7) The firmware type is Dell PowerVault 2XXS Kernel. powerVault2XXSApplication(8) The firmware type is PowerVault 2XXS Application. frontPanel(9) The firmware type is Front Panel Controller. baseboardManagementController (10) The firmware type is Baseboard Management Controller. 120 Chassis Information Group Table 6-23. Firmware Type (continued) Variable Name: DellFirmwareType Data Type: Integer Possible Data Values Meaning of Data Value hotPlugPCI(11) The firmware type is Hot Plug Peripheral Component Interconnect (PCI) Controller. sensorData(12) The firmware type is Sensor Data Records. peripheralBay(13) The firmware type is Peripheral Bay Backplane. secondaryBackPlane(14) The firmware type is Secondary Backplane for ESM 2 systems. secondaryBackPlaneESM3And4(15) The firmware type is Secondary Backplane for ESM 3 and 4 systems. rac(16) The firmware type is Remote Access Controller. iDRAC(17) The firmware type is Integrated Dell Remote Access Controller. unifiedServerConfigurator(19) The firmware type is Unified Server Configurator. lifecycleController(20) The firmware type is Lifecycle Controller. Table 6-24. Baseboard Feature Flags Variable Name: DellBaseBoardFeatureFlags Data Type: Integer Possible Data Values Meaning of Data Value NOTE: These values are bit fields, so combination values are possible. no features(0) This baseboard has no feature flags. boardIsHostingBoard(1) This baseboard is a hosting board. Chassis Information Group 121 Table 6-24. Baseboard Feature Flags Variable Name: DellBaseBoardFeatureFlags Data Type: Integer Possible Data Values Meaning of Data Value boardRequiresDaughterBoard This baseboard requires at least one (2) daughter board or auxiliary card. boardIsRemovable(4) This baseboard is removable. boardIsReplaceable(8) This baseboard is replaceable. boardIsHotSwappable(16) This baseboard is hot swappable. 122 Chassis Information Group Operating System Group 7 The Operating System Group provides status and identifying information about a system’s operating system. Identifying information includes the name, version, service pack, and patch level of the installed operating system. Operating System Group Table The following management information base (MIB) tables define the objects in the Operating System Group: • "Operating System Table" on page 123 • "Operating System Memory Table" on page 125 Operating System Table The following object sets up the Operating System Table. Name operatingSystemTable Object ID 1.3.6.1.4.1.674.10892.1.400.10 Description Defines the Operating System Table. Syntax SEQUENCE OF OperatingSystemTableEntry Access Not accessible Operating System Table Entry Name operatingSystemTableEntry Object ID 1.3.6.1.4.1.674.10892.1.400.10.1 Description Defines the Operating System Table entry. Syntax OperatingSystemTableEntry Access Not accessible Index operatingSystemchassisIndex Operating System Group 123 Operating System Chassis Index Name operatingSystemchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.400.10.1.1 Description Defines the index (one-based) of the associated chassis. Syntax DellObjectRange Access Read-only Operating System State Capabilities Name operatingSystemStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.400.10.1.2 Description Defines the capabilities of the operating system. Syntax DellStateCapabilities Access Read-only Operating System State Settings Name operatingSystemStateSettings Object ID 1.3.6.1.4.1.674.10892.1.400.10.1.3 Description Defines the state of the operating system. Syntax DellStateSettings Access Read-write Operating System Status Name operatingSystemStatus Object ID 1.3.6.1.4.1.674.10892.1.400.10.1.4 Description Defines the status of the operating system. Syntax DellStatus Access Read-only 124 Operating System Group Operating System Is Primary Name operatingSystemIsPrimary Object ID 1.3.6.1.4.1.674.10892.1.400.10.1.5 Description Specifies whether this operating system is the primary operating system. Syntax DellBoolean Access Read-only Operating System Name Name operatingSystemOperatingSystemName Object ID 1.3.6.1.4.1.674.10892.1.400.10.1.6 Description Defines the name of the operating system running on the system. Syntax DisplayString (SIZE (0..255)) Access Read-only Operating System Version Name Name operatingSystemOperatingSystemVersionName Object ID 1.3.6.1.4.1.674.10892.1.400.10.1.7 Description Defines the version of the operating system running on the system. Syntax DisplayString (SIZE (0..255)) Access Read-only Operating System Memory Table Name operatingSystemMemoryTable Object ID 1.3.6.1.4.1.674.10892.1.400.20 Description Defines the Operating System Memory Table. Syntax SEQUENCE OF OperatingSystemMemoryTableEntry Access Not accessible Operating System Group 125 Operating System Memory Table Entry Name operatingSystemTableEntry Object ID 1.3.6.1.4.1.674.10892.1.400.20.1 Description Defines the Operating System Memory Table entry. Syntax OperatingSystemMemoryTableEntry Access Not accessible Index operatingSystemMemorychassisIndex Operating System Memory Chassis Index Name operatingSystemMemorychassisIndex Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Operating System Memory State Capabilities Name operatingSystemMemoryStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.2 Description Defines the capabilities of the operating system memory. Syntax DellStateCapabilities Access Read-only Operating System Memory State Settings Name operatingSystemMemoryStateSettings Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.3 Description Defines the state and allows the setting of the operating system memory. Syntax DellStateSettings Access Read-write 126 Operating System Group Operating System Memory Status Name operatingSystemMemoryStatus Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.4 Description Defines the status of the operating system memory. Syntax DellStatus Access Read-only Operating System Memory Total Physical Size Name operatingSystemMemoryTotalPhysicalSize Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.5 Description Defines the total physical memory size in kilobytes. Syntax DellUnsigned32BitRange Access Read-only Operating System Memory Available Physical Size Name operatingSystemMemoryAvailablePhysicalSize Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.6 Description Defines the available physical memory size in kilobytes. Syntax DellUnsigned32BitRange Access Read-only Operating System Memory Total Page File Size Name operatingSystemMemoryTotalPageFileSize Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.7 Description Defines the total page file memory size in kilobytes. Syntax DellUnsigned32BitRange Access Read-only Operating System Group 127 Operating System Memory Available Page File Size Name operatingSystemMemoryAvailablePageFileSize Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.8 Description Defines the available page file memory size in kilobytes. Syntax DellUnsigned32BitRange Access Read-only Operating System Memory Total Virtual Size Name operatingSystemMemoryTotalVirtualSize Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.9 Description Defines the total virtual memory size in kilobytes. Syntax DellUnsigned32BitRange Access Read-only Operating System Memory Available Virtual Size Name operatingSystemMemoryAvailableVirtualSize Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.10 Description Defines the available virtual memory size in kilobytes. Syntax DellUnsigned32BitRange Access Read-only 128 Operating System Group Operating System Group 129 130 Operating System Group System Resource Group 8 The Management Information Base (MIB) variables presented in this section enable you to track various attributes of your system resources. This section includes "System Resource Group Tables" on page 131 that track variables such as the owner, ports, system memory, interrupts, and direct memory access. System Resource Group Tables The following MIB tables define objects for the System Resource Group: • "System Resource Map Table" on page 131 • "System Resource Owner Table" on page 133 • "System Resource Input/Output (I/O) Port Table" on page 136 • "System Resource Memory Table" on page 139 • "System Resource Interrupt Table" on page 142 • "System Resource Direct Memory Access (DMA) Table" on page 145 System Resource Map Table Name systemResourceMapTable Object ID 1.3.6.1.4.1.674.10892.1.500.10 Description Defines the System Resource Map Table. Syntax SEQUENCE OF SystemResourceMapTableEntry Access Not accessible System Resource Group 131 System Resource Map Table Entry Name systemResourceMapTableEntry Object ID 1.3.6.1.4.1.674.10892.1.500.10.1 Description Defines the System Resource Map Table entry. Syntax SystemResourceMapTableEntry Access Not accessible Index systemResourceMapchassisIndex, systemResourceMapIndex System Resource Map Chassis Index Name systemResourceMapChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.500.10.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only System Resource Map Index Name systemResourceMapIndex Object ID 1.3.6.1.4.1.674.10892.1.500.10.1.2 Description Defines the index of system resource maps in this chassis. Syntax DellObjectRange Access Read-only System Resource Map State Capabilities Name systemResourceMapStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.500.10.1.3 Description Defines the capabilities of this system map. Syntax DellStateCapabilities Access Read-only 132 System Resource Group System Resource Map State Settings Name systemResourceMapStateSettings Object ID 1.3.6.1.4.1.674.10892.1.500.10.1.4 Description Defines the state and allows the setting of this system map. Syntax DellStateSettings Access Read-write System Resource Map Status Name systemResourceMapStatus Object ID 1.3.6.1.4.1.674.10892.1.500.10.1.5 Description Defines the status of this system map. Syntax DellStatus Access Read-only System Resource Map Type Name systemResourceMapType Object ID 1.3.6.1.4.1.674.10892.1.500.10.1.6 Description Defines the type of this system map. Syntax DellSystemResourceMapType (See Table 8-1) Access Read-only System Resource Owner Table Name systemResourceOwnerTable Object ID 1.3.6.1.4.1.674.10892.1.500.20 Description Defines the System Resource Owner Table. Syntax SEQUENCE OF SystemResourceOwnerTableEntry Access Not accessible System Resource Group 133 System Resource Owner Table Entry Name systemResourceOwnerTable Object ID 1.3.6.1.4.1.674.10892.1.500.20.1 Description Defines the System Resource Owner Table entry. Variables in this group reference the System Resource Map index. Syntax SystemResourceOwnerTableEntry Access Not accessible Index systemResourceOwnerchassisIndex, systemResourceOwnerIndex System Resource Owner Chassis Index Name systemResourceOwnerchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.500.20.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only System Resource Owner Index Name systemResourceOwnerIndex Object ID 1.3.6.1.4.1.674.10892.1.500.20.1.2 Description Defines the index of system resource owners for this chassis. Syntax DellObjectRange Access Read-only System Resource Owner State Capabilities Name systemResourceOwnerStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.500.20.1.3 Description Defines the capabilities of this system resource owner. Syntax DellStateCapabilities Access Read-only 134 System Resource Group System Resource Owner State Settings Name systemResourceOwnerStateSettings Object ID 1.3.6.1.4.1.674.10892.1.500.20.1.4 Description Defines the state settings of this system resource owner. Syntax DellStateSettings Access Read-write System Resource Owner Status Name systemResourceOwnerStatus Object ID 1.3.6.1.4.1.674.10892.1.500.20.1.5 Description Defines the status of this system resource owner. Syntax DellStatus Access Read-write System Resource Owner Interface Type Name systemResourceOwnerInterfaceType Object ID 1.3.6.1.4.1.674.10892.1.500.20.1.6 Description Defines the interface type for this system resource owner. Syntax DellResourceOwnerInterfaceType (See Table 8-2) Access Read-only System Resource Map Index Reference Name systemResourceMapIndexReference Object ID 1.3.6.1.4.1.674.10892.1.500.20.1.7 Description Defines the index to the associated system resource map in this chassis. Syntax DellObjectRange Access Read-only System Resource Group 135 System Resource Owner Description Name Name systemResourceOwnerDescriptionName Object ID 1.3.6.1.4.1.674.10892.1.500.20.1.8 Description Defines the description name of the system resource owner. Syntax DellString Access Read-only System Resource Owner Interface Instance Name systemResourceOwnerInterfaceInstance Object ID 1.3.6.1.4.1.674.10892.1.500.20.1.9 Description Defines the associated system resource owner interface instance in this chassis. Syntax DellObjectRange Access Read-only System Resource Input/Output (I/O) Port Table Name systemResourceIOPortTable Object ID 1.3.6.1.4.1.674.10892.1.500.30 Description Defines the System Resource I/O Port Table. Syntax SEQUENCE OF SystemResourceIOPortTableEntry Access Not accessible System Resource I/O Port Table Entry Name systemResourceIOPortTableEntry Object ID 1.3.6.1.4.1.674.10892.1.500.30.1 Description Defines the System Resource I/O Port Table entry. Syntax SystemResourceIOPortTableEntry Access Not accessible Index systemResourceIOPortchassisIndex, systemResourceIOPortIndex 136 System Resource Group System Resource I/O Port Chassis Index Name systemResourceIOPortchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.500.30.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only System Resource I/O Port Index Name systemResourceIOPortIndex Object ID 1.3.6.1.4.1.674.10892.1.500.30.1.2 Description Defines the index (one-based) of the system resource I/O ports in this chassis. Syntax DellObjectRange Access Read-only System Resource I/O Port State Capabilities Name systemResourceIOPortStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.500.30.1.3 Description Defines the capabilities of the system resource I/O port. Syntax DellStateCapabilities Access Read-only System Resource I/O Port State Settings Name systemResourceIOPortStateSettings Object ID 1.3.6.1.4.1.674.10892.1.500.30.1.4 Description Defines the state and allows the setting of the system resource I/O port. Syntax DellStateSettings Access Read-write System Resource Group 137 System Resource I/O Port Status Name systemResourceIOPortStatus Object ID 1.3.6.1.4.1.674.10892.1.500.30.1.5 Description Defines the status of the system resource I/O port. Syntax DellStateSettings Access Read-only System Resource I/O Port Owner Index Reference Name systemResourceIOPortOwnerIndexReference Object ID 1.3.6.1.4.1.674.10892.1.500.30.1.6 Description Defines the index to the associated system resource owner in this chassis. Syntax DellObjectRange Access Read-only System Resource I/O Port Share Disposition Name systemResourceIOPortShareDisposition Object ID 1.3.6.1.4.1.674.10892.1.500.30.1.7 Description Defines the share disposition of the system resource I/O port. Syntax DellResourceShareDisposition (See Table 8-3) Access Read-only System Resource I/O Port Starting Address Name systemResourceIOPortStartingAddress Object ID 1.3.6.1.4.1.674.10892.1.500.30.1.8 Description Defines the 64 bits of the starting address of the system resource I/O port. Syntax DellUnsigned64BitRange Access Read-only 138 System Resource Group System Resource I/O Port Ending Address Name systemResourceIOPortEndingAddress Object ID 1.3.6.1.4.1.674.10892.1.500.30.1.9 Description Defines the 64 bits of the ending address of the system resource I/O port. Syntax DellUnsigned64BitRange Access Read-only System Resource Memory Table Name systemResourceMemoryTable Object ID 1.3.6.1.4.1.674.10892.1.500.40 Description Defines the System Resource Memory Table. Syntax SEQUENCE OF SystemResourceMemoryTableEntry Access Not accessible System Resource Memory Table Entry Name systemResourceMemoryTableEntry Object ID 1.3.6.1.4.1.674.10892.1.500.40.1 Description Defines the System Resource Memory Table entry. Syntax SystemResourceMemoryTableEntry Access Not accessible Index systemResourceMemorychassisIndex, systemResourceMemoryIndex System Resource Memory Chassis Index Name systemResourceMemorychassisIndex Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only System Resource Group 139 System Resource Memory Index Name systemResourceMemoryIndex Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.2 Description Defines the index of system resource memory in this chassis. Syntax DellObjectRange Access Read-only System Resource Memory State Capabilities Name systemResourceMemoryStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.3 Description Defines the capabilities of this system resource memory. Syntax DellObjectRange Access Read-only System Resource Memory State Settings Name systemResourceMemoryStateSettings Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.4 Description Defines the state of this system resource memory. Syntax DellObjectRange Access Read-write System Resource Memory Status Name systemResourceMemoryStatus Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.5 Description Defines the status of this system resource memory. Syntax DellStatus Access Read-only 140 System Resource Group System Resource Memory Owner Index Reference Name systemResourceMemoryOwnerIndexReference Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.6 Description Defines the index to the associated system resource owner in this chassis. Syntax DellObjectRange Access Read-only System Resource Memory Share Disposition Name systemResourceMemoryShareDisposition Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.7 Description Defines the share disposition of the system resource memory. Syntax DellResourceShareDisposition (See Table 8-3) Access Read-only System Resource Memory Starting Address Name systemResourceMemoryStartingAddress Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.8 Description Defines the 64 bits of the starting address of the system resource memory. Syntax DellUnsigned64BitRange Access Read-only System Resource Memory Ending Address Name systemResourceMemoryEndingAddress Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.9 Description Defines the 64 bits of the ending address of the system resource memory. Syntax DellUnsigned64BitRange Access Read-only System Resource Group 141 System Resource Memory Flags Name systemResourceMemoryFlags Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.10 Description Defines the permission flags for the system resource memory. Syntax DellResourceMemoryFlags (See Table 8-4) Access Read-only System Resource Interrupt Table Name systemResourceInterruptTable Object ID 1.3.6.1.4.1.674.10892.1.500.50 Description Defines the System Resource Interrupt Table. Syntax SEQUENCE OF SystemResourceInterruptTableEntry Access Not accessible System Resource Interrupt Table Entry Name systemResourceInterruptTableEntry Object ID 1.3.6.1.4.1.674.10892.1.500.50.1 Description Defines the System Resource Interrupt Table entry. Syntax SystemResourceInterruptTableEntry Access Not accessible Index systemResourceInterruptchassisIndex, systemResourceInterruptIndex System Resource Interrupt Chassis Index Name systemResourceInterruptchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.500.50.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Not accessible 142 System Resource Group System Resource Interrupt Index Name systemResourceInterruptIndex Object ID 1.3.6.1.4.1.674.10892.1.500.50.1.2 Description Defines the index (one-based) of this interrupt resource. Syntax DellObjectRange Access Read-only System Resource Interrupt State Capabilities Name systemResourceInterruptStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.500.50.1.3 Description Defines the capabilities of this system resource interrupt. Syntax DellStateCapabilities Access Read-only System Resource Interrupt State Settings Name systemResourceInterruptStateSettings Object ID 1.3.6.1.4.1.674.10892.1.500.50.1.4 Description Defines the state of this system resource interrupt. Syntax DellStateSettings Access Read-write System Resource Interrupt Status Name systemResourceInterruptStatus Object ID 1.3.6.1.4.1.674.10892.1.500.50.1.5 Description Defines the status of this system resource interrupt. Syntax DellStatus Access Read-only System Resource Group 143 System Resource Interrupt Owner Index Reference Name systemResourceInterruptOwnerIndexReference Object ID 1.3.6.1.4.1.674.10892.1.500.50.1.6 Description Defines the index for the associated system resource owner in this chassis. Syntax DellObjectRange Access Read-only System Resource Interrupt Owner Share Disposition Name systemResourceInterruptShareDisposition Object ID 1.3.6.1.4.1.674.10892.1.500.50.1.7 Description Defines the share disposition of the system resource interrupt. Syntax DellResourceShareDisposition (See Table 8-3) Access Read-only System Resource Interrupt Level Name systemResourceInterruptLevel Object ID 1.3.6.1.4.1.674.10892.1.500.50.1.8 Description Defines the interrupt request (IRQ) level of the system resource interrupt. Syntax DellUnsigned32BitRange Access Read-only System Resource Interrupt Type Name systemResourceInterruptType Object ID 1.3.6.1.4.1.674.10892.1.500.50.1.9 Description Defines the interrupt type of the system resource interrupt. Syntax DellResourceInterruptType (See Table 8-5) Access Read-only 144 System Resource Group System Resource Interrupt Trigger Name systemResourceInterruptTrigger Object ID 1.3.6.1.4.1.674.10892.1.500.50.1.10 Description Defines the interrupt trigger of the system resource interrupt. Syntax DellResourceInterruptTrigger (See Table 8-6) Access Read-only System Resource Direct Memory Access (DMA) Table Name systemResourceDMATable Object ID 1.3.6.1.4.1.674.10892.1.500.60 Description Defines the System Resource DMA Table. Syntax SEQUENCE OF SystemResourceDMATableEntry Access Not accessible System Resource DMA Table Entry Name systemResourceDMATable Object ID 1.3.6.1.4.1.674.10892.1.500.60.1 Description Defines the System Resource DMA Table entry. Syntax SystemResourceDMATableEntry Access Not accessible Index systemResourceDMAchassisIndex, systemResourceDMAIndex System Resource DMA Chassis Index Name systemResourceDMAchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.500.60.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only System Resource Group 145 System Resource DMA Index Name systemResourceDMAIndex Object ID 1.3.6.1.4.1.674.10892.1.500.60.1.2 Description Defines the index of system resource DMAs in this chassis. Syntax DellObjectRange Access Read-only System Resource DMA State Capabilities Name systemResourceDMAStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.500.60.1.3 Description Defines the capabilities of this system resource DMA. Syntax DellStateCapabilities Access Read-only System Resource DMA State Settings Name systemResourceDMAStateSettings Object ID 1.3.6.1.4.1.674.10892.1.500.60.1.4 Description Defines the state and setting of this system resource DMA. Syntax DellStateSettings Access Read-write System Resource DMA Status Name systemResourceDMAStatus Object ID 1.3.6.1.4.1.674.10892.1.500.60.1.5 Description Defines the status of this system resource DMA. Syntax DellStatus Access Read-only 146 System Resource Group System Resource DMA Owner Index Reference Name systemResourceDMAOwnerIndexReference Object ID 1.3.6.1.4.1.674.10892.1.500.60.1.6 Description Defines the index to the associated system resource owner in this chassis. Syntax DellObjectRange Access Read-only System Resource DMA Share Disposition Name systemResourceDMAShareDisposition Object ID 1.3.6.1.4.1.674.10892.1.500.60.1.7 Description Defines the share disposition of the system resource DMA. Syntax DellResourceShareDisposition (See Table 8-3) Access Read-only System Resource DMA Maximum Transfer Size Name systemResourceDMAMaximumTransferSize Object ID 1.3.6.1.4.1.674.10892.1.500.60.1.8 Description Defines the maximum size of a memory transfer in bytes for the system resource DMA. Syntax DellUnsigned32BitRange Access Read-only System Resource DMA Transfer Width Name systemResourceDMATransferWidth Object ID 1.3.6.1.4.1.674.10892.1.500.60.1.9 Description Defines the transfer width of the system resource DMA. Syntax DellResourceDMATransferWidth (See Table 8-8) Access Read-only System Resource Group 147 System Resource DMA Bus Master Name systemResourceDMABusMaster Object ID 1.3.6.1.4.1.674.10892.1.500.60.1.10 Description Defines the bus mastering capabilities of the system resource DMA. Syntax DellResourceDMABusMaster (See Table 8-7) Access Read-only System Resource Group Variable Values This section includes definitions for server administrator-specific variable values used in this section. Table 8-1. System Resource Map Type Variable Name: DellSystemResourceMapType Data Type: Integer Possible Data Values Meaning of Data Value other(1) The system resource map type is not one of the following: unknown(2) The system resource map type is unknown (not known or not monitored). typeOne(3) The system resource map is type 1 (one). Table 8-2. Resource Owner Interface Type Variable Name: DellResourceOwnerInterfaceType Data Type: Integer Possible Data Values Meaning of Data Value typeIsOther(1) The interface type is not one of the following: typeIsUnknown(2) The interface type is unknown. typeIsInternal(3) The interface type is internal. typeIsISA(4) The interface type is an Industry Standard Architecture (ISA) bus. 148 System Resource Group Table 8-2. Resource Owner Interface Type (continued) Variable Name: DellResourceOwnerInterfaceType Data Type: Integer Possible Data Values Meaning of Data Value typeIsEISA(5) The interface type is an Extended Industry Standard Architecture (EISA) bus. typeIsMCA(6) The interface type is a microchannel architecture (MCA) bus. typeIsTurboChannel(7) The interface type is a turbo-channel bus. Table 8-3. Resource Share Disposition Variable Name: DellResourceShareDisposition Data Type: Integer Possible Data Values Meaning of Data Value shareIsOther(1) The share disposition is not one of the following: shareIsUnknown(2) The share disposition is unknown (not known or not monitored). shareIsDeviceExclusive(3) The share disposition is device exclusive. shareIsDriverExclusive(4) The share disposition is driver exclusive. shareIsShared(5) The share disposition is shared. Table 8-4. Resource Memory Flags Variable Name: DellResourceMemoryFlags Data Type: Integer Possible Data Values Meaning of Data Value memoryIsReadOnly(1) The resource memory is read-only. memoryIsWriteOnly(2) The resource memory is write-only. memoryIsPreFetchable(4) The resource memory is prefetchable. memoryIsCombinedWritable(8) The resource memory is read-write. memoryIsF24(16) The resource memory is F24. System Resource Group 149 Table 8-5. Resource Interrupt Type Variable Name: DellResourceInterruptType Data Type: Integer Possible Data Values Meaning of Data Value interruptIsLevelSensitive(1) The interrupt type is level sensitive. The interrupt type is latched. interruptIsLatched(2) Table 8-6. Resource Interrupt Trigger Variable Name: DellResourceInterruptTrigger Data Type: Integer Possible Data Values Meaning of Data Value interruptIsActiveWhenLow(1) The interrupt trigger is active on a low signal. interruptIsActiveWhenHigh(2) The interrupt trigger is active on a high signal. Table 8-7. Resource DMA Bus Master Variable Name: DellResourceDMABusMaster Data Type: Integer Possible Data Values Meaning of Data Value dmaIsOther(1) The DMA bus master capability is not one of the following: dmaIsUnknown(2) The DMA bus master capability is unknown. dmaIsNotABusmaster(3) The DMA does not have bus master capability. 150 System Resource Group Table 8-8. Resource DMA Transfer Width Variable Name: DellResourceDMATransferWidth Data Type: Integer Possible Data Values Meaning of Data Value dmaTransferWidthIsOther(1) The DMA transfer width is not one of the following: dmaTransferWidthIsunknown(2) The DMA transfer width is unknown. dmaTransferWidthIs8Bits(3) The DMA transfer width is 8 bits. dmaTransferWidthIs16Bits(4) The DMA transfer width is 16 bits. dmaTransferWidthIs32Bits(5) The DMA transfer width is 32 bits. dmaTransferWidthIs64Bits(6) The DMA transfer width is 64 bits. dmaTransferWidthIs128Bits(7) The DMA transfer width is 128 bits. System Resource Group 151 152 System Resource Group 9 Power Group The Power Group provides information about power units (a group of power supplies in a system chassis), power supplies, and voltage and amperage probes. NOTE: Power Management features are only available for PowerEdge systems that have hot-swappable power supplies and not systems that have a fixed, nonredundant power supply installed. Power Group Tables The following management information base (MIB) tables define objects for the Power Group: • "Power Unit Table" on page 153 • "Power Supply Table" on page 156 • "Voltage Probe Table" on page 160 • "Amperage Probe Table" on page 165 • "AC Power Switch Table" on page 171 • "AC Power Cord Table" on page 173 • "Battery Table" on page 176 • "Power Usage Table" on page 178 • "Power Profile Table" on page 184 Power Unit Table Name powerUnitTable Object ID 1.3.6.1.4.1.674.10892.1.600.10 Description Defines the Power Unit Table. Syntax PowerUnitTableEntry Access Not accessible Power Group 153 Power Unit Table Entry Name powerUnitTableEntry Object ID 1.3.6.1.4.1.674.10892.1.600.10.1 Description Defines the Power Unit Table entry. Syntax DellObjectRange Access Read-only Index powerUnitchassisIndex, powerUnitIndex Power Unit Chassis Index Name powerUnitchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.600.10.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Power Unit Index Name powerUnitIndex Object ID 1.3.6.1.4.1.674.10892.1.600.10.1.2 Description Defines the index of the power unit in this chassis. Syntax DellObjectRange Access Read-only Power Unit State Capabilities Name powerUnitStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.600.10.1.3 Description Defines the capabilities of the power unit. Syntax DellStateCapabilities Access Read-only 154 Power Group Power Unit State Settings Name powerUnitStateSettings Object ID 1.3.6.1.4.1.674.10892.1.600.10.1.4 Description Defines the state and settings of the power unit. Syntax DellStateSettings Access Read-write Power Unit Redundancy Status Name powerUnitRedundancyStatus Object ID 1.3.6.1.4.1.674.10892.1.600.10.1.5 Description Defines the redundancy status of the power unit. Syntax DellStatusRedundancy Access Read-only Power Supply Count for Redundancy Name powerSupplyCountForRedundancy Object ID 1.3.6.1.4.1.674.10892.1.600.10.1.6 Description Defines the total number of power supplies required for this power unit to have redundancy. Syntax DellString Access Read-only Power Unit Name Name powerUnitName Object ID 1.3.6.1.4.1.674.10892.1.600.10.1.7 Description Defines the name of the power unit in this chassis. Syntax DellString Access Read-only Power Group 155 Power Unit Status Name powerUnitStatus Object ID 1.3.6.1.4.1.674.10892.1.600.10.1.8 Description Defines the status of the power unit in this chassis. Syntax DellStatus Access Read-only Power Supply Table Name powerSupplyTable Object ID 1.3.6.1.4.1.674.10892.1.600.12 Description Defines the Power Supply Table. Syntax PowerSupplyTableEntry Access Not accessible Power Supply Table Entry Name powerSupplyTableEntry Object ID 1.3.6.1.4.1.674.10892.1.600.12.1 Description Defines the Power Supply Table entry. Syntax PowerSupplyTableEntry Access Not accessible Index powerSupplychassisIndex, powerSupplyIndex Power Supply Chassis Index Name powerSupplychassisIndex Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only 156 Power Group Power Supply Index Name powerSupplyIndex Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.2 Description Defines the index of power supply. Syntax DellObjectRange Access Read-only Power Supply State Capabilities Unique Name powerSupplyStateCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.3 Description Defines the capabilities of the power supply. Syntax DellPowerSupplyStateCapabilitiesUnique (See Table 9-1) Access Read-only Power Supply State Settings Unique Name powerSupplyStateSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.4 Description Defines the state and settings of the power supply. Syntax DellPowerSupplyStateSettingsUnique (See Table 9-2) Access Read-write Power Supply Status Name powerSupplyStatus Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.5 Description Defines the status of the power supply. Syntax DellStatus Access Read-only Power Group 157 Power Supply Output Watts Name powerSupplyOutputWatts Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.6 Description Defines the maximum sustained output wattage of the power supply in tenths of watts. Syntax DellSigned32BitRange Access Read-only Power Supply Type Name powerSupplyType Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.7 Description Defines the type of power supply. Syntax DellPowerSupplyType (See Table 9-3) Access Read-only Power Supply Location Name Name powerSupplyLocationName Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.8 Description Defines the location name of the power supply. Syntax DellString Access Read-only Power Supply Input Voltage Name powerSupplyInputVoltage Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.9 Description Defines the input voltage to the power supply in volts. Syntax DellSigned32BitRange Access Read-only 158 Power Group Power Supply Power Unit Index Reference Name powerSupplypowerUnitIndexReference Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.10 Description Defines the index to the associated system power unit in this chassis. Syntax DellObjectRange Access Read-only Power Supply Sensor State Name powerSupplySensorState Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.11 Description Defines the state reported by the power supply sensor, and supplements the state and settings of the power supply. Syntax DellPowerSupplySensorState (See Table 9-4) Access Read-only Power Supply Configuration Error Type Name powerSupplyConfigurationErrorType Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.12 Description Defines the type of configuration error reported by the power supply sensor. Syntax DellPowerSupplyConfigurationErrorType (See Table 9-5) Access Read-only Power Supply Power Monitor Capable Name powerSupplyPowerMonitorCapable Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.13 Description Defines a boolean value that reports whether the power supply is capable of monitoring power consumption. Syntax DellBoolean Access Read-only Power Group 159 Power Supply Rated Input Wattage Name powerSupplyRatedInputWattage Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.14 Description Defines the rated input wattage of the power supply (in tenths of Watts.) Syntax DellSigned32BitRange Access Read-only Voltage Probe Table Name voltageProbeTable Object ID 1.3.6.1.4.1.674.10892.1.600.20 Description Defines the Voltage Probe Table. Syntax VoltageProbeTableEntry Access Not accessible Voltage Probe Table Entry Name voltageProbeTableEntry Object ID 1.3.6.1.4.1.674.10892.1.600.20.1 Description Defines the Voltage Probe Table entry. Syntax VoltageProbeTableEntry Access Not accessible Index voltageProbechassisIndex, voltageProbeIndex Voltage Probe Chassis Index Name voltageProbechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only 160 Power Group Voltage Probe Index Name voltageProbeIndex Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.2 Description Defines the index of voltage probes in this chassis. Syntax DellObjectRange Access Read-only Voltage Probe State Capabilities Name voltageProbeStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.3 Description Defines the capabilities of the voltage probe. Syntax DellStateCapabilities Access Read-only Voltage Probe State Settings Name voltageProbeStateSettings Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.4 Description Defines the state and settings of the voltage probe. Syntax DellStateSettings Access Read-write Voltage Probe Status Name voltageProbeStatus Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.5 Description Defines the status of the voltage probe. Syntax DellStatusProbe Access Read-only Power Group 161 Voltage Probe Reading Name voltageProbeReading Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.6 Description Defines the value of the voltage probe reading. The value is an integer representing the voltage in millivolts that the probe is reading. When the value for voltageProbeType is voltageProbeTypeIsDiscrete, a value is not returned for this attribute. Syntax DellSigned32BitRange Access Read-only Voltage Probe Type Name voltageProbeType Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.7 Description Defines the type of the voltage probe. Syntax DellVoltageType Access Read-only Voltage Probe Location Name Name voltageProbeLocationName Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.8 Description Defines the location of the voltage probe in this chassis. Syntax DellString Access Read-only Voltage Probe Upper Nonrecoverable Threshold Name voltageProbeUpperNonRecoverableThreshold Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.9 Description Defines the value of the voltage probe’s upper nonrecoverable threshold. Syntax DellSigned32BitRange 162 Power Group Name voltageProbeUpperNonRecoverableThreshold Access Read-only Voltage Probe Upper Critical Threshold Name voltageProbeUpperCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.10 Description Defines the value of the voltage probe’s upper critical threshold. Syntax DellSigned32BitRange Access Read-only Voltage Probe Upper Noncritical Threshold Name voltageProbeUpperNonCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.11 Description Defines the user-assigned value of the voltage probe’s upper noncritical threshold. Syntax DellSigned32BitRange Access Read-write Voltage Probe Lower Noncritical Threshold Name voltageProbeLowerNonCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.12 Description Defines the user-assigned value of the voltage probe’s lower noncritical threshold. Syntax DellSigned32BitRange Access Read-write Power Group 163 Voltage Probe Lower Critical Threshold Name voltageProbeLowerCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.13 Description Defines the value of the voltage probe’s lower critical threshold. Syntax DellSigned32BitRange Access Read-only Voltage Probe Lower Nonrecoverable Threshold Name voltageProbeLowerNonRecoverableThreshold Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.14 Description Defines the value of the voltage probe’s lower nonrecoverable threshold. Syntax DellSigned32BitRange Access Read-only Voltage Probe Probe Capabilities Name voltageProbeProbeCapabilities Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.15 Description Defines the probe capabilities of the voltage probe. Syntax DellProbeCapabilities Access Read-only 164 Power Group Voltage Probe Discrete Reading Name voltageProbeDiscreteReading Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.16 Description Defines the reading for a voltage probe of type voltageProbeTypeIsDiscrete. When the value for voltageProbeType is other than voltageProbeTypeIsDiscrete, a value is not returned for this attribute. When the value for voltageProbeType is voltageProbeTypeIsDiscrete, the value returned for this attribute is the discrete reading for the probe. Syntax DellVoltageDiscreteReading Access Read-only Amperage Probe Table Name amperageProbeTable Object ID 1.3.6.1.4.1.674.10892.1.600.30 Description Defines the Amperage Probe Table. Syntax SEQUENCE OF AmperageProbeTableEntry Access Not accessible Amperage Probe Table Entry Name amperageProbeTableEntry Object ID 1.3.6.1.4.1.674.10892.1.600.30.1 Description Defines the Amperage Probe Table entry. Syntax AmperageProbeTableEntry Access Not accessible Index amperageProbechassisIndex, amperageProbeIndex Power Group 165 Amperage Probe Chassis Index Name amperageProbechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Amperage Probe Index Name amperageProbeIndex Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.2 Description Defines the index of amperage probes in this chassis. Syntax DellObjectRange Access Read-only Amperage Probe State Capabilities Name amperageProbeStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.3 Description Defines the capabilities of the amperage probe. Syntax DellStateCapabilities Access Read-only Amperage Probe State Settings Name amperageProbeStateSettings Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.4 Description Defines the state and settings of the amperage probe. Syntax DellStateSettings Access Read-write 166 Power Group Amperage Probe Status Name amperageProbeStatus Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.5 Description Defines the status of the amperage probe. Syntax DellSigned32BitRange Access Read-only Amperage Probe Reading Name amperageProbeReading Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.6 Description Defines the reading for an amperage probe of type other than amperageProbeTypeIsDiscrete. When the value for amperageProbeType is amperageProbeTypeIsPowerSupplyAmps or amperageProbeTypeIsSystemAmps, the value returned for this attribute is the power usage that the probe is reading in tenths of Amperes. When the value for amperageProbeType is amperageProbeTypeIsPowerSupplyWatts or amperageProbeTypeIsSystemWatts, the value returned for this attribute is the power usage that the probe is reading in Watts. When the value for amperageProbeType is other than amperageProbeTypeIsDiscrete, amperageProbeTypeIsPowerSupplyAmps, amperageProbeTypeIsPowerSupplyWatts, amperageProbeTypeIsSystemAmps, or amperageProbeTypeIsSystemWatts, the value returned for this attribute is the amperage that the probe is reading in Milliamps. When the value for amperageProbeType is amperageProbeTypeIsDiscrete, a value is not returned for this attribute. Syntax DellSigned32BitRange Access Read-only Power Group 167 Amperage Probe Type Name amperageProbeType Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.7 Description Defines the type of the amperage probe. Syntax DellAmperageProbeType Access Read-only Amperage Probe Location Name Name amperageProbeLocationName Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.8 Description Defines the location name of the amperage probe in this chassis. Syntax DellString Access Read-only Amperage Probe Upper Nonrecoverable Threshold Name amperageProbeUpperNonRecoverableThreshold Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.9 Description Defines the value of the amperage probe’s upper nonrecoverable threshold. The value is an integer representing the amperage in milliamperes that the probe is reading. Syntax DellSigned32BitRange Access Read-only Amperage Probe Upper Critical Threshold Name amperageProbeUpperCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.10 Description Defines the value of the amperage probe’s upper critical threshold. Syntax DellSigned32BitRange Access Read-only 168 Power Group Amperage Probe Upper Noncritical Threshold Name amperageProbeUpperNonCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.11 Description Defines the user-assigned value of the amperage probe’s upper critical threshold. Syntax DellSigned32BitRange Access Read-write Amperage Probe Lower Noncritical Threshold Name amperageProbeLowerNonCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.12 Description Defines the user-assigned value of the amperage probe’s lower noncritical threshold. Syntax DellSigned32BitRange Access Read-write Amperage Probe Lower Critical Threshold Name amperageProbeLowerCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.13 Description Defines the value of the amperage probe’s lower critical threshold. Syntax DellSigned32BitRange Access Read-only Power Group 169 Amperage Probe Lower Nonrecoverable Threshold Name amperageProbeLowerNonRecoverableThreshold Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.14 Description Defines the value of the amperage probe’s lower nonrecoverable threshold. Syntax DellSigned32BitRange Access Read-only Amperage Probe Probe Capabilities Name amperageProbeProbeCapabilities Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.15 Description Defines the probe capabilities of the amperage probe. Syntax DellProbeCapabilities Access Read-only Amperage Probe Discrete Reading Name amperageProbeDiscreteReading Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.16 Description Defines the reading for a amperage probe of type amperageProbeTypeIsDiscrete. When the value for amperageProbeType is other than amperageProbeTypeIsDiscrete, a value is not returned for this attribute. When the value for amperageProbeType is amperageProbeTypeIsDiscrete, the value returned for this attribute is the discrete reading for the probe. Syntax DellAmperageDiscreteReading (See Table 9-9) Access Read-only 170 Power Group AC Power Switch Table Name aCPowerSwitchTable Object ID 1.3.6.1.4.1.674.10892.1.600.40 Description Defines the AC Power Switch Table. Syntax SEQUENCE OF ACPowerSwitchTableEntry Access Not accessible AC Power Switch Table Entry Name aCPowerSwitchTableEntry Object ID 1.3.6.1.4.1.674.10892.1.600.40.1 Description Defines the AC Power Switch Table entry. Syntax ACPowerSwitchTableEntry Access Not accessible Index aCPowerSwitchchassisIndex, aCPowerSwitchIndex AC Power Switch Chassis Index Name aCPowerSwitchChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.600.40.1.1 Description Defines the index (one-based) of the chassis containing this AC power switch. Syntax DellObjectRange Access Read-only AC Power Switch Index Name aCPowerSwitchIndex Object ID 1.3.6.1.4.1.674.10892.1.600.40.1.2 Description Defines the index (one-based) of this AC power switch. Syntax DellObjectRange Access Read-only Power Group 171 AC Power Switch Capabilities Name aCPowerSwitchCapabilities Object ID 1.3.6.1.4.1.674.10892.1.600.40.1.3 Description Defines the capabilities of this AC power switch. Syntax DellACPowerSwitchCapabilities Access Read-only AC Power Switch Settings Name aCPowerSwitchSettings Object ID 1.3.6.1.4.1.674.10892.1.600.40.1.4 Description Defines the settings of this AC power switch. Syntax DellACPowerSwitchSettings Access Read-write AC Power Switch Redundancy Status Name aCPowerSwitchRedundancyStatus Object ID 1.3.6.1.4.1.674.10892.1.600.40.1.5 Description Defines the redundancy status of this AC power switch. Syntax DellStatusRedundancy Access Read-only AC Power Cord Count for Redundancy Name aCPowerCordCountForRedundancy Object ID 1.3.6.1.4.1.674.10892.1.600.40.1.6 Description Defines the total number of AC power cords required for this AC power switch to have redundancy. Syntax DellObjectRange Access Read-only 172 Power Group AC Power Switch Name Name aCPowerSwitchName Object ID 1.3.6.1.4.1.674.10892.1.600.40.1.7 Description Defines the name of this AC power switch. Syntax DellString Access Read-only AC Power Switch Redundancy Mode Name aCPowerSwitchRedundancyMode Object ID 1.3.6.1.4.1.674.10892.1.600.40.1.8 Description Defines the redundancy mode of this AC power switch. Syntax DellACPowerSwitchRedundancyMode Access Read-write AC Power Switch Status Name aCPowerSwitchStatus Object ID 1.3.6.1.4.1.674.10892.1.600.40.1.9 Description Defines the status of this AC power switch. Syntax DellStatus Access Read-only AC Power Cord Table Name aCPowerCordTable Object ID 1.3.6.1.4.1.674.10892.1.600.42 Description Defines the AC Power Cord Table. Syntax SEQUENCE OF ACPowerCordTableEntry Access Not accessible Power Group 173 AC Power Cord Table Entry Name aCPowerCordTableEntry Object ID 1.3.6.1.4.1.674.10892.1.600.42.1 Description Defines the AC Power Cord Table entry. Syntax ACPowerCordTableEntry Access Not accessible Index aCPowerCordchassisIndex, aCPowerCordIndex AC Power Cord Chassis Index Name aCPowerCordChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.600.42.1.1 Description Defines the index (one-based) of the chassis containing this AC power cord. Syntax DellObjectRange Access Read-only AC Power Cord Index Name aCPowerCordIndex Object ID 1.3.6.1.4.1.674.10892.1.600.42.1.2 Description Defines the index (one-based) of this AC power cord. Syntax DellObjectRange Access Read-only AC Power Cord State Capabilities Name aCPowerCordStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.600.42.1.3 Description Defines the capabilities of this AC power cord. Syntax DellACPowerCordStateCapabilities Access Read-only 174 Power Group AC Power Cord State Settings Name aCPowerCordStateSettings Object ID 1.3.6.1.4.1.674.10892.1.600.42.1.4 Description Defines the settings of this AC power cord. Syntax DellACPowerCordStateSettings Access Read-write AC Power Cord Status Name aCPowerCordStatus Object ID 1.3.6.1.4.1.674.10892.1.600.42.1.5 Description Defines the status of this AC power cord. Syntax DellStatus Access Read-only AC Power Cord AC Power Switch Index Reference Name aCPowerCordaCPowerSwitchIndexReference Object ID 1.3.6.1.4.1.674.10892.1.600.42.1.6 Description Defines the index (one-based) to the associated AC power switch for this AC power cord. Syntax DellObjectRange Access Read-only AC Power Cord Location Name Name aCPowerCordLocationName Object ID 1.3.6.1.4.1.674.10892.1.600.42.1.7 Description Defines the location name of this AC power cord. Syntax DellString Access Read-only Power Group 175 Battery Table Name batteryTable Object ID 1.3.6.1.4.1.674.10892.1.600.50 Description Defines the Battery Table. Syntax SEQUENCE OF BatteryTableEntry Access Not accessible Battery Table Entry Name batteryTableEntry Object ID 1.3.6.1.4.1.674.10892.1.600.50.1 Description Defines the Battery Table Entry. Syntax BatteryTableEntry Access Not accessible Index batteryChassisIndex, batteryIndex Battery Chassis Index Name batteryChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.600.50.1.1 Description Defines the index (one-based) of the chassis that contains the battery. Syntax DellObjectRange Access Read-only Battery Index Name batteryIndex Object ID 1.3.6.1.4.1.674.10892.1.600.50.1.2 Description Defines the index (one-based) of the battery. Syntax DellObjectRange Access Read-only 176 Power Group Battery State Capabilities Name batteryStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.600.50.1.3 Description Defines the state capabilities of the battery. Syntax DellStateCapabilities Access Read-only Battery State Settings Name batteryStateSettings Object ID 1.3.6.1.4.1.674.10892.1.600.50.1.4 Description Defines the state settings of the battery. Syntax DellStateSettings Access Read-write Battery Status Name batteryStatus Object ID 1.3.6.1.4.1.674.10892.1.600.50.1.5 Description Defines the status of the battery. Syntax DellStatus Access Read-only Battery Reading Name batteryReading Object ID 1.3.6.1.4.1.674.10892.1.600.50.1.6 Description Defines the reading of the battery. Syntax DellBatteryReading (see Table 9-15) Access Read-only Power Group 177 Battery Location Name Name batteryLocationName Object ID 1.3.6.1.4.1.674.10892.1.600.50.1.7 Description Defines the location of the battery. Syntax DellString Access Read-only Power Usage Table Name powerUsageTable Object ID 1.3.6.1.4.1.674.10892.1.600.60 Description Defines the Power Usage Table. Syntax SEQUENCE OF PowerUsageTableEntry Access Not accessible Power Usage Table Entry Name powerUsageTableEntry Object ID 1.3.6.1.4.1.674.10892.1.600.60.1 Description Defines the Power Usage Table Entry. Syntax PowerUsageTableEntry Access Not accessible Index powerUsageChassisIndex, powerUsageIndex Power Usage Chassis Index Name powerUsageChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.1 Description Defines the index (one-based) of the associated chassis. Syntax DellObjectRange Access Read-only 178 Power Group Power Usage Index Name powerUsageIndex Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.2 Description Defines the index (one-based) of the power usage information. Syntax DellObjectRange Access Read-only Power Usage State Capabilities Name powerUsageStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.3 Description Defines the state capabilities of the power usage information. Syntax DellStateCapabilities Access Read-only Power Usage State Settings Name powerUsageStateSettings Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.4 Description Defines the state settings of the power usage information. Syntax DellStateSettings Access Read-write Power Usage Status Name powerUsageStatus Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.5 Description Defines the status of the power usage information. Syntax DellStatus Access Read-only Power Group 179 Power Usage Entity Name Name powerUsageEntityName Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.6 Description Defines the name of the entity associated with this power usage information. Syntax DellString Access Read-only Power Usage Cumulative Wattage Name powerUsageCumulativeWattage Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.7 Description Defines the total wattage used (in Watt-hours) by this entity since the date and time specified by the powerUsageCumulativeWattageStartDateName attribute. Syntax DellUnsigned32BitRange Access Read-only Power Usage Cumulative Wattage Start Date Name Name powerUsageCumulativeWattageStartDateName Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.8 Description Defines the date and time at which the data collection started for the value reported by the powerUsageCumulativeWattage attribute. Syntax DellDateName Access Read-only Power Usage Peak Watts Name powerUsagePeakWatts Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.9 180 Power Group Name powerUsagePeakWatts Description Defines the peak wattage reading (in Watts) for this entity since the date and time specified by the powerUsagePeakWattsStartDateName attribute. Syntax DellUnsigned32BitRange Access Read-only Power Usage Peak Watts Start Date Name Name powerUsagePeakWattsStartDateName Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.10 Description Defines the date and time at which the data collection started for the value reported by the powerUsagePeakWatts attribute. Syntax DellDateName Access Read-only Power Usage Peak Watts Reading Date Name Name powerUsagePeakWattsReadingDateName Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.11 Description Defines the date and time at which the value reported by the powerUsagePeakWatts attribute was measured. Syntax DellDateName Access Read-only Power Usage Peak Amps Name powerUsagePeakAmps Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.12 Description Defines the peak amperage reading (in tenths of Amps) for this entity since the date and time specified by the powerUsagePeakAmpsStartDateName attribute. Syntax DellUnsigned32BitRange Access Read-only Power Group 181 Power Usage Peak Amps Start Date Name Name powerUsagePeakAmpsStartDateName Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.13 Description Defines the date and time at which the data collection started for the value reported by the powerUsagePeakAmps attribute. Syntax DellDateName Access Read-only Power Usage Peak Amps Reading Date Name Name powerUsagePeakAmpsReadingDateName Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.14 Description Defines the date and time at which the value reported by the powerUsagePeakAmps attribute was measured. Syntax DellDateName Access Read-only Power Usage Idle Power Name powerUsageIdlePower Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.15 Description Defines the system idle power (in Watts). This is the minimum power the system can consume based on the current hardware configuration. Syntax DellUnsigned32BitRange Access Read-only Power Usage Max Potential Power Name powerUsageMaxPotentialPower Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.16 182 Power Group Name powerUsageMaxPotentialPower Description Defines the maximum potential power (in Watts) of the system. This is the maximum power the system can consume based on the current hardware configuration. Syntax DellUnsigned32BitRange Access Read-only Power Usage Power Cap Capabilities Name powerUsagePowerCapCapabilities Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.17 Description Defines the system power cap capabilities. Syntax DellPowerCapCapabilities Access Read-only Power Usage Power Cap Setting Name powerUsagePowerCapSetting Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.18 Description Defines the system power cap setting. Syntax DellPowerCapSetting Access Read-only Power Usage Power Cap Value Name powerUsagePowerCapValue Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.19 Description Defines the system power cap value (in Watts). Syntax DellUnsigned32BitRange Access Read-only Power Group 183 Power Usage Instantaneous Headroom Name powerUsageInstantaneousHeadroom Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.20 Description Defines the system instantaneous headroom (in Watts). This is the theoretical maximum power drawn by the power supply minus instantaneous power draw. Syntax DellUnsigned32BitRange Access Read-only Power Usage Peak Headroom Name powerUsagePeakHeadroom Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.21 Description Defines the system peak headroom (in Watts). This is the theoretical maximum power drawn by the power supply minus peak power draw. Syntax DellUnsigned32BitRange Access Read-only Power Profile Table Name powerProfileTable Object ID 1.3.6.1.4.1.674.10892.1.600.70 Description Defines the Power Profile Table. Syntax SEQUENCE OF PowerProfileTableEntry Access Not accessible Power Profile Table Entry Name powerProfileTableEntry Object ID 1.3.6.1.4.1.674.10892.1.600.70.1 Description Defines the Power Profile Table Entry. Syntax PowerProfileTableEntry 184 Power Group Name powerProfileTableEntry Access Not accessible Index powerProfileChassisIndex, powerProfileIndex Power Profile Chassis Index Name powerProfileChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.600.70.1.1 Description Defines the index (one-based) of the associated chassis. Syntax DellObjectRange Access Read-only Power Profile Index Name powerProfileIndex Object ID 1.3.6.1.4.1.674.10892.1.600.70.1.2 Description Defines the index (one-based) of the power profile information. Syntax DellObjectRange Access Read-only Power Profile Supported Profiles Name powerProfileSupportedProfiles Object ID 1.3.6.1.4.1.674.10892.1.600.70.1.3 Description Defines the supported power profiles. Syntax DellPowerProfileType Access Read-only Power Profile Setting Name powerProfileSetting Object ID 1.3.6.1.4.1.674.10892.1.600.70.1.4 Description Defines the power profile setting. Power Group 185 Name powerProfileSetting Syntax DellPowerProfileType Access Read-only Power Profile Custom CPU Management Capabilities Name powerProfileCustomCPUManagementCapabilities Object ID 1.3.6.1.4.1.674.10892.1.600.70.1.5 Description Defines the custom CPU power and performance management capabilities that are available for the Custom power profile. Syntax DellCPUPowerPerformanceManagementType Access Read-only Power Profile Custom CPU Management Setting Name powerProfileCustomCPUManagementSetting Object ID 1.3.6.1.4.1.674.10892.1.600.70.1.6 Description Defines the custom CPU power and performance management setting for the Custom power profile. Syntax DellCPUPowerPerformanceManagementType Access Read-only Power Profile Custom Memory Management Capabilities Name powerProfileCustomMemoryManagementCapabiliti es Object ID 1.3.6.1.4.1.674.10892.1.600.70.1.7 Description Defines the custom memory power and performance management capabilities that are available for the Custom power profile. Syntax DellMemoryPowerPerformanceManagementType Access Read-only 186 Power Group Power Profile Custom Memory Management Setting Name powerProfileCustomMemoryManagementSetting Object ID 1.3.6.1.4.1.674.10892.1.600.70.1.8 Description Defines the custom memory power and performance management setting for the Custom power profile. Syntax DellMemoryPowerPerformanceManagementType Access Read-only Power Profile Custom Fan Management Capabilities Name powerProfileCustomFanManagementCapabilities Object ID 1.3.6.1.4.1.674.10892.1.600.70.1.9 Description Defines the custom fan power and performance management capabilities that are available for the Custom power profile. Syntax DellFanPowerPerformanceManagementType Access Read-only Power Profile Custom Fan Management Setting Name powerProfileCustomFanManagementSetting Object ID 1.3.6.1.4.1.674.10892.1.600.70.1.10 Description Defines the custom fan power and performance management setting for the Custom power profile. Syntax DellFanPowerPerformanceManagementType Access Read-only Power Group Variable Values This section includes definitions for server administrator-specific variable values used in this section. Power Group 187 Table 9-1. Power Supply State Capabilities Unique Variable Name: DellPowerSupplyStateCapabilitiesUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) The power supply’s capabilities are unknown. onlineCapable(2) The power supply can be disabled (offline, a binary 0 value) or enabled (online, a binary 1 value). notReadyCapable(4) The power supply’s capabilities are not ready. Table 9-2. Power Supply State Settings Unique Variable Name: DellPowerSupplyStateSettingsUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) The power supply’s capabilities are unknown. onLine(2) The power supply’s state is disabled (offline, a binary 0 value) or enabled (online, a binary 1 value). notReady(4) The power supply’s state is not ready. fanFailure(8) The power supply fan has failed. onlineAndFanFailure(10) The power supply is online and indicating that its fan is not working. powerSupplyIsON(16) The power supply is indicating that it is on. powerSupplyIsOk(32) The power supply is indicating that it is OK. acSwitchIsON(64) The power supply is indicating that the AC power switch is on. onlineandAcSwitchIsON The power supply is online and indicating that the (66) AC power supply switch capability is activated. acPowerIsON(128) The power supply is indicating that the AC power is on. onlineAndAcPowerIsON (130) The power supply is online and indicating that the AC power is on. 188 Power Group Table 9-2. Power Supply State Settings Unique (continued) Variable Name: DellPowerSupplyStateSettingsUnique Data Type: Integer Possible Data Values Meaning of Data Value onlineAndPredictiveFail The power supply is online and indicating that it ure(210) has a problem. acPowerAndSwitchAreOn The power supply is online and OK. PowerSupplyIsOnIsOkAnd Online(242) Table 9-3. Power Supply Type Definitions Variable Name: DellPowerSupplyType Data Type: Integer Possible Data Values Meaning of Data Value powerSupplyTypeIsOther(1) The power supply type is not one of the following: powerSupplyTypeIsUnknown(2) The power supply type is unknown (not known or not monitored). powerSupplyTypeIsLinear(3) The power supply type is a linear power supply. powerSupplyTypeIsSwitching(4) The power supply type is a switching power supply. powerSupplyTypeIsBattery(5) The power supply type is a battery. powerSupplyTypeIsUPS(6) The power supply type is an uninterruptable power supply. powerSupplyTypeIsConverter(7) The power supply type is a power converter power supply. powerSupplyTypeIsRegulator(8) The power supply type is a regulator power supply. powerSupplyTypeIsAC(9) The power supply type is an AC power supply. Power Group 189 Table 9-3. Power Supply Type Definitions (continued) Variable Name: DellPowerSupplyType Data Type: Integer Possible Data Values Meaning of Data Value powerSupplyTypeIsDC(10) The power supply type is a DC power supply. powerSupplyTypeIsVRM(11) The power supply type is a voltage regulator module (VRM) power supply. Table 9-4. Power Supply Sensor State Variable Name: DellPowerSupplySensorState Data Type: Integer Possible Data Values Meaning of Data Value presenceDetected(1) The power supply’s presence is detected. psFailureDetected(2) The power supply failure is detected. predictiveFailure(4) The power supply sensor detects predictive failure psACLost(8) The power supply’s AC power is lost. acLostOrOutOfRange(16) The power supply’s AC power is lost or out of range. acOutOfRangeButPresent(32) The power supply’s AC power is present, but it is out of range. configurationError(64) 190 Power Group The power supply sensor detects a configuration error. Table 9-5. Power Supply Configuration Error Type Variable Name: DellPowerSupplyConfigurationErrorType Data Type: Integer Possible Data Values Meaning of Data Value vendorMismatch(1) The power supply configuration error type is vendor mismatch. revisionMismatch(2) The power supply configuration error type is revision mismatch. processorMissing(3) The power supply configuration error type is processor missing. Table 9-6. Voltage Probe Type Variable Name: DellVoltageType Data Type: Integer Possible Data Values Meaning of Data Value voltageProbeTypeIsOther(1) The voltage probe type is not one of the following: voltageProbeTypeIsUnknown(2) The voltage probe type is unknown (not known or not monitored). voltageProbeTypeIs1Point5Volt The voltage probe type is a 1.5-volt (V) (3) probe. voltageProbeTypeIs3Point3Volt The voltage probe type is a 3.3-V probe. (4) voltageProbeTypeIs5Volt(5) The voltage probe type is a 5-V probe. voltageProbeTypeIsMinus5Volt The voltage probe type is a –5-V probe. (6) voltageProbeTypeIs12Volt(7) The voltage probe type is a 12-V probe. voltageProbeTypeIsMinus12Volt The voltage probe type is a –12-V probe. (8) voltageProbeTypeIsIO(9) The voltage probe type is an I/O volt probe. Power Group 191 Table 9-6. Voltage Probe Type (continued) Variable Name: DellVoltageType Data Type: Integer Possible Data Values Meaning of Data Value voltageProbeTypeIsCore(10) The voltage probe type is a core volt probe. voltageProbeTypeIsFLEA(11) The voltage probe type is a FLEA (standby) volt probe. voltageProbeTypeIsBattery(12) The voltage probe type is a battery volt probe. voltageProbeTypeIsTerminator The voltage probe type is a SCSI (13) termination volt probe. voltageProbeTypeIs2Point5Volt The voltage probe type is a 2.5-V probe. (14) The voltage probe type is a ground termination logic (GTL) probe. voltageProbeTypeIsGTL(15) voltageProbeTypeIsDiscrete(16) The voltage probe type is a voltage probe with discrete reading. Table 9-7. Voltage Probe Discrete Reading Variable Name: DellVoltageDiscreteReading Data Type: Integer Possible Data Values Meaning of Data Value voltageIsGood(1) The voltage probe discrete reading is good. voltageIsBad(2) The voltage probe discrete reading is bad. 192 Power Group Table 9-8. Amperage Probe Definitions Variable Name: DellAmperageType Data Type: Integer Possible Data Values Meaning of Data Value amperageProbeTypeIsOther(1) The amperage probe type is not one of the following: amperageProbeTypeIsUnknown(2) The amperage probe type is unknown (not known or not monitored). amperageProbeTypeIs1Point5Volt(3) The amperage probe type is a 1.5-ampere (A) probe. amperageProbeTypeIs3Point3volt(4) The amperage probe type is a 3.3-A probe. amperageProbeTypeIs5Volt(5) The amperage probe type is a 5-A probe. amperageProbeTypeIsMinus5Volt(6) The amperage probe type is a –5-A probe. amperageProbeTypeIs12Volt(7) The amperage probe type is a 12-A probe. amperageProbeTypeIsMinus12Volt(8) The amperage probe type is a –12-A probe. amperageProbeTypeIsIO(9) The amperage probe type is an I/O amperage probe. amperageProbeTypeIsCore(10) The amperage probe type is a core amperage probe. amperageProbeTypeIsFLEA(11) The amperage probe type is a FLEA (standby) amperage probe. amperageProbeTypeIsBattery(12) The amperage probe type is a battery amperage probe. amperageProbeTypeIsTerminator(13) The amperage probe type is a Small Computer System Interface (SCSI) termination amperage probe. Power Group 193 Table 9-8. Amperage Probe Definitions (continued) Variable Name: DellAmperageType Data Type: Integer Possible Data Values Meaning of Data Value amperageProbeTypeIs2Point5Volt(14) The amperage probe type is a 2.5-V amperage probe. amperageProbeTypeIsGTL(15) The amperage probe type is a Gunning Transceiver Logic (GTL) probe. amperageProbeTypeIsDiscrete(16) The amperage probe type is an amperage probe with discrete reading. amperageProbeTypeIsPowerSupplyAmps(23) The amperage probe type is power supply probe with reading in Amperes. amperageProbeTypeIsPowerSupplyWatts The amperage probe type is (24) power supply probe with reading in Watts. amperageProbeTypeIsSystemAmps(25) The amperage probe type is system probe with reading in Amperes. amperageProbeTypeIsSystemWatts(26) The amperage probe type is system probe with reading in Watts. Table 9-9. Amperage Probe Discrete Reading Variable Name: DellAmperageDiscreteReading Data Type: Integer Possible Data Values Meaning of Data Value amperageIsGood(1) The amperage probe discrete reading is good. amperageIsBad(2) The amperage probe discrete reading is bad. 194 Power Group Table 9-10. AC Power Switch Capabilities Variable Name: DellACPowerSwitchCapabilities Data Type: Integer Possible Data Values Meaning of Data Value unknownCapabilities(1) The AC power switch’s capabilities are unknown. inputSourceCord1NoReturnCapable(2) Input source is AC power cord 1, with no return. inputSourceCord1ReturnCapable(4) Input source is AC power cord 1, with return. inputSourceCord2NoReturnCapable(8) Input source is AC power cord 2, with no return. inputSourceCord2ReturnCapable(16) Input source is AC power cord 2, with return. inputSourceSharedCapable(32) Input source is shared. Table 9-11. AC Power Switch Settings Variable Name: DellACPowerSwitchSettings Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) The AC power switch’s settings are unknown. inputSourceCord1NoReturn(2) Input source is AC power cord 1, with no return. inputSourceCord1Return(4) Input source is AC power cord 1, with return. inputSourceCord2NoReturn(8) Input source is AC power cord 2, with no return. inputSourceCord2Return(16) Input source is AC power cord 2, with return. inputSourceShared(32) Input source is shared. Power Group 195 Table 9-12. AC Power Switch Redundancy Mode Variable Name: DellACPowerSwitchRedundancyMode Data Type: Integer Possible Data Values Meaning of Data Value nonRedundant(1) The AC power switch is not expecting redundancy. redundant(2) The AC power switch is expecting redundancy. Table 9-13. AC Power Cord State Capabilities Variable Name: DellACPowerCordStateCapabilities Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) The AC power cord’s capabilities are unknown. onlineCapable(2) The AC power cord can be disabled (offline) or enabled (online). notReadyCapable(4) The AC power cord’s capabilities are not ready. Table 9-14. AC Power Cord State Settings Variable Name: DellACPowerCordStateSettings Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) The AC power cord’s state is unknown. online(2) The AC power cord’s state is disabled (offline) 0 or enabled (online) 1. notReady(4) The AC power cord’s state is not ready. acPowerCordHasPower The AC power cord has power. (8) acPowerCordIsActive The AC power cord is the active source of Source(16) AC power. 196 Power Group Table 9-15. Battery Reading Variable Name: DellBatteryReading Data Type: Integer NOTE: These values are bit masks, so combination values are possible. Possible Data Values Meaning of Data Value predictiveFailure(1) Battery sensor detects predictive failure. failed(2) Battery has failed. presenceDetected(4) Battery presence is detected. Table 9-16. Power Cap Capabilities Variable Name: DellPowerCapCapabilities Data Type: Integer NOTE: These values are bit masks, so combination values are possible. Possible Data Values Meaning of Data Value none(0) No power cap capabilities are available. enable(1) Power cap can be enabled. disable(2) Power cap can be disabled. Table 9-17. Power Cap Setting Variable Name: DellPowerCapSetting Data Type: Integer Possible Data Values Meaning of Data Value disabled(0) Power cap is disabled. enabled(1) Power cap is enabled. Power Group 197 Table 9-18. Power Profile Type Variable Name: DellPowerProfileType Data Type: Integer NOTE: These values are bit masks, so combination values are possible. Possible Data Values Meaning of Data Value maxPerformance(1) Power profile type is Maximum Performance. osControl(2) Power profile type is OS control. activePowerController(4) Power profile type is Active Power Controller. custom(8) Power profile type is Custom. Table 9-19. CPU Power Performance Management Type Variable Name: DellCPUPowerPerformanceManagementType Data Type: Integer NOTE: These values are bit masks, so combination values are possible. Possible Data Values Meaning of Data Value maxPerformance(1) CPU power and performance management type is Maximum Performance. minPower(2) CPU power and performance management type is Minimum Power. osDBPM(4) CPU power and performance management type is OS Demand Based Power Management. systemDBPM(8) CPU power and performance management type is System Demand Based Power Management. 