Dell Openmanage Server Administrator Version 7 1 Snmp Reference Guide 7.1

2015-01-05

: Dell Dell-Dell-Openmanage-Server-Administrator-Version-7-1-Snmp-Reference-Guide-137796 dell-dell-openmanage-server-administrator-version-7-1-snmp-reference-guide-137796 dell pdf

Open the PDF directly: View PDF PDF.
Page Count: 818

DownloadDell Dell-Dell-Openmanage-Server-Administrator-Version-7-1-Snmp-Reference-Guide- OpenManage Server Administrator Version 7.1 SNMP Reference Guide  Dell-dell-openmanage-server-administrator-version-7-1-snmp-reference-guide
Open PDF In BrowserView PDF
Dell OpenManage
Server Administrator

SNMP Reference Guide

Notes and Cautions
NOTE: A NOTE indicates important information that helps you make better use of
your computer.
A CAUTION indicates potential damage to hardware or loss of data if instructions
are not followed.

__________________
Information in this publication is subject to change without notice.
© 2003–2012 Dell Inc. All rights reserved.
Reproduction of these materials whatsoever without the written permission of Dell Inc. is strictly
forbidden.
Trademarks used in this text: Dell™, the DELL™ logo, PowerEdge™, PowerVault™, and
OpenManage™ are trademarks of Dell Inc. Microsoft® and Windows® are either trademarks or
registered trademarks of Microsoft Corporation in the United States and/or other countries. Intel®,
Itanium®, Pentium®, Atom®, and Celeron® are registered trademarks, and MMX™, Xeon™, and
Core™ are trademarks of Intel Corporation in the United States and/or other countries. VESA® is a
registered trademark of the Video Electronics Standards Association. AMD™, AMD Athlon™, AMD
Opteron™, AMD Sempron™, AMD Turion™, AMD Phenom™, and AMD Duron™ are trademarks
of Advanced Micro Devices, Inc. VIA C7™ and VIA Eden™ are either trademarks or registered
trademarks of VIA Technology, Inc. Crusoe™ and Efficeon™ are trademarks of Transmeta
Corporation in the USA and other countries.
Other trademarks and trade names may be used in this document to refer to either the entities claiming
the marks and names or their products. Dell Inc. disclaims any proprietary interest in trademarks and
trade names other than its own.
2012 - 6

Contents
1

Introduction .

. . . . . . . . . . . . . . . . . . . . . .

Supported SNMP Versions

. . . . . . . . . . . . . . .

Introduction to the SNMP Reference Guide

. . . . . .

17
17
18

Server Administrator Instrumentation MIB

. . . .

18

Server Administrator Remote Access MIB

. . . .

21

Server Administrator Baseboard Management Controller, ASF
MIB . . . . . . . . . . . . . . . . . . . . . . . . . 21
Server Administrator Field Replaceable Unit MIB .

22

Server Administrator Storage Management MIB

.

22

Server Administrator Change Management MIB

.

23

Dell Remote Access Controller Out-of-Band MIB

.

24

. . . . .

24

. . . . . . . . . . . . .

25

How This Guide Defines Technical Terms
SNMP Basic Terminology

. . . .

28

. . . . . . . . . . . . . . . . . . . . . . .

29

Frequently Used Terms in Variable Names
Tables

Section Organization

. . . . . . . . . . . . . . . .

Other Documents You May Need

. . . . . . . . .

32
33

Introduction to the Server Administrator SNMP Subagent 33
SNMP Management Information Base Object Identifiers 35
SNMP Security .

. . . . . . . . . . . . . . . . . .

Management Actions
SNMP Traps

2

36

. . . . . . . . . . . . . . .

37

. . . . . . . . . . . . . . . . . . . .

37

Dell OpenManage Server Administrator Version
7.1 39
What’s New in This Release

. . . . . . . . . . . . . .

Contents

39

3

Storage Management Group MIB
iDRAC7 MIB

3

. . . . . . . . .

39

. . . . . . . . . . . . . . . . . . . .

40

Instrumentation MIB Version Group

. . . .

41

Management Information Base Major Version Number

41

Management Information Base Minor Version Number

42

Management Information Base Maintenance Version Number 42

4

Systems Management Software Group .
Systems Management Software

.

43

. . . . . . . . . . . .

43

Systems Management Software Variable Values

5

6

. . .

47

System State Group .

. . . . . . . . . . . . . . . .

49

System State Group Table

. . . . . . . . . . . . . . . .

49

System State Table

. . . . . . . . . . . . . . . . .

49

System State Table

. . . . . . . . . . . . . . . . .

51

Chassis Information Group

. . . . . . . . . . .

71

Chassis Information Group Tables

. . . . . . . . . . .

71

. . . . . . . . . . . . .

71

. . . . . . . . . . . . . . . . . . . . .

84

Chassis Information Table
UUID Table

POST Log Table .
Event Log Table

. . . . . . . . . . . . . . . . . .

86

. . . . . . . . . . . . . . . . . . .

88

System BIOS Table

. . . . . . . . . . . . . . . . .

Firmware Table

. . . . . . . . . . . . . . . . . . .

98

Intrusion Table

. . . . . . . . . . . . . . . . . . .

101

Baseboard Table

. . . . . . . . . . . . . . . . . .

Chassis Information Group Variable Values

4

Contents

91

. . . . . .

103
108

7

Operating System Group

. . . . . . . . . . . .

Operating System Memory Table

8

System Resource Group

125

. . . . . . . . .

. . . . . . . . . . . .

System Resource Group Tables

123

131
131

. . . . . . . . . . . . .

System Resource Map Table .

. . . . . . . . . . .

131

. . . . . . . . . .

133

System Resource Owner Table

System Resource Input/Output (I/O) Port Table

. .

136

System Resource Memory Table .

. . . . . . . . .

139

System Resource Interrupt Table

. . . . . . . . .

142

System Resource Direct Memory Access (DMA) Table 145
System Resource Group Variable Values

9

Power Group

148

. . . . . . . .

. . . . . . . . . . . . . . . . . . . . .

153

Power Group Tables .

. . . . . . . . . . . . . . . . . .

153

Power Unit Table

. . . . . . . . . . . . . . . . . .

153

Power Supply Table

. . . . . . . . . . . . . . . .

156

Voltage Probe Table

. . . . . . . . . . . . . . . .

160

Amperage Probe Table .

. . . . . . . . . . . . . .

165

AC Power Switch Table

. . . . . . . . . . . . . .

171

. . . . . . . . . . . . . . .

173

. . . . . . . . . . . . . . . . . . . .

176

AC Power Cord Table
Battery Table

Power Usage Table

. . . . . . . . . . . . . . . .

178

Power Profile Table

. . . . . . . . . . . . . . . .

184

Power Group Variable Values .

10 Thermal Group

. . . . . . . . . . . . . . . . . . .

Thermal Group Tables

187

. . . . . . . . . . . . .

201

. . . . . . . . . . . . . . . . . .

Cooling Unit Table

. . . . . . . . . . . . . . . . .

Cooling Device Table .

. . . . . . . . . . . . . . .

Contents

201
201
204

5

Temperature Probe Table
Thermal Group Variable Values

11 User Security Group

. . . . . . . . . . . . .

209

. . . . . . . . . . . . .

215

. . . . . . . . . . . . . . .

User Security Group Table
User Security Table .

. . . . . . . . . . . . . . .

219

. . . . . . . . . . . . . . . .

219

12 Remote Flash BIOS Group
Remote Flash BIOS Group Table
Remote Flash BIOS Table .

. . . . . . . . . . .
. . . . . . . . . . . .

223
223

. . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . .

Port Group Tables

. . . . . . . . . . . . . . . . . . . .

Pointing Port Table

223

. . . . . . . . . . . . .

Remote Flash BIOS Variable Values

13 Port Group

219

. . . . . . . . . . . . . . . . .

226

229
229
229

Keyboard Port Table

. . . . . . . . . . . . . . . .

232

Processor Port Table

. . . . . . . . . . . . . . . .

235

Memory Device Port Table
Monitor Port Table

. . . . . . . . . . . . .

238

. . . . . . . . . . . . . . . . .

241

Small Computer System Interface (SCSI) Port Table 244
Parallel Port Table
Serial Port Table

. . . . . . . . . . . . . . . . .

246

. . . . . . . . . . . . . . . . . .

250

Universal Serial Bus (USB) Port Table
Port Group Variable Values

14 Device Group .
Device Tables

6

Contents

. . . . . . .

254

. . . . . . . . . . . . . . .

257

. . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . .

263
263

Pointing Device Table

. . . . . . . . . . . . . . .

264

Keyboard Device Table

. . . . . . . . . . . . . . .

266

Processor Device Table
Cache Device Table

. . . . . . . . . .

277

. . . . . . . . . . . . . . . .

279

Memory Device Table

. . . . .

293

. . . . . . . . . . . . . . .

296

. . . . . . . . . . . . . . . . . .

299

Generic Device Table

PCI Device Configuration Space Table
Network Device Table

. . . . . .

302

. . . . . . . . . . . . . . .

305

Managed System Services Device Table
SD Card Unit Table

. . . . .

313

. . . . . . . . . . . . . . . . .

315

SD Card Device Table

System Slot Table

351

. . . . . . . . . . . . . . . . .

351
355

. . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . .

Physical Memory Tables

351

. . . . . . . . . . . . . . . .