198 Power Group Table 9-20. Memory Power Performance Management Type Variable Name: DellMemoryPowerPerformanceManagementType Data Type: Integer NOTE: These values are bit masks, so combination values are possible. Possible Data Values Meaning of Data Value maxPerformance(1) Memory power and performance management type is Maximum Performance. mhz1333(2) Memory power and performance is 1333 MHz. mhz1067(4) Memory power and performance is 1067 MHz. mhz800(8) Memory power and performance is 800 MHz. minPower(16) Memory power and performance management type is Minimum Power. Table 9-21. Fan Power Performance Management Type Variable Name: DellFanPowerPerformanceManagementType Data Type: Integer NOTE: These values are bit masks, so combination values are possible. Possible Data Values Meaning of Data Value maxPerformance(1) Fan power and performance management type is Maximum Performance. minPower(2) Fan power and performance management type is Minimum Power. Power Group 199 200 Power Group 10 Thermal Group The Thermal Group provides information about cooling units, cooling devices, and temperature probes. Cooling units are sets of fans or other cooling devices in a system chassis. Thermal Group variables include threshold values and types of cooling devices and temperature probes. Thermal Group Tables The following management information base (MIB) tables define the objects in the Thermal Group: • "Cooling Unit Table" on page 201 • "Cooling Unit Status" on page 203 • "Temperature Probe Table" on page 209 Cooling Unit Table Name coolingUnitTable Object ID 1.3.6.1.4.1.674.10892.1.700.10 Description Defines the Cooling Unit Table. Syntax TableEntry Access Not accessible Cooling Unit Table Entry Name coolingUnitTableEntry Object ID 1.3.6.1.4.1.674.10892.1.700.10.1 Description Defines the Cooling Unit Table entry. Syntax TableEntry Access Not accessible Index coolingUnitchassisIndex, coolingUnitIndex Thermal Group 201 Cooling Unit Chassis Index Name coolingUnitchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.700.10.1.1 Description Defines the index (one-based) of this chassis. Syntax TableEntry Access Read-only Cooling Unit Index Name coolingUnitIndex Object ID 1.3.6.1.4.1.674.10892.1.700.10.1.2 Description Defines the index (one-based) of cooling units. Syntax DellObjectRange Access Read-only Cooling Unit State Capabilities Name coolingUnitStateCapabilties Object ID 1.3.6.1.4.1.674.10892.1.700.10.1.3 Description Defines the capabilities of the cooling unit. Syntax DellStateCapabilities Access Read-only Cooling Unit State Settings Name coolingUnitStateSettings Object ID 1.3.6.1.4.1.674.10892.1.700.10.1.4 Description Defines the state and settings of the cooling unit. Syntax DellStateSettings Access Read-write 202 Thermal Group Cooling Unit Redundancy Status Name coolingUnitRedundancyStatus Object ID 1.3.6.1.4.1.674.10892.1.700.10.1.5 Description Defines the redundancy status of the cooling unit. Syntax DellStatusRedundancy Access Read-only Cooling Device Count For Redundancy Name coolingDeviceCountForRedundancy Object ID 1.3.6.1.4.1.674.10892.1.700.10.1.6 Description Defines the total number of cooling devices required for this cooling unit to have redundancy. Syntax DellObjectRange Access Read-only Cooling Unit Name Name coolingUnitName Object ID 1.3.6.1.4.1.674.10892.1.700.10.1.7 Description Defines the cooling unit name in this chassis. Syntax DellString Access Read-only Cooling Unit Status Name coolingUnitStatus Object ID 1.3.6.1.4.1.674.10892.1.700.10.1.8 Description Defines the status of the cooling unit in this chassis. Syntax DellStatus Access Read-only Thermal Group 203 Cooling Device Table Name coolingDeviceTable Object ID 1.3.6.1.4.1.674.10892.1.700.12 Description Defines the Cooling Device Table. Syntax CoolingDeviceTableEntry Access Not accessible Cooling Device Table Entry Name coolingDeviceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.700.12.1 Description Defines the Cooling Device Table entry. Syntax CoolingDeviceTableEntry Access Not accessible Index cooling DevicechassisIndex, coolingDeviceIndex Cooling Device Chassis Index Name coolingDevicechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Cooling Device Index Name coolingDeviceIndex Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.2 Description Defines the index of cooling devices in this chassis. Syntax DellObjectRange Access Read-only 204 Thermal Group Cooling Device State Capabilities Name coolingDeviceStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.3 Description Defines the capabilities of the cooling device. Syntax DellStateCapabilities Access Read-only Cooling Device State Settings Name coolingDeviceStateSettings Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.4 Description Defines the state and settings of the cooling device. Syntax DellStateSettings Access Read-write Cooling Device Status Name coolingDeviceStatus Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.5 Description Defines the status of the cooling device. Syntax DellStatusProbe Access Read-only Thermal Group 205 Cooling Device Reading Name coolingDeviceReading Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.6 Description Defines either the cooling device’s speed in revolutions per minute (RPM), or the off/on value of the fan. When the value for coolingDeviceSubType is other than coolingDeviceSubTypeIsDiscrete, the value returned for this attribute is the speed in RPM or the OFF/ON value of the cooling device. When the value for coolingDeviceSubType is coolingDeviceSubTypeIsDiscrete, a value is not returned for this attribute. Syntax DellSigned32BitRange Access Read-only Cooling Device Type Name coolingDeviceType Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.7 Description Defines the cooling device type. Syntax DellCoolingDeviceType (See Table 10-1) Access Read-only Cooling Device Location Name Name coolingDeviceLocationName Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.8 Description Defines the location of the cooling device in this chassis. Syntax DellString Access Read-only 206 Thermal Group Cooling Device Upper Nonrecoverable Threshold Name coolingDeviceUppernonrecoverableThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.9 Description Defines the value of the fan’s upper nonrecoverable threshold. Syntax DellSigned32BitRange Access Read-only Cooling Device Upper Critical Threshold Name coolingDeviceUpperCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.10 Description Defines the value of the fan’s upper critical threshold. Syntax DellSigned32BitRange Access Read-only Cooling Device Upper Noncritical Threshold Name coolingDeviceUpperNonCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.11 Description Defines the user-assigned value of the fan’s upper noncritical threshold. Syntax DellSigned32BitRange Access Read-write Cooling Device Lower Noncritical Threshold Name coolingDeviceLowerNonCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.12 Description Defines the user-assigned value of the fan’s lower noncritical threshold. Syntax DellSigned32BitRange Access Read-write Thermal Group 207 Cooling Device Lower Critical Threshold Name coolingDeviceLowerCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.13 Description Defines the value of the fan’s lower critical threshold. Syntax DellSigned32BitRange Access Read-only Cooling Device Lower Nonrecoverable Threshold Name coolingDeviceLowerNonRecoverableThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.14 Description Defines the value of the fan’s lower nonrecoverable threshold. Syntax DellSigned32BitRange Access Read-only Cooling Device Cooling Unit Index Reference Name coolingDevicecoolingUnitIndexReference Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.15 Description Defines the index for the associated system cooling unit in this chassis. Syntax DellObjectRange Access Read-only Cooling Device Subtype Name coolingDeviceSubType Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.16 Description Defines the cooling device subtype. Syntax DellCoolingDeviceSubType (See Table 10-2) Access Read-only 208 Thermal Group Cooling Device Probe Capabilities Name coolingDeviceProbeCapabilities Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.17 Description Defines the probe capabilities of the cooling device. Syntax DellProbeCapabilities Access Read-only Cooling Device Discrete Reading Name coolingDeviceDiscreteReading Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.18 Description Defines the reading for a voltage probe of type coolingDeviceSubTypeIsDiscrete. When the value for coolingDeviceSubType is other than coolingDeviceSubTypeIsDiscrete, a value is not returned for this attribute. When the value for coolingDeviceSubType is coolingDeviceSubTypeIsDiscrete, the value returned for this attribute is the discrete reading for the cooling device. Syntax DellCoolingDeviceDiscreteReading (See Table 10-3) Access Read-only Temperature Probe Table Name temperatureProbeTable Object ID 1.3.6.1.4.1.674.10892.1.700.20 Description Defines the Temperature Probe Table. Syntax TemperatureProbeTableEntry Access Not accessible Thermal Group 209 Temperature Probe Table Entry Name temperatureProbeTableEntry Object ID 1.3.6.1.4.1.674.10892.1.700.20.1 Description Defines the Temperature Probe Table entry. Syntax TemperatureProbeTableEntry Access Not accessible Index temperatureProbechassisIndex, temperatureProbeIndex Temperature Probe Chassis Index Name temperatureProbechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Temperature Probe Index Name temperatureProbeIndex Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.2 Description Defines the index of temperature probes in this chassis. Syntax DellObjectRange Access Read-only Temperature Probe State Capabilities Name temperatureProbeStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.3 Description Defines the capabilities of the temperature probe. Syntax DellStateCapabilities Access Read-only 210 Thermal Group Temperature Probe State Settings Name temperatureProbeStateSettings Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.4 Description Defines the state and settings of the temperature probe. Syntax DellStateSettings Access Read-write Temperature Probe Status Name temperatureProbeStatus Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.5 Description Defines the status of the temperature probe in tenths of degrees Celsius. Syntax DellStatusProbe Access Read-only Temperature Probe Reading Name temperatureProbeReading Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.6 Description Defines the value of the temperature probe. When the value for temperatureProbeType is other than temperatureProbeTypeIsDiscrete, the value returned for this attribute is the temperature that the probe is reading in tenths of degrees Centigrade. When the value for temperatureProbeType is temperatureProbeTypeIsDiscrete, a value is not returned for this attribute. Syntax DellSigned32BitRange Access Read-only Thermal Group 211 Temperature Probe Type Name temperatureProbeType Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.7 Description Defines the temperature probe type. Syntax DellTemperatureProbeType (See Table 10-4) Access Read-only Temperature Probe Location Name Name temperatureProbeLocationName Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.8 Description Defines the location of the temperature probe in this chassis. Syntax DellString Access Read-only Temperature Probe Upper Nonrecoverable Threshold Name temperatureProbeUpperNonRecoverableThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.9 Description Defines the value of the temperature probe’s upper nonrecoverable threshold. Syntax DellSigned32BitRange Access Read-only Temperature Probe Upper Critical Threshold Name temperatureProbeUpperCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.10 Description Defines the value of the temperature probe’s upper critical threshold. Syntax DellSigned32BitRange Access Read-only 212 Thermal Group Temperature Probe Upper Noncritical Threshold Name temperatureProbeUpperNonCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.11 Description Defines the user-assigned value of the temperature probe’s upper noncritical threshold. Syntax DellSigned32BitRange Access Read-write Temperature Probe Lower Noncritical Threshold Name temperatureProbeLowerNonCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.12 Description Defines the user-assigned value of the temperature probe’s lower noncritical threshold. Syntax DellSigned32BitRange Access Read-write Temperature Probe Lower Critical Threshold Name temperatureProbeLowerCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.13 Description Defines the value of the temperature probe’s lower critical threshold. Syntax DellSigned32BitRange Access Read-only Temperature Probe Lower Nonrecoverable Threshold Name temperatureProbeLowerNonRecoverableThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.14 Description Defines the value of the temperature probe’s lower nonrecoverable threshold. Syntax DellSigned32BitRange Access Read-only Thermal Group 213 Temperature Probe Probe Capabilities Name temperatureProbeProbeCapabilities Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.15 Description Defines the probe capabilities of the temperature probe. Syntax DellProbeCapabilities Access Read-only Temperature Probe Discrete Reading Name temperatureProbeDiscreteReading Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.16 Description Defines the reading for a temperature probe of type temperatureProbeTypeIsDiscrete. When the value for temperatureProbeType is other than temperatureProbeTypeIsDiscrete, a value is not returned for this attribute. When the value for temperatureProbeType is temperatureProbeTypeIsDiscrete, the value returned for this attribute is the discrete reading for the probe. Syntax DellTemperatureDiscreteReading (See Table 10-5) Access Read-only 214 Thermal Group Thermal Group Variable Values This section includes definitions for server administrator-specific variable values used in this section. Table 10-1. Cooling Device Type Variable Name: DellCoolingDeviceType Data Type: Integer Possible Data Values Meaning of Data Value coolingDeviceTypeIsOther(1) The cooling device type is not one of the following: coolingDeviceTypeIsUnknown(2) The cooling device type is unknown (not known or not monitored). coolingDeviceTypeIsAFan(3) The cooling device type is a fan. coolingDeviceTypeIsABlower(4) The cooling device type is a centrifugal blower. coolingDeviceTypeIsAChipFan(5) The cooling device type is a fan on an integrated circuit. coolingDeviceTypeIsACabinetFan(6) The cooling device type is a cabinet fan. coolingDeviceTypeIsAPowerSupplyFan(7) The cooling device type is a power supply fan. coolingDeviceTypeIsAHeatPipe(8) The cooling device type is a heat pipe. coolingDeviceTypeIsRefrigeration(9) The cooling device type is an integrated refrigeration unit. coolingDeviceTypeIsActiveCooling(10) The cooling device type is an active cooling device. coolingDeviceTypeIsPassiveCooling(11) The cooling device type is a passive cooling device. Thermal Group 215 Table 10-2. Cooling Device Subtype Variable Name: DellCoolingDeviceSubType Data Type: Integer Possible Data Values Meaning of Data Value coolingDeviceSubTypeIsOther(1) The cooling device subtype is not one of the following: coolingDeviceSubTypeIsUnknown(2) The cooling device subtype is unknown (not known or not monitored). coolingDeviceSubTypeIsAFanThatReads The cooling device subtype is a InRPM(3) fan that reads in RPMs. coolingDeviceSubTypeIsAFanReadsONor The cooling device subtype is a OFF(4) fan that reads 0 (off) or 1 (on). coolingDeviceSubTypeIsAPowerSupply The cooling device subtype is a FanThatReadsinRPM(5) power supply fan that reads in RPMs. coolingDeviceSubTypeIsAPowerSupply The cooling device subtype is a FanThatReads- ONorOFF(6) power supply fan that reads 0 (off) or 1 (on). coolingDeviceSubTypeIsDiscrete(16) The cooling device subtype is a cooling device with discrete reading. Table 10-3. Cooling Device Discrete Reading Variable Name: DellCoolingDeviceDiscreteReading Data Type: Integer Possible Data Values Meaning of Data Value coolingDeviceIsGood(1) The cooling device discrete reading is good. coolingDeviceIsBad(2) The cooling device discrete reading is bad. 216 Thermal Group Table 10-4. Temperature Probe Type Variable Name: DellTemperatureProbeType Data Type: Integer Possible Data Values Meaning of Data Value temperatureProbeTypeIsOther(1) The temperature probe subtype is not one of the following: temperatureProbeTypeIsUnknown(2) The temperature probe subtype is unknown (not known or not monitored). temperatureProbeTypeIsAmbientESM(3) The temperature probe is for ambient Embedded Systems Management (ESM). temperatureProbeTypeIsDiscrete(16) Table 10-5. The temperature probe subtype is a temperature probe with discrete reading. Temperature Probe Discrete Reading Variable Name: DellTemperatureDiscreteReading Data Type: Integer Possible Data Values Meaning of Data Value temperatureIsGood(1) The temperature probe discrete reading is good. temperatureIsBad(2) The temperature probe discrete reading is bad. Thermal Group 217 218 Thermal Group 11 User Security Group The User Security Table defines the objects that allow administrators to create and modify user accounts and to control which users can perform Set operations on managed systems. User Security Group Table The User Security Group defines objects in the User Security MIB table. User Security Table The following object sets up the User Security Table: Name userSecurityTable Object ID 1.3.6.1.4.1.674.10892.1.800 Description Contains the database of users that are authorized to perform Set operations on a managed system. Syntax UserSecurityTableEntry Access Not accessible User Security Table Entry Name userSecurityTableEntry Object ID 1.3.6.1.4.1.674.10892.1.800.1 Description Defines a row in the User Security Table. Syntax UserSecurityTableEntry Access Not accessible Index userSecuritychassisIndex, userSecurityIndex User Security Group 219 User Security Chassis Index Name userSecuritychassisIndex Object ID 1.3.6.1.4.1.674.10892.1.800.1.1 Description Defines the user security index (one-based) of this chassis. Syntax DellObjectRange Access Read-only User Security Index Name userSecurityIndex Object ID 1.3.6.1.4.1.674.10892.1.800.1.2 Description Defines the user security index. Syntax DellObjectRange Access Read-only User Security User Name Name userSecurityUserName Object ID 1.3.6.1.4.1.674.10892.1.800.1.3 Description Defines the user security user name. Syntax DellSecurityString Access Read-only User Security Control Name Name userSecurityControlName Object ID 1.3.6.1.4.1.674.10892.1.800.1.4 Description Defines a control name used for creating, deleting, and editing users. Syntax DellSecurityString Access Read-write 220 User Security Group User Security Request Name Name userSecurityRequestName Object ID 1.3.6.1.4.1.674.10892.1.800.1.5 Description Defines a request name used for creating, deleting, and editing users. Syntax DellSecurityString Access Read-write User Security Group 221 222 User Security Group Remote Flash BIOS Group 12 The Remote Flash Basic Input/Output System (BIOS) Table defines the variables used to remotely update the BIOS in a system. The variables also define the capabilities of BIOS updates on the system. Remote Flash BIOS Group Table The Remote Flash BIOS Group defines objects in the Remote Flash BIOS MIB table. Remote Flash BIOS Table The following object sets up the Remote Flash BIOS Table: Name remoteFlashBIOSTable Object ID 1.3.6.1.4.1.674.10892.1.900.10 Description Defines the Remote Flash BIOS Table. Syntax RemoteFlashBIOSTableEntry Access Not accessible Remote Flash BIOS Table Entry Name remoteFlashBIOSTableEntry Object ID 1.3.6.1.4.1.674.10892.1.900.10.1 Description Defines the Remote Flash BIOS Table entry. Syntax RemoteFlashBIOSTableEntry Access Not accessible Index remoteFlashBIOSchassisIndex, remoteFlashBIOSIndex Remote Flash BIOS Group 223 Remote Flash BIOS Chassis Index Name remoteFlashBIOSchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.900.10.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Remote Flash BIOS Index Name remoteFlashBIOSIndex Object ID 1.3.6.1.4.1.674.10892.1.900.10.1.2 Description Defines the index to the remote BIOS update hardware on this system. Syntax DellObjectRange Access Read-only Remote Flash BIOS State Capabilities Unique Name remoteFlashBIOSStateCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.900.10.1.3 Description Defines the capabilities of the remote BIOS update hardware on this system. Syntax DellRemoteFlashBIOSStateCapabilitiesUnique (See Table 12-1) Access Read-only Remote Flash BIOS State Settings Unique Name remoteFlashBIOSStateSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.900.10.1.4 Description Defines the state and settings of the remote BIOS update hardware on this system. Syntax DellRemoteFlashBIOSStateSettingsUnique (See Table 12-2) Access Read-write 224 Remote Flash BIOS Group Remote Flash BIOS Status Name remoteFlashBIOSStatus Object ID 1.3.6.1.4.1.674.10892.1.900.10.1.5 Description Defines the status of the remote BIOS update hardware on this system. Syntax DellRemoteFlashBIOSStateStatus Access Read-only Remote Flash BIOS Last BIOS Date Name Name remoteFlashBIOSLastBIOSDateName Object ID 1.3.6.1.4.1.674.10892.1.900.10.1.6 Description Defines the date of the last BIOS update. Syntax DellDateName Access Read-only Remote Flash BIOS Completion Code Name remoteFlashBIOSCompletionCode Object ID 1.3.6.1.4.1.674.10892.1.900.10.1.7 Description Defines the completion code of the last BIOS update. Syntax DellRemoteFlashBIOSCompletionCode (See Table 12-3 on page 227) Access Read-only Remote Flash BIOS Minimum Contiguous Memory Name remoteFlashBIOSMinimumContiguousMemory Object ID 1.3.6.1.4.1.674.10892.1.900.10.1.8 Description Defines the minimum size of contiguous memory required for remote BIOS update in kilobytes. Syntax DellUnsigned32BitRange Access Read-only Remote Flash BIOS Group 225 Remote Flash BIOS Variable Values This section includes definitions for server administrator-specific variable values used in this section. Table 12-1. Remote Flash BIOS State Capabilities Unique Variable Name: DellRemoteFlashBIOSStateCapabilitiesUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) The remote flash BIOS’s capabilities are unknown. enableCapable(2) The remote flash BIOS can be disabled (offline, a binary 0 value) or enabled (online, a binary 1 value). notReadyCapable(4) The remote flash BIOS can be set to indicate not ready. cancelCapable(8) Flash of BIOS can be canceled. enableAndCancelCapable(10) Flash of BIOS can be enabled or canceled. Table 12-2. Remote Flash BIOS State Settings Variable Name: DellRemoteFlashBIOSStateSettingsUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) The remote flash BIOS’s capabilities are unknown. enabled(2) The remote flash BIOS update is disabled (offline, a binary 0 value) or enabled (online, a binary 1 value). notReady(4) The remote flash BIOS’s state is not ready. canceled(8) The remote flash BIOS has been canceled. pending(16) The remote flash BIOS update is pending. other(32) The remote flash BIOS state/setting is not one of the previous values. 226 Remote Flash BIOS Group Table 12-3. Remote Flash BIOS Completion Code Variable Name: DellRemoteFlashBIOSCompletionCode Data Type: Integer Possible Data Values Meaning of Data Value completionCodeIsOther(1) The completion code status is not one of the following: completionCodeIsUnknown(2) The completion code is unknown (not known or not monitored). completionCodeIsOK(3) This completion code completed successfully. completionCodeIsBadImage(4) This completion code is a bad flash BIOS image. completionCodeIsNoFileAccess(5) Flash BIOS could not be accessed. completionCodeIsNotReady(6) Flash BIOS memory not ready. completionCodeIsDisabled(7) Flash BIOS is currently disabled. completionCodeIsNoBattery(8) A battery must be installed. completionCodeIsNoChargedBattery(9) A fully charged battery must be installed. completionCodeIsNoExternalPower(10) An external power adapter must be connected. 12 volts (V) could not be set. completionCodeIsNo12VoltSet(11) completionCodeIsNo12VoltRemoval(12) 12 V could not be removed. completionCodeIsFlashMemoryFailed (13) A flash memory failure occurred. completionCodeIsGeneralFailure(14) A general failure occurred. completionCodeIsDataMiscompare(15) A data miscompare error occurred. completionCodeIsNoImageFound(16) The flash BIOS image could not be found in memory. completionCodeIsNoUpdatePerformed (17) No update operation has been performed. Remote Flash BIOS Group 227 228 Remote Flash BIOS Group 13 Port Group The Port Group provides information about the different types of ports that may be present in your system. This management information base (MIB) group also provides information about the capabilities, states, and settings that are possible for each port. Port Group Tables The following MIB tables define objects in the Port Group: • "Pointing Port Table" on page 229 • "Keyboard Port Table" on page 232 • "Processor Port Table" on page 235 • "Memory Device Port Table" on page 238 • "Monitor Port Table" on page 241 • "Small Computer System Interface (SCSI) Port Table" on page 244 • "Parallel Port Table" on page 246 • "Serial Port Table" on page 250 • "Universal Serial Bus (USB) Port Table" on page 254 Pointing Port Table Name pointingPortTable Object ID 1.3.6.1.4.1.674.10892.1.1000.10 Description Defines the Pointing Port Table. Syntax IntegerPointingPortTableEntry Access Not accessible Port Group 229 Pointing Port Table Entry Name pointingPortTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1000.10.1 Description Defines the Pointing Port Table entry. Syntax PointingPortTableEntry Access Not accessible Index pointingPortchassisIndex, pointingPortIndex Pointing Port Chassis Index Name pointingPortchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.10.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Pointing Port Index Name pointingPortIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.10.1.2 Description Defines the index of the pointing ports in this chassis. Syntax DellObjectRange Access Read-only Pointing Port State Capabilities Name pointingPortStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1000.10.3 Description Defines the capabilities of the pointing port. Syntax DellStateCapabilities Access Read-only 230 Port Group Pointing Port State Settings Name pointingPortStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1000.10.4 Description Defines the state and settings of the pointing port. Syntax DellStateSettings Access Read-write Pointing Port Status Name pointingPortStatus Object ID 1.3.6.1.4.1.674.10892.1.1000.10.5 Description Defines the status of the pointing port. Syntax DellStatus Access Read-only Pointing Port Security State Name pointingPortSecurityState Object ID 1.3.6.1.4.1.674.10892.1.1000.10.6 Description Defines the security settings of the pointing port. Syntax DellPortSecurityState Access Read-only Pointing Port Connector Type Name pointingPortConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.10.7 Description Defines the connector type of the pointing port. Syntax DellPointingPortConnectorType (See Table 13-1) Access Read-only Port Group 231 Pointing Port Name Name pointingPortName Object ID 1.3.6.1.4.1.674.10892.1.1000.10.8 Description Defines the name of the pointing port. Syntax DellString Access Read-only Pointing Port BIOS Connector Type Name pointingPortBIOSConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.10.9 Description Defines the basic input/output system (BIOS) connector type of the pointing port. Syntax DellGenericPortConnectorType Access Read-only Keyboard Port Table Name keyboardPortTable Object ID 1.3.6.1.4.1.674.10892.1.1000.20 Description Defines the Keyboard Port Table. Syntax IntegerKeyboardPortTableEntry Access Not accessible Keyboard Port Table Entry Name keyboardPortTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1000.20.1 Description Defines the Keyboard Port Table entry. Syntax KeyboardPortTableEntry Access Not accessible Index keyboardPortchassisIndex, keyboardPortIndex 232 Port Group Keyboard Port Chassis Index Name keyboardPortchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.20.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Keyboard Port Index Name keyboardPortIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.20.1.2 Description Defines the index of the keyboard ports in this chassis. Syntax DellObjectRange Access Read-only Keyboard Port State Capabilities Name keyboardPortStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1000.20.1.3 Description Defines the capabilities of the keyboard port. Syntax DellStateCapabilities Access Read-only Keyboard Port State Settings Name keyboardPortStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1000.20.1.4 Description Defines the state and settings of the keyboard port. Syntax DellStateSettings Access Read-only Port Group 233 Keyboard Port Status Name keyboardPortStatus Object ID 1.3.6.1.4.1.674.10892.1.1000.20.1.5 Description Defines the status of the keyboard port. Syntax DellStatus Access Read-only Keyboard Port Security State Name keyboardPortSecurityState Object ID 1.3.6.1.4.1.674.10892.1.1000.20.1.6 Description Defines the security settings of the keyboard port. Syntax DellPortSecurityState Access Read-only Keyboard Port Connector Type Name keyboardPortConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.20.1.7 Description Defines the connector type of the keyboard port. Syntax DellKeyboardPortConnectorType (See Table 13-2) Access Read-only Keyboard Port Name Name keyboardPortName Object ID 1.3.6.1.4.1.674.10892.1.1000.20.1.8 Description Defines the name of the keyboard port. Syntax DellString Access Read-only 234 Port Group Keyboard Port BIOS Connector Type Name keyboardPortBIOSConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.20.1.9 Description Defines the BIOS connector type of the keyboard port. Syntax DellGenericPortConnectorType Access Read-only Processor Port Table Name processorPortTable Object ID 1.3.6.1.4.1.674.10892.1.1000.30 Description Defines the Processor Port Table. Syntax IntegerProcessorPortTableEntry Access Not accessible Processor Port Table Entry Name processorPortTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1000.30.1 Description Defines the Processor Port Table entry. Syntax ProcessorPortTableEntry Access Not accessible Index processorPortchassisIndex, processorPortIndex Processor Port Chassis Index Name processorPortchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.30.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Port Group 235 Processor Port Index Name processorPortIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.30.1.2 Description Defines the index of the processor ports in this chassis. Syntax DellObjectRange Access Read-only Processor Port State Capabilities Name processorPortStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1000.30.1.3 Description Defines the capabilities of the processor port. Syntax DellStateCapabilities Access Read-only Processor Port State Settings Name processorPortStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1000.30.1.4 Description Defines the state and settings of the processor port. Syntax DellStateSettings Access Read-write Processor Port Status Name processorPortStatus Object ID 1.3.6.1.4.1.674.10892.1.1000.30.1.5 Description Defines the status of the processor port. Syntax DellStatus Access Read-only 236 Port Group Processor Port Security State Name processorPortSecurityState Object ID 1.3.6.1.4.1.674.10892.1.1000.30.1.6 Description Defines the security settings of the processor port. Syntax DellPortSecurityState Access Read-only Processor Port Connector Type Name processorPortConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.30.1.7 Description Defines the connector type of the processor port. Syntax DellProcessorPortConnectorType (See Table 13-3) Access Read-only Processor Port Name Name processorPortName Object ID 1.3.6.1.4.1.674.10892.1.1000.30.1.8 Description Defines name of the processor port. Syntax DellString Access Read-only Processor Port BIOS Connector Type Name processorPortBIOSConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.30.1.9 Description Defines the BIOS connector type of the processor port. Syntax DellGenericPortConnectorType Access Read-only Port Group 237 Memory Device Port Table Name memoryDevicePortTable Object ID 1.3.6.1.4.1.674.10892.1.1000.40 Description Defines the Memory Device Port Table. Syntax IntegerMemoryDevicePortTableEntry Access Not accessible Memory Device Port Table Entry Name memoryDevicePortTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1 Description Defines the Memory Device Port Table entry. Syntax MemoryDevicePortTableEntry Access Not accessible Index memoryDevicePortchassisIndex, memoryDevicePortIndex Memory Device Port Chassis Index Name memoryDevicePortchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Memory Device Port Index Name memoryDevicePortIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.2 Description Defines the index of the memory device port in this chassis. Syntax DellObjectRange Access Read-only 238 Port Group Memory Device Port State Capabilities Name memoryDevicePortStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.3 Description Defines the capabilities of the memory device port. Syntax DellStateCapabilities Access Read-only Memory Device Port State Settings Name memoryDevicePortStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.4 Description Defines the state and settings of the memory device port. Syntax DellStateSettings Access Read-write Memory Device Port Status Name memoryDevicePortStatus Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.5 Description Defines the status of the memory device port. Syntax DellStatus Access Read-only Memory Device Port Security State Name memoryDevicePortSecurityState Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.6 Description Defines the security settings of the memory device port. Syntax DellPortSecurityState Access Read-only Port Group 239 Memory Device Port Connector Type Name memoryDevicePortConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.7 Description Defines the connector type of the memory device port. Syntax DellMemoryDevicePortConnectorType (See Table 13-4) Access Read-only Memory Device Port Name Name memoryDevicePortName Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.8 Description Defines the name of the memory device port. Syntax DellString Access Read-only Memory Device Port BIOS Connector Type Name memoryDevicePortBIOSConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.9 Description Defines the BIOS connector type of the memory device port. Syntax DellGenericPortConnectorType Access Read-only Memory Device Port Physical Memory Array Index Reference Name memoryDevicePortPhysicalMemoryArrayIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.10 Description Defines the index to the associated physical memory array. Syntax DellUnsigned32BitRange Access Read-only 240 Port Group Memory Device Port Physical Memory Card Index Reference Name memoryDevicePortPhysicalMemoryCardIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.11 Description Defines the index (one-based) of the Physical Memory Card Table entry for the physical memory card with the same chassis index that this memory device port is associated with (if any). Syntax DellUnsigned32BitRange Access Read-only Monitor Port Table Name monitorPortTable Object ID 1.3.6.1.4.1.674.10892.1.1000.50 Description Defines the Monitor Port Table. Syntax IntegerMonitorPortTableEntry Access Not accessible Monitor Port Table Entry Name monitorPortTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1000.50.1 Description Defines the Monitor Port Table entry. Syntax MonitorPortTableEntry Access Not accessible Index monitorPortchassisIndex, monitorPortIndex Monitor Port Chassis Index Name monitorPortchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.50.1.1 Description Defines the index (one-based) of this chassis Syntax DellObjectRange Access Read-only Port Group 241 Monitor Port Index Name monitorPortIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.50.1.2 Description Defines the index of the monitor ports in this chassis. Syntax DellObjectRange Access Read-only Monitor Port State Capabilities Name monitorPortStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1000.50.1.3 Description Defines the capabilities of the monitor port. Syntax DellStateCapabilities Access Read-only Monitor Port State Settings Name monitorPortStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1000.50.1.4 Description Defines the state of the monitor port. Syntax DellStateSettings Access Read-write Monitor Port Status Name monitorPortStatus Object ID 1.3.6.1.4.1.674.10892.1.1000.50.1.5 Description Defines the status of the monitor port. Syntax DellStatus Access Read-only 242 Port Group Monitor Port Security State Name monitorPortSecurityState Object ID 1.3.6.1.4.1.674.10892.1.1000.50.1.6 Description Defines the security settings of the monitor port. Syntax DellPortSecurityState Access Read-only Monitor Port Connector Type Name monitorPortConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.50.1.7 Description Defines the connector type of the monitor port. Syntax DellMonitorPortConnectorTypes (See Table 13-5) Access Read-only Monitor Port Name Name monitorPortName Object ID 1.3.6.1.4.1.674.10892.1.1000.50.1.8 Description Defines the name of the monitor port. Syntax DellString Access Read-only Monitor Port BIOS Connector Type Name monitorPortBIOSConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.50.1.9 Description Defines the name of the BIOS connector type of the monitor port. Syntax DellGenericPortConnectorType Access Read-only Port Group 243 Small Computer System Interface (SCSI) Port Table Name sCSIPortTable Object ID 1.3.6.1.4.1.674.10892.1.1000.60 Description Defines the SCSI Port Table. Syntax IntegerSCSIPortTableEntry Access Not accessible SCSI Port Table Entry Name sCSIPortTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1000.60.1 Description Defines the SCSI Port Table entry. Syntax SCSIPortTableEntry Access Not accessible Index sCSIPortchassisIndex, sCSIPortIndex SCSI Port Chassis Index Name sCSIPortchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.60.1.1 Description Defines the index (one-based) of this chassis Syntax DellObjectRange Access Read-only SCSI Port Index Name sCSIPortIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.60.1.2 Description Defines the index of the SCSI ports in this chassis. Syntax DellObjectRange Access Read-only 244 Port Group SCSI Port State Capabilities Name sCSIPortStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1000.60.1.3 Description Defines the capabilities of the SCSI port. Syntax DellStateCapabilities Access Read-only SCSI Port State Settings Name DellStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1000.60.1.4 Description Defines the state and settings of the SCSI port. Syntax DellStatus Access Read-write SCSI Port Status Name sCSIPortStatus Object ID 1.3.6.1.4.1.674.10892.1.1000.60.1.5 Description Defines the status of the SCSI port. Syntax DellStatus Access Read-only SCSI Port Security State Name sCSIPortSecurityState Object ID 1.3.6.1.4.1.674.10892.1.1000.60.1.6 Description Defines the security settings of the SCSI port. Syntax DellPortSecurityState Access Read-only Port Group 245 SCSI Port Connector Type Name sCSIPortConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.60.1.7 Description Defines the connector type of the SCSI port. Syntax DellSCSIPortConnectorType (See Table 13-6) Access Read-only SCSI Port Name Name sCSIPortName Object ID 1.3.6.1.4.1.674.10892.1.1000.60.1.8 Description Defines the name of the SCSI port. Syntax DellString Access Read-only SCSI Port BIOS Connector Type Name sCSIPortBIOSConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.60.1.9 Description Defines the BIOS connector type of the SCSI port. Syntax DellGenericPortConnectorType Access Read-only Parallel Port Table Name parallelPortTable Object ID 1.3.6.1.4.1.674.10892.1.1000.70 Description Defines the Parallel Port Table. Syntax IntegerParallelPortTableEntry Access Not accessible 246 Port Group Parallel Port Table Entry Name parallelPortTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1 Description Defines the Parallel Port Table entry. Syntax ParallelPortTableEntry Access Not accessible Index parallelPortchassisIndex, parallelPortIndex Parallel Port Chassis Index Name parallelPortchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Parallel Port Index Name parallelPortIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.2 Description Defines the index of the parallel ports in this chassis. Syntax DellObjectRange Access Read-only Parallel Port State Capabilities Name parallelPortStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.3 Description Defines the capabilities of the parallel port. Syntax DellStateSettings Access Read-write Port Group 247 Parallel Port State Settings Name parallelPortStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.4 Description Defines the state and settings of the parallel port. Syntax DellStateSettings Access Read-write Parallel Port Status Name parallelPortStatus Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.5 Description Defines the status of the parallel port. Syntax DellStatus Access Read-only Parallel Port Security State Name DellPortSecurityState Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.6 Description Defines the security state of the parallel port. Syntax DellStatus Access Read-only Parallel Port Connector Type Name parallelPortConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.7 Description Defines the connector type of the parallel port. Syntax DellParallelPortConnectorType Access Read-only 248 Port Group Parallel Port Name Name parallelPortName Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.8 Description Defines the name of the parallel port. Syntax DellString Access Read-only Parallel Port Connector Pin Out Name parallelPortConnectorPinOut Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.9 Description Defines the pinout of the parallel port. Syntax DellParallelPortConnectorPinout Access Read-only Parallel Port Capabilities Unique Name parallelPortCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.10 Description Defines the capabilities of the parallel port. Syntax DellParallelPortConnectorPinout Access Read-only Parallel Port Base I/O Address Name parallelPortBaseIOAddress Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.11 Description Defines the Base Input/Output (I/O) address of the parallel port. Syntax DellUnsigned64BitRange Access Read-only Port Group 249 Parallel Port IRQ Level Name parallelPortIRQLevel Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.12 Description Defines the Interrupt Request Level (IRQ) of the parallel port. Syntax DellUnsigned8BitRange Access Read-only Parallel Port DMA Support Name parallelPortDMASupport Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.13 Description Defines if direct memory access (DMA) is supported by the parallel port. Syntax DellBoolean Access Read-only Serial Port Table Name serialPortTable Object ID 1.3.6.1.4.1.674.10892.1.1000.80 Description Defines the Serial Port Table. Syntax IntegerSerialPortTableEntry Access Not accessible Serial Port Table Entry Name serialPortTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1 Description Defines the Serial Port Table entry. Syntax SerialPortTableEntry Access Not accessible Index serialPortchassisIndex, serialPortIndex 250 Port Group Serial Port Chassis Index Name serialPortchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Serial Port Index Name serialPortIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.2 Description Defines the index of the serial ports in this chassis. Syntax DellObjectRange Access Read-only Serial Port State Capabilities Name serialPortStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.3 Description Defines the capabilities of the serial port. Syntax DellStateCapabilities Access Read-only Serial Port State Settings Name serialPortStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.4 Description Defines the state and settings of the serial port. Syntax DellStateSettings Access Read-write Port Group 251 Serial Port Status Name serialPortStatus Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.5 Description Defines the status of the serial port. Syntax DellStatus Access Read-only Serial Port Security State Name serialPortSecurityState Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.6 Description Defines the security settings of the serial port. Syntax DellPortSecurityState Access Read-only Serial Port Connector Type Name serialPortConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.7 Description Defines connector type of the serial port. Syntax DellSerialPortConnectorType Access Read-only Serial Port Name Name serialPortName Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.8 Description Defines the name of the serial port. Syntax DellString Access Read-only 252 Port Group Serial Port Maximum Speed Name serialPortMaximumSpeed Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.9 Description Defines the maximum speed the serial interface can support in bits per second (bps). Syntax DellUnsigned32BitRange Access Read-only Serial Port Capabilities Unique Name serialPortCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.10 Description Defines additional capabilities of the serial port. Syntax DellSerialPortCapabilitiesUnique Access Read-only Serial Port Base I/O Address Name serialPortBaseIOAddress Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.11 Description Defines the base I/O address of the serial port. Syntax DellUnsigned64BitRange Access Read-only Serial Port IRQ Level Name serialPortIRQLevel Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.12 Description Defines the IRQ of the serial port. Syntax DellUnsigned8BitRange Access Read-only Port Group 253 Universal Serial Bus (USB) Port Table Name uSBPortTable Object ID 1.3.6.1.4.1.674.10892.1.1000.90 Description Defines the USB Port Table. Syntax IntegerUSBPortTableEntry Access Not accessible USB Port Table Entry Name uSBPortTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1 Description Defines the USB Port Table entry. Syntax USBPortTableEntry Access Not accessible Index uSBPortchassisIndex, uSBPortIndex USB Port Chassis Index Name uSBPortchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only USB Port Index Name uSBPortIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1.2 Description Defines the index of the USB ports in this chassis Syntax DellObjectRange Access Read-only 254 Port Group USB Port State Capabilities Name uSBPortStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1.3 Description Defines the capabilities of the USB port. Syntax DellStateCapabilities Access Read-only USB Port State Settings Name uSBPortStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1.4 Description Defines the state and settings of the USB port. Syntax DellStateSettings Access Read-write USB Port Status Name uSBPortStatus Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1.5 Description Defines the state of the USB port. Syntax DellStatus Access Read-only USB Port Security State Name uSBPortSecurityState Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1.6 Description Defines the security settings of the USB port. Syntax DellPortSecurityState Access Read-only Port Group 255 USB Port Connector Type Name uSBPortConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1.7 Description Defines the connector type of the USB port. Syntax DellUSBPortConnectorType Access Read-only USB Port Name Name uSBPortName Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1.8 Description Defines the name of the USB port. Syntax DellString Access Read-only USB Port BIOS Connector Type Name uSBPortBIOSConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1.9 Description Defines the BIOS connector type of the USB port. Syntax DellGenericPortConnectorType Access Read-only 256 Port Group Port Group Variable Values This section includes definitions for server administrator-specific variable values used in this section. Table 13-1. Pointing Port Connector Type Variable Name: DellPointingPortConnectorType Data Type: Integer Possible Data Values Meaning of Data Value connectorPortTypeIsOther(1) The pointing port connector type is not one of the following: connectorPortTypeIsUnknown(2) The pointing port connector type is unknown. connectorPortTypeIsSerial(3) The pointing port connector type is serial. connectorPortTypeIsPS2(4) The pointing port connector type is a Personal System/2 (PS/2). connectorPortTypeIsInfrared(5) The pointing port connector type is infrared. connectorPortTypeIsHPHIL(6) The pointing port connector type is HP-HIL. connectorPortTypeIsBusMouse(7) The pointing port connector type is a bus mouse. connectorPortTypeIsADB(8) The pointing port connector type is ADB. connectorPortTypeIsDB9(9) The pointing port connector type is nine-pin DB-9. connectorPortTypeIsMicroDIN(10) The pointing port connector type is micro Deutsche Industrie Norm (DIN). connectorPortTypeIsAccessBusUSB (11) The pointing port connector type is Access Bus USB. connectorPortTypeIsPC98(12) The port connector type is a PC-98. Port Group 257 Table 13-2. Keyboard Port Connector Types Variable Name: DellKeyboardPortConnectorType Data Type: Integer Possible Data Values Meaning of Data Value connectorPortTypeIsOther(1) The keyboard port connector type is not one of the following: connectorPortTypeIsUnknown(2) The keyboard port connector type is unknown. connectorPortTypeIsMiniDIN(3) The keyboard port connector type is a mini DIN. connectorPortTypeIsMicroDIN(4) The keyboard port connector type is a MicroDIN. connectorPortTypeIsPS2(5) The keyboard port connector type is PS/2. connectorPortTypeIsInfrared(6) The keyboard port connector type is infrared. connectorPortTypeIsHPHIL(7) The keyboard port connector type is HP-HIL. connectorPortTypeIsDB9(8) The keyboard port connector type is DB-9. connectorPortTypeIsAccessBusUSB(9) The keyboard port connector type is bus USB. connectorPortTypeIsPC98(10) 258 Port Group The keyboard port connector type is PC-98. Table 13-3. Processor Port Connector Types Variable Name: DellProcessorPortConnectorType Data Type: Integer Possible Data Values Meaning of Data Value connectorPortTypeIsOther(1) The processor port connector type is not one of the following: connectorPortTypeIsUnknown(2) The processor port connector type is unknown. connectorPortTypeIsDaughterdBoard(3) The processor port connector type is a daughter board. connectorPortTypeIsZIFSocket(4) The processor port connector type is a zero insertion force (ZIF) socket. connectorPortTypeIsAPiggyBackBoard(5) The processor port connector type is a replacement piggyback board. connectorPortTypeIsNone(6) There is no processor port connector; processor is soldered in place. connectorPortTypeIsLIFSocket(7) The processor port connector type is a low insertion force (LIF) socket. connectorPortTypeIsSlot1(8) The processor port connector type is a slot one. connectorPortTypeIsSlot2(9) The processor port connector type is a slot two. connectorPortTypeIs370PinSocket(10) The processor port connector type is a 370 pin socket. Port Group 259 Table 13-4. Memory Device Port Connector Types Variable Name: DellMemoryDevicePortConnectorType Data Type: Integer Possible Data Value Meaning of Data Value connectorPortTypeIsOther(1) The memory device port connector type is not one of the following: connectorPortTypeIsUnknown(2) The memory device port connector type is unknown. connectorPortTypeIsSIMM(3) The memory device port connector type is a single in-line memory module (SIMM). connectorPortTypeIsSIP(4) The memory device port connector type is a SIP. connectorPortTypeIsAChip(5) The memory device port connector type is a chip. connectorPortTypeIsDIP(6) The memory device port connector type is a dual in-line package (DIP). connectorPortTypeIsZIP(7) The memory device port connector type is a ZIP. connectorPortTypeIsAProprietaryCard(8) The memory device port connector type is a proprietary card. connectorPortTypeIsDIMM(9) The memory device port connector type is a dual in-line memory module (DIMM). connectorPortTypeIsTSOP(10) The memory device port connector type is a TSOP. connectorPortTypeIsARowOfChips(11) The memory device port connector type is a row of chips. 260 Port Group Table 13-4. Memory Device Port Connector Types (continued) Variable Name: DellMemoryDevicePortConnectorType Data Type: Integer Possible Data Value Meaning of Data Value connectorPortTypeIsRIMM(12) The memory device port connector type is a Rambus Inline Memory Module (RIMM). connectorPortTypeIsSODIMM(13) The memory device port connector type is a small outline, dual in-line memory module (SODIMM). connectorPortTypeIsSRIMM(14) The memory device port connector type is a SRIMM. Table 13-5. Monitor Port Connector Types Variable Name: DellMonitorPortConnectorType Data Type: Integer Possible Data Values Meaning of Data Value connectorPortTypeIsOther(1) The monitor port connector type is not one of the following: connectorPortTypeIsUnknown(2) The monitor port connector type is unknown. connectorPortTypeIsDB15PinMale(3) The monitor port connector type is a male DB-15. connectorPortTypeIsDB15PinFemale(4) The monitor port connector type is a female DB-15. Port Group 261 Table 13-6. SCSI Port Connector Types Variable Name: DellSCSIPortConnectorType Data Type: Integer Possible Data Values Meaning of Data Value connectorPortTypeIsOther(1) The SCSI port connector type is not one of the following: connectorPortTypeIsUnknown(2) The SCSI port connector type is unknown. connectorPortTypeIsDIN25pin(3) The SCSI port connector type is a DIN 25-pin. connectorPortTypeIsDIN50pin(4) The SCSI port connector type is a DIN 50-pin. connectorPortTypeIsDIN68pin(5) The SCSI port connector type is a DIN 68-pin. 262 Port Group 14 14 Device Group The Device Group provides information about different types of pointing, keyboard, processor, cache, memory, and peripheral component interconnect (PCI) devices. Variables in this group cover information about type, settings, configuration, manufacturer, address or location, and if applicable, the speed of the device. Device Tables The following management information base (MIB) tables define objects in the Device Group: • "Pointing Device Table" on page 264 • "Keyboard Device Table" on page 266 • "Processor Device Table" on page 269 • "Processor Device Status Table" on page 277 • "Cache Device Table" on page 279 • "Memory Device Table" on page 285 • "Memory Device Mapped Address Table" on page 293 • "Generic Device Table" on page 296 • "PCI Device Table" on page 299 • "PCI Device Configuration Space Table" on page 302 • "Network Device Table" on page 305 • "Managed System Services Device Table" on page 313 • "SD Card Unit Table" on page 315 • "SD Card Device Table" on page 318 Device Group 263 Pointing Device Table Name pointingDeviceTable Object ID 1.3.6.1.4.1.674.10892.1.1100.10 Description Defines the Pointing Device Table. This group of objects references the Pointing Port Index (See Section 12). Syntax SEQUENCE OF PointingDeviceTableEntry Access Not accessible Pointing Device Table Entry Name pointingDeviceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.10.1 Description Defines the Pointing Device Table entry. Syntax PointingDeviceTableEntry Access Not accessible Index pointingDevicechassisIndex, pointingDeviceIndex Pointing Device Chassis Index Name pointingDevicechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.10.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Pointing Device Index Name pointingDeviceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.10.1.2 Description Defines the index of the pointing device in this chassis. Syntax DellObjectRange Access Read-only 264 Device Group Pointing Device State Capabilities Name pointingDeviceStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1100.10.1.3 Description Defines the capabilities of the pointing device. Syntax DellStateCapabilities Access Read-only Pointing Device State Settings Name pointingDeviceStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1100.10.1.4 Description Defines the state of the pointing device. Syntax DellStateSettings Access Read-write Pointing Device Status Name pointingDeviceStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.10.1.5 Description Defines the status of the pointing device. Syntax DellStatus Access Read-only Pointing Port Index Reference Name pointingPortIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.10.1.6 Description Defines the index to the pointing port in this chassis. Syntax DellObjectRange Access Read-only Device Group 265 Pointing Device Type Name pointingDeviceType Object ID 1.3.6.1.4.1.674.10892.1.1100.10.1.7 Description Defines the type of the pointing device. Syntax DellPointingDeviceType (See Table 14-1) Access Read-only Pointing Device Number of Buttons Name pointingDeviceNumberofButtons Object ID 1.3.6.1.4.1.674.10892.1.1100.10.1.8 Description Defines the number of buttons on the pointing device. Syntax DellUnsigned8BitRange Access Read-only Keyboard Device Table Name keyboardDeviceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.20 Description Defines the Keyboard Device Table. This table references the Keyboard Port Index (See Section 12). Syntax SEQUENCE OF KeyboardDeviceTableEntry Access Not accessible Keyboard Device Table Entry Name keyboardDeviceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.20.1 Description Defines the Keyboard Device Table entry. Syntax KeyboardDeviceTableEntry Access Not accessible Index keyboardDevicechassisIndex, keyboardDeviceIndex 266 Device Group Keyboard Device Chassis Index Name keyboardDevicechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.20.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Keyboard Device Index Name keyboardDeviceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.20.1.2 Description Defines the index of the keyboard device for this chassis. Syntax DellObjectRange Access Read-only Keyboard Device State Capabilities Name keyboardDeviceStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1100.20.1.3 Description Defines the capabilities of the keyboard device. Syntax DellStateCapabilities Access Read-only Keyboard Device State Settings Name keyboardDeviceStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1100.20.1.4 Description Defines the state of the keyboard device. Syntax DellStatesSettings Access Read-write Device Group 267 Keyboard Device Status Name keyboardDeviceStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.20.1.5 Description Defines the status of the keyboard device. Syntax DellStatus Access Read-only Keyboard Port Index Reference Name keyboardPortIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.20.1.6 Description Defines the index to the associated the keyboard port in this chassis. Syntax DellStatus Access Read-only Keyboard Device Type Name Name keyboardDeviceTypeName Object ID 1.3.6.1.4.1.674.10892.1.1100.20.1.7 Description Defines the name of the keyboard type. Syntax DellString Access Read-only Keyboard Device Layout Name Name keyboardDeviceLayoutName Object ID 1.3.6.1.4.1.674.10892.1.1100.20.1.8 Description Defines the name of the keyboard layout. Syntax DellString Access Read-only 268 Device Group Processor Device Table Name processorDeviceTable Object ID 1.3.6.1.4.1.674.10892.1.1100.30 Description Defines the Processor Device Table. Syntax SEQUENCE OF ProcessorDeviceTableEntry Access Not accessible Processor Device Table Entry Name processorDeviceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1 Description Defines the Processor Device Table entry. Syntax ProcessorDeviceTableEntry Access Not accessible Index processorDevicechassisIndex, processorDeviceIndex Processor Device Chassis Index Name processorDevicechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Processor Device Index Name processorDeviceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.2 Description Defines the index of the processor device in this chassis. Syntax DellObjectRange Access Read-only Device Group 269 Processor Device State Capabilities Name processorDeviceStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.3 Description Defines the capabilities of the processor device. Syntax DellStateCapabilities Access Read-only Processor Device State Settings Name processorDeviceStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.4 Description Defines the state of the processor device. Syntax DellStateSettings Access Read-write Processor Device Status Name processorDeviceStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.5 Description Defines the status of the processor device. Syntax DellStatus Access Read-only Processor Port Index Reference Name processorPortIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.6 Description Defines the index to the associated processor port in this chassis. Syntax DellObjectRange Access Read-only 270 Device Group Processor Device Type Name processorDeviceType Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.7 Description Defines the type of processor device. Syntax DellProcessorDeviceType (See Table 14-4) Access Read-only Processor Device Manufacturer Name Name processorDeviceManufacturerName Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.8 Description Defines the name of manufacturer of the processor device. Syntax DellString Access Read-only Processor Device Status State Name processorDeviceStatusState Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.9 Description Defines the status state of the processor device. Syntax DellProcessorDeviceStatusState (See Table 14-2) Access Read-only Processor Device Family Name processorDeviceFamily Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.10 Description Defines the family of the processor device. Syntax DellProcessorDeviceFamily (See Table ) Access Read-only Device Group 271 Processor Device Maximum Speed Name processorDeviceMaximumSpeed Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.11 Description Defines the maximum speed of the processor device in megahertz (MHz). A zero (0) indicates that the speed is unknown. Syntax DellUnsigned32BitRange Access Read-only Processor Device Current Speed Name processorDeviceCurrentSpeed Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.12 Description Defines the current speed of the processor device in MHz. A zero (0) indicates that the speed is unknown. Syntax DellUnsigned32BitRange Access Read-only Processor Device External Clock Speed Name processorDeviceExternalClockSpeed Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.13 Description Defines the speed of the external clock (the front-side bus speed) for the processor device in MHz. A zero (0) indicates that the speed is unknown. Syntax DellUnsigned32BitRange Access Read-only 272 Device Group Processor Device Voltage Name processorDeviceVoltage Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.14 Description Defines the voltage powering the processor device in millivolts. A zero (0) indicates the speed is unknown. Syntax DellSigned32BitRange Access Read-only Processor Device Upgrade Information Name processorDeviceUpgradeInformation Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.15 Description Defines the processor upgrade information for the processor device. Syntax DellProcessorUpgradeInformation (See Table 14-5) Access Read-only Processor Device Version Name Name processorDeviceVersionName Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.16 Description Defines the version name of the processor device. Syntax DellString Access Read-only Device Group 273 Processor Device Core Count Name processorDeviceCoreCount Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.17 Description Defines the number of processor cores detected for the processor device. Syntax DellUnsigned32BitRange Access Read-only Processor Device Core Enabled Count Name processorDeviceCoreEnabledCount Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.18 Description Defines the number of processor cores enabled for the processor device. Syntax DellUnsigned32BitRange Access Read-only Processor Device Thread Count Name processorDeviceThreadCount Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.19 Description Defines the number of processor threads detected for the processor device. Syntax DellUnsigned32BitRange Access Read-only 274 Device Group Processor Device Characteristics Name processorDeviceCharacteristics Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.20 Description This attribute defines characteristics of the processor device. This attribute is a bit field where a bit has the meaning defined below when set to 1 (one). NOTE: Bits 2-15 need to be examined in the context of bit 1. If bit 1 is set, the processor characteristics are unknown and bits 2-15 cannot be used to determine if the functions associated with the bits are supported. Bit Position -------------Bit 0 Bit 1 Bit 2 Bit 3-15 Meaning if Set -----------------Reserved Unknown 64-bit capable Reserved Syntax DellUnsigned16BitRange Access Read-only Processor Device Extended Capabilities Name processorDeviceExtendedCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.21 Description This attribute defines extended capabilities of the processor device. This attribute is a bit field where a bit has the meaning defined below when set to 1 (one). Bit Position ---------------Bit 0 Bit 1 Bit 2 Bit 3 Meaning if Set ------------------Virtualization Technology (VT) supported Demand-Based Switching (DBS) supported eXecute Disable (XD) supported Hyper-Threading (HT) supported Syntax DellUnsigned16BitRange Access Read-only Device Group 275 Processor Device Extended Settings Name processorDeviceExtendedSettings Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.22 Description This attribute defines extended settings of the processor device. This attribute is a bit field where a bit has the meaning defined below when set to 1 (one). Bit Position --------------Bit 0 Bit 1 Bit 2 Bit 3 Meaning if Set ------------Virtualization Technology (VT) enabled Demand Based Switching (DBS) enabled eXecute Disable (XD) enabled Hyper-Threading (HT) enabled Syntax DellUnsigned16BitRange Access Read-only Processor Device Brand Name Name processorDeviceBrandName Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.23 Description Defines the brand of the processor device. Syntax DellString Access Read-only Processor Device Model Name Name processorDeviceModelName Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.24 Description Defines the model of the processor device. Syntax DellString Access Read-only 276 Device Group Processor Device Stepping Name Name processorDeviceSteppingName Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.25 Description Defines the stepping of the processor device. Syntax DellString Access Read-only Processor Device Status Table Name processorDeviceStatusTable Object ID 1.3.6.1.4.1.674.10892.1.1100.32 Description Defines the Processor Device Status Table. Syntax SEQUENCE OF ProcessorDeviceStatusTableEntry Access Not accessible Processor Device Status Table Entry Name processorDeviceStatusTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.32.1 Description Defines the Processor Device Status Table Entry. Syntax ProcessorDeviceStatusTableEntry Access Not accessible Index processorDeviceStatusChassisIndex, processorDeviceStatusIndex Processor Device Status Chassis Index Name processorDeviceStatusChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.32.1.1 Description Defines the index (one-based) of the associated chassis. Syntax DellObjectRange Access Read-only Device Group 277 Processor Device Status Index Name processorDeviceStatusIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.32.1.2 Description Defines the index (one-based) of the processor device status probe. Syntax DellObjectRange Access Read-only Processor Device Status State Capabilities Name processorDeviceStatusStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1100.32.1.3 Description Defines the state capabilities of the processor device status probe. Syntax DellStateCapabilities Access Read-only Processor Device Status State Settings Name processorDeviceStatusStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1100.32.1.4 Description Defines the state settings of the processor device status probe. Syntax DellStateSettings Access Read-write Processor Device Status Status Name processorDeviceStatusStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.32.1.5 Description Defines the status of the processor device status probe. This status is joined into the processorDeviceStatus attribute. Syntax DellStatus Access Read-only 278 Device Group Processor Device Status Reading Name processorDeviceStatusReading Object ID 1.3.6.1.4.1.674.10892.1.1100.32.1.6 Description Defines the reading of the processor device status probe. Syntax DellProcessorDeviceStatusReading Access Read-only Processor Device Status Location Name Name processorDeviceStatusLocationName Object ID 1.3.6.1.4.1.674.10892.1.1100.32.1.7 Description Defines the location name of the processor device status probe. Syntax DellString Access Read-only Processor Device Status Port Index Reference Name processorDeviceStatusPortIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.32.1.8 Description Defines the index (one-based) of the associated processor port in the same chassis. Syntax DellObjectRange Access Read-only Cache Device Table Name cacheDeviceTable Object ID 1.3.6.1.4.1.674.10892.1.1100.40 Description Defines the Cache Device Table. Syntax SEQUENCE OF CacheDeviceTableEntry Access Not accessible Device Group 279 Cache Device Table Entry Name cacheDeviceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1 Description Defines the Cache Device Table entry. Syntax CacheDeviceTableEntry Access Not accessible Index cacheDevicechassisIndex, cacheDeviceIndex Cache Device Chassis Index Name cacheDevicechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Cache Device Index Name cacheDeviceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.2 Description Defines the index of the cache device in this chassis. Syntax DellObjectRange Access Read-only Cache Device State Capabilities Name cacheDeviceStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.3 Description Defines the capabilities of the cache device. Syntax DellStateCapabilities Access Read-only 280 Device Group Cache Device State Settings Name cacheDeviceStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.4 Description Defines the state of the cache device. Syntax DellStateSettings Access Read-write Cache Device Status Name cacheDeviceStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.5 Description Defines the status of the cache device. Syntax DellStatus Access Read-only Cache Device Processor Device Index Reference Name cacheDeviceprocessorDeviceIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.6 Description Defines the index number of the processor device with which this cache device is associated. Syntax DellObjectRange Access Read-only Cache Device Type Name cacheDeviceType Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.7 Description Defines the type of cache device. Syntax DellCacheDeviceType (See Table 14-7) Access Read-only Device Group 281 Cache Device Location Name cacheDeviceLocation Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.8 Description Defines the location of the cache device. Syntax DellCacheDeviceLocation (See Table 14-13) Access Read-only Cache Device Status State Name cacheDeviceStatusState Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.9 Description Defines the status state of the cache device. Syntax DellCacheDeviceStatusState (See Table 14-10) Access Read-only Cache Device External Socket Name Name cacheDeviceExternalSocketName Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.10 Description Defines the external socket name of the cache device, if the cache is socketed. Syntax DellString Access Read-only Cache Device Level Name cacheDeviceLevel Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.11 Description Defines the level of the cache device. Syntax DellCacheDeviceLevel (See Table 14-8) Access Read-only 282 Device Group Cache Device Maximum Size Name cacheDeviceMaximumSize Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.12 Description Defines the maximum size of the cache device in kilobytes (KB). A zero (0) indicates that the size is unknown. Syntax DellUnsigned32BitRange Access Read-only Cache Device Current Size Name cacheDeviceCurrentSize Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.13 Description Defines the current size of the cache device in KB. A zero (0) indicates that the size is unknown. Syntax DellUnsigned32BitRange Access Read-only Cache Device Speed Name cacheDeviceSpeed Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.14 Description Defines the speed of the cache device in nanoseconds. A zero (0) indicates that the speed is unknown. Syntax DellUnsigned32BitRange Access Read-only Cache Device Write Policy Name cacheDeviceWritePolicy Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.15 Description Defines the write policy of the cache device. Syntax DellCacheDeviceWritePolicy (See Table 14-9) Access Read-only Device Group 283 Cache Device Is Socketed Name cacheDeviceIsSocketed Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.16 Description Defines if the cache device is socketed. Syntax DellBoolean Access Read-only Cache Device Error Checking and Correction (ECC) Type Name cacheDeviceECCType Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.17 Description Defines the type of error correction in use by the cache device. Syntax DellCacheDeviceECCType (See Table 14-11) Access Read-only Cache Device Associativity Name cacheDeviceAssociativity Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.18 Description Defines the type of associativity in use by the cache device. Syntax DellCacheDeviceAssociativity (See Table 14-12) Access Read-only Cache Device Supported Type Name cacheDeviceSupportedType Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.19 Description Defines the type of static random-access memory (SRAM) that the cache device can support. Syntax DellCacheDeviceSupportedType Access Read-only 284 Device Group Cache Device Current Type Name cacheDeviceCurrentType Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.20 Description Defines the current type of SRAM for the cache device. Syntax DellCacheDeviceSRAMType (See Table 14-14) Access Read-only Memory Device Table Name memoryDeviceTable Object ID 1.3.6.1.4.1.674.10892.1.1100.50 Description Defines the Memory Device Table. Syntax SEQUENCE OF MemoryDeviceTableEntry Access Not accessible Memory Device Table Entry Name memoryDeviceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1 Description Defines the Memory Device Table entry. Syntax MemoryDeviceTableEntry Access Not accessible Index memoryDevicechassisIndex, memoryDeviceIndex Memory Device Chassis Index Name memoryDevicechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Device Group 285 Memory Device Index Name memoryDeviceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.2 Description Defines the index of the memory device in this chassis. Syntax DellObjectRange Access Read-only Memory Device State Capabilities Name memoryDeviceStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.3 Description Defines the capabilities of the memory device. Syntax DellStateCapabilities Access Read-only Memory Device State Settings Name memoryDeviceStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.4 Description Defines the state of the memory device. Syntax DellStateSettings Access Read-write Memory Device Status Name memoryDeviceStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.5 Description Defines the status of the memory device. Syntax DellStatus Access Read-only 286 Device Group Memory Device Memory Port Index Reference Name memoryDeviceMemoryPortIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.6 Description Defines the index of the memory port of which this memory device is part. Syntax DellObjectRange Access Read-only Memory Device Type Name memoryDeviceType Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.7 Description Defines the type of the memory device. Syntax DellMemoryDeviceType (See Table 14-16) Access Read-only Memory Device Location Name Name memoryDeviceLocationName Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.8 Description Defines the location name of the memory device. Syntax DellString Access Read-write Device Group 287 Memory Device Error Count NOTE: "Memory Device Failure Modes" on page 291 has now replaced this attribute. Memory Device Error Count should no longer be used. If you use the Memory Device Error Count attribute, the value returned is always zero, and using the attribute has no effect. Name memoryDeviceErrorCount Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.9 Description Defines the total number of Error Checking and Correction (ECC) errors detected by the memory device. Writing a 0 (zero) to this variable resets the devices error counts. Syntax DellSigned32BitRange Access Read-write Memory Device Bank Location Name Name memoryDeviceBankLocationName Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.10 Description Defines the bank location name of the memory device. Syntax DellString Access Read-only Memory Device Type Details Name memoryDeviceTypeDetails Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.11 Description Defines the detailed type of the memory device. Syntax DellMemoryDeviceTypeDetails (See Table 13-17) Access Read-only 288 Device Group Memory Device Form Factor Name memoryDeviceFormFactor Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.12 Description Defines the form factor of the memory device. Syntax DellMemoryDeviceFormFactor (See Table 14-15) Access Read-only Memory Device Set Name memoryDeviceSet Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.13 Description Defines if the memory device is a part of a set. A zero (0) indicates that this device is not part of a set. Syntax DellUnsigned32BitRange Access Read-only Memory Device Size Name memoryDeviceSize Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.14 Description Defines the size in KB of the memory device. Syntax DellUnsigned32BitRange Access Read-only Memory Device Speed Name memoryDeviceSpeed Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.15 Description Defines the speed in nanoseconds of the memory device. A zero (0) indicates that the speed is unknown. Syntax DellUnsigned32BitRange Access Read-only Device Group 289 Memory Device Total Bus Width Name memoryDeviceTotalBusWidth Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.16 Description Defines the total number of bits, including ECC, used by the memory device. Syntax DellUnsigned32BitRange Access Read-only Memory Device Total Data Bus Width Name memoryDeviceTotalDataBusWidth Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.17 Description Defines the total number of data bits used by the memory device. Syntax DellUnsigned32BitRange Access Read-only Memory Device Correctable Memory Event Count NOTE: "Memory Device Failure Modes" on page 291 has now replaced this attribute. Memory Device Correctable Memory Event Count should no longer be used. If you use the Memory Device Correctable Memory Event Count attribute, the value returned is always zero, and using the attribute has no effect. Name memoryDeviceSingleBitErrorCount Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.18 Description Defines the total number of Correctable Memory Events detected by the memory device. Syntax DellSigned32BitRange Access Read-only 290 Device Group Memory Device Uncorrectable Memory Event Count NOTE: "Memory Device Failure Modes" on page 291 has now replaced this attribute. Memory Device Uncorrectable Memory Event Count should no longer be used. If you use the Memory Device Uncorrectable Memory Event Count attribute, the value returned is always zero, and using the attribute has no effect. Name memoryDeviceMultiBitErrorCount Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.19 Description Defines the total number of Uncorrectable Memory Events detected by the memory device. Syntax DellSigned32BitRange Access Read-only Memory Device Failure Modes Name memoryDeviceFailureModes Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.20 Description Defines the failure modes of the memory device when the memoryDeviceStatus attribute is not OK. It is a bit field that can be used to report more than one type of failure mode by using a combination of the defined bit masks. Syntax DellMemoryDeviceFailureModes Access Read-only Memory Device Manufacturer Name Name memoryDeviceManufacturerName Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.21 Description Defines the manufacturer of the memory device. Syntax DellString Access Read-only Device Group 291 Memory Device Part Number Name Name memoryDevicePartNumberName Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.22 Description Defines the manufacturer's part number for the memory device. Syntax DellString Access Read-only Memory Device Serial Number Name Name memoryDeviceSerialNumberName Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.23 Description Defines the serial number of the memory device. Syntax DellString Access Read-only Memory Device Asset Tag Name Name memoryDeviceAssetTagName Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.24 Description Defines the asset tag of the memory device. Syntax DellString Access Read-only Memory Device Speed Name Name memoryDeviceSpeedName Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.25 Description This attribute defines the speed of the memory device in string format with units specified in string. Syntax DellString Access Read-only 292 Device Group Memory Device Mapped Address Table Name memoryDeviceMappedAddressTable Object ID 1.3.6.1.4.1.674.10892.1.1100.60 Description Defines the Memory Device Mapped Address Table. Syntax SEQUENCE OF MemoryDeviceMappedAddressTableEntry Access Not accessible Memory Device Mapped Address Table Entry Name memoryDeviceMappedAddressTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1 Description Defines the Memory Device Mapped Address Table entry. Syntax MemoryDeviceMappedAddressTableEntry Access Not accessible Index memoryDeviceMappedAddresschassisIndex, memoryDeviceMappedAddressIndex Memory Device Mapped Address Chassis Index Name memoryDeviceMappedAddresschassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Device Group 293 Memory Device Mapped Address Index Name memoryDeviceMappedAddressIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.2 Description Defines the index (one-based) of the memory device mapped address in this chassis. Syntax DellObjectRange Access Read-only Memory Device Mapped Address State Capabilities Name memoryDeviceMappedAddressStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.3 Description Defines the capabilities of the memory device mapped address. Syntax DellStateCapabilities Access Read-only Memory Device Mapped Address State Settings Name memoryDeviceMappedAddressStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.4 Description Defines the state of the memory device mapped address. Syntax DellStateSettings Access Read-write Memory Device Mapped Address Status Name memoryDeviceMappedAddressStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.5 Description Defines the status of the memory device mapped address. Syntax DellStatus Access Read-only 294 Device Group Memory Device Index Reference Name memoryDeviceIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.6 Description Defines the index of the memory device(s) associated with this memory device mapped address. Syntax DellObjectRange Access Read-only Memory Device Mapped Address Row Position Name memoryDeviceMappedAddressRowPosition Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.7 Description Defines the position of the referenced memory in a row of the memory device mapped address. Syntax DellUnsigned32BitRange Access Read-only Memory Device Mapped Address Interleave Position Name memoryDeviceMappedAddressInterleavePosition Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.8 Description Defines the position of the referenced memory in an interleave of the memory device mapped address. Syntax DellUnsigned32BitRange Access Read-only Device Group 295 Memory Device Mapped Address Interleave Depth Name memoryDeviceMappedAddressInterleaveDepth Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.9 Description Defines the maximum number of consecutive rows from the referenced memory device that are accessed in a single interleaved transfer in the memory device mapped address. Syntax DellUnsigned32BitRange Access Read-only Memory Device Mapped Address Starting Address Name memoryDeviceMappedAddressStartingAddress Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.10 Description Defines the physical starting address in KB of the memory device mapped address. Syntax DellUnsigned64BitRange Access Read-only Memory Device Mapped Address Ending Address Name memoryDeviceMappedAddressEndingAddress Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.11 Description Defines the physical ending address in KB of the memory device mapped address. Syntax DellUnsigned64BitRange Access Read-only Generic Device Table Name genericDeviceTable Object ID 1.3.6.1.4.1.674.10892.1.1100.70 Description Defines the Generic Device Table. Syntax SEQUENCE OF GenericDeviceTableEntry Access Not accessible 296 Device Group Generic Device Table Entry Name genericDeviceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.70.1 Description Defines the Generic Device Table entry. Syntax GenericDeviceTableEntry Access Not accessible Index genericDevicechassisIndex, genericDeviceIndex Generic Device Chassis Index Name genericDevicechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.70.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Generic Device Index Name genericDeviceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.70.1.2 Description Defines the index of the generic device in this chassis. Syntax DellObjectRange Access Read-only Generic Device State Capabilities Name genericDeviceStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1100.70.1.3 Description Defines the capabilities of the generic device. Syntax DellStateCapabilities Access Read-only Device Group 297 Generic Device State Settings Name genericDeviceStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1100.70.1.4 Description Defines the state of the generic device. Syntax DellStateSettings Access Read-write Generic Device Status Name genericDeviceStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.70.1.5 Description Defines the status of the generic device. Syntax DellStatus Access Read-only Generic Device System Slot Index Reference Name genericDeviceSystemSlotIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.70.1.6 Description Defines the index of the system slot into which this generic device is plugged. Syntax DellObjectRange Access Read-only Generic Device Type Name genericDeviceType Object ID 1.3.6.1.4.1.674.10892.1.1100.70.1.7 Description Defines the type of the generic device. Syntax DellGenericDeviceType (See Table 14-18) Access Read-only 298 Device Group Generic Device Name Name genericDeviceName Object ID 1.3.6.1.4.1.674.10892.1.1100.70.1.8 Description Defines the name of the generic device. Syntax DellString Access Read-only PCI Device Table Name pCIDeviceTable Object ID 1.3.6.1.4.1.674.10892.1.1100.80 Description Defines the PCI Device Detail Table. Syntax SEQUENCE OF PCIDeviceTableEntry Access Not accessible PCI Device Table Entry Name pCIDeviceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1 Description Defines the PCI Device Table entry. Syntax Not accessible Access PCIDeviceTableEntry Index pCIDevicechassisIndex, pCIDeviceIndex PCI Device Chassis Index Name pCIDevicechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.1 Description Defines the index (one-based) of this chassis. Syntax Read-only Access DellObjectRange Device Group 299 PCI Device Index Name pCIDeviceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.2 Description Defines the index (one-based) of the PCI device in this chassis. Syntax DellObjectRange Access Read-only PCI Device State Capabilities Name pCIDeviceStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.3 Description Defines the capabilities of the PCI device. Syntax DellStateCapabilities Access Read-only PCI Device State Settings Name pCIDeviceStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.4 Description Defines the state of the PCI device. Syntax DellStateSettings Access Read-write PCI Device Status Name pCIDeviceStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.5 Description Defines the status of the PCI device. Syntax DellStatus Access Read-only 300 Device Group PCI Device System Slot Index Reference Name pCIDeviceSystemSlotIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.6 Description Defines the index number of the system slot that this PCI device is in. Syntax DellObjectRange Access Read-only PCI Device Data Bus Width Name pCIDeviceDataBusWidth Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.7 Description Defines the bus width of the PCI device in this chassis. Syntax DellUnsigned32BitRange Access Read-only PCI Device Manufacturer Name Name pCIDeviceManufacturerName Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.8 Description Defines the name of the PCI device manufacturer. Syntax DellString Access Read-only PCI Device Description Name Name pCIDeviceDescriptionName Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.9 Description Defines the descriptive name of the PCI device. Syntax DellString Access Read-only Device Group 301 PCI Device Speed Name pCIDeviceSpeed Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.10 Description Defines the bus speed in MHz of the PCI device in this chassis. A zero (0) indicates that the speed is unknown. Syntax DellUnsigned32BitRange Access Read-only PCI Device Adapter Fault Name pCIDeviceAdapterFault Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.11 Description Defines whether the PCI device in this chassis has detected a fault. Syntax DellBoolean Access Read-only PCI Device Configuration Space Table Name pCIDeviceConfigurationSpaceTable Object ID 1.3.6.1.4.1.674.10892.1.1100.82 Description Defines the PCI Device Configuration Table. Syntax SEQUENCE OF PCIDeviceConfigurationSpaceTableEntry Access Not accessible PCI Device Configuration Space Table Entry Name pCIDeviceConfigurationSpaceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.82.1 Description Defines the PCI Device Configuration Table entry. Syntax PCIDeviceConfigurationSpaceTableEntry Access Not accessible Index pCIDeviceConfigurationSpacechassisIndex, pCIDeviceConfigurationSpaceIndex 302 Device Group PCI Device Configuration Space Chassis Index Name pCIDeviceConfigurationSpacechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.82.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only PCI Device Configuration Space Index Name pCIDeviceConfigurationSpaceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.82.1.2 Description Defines the index (one-based) of the PCI device configuration in this chassis. Syntax DellObjectRange Access Read-only PCI Device Configuration Space State Capabilities Name pCIDeviceConfigurationSpaceStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1100.82.1.3 Description Defines the capabilities of the PCI device configuration. Syntax DellStateCapabilities Access Read-only PCI Device Configuration Space State Settings Name pCIDeviceConfigurationSpaceStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1100.82.1.4 Description Defines the state of the PCI device configuration. Syntax DellStateSettings Access Read-write Device Group 303 PCI Device Configuration Space Status Name pCIDeviceConfigurationSpaceStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.82.1.5 Description Defines the status of the PCI device configuration. Syntax DellStatus Access Read-only PCI Device Index Reference Name pCIDeviceIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.82.1.6 Description Defines the index number of PCI device that this configuration applies to. Syntax DellObjectRange Access Read-only PCI Device Configuration Space Bus Number Name pCIDeviceConfigurationSpaceBusNumber Object ID 1.3.6.1.4.1.674.10892.1.1100.82.1.7 Description Defines the bus number of the PCI device configuration in this chassis. Syntax DellUnsigned32BitRange Access Read-only PCI Device Configuration Space Device Number Name pCIDeviceConfigurationSpaceDeviceNumber Object ID 1.3.6.1.4.1.674.10892.1.1100.82.1.8 Description Defines the device number of the PCI device in this chassis. Syntax DellUnsigned32BitRange Access Read-only 304 Device Group PCI Device Configuration Space Function Number Name pCIDeviceConfigurationSpaceFunctionNumber Object ID 1.3.6.1.4.1.674.10892.1.1100.82.1.9 Description Defines the function number of the PCI device in this chassis. Syntax DellUnsigned32BitRange Access Read-only PCI Device Configuration Space Header Name pCIDeviceConfigurationSpaceHeader Object ID 1.3.6.1.4.1.674.10892.1.1100.82.1.10 Description Defines the common configuration space header of the PCI device. Syntax Octet String (SIZE(0..1025)) Access Read-only Network Device Table Name networkDeviceTable Object ID 1.3.6.1.4.1.674.10892.1.1100.90 Description Defines the Network Device Table. Syntax SEQUENCE OF NetworkDeviceTableEntry Access Not accessible Network Device Table Entry Name networkDeviceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1 Description Defines the Network Device Table Entry. Syntax NetworkDeviceTableEntry Access Not accessible Index networkDeviceChassisIndex, networkDeviceIndex Device Group 305 Network Device Chassis Index Name networkDeviceChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.1 Description Defines the index (one-based) of the chassis that contains the network device. Syntax DellObjectRange Access Read-only Network Device Index Name networkDeviceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.2 Description Defines the index (one-based) of the network device. Syntax DellObjectRange Access Read-only Network Device Status Name networkDeviceStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.3 Description Defines the status of the network device. Syntax DellStatus Access Read-only Network Device Connection Status Name networkDeviceConnectionStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.4 Description Defines the connection status of the network device. Syntax DellNetworkDeviceConnectionStatus (see Table 14-20) Access Read-only 306 Device Group Network Device Description Name Name networkDeviceDescriptionName Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.5 Description Defines the description of the network device. Syntax DellString Access Read-only Network Device Product Name Name networkDeviceProductName Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.6 Description Defines the product name of the network device. Syntax DellString Access Read-only Network Device Vendor Name Name networkDeviceVendorName Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.7 Description Defines the name of the vendor of the network device. Syntax DellString Access Read-only Network Device Service Name Name networkDeviceServiceName Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.8 Description Defines the service name of the network device. Syntax DellString Access Read-only Device Group 307 Network Device Driver Image Path Name Name networkDeviceDriverImagePathName Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.9 Description Defines the path to the binary image of the driver for the network device. Syntax DellString Access Read-only Network Device Driver Version Name Name networkDeviceDriverVersionName Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.10 Description Defines the version of the driver for the network device. Syntax DellString Access Read-only Network Device IP Address Name networkDeviceIPAddress Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.11 Description Defines the IP address of the network device. Syntax IpAddress Access Read-only Network Device IP Subnet Mask Name networkDeviceIPSubnetMask Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.12 Description Defines the IP subnet mask for the IP address currently assigned to the network device. Syntax IpAddress Access Read-only 308 Device Group Network Device Default Gateway IP Address Name networkDeviceDefaultGatewayIPAddress Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.13 Description Defines the IP address of the default gateway for the network device. Syntax IpAddress Access Read-only Network Device DHCP Server IP Address Name networkDeviceDHCPServerIPAddress Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.14 Description Defines the IP address of the DHCP server that was used to obtain the IP address of the network device if DHCP was used to configure the network device. Syntax IpAddress Access Read-only Network Device Current MAC Address Name networkDeviceCurrentMACAddress Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.15 Description Defines the current MAC address of the network device. Syntax DellMACAddress Access Read-only Network Device Permanent MAC Address Name networkDevicePermanentMACAddress Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.16 Description Defines the permanent MAC address of the network device. Syntax DellMACAddress Access Read-only Device Group 309 Network Device PCI Bus Number Name networkDevicePCIBusNumber Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.17 Description Defines the PCI bus number of the network device. Syntax DellUnsigned8BitRange Access Read-only Network Device PCI Device Number Name networkDevicePCIDeviceNumber Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.18 Description Defines the PCI device number of the network device. Syntax DellUnsigned8BitRange Access Read-only Network Device PCI Function Number Name networkDevicePCIFunctionNumber Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.19 Description Defines the PCI function number of the network device. Syntax DellUnsigned8BitRange Access Read-only Network Device IRQ Name networkDeviceIRQ Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.20 Description Defines the interrupt request number of the network device. Syntax DellUnsigned32BitRange Access Read-only 310 Device Group Network Device Base IO Port Address Name networkDeviceBaseIOPortAddress Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.21 Description Defines the base input/outport port address of the network device. Syntax DellUnsigned32BitRange Access Read-only Network Device Teaming Flags Name networkDeviceTeamingFlags Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.22 Description Defines the teaming features of the network device. Syntax DellNetworkDeviceTeamingFlags (see Table 14-21) Access Read-only Network Device TOE Capability Flags Name networkDeviceTOECapabilityFlags Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.23 Description Defines the TCP/IP Offload Engine (TOE) capability flags of the network device. Syntax DellNetworkDeviceTOECapabilityFlags (see Table 14-22) Access Read-only Network Device TOE Enabled Name networkDeviceTOEEnabled Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.24 Description Defines if TOE is enabled for the network device. Syntax DellBoolean Access Read-only Device Group 311 Network Device RDMA Capability Flags Name networkDeviceRDMACapabilityFlags Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.25 Description Defines the Remote Direct Memory Access (RDMA) capability flags of the network device. Syntax DellNetworkDeviceRDMACapabilityFlags (see Table 14-23) Access Read-only Network Device RDMA Enabled Name networkDeviceRDMAEnabled Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.26 Description Defines if RDMA is enabled for the network device. Syntax DellBoolean Access Read-only Network Device iSCSI Capability Flags Name networkDeviceiSCSICapabilityFlags Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.27 Description Defines the Internet Small Computer System Interface (iSCSI) capability flags of the network device. Syntax DellNetworkDeviceiSCSICapabilityFlags (see Table 14-24) Access Read-only Network Device iSCSI Enabled Name networkDeviceiSCSIEnabled Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.28 Description Defines if iSCSI is enabled for the network device. Syntax DellBoolean Access Read-only 312 Device Group Managed System Services Device Table Name managedSystemServicesDeviceTable Object ID 1.3.6.1.4.1.674.10892.1.1100.100 Description Defines the Managed System Services Device Table. Syntax Sequence of ManagedSystemServicesDeviceTable Access Not accessible Managed System Services Device Table Entry Name managedSystemServicesDeviceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.100.1 Description Defines the managed system services device table entry. Syntax ManagedSystemServicesDeviceTableEntry Access Not accessible Index managedSystemServicesDeviceChassisIndex, managedSystemServicesDeviceIndex Managed System Services Device Chassis Index Name managedSystemServicesDeviceChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.100.1.1 Description Defines the index (one-based) of the chassis that contains the managed system services device. Syntax DellObjectRange Access Read-only Device Group 313 Managed System Services Device Index Name managedSystemServicesDeviceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.100.1.2 Description Defines the index (one-based) of the managed system services device. Syntax DellObjectRange Access Read-only Managed System Services Device Status Name managedSystemServicesDeviceStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.100.1.3 Description Defines the status of the managed system services device. Syntax DellStatus Access Read-only Managed System Services Device Type Name managedSystemServicesDeviceType Object ID 1.3.6.1.4.1.674.10892.1.1100.100.1.4 Description Defines the type of the managed system services device. Syntax DellManagedSystemServicesDeviceType. See Table 14-25 Access Read-only 314 Device Group Managed System Services Device Storage Present Name managedSystemServicesDeviceStoragePresent Object ID 1.3.6.1.4.1.674.10892.1.1100.100.1.5 Description Defines whether storage is present on the managed system services device. Syntax DellBoolean Access Read-only Managed System Services Device Storage Size Name managedSystemServicesDeviceStorageSize Object ID 1.3.6.1.4.1.674.10892.1.1100.100.1.6 Description Defines the size in Megabytes (MB) of the storage present on the managed system services device. Syntax DellUnsigned32BitRange Access Read-only SD Card Unit Table Name sdCardUnitTable Object ID 1.3.6.1.4.1.674.10892.1.1100.110 Description Defines the SD Card Unit Table. Syntax SEQUENCE OF SdCardUnitTableEntry Access Not accessible SD Card Unit Table Entry Name sdCardUnitTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.110.1 Description Defines the SD Card Unit Table Entry. Syntax SdCardUnitTableEntry Access Not accessible Device Group 315 Name sdCardUnitTableEntry Index sdCardUnitChassisIndex, sdCardUnitIndex SD Card Unit Chassis Index Name sdCardUnitChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.110.1.1 Description Defines the index (one-based) of the chassis that contains the SD Card unit. Syntax DellObjectRange Access Read-only SD Card Unit Index Name sdCardUnitIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.110.1.2 Description Defines the index (one-based) of the SD Card unit. Syntax DellObjectRange Access Read-only SD Card Unit State Capabilities Name sdCardUnitStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1100.110.1.3 Description Defines the state capabilities of the SD Card unit. Syntax DellStateCapabilities Access Read-only SD Card Unit State Settings Name sdCardUnitStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1100.110.1.4 316 Device Group Name sdCardUnitStateSettings Description Defines the state settings of the SD Card unit. Syntax DellStateSettings Access Read-only SD Card Unit Redundancy Status Name sdCardUnitRedundancyStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.110.1.5 Description Defines the redundancy status of the SD Card unit. Syntax DellStatusRedundancy Access Read-only SD Card Unit Count For Redundancy Name sdCardUnitCountForRedundancy Object ID 1.3.6.1.4.1.674.10892.1.1100.110.1.6 Description Defines the total number of SD Card devices required for this SD Card unit to have full redundancy. Syntax DellObjectRange Access Read-only SD Card Unit Name Name sdCardUnitName Object ID 1.3.6.1.4.1.674.10892.1.1100.110.1.7 Description Defines the name of the SD Card unit. Syntax DellString Access Read-only Device Group 317 SD Card Unit Status Name sdCardUnitStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.110.1.8 Description Defines the status of the SD Card unit. Syntax DellStatus Access Read-only SD Card Device Table Name sdCardDeviceTable Object ID 1.3.6.1.4.1.674.10892.1.1100.112 Description Defines the SD Card Device Table. Syntax SEQUENCE OF SdCardDeviceTableEntry Access Not accessible SD Card Device Table Entry Name sdCardDeviceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1 Description Defines the SD Card Device Table Entry. Syntax SdCardDeviceTableEntry Access Not accessible Index sdCardDeviceChassisIndex, sdCardDeviceIndex SD Card Device Chassis Index Name sdCardDeviceChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.1 Description Defines the index (one-based) of the chassis that contains the SD Card device. Syntax DellObjectRange 318 Device Group Name sdCardDeviceChassisIndex Access Read-only SD Card Device Index Name sdCardDeviceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.2 Description Defines the index (one-based) of the SD Card device. Syntax DellObjectRange Access Read-only SD Card Device Status Name sdCardDeviceStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.3 Description Defines the status of the SD Card device. Syntax DellStatus Access Read-only SD Card Device Type Name sdCardDeviceType Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.4 Description Defines the type of the SD Card device. Syntax DellSDCardDeviceType Access Read-only SD Card Device Config Capabilities Name sdCardDeviceConfigCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.5 Description Defines the configuration capabilities of the SD Card device. Syntax DellSDCardDeviceConfigCapabilities Device Group 319 Name sdCardDeviceConfigCapabilities Access Read-only SD Card Device Config Settings Name sdCardDeviceConfigSettings Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.6 Description Defines the configuration settings of the SD Card device. Syntax DellSDCardDeviceConfigSettings Access Read-only SD Card Device Location Name Name sdCardDeviceLocationName Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.7 Description Defines the location of the SD Card device. Syntax DellString Access Read-only SD Card Device Card Present Name sdCardDeviceCardPresent Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.8 Description Defines whether the SD Card is present for the SD Card device. Syntax DellBoolean Access Read-only SD Card Device Card State Name sdCardDeviceCardState Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.9 Description Defines the state of the SD Card. Syntax DellSDCardDeviceCardState 320 Device Group Name sdCardDeviceCardState Access Read-only SD Card Device Card Storage Size Name sdCardDeviceCardStorageSize Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.10 Description Defines the storage size in MB (megabytes) of the SD card for the SD Card device. Syntax DellUnsigned32BitRange Access Read-only SD Card Device Unit Index Reference Name sdCardDeviceUnitIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.11 Description Defines the index to the associated SD Card unit if the SD Card device is part of a SD Card unit. Syntax DellObjectRange Access Read-only Device Group 321 SD Card Device Card Available Storage Size Name sdCardDeviceCardAvailableStorageSize Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.12 Description Defines the available storage size in MB (megabytes) of the SD card for the SD card device. Syntax DellSigned32BitRange Access Read-only SD Card Device Card Licensed Name sdCardDeviceCardLicensed Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.13 Description Defines whether the SD card is licensed by the system vendor. Syntax DellSDCardDeviceCardLicensed Access Read-only Device Group Variable Values This section includes definitions for server administrator-specific variable values used in this section. Table 14-1. Pointing Device Type Variable Name: DellPointingDeviceType Data Type: Integer Possible Data Values Meaning of Data Value deviceTypeIsOther(1) Device type is not one of the following: deviceTypeIsUnknown(2) Device type is unknown. deviceTypeIsAMouse(3) Device type is a mouse. deviceTypeIsATrackBall(4) Device type is a track ball. deviceTypeIsATrackPoint(5) Device type is a track point. deviceTypeIsAGlidePoint(6) Device type is a glide point. 322 Device Group Table 14-1. Pointing Device Type (continued) Variable Name: DellPointingDeviceType Data Type: Integer Possible Data Values Meaning of Data Value deviceTypeIsATouchPad(7) Device type is a touch pad. Table 14-2. Processor Device Status State Variable Name: DellProcessorDeviceStatusState Data Type: Integer Possible Data Values Meaning of Data Value other(1) Processor device type is not one of the following: unknown(2) Device type is unknown. enabled(3) Device is enabled. userDisabled(4) Device is disabled by the user. biosDisabled(5) Device has its BIOS disabled. idle(6) Device is idle. Table 14-3. Processor Device Status Reading Variable Name: DellProcessorDeviceStatusReading Data Type: Integer NOTE: These values are bit masks, so combination values are possible. Possible Data Values Meaning of Data Value internalError(1) The processor experienced an internal error thermalTrip(2) The processor experienced a thermal trip configurationError(32) The processor experienced a configuration error processorPresent(128) The processor is present Device Group 323 Table 14-3. Processor Device Status Reading (continued) Variable Name: DellProcessorDeviceStatusReading Data Type: Integer NOTE: These values are bit masks, so combination values are possible. Possible Data Values Meaning of Data Value processorDisabled(256) The processor is disabled terminatorPresent(512) The terminator is Present processorThrottled(1024) The processor is throttled Table 14-4. Processor Device Type Variable Name: DellProcessorDeviceType Data Type: Integer Possible Data Values Meaning of Data Value deviceTypeIsOther(1) The processor device type is not one of the following values: deviceTypeIsUnknown(2) The processor device type is unknown. deviceTypeIsCPU(3) The processor device type is a central processing unit. deviceTypeIsMathProcessor(4) The processor device type is a math processor. deviceTypeIsDSP(5) The processor device type is a digital signal processor. deviceTypeIsAVideoProcessor(6) The processor device is a video processor. 324 Device Group Table 14-5. Processor Upgrade Information Variable Name: DellProcessorUpgradeInformation Data Type: Integer Possible Data Values Meaning of Data Value processorUpgradeIsOther(1) The upgrade device type is not one of the following: processorUpgradeIsUnknown(2) Upgrade device type is unknown. processorUpgradeIsByDaughterBoard(3) Upgrade device is on a daughter board. processorUpgradeIsByZIFSocket(4) Upgrade device is in a zero insertion force (ZIF) socket. processorUpgradeIsByReplacement(5) Upgrade device is a replacement. processorUpgradeIsNone(6) There is no upgrade device. processorUpgradeIsByLIFSocket(7) Upgrade device is in a low insertion force (LIF) socket. processorUpgradeIsBySlot1(8) Upgrade device is a SLOT 1 processor. processorUpgradeIsBySlot2(9) Upgrade device is a SLOT 2 processor. processorUpgradeIsBy370PinSocket(10) Upgrade device is a 370 pin socket. processorUpgradeIsBySlotA(11) Upgrade is by Slot A. processorUpgradeIsBySlotM(12) Upgrade is by Slot M. processorUpgradeIsByScoket423(13) Upgrade is by Socket 423. processorUpgradeIsBySocketA(14) Upgrade is by Socket A (Socket 462). processorUpgradeIsBySocket478(15) Upgrade is by Socket 478. processorUpgradeIsBySocket754(16) Upgrade is by Socket 754. processorUpgradeIsBySocket940(17) Upgrade is by Socket 940. Device Group 325 Table 14-5. Processor Upgrade Information (continued) Variable Name: DellProcessorUpgradeInformation Data Type: Integer Possible Data Values Meaning of Data Value processorUpgradeIsBySocket939(18) Upgrade is by Socket 939. processorUpgradeIsBySocketmPGA604(19) Upgrade is by Socket mPGA604. processorUpgradeIsBySocketLGA771(20) Upgrade is by Socket LGA771. processorUpgradeIsBySocketLGA775(21) Upgrade is by Socket LGA775. processorUpgradeIsBySocketS1(22) Upgrade is by Socket S1. processorUpgradeIsBySocketAM2(23) Upgrade is by Socket AM2. processorUpgradeIsBySocketF(24) Upgrade is by Socket F (1207). processorUpgradeIsBySocketLGA1366(25) Upgrade is by Socket LGA1366. Table 14-6. Processor Device Family Variable Name: DellProcessorDeviceFamily Data Type: Integer Possible Data Values Meaning of Data Value deviceFamilyIsOther(1) The processor family is not one of the following values. deviceFamilyIsUnknown(2) The processor family is unknown. deviceFamilyIs8086(3) The processor family is 8086. deviceFamilyIs80286(4) The processor family is 80286. deviceFamilyIs80386(5) The processor family is 80386. deviceFamilyIs80486(6) The processor family is 80486. deviceFamilyIS8087(7) The processor family is 8087. 326 Device Group Table 14-6. Processor Device Family (continued) Variable Name: DellProcessorDeviceFamily Data Type: Integer Possible Data Values Meaning of Data Value deviceFamilyIs80287(8) The processor family is 80287. deviceFamilyIs80387(9) The processor family is 80387. deviceFamilyIs80487(10) The processor family is 80487. deviceFamilyIsPentium(11) The processor family is Intel Pentium. deviceFamilyIsPentiumPro(12) The processor family is Pentium Pro. deviceFamilyIsPentium2(13) The processor family is Pentium II. deviceFamilyIsPentiumMMX(14) The processor family is Pentium MMX. deviceFamilyIsCeleron(15) The processor family is Celeron. deviceFamilyIsXeon(16) The processor family is Xeon. deviceFamilyIsPentium3(17) The processor family is Pentium III. deviceFamilyIsPentium3Xeon(18) The processor family is Pentium III Xeon. deviceFamilyIsPentium3Step(19) The processor family is Pentium III Speed Step. deviceFamilyIsPentiumItanium (20) The processor family is Itanium. deviceFamilyIsIntelXeon(21) The processor family is Intel Xeon. deviceFamilyIsPentium4(22) The processor family is Pentium 4. deviceFamilyIsIntelXeonMP(23) The processor family is Intel Xeon MP. deviceFamilyIsIntelItanium2(24) The processor family is Intel Itanium 2. deviceFamilyIsK5(25) The processor family is K5. deviceFamilyIsK6(26) The processor family is K6. deviceFamilyIsK6-2(27) The processor family is K6-2. deviceFamilyIsK6-3(28) The processor family is K6-3. deviceFamilyIsAMDAthlon(29) The processor family is AMD Athlon. deviceFamilyIsAMD2900(30) The processor family is AMD2900. Device Group 327 Table 14-6. Processor Device Family (continued) Variable Name: DellProcessorDeviceFamily Data Type: Integer Possible Data Values Meaning of Data Value deviceFamilyIsK6-2Plus(31) The processor family is K6-2+. deviceFamilyIsPowerPC(32) The processor family is Power PC. deviceFamilyIsPowerPC601(33) The processor family is Power PC 601. deviceFamilyIsPowerPC603(34) The processor family is Power PC 603. deviceFamilyIsPowerPC603Plus (35) The processor family is Power PC 603+. deviceFamilyIsPowerPC604(36) The processor family is Power PC 604. deviceFamilyIsPowerPC620(37) The processor family is Power PC 620. deviceFamilyIsPowerPCx704(38) The processor family is Power PC x704. deviceFamilyIsPowerPC750(39) The processor family is Power PC 750. deviceFamilyIsIntelCoreDuo(40) The processor family is Intel Core Duo. deviceFamilyIsIntelCoreDuoMobi The processor family is Intel Core Duo le(41) mobile. deviceFamilyIsIntelCoreSoloMob The processor family is Intel Core Solo ile(42) mobile. deviceFamilyIsIntelAtom(43) The processor family is Intel Atom. deviceFamilyIsAlpha(48) The processor family is Alpha. deviceFamilyIsAlpha21064(49) The processor family is Alpha 21064. deviceFamilyIsAlpha21066(50) The processor family is Alpha 21066. deviceFamilyIsAlpha21164(51) The processor family is Alpha 21164. deviceFamilyIsAlpha21164PC(52) The processor family is Alpha 21164PC. deviceFamilyIsAlpha21164a(53) The processor family is Alpha 21164a. deviceFamilyIsAlpha21264(54) The processor family is Alpha 21264. deviceFamilyIsAlpha21364(55) The processor family is Alpha 21364. 328 Device Group Table 14-6. Processor Device Family (continued) Variable Name: DellProcessorDeviceFamily Data Type: Integer Possible Data Values Meaning of Data Value deviceFamilyIsAMDTurionIIUltra The processor family is AMD Turion II DualMobileM(56) Ultra Dual-Core Mobile M Processor Family. deviceFamilyIsAMDTurionIIDualM The processor family is AMD Turion II obileM(57) Dual-Core Mobile M Processor Family. deviceFamilyIsAMDAthlonIIDualM The processor family is AMD Athlon II obileM(58) Dual-Core Mobile M Processor Family. deviceFamilyIsAMDOpteron6100 (59) The processor family is AMD Opteron 6100 Series Processor. deviceFamilyIsAMDOpteron4100 (60) The processor family is AMD Opteron 4100 Series Processor. deviceFamilyIsAMDOpteron6200 (61) The processor family is AMD Opteron 6200 Series Processor. deviceFamilyIsAMDOpteron4200 (62) The processor family is AMD Opteron 4200 Series Processor. deviceFamilyIsMIPS(64) The processor family is MIPS. deviceFamilyIsMIPSR4000(65) The processor family is MIPS R4000. deviceFamilyIsMIPSR4200(66) The processor family is MIPS R4200. deviceFamilyIsMIPSR4400(67) The processor family is MIPS R4400. deviceFamilyIsMIPSR4600(68) The processor family is MIPS R4600. deviceFamilyIsMIPSR10000(69) The processor family is MIPS R10000. deviceFamilyIsSPARC(80) The processor family is SPARC. deviceFamilyIsSuperSPARC(81) The processor family is SuperSPARC. deviceFamilyIsmicroSPARCII(82) The processor family is microSPARC II. deviceFamilyIsmicroSPARCIIep (83) The processor family is microSPARC IIep. deviceFamilyIsUltraSPARC(84) The processor family is UltraSPARC. deviceFamilyIsUltraSPARCII(85) The processor family is UltraSPARC II. Device Group 329 Table 14-6. Processor Device Family (continued) Variable Name: DellProcessorDeviceFamily Data Type: Integer Possible Data Values Meaning of Data Value deviceFamilyIsUltraSPARCIIi(86) The processor family is UltraSPARC IIi. deviceFamilyIsUltraSPARCIII(87) The processor family is UltraSPARC III. deviceFamilyIsUltraSPARCIIIi (88) The processor family is UltraSPARC IIIi. deviceFamilyIs68040(96) The processor family is 68040 Family. deviceFamilyIs68xxx(97) The processor family is 68xxx. deviceFamilyIs68000(98) The processor family is 68000. deviceFamilyIs68010(99) The processor family is 68010. deviceFamilyIs68020(100) The processor family is 68020. deviceFamilyIs68030(101) The processor family is 68030. deviceFamilyIsHobbit(112) The processor family is Hobbit. deviceFamilyIsCrusoe5000(120) The processor family is Crusoe 5000. deviceFamilyIsCrusoe3000(121) The processor family is Crusoe 3000. deviceFamilyIsEfficeon8000 (122) The processor family is Efficeon 8000. deviceFamilyIsWeitek(128) The processor family is Weitek. deviceFamilyIsIntelCeleronM(13 The processor family is Intel Celeron 0) M. deviceFamilyIsAMDAthlon64(131) The processor family is AMD Athlon 64. deviceFamilyIsAMDOpteron(132) The processor family is AMD Opteron. deviceFamilyIsAMDSempron(133) The processor family is AMD Sempron. deviceFamilyIsAMDTurion64Mobile The processor family is AMD Turion 64 (134) Mobile Technology. deviceFamilyIsDualCoreAMDOpter The processor family is Dual-Core on(135) AMD Opteron. 330 Device Group Table 14-6. Processor Device Family (continued) Variable Name: DellProcessorDeviceFamily Data Type: Integer Possible Data Values Meaning of Data Value deviceFamilyIsAMDAthlon64X2Dual The processor family is AMD Athlon Core(136) 64 X2 Dual-Core. deviceFamilyIsAMDTurion64X2Mob The processor family is AMD Turion 64 ile(137) X2 Mobile Technology. deviceFamilyIsQuadCoreAMDOpter The processor family is Quad-Core on(138) AMD Opteron. deviceFamilyIsThirdGeneration AMDOpteron(139) The processor family is thirdgeneration AMD Opteron. deviceFamilyIsAMDPhenomFXQuadC The processor family is AMD Phenom ore(140) FX Quad-Core. deviceFamilyIsAMDPhenomX4QuadC The processor family is AMD Phenom ore(141) X4 Quad-Core. deviceFamilyIsAMDPhenomX2DualC The processor family is AMD Phenom ore(142) X2 Dual-Core. deviceFamilyIsAMDAthlonX2DualC The processor family is AMD Athlon ore(143) X2 Dual-Core. deviceFamilyIsPA-RISC(144) The processor family is PA-RISC. deviceFamilyIsPA-RISC8500(145) The processor family is PA-RISC 8500. deviceFamilyIsPA-RISC8000(146) The processor family is PA-RISC 8000. deviceFamilyIsPARISC7300LC(147) The processor family is PA-RISC 7300LC. deviceFamilyIsPA-RISC7200(148) The processor family is PA-RISC 7200. deviceFamilyIsPARISC7100LC(149) The processor family is PA-RISC 7100LC. deviceFamilyIsPA-RISC7100(150) The processor family is PA-RISC 7100. deviceFamilyIsV30(160) The processor family is V30. deviceFamilyIsQuadCoreIntelXeo The processor family is Quad-Core n3200(161) Intel Xeon processor 3200 Series. Device Group 331 Table 14-6. Processor Device Family (continued) Variable Name: DellProcessorDeviceFamily Data Type: Integer Possible Data Values Meaning of Data Value deviceFamilyIsDualCoreIntelXeo The processor family is Dual-Core Intel n3000(162) Xeon processor 3000 Series. deviceFamilyIsQuadCoreIntelXeo The processor family is Quad-Core n5300(163) Intel Xeon processor 5300 Series. deviceFamilyIsDualCoreIntelXeo The processor family is Dual-Core Intel n5100(164) Xeon processor 5100 Series. deviceFamilyIsDualCoreIntelXeo The processor family is Dual-Core Intel n5000(165) Xeon processor 5000 Series. deviceFamilyIsDualCoreIntelXeo The processor family is Dual-Core Intel nLV(166) Xeon processor LV. deviceFamilyIsDualCoreIntelXeo The processor family is Dual-Core Intel nULV(167) Xeon processor ULV. deviceFamilyIsDualCoreIntelXeo The processor family is Dual-Core Intel n7100(168) Xeon processor 7100 Series. deviceFamilyIsQuadCoreIntelXeo The processor family is Quad-Core n5400(169) Intel Xeon processor 5400 Series. deviceFamilyIsQuadCoreIntelXeo The processor family is Quad-Core n(170) Intel Xeon. deviceFamilyIsDualCoreIntelXeo The processor family is Dual-Core Intel n5200(171) Xeon processor 5200 Series. deviceFamilyIsDualCoreIntelXeo The processor family is Dual-Core Intel n7200(172) Xeon processor 7200 Series. deviceFamilyIsQuadCoreIntelXeo The processor family is Quad-Core n7300(173) Intel Xeon processor 7300 Series. deviceFamilyIsQuadCoreIntelXeo The processor family is Quad-Core n7400(174) Intel Xeon processor 7400 Series. deviceFamilyIsMultiCoreIntelXe The processor family is Multi-Core on7400(175) Intel Xeon processor 7400 Series. deviceFamilyIsM1(176) 332 Device Group The processor family is M1. Table 14-6. Processor Device Family (continued) Variable Name: DellProcessorDeviceFamily Data Type: Integer Possible Data Values Meaning of Data Value deviceFamilyIsM2(177) The processor family is M2. deviceFamilyIsIntelPentium4HT (179) The processor family is Intel Pentium 4 HT processor. deviceFamilyIsAS400(180) The processor family is AS400. deviceFamilyIsAMDAthlonXP(182) The processor family is AMD Athlon XP. deviceFamilyIsAMDAthlonMP(183) The processor family is AMD Athlon MP. deviceFamilyIsAMDDuron(184) The processor family is AMD Duron. deviceFamilyIsIntelPentiumM(185) The processor family is Intel Pentium M. deviceFamilyIsIntelCeleronD(186) The processor family is Intel Celeron D. deviceFamilyIsIntelPentiumD(187) The processor family is Intel Pentium D. deviceFamilyIsIntelPentiumExtr The processor family is Intel Pentium eme(188) Processor Extreme Edition. deviceFamilyIsIntelCoreSolo (189) The processor family is Intel Core Solo processor. deviceFamilyIsIntelCore2(190) The processor family is Intel Core 2 processor. deviceFamilyIsIntelCore2Duo (191) The processor family is Intel Core 2 Duo processor. deviceFamilyIsIntelCore2Solo (192) The processor family is Intel Core2 Solo processor. deviceFamilyIsIntelCore2Extrem The processor family is Intel Core2 e(193) Extreme processor. deviceFamilyIsIntelCore2Quad (194) The processor family is Intel Core2 Quad processor. Device Group 333 Table 14-6. Processor Device Family (continued) Variable Name: DellProcessorDeviceFamily Data Type: Integer Possible Data Values Meaning of Data Value deviceFamilyIsIntelCore2Extrem The processor family is Intel Core2 eMobile(195) Extreme mobile processor. deviceFamilyIsIntelCore2DuoMob The processor family is Intel Core2 ile(196) Duo mobile processor. deviceFamilyIsIntelCore2SoloMo The processor family is Intel Core2 bile(197) Solo mobile processor. deviceFamilyIsIntelCorei7(198) The processor family is Intel Core i7 processor. deviceFamilyIsDualCoreIntelCel The processor family is Dual-Core Intel eron(199) Celeron Processor. deviceFamilyIsIBM390(200) The processor family is IBM390. deviceFamilyIsG4(201) The processor family is G4. deviceFamilyIsG5(202) The processor family is G5. deviceFamilyIsESA390G6(203) The processor family is ESA/390 G6. deviceFamilyIszArchitectur (204) The processor family is z/Architectur base. deviceFamilyIsIntelCorei5(205) The processor family is Intel Core i5 processor. deviceFamilyIsIntelCorei3(206) The processor family is Intel Core i3 processor. deviceFamilyIsVIAC7-M(210) The processor family is VIA C7-M. deviceFamilyIsVIAC7-D(211) The processor family is family is VIA C7-D. deviceFamilyIsVIAC7(212) The processor family is VIA C7. deviceFamilyIsVIAEden(213) The processor family is VIA Eden. deviceFamilyIsMultiCoreIntelXe The processor family is Multi-Core on(214) Intel Xeon processor. 334 Device Group Table 14-6. Processor Device Family (continued) Variable Name: DellProcessorDeviceFamily Data Type: Integer Possible Data Values Meaning of Data Value deviceFamilyIsDualCoreIntelXeo The processor family is Dual-Core Intel n3xxx(215) Xeon processor 3xxx Series. deviceFamilyIsQuadCoreIntelXeo The processor family is Quad-Core n3xxx(216) Intel Xeon processor 3xxx Series. deviceFamilyIsVIANano(217) The processor family is VIA Nano. deviceFamilyIsDualCoreIntelXeo The processor family is Dual-Core Intel n5xxx(218) Xeon processor 5xxx Series. deviceFamilyIsQuadCoreIntelXeo The processor family is Quad-Core n5xxx(219) Intel Xeon processor 5xxx Series. deviceFamilyIsDualCoreIntelXeo The processor family is Dual-Core Intel n7xxx(221) Xeon processor 7xxx Series. deviceFamilyIsQuadCoreIntelXeo The processor family is Quad-Core n7xxx(222) Intel Xeon processor 7xxx Series. deviceFamilyIsMultiCoreIntelXe The processor family is Multi-Core on7xxx(223) Intel Xeon processor 7xxx Series. deviceFamilyIsMultiCoreIntelXe The processor family is Multi-Core on3400(224) Intel Xeon processor 3400 Series. deviceFamilyIsEmbeddedAMDOpert The processor family is Embedded onQuadCore(230) AMD Opteron Quad-Core. deviceFamilyIsAMDPhenomTripleC The processor family is AMD Phenom ore(231) Triple-Core. deviceFamilyIsAMDTurionUltraDu The processor family is AMD Turion alCoreMobile(232) Ultra Dual-Core mobile processor. deviceFamilyIsAMDTurionDualCor The processor family is AMD Turion eMobile(233) Dual-Core mobile processor. deviceFamilyIsAMDAthlonDualCor The processor family is AMD Athlon e(234) Dual-Core. deviceFamilyIsAMDSempronSI (235) The processor family is AMD Sempron SI. Device Group 335 Table 14-6. Processor Device Family (continued) Variable Name: DellProcessorDeviceFamily Data Type: Integer Possible Data Values Meaning of Data Value deviceFamilyIsAMDPhenomII(236) The processor family is AMD Phenom II. deviceFamilyIsAMDAthlonII(237) The processor family is AMD Athlon II. deviceFamilyIsSixCoreAMDOptero The processor family is Six-Core AMD n(238) Opteron. deviceFamilyIsAMDSempronM(239) The processor family is AMD Sempron M. deviceFamilyIsi860(250) The processor family is i860. deviceFamilyIsi960(251) The processor family is i960. deviceFamilyIsAMDOpteron6200 (61) The processor family family is AMD Opteron 6200 Series Processor. deviceFamilyIsAMDOpteron4200 (61) The processor family family is AMD Opteron 4200 Series Processor. Table 14-7. Cache Device Type Variable Name: DellCacheDeviceType Data Type: Integer Possible Data Values Meaning of Data Value deviceTypeIsOther(1) System cache type is not one of the following: deviceTypeIsUnknown(2) System cache type is unknown. deviceTypeIsInstruction(3) System cache type is instruction. deviceTypeIsData(4) System cache type is data. deviceTypeIsUnified(5) System cache type is both instruction and data. 336 Device Group Table 14-8. Cache Device Level Variable Name: DellCacheDeviceLevel Data Type: Integer Possible Data Values Meaning of Data Value deviceLevelIsOther(1) Device level is not one of the following: deviceLevelIsUnknown(2) Device level is unknown. deviceLevelIsPrimary(3) Device level is primary. deviceLevelIsSecondary(4) Device level is secondary. deviceLevelIsTertiary(5) Device level is tertiary. Table 14-9. Cache Device Write Policy Variable Name: DellCacheDeviceWritePolicy Data Type: Integer Possible Data Values Meaning of Data Value deviceWritePolicyIsOther(1) Device write policy is not one of the following: deviceWritePolicyIsUnknown(2) Device write policy is unknown. deviceWritePolicyIsWriteBack(3) Device write policy is write back. deviceWritePolicyIsWriteThrough(4) Device write policy is write through. deviceWritePolicyIsVariesByAddress(5) Device write policy varies by address. deviceWritePolicyIsDeterminedByIO(6) Device write policy is determined by I/O query. Device Group 337 Table 14-10. Cache Device Status State Variable Name: DellCacheDeviceStatusState Data Type: Integer Possible Data Values Meaning of Data Value other(1) Device state is not one of the following: unknown(2) Device state is unknown. enabled(3) Device is enabled. userDisabled(4) Device is disabled by the user. biosDisabled(5) Device basic input/output system (BIOS) is disabled. Table 14-11. Cache Device ECC Type Variable Name: DellPointingDeviceType Data Type: Integer Possible Data Values Meaning of Data Value deviceTypeIsOther(1) Device type is not one of the following: deviceTypeIsUnknown(2) Device type is unknown. deviceTypeIsAMouse(3) Device type is a mouse. deviceTypeIsATrackBall(4) Device type is a track ball. deviceTypeIsATrackPoint(5) Device type is a track point. deviceTypeIsAGlidePoint(6) Device type is a glide point. deviceTypeIsATouchPad(7) Device type is a touch pad. Table 14-12. Cache Device Associativity Variable Name: DellCacheDeviceAssociativity Data Type: Integer Possible Data Values Meaning of Data Value deviceAssociativityIsOther(1) Device associativity is not one of the following: 338 Device Group Table 14-12. Cache Device Associativity (continued) Variable Name: DellCacheDeviceAssociativity Data Type: Integer Possible Data Values Meaning of Data Value deviceAssociativityIsUnknown(2) Device associativity is unknown. deviceAssociativityIsDirectMapped(3) Device is direct mapped. deviceAssociativityIsTwoWaySetAsso ciative(4) Device is two-way set associative. deviceAssociativityIsFourWaySetAsso Device is four-way set ciative(5) associative. deviceAssociativityIsFullyAssociative Device is fully associative. (6) deviceAssociativityIsEightWaySetAsso Device is eight-way set ciative(7) associative. deviceAssociativityIsSixteenWaySet Associative(8) Device is sixteen-way set associative. deviceAssociativityIs12WaySetAssoc iative(9) Device is 12-way Set-Associative. deviceAssociativityIs24WaySetAssoc iative(10) Device is 24-way Set-Associative. deviceAssociativityIs32WaySetAssoc iative(11) Device is 32-way Set-Associative. deviceAssociativityIs48WaySetAssoc iative(12) Device is 48-way Set-Associative. deviceAssociativityIs64WaySetAssoc iative(13) Device is 64-way Set-Associative. Device Group 339 Table 14-13. Cache Device Location Variable Name: DellCacheDeviceLocation Data Type: Integer Possible Data Values Meaning of Data Value deviceLocationIsOther(1) Device location is not one of the following: deviceLocationIsUnknown(2) Device location is unknown. deviceLocationIsInternal(3) Device location is internal. deviceLocationIsExternal(4) Device location is external. Table 14-14. Cache Device Static Random-Access Memory (SRAM) Type Variable Name: DellCacheDeviceSRAMType Data Type: Integer Possible Data Values Meaning of Data Value deviceSRAMTypeIsOther(1) Device SRAM type is not one of the following: deviceSRAMTypeIsUnknown(2) Device SRAM type is unknown. deviceSRAMTypeIsNonBurst(3) Device SRAM type is nonburst. deviceSRAMTypeIsBurst(4) Device SRAM type is burst. deviceSRAMTypeIsPipeBurst(5) Device SRAM type is pipeburst. deviceSRAMTypeIsSynchronous(6) Device SRAM type is synchronous. deviceSRAMTypeIsAsynchronous(7) Device SRAM type is asynchronous. Table 14-15. Memory Device Type Form Factor Variable Name: DellMemoryDeviceFormFactor Data Type: Integer Possible Data Values Meaning of Data Value deviceFormFactorIsOther(1) Device form factor is not one of the following: 340 Device Group Table 14-15. Memory Device Type Form Factor (continued) Variable Name: DellMemoryDeviceFormFactor Data Type: Integer Possible Data Values Meaning of Data Value deviceFormFactorIsUnknown(2) Device form factor is unknown. deviceFormFactorIsSIMM(3) Device form factor is SIMM. deviceFormFactorIsSIP(4) Device form factor is SIP. deviceFormFactorIsAChip(5) Device form factor is a chip. deviceFormFactorIsDIP(6) Device form factor is DIP. deviceFormFactorIsZIP(7) Device form factor is ZIP. deviceFormFactorIsAProprietaryCard Device form factor is a proprietary (8) card. deviceFormFactorIsDIMM(9) Device form factor is DIMM. deviceFormFactorIsTSOP(10) Device form factor is TSOP. deviceFormFactorIsARowOfChips(11) Device form factor is a row of chips. deviceFormFactorIsRIMM(12) Device form factor is RIMM. deviceFormFactorIsSODIMM(13) Device form factor is SODIMM. deviceFormFactorIsSRIMM(14) Device form factor is SRIMM. deviceFormFactorIsFBDIMM(15) Device form factor is FB-DIMM. Table 14-16. Memory Device Type Variable Name: DellMemoryDeviceType Data Type: Integer Possible Data Values Meaning of Data Value deviceTypeIsOther(1) Device type is not one of the following: deviceTypeIsUnknown(2) Device type is unknown. deviceTypeIsDRAM(3) Device type is DRAM. deviceTypeIsEDRAM(4) Device type is EDRAM. Device Group 341 Table 14-16. Memory Device Type (continued) Variable Name: DellMemoryDeviceType Data Type: Integer Possible Data Values Meaning of Data Value deviceTypeIsVRAM(5) Device type is VRAM. deviceTypeIsSRAM(6) Device type is SRAM. deviceTypeIsRAM(7) Device type is RAM. deviceTypeIsROM(8) Device type is ROM. deviceTypeIsFLASH(9) Device type is FLASH. deviceTypeIsEEPROM(10) Device type is EEPROM. deviceTypeIsFEPROM(11) Device type is FEPROM. deviceTypeIsEPROM(12) Device type is EPROM. deviceTypeIsCDRAM(13) Device type is CDRAM. deviceTypeIs3DRAM(14) Device type is 3DRAM. deviceTypeIsSDRAM(15) Device type is SDRAM. deviceTypeIsSGRAM(16) Device type is SGRAM. deviceTypeIsRDRAM(17) Device type is RDRAM. deviceTypeIsDDR(18) Device type is DDR. deviceTypeIsDDR2(19) Device type is DDR2. deviceTypeIsDDR2FBDIMM(20) Device type is DDR2 FB-DIMM. deviceTypeIsDDR3(24) Device type is DDR3. deviceTypeIsFBD2(25) Device type is FBD2. 342 Device Group Table 14-17. Memory Device Type Details Variable Name: DellMemoryDeviceTypeDetails Data Type: Integer Possible Data Values Meaning of Data Value deviceTypeDetailIsOther(2) The detailed device type is not one of the following: deviceTypeDetailIsUnknown(4) The detailed device type is unknown. deviceTypeDetailIsFastPaged (8) The detailed device type is fast paged. deviceTypeDetailIsStaticColum The detailed device type is static column. n(16) deviceTypeDetailIsPseudoStati The detailed device type is pseudo-static. c(32) deviceTypeDetailIsRAMBUS(64) The detailed device type is RAMBUS. deviceTypeDetailIsSynchronous The detailed device type is synchronous. (128) deviceTypeDetailIsCMOS(256) The detailed device type is CMOS. deviceTypeDetailIsEDO(512) The detailed device type is EDO. deviceTypeDetailIsWindowDRAM (1024) The detailed device type is Window DRAM. deviceTypeDetailIsCacheDRAM (2048) The detailed device type is Cache DRAM. deviceTypeDetailIsNonVolatile The detailed device type is Non-volatile. (4096) deviceTypeDetailIsRegistered (8192) The detailed device type is registered. deviceTypeDetailIsNonRegister The detailed device type is noned(16384) registered. Device Group 343 Table 14-18. Generic Device Type Variable Name: DellGenericDeviceType Data Type: Integer Possible Data Values Meaning of Data Value deviceTypeIsOther(1) Device type is not one of the following: deviceTypeIsUnknown(2) Device type is unknown. deviceTypeIsAVideoDevice(3) Device type is a video. deviceTypeIsASCSIController(4) Device type is a SCSI controller. deviceTypeIsAnEthernetDevice(5) Device type is Ethernet. deviceTypeIsTokenRingDevice(6) Device type is token ring. deviceTypeIsASoundDevice(7) Device type is sound. Table 14-19. Memory Device Failure Modes Variable Name: DellMemoryDeviceFailureModes Data Type: Integer NOTE: These values are bit masks, so combination values are possible. Possible Data Values Meaning of Data Value (0) Memory device has no faults. eccSingleBitCorrectionWarningRate(1) Memory device has exceeded the Correctable Memory Event warning rate. eccSingleBitCorrectionFailureRate(2) Memory device has exceeded the Correctable Memory Event failure rate. eccMultiBitFault(4) Memory device has encountered an Uncorrectable Memory Event. 344 Device Group Table 14-19. Memory Device Failure Modes (continued) Variable Name: DellMemoryDeviceFailureModes Data Type: Integer NOTE: These values are bit masks, so combination values are possible. Possible Data Values Meaning of Data Value eccSingleBitCorrectionLoggingDisabled(8) Correctable Memory Event logging for memory device has been disabled. deviceDisabledBySpareActivation(16) Memory device is disabled because of spare memory activation. Table 14-20. Network Device Connection Status Variable Name: DellNetworkDeviceConnectionStatus Data Type: Integer Possible Data Values Meaning of Data Value unknown(0) Unable to determine connection status. connected(1) Media reports that device is connected. disconnected(2) Media reports that device is disconnected. driverBad(3) Driver cannot be opened to determine status. driverDisabled(4) Driver is disabled. hardwareInitalizing(10) Hardware is initializing. hardwareResetting(11) Hardware is resetting. hardwareClosing(12) Hardware is closing down. hardwareNotReady(13) Hardware is not ready. Device Group 345 Table 14-21. Network Device Teaming Flags Variable Name: DellNetworkDeviceTeamingFlags Data Type: Integer NOTE: These values are bit fields, so combination values are possible. Possible Data Values Meaning of Data Value undefined(0) Teaming flags are undefined. noTeam(1) Device is not part of any team. teamingEnabled(2) Teaming is enabled. adapterFaultToleranceMode(4) Adapter fault tolerance teaming mode. loadBalancingMode(8) Load balancing teaming mode. Table 14-22. Network Device TOE Capability Flags Variable Name: DellNetworkDeviceTOECapabilityFlags Data Type: Integer NOTE: These values are bit fields, so combination values are possible. Possible Data Values Meaning of Data Value none(0) Querying for TOE capability is not supported. unknown(1) Querying for TOE capability is supported but query returned an error. available(2) Device has TOE capability. notAvailable(4) Device does not have TOE capability. cannotBeDetermined(8) Querying for TOE capability is supported but an error prevented querying. driverNotResponding(16) Querying for TOE capability is supported but driver did not respond to query. 346 Device Group Table 14-23. Network Device RDMA Capability Flags Variable Name: DellNetworkDeviceRDMACapabilityFlags Data Type: Integer NOTE: These values are bit fields, so combination values are possible. Possible Data Values Meaning of Data Value none(0) Querying for RDMA capability is not supported. unknown(1) Querying for RDMA capability is supported but query returned an error. available(2) Device has RDMA capability. notAvailable(4) Device does not have RDMA capability. cannotBeDetermined(8) Querying for RDMA capability is supported but an error prevented querying. driverNotResponding(16) Querying for RDMA capability is supported but driver did not respond to query. Table 14-24. Network Device iSCSI Capability Flags Variable Name: DellNetworkDeviceiSCSICapabilityFlags Data Type: Integer NOTE: These values are bit fields, so combination values are possible. Possible Data Values Meaning of Data Value none(0) Querying for iSCSI capability is not supported. unknown(1) Querying for iSCSI capability is supported but query returned an error. available(2) Device has iSCSI capability. notAvailable(4) Device does not have iSCSI capability. cannotBeDetermined(8) Querying for iSCSI capability is supported but an error prevented querying. driverNotResponding(16) Querying for iSCSI capability is supported but driver did not respond to query. Device Group 347 Table 14-25. Managed System Services Device Type Variable Name: DellManagedSystemServicesDeviceType Data Type: Integer Possible Data Values Meaning of Data Value baseDevice(0) Device type is base device. optionalDevice(1) Device type is optional device. Table 14-26. SD Card Device Type Variable Name: DellSDCardDeviceType Data Type: Integer Possible Data Values Meaning of Data Value other(1) Device type is other. unknown(2) Device type is unknown. hypervisor(3) Device type is Hypervisor. vFlash(4) Device type is Virtual Flash (vFlash.) Table 14-27. SD Card Device Config Capabilities Variable Name: DellSDCardDeviceConfigCapabilities Data Type: Integer NOTE: These values are bit fields, so combination values are possible. Possible Data Values Meaning of Data Value none(0) SD card device has none of the following capabilities. sdCapable(1) SD media can be enabled. vFlashCapable(2) Virtual Flash (vFlash) can be enabled. 348 Device Group Table 14-28. SD Card Device Config Settings Variable Name: DellSDCardDeviceConfigSettings Data Type: Integer NOTE: These values are bit fields, so combination values are possible. Possible Data Values Meaning of Data Value none(0) SD card device has none of the following settings. sdEnabled(1) SD media is enabled. vFlashEnabled(2) Virtual Flash (vFlash) is enabled. Table 14-29. SD Card Device Card State Variable Name: DellSDCardDeviceCardState Data Type: Integer Possible Data Values Meaning of Data Value none(0) SD card state is none of the following states. present(1) Device is present. ipmiReady(2) Device is IPMI ready. fullReady(4) Device is full ready. offline(8) Device is offline. failed(16) Device is failed. active(32) Device is active. bootable(64) Device is bootable. writeProtect(128) Device is write-protected. standby(256) Device is in standby mode. Table 14-30. SD Card Device Card Licensed Variable Name: DellSDCardDeviceCardLicensed Data Type: Integer Possible Data Values Meaning of Data Value unlicensed(0) SD card is not licensed by system vendor. Device Group 349 Variable Name: DellSDCardDeviceCardLicensed Data Type: Integer Possible Data Values Meaning of Data Value licensed(1) SD card is licensed by system vendor. ipmiReady(2) Device is IPMI ready. fullReady(4) Device is full ready. offline(8) Device is offline. failed(16) Device is failed. active(32) Device is active. bootable(64) Device is bootable. writeProtect(128) Device is write-protected. standby(256) Device is in standby mode. 350 Device Group Slot Group 15 The Slot Group provides information about the types of slots that your system supports. This management information base (MIB) group also provides information about the voltages, capabilities, states, and settings that are possible for these slots. System Slot Group Table The System Slot Group defines objects in the System Slot MIB table. System Slot Table The following object sets up the System Slot Table: Name systemSlotTable Object ID 1.3.6.1.4.1.674.10892.1.1200.10 Description Defines the System Slot Table. Syntax IntegerSystemStateTableEntry Access Not accessible System Slot Table Entry Name systemSlotTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1 Description Defines the System Slot Table entry. Syntax IntegerSystemSlotTableEntry Access Not accessible Index systemSlotchassisIndex, systemSlotIndex Slot Group 351 System Slot Chassis Index Name systemSlotchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only System Slot Index Name systemSlotIndex Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.2 Description Defines the index (one-based) of the system slot in this chassis. Syntax DellObjectRange Access Read-only System Slot State Capabilities Unique Name systemSlotStateCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.3 Description Defines the capabilities of the system slot. Syntax DellSystemSlotStateCapabilities (See Table 15-1) Access Read-only System Slot State Settings Unique Name systemSlotStateSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.4 Description Defines the state of the system slot. Syntax DellSystemSlotStateSettings (See Table 15-2) Access Read-only 352 Slot Group System Slot Status Name systemSlotStatus Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.5 Description Defines the status of the system slot. Syntax DellStatus Access Read-only System Slot Current Usage Name systemSlotCurrentUsage Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.6 Description Defines the current usage of the system slot. Syntax DellStatus Access Read-only System Slot Type Name systemSlotType Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.7 Description Defines the type of the system slot. Syntax DellSystemSlotType (See Table 15-3) Access Read-only System Slot External Slot Name Name systemSlotSlotExternalSlotName Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.8 Description Defines the external connector name of the system slot. Syntax DellString Access Read-only Slot Group 353 System Slot Length Name systemSlotLength Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.9 Description Defines the length of the system slot. Syntax DellSystemSlotLength (See Table 15-5) Access Read-only System Slot Slot ID Name systemSlotSlotID Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.10 Description Defines the slot identification number of the system slot. A zero (0) indicates that the slot is embedded on the motherboard. Syntax DellUnsigned32BitRange Access Read-only System Slot Category Name systemSlotCategory Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.11 Description Defines the system slot category. Syntax DellUnsigned32BitRange Access Read-only System Slot Hot-Plug Bus Width Name systemSlotHotPlugBusWidth Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.12 Description Defines the bus width of the hot-plug system slot. Syntax DellSystemSlotHotPlugBusWidth (See Table 15-7) Access Read-only 354 Slot Group System Slot Hot-Plug Slot Speed Name systemSlotHotPlugSlotSpeed Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.13 Description Defines the slot speed in megahertz of the hot-plug system slot. A zero (0) indicates that the slot speed is unknown. Syntax DellUnsigned32BitRange Access Read-only System Slot Hot-Plug Adapter Speed Name systemSlotHotPlugAdapterSpeed Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.14 Description Defines the adapter speed in megahertz of the hot-plug system slot. A zero (0) indicates that the slot speed is unknown. Syntax DellUnsigned32BitRange Access Read-only System Slot Variable Values This section includes definitions for server administrator-specific variable values used in this section. Table 15-1. System Slot State Capabilities Variable Name: DellSystemSlotStateCapabilities Data Type: Integer Possible Data Values Meaning of Data Value systemSlotHotPlugIsUnknown The system slot’s capabilities are unknown. (1) systemSlotHotPlugIsHotPlug The system slot supports hot-plug. gableCapable(2) systemSlotHotPlugCanBePower The system slot power (and corresponding edOn(4) light-emitting diode [LED]) can be powered on. Slot Group 355 Table 15-1. System Slot State Capabilities (continued) Variable Name: DellSystemSlotStateCapabilities Data Type: Integer Possible Data Values Meaning of Data Value systemSlotHotPlugCanSignal The system slot attention state Attention(8) (and corresponding LED) can be set. systemSlotHotPlugCanSignal Power on fault (and corresponding LED) can PowerFault(16) be detected due to a short or overcurrent. systemSlotHotPlugCanSignal Adapter (card) present in slot (may not be AdapterPresent(32) powered) can be detected. systemSlotHotPlugCanSignal The system slot power button can be pressed PowerButtonPressed(64) to signal a toggle of the power state. canSupportAllHotPlugCapabi The system slot can support all lities(126) hot-plug capabilities. systemSlotHotPlugIsUnknown The system slot’s capabilities are unknown. (1) systemSlotCanProvide5Volts The system slot can provide a (128) 5-volt (V) supply. systemSlotCanProvide3Point The system slot can provide a 3.3-V supply. 3Volts(256) systemSlotCanSignalIfShared The system slot’s opening, if shared with (512) another slot, can be detected. systemSlotCanSupportCard16 The system slot can support (1024) PC Card-16. systemSlotCanSupportCardBus The system slot can support CardBus. (2048) systemSlotCanSupportZoomVid The system slot can support Zoom Video. eo(4096) systemSlotCanSupportModem The system slot can support modem RingResume(8192) ring resume. systemSlotCanSupportPMESig The system slot can support Power nal(16384) Management Enable (PME#) signal. canSupportAllSlotCapabilit The system slot can support all ies(32640) slot capabilities. 356 Slot Group Table 15-2. System Slot State Settings Variable Name: DellSystemSlotStateSettings Data Type: Integer Possible Data Values Meaning of Data Value systemSlotHotPlugIsUnknown(1) The system slot’s capabilities are unknown. systemSlotHotPlugIsHotPluggable(2) The system slot supports hot-plug. systemSlotHotPlugIsPoweredOn(4) The system slot power (and corresponding LED) can be powered on. systemSlotHotPlugIsAtAttention(8) The system slot attention state (and corresponding LED) can be set. systemSlotHotPlugIsHotPluggable(2) The system slot supports hot-plug. systemSlotHotPlugIsPoweredOn(4) The system slot power (and corresponding LED) is on. systemSlotHotPlugIsAtAttention(8) The system slot attention state (and corresponding LED) is on. systemSlotHotPlugHasPowerFaulted (16) Power on fault (and corresponding LED) was detected due to a short or overcurrent. systemSlotHotPlugAdapterIsPresent Adapter (card) present in slot (32) (may not be powered). systemSlotHotPlugAdapterPresentAnd Adapter (card) present in slot PoweredOn(36) and powered. systemSlotHotPlugPowerButtonPressed The system slot power button (64) pressed to signal a toggle of the power state. systemSlotProvides5Volts(128) The system slot provides a 5-V supply. systemSlotProvides3Point3Volts(256) The system slot provides a 3.3-V supply. systemSlotIsShared(512) The slot’s opening is shared with another slot. Slot Group 357 Table 15-2. System Slot State Settings (continued) Variable Name: DellSystemSlotStateSettings Data Type: Integer Possible Data Values Meaning of Data Value systemSlotSupportsCard16(1024) The system slot supports PC Card-16. systemSlotSupportsCardBus(2048) The system slot supports CardBus. systemSlotSupportsZoomVideo(4096) The system slot supports zoom video. systemSlotSupportsModemRingResume The system slot supports modem (8192) ring resume. systemSlotSupportsPMESignal(16384) The system slot supports power management enable (PME#) signal. supportsPMEand3P3Vand5VandHotPlugg The system slot supports power able(16770) management enable. supportsPMEand3P3Vand5VhasAdapterO The system slot supports power n(16804) management event (PME), supplies 3.3 V, and supplies 5 V. The adapter is on. supportsPMEand3P3Vand5VhasAdapter The system slot supports PME, OnandisHotPluggable(16806) supplies 3.3 V, and supplies 5 V. The adapter is on and the system slot is hot pluggable. supportsPMEand3P3VIsSharedand5Vhas The system slot supports PME, AdapterOnandisHotPluggable(17316) supplies 3.3 V, supplies 5 V, and shares a slot opening. The adapter is on and the system slot is hot pluggable. 358 Slot Group Table 15-3. System Slot Type Variable Name: DellSystemSlotType Data Type: Integer Possible Data Values Meaning of Data Value systemSlotIsOther(1) The system slot type is not one of following: systemSlotIsUnknown(2) The system slot type is unknown. systemSlotIsISA(3) The system slot is Industry Standard Architecture (ISA). systemSlotIsMCA(4) The system slot is Micro Channel Architecture (MCA). systemSlotIsEISA(5) The system slot is Extended Industry Standard Architecture (EISA). systemSlotIsPCI(6) The system slot is Peripheral Component Interconnect (PCI). systemSlotIsPCMCIA(7) The system slot is compliant with the Personal Computer Memory Card International Association (PCMCIA) standards. systemSlotIsVLVESA(8) The system slot is Very Low Voltage Enterprise System Architecture (VLVESA). systemSlotIsProprietary(9) The system slot is proprietary. systemSlotIsProcessorCard(10) The system slot is a processor card. systemSlotIsProprietaryMemory(11) The system slot is proprietary memory. systemSlotIsIORiserCard(12) The system slot is an I/O riser card. systemSlotIsNuBUS(13) The system slot is a NuBus. systemSlotIsPCI66MHz(14) The system slot is a PCI66MHz. systemSlotIsAGP(15) The system slot is an Advanced Graphics Port (AGP). systemSlotIsAGP2X(16) The system slot is an AGP 2x card. systemSlotIsAGP4X(17) The system slot is an AGP 4x card. Slot Group 359 Table 15-3. System Slot Type (continued) Variable Name: DellSystemSlotType Data Type: Integer Possible Data Values Meaning of Data Value systemSlotIsPC98C20(18) The system slot is a PC-98/C20. systemSlotIsPC98C24(19) The system slot is a PC-98/C24. systemSlotIsPC98E(20) The system slot type is PC-98/E. systemSlotIsPC98LocalBus(21) The system slot type is a PC-98 local bus. systemSlotIsPC98Card(22) The system slot type is a PC-98 card. systemSlotIsPCIX(23) The system slot type is a PCIX card. systemSlotIsPCIExpress(24) The system slot type is a PCI Express card. systemSlotIsAGP8X(25) The system slot type is an AGP 8x card. systemSlotIsPCIExpressX1(166) The system slot type is a PCI Express x1. systemSlotIsPCIExpressX2(167) The system slot type is a PCI Express x2. systemSlotIsPCIExpressX4(168) The system slot type is a PCI Express x4. systemSlotIsPCIExpressX8(169) The system slot type is a PCI Express x8. systemSlotIsPCIExpressX16(170) The system slot type is a PCI Express x16. systemSlotIsPCIExpressGen2(171) The system slot type is PCI Express Gen 2. systemSlotIsPCIExpressGen2X1(172) The system slot type is PCI Express Gen 2 x1. systemSlotIsPCIExpressGen2X2(173) The system slot type is PCI Express Gen 2 x2. 360 Slot Group Table 15-3. System Slot Type (continued) Variable Name: DellSystemSlotType Data Type: Integer Possible Data Values Meaning of Data Value systemSlotIsPCIExpressGen2X4(174) The system slot type is PCI Express Gen 2 x4. systemSlotIsPCIExpressGen2X8(175) The system slot type is PCI Express Gen 2 x8. systemSlotIsPCIExpressGen2X16(176) The system slot type is PCI Express Gen 2 x16. Table 15-4. System Slot Usage Variable Name: DellSystemSlotUsage Data Type: Integer Possible Data Values Meaning of Data Value systemSlotUsageIsOther(1) The system slot usage is not one of following: systemSlotUsageIsUnknown(2) The system slot usage is unknown. systemSlotUsageIsAvailable(3) The system slot is available. systemSlotUsageIsInUse(4) Table 15-5. The system slot is in use. System Slot Length Variable Name: DellSystemSlotLength Data Type: Integer Possible Data Values Meaning of Data Value systemSlotLengthIsOther(1) The system slot length is not one of following: systemSlotLengthIsUnknown(2) The system slot length is unknown. systemSlotLengthIsShort(3) The system slot length is short. systemSlotLengthIsLong(4) The system slot length is long. Slot Group 361 Table 15-6. System Slot Category Variable Name: DellSystemSlotCategory Data Type: Integer Possible Data Values Meaning of Data Value systemSlotCategoryIsOther(1) The system slot category is not one of following: systemSlotCategoryIsUnknown(2) The system slot category is unknown. systemSlotCategoryIsBusConnector(3) The system slot is a bus connector. systemSlotCategoryIsPCMCIA(4) The system slot category is PCMCIA. systemSlotCategoryIsMotherboard(5) The system slot is a motherboard. Table 15-7. Hot-Plug Bus Width Variable Name: DellSystemSlotHotPlugBusWidth Data Type: Integer Possible Data Values Meaning of Data Value busWidthIsOther(1) The system slot bus width is not one of following: busWidthIsUnknown(2) The system slot bus width is unknown. busWidthIs8bits(3) The system slot bus width is 8 bits. busWidthIs16bits(4) The system slot bus width is 16 bits. busWidthIs32bits(5) The system slot bus width is 32 bits. busWidthIs64bits(6) The system slot bus width is 64 bits. busWidthIs128bits(7) The system slot bus width is 128 bits. busWidthIs1xOrx1(8) The system slot bus width is 1x or x1. busWidthIs2xOrx2(9) The system slot bus width is 2x or x2. busWidthIs4xOrx4(10) The system slot bus width is 4x or x4. busWidthIs8xOrx8(11) The system slot bus width is 8x or x8. 362 Slot Group Table 15-7. Hot-Plug Bus Width (continued) Variable Name: DellSystemSlotHotPlugBusWidth Data Type: Integer Possible Data Values Meaning of Data Value busWidthIs12xOrx12(12) The system slot bus width is 12x or x12. busWidthIs16xOrx16(13) The system slot bus width is 16x or x16. busWidthIs32xOrx32(14) The system slot bus width is 32x or x32. NOTE: System slot bus width of type n bits are for parallel buses such as PCI. NOTE: System slot bus width of type nx or xn are for serial buses such as PCI Express. Slot Group 363 364 Slot Group 16 16 Memory Group The Memory Group provides information about the physical memory in your system. Variables in this group include error correction type, location, and different types of memory use, such as cache, flash, system, video, and nonvolatile memory. Physical Memory Tables The following management information base (MIB) tables define the objects in the Memory Group: • "Physical Memory Array Table" on page 365 • "Physical Memory Array Mapped Table" on page 371 • "Physical Memory Configuration Table" on page 374 • "Physical Memory Logging Table" on page 377 • "Redundant Memory Unit Table" on page 379 • "Physical Memory Card Table" on page 382 Physical Memory Array Table The physical memory array is the entire physical memory of a system. The example that follows shows variable values for a system that has one 128-megabyte (MB) dual in-line memory module (DIMM): • physicalMemoryArrayMaximumSize = 2,097,152 kilobytes (KB) or 2 gigabytes (GB) • physicalMemoryArrayTotalNumberSockets = 4 (the example system has four DIMM slots on the motherboard) Memory Group 365 • 366 physicalMemoryArrayInUseNumberSockets = 1 (there is only one DIMM installed) Memory Group The following object sets up the Physical Memory Array Table: Name physicalMemoryArrayTable Object ID 1.3.6.1.4.1.674.10892.1.1300.10 Description Defines the Physical Memory Array Table. Syntax PhysicalMemoryArrayTableEntry Access Not accessible Physical Memory Array Table Entry Name physicalMemoryArrayTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1 Description Defines the Physical Memory Array Table entry. Syntax PhysicalMemoryArrayTableEntry Access Not accessible Index physicalMemoryArraychassisIndex, physicalMemoryArrayIndex Physical Memory Array Chassis Index Name physicalMemoryArraychassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Physical Memory Array Index Name physicalMemoryArrayIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.2 Description Defines the index (one-based) of the physical memory array in this chassis. Syntax DellObjectRange Access Read-only Memory Group 367 Physical Memory Array State Capabilities Name physicalMemoryArrayStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.3 Description Defines the capabilities of the physical memory array. Syntax DellStateCapabilities Access Read-only Physical Memory Array State Settings Name physicalMemoryArrayStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.4 Description Defines the state of the physical memory array. Syntax DellStateSettings Access read-write Physical Memory Array Status Name physicalMemoryArrayStatus Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.5 Description Defines the status of the physical memory array. Syntax DellStatus Access Read-only Physical Memory Array Use Name physicalMemoryArrayUse Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.6 Description Defines the use of the physical memory array. Syntax DellPhysicalMemoryArrayUse (See Table 16-2) Access Read-only 368 Memory Group Physical Memory Array Error Checking and Correcting (ECC) Type Name physicalMemoryArrayECCType Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.7 Description Defines the ECC type used by the physical memory array. Syntax DellPhysicalMemoryArrayECCType (See Table 16-2) Access Read-only Physical Memory Array Location Name physicalMemoryArrayLocation Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.8 Description Defines the location of the physical memory array. Syntax DellPhysicalMemoryArrayLocation (See Table 16-1) Access Read-only Physical Memory Array Maximum Size Name physicalMemoryArrayMaximumSize Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.9 Description Defines the size in KB of the physical memory array. Syntax DellUnsigned32BitRange Access Read-only Physical Memory Array Total Number Sockets Name physicalMemoryArrayTotalNumberSockets Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.10 Description Defines the total number of memory sockets available for the physical memory array. Syntax DellUnsigned32BitRange Access Read-only Memory Group 369 Physical Memory Array In Use Number Sockets Name physicalMemoryArrayInUseNumberSockets Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.11 Description Defines the total number of memory sockets in use by the physical memory array. Syntax DellUnsigned32BitRange Access Read-only Physical Memory Array ECC Error Nonrecoverable Threshold Name physicalMemoryArrayECCErrorNonRecoverbeThreshold Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.12 Description Defines the value of the physical memory array Error Checking and Correction (ECC) error nonrecoverable threshold. Syntax DellSigned32BitRange Access Read-only Physical Memory Array ECC Error Critical Threshold Name physicalMemoryArrayECCErrorCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.13 Description Defines the value of the physical memory array ECC error critical threshold. Syntax DellSigned32BitRange Access Read-only Physical Memory Array ECC Error Noncritical Threshold Name physicalMemoryArrayECCErrorNonCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.14 Description Defines the value of the physical memory array ECC error noncritical threshold. Syntax DellSigned32BitRange Access read-write 370 Memory Group Physical Memory Array Redundant Memory Unit Index Reference Name physicalMemoryArrayRedundantMemoryUnitIndex Reference Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.15 Description Defines the index to the associated Redundant Memory Unit in this chassis. Syntax DellObjectRange Access Read-only Physical Memory Array Mapped Table The physical memory array is divided into memory array mapped addresses. The following object sets up the Physical Memory Array Mapped Table: Name physicalMemoryArrayMappedTable Object ID 1.3.6.1.4.1.674.10892.1.1300.20 Description Defines the Physical Memory Array Mapped Table. Syntax PhysicalMemoryArrayMappedTableEntry Access Not accessible Physical Memory Array Mapped Table Entry Name PhysicalMemoryArrayMappedTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1300.20.1 Description Defines the Physical Memory Array Mapped Table entry. Syntax PhysicalMemoryArrayMappedTableEntry Access Not accessible Index physicalMemoryArrayMappedchassisIndex, physicalMemoryArrayMappedIndex Memory Group 371 Physical Memory Array Mapped Chassis Index Name physicalMemoryArrayMappedchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.20.