System Slot Variable Values

16 Memory Group

322

. . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . .

System Slot Group Table

318

. . . . . . . . . . . . . . .

Device Group Variable Values

15 Slot Group

285

. . . . . . . . . . . . . . .

Memory Device Mapped Address Table .
PCI Device Table

269

. . . . . . . . . . . . . .

Processor Device Status Table

365

. . . . . . . . . . . . . . . .

Physical Memory Array Table

. . . . . . . . . . .

Physical Memory Array Mapped Table
Physical Memory Configuration Table

365
365

. . . . . .

371

. . . . . . .

374

Physical Memory Logging Table

. . . . . . . . . .

377

Redundant Memory Unit Table .

. . . . . . . . . .

379

. . . . . . . . . . .

382

. . . . . . . . . . . .

385

Physical Memory Card Table .
Memory Group Variable Values .

Contents

7

17 BIOS Setup Control Group .
BIOS Setup Control Group Tables

391

. . . . . . . . . . . . .

391

. . . . . . . . . . . . . . . . .

402

Parallel Port Control Table

. . . . . . . . . . . . .

404

. . . . . . . . . . . . . .

406

. . . . . . . . . . . . . . . . .

408

. . . . . . . . . . . . . . . . . .

410

Serial Port Control Table
USB Control Table
IDE Control Table

Diskette Control Table

. . . . . . . . . . . . . . .

Network Interface Control Table
BIOS Setting Table

414

. . . . . . . . . . . . . . . . .

417

. . . . . . . . . . . . . .

18 Local Response Agent Group
LRA Global Settings

. . . . . . . . . . . . . . . .

431
431
431
432

. . . . . . . . . . . . . . . . . .

434

Local Response Agent Variable Values

19 Cost of Ownership Group
Cost of Ownership Table

436

439

. . . . . . . . . . . .

439

. . . . . . . . . . . . . .

439

COO Service Contract Table

. . . . . . . . . . . .

450

. . . . . . . . . . . . .

452

. . . . . . . . . . . . . . . .

454

COO Cost Event Log Table
COO Warranty Table

. . . . . . . . .

. . . . . . . . . . .

Cost of Ownership Group Tables

COO Lease Information Table

. . . . . . . . . . .

456

COO Schedule Number Table

. . . . . . . . . . .

459

. . . . . . . . . . . . . . . . .

460

COO Options Table

COO Maintenance Table

Contents

420

. . . . . . . . . . . . .

LRA Global Settings Table

8

. . . . . . . .

. . . . . . . . . . . . . . . . . . . .

LRA Action Table

412

. . . . . . . . . .

BIOS Group Variable Values

LRA Group Tables

391

. . . . . . . . . . . .

BIOS Setup Control Table
SCSI Control Table

. . . . . . . . . .

. . . . . . . . . . . . . .

462

COO Repair Table .

COO Trouble Ticket Table

. . . . . . . . . .

466

. . . . . . . . . . . . .

468

Cost of Ownership Variable Values

20 Remote Access Group .
DRAC 4 and DRAC 5

470

. . . . . . . . . . .

. . . . . . . . . . . . .

473
473

. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .

473

. . . . . . . . . . . . . . . . . . . . . . . . .

479

Remote Access Table
DRAC III

464

. . . . . . . . . . . . . . . . .

COO Support Information Table

Remote Access Table

. . . . . . . .

489

. . . . . . . . . . . . .

497

. . . . . . . . . . . . . . .

502

Remote SNMP Trap Table
Remote Dial-Up Table

. . . . .

506

. . . . . . . . . . . . . . .

509

Remote User Dial-In Configuration Table
Remote Dial-Out Table

Remote Access Variable Values

21 Cluster Group
Cluster Group

480

. . . . . . . . . . . . . . .

Remote User Administration Table .

512

. . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . .

529

. . . . . . . . . . . . . . . . . . . . . .

Cluster Table

. . . . . . . . . . . . . . . . . . . .

Cluster Group Variable Values

. . . . . . . . . . . . .

529
529
532

22 Baseboard Management Controller Group 533
Baseboard Management Controller Group Tables
Baseboard Management Controller Table .

. . .

533

. . . .

533

Baseboard Management Controller Serial Interface Table 537
Baseboard Management Controller LAN Interface Table 541
Baseboard Management Controller Group Variable Values 545

Contents

9

23 Field Replaceable Unit Group
Field Replaceable Unit Group Tables
Field Replaceable Unit Table

. . . . . . . .

. . . . . . . . . .

549

. . . . . . . . . . . .

549

Field Replaceable Unit Group Variable Values

24 Storage Management Group
Storage Management Group

. . . . .

. . . . . . . . .

. . . . . . . . . . . . . .

553

555
555

. . . . . . . .

557

. . . . . . . . . . . . . . . . . . . .

558

Storage Management Information Group
Global Data Group

549

Physical Devices Group

. . . . . . . . . . . . . . . . .

564

. . . . . . . . . . . . . . . . . .

565

. . . . . . . . . . . . . . . . . . .

589

Controller Table .
Channel Table

Enclosure Table .

. . . . . . . . . . . . . . . . . .

594

Array Disk Table

. . . . . . . . . . . . . . . . . .

605

Array Disk Enclosure Connection Table

. . . . . .

623

. . . . . . .

626

. . . . . . . . . . . . . . . . . . . . . .

628

Array Disk Channel Connection Table
Fan Table

Fan Connection Table
Power Supply Table

. . . . . . . . . . . . . . .

635

. . . . . . . . . . . . . . . .

637

Power Supply Connection Table
Temperature Probe Table

. . . . . . . . . .

642

. . . . . . . . . . . . .

644

Temperature Probe Connection Table
Enclosure Management Module Table

. . . . . . .

650

. . . . . .

652

Enclosure Management Module Connection Table 657
Battery Table

. . . . . . . . . . . . . . . . . . . .

Battery Connection Table
Logical Devices Group
Virtual Disk Table

667

. . . . . . . . . . . . . . . . .

669

. . . . . . . . . . . . . . . . . .

669

Array Disk Logical Connection Table .
Storage Management Event Group

10

Contents

660

. . . . . . . . . . . . .

. . . . . . .

680

. . . . . . . . . . .

682

25 Change Management Group
Inventory Group
Device Group

. . . . . . . . .

685

. . . . . . . . . . . . . . . . . . . . .

685

. . . . . . . . . . . . . . . . . . . . . .

686

. . . . . . . . . . . . . . . .

686

. . . . . . . . . . . . . . . . . . . .

688

Device Group Table
Application Group

. . . . . . . . . . . . . .

689

. . . . . . . . . . . . . . . .

691

Application Group Table
Operating System Group

Inventory Collector Product Information

692

. . . . . . . .

26 Dell Remote Access Controller Out-of-Band Group
695
Product Information
Chassis Status .

. . . . . . . . . . . . . . . . . . .

695

. . . . . . . . . . . . . . . . . . . . .

699

. . . . . . . . . . . . . . .

708

. . . . . . . . . . . . . . . . . . . . .

709

DRsCMCChangeTime
Chassis Power .

CMC Power Information .

. . . . . . . . . . . . . . . .

710

. . . . . . . . . . . . . . . . . .

714

. . . . . . . . . . . . . . . . . . . . . .

716

CMC PSU Information
Chassis Alerts

Legacy Alerting

27 Traps

718

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . .

Understanding the Trap Description

. . . . . . . . . .

723

. . . . . . . . . . . . . .

727

. . . . . . . . . . . . . . . . . .

728

Understanding Trap Severity
Instrumentation Traps

721

Miscellaneous Traps

. . . . . . . . . . . . . . . .

Temperature Probe Traps
Cooling Device Traps .

729

. . . . . . . . . . . . .

731

. . . . . . . . . . . . . . .

733

Contents

11

Voltage Probe Traps

. . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .

737

Chassis Intrusion Traps

. . . . . . . . . . . . . .

739

Redundancy Unit Traps .

. . . . . . . . . . . . . .

740

. . . . . . . . . . . . . . . .

742

. . . . . . . . . . . . . . .

743

. . . . . . . . . . . . . . . .

744

Power Supply Traps
Memory Device Traps
Fan Enclosure Traps

AC Power Cord Traps .
Hardware Log Traps

. . . . . . . . . . . . . . .

746

. . . . . . . . . . . . . . . .

747

Processor Device Status Traps

. . . . . . . . . .

747

. . . . . . . . . . . . . .

749

. . . . . . . . . . . . . . . . . . . .

750

Pluggable Device Traps
Battery Traps

SD Card Device Traps

. . . . . . . . . . . . . . .

751

RAC Traps

. . . . . . . . . . . . . . . . . . . . . . . .

752

BMC Traps

. . . . . . . . . . . . . . . . . . . . . . . .

757

28 Storage Management Alert Reference
Alert Monitoring and Logging
Viewing Alerts

763
763

. . . . . . . . . . . . . . . . . . . . .

764

. . . . . . . . . . . . . . . . . .

SNMP Support for Storage Management Alerts

764

. . . .

765

. . . . . . . . . . . . . .

765

SNMP Trap Definitions

. . . . . . . . . . . . . . .

766

SNMP Trap Variables .

. . . . . . . . . . . . . . .

766

. . . . . . . . . . . . . . . . . .