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Physical Memory Array Mapped Index Name physicalMemoryArrayMappedIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.20.1.2 Description Defines the index (one-based) of the memory array mapped address in this chassis. Syntax DellObjectRange Access Read-only Physical Memory Array Mapped State Capabilities Name physicalMemoryArrayMappedStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1300.20.1.3 Description Defines the capabilities of the memory array mapped address. Syntax DellStateCapabilities Access Read-only Physical Memory Array Mapped State Settings Name physicalMemoryArrayMappedStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1300.20.1.4 Description Defines the state of the memory array mapped address. Syntax DellStateSettings Access Read-write 372 Memory Group Physical Memory Array Mapped Status Name physicalMemoryArrayMappedStatus Object ID 1.3.6.1.4.1.674.10892.1.1300.20.1.5 Description Defines the status of the memory array mapped address. Syntax DellStatus Access Read-only Physical Memory Array Index Reference Name physicalMemoryArrayIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1300.20.1.6 Description Defines the index to the associated physical memory array in this chassis. Syntax DellObjectRange Access Read-only Physical Memory Array Mapped Starting Address Name physicalMemoryArrayMappedStartingAddress Object ID 1.3.6.1.4.1.674.10892.1.1300.20.1.7 Description Defines the physical starting address in KB of the memory array mapped address. Syntax DellUnsigned64BitRange Access Read-only Physical Memory Array Mapped Ending Address Name physicalMemoryArrayMappedEndingAddress Object ID 1.3.6.1.4.1.674.10892.1.1300.20.1.8 Description Defines the physical ending address in KB of the memory array mapped address. Syntax DellUnsigned64BitRange Access Read-only Memory Group 373 Physical Memory Array Mapped Partition Width Name physicalMemoryArrayMappedPartitionWidth Object ID 1.3.6.1.4.1.674.10892.1.1300.20.1.9 Description Defines the number of memory devices that form a single row in the memory array mapped address. A zero (0) indicates that the number is unknown. Syntax DellUnsigned32BitRange Access Read-only Physical Memory Configuration Table This table defines how the physical memory of a system chassis is set up, for example, which redundant memory types are supported and whether redundant memory is active. The following object sets up the Physical Memory Configuration Table: Name physicalMemoryConfigTable Object ID 1.3.6.1.4.1.674.10892.1.1300.30 Description Defines the Physical Memory Configuration Table. Syntax SEQUENCE OF PhysicalMemoryConfigTableEntry Access Not accessible Physical Memory Configuration Table Entry Name physicalMemoryConfigTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1 Description Defines the Physical Memory Configuration Table entry. Syntax PhysicalMemoryConfigTableEntry Access Not accessible Index physicalMemoryConfigChassisIndex, physicalMemoryConfigIndex 374 Memory Group Physical Memory Configuration Chassis Index Name physicalMemoryConfigChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1.1 Description Defines the index (one-based) of the chassis associated with the physical memory configuration. Syntax DellObjectRange Access Read-only Physical Memory Configuration Index Name physicalMemoryConfigIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1.2 Description Defines the index (one-based) of the physical memory configuration. Syntax DellObjectRange Access Read-only Physical Memory Configuration State Capabilities Name physicalMemoryConfigStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1.3 Description Defines the state capabilities of the physical memory configuration. Syntax DellPhysicalMemoryConfigStateCapabilities Access Read-only Physical Memory Configuration State Settings Name physicalMemoryConfigStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1.4 Description Defines the state settings of the physical memory configuration. Syntax DellPhysicalMemoryConfigStateSettings Access Read-write Memory Group 375 Physical Memory Configuration Status Name physicalMemoryConfigStatus Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1.5 Description Defines the status of the physical memory configuration. Syntax DellStatus Access Read-only Physical Memory Configuration Redundant Capabilities Name physicalMemoryConfigRedundantCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1.6 Description Defines the redundant capabilities of the physical memory. Syntax DellPhysicalMemoryConfigRedundantCapabilities Access Read-only Physical Memory Configuration Redundant Settings Name physicalMemoryConfigRedundantSettings Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1.7 Description Defines the redundant settings of the physical memory. Syntax DellPhysicalMemoryConfigRedundantSettings Access Read-write Physical Memory Configuration MOM Capabilities Name physicalMemoryConfigMOMCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1.8 Description Defines the Memory Operating Mode capabilities of the physical memory. Syntax DellPhysicalMemoryConfigMOMCapabilities Access Read-only 376 Memory Group Physical Memory Configuration MOM Settings Name physicalMemoryConfigMOMSettings Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1.9 Description Defines the Memory Operating Mode settings of the physical memory. Syntax DellPhysicalMemoryConfigMOMSettings Access Read-only Physical Memory Logging Table This table defines the conditions for logging system memory events. The following object sets up the Physical Memory Logging Table: Name physicalMemoryLoggingTable Object ID 1.3.6.1.4.1.674.10892.1.1300.40 Description Defines the Physical Memory Logging Table. Syntax SEQUENCE OF PhysicalMemoryLoggingTableEntry Access Not accessible Physical Memory Logging Table Entry Name physicalMemoryLoggingTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1300.40.1 Description Defines the Physical Memory Logging Table entry. Syntax PhysicalMemoryLoggingTableEntry Access Not accessible Index physicalMemoryLoggingChassisIndex, physicalMemoryLoggingIndex Memory Group 377 Physical Memory Logging Chassis Index Name physicalMemoryLoggingChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.40.1.1 Description Defines the index (one-based) of the chassis associated with the physical memory logging. Syntax DellObjectRange Access Read-only Physical Memory Logging Index Name physicalMemoryLoggingIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.40.1.2 Description Defines the index (one-based) of the physical memory logging. Syntax DellObjectRange Access Read-only Physical Memory Logging Capabilities Name physicalMemoryLoggingCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1300.40.1.3 Description Defines the capabilities of the physical memory logging. Syntax DellPhysicalMemoryLoggingCapabilities Access Read-only Physical Memory Logging Settings Name physicalMemoryLoggingSettings Object ID 1.3.6.1.4.1.674.10892.1.1300.40.1.4 Description Defines the settings of the physical memory logging. Syntax DellPhysicalMemoryLoggingSettings Access Read-write 378 Memory Group Physical Memory Logging Status Name physicalMemoryLoggingStatus Object ID 1.3.6.1.4.1.674.10892.1.1300.40.1.5 Description Defines the status of the physical memory logging. Syntax DellStatus Access Read-only Redundant Memory Unit Table This table reports the status of redundant memory within a particular system chassis. The following object sets up the Redundant Memory Unit Table: Name redundantMemoryUnitTable Object ID 1.3.6.1.4.1.674.10892.1.1300.50 Description Defines the Redundant Memory Unit Table. Syntax SEQUENCE OF RedundantMemoryUnitTableEntry Access Not accessible Memory Group 379 Redundant Memory Unit Table Entry Name redundantMemoryUnitTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1300.50.1 Description Defines the Redundant Memory Unit Table entry. Syntax RedundantMemoryUnitTableEntry Access Not accessible Index redundantMemoryUnitChassisIndex, redundantMemoryUnitIndex Redundant Memory Unit Chassis Index Name redundantMemoryUnitChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.50.1.1 Description Defines the index (one-based) of the chassis associated with the redundant memory unit. Syntax DellObjectRange Access Read-only Redundant Memory Unit Index Name redundantMemoryUnitIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.50.1.2 Description Defines the index (one-based) of the redundant memory unit. Syntax DellObjectRange Access Read-only Redundant Memory Unit State Capabilities Name redundantMemoryUnitStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1300.50.1.3 Description Defines the state capabilities of the redundant memory unit. Syntax DellStateCapabilities Access Read-only 380 Memory Group Redundant Memory Unit State Settings Name redundantMemoryUnitStatesettings Object ID 1.3.6.1.4.1.674.10892.1.1300.50.1.4 Description Defines the state settings of the redundant memory unit. Syntax DellStateSettings Access Read-write Redundant Memory Unit Redundancy Status Name redundantMemoryUnitRedundancyStatus Object ID 1.3.6.1.4.1.674.10892.1.1300.50.1.5 Description Defines the redundancy status of the redundant memory unit. Syntax DellStatusRedundancy Access Read-only Redundant Memory Unit Name Name redundantMemoryUnitName Object ID 1.3.6.1.4.1.674.10892.1.1300.50.1.6 Description Defines the name of the redundant memory unit. Syntax DellString Access Read-only Redundant Memory Unit Status Name redundantMemoryUnitStatus Object ID 1.3.6.1.4.1.674.10892.1.1300.50.1.7 Description Defines the status of the redundant memory unit. Syntax DellStatus Access Read-only Memory Group 381 Physical Memory Card Table This table defines the name of the memory card, the total number of device slots present on the memory card, and the number of memory device slots in use on the memory card. The following objects set up the Physical Memory Card Table: Physical Memory Card Table Name physicalMemoryCardTable Object ID 1.3.6.1.4.1.674.10892.1.1300.60 Description Defines the Physical Memory Card Table. Syntax SEQUENCE OF PhysicalMemoryCardTableEntry Access Not accessible Physical Memory Card Table Entry Name physicalMemoryCardTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1300.60.1 Description Defines the Physical Memory Card Table Entry. Syntax PhysicalMemoryCardTableEntry Access Not accessible Index physicalMemoryCardChassisIndex, physicalMemoryCardIndex Physical Memory Card Chassis Index Name physicalMemoryCardChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.60.1.1 Description Defines the index (one-based) of the associated chassis. Syntax DellObjectRange Access Read-only 382 Memory Group Physical Memory Card Index Name physicalMemoryCardIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.60.1.2 Description Defines the index (one-based) of the Physical Memory Card. Syntax DellObjectRange Access Read-only Physical Memory Card State Capabilities Name physicalMemoryCardStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1300.60.1.3 Description Defines the state capabilities of the Physical Memory Card. Syntax DellStateCapabilities Access Read-only Physical Memory Card State Settings Name physicalMemoryCardStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1300.60.1.4 Description Defines the state settings of the Physical Memory Card. Syntax DellStateSettings Access Read-write Physical Memory Card Status Name physicalMemoryCardStatus Object ID 1.3.6.1.4.1.674.10892.1.1300.60.1.5 Description Defines the status of the Physical Memory Card. Syntax DellStatus Access Read-only Memory Group 383 Physical Memory Card Name Name physicalMemoryCardName Object ID 1.3.6.1.4.1.674.10892.1.1300.60.1.6 Description Defines the name of the Physical Memory Card. Syntax DellString Access Read-only Physical Memory Card Total Number Sockets Name physicalMemoryCardTotalNumberSockets Object ID 1.3.6.1.4.1.674.10892.1.1300.60.1.7 Description Defines the total number of memory sockets available on the Physical Memory Card. 2,147,483,647 indicates an unknown number of sockets. Syntax DellUnsigned32BitRange Access Read-only Physical Memory Card In Use Number Sockets Name physicalMemoryCardInUseNumberSockets Object ID 1.3.6.1.4.1.674.10892.1.1300.60.1.8 Description Defines the number of memory sockets in use on the Physical Memory Card. Zero indicates that the Physical Memory Card is not installed or has a configuration error. Syntax DellUnsigned32BitRange Access Read-only 384 Memory Group Physical Memory Card Physical Memory Array Index Reference Name physicalMemoryCardPhyMemArrayIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1300.60.1.9 Description Defines the index (one-based) of the Physical Memory Array Table entry for the physical memory array with the same chassis index that this physical memory card is associated with. Syntax DellObjectRange Access Read-only Memory Group Variable Values This section includes definitions for server administrator-specific variable values used in this section. Table 16-1. Physical Memory Array Location Variable Name: DellPhysicalMemoryArrayLocation Data Type: Integer Possible Data Values Meaning of Data Value memoryArrayLocationIsOther(1) The memory array location is not one of the following: memoryArrayUseIsUnknown(2) The memory array use is unknown. memoryArrayUseIsSystemMemory(3) The memory array is system memory. memoryArrayUseIsVideoMemory(4) The memory array is video memory. memoryArrayUseIsFLASHMemory(5) The memory array is FLASH memory. memoryArrayUseIsNonVolatileRAMMemory(6) The memory array is nonvolatile RAM. memoryArrayUseIsCacheMemory(7) The memory array is cache memory. Memory Group 385 Table 16-1. Physical Memory Array Location (continued) Variable Name: DellPhysicalMemoryArrayLocation Data Type: Integer Possible Data Values Meaning of Data Value memoryArrayLocationIsPCMCIA(8) The memory array location is a Personal Computer Memory Card International Association (PCMCIA) option card. memoryArrayLocationIsProprietary(9) The memory array location is a proprietary option card. memoryArrayLocationIsNUBUS(10) The memory array location is a NuBus bus. memoryArrayLocationIsPC98C20(11) The memory array location is a PC-98/C20 option card. memoryArrayLocationIsPC98C24(12) The memory array location is a PC-98/C24 option card. memoryArrayLocationIsPC98E(13) The memory array location is a PC-98/E option card. memoryArrayLocationIsPC98LocalBus(14) The memory array location is a PC-98/Local bus option card. memoryArrayLocationIsPC98Card(15) The memory array location is a PC-98/Card slot option card. 386 Memory Group Table 16-2. Physical Memory Array ECC Type Definitions Variable Name: DellPhysicalMemoryArrayECCType Data Type: Integer Possible Data Values Meaning of Data Value memoryArrayECCTypeIsOther(1) There is not one of the following: memoryArrayECCTypeIsUnknown(2) The memory array ECC type is unknown. memoryArrayECCTypeIsNone(3) The memory array ECC type is none. memoryArrayECCTypeIsParity(4) The memory array ECC type is parity. memoryArrayECCTypeIsSingleBitECC(5) The memory array ECC type is Correctable Memory Event ECC. memoryArrayECCTypeIsMultiBitECC(6) The memory array ECC type is Uncorrectable Memory Event ECC. memoryArrayECCTypeIsCRC(7) The memory array ECC type is CRC. Table 16-3. Physical Memory Configuration State Capabilities Variable Name: DellPhysicalMemoryConfigStateCapabilities Data Type: Integer Possible Data Values Meaning of Data Value If set to 0 (zero) There are no state capabilities. unknownCapabilities(1) State capabilities are unknown. enableCapable(2) Object enable/disable is supported. notReadyCapable(4) Object not ready is supported. Memory Group 387 Table 16-4. Physical Memory Configuration State Settings Variable Name: DellPhysicalMemoryConfigStateSettings Data Type: Integer Possible Data Values Meaning of Data Value If set to 0 (zero) There are no state settings. unknown(1) State settings are unknown. enabled(2) Object is disabled (offline) 0, or enabled (online) 1. notReady(4) Object not ready. redundantMemoryIsActive(8) Redundant memory is active (in use) enabledAndRedundantMemoryIsActive(10) Redundant memory is enabled and in use. Table 16-5. Physical Memory Configuration Redundant Capabilities Variable Name: DellPhysicalMemoryConfigRedundantCapabilities Data Type: Integer Possible Data Values Meaning of Data Value If set to 0 (zero) There are no redundant memory capabilities. unknownCapabilities(1) Redundant capabilities are unknown. The redundant capabilities are: spareCapable(2) Spare redundant memory feature is supported. mirrorCapable(4) Mirror redundant memory feature is supported. spareAndMirrorCapable(6) Spare and mirror redundant memory features are supported. raidCapable(8) Redundant Array of Independent disks (RAID) redundant memory feature is supported. dddcCapable(16) DDDC redundancy is supported. 388 Memory Group Table 16-6. Physical Memory Configuration Redundant Settings Variable Name: DellPhysicalMemoryConfigRedundantSettings Data Type: Integer Possible Data Values Meaning of Data Value If set to 0 (zero) There are no redundant memory settings enabled. unknown(1) Redundant settings are unknown. The following redundant settings are mutually exclusive: spareEnabled(2) Spare redundant memory feature is enabled. mirrorEnabled(4) Mirror redundant memory feature is enabled. raidEnabled(8) RAID redundant memory feature is enabled. dddcCapable(16) DDDC redundancy is enabled. Table 16-7. Physical Memory Logging Capabilities Variable Name: DellPhysicalMemoryLoggingCapabilities Data Type: Integer Possible Data Values Meaning of Data Value If set to 0 (zero) There are no logging capabilities. unknown Capabilities(1) Logging capabilities are unknown. The logging capabilities are: enableCapable(2) Logging enable/disable using Simple Network Management Protocol (SNMP) is supported. Memory Group 389 Table 16-8. Physical Memory Logging Settings Variable Name: DellPhysicalMemoryLoggingSettings Data Type: Integer Possible Data Values Meaning of Data Value If set to 0 (zero) There are no logging settings enabled. unknown Capabilities(1) Logging capabilities are unknown. The logging settings are: enabled(2) 390 Memory Group Logging is disabled (0), or enabled (1). BIOS Setup Control Group 17 Basic Input/Output System (BIOS) Setup Control Group variables provide information about the functions that the BIOS performs in your system. This management information base (MIB) group includes variables for the boot sequence, speakers, diskettes, ports, network interface controllers (NICs), and the Wakeup on local area network (LAN) feature. BIOS Setup Control Group Tables The MIB tables in this group define the BIOS control of devices and controller cards that are typically present in a system. • "BIOS Setup Control Table" on page 391 • "SCSI Control Table" on page 402 • "Parallel Port Control Table" on page 404 • "Serial Port Control Table" on page 406 • "USB Control Table" on page 408 • "IDE Control Table" on page 410 • "Diskette Control Table" on page 412 • "Network Interface Control Table" on page 414 The following MIB table in the BIOS Setup Control Group is supported on Dell PowerEdge xx2x (12G) systems: • "BIOS Setting Table" on page 417 BIOS Setup Control Table Name biosSetUpControlTable Object ID 1.3.6.1.4.1.674.10892.1.1400.10 Description Defines the set of single devices in a chassis controlled by the BIOS. Syntax BiosSetUpControlTableEntry BIOS Setup Control Group 391 Name biosSetUpControlTable Access Not accessible BIOS Setup Control Table Entry Name biosSetUpControlTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1 Description Defines the BIOS Control Device Table entry. Syntax BiosSetUpControlTableEntry Access Not accessible Index biosSetUpControlchassisIndex BIOS Setup Control Chassis Index Name biosSetUpControlchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only BIOS Setup Control (BSUC) Pointing Device Control Capabilities Name bSUCpointingDeviceControlCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.2 Description Defines the capabilities of the pointing device. Syntax DellStateCapabilities Access Read-only BIOS Setup Control Pointing Device Control Settings Name bSUCpointingDeviceControlSettings Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.3 Description Defines the state of the pointing device. 392 BIOS Setup Control Group Name bSUCpointingDeviceControlSettings Syntax DellStateSettings Access Read-write BIOS Setup Control Pointing Device Control Status Name bSUCpointingDeviceControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.4 Description Defines the status of the pointing device. Syntax DellStatus Access Read-only BIOS Setup Control Pointing Device Control Name Name bSUCpointingDeviceControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.5 Description Defines the setup BIOS name of the pointing device. Syntax DellString Access Read-only BIOS Setup Control Numeric Lock Control Capabilities Name bSUCnumLockControlCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.6 Description Defines the capabilities of the numeric lock. Syntax DellStateCapabilities Access Read-only BIOS Setup Control Numeric Lock Control Settings Name bSUCnumLockControlSettings Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.7 Description Defines the state of the numeric lock. BIOS Setup Control Group 393 Name bSUCnumLockControlSettings Syntax DellStateSettings Access Read-only BIOS Setup Control Numeric Lock Control Status Name bSUCnumLockControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.8 Description Defines the status of the numeric lock. Syntax DellStatus Access Read-only BIOS Setup Control Numeric Lock Control Name Name bSUCnumLockControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.9 Description Defines the setup BIOS name of the numeric lock. Syntax DellString Access Read-only BIOS Setup Control Processor Serial Number Control Capabilities Name bSUCprocessorSerialNumberControlCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.10 Description Defines if the processor serial number can be returned. Syntax DellStateCapabilities Access Read-only BIOS Setup Control Processor Serial Number Control Settings Name bSUCprocessorSerialNumberControlSettings Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.11 Description Defines the state of the processor serial number. 394 BIOS Setup Control Group Name bSUCprocessorSerialNumberControlSettings Syntax DellStateSettings Access Read-only BIOS Setup Control Processor Serial Number Control Status Name bSUCprocessorSerialNumberControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.12 Description Defines the status of the processor serial number. Syntax DellStatus Access Read-only BIOS Setup Control Processor Serial Number Control Name Name bSUCprocessorSerialNumberControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.13 Description Defines the setup BIOS name of the processor serial number. Syntax DellString Access Read-write BIOS Setup Control Speaker Control Capabilities Unique Name bSUCspeakerControlCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.14 Description Defines the capabilities of the speaker control. Syntax DellSpeakerControlCapabilitiesUnique (See Table 17-1) Access Read-only BIOS Setup Control Speaker Control Settings Unique Name bSUCspeakerControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.15 Description Defines the settings available for speaker control. BIOS Setup Control Group 395 Name bSUCspeakerControlSettingsUnique Syntax DellSpeakerControlSettingsUnique (See Table 17-2) Access Read-only BIOS Setup Control Speaker Control Status Name bSUCspeakerControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.16 Description Defines the status of speaker control. Syntax DellStatus Access Read-only BIOS Setup Control Speaker Control Name Name bSUCspeakerControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.17 Description Defines the setup BIOS name of the speaker control. Syntax DellString Access Read-only BIOS Setup Control NIF Wakeup on LAN Control Capabilities Unique Name bSUCnIFwakeonLanControlCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.18 Description Defines the defines the capabilities of the network interface function (NIF) Wakeup on LAN. Syntax DellNIFwakeonLanControlCapabilitiesUnique (See Table 17-4) Access Read-only BIOS Setup Control NIF Wakeup on LAN Control Settings Unique Name bSUCnIFwakeonLanControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.19 396 BIOS Setup Control Group Name bSUCnIFwakeonLanControlSettingsUnique Description Defines the state of the NIF Wakeup on LAN. Syntax DellNIFwakeonLanControlSettingsUnique (See Table 17-4) Access Read-only BIOS Setup Control NIF Wakeup on LAN Control Status Name bSUCnIFwakeonLanControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.20 Description Defines the status of the NIF Wakeup on LAN. Syntax DellStatus Access Read-only BIOS Setup Control NIF Wakeup on LAN Control Name Name bSUCnIFwakeonLanControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.21 Description Defines the setup BIOS name of the NIF Wakeup on LAN. Syntax DellString Access Read-only BIOS Setup Control Boot Sequence Control Capabilities Unique Name bSUCbootSequenceControlCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.22 Description Defines the capabilities of the boot sequence. Syntax DellBootSequenceControlCapabilitiesUnique (See Table 17-5) Access Read-only BIOS Setup Control Boot Sequence Control Settings Unique Name DellBootSequenceControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.23 BIOS Setup Control Group 397 Name DellBootSequenceControlSettingsUnique Description Defines the state of the boot sequence. Syntax DellBootSequenceControlSettingsUnique (See Table 17-6) Access Read-only BIOS Setup Control Boot Sequence Control Status Name bSUCbootSequenceControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.24 Description Defines the status of the boot sequence. Syntax DellStatus Access Read-only BIOS Setup Control Boot Sequence Control Name Name bSUCbootSequenceControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.25 Description Defines the control name of the boot sequence. Syntax DellString Access Read-only BIOS Setup Control Administrator Password Control Capabilities Unique Name bSUCadministratorPasswordControlCapabilities Unique Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.26 Description Defines the capabilities of the administrator password control. Syntax DellBIOSPasswordControlCapabilitiesUnique Access Read-only 398 BIOS Setup Control Group BIOS Setup Control Administrator Password Control Settings Unique Name bSUCadministratorPasswordControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.27 Description Defines the settings for administrator password control. Syntax DellBIOSPasswordControlSettingsUnique (See Table 17-9) Access Read-write BIOS Setup Control Administrator Password Control Status Name bSUCadministratorPasswordControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.28 Description Defines the status for administrator password control. Syntax DellStatus Access Read-only BIOS Setup Control Administrator Password Verify Name Name bSUCadministratorPasswordVerifyName Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.29 Description Defines the setup BIOS name for the current administrator password. Syntax DellString Access Read-write BIOS Setup Control Administrator Password New Password Name Name bSUCadministratorPasswordNewPasswordName Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.30 Description Defines the setup BIOS name of the new administrator password. To set a new administrator password, you must have successfully set the current administrator password immediately preceding this password change. Syntax DellString Access Read-write BIOS Setup Control Group 399 BIOS Setup Control User Password Control Capabilities Unique Name bSUCuserPasswordControlCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.31 Description Defines the capabilities of user password control. Syntax DellBIOSPasswordControlCapabilitiesUnique Access Read-only BIOS Setup Control User Password Control Settings Unique Name bSUCuserPasswordControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.32 Description Defines the control settings for user password control. Syntax DellBIOSPasswordControlSettingsUnique (See Table 17-9) Access Read-write BIOS Setup Control User Password Control Status Name bSUCuserPasswordControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.33 Description Defines the status of the user password control. Syntax DellStatus Access Read-only BIOS Setup Control User Password Verify Name Name bSUCuserPasswordVerifyName Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.34 Description Defines the setup BIOS name of the current user password. Syntax DellString Access Read-write 400 BIOS Setup Control Group BIOS Setup Control User Password New Password Name Name bSUCuserPasswordNewPasswordName Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.35 Description Defines the setup BIOS name of the new user password. To set a new user password, a you must have successfully set the current user password immediately preceding this password change. Syntax DellString Access Read-write BIOS Setup Control TPM Security Control Capabilities Name bSUCtpmSecurityControlCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.36 Description Defines the BIOS setup control capabilities of Trusted Platform Module (TPM) security. Syntax DellTPMSecurityControlCapabilities Access Read-only BIOS Setup Control TPM Security Control Setting Name bSUCtpmSecurityControlSetting Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.37 Description Defines the BIOS setup control setting of Trusted Platform Module (TPM) security. Syntax DellTPMSecurityControlSetting Access Read-only BIOS Setup Control TPM Security Control Status Name bSUCtpmSecurityControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.38 Description Defines the BIOS setup control status of Trusted Platform Module (TPM) security. Syntax DellStatus Access Read-only BIOS Setup Control Group 401 BIOS Setup Control TPM Security Control Name Name bSUCtpmSecurityControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.39 Description Defines the BIOS setup control name of Trusted Platform Module (TPM) security. Syntax DellString Access Read-only SCSI Control Table Name sCSIControlTable Object ID 1.3.6.1.4.1.674.10892.1.1400.20 Description Defines the Small Computer System Interface (SCSI) Control Table. Syntax SCSIControlTableEntry Access Not accessible SCSI Control Table Entry Name sCSIControlTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1400.20.1 Description Defines the SCSI Control Table entry. Syntax SCSIControlTableEntry Access Not accessible Index sCSIControlchassisIndex, sCSIControlIndex SCSI Control Chassis Index Name sCSIControlchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.20.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only 402 BIOS Setup Control Group SCSI Control Index Name sCSIControlIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.20.1.2 Description Defines the index (one-based) of the SCSI controller in this chassis. Syntax DellObjectRange Access Read-only SCSI Control Capabilities Name sCSIControlCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1400.20.1.3 Description Defines the capabilities of the SCSI controller. Syntax DellStateCapabilities Access Read-only SCSI Control Settings Name sCSIControlSettings Object ID 1.3.6.1.4.1.674.10892.1.1400.20.1.4 Description Defines the state of the SCSI controller. Syntax DellStateSettings Access Read-only SCSI Control Status Name sCSIControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.20.1.5 Description Defines the status of the SCSI controller. Syntax DellStatus Access Read-only BIOS Setup Control Group 403 SCSI Control Name Name sCSIControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.20.1.6 Description Defines the setup BIOS name of the SCSI controller. Syntax DellString Access Read-only Parallel Port Control Table Name parallelPortControlTable Object ID 1.3.6.1.4.1.674.10892.1.1400.30 Description Defines the Parallel Port Control Table. Syntax ParallelPortControlTableEntry Access Not accessible Parallel Port Control Table Entry Name parallelPortControlTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1400.30.1 Description Defines the Parallel Port Control Table entry. Syntax ParallelPortControlTableEntry Access Not accessible Index parallelPortControlchassisIndex, parallelPortControlIndex Parallel Port Control Chassis Index Name parallelPortControlchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.30.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only 404 BIOS Setup Control Group Parallel Port Control Index Name parallelPortControlIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.30.1.2 Description Defines the index (one-based) of the parallel port in this chassis. Syntax DellObjectRange Access Read-only Parallel Port Control Capabilities Unique Name parallelPortControlCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.30.1.3 Description Defines the capabilities of the parallel port. Syntax DellParallelPortControlCapabilitiesUnique (See Table 17-12) Access Read-only Parallel Port Control Settings Unique Name parallelPortControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.30.1.4 Description Defines the state of the parallel port. Syntax DellParallelPortControlSettingsUnique (See Table 17-13) Access Read-only Parallel Port Control Status Name parallelPortControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.30.1.5 Description Defines the status of the parallel port. Syntax DellStatus Access Read-only BIOS Setup Control Group 405 Parallel Port Control Name Name parallelPortControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.30.1.6 Description Defines the setup BIOS name of the parallel port. Syntax DellString Access Read-only Parallel Port Control Mode Capabilities Unique Name parallelPortControlModeCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.30.1.7 Description Defines the mode capabilities of the parallel port. Syntax DellParallelPortControlModeCapabilitiesUnique (See Table 17-14) Access Read-only Parallel Port Control Mode Settings Unique Name parallelPortControlModeSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.30.1.8 Description Defines the mode settings of the parallel port. Syntax DellParallelPortControlModeSettingsUnique (See Table 17-14) Access Read-write Serial Port Control Table Name serialPortControlTable Object ID 1.3.6.1.4.1.674.10892.1.1400.40 Description Defines the Serial Port Control Table. Syntax SerialPortControlTableEntry Access Not accessible 406 BIOS Setup Control Group Serial Port Control Table Entry Name serialPortControlTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1400.40.1 Description Defines the Serial Port Control Table entry. Syntax SerialPortControlTableEntry Access Not accessible Index serialPortControlchassisIndex, serialPortControlIndex Serial Port Control Chassis Index Name serialPortControlchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.40.1.1 Description Defines index (one-based) of this chassis. Syntax DellObjectRange Access read-only Serial Port Control Index Name serialPortControlIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.40.1.2 Description Defines the index (one-based) of the serial port in this chassis. Syntax DellObjectRange Access read-only Serial Port Control Capabilities Unique Name serialPortControlCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.40.1.3 Description Defines the capabilities of the serial port. Syntax DellSerialPortControlCapabilitiesUnique (See Table 17-15) Access Read-only BIOS Setup Control Group 407 Serial Port Control Settings Unique Name serialPortControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.40.1.4 Description Defines the settings of the serial port. Syntax DellSerialPortControlSettingsUnique (See Table 17-16) Access Read-only Serial Port Control Status Name serialPortControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.40.1.5 Description Defines the status of the serial port. Syntax DellStatus Access Read-only Serial Port Control Name Name serialPortControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.40.1.6 Description Defines the setup BIOS name of the serial port. Syntax DellString Access Read-only USB Control Table These objects enable you to track the attributes of your Universal Serial Bus (USB). Name usbControlTable Object ID 1.3.6.1.4.1.674.10892.1.1400.50 Description Defines the USB Table. Syntax UsbControlTableEntry Access Not accessible 408 BIOS Setup Control Group USB Control Table Entry Name usbControlTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1400.50.1 Description Defines the USB Table entry. Syntax UsbControlTableEntry Access Not accessible Index usbControlchassisIndex, usbControlIndex USB Control Chassis Index Name usbControlchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.50.1.1 Description Defines index (one-based) of this chassis. Syntax DellObjectRange Access Read-only USB Control Index Name usbControlIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.50.1.2 Description Defines the index (one-based) of the USB in this chassis. Syntax DellObjectRange Access Read-only USB Control Capabilities Name usbControlCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1400.50.1.3 Description Defines the capabilities of the USB. Syntax DellStateCapabilities Access Read-only BIOS Setup Control Group 409 USB Control Settings Name usbControlSettings Object ID 1.3.6.1.4.1.674.10892.1.1400.50.1.4 Description Defines the control settings for the USB. Syntax DellStateSettings Access Read-only USB Control Status Name usbControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.50.1.5 Description Defines the status of the USB. Syntax DellStatus Access Read-only USB Control Name Name usbControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.50.1.6 Description Defines the setup BIOS name of the USB. Syntax DellString Access Read-only IDE Control Table These objects enable you to track the attributes of Integrated Device Electronics (IDE) controller cards in your system. Name ideControlTable Object ID 1.3.6.1.4.1.674.10892.1.1400.60 Description Defines the IDE Control Table. Syntax IdeControlTableEntry Access Not accessible 410 BIOS Setup Control Group IDE Control Table Entry Name ideControlTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1400.60.1 Description Defines the IDE Control Table entry. Syntax IdeControlTableEntry Access Not accessible Index ideControlchassisIndex, ideControlIndex IDE Control Chassis Index Name ideControlchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.60.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only IDE Control Index Name ideControlIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.60.1.2 Description Defines the index (one-based) of the IDE controller in this chassis. Syntax DellObjectRange Access Read-only IDE Control Capabilities Unique Name ideControlCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.60.1.3 Description Defines the capabilities of the IDE controller. Syntax DellideControlCapabilitiesUnique (See Table 17-17) Access Read-only BIOS Setup Control Group 411 IDE Control Settings Unique Name ideControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.60.1.4 Description Defines the settings for the IDE controller. Syntax DellideControlCapabilitiesUnique (See Table 17-17) Access Read-only IDE Control Status Name ideControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.60.1.5 Description Defines the status for the IDE controller. Syntax DellStatus Access Read-only IDE Control Name Name ideControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.60.1.6 Description Defines the setup BIOS name for the IDE controller. Syntax DellStatus Access Read-only Diskette Control Table Name disketteControlTable Object ID 1.3.6.1.4.1.674.10892.1.1400.70 Description Defines the Diskette Control Table. Syntax DisketteControlTableEntry Access Not accessible 412 BIOS Setup Control Group Diskette Control Table Entry Name disketteControlTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1400.70.1 Description Defines the Diskette Control Table entry. Syntax DellStatus Access Not accessible Index disketteControlchassisIndex, disketteControlIndex Diskette Control Chassis Index Name disketteControlchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.70.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Diskette Control Index Name disketteControlIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.70.1.2 Description Defines the index of the diskette controllers in this chassis. Syntax DellObjectRange Access Read-only Diskette Control Capabilities Unique Name disketteControlCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.70.1.3 Description Defines the capabilities of the diskette controller. Syntax DellDisketteControlCapabilitiesUnique (See Table 17-18) Access Read-only BIOS Setup Control Group 413 Diskette Control Settings Unique Name disketteControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.70.1.4 Description Defines the control settings for the diskette controller. Syntax DellDisketteControlSettingsUnique Access Read-only Diskette Control Status Name disketteControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.70.1.5 Description Defines the status of the diskette controller. Syntax DellStatus Access Read-only Diskette Control Name Name disketteControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.70.1.6 Description Defines the setup BIOS name of the diskette controller. Syntax DellString Access Read-only Network Interface Control Table These MIB objects enable you to track the attributes of the NIC card for your system. Name networkInterfaceControlTable Object ID 1.3.6.1.4.1.674.10892.1.1400.80 Description Defines the Network Interface Control Table. Syntax NetworkInterfaceControlTableEntry Access Not accessible 414 BIOS Setup Control Group Network Interface Control Table Entry Name networkInterfaceControlTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1400.80.1 Description Defines the Network Interface Control Table entry. Syntax NetworkInterfaceControlTableEntry Access Not accessible Index networkInterfaceControlchassisIndex, networkInterfaceControlIndex Network Interface Control Chassis Index Name networkInterfaceControlchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.80.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Network Interface Control Index Name networkInterfaceControlIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.80.1.2 Description Defines the index (one-based) of the network interface controller in this chassis. Syntax DellObjectRange Access Read-only BIOS Setup Control Group 415 Network Interface Control Capabilities Unique Name networkInterfaceControlCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.80.1.3 Description Defines the capabilities of the NIC. Syntax DellNetworkInterfaceControlCapabilitiesUnique (See Table 17-19) Access Read-only Network Interface Control Settings Unique Name networkInterfaceControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.80.1.4 Description Defines the control settings for the NIC. Syntax DellNetworkInterfaceControlSettingsUnique (See Table 17-20) Access Read-write Network Interface Control Status Name networkInterfaceControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.80.1.5 Description Defines the status of the NIC. Syntax DellStatus Access Read-only Network Interface Control Name Name networkInterfaceControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.80.1.6 Description Defines the setup BIOS name of the NIC. Syntax DellString Access Read-only 416 BIOS Setup Control Group BIOS Setting Table These MIB objects enable you to track the BIOS settings for your system. NOTE: These MIB objects are supported on Dell PowerEdge xx2x systems. Name biosSettingTable Object ID 1.3.6.1.4.1.674.10892.1.1400.90 Description Defines the BIOS Setting Table. Syntax SEQUENCE OF BiosSettingTableEntry Access Not accessible BIOS Setting Table Entry Name biosSettingTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1400.90.1 Description Defines the BIOS Setting Table Entry. Syntax BiosSettingTableEntry Access Not accessible Index biosSettingChassisIndex, biosSettingIndex BIOS Setting Chassis Index Name biosSettingChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.90.1.1 Description Defines the index (one based) of the associated chassis. Syntax DellObjectRange Access Read-only BIOS Setting Index Name biosSettingIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.90.1.2 BIOS Setup Control Group 417 Description Defines the index (one based) of the BIOS setting. Syntax DellObjectRange Access Read-only BIOS Setting Name Name biosSettingName Object ID 1.3.6.1.4.1.674.10892.1.1400.90.1.3 Description Defines the name of the BIOS setting. Syntax DisplayString Access Read-only BIOS Setting Display Name Name biosSettingDisplayName Object ID 1.3.6.1.4.1.674.10892.1.1400.90.1.4 Description Defines the display name of the BIOS setting. Syntax DisplayString Access Read-only BIOS Setting Value Type Name biosSettingValueType Object ID 1.3.6.1.4.1.674.10892.1.1400.90.1.5 Description Defines the type of the BIOS setting value. Syntax DellBIOSSettingValueType Access Read-only BIOS Setting Current Value Name biosSettingCurrentValue Object ID 1.3.6.1.4.1.674.10892.1.1400.90.1.6 Description Defines the current value of the BIOS setting. 418 BIOS Setup Control Group Syntax DisplayString Access Read-only BIOS Setting Pending Value Name biosSettingPendingValue Object ID 1.3.6.1.4.1.674.10892.1.1400.90.1.7 Description Defines the pending value of the BIOS setting. Syntax DisplayString Access Read-only BIOS Setting Default Value Name biosSettingDefaultValue Object ID 1.3.6.1.4.1.674.10892.1.1400.90.1.8 Description Defines the default value of the BIOS setting. Syntax DisplayString Access Read-only BIOS Setting Possible Values Name biosSettingPossibleValues Object ID 1.3.6.1.4.1.674.10892.1.1400.90.1.9 Description Defines the possible values of the BIOS setting. Syntax DisplayString Access Read-only BIOS Setting Display Order Name biosSettingDisplayOrder Object ID 1.3.6.1.4.1.674.10892.1.1400.90.1.10 Description Defines the recommended display order of the BIOS setting within its BIOS setting group. BIOS Setup Control Group 419 Syntax DellUnsigned32BitRange Access Read-only BIOS Setting Group Display Name Name biosSettingGroupDisplayName Object ID 1.3.6.1.4.1.674.10892.1.1400.90.1.11 Description Defines the display name of the BIOS setting group for the BIOS setting. Syntax DisplayString Access Read-only BIOS Setting FQDD Name biosSettingFQDD Object ID 1.3.6.1.4.1.674.10892.1.1400.90.1.12 Description Fully Qualified Device Descriptor (FQDD) for the BIOS setting. Syntax DisplayString Access Read-only BIOS Group Variable Values This section includes definitions for server administrator-specific variable values used in this section. Table 17-1. Speaker Control Capabilities Unique Variable Name: DellSpeakerControlCapabilitiesUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) Speaker control capabilities are unknown. enableCapable(2) Setup BIOS can enable speaker control. lowCapable(4) Setup BIOS can set the speaker volume to low. mediumCapable(8) Setup BIOS can set the speaker volume to medium. 420 BIOS Setup Control Group Table 17-1. Speaker Control Capabilities Unique (continued) Variable Name: DellSpeakerControlCapabilitiesUnique Data Type: Integer Possible Data Values Meaning of Data Value highCapable(16) Setup BIOS can set the speaker volume to high. allVolumeCapable(30) Setup BIOS can set the speaker volume to any of the three settings. Table 17-2. Speaker Control Settings Unique Variable Name: DellSpeakerControlSettingsUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) Speaker control state is unknown. enabled(2) Speaker control is enabled. low(4) Speaker control volume is low. medium(8) Speaker control volume is medium. high(16) Speaker control volume is high. Table 17-3. Network Interface (NIF) Wakeup on LAN Capabilities Unique Variable Name: DellNIFwakeonLanControlCapabilitiesUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) Setup BIOS Wakeup on LAN capabilities are unknown. enableCapable(2) Setup BIOS is capable of enabling the NIF Wakeup on LAN. addInCardCapable(4) Setup BIOS is capable of enabling Wakeup on LAN by option card. onBoardCapable(8) Setup BIOS is capable of enabling Wakeup on LAN by integrated NIF. BIOS Setup Control Group 421 Table 17-3. Network Interface (NIF) Wakeup on LAN Capabilities Unique (continued) Variable Name: DellNIFwakeonLanControlCapabilitiesUnique Data Type: Integer Possible Data Values Meaning of Data Value bothCapable(14) Setup BIOS is capable of enabling Wakeup on LAN by either option card or integrated NIF. Table 17-4. NIF Wakeup on LAN Control Settings Unique Variable Name: DellNIFwakeonLanControlSettingsUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) NIF Wakeup on LAN state is unknown. enabled(2) NIF Wakeup on LAN is enabled. addInCard(4) NIF Wakeup on LAN is by option card. onBoard(8) NIF Wakeup on LAN is by integrated NIF. addInCardOrOnBoard(12) NIF Wakeup on LAN is by option card or integrated NIF. Table 17-5. Boot Sequence Control Capabilities Unique Variable Name: DellBootSequenceControlCapabilitiesUnique Data Type: Integer Possible Data Values Meaning of Data Value bootSequenceUnknown(1) Boot sequence capabilities are unknown. bootFromDisketteFirstCapable Setup BIOS can boot from a diskette (2) first. bootFromhardDriveFirstCapable Setup BIOS can boot from an IDE hard (4) drive first. bootFromDisketteORHardDrive Setup BIOS can boot from a diskette or FirstCapable(6) an IDE hard drive first. 422 BIOS Setup Control Group Table 17-5. Boot Sequence Control Capabilities Unique (continued) Variable Name: DellBootSequenceControlCapabilitiesUnique Data Type: Integer Possible Data Values Meaning of Data Value bootFromDeviceListCapable(8) Setup BIOS can boot from a device list. bootFromCDROMFirstCapable(16) Setup BIOS can boot from a CD first. allFirstCapable(30) Table 17-6. Setup BIOS can boot by any of the preceding methods first. Boot Sequence Control Settings Unique Variable Name: DellBootSequenceControlSettingsUnique Data Type: Integer Possible Data Values Meaning of Data Value bootSequenceUnknown(1) Boot sequence state is unknown. bootFromDisketteFirst(2) Setup BIOS is set to boot by diskette first. bootFromHardDriveFirst(4) Setup BIOS is set to boot by IDE hard drive first. bootFromDeviceList(8) Setup BIOS is set to boot by a device list. bootFromCDROMFirst(16) Setup BIOS is set to boot by CD first. Table 17-7. BIOS Password Control Capabilities Variable Name: DellBIOSPasswordControlCapabilities Data Type: Integer Possible Data Values Meaning of Data Value passwordControlCapabilitiesUn BIOS password capabilities are known(1) unknown. passwordControlEnableCapable (2) Setup BIOS is capable of enabling password changes. BIOS Setup Control Group 423 Table 17-7. BIOS Password Control Capabilities (continued) Variable Name: DellBIOSPasswordControlCapabilities Data Type: Integer Possible Data Values Meaning of Data Value passwordControlJumperDisable Capable(4) Setup BIOS is capable of determining if password control can be jumper disabled. passwordControlEnableANDJumper Setup BIOS is capable of enabling DisableCapable(6) password changes and of determining if password control can be jumper disabled. Table 17-8. BIOS Password Control Settings Unique Variable Name: DellBIOSPasswordControlSettingsUnique Data Type: Integer Possible Data Values Meaning of Data Value passwordControlSettingsUnknown(1) Setup BIOS password state is unknown. passwordControlEnabled(2) Setup BIOS has password changes enabled. passwordControlJumperDisabled(4) Setup BIOS has determined that password control has been disabled by a jumper. Table 17-9. BIOS Password Control Settings Variable Name: DellBIOSPasswordControlSettingsUnique Data Type: Integer Possible Data Values Meaning of Data Value passwordControlSettingsUnknown(1) Setup BIOS password state is unknown. passwordControlEnabled(2) 424 BIOS Setup Control Group Setup BIOS has password changes enabled. Table 17-9. BIOS Password Control Settings (continued) Variable Name: DellBIOSPasswordControlSettingsUnique Data Type: Integer Possible Data Values Meaning of Data Value passwordControlJumperDisabled(4) Setup BIOS has determined that password control has been disabled by a jumper. Table 17-10. TPM Security Control Capabilities Variable Name: DellTPMSecurityControlCapabilities Data Type: Integer Possible Data Values Meaning of Data Value offCapable(1) TPM security can be Off. onWithPrebootMeasurementsCap TPM security can be On with Pre-boot able(2) Measurements. onWithoutPrebootMeasurements TPM security can be On without Pre-boot Capable(4) Measurements. Table 17-11. TPM Security Control Setting Variable Name: DellTPMSecurityControlSetting Data Type: Integer Possible Data Values Meaning of Data Value off(0) TPM security is Off. onWithPrebootMeasurements(1) TPM security is On with Pre-boot Measurements. onWithoutPrebootMeasurements TPM security is On without Pre-boot (2) Measurements. BIOS Setup Control Group 425 Table 17-12. Parallel Port Control Capabilities Variable Name: DellParallelPortControlCapabilitiesUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) Setup BIOS parallel port capabilities are unknown. enableCapable(2) Setup BIOS can enable the parallel port. lpt1Capable(4) Setup BIOS can support parallel port 1. lpt1andEnableCapable(6) Setup BIOS has enabled parallel port 1. lpt2Capable(8) Setup BIOS can support parallel port 2. lpt2andEnableCapable(10) Setup BIOS has enabled parallel port 2. lpt3Capable(16) Setup BIOS can support parallel port 3. lpt3andEnableCapable(18) Setup BIOS has enabled parallel port 3. allParallelPortCapable(30) Setup BIOS can support any of the three parallel ports. Table 17-13. Parallel Port Control Settings Variable Name: DellParallelPortControlSettingsUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) Parallel port state is unknown. enabled(2) Setup BIOS has enabled the parallel port. lpt1(4) Setup BIOS supports parallel port 1. lpt1Enabled(6) Setup BIOS has enabled parallel port 1. lpt2(8) Setup BIOS supports parallel port 2. lpt2Enabled(10) Setup BIOS has enabled parallel port 2. lpt3(16) Setup BIOS supports parallel port 3. 426 BIOS Setup Control Group Table 17-14. Parallel Port Control Mode Settings Variable Name: DellParallelPortControlModeSettingsUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) Parallel port mode is unknown. atModeEnabled(2) Setup BIOS has set the parallel port to AT mode. ps2ModeEnabled(4) Setup BIOS has set the parallel port to Personal Systems/2 (PS/2) mode. ecpModeEnabled(8) Setup BIOS has set the parallel port to Extended Capabilities Port (ECP) mode. eppModeEnabled(16) Setup BIOS has set the parallel port to Enhanced Parallel Port (EPP) mode. Table 17-15. Serial Port Control Capabilities Variable Name: DellSerialPortControlCapabilitiesUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) Setup BIOS serial port capabilities are unknown. enableCapable(2) Setup BIOS can enable the serial port. com1Capable(4) Setup BIOS can support serial port 1. enableAndCom1Capable(6) Setup BIOS can enable serial port 1. com2Capable(8) Setup BIOS can support serial port 2. enableAndCom2Capable(10) Setup BIOS is capable of enabling serial port 2. com3Capable(16) Setup BIOS can support serial port 3. enableAndCom3Capable(18) Setup BIOS is capable of enabling serial port 3. com4Capable(32) Setup BIOS can support serial port 4. enableAndCom4Capable(34) Setup BIOS is capable of enabling serial port 4. autoConfigCapable(64) Setup BIOS is capable of autoconfiguring all serial ports. BIOS Setup Control Group 427 Table 17-15. Serial Port Control Capabilities (continued) Variable Name: DellSerialPortControlCapabilitiesUnique Data Type: Integer Possible Data Values Meaning of Data Value com1OrCom3CapableAndAuto Setup BIOS has enabled autoconfiguration of ConfigCapable(86) COM1 and COM3 serial ports. com2OrCom4CapableAndAuto Setup BIOS has enabled autoconfiguration of ConfigCapable(106) COM2 and COM4 serial ports. allcomCapable(126) Setup BIOS is capable of enabling or autoconfiguring all serial ports. Table 17-16. Serial Port Control Settings Variable Name: DellSerialPortControlSettingsUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) Serial port state is unknown. enabled(2) Setup BIOS has enabled the serial port. com1(4) Setup BIOS has selected serial port 1. com1Enabled(6) Setup BIOS has enabled serial port 1. com2(8) Setup BIOS has selected serial port 2. com2Enabled(10) Setup BIOS has enabled serial port 2. com3(16) Setup BIOS has selected serial port 3. com3Enabled(18) Setup BIOS has enabled serial port 3. com4(32) Setup BIOS has selected serial port 4. com4Enabled(34) Setup BIOS has enabled serial port 4. comPortsAutoConfig(64) Setup BIOS has selected autoconfiguration of serial ports. enabledAndAutoConfig(66) Setup BIOS has enabled autoconfiguration of serial ports. 428 BIOS Setup Control Group Table 17-17. IDE Control Capabilities Variable Name: DellideControlCapabilitiesUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) IDE control capabilities are unknown. ideControlAutoConfigOrEnable IDE controller is autoconfigurable or Capable(2) enable capable. Table 17-18. Diskette Control Settings Variable Name: DellDisketteControlSettingsUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) Diskette control state is unknown. disketteControlAutoConfigEnabled Diskette control is set as OrEnabled(2) autoconfigurable or enabled. Table 17-19. Network Interface Control Capabilities Variable Name: DellNetworkInterfaceControlCapabilitiesUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) Unknown setup BIOS network interface capabilities. enableCapable(2) Setup BIOS is capable of enabling the network interface. enableWithoutPXECapable(4) Setup BIOS is capable of enabling the NIF without Pre-boot eXecution Environment (PXE). BIOS Setup Control Group 429 Table 17-20. Network Interface Control Settings Variable Name: DellNetworkInterfaceControlSettingsUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) Network interface state is unknown. enabled(2) Network interface is enabled. enabledWithoutPXE(4) Network interface is enabled without PXE. Table 17-21. BIOS Setting Value Type Variable Name: DellBIOSSettingValueType Data Type: Integer Possible Data Values Meaning of Data Value integer(1) Value type is integer. string(2) Value type is string. enumeration(3) Value type is enumeration. orderedList(4) Value type is ordered list. 430 BIOS Setup Control Group Local Response Agent Group 18 The Local Response Agent Group provides information about various attributes of your system’s local response agent (LRA). The LRA allows systems managers to predetermine how a system running the server administrator responds to a particular event type, such as the loss of redundancy in a specific component or the elevation of temperature in a chassis. Systems managers can configure the LRA to respond to an event type with a specific action. When the condition of the critical component worsens, the systems manager can escalate the response to make it more obvious to the operator. For example, when a voltage probe on a monitored machine reaches a warning condition, the systems manager may want to notify the operator by causing the machine to beep. When the voltage probe reaches failure, the systems manager might want to have the system that has a failing component send a broadcast message to the management system and power off the troubled system. LRA Group Tables The following management information base (MIB) tables define LRA variable attributes: • "LRA Global Settings Table" on page 432 • "LRA Action Table" on page 434 LRA Global Settings The global settings table allows the systems manager to determine what LRA capabilities exist for a specific system that is running Server Administrator. Some machines may support all or some of the capabilities described in DellLocalResponseAgentCapabilitiesUnique. The LRA Global Settings Table also defines thermal shutdown capabilities and settings. In the event that a temperature probe determines the temperature is at or over the failure limit, the systems manager can set an action to be taken automatically. Local Response Agent Group 431 LRA Global Settings Table Name lRAGlobalSettingsTable Object ID 1.3.6.1.4.1.674.10892.1.1500.10 Description Defines the LRA Global Settings Table. Syntax SEQUENCE OF LRAGlobalSettingsTableEntry Access Not accessible LRA Global Settings Table Entry Name lRAGlobalSettingsTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1500.10.1 Description Defines the LRA Global Settings Table entry. Syntax LRAGlobalSettingsTableEntry Access Not accessible Index lRAGlobalchassisIndex LRA Global Chassis Index Name lRAGlobalchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1500.10.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only LRA Global State Name lRAGlobalState Object ID 1.3.6.1.4.1.674.10892.1.1500.10.1.2 Description Defines the state of the LRA global settings. Syntax DellStateSettings Access Read-only 432 Local Response Agent Group LRA Global Settings Disable Time-out Value Name lRAGlobalSettingsDisableTimeoutValue Object ID 1.3.6.1.4.1.674.10892.1.1500.10.1.3 Description Defines the time-out duration countdown, in seconds, that the LRA global settings are disabled after a system shutdown and reboot. Syntax DellUnsigned32BitRange Access Read-only LRA Global Settings Capabilities Unique Name lRAGlobalSettingsCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1500.10.1.4 Description Defines the set of global capabilities that all local response agents may or may not allow to be set or reset. Syntax DellLocalResponseAgentCapabilitiesUnique (See Table 18-1) Access Read-only LRA Global Thermal Shutdown Capabilities Unique Name lRAGlobalThermalShutdownCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1500.10.1.5 Description Defines the set of thermal shutdown capabilities that are supported by the LRA. Syntax DellLRAThermalShutdownCapabilitiesUnique Access Read-only LRA Global Thermal Shutdown State Settings Unique Name lRAGlobalThermalShutdownStateSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.1500.10.1.6 Description Defines the set of thermal shutdown state and settings that the local response agent supports. Syntax DellLRAThermalShutdownStateSettingsUnique Access Read-write Local Response Agent Group 433 LRA Action Table The DellLocalResponseAgentCapabilitiesUnique variable in the global action table defines the capabilities that are allowed for a particular system. The LRA Action Table that follows selects which of the system’s capabilities (global actions) are to be enabled. Name lRAActionTableTable Object ID 1.3.6.1.4.1.674.10892.1.1500.20 Description Defines the LRA Action Table. Syntax SEQUENCE OF LRAActionTableTableEntry Access Not accessible LRA Action Table Entry Name lRAActionTableTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1500.20.1 Description Defines the LRA Action Table entry. Syntax LRAActionTableTableEntry Access Not accessible Index lRAActionTablechassisIndex, lRAActionTableActionNumberIndex LRA Action Table Chassis Index Name lRAActionTablechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1500.20.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only 434 Local Response Agent Group LRA Action Table Action Number Index Name lRAActionTableActionNumberIndex Object ID 1.3.6.1.4.1.674.10892.1.1500.20.1.2 Description Defines the LRA action number index. The action number indexes are as follows: • 160 — temperature failure action definition • 168 — cooling device failure action definition • 172 — voltage failure action definition • 200 — temperature warning action definition • 202 — voltage warning action definition • 204 — cooling device warning action definition • 206 — amperage failure action definition • 208 — amperage warning action definition • 210 — a power or cooling unit redundancy lost action definition • 212 — a power or cooling unit redundancy degraded action definition • 214 — power supply failed action definition • 220 — chassis intrusion action definition • 228 — memory device warning action definition • 474 — memory device failure action definition • 1006 — automatic system recovery (ASR) action definition • 1353 — power supply warning action definition • 1553 — log near full action definition • 1554 — log full action definition • 1603 — processor warning action definition • 1604 — processor failure action definition • 1703 — battery warning action definition • 1704 — battery failure action definition Syntax DellUnsigned16BitRange Access Read-only Local Response Agent Group 435 LRA Action Table User Application Name Name lRAActionTableUserApplicationName Object ID 1.3.6.1.4.1.674.10892.1.1500.20.1.3 Description When the execute application value is set, provides the following user-assignable LRA information: • Name of the user application executable path • File name to execute Syntax DisplayString (SIZE (0..256) Access Read-write LRA Action Table Settings Unique Name lRAActionTableSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.1500.20.1.4 Description Defines the LRA settings. Syntax DellLocalResponseAgentSettingsUnique (See Table 18-3) Access Read-write Local Response Agent Variable Values This section includes definitions for server administrator-specific variable values used in this section. Table 18-1. LRA Capabilities Definitions Variable Name: DellLocalResponseAgentCapabilitiesUnique Data Type: Integer Possible Data Values Meaning of Data Value speakerControlCapable(1) The LRA can issue a speaker beep. consoleAlertCapable(2) The LRA can alert the console. broadcastMessageCapable(4) The LRA can broadcast a message. osShutDownCapable(8) The LRA can shut down the operating system. 436 Local Response Agent Group Table 18-1. LRA Capabilities Definitions (continued) Variable Name: DellLocalResponseAgentCapabilitiesUnique Data Type: Integer Possible Data Values Meaning of Data Value rebootCapable(16) The LRA can reboot the system. powerCycleCapable(32) The LRA is capable of a system power cycle. powerOFFCapable(64) The LRA can shut the system power off. executeApplicationCapable(256) The LRA can execute a user mode application. lraFullyCapable(383) Table 18-2. The LRA has all of the preceding capabilities. LRA Thermal Shutdown Capabilities Unique Variable Name: DellLRAThermalShutdownCapabilitiesUnique Data Type: Integer Possible Data Values Meaning of Data Value none(0) The LRA has no thermal shutdown capabilities. Unknown capabilities(1) The LRA’s thermal shutdown capabilities are unknown. enableCapable(2) The LRA can be disabled (offline, a binary 0 value) or enabled (online, a binary 1 value). warningCapable(4) The LRA can carry out chassis-determined action(s) when a warning condition is detected. enableOnWarningCapable(6) The LRA enables activation of chassisdetermined action(s) when a warning condition is detected. failureCapable(8) The LRA can carry out chassis-determined action(s) when a failure condition is detected. Local Response Agent Group 437 Table 18-2. LRA Thermal Shutdown Capabilities Unique (continued) Variable Name: DellLRAThermalShutdownCapabilitiesUnique Data Type: Integer Possible Data Values Meaning of Data Value enableOnFailureCapable(10) The LRA enables activation of chassisdetermined action(s) when a failure condition is detected. The LRA enables activation of chassisdetermined action(s) when either a failure or a warning condition is detected. enableOnWarningOrFailure Capable(14) Table 18-3. Local Response Agent Settings Unique Variable Name: DellLocalResponseAgentSettingsUnique Data Type: Integer Possible Data Values Meaning of Data Value speakerControl(1) LRA is set to issue a speaker beep. consoleAlert(2) LRA is set to issue a console alert. broadcastMessage(4) LRA is set to issue a broadcast message. osShutDown(8) LRA is set to issue an operating system shutdown. reboot(16) LRA is set to issue a system reboot. powerCycle(32) LRA is set to issue a system power cycle. powerOFF(64) LRA is set to issue a system power off. executeApplication(256) LRA is set to start a user mode application. allLRASettingsUnique(383) LRA is set to all LRA settings combinations. 438 Local Response Agent Group Cost of Ownership Group 19 The Cost of Ownership (COO) Group provides a full set of cost-tracking objects, including fields for the computer’s manufacturer, insurer, lessor, warranty, user, trouble tickets, and many others. You can use these management information base (MIB) objects to obtain accurate and complete measurements of the cost of each computer asset in your organization. Cost of Ownership Group Tables The Cost of Ownership Group defines objects in the following MIB tables: • "Cost of Ownership Table" on page 439 • "COO Service Contract Table" on page 450 • "COO Cost Event Log Table" on page 452 • "COO Warranty Table" on page 454 • "COO Lease Information Table" on page 456 • "COO Schedule Number Table" on page 459 • "COO Options Table" on page 460 • "COO Maintenance Table" on page 462 • "COO Repair Table" on page 464 • "COO Support Information Table" on page 466 • "COO Trouble Ticket Table" on page 468 Cost of Ownership Table The following MIB object sets up the Cost of Ownership Table. Name cooTable Object ID 1.3.6.1.4.1.674.10892.1.1600.10 Description Defines the Cost of Ownership Table. Syntax SEQUENCE OF CooTableEntry Access Not accessible Cost of Ownership Group 439 Cost of Ownership Table Entry Name cooTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1 Description Defines the Cost of Ownership Table entry. Syntax CooTableEntry Access Not accessible Index coochassisIndex COO Chassis Index Name coochassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.1 Description Defines the index (one-based) of this chassis. Syntax CooTableEntry Access Read-only COO State Name cooState Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.2 Description Defines the acquisition state of the system. Syntax DellStateSettings Access Read-only COO Acquisition Purchase Cost Name cooAquisitionPurchaseCost Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.3 Description Defines the purchase cost of the system. Syntax DellUnsigned32BitRange Access Read-write 440 Cost of Ownership Group COO Acquisition Waybill Number Name cooAquisitionWayBillNumber Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.4 Description Defines the waybill number of the system. Syntax DellUnsigned32BitRange Access Read-write COO Acquisition Install Date Name Name cooAquisitionInstallDateName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.5 Description Defines the installation date and time for the system. Syntax DellDateName Access Read-write COO Acquisition Purchase Order Name cooAquisitionPurchaseOrder Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.6 Description Defines the purchase order number of the system. Syntax DellUnsigned32BitRange Access Read-write COO Acquisition Purchase Date Name Name cooAquisitionPurchaseDateName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.7 Description Defines the purchase date and time of the system. Syntax DellDateName Access Read-write Cost of Ownership Group 441 COO Acquisition Signing Authority Name Name cooAquisitionSigningAuthorityName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.8 Description Defines the name of the authorized person who signs for the system. Syntax DellCostofOwnershipString Access Read-write COO Original Machine Configuration Expensed Name cooOriginalMachineConfigurationExpensed Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.9 Description Specifies whether the purchase of this system was expensed. Syntax DellBoolean Access Read-write COO Original Machine Configuration Vendor Name Name cooOriginalMachineConfigurationVendorName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.10 Description Defines the vendor name of the system. Syntax DellCostofOwnershipString Access Read-only COO Cost Center Information Vendor Name Name cooCostCenterInformationVendorName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.11 Description Defines the cost center name of the system. Syntax DellCostofOwnershipString Access Read-write 442 Cost of Ownership Group COO User Information User Name Name cooUserInformationUserName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.12 Description Defines the name of the user for this system. Syntax DellCostofOwnershipString Access Read-write COO Extended Warranty Start Date Name Name cooExtendedWarrantyStartDateName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.13 Description Defines the extended warranty start date for this system. Syntax DellDateName Access Read-write COO Extended Warranty End Date Name Name cooExtendedWarrantyEndDateName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.14 Description Defines the extended warranty end date for this system. Syntax DellDateName Access Read-write COO Extended Warranty Cost Name cooExtendedWarrantyCost Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.15 Description Defines the extended warranty cost date for this system. Syntax DellUnsigned32BitRange Access Read-write Cost of Ownership Group 443 COO Extended Warranty Provider Name Name cooExtendedWarrantyProviderName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.16 Description Defines the name of the extended warranty provider for this system. Syntax DellCostofOwnershipString Access Read-write COO Ownership Code Name cooOwnershipCode Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.17 Description Defines the ownership code for this system. Syntax DellCooOwnershipCodes (See Table 19-1) Access Read-write COO Corporate Owner Name Name cooCorporateOwnerName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.18 Description Defines the name of the corporation that owns this system. Syntax DellCostofOwnershipString Access Read-write COO Hazardous Waste Code Name Name cooHazardousWasteCodeName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.19 Description Defines the hazardous waste code for this system. Syntax DellCostofOwnershipString Access Read-write 444 Cost of Ownership Group COO Deployment Date Length Name cooDeploymentDateLength Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.20 Description Defines the deployment time for this system. Syntax DellUnsigned32BitRange Access Read-write COO Deployment Duration Type Name cooDeploymentDurationType Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.21 Description Defines the deployment time units for this system. Syntax DellCooHourDayDurationType (See Table 19-2) Access Read-write COO Training Name Name cooTrainingName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.22 Description Defines the training that the user has for this system. Syntax DellCostofOwnershipString Access Read-write COO Outsourcing Problem Description Name Name cooOutsourcingProblemDescriptionName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.23 Description Defines a problem encountered with the outsourcing service provider. Syntax DellCostofOwnershipString Access Read-write Cost of Ownership Group 445 COO Outsourcing Service Fee Name Name cooOutsourcingServiceFeeName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.24 Description Defines amount that the outsourcing vendor charges for service. Syntax DellCostofOwnershipString Access Read-write COO Outsourcing Signing Authority Name Name cooOutsourcingSigningAuthorityName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.25 Description Defines the name of the person who can sign the authorization for service. Syntax DellCostofOwnershipString Access Read-write COO Outsourcing Provider Fee Name Name cooOutsourcingProviderFeeName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.26 Description Defines any additional outsourcing charge for service. Syntax DellCostofOwnershipString Access Read-write COO Outsourcing Provider Service Level Name Name cooOutsourcingProviderServiceLevelName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.27 Description Defines the service level agreement for the system. Syntax DellCostofOwnershipString Access Read-write 446 Cost of Ownership Group COO Insurance Company Name Name cooInsuranceCompanyName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.28 Description Defines the name of the company that insures this system. Syntax DellCostofOwnershipString Access Read-write COO Box Asset Tag Name Name cooBoxAssetTagName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.29 Description Defines the name of the asset tag. Syntax DellCostofOwnershipString Access Read-write COO Box System Name Name cooBoxSystemName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.30 Description Defines the name of the system. Syntax DellCostofOwnershipString Access Read-write COO Box Central Processing Unit (CPU) Serial Number Name Name cooBoxCPUSerialNumberName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.31 Description Defines the name of the CPU serial number for the system. Syntax DellCostofOwnershipString Access Read-write Cost of Ownership Group 447 COO Operating System Upgrade Type Name Name cooOperatingSystemUpgradeTypeName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.32 Description Defines the name of the operating system on this system. Syntax DellCostofOwnershipString Access Read-write COO Operating System Upgrade Patch Level Name Name cooOperatingSystemUpgradePatchLevelName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.33 Description Defines the name of the operating system patch level for this system. Syntax DellCostofOwnershipString Access Read-write COO Operating System Upgrade Date Name cooOperatingSystemUpgradeDate Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.34 Description Defines the upgrade file date for this operating system. Syntax DellCostofOwnershipString Access Read-write COO Depreciation Duration Name cooDepreciationDuration Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.35 Description Defines the length of depreciation for this system. Syntax DellUnsigned32BitRange Access Read-write 448 Cost of Ownership Group COO Depreciation Duration Type Name cooDepreciationDurationType Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.36 Description Defines the unit of time for the depreciation of this system. Syntax DellCooMonthYearDurationType Access Read-write COO Depreciation Percentage Name cooDepreciationPercentage Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.37 Description Defines the percentage of depreciation for this system. Syntax DellUnsigned32BitRange Access Read-write COO Depreciation Method Name Name cooDepreciationMethodName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.38 Description Defines the name of the depreciation method for this system. Syntax DellCostofOwnershipString Access Read-write COO Registration Is Registered Name cooRegistrationIsRegistered Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.39 Description Specifies whether this system is registered or not. Syntax DellBoolean Access Read-write Cost of Ownership Group 449 COO Service Contract Table The service contract table provides MIB objects that help you track the name, vendor, and type of service contract you have for your system. Name cooServiceContractTable Object ID 1.3.6.1.4.1.674.10892.1.1600.20 Description Defines the COO Service Contract Table. Syntax SEQUENCE OF CooServiceContractTableEntry Access Not accessible COO Service Contract Table Entry Name cooServiceContractTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1600.20.1 Description Defines the COO Service Contract Table entry. Syntax CooServiceContractTableEntry Access Not accessible Index cooServiceContractchassisIndex, cooServiceContractIndex COO Service Contract Chassis Index Name cooServiceContractchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.20.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only COO Service Contract Index Name cooServiceContractIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.20.1.2 Description Defines the index (one-based) of this service contract. Syntax DellObjectRange Access Read-only 450 Cost of Ownership Group COO Service Contract State Name cooServiceContractState Object ID 1.3.6.1.4.1.674.10892.1.1600.20.1.3 Description Defines the status of the service contract for this system. Syntax DellStateSettings Access Read-only COO Service Contract Was Renewed Name cooServiceContractWasRenewed Object ID 1.3.6.1.4.1.674.10892.1.1600.20.1.4 Description Specifies whether the service contract for this system was renewed. Syntax DellBoolean Access Read-write COO Service Contract Type Name Name cooServiceContractTypeName Object ID 1.3.6.1.4.1.674.10892.1.1600.20.1.5 Description Defines the name of the service contract type for this system. Syntax DellCostofOwnershipString Access Read-write COO Service Contract Vendor Name Name cooServiceContractVendorName Object ID 1.3.6.1.4.1.674.10892.1.1600.20.1.6 Description Defines the name of the service contract provider for this system. Syntax DellCostofOwnershipString Access Read-write Cost of Ownership Group 451 COO Cost Event Log Table The COO Cost Event Log Table provides MIB objects that allow you to track the duration and type of events that are logged for a particular system. Name cooCostEventLogTable Object ID 1.3.6.1.4.1.674.10892.1.1600.30 Description Defines the COO Cost Event Log Table. Syntax SEQUENCE OF COO CostEventLogTableEntry Access Not accessible COO Cost Event Log Table Entry Name cooCostEventLogTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1600.30.1 Description Defines the COO Cost Event Log Table entry. Syntax cooCostEventLogTableEntry Access Not accessible Index cooCostEventLogchassisIndex, cooCostEventLogIndex COO Cost Event Log Chassis Index Name cooCostEventLogchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.30.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only COO Cost Event Log Index Name cooCostEventLogIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.30.1.2 Description Defines the index (one-based) of the cost event log. Syntax DellObjectRange Access Read-only 452 Cost of Ownership Group COO Cost Event Log State Name cooCostEventLogState Object ID 1.3.6.1.4.1.674.10892.1.1600.30.1.3 Description Defines the cost event log state of this system. Syntax DellStateSettings Access Read-only COO Cost Event Log Duration Name cooCostEventLogDuration Object ID 1.3.6.1.4.1.674.10892.1.1600.30.1.4 Description Defines the duration of the event for this system. Syntax DellUnsigned32BitRange Access Read-write COO Cost Event Log Duration Type Name cooCostEventLogDurationType Object ID 1.3.6.1.4.1.674.10892.1.1600.30.1.5 Description Defines the duration type of the event for this system. Syntax DellCOOHourDayDurationType (See Table 19-2) Access Read-write COO Cost Event Log Description Name Name cooCostEventLogDescriptionName Object ID 1.3.6.1.4.1.674.10892.1.1600.30.1.6 Description Defines the name of the event description. Syntax DellCostofOwnershipString Access Read-write Cost of Ownership Group 453 COO Warranty Table The COO Warranty Table objects enable you to track facts about the type and duration of the warranty for a particular system. Name cooWarrantyTable Object ID 1.3.6.1.4.1.674.10892.1.1600.40 Description Defines the COO Warranty Table. Syntax SEQUENCE OF CooWarrantyTableEntry Access Not accessible COO Warranty Table Entry Name cooWarrantyTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1600.40.1 Description Defines the COO Warranty Table entry. Syntax CooWarrantyTableEntry Access Not accessible Index cooWarrantychassisIndex, cooWarrantyIndex COO Warranty Chassis Index Name cooWarrantychassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.40.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-write COO Warranty Index Name cooWarrantyIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.40.1.2 Description Defines the index of the warranty for this system. Syntax DellObjectRange Access Read-only 454 Cost of Ownership Group COO Warranty State Name cooWarrantyState Object ID 1.3.6.1.4.1.674.10892.1.1600.40.1.3 Description Defines the state of the warranty for this system. Syntax DellStateSettings Access Read-only COO Warranty Duration Name cooWarrantyDuration Object ID 1.3.6.1.4.1.674.10892.1.1600.40.1.4 Description Defines the duration of the warranty. Syntax DellUnsigned32BitRange Access Read-write COO Warranty Duration Type Name cooWarrantyDurationType Object ID 1.3.6.1.4.1.674.10892.1.1600.40.1.5 Description Defines the warranty duration type for the system. Syntax DellCOODayMonthDurationType Access Read-write COO Warranty End Date Name Name cooWarrantyEndDateName Object ID 1.3.6.1.4.1.674.10892.1.1600.40.1.6 Description Defines the warranty end date for this system. Syntax DellDateName Access Read-write Cost of Ownership Group 455 COO Warranty Cost Name cooWarrantyCost Object ID 1.3.6.1.4.1.674.10892.1.1600.40.1.7 Description Defines the cost of the warranty for this system. Syntax DellUnsigned32BitRange Access Read-write COO Lease Information Table The COO lease information MIB objects enable you to track information about your lessor, lease duration, and lease type for each system. Name cooLeaseInformationTable Object ID 1.3.6.1.4.1.674.10892.1.1600.50 Description Defines the COO Lease Information Table. Syntax SEQUENCE OF CooLeaseInformationTableEntry Access Not accessible COO Lease Information Table Entry Name cooLeaseInformationTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1600.50.1 Description Defines the COO Lease Information Table entry. Syntax CooLeaseInformationTableEntry Access Not accessible Index cooLeaseInformationchassisIndex, cooLeaseInformationIndex COO Lease Information Chassis Index Name cooLeaseInformationchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.50.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only 456 Cost of Ownership Group COO Lease Information Index Name cooLeaseInformationIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.50.1.2 Description Defines the index of the lease information for this system. Syntax DellObjectRange Access Read-only COO Lease Information State Name cooLeaseInformationState Object ID 1.3.6.1.4.1.674.10892.1.1600.50.1.3 Description Defines the lease information state for this system. Syntax DellStateSettings Access Read-write COO Lease Information Multiple Schedules Name cooLeaseInformationMultipleSchedules Object ID 1.3.6.1.4.1.674.10892.1.1600.50.1.4 Description Defines whether there are multiple schedules for this lease. Syntax DellBoolean Access Read-only COO Lease Information Buyout Amount Name cooLeaseInformationBuyOutAmount Object ID 1.3.6.1.4.1.674.10892.1.1600.50.1.5 Description Defines the balance purchase price for this system. Syntax DellUnsigned32BitRange Access Read-write Cost of Ownership Group 457 COO Lease Information Lease Rate Factor Name cooLeaseInformationLeaseRateFactor Object ID 1.3.6.1.4.1.674.10892.1.1600.50.1.6 Description Defines the rate factor for the lease on this system. Syntax DellUnsigned32BitRange Access Read-write COO Lease Information End Date Name Name cooLeaseInformationEndDateName Object ID 1.3.6.1.4.1.674.10892.1.1600.50.1.7 Description Defines the end date for the lease on this system. Syntax DellDateName Access Read-write COO Lease Information Fair Market Value Name cooLeaseInformationFairMarketValue Object ID 1.3.6.1.4.1.674.10892.1.1600.50.1.8 Description Defines the fair market value of this system. Syntax DellUnsigned32BitRange Access Read-write COO Lease Information Lessor Name Name cooLeaseInformationLessorName Object ID 1.3.6.1.4.1.674.10892.1.1600.50.1.9 Description Defines the name of the lessor of this system. Syntax DellCostofOwnershipString Access Read-write 458 Cost of Ownership Group COO Schedule Number Table Name cooScheduleNumberTable Object ID 1.3.6.1.4.1.674.10892.1.1600.60 Description Defines the COO Schedule Number Information Table. Syntax SEQUENCE OF CooScheduleNumberTableEntry Access Not accessible COO Schedule Number Table Entry Name cooScheduleNumberTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1600.60.1 Description Defines the COO Schedule Number Information Table entry. Syntax CooScheduleNumberTableEntry Access Not accessible Index cooScheduleNumberchassisIndex, cooScheduleNumberIndex COO Schedule Number Chassis Index Name cooScheduleNumberchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.60.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only COO Schedule Number Index Name cooScheduleNumberIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.60.1.2 Description Defines the index of the schedule number information. Syntax DellObjectRange Access Read-only Cost of Ownership Group 459 COO Schedule Number State Name cooScheduleNumberState Object ID 1.3.6.1.4.1.674.10892.1.1600.60.1.3 Description Defines the schedule number information state of this system. Syntax DellStateSettings Access Read-only COO Schedule Number Lease Information Index Reference Name cooScheduleNumberLeaseInformationIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1600.60.1.4 Description Defines the lease information index number to reference the schedule number. Syntax DellUnsigned32BitRange Access Read-write COO Schedule Number Description Name Name cooScheduleNumberDescriptionName Object ID 1.3.6.1.4.1.674.10892.1.1600.60.1.5 Description Describes the schedule number information. Syntax DellCostofOwnershipString Access Read-write COO Options Table Name cooOptionsTable Object ID 1.3.6.1.4.1.674.10892.1.1600.70 Description Defines the COO Options Table. Syntax SEQUENCE OF CooOptionsTableEntry Access Not accessible 460 Cost of Ownership Group COO Options Table Entry Name cooOptionsTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1600.70.1 Description Defines the COO Options Table entry. Syntax CooOptionsTableEntry Access Not accessible Index cooOptionschassisIndex, cooOptionsIndex COO Options Chassis Index Name cooOptionschassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.70.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only COO Options Index Name cooOptionsIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.70.1.2 Description Defines the index (one-based) of the option information for this system. Syntax DellObjectRange Access Read-only COO Options State Name cooOptionsState Object ID 1.3.6.1.4.1.674.10892.1.1600.70.1.3 Description Defines the option information state for this system. Syntax DellStateSettings Access Read-only Cost of Ownership Group 461 COO Options Lease Information Index Reference Name cooOptionsLeaseInformationIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1600.70.1.4 Description Defines the lease information index of the option information for this system. Syntax DellUnsigned32BitRange Access Read-write COO Options Description Name Name cooOptionsDescriptionName Object ID 1.3.6.1.4.1.674.10892.1.1600.70.1.5 Description Defines the option information description name. Syntax DellCostofOwnershipString Access Read-write COO Maintenance Table Name cooMaintenanceTable Object ID 1.3.6.1.4.1.674.10892.1.1600.80 Description Defines the COO Maintenance Table. Syntax SEQUENCE OF CooMaintenanceTableEntry Access Not accessible COO Maintenance Table Entry Name cooMaintenanceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1600.80.1 Description Defines the COO Maintenance Table entry. Syntax CooMaintenanceTableEntry Access Not accessible Index cooMaintenancechassisIndex, cooMaintenanceIndex 462 Cost of Ownership Group COO Maintenance Chassis Index Name cooMaintenancechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.80.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only COO Maintenance Index Name cooMaintenanceIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.80.1.2 Description Defines the index of this system’s maintenance information. Syntax DellObjectRange Access Read-only COO Maintenance State Name cooMaintenanceState Object ID 1.3.6.1.4.1.674.10892.1.1600.80.1.3 Description Defines the state of this system’s maintenance information. Syntax DellStateSettings Access Read-only COO Maintenance Start Date Name Name cooMaintenanceStartDateName Object ID 1.3.6.1.4.1.674.10892.1.1600.80.1.4 Description Defines the start date for maintenance on this system. Syntax DellDateName Access Read-write Cost of Ownership Group 463 COO Maintenance End Date Name Name cooMaintenanceEndDateName Object ID 1.3.6.1.4.1.674.10892.1.1600.80.1.5 Description Defines the end date for maintenance on this system. Syntax DellDateName Access Read-write COO Maintenance Provider Name Name cooMaintenanceProviderName Object ID 1.3.6.1.4.1.674.10892.1.1600.80.1.6 Description Defines the maintenance provider’s name. Syntax DellStateSettings Access Read-write COO Maintenance Restrictions Name Name cooMaintenanceRestrictionsName Object ID 1.3.6.1.4.1.674.10892.1.1600.80.1.7 Description Defines the maintenance agreement restrictions. Syntax DellCostofOwnershipString Access Read-write COO Repair Table Name cooRepairTable Object ID 1.3.6.1.4.1.674.10892.1.1600.90 Description Defines the COO Repair Table. Syntax SEQUENCE OF CooRepairTableEntry Access Not accessible 464 Cost of Ownership Group COO Repair Table Entry Name cooRepairTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1600.90.1 Description Defines the COO Repair Table entry. Syntax CooRepairTableEntry Access Not accessible Index cooRepairchassisIndex, cooRepairIndex COO Repair Chassis Index Name cooRepairchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.90.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only COO Repair Index Name cooRepairIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.90.1.2 Description Defines the index (one-based) of the repair information for this system. Syntax DellObjectRange Access Read-only COO Repair State Name cooRepairState Object ID 1.3.6.1.4.1.674.10892.1.1600.90.1.3 Description Defines the state of the repair information for this system. Syntax DellStateSettings Access Read-only Cost of Ownership Group 465 COO Repair Counter Name cooRepairCounter Object ID 1.3.6.1.4.1.674.10892.1.1600.90.1.4 Description Defines the number of repairs that this system has undergone. Syntax DellCostofOwnershipString Access Read-write COO Repair Vendor Name Name cooRepairVendorName Object ID 1.3.6.1.4.1.674.10892.1.1600.90.1.5 Description Defines the name of the vendor that repairs this system. Syntax DellStateSettings Access Read-only COO Support Information Table Name cooSupportInformationTable Object ID 1.3.6.1.4.1.674.10892.1.1600.100 Description Defines the COO Support Information Table. Syntax SEQUENCE OF cooSupportInformationTableEntry Access Not accessible COO Support Information Table Entry Name cooSupportInformationTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1600.100.1 Description Defines the COO Support Information Table entry. Syntax cooSupportInformationTableEntry Access Not accessible Index cooSupportInformationchassisIndex cooSupportInformationIndex 466 Cost of Ownership Group COO Support Information Chassis Index Name cooSupportInformationchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.100.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only COO Support Information Index Name cooSupportInformationIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.100.1.2 Description Defines the index (one-based) for this system’s support information. Syntax DellObjectRange Access Read-only COO Support Information State Name cooSupportInformationState Object ID 1.3.6.1.4.1.674.10892.1.1600.100.1.3 Description Defines the support information state for this system. Syntax DellStateSettings Access Read-only COO Support Information Is Outsourced Name cooSupportInformationIsOutsourced Object ID 1.3.6.1.4.1.674.10892.1.1600.100.1.4 Description Specifies whether the support for this system is outsourced or not. Syntax DellBoolean Access Read-write Cost of Ownership Group 467 COO Support Information Type Name cooSupportInformationType Object ID 1.3.6.1.4.1.674.10892.1.1600.100.1.5 Description Defines the type of component, system, or network problem that occurred. Syntax DellUnsigned32BitRange Access Read-write COO Support Information Help Desk Name Name cooSupportInformationHelpDeskName Object ID 1.3.6.1.4.1.674.10892.1.1600.100.1.6 Description Defines the help desk information provided. Syntax DellCostofOwnershipString Access Read-write COO Support Information Fix Type Name Name cooSupportInformationFixTypeName Object ID 1.3.6.1.4.1.674.10892.1.1600.100.1.7 Description Defines the method used to fix the problem. Syntax DellCostofOwnershipString Access Read-write COO Trouble Ticket Table The MIB objects in the Trouble Ticket Table enable you to track details of any trouble tickets that you open for your system. Name cooTroubleTicketTable Object ID 1.3.6.1.4.1.674.10892.1.1600.110 Description Defines the COO Trouble Ticket Table. Syntax SEQUENCE OF cooTroubleTicketTableEntry Access Not accessible 468 Cost of Ownership Group COO Trouble Ticket Table Entry Name cooTroubleTicketTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1600.110.1 Description Defines the COO Trouble Ticket Table entry. Syntax cooTroubleTicketTableEntry Access Not accessible Index cooTroubleTicketchassisIndex, cooTroubleTicketIndex COO Trouble Ticket Chassis Index Name cooTroubleTicketchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.110.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only COO Trouble Ticket Index Name cooTroubleTicketIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.110.1.2 Description Defines the index (one-based) of the system’s trouble ticket information. Syntax DellObjectRange Access Read-only COO Trouble Ticket State Name cooTroubleTicketState Object ID 1.3.6.1.4.1.674.10892.1.1600.110.1.3 Description Defines the trouble ticket information state for this system. Syntax DellStateSettings Access Read-only Cost of Ownership Group 469 COO Trouble Ticket Support Information Index Reference Name cooTroubleTicketSupportInformationIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1600.110.1.4 Description Defines the support information index that references the trouble ticket. Syntax DellUnsigned32BitRange Access Read-write COO Trouble Ticket Number Name Name cooTroubleTicketNumberName Object ID 1.3.6.1.4.1.674.10892.1.1600.110.1.5 Description Defines the trouble ticket number for this system. Syntax DellCostofOwnershipString Access Read-write Cost of Ownership Variable Values This section includes definitions for server administrator-specific variable values used in this section. Table 19-1. COO Ownership Codes Variable Name: DellCooOwnershipCodes Data Type: Integer Possible Data Values Meaning of Data Value other(1) The ownership code is not one of following: unknown(2) The ownership code is unknown. owned(3) The ownership code is owned. leased(4) The ownership code is leased. rented(5) The ownership code is rented. offOfLease(6) The ownership code is off of lease. transfer(7) The ownership code is transfer. 470 Cost of Ownership Group Table 19-2. COO Hour Day Duration Type Variable Name: DellCooHourDayDurationType Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) Duration time type is unknown. hours(2) Duration time type is in hours. days(3) Duration time type is in days. Table 19-3. COO Day Month Duration Type Variable Name: DellCooDayMonthDurationType Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) Duration time type is unknown. days(3) Duration time type is in days. months(4) Duration time type is in months. Table 19-4. COO Month Year Duration Type Variable Name: DellCooMonthYearDurationType Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) Duration time type is unknown. months(4) Duration time type is in months. years(5) Duration time type is in years. Cost of Ownership Group 471 472 Cost of Ownership Group Remote Access Group 20 The Remote Access Group provides information about the remote access hardware that may be present in your system. In addition to providing general information about the capabilities and settings of the remote access hardware, this group provides information about administrative users, SNMP trap destinations, modem configuration for dial-up networking, dial-in configuration, and dial-out destinations. DRAC 4 and DRAC 5 On systems with Dell Remote Access Controller (DRAC) 4 or DRAC 5, the Remote Access Group includes only the Remote Access Table. Remote Access Table The following MIB object sets up the Remote Access Table. Name remoteAccessTable Object ID 1.3.6.1.4.1.674.10892.1.1700.10 Description Defines the Remote Access Table. Syntax SEQUENCE OF RemoteAccessTableEntry Access Not accessible Remote Access Table Entry Name remoteAccessTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1 Description Defines the Remote Access Table entry. Syntax RemoteAccessTableEntry Access Not accessible Index remoteAccessChassisIndex, remoteAccessAdapterIndex Remote Access Group 473 Remote Access Chassis Index Name remoteAccessChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.1 Description Defines the index (one-based) of the chassis containing the remote access hardware. Syntax DellObjectRange Access Read-only Remote Access Adapter Index Name remoteAccessAdapterIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.2 Description Defines the index (one-based) of the remote access hardware. Syntax DellObjectRange Access Read-only Remote Access Type Name remoteAccessType Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.3 Description Defines the type of remote access hardware. Syntax DellRemoteAccessType (See Table 20-1) Access Read-only Remote Access State Capabilities Name remoteAccessStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.4 Description Defines the state capabilities of the remote access hardware. Syntax DellStateCapabilities Access Read-only 474 Remote Access Group Remote Access State Settings Name remoteAccessStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.5 Description Defines the state setting of the remote access hardware. Syntax DellStateSettings Access Read-write Remote Access Status Name remoteAccessStatus Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.6 Description Defines the status of the remote access hardware. Syntax DellStatus Access Read-only Remote Access Product Info Name Name remoteAccessProductInfoName Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.7 Description Defines the name of the product providing the remote access functionality. Syntax DellDisplayString (SIZE (0..63)) Access Read-only Remote Access Description Info Name Name remoteAccessDescriptionInfoName Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.8 Description Defines the description of the product providing the remote access functionality. Syntax DellDisplayString (SIZE (0..255)) Access Read-only Remote Access Group 475 Remote Access Version Info Name Name remoteAccessVersionInfoName Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.9 Description Defines the version of the product providing the remote access functionality. Syntax DellDisplayString (SIZE (0..63)) Access Read-only Remote Access Local Area Network (LAN) Capabilities Name remoteAccessLANCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.14 Description Defines the LAN capabilities of the remote access hardware. Syntax DellRemoteAccessLANCapabilities (See Table 20-6) Access Read-only Remote Access LAN Settings Name remoteAccessLANSettings Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.15 Description Defines the LAN settings of the remote access hardware. Syntax DellRemoteAccessLANSettings (See Table 20-7) Access Read-write Remote Access Network Interface Controller (NIC) Static IP Address Name remoteAccessNICStaticIPAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.25 Description Defines the static IP address to be used by the integrated NIC provided by the remote access hardware. Syntax IpAddress Access Read-write 476 Remote Access Group Remote Access NIC Static Netmask Address Name remoteAccessNICStaticNetmaskAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.26 Description Defines the netmask for the static IP address to be used by the integrated NIC provided by the remote access hardware. Syntax IpAddress Access Read-write Remote Access NIC Static Gateway Address Name remoteAccessNICStaticGatewayAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.27 Description Defines the IP address for the gateway associated with the static IP address to be used by the integrated NIC provided by the remote access hardware. Syntax IpAddress Access Read-write Remote Access Personal Computer Memory Card International Association (PCMCIA) Info Name Name remoteAccessPCMCIAInfoName Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.28 Description Defines the information for the PCMCIA device used by the remote access hardware. Syntax DisplayString (SIZE (0..63)) Access Read-only Remote Access Group 477 Remote Access Miscellaneous Information Name Name remoteAccessMiscInfoName Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.29 Description Defines the miscellaneous information for the remote access hardware. Syntax DisplayString (SIZE (0..63)) Access Read-write Remote Access NIC Current IP Address Name remoteAccessNICCurrentIPAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.30 Description Defines the IP address currently being used by the integrated NIC provided by the remote access hardware. Syntax IpAddress Access Read-only Remote Access NIC Current Netmask Address Name remoteAccessNICCurrentNetmaskAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.31 Description Defines the netmask currently being used by the integrated NIC provided by the remote access hardware. Syntax IpAddress Access Read-only Remote Access NIC Current Gateway Address Name remoteAccessNICCurrentGatewayAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.32 Description Defines the IP address for the gateway currently being used by the integrated NIC provided by the remote access hardware. Syntax IpAddress Access Read-only 478 Remote Access Group Remote Access NIC Current Information From Dynamic Host Configuration Protocol (DHCP) Name remoteAccessNICCurrentInfoFromDHCP Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.33 Description Defines whether DHCP was used to obtain the NIC information currently being used by the integrated NIC provided by the remote access hardware. Syntax DellBoolean Access Read-only Remote Access Remote Connect URL Name remoteAccessRemoteConnectURL Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.34 Description Defines the URL for launching the Remote Access Remote Connect Interface. Syntax DisplayString (SIZE (0..63)) Access Mandatory DRAC III On systems with DRAC III, the Remote Access Group includes the following MIB tables: • "Remote Access Table" on page 480 • "Remote User Administration Table" on page 489 • "Remote SNMP Trap Table" on page 497 • "Remote Dial-Up Table" on page 502 • "Remote User Dial-In Configuration Table" on page 506 • "Remote Dial-Out Table" on page 509 Remote Access Group 479 Remote Access Table The following MIB object sets up the Remote Access Table. Name remoteAccessTable Object ID 1.3.6.1.4.1.674.10892.1.1700.10 Description Defines the Remote Access Table. Syntax SEQUENCE OF RemoteAccessTableEntry Access Not accessible Remote Access Table Entry Name remoteAccessTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1 Description Defines the Remote Access Table entry. Syntax RemoteAccessTableEntry Access Not accessible Index remoteAccessChassisIndex, remoteAccessAdapterIndex Remote Access Chassis Index Name remoteAccessChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.1 Description Defines the index (one-based) of the chassis containing the remote access hardware. Syntax DellObjectRange Access Read-only Remote Access Adapter Index Name remoteAccessAdapterIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.2 Description Defines the index (one-based) of the remote access hardware. Syntax DellObjectRange Access Read-only 480 Remote Access Group Remote Access Type Name remoteAccessType Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.3 Description Defines the type of remote access hardware. Syntax DellRemoteAccessType (See Table 20-1) Access Read-only Remote Access State Capabilities Name remoteAccessStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.4 Description Defines the state capabilities of the remote access hardware. Syntax DellStateCapabilities Access Read-only Remote Access State Settings Name remoteAccessStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.5 Description Defines the state setting of the remote access hardware. Syntax DellStateSettings Access Read-write Remote Access Status Name remoteAccessStatus Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.6 Description Defines the status of the remote access hardware. Syntax DellStatus Access Read-only Remote Access Group 481 Remote Access Product Info Name Name remoteAccessProductInfoName Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.7 Description Defines the name of the product providing the remote access functionality. Syntax DellDisplayString (SIZE (0..63)) Access Read-only Remote Access Description Info Name Name remoteAccessDescriptionInfoName Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.8 Description Defines the description of the product providing the remote access functionality. Syntax DellDisplayString (SIZE (0..255)) Access Read-only Remote Access Version Info Name Name remoteAccessVersionInfoName Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.9 Description Defines the version of the product providing the remote access functionality. Syntax DellDisplayString (SIZE (0..63)) Access Read-only Remote Access Control Capabilities Name remoteAccessControlCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.10 Description Defines the control capabilities of the remote access hardware. Syntax DellRemoteAccessControlCapabilities (See Table 20-2) Access Read-only 482 Remote Access Group Remote Access Control Settings Name remoteAccessControlSettings Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.11 Description Defines the control settings of the remote access hardware. Syntax DellRemoteAccessControlSettings (See Table 20-3) Access Read-write Remote Access Monitor Capabilities Name remoteAccessMonitorCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.12 Description Defines the monitor capabilities of the remote access hardware. Syntax DellRemoteAccessMonitorCapabilities (See Table 20-4) Access Read-only Remote Access Monitor Settings Name remoteAccessMonitorSettings Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.13 Description Defines the monitor settings of the remote access hardware. Syntax DellRemoteAccessMonitorSettings (See Table 20-5) Access Read-write Remote Access Local Area Network (LAN) Capabilities Name remoteAccessLANCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.14 Description Defines the LAN capabilities of the remote access hardware. Syntax DellRemoteAccessLANCapabilities (See Table 20-6) Access Read-only Remote Access Group 483 Remote Access LAN Settings Name remoteAccessLANSettings Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.15 Description Defines the LAN settings of the remote access hardware. Syntax DellRemoteAccessLANSettings (See Table 20-7) Access Read-write Remote Access Host Capabilities Name remoteAccessHostCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.16 Description Defines the host capabilities of the remote access hardware. Syntax DellRemoteAccessHostCapabilities (See Table 20-8) Access Read-only Remote Access Host Settings Name remoteAccessHostSettings Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.17 Description Defines the host settings of the remote access hardware. Syntax DellRemoteAccessHostSettings (See Table 20-9) Access Read-write Remote Access Out-of-Band Simple Network Management Protocol (SNMP) Capabilities Name remoteAccessOutOfBandSNMPCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.18 Description Defines the out-of-band SNMP capabilities of the remote access hardware. Syntax DellRemoteAccessOutOfBandSNMPCapabilities (See Table 20-10) Access Read-only 484 Remote Access Group Remote Access Out-of-Band SNMP Settings Name remoteAccessOutOfBandSNMPSettings Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.19 Description Defines the out-of-band SNMP settings of the remote access hardware. Syntax DellRemoteAccessOutOfBandSNMPSettings (See Table 20-11) Access Read-write Remote Access Simple Mail Transfer Protocol (SMTP) Server Internet Protocol (IP) Address Name remoteAccessSMTPServerIPAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.20 Description Defines the IP address for the SMTP server used by the remote access hardware. Syntax IpAddress Access Read-write Remote Access Floppy Trivial File Transfer Protocol (TFTP) IP Address Name remoteAccessFloppyTFTPIPAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.21 Description Defines the IP address of the TFTP server providing the operating system image used by the remote access hardware. Syntax IpAddress Access Read-write Remote Access Floppy TFTP Path Name Name remoteAccessFloppyTFTPPathName Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.22 Description Defines the file name of the operating system image obtained from the TFTP server used by the remote access hardware. Syntax DisplayString (SIZE (0..255)) Access Read-write Remote Access Group 485 Remote Access Firmware Update IP Address Name remoteAccessFirmwareUpdateIPAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.23 Description Defines the IP address of the update server providing the firmware image used by the remote access hardware. Syntax IpAddress Access Read-write Remote Access Firmware Update Path Name Name remoteAccessFirmwareUpdatePathName Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.24 Description Defines the file name of the firmware image obtained from the update server used by the remote access hardware. Syntax DisplayString (SIZE (0..255)) Access Read-write Remote Access Network Interface Controller (NIC) Static IP Address Name remoteAccessNICStaticIPAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.25 Description Defines the static IP address to be used by the integrated NIC provided by the remote access hardware. Syntax IpAddress Access Read-write Remote Access NIC Static Netmask Address Name remoteAccessNICStaticNetmaskAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.26 Description Defines the netmask for the static IP address to be used by the integrated NIC provided by the remote access hardware. Syntax IpAddress Access Read-write 486 Remote Access Group Remote Access NIC Static Gateway Address Name remoteAccessNICStaticGatewayAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.27 Description Defines the IP address for the gateway associated with the static IP address to be used by the integrated NIC provided by the remote access hardware. Syntax IpAddress Access Read-write Remote Access Personal Computer Memory Card International Association (PCMCIA) Info Name Name remoteAccessPCMCIAInfoName Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.28 Description Defines the information for the PCMCIA device used by the remote access hardware. Syntax DisplayString (SIZE (0..63)) Access Read-only Remote Access Miscellaneous Information Name Name remoteAccessMiscInfoName Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.29 Description Defines the miscellaneous information for the remote access hardware. Syntax DisplayString (SIZE (0..63)) Access Read-write Remote Access Group 487 Remote Access NIC Current IP Address Name remoteAccessNICCurrentIPAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.30 Description Defines the IP address currently being used by the integrated NIC provided by the remote access hardware. Syntax IpAddress Access Read-only Remote Access NIC Current Netmask Address Name remoteAccessNICCurrentNetmaskAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.31 Description Defines the netmask currently being used by the integrated NIC provided by the remote access hardware. Syntax IpAddress Access Read-only Remote Access NIC Current Gateway Address Name remoteAccessNICCurrentGatewayAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.32 Description Defines the IP address for the gateway currently being used by the integrated NIC provided by the remote access hardware. Syntax IpAddress Access Read-only 488 Remote Access Group Remote Access NIC Current Information From Dynamic Host Configuration Protocol (DHCP) Name remoteAccessNICCurrentInfoFromDHCP Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.33 Description Defines whether DHCP was used to obtain the NIC information currently being used by the integrated NIC provided by the remote access hardware. Syntax DellBoolean Access Read-only Remote User Administration Table Name remoteUserAdminTable Object ID 1.3.6.1.4.1.674.10892.1.1700.20 Description Defines the Remote Access User Administration Table. Syntax SEQUENCE OF RemoteUserAdminTableEntry Access Not accessible Remote User Admin Table Entry Name remoteUserAdminTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1 Description Defines the Remote Access User Administration Table entry. Syntax RemoteUserAdminTableEntry Access Not accessible Index remoteUserAdminChassisIndex, remoteUserAdminAdapterIndex, remoteUserAdminUserIndex Remote Access Group 489 Remote User Admin Chassis Index Name remoteUserAdminChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.1 Description Defines the index (one-based) of the chassis containing the remote access hardware. Syntax DellObjectRange Access Read-only Remote User Admin Adapter Index Name remoteUserAdminAdapterIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.2 Description Defines the index (one-based) of the remote access hardware used by this remote access user. Syntax DellObjectRange Access Read-only Remote User Admin User Index Name remoteUserAdminUserIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.3 Description Defines the index (one-based) of this remote access user. Syntax DellObjectRange Access Read-only Remote User Admin State Capabilities Name remoteUserAdminStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.4 Description Defines the state capabilities for this remote access user. Syntax DellRemoteUserAdminStateCapabilities (See Table 20-12) Access Read-only 490 Remote Access Group Remote User Admin State Settings Name remoteUserAdminStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.5 Description Defines the state settings for this remote access user. Syntax DellRemoteUserAdminStateSettings (See Table 20-13) Access Read-write Remote User Admin Status Name remoteUserAdminStatus Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.6 Description Defines the status for this remote access user. Syntax DellStatus Access Read-only Remote User Admin User Name Name remoteUserAdminUserName Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.7 Description Defines the user name for this remote access user. Syntax DisplayString (SIZE (0..19)) Access Read-write Remote User Admin User Password Name Name remoteUserAdminUserPasswordName Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.8 Description Defines the password for this remote access user. Syntax DisplayString (SIZE (0..255)) Access Read-write Remote Access Group 491 Remote User Admin User Privilege Name remoteUserAdminUserPrivilege Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.9 Description Defines the privileges for this remote access user. Syntax DisplayString (SIZE (0..31)) Access Read-write Remote User Admin User Privilege Capabilities Name remoteUserAdminUserPrivilegeCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.10 Description Defines the privilege capabilities for this remote access user. Syntax DisplayString (SIZE (0..31)) Access Read-only Remote User Admin Alert Filter DRS Events Mask Name remoteUserAdminAlertFilterDrsEventsMask Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.11 Description Defines the DRS events filter mask for this remote access user. Syntax DellUnsigned32BitRange Access Read-write Remote User Admin Alert Filter System Events Mask Name remoteUserAdminAlertFilterSysEventsMask Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.12 Description Defines the system events filter mask for this remote access user. Syntax DellUnsigned32BitRange Access Read-write 492 Remote Access Group Remote User Admin Alert Filter DRS Capabilities Name remoteUserAdminAlertFilterDrsCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.13 Description Defines the DRS events filter capabilities for this remote access user. Syntax DellUnsigned32BitRange Access Read-only Remote User Admin Alert Filter System Capabilities Name remoteUserAdminAlertFilterSysCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.14 Description Defines the system events filter capabilities for this remote access user. Syntax DellUnsigned32BitRange Access Read-only Remote User Admin Pager Numeric Number Name Name remoteUserAdminPagerNumericNumberName Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.15 Description Defines the numeric pager number for this remote access user. Syntax DisplayString (SIZE (0..95)) Access Read-write Remote User Admin Pager Numeric Message Name Name remoteUserAdminPagerNumericMessageName Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.16 Description Defines the message to send to the numeric pager for this remote access user. Syntax DisplayString (SIZE (0..31)) Access Read-write Remote Access Group 493 Remote User Admin Pager Numeric Hang-up Delay Name remoteUserAdminPagerNumericHangupDelay Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.17 Description Defines the numeric pager hang-up delay for this remote access user. Syntax DellUnsigned32BitRange Access Read-write Remote User Admin Pager Alpha Phone Number Name Name remoteUserAdminPagerAlphaPhoneNumberName Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.18 Description Defines the alphanumeric pager phone number for this remote access user. Syntax DisplayString (SIZE (0..95)) Access Read-write Remote User Admin Pager Alpha Protocol Name remoteUserAdminPagerAlphaProtocol Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.19 Description Defines the protocol used by the alphanumeric pager provider for this remote access user. Syntax DellRemoteUserAdminAlphaProtocolType (See Table 20-16) Access Read-write Remote User Admin Pager Alpha Baud Rate Name remoteUserAdminPagerAlphaBaudRate Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.20 Description Defines the baud rate used by the alphanumeric pager provider for this remote access user. Syntax DellRemoteUserAdminAlphaBaudType (See Table 20-17) Access Read-write 494 Remote Access Group Remote User Admin Pager Alpha Custom Message Name Name remoteUserAdminPagerAlphaCustomMessageName Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.21 Description Defines the message to be sent to the alphanumeric pager to inform the user of a call by this remote access user. Syntax DisplayString (SIZE (0..31)) Access Read-write Remote User Admin Pager Alpha Modem Connect Time-out Name remoteUserAdminPagerAlphaModemConnectTimeout Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.22 Description Defines the modem connection time-out for the alphanumeric pager for this remote access user. Syntax DellUnsigned32BitRange Access Read-write Remote User Admin Pager Alpha Pager ID Name Name remoteUserAdminPagerAlphaPagerIdName Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.23 Description Defines the ID to be sent to the alphanumeric pager to inform the user of a call by this remote access user. Syntax DisplayString (SIZE (0..31)) Access Read-write Remote User Admin Pager Alpha Password Name Name remoteUserAdminPagerAlphaPasswordName Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.24 Description Defines the password for the alphanumeric pager for this remote access user. Syntax DisplayString (SIZE (0..31)) Access Read-write Remote Access Group 495 Remote User Admin Pager Modem Init String Name Name remoteUserAdminPagerModemInitStringName Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.25 Description Defines the initialization string to be sent to the pager modem for this remote access user. Syntax DisplayString (SIZE (0..31)) Access Read-write Remote User Admin Pager Modem Port Name remoteUserAdminPagerModemPort Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.26 Description Defines the port for the pager modem for this remote access user. Syntax DellUnsigned32BitRange Access Read-write Remote User Admin E-Mail Address Name Name remoteUserAdminEmailAddressName Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.27 Description Defines the e-mail address for this remote access user. Syntax DisplayString (SIZE (0..63)) Access Read-write Remote User Admin E-Mail Custom Message Name Name remoteUserAdminEmailCustomMessageName Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.28 Description Defines the e-mail message to send to this remote access user. Syntax DisplayString (SIZE (0..31)) Access Read-write 496 Remote Access Group Remote User Admin Control Capabilities Name remoteUserAdminControlCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.29 Description Defines the control capabilities for this remote access user. Syntax DellRemoteUserAdminControlCapabilities (See Table 20-14 on page 519) Access Read-only Remote User Admin Control Settings Name remoteUserAdminControlSettings Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.30 Description Defines the control settings for this remote access user. Syntax DellRemoteUserAdminControlSettings (See Table 20-15) Access Read-write Remote User Admin User Type Name remoteUserAdminUserType Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.31 Description Defines the type of user for this remote access user. Syntax DellUnsigned8BitRange Access Read-write Remote SNMP Trap Table Name remoteSNMPTrapTable Object ID 1.3.6.1.4.1.674.10892.1.1700.30 Description Defines the Remote Access SNMP Trap Destination Table. Syntax SEQUENCE OF RemoteSNMPTrapTableEntry Access Not accessible Remote Access Group 497 Remote SNMP Trap Table Entry Name remoteSNMPTrapTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1700.30.1 Description Defines the Remote Access SNMP Trap Destination Table entry. Syntax RemoteSNMPTrapTableEntry Access Not accessible Index remoteSNMPTrapChassisIndex, remoteSNMPTrapAdapterIndex, remoteSNMPTrapIndex Remote SNMP Trap Chassis Index Name remoteSNMPTrapChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.30.1.1 Description Defines the index (one-based) of the chassis containing the remote access hardware. Syntax DellObjectRange Access Read-only Remote SNMP Trap Adapter Index Name remoteSNMPTrapAdapterIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.30.1.2 Description Defines the index (one-based) of the remote access hardware that uses this SNMP trap destination. Syntax DellObjectRange Access Read-only 498 Remote Access Group Remote SNMP Trap Index Name remoteSNMPTrapIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.30.1.3 Description Defines the index (one-based) of this remote access SNMP trap destination. Syntax DellObjectRange Access Read-only Remote SNMP Trap State Capabilities Name remoteSNMPTrapStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.30.1.4 Description Defines the state capabilities of this remote access SNMP trap destination. Syntax DellRemoteSNMPTrapStateCapabilities (See Table 20-18) Access Read-only Remote SNMP Trap State Settings Name remoteSNMPTrapStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1700.30.1.5 Description Defines the state settings of this remote access SNMP trap destination. Syntax DellRemoteSNMPTrapStateSettings (See Table 20-19) Access Read-write Remote SNMP Trap Status Name remoteSNMPTrapStatus Object ID 1.3.6.1.4.1.674.10892.1.1700.30.1.6 Description Defines the status of this remote access SNMP trap destination. Syntax DellStatus Access Read-only Remote Access Group 499 Remote SNMP Trap Destination IP Address Name remoteSNMPTrapDestinationIPAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.30.1.7 Description Defines the IP address of this remote access SNMP trap destination. Syntax IpAddress Access Read-write Remote SNMP Trap SNMP Community Name Name remoteSNMPTrapSNMPCommunityName Object ID 1.3.6.1.4.1.674.10892.1.1700.30.1.8 Description Defines the community for traps sent to this remote access SNMP trap destination. Syntax DisplayString (SIZE (0..31)) Access Read-write Remote SNMP Trap Filter DRS Events Mask Name remoteSNMPTrapFilterDrsEventsMask Object ID 1.3.6.1.4.1.674.10892.1.1700.30.1.9 Description Defines the DRS events filter mask for this remote access SNMP trap destination. Syntax DellUnsigned32BitRange Access Read-write Remote SNMP Trap Filter System Events Mask Name remoteSNMPTrapFilterSysEventsMask Object ID 1.3.6.1.4.1.674.10892.1.1700.30.1.10 Description Defines the system events filter mask for this remote access SNMP trap destination. Syntax DellUnsigned32BitRange Access Read-write 500 Remote Access Group Remote SNMP Trap Filter DRS Capabilities Name remoteSNMPTrapFilterDrsCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.30.1.11 Description Defines the DRS events filter capabilities for this remote access SNMP trap destination. Syntax DellUnsigned32BitRange Access Read-only Remote SNMP Trap Filter System Capabilities Name remoteSNMPTrapFilterSysCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.30.1.12 Description Defines the system events filter capabilities of this remote access SNMP trap destination. Syntax DellUnsigned32BitRange Access Read-only Remote SNMP Trap Control Capabilities Name remoteSNMPTrapControlCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.30.1.13 Description Defines the control capabilities of this remote access SNMP trap destination. Syntax DellRemoteSNMPTrapControlCapabilities (See Table 20-20) Access Read-only Remote SNMP Trap Control Settings Name remoteSNMPTrapControlSettings Object ID 1.3.6.1.4.1.674.10892.1.1700.30.1.14 Description Defines the control settings of this remote access SNMP trap destination. Syntax DellRemoteSNMPTrapControlSettings (See Table 20-21) Access Read-write Remote Access Group 501 Remote Dial-Up Table Name remoteDialUpTable Object ID 1.3.6.1.4.1.674.10892.1.1700.40 Description Defines the Remote Access Dial-Up Table. Syntax SEQUENCE OF RemoteDialUpTableEntry Access Not accessible Remote Dial-Up Table Entry Name remoteDialUpTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1700.40.1 Description Defines the Remote Access Dial-Up Table entry. Syntax RemoteDialUpTableEntry Access Not accessible Index remoteDialUpChassisIndex, remoteDialUpAdapterIndex, remoteDialUpIndex Remote Dial-Up Chassis Index Name remoteDialUpChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.40.1.1 Description Defines the index (one-based) of the chassis containing the remote access hardware. Syntax DellObjectRange Access Read-only 502 Remote Access Group Remote Dial-Up Adapter Index Name remoteDialUpAdapterIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.40.1.2 Description Defines the index (one-based) of the remote access hardware that supports this remote access dial-up functionality. Syntax DellObjectRange Access Read-only Remote Dial-Up Index Name remoteDialUpIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.40.1.3 Description Defines the index (one-based) of this remote access dial-up functionality. Syntax DellObjectRange Access Read-only Remote Dial-Up State Capabilities Name remoteDialUpStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.40.1.4 Description Defines the state capabilities of this remote access dial-up functionality. Syntax DellRemoteDialUpStateCapabilities (See Table 20-22) Access Read-only Remote Dial-Up State Settings Name remoteDialUpStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1700.40.1.5 Description Defines the state settings of this remote access dial-up functionality. Syntax DellRemoteDialUpStateSettings (See Table 20-23) Access Read-write Remote Access Group 503 Remote Dial-Up Status Name remoteDialUpStatus Object ID 1.3.6.1.4.1.674.10892.1.1700.40.1.6 Description Defines the status of this remote access dial-up functionality. Syntax DellStatus Access Read-only Remote Dial-Up PPP Dial-In Base IP Address Name remoteDialUpPPPDialInBaseIPAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.40.1.7 Description Defines the base IP address of the PPP server for this remote access dial-up functionality. Syntax IpAddress Access Read-write Remote Dial-Up PPP Dial-In Idle Time-out Name remoteDialUpPPPDialInIdleTimeout Object ID 1.3.6.1.4.1.674.10892.1.1700.40.1.8 Description Defines the PPP idle time-out value in seconds for this remote access dial-up functionality. Syntax DellUnsigned32BitRange Access Read-write Remote Dial-Up PPP Dial-In Maximum Connection Time-out Name remoteDialUpPPPDialInMaxConnectTimeout Object ID 1.3.6.1.4.1.674.10892.1.1700.40.1.9 Description Defines the PPP connect time-out value in seconds for this remote access dial-up functionality. Syntax DellUnsigned32BitRange Access Read-write 504 Remote Access Group Remote Dial-Up Dial-Out Modem Connect Time-out Name remoteDialUpDialOutModemConnectTimeout Object ID 1.3.6.1.4.1.674.10892.1.1700.40.1.10 Description Defines the modem dial-out time-out value in seconds for this remote access dial-up functionality. Syntax DellUnsigned32BitRange Access Read-write Remote Dial-Up Modem Dial Type Name remoteDialUpModemDialType Object ID 1.3.6.1.4.1.674.10892.1.1700.40.1.11 Description Defines the dial type for the modem used by this remote access dial-up functionality. Syntax DellRemoteDialUpModemDialType (See Table 20-24) Access Read-write Remote Dial-Up Modem Init String Name Name remoteDialUpModemInitStringName Object ID 1.3.6.1.4.1.674.10892.1.1700.40.1.12 Description Defines the initialization string to be sent to the modem for this remote access dial-up functionality. Syntax DisplayString (SIZE (0..63)) Access Read-write Remote Dial-Up Modem Baud Rate Name remoteDialUpModemBaudRate Object ID 1.3.6.1.4.1.674.10892.1.1700.40.1.13 Description Defines the baud rate for the modem used by this remote access dial-up functionality. Syntax DellUnsigned32BitRange Access Read-write Remote Access Group 505 Remote Dial-Up Modem Port Name remoteDialUpModemPort Object ID 1.3.6.1.4.1.674.10892.1.1700.40.1.14 Description Defines the port for the modem used by this remote access dialup functionality. Syntax DellUnsigned32BitRange Access Read-write Remote User Dial-In Configuration Table Name remoteUserDialInCfgTable Object ID 1.3.6.1.4.1.674.10892.1.1700.50 Description Defines the Remote Access User Dial-In Configuration Table. Syntax SEQUENCE OF RemoteUserDialInCfgTableEntry Access Not accessible Remote User Dial-In Configuration Table Entry Name remoteUserDialInCfgTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1700.50.1 Description Defines the Remote Access User Dial-In Configuration Table entry. Syntax RemoteUserDialInCfgTableEntry Access Not accessible Index remoteUserDialInCfgChassisIndex, remoteUserDialInCfgAdapterIndex, remoteUserDialInCfgUserIndex 506 Remote Access Group Remote User Dial-In Configuration Chassis Index Name remoteUserDialInCfgChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.50.1.1 Description Defines the index (one-based) of the chassis containing the remote access hardware. Syntax DellObjectRange Access Read-only Remote User Dial-In Configuration Adapter Index Name remoteUserDialInCfgAdapterIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.50.1.2 Description Defines the index (one-based) of the remote access hardware that supports this remote access dial-in user. Syntax DellObjectRange Access Read-only Remote User Dial-In Configuration User Index Name remoteUserDialInCfgUserIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.50.1.3 Description Defines the index (one-based) of this remote access dial-in user. Syntax DellObjectRange Access Read-only Remote User Dial-In Configuration State Capabilities Name remoteUserDialInCfgStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.50.1.4 Description Defines the state capabilities of this remote access dial-in user. Syntax DellRemoteUserDialInStateCapabilities (See Table 20-25) Access Read-only Remote Access Group 507 Remote User Dial-In Configuration State Settings Name remoteUserDialInCfgStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1700.50.1.5 Description Defines the state settings of this remote access dial-in user. Syntax DellRemoteUserDialInStateSettings (See Table 20-26) Access Read-write Remote User Dial-In Configuration Status Name remoteUserDialInCfgStatus Object ID 1.3.6.1.4.1.674.10892.1.1700.50.1.6 Description Defines the status of this remote access dial-in user. Syntax DellStatus Access Read-only Remote User Dial-In Configuration PPP Username Name remoteUserDialInCfgPPPUserName Object ID 1.3.6.1.4.1.674.10892.1.1700.50.1.7 Description Defines the PPP user name of this remote access dial-in user. Syntax DisplayString (SIZE (0..15)) Access Read-write Remote User Dial-In Configuration PPP User Password Name Name remoteUserDialInCfgPPPUserPasswordName Object ID 1.3.6.1.4.1.674.10892.1.1700.50.1.8 Description Defines the PPP password of this remote access dial-in user. Syntax DisplayString (SIZE (0..15)) Access Read-write 508 Remote Access Group Remote User Dial-In Configuration Callback Phone Number Name Name remoteUserDialInCfgCallbackPhoneNumberName Object ID 1.3.6.1.4.1.674.10892.1.1700.50.1.9 Description Defines the callback phone number for this remote access dial-in user. Syntax DisplayString (SIZE (0..95)) Access Read-write Remote Dial-Out Table Name remoteDialOutTable Object ID 1.3.6.1.4.1.674.10892.1.1700.60 Description Defines the Remote Access Dial-Out Table. Syntax SEQUENCE of RemoteDialOutTableEntry Access Not accessible Remote Dial-Out Table Entry Name remoteDialOutTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1700.60.1 Description Defines the Remote Access Dial-Out Table entry. Syntax RemoteDialOutTableEntry Access Not accessible Index remoteDialOutChassisIndex, remoteDialOutAdapterIndex, remoteDialOutDialOutIndex Remote Dial-Out Chassis Index Name remoteDialOutChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.60.1.1 Description Defines the index (one-based) of the chassis containing the remote access hardware. Syntax DellObjectRange Access Read-only Remote Access Group 509 Remote Dial-Out Adapter Index Name remoteDialOutAdapterIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.60.1.2 Description Defines the index (one-based) of the remote access hardware that supports this remote access dial-out functionality. Syntax DellObjectRange Access Read-only Remote Dial-Out Dial-Out Index Name remoteDialOutDialOutIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.60.1.3 Description Defines the index (one-based) of this remote access dial-out functionality. Syntax DellObjectRange Access Read-only Remote Dial-Out State Capabilities Name remoteDialOutStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.60.1.4 Description Defines the state capabilities of this remote access dial-out functionality. Syntax DellRemoteDialOutStateCapabilities (See Table 20-27) Access Read-only Remote Dial-Out State Settings Name remoteDialOutStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1700.60.1.5 Description Defines the state settings of this remote access dial-out functionality. Syntax DellRemoteDialOutStateSettings (See Table 20-28) Access Read-write 510 Remote Access Group Remote Dial-Out Status Name remoteDialOutStatus Object ID 1.3.6.1.4.1.674.10892.1.1700.60.1.6 Description Defines the status of this remote access dial-out functionality. Syntax DellStatus Access Read-only Remote Dial-Out IP Address Name remoteDialOutIPAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.60.1.7 Description Defines the IP address for this remote access dial-out destination. Syntax IpAddress Access Read-write Remote Dial-Out Phone Number Name Name remoteDialOutPhoneNumberName Object ID 1.3.6.1.4.1.674.10892.1.1700.60.1.8 Description Defines the phone number for this remote access dial-out destination. Syntax DisplayString (SIZE (0..95)) Access Read-write Remote Dial-Out PPP Username Name remoteDialOutPPPUserName Object ID 1.3.6.1.4.1.674.10892.1.1700.60.1.9 Description Defines the PPP username for this remote access dial-out destination. Syntax DisplayString (SIZE (0..31)) Access Read-write Remote Access Group 511 Remote Dial-Out PPP Password Name Name remoteDialOutPPPPasswordName Object ID 1.3.6.1.4.1.674.10892.1.1700.60.1.10 Description Defines the PPP password for this remote access dial-out destination. Syntax DisplayString (SIZE (0..31)) Access Read-write Remote Access Variable Values This section includes definitions for server administrator-specific variable values used in this section. Table 20-1. Remote Access Type Variable Name: DellRemoteAccessType Data Type: Integer Possible Data Values Meaning of Data Value remoteAccessTypeIsOther(1) The remote access type is not one of the following: remoteAccessTypeIsUnknown(2) The remote access type is unknown. remoteAccessTypeIsDRACIII(3) The remote access type is DRAC III. remoteAccessTypeIsERA(4) The remote access type is ERA. Table 20-2. Remote Access Control Capabilities Variable Name: DellRemoteAccessControlCapabilities Data Type: Integer Possible Data Values Meaning of Data Value none(0) The remote access hardware has no control capabilities. unknownCapabilities(1) The remote access hardware control capabilities are unknown. 512 Remote Access Group Table 20-2. Remote Access Control Capabilities (continued) Variable Name: DellRemoteAccessControlCapabilities Data Type: Integer Possible Data Values Meaning of Data Value logResetCapable(2) The remote access hardware can reset its integrated logs. hardResetCapable(4) The remote access hardware can perform a hard reset. softResetCapable(8) The remote access hardware can perform a soft reset. gracefulResetCapable(16) The remote access hardware can gracefully shut down and perform a soft reset. defaultConfigResetCapable(32) The remote access hardware can reset to its default settings. shutdownCapable(64) Table 20-3. The remote access hardware can shut down. Remote Access Control Settings Variable Name: DellRemoteAccessControlSettings Data Type: Integer Possible Data Values Meaning of Data Value none(0) The remote access hardware has no control settings. unknown(1) The remote access hardware control settings are unknown. logReset(2) The remote access hardware resets its integrated logs. hardReset(4) The remote access hardware performs a hard reset. softReset(8) The remote access hardware performs a soft reset. gracefulReset(16) The remote access hardware shuts down and perform a soft reset. Remote Access Group 513 Table 20-3. Remote Access Control Settings (continued) Variable Name: DellRemoteAccessControlSettings Data Type: Integer Possible Data Values Meaning of Data Value defaultConfigReset(32) The remote access hardware resets to its default settings. shutdown(64) The remote access hardware shuts down. Table 20-4. Remote Access Monitor Capabilities Variable Name: DellRemoteAccessMonitorCapabilities Data Type: Integer Possible Data Values Meaning of Data Value none(0) The remote access hardware has no monitor capabilities. unknownCapabilities(1) The remote access hardware monitor capabilities are unknown. extPwrSupplyMonitorIfConn The remote access hardware can be set to ectedCapable(2) monitor the external power supply, if connected. extPwrSupplyMonitorAlways The remote access hardware can be set to EnabledCapable(4) always monitor the external power supply. 514 Remote Access Group Table 20-5. Remote Access Monitor Settings Variable Name: DellRemoteAccessMonitorSettings Data Type: Integer Possible Data Values Meaning of Data Value none(0) The remote access hardware has no monitor settings. unknown(1) The remote access hardware monitor settings are unknown. extPwrSupplyMonitorIfConn The remote access hardware monitors the ectedEnabled(2) external power supply, if connected. extPwrSupplyMonitorAlways The remote access hardware always monitors EnabledEnabled(4) the external power supply. Table 20-6. Remote Access Local Area Network (LAN) Capabilities Variable Name: DellRemoteAccessLANCapabilities Data Type: Integer Possible Data Values Meaning of Data Value none(0) The remote access hardware has no LAN capabilities. unknownCapabilities(1) The remote access hardware LAN capabilities are unknown. nicCapable(2) The remote access hardware has a network interface controller (NIC). nicDHCPCapable(4) The remote access hardware NIC can use DHCP to obtain an IP address. Remote Access Group 515 Table 20-7. Remote Access LAN Settings Variable Name: DellRemoteAccessLANSettings Data Type: Integer Possible Data Values Meaning of Data Value none(0) The remote access hardware has no LAN settings. unknown(1) The remote access hardware LAN settings are unknown. nicEnabled(2) The remote access hardware NIC is enabled. nicDHCPEnabled(4) The remote access hardware NIC uses DHCP to obtain an IP address. Table 20-8. Remote Access Host Capabilities Variable Name: DellRemoteAccessHostCapabilities Data Type: Integer Possible Data Values Meaning of Data Value none(0) The remote access hardware has no host capabilities. unknownCapabilities(1) The remote access hardware host capabilities are unknown. smtpEmailCapable(2) The remote access hardware supports sending e-mail using SMTP. tftpRemoteFloppyCapable(4) The remote access hardware supports remote floppy boot using a TFTP server. tftpRemoteFwUpdateCapable(8) The remote access hardware supports remote firmware update using a TFTP server. 516 Remote Access Group Table 20-9. Remote Access Host Settings Variable Name: DellRemoteAccessHostSettings Data Type: Integer Possible Data Values Meaning of Data Value none(0) The remote access hardware has no host settings. unknown(1) The remote access hardware host settings are unknown. smtpEmailEnabled(2) The remote access hardware SMTP client is enabled for sending e-mail. tftpRemoteFloppyEnabled(4) The remote access hardware TFTP client is enabled for remote floppy boot. tftpRemoteFwUpdateEnabled(8) The remote access hardware TFTP client is enabled for remote firmware update. Table 20-10. Remote Access Out-Of-Band Simple Network Management Protocol (SNMP) Capabilities Variable Name: DellRemoteAccessOutOfBandSNMPCapabilities Data Type: Integer Possible Data Values Meaning of Data Value none(0) The remote access hardware has no out-of-band SNMP capabilities. unknownCapabilities(1) The remote access hardware out-of-band SNMP capabilities are unknown. oobSNMPAgentCapable(2) The remote access hardware has an out-of-band SNMP agent. oobSNMPTrapsCapable(4) The remote access hardware can send out-of-band SNMP traps. Remote Access Group 517 Table 20-11. Remote Access Out-Of-Band Simple Network Management Protocol (SNMP) Settings Variable Name: DellRemoteAccessOutOfBandSNMPSettings Data Type: Integer Possible Data Values Meaning of Data Value none(0) The remote access hardware has no out-of-band SNMP settings. unknown(1) The remote access hardware out-of-band SNMP settings are unknown. oobSNMPAgentEnabled(2) The remote access hardware out-of-band SNMP agent is enabled. oobSNMPTrapsEnabled(4) The remote access hardware sends out-of-band SNMP traps. Table 20-12. Remote User Admin State Capabilities Variable Name: DellRemoteUserAdminStateCapabilities Data Type: Integer Possible Data Values Meaning of Data Value none(0) The admin user has no state capabilities. unknownCapabilities(1) The admin user state capabilities are unknown. enableCapable(2) The admin user can be disabled or enabled. notReadyCapable(4) The admin user can be in the not ready state. numericPagerCapable(8) The admin user supports numeric paging. alphaPagerCapable(16) The admin user supports alphanumeric paging. emailCapable(32) The admin user supports e-mail. privilegeCapable(64) The admin user supports user privileges configuration. 518 Remote Access Group Table 20-13. Remote User Admin State Settings Variable Name: DellRemoteUserAdminStateSettings Data Type: Integer Possible Data Values Meaning of Data Value none(0) The admin user has no state settings. unknown(1) The admin user state settings are unknown. enabled(2) The admin user is enabled. notReady(4) The admin user is in the not ready state. numericPagerEnabled(8) Numeric paging is enabled for the admin user. alphaPagerEnabled(16) Alphanumeric paging is enabled for the admin user. emailEnabled(32) E-mail is enabled for the admin user. Table 20-14. Remote User Admin Control Capabilities Variable Name: DellRemoteUserAdminControlCapabilities Data Type: Integer Possible Data Values Meaning of Data Value none(0) The admin user has no control capabilities. unknownCapabilities(1) The admin user control capabilities are unknown. numericPagerTestCapable(2) The admin user can support sending a test numeric page. alphaPagerTestCapable(4) The admin user can support sending a test alphanumeric page. emailTestCapable(8) The admin user can support sending a test e-mail. Remote Access Group 519 Table 20-15. Remote User Admin Control Settings Variable Name: DellRemoteUserAdminControlSettings Data Type: Integer Possible Data Values Meaning of Data Value none(0) The admin user has no control settings. unknown(1) The admin user control settings are unknown. numericPagerTest(2) A numeric pager test is performed for the admin user. alphaPagerTest(4) An alphanumeric pager test is performed for the admin user. emailTest(8) An e-mail test is performed for the admin user. Table 20-16. Remote User Admin Alpha Protocol Type Variable Name: DellRemoteUserAdminAlphaProtocolType Data Type: Integer Possible Data Values Meaning of Data Value other(1) The remote user admin alpha protocol type is not one of the following: unknown(2) The remote user admin alpha protocol type is unknown. alpha7E0(3) The remote user admin alpha protocol type is 7E0. alpha8N1(4) The remote user admin alpha protocol type is 8N1. 520 Remote Access Group Table 20-17. Remote User Admin Alpha Baud Type Variable Name: DellRemoteUserAdminAlphaBaudType Data Type: Integer Possible Data Values Meaning of Data Value other(1) The remote user alphanumeric baud rate is not one of the following: unknown(2) The remote user alphanumeric baud rate is unknown. alphaBaud300(3) The remote user alphanumeric baud rate is 300. alphaBaud1200(4) The remote user alphanumeric baud rate is 1200. Table 20-18. Remote SNMP Trap State Capabilities Variable Name: DellRemoteSNMPTrapStateCapabilities Data Type: Integer Possible Data Values Meaning of Data Value none(0) The SNMP trap destination has no state capabilities. unknownCapabilities The SNMP trap destination state capabilities (1) are unknown. enableCapable(2) The SNMP trap destination can be disabled or enabled. notReadyCapable(4) The SNMP trap destination can be in the not ready state. Table 20-19. Remote SNMP Trap State Settings Variable Name: DellRemoteSNMPTrapStateSettings Data Type: Integer Possible Data Values Meaning of Data Value none(0) The SNMP trap destination has no state settings. unknown(1) The SNMP trap destination state settings are unknown. enabled(2) The SNMP trap destination is enabled. notReady(4) The SNMP trap destination is in the not ready state. Remote Access Group 521 Table 20-20. Remote SNMP Trap Control Capabilities Variable Name: DellRemoteSNMPTrapControlCapabilities Data Type: Integer Possible Data Values Meaning of Data Value none(0) The SNMP trap destination has no control capabilities. unknownCapabilities The SNMP trap destination control capabilities are (1) unknown. trapTestCapable(2) A SNMP trap test can be performed for the SNMP trap destination. Table 20-21. Remote SNMP Trap Control Settings Variable Name: DellRemoteSNMPTrapControlSettings Data Type: Integer Possible Data Values Meaning of Data Value none(0) The SNMP trap destination has no control settings. unknown(1) The SNMP trap destination control settings are unknown. trapTestCapable(2) A SNMP trap test is performed for the SNMP trap destination. Table 20-22. Remote Dial-Up State Capabilities Variable Name: DellRemoteDialUpStateCapabilities Data Type: Integer Possible Data Values Meaning of Data Value none(0) The dial-up functionality has no state capabilities. unknownCapabilities(1) The dial-up functionality state capabilities are unknown. enableCapable(2) The dial-up functionality can be disabled or enabled. 522 Remote Access Group Table 20-22. Remote Dial-Up State Capabilities (continued) Variable Name: DellRemoteDialUpStateCapabilities Data Type: Integer Possible Data Values Meaning of Data Value notReadyCapable(4) The dial-up functionality can be in the not ready state. dialInCapable(8) The dial-up functionality can support the dial-in feature. dialOutCapable(16) The dial-up functionality can support the dial-out feature. dialInDHCPCapable(32) The dial-up functionality can support using DHCP to obtain an IP address for the dial-in feature. dialInAuthAnyCapable(64) The dial-up functionality can support any authentication type (including clear text) for the dial-in feature. dialInAuthEncryptedCapable(128) The dial-up functionality can support encrypted passwords (CHAP) authentication for the dial-in feature. dialInAuthMschapCapable(256) The dial-up functionality can support MSCHAP authentication type for the dial-in feature. Table 20-23. Remote Dial-Up State Settings Variable Name: DellRemoteDialUpStateSettings Data Type: Integer Possible Data Values Meaning of Data Value none(0) The dial-up functionality has no state settings. unknown(1) The dial-up functionality state settings are unknown. enabled(2) The dial-up functionality is enabled. notReadyCapable(4) The dial-up functionality is in the not ready state. dialInEnabled(8) The dial-up functionality dial-in feature is enabled. dialOutEnabled(16) The dial-up functionality dial-out feature is enabled. Remote Access Group 523 Table 20-23. Remote Dial-Up State Settings (continued) Variable Name: DellRemoteDialUpStateSettings Data Type: Integer Possible Data Values Meaning of Data Value dialInDHCPEnabled(32) The dial-up functionality uses DHCP to obtain an IP address for the dial-in feature. dialInAuthAnyEnabled The dial-up functionality accepts any authentication (64) type (including clear text) for the dial-in feature. dialInAuthEncrypted The dial-up functionality uses only encrypted Enabled(128) passwords (CHAP) authentication type for the dialin feature. dialInAuthMschapEnab The dial-up functionality uses only MSCHAP led(256) authentication type for the dial-in feature. Table 20-24. Remote Dial-Up Modem Dial Type Variable Name: DellRemoteDialUpModemDialType Data Type: Integer Possible Data Values Meaning of Data Value remoteDialUpIsOther(1) The remote dial type is not one of the following: remoteDialUpIsUnknown(2) The remote dial type is unknown. remoteDialUpIsTone(3) The remote dial type is tone. remoteDialUpIsPulse(4) The remote dial type is pulse. 524 Remote Access Group Table 20-25. Remote User Dial-In State Capabilities Variable Name: DellRemoteUserDialInStateCapabilities Data Type: Integer Possible Data Values Meaning of Data Value none(0) The dial-in user has no state capabilities. unknownCapabilities(1) The dial-in user state capabilities are unknown. enableCapable(2) The dial-in user can be disabled or enabled. notReadyCapable(4) The dial-in user can be in the not ready state. dialInCallbackPresetNumber The dial-in user can support callback Capable(8) using a preset number. dialInCallbackUserSpecified The dial-in user can support callback Capable(16) using a user-specified number. Table 20-26. Remote User Dial-In State Settings Variable Name: DellRemoteUserDialInStateSettings Data Type: Integer Possible Data Values Meaning of Data Value none(0) The dial-in user has no state settings. unknown(1) The dial-in user state settings are unknown. enabled(2) The dial-in user is enabled. notReady(4) The dial-in user is in the not ready state. dialInCallbackPresetNumber Callback using a preset number is Enabled(8) enabled for the dial-in user. dialInCallbackUserSpecified Callback using a user-specified number is Enabled(16) enabled for the dial-in user. Remote Access Group 525 Table 20-27. Remote Dial-Out State Capabilities Variable Name: DellRemoteDialOutStateCapabilities Data Type: Integer Possible Data Values Meaning of Data Value none(0) The dial-out destination has no state capabilities. unknownCapabilities(1) The dial-out destination state capabilities are unknown. enableCapable(2) The dial-out destination can be disabled or enabled. notReadyCapable(4) The dial-out destination can be in the not ready state. dialOutPPPAuthAnyCapable(8) The dial-out destination can support any authentication type (including clear text) for PPP. dialOutPPPAuthEncryptedCapable(16) The dial-out destination can support encrypted passwords authentication type for PPP. dialOutPPPAuthMschapCapable(32) 526 Remote Access Group The dial-out destination can support MSCHAP authentication type for PPP. Table 20-28. Remote Dial-Out State Settings Variable Name: DellRemoteDialOutStateSettings Data Type: Integer Possible Data Values Meaning of Data Value none(0) The dial-out destination has no state settings. unknown(1) The dial-out destination state settings are unknown. enabled(2) The dial-out destination is disabled or enabled. notReady(4) The dial-out destination is in the not ready state. dialOutPPPAuthAnyEnabled(8) The dial-out destination accepts any authentication type (including clear text) for PPP. dialOutPPPAuthEncryptedEnabled(16) The dial-out destination uses only encrypted passwords authentication type for PPP. dialOutPPPAuthMschapEnabled(32) The dial-out destination uses only MSCHAP authentication type for PPP. Remote Access Group 527 528 Remote Access Group 21 Cluster Group Clustering combines multiple systems in such a way that they provide services a single system cannot. Clustering enhances higher availability, scalability, and management. Higher availability is achieved by using failover clusters, in which resources can automatically move between two or more systems in the event of a failure. Scalability is achieved by balancing the load of an application across several computer systems. Simpler management is achieved by using virtual servers, as opposed to managing each individual computer system. Cluster Group The Cluster Group defines attributes such as the number of systems in the cluster, capabilities of the cluster, type of cluster, and name of the cluster. Cluster Table The following table defines the attributes of the cluster. Name clusterTable Object ID 1.3.6.1.4.1.674.10892.1.1800.10 Description Defines the Cluster Table. Syntax SEQUENCE OF ClusterTableEntry Access Not accessible Cluster Table Entry Name clusterTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1800.10.1 Description Defines the Cluster Table entry. Syntax ClusterTableEntry Access Not accessible Index clusterChassisIndex, clusterIndex Cluster Group 529 Cluster Chassis Index Name clusterChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1800.10.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Cluster Index Name clusterIndex Object ID 1.3.6.1.4.1.674.10892.1.1800.10.1.2 Description Defines the index (one-based) of the cluster. Syntax DellObjectRange Access Read-only Cluster State Capabilities Name clusterStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1800.10.1.3 Description Defines the state capabilities of the cluster. Syntax DellStateCapabilities Access Read-only Cluster State Settings Name clusterStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1800.10.1.4 Description Defines the state settings of the cluster. Syntax DellStateSettings Access Read-write 530 Cluster Group Cluster Status Name clusterStatus Object ID 1.3.6.1.4.1.674.10892.1.1800.10.1.5 Description Defines the status of the cluster. Syntax DellStatus Access Read-only Cluster Type Name clusterType Object ID 1.3.6.1.4.1.674.10892.1.1800.10.1.6 Description Defines the type of the cluster. Syntax DellClusterType Access Read-only Cluster Type Description Name Name clusterTypeDescriptionName Object ID 1.3.6.1.4.1.674.10892.1.1800.10.1.7 Description Defines the description name for the type of the cluster. Syntax DellString Access Read-only Cluster Name Name clusterName Object ID 1.3.6.1.4.1.674.10892.1.1800.10.1.8 Description Defines the name of the cluster. Syntax DellString Access Read-only Cluster Group 531 Cluster Group Variable Values This section includes definitions for Server Administrator-specific variable values used in this section. Table 21-1. Cluster Type Variable Name: DellClusterType Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) The cluster type is unknown. highAvailabilityCluster(2) The cluster type is a high-availability cluster. 