767

SNMP Trap Forwarding

Viewing SNMP Traps

Alert Descriptions and Corrective Actions

29 iDRAC7 MIB

. . . . . . .

. . . . . . . . . . . . . . . . . . . . . .

Supported Systems

Contents

.

. . . . . . . . . . . . . .

Alert Severity Levels

12

735

Amperage Probe Traps

. . . . . . . . . . . . . . . . . . .

767

769
769

Blade Servers

iDRAC7 Out-of-Band Group

. . . . . . . . . . .

770

. . . . . . . . . . . . . . .

770

. . . . . . . . . . . . . .

770

RAC Information Group

Chassis Information Group .

. . . . . . . . . . . .

772

. . . . . . . . . . . . .

773

. . . . . . . . . . . . . . . . . . . .

776

. . . . . . . . . . . . . . . . . . . . . .

777

System Information Group
Status Group

Trap Variables

778

. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . .

779

Storage Trap Group

. . . . . . . . . . . . . . . .

791

Updates Trap Group

. . . . . . . . . . . . . . . .

796

. . . . . . . . . . . . . . . . . .

796

System Trap Group

Audit Trap Group

Configuration Trap Group

Common Data Types

801

. . . . . .

801

. . . . . . . . . . . . . . . . . . .

Variables with Data Types of State Capabilities and
State Capabilities Unique . . . . . . . . . . . . . . .

.

802

. . . . . . . . . . . . . . . . .

804

. . . . . . . . . . . . . . . . . . . . . . . .

805

Dell Status Data Types
Dell Date .

797

. . . . . . . . . . . . .

A Standard Data Type Definitions

Full Dates

806

. . . . . . . . . . . . . . . . . . . . . .

B SNMP Sample Output
Index

769

. . . . . . . . . . . . . .

iDRAC7 Supported SNMP Versions

iDRAC7 Traps

769

. . . . . . . . . . . . . . . . . . .

Rack and Tower Servers

. . . . . . . . . . . . . .

807

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

813

Contents

13

14

Contents

Contents

15

16

Contents

1

Introduction

This reference guide provides information about the Simple Network
Management Protocol (SNMP) Management Information Base (MIB) which
is applicable for Dell OpenManage Version 7.1.
NOTE: This guide contains information that may also be applicable to earlier
OpenManage supported platforms.
This introduction is divided into two sections. The first section,
"Introduction to the SNMP Reference Guide" on page 18, explains the SNMP
Reference Guide design. All essential Simple Network Management Protocol
(SNMP) terms are defined in this section. Some of the vocabulary may seem
complex and unfamiliar to system administrators who are using SNMP for the
first time. SNMP experts can skim this section, and beginners can read the
section more carefully.
The second section, "Introduction to the Server Administrator
SNMP Subagent" on page 33, is a more technical introduction to the
management information base (MIB) that underlies Server Administrator
services.

Supported SNMP Versions
Operating System Supported OMSA SNMP version
Windows

SNMP v1

Linux

SNMP v1

Introduction

17

Introduction to the SNMP Reference Guide
This reference guide provides a formatted version of the following
Management Information Base that are released with the current version of
Dell OpenManage.
Sections in this guide follow MIB groups and provide explanations and
definitions for the terms used to define MIB objects. Content in this reference
guide is organized as documented in the following subsections.

General Content
Table 1-1 describes the sections that provide general information about the
MIBs documented in this guide.
Table 1-1. General Content Sections in This Guide
Section

Topics

MIB Group
Number

1

Introduction to SNMP basics and to the MIBs that
support Server Administrator services

NA

26

Traps — describes in-band traps defined in the Server 5000
Administrator Instrumentation MIB and out-of-band
traps sent by the Remote Access Controller (RAC)
and Baseboard Management Controller (BMC).

Appendix A

Standard Data Type Definitions — defines standard
data types used in this reference guide.

NA

Appendix B

SNMP Sample Output — provides a sample SNMP
output.

NA

Server Administrator Instrumentation MIB
The Server Administrator Instrumentation MIB (filename 10892.mib) provides
instrumentation data that allows you to monitor the health of a system with
SNMP management applications. It provides:

18

•

Information about the status of temperatures, power supplies, voltages,
currents, fans, and memory at key points in the system

•

Rapid access to detailed fault and performance information gathered by
industry standard systems management agents

•

Version information for Basic Input/Output System (BIOS), firmware,
and operating system
Introduction

•

A detailed account of every cost of ownership (COO) detail about your system

In addition, traps are sent to report a change in status of the health of critical
components.
The Server Administrator Instrumentation MIB structures its MIB objects
into groups of scalar objects or MIB tables that provide related information.
Table 1-2 describes each Server Administrator Instrumentation MIB group
and lists the MIB group number assigned to the MIB group.
The Server Administrator Instrumentation MIB groups are identified
by the SNMP OID 1.3.6.1.4.1.674.10892.1.,
where  is the MIB group number assigned to the
MIB group. See the relevant section for more information about the
MIB objects defined in a MIB group.
Table 1-2. Server Administrator Instrumentation MIB Sections in This Guide
Section Topics

MIB Group
Numbers

2

Instrumentation MIB Version Group — defines version
numbers of the Instrumentation MIB

1

3

Systems Management Software Group — defines information
about the systems management software and the supported
systems management standards

100

4

System State Group — defines status, state, and redundancy for 200
a system and its components

5

Chassis Information Group — defines chassis types, events, and 300
indicators

6

Operating System Group — defines variables for name, version, 400
service pack, and other information about a system’s operating
system

7

System Resource Group — defines variables for input/output
ports, memory, interrupts, and direct memory access

500

8

Power Group — defines variables for power units, power
supplies, and their current and voltage probes

600

9

Thermal Group — defines variables for temperature probes and 700
cooling devices

Introduction

19

Table 1-2. Server Administrator Instrumentation MIB Sections in This Guide
Section Topics

MIB Group
Numbers

10

User Security Group — defines variables for creating and
modifying user accounts

800

11

Remote Flash BIOS Group — defines variables for updating the 900
system’s BIOS remotely

12

Port Group — defines variables for major port types such as
keyboard, monitor, small computer system interface (SCSI),
Universal Serial Bus (USB), and parallel and serial ports

1000

13

Device Group — defines variables for pointing, keyboard,
processor, cache, memory, and personal computer interface
devices

1100

14

Slot Group — defines variables for the system’s slots

1200

15

Memory Group — defines variables for the system’s
physical memory

1300

16

BIOS Setup Control Group — defines variables for BIOS
functions such as boot sequence, speakers, Wake on the local
area network (LAN), diskettes, ports, and
network interface controllers (NIC)

1400

17

Local Response Agent Group — defines variables for global
settings and actions. These variables allow users to
predetermine how the system responds to a particular
type of event

1500

18

Cost of Ownership Group — defines variables for tracking data 1600
on the system’s service contract, lease, repair records, trouble
tickets, and so on

20

Cluster Group — defines variables for systems that operate as a 1800
cluster

21

Baseboard Management Controller Group — provides
information about the Baseboard Management Controller
(BMC) that may be present in your system. In addition to
providing general information about the BMC, this group
provides information about the serial and local area network
(LAN) interfaces of the BMC

20

Introduction

1900

Table 1-2. Server Administrator Instrumentation MIB Sections in This Guide
Section Topics
26

MIB Group
Numbers

Traps — defines the types of alerts that can be sent to report the 5000
status of critical components

Server Administrator Remote Access MIB
The Server Administrator Remote Access MIB (filename dcs3rmt.mib)
provides in-band information about remote access hardware that may be
present in your system.
The Server Administrator Remote Access MIB structures its MIB objects into
groups of scalar objects or MIB tables that provide related information.
Table 1-3 describes each Server Administrator Remote Access MIB group and
lists the MIB group number assigned to the MIB group. The Server
Administrator Remote Access MIB groups are identified by the SNMP OID
1.3.6.1.4.1.674.10892.1. where  is
the MIB group number assigned to the MIB group. See the relevant section
for more information about the MIB objects defined in a MIB group.
Table 1-3. Server Administrator Remote Access MIB Sections in This Guide
Section

Topic

MIB Group
Numbers

19

Remote Access Group — provides information about remote 1700
access hardware that may be present in your system and defines
variables for administrative users, SNMP trap destinations,
modem configuration for dial-up networking, dial-in
configuration, and dial-out destinations

Server Administrator Baseboard Management Controller, ASF MIB
The Server Administrator BMC MIB (filename DcAsfSrv.mib) provides
information about the traps sent by BMC. The Server Administrator BMC
MIB structures its MIB objects that provide related information. The BMC
MIB groups are identified by the SNMP OID 1.3.6.1.4.1.3183.1.1.. The BMC MIB adheres to ASF 2.0 standard and hence the
enterprise ID is wired for management (3183).