532 Cluster Group 22 Baseboard Management Controller Group The Baseboard Management Controller (BMC) monitors the system for critical events by communicating with various sensors on the system board and sends alerts and log events when certain parameters exceed their preset thresholds. The BMC Group provides information about the BMC that may be present in your system. In addition to providing general information about the BMC, this group provides information about the serial and local area network (LAN) interfaces of the BMC. Baseboard Management Controller Group Tables The objects in the BMC group define information about the BMC and the serial and LAN interfaces that can be used to access the BMC remotely to perform management activities. Objects for the serial interface define the serial connection mode, flow control type and bit rate. Objects for the LAN interface define the media access control (MAC) address, internet protocol (IP) address, subnet mask and default gateway. The following MIB tables define the BMC group: • Baseboard Management Controller Table • Baseboard Management Controller Serial Interface Table • Baseboard Management Controller LAN Interface Table Baseboard Management Controller Table Name bmcTable Object ID 1.3.6.1.4.1.674.10892.1.1900.10 Description Defines the Baseboard Management Controller Table. Syntax SEQUENCE OF BmcTableEntry Access Not accessible Baseboard Management Controller Group 533 BMC Table Entry Name bmcTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1 Description Defines the Baseboard Management Controller (BMC) Table Entry. Syntax BmcTableEntry Access Not accessible Index bmcChassisIndex, bmcIndex BMC Chassis Index Name bmcChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.1 Description Defines the index (one-based) of the associated chassis. Syntax DellObjectRange Access Read-only BMC Index Name bmcIndex Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.2 Description Defines the index (one-based) of the BMC. Syntax DellObjectRange Access Read-only BMC State Capabilities Name bmcStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.3 Description Defines the state capabilities of the BMC. Syntax DellStateCapabilities Access Read-only 534 Baseboard Management Controller Group BMC State Settings Name bmcStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.4 Description Defines the state settings of the BMC. Syntax DellStateSettings Access Read-write BMC Status Name bmcStatus Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.5 Description Defines the status of the BMC. Syntax DellStatus Access Read-only BMC Display Name Name bmcDisplayName Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.6 Description Defines the display name of the BMC. Syntax DellString Access Read-only BMC Description Name Name bmcDescriptionName Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.7 Description Defines the description of the BMC. Syntax DisplayString (SIZE (0..255)) Access Read-only Baseboard Management Controller Group 535 BMC IPMI Version Name Name bmcIPMIVersionName Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.8 Description Defines the version of the Intelligent Platform Management Interface (IPMI) specification that the BMC supports. Syntax DellString Access Read-only BMC GUID Name bmcGUID Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.9 Description Defines the Globally Unique ID (GUID) of the BMC. Syntax Octet String (SIZE(16)) Access Read-only BMC Type Name bmcType Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.10 Description Defines the type of the BMC. Syntax DellManagementControllerType Access Read-only BMC Module Name Name bmcModuleName Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.11 Description Defines the module name for the BMC. The module name is present only on certain systems, such as modular systems. Syntax DellString Access Read-only 536 Baseboard Management Controller Group BMC IPv4 URL Name Name bmcIPv4URLName Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.12 Description Defines the IPv4 URL for the BMC. The URL is not present on all systems. Syntax DisplayString (SIZE (0..1024)) Access Read-only BMC IPv6 URL Name Name bmcIPv6URLName Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.13 Description Defines the IPv6 URL for the BMC. The URL is not present on all systems. Syntax DisplayString (SIZE (0..1024)) Access Read-only Baseboard Management Controller Serial Interface Table Name bmcSerialInterfaceTable Object ID 1.3.6.1.4.1.674.10892.1.1900.20 Description Defines the BMC Serial Interface Table. Syntax SEQUENCE OF BmcSerialInterfaceTableEntry Access Not accessible Baseboard Management Controller Group 537 BMC Serial Interface Table Entry Name bmcSerialInterfaceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1 Description Defines the BMC Serial Interface Table Entry. Syntax BmcSerialInterfaceTableEntry Access Not accessible Index bmcSerialInterfaceChassisIndex, bmcSerialInterfaceBMCIndex, bmcSerialInterfaceIndex BMC Serial Interface Chassis Index Name bmcSerialInterfaceChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1.1 Description Defines the index (one-based) of the associated chassis. Syntax DellObjectRange Access Read-only BMC Serial Interface BMC Index Name bmcSerialInterfaceBMCIndex Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1.2 Description Defines the index (one-based) of the associated BMC. Syntax DellObjectRange Access Read-only BMC Serial Interface Index Name bmcSerialInterfaceIndex Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1.3 Description Defines the index (one-based) of the BMC serial interface. Syntax DellObjectRange Access Read-only 538 Baseboard Management Controller Group BMC Serial Interface State Capabilities Name bmcSerialInterfaceStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1.4 Description Defines the state capabilities of the BMC serial interface. Syntax DellStateCapabilities Access Read-only BMC Serial Interface State Settings Name bmcSerialInterfaceStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1.5 Description Defines the state settings of the BMC serial interface. Syntax DellStateSettings Access Read-write BMC Serial Interface Status Name bmcSerialInterfaceStatus Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1.6 Description Defines the status of the BMC serial interface. Syntax DellStatus Access Read-only BMC Serial Interface Channel Number Name bmcSerialInterfaceChannelNumber Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1.7 Description Defines the BMC channel number of the BMC serial interface. Syntax DellUnsigned8BitRange Access Read-only Baseboard Management Controller Group 539 BMC Serial Interface Connection Mode Capabilities Name bmcSerialInterfaceConnectionModeCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1.8 Description Defines the connection mode capabilities of the BMC serial interface. Syntax DellBMCSerialConnectionModeCapabilities Access Read-only BMC Serial Interface Connection Mode Settings Name bmcSerialInterfaceConnectionModeSettings Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1.9 Description Defines the connection mode settings of the BMC serial interface. Syntax DellBMCSerialConnectionModeSettings Access Read-only BMC Serial Interface Flow Control Name bmcSerialInterfaceFlowControl Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1.10 Description Defines the flow control type of the BMC serial interface. Syntax DellBMCSerialFlowControlType Access Read-only BMC Serial Interface Bit Rate Name bmcSerialInterfaceBitRate Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1.11 Description Defines the bit rate of the BMC serial interface. Syntax DellBMCSerialBitRateType Access Read-only 540 Baseboard Management Controller Group Baseboard Management Controller LAN Interface Table Name bmcLANInterfaceTable Object ID 1.3.6.1.4.1.674.10892.1.1900.30 Description Defines the Baseboard Management Controller (BMC) LAN Interface Table. Syntax SEQUENCE OF BmcLANInterfaceTableEntry Access Not accessible BMC LAN Interface Table Entry Name bmcLANInterfaceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1 Description Defines the Baseboard Management Controller (BMC) LAN Interface Table Entry. Syntax BmcLANInterfaceTableEntry Access Not accessible Index bmcLANInterfaceChassisIndex, bmcLANInterfaceBMCIndex, bmcLANInterfaceIndex BMC LAN Interface Chassis Index Name bmcLANInterfaceChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.1 Description Defines the index (one-based) of the associated chassis. Syntax DellObjectRange Access Read-only Baseboard Management Controller Group 541 BMC LAN Interface BMC Index Name bmcLANInterfaceBMCIndex Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.2 Description Defines the index (one-based) of the associated BMC. Syntax DellObjectRange Access Read-only BMC LAN Interface Index Name bmcLANInterfaceIndex Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.3 Description Defines the index (one-based) of the BMC LAN interface. Syntax DellObjectRange Access Read-only BMC LAN Interface State Capabilities Name bmcLANInterfaceStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.4 Description Defines the state capabilities of the BMC LAN interface. Syntax DellStateCapabilities Access Read-only BMC LAN Interface State Settings Name bmcLANInterfaceStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.5 Description Defines the state settings of the BMC LAN interface. Syntax DellStateSettings Access Read-write 542 Baseboard Management Controller Group BMC LAN Interface Status Name bmcLANInterfaceStatus Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.6 Description Defines the status of the BMC LAN interface. Syntax DellStatus Access Read-only BMC LAN Interface Channel Number Name bmcLANInterfaceChannelNumber Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.7 Description Defines the BMC channel number of the BMC LAN interface. Syntax DellUnsigned8BitRange Access Read-only BMC LAN Interface IP Address Source Name bmcLANInterfaceIPAddressSource Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.8 Description Defines the source type of the IP address of the BMC LAN interface. Syntax DellBMCLANIPAddressSourceType Access Read-only BMC LAN Interface IP Address Name bmcLANInterfaceIPAddress Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.9 Description Defines the IP address of the BMC LAN interface. Syntax IpAddress Access Read-only Baseboard Management Controller Group 543 BMC LAN Interface Subnet Mask Address Name bmcLANInterfaceSubnetMaskAddress Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.10 Description Defines the subnet mask of the BMC LAN interface. Syntax IpAddress Access Read-only BMC LAN Interface Default Gateway Address Name bmcLANInterfaceDefaultGatewayAddress Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.11 Description Defines the IP address of the default gateway for the BMC LAN interface. Syntax IpAddress Access Read-only BMC LAN Interface MAC Address Name bmcLANInterfaceMACAddress Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.12 Description Defines the MAC address of the BMC LAN interface. Syntax DellMACAddress Access Read-only BMC LAN Interface Alert Community Name Name bmcLANInterfaceAlertCommunityName Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.13 Description Defines the SNMP community used for BMC LAN alerts (traps) sent on the BMC LAN interface. Syntax DisplayString (SIZE (0..32)) Access Read-only 544 Baseboard Management Controller Group Baseboard Management Controller Group Variable Values This section includes definitions for server administrator-specific variable values used in this section. Table 22-1. BMC Serial Connection Mode Capabilities Variable Name: DellBMCSerialConnectionModeCapabilities Data Type: Integer These values are bit masks; therefore, combination values are possible. Possible Data Values Meaning of Data Value -- none(0) No mode capabilities. modemBasic(1) BMC serial interface supports Modem Basic mode. modemPPP(2) BMC serial interface supports Modem Point to Point Protocol (PPP) mode. modemTerminal(4) BMC serial interface supports Modem Terminal mode. directBasic(8) BMC serial interface supports Direct Basic mode. directPPP(16) BMC serial interface supports Direct PPP mode. directTerminal(32) BMC serial interface supports Direct Terminal mode. Table 22-2. BMC Serial Connection Mode Settings Variable Name: DellBMCSerialConnectionModeSettings Data Type: Integer These values are bit masks; therefore, combination values are possible. Possible Data Values Meaning of Data Value -- none(0) No modes enabled. modemBasic(1) Modem Basic mode is enabled. modemPPP(2) Modem PPP mode is enabled. modemTerminal(4) Modem Terminal mode is enabled. directBasic(8) Direct Basic mode is enabled. directPPP(16) Direct PPP mode is enabled. directTerminal(32) Direct Terminal mode is enabled. Baseboard Management Controller Group 545 Table 22-3. BMC Serial Flow Control Type Variable Name: DellBMCSerialFlowControlType Data Type: Integer Possible Data Values Meaning of Data Value -- none(0) No flow control used. rtscts(1) RTS/CTS (hardware) flow control used. xonXoff(2) XON/XOFF flow control used. Table 22-4. BMC Serial Bit Rate Type Variable Name: DellBMCSerialBitRateType Data Type: Integer Possible Data Values Meaning of Data Value bps9600(6) Bit rate is 9600 bps (bits per second) bps19200(7) Bit rate is 19200 bps bps38400(8) Bit rate is 38400 bps bps57600(9) Bit rate is 57600 bps bps115200(10) Bit rate is 115200 bps Table 22-5. BMC LAN IP Address Source Type Variable Name: DellBMCLANIPAddressSourceType Data Type: Integer Possible Data Values Meaning of Data Value -- unspecified(0) Source is unspecified. static(1) IP address is static. dhcp(2) Dynamic Host Configuration Protocol (DHCP) used to obtain IP address. biosOrSystemSoftware(3) BIOS or system software provided IP Address. other(4) 546 Other protocol used to obtain IP address. Baseboard Management Controller Group Table 22-6. BMC Management Controller Type Variable Name: DellManagementControllerType Data Type: Integer Possible Data Values Meaning of Data Value -- legacyBMC(0) Controller type is legacy Baseboard Management Controller. iDRAC(8) Controller type is iDRAC. iDRAC6(10) Controller type is Integrated Dell Remote Access Controller 6. iDRAC6Modular(11) Controller type is Integrated Dell Remote Access Controller 6 (Modular). iDRAC6BMC(13) Controller type is Integrated Dell Remote Access Controller 6 (BMC mode). iDRAC7(16) Controller type is Integrated Dell Remote Access Controller 7. iDRAC7Modular(17) Controller type is Integrated Dell Remote Access Controller 7 (Modular). Baseboard Management Controller Group 547 548 Baseboard Management Controller Group 23 Field Replaceable Unit Group A field replaceable unit (FRU) is a part that can be removed and replaced without having to send the system to a repair facility. The Field Replaceable Unit Group provides information about the field replaceable units that may be present in your system. Field Replaceable Unit Group Tables The objects in the FRU group define information such as manufacturer, serial number, part number and revision for field replaceable units. The following MIB tables define the FRU group. Field Replaceable Unit Table Name fruTable Object ID 1.3.6.1.4.1.674.10892.1.2000.10 Description Defines the Field Replaceable Unit table. Syntax SEQUENCE OF FruTableEntry Access Not accessible FRU Table Entry Name fruTableEntry Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1 Description Defines the FRU Table Entry. Syntax FruTableEntry Access Not accessible Index fruChassisIndex, fruIndex Field Replaceable Unit Group 549 FRU Chassis Index Name fruChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.1 Description Defines the index (one-based) of the chassis containing the FRU. Syntax DellObjectRange Access Read-only FRU Index Name fruIndex Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.2 Description Defines the index (one-based) of the FRU. Syntax DellObjectRange Access Read-only FRU Information Status Name fruInformationStatus Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.3 Description Defines the status of the FRU table entry. Syntax DellStatus Access Read-only FRU Information State Name fruInformationState Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.4 Description Defines the state of the FRU information. Some information for the FRU may not be available if the state is other than ok(1). Syntax DellFRUInformationState Access Read-only 550 Field Replaceable Unit Group FRU Device Name Name fruDeviceName Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.5 Description Defines the device name of the FRU. Syntax DisplayString (SIZE (0..64)) Access Read-only FRU Manufacturer Name Name fruManufacturerName Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.6 Description Defines the manufacturer of the FRU. Syntax DisplayString (SIZE (0..64)) Access Read-only FRU Serial Number Name Name fruSerialNumberName Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.7 Description Defines the serial number of the FRU. Syntax DisplayString (SIZE (0..64)) Access Read-only FRU Part Number Name Name fruPartNumberName Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.8 Description Defines the part number of the FRU Syntax DisplayString (SIZE (0..64)) Access Read-only Field Replaceable Unit Group 551 FRU Revision Name Name fruRevisionName Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.9 Description Defines the revision of the FRU. Syntax DisplayString (SIZE (0..64)) Access Read-only FRU Manufacturing Date Name Name fruManufacturingDateName Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.10 Description Defines the manufacturing date of the FRU. Syntax DellDateName Access Read-only FRU Asset Tag Name Name fruAssetTagName Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.11 Description Defines the asset tag of the FRU. Syntax DisplayString (SIZE (0..64)) Access Read-only 552 Field Replaceable Unit Group Field Replaceable Unit Group Variable Values This section includes definitions for server administrator-specific variable values. Table 23-1. FRU Information State Variable Name: DellFRUInformationState Data Type: Integer Possible Data Values Meaning of Data Value ok(1) FRU information is okay. notSupported(2) FRU information is not supported. notAvailable(3) FRU information is not available. checksumInvalid(4) FRU information checksum is invalid. corrupted(5) FRU information is corrupted. Field Replaceable Unit Group 553 554 Field Replaceable Unit Group Storage Management Group 24 The Storage Management Group is composed of the following: • Storage Management Group—information about the software product and system status. • Storage Management Information Group—properties about the Simple Network Management Protocol (SNMP) agent. • Global Data Group—system status. • Physical Devices Group—physical devices managed by the software. • Logical Devices Group—logical devices managed by the software. • Storage Management Event Group—SNMP traps. Storage Management Group The Storage Management Information Base (MIB) Group defines the properties that identify information about the Storage Management software product and the current status of the system it manages. Software Version Name softwareVersion Object ID 1.3.6.1.4.1.674.10893.1.20.1 Description Identifies the version of the storage management component of the systems management software. Syntax DisplayString Access Read-only Storage Management Group 555 Global Status Name globalStatus Object ID 1.3.6.1.4.1.674.10893.1.20.2 Description Identifies the global health for the subsystem managed by the Storage Management software. This global status is customized for HP OpenView. Other applications should refer to the agentSystemGlobalStatus entry in the globalData object group. Possible values: 1: Critical 2: Warning 3: Normal 4: Unknown Syntax Integer Access Read-only Software Manufacturer Name softwareManufacturer Object ID 1.3.6.1.4.1.674.10893.1.20.3 Description Identifies the manufacturer of the Storage Management software. Syntax DisplayString Access Read-only Software Product Name softwareProduct Object ID 1.3.6.1.4.1.674.10893.1.20.4 Description Identifies product information for the Storage Management software. Syntax DisplayString Access Read-only 556 Storage Management Group Software Description Name softwareDescription Object ID 1.3.6.1.4.1.674.10893.1.20.5 Description Identifies the product description for the Storage Management software. Syntax DisplayString Access Read-only Storage Management Information Group The Storage Management Information Group defines the properties that identify the Storage Management software SNMP agent. Display Name Name displayName Object ID 1.3.6.1.4.1.674.10893.1.20.100.1 Description Identifies the name of this management software for display purposes. Syntax DisplayString Access Read-only Description Name description Object ID 1.3.6.1.4.1.674.10893.1.20.100.2 Description Provides a short description of this management software. Syntax DisplayString Access Read-only Storage Management Group 557 Agent Vendor Name agentVendor Object ID 1.3.6.1.4.1.674.10893.1.20.100.3 Description Identifies the name of the management software manufacturer. Syntax DisplayString Access Read-only Agent Version Name agentVersion Object ID 1.3.6.1.4.1.674.10893.1.20.100.4 Description This entry is obsolete. Refer to softwareVersion. Syntax DisplayString Access Read-only Global Data Group The Global Data Management Information Base (MIB) Group defines the properties that identify status information about the system that the Storage Management software is managing and about the Storage Management SNMP agent. Agent System Global Status Name agentSystemGlobalStatus Object ID 1.3.6.1.4.1.674.10893.1.20.110.1 Description This entry is obsolete. Use the value agentGlobalSystemStatus. Syntax Integer Access Read-only 558 Storage Management Group Agent Last Global Status Name agentLastGlobalStatus Object ID 1.3.6.1.4.1.674.10893.1.20.110.2 Description This entry is obsolete. Use the value agentLastGlobalSystemStatus. Syntax Integer Access Read-only Agent Time Stamp Name agentTimeStamp Object ID 1.3.6.1.4.1.674.10893.1.20.110.3 Description Identifies the last time the agent values have been updated. Universal time in seconds since UTC 1/1/70. Syntax Integer Access Read-only Agent Get Timeout Name agentGetTimeout Object ID 1.3.6.1.4.1.674.10893.1.20.110.4 Description Indicates the suggested timeout value, in milliseconds, for how long the SNMP getter should wait while attempting to poll the SNMP agent. Syntax Integer Access Read-only Storage Management Group 559 Agent Modifiers Name agentModifiers Object ID 1.3.6.1.4.1.674.10893.1.20.110.5 Description Identifies the agent functional modifiers. When Agent Modifier is set, the modifier is active. Bit definitions: Bit 3: agent in debug mode. All other bits are product specific. Syntax Integer Access Read-only Agent Refresh Rate Name agentRefreshRate Object ID 1.3.6.1.4.1.674.10893.1.20.110.6 Description Identifies the rate, given in seconds, at which the cached data for SNMP is refreshed. The default value is 300 seconds, or 5 minutes. Syntax Integer Access Read-only Agent Hostname Name agentHostname Object ID 1.3.6.1.4.1.674.10893.1.20.110.7 Description This entry is obsolete for Storage Management. Syntax DisplayString Access Read-only 560 Storage Management Group Agent IP Address Name agentIPAddress Object ID 1.3.6.1.4.1.674.10893.1.20.110.8 Description This entry is obsolete for Storage Management. Syntax DisplayString Access Read-only Agent Software Status Name agentSoftwareStatus Object ID 1.3.6.1.4.1.674.10893.1.20.110.9 Description This entry is obsolete for Storage Management. Syntax DisplayString Access Read-only Agent SNMP Version Name agentSnmpVersion Object ID 1.3.6.1.4.1.674.10893.1.20.110.10 Description This entry is obsolete. Refer to 0001 softwareVersion. Syntax DisplayString Access Read-only Agent MIB Version Name agentMibVersion Object ID 1.3.6.1.4.1.674.10893.1.20.110.11 Description Identifies the version of the Storage Management MIB. Syntax DisplayString Access Read-only Storage Management Group 561 Agent Management Software URL Name Name agentManagementSoftwareURLName Object ID 1.3.6.1.4.1.674.10893.1.20.110.12 Description Identifies the Universal Resource Locator (URL) of the systems management software. Syntax DisplayString Access Read-only Agent Global System Status Name agentGlobalSystemStatus Object ID 1.3.6.1.4.1.674.10893.1.20.110.13 Description Identifies the global health information for the subsystem managed by the Storage Management software. This is a rollup for the entire agent including any monitored devices. The status is intended to give initiative to an SNMP monitor to get further data when this status is abnormal. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable NOTE: This global status should be used by applications other than HP OpenView. HP OpenView should refer to the globalStatus in the root level object group. Syntax DellStatus Access Read-only 562 Storage Management Group Agent Last Global System Status Name agentLastGlobalSystemStatus Object ID 1.3.6.1.4.1.674.10893.1.20.110.14 Description Identifies the previous global status of the system managed by the Storage Management software. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Agent Smart Thermal Shutdown Name agentSmartThermalShutdown Object ID 1.3.6.1.4.1.674.10893.1.20.110.15 Description Indicates the status of smart thermal shutdown for PowerVault 220S and PowerVault 221S enclosures. Possible values: 1: Enabled 2: Disabled 3: Not applicable Syntax Integer Access Read-only Storage Management Group 563 Physical Devices Group The Physical Devices MIB group provides information about the devices managed by the Storage Management software and their relationships to each other. The following MIB tables define objects and relationships (connections) among the objects. 564 • Controller Table—describes available properties for each controller on the managed system. • Channel Table—describes available properties for each channel on the managed system. • Enclosure Table—describes available properties for each enclosure on the managed system. • Array Disk Table—describes available properties for each physical array disk on the managed system. • Array Disk Enclosure Connection Table—describes the connections between Fibre Channel array disks, their enclosure, and their associated controller. For each object in the table, its object number corresponds to an instance number in the appropriate MIB table for that object where all of the object properties can be found. • Array Disk Channel Connection Table—describes the connections between SCSI array disks, their channel, and their associated controller. For each object in the table, its object number corresponds to an instance number in the appropriate MIB table for that object where all of the object properties can be found. • Fan Table—describes available properties for each fan on the managed system. • Fan Connection Table—describes the connection between each fan on the managed system and its enclosure. Each enclosure number in the table corresponds to that enclosure instance in the Enclosure Table. • Power Supply Table—describes available properties for each power supply on the managed system. • Power Supply Connection Table—describes the connection between each power supply on the managed system and its enclosure. Each enclosure number in the table corresponds to that enclosure instance in the Enclosure Table. Storage Management Group • Temperature Probe Table—describes available properties for each temperature probe on the managed system. • Temperature Probe Connection Table—describes the connection between each temperature probe on the managed system and its enclosure. Each enclosure number in the table corresponds to that enclosure instance in the Enclosure Table. • EMM Table—describes available properties for each Enclosure Management Module (EMM) on the managed system. • EMM Connection Table—describes the connection between each EMM on the managed system and its enclosure. Each enclosure number in the table corresponds to that enclosure instance in the Enclosure Table. • Battery Table—describes available properties for each controller battery on the managed system. • Battery Connection Table—describes the connection between each battery on the managed system and its controller. Each controller number in the table corresponds to that controller instance in the Controller Table. Controller Table This table describes available properties for each controller on the managed system. The following object sets up the Controller Table. Name controllerTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.1 Description Defines the controller table, which is a table of managed Redundant Array of Independent disks (RAID) controllers. The number of entries is related to the number of RAID controllers discovered by the system. Syntax SEQUENCE OF ControllerEntry Access Not accessible Storage Management Group 565 Controller Entry Name controllerEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1 Description Defines the controller table entry, which is an entry in the table of RAID controllers. Syntax ControllerEntry Access Not accessible Index controllerNumber Controller Number Name controllerNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.1 Description Identifies the instance number of the controller entry. Syntax Integer Access Read-only Controller Name Name controllerName Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.2 Description Identifies the name of the controller in this subsystem as represented in Storage Management. Includes the controller type and instance. For example: PERC 3/QC 1. Syntax DisplayString Access Read-only 566 Storage Management Group Controller Vendor Name controllerVendor Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.3 Description Identifies the controller's vendor's name. Syntax DisplayString Access Read-only Controller Type Name controllerType Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.4 Description Identifies the type of controller: 1: SCSI 2: PowerVault 660F 3: Power Vault 662F 4: Integrated/Intelligent Drive Electronics (IDE) 5: Serial Advanced Technology Architecture (SATA) 6: Serial Attached SCSI (SAS) 9: PCIe SSD Syntax Integer Access Read-only Controller State Name controllerState Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.5 Storage Management Group 567 Name controllerState Description Identifies the status of the controller's subsystem (which includes any devices connected to it). Possible states: 0: Unknown 1: Ready 2: Failed 3: Online 4: Offline 6: Degraded Syntax Integer Access Read-only Controller Severity Name controllerSeverity Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.6 Description This entry is obsolete for Storage Management. It was replaced with RollUpStatus and ComponentStatus for each device. Syntax Integer Access Read-only Controller Rebuild Rate in Percent Name controllerRebuildRateInPercent Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.7 Description Identifies the percent of the compute cycles dedicated to rebuilding failed array disks. Syntax Integer Access Read-only 568 Storage Management Group Controller Firmware Version Name controllerFWVersion Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.8 Description Identifies the controller's current firmware version. Syntax DisplayString Access Read-only Controller Cache Size in Megabytes Name controllerCacheSizeInMB Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.9 Description Identifies the controller's current amount of cache memory in megabytes. If this size is 0, the cache memory is less than a megabyte. Syntax Integer Access Read-only Controller Cache Size in Bytes Name controllerCacheSizeInBytes Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.10 Description Identifies the controller's current amount of cache memory that is less than a megabyte. This combined with the controllerCacheSizeInMB is the total amount of memory. Syntax Integer Access Read-only Controller Physical Device Count Name controllerPhysicalDeviceCount Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.11 Description Identifies the number of physical devices on the controller channel including both disks and the controller. Syntax Integer Storage Management Group 569 Name controllerPhysicalDeviceCount Access Read-only Controller Logical Device Count Name controllerLogicalDeviceCount Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.12 Description Identifies the number of virtual disks on the controller. Syntax Integer Access Read-only Controller Partner Status Name controllerPartnerStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.13 Description This entry is obsolete for Storage Management. Syntax DisplayString Access Read-only Controller Host Port Count Name controllerHostPortCount Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.14 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax Integer Access Read-only Controller Memory Size in Megabytes Name controllerMemorySizeInMB Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.15 570 Storage Management Group Name controllerMemorySizeInMB Description Identifies the size of memory in megabytes on the controller. If this size is 0, it is less than a megabyte. NOTE: This attribute is only supported on Adaptec controllers. Syntax Integer Access Read-only Controller Memory Size in Bytes Name controllerMemorySizeInBytes Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.16 Description Identifies the size of memory on the controller that is less than a megabyte. This combined with the controllerMemorySizeInMB is the total size of the memory. NOTE: This attribute is only supported on Adaptec controllers. Syntax Integer Access Read-only Controller Drive Channel Count Name controllerDriveChannelCount Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.17 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax Integer Access Read-only Controller Fault Tolerant Name controllerFaultTolerant Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.18 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax Integer Storage Management Group 571 Name controllerFaultTolerant Access Read-only Controller C0 Port 0 World Wide Name Name controllerC0Port0WorldWideName Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.19 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax DisplayString Access Read-only Controller C0 Port 0 Name Name controllerC0Port0Name Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.20 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax DisplayString Access Read-only Controller C0 Port 0 ID Name controllerC0Port0ID Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.21 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax Integer Access Read-only Controller C0 Target Name controllerC0Target Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.22 572 Storage Management Group Name controllerC0Target Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax Integer Access Read-only Controller C0 Channel Name controllerC0Channel Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.23 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax Integer Access Read-only Controller C0 Operating System Controller Name controllerC0OSController Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.24 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax DisplayString Access Read-only Controller C0 Battery State Name controllerC0BatteryState Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.25 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax Integer Access Read-only Storage Management Group 573 Controller C1 Port 0 World Wide Name Name controllerC1Port0WWN Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.26 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax DisplayString Access Read-only Controller C1 Port 0 Name Name controllerC1Port0Name Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.27 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax DisplayString Access Read-only Controller C1 Port 0 ID Name controllerC1Port0ID Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.28 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax Integer Access Read-only Controller C1 Target Name controllerC1Target Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.29 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax Integer Access Read-only 574 Storage Management Group Controller C1 Channel Name controllerC1Channel Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.30 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax Integer Access Read-only Controller C1 Operating System Controller Name controllerC1OSController Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.31 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax DisplayString Access Read-only Controller Battery State C1 Name controllerC1BatteryState Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.32 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax Integer Access Read-only Controller Node World Wide Name Name controllerNodeWWN Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.33 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax DisplayString Access Read-only Storage Management Group 575 Controller C0 Port 1 World Wide Name Name controllerC0Port1WWN Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.34 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax DisplayString Access Read-only Controller C1 Port 1 World Wide Name Name controllerC1Port1WWN Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.35 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax DisplayString Access Read-only Controller Battery Charge Count Name controllerBatteryChargeCount Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.36 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax Integer Access Read-only Controller Roll-Up Status Name controllerRollUpStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.37 576 Storage Management Group Name controllerRollUpStatus Description Indicates severity of the controller state. This is the combined status of the controller and its components. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Controller Component Status Name controllerComponentStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.38 Description Indicates the status of the controller itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Controller Nexus ID Name controllerNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.39 Description Displays the durable unique ID for this controller. Syntax DisplayString Storage Management Group 577 Name controllerNexusID Access Read-only Controller Alarm State Name controllerAlarmState Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.40 Description Indicates the state or setting for the controller's alarm. Possible values: 1: Enabled 2: Disabled 3: Not Applicable Syntax Integer Access Read-only Controller Driver Version Name controllerDriverVersion Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.41 Description Indicates the currently installed driver version of the controller. Syntax DisplayString Access Read-only Controller PCI Slot Name controllerPCISlot Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.42 Description Indicates the PCI slot number or embedded number for controllers on the motherboard. Syntax DisplayString Access Read-only 578 Storage Management Group Controller Cluster Mode Name controllerClusterMode Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.43 Description Identifies if the controller is in cluster mode. Possible values: 1: Enabled 2: Disabled 3: Active (enabled and active) 99: Not Applicable Syntax Integer Access Read-only Controller Minimum Firmware Version Name controllerMinFWVersion Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.44 Description The minimum firmware version for Storage Management to support the controller. Syntax DisplayString Access Read-only Controller Minimum Driver Version Name controllerMinDriverVersion Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.45 Description The minimum driver version for Storage Management to support the controller. Syntax DisplayString Access Read-write Storage Management Group 579 Controller SCSI Initiator ID Name controllerSCSIInitiatorID Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.46 Description Displays the SCSI ID of the initiator. Syntax Integer Access Read-only Controller Channel Count Name controllerChannelCount Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.47 Description Displays the number of channels on the controller. Syntax Integer Access Read-only Controller Reconstruct Rate Name controllerReconstructRate Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.48 Description Displays the rate for reconstruct on the controller. Syntax Integer Access Read-write Controller Patrol Read Rate Name controllerPatrolReadRate Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.49 Description Displays the rate for patrol read on the controller. Syntax Integer Access Read-only 580 Storage Management Group Controller BGI Rate Name controllerBGIRate Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.50 Description Displays the rate for background initialization on the controller. Syntax Integer Access Read-only Controller Check Consistency Rate Name controllerCheckConsistencyRate Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.51 Description Displays the rate for check consistency on the controller. Syntax Integer Access Read-only Controller Patrol Read Mode Name controllerPatrolReadMode Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.52 Description Identifies the patrol read mode. Possible values: 1: Automatic (enabled) 2: Manual (enabled) 3: Disabled Syntax Integer Access Read-only Controller Patrol Read State Name controllerPatrolReadState Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.53 Storage Management Group 581 Name controllerPatrolReadState Description Displays the state of the patrol read. Possible values: 1: Stopped - not running 2: Ready - ready to start 4: Active - is running 8: Aborted - has aborted Syntax Integer Access Read-only Controller Patrol Read Iterations Name controllerPatrolReadIterations Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.54 Description Displays the number of times Patrol Read has been run on this controller. Syntax Integer Access Read-only Controller Storport Driver Version Name controllerStorportDriverVersion Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.55 Description Provides current Windows OS storport driver version. NOTE: Not applicable for Linux. Syntax Octet String Access Read-only 582 Storage Management Group Controller Minimum Required Storport Version Name controllerMinimumRequiredStorportVersion Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.56 Description Provides minimum required storport driver version for Windows OS only. NOTE: Not applicable for Linux. Syntax Octet String Access Read-only Controller Encryption Capable Name controllerEncryptionCapable Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.57 Description Indicates the encryption capability of the controller. Possiable Values: 1 - Capable 99 - Not Applicable Syntax Integer Access Read-only Controller Encryption Key Present Name controllerEncryptionKeyPresent Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.58 Description Indicates presence of encryption key for the controller. Possiable Values: 1 - Yes 0 - No 99 - Not Applicable Syntax Integer Access Read-only Storage Management Group 583 Controller Persistent Hot Spare Name controllerPersistentHotSpare Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.59 Description Indicates the Persistent Hot Spare capability of the controller. Possiable Values: 1 - Enabled 0 - Disabled 99 - Undetermined / Not applicable Syntax Integer Access Read-only Controller Spin Down Unconfigured Drives Name controllerSpinDownUnconfiguredDrives Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.60 Description Indicates controller capability to move unconfigured drives to power save mode. Possiable Values: 1 - Enabled 0 - Disabled 99 - Undetermined / Not applicable Syntax Integer Access Read-only Controller Spin Down Hot Spare Drives Name controllerSpinDownHotSpareDrives Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.61 Description Indicates controller capability to move hot spare drives to power save mode. Possiable Values: 1 - Enabled 0 - Disabled 99 - Undetermined / Not applicable 584 Storage Management Group Name controllerSpinDownHotSpareDrives Syntax Integer Access Read-only Storage Management Group 585 Controller Spin Down Time Interval Name controllerSpinDownTimeInterval Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.62 Description Shows the duration in minutes after which, the unconfigured or hot spare drives is spun down to power save mode. Possiable Values: 30 to 1440 NOTE: A value of 9999 indicates that the feature is not available. Syntax Integer Access Read-write Controller Encryption Mode Name controllerEncryptionMode Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.63 Description Indicates the current encryption mode of the controller. Possiable Values: 0 - No Encryption 1 - Local Key Management (LKM) 2 - Dell Key Management (DKM) 99 - Not Applicable Syntax Integer Access Read-only Controller CacheCade Name controllerCacheCade Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.64 Description Indicates if the controller is CacheCade capable or not. Possiable Values: 1 - Capable 0 - Not Capable 99 - Undetermined Syntax Integer Access Read-only 586 Storage Management Group Controller Spin Down Configured Drives Name controllerSpinDownConfiguredDrives Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.65 Description Indicates the controller capability to spin down configured physical disks. Possiable Values: 0 - Disabled 1 - Enabled 99 - Undetermined Syntax Integer Access Read-only Controller Automatic Power Saving Name controllerAutomaticPowerSaving Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.66 Description Indicates the controller capability for automatic power saving. Possiable Values: 0 - Disabled 1 - Enabled 99 - Undetermined Syntax Integer Access Read-only Controller Configured Drives SpinUp Time Name controllerConfiguredDrivesSpinUpTime Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.67 Description Indicates the configured drives spin up start time. Possiable Values: 1:00 AM to 12:59 PM 9999 - Undetermined Syntax DisplayString Storage Management Group 587 Name controllerConfiguredDrivesSpinUpTime Access Read-only Controller Configured Drives SpinUp TimeInterval Name controllerConfiguredDrivesSpinUpTimeInterval Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.68 Description Indicates the configured drives spin up time interval in hours. This value is added with the configured drives at start time to arrive at time window in which configured drives are always spin up. Possiable Values: 1 .. 24, 9999 - Undetermined Syntax Integer Access Read-only Controller Preserved Cache Name controllerPreservedCache Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.69 Description Indicates if the preserved cache is present on the controller. Possiable Values: 1- Yes 0 - No 99 - Not available / Not applicable Syntax Integer Access Read-only 588 Storage Management Group Channel Table This section describes available properties for each channel on the managed system. The following object sets up the Channel Table. Name channelTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.2 Description Defines the channel table. Syntax SEQUENCE OF ChannelEntry Access Not accessible Channel Entry Name channelEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1 Description Defines the channel table entry. Syntax ChannelEntry Access Not accessible Index: channelNumber Channel Number Name channelNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.1 Description Identifies the instance number of the channel entry. Syntax Integer Access Read-only Channel Name Name channelName Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.2 Storage Management Group 589 Name channelName Description Identifies the name of the channel as represented in Storage Management. The name includes the word channel and the instance. For example: Channel 1. Syntax DisplayString Access Read-only Channel State Name channelState Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.3 Description Identifies the current state of the channel. Possible states: 0: Unknown 1: Ready - The I/O has resumed 2: Failed 3: Online 4: Offline - The I/O has paused 6: Degraded Syntax Integer Access Read-only Channel Severity Name channelSeverity Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.4 Description This entry is obsolete for Storage Management. It is replaced with RollUpStatus and ComponentStatus for each device. Syntax Integer Access Read-only 590 Storage Management Group Channel Termination Name channelTermination Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.5 Description Identifies the type of SCSI termination on the channel. Termination is required for proper operation of the channel. Possible values: 1: Wide Termination (16 bit) 2: Narrow Termination (8 bit) 3: Not Terminated Syntax Integer Access Read-only Channel SCSI ID Name channelSCSIID Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.6 Description Identifies the SCSI ID of the controller to which the channel belongs. Syntax Integer Access Read-only Storage Management Group 591 Channel Roll-Up Status Name channelRollUpStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.7 Description Identifies the severity of the channel state. This is the combined status of the channel and its components. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Channel Component Status Name channelComponentStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.8 Description The status of the channel itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only 592 Storage Management Group Channel Nexus ID Name channelNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.9 Description Displays the durable unique ID for the channel. Syntax DisplayString Access Read-only Channel Data Rate Name channelDataRate Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.10 Description Identifies the data rate of the channel. Syntax DisplayString Access Read-only Channel Bus Type Name channelBusType Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.11 Description Identifies the bus type of the channel. Possible values: 1: SCSI 2: IDE 3: Fibre Channel 4: Serial Storage Architecture (SSA) 6: Universal Serial Bus (USB) 7: SATA 8: SAS 9: PCIe Syntax Integer Access Read-only Storage Management Group 593 Enclosure Table This section describes available properties for each enclosure on the managed system. The following object sets up the Enclosure Table. Name enclosureTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.3 Description Defines the enclosure table. Syntax SEQUENCE OF EnclosureEntry Access Not accessible Enclosure Entry Name enclosureEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1 Description Defines the enclosure table entry. Syntax EnclosureEntry Access Not accessible Index enclosureNumber Enclosure Number Name enclosureNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.1 Description Identifies the instance number of the enclosure entry. Syntax Integer Access Read-only 594 Storage Management Group Enclosure Name Name enclosureName Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.2 Description Identifies the enclosure's name as represented in Storage Management. Syntax DisplayString Access Read-only Enclosure Vendor Name enclosureVendor Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.3 Description Identifies the enclosure's (re)seller's name. Syntax DisplayString Access Read-only Enclosure State Name enclosureState Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.4 Description Identifies the current condition of the enclosure (which includes any devices connected to it.) Possible values: 0: Unknown 1: Ready 2: Failed 3: Online 4: Offline 6: Degraded Syntax Integer Access Read-only Storage Management Group 595 Enclosure Severity Name enclosureSeverity Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.5 Description This entry is obsolete for Storage Management. It is replaced with RollUpStatus and ComponentStatus for each device. Syntax Integer Access Read-only Enclosure ID Name enclosureID Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.6 Description Represents the unique id for an enclosure. Syntax DisplayString Access Read-only Enclosure Processor Version Name enclosureProcessorVersion Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.7 Description This entry is obsolete for Storage Management. Syntax DisplayString Access Read-only Enclosure Service Tag Name enclosureServiceTag Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.8 Description Displays the enclosure identification used when consulting customer support. Syntax DisplayString Access Read-only 596 Storage Management Group Enclosure Asset Tag Name enclosureAssetTag Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.9 Description Displays the customer definable asset tag for the enclosure. Syntax DisplayString Access Read-only Enclosure Asset Name Name enclosureAssetName Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.10 Description Displays the customer definable asset name of the enclosure. Syntax DisplayString Access Read-only Enclosure Split Bus Part Number Name enclosureSplitBusPartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.11 Description Identifies the enclosure's split bus part number. Syntax DisplayString Access Read-only Enclosure Product ID Name enclosureProductID Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.12 Description Displays the enclosure's product identification. This also corresponds to the enclosure type. Syntax DisplayString Access Read-only Storage Management Group 597 Enclosure Kernel Version Name enclosureKernelVersion Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.13 Description This entry is obsolete for Storage Management. Syntax DisplayString Access Read-only Enclosure ESM1 Part Number Name enclosureESM1PartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.14 Description This entry is obsolete for Storage Management. Syntax DisplayString Access Read-only Enclosure ESM2 Part Number Name enclosureESM2PartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.15 Description This entry is obsolete for Storage Management. Syntax DisplayString Access Read-only 598 Storage Management Group Enclosure Type Name enclosureType Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.16 Description Indicates the type of the enclosure. Possible values: 1: Internal 2: Dell PowerVault 200S (PowerVault 201S) 3: Dell PowerVault 210S (PowerVault 211S) 4: Dell PowerVault 220S (PowerVault 221S) 5: Dell PowerVault 660F 6: Dell PowerVault 224F 7: Dell PowerVault 660F/PowerVault 224F 8: Dell MD1000 9: Dell MD1120 Syntax DisplayString Access Read-only Enclosure Processor2 Version Name enclosureProcessor2Version Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.17 Description This entry is obsolete for Storage Management. Syntax DisplayString Access Read-only Storage Management Group 599 Enclosure Configuration Name enclosureConfig Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.18 Description Identifies the current configuration of the enclosure's backplane. Possible values: 1: Joined 2: Split Bus 3: Clustered 4: Unified Syntax Integer Access Read-only Enclosure Channel Number Name enclosureChannelNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.19 Description Identifies the channel number, or bus, to which the enclosure is connected. Syntax Integer Access Read-only Enclosure Alarm Name enclosureAlarm Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.20 Description Identifies the current status of the enclosure's alarm (PowerVault 220S and PowerVault 221S only.) Possible values: 1: Disabled 2: Enabled Syntax Integer Access Read-only 600 Storage Management Group Enclosure Backplane Part Number Name enclosureBackplanePartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.21 Description Identifies the part number of the enclosure's backplane. Syntax Integer Access Read-only Enclosure SCSI ID Name enclosureSCSIID Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.22 Description Identifies the SCSI ID of the controller to which the enclosure is attached. Syntax Integer Access Read-only Enclosure Roll-Up Status Name enclosureRollUpStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.23 Description Identifies the severity of the enclosure state. This is the combined status of the enclosure and its components. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Storage Management Group 601 Enclosure Component Status Name enclosureComponentStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.24 Description Identifies the status of the enclosure itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Enclosure Nexus ID Name enclosureNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.25 Description Identifies the durable unique ID for the enclosure. Syntax Integer Access Read-only Enclosure FirmWare Version Name enclosureFirmwareVersion Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.26 Description Displays the firmware version of the enclosure. Syntax DisplayString Access Read-only 602 Storage Management Group Enclosure SCSI Rate Name enclosureSCSIRate Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.27 Description Displays the actual SCSI rate in the enclosure. Syntax DisplayString Access Read-only Enclosure Part Number Name enclosurePartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.28 Description Displays the part number of the enclosure. Syntax DisplayString Access Read-only Enclosure Serial Number Name enclosureSerialNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.29 Description Displays the serial number of the enclosure. Syntax DisplayString Access Read-only Enclosure SAS Address Name enclosureSASAddress Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.30 Description Displays the specified SAS address if the enclosure is a SAS enclosure. Syntax DisplayString Access Read-only Storage Management Group 603 Enclosure Occupied Slot Count Name enclosureOccupiedSlotCount Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.31 Description Displays the number of physical disk slots occupied in a storage enclosure. NOTE: A value of 9999 indicates that the feature is not available. Syntax Integer Access Read-only Enclosure Total Slots Name enclosureTotalSlots Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.32 Description Displays the total number of physical slots in a storage enclosure; it includes total count of occupied and empty slots. NOTE: A value of 9999 indicates that the feature is not available. Syntax Integer Access Read-only Enclosure Empty Slot Count Name enclosureEmptySlotCount Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.33 Description Displays the number of empty physical disk slots in a storage enclosure. NOTE: A value of 9999 indicates that the feature is not available Syntax Integer Access Read-only 604 Storage Management Group Array Disk Table This section describes available properties for each physical array disk on the managed system. The following object sets up the Array Disk Table. Name arrayDiskTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.4 Description Defines the array disk table. Syntax SEQUENCE OF ArrayDiskEntry Access Not accessible Array Disk Entry Name arrayDiskEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1 Description Defines the array disk table entry. Syntax ArrayDiskEntry Access Not accessible Index arrayDiskNumber Array Disk Number Name arrayDiskNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.1 Description Identifies the instance number of the array disk entry. Syntax Integer Access Read-only Storage Management Group 605 Array Disk Name Name arrayDiskName Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.2 Description Identifies the name of the array disk as represented in Storage Management. Syntax DisplayString Access Read-only Array Disk Vendor Name arrayDiskVendor Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.3 Description Displays the array disk's manufacturer's name. Syntax DisplayString Access Read-only 606 Storage Management Group Array Disk State Name arrayDiskState Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.4 Storage Management Group 607 Name arrayDiskState Description Identifies the current state of the array disk. Possible states: 0: Unknown 1: Ready - Available for use, but no RAID configuration has been assigned. 2: Failed - Not operational. 3: Online - Operational. RAID configuration has been assigned. 4: Offline - The drive is not available to the RAID controller. 6: Degraded - Refers to a fault-tolerant array/virtual disk that has a failed disk. 7: Recovering - Refers to a state of recovering from bad blocks on disks. 11: Removed - Indicates that the array disk has been removed. 13: Non-RAID - Indicates that the array disk is not a RAID capable disk. 14: Not Ready - Applicable for PCIeSSD devices indicating that the device is in locked state. 15: Resynching - Indicates one of the following types of disk operations: Transform Type, Reconfiguration, and Check Consistency. 22: Replacing - Indicates copyback operation is in progress. 24: Rebuild 25: No Media - CD-ROM or removable disk has no media. 26: Formatting - In the process of formatting. 28: Diagnostics - Diagnostics are running. 34: Predictive Failure 35: Initializing: Applies only to virtual disks on PERC, PERC 2/SC, and PERC 2/DC controllers. 39: Foreign 40: Clear 41: Unsupported 53: Incompatible 56: Read Only - Applicable for PCIeSSD devices. Indicates that device has reached read-only state. 608 Storage Management Group Name arrayDiskState Syntax Integer Access Read-only Array Disk Severity Name arrayDiskSeverity Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.5 Description This entry is obsolete for Storage Management. It is replaced with RollUpStatus and ComponentStatus for each device. Syntax Integer Access Read-only Array Disk Product ID Name arrayDiskProductID Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.6 Description Identifies the model number of the array disk. Syntax DisplayString Access Read-only Array Disk Serial Number Name arrayDiskSerialNo Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.7 Description Identifies the array disk's unique identification number from the manufacturer. Syntax DisplayString Access Read-only Storage Management Group 609 Array Disk Revision Name arrayDiskRevision Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.8 Description Identifies the firmware version of the array disk. Syntax DisplayString Access Read-only Array Disk Enclosure ID Name arrayDiskEnclosureID Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.9 Description Identifies the SCSI ID of the enclosure processor to which the array disk belongs. Syntax DisplayString Access Read-only Array Disk Channel Name arrayDiskChannel Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.10 Description Identifies the bus to which the array disk is connected. Syntax Integer Access Read-only Array Disk Length in Megabytes Name arrayDiskLengthInMB Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.11 Description Identifies the size, in megabytes of the array disk. If this size is 0, the size is smaller than a megabyte. Syntax Integer Access Read-only 610 Storage Management Group Array Disk Length in Bytes Name arrayDiskLengthInBytes Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.12 Description Identifies the size of the array disk (in bytes) that is less than a megabyte. This size plus the arrayDiskLengthInMB is the total size of the array disk. Syntax Integer Access Read-only Array Disk Largest Contiguous Free Space in Megabytes Name arrayDiskLargestContiguousFreeSpaceInMB Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.13 Description The size in (megabytes) of the largest contiguous free space on the array disk. If this size is 0, the free space on the array dissk is less than a megabyte. Syntax Integer Access Read-only Array Disk Largest Contiguous Free Space in Bytes Name arrayDiskLargestContiguousFreeSpaceInBytes Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.14 Description The size of the largest contiguous free space on this array disk (in bytes) that is less than a megabyte.This size plus the arrayDiskLargestContiguousFreeSpaceInMB is the total size of the largest contiguous free space on the array disk. Syntax Integer Access Read-only Array Disk Target ID Name arrayDiskTargetID Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.15 Description Identifies the SCSI target ID to which the array disk is assigned. Storage Management Group 611 Name arrayDiskTargetID Syntax Integer Access Read-only Array Disk LUN ID Name arrayDiskLunID Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.16 Description Identifies the array disk's logical unit number. Syntax Integer Access Read-only Array Disk Used Space in Megabytes Name arrayDiskUsedSpaceInMB Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.17 Description Identifies the amount (in megabytes) of used space on the array disk. If this size is 0, used space on the array disk is smaller than a megabyte. Syntax Integer Access Read-only Array Disk Used Space in Bytes Name arrayDiskUsedSpaceInBytes Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.18 Description Identifies the size in bytes of the used space on the array disk that is smaller than a megabyte. This size plus the arrayDiskUsedSpaceInMB is the total amount of used space on the array disk. Syntax Integer Access Read-only 612 Storage Management Group Array Disk Free Space in Megabytes Name arrayDiskFreeSpaceInMB Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.19 Description Identifies the amount (in megabytes) of the free space on the array disk. If this size is 0, the free space on the array disk is smaller than a megabyte. Syntax Integer Access Read-only Storage Management Group 613 Array Disk Free Space in Bytes Name arrayDiskFreeSpaceInBytes Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.20 Description Identifies the size (in bytes) of the free space on the array disk that is smaller than a megabyte. This size plus the arrayDiskFreeSpaceInMB is the total amount of free space on the array disk. Syntax Integer Access Read-only Array Disk Bus Type Name arrayDiskBusType Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.21 Description Identifies the bus type of the array disk. Possible values: 1: SCSI 2: IDE 3: Fibre Channel 4: SSA 6: USB 7: SATA 8: SAS 9: PCIe Syntax Integer Access Read-only 614 Storage Management Group Array Disk Spare State Name arrayDiskSpareState Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.22 Description Identifies the status of the array disk as a spare. Possible states: 1: Disk is a member of a virtual disk 2: Disk is a member of a disk group 3: Disk is a global hot spare 4: Disk is a dedicated hot spare 5: Not a spare 99: Not applicable Syntax Integer Access Read-only Array Disk Roll-Up Status Name arrayDiskRollUpStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.23 Description Identifies the severity of the array disk state. This is the combined status of the array disk and its components. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Storage Management Group 615 Array Disk Component Status Name arrayDiskComponentStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.24 Description Identifies the status of the array disk itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Array Disk Device Name Name arrayDiskDeviceName Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.25 Description Identifies the operating system device name for the array disk. Syntax DisplayString Access Read-only Array Disk Nexus ID Name arrayDiskNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.26 Description Indicates the durable unique ID for the array disk. Syntax DisplayString Access Read-only 616 Storage Management Group Array Disk Part Number Name arrayDiskPartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.27 Description Indicates the part number of the disk. Syntax DisplayString Access Read-only Array Disk SAS Address Name arrayDiskSASAddress Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.28 Description Indicates the specified SAS address if this is a SAS disk. Syntax DisplayString Access Read-only Array Disk Negotiated Speed Name arrayDiskNegotiatedSpeed Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.29 Description Indicates the speed at which the drive is actually running in MPS (megabytes per second). Syntax Integer Access Read-only Array Disk Capable Speed Name arrayDiskCapableSpeed Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.30 Description Indicates the maximum speed at which the drive is capable of negotiating in MPS (megabytes per second). Syntax Integer Access Read-only Storage Management Group 617 Array Disk Smart Alert Indication Name arrayDiskSmartAlertIndication Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.31 Description Indicates whether the disk has received a predictive failure. Possible values: 1: No - disk has not received a predictive failure alert 2: Yes - disk has received a predictive failure alert Syntax Integer Access Read-only Array Disk Manufacture Day Name arrayDiskManufactureDay Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.32 Description Indicates the day of the week (1=Sunday through 7=Saturday) the disk was manufactured. Syntax DisplayString Access Read-only Array Disk Manufacture Week Name arrayDiskManufactureWeek Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.33 Description Indicates the week (1 through 53) in which the disk was manufactured. Syntax DisplayString Access Read-only 618 Storage Management Group Array Disk Manufacture Year Name arrayDiskManufactureYear Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.34 Description Indicates the four digit year in which the disk was manufactured. Syntax DisplayString Access Read-only Array Disk Media Type Name arrayDiskMediaType Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.35 Description Indicates the Media type of the array disk. Possible Values: 1:unknown 2:hdd 3:ssd Syntax Integer Access Read-only Array Disk Dell Certified Name arrayDiskDellCertified Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.36 Description Indicates if the array disk is certified by Dell. Possible Values: 1 - Certified 0 - Not Certified 99 - Unknown Syntax Integer Access Read-only Storage Management Group 619 Array Disk Alta Vendor Id Name arrayDiskAltaVendorId Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.37 Description Provides the vendor information for Alta interposer. Syntax Octet String Access Read-only Array Disk Alta Product Id Name arrayDiskAltaProductId Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.38 Description Provides the product ID for Alta interposer. Syntax Octet String Access Read-only Array Disk Alta Revision Id Name arrayDiskAltaRevisionId Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.39 Description Provides the revision ID for Alta interposer. Syntax Octet String Access Read-only Array Disk Encryption Capable Name arrayDiskEncryptionCapable Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.40 Description Indicates if the physical disk is encryption capable. Possible Values: 1 - Capable 0 - Not Capable 99 - Not Applicable Syntax 620 Integer Storage Management Group Name arrayDiskEncryptionCapable Access Read-only Array Disk Encrypted Name arrayDiskEncrypted Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.41 Description Indicates if the physical disk is encryption enabled. Possible Values: 1 - Yes 0 - No 99 - Not Applicable Syntax Integer Access Read-only Array Disk Power State Name arrayDiskPowerState Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.42 Description Indicates the power state of a physical drive. Possible Values: 0 - Spun up 1- Spun down 255 - Transition 99 - Not Applicable Syntax Integer Access Read-only Array Disk Drive Write Cache Name arrayDiskDriveWriteCache Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.43 Storage Management Group 621 Name arrayDiskDriveWriteCache Description Indicates the drive write cache capability for PCIe SSD devices. Possible Values: 1 - Enabled 0 - Disabled 99 - Undetermined/NotApplicable Syntax Integer Access Read-only Array Disk Model Number Name arrayDiskModelNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.44 Description Provides the PCIe SSD device model number. Syntax DisplayString Access Read-only Array Disk Life Remaining Name arrayDiskLifeRemaining Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.45 Description Provides the PCIe SSD device life remaining in percentage. Possible Values: 0..100, 999 - Undetermined/Not Applicable Syntax Integer (0..100) Access Read-only Array Disk Driver Version Name arrayDiskDriverVersion Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.46 Description Provides the PCIe SSD device driver version. Syntax Integer Access Read-only 622 Storage Management Group Array Disk Device Life Status Name arrayDiskDeviceLifeStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.47 Description Provides the PCIe SSD device life status. Possible Values: -1: Not Available / Not Applicable 1: Drive Health Good 2: Approaching Warranty Coverage Expiry 3: Warranty Coverage Expired 4: Approaching Read Only 5: Read Only Syntax Integer Access Read-only Array Disk Enclosure Connection Table This section describes the connections among array disks, their enclosure, and their associated controller. For each object in the table, its object number corresponds to an instance number in the appropriate MIB table for that object where all of the object properties can be found. NOTE: Only array disks that are part of an enclosure are listed in this table. Backplanes are considered enclosures by Storage Management. The following object sets up the Array Disk Enclosure Connection Table. Name arrayDiskEnclosureConnectionTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.5 Description Defines the array disk enclosure connection table. Syntax SEQUENCE OF ArrayDiskEnclosureConnectionEntry Access Not accessible Storage Management Group 623 Array Disk Enclosure Connection Entry Name arrayDiskEnclosureConnectionEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.5.1 Description Defines the array disk enclosure connection table entry. Syntax ArrayDiskEnclosureConnectionEntry Access Not accessible Index arrayDiskEnclosureConnectionNumber Array Disk Enclosure Connection Number Name arrayDiskEnclosureConnectionNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.5.1.1 Description Identifies the instance number of the array disk enclosure connection entry. Syntax Integer Access Read-only Array Disk Enclosure Connection Array Disk Name Name arrayDiskEnclosureConnectionArrayDiskName Object ID 1.3.6.1.4.1.674.10893.1.20.130.5.1.2 Description Identifies the name of the array disk in the connection as represented in Storage Management. Syntax DisplayString Access Read-only Array Disk Enclosure Connection Array Disk Number Name arrayDiskEnclosureConnectionArrayDiskNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.5.1.3 Description Identifies the instance number of the array disk in the arrayDiskTable in this connection. Syntax Integer 624 Storage Management Group Name arrayDiskEnclosureConnectionArrayDiskNumber Access Read-only Array Disk Enclosure Connection Enclosure Name Name arrayDiskEnclosureConnectionEnclosureName Object ID 1.3.6.1.4.1.674.10893.1.20.130.5.1.4 Description Identifies the name of the enclosure as represented in Storage Management to which this array disk belongs. Syntax DisplayString Access Read-only Array Disk Enclosure Connection Enclosure Number Name arrayDiskEnclosureConnectionEnclosureNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.5.1.5 Description Identifies the instance number in the enclosureTable of the enclosure to which this array disk belongs. Syntax Integer Access Read-only Array Disk Enclosure Connection Controller Name Name arrayDiskEnclosureConnectionControllerName Object ID 1.3.6.1.4.1.674.10893.1.20.130.5.1.6 Description Identifies the name of the controller as represented in Storage Management to which this array disk is connected. Syntax DisplayString Access Read-only Array Disk Enclosure Connection Controller Number Name arrayDiskEnclosureConnectionControllerNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.5.1.7 Storage Management Group 625 Name arrayDiskEnclosureConnectionControllerNumber Description Identifies the instance number in the controllerTable of the controller to which this array disk is connected. Syntax Integer Access Read-only Array Disk Channel Connection Table This section describes the connections between array disks, their channel, and their associated controller. For each object in the table, its object number corresponds to an instance number in the appropriate MIB table for that object where all of the object properties can be found. NOTE: Only array disks that are NOT part of an enclosure are listed in this table. Backplanes are considered enclosures by Storage Management. The following object sets up the Array Disk Channel Connection Table. Name arrayDiskChannelConnectionTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.6 Description Defines the array disk channel connection table. Syntax SEQUENCE OF ArrayDiskChannelConnectionEntry Access Not accessible Array Disk Channel Connection Entry Name arrayDiskChannelConnectionEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.6.1 Description Defines the array disk channel connection table entry. Syntax ArrayDiskChannelConnectionEntry Access Not accessible Index arrayDiskEnclosureConnectionNumber Array Disk Channel Connection Number Name arrayDiskChannelConnectionNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.6.1.1 626 Storage Management Group Name arrayDiskChannelConnectionNumber Description Identifies the instance number of the array disk channel connection entry. Syntax Integer Access Read-only Array Disk Channel Connection Array Disk Name Name arrayDiskChannelConnectionArrayDiskName Object ID 1.3.6.1.4.1.674.10893.1.20.130.6.1.2 Description Identifies the name of the array disk in the connection as represented in Storage Management. Syntax DisplayString Access Read-only Array Disk Channel Connection Array Disk Number Name arrayDiskChannelConnectionArrayDiskNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.6.1.3 Description Identifies the instance number of the array disk in the arrayDiskTable in the connection. Syntax Integer Access Read-only Array Disk Channel Connection Channel Name Name arrayDiskChannelConnectionChannelName Object ID 1.3.6.1.4.1.674.10893.1.20.130.6.1.4 Description Identifies the name of the channel as represented in Storage Management to which the array disk is connected. Syntax DisplayString Access Read-only Storage Management Group 627 Array Disk Channel Connection Channel Number Name arrayDiskChannelConnectionChannelNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.6.1.5 Description Identifies the instance number of the channel in the channelTable to which the array disk is connected. Syntax Integer Access Read-only Array Disk Channel Connection Controller Name Name arrayDiskChannelConnectionControllerName Object ID 1.3.6.1.4.1.674.10893.1.20.130.6.1.6 Description Identifies the name of the controller as represented in Storage Management to which the array disk is connected. Syntax DisplayString Access Read-only Array Disk Channel Connection Controller Number Name arrayDiskChannelConnectionControllerNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.6.1.7 Description Identifies the instance number in the controllerTable of the controller to which the array disk is connected. Syntax Integer Access Read-only Fan Table This section describes available properties for each fan on the managed system. The following object sets up the Fan Table. Name fanTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.7 Description Defines the fan table. 628 Storage Management Group Name fanTable Syntax SEQUENCE OF FanEntry Access Not accessible Fan Entry Name fanEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1 Description Defines the fan table entry. Syntax FanEntry Access Not accessible Index fanNumber Fan Number Name fanNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.1 Description Identifies the instance number of the fan entry. Syntax Integer Access Read-only Fan Name Name Fan Name Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.2 Description Identifies the fan's name as represented in Storage Management. Syntax DisplayString Access Read-only Fan Vendor Name fanVendor Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.3 Storage Management Group 629 Name fanVendor Description Identifies the fan's (re)seller's name. Syntax DisplayString Access Read-only 630 Storage Management Group Fan State Name fanState Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.4 Description Identifies the current state of the fan. Possible states: 0: Unknown 1: Ready 2: Failed 3: Online 4: Offline 6: Degraded 21: Missing Syntax Integer Access Read-only Fan Severity Name fanSeverity Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.5 Description This entry is obsolete for Storage Management. It is replaced with RollUpStatus and ComponentStatus for each device. Syntax Integer Access Read-only Fan Probe Unit Name fanProbeUnit Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.6 Description This entry is obsolete for Storage Services. Syntax DisplayString Access Read-only Storage Management Group 631 Fan Probe Minimum Warning Name fanProbeMinimumWarning Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.7 Description This entry is obsolete. This setting is not supported by fans managed under Storage Management. Syntax DisplayString Access Read-only Fan Probe Minimum Critical Name fanProbeMinimumCritical Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.8 Description This entry is obsolete. This setting is not supported by fans managed under Storage Management. Syntax DisplayString Access Read-only Fan Probe Maximum Warning Name fanProbeMaximumWarning Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.9 Description This entry is obsolete. This setting is not supported by fans managed under Storage Management. Syntax DisplayString Access Read-only Fan Probe Maximum Critical Name fanProbeMaximumCritical Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.10 Description This entry is obsolete. This setting is not supported by fans managed under Storage Management. Syntax DisplayString Access Read-only 632 Storage Management Group Fan Probe Current Value Name fanProbeCurrValue Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.11 Description Identifies the current speed of the fan. Syntax DisplayString Access Read-only Fan1 Part Number Name fan1PartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.12 Description Identifies the part number of the fan in the enclosure. Syntax DisplayString Access Read-only Fan 2 Part Number Name fan2PartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.13 Description This entry is obsolete. This setting is not supported by fans managed under Storage Management. Syntax DisplayString Access Read-only Storage Management Group 633 Fan Roll-Up Status Name fanRollUpStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.14 Description Severity of the fan state. This is the combined status of the fan and its components. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Fan Component Status Name fanComponentStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.15 Description The status of the fan itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only 634 Storage Management Group Fan Nexus ID Name fanNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.16 Description Durable unique ID for the fan. Syntax DisplayString Access Read-only Fan Revision Name fanRevision Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.17 Description Indicates the revision number of the fan in the enclosure. Syntax DisplayString Access Read-only Fan Connection Table This section describes the connection between each fan on the managed system and its enclosure. Each enclosure number in the table corresponds to that enclosure instance in the enclosure Table. The following object sets up the Fan Connection Table. Name fanConnectionTable Object ID fanConnectionTable Description Defines the fan connection table. Syntax SEQUENCE OF FanConnectionEntry Access Not accessible Fan Connection Entry Name fanConnectionEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.8.1 Description Defines the fan connection table entry. Storage Management Group 635 Name fanConnectionEntry Syntax FanConnectionEntry Access Not accessible Index fanConnectionNumber Fan Connection Number Name fanConnectionNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.8.1.1 Description Identifies the instance number of the fan connection entry. Syntax Integer Access Read-only Fan Connection Fan Name Name fanConnectionFanName Object ID 1.3.6.1.4.1.674.10893.1.20.130.8.1.2 Description Identifies the name of the fan in the connection as represented in Storage Management. Syntax DisplayString Access Read-only Fan Connection Fan Number Name fanConnectionFanNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.8.1.3 Description Identifies the instance number of the fan in the fanTable in the connection. Syntax Integer Access Read-only 636 Storage Management Group Fan Connection Enclosure Name Name fanConnectionEnclosureName Object ID 1.3.6.1.4.1.674.10893.1.20.130.8.1.4 Description Identifies the name of the enclosure as represented in Storage Management to which the fan belongs. Syntax DisplayString Access Read-only Fan Connection Enclosure Number Name fanConnectionEnclosureNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.8.1.5 Description Identifies the instance number of the enclosure in the enclosureTable to which the fan belongs. Syntax Integer Access Read-only Power Supply Table This section describes available properties for each power supply on the managed system. The following object sets up the Power Supply Table. Name powerSupplyTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.9 Description Defines the power supply table. Syntax SEQUENCE OF PowerSupplyEntry Access Not accessible Storage Management Group 637 Power Supply Entry Name powerSupplyEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1 Description Defines the power supply table entry. Syntax PowerSupplyEntry Access Not accessible Index powerSupplyNumber Power Supply Number Name powerSupplyNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.1 Description Identifies the instance number of the power supply entry. Syntax Integer Access Read-only Power Supply Name Name powerSupplyName Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.2 Description Identifies the power supply's name as represented in Storage Management. Syntax DisplayString Access Read-only Power Supply Vendor Name powerSupplyVendor Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.3 Description Identifies the power supply's (re)seller's name. Syntax DisplayString Access Read-only 638 Storage Management Group Power Supply State Name powerSupplyState Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.4 Description Identifies the current state of the power supply. Possible states: 0: Unknown 1: Ready 2: Failed 5: Not Installed 6: Degraded 11: Removed Syntax Integer Access Read-only Power Supply Severity Name powerSupplySeverity Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.5 Description This entry is obsolete for Storage Management. It is replaced with RollUpStatus and ComponentStatus for each device. Syntax Integer Access Read-only Power Supply 1 Part Number Name powerSupply1PartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.6 Description Identifies the part number of the power supply of the enclosure. Syntax DisplayString Access Read-only Storage Management Group 639 Power Supply 2 Part Number Name powerSupply2PartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.7 Description This entry is obsolete. This setting is not supported by power supplies managed under Storage Management Syntax DisplayString Access Read-only Power Supply Roll-Up Status Name powerSupplyRollUpStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.8 Description Identifies the severity of the power supply state. This is the combined status of the power supply and its components. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only 640 Storage Management Group Power Supply Component Status Name powerSupplyComponentStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.9 Description Severity of the power supply state. This is the combined status of the power supply and its components. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Power Supply NexusID Name powerSupplyNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.10 Description Durable unique ID for the power supply. Syntax DisplayString Access Read-only Power Supply Revision Name powerSupplyRevision Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.11 Description Indicates the revision number of the power supply in the enclosure. Syntax DisplayString Access Read-only Storage Management Group 641 Power Supply Connection Table This section describes the connection between each power supply on the managed system and its enclosure. Each enclosure number in the table corresponds to that enclosure instance in the enclosure Table. The following object sets up the Power Supply Connection Table. Name powerSupplyConnectionTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.10 Description Defines the power supply connection table. Syntax SEQUENCE OF PowerSupplyConnectionEntry Access Not accessible Power Supply Connection Entry Name powerSupplyConnectionEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.10.1 Description Defines the power supply connection table entry. Syntax PowerSupplyConnectionEntry Access Not accessible Index powerSupplyConnectionNumber Power Supply Connection Number Name powerSupplyConnectionNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.10.1.1 Description Identifies the instance number of the power supply connection entry. Syntax Integer Access Read-only 642 Storage Management Group Power Supply Connection Power Supply Name Name powerSupplyConnectionPowerSupplyName Object ID 1.3.6.1.4.1.674.10893.1.20.130.10.1.2 Description Identifies the name of the power supply in the connection as represented in Storage Management. Syntax DisplayString Access Read-only Power Supply Connection Power Supply Number Name powerSupplyConnectionPowerSupplyNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.10.1.3 Description Identifies the instance number of the power supply in the powerSupplyTable in the connection. Syntax Integer Access Read-only Power Supply Connection Enclosure Name Name powerSupplyConnectionEnclosureName Object ID 1.3.6.1.4.1.674.10893.1.20.130.10.1.4 Description Identifies the name of the enclosure as represented in Storage Management to which the power supply belongs. Syntax DisplayString Access Read-only Power Supply Connection Enclosure Number Name powerSupplyConnectionEnclosureNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.10.1.5 Description Identifies the instance number of the enclosure in the enclosureTable to which the power supply belongs. Syntax Integer Access Read-only Storage Management Group 643 Power Supply Connection Firmware Version Name powerSupplyConnectionFirmwareVersion Object ID 1.3.6.1.4.1.674.10893.1.20.130.10.1.6 Description Displays power supply connection firmware version. NOTE: Available above 1.04 firmware version. Syntax DisplayString Access Read-only Temperature Probe Table This section describes available properties for each temperature probe on the managed system. The following object sets up the Temperature Probe Table. Name temperatureProbeTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.11 Description A table of managed temperature probes. The number of entries is related to the number of temperature probes discovered in the system. The maximum number of entries is implementation dependent. NOTE: The properties in this table may not be applicable to all entries. Syntax SEQUENCE OF TemperatureProbeEntry Access Not accessible Temperature Probe Entry Name temperatureProbeEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1 Description Defines the Temperature Probe Table. A row in this table cannot be created or deleted by SNMP operations on columns of the table. Syntax TemperatureProbeEntry 644 Storage Management Group Name temperatureProbeEntry Access Not accessible Index TemperatureProbeNumber Temperature Probe Number Name temperatureProbeNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.1 Description Identifies the instance number of the temperature probe entry. Syntax Integer Access Read-only Temperature Probe Name Name temperatureProbeName Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.2 Description Identifies the temperature probe's name as represented in Storage Management. Syntax DisplayString Access Read-only Temperature Probe Vendor Name temperatureProbeVendor Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.3 Description Identifies the temperature probe's (re)seller's name. Syntax DisplayString Access Read-only Temperature Probe State Name temperatureProbeState Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.4 Storage Management Group 645 Name temperatureProbeState Description Identifies the current state of the temperature probe. Possible states: 0: Unknown 1: Ready 2: Failed (Minimum Failure Threshold Exceeded, Maximum Failure Threshold Exceeded) 4: Offline 6: Degraded (Minimum Warning Threshold Exceeded, Maximum Warning Threshold Exceeded) 9: Inactive 21: Missing Syntax Integer Access Read-only Temperature Probe Severity Name temperatureProbeSeverity Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.5 Description This entry is obsolete for Storage Management. It is replaced with RollUpStatus and ComponentStatus for each device. Syntax Integer Access Read-only Temperature Probe Unit Name temperatureProbeUnit Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.6 Description Identifies the units that are used to display temperatures for the temperature probe. Syntax DisplayString Access Read-only 646 Storage Management Group Temperature Probe Minimum Warning Name temperatureProbeMinWarning Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.7 Description Identifies the minimum temperature that forces the probe into a warning state. Syntax Integer Access Read-only Temperature Probe Minimum Critical Name temperatureProbeMinCritical Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.8 Description Identifies the minimum temperature that forces the probe into an error state. Syntax Integer Access Read-only Temperature Probe Maximum Warning Name temperatureProbeMaxWarning Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.9 Description Identifies the maximum temperature that forces the probe into a warning state. Syntax Integer Access Read-only Temperature Probe Maximum Critical Name temperatureProbeMaxCritical Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.10 Description Identifies the maximum temperature that forces the probe into an error state. Syntax Integer Storage Management Group 647 Name temperatureProbeMaxCritical Access Read-only Temperature Probe Current Value Name temperatureProbeCurValue Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.11 Description Identifies the current temperature of the probe. Syntax Integer Access Read-only 648 Storage Management Group Temperature Probe Roll-Up Status Name temperatureProbeRollUpStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.12 Description Identifies the severity of the temperature probe state. This is the combined status of the temperature probe and its components. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Temperature Probe Component Status Name temperatureProbeComponentStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.13 Description Identifies the status of the temperature probe itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Storage Management Group 649 Temperature Probe Nexus ID Name temperatureProbeNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.14 Description Displays the durable unique ID for this temperature probe. Syntax DisplayString Access Read-only Temperature Probe Connection Table This section describes the connection between each temperature probe on the managed system and its enclosure. Each enclosure number in the table corresponds to that enclosure instance in the enclosure Table. The following object sets up the Temperature Probe Connection Table. Name temperatureConnectionTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.12 Description Defines the temperature probe connection table. Syntax SEQUENCE OF TemperatureConnectionEntry Access Not accessible Temperature Probe Connection Entry Name temperatureConnectionEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.12.1 Description Defines the temperature probe connection table entry. Syntax TemperatureConnectionEntry Access Not accessible Index temperatureConnectionNumber 650 Storage Management Group Temperature Probe Connection Number Name temperatureConnectionNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.12.1.1 Description Identifies the instance number of the temperature probe connection entry. Syntax Integer Access Read-only Temperature Probe Connection Temperature Probe Name Name temperatureConnectionTemperatureName Object ID 1.3.6.1.4.1.674.10893.1.20.130.12.1.2 Description Identifies the name of the temperature probe in the connection as represented in Storage Management. Syntax DisplayString Access Read-only Temperature Probe Connection Temperature Probe Number Name temperatureConnectionTemperatureNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.12.1.3 Description Identifies the instance number in the temperatureTable of the temperature probe in the connection. Syntax Integer Access Read-only Temperature Probe Connection Enclosure Name Name temperatureConnectionEnclosureName Object ID 1.3.6.1.4.1.674.10893.1.20.130.12.1.4 Description Identifies the name of the enclosure as represented in Storage Management to which the temperature probe belongs. Syntax DisplayString Access Read-only Storage Management Group 651 Temperature Probe Connection Enclosure Number Name temperatureConnectionEnclosureNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.12.1.5 Description Identifies the instance number of the enclosure in the enclosureTable to which the temperature probe belongs. Syntax Integer Access Read-only Enclosure Management Module Table This section describes available properties for each enclosure management module on the managed system. The following object sets up the Enclosure Management Module Table. Name enclosureManagementModuleTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.13 Description Defines the enclosure management module table. Syntax SEQUENCE OF EnclosureManagementModuleEntry Access Not accessible Enclosure Management Module Entry Name EnclosureManagementModuleEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1 Description Defines the enclosure management module table entry. Syntax EnclosureManagementModuleEntry Access Not accessible Index enclosureManagementModuleNumber 652 Storage Management Group Enclosure Management Module Number Name enclosureManagementModuleNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.1 Description Identifies the instance number of the enclosure management module entry. Syntax Integer Access Read-only Enclosure Management Module Name Name enclosureManagementModuleName Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.2 Description Identifies the enclosure management module's name as represented in Storage Management. Syntax DisplayString Access Read-only Enclosure Management Module Vendor Name enclosureManagementModuleVendor Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.3 Description Identifies the enclosure management module's (re)seller's name. Syntax DisplayString Access Read-only Storage Management Group 653 Enclosure Management Module State Name enclosureManagementModuleState Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.4 Description Identifies the current state of the enclosure management module. Possible states: 0: Unknown 1: Ready 2: Failed 3: Online 4: Offline 5: Not Installed 6: Degraded 21: Missing Syntax Integer Access Read-only Enclosure Management Module Severity Name enclosureManagementModuleSeverity Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.5 Description This entry is obsolete for Storage Management. It is replaced with RollUpStatus and ComponentStatus for each device. Syntax Integer Access Read-only Enclosure Management Module Part Number Name enclosureManagementModulePartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.6 Description Identifies the part number of the enclosure memory module. Syntax Display String Access Read-only 654 Storage Management Group Enclosure Management Module Type Name enclosureManagementModuleType Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.7 Description Identifies the type of enclosure management module. Possible values: 0: Unknown 1: EMM 2: Termination Card Syntax Integer Access Read-only Enclosure Management Module Firmware Version Name enclosureManagementModuleFWVersion Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.8 Description Identifies the firmware version of the enclosure memory module. Syntax DisplayString Access Read-only Enclosure Management Module Maximum Speed Name enclosureManagementModuleMaxSpeed Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.9 Description Identifies the maximum bus speed of the enclosure management module. Syntax DisplayString Access Read-only Storage Management Group 655 Enclosure Management Module Roll-Up Status Name enclosureManagementModuleRollUpStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.10 Description Identifies the severity of the enclosure management module state. This is the combined status of the EMM and its components. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Enclosure Management Module Component Status Name enclosureManagementModuleComponentStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.11 Description Identifies the status of the enclosure management module itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only 656 Storage Management Group Enclosure Management Module Nexus ID Name enclosureManagementModuleNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.12 Description Displays the durable unique ID for this EMM. Syntax DisplayString Access Read-only Enclosure Management Module Revision Name enclosureManagementModuleRevision Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.13 Description Identifies the revision number of the enclosure management module. Syntax DisplayString Access Read-only Enclosure Management Module Connection Table This section describes the connection between each enclosure management module on the managed system and its enclosure. Each enclosure number in the table corresponds to that enclosure instance in the enclosure Table. The following object sets up the Enclosure Management Module Connection Table. Name enclosureManagementModuleConnectionTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.14 Description Defines the enclosure memory module connection table. Syntax SEQUENCE OF EnclosureManagementModuleConnectionEntry Access Not accessible Storage Management Group 657 Enclosure Management Module Connection Entry Name enclosureManagementModuleConnectionEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.14.1 Description Defines the enclosure memory module connection table entry. Syntax EnclosureManagementModuleConnectionEntry Access Not accessible Index enclosureManagementModuleConnectionNumber Enclosure Management Module Connection Number Name enclosureManagementModuleConnectionNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.14.1.1 Description Identifies the instance number of the enclosure memory module connection entry. Syntax Integer Access Read-only Enclosure Management Module Connection EMM Name Name enclosureManagementModuleConnectionEMMName Object ID 1.3.6.1.4.1.674.10893.1.20.130.14.1.2 Description Identifies the name of the enclosure memory module in the connection as represented in Storage Management. Syntax DisplayString Access Read-only 658 Storage Management Group Enclosure Management Module Connection EMM Number Name enclosureManagementModuleConnectionEMMNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.14.1.3 Description Identifies the instance number in the enclosureManagementModuleTable of the enclosure memory module in the connection. Syntax Integer Access Read-only Enclosure Management Module Connection Enclosure Name Name enclosureManagementModuleConnectionEnclosureName Object ID 1.3.6.1.4.1.674.10893.1.20.130.14.1.4 Description Identifies the name of the enclosure as represented in Storage Management to which the enclosure memory module belongs. Syntax DisplayString Access Read-only Enclosure Management Module Connection Enclosure Number Name enclosureManagementModuleConnectionEnclosure Number Object ID 1.3.6.1.4.1.674.10893.1.20.130.14.1.5 Description Identifies the instance number of the enclosure in the enclosureTable to which the enclosure memory module belongs. Syntax Integer Access Read-only Storage Management Group 659 Battery Table This section describes available properties for each controller battery on the managed system. The following object sets up the Battery Table. Name batteryTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.15 Description Defines the battery table. Syntax SEQUENCE OF BatteryEntry Access Not accessible Battery Entry Name batteryEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1 Description Defines the battery table entry. Syntax BatteryEntry Access Not accessible Index batteryNumber Battery Number Name batteryNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.1 Description Identifies the instance number of the battery entry. Syntax Integer Access Read-only 660 Storage Management Group Battery Name Name batteryName Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.2 Description Identifies the battery's name as represented in Storage Management. Syntax DisplayString Access Read-only Battery Vendor Name batteryVendor Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.3 Description Identifies the battery's (re)seller's name. Syntax DisplayString Access Read-only Battery State Name batteryState Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.4 Description Identifies the current state of battery. Possible values: 0: Unknown 1: OK 2: Failed 6: Degraded 7: Reconditioning 9: High 10: Low 12: Charging 21: Missing 36: Learning Syntax Integer Access Read-only Storage Management Group 661 Battery Roll-Up Status Name batteryRollUpStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.5 Description Identifies the severity of the battery state. This is the combined status of the battery and its components. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Battery Component Status Name batteryComponentStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.6 Description Identifies the status of the battery itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only 662 Storage Management Group Battery Charge Count Name batteryChargeCount Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.7 Description Identifies the number of charges that have been applied to the battery. Syntax Integer Access Read-only Battery Max Charge Count Name batteryMaxChargeCount Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.8 Description Identifies the maximum number of charges that can be applied to the battery. Syntax Integer Access Read-only Battery Nexus ID Name batteryNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.9 Description Displays the durable unique ID for this EMM. Syntax DisplayString Access Read-only Storage Management Group 663 Battery Predicted Capacity Name batteryPredictedCapacity Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.10 Description Displays the battery's ability to be charged. Possible values: 1: Failed - The battery cannot be charged and needs to be replaced. 2: Ready - The battery can be charged to full capacity. 4: Unknown - The battery is completing a Learn cycle. The charge capacity of the battery cannot be determined until the Learn cycle is complete. Syntax Integer Access Read-only Battery Next Learn Time Name batteryNextLearnTime Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.11 Description Indicates the time (in hours) the next learn cycle must be executed. Syntax Integer Access Read-only 664 Storage Management Group Battery Learn State Name batteryLearnState Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.12 Description Specifies the learn state activity of the battery. Possible values: 1: Failed 2: Active 4: Timed out 8: Requested 16: Idle 32: Due Syntax Integer Access Read-only Battery ID Name batteryID Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.13 Description Represents the unique id for the battery. Syntax Integer Access Read-only Battery Maximum Learn Delay Name batteryMaxLearnDelay Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.14 Description The maximum amount of time (in hours) that the battery learn cycle can be delayed. Syntax Integer Access Read-only Storage Management Group 665 Battery Learn Mode Name batteryLearnMode Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.15 Description Indicates the current learn mode of the battery. Possible values: 1: Auto 2: Warn 4: Autowarn 8: Unknown Syntax Integer Access Read-only 666 Storage Management Group Battery Connection Table This section describes the connection between each controller battery on the managed system and its controller. Each controller number in the table corresponds to that controller instance in the controller Table. The following object sets up the Battery Connection Table. Name batteryConnectionTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.16 Description Defines the battery connection table. Syntax SEQUENCE OF BatteryConnectionEntry Access Not accessible Battery Connection Entry Name batteryConnectionEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.16.1 Description Defines the battery connection table entry. Syntax BatteryConnectionEntry Access BatteryConnectionEntry Index BatteryConnectionNumber Battery Connection Number Name batteryConnectionNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.16.1.1 Description Identifies the instance number of the battery connection entry. Syntax Integer Access Read-only Storage Management Group 667 Battery Connection Battery Name Name batteryConnectionBatteryName Object ID 1.3.6.1.4.1.674.10893.1.20.130.16.1.2 Description Identifies the name of the battery in the connection as represented in Storage Management. Syntax DisplayString Access Read-only Battery Connection Battery Number Name batteryConnectionBatteryNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.16.1.3 Description Identifies the instance number in the batteryTable of the battery in the connection. Syntax Integer Access Read-only Battery Connection Controller Name Name batteryConnectionControllerName Object ID 1.3.6.1.4.1.674.10893.1.20.130.16.1.4 Description Identifies the name of the controller as represented in Storage Management to which the battery belongs. Syntax DisplayString Access Read-only Battery Connection Controller Number Name batteryConnectionControllerNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.16.1.5 Description Identifies instance number of the controller in the controllerTable to which this battery belongs. Syntax Integer Access Read-only 668 Storage Management Group Logical Devices Group The Logical Devices Management Information Base (MIB) group provides information about the logical devices managed by the Dell Storage Management Software and their relationships to each other. This group and all of its associated tables and objects are not supported on Microsoft Windows Advanced Server Limited Edition 64-bit operating system (Windows.Net-64) on a Dell PowerEdge 7150. The following MIB tables define objects and relationships, or connections among the objects, in the Logical Devices Group: • Virtual Disk Table—describes available properties for each virtual disk on the managed system. • Array Disk Logical Connection Table—describes the connections between array disks, the virtual disk to which they belong, and their associated logical disk. For each object in the table, its object number corresponds to an instance number in the appropriate MIB table for that object where all of the object properties can be found. Virtual Disk Table This section describes available properties for each virtual disk on the managed system. The following object sets up the Virtual Disk Table. Name virtualDiskTable Object ID 1.3.6.1.4.1.674.10893.1.20.140.1 Description Defines the virtual disk table. Syntax SEQUENCE OF VirtualDiskEntry Access Not accessible Storage Management Group 669 Virtual Disk Entry Name virtualDiskEntry Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1 Description Defines the virtual disk table entry. Syntax VirtualDiskEntry Access Not accessible Index virtualDiskNumber Virtual Disk Number Name virtualDiskNumber Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.1 Description Identifies the instance number of the virtual disk entry. Syntax Integer Access Read-only Virtual Disk Name Name virtualDiskName Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.2 Description Identifies the virtual disk's label generated by Storage Management or entered by the user. Syntax DisplayString Access Read-only Virtual Device Disk Name Name virtualDiskDeviceName Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.3 Description Identifies the device name used by the virtual disk's member disks. Syntax DisplayString Access Read-only 670 Storage Management Group Virtual Disk State Name virtualDiskState Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.4 Description Identifies the current state of the virtual disk. Possible states: 0: Unknown 1: Ready - The disk is accessible and has no known problems. 2: Failed - The data on the virtual disk is no longer fault tolerant because one of the underlying disks is not online. 3: Online 4: Offline - The disk is not accessible. The disk may be corrupted or intermittently unavailable. 6: Degraded - The data on the virtual disk is no longer fault tolerant because one of the underlying disks is not online. 15: Resynching 16: Regenerating 24: Rebuilding 26: Formatting 32: Reconstructing 35: Initializing 36: Background Initialization 38: Resynching Paused 52: Permanently Degraded 54: Degraded Redundancy Syntax Integer Access Read-only Storage Management Group 671 Virtual Disk Severity Name virtualDiskSeverity Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.5 Description This entry is obsolete for Storage Management. It is replaced with RollUpStatus and ComponentStatus for each device. Syntax Integer Access Read-only Virtual Disk Length in Megabytes Name virtualDiskLengthInMB Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.6 Description Identifies the size of this virtual disk in megabytes. If the size is 0, the size is smaller than a megabyte. Syntax Integer Access Read-only Virtual Disk Length in Bytes Name virtualDiskLengthBytes Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.7 Description Identifies the portion of the virtual disk in bytes that is smaller than a megabyte. This size plus the virtualDiskLengthInMB is the total size of the virtual disk. Syntax Integer Access Read-only 672 Storage Management Group Virtual Disk Free Space in Megabytes Name virtualDiskFreeSpaceInMB Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.8 Description This entry is obsolete. This property is not supported by virtual disks managed under Storage Management. Syntax Integer Access Read-only Virtual Disk Free Space in Bytes Name virtualDiskFreeSpaceInBytes Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.9 Description This entry is obsolete. This property is not supported by virtual disks managed under Storage Management. Syntax Integer Access Read-only Virtual Disk Write Policy Name virtualDiskWritePolicy Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.10 Description Indicates whether the controller's write cache is used when writing to a virtual disk. Possible values: 1: Enabled - Adaptec Write Cache Enabled Protected 2: Disabled - Adaptec Write Cache Disabled 3: LSI Write Back 4: LSI Write Through 5: Enabled Always (Adaptec only) 6: Enabled Always (SAS only) 9: Not Applicable Syntax Integer Access Read-only Storage Management Group 673 Virtual Disk Read Policy Name virtualDiskReadPolicy Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.11 Description Indicates whether the controller's read cache is used when reading from a virtual disk. Possible values: 1: Enabled - Adaptec Read Cache Enabled 2: Disabled - Adaptec Read Cache Disabled 3: LSI Read Ahead 4: LSI Adaptive Read Ahead 5: LSI No Read Ahead 9: Not Applicable Syntax Integer Access Read-only Virtual Disk Cache Policy Name virtualDiskCachePolicy Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.12 Description Indicates whether the controller's cache is used when reading from or writing to a virtual disk. Possible values: 1: Direct I/O (LSI) 2: Cached I/O (LSI) 99: Not Applicable Syntax Integer Access Read-only 674 Storage Management Group Virtual Disk Layout Name virtualDiskLayout Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.13 Description Indicates the virtual disk's RAID type. Possible values: 1: Concatenated 2: RAID-0 3: RAID-1 7: RAID-5 8: RAID-6 10: RAID-10 12: RAID-50 19: Concatenated RAID 1 24: RAID-60 25: CacheCade Syntax Integer Access Read-only Virtual Disk Current Stripe Size in Megabytes Name virtualDiskCurStripeSizeInMB Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.14 Description Identifies the stripe size of the virtual disk in megabytes. If this size is 0, the stripe size is smaller than a megabyte. Syntax Integer Access Read-only Storage Management Group 675 Virtual Disk Current Stripe Size in Bytes Name virtualDiskCurStripeSizeInBytes Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.15 Description Identifies the portion of the stripe size in bytes that is smaller than a megabyte. This size plus the virtualDiskCurStripeSizeInMB is the total stripe size on the virtual disk. Syntax Integer Access Read-only Virtual Disk Channel Name virtualDiskChannel Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.16 Description This entry is obsolete. This property is not supported by virtual disks managed under Storage Management. Syntax Integer Access Read-only Virtual Disk Target ID Name virtualDiskTargetID Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.17 Description Displays the unique ID for the virtual disk. Syntax Integer Access Read-only Virtual Disk LUN ID Name virtualDiskLunID Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.18 Description This entry is obsolete. This property is not supported by virtual disks managed under Storage Management. Syntax Integer Access Read-only 676 Storage Management Group Virtual Disk Roll-Up Status Name virtualDiskRollUpStatus Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.19 Description Identifies the severity of the virtual disk state. This is the combined status of the virtual disk and its components. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Virtual Disk Component Status Name virtualDiskComponentStatus Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.20 Description Displays the status of the virtual disk itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Storage Management Group 677 Virtual Disk Nexus ID Name virtualDiskNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.21 Description Displays the durable unique ID for the virtual disk. Syntax DisplayString Access Read-only Virtual Disk Array Disk Type Name virtualDiskArrayDiskType Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.22 Description Identifies the type of array (physical) disks used to create the virtual disk. Possible values: 1: SAS 2: SATA 3: SCSI 4: IDE 99: Unknown Syntax Integer Access Read-only Virtual Disk Bad Blocks Detected Name virtualDiskBadBlocksDetected Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.23 Description Indicates if virtual disk has bad blocks. Possible values: 0 - No 1 - Yes 2 - Not Applicable 99 - Unknown 678 Storage Management Group Name virtualDiskBadBlocksDetected Syntax Integer Access Read-only Virtual Disk Encrypted Name virtualDiskEncrypted Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.24 Description Indicates if virtual disk is encrypted. Possible values: 0 - No 1 - Yes 99 - Unknown Syntax Integer Access Read-only Virtual Disk is CacheCade Name virtualDiskIsCacheCade Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.25 Description Indicates if this virtual disk is configured as CacheCade. Possible values: 1 - Yes 0 - No 99 - Undetermined Syntax Integer Access Read-only Virtual Disk Disk Cache Policy Name virtualDiskDiskCachePolicy Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.26 Storage Management Group 679 Name virtualDiskDiskCachePolicy Description Indicates disk cache policy of the logical device. Value: 1 - Enabled, 2 - Disabled, 99 - Undetermined Syntax Integer Access Read-only Array Disk Logical Connection Table This section describes the connections between array disks, the virtual disk to which they belong, and their associated logical disk. For each object in the table, its object number corresponds to an instance number in the appropriate MIB table for that object where all of the object properties can be found. The following object sets up the Array Disk Logical Connection Table. Name arrayDiskLogicalConnectionTable Object ID 1.3.6.1.4.1.674.10893.1.20.140.3 Description Defines the array disk logical connection table. Syntax SEQUENCE OF arrayDiskLogicalConnectionEntry Access Not accessible Array Disk Logical Connection Entry Name arrayDiskLogicalConnectionEntry Object ID 1.3.6.1.4.1.674.10893.1.20.140.3.1 Description Defines the array disk logical connection table entry. Syntax ArrayDiskLogicalConnectionEntry Access Not accessible Index arrayDiskLogicalConnectionNumber Array Disk Logical Connection Number Name arrayDiskLogicalConnectionNumber Object ID 1.3.6.1.4.1.674.10893.1.20.140.3.1.1 680 Storage Management Group Name arrayDiskLogicalConnectionNumber Description Identifies the instance number of the disk entry. Syntax Integer Access Read-only Array Disk Logical Connection Array Disk Name Name arrayDiskLogicalConnectionArrayDiskName Object ID 1.3.6.1.4.1.674.10893.1.20.140.3.1.2 Description Identifies the name of the array disk in the logical connection. Syntax DisplayString Access Read-only Array Disk Logical Connection Array Disk Number Name arrayDiskLogicalConnectionArrayDiskNumber Object ID 1.3.6.1.4.1.674.10893.1.20.140.3.1.3 Description Identifies the instance number of the array disk in the logical connection. Syntax Integer Access Read-only Array Disk Logical Connection Virtual Disk Name Name arrayDiskLogicalConnectionVirtualDiskName Object ID 1.3.6.1.4.1.674.10893.1.20.140.3.1.4 Description Identifies the name of the virtual disk to which the array disk belongs. Syntax DisplayString Access Read-only Storage Management Group 681 Array Disk Logical Connection Virtual Disk Number Name arrayDiskLogicalConnectionVirtualDiskNumber Object ID 1.3.6.1.4.1.674.10893.1.20.140.3.1.5 Description Identifies the instance number of the virtual disk to which the array disk belongs. Syntax Integer Access Read-only Array Disk Logical Connection Disk Name Name arrayDiskLogicalConnectionDiskName Object ID 1.3.6.1.4.1.674.10893.1.20.140.3.1.6 Description Identifies the name of the disk group to which the array disk belongs. NOTE: This property is currently not supported. Syntax DisplayString Access Read-only Array Disk Logical Connection Disk Number Name arrayDiskLogicalConnectionDiskNumber Object ID 1.3.6.1.4.1.674.10893.1.20.140.3.1.7 Description Identifies the instance number of the disk group to which the array disk belongs. NOTE: This property is currently not supported. Syntax Integer Access Read-only Storage Management Event Group The Storage Management Event Group defines the properties that are sent with SNMP traps. 682 Storage Management Group Message ID Event Name messageIDEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.1 Description Displays the Storage Management event message number. Syntax Integer Access Read-only Description Event Name descriptionEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.2 Description Displays the Storage Management event message text describing the alert. Syntax DisplayString Access Read-only Location Event Name locationEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.3 Description Displays the additional information identifying the location of the object causing the alert. Syntax DisplayString Access Read-only Object Name Event Name objectNameEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.4 Description Displays the name of the object as represented in Storage Management causing the alert. Syntax DisplayString Access Read-only Storage Management Group 683 Object OID Event Name objectOIDEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.5 Description Displays the MIB OID of the object causing the alert. Syntax DisplayString Access Read-only Object Nexus Event Name objectNexusEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.6 Description Displays the durable, unique ID of the object causing the alert. Syntax DisplayString Access Read-only Current Status Event Name currentStatusEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.7 Description Displays the current status of object causing the alert, if applicable. Syntax DellStatus Access Read-only Previous Status Event Name previousStatusEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.8 Description Displays the previous status of the object causing the alert, if applicable. Syntax DellStatus Access Read-only 684 Storage Management Group Change Management Group 25 The Change Management Group lets you monitor information about the Dell devices and software that are present on a particular managed computer chassis. This information is collected during an inventory scan. Inventory Group The following objects describe the fields for inventory information. Inventory Locale Name inventoryLocale Object ID 1.3.6.1.4.1.674.10899.1.1 Description Defines the locale of the system. Syntax DisplayString Access Read-only Inventory Schema Version Name inventorySchemaVersion Object ID 1.3.6.1.4.1.674.10899.1.2 Description Defines the inventory schema implemented by this system. Syntax DisplayString Access Read-only Inventory System ID Name inventorySystemID Object ID 1.3.6.1.4.1.674.10899.1.3 Description Defines the System ID for the system. Syntax SystemID Change Management Group 685 Name inventorySystemID Access Read-only Device Group The Device Group defines information about the devices discovered on the system during an inventory scan. Identifying information includes the Component ID, the Device ID, and the Vendor ID. Device Group Table The following object sets up the Device Group Table. Name deviceTable Object ID 1.3.6.1.4.1.674.10899.1.5 Description Defines the Device Table. Syntax SEQUENCE OF DeviceEntry Access Not accessible Device Entry Name deviceEntry Object ID 1.3.6.1.4.1.674.10899.1.5.1 Description Defines a device entry. Syntax DeviceEntry Access Not accessible Device Index Name deviceIndex Object ID 1.3.6.1.4.1.674.10899.1.5.1.1 Description Defines the unique index for this device. Syntax Unsigned16BitRange Access Read-only 686 Change Management Group Device Component ID Name deviceComponentID Object ID 1.3.6.1.4.1.674.10899.1.5.1.2 Description Defines an optional component ID field for the device. Syntax Integer Access Read-only Device Display String Name deviceDisplayString Object ID 1.3.6.1.4.1.674.10899.1.5.1.3 Description Provides a displayable string that describes the device. Syntax DisplayString Access Read-only Device Vendor ID Name deviceVendorID Object ID 1.3.6.1.4.1.674.10899.1.5.1.4 Description Defines the ID for the vendor supplying the device. Syntax Octet String Access Read-only Device ID Name deviceDeviceID Object ID 1.3.6.1.4.1.674.10899.1.5.1.5 Description Defines the ID for the device. Syntax Octet String Access Read-only Change Management Group 687 Device Sub ID Name deviceSubID Object ID 1.3.6.1.4.1.674.10899.1.5.1.6 Description Provides additional device identification. Syntax Octet String Access Read-only Device Sub Vendor ID Name deviceSubVendorID Object ID 1.3.6.1.4.1.674.10899.1.5.1.7 Description Provides additional vendor identification. Syntax Octet String Access Read-only Application Group NOTE: Dell updateable components such as Basic input/output system (BIOS) and FirmWare (FW) are considered applications. For example, the following would be returned for system BIOS: Application/DisplayString = BIOS Application/Version = A10 The Application Group defines information about the applications discovered on the system during an inventory scan. Identifying information includes the application type, the application version, and the application description. 688 Change Management Group Application Group Table The following object sets up the Application Group Table. Name applicationTable Object ID 1.3.6.1.4.1.674.10899.1.6 Description Defines a table of application information for the system. Syntax SEQUENCE OF ApplicationEntry Access Not accessible Application Entry Name applicationEntry Object ID 1.3.6.1.4.1.674.10899.1.6.1 Description Defines an application entry. Syntax ApplicationEntry Access Read-only Application Index Name applicationIndex Object ID 1.3.6.1.4.1.674.10899.1.6.1.1 Description Defines the unique index for this application. Syntax Unsigned16BitRange Access Read-only Application Device Index Name applicationDeviceIndex Object ID 1.3.6.1.4.1.674.10899.1.6.1.2 Description Defines a cross-index to the device table for the application. Syntax Unsigned16BitRange Access Read-only Change Management Group 689 Application Component Type Name applicationComponentType Object ID 1.3.6.1.4.1.674.10899.1.6.1.3 Description Identifies the type of application reported. Syntax DisplayString Access Read-only Application Version Name applicationVersion Object ID 1.3.6.1.4.1.674.10899.1.6.1.4 Description Identifies the version of the application. Syntax DisplayString Access Read-only Application Display String Name applicationDisplayString Object ID 1.3.6.1.4.1.674.10899.1.6.1.5 Description A user visible display string that describes the application. Syntax DisplayString Access Read-only Application Sub-Component ID Name applicationSubComponentID Object ID 1.3.6.1.4.1.674.10899.1.6.1.6 Description The sub-component ID for the application. This is usually valid on ESM device reporting. Syntax DisplayString Access Read-only 690 Change Management Group Operating System Group The Operating System Group provides status and identifying information about a system’s operating system. Identifying information includes the name, version, and service pack of the installed operating system. The following objects describe the fields for Operating System Group. Operating System Vendor Name operatingSystemVendor Object ID 1.3.6.1.4.1.674.10899.2.1 Description Defines the vendor of the Operating System. Syntax DisplayString Access Read-only Operating System Major Version Name operatingSystemMajorVersion Object ID 1.3.6.1.4.1.674.10899.2.2 Description Defines the major version of the Operating System. Syntax DisplayString Access Read-only Operating System Minor Version Name operatingSystemMinorVersion Object ID 1.3.6.1.4.1.674.10899.2.3 Description Defines the minor version of the Operating System. Syntax DisplayString Access Read-only Change Management Group 691 Operating System Service Pack Major Version Name operatingSystemSPMajorVersion Object ID 1.3.6.1.4.1.674.10899.2.5 Description Defines the Operating System's Service Pack major version. Syntax DisplayString Access Read-only Operating System Service Pack Minor Version Name operatingSystemSPMinorVersion Object ID 1.3.6.1.4.1.674.10899.2.6 Description Defines the Operating System's Service Pack minor version. Syntax DisplayString Access Read-only Operating System Architecture Name operatingSystemArchitecture Object ID 1.3.6.1.4.1.674.10899.2.7 Description Defines the Operating System's architecture. Syntax DisplayString Access Read-only Inventory Collector Product Information The following objects describe the fields for the Inventory Collector. The Inventory Collector product variables are scalar objects, meaning that they are not related to other Inventory Collector base (MIB) objects and are thus not placed in a table. 692 Change Management Group Product ID Display Name Name productIDDisplayName Object ID 1.3.6.1.4.1.674.10899.100.1 Description Defines the display name of the product. Syntax DisplayString Access Read-only Product ID Description Name productIDDescription Object ID 1.3.6.1.4.1.674.10899.100.2 Description Provides a description of the product. Syntax DisplayString Access Read-only Product ID Vendor Name productIDVendor Object ID 1.3.6.1.4.1.674.10899.100.3 Description Provides name of the manufacturer of the product. Syntax DisplayString Access Read-only Product ID Version Name productIDVersion Object ID 1.3.6.1.4.1.674.10899.100.4 Description Describes the version of the product. Syntax DisplayString Access Read-only Change Management Group 693 Product ID Build Number Name productIDBuildNumber Object ID 1.3.6.1.4.1.674.10899.100.5 Description Describes the software build number of the product. Syntax DisplayString Access Read-only 694 Change Management Group 26 Dell Remote Access Controller Outof-Band Group The Dell Remote Access Controller Out-of-Band MIB contains information for both Chassis Management Controller (CMC) and RAC Legacy Alerting. This MIB consists of information for the following groups: Product Information The following MIB tables define the Dell RAC Out-of-Band group: DRsProductName Name DRsProductName Object ID 1.3.6.1.4.1.674.10892.2.1.1.1 Description Defines the product name of a chassis management controller. Syntax DellString Access Read-only DRsProductShortName Name DRsProductShortName Object ID 1.3.6.1.4.1.674.10892.2.1.1.2 Description Defines the short product name of a chassis management controller. Syntax DellString Access Read-only Dell Remote Access Controller Out-of-Band Group 695 DRsProductDescription Name DRsProductDescription Object ID 1.3.6.1.4.1.674.10892.2.1.1.3 Description Defines the product description of a chassis management controller. Syntax DellString Access Read-only DRsProductManufacturer Name DRsProductManufacturer Object ID 1.3.6.1.4.1.674.10892.2.1.1.4 Description Defines the product manufacturer of a chassis management controller. Syntax DellString Access Read-only DRsProductVersion Name DRsProductVersion Object ID 1.3.6.1.4.1.674.10892.2.1.1.5 Description Defines the product version of a chassis management controller. Syntax DellString Access Read-only DRsChassisServiceTag Name DRsChassisServiceTag Object ID 1.3.6.1.4.1.674.10892.2.1.1.6 Description Defines the Service Tag of the chassis. Syntax DellString Access Read-only 696 Dell Remote Access Controller Out-of-Band Group DRsProductURL Name DrsProductURL Object ID 1.3.6.1.4.1.674.10892.2.1.1.7 Description Defines the out-of-band UI URL of a chassis management controller. Syntax DellString Access Read-only DRsProductChassisAssetTag Name DRsProductChassisAssetTag Object ID 1.3.6.1.4.1.674.10892.2.1.1.8 Description Defines the Asset Tag of the chassis. Syntax DellString Access Read-only DRsProductChassisLocation Name DRsProductChassisLocation Object ID 1.3.6.1.4.1.674.10892.2.1.1.9 Description Defines the location of the chassis. Syntax DellString Access Read-only DRsProductChassisName Name DrsProductChassisName Object ID 1.3.6.1.4.1.674.10892.2.1.1.10 Description Defines the name of the chassis. Syntax DellString Access Read-only Dell Remote Access Controller Out-of-Band Group 697 DRsSystemServiceTag Name DRsSystemServiceTag Object ID 1.3.6.1.4.1.674.10892.2.1.1.11 Description Defines the service tag of a system. Syntax DellString Access Read-only DRsProductSystemAssetTag Name DRsProductSystemAssetTag Object ID 1.3.6.1.4.1.674.10892.2.1.1.12 Description Defines the asset tag of a system. Syntax DellString Access Read-only DRsProductSystemSlot Name DRsProductSystemSlot Object ID 1.3.6.1.4.1.674.10892.2.1.1.13 Description Defines the slot number of a CMC. Syntax DellString Access Read-only DRsProductType Name DRsProductType Object ID 1.3.6.1.4.1.674.10892.2.1.1.14 Description Defines type of a remote access card. Syntax DellRacType Access Read-only 698 Dell Remote Access Controller Out-of-Band Group DRsFirmwareVersion Name DRsFirmwareVersion Object ID 1.3.6.1.4.1.674.10892.2.1.2.1 Description Defines the firmware version of a chassis management controller. Syntax DellString Access Read-only Chassis Status The following MIB tables provide information on Chassis being monitored by the chassis management card. DRsGlobalSystemStatus Name DRsGlobalSystemStatus Object ID 1.3.6.1.4.1.674.10892.2.2.1 Description Defines the overall chassis status being monitored by the chassis management card. Syntax DellStatus Access Read-only DRsGlobalCurrStatus Name DRsGlobalCurrStatus Object ID 1.3.6.1.4.1.674.10892.2.3.1.1 Description Defines the overall chassis status being monitored by the chassis management card. Syntax DellStatus Access Read-only Dell Remote Access Controller Out-of-Band Group 699 DRsIOMCurrStatus Name DRsIOMCurrStatus Object ID 1.3.6.1.4.1.674.10892.2.3.1.2 Description Defines the IOM subsystem status being monitored by the chassis management card. Syntax DellStatus Access Read-only DRsKVMCurrStatus Name DRsKVMCurrStatus Object ID 1.3.6.1.4.1.674.10892.2.3.1.3 Description Defines the iKVM subsystem health status being monitored by the chassis management card. Syntax DellStatus Access Read-only DRsRedCurrStatus Name DRsRedCurrtatus Object ID 1.3.6.1.4.1.674.10892.2.3.1.4 Description Defines the redundancy status being monitored by the chassis management card. Syntax DellStatus Access Read-only 700 Dell Remote Access Controller Out-of-Band Group DRsPowerCurrStatus Name DRsPowerCurrStatus Object ID 1.3.6.1.4.1.674.10892.2.3.1.5 Description Defines the power subsystem health status being monitored by the chassis management card. Syntax DellStatus Access Read-only DRsFanCurrStatus Name DRsFanCurrStatus Object ID 1.3.6.1.4.1.674.10892.2.3.1.6 Description Defines the fan subsystem health status being monitored by the chassis management card. Syntax DellStatus Access Read-only DRsBladeCurrStatus Name DRsBladeCurrStatus Object ID 1.3.6.1.4.1.674.10892.2.3.1.7 Description Defines the blade subsystem health status being monitored by the chassis management card. Syntax DellStatus Access Read-only Dell Remote Access Controller Out-of-Band Group 701 DRsTempCurrStatus Name DRsTempCurrStatus Object ID 1.3.6.1.4.1.674.10892.2.3.1.8 Description Defines the temperature sensor subsystem health status being monitored by the chassis management card. Syntax DellStatus Access Read-only DRsCMCCurrStatus Name DRsCMCCurrStatus Object ID 1.3.6.1.4.1.674.10892.2.3.1.9 Description Defines the CMC health status being monitored by the chassis management card. Syntax DellStatus Access Read-only DRsChassisFrontPanelAmbientTemperature Name drsChassisFrontPanelAmbientTemperature Object ID 1.3.6.1.4.1.674.10892.2.3.1.10 Description Defines the ambient temperature reading (in degrees Celsius) for the chassis front panel controller. Syntax DellTemperatureReading Access Read-only 702 Dell Remote Access Controller Out-of-Band Group DRsCMAmbientTemperature Name drsCMCAmbientTemperature Object ID 1.3.6.1.4.1.674.10892.2.3.1.11 Description Defines the ambient temperature reading (in degrees Celsius) for the chassis management card. Syntax DellTemperatureReading Access Read-only DRsCMProcessorTemperature Name drsCMCProcessorTemperature Object ID 1.3.6.1.4.1.674.10892.2.3.1.12 Description Defines the temperature reading (in degrees Celsius) for the chassis management card. processor. Syntax DellTemperatureReading Access Read-only DRsGlobalPrevStatus Name DRsGlobalPrevStatus Object ID 1.3.6.1.4.1.674.10892.2.3.2.1 Description Defines the previous chassis status recorded by the chassis management card. Syntax DellStatus Access Read-only Dell Remote Access Controller Out-of-Band Group 703 DRsIOMPrevStatus Name DRsIOMPrevStatus Object ID 1.3.6.1.4.1.674.10892.2.3.2.2 Description Defines the previous IOM subsystem status recorded by the chassis management card. Syntax DellStatus Access Read-only DRsKVMPrevStatus Name DRsKVMPrevStatus Object ID 1.3.6.1.4.1.674.10892.2.3.2.3 Description Defines the previous iKVM subsystem health status recorded by the chassis management card. Syntax DellStatus Access Read-only DRsRedPrevStatus Name DRsRedPrevStatus Object ID 1.3.6.1.4.1.674.10892.2.3.2.4 Description Defines the previous redundancy status recorded by the chassis management card. Syntax DellStatus Access Read-only 704 Dell Remote Access Controller Out-of-Band Group DRsPowerPrevStatus Name DRsPowerPrevStatus Object ID 1.3.6.1.4.1.674.10892.2.3.2.5 Description Defines the previous power subsystem health status recorded by the chassis management card. Syntax DellStatus Access Read-only DRsFanPrevStatus Name DrsFanPrevStatus Object ID 1.3.6.1.4.1.674.10892.2.3.2.6 Description Defines the previous fan health status being monitored by the chassis management card. Syntax DellStatus Access Read-only DRsBladePrevStatus Name DRsBladePrevStatus Object ID 1.3.6.1.4.1.674.10892.2.3.2.7 Description Defines the previous blade subsystem health status recorded by the chassis management card. Syntax DellStatus Access Read-only Dell Remote Access Controller Out-of-Band Group 705 DRsTempPrevStatus Name DRsTempPrevStatus Object ID 1.3.6.1.4.1.674.10892.2.3.2.8 Description Defines the temperature sensor health status being monitored by the chassis management card. Syntax DellStatus Access Read-only DRsCMCPrevStatus Name DRsCMCPrevStatus Object ID 1.3.6.1.4.1.674.10892.2.3.2.9 Description Defines the CMC health status being monitored by the chassis management card. Syntax DellStatus Access Read-only DRsGlobalChangeTime Name DRsGlobalChangeTime Object ID 1.3.6.1.4.1.674.10892.2.3.3.1 Description Defines the timestamp of the most recent global status change. Syntax TimeTicks Access Read-only DRsIOMChangeTime Name DRsIOMChangeTime Object ID 1.3.6.1.4.1.674.10892.2.3.3.2 Description Defines the timestamp of the most recent IOM status change. Syntax TimeTicks Access Read-only 706 Dell Remote Access Controller Out-of-Band Group DRsKVMChangeTime Name DRsKVMChangeTime Object ID 1.3.6.1.4.1.674.10892.2.3.3.3 Description Defines the timestamp of the most recent iKVM status change. Syntax TimeTicks Access Read-only DRsRedChangeTime Name DRsRedChangeTime Object ID 1.3.6.1.4.1.674.10892.2.3.3.4 Description Defines the timestamp of the most recent Redundancy status change. Syntax TimeTicks Access Read-only DRsPowerChangeTime Name DRsPowerChangeTime Object ID 1.3.6.1.4.1.674.10892.2.3.3.5 Description Defines the timestamp of the most recent power health status change. Syntax TimeTicks Access Read-only DRsFanChangeTime Name DRsFanChangeTime Object ID 1.3.6.1.4.1.674.10892.2.3.3.6 Description Defines the timestamp of the most recent fan health status change. Syntax TimeTicks Access Read-only Dell Remote Access Controller Out-of-Band Group 707 DRsBladeChangeTime Name DRsBladeChangeTime Object ID 1.3.6.1.4.1.674.10892.2.3.3.7 Description Defines the timestamp of the most recent blade health status change. Syntax TimeTicks Access Read-only DRsTempChangeTime Name DRsTempChangeTime Object ID 1.3.6.1.4.1.674.10892.2.3.3.8 Description Defines the timestamp of the most recent temperature sensor health status change. Syntax TimeTicks Access Read-only DRsCMCChangeTime Name DRsCMCChangeTime Object ID 1.3.6.1.4.1.674.10892.2.3.3.9 Description Defines the timestamp of the most recent CMC health status change. Syntax TimeTicks Access Read-only 708 Dell Remote Access Controller Out-of-Band Group Chassis Power The following MIB tables provide information on the chassis management controller table entry. DRsCMC Power Table Name DRsCMCPowerTable Object ID 1.3.6.1.4.1.674.10892.2.4.1 Description Defines the CMC power table. Syntax SEQUENCE OF DrsCMCPowerTableEntry Access Not-accessible DRsCMC Power Table Entry Name DRsCMCPowerTableEntry Object ID 1.3.6.1.4.1.674.10892.2.4.1.1 Description Defines the CMC power table entry. Syntax DrsCMCPowerTableEntry Access Not-accessible DRsCMC PSUTable Name DrsCMCPSUTable Object ID 1.3.6.1.4.1.674.10892.2.4.2 Description Defines the CMC PSU table. Syntax SEQUENCE OF DrsCMCPSUTableEntry Access Not-accessible Dell Remote Access Controller Out-of-Band Group 709 DRsCMC PSUTableEntry Name DrsCMCPSUTableEntry Object ID 1.3.6.1.4.1.674.10892.2.4.2.1 Description Defines the CMC PSU table entry. Syntax DrsCMCPSUTableEntry Access Not-accessible CMC Power Information The following MIB tables provide information on the chassis power. DRsChassisIndex Name DrsChassisIndex Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.1 Description Defines the index (one-based) of the associated chassis. Syntax DellCMCPowerIndexRange Access Read-only DRsPotentialPower Name DRsPotentialPower Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.2 Description Defines the power (in Watts) required by the chassis infrastructure, plus the sum of the maximum power requirements for all systems currently turned on. Syntax DellPowerReading Access Read-only 710 Dell Remote Access Controller Out-of-Band Group DRsIdlePower Name DRsIdlePower Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.3 Description Defines the power (in Watts) required by the chassisinfrastructure, plus the sum of the minimum power requirements for all systems currently turned on. Syntax DellPowerReading Access Read-only DRsMaxPowerSpecification Name DRsMaxPowerSpecification Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.4 Description Defines the power limit (in Watts) at which server throttling takes place. Syntax DellPowerReading Access Read-only DRsPowerSurplus Name DRsPowerSurplus Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.5 Description Defines the power surplus (in Watts) remaining above the drsPotentialPower reading. Syntax DellPowerReading Access Read-only Dell Remote Access Controller Out-of-Band Group 711 DRsKWhCumulative Name DRsKWhCumulative Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.6 Description Defines the cumulative chassis power usage (in KWh) since last reset. Syntax DellPowerReading Access Read-only DRsKWhCumulativeTime Name DRsKWhCumulativeTime Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.7 Description Defines the timestamp of the most recent chassis power accumulator reset. Syntax DellTimestamp Access Read-only DRsWattsPeakUsage Name DRsWattsPeakUsage Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.8 Description Defines the chassis peak power usage (in Watts) since last reset. Syntax DellPowerReading Access Read-only DRsWattsPeakTime Name DRsWattsPeakTime Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.9 Description Defines the timestamp of the most recent chassis peak power usage. Syntax DellTimestamp Access Read-only 712 Dell Remote Access Controller Out-of-Band Group DRsWattsMinUsage Name DRsWattsMinUsage Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.10 Description Defines the chassis minimum power usage (in Watts) since last reset. Syntax DellPowerReading Access Read-only DRsWattsMinTime Name DRsWattsMinTime Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.11 Description Defines the timestamp of the most recent chassis minimum power usage. Syntax DellPowerReading Access Read-only DRsWattsResetTime Name DRsWattsResetTime Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.12 Description Defines the timestamp of the most recent reset of the chassis minimum/maximum Watts readings. Syntax DellTimestamp Access Read-only Dell Remote Access Controller Out-of-Band Group 713 DRsWattsReading Name DRsWattsReading Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.13 Description Defines the instantaneous chassis power usage (in Watts) Syntax DellPowerReading Access Read-only DRsAmpsReading Name DRsAmpsReading Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.14 Description Defines the instantaneous chassis current usage (in Watts). Syntax DellPowerReading Access Read-only CMC PSU Information The following MIB tables provide information on the chassis power supply unit. DRsPSUChassisIndex Name DRsPSUChassisIndex Object ID 1.3.6.1.4.1.674.10892.2.4.2.1.1 Description Defines the index (one-based) of the associated chassis. Syntax DellCMCPowerIndexRange Access Read-only 714 Dell Remote Access Controller Out-of-Band Group DRsPSUIndex Name DRsPSUIndex Object ID 1.3.6.1.4.1.674.10892.2.4.2.1.2 Description Defines the index (one-based) of the associated CMC PSU. Syntax DellCMCPSUIndexRange Access Read-only DRsPSULocation Name DRsPSULocation Object ID 1.3.6.1.4.1.674.10892.2.4.2.1.3 Description Defines the location of the CMC PSU. Syntax DellString Access Read-only DRsPSUMonitoringCapable Name DRsPSUMonitoringCapable Object ID 1.3.6.1.4.1.674.10892.2.4.2.1.4 Description Defines the PSU Monitoring capabilities, or the absence of a PSU in this location. Syntax DellCMCPSUCapable Access Read-only DRsPSUVoltsReading Name DRsPSUVoltsReading Object ID 1.3.6.1.4.1.674.10892.2.4.2.1.5 Description Defines the instantaneousPSU Voltage reading. Syntax DellPowerReading Access Read-only Dell Remote Access Controller Out-of-Band Group 715 DRsPSUAmpsReading Name DRsPSUAmpsReading Object ID 1.3.6.1.4.1.674.10892.2.4.2.1.6 Description Defines the instantaneous PSU Current reading. Syntax DellPowerReading Access Read-only DRsPSUWattsReading Name DrsPSUWattsReading Object ID 1.3.6.1.4.1.674.10892.2.4.2.1.7 Description Defines the instantaneous PSU Wattage reading. Syntax DellPowerReading Access Read-only Chassis Alerts The following MIB tables provide information on the chassis management controller alerts. DRsCASubSystem Name DrsCASubSystem Object ID 1.3.6.1.4.1.674.10892.2.20.10.1 Description Defines the Sub-System Name of the CMC Alert. Syntax DellString Access Read-only 716 Dell Remote Access Controller Out-of-Band Group DrsCASSCurrStatus Name DrsCASSCurrStatus Object ID 1.3.6.1.4.1.674.10892.2.20.10.2 Description Defines the Current Status of the Alerting Sub-System. Syntax DellStatus Access Read-only DrsCASSPrevStatus Name DrsCASSPrevStatus Object ID 1.3.6.1.4.1.674.10892.2.20.10.3 Description Defines the Previous Status of the Alerting Sub-System. Syntax DellStatus Access Read-only DrsCASSChangeTime Name DrsCASSChangeTime Object ID 1.3.6.1.4.1.674.10892.2.20.10.4 Description Defines the timestamp of Most Recent Change of the Alerting SubSystem. Syntax TimeTicks Access Read-only DrsCAMessage Name DrsCAMessage Object ID 1.3.6.1.4.1.674.10892.2.20.10.5 Description Defines the CSSD message of the CMC Alert. Syntax DellString Access Read-only Dell Remote Access Controller Out-of-Band Group 717 Legacy Alerting The following MIB tables provide information on the RAC legacy alerting. DRsAlertSystem Name DRsAlertSystem Object ID 1.3.6.1.4.1.674.10892.2.5000.10.1 Description Name of the system generating the alert. Syntax Octet String(SIZE (0..255)) Access Read-only DRsAlertTableIndexOID Name DRsAlertTableIndexOID Object ID 1.3.6.1.4.1.674.10892.2.5000.10.2 Description Alert Index Object Identifier. Syntax OBJECT IDENTIFIER Access Read Only DRsAlertMessage Name DRsAlertMessage Object ID 1.3.6.1.4.1.674.10892.2.5000.10.3 Description Message describing the alert. Syntax Octet String (SIZE (0..1024)) Access Read-only 718 Dell Remote Access Controller Out-of-Band Group DRsAlertCurrentStatus Name DRsAlertCurrentStatus Object ID 1.3.6.1.4.1.674.10892.2.5000.10.4 Description Current status of object causing the alert. Syntax DellStatus Access Read-only DRsAlertPreviousStatus Name DRsAlertPreviousStatus Object ID 1.3.6.1.4.1.674.10892.2.5000.10.5 Description Previous status of object causing the alert. Syntax DellStatus Access Read-only DRsAlertData Name DRsAlertData Object ID 1.3.6.1.4.1.674.10892.2.5000.10.6 Description Alert data Syntax Octet String (SIZE (0..1024)) Access Read-only Dell Remote Access Controller Out-of-Band Group 719 720 Dell Remote Access Controller Out-of-Band Group Traps 27 The Server Administrator generates events that result in Simple Network Management Protocol (SNMP) traps or operating system event logs. Remote Access Controller (RAC) and Baseboard Management Controller (BMC) can also generate SNMP traps in response to hardware events. This section describes the traps, also known as alerts, generated by the Server Administrator, RAC, and BMC. The Server Administrator generates events in response to changes in the status of sensors and other monitored parameters. When an event with predefined characteristics occurs on your system, the SNMP subagent sends information about the event, along with trap variables, to the management console. Each status change event generates a unique identifier called the TrapID and a trap description that describes the event. The TrapID and message uniquely describe the severity and cause of the event, and provide other relevant information such as the location of the event and the monitored item’s previous state. "Instrumentation Traps" on page 696 lists all Server Administrator Instrumentation TrapIDs in numerical order and includes each TrapID’s corresponding description, severity level, and cause. Description text in brackets (for example, ) describes the event-specific information provided by Server Administrator. "RAC Traps" on page 721 lists RAC TrapIDs in numerical order and includes each TrapID’s corresponding description, severity level, and cause. "BMC Traps" on page 726 lists BMC TrapIDs and includes each TrapID’s corresponding description and severity level. Trap Variables This section describes the variables that are sent to the management console to provide additional information about a trap or alert generated by some event on your system. The trap variables presented here apply to all Instrumentation and RAC traps. Trap variables are sent in the order listed and Traps 721 are reserved for use only in traps. When a varbind is created for a trap variable, a zero is appended to the object ID (OID) to create the OID for the varbind. System Variable Name alertSystem Object ID 1.3.6.1.4.1.674.10892.1.5000.10.1 Description Identifies the system generating the alert. Syntax DisplayString (SIZE (0..255)) Table Index OID Variable Name alertTableIndexOID Object ID 1.3.6.1.4.1.674.10892.1.5000.10.2 Description Specifies the object identifier for the index attribute in the table that contains the object causing the alert. Uniquely identifies the object causing the alert and can be used to correlate different alerts caused by the same object. Syntax OBJECT IDENTIFIER Message Variable Name alertMessage Object ID 1.3.6.1.4.1.674.10892.1.5000.10.3 Description Describes the alert. Syntax DisplayString (SIZE (0..1024)) Current Status Variable Name alertCurrentStatus Object ID 1.3.6.1.4.1.674.10892.1.5000.10.4 Description Specifies the current status of the object causing the alert. Syntax DellStatus 722 Traps Previous Status Variable Name alertPreviousStatus Object ID 1.3.6.1.4.1.674.10892.1.5000.10.5 Description Specifies the previous status of the object causing the alert. Syntax DellStatus Data Variable Name alertData Object ID 1.3.6.1.4.1.674.10892.1.5000.10.6 Description Provides Server Administrator-defined data related to the alert. Syntax Octet String (SIZE (0..1024)) Understanding the Trap Description Table 27-1 lists in alphabetical order each line item that may appear in the trap description. Description Line Item Explanation Action performed was: Specifies the automatic server recovery action that was performed, for example: Action performed was: Power cycle Action requested was: Specifies the user initiated host control action that was requested, for example: Action requested was: Reboot, shutdown OS first Traps 723 Description Line Item Explanation Additional details: Specifies possible additional details about the Additional details: Memory device: DIMM_1A Serial number: 11111111 Memory device: DIMM_1B Serial number: 22222222 Specifies any additional power supply information pertaining to the event, for example: Power supply input AC is off, Power supply POK (power OK) signal is not normal, Power supply is turned off Battery sensor status: Specifies the status reported by the battery sensor, for example: Battery sensor status: Predictive failure Chassis intrusion state: Specifies the chassis intrusion state (open or closed), for example: Chassis intrusion state: Open Chassis location: Specifies the name of the chassis that generated the message, for example: Chassis location: Main System Chassis Configuration error type: Specifies the type of configuration error that occurred, for example: Current sensor value (in Amps): Specifies the current sensor value in amps, for example: Configuration error type: Revision mismatch Current sensor value: 7.853 724 Traps Description Line Item Explanation Date and time of Specifies the date and time that an automatic action: server recovery action was performed, for example: Date and time of action: Fri May 30 23:55:44 2003. Description: Specifies the description of the event that occurred, for example: Description: Chipset Err: Critical Event sensor, front panel NMI / diagnostic interrupt was asserted. Device location: Specifies the location of the device in the specified chassis, for example: Device location: Mem Card A Discrete current state: Specifies the state of the current sensor, for example: Discrete current state: Good Discrete temperature state: Specifies the state of the temperature sensor, for example: Discrete temperature state: Good Discrete voltage state: Specifies the state of the voltage sensor, for example: Discrete voltage state: Good Fan sensor value: Specifies the fan speed in revolutions per minute (RPMs) or On/Off, for example: Fan sensor value (in RPM): 2600 Fan sensor value: Off Log type: Specifies the type of hardware log, for example: Log type: Embedded Server Management (ESM) Traps 725 Description Line Item Explanation Memory device bank location: Specifies the name of the memory bank in the system that generated the message, for example: Memory device bank location: Bank_1 Memory device location: Specifies the location of the memory module in the chassis, for example: Memory device location: DIMM_A Number of devices required for full redundancy: Specifies the number of power supply or cooling devices required to achieve full redundancy, for example: Number of devices required for full redundancy: 4 Peak value (in Watts): Specifies the peak value in Watts, for example: Possible memory module event cause: Specifies a list of possible causes for the memory module event, for example: Peak value (in Watts): 125 Possible memory module event cause: Single bit warning error rate exceeded Single bit error logging disabled Power Supply type:
Specifies the type of power supply, for example: Pre-failure state was: Specifies the status of the previous memory message, for example: Power Supply type: VRM Pre-failure state was: Failed Previous redundancy state was: Specifies the status of the previous redundancy message, for example: Previous redundancy state was: Lost Previous state was: Specifies the previous state of the sensor, for example: Previous state was: OK (Normal) 726 Traps Description Line Item Explanation Processor sensor status: Specifies the status of the processor sensor, for example: Processor sensor status: Configuration error Specifies the location of the redundant power Redundancy unit: Fan Enclosure Redundancy unit: SD card device type: Specifies the type of SD card device, for example: SD card device type: Hypervisor SD card state: Specifies the state of the SD card, for example: SD card state: Present, Failed Sensor location: Specifies the location of the sensor in the specified chassis, for example: Sensor location: CPU1 Temperature sensor value (in degrees Celsius): Specifies the temperature in degrees Celsius, for example: Temperature sensor value (in degrees Celsius): 30 Voltage sensor value (in Volts): Specifies the voltage sensor value in volts, for example: Voltage sensor value: 1.693 Understanding Trap Severity Traps often contain information about values recorded by probes or sensors. Probes and sensors monitor critical components for values such as amperage, voltage, and temperature. When an event occurs on your system, the Server Administrator sends information about one of the following event types to the system management console: • Information/Informational—An event that describes the successful operation of a unit, such as a power supply turning on or a sensor reading returning to normal. Traps 727 • Warning — An event that is not necessarily significant, but may indicate a possible future problem, such as crossing a warning threshold. • Critical/Error — A significant event that indicates actual or imminent loss of data or loss of function, such as crossing a failure threshold or a hardware failure. Instrumentation Traps This section describes the traps that are generated by the Instrumentation service of the Server Administrator. All of the traps documented in this section belong to the MIB enterprise identified by OID 1.3.6.1.4.1.674.10892.1 and are sent with all of the trap variables documented in the section, "Trap Variables" on page 690. The trap variables are sent in the order in which they are listed. The messages in the Description fields below show the format of the message that is sent in the alertMessage varbind. If a message in a Description field has multiple lines, the message contains newline (0Ah) characters that are part of the value in the alertMessage varbind. 728 Traps Miscellaneous Traps Table 27-2 lists Miscellaneous traps that inform you that certain alert systems are up and working. TrapID Description Severity Cause System Up 1001 Server Administrator startup complete Information Server Administrator completed its initialization. Thermal Shutdown 1004 Thermal shutdown protection has been initiated Error This message is generated when a system is configured for thermal shutdown due to an error event. If a temperature sensor reading exceeds the error threshold for which the system is configured, the operating system shuts down and the system powers off. This event may also be initiated on certain systems when a fan enclosure is removed from the system for an extended period of time. Automatic System Recovery 1006 Automatic System Error Recovery (ASR) action was performed Action performed was: Date and time of action: This message is generated when an automatic system recovery action is performed due to a hung operating system. The action performed and the date and time of the action are provided. Traps 729 TrapID Description Severity Cause Host System Reset 1007 User initiated host system Information User requested a host system control action control action to reboot, power off, or power cycle the system or Action requested was: another event such as thermal shutdown protection initiated a power off, operating system shutdown. System Peak Power New Peak 1013 System Peak Power detected new peak value Peak value (in Watts): Information This message is generated when the system peak power sensor has detected a new peak value. System Software Event 1014 System software event has Minor occured. Description: Date and time of action: 730 Traps This message is generated when a system software event occurs. The description of the event and the date and time of the event are provided. Temperature Probe Traps Temperature probes help protect critical components by alerting the systems management console when temperatures become too high inside a chassis. The temperature probe traps use additional variables: sensor location, chassis location, previous state, and temperature sensor value reported in degrees Celsius. TrapID Description Severity Cause Temperature Probe Normal 1052 Temperature sensor returned to a normal value Information A temperature sensor on the backplane board, system board, Sensor location: or drive carrier in the Chassis location: specified system returned to a valid Previous state was: range after crossing a If sensor type is not discrete: failure threshold. Temperature sensor value (in degrees The sensor location, Celsius): chassis location, If sensor type is discrete: Discrete previous state, and temperature state: temperature sensor value are provided. Temperature Probe Warning 1053 Temperature sensor detected a warning value Sensor location: Chassis location: Previous state was: If sensor type is not discrete: Temperature sensor value (in degrees Celsius): If sensor type is discrete: Discrete temperature state: Warning A temperature sensor on the backplane board, system board, or drive carrier in the specified system exceeded its warning threshold. The sensor location, chassis location, previous state, and temperature sensor value are provided. Traps 731 TrapID Description Severity Cause Error A temperature sensor on the backplane board, system board, or drive carrier in the specified system exceeded its failure threshold. The sensor location, chassis location, previous state, and temperature sensor value are provided. Error A temperature sensor on the backplane board, system board, or drive carrier in the specified system detected an error from which it cannot recover. The sensor location, chassis location, previous state, and temperature sensor value are provided. Temperature Probe Failure 1054 Temperature sensor detected a failure value Sensor location: Chassis location: Previous state was: If sensor type is not discrete: Temperature sensor value (in degrees Celsius): If sensor type is discrete: Discrete temperature state: Temperature Probe Non-recoverable 1055 Temperature sensor detected a non-recoverable value Sensor location: Chassis location: Previous state was: If sensor type is not discrete: Temperature sensor value (in degrees Celsius): If sensor type is discrete: Discrete temperature state: 732 Traps Cooling Device Traps Cooling device traps monitor how well a fan is functioning. TrapID Description Severity Cause Cooling Device Normal 1102 Fan sensor returned to a normal value Information A fan sensor reading on the specified system returned to a valid range Sensor location: threshold. The sensor Chassis location: location, chassis location, previous state, and fan Previous state was: sensor value are Fan sensor value: provided. Cooling Device Warning 1103 Fan sensor detected a warning value Warning Sensor location: Chassis location: Previous state was: Fan sensor value: A fan sensor reading in the specified system exceeded a warning threshold. The sensor location, chassis location, previous state, and fan sensor value are provided. Traps 733 TrapID Description Severity Cause Error A fan sensor in the specified system detected the failure of one or more fans. The sensor location, chassis location, previous state, and fan sensor value are provided. Error A fan sensor detected an error from which it cannot recover. The sensor location, chassis location, previous state, and fan sensor value are provided. Cooling Device Failure 1104 Fan sensor detected a failure value Sensor location: Chassis location: Previous state was: Fan sensor value: Cooling Device Non-recoverable 1105 Fan sensor detected a non-recoverable value Sensor location: Chassis location: Previous state was: Fan sensor value: 734 Traps Voltage Probe Traps Voltage probes monitor the number of volts across critical components. TrapID Description Severity Cause Voltage Probe Normal 1152 Voltage sensor returned to a normal value Information A voltage sensor in the specified system returned to a valid range Sensor location: after crossing a failure Chassis location: threshold. The sensor location, chassis If sensor type is not discrete: location, previous state, Voltage sensor value (in Volts): and voltage sensor value are provided. If sensor type is discrete: Discrete voltage state: Voltage Probe Warning 1153 Voltage sensor detected a warning value Warning Sensor location: Chassis location: If sensor type is not discrete: Voltage sensor value (in Volts): If sensor type is discrete: Discrete voltage state: A voltage sensor in the specified system exceeded its warning threshold. The sensor location, chassis location, previous state, and voltage sensor value are provided. Voltage Probe Failure 1154 Voltage sensor detected a failure value Sensor location: Chassis location: Previous state was: If sensor type is not discrete: Voltage sensor value (in Volts): Error A voltage sensor in the specified system exceeded its failure threshold. The sensor location, chassis location, previous state, and voltage sensor value are provided. If sensor type is discrete: Discrete voltage state: Traps 735 TrapID Description Severity Cause Error A voltage sensor in the specified system detected an error from which it cannot recover. The sensor location, chassis location, previous state, and voltage sensor value are provided. Voltage Probe Non-recoverable 1155 Voltage sensor detected a non-recoverable value Sensor location: Chassis location: Previous state was: If sensor type is not discrete: Voltage sensor value (in Volts): If sensor type is discrete: Discrete voltage state: 736 Traps Amperage Probe Traps Amperage probes measure the amount of current (in amperes) that is traversing critical components. TrapID Description Severity Cause Amperage Probe Normal 1202 Current sensor returned to a normal value Information A current sensor on the power supply for the specified system or returned to a valid Current sensor reading is withing range range after crossing a failure threshold. The Sensor location: sensor location, chassis Chassis location: location, previous state, Previous state was: and current sensor value are provided. If sensor type is not discrete: Current sensor value (in Amps): If sensor type is discrete: Discrete current state: Amperage Probe Warning 1203 Current sensor detected a warning value Sensor location: Chassis location: Previous state was: If sensor type is not discrete: Current sensor value (in Amps): If sensor type is discrete: Discrete current state: Warning A current sensor on the power supply for the specified system exceeded its warning threshold. The sensor location, chassis location, previous state, and current sensor value are provided. Traps 737 TrapID Description Severity Cause Amperage Probe Failure 1204 Current sensor detected a failure value Error Sensor location: Chassis location: Previous state was: If sensor type is not discrete: Current sensor value (in Amps): If sensor type is discrete: Discrete current state: A current sensor on the power supply for the specified system exceeded its failure threshold. The sensor location, chassis location, previous state, and current sensor value are provided. Amperage Probe Non-recoverable 1205 Current sensor detected a non-recoverable value Sensor location: Chassis location: Previous state was: If sensor type is not discrete: Current sensor value (in Amps): If sensor type is discrete: Discrete current state: 738 Traps Error A current sensor in the specified system detected an error from which it cannot recover. The sensor location, chassis location, previous state, and current sensor value are provided. Chassis Intrusion Traps Chassis intrusion traps are a security measure. Chassis intrusion means that someone is opening the cover to a system’s chassis. Alerts are sent to prevent unauthorized removal of parts from a chassis. TrapID Description Severity Cause Chassis Intrusion Normal 1252 Chassis intrusion returned to normal Information A chassis intrusion sensor in the specified system detected that a cover was Sensor location: was operating but has Chassis location: sensor location, chassis location, previous state, Previous state was: and chassis intrusion state Chassis intrusion state: Chassis Intrusion Detected 1254 Chassis intrusion detected Sensor location: Chassis location: Previous state was: Chassis intrusion state: Error A chassis intrusion sensor in the specified system detected that the system cover was opened while the system was operating. The sensor location, chassis location, previous state, and chassis intrusion state are provided. Traps 739 Redundancy Unit Traps Redundancy means that a system chassis has more than one of certain critical components. Fans and power supplies, for example, are so important for preventing damage or disruption of a computer system that a chassis may have extra fans or power supplies installed. Redundancy allows a second or nth fan to keep the chassis components at a safe temperature when the primary fan has failed. Redundancy is normal when the intended number of critical components are operating. Redundancy is degraded when a component fails but others are still operating. Redundancy is lost when the number of components functioning falls below the redundancy threshold. The number of devices required for full redundancy is provided as part of the trap message when applicable for the redundancy unit and the platform. For more details on redundancy computation, please refer to the respective platform documentation. TrapID Description Severity Cause Redundancy Normal 1304 740 Redundancy regained Information A redundancy sensor in the specified system detected Redundancy unit: device has been reconnected Chassis location: is in effect. The redundancy unit location, chassis Previous redundancy state was: location, and previous redundancy state are Number of devices required for provided. full redundancy: Traps TrapID Description Severity Cause Warning A redundancy sensor in the specified system detected that one of the components of the redundancy unit has failed but the unit is still redundant. The redundancy unit location, chassis location, and previous redundancy state are provided. Redundancy Degraded 1305 Redundancy degraded Redundancy unit: Chassis location: Previous redundancy state was: Number of devices required for full redundancy: Redundancy Lost 1306 Redundancy lost Warning or Redundancy unit: on the Chassis location: units that are Previous redundancy state was: functional) Number of devices required for full redundancy: A redundancy sensor in the specified system detected that one of the components in the redundant unit has been disconnected, has failed, or is not present. The redundancy unit location, chassis location, and previous redundancy state are provided. Traps 741 Power Supply Traps Power supply traps provide status and warning information for power supplies present in a particular chassis. TrapID Description Severity Cause Power Supply Normal 1352 Power supply returned to normal Information Sensor location: Chassis location: Previous state was: A power supply has been reconnected or replaced. The sensor location, chassis location, previous state, and additional information about the power supply event are provided. Power Supply type: If in configuration error state: Configuration error type: Power Supply Warning 1353 Power supply detected a warning Warning Sensor location: Chassis location: Previous state was: Power Supply type: If in configuration error state: Configuration error type: 742 Traps A power supply sensor has detected a warning condition. The sensor location, chassis location, previous state, and additional power supply status information are provided. TrapID Description Severity Cause Error A power supply has been disconnected or has failed. The sensor location, chassis location, previous state, and additional information about the power supply event are provided. Power Supply Failure 1354 Power supply detected a failure Sensor location: Chassis location: Previous state was: Power Supply type: If in configuration error state: Configuration error type: Memory Device Traps Memory device messages provide status and warning information for memory modules present in a particular system. Memory devices determine health status by counting the number of ECC memory corrections. NOTE: A value of failure or non-recoverable does not indicate a system failure or loss of data, but rather that the specified system exceeded the specified ECC correction threshold. Although the system continues to function, you should perform system maintenance as described in Table 27-10. TrapID Description 1403 Severity Memory device status: Warning Memory device location: Possible memory module event cause: Cause A memory device correction rate exceeded an acceptable value. The memory device status and location are provided. Traps 743 TrapID Description 1404 Severity Memory device status:
Error Memory device location: Possible memory module event cause: Cause A memory device correction rate exceeded an acceptable value, a memory spare bank was activated, or a Uncorrectable Memory Event occurred. The system continues to function normally (except for a Uncorrectable Memory Event). Clear the memory error on Uncorrectable Memory Event. Replace the memory module identified in the message during the system’s next scheduled maintenance. The memory device status and location are provided. Fan Enclosure Traps Some systems are equipped with a protective enclosure for fans. Fan enclosure traps monitor enclosures for whether foreign objects are present and for how long a fan enclosure is absent from a chassis. TrapID Description Severity Cause Information A fan enclosure has been inserted into the specified system. The sensor location and chassis location are provided. Fan Enclosure Insertion 1452 Fan enclosure inserted into system Sensor location:
Chassis location: 744 Traps TrapID Description Severity Cause Warning A fan enclosure has been removed from the specified system. The sensor location and chassis location are provided. Fan Enclosure Removal 1453 Fan enclosure removed from system Sensor location: Chassis location: Fan Enclosure Extended Removal 1454 Fan enclosure removed from Error system for an extended amount of time Sensor location: Chassis location: A fan enclosure has been removed from the specified system for a user-definable length of time. The sensor location and chassis location are provided. Traps 745 AC Power Cord Traps The AC power cord sensor monitors the presence of AC power for an AC power cord. AC power cord traps provide status and warning information for power cords that are part of an AC power switch, if your system supports AC switching. TrapID Description Severity Cause AC Power Cord No Power Non-redundant 1501 AC power cord is not being monitored Sensor location: Chassis location: Information The AC power cord status is not being monitored. This occurs when a system’s expected AC power configuration is set to nonredundant. The sensor location and chassis location information are provided. AC Power Cord Normal 1502 AC power has been restored Sensor location: Chassis location: Information An AC power cord that did not have AC power has had the power restored. The sensor location and chassis location information are provided. AC Power Cord Failure 1504 AC power has been lost Sensor location: Chassis location: 746 Traps Error An AC power cord has lost its power. The sensor location and chassis location information are provided. Hardware Log Traps Hardware logs provide hardware status messages to systems management software. On certain systems, the hardware log is implemented as a circular queue. When the log becomes full, the oldest status messages are overwritten when new status messages are logged. On some systems, the log is not circular. When the log becomes full, subsequent hardware status messages are lost. Hardware log sensor messages provide status and warning information about the noncircular logs that may fill up, resulting in lost status messages. TrapID Description Severity Cause Hardware Log Normal 1552 Log size is no longer near or at capacity Log type: Information The hardware log on the specified system is no longer near or at its capacity, usually as the result of clearing the log. The log type information is provided. Hardware Log Warning 1553 Log size is near or at capacity Warning The size of a hardware log on the specified system is near or at the capacity of the hardware log. The log type information is provided. Error The size of a hardware log on the specified system is at the capacity of the hardware log. The log type information is provided. Log type: Hardware Log Full 1554 Log size is full Log type: Processor Device Status Traps The BMC on some systems reports the status of processor devices. Processor device status traps provide status and warning information for processor devices present in a system with a BMC that reports the status of processor devices. Traps 747 TrapID Description Severity Cause Processor Device Status Normal 1602 Processor sensor returned to a normal value Sensor Location: Chassis Location: Information A processor sensor in the specified system transitioned back to a normal state. The sensor location, chassis location, previous state and processor sensor status are provided. Previous state was: Processor sensor status: Processor Device Status Warning 1603 Processor sensor detected a warning value Warning Sensor Location: Chassis Location: A processor sensor in the specified system is in a throttled state. The sensor location, chassis location, previous state and processor sensor status are provided. Previous state was: Processor sensor status: Processor Device Status Failure 1604 Processor sensor detected a failure Error value Sensor Location: Chassis Location: Previous state was: Processor sensor status: 748 Traps A processor sensor in the specified system is disabled, has a configuration error, or experienced a thermal trip. The sensor location, chassis location, previous state and processor sensor status are provided. Pluggable Device Traps Server Administrator monitors the addition and removal of pluggable devices such as memory cards. Device traps provide information about the addition and removal of such devices. TrapID Description Severity Cause Pluggable Device Addition 1651 Device added to system Device Location: Chassis Location: Information A device was added to the specified system. The device location, chassis location, and additional event details, if available, are provided. Pluggable Device Configuration Error 1653 Device configuration error detected Device Location: Chassis Location: Error A configuration error was detected for a pluggable device in the specified system. The device may have been added to the system incorrectly. The device location, chassis location, and additional event details, if available, are provided. Pluggable Device Removal 1652 Device removed from system Device Location: Chassis Location: Information A device was removed from the specified system. The device location, chassis location, and additional event details, if available, are provided Traps 749 Battery Traps Battery traps provide status and warning information for batteries present in a system with a BMC that reports the status of batteries. TrapID Description Severity Cause Battery Normal 1702 Battery sensor returned to a normal value Sensor Location: Chassis Location: Previous state was: Information A battery sensor in the specified system detected that a battery transitioned back to a normal state. The sensor location, chassis location, previous state, and battery sensor status are provided. Battery sensor status: Battery Warning 1703 Battery sensor detected a warning value or Battery is low Warning Sensor Location: Chassis Location: Previous state was: A battery sensor in the specified system detected that a battery is in a predictive failure state. The sensor location, chassis location, previous state, and battery sensor status are provided. Battery sensor status: Battery Failure 1704 Battery sensor detected a failure Critical value or Battery has failed or is absent Sensor Location: Chassis Location: Previous state was: Battery sensor status: 750 Traps A battery sensor in the specified system detected that a battery has failed or is absent. The sensor location, chassis location, previous state, and battery sensor status are provided. SD Card Device Traps On systems where the BMC reports the status of SD card devices, the SD card device traps provide status and error information. TrapID Description Severity Cause Critical An SD card device sensor in the specified system detected an error. The sensor location, chassis location, previous state and SD card device type are provided. The SD card state is provided if a SD card is present in the SD card device. SD Card Device Failure 1754 SD card device detected a failure Sensor Location: Chassis Location: Previous state was: SD card device type: SD card state: Traps 751 RAC Traps This section describes the traps that are generated by the SNMP agent of the Remote Access Controller (RAC). All of the enterprise-specific traps documented in this section belong to the MIB enterprise identified by OID 1.3.6.1.4.1.674.10892.2 and are sent with all of the trap variables documented in the section "Traps" on page 689. The trap variables are sent in the order in which they are listed. TrapID Name Description Severity 0 CodeStart SNMP agent is initializing itself 1 Authentic Request received Critical ation with an invalid Failure community name Category Cause Information Status TrapID Name Description 1001 The RAC Information Status generated a test trap event in response to a user request 752 alertDrscTest TrapEvent Traps Severity Error Supported by RAC Platform RAC power All on or reset. SNMP All request with an invalid community name. Category Cause Supporte d by RAC Platform A test SNMP All trap generated by a RAC. TrapID Name Description Severity Category Cause Supporte d by RAC Platform 1002 alertDrscAuth RAC Minor Error Authenticati on failures during a time period have exceeded a threshold 1003 alertDrscLost ESM 1004 alertDrscFound The RAC is Information Error ESM communicat ing normally with the baseboard management controller (ESM) RAC DRAC recovered III communicati on with ESM. 1005 alertDrscPower The RAC Critical Off has detected a system power state change to powered-off RAC DRAC III detected a system power state change to power-off. Critical The RAC cannot communicate with the baseboard management controller (ESM) Error RAC login All failure caused by authenticatio n failure, number of concurrent logins exceed limit, or permission denied. Error RAC lost Dell communicati Remote on with ESM. Access Controlle r (DRAC) III Error Traps 753 TrapID Name Description Severity Category Cause Supporte d by RAC Platform 1006 alertDrscPower The RAC Information Error On has detected a system power state change to powered-on RAC DRAC III detected a system power state change to power-on. 1007 alertDrsc Watchdog Expired The RAC Critical has detected that the system watchdog has expired indicating a system hang Event RAC has DRAC detected the III system watchdog expired (normally indicating a system hang). 1008 alertDrscBatt Low The RAC Minor Battery charge is below 25% indicating that the battery may only be able to power the DRSC for 810 minutes Error RAC detected its battery charge is below 25% full. 1009 Information Status alertDrscTemp The RAC Temperature Normal probe has returned to a normal value 1010 alertDrscTemp The RAC Temperature Warning probe has detected a Warning value 754 Traps Minor Status DRAC III RAC DRAC temperature III probe reading returned to normal. RAC DRAC temperature III probe reading exceeded warning threshold. TrapID Name Description Severity Category Cause 1011 alertDrscTemp The RAC Critical Temperature probe has detected a failure (or critical) value Critical Error RAC DRAC temperature III probe reading exceeded critical threshold. 1012 alertDrscVolt Normal The RAC Information Error voltage has returned to a normal value RAC voltage DRAC probe reading III returns to normal. 1013 alertDrscVolt Warning The RAC voltage probe has detected a warning value Minor Error RAC voltage DRAC probe reading III exceeded warning threshold. 1014 alertDrscVolt Critical The RAC voltage probe has detected a failure (or critical) value Critical Error RAC voltage DRAC probe reading III exceeded critical threshold. 1015 alertDrscSEL Warning The RAC Major has detected a new event in the System Event Log with Severity: Warning Error RAC All detected a new system event log with warning severity (detailed log info is in drsAlert Message varbind). Traps Supporte d by RAC Platform 755 TrapID Name Description Severity 1016 alertDrscSEL Critical The RAC Critical has detected a new event in the System Event Log with Severity: Critical 1017 Category Cause Supporte d by RAC Platform Error RAC All detected a new system event log with critical severity (detailed log info is in drsAlert Message varbind). alertDrscSEL The RAC Major 80 system event percentFull log is 80% full Status RAC All detected system event log is 80% full. 1018 alertDrscSEL The RAC Major 90 system event percentFull log is 90% full Status RAC All detected system event log is 90% full. 1019 alertDrscSEL The RAC Major 100 system event percentFull log is 100% full Status RAC All detected system event log is 100% full. 756 Traps TrapID Name Description 1020 The RAC Information Error has detected a new event in the System Event Log with Severity: Normal alertDrscSEL Normal Severity Category Cause Supporte d by RAC Platform RAC All detected a new system event log with normal severity (detailed log info is in drsAlert Message varbind). BMC Traps The BMC monitors the system for critical events by communicating with various sensors on the system board and by sending alerts and log events when certain parameters exceed their preset thresholds. All of the traps documented in this section belong to the MIB enterprise identified by OID 1.3.6.1.4.1.3183.1.1.1. TrapID Description Severity 262402 Generic Critical Fan Failure Critical 262530 Generic Critical Fan Failure Cleared Information 131330 Under-Voltage Problem (Lower Critical - going low) Critical 131458 Under-Voltage Problem Cleared Information 131841 Generic Critical Voltage Problem Critical 131840 Generic Critical Voltage Problem Cleared Information 65792 Under-Temperature Warning (Lower non-critical, going low) Warning 65920 Under-Temperature Warning Cleared Information 65794 Under-Temperature Problem (Lower Critical - going low) Critical 65922 Under-Temperature Problem Cleared Information Traps 757 TrapID Description Severity 65799 Over-Temperature warning (Upper non-critical, going high) Minor 65927 Over-Temperature warning Cleared Information 65801 Over-Temperature Problem (Upper Critical - going high) Critical 65929 Over-Temperature Problem Cleared Information 131328 Under-Voltage Warning (Lower Non Critical - going low) Warning 131456 Under-Voltage Warning Cleared Information 131330 Under-Voltage Problem (Lower Critical - going low) Critical 131458 Under-Voltage Problem Cleared Information 131335 Over-Voltage Warning (Upper Non Critical - going high) Warning 131463 Over-Voltage Warning Cleared Information 131337 Over-Voltage Problem (Upper Critical - going high) Critical 131465 Over-Voltage Problem Cleared Information 131841 Generic Critical Voltage Problem Critical 131840 Generic Critical Voltage Problem Cleared Information 356096 Chassis Intrusion - Physical Security Violation Critical 356224 Chassis Intrusion (Physical Security Violation) Event Cleared Information 262400 Generic Predictive Fan Failure (predictive failure asserted) Minor 262528 Generic Predictive Fan Failure Cleared Information 262402 Generic Critical Fan Failure Critical 262530 Generic Critical Fan Failure Cleared Information 264962 Fan redundancy has been degraded Warning 264961 Fan Redundancy Lost Critical 264960 Fan redundancy has returned to Normal Information 2715392 Battery Low (Predictive Failure) Warning 2715520 Battery Low (Predictive Failure) Cleared Information 2715393 Battery Failure Critical 2715521 Battery Failure Cleared Information 758 Traps TrapID Description Severity 487169 CPU Thermal Trip (Over Temperature Shutdown) Critical 487297 CPU Thermal Trip (Over Temperature Shutdown) Cleared Information 487168 CPU Internal Error Critical 487296 CPU Internal Error Cleared Information 487173 CPU Configuration Error Critical 487301 CPU Configuration Error Cleared Information 487175 CPU Presence (Processor Presence detected) Information 487303 CPU Not Present (Processor Not Present) Critical 487170 CPU BIST (Built In Self Test) Failure Critical 487298 CPU BIST (Built In Self Test) Failure Cleared Information 487176 CPU Disabled (Processor Disabled) Critical 487304 CPU Enabled (Processor Enabled) Information 487178 CPU Throttle (Processor Speed Reduced) Warning 487306 CPU Throttle Cleared (Normal Processor Speed) Information 527106 Power Supply Redundancy Degraded Warning 527105 Power Supply Redundancy Lost Critical 527104 Power Supply Redundancy has returned to Normal Information 552704 Power Supply Inserted Information 552832 Power Supply Removed Warning 552705 Power Supply Failure Critical 552833 Power Supply Failure Cleared Information 552706 Power Supply Warning Warning 552834 Power Supply Warning Cleared Information 552707 Power Supply AC Lost Critical 552835 Power Supply AC Restored Information 789249 Memory Redundancy has been Lost Critical 789248 Memory redundancy has returned to Normal Information 1076994 System Event Log (SEL) Cleared Information Traps 759 TrapID Description Severity 1076996 System Event Log (SEL) Full (Logging Disabled) Critical 2322176 ASR (Automatic System Recovery) Timer Expired Critical 2322177 ASR (Automatic System Recovery) Reset Occurred Critical 2322178 ASR (Automatic System Recovery) Power Down Occurred Critical 2322179 ASR (Automatic System Recovery) Power Cycle Occurred 760 Traps Critical Traps 761 762 Traps Storage Management Alert Reference 28 Storage Management’s alert or event management features let you monitor the health of storage resources such as controllers, connectors, array disks, and virtual disks. Alert Monitoring and Logging The Storage Management Service performs alert monitoring and logging. By default, the Storage Management Service starts when the managed system starts up. If you stop the Disk Management Service, then alert monitoring and logging stops. Alert monitoring does the following: • Updates the status of the storage object that generated the alert. • Propagates the storage object’s status to all the related higher objects in the storage hierarchy. For example, the status of a lower-level object are propagated up to the status displayed on the Health tab for the top-level storage object. • Logs an alert into the Alert log and Microsoft Windows application log. • Sends an Simple Network Management Protocol (SNMP) trap if the operating system’s SNMP service is installed and enabled. NOTE: Storage Management does not log alerts regarding the data I/O path. These alerts are logged by the respective RAID drivers in the system alert log. Storage Management Alert Reference 763 Viewing Alerts Storage Management generates alerts that are added to the Windows application alert log and to the Server Administrator Alert log. To view these alerts in Server Administrator: 1 Select the System object in the tree view. 2 Select the Logs tab. 3 Select the Alert subtab. You can also view these alerts in the Windows Event Viewer. Every alert consists of the following: • Severity — Shows the severity of alert. • Date and Time — Date and time when Storage Management logged the alert. • Description — A brief description of the alert. To expand or collapse the alert description, click the Description column heading. Alert Severity Levels Each alert message in the Storage Management alert log has a severity level which indicates the nature of the alert and is displayed in the Severity field of the alert message. The severity level indicates the nature of the alert. 764 Storage Management Alert Reference The alert severity levels are as follows: Table 28-1. Storage Management Alert Severity Alert Severity Component Status OK/Normal/Informational No action is required. The alert is provided for informational purposes and does not indicate an error condition. For example, the alert may indicate the normal start or stop of an operation. Warning/Non-critical A component requires attention. This alert indicates a potential problem, but does not necessarily mean that the system has currently lost data or is nonfunctional. For example, a Warning/Non-critical alert may indicate that a component (such as a temperature probe in an enclosure) has crossed a warning threshold. Critical/Failure/Error A component has either failed or failure is imminent. This alert indicates a serious problem such as data loss or a loss of function. For example, a Critical/Failure/Error alert may indicate that an array disk has failed. SNMP Support for Storage Management Alerts By default, Storage Management installs SNMP trap forwarding support. For this support to function, you should have SNMP installed on the managed system prior to installing Storage Management. NOTE: For more information on installation requirements and SNMP, see the Server Administrator documentation. SNMP Trap Forwarding The Storage Management alerts are displayed in the Server Administrator alert log and are forwarded to the Windows application alert log. If you have SNMP installed on the managed system (and the SNMP service is running), the Storage Management alerts in the Windows application alert log are forwarded as SNMP traps. In order for these traps to be viewable, however, a target system or application must be configured to receive these traps. SNMP traps that are generated by Storage Management can be viewed in any standard SNMP-compatible enterprise management console. Storage Management Alert Reference 765 The Windows SNMP service must be configured to forward the SNMP traps to the target system or application. When forwarding to an application, the application should also be configured to receive the SNMP traps. The IT Assistant application is already configured to receive the SNMP traps generated by Storage Management. See your Windows operating system documentation for information on configuring the operating system to forward SNMP traps. This information may be located under such topics as “setting up SNMP” or “SNMP traps.” When configuring SNMP for Windows, be sure that the SNMP traps are forwarded to the correct server. For information on configuring an application to receive SNMP traps, see the documentation for that application. SNMP Trap Definitions The Storage Management management information base (MIB) defines the SNMP traps that Storage Management generates. These traps correspond to the alerts documented in the "Alert Descriptions and Corrective Actions" on page 767 section. The MIB is located in ..\sm\mibs\dcstorag.mib, a subdirectory of the Storage Management installation directory. NOTE: Storage Management supports trap forwarding on both 32-bit and 64-bit operating systems. SNMP Trap Variables The Storage Management SNMP traps use a set of variables that are included with every trap. These variables are the following: 766 • messageIDEvent • descriptionEvent • locationEvent • objectNameEvent • objectOIDEvent • objectNexusEvent • currentStatusEvent • previousStatusEvent Storage Management Alert Reference Viewing SNMP Traps SNMP traps that are generated by Storage Management can be viewed in any standard SNMP-compatible enterprise management console. These traps are defined in the Storage Management MIB. These traps correspond to the alerts documented in the “Alert Descriptions and Corrective Actions” section. For more information on the MIB and its structure, as well as a change history of the SNMP traps, see the "Introduction" on page 17 section. For more information on configuring SNMP, see "SNMP Support for Storage Management Alerts" on page 765. Alert Descriptions and Corrective Actions The alerts generated by the redundant array of independent disks (RAID) or Small Computer System Interface (SCSI) controllers and supported by Storage Management are displayed in the Server Administrator Alert subtab or through Windows Event Viewer. These alerts can also be forwarded as SNMP traps to other applications. SNMP traps that are generated for the alerts are included in the Storage Management MIB. The SNMP traps for these alerts use all of the SNMP trap variables. For the list of storage management alerts and storage management messages, see the Dell OpenManage Server Administrator Messages Reference Guide available on the Dell Support website at support.dell.com/manuals. Storage Management Alert Reference 767 768 Storage Management Alert Reference 29 iDRAC7 MIB The Integrated Dell Remote Access Controller (iDRAC) MIB (filename iDRAC-MIB.txt) is the MIB supported by the Integrated Dell Remote Access Controller 7 (iDRAC7). This MIB provides management data that allows you to monitor devices and software on a system via an out-of-band connection to the iDRAC7 of a system. Supported Systems The iDRAC7 MIB is supported on the following systems: Blade Servers • PowerEdge M420 • PowerEdge M520 • PowerEdge M620 • PowerEdge M820 Rack and Tower Servers • PowerEdge R320 • PowerEdge R420 • PowerEdge R520 • PowerEdge R620 • PowerEdge R720 • PowerEdge R720XD • PowerEdge R820 • PowerEdge T320 • PowerEdge T420 • PowerEdge T620 iDRAC MIB iDRAC7 Supported SNMP Versions The following table identifies the SNMP version(s) that are supported by iDRAC7 for the given SNMP operations. SNMP Operations Supported SNMP version GET, GETNEXT, GETBULK SNMP v1 and v2c TRAP SNMP v1 iDRAC7 Out-of-Band Group The objects of the Integrated Dell Remote Access Controller (iDRAC) MIB (iDRAC-MIB.txt) are organized into subgroups of the iDRAC7 Out-of-Band Group. The subgroups are: • RAC Information Group • Chassis Information Group • System Information Group • Status Group The following sections document the subgroups and the objects within each subgroup. RAC Information Group The RAC Information Group objects provide information about the iDRAC. RAC Name Name racName Object ID 1.3.6.1.4.1.674.10892.5.1.1.1.0 Description This attribute defines the product name of a remote access card. Syntax StringType Access Read-only 770 iDRAC7 MIB RAC Short Name Name racShortName Object ID 1.3.6.1.4.1.674.10892.5.1.1.2.0 Description This attribute defines the short product name of a remote access card. Syntax StringType Access Read-only RAC Description Name racDescription Object ID 1.3.6.1.4.1.674.10892.5.1.1.3.0 Description This attribute defines the product description of a remote access card. Syntax StringType Access Read-only RAC Manufacturer Name racManufacturer Object ID 1.3.6.1.4.1.674.10892.5.1.1.4.0 Description This attribute defines the product manufacturer of a remote access card. Syntax StringType Access Read-only RAC Version Name racVersion Object ID 1.3.6.1.4.1.674.10892.5.1.1.5.0 Description This attribute defines the product version of a remote access card. Syntax StringType Access Read-only iDRAC7 MIB 771 RAC URL Name racURL Object ID 1.3.6.1.4.1.674.10892.5.1.1.6.0 Description This attribute defines the out-of-band UI URL of a remote access card. Syntax StringType Access Read-only RAC Type Name racType Object ID 1.3.6.1.4.1.674.10892.5.1.1.7.0 Description This attribute defines the type of a remote access card. Syntax RacTypeEnum Access Read-only RAC Firmware Version Name racFirmwareVersion Object ID 1.3.6.1.4.1.674.10892.5.1.1.8.0 Description This attribute defines the firmware version of a remote access card. Syntax StringType Access Read-only Chassis Information Group The Chassis Information Group objects provide information about the modular chassis in which a blade system resides. NOTE: This Chassis information is only available for modular/blade systems. For Rack and Tower systems, the information is empty. Currently there is just one object under the Chassis Information Group. 772 iDRAC7 MIB Chassis Service Tag Name chassisServiceTag Object ID 1.3.6.1.4.1.674.10892.5.1.2.1.0 Description This attribute defines the service tag of the enclosing chassis. Syntax StringType Access Read-only System Information Group The System Information Group objects provide information about the system in which the iDRAC resides. System Fully Qualified Domain Name Name systemFQDN Object ID 1.3.6.1.4.1.674.10892.5.1.3.1.0 Description This attribute defines the fully qualified domain name of the system. Syntax StringType Access Read-only System Service Tag Name systemServiceTag Object ID 1.3.6.1.4.1.674.10892.5.1.3.2.0 Description This attribute defines the service tag of the system. Syntax StringType Access Read-only System Express Service Code Name systemExpressServiceCode Object ID 1.3.6.1.4.1.674.10892.5.1.3.3.0 Description This attribute defines the express service code of the system. iDRAC7 MIB 773 Name systemExpressServiceCode Syntax StringType Access Read-only System Asset Tag Name systemAssetTag Object ID 1.3.6.1.4.1.674.10892.5.1.3.4.0 Description This attribute defines the asset tag of the system. Syntax StringType Access Read-only System Blade Slot Number Name systemBladeSlotNumber Object ID 1.3.6.1.4.1.674.10892.5.1.3.5.0 Description This attribute defines the slot number of the blade in the chassis. Syntax StringType Access Read-only System Operating System Name Name systemOSName Object ID 1.3.6.1.4.1.674.10892.5.1.3.6.0 Description This attribute defines the name of the operating system that the host is running. Syntax StringType Access Read-only System Form Factor Name systemFormFactor Object ID 1.3.6.1.4.1.674.10892.5.1.3.7.0 774 iDRAC7 MIB Name systemFormFactor Description This attribute defines the form factor of the system. Syntax SystemFormFactorEnum Access Read-only System Data Center Name Name systemDataCenterName Object ID 1.3.6.1.4.1.674.10892.5.1.3.8.0 Description This attribute defines the Data Center locator of the system. Syntax StringType Access Read-only System Aisle Name Name systemAisleName Object ID 1.3.6.1.4.1.674.10892.5.1.3.9.0 Description This attribute defines the Aisle locator of the system. Syntax StringType Access Read-only System Rack Name Name systemRackName Object ID 1.3.6.1.4.1.674.10892.5.1.3.10.0 Description This attribute defines the Rack locator of the system. Syntax StringType Access Read-only System Rack Slot Name systemRackSlot Object ID 1.3.6.1.4.1.674.10892.5.1.3.11.0 iDRAC7 MIB 775 Name systemRackSlot Description This attribute defines the Rack Slot locator of the system. Syntax StringType Access Read-only System Model Name Name systemModelName Object ID 1.3.6.1.4.1.674.10892.5.1.3.12.0 Description This attribute defines the model name of the system. Syntax StringType Access Read-only Status Group The Status Group objects provide status information about the system and storage. Global System Status Name globalSystemStatus Object ID 1.3.6.1.4.1.674.10892.5.2.1.0 Description This attribute defines the overall rollup status of all components in the system being monitored by the remote access card. Syntax ObjectStatusEnum Access Read-only System LCD Status Name systemLCDStatus Object ID 1.3.6.1.4.1.674.10892.5.2.2.0 Description This attribute defines the system status as it is reflected by the LCD front panel. Not all system components may be included. Syntax ObjectStatusEnum 776 iDRAC7 MIB Name systemLCDStatus Access Read-only Global Storage Status Name globalStorageStatus Object ID 1.3.6.1.4.1.674.10892.5.2.3.0 Description This attribute defines the overall storage status being monitored by the remote access card. Syntax ObjectStatusEnum Access Read-only iDRAC7 Traps The iDRAC7 generates events that result in Simple Network Management Protocol (SNMP) traps and/or entries in the iDRAC7 Lifecycle Log. This section describes the traps, also known as alerts, generated by the iDRAC7. The iDRAC7 generates events in response to changes in the status of sensors and other monitored parameters. When an event with predefined characteristics occurs on your system, the SNMP subagent sends information about the event, along with trap variables, to the management console. Each event generates an identifier called the trap ID and a list of trap variables that provide additional details about the event. The trap variables are listed in the following "Trap Variables" on page 778. The traps of the iDRAC7 MIB are organized into five subgroups of traps. Each subgroup corresponds to one of the five categories of events that iDRAC7 supports (the System Health, Storage Health, Updates, Audit, and Configuration categories). Here is a list of the trap subgroups are: • System Trap Group • Storage Trap Group • Updates Trap Group • Audit Trap Group • Configuration Trap Group iDRAC7 MIB 777 The trap subgroups, and all the traps within each trap subgroup, are described and listed in sections following the "Trap Variables" section. NOTE: The traps listed in this document can be correlated to specific events that are documented in the Dell Event Message Reference guide. There is 1-to-many relationship between SNMP traps and events in iDRAC7. To correlate a trap to a specific event or set of events, you can match the Trap ID value of a trap in this document to the Trap/Event ID value of events in the Dell Event Message Reference guide. Trap Variables This section lists the six variables that are sent with iDRAC7 traps to provide additional information about a trap or alert generated by some event on the system. The trap variables presented here apply to all iDRAC7 traps. The trap variables are sent in the order listed and are reserved for use only in traps. Alert Message ID Variable Name alertMessageID Object ID 1.3.6.1.4.1.674.10892.5.3.1.1.0 Description Message ID of the event. Syntax DisplayString (SIZE (0..8)) Alert Message Variable Name alertMessage Object ID 1.3.6.1.4.1.674.10892.5.3.1.2.0 Description Message describing the alert. Syntax StringType Alert Current Status Variable Name alertCurrentStatus Object ID 1.3.6.1.4.1.674.10892.5.3.1.3.0 Description Current status of object causing the alert, if applicable. Syntax ObjectStatusEnum 778 iDRAC7 MIB Alert System Service Tag Variable Name alertSystemServiceTag Object ID 1.3.6.1.4.1.674.10892.5.3.1.4.0 Description Service tag of the system. Syntax DisplayString (SIZE (0..16)) Alert System FQDN Variable Name alertSystemFQDN Object ID 1.3.6.1.4.1.674.10892.5.3.1.5.0 Description Fully qualified domain name of the system. Syntax StringType Alert FQDD Variable Name alertFQDD Object ID 1.3.6.1.4.1.674.10892.5.3.1.5.0 Description Fully qualified device descriptor of the device. Syntax DisplayString (SIZE (0..512)) System Trap Group The System Trap Group contains traps that fall under the “System Health” event category of the iDRAC7. System Health traps are traps those are generally generated in response to events related to the hardware of the system in which an iDRAC7 resides.Amperage Probe Traps iDRAC7 MIB 779 Table 29-1. Amperage Probe Traps TrapID Description Category SubCategory Severity Amperage Informational Amperage Minor Amperage Critical SubCategory Severity System Health Auto Sys Reset Critical Category SubCategory Severity System Health Battery Event Informational System Health Battery Event Minor System Health Battery Event Critical Amperage Probe Normal 2179 Current sensor reading is System within range. Health Amperage Probe Warning 2178 Current sensor has System detected a warning value. Health Amperage Probe Failure 2177 Current sensor has detected a failure value. System Health Table 29-2. Automatic System Recovery Trap TrapID Description Category Automatic System Recovery 2233 Automatic system recovery (ASR) was performed. Table 29-3. Battery Traps TrapID Description Battery Normal 2227 Battery state has returned to normal; or battery presence had been detected. Battery Warning 2226 Battery is low. Battery Failure 2225 780 Battery has failed or battery is absent. iDRAC7 MIB Table 29-4. Processor Device Status Traps TrapID Description Category SubCategory Severity System Health Processor Informational System Health Processor Minor System Health Processor Critical SubCategory Severity Proc Absent Critical Processor DeviceStatus Normal 2243 Processor device status has returned to normal. ProcessorDeviceStatusWarning 2242 Processor device status has detected a warning. ProcessorDeviceStatusFailure 2241 Processor device status has detected a failure. Table 29-5. Processor Device Absent Trap TrapID Description Category Processor Device Absent 2457 Processor device is absent. System Health iDRAC7 MIB 781 Table 29-6. Fan Traps TrapID Description Category SubCategory Severity System Health Fan Event Informational System Health Fan Event Minor System Health Fan Event Critical SubCategory Severity System Health Hardware Config Informational System Health Hardware Config Minor System Health Hardware Config Critical SubCategory Severity System Health Memory Informational Memory device status is System noncritical. Health Memory Minor Fan Information 2155 Fan information. Fan Warning 2154 Fan warning. Fan Failure 2153 Fan failure. Table 29-7. Hardware Configuration Traps TrapID Description Category Hardware Configuration Information 2331 Hardware configuration information. Hardware Configuration Warning 2330 Hardware configuration warning. Hardware Configuration Failure 2329 Hardware configuration failure or critical event. Table 29-8. Memory Device Traps TrapID Description Category Memory Device Information 2267 Memory device informational event. Memory Device Warning 2266 Memory Device Failure 782 iDRAC7 MIB TrapID Description 2265 Category Memory device status is System critical. Health SubCategory Severity Memory Critical iDRAC7 MIB 783 Table 29-9. NIC Traps TrapID Description Category SubCategory Severity System Health NIC Config Informational System Health NIC Config Minor System Health NIC Config Critical Table 29-10. Operation System ("OS") Event Traps TrapID Description Category SubCategory Severity Network Information 2091 Network information. Network Warning 2090 Network warning. Network Failure 2089 Network failure or critical event. OS Information 2411 An OS graceful stop occurred; or an OS graceful shut-down occurred. System Health OS Event Informational System Health OS Event Critical Category SubCategory Severity System Health PCI Device Informational OS Failure 2409 A critical stop occurred during OS load; or a runtime critical stop occurred. Table 29-11. PCI Device Traps TrapID Description PCI Device Information 2419 An informational event was detected for a PCI device. PCI Device Warning 784 iDRAC7 MIB TrapID Description Category SubCategory Severity 2418 System Health PCI Device Minor An error was detected for System a PCI device. Health PCI Device Critical A warning event was detected for a PCI device. PCI Device Failure 2417 iDRAC7 MIB 785 Table 29-12. Physical Disk Traps TrapID Description Category SubCategory Severity Physical Disk Information 2299 Physical disk information. System Health Physical Disk Informational System Health Physical Disk Minor System Health Physical Disk Critical Category SubCategory Severity BIOS POST Critical SubCategory Severity Physical Disk Warning 2298 Physical disk warning. Physical Disk Failure 2297 Physical disk failure. Table 29-13. BIOS POST Trap TrapID Description Bios Post Failure 2425 System BIOS detected a System failure. Health Table 29-14. Power Supply Traps TrapID Description Category Power Supply Normal 2187 Power supply has returned to normal. System Health Power Supply Informational System Health Power Supply Minor System Health Power Supply Critical Power Supply Warning 2186 Power supply has detected a warning. Power Supply Failure 2185 786 Power supply has detected a failure. iDRAC7 MIB Table 29-15. Power Supply Absent Trap TrapID Description Category SubCategory Severity PSU Absent Critical SubCategory Severity System Health Power Usage Informational System Health Power Usage Minor The system halted System because system power Health exceeds capacity; or the system performance degraded because power draw exceeds the power threshold. Power Usage Critical SubCategory Severity System Health Redundancy Informational Redundancy is degraded. System Health Redundancy Minor Redundancy Critical Power Supply Absent 2465 Power supply is absent. System Health Table 29-16. Power Usage Traps TrapID Description Category Power Usage Information 2275 System performance restored. Power Usage Warning 2274 System performance degraded. Power Usage Failure 2273 Table 29-17. Redundancy Traps TrapID Description Category Redundancy Information 2475 Redundancy information. Redundancy Degraded 2474 Redundancy Lost 2473 Redundancy is lost. System Health iDRAC7 MIB 787 Table 29-18. Integrated Dual SD Module Traps TrapID Description Category SubCategory Severity Integrated Dual SD ModuleInformation 2211 Integrated Dual SD Module information. System Health IDSDM Media Informational System Health IDSDM Media Minor System Health IDSDM Media Critical Integrated Dual SD ModuleWarning 2210 Integrated Dual SD Module warning. Integrated Dual SD ModuleFailure 2297 Integrated Dual SD Module failure. Table 29-19. Integrated Dual SD Module Absent Trap TrapID Description Category SubCategory Severity Integrated Dual SD ModuleAbsent 2481 Integrated Dual SD Module is absent. System Health IDSDM Absent Table 29-20. Integrated Dual SD Module Redundancy Traps TrapID Description Category SubCategory Critical Severity Integrated Dual SD Module Redundancy Information 2491 Integrated Dual SD Module redundancy information. System Health IDSDM Redundancy Informational Integrated Dual SD Module Redundancy Degraded 2490 Integrated Dual SD Module redundancy is degraded. System Health IDSDM Redundancy Minor IDSDM Redundancy Critical Integrated Dual SD Module Redundancy Lost 2489 788 Integrated Dual SD Module redundancy is lost. iDRAC7 MIB System Health Table 29-21. Security Event Traps TrapID Description Category SubCategory Severity System Health Security Event Informational Security failure or critical System event. Health Security Event Critical SubCategory Severity System Health Sys Event Log Informational System Health Sys Event Log Minor System Event Log failure System or critical event. Health Sys Event Log Critical SubCategory Severity Security Information 2387 Security information. Security Failure 2385 Table 29-22. System Event Log Traps TrapID Description Category System Event Log Information 2379 System Event Log information. System Event Log Warning 2378 System Event Log warning. System Event Log Failure 2377 Table 29-23. Temperature Probe Traps TrapID Description Category Temperature Probe Normal 2163 Temperature sensor value is within range. System Health Temperature Informational Temperature Probe Warning 2162 Temperature sensor has System detected a warning value. Health Temperature Minor Temperature Probe Failure 2161 Temperature sensor has detected a failure value. System Health Temperature Critical iDRAC7 MIB 789 Table 29-24. Temperature Statistics Traps TrapID Description Category SubCategory Severity Temperature Statistics Warning 2522 Temperature has been System above the warning or Health critical threshold level for a long enough period of time to be considered in a warning state. Temperature Minor Statistics Temperature Statistics Failure 2521 Temperature has been System above the warning or Health critical threshold level for a long enough period of time to be considered in a critical state. Table 29-25. vFlash Media Device Traps TrapID Description Category Temperature Critical Statistics SubCategory Severity vFlash Media Device Information 2507 vFlash Media device information. System Health vFlash Event Informational System Health vFlash Event Minor System Health vFlash Event Critical vFlash Media Device Warning 2506 vFlash Media device warning. vFlash Media Device Failure 2505 vFlash Media device failure. Table 29-26. vFlash Media Device Absent Trap TrapID Description Category SubCategory Severity vFlash Media Device Absent 2515 790 vFlash Media device is absent. iDRAC7 MIB System Health vFlash Absent Informational Table 29-27. Voltage Probe Traps TrapID Description Category SubCategory Severity Voltage Informational Voltage Minor Voltage Critical Voltage Probe Normal 2171 Voltage sensor reading is System within range. Health Voltage Probe Warning 2170 Voltage sensor has System detected a warning value. Health Voltage Probe Failure 2169 Voltage sensor has detected a failure value. System Health Storage Trap Group The Storage Trap Group contains traps that fall under the Storage event category of iDRAC7. Storage traps are traps generated in response to events related to the external storage subsystem of the system in which iDRAC7 resides. iDRAC7 MIB 791 Table 29-28. Battery Traps TrapID Description Category SubCategory Severity Storage Battery Event Informational Storage Battery Event Minor Storage Battery Event Critical Category SubCategory Severity Storage Storage Contr Informational Storage Storage Contr Minor Storage Storage Contr Critical Category SubCategory Severity Storage Storage Enclosr Informational Storage Storage Enclosr Minor Battery Normal 4275 Battery state has returned to normal; or battery presence has been detected. Battery Warning 4274 Battery is low. Battery Failure 4273 Battery has failed or battery is absent. Table 29-29. Controller Traps TrapID Description Storage Controller Information 4331 Controller information. Storage Controller Warning 4330 Controller warning. Storage Controller Failure 4329 Controller failure. Table 29-30. Enclosure Traps TrapID Description Storage Enclosure Information 4339 Enclosure information. Storage Enclosure Warning 4338 792 Enclosure warning. iDRAC7 MIB TrapID Description Category SubCategory Severity Storage Storage Enclosr Critical Storage Enclosure Failure 4337 Enclosure failure. iDRAC7 MIB 793 Table 29-31. Fan Traps TrapID Description Category SubCategory Severity Storage Fan Event Informational Storage Fan Event Minor Storage Fan Event Critical SubCategory Severity Storage Fan Information 4203 Fan information. Storage Fan Warning 4202 Fan warning. Storage Fan Failure 4201 Fan failure. Table 29-32. Physical Disk Traps TrapID Description Category Storage Physical Disk Information 4347 Physical disk information. Storage Physical Disk Informational Storage Physical Disk Minor Storage Physical Disk Critical Storage Physical Disk Warning 4346 Physical disk warning. Storage Physical Disk Failure 4345 Physical disk failure. Table 29-33. Power Supply Traps TrapID Description Category SubCategory Severity Storage Power Supply Information 4235 Power supply information. Storage Power Supply Informational Storage Power Supply Minor Storage Power Supply Critical Storage Power Supply Warning 4234 Power supply warning. Storage Power Supply Failure 4233 794 Power supply failure. iDRAC7 MIB Table 29-34. Storage Management Status Traps TrapID Description Category SubCategory Severity Storage Management Information 4179 Storage Management Storage information. There is no global status change associated with this trap. Storage Informational Storage Minor Storage Critical SubCategory Severity Storage Management Warning 4178 Storage Management has Storage detected a device independent warning condition. There is no global status change associated with this trap. Storage Management Failure 4177 Storage Management has Storage detected a device independent error condition. There is no global status change associated with this trap. Table 29-35. Temperature Probe Traps TrapID Description Category Storage Temperature Probe Information 4211 Temperature probe information. Storage Temperature Informational Storage Temperature Probe Warning 4210 Temperature probe warning. Storage Temperature Minor Storage Temperature Critical Storage Temperature Probe Failure 4209 Temperature probe failure. iDRAC7 MIB 795 Table 29-36. Virtual Disk Trap TrapID Description Category SubCategory Severity Virtual Disk Informational Storage Virtual Disk Minor Storage Virtual Disk Critical Storage VirtualDisk Information 4355 Virtual disk information. Storage Storage Virtual Disk Warning 4354 Virtual disk warning. Storage Virtual Disk Failure 4353 Virtual disk failure. Updates Trap Group The Updates Trap Group contains traps that fall under the Updates event category of iDRAC7. Updates traps are traps generated in response to events related to firmware/driver upgrades/downgrades. NOTE: Currently there are no Update traps. Audit Trap Group The Audit Trap Group contains traps that fall under the Audit event category of iDRAC7. Audit traps are traps generated in response to audit-type events of iDRAC7, such as authorizing of debugging, changes to iDRAC7 license state, power state changes, etc. 796 iDRAC7 MIB Table 29-37. Debug Traps TrapID Description Category SubCategory Severity Audit Debug Informational Audit Debug Minor SubCategory Severity Audit DRAC IP Address Informational Category SubCategory Severity Audit Licensing Informational Audit Licensing Minor Audit Licensing Critical Debug Information 8595 Debug authorized. DebugWarning 8594 Debug authorization failed. Table 29-38. iDRAC IP Address Change Trap TrapID Description Category iDRAC IP Address Change 8499 iDRAC IP address has changed. Table 29-39. License Traps TrapID Description License Information 8515 License information. License Warning 8514 License warning. License Failure 8513 License failure. Table 29-40. System Power State Change Trap TrapID Description Category SubCategory Severity System Power State Change Information 8579 Host is going through a power state change (powering on or powering off). Audit System Info Informational Configuration Trap Group The Configuration Trap Group contains traps that fall under the iDRAC7 MIB 797 Configuration event category of the iDRAC7. Configuration traps are traps generated in response to events related to hardware configuration changes and software configuration changes. Table 29-41. Test Trap TrapID Description Category SubCategory Severity Test Trap Event 10395 The iDRAC generated a Configuratio Test Alert test trap event in n response to a user request. 798 iDRAC7 MIB Informational iDRAC7 MIB 799 800 iDRAC7 MIB 30 Standard Data Type Definitions This appendix contains definitions for data types that are standard in most contexts across the information technology industry. These are the most common data types for describing variable values defined in the 10892.mib, dcs3rmt.mib and dcs3fru.mib files. Server Administrator-specific variable values are defined in the last section of the section in which they are introduced. Common Data Types Common data types include several types of strings, the object range, signed and unsigned bit ranges, and the familiar Boolean (true or false) data type. Table 30-1. Common Data Types Variable Name: Definition DellString DisplayString (SIZE (0..64)) DellSecurityString DisplayString (SIZE (0..255)) DellCostofOwnershipString DisplayString (SIZE (0..64)) DellObjectRange INTEGER (1..128) DellUnsigned8BitRange INTEGER (1..256) DellUnsigned16BitRange INTEGER (1..65535) DellUnsigned32BitRange INTEGER (1..2147483647) DellSigned32BitRange INTEGER (-2147483647..2147483647) DellBoolean INTEGER (0..1 (FALSE = 0, TRUE = 1)) Standard Data Type Definitions 801 Variables with Data Types of State Capabilities and State Capabilities Unique Variables with definitions of StateCapabilities or StateCapabilitiesUnique are integers representing a series of bit definitions. They are NOT enumerations and should be treated as bit fields. The value is passed as a decimal value. The decimal value should be converted to hex and the appropriate bits should be parsed from hex. Some of the more common bit combinations are defined in some variables, but not all combinations are or will be defined. Table 30-2. Dell State Capabilities Variable Name: DellStateCapabilities Data Type: Integer Possible Data Values Meaning of Data Value if set to zero(0) The object has no capabilities. unknownCapabilities(1) The object’s capabilities are unknown. enableCapable(2) The object can be disabled (offline, a binary 0 value) or enabled (online, a binary 1 value). notReadyCapable(4) The object is not ready. enableAndNotReadyCapable Enable and not ready capable. (6) 802 Standard Data Type Definitions Table 30-3. Dell State Settings Variable Name: DellStateSettings Data Type: Integer Possible Data Values Meaning of Data Value if set to zero(0) The object has no settings capabilities and its state is disabled. unknown(1) The object’s state is unknown. enabled(2) The object’s state is disabled (offline, a binary 0 value) or enabled (online, a binary 1 value). notReady(4) The object is not ready. enableAndNotReady(6) The object is enabled and not ready. Table 30-4. Dell Probe Capabilities Variable Name: DellProbeCapabilities Data Type: Integer Possible Data Values Meaning of Data Value if set to zero(0) The object has no capabilities. upperNonCriticalThresholdSet The upper noncritical threshold can be set. Capable(1) lowerNonCriticalThresholdSet The lower noncritical threshold can be set. Capable(2) upperNonCriticalThresholdDef The upper noncritical threshold can be set to default. aultCapable(4) lowerNonCriticalThresholdDef The lower noncritical threshold can be set to default. aultCapable(8) Standard Data Type Definitions 803 Dell Status Data Types Status data types include DellStatus, DellStatusRedundancy, and DellStatusProbe. Table 30-5. Dell Status Variable Name: DellStatus Data Type: Integer Possible Data Values Meaning of Data Value other(1) The object’s status is not one of the following: unknown(2) The object’s status is unknown. ok(3) The object’s status is OK. nonCritical(4) The object’s status is warning, noncritical. critical(5) The object’s status is critical (failure). nonRecoverable(6) The object’s status is nonrecoverable (dead). Table 30-6. Dell Status Redundancy Variable Name: DellStatusRedundancy Data Type: Integer Possible Data Values Meaning of Data Value other(1) The object’s status is not one of the following: unknown(2) The object’s redundancy status is unknown. full(3) The object is fully redundant. degraded(4) The object’s redundancy has been degraded. lost(5) The object’s redundancy has been lost. notRedundant(6) Redundancy does not apply or it is not redundant. 804 Standard Data Type Definitions Table 30-7. Dell Status Probe Variable Name: DellStatusProbe Data Type: Integer Possible Data Values Meaning of Data Value other(1) The object’s status is not one of the following: unknown(2) The status of the object is unknown. ok(3) The status of the object is OK. nonCriticalUpper(4) The object is at the noncritical upper limit. CriticalUpper(5) The object is at the critical upper limit. nonRecoverableUpper(6) The object is at the nonrecoverable upper limit. nonCriticalLower(7) The object is at the noncritical lower limit. criticalLower(8) The object is at the critical lower limit. nonRecoverableLower(9) The object is at the nonrecoverable lower limit. failed(10) The status of the object is failed. Dell Date Variable Name: DellDate Data Type: DellUnsigned64BitRange Octet String (SIZE(8)) The DellDate definition is required because SNMP V1 does not support 64-bit ranges. The information sent back by this subagent has the most significant byte of the information as the first byte. For example, the hex address 0x1029384754657687 is sent as hex: 0001 0000 0010 1001 0011 1000 0100 0111 ... Byte 1 Byte 2 Byte 3 Byte 4. Standard Data Type Definitions 805 Full Dates Variable Name: DellDateName Data Type: DisplayString DisplayString (SIZE (25)) Full dates are defined in the ASCII format: yyyyMMddhhmmss.uuuuuu+fff or yyyyMMddhhmmss.uuuuuu-fff where yyyy is the year, MM is the month, dd is the day, hh are the hours, mm are the minutes, and ss are the seconds. uuuuuu is the number of microseconds, and +fff or -fff is the offset from UTC in minutes. For example, Friday, October 31, 2001, at 6:05:19 PM CST would be represented as 20011031180519.000000-360. The values are zero-padded, and if a valid value for a field is not deliverable, each character in the field is replaced with an asterisk (*) character. 806 Standard Data Type Definitions 31 SNMP Sample Output This appendix contains the sample output from the Simple Network Management Protocol (SNMP) covering the first four groups of the Instrumentation management information base (MIB) sample output from the Simple Network Management Protocol (SNMP) covers the first four groups of the Instrumentation management information base (MIB). Values are shown for each object identifier (OID) in the Instrumentation MIB Version Group, the Systems Management Software Group, the System State Group, the Chassis Information Table, and Event Log Table. The data is from a Dell PowerEdge 2650 system. Walk .1.3.6.1.4.1.674.10892 Community: 'public') (Agent: 'SERVER01', .iso.org.dod.internet.private.enterprises.dell.server3 1.3.6.1.4.1.674.10892.1.1.1.0 = 5 1.3.6.1.4.1.674.10892.1.1.2.0 = 3 1.3.6.1.4.1.674.10892.1.1.3.0 = 0 1.3.6.1.4.1.674.10892.1.100.1.0 Administrator' = 'Server 1.3.6.1.4.1.674.10892.1.100.2.0 = '5.3.0' 1.3.6.1.4.1.674.10892.1.100.3.0 = 4522 1.3.6.1.4.1.674.10892.1.100.4.0 software for Dell systems.' = 'Management 1.3.6.1.4.1.674.10892.1.100.5.0 = 1 1.3.6.1.4.1.674.10892.1.100.6.0 = 1 1.3.6.1.4.1.674.10892.1.100.7.0 = 'No Updates' SNMP Sample Output 807 1.3.6.1.4.1.674.10892.1.100.8.0 'https://1.2.3.4:1311' = 1.3.6.1.4.1.674.10892.1.100.9.0 = 'en_US' 1.3.6.1.4.1.674.10892.1.100.10.0 = '2.2.0' 1.3.6.1.4.1.674.10892.1.100.11.0 = 0 1.3.6.1.4.1.674.10892.1.100.12.0 = 1 1.3.6.1.4.1.674.10892.1.100.13.0 = 'Dell Inc.' 1.3.6.1.4.1.674.10892.1.200.10.1.1.1 = 1 1.3.6.1.4.1.674.10892.1.200.10.1.2.1 = 3 1.3.6.1.4.1.674.10892.1.200.10.1.3.1 = 2 1.3.6.1.4.1.674.10892.1.200.10.1.4.1 = 3 1.3.6.1.4.1.674.10892.1.200.10.1.5.1 = '\02' 1.3.6.1.4.1.674.10892.1.200.10.1.6.1 = 3 1.3.6.1.4.1.674.10892.1.200.10.1.7.1 = '\03' 1.3.6.1.4.1.674.10892.1.200.10.1.8.1 = '\02\02' 1.3.6.1.4.1.674.10892.1.200.10.1.9.1 = 3 1.3.6.1.4.1.674.10892.1.200.10.1.10.1 = '\03\03' 1.3.6.1.4.1.674.10892.1.200.10.1.11.1 = '\02\02\02\02\02\02\02\02\02\02\02\02\02\02\02\02\02\ 02\02\02' 1.3.6.1.4.1.674.10892.1.200.10.1.12.1 = 3 1.3.6.1.4.1.674.10892.1.200.10.1.13.1 = '\03\03\03\03\03\03\03\03\03\03\03\03\03\03\03\03\03\ 03\03\03' 1.3.6.1.4.1.674.10892.1.200.10.1.20.1 '\02\02\02\02\02' = 1.3.6.1.4.1.674.10892.1.200.10.1.21.1 = 808 SNMP Sample Output 3 1.3.6.1.4.1.674.10892.1.200.10.1.22.1 '\03\03\03\03\03' = 1.3.6.1.4.1.674.10892.1.200.10.1.23.1 '\02\02\02\02\02\02' = 1.3.6.1.4.1.674.10892.1.200.10.1.24.1 = 1.3.6.1.4.1.674.10892.1.200.10.1.25.1 '\03\03\03\03\03\03' = 1.3.6.1.4.1.674.10892.1.200.10.1.26.1 '\02\02\02\02' = 1.3.6.1.4.1.674.10892.1.200.10.1.27.1 = 1.3.6.1.4.1.674.10892.1.200.10.1.28.1 '\03\03\03\03' = 1.3.6.1.4.1.674.10892.1.200.10.1.29.1 = '\02' 1.3.6.1.4.1.674.10892.1.200.10.1.30.1 = 3 1.3.6.1.4.1.674.10892.1.200.10.1.31.1 = '\03' 1.3.6.1.4.1.674.10892.1.200.10.1.41.1 = 3 1.3.6.1.4.1.674.10892.1.200.10.1.42.1 = 3 1.3.6.1.4.1.674.10892.1.200.10.1.43.1 = '\03' 3 3 1.3.6.1.4.1.674.10892.1.300.10.1.1.1 = 1 1.3.6.1.4.1.674.10892.1.300.10.1.2.1 = 0 1.3.6.1.4.1.674.10892.1.300.10.1.3.1 = 2 1.3.6.1.4.1.674.10892.1.300.10.1.4.1 = 3 1.3.6.1.4.1.674.10892.1.300.10.1.5.1 = 0 1.3.6.1.4.1.674.10892.1.300.10.1.6.1 = 23 1.3.6.1.4.1.674.10892.1.300.10.1.7.1 Chassis' = 'Main System 1.3.6.1.4.1.674.10892.1.300.10.1.8.1 = 'Dell Inc.' SNMP Sample Output 809 1.3.6.1.4.1.674.10892.1.300.10.1.9.1 2650' = 'PowerEdge 1.3.6.1.4.1.674.10892.1.300.10.1.10.1 = 'ASSETTAG' 1.3.6.1.4.1.674.10892.1.300.10.1.11.1 = '1234567' 1.3.6.1.4.1.674.10892.1.300.10.1.12.1 = 254 1.3.6.1.4.1.674.10892.1.300.10.1.13.1 = 289 1.3.6.1.4.1.674.10892.1.300.10.1.14.1 = 4 1.3.6.1.4.1.674.10892.1.300.10.1.15.1 = 'SERVER01' 1.3.6.1.4.1.674.10892.1.300.10.1.16.1 '20050513095213.000000-360' = 1.3.6.1.4.1.674.10892.1.300.10.1.17.1 '20050513100052.000000-360' = 1.3.6.1.4.1.674.10892.1.300.10.1.18.1 the value' = 'Please set 1.3.6.1.4.1.674.10892.1.300.10.1.19.1 the value' = 'Please set 1.3.6.1.4.1.674.10892.1.300.10.1.20.1 the value' = 'Please set 1.3.6.1.4.1.674.10892.1.300.10.1.21.1 = 3 1.3.6.1.4.1.674.10892.1.300.10.1.22.1 = 0 1.3.6.1.4.1.674.10892.1.300.10.1.23.1 = 0 1.3.6.1.4.1.674.10892.1.300.10.1.24.1 = 0 1.3.6.1.4.1.674.10892.1.300.10.1.25.1 = 0 1.3.6.1.4.1.674.10892.1.300.10.1.26.1 = 0 1.3.6.1.4.1.674.10892.1.300.10.1.27.1 = 0 1.3.6.1.4.1.674.10892.1.300.10.1.28.1 = 8 1.3.6.1.4.1.674.10892.1.300.10.1.29.1 = 2 1.3.6.1.4.1.674.10892.1.300.10.1.30.1 = 1 810 SNMP Sample Output 1.3.6.1.4.1.674.10892.1.300.10.1.31.1 = 15 1.3.6.1.4.1.674.10892.1.300.10.1.32.1 = 0 1.3.6.1.4.1.674.10892.1.300.10.1.33.1 = 27 1.3.6.1.4.1.674.10892.1.300.10.1.34.1 = 0 1.3.6.1.4.1.674.10892.1.300.10.1.35.1 = 1 1.3.6.1.4.1.674.10892.1.300.10.1.36.1 = 480 1.3.6.1.4.1.674.10892.1.300.10.1.37.1 = 1 1.3.6.1.4.1.674.10892.1.300.10.1.38.1 = 2 1.3.6.1.4.1.674.10892.1.300.10.1.39.1 = 2 1.3.6.1.4.1.674.10892.1.300.10.1.44.1 = 0 1.3.6.1.4.1.674.10892.1.300.10.1.45.1 = 0 1.3.6.1.4.1.674.10892.1.300.40.1.1.1.1 = 1 1.3.6.1.4.1.674.10892.1.300.40.1.2.1.1 = 1 1.3.6.1.4.1.674.10892.1.300.40.1.3.1.1 = 8 1.3.6.1.4.1.674.10892.1.300.40.1.4.1.1 = 2 1.3.6.1.4.1.674.10892.1.300.40.1.5.1.1 cleared' = 'Log 1.3.6.1.4.1.674.10892.1.300.40.1.6.1.1 = 2 1.3.6.1.4.1.674.10892.1.300.40.1.7.1.1 = 3 1.3.6.1.4.1.674.10892.1.300.40.1.8.1.1 '20050513100047.000000-360' = SNMP Sample Output 811 812 SNMP Sample Output Index Numerics 1403, 743 BIOS Setup Control Group, 391 variable values, 420 1404, 744 1602, 748 C 1603, 748 Change, 685 1604, 748 Change Management Group, 685 1651, 749 1653, 749 Cluster Group, 529 Cluster Table, 529 variable values, 532 A Cost of Ownership Group COO Cost Event Log Table, 452 COO Lease Information Table, 456 COO Maintenance Table, 462 COO Options Table, 460 COO Repair Table, 464 COO Schedule Number Table, 459 COO Service Contract Table, 450 COO Support Information Table, 466 COO Trouble Ticket Table, 468 COO Warranty Table, 454 Cost of Ownership Table, 439 Cost of Ownership tables, 439 Application, 688 Application Group, 688 B BIOS Group BIOS Setup Control Table, 391 Diskette Control Table, 412 IDE Control Table, 410 Network Interface Control Table, 414 Parallel Port Control Table, 404 SCSI Control Table, 402 Serial Port Control Table, 406 USB Control Table, 408 BIOS Group tables, 391 Index 813 D E data types common, 801 state capabilities, 802 state settings, 803 status, 804 status probe, 805 status redundancy, 804 Event Log viewing entries, 764 Dell RAC Out-of-Band Group, 695 Chassis Alerts, 716 Chassis Power, 709 Chassis Status, 699 CMC Power Information, 710 CMC PSU Information, 714 Legacy Alerting, 718 Product Information, 695 Device added to system, 749 Device configuration error detected, 749 Device Group, 686 Cache Device Table, 279 Generic Device Table, 296 Keyboard Device Table, 266 Memory Device Mapped Address Table, 293 Memory Device Table, 285 PCI Device Configuration Space Table, 302 PCI Device Table, 299 Pointing Device Table, 264 Processor Device Table, 269 variable values, 322 814 Index G Global Data Group, 558 I Introduction Server Administrator Change Management MIB, 23 Server Administrator Instrumentation MIB, 18 Server Administrator Remote Access MIB, 21 Server Administrator Storage Management MIB, 22 Inventory, 685 Inventory Group, 685 L Local Response Agent Group LRA Action Table, 434 LRA Global Settings, 431 LRA Global Settings Table, 432 variable values, 436 Local Response Agent Group tables, 431 Logical Devices Group, 669 M Memory Device Port Table, 238 Monitor Port Table, 241 Parallel Port Table, 246 Pointing Port Table, 229 Processor Port Table, 235 Serial Port Table, 250 Small Computer System Interface Port Table, 244 variable values, 257 Memory device correction rate crossed a warning threshold, 743 Memory device ECC Correctable error count crossed a warning threshold, 743 Memory Group Physical Memory Tables, 365 variable values, 374, 381 Memory Group Variable Values, 385 MIB minor version number, 42 MIB Major Version Number, 41 O Operating System Group, 691 Memory Table, 125 Operating System Table, 123 Operating System Memory Table, 125 P Physical Devices Group, 564 Physical Memory Card Table, 382 Pluggable Device Traps, 749 Port Group Keyboard Port Table, 232 Power Group AC Power Cord Table, 173 AC Power Switch Table, 171 Amperage Probe Table, 165 Battery Table, 176 Power Supply Table, 156 Power Unit Table, 153 Power Usage Table, 178 variable values, 187 Voltage Probe Table, 160 Power Group tables, 153 Processor Device Status Traps, 747 Processor sensor detected a failure value, 748 Processor sensor detected a warning value, 748 Processor sensor returned to a normal state, 748 R Redundant Memory Unit Table, 379 Index 815 Remote Access Group Remote Access Table, 480 Remote SNMP Trap Table, 497 Remote User Administration Table, 489 Remote User Dial-In Configuration Table, 506 Remote User Dial-Out Table, 509 Remote Flash BIOS Group variable values, 226 S sample SNMP output, 807 Slot Group System Slot Table, 351 variable values, 355 SNMP introduction to, 33 SNMP MIB OIDs, 35 SNMP security, 36 SNMP traps, 37 SNMP basic terminology fields, 27-28 managed object, 26 MIB, 26 SNMP, 25 variable, 26 SNMP support, configuring, 765 SNMP tables, 29 example, 29 reference guide content, 31, 36 SNMP traps, 767 816 Index Storage Management Event Group, 683 Storage Management Information Group, 557 System Resource Group Direct Memory Access Table, 145 Input/Output Port Table, 136 Interrupt Table, 142 Map Table, 131 Memory Table, 139 Owner Table, 133 variable values, 148 System State Table, 49, 51, 351 systems management software, 43 build number systems, 44 description name, 44 name, 44-46 preferred protocol, 45 supported protocol, 45 version number name, 44 T Thermal Group Cooling Device Table, 203 Cooling Unit Table, 201 Temperature Probe Table, 209 variable values, 215 trap variables, 721 current status, 722 data, 723 message, 722 previous status, 723 system, 722 table index OID, 722 traps, 728 AC power cord traps, 746 amperage probe traps, 737 chassis intrusion traps, 739 cooling device traps, 733 fan enclosure traps, 744 hardware log traps, 747 memory device traps, 743 miscellaneous traps, 729 power supply traps, 742 redundancy unit traps, 740 temperature probe traps, 731 understanding the trap descriptions, 723 understanding trap severity, 727 voltage probe traps, 735 U User Security Table, 219, 223 V variable names capability, 28 settings, 28 state, 28 status, 28 Viewing SNMP traps, 767 Index 817 818 Index
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Format : application/pdf Creator : Dell Inc. Title : Dell OpenManage Server Administrator Version 7.1 SNMP Reference Guide Subject : Reference Guide4 Description : Reference Guide4 Producer : Acrobat Distiller 10.0.1 (Windows); modified using iTextSharp 5.1.3 (c) 1T3XT BVBA Keywords : esuprt_electronics#esuprt_software#Dell OpenManage Server Administrator Version 7.1#dell-opnmang-srvr-admin-v7.1#Reference Guide4 Create Date : 2012:06:26 11:57:39Z Creator Tool : FrameMaker 7.1 Modify Date : 2013:12:24 12:39:34-06:00 Page Mode : UseOutlines Page Count : 818 Author : Dell Inc. Productcode : dell-opnmang-srvr-admin-v7.1 Typecode : rg4 Typedescription : Reference Guide4 Languagecodes : en-us Sectioncode : Sectiondescription : Publishdate : 2012-06-26 00:00:00 Expirydate : 9999-09-09 00:00:00 Manualurl : http://ftp.dell.com/manuals/all-products/esuprt_electronics/esuprt_software/esuprt_ent_sys_mgmt/dell-opnmang-srvr-admin-v7.1_Reference Guide4_en-us.pdf Readytocopy : false Futureproductindication : No Categorypathforfutureproducts : Businesskeywords : Filesize : 2084 Creationdate : D:20120626115739Z Moddate : D:20121119092712-06'00'EXIF Metadata provided by EXIF.tools