Introduction

21

Server Administrator Field Replaceable Unit MIB
The Server Administrator Field Replaceable Unit MIB (filename
dcs3fru.mib) provides information about field replaceable unit (FRU)
hardware that may be present in your system.
The Server Administrator Field Replaceable Unit MIB structures its MIB
objects into groups of scalar objects or MIB tables that provide related
information. Table 1-4 describes each Server Administrator Field Replaceable
Unit MIB group and lists the MIB group number assigned to the MIB group.
The Server Administrator Field Replaceable Unit MIB groups are identified
by the SNMP OID 1.3.6.1.4.1.674.10892.1. where
 is the MIB group number assigned to the MIB group.
See the relevant section for more information about the MIB objects defined
in a MIB group.
Table 1-4. Server Administrator Field Replaceable Unit MIB Sections in This Guide
Section

Topic

MIB Group
Numbers

22

Field Replaceable Unit Group — provides information about 2000
field replaceable units that may be present in your system

Server Administrator Storage Management MIB
The Server Administrator Storage Management MIB (filename dcstorag.mib)
provides storage management data that allows you to monitor the health of
storage resources with SNMP management applications.
Table 1-5 describes each Server Administrator Storage Management MIB
group and lists the MIB group number assigned to the MIB group. The Server
Administrator Storage Management MIB groups are identified by the SNMP
OID 1.3.6.1.4.1.674. where  is
the MIB group number assigned to the MIB group. See the relevant section
for more information about the MIB objects defined in a MIB group.

22

Introduction

Table 1-5. Server Administrator Storage Management MIB Sections in This Guide
Section

Topics

MIB Group
Numbers

23

Storage Management Group — consists of definitions for the 10893
following MIB groups:
• Storage Management Group
• Storage Management Information Group
• Global Data Group
• Physical Devices Group
• Logical Devices Group
• Storage Management Event Group

27

Storage Management Alert Reference — lets you monitor the NA
health of storage resources such as controllers, connectors,
array disks, and virtual disks

Server Administrator Change Management MIB
The Server Administrator Change Management MIB (filename dellcm.mib)
provides management data that allows you to monitor the inventory of devices
and applications with SNMP management applications.
Table 1-6 describes each Server Administrator Change Management MIB
group and lists the MIB group number assigned to the MIB group. The Server
Administrator Change Management MIB groups are identified by the SNMP
OID 1.3.6.1.4.1.674. where  is
the MIB group number assigned to the MIB group. See the relevant section
for more information about the MIB objects defined in a MIB group.
Table 1-6. Server Administrator Change Management MIB Sections in This Guide
Section

Topics

MIB Group
Number

24

Change Management Group - describes the inventory data 10899
provided by the Change Management MIB that allows users
to monitor devices and software present on a particular
managed computer chassis

Introduction

23

Dell Remote Access Controller Out-of-Band MIB
The Dell Remote Access Controller Out-of-Band MIB (filename
dellRAC.mib) provides management data that allows you to monitor the
Chassis Management Controller. This MIB also contains information on RAC
legacy alerting. Table 1-7 describes each Dell RAC Out-of-Band group and
lists the MIB group number assigned to the MIB group. See the relevant
section for more information about the MIB objects defined in a MIB group.
Table 1-7. Dell RAC Out-of-Band MIB
Section
Topics
25

MIB Group
Number

The Dell RAC Out-of-Band MIB consists of information for 2
the following groups:
• "Product Information" on page 695
• "Chassis Status" on page 699
• "Chassis Power" on page 709
• "CMC Power Information" on page 710
• "CMC PSU Information" on page 714
• "Chassis Alerts" on page 716
• "Legacy Alerting" on page 718

How This Guide Defines Technical Terms
The following table provides information about where to find definitions for
technical terms in this reference guide.
Table 1-8. Where to Find Definitions for Technical Terms
Type of Definition

See

Basic SNMP vocabulary.

"Introduction" on page 17

MIB-group-specific variable values.
Sections 3, 5, 7, 8, 9, and 11
MIB-group-specific MIB variables contain links to the through 18.
tables that define these values in the last section of
the section in which these variables are used.
Systems management terms, acronyms, and
commonly managed components referred to in this
reference guide.

24

Introduction

Glossary available on the Dell
Support website at
support.dell.com/manuals.

Table 1-8. Where to Find Definitions for Technical Terms (continued)
Type of Definition

See

Server Administrator-standard data types that specify Appendix A, "Standard Data
variable values in this reference guide.
Type Definitions" on
page 801.

SNMP Basic Terminology
It is important to have a good understanding of the key technical terms used
in this guide. This guide provides definitions for all essential terms used in
describing the Server Administrator MIBs. For definitions on all essential
terms and acronyms, see the Glossary available on the Dell Support website at
support.dell.com/manuals.
SNMP Master Agent

Typically, the SNMP agent on a managed system consists of one SNMP
master agent and zero or more SNMP extension agents. This SNMP agent
extendable structure facilitates the addition of new MIB modules without
having to rebuild the entire SNMP agent and is invisible to
SNMP management applications.
The SNMP master agent is responsible for receiving SNMP request protocol
messages from SNMP management applications and sending SNMP response
protocol messages. As part of processing SNMP request protocol messages,
the SNMP master agent typically communicates with one or more SNMP
extension agents. This communication does not involve standard SNMP
protocol messages. The SNMP master agent uses an extension protocol that
shields the SNMP extension agent from the standard SNMP protocol
messages. The extension protocol also provides a way for SNMP extension
agents to send SNMP event notifications (called traps in SNMPv1).
The SNMP master agent is also responsible for sending SNMP event
notification protocol messages to SNMP management applications.
On supported operating systems, the SNMP master agent is provided with
the operating system. For example, on supported Microsoft Windows
operating systems, the Windows SNMP service is the SNMP master agent.
For information on the versions of the SNMP protocol supported by the
SNMP master agent, see the operating system documentation.

Introduction

25

SNMP Extension Agent

The SNMP extension agent is responsible for registering the MIB objects that
it supports with the SNMP master agent and then processing requests from
the SNMP master agent for those MIB objects. The SNMP extension agent
also initiates event notifications to the SNMP master agent. The SNMP
extension agent does not receive or send standard SNMP protocol messages.
The SNMP extension agent communicates with the SNMP master agent using
an extension protocol defined by the SNMP master agent. The Server
Administrator SNMP subagent is an SNMP extension agent.
Managed Object

A managed object is any item in a computer system that can be singled out
for discovery, monitoring, or user intervention and correction.
NOTE: Not all managed objects described in this guide are supported by all systems.
MIB

A MIB acts as a structured road map for managed objects. As an Application
Programming Interface (API), a MIB allows systems management tools to
retrieve data maintained by an agent. The server administrator MIB is divided
into several major groups of managed objects.
Variable

A variable is a component of a managed object. A temperature probe, for
example, has a variable to describe its capabilities, its health or status,
and certain indexes that you can use to locate specific temperature probes.
One index for the probe would be the probe’s chassis number. Some systems
may have multiple chassis—one chassis for the central processing unit and
another chassis for storage. A chassis within a system can also have more than
one temperature probe. Variables for a temperature probe include its
capabilities, status, chassis index, and index.
One-Based Index

When an index is one-based, counting starts at 1. One-based indexing counts
the first instance as 1, the second index as 2, and so on.

26

Introduction

Zero-Based Index

When an index is zero-based, counting starts at 0. Zero-based indexing
counts the first instance as 0, the second index as 1, and so on.
Fields

Managed object variables contain fields. In this reference guide, managed
object variables have the following fields defined:
Name is the exact string by which the variable is known in the MIB.
MIB variables are named according to the following conventions:
•

Variable names start with a lowercase letter.

•

Spaces are not allowed between words in the variable name.

•

Acronyms are in uppercase letters, except when an acronym is the first
word in the variable name.

•

With the exception of the first letter of the variable name and acronyms,
all other words in the variable name start with capital letters.

The following variable names illustrate these conventions:
•

temperatureProbeLowerCriticalThreshold

•

coolingUnitIndex

•

pCIDeviceSpeed

Object Identifier (OID) is the unique number assigned to an object defined
in a MIB. An OID is written as a sequence of subidentifiers in decimal
notation. Each OID in this reference guide has a prefix that identifies the
managed objects as belonging to Dell: 1.3.6.1.4.1.674. The additional
numbers identify the MIB group and subgroup as well as the table entry
number of any variables.
For example, the OID for the temperature probe managed object table is
700.20 and the variable for the location of the temperature probe
(temperatureProbeLocationName) has an OID of 700.20.1.8. The full OIDs
for these items are 1.3.6.1.4.1.674.10892.1.700.20 for the
temperatureProbeTable and 1.3.6.1.4.1.674.10892.1.700.20.1.8 for the
temperatureProbeLocation. For more information about the structure of
OIDs, see "SNMP Management Information Base Object Identifiers" on
page 35.

Introduction

27

Description is a brief explanation of what a particular managed object does.
Syntax defines the data type in which the values of the variable must be
expressed. Most variables in this reference guide use standard data types such
as string or boolean. All data types that are unique to server administrator
variables are defined at the end of the section in which they occur. Standard
data types are defined in "Standard Data Type Definitions" on page 801.
Access specifies whether persons with administrative privileges can read but not
modify the value of a variable (read only) or can both read and modify the value
of a variable (read-write).

Frequently Used Terms in Variable Names
The following terms are frequently used in the name of a MIB variable:
Capability refers to the actions an object can perform, or to actions that can
be taken by the object. Hot-pluggable is an example of a capability. If a card is
hot-pluggable, it can be replaced while a system is running. Capability settings
refer to the capabilities of the object that the user can select from and activate
if desired. Capability settings allow users of the server administrator to
predetermine how an object behaves under specific conditions.
Settings are the conditions of a manageable object that determine what
happens when a certain value is detected in a component. For example, a user
can set the upper critical threshold of a temperature probe to 75 degrees
Celsius. If the probe reaches that temperature, the setting causes an alert to
be sent to the management console. Some settings, when reached, can trigger
a system shutdown or other response to prevent damage to the system.
State refers to the condition of an object that has more than one condition.
For example, an object may be in a not ready or in an enabled state.
Status refers to the health of an object or how the object is functioning. For
example, the status of a temperature probe that is measuring acceptable
temperatures would be reported as normal. When the probe begins reading
temperatures that exceed limits set by the user, it reports a critical status.

28

Introduction

Tables
This reference guide contains two types of tables: tables that are used to
organize and define variable values and tables that define MIB objects.
Readers must understand the difference between these two types of tables.
SNMP Tables

Most of the MIB objects defined in this reference guide are organized into
SNMP tables. SNMP tables organize data into two-dimensional structural
arrays. In SNMP, objects that have a relationship to other objects are called
columnar objects. Columnar objects are objects used to form lists and tables.
When a MIB group is divided into one or more discrete tables, the word table
has a technical meaning. An example is the section of this reference guide
entitled Universal Unique Identifier (UUID). The UUID object has a type
and a value that uniquely identifies an object such as a chassis. The table
defines all of the variables that comprise the managed object UUID.
The following table is an example of an SNMP table. The table contains
variables that must occur in a definite sequence. In the example table the
defined variables are UUID Chassis Index, UUID Index, UUID Type, and
UUID Value.
Example SNMP Table

UUID Table

These objects comprise the Server Administrator definitions for the UUID.
Name

uUIDTable

Object ID

1.3.6.1.4.1.674.10892.1.300.20

Description Defines the UUID table.
Syntax

SEQUENCE OF UUIDTableEntry

Access

Not accessible

Introduction

29

UUID Table Entry
Name

uUIDTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.300.20.1

Description Defines the UUID table entry.
Syntax

UUIDTableEntry

Access

Not accessible

Index

uUIDIndex, uUIDchassisIndex

UUID Chassis Index
Name

uUIDchassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.300.20.1.1

Description Defines the index (one-based) of this chassis.
Syntax

DellObjectRange

Access

Read-only

UUID Index
Name

uUIDIndex

Object ID

1.3.6.1.4.1.674.10892.1.300.20.1.2

Description Defines the index of the UUID in a specified chassis.
Syntax

DellObjectRange

Access

Read-only

UUID Type
Name

uUIDType

Object ID

1.3.6.1.4.1.674.10892.1.300.20.1.3

Description Defines the type of the UUID for this chassis.
Syntax

DellUUIDType

Access

Read-only

30

Introduction

UUID Value
Name

uUIDValue

Object ID

1.3.6.1.4.1.674.10892.1.300.20.1.4

Description Defines the value of the UUID for this chassis.
Syntax

Octet String (SIZE[16])

Access

Read-only

Reference Guide Content Tables

NOTE: Variable values are defined for any variable that is Server
Administrator-specific. Industry-standard variable definitions are documented
in "Standard Data Type Definitions" on page 801.
Some of the tables in this guide have no technical significance in SNMP.
These tables are designed to show information in a readable form. The
following table, for example, defines the Server Administrator-specific variable,
DellFanControlCapabilities. The table provides the name of the variable, its data
type, the values that are valid for the variable, and the meaning of each value.
Table 1-9. Example Variable Type Definition Table
Variable Name: DellFanControlCapabilities
Data Type: Integer
Possible Data Values

Meaning of Data Value

unknown(1)

The fan’s capabilities are unknown.

lowSpeedCapable(2)

The fan can be set to low speed.

highSpeedCapable(4)

The fan can be set to high speed.

lowOrhighSpeedCapable(6)

The fan can be set to low or high speed.

This type of table is used throughout the reference guide to list and define
variable values. Tables that explain Server Administrator-specific variable
values are located in the final section of sections that define Server
Administrator-specific variables. In the preceding example, the variable name
is DellFanControlCapabilities. This variable must be expressed as an integer
and has four possible values: unknown, lowSpeedCapable,
highSpeedCapable, and lowOrhighSpeedCapable.

Introduction

31

Section Organization
Sections in this reference guide are based on the Server Administrator MIBs,
so the complexity of each section depends on the complexity of each MIB
group. The first section provides a high-level introduction to the MIB group.
If the group is defined by one or more tables, the second section lists these
tables. The third section documents the variables that comprise the group,
and if applicable, the variables that comprise the tables. The fourth section
contains definitions for any Server Administrator-specific variables that are
used in the section. The following example shows the typical content of these
four sections:
1 BIOS Setup Control Group
This section explains the purpose of the MIB group and summarizes the
major features of the component groups.
2 BIOS Group Tables
If there is more than one SNMP table for a group, this section lists all of
the tables. For this BIOS group example, there are eight tables listed.
In each section, double-clicking any table on the list takes you to that table.
•

BIOS Setup Control Table

•

SCSI Control Table

•

Parallel Port Control Table

•

Serial Port Control Table

•

USB Control Table

•

IDE Control Table

•

Diskette Control Table

•

Network Interface Control Table

3 Variables that make up each table in the group
This section documents the variables for the eight tables that comprise the
BIOS group.

32

Introduction

4 BIOS Variable Values
This section explains any Server Administrator-specific variables and data
types that are used in this section. In the BIOS group example, there are
17 unique, Server Administrator-specific variable meanings. Information on
each Server Administrator-specific variable is presented in a formatted table.

Other Documents You May Need
In addition to this guide, you can access the following guides available on the
Dell Support website at support.dell.com/manuals. On the Manuals page,
click SoftwareSystems Management. Click the appropriate product link
on the right-side to access the documents.
•

The Server Administrator Messages Reference Guide lists the messages that
you can receive on your systems management console or on your operating
system’s event viewer. This guide explains the text, severity, and cause of
each message that the server administrator issues.

•

The Server Administrator CIM Reference Guide documents the Common
Information Model (CIM) provider, an extension of the standard
management object format (MOF) file. The Server-Administrator CIM
provider documents supported classes of management objects.

•

The Glossary provides information on the terms used in this document.

Introduction to the Server Administrator
SNMP Subagent
This guide provides formatted information drawn primarily from the MIB
files written for the Server Administrator services that support the SNMP
protocol.
For each of the variables defined in the MIBs, the following fields are specified:
•

Variable name

•

OID or unique identifying number

•

Description

•

Data type of the variable (for example: integer, string, octet string)

•

Whether the variable is accessible, not accessible, read-only, or read-write

•

Index or indexes, if applicable
Introduction

33

For each MIB group that has unique variable definitions, tables are included
in the last section of the section to explain the meaning of the terms.
Standards for writing MIBs are defined by the Internet Engineering Task
Force (IETF). Structure of Management Information (SMI) is a standard that
specifies the rules for defining the structure and type of managed objects and
events in a MIB. SMIv1 is specified in Request For Comments (RFC) 1155.
The Server Administrator MIB conforms to the SMIv1 standard.
SNMP is a systems management standard originally designed for network
management. SNMP manages much more than networks. Information
Technology (IT) professionals use SNMP for monitoring and managing
computer systems and the various components and peripherals supported by
their systems.
SNMP standards are defined by the Internet Engineering Task Force (IETF).
SNMP version 1 was published in August 1988 and is the most commonly
supported version of SNMP. SNMP version 2 was first published in May 1993,
but has not gained widespread market acceptance. SNMP version 3 was
recently completed and has addressed security issues that exist in version 1.
All SNMP systems consist of one or more managed systems that provide data
through an SNMP agent to a management system. The management system
provides a user interface to view data from the managed systems. The
management system and managed systems communicate over a network
(typically through User Datagram Protocol/Internet Protocol [UDP/IP]).
The management system and a managed system communicate by means of a
common data schema. SNMP MIB files define the structure, type, and values
of the SNMP data. While MIBs can be standardized or enterprise specific,
most operating systems supply SNMP agents for the standard MIB-I and
MIB-II schemas. MIB-I defines a base set of standard management information
for systems implementing the Internet Protocol (IP) suite. MIB-II defines
characteristics of the system, characteristics of network interfaces, and
characteristics of components of the IP on the system. In addition to the
standard MIBs, many hardware vendors have defined MIBs that provide
management data specific to their systems and peripheral devices.
Monitored data can be retrieved through SNMP using the Get command.
Typically, this command requires the host name or IP address of the target
machine as well as the OID of the data to retrieve. Exact details are dependent
on the operating system and the development tools being used to create the
management application. The Get command has a variant known as GetNext.
34

Introduction

SNMP Management Information Base Object Identifiers
Each data class within a Management Information Base (MIB) is defined by
an Object Identifier (OID). OIDs are unique across all MIBs. An OID
consists of a series of digits separated by periods. The OID functions in a
similar fashion to a phone number. The phone number 011-512-471-0000
uniquely identifies a single phone. The phone number can be broken down
into a number of components to uniquely identify a phone. The first
component, 011, is the country code for the United States. The second
component, 512, identifies the area code for central Texas. The third
component, 471, is the phone exchange for a large state university in the city
of Austin. The final component, 0000, is the main switchboard.
There are two main differences between the phone number example and an
actual OID. The first difference is that there are many more components in
an OID, up to 128. The combination of these components is called an OID
prefix. The second difference is that OIDs support the concept of indexes or
keys. The OID prefix specifies the data class but does not specify an instance of
the data within the class. Indexes can be used to identify the instances of a data
class. These indexes are referred to as the OID suffix.
The assignment of values for each OID prefix component can be illustrated
by using a tree structure. The following is an example of an OID assignment:
ROOT
CCITT(0)
ISO(1)
ORG(3)
DOD(6)
INTERNET(1)
MGMT(2)
MIB(1)
EXPERIMENTAL(3)
PRIVATE(4)
ENTERPRISES(1)
DELL
(674)
SNMPv2(6)
Introduction

35

In the preceding example, the OID prefix for the Dell enterprise would be
1.3.6.1.4.1.674.
The numbers in boldface type show the categories and numbers that apply to
Server Administrator. All Server Administrator-defined OIDs consist of
1.3.6.1.4.1.674 followed by additional component values.

SNMP Security
SNMP version 1 has a very limited security mechanism. SNMP agents
support the use of a community string, which is configured at each SNMP
agent and is passed as a part of all SNMP request messages. There is no
verification that the requester is actually a member of the
specified community. As most system and network management data is not
confidential, this limited security is acceptable for Get types of requests. On
the other hand, this security is not acceptable for Set types of operations
where an SNMP request could power off a system, reconfigure a redundant
array of independent disks (RAID) card, and so on. Some vendors have
chosen not to support SNMP Set operations for this reason. Server
Administrator is able to support SNMP Set operations because its SNMP
agents implement a hash/digest mechanism to prevent unauthorized SNMP
Set operations. One limitation of this practice is that only server
administrator-developed SNMP management applications have the capability
to support the hash/digest mechanism.
NOTE: The default SNMP agent configuration usually includes a SNMP community
name such as public. For security reasons, change the SNMP community names
from their default values. For information about changing SNMP community names,
see the Dell OpenManage Server Administrator User’s Guide available on the Dell
Support website at support.dell.com/manuals. For additional guidelines, see the
Securing an SNMP Environment article, dated May 2003, in the Dell Power
Solutions magazine. This magazine is also available at dell.com/powersolutions.
NOTE: Server Administrator provides support to enable or disable SNMP Set
operations. For more information on enabling or disabling SNMP Set operations in
Server Administrator, see the Dell OpenManage Server Administrator User’s Guide
or the Dell OpenManage Server Administrator Command Line Interface
User's Guide on the Dell Support website at support.dell.com/manuals.

36

Introduction

Management Actions
Management actions can be performed using the SNMP Set command.
These actions can consist of configuring a phone number for the system’s
owner, rebooting a system, or changing the asset tag of the system. See the
previous section, "SNMP Security" on page 36, for limitations on Set
operations.

SNMP Traps
SNMP is frequently used to monitor systems for fault conditions such as
temperature violations, hard drive failures, and so on. Management
applications can monitor for these conditions by polling the appropriate
OIDs with the Get command and analyzing the returned data. This method
has its drawbacks. If it is done frequently, significant amounts of network
bandwidth can be consumed. If it is done infrequently, the response to the
fault condition may not occur in a timely fashion. SNMP traps avoid these
limitations of the polling method.
An SNMP trap is an asynchronous event indicating that something
significant has occurred. This is analogous to a pager receiving an important
message, except that the SNMP trap frequently contains all the information
needed to diagnose a fault.
Two drawbacks to SNMP traps are that they are sent using UDP, which is not
a guaranteed delivery mechanism, and that they are not acknowledged by
the receiver.
An SNMP trap message contains the trap’s enterprise OID, the agent IP
address, a generic trap ID, the specific trap ID, a time stamp, and zero or
more variable bindings (varbinds). The combination of an enterprise OID
and a specific trap ID uniquely identifies each Server Administrator-defined
trap. A varbind consists of an OID and its value and provides additional
information about the trap.
In order for a management system to receive SNMP traps from a managed
system, the node must be configured to send traps to the management
system. Trap destination configuration is dependent on the operating system.
When this configuration is done, a management application on the
management system can wait for traps and act on them when received.

Introduction

37

For a list of traps supported by the Server Administrator Instrumentation
Service, see "Instrumentation Traps" on page 696. For information on Server
Administrator Storage Management traps, see "Storage Management Alert
Reference" on page 753.
For a list of traps supported by the Remote Access Controller, see "RAC
Traps" on page 742, "BMC Traps" on page 747 and "iDRAC7 Traps" on page
767.

38

Introduction

Dell OpenManage Server
Administrator Version 7.1

2

This section contains information added or updated for the current release.

What’s New in This Release
Storage Management Group MIB
•

Added MIB table for Controller CacheCade.

•

Added MIB table for Controller Spin Down Configured Drives.

•

Added MIB table for Controller Automatic Power Saving.

•

Added MIB table for Controller Configured Drives SpinUp TimeInterval.

•

Added MIB table for Controller Preserved Cache.

•

Added MIB table for Array Disk Power State.

•

Added MIB table for Array Disk Drive Write Cache.

•

Added MIB table for Array Disk Model Number.

•

Added MIB table for Array Disk Life Remaining.

•

Added MIB table for Array Disk Driver Version.

•

Added MIB table for Array Disk Device Life Status.

•

Added MIB table for Power Supply Connection Firmware Version.

•

Added MIB table for Battery ID.

•

Added MIB table for Battery Learn Mode.

•

Modified the description for Controller Type.

•

Modified the description for Controller Persistent Hot Spare.

•

Modified the description for Controller Spin Down Unconfigured Drives.

•

Modified the description for Controller Spin Down Hot Spare Drives.

•

Modified the description for Channel Bus Type.

•

Modified the description for Enclosure ID.
Updates for Dell OpenManage Server Administrator Version 7.1

•

Modified the description for Array Disk State.

•

Modified the description for Array Disk Bus Type.

•

Modified the description for Array Disk Media Type.

•

Modified the description for Battery Learn State.

•

Modified the description for Virtual Disk Layout.

iDRAC7 MIB
•

Updated the supported server information.

For a list of Platforms, Operating Systems, Browsers support added and
deprecated, refer to the Dell OpenManage Server Administrator Version 7.1
User's Guide and Dell Systems Software Support Matrix Version 7.1 at
support.dell.com/manuals.

40

Dell OpenManage Server Administrator Version 7.1

3

Instrumentation MIB Version Group
The Instrumentation Management Information Base (MIB) Version Group
defines the attributes that identify the version of the Instrumentation MIB
supported by the systems management software.

The mIBMajorVersionNumber, mIBMinorVersionNumber, and
mIBMaintenanceVersionNumber attributes are scalar objects, meaning that
they are not related to other MIB objects and are thus not placed in a table.

Management Information Base Major Version
Number
Name

mIBMajorVersionNumber

Object ID

1.3.6.1.4.1.674.10892.1.1.1.0

Description

Defines the major version number of the version of this MIB
supported by the systems management software. For example,
if the MIB version is 1.2.3, the major version number is 1.
A major version number change indicates a major change in
object functionality.

Syntax

DellUnsigned8BitRange

Access

Read-only

Instrumentation MIB Version Group

41

Management Information Base Minor Version
Number
Name

mIBMinorVersionNumber

Object ID

1.3.6.1.4.1.674.10892.1.1.2.0

Description

Defines the minor version number of the version of this MIB
supported by the systems management software. For example,
if the MIB version is 1.2.3, the minor version number is 2.
A minor revision provides additional support for new objects as
well as problem fixes.

Syntax

DellUnsigned8BitRange

Access

Read-only

Management Information Base Maintenance
Version Number
Name

mIBMaintenanceVersionNumber

Object ID

1.3.6.1.4.1.674.10892.1.1.3.0

Description

Defines the maintenance version number for the version of this
MIB supported by the systems management software.
For example, if the MIB version is 1.2.3, the maintenance
version number is 3.

Syntax

DellUnsigned8BitRange

Access

Read-only

42

Instrumentation MIB Version Group

Systems Management Software
Group

4

The Systems Management Software Group allows users to see information
about the standards and software that are supported by the agent of a
particular managed computer chassis. The Systems Management Software
Group classifies each computer chassis according to the systems management
standard that the agent supports.
Additional objects define the universal resource locator (URL) of the systems
management software and the language in which systems management
information displays. Defining these objects enables users to manage a
system using an internet browser. You can access Server Administrator using
the secure hypertext transfer protocol (https) and a pre-assigned port number
of 1311, or you can specify a port number of your own choosing.
NOTE: Using the Software Server Preferences menu of Server Administrator,
you can bind to either one IP address or to all IP addresses.
To manage a system locally using Server Administrator, type the following in
the address field of your browser: https://localhost:<1311 or user-specified
port number>
To manage a system remotely using Server Administrator, type one of the
following in the address field of your browser:
https://:<1311 or user specified port number> or https://:<1311 or user specified port number>

Systems Management Software
The following objects describe the fields for server administrator systems
management information. The systems management software variables are
scalar objects, meaning that they are not related to other management
information base (MIB) objects and are thus not placed in a table.

Systems Management Software Group

43

Systems Management Software Name
Name

systemManagementSoftwareName

Object ID

1.3.6.1.4.1.674.10892.1.100.1

Description

Defines the systems management software product name.

Syntax

DellString

Access

Read-only

Systems Management Software Version Number Name
Name

systemManagementSoftwareVersionNumberName

Object ID

1.3.6.1.4.1.674.10892.1.100.2

Description

Defines the version number of the systems management
software.

Syntax

DellString

Access

Read-only

Systems Management Software Build Number
Name

systemManagementSoftwareBuildNumber

Object ID

1.3.6.1.4.1.674.10892.1.100.3

Description

Defines the build number of the systems management software.

Syntax

DellUnsigned16BitRange

Access

Read-only

Systems Management Software Description Name
Name

systemManagementSoftwareDescriptionName

Object ID

1.3.6.1.4.1.674.10892.1.100.4

Description

Defines the description of the systems management software.

Syntax

DellString

Access

Read-only

44

Systems Management Software Group

Systems Management Software Supported Protocol
Name

systemManagementSoftwareSupportedProtocol

Object ID

1.3.6.1.4.1.674.10892.1.100.5

Description

Defines the systems management standards (SNMP or CIM)
supported by the systems management software.

Syntax

SMSSupportedTypes (See Table 4-1)

Access

Read-only

Systems Management Software Preferred Protocol
Name

systemManagementSoftwarePreferredProtocol

Object ID

1.3.6.1.4.1.674.10892.1.100.6

Description

Defines the preferred systems management standard for the
systems management software.

Syntax

SMSSupportedTypes (See Table 4-1)

Access

Read-only

Systems Management Software Update Level Name
Name

systemManagementSoftwareUpdateLevelName

Object ID

1.3.6.1.4.1.674.10892.1.100.7

Description

Defines the update level of the system management software.

Syntax

DellString

Access

Read-only

Systems Management Software URL Name
Name

systemManagementSoftwareURLName

Object ID

1.3.6.1.4.1.674.10892.1.100.8

Description

Defines the universal resource locator (URL) of the systems
management software.

Syntax

DisplayString (SIZE (0..1024))

Systems Management Software Group

45

Name

systemManagementSoftwareURLName

Access

Read-only

Systems Management Software Language Name
Name

systemManagementSoftwareLanguageName

Object ID

1.3.6.1.4.1.674.10892.1.100.9

Description

Defines the language of the systems management software.

Syntax

DisplayString (SIZE (0..255))

Access

Read-only

Systems Management Software Global Version Name
Name

systemManagementSoftwareGlobalVersionName

Object ID

1.3.6.1.4.1.674.10892.1.100.10

Description

Defines the global version of the systems management software.

Syntax

DellString

Access

Read-only

Systems Management Software Feature Flags
Name

systemManagementSoftwareFeatureFlags

Object ID

1.3.6.1.4.1.674.10892.1.100.11

Description

Defines the features of the systems management software.

Syntax

SMSFeatureFlags (See Table 4-2)

Access

Read-only

Systems Management Software SNMP Agent Feature Flags
Name

systemManagementSoftwareSNMPAgentFeatureFlags

Object ID

1.3.6.1.4.1.674.10892.1.100.12

Description

Defines the features of the SNMP agent software provided by the
operating system.

46

Systems Management Software Group

Name

systemManagementSoftwareSNMPAgentFeatureFlags

Syntax

SMSSNMPAgentFeatureFlags (See Table 4-3)

Access

Read-only

Systems Management Software Manufacturer Name
Name

systemManagementSoftwareManufacturerName

Object ID

1.3.6.1.4.1.674.10892.1.100.13

Description

Defines the manufacturer of the systems management software.

Syntax

DellString

Access

Read-only

Systems Management Software Variable Values
This section includes definitions of server administrator-specific variable
values used in this section.
Table 4-1. Systems Management Software Supported Standards
Variable Name: SMSSupportedTypes
Data Type: Integer
Possible Data Values

Meaning of Data Value

supportsSNMP(1)

This system supports SNMP.

supportsDMI(2)

This system supports DMI.

supportsSNMPandDMI(3)

This system supports SNMP and DMI.

supportsCIMOM(4)

This system supports CIM.

supportsSNMPandCIMOM(5)

This system supports SNMP and CIM.

Systems Management Software Group

47

Table 4-2. Systems Management Software Feature Flags
Variable Name: SMSFeatureFlags
Data Type: Integer
Possible Data Values

Meaning of Data Value

none(0)

The Systems Management Software
features are not enabled.

webOneToOneManagementPreferred(1) The web 1:1 management preferred
feature is enabled.
Table 4-3. Systems Management Software SNMP Agent Feature Flags
Variable Name: SMSSNMPAgentFeatureFlags
Data Type: Integer
Possible Data Values

Meaning of Data Value

none(0)

The Systems Management Software
SNMP agent features are not enabled.

supportsSparseTables(1)

The SNMP agent supports sparse tables.

48

Systems Management Software Group

5

System State Group

The Management Information Base (MIB) variables presented in this section
enable you to track various attributes that describe the state of the critical
components supported by your system. Components monitored under the
System State Group include power supplies, AC power cords, AC power
switches, and cooling devices, as well as temperature, fan, amperage,
and voltage probes.

System State Group Table
The System State Group defines objects in the System State MIB table.

System State Table
The systemStateGlobalSystemStatus variable provides overall system health
status and includes rolled-up (that is, worst) status for Instrumentation and
Storage. This variable monitors the overall system health status. It reflects
changes to systemStateChassisStatus variable, which represents
Instrumentation health status and agentGlobalSystemStatus (dcstorag.mib),
which represents Storage health status.
The systemStateChassisStatus variable provides the rolled-up health status
for the subsystems associated with the chassis that is represented by the row
in the systemStateTable. Changes to the variables in "List 1" on page 50, each
of which indicates the rolled-up health status of all the components of the
corresponding subsystem, are reflected in systemStateChassisStatus variable.
For example, systemStatePowerSupplyStatusCombined provides the rolledup status of all power supplies for the chassis.
The variables in "List 2" on page 50 provide the health status of each
component of the corresponding subsystem. Each octet of the value
represents a component. If a power supply fails, the corresponding entry in
systemStatePowerSupplyStatusDetails,
systemStatePowerSupplyStatusCombined, systemStateChassisStatus, and
systemStateGlobalSystemStatus transitions to critical.

System State Group

49

List 1

Variables that provide rolled-up health status for all components in associated
subsystem in chassis:
•

systemStatePowerSupplyStatusCombined

•

systemStateVoltageStatusCombined

•

systemStateAmperageStatusCombined

•

systemStateCoolingDeviceStatusCombined

•

systemStateTemperatureStatusCombined

•

systemStateMemoryDeviceStatusCombined

•

systemStateChassisIntrusionStatusCombined

•

systemStateACPowerCordStatusCombined

•

systemStateEventLogStatus

•

systemStatePowerUnitStatusCombined

•

systemStateCoolingUnitStatusCombined

•

systemStateACPowerSwitchStatusCombined

•

systemStateRedundantMemoryUnitStatusCombined

•

systemStateProcessorDeviceStatusCombined

•

systemStateBatteryStatusCombined

•

systemStateSDCardUnitStatusCombined

•

systemStateSDCardDeviceStatusCombined

List 2

Variables that provide health status of each component in associated
subsystem in chassis:

50

•

systemStatePowerSupplyStatusDetails

•

systemStateVoltageStatusDetails

•

systemStateAmperageStatusDetails

•

systemStateCoolingDeviceStatusDetails

•

systemStateTemperatureStatusDetails

•

systemStateMemoryDeviceStatusDetails

System State Group

•

systemStateChassisIntrusionStatusDetails

•

systemStateACPowerCordStatusDetails

•

systemStatePowerUnitStatusList

•

systemStateCoolingUnitStatusList

•

systemStateACPowerSwitchStatusList

•

systemStateRedundantMemoryUnitStatusList

•

systemStateProcessorDeviceStatusList

•

systemStateBatteryStatusList

•

systemStateSDCardUnitStatusList

•

systemStateSDCardDeviceStatusList

System State Table
The following object sets up the System State Table:
Name

systemStateTable

Object ID

1.3.6.1.4.1.674.10892.1.200.10

Description

Defines the System State Table.

Syntax

SEQUENCE OF SystemStateTableEntry

Access

Not accessible

System State Table Entry
Name

systemStateTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.200.10.1

Description

Defines the System State Table entry.

Syntax

SystemStateTableEntry

Access

Not accessible

Index

systemStatechassisIndex

System State Group

51

System State Chassis Index
Name

systemStatechassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.200.10.1.1

Description

Defines the index (one-based) of this chassis.

Syntax

DellObjectRange

Access

Read-only

System State Global System Status
Name

systemStateGlobalSystemStatus

Object ID

1.3.6.1.4.1.674.10892.1.200.10.1.2

Description

Defines the global system status of all chassis being monitored by
this instrumentation instance.

Syntax

DellStatus

Access

Read-only

System State Chassis State
Name

systemStateChassisState

Object ID

1.3.6.1.4.1.674.10892.1.200.10.1.3

Description

Defines the system state of this chassis.

Syntax

DellStateSettings

Access

Read-only

System State Chassis Status

52

Name

systemStateChassisStatus

Object ID

1.3.6.1.4.1.674.10892.1.200.10.1.4

Description

Defines the system status of this chassis.

Syntax

DellStatus

Access

Read-only

System State Group

System State Power Unit State Details
Name

systemStatePowerUnitStateDetails

Object ID

1.3.6.1.4.1.674.10892.1.200.10.1.5

Description

Defines the state of all power units in this chassis. The results are
returned as a binary octet string. Each byte of the octet string
represents the state of a specific power unit. The first byte returned
represents the state of the first power unit, the second byte returned
represents the state of the second power unit, and so on. The bytes
have the same definition type as DellStateSettings.

Syntax

Octet String (Size (1..128))

Access

Read-only

System State Power Unit Status Redundancy
Name

systemStatePowerUnitStatusRedundancy

Object ID

1.3.6.1.4.1.674.10892.1.200.10.1.6

Description

Defines the system status of the power unit(s) in this chassis.

Syntax

DellStatus

Access

Read-only

System State Power Unit Status Details
Name

systemStatePowerUnitStatusDetails

Object ID

1.3.6.1.4.1.674.10892.1.200.10.1.7

Description

Defines the status of all power units in this chassis. The results are
returned as a binary octet string. Each byte of the octet string
represents the status of a specific power unit. The first byte returned
represents the status of the first power unit, the second byte
returned represents the status of the second power unit, and so on.
The bytes have the same definition type as DellStatusRedundancy.

Syntax

Octet String (Size (1..128))

Access

Read-only

System State Group

53

System State Power Supply State Details
Name

systemStatePowerSupplyStateDetails

Object ID

1.3.6.1.4.1.674.10892.1.200.10.1.8

Description

Defines the state of all power supplies in this chassis. The results are
returned as a binary octet string. Each byte of the octet string
represents the state of a specific power supply. The first byte returned
represents the state of the first power supply, the second byte
returned represents the state of the second power supply, and so on.
The bytes have the same definition type as DellStateSettings.

Syntax

Octet String (Size (1..128))

Access

Read-only

System State Power Supply Status Combined
Name

systemStatePowerSupplyStatusCombined

Object ID

1.3.6.1.4.1.674.10892.1.200.10.1.9

Description

Defines the status of all power supplies in this chassis.

Syntax

DellStatus

Access

Read-only

System State Power Supply Status Details
Name

systemStatePowerSupplyStatusDetails

Object ID

1.3.6.1.4.1.674.10892.1.200.10.1.10

Description

Defines the status of all power supplies in this chassis. The results
are returned as a binary octet string, Each byte of the octet string
represents the status of a specific power supply. The first byte
returned represents the status of the first power supply, the second
byte returned represents the status of the second power supply,
and so on. The bytes have the same definition type as DellStatus.

Syntax

Octet String (Size (1..128))

Access

Read-only

54

System State Group

System State Voltage State Details
Name

systemStateVoltageStateDetails

Object ID

1.3.6.1.4.1.674.10892.1.200.10.1.11

Description

Defines the state of all voltage probes in this chassis. The results are
returned as a binary octet string. Each byte of the octet string
represents the status of a specific voltage probe. The first byte returned
represents the status of the first voltage probe, the second byte
returned represents the status of the second voltage probe, and so
on. The bytes have the same definition type as DellStateSettings.

Syntax

Octet String (Size (1..128))

Access

Read-only

System State Voltage Status Combined
Name

systemStateVoltageStatusCombined

Object ID

1.3.6.1.4.1.674.10892.1.200.10.1.12

Description

Defines the status of all voltage probes in this chassis.

Syntax

DellStatus

Access

Read-only

System State Voltage Status Details
Name

systemStateVoltageStatusDetails

Object ID

1.3.6.1.4.1.674.10892.1.200.10.1.13

Description

Defines the status of all voltage probes in this chassis.

Syntax

Octet String (Size (1..128))

Access

Read-only

System State Group

55

System State Amperage State Details
Name

systemStateAmperageStateDetails

Object ID

1.3.6.1.4.1.674.10892.1.200.10.1.14

Description

Defines the state of all current probes in this chassis. The results are
returned as a binary octet string. Each byte of the octet string
represents the status of a specific current probe. The first byte
returned represents the state of the first current probe, the second
byte returned represents the state of the second current probe, and
so on. The bytes have the same definition type as DellStateSettings.

Syntax

Octet String (Size (1..128))

Access

Read-only

System State Amperage Status Combined
Name

systemStateAmperageStatusCombined

Object ID

1.3.6.1.4.1.674.10892.1.200.10.1.15

Description

Defines the status of all amperage probes in this chassis. The result
is returned as a combined status value. The value has the same
definition type as DellStatus.

Syntax

DellStatus

Access

Read-only

System State Amperage Status Details
Name

systemStateAmperageStatusDetails

Object ID

1.3.6.1.4.1.674.10892.1.200.10.1.16

Description

Defines the status of all amperage probes in this chassis. The results
are returned as a binary octet string. Each byte of the octet string
represents the status of a specific amperage probe. The first byte
returned represents the status of the first amperage probe, the
second byte returned represents the status of the second amperage
probe, and so on. The bytes have the same definition type as
DellStatus.

Syntax

Octet String (Size (1..128))

Access

Read-only

56

System State Group

System State Cooling Unit State Details
Name

statesystemStateCoolingUnitStateDetails

Object ID

1.3.6.1.4.1.674.10892.1.200.10.1.17

Description

Defines the state of all cooling units in this chassis. The results are
returned as a binary octet string. Each byte of the octet string
represents the state of a specific cooling unit. The first byte returned
represents the state of the first cooling unit, the second byte
returned represents the state of the second cooling unit, and so on.
The bytes have the same definition type as DellStateSettings.

Syntax

Octet String (Size (1..128))

Access

Read-only

System State Cooling Unit Status Redundancy
Name

systemStateCoolingUnitStatusRedundancy

Object ID

1.3.6.1.4.1.674.10892.1.200.10.1.18

Description

Defines the state of all cooling units in this chassis.

Syntax

DellStatusRedundancy

Access

Read-only

System State Cooling Unit State Details
Name

systemStateCoolingUnitstateDetails

Object ID

1.3.6.1.4.1.674.10892.1.200.10.1.19

Description

Defines the state of all cooling units in this chassis. The results are
returned as a binary octet string. Each byte of the octet string
represents the state of a specific cooling unit. The first byte returned
represents the state of the first cooling unit, the second byte
returned represents the state of the second cooling unit, and so on.
The bytes have the same definition type as DellStateSettings.

Syntax

Octet String (Size (1..128))

Access

Read-only

System State Group

57

System State Cooling Device State Details
Name

systemStateCoolingDeviceStateDetails

Object ID

1.3.6.1.4.1.674.10892.1.200.10.1.20

Description

Defines the state of all cooling devices in this chassis. The results are
returned as a binary octet string. Each byte of the octet string
represents the state of a specific cooling device. The first byte returned
represents the state of the first cooling device, the second byte
returned represents the state of the second cooling device, and so
on. The bytes have the same definition type as DellStateSettings.

Syntax

Octet String (Size (1..128))

Access

Read-only

System State Cooling Device Status Combined
Name

systemStateCoolingDeviceStatusCombined

Object ID

1.3.6.1.4.1.674.10892.1.200.10.1.21

Description

This attribute defines the cooling device status of all cooling devices
in this chassis. The results is returned as a combined status value.
The value has the same definition type as DellStatus.

Syntax

DellStatus

Access

Read-only

System State Cooling Device Status Details
Name

systemStateCoolingDeviceStatusDetails

Object ID

1.3.6.1.4.1.674.10892.1.200.10.1.22

Description

Defines the status of all cooling devices in this chassis. The results
are returned as a binary octet string. Each byte of the octet string
represents the status of a specific cooling device. The first byte
returned represents the status of the first cooling device, the second
byte returned represents the status of the second cooling device,
and so on. The bytes have the same definition type as DellStatus.

Syntax

Octet String (Size (1..128))

Access

Read-only

58

System State Group

System State Temperature State Details
Name

systemStateTemperatureStateDetails

Object ID

1.3.6.1.4.1.674.10892.1.200.10.1.23

Description

Defines the state of all temperature probes in this chassis.
The results are returned as a binary octet string. Each byte of the
octet string represents the state of a specific temperature probe.
The first byte returned represents the state of the first temperature
probe, the second byte returned represents the status of the second
temperature probe, and so on. The bytes have the same definition
type as DellStateSettings.

Syntax

Octet String (Size(1..128))

Access

Read-only

System State Temperature Status Combined
Name

systemStateTemperatureStatusCombined

Object ID

1.3.6.1.4.1.674.10892.1.200.10.1.24

Description

Defines the status of all temperature probes in this chassis.
The result is returned as a combined status value. The value has the
same definition type as DellStatus.

Syntax

DellStatus

Access

Read-only

System State Temperature Status Details
Name

systemStateTemperatureStatusDetails

Object ID

1.3.6.1.4.1.674.10892.1.200.10.1.25

Description

Defines the status of all temperature probes in this chassis. The first
byte returned represents the status of the first temperature probe,
the second byte returned represents the status of the second
temperature probe, and so on.

Syntax

Octet String (Size(1..128)

Access

Read-only

System State Group

59

System State Memory Device State Details
Name

systemStateMemoryDeviceStateDetails

Object ID

1.3.6.1.4.1.674.10892.1.200.10.1.26

Description

Defines the state of all memory devices in this chassis. The results
are returned as a binary octet string. Each byte of the octet string
represents the state of the specific memory device. The first byte
returned represents the state of the first memory device, the second
byte returned represents the status of the second memory device,
and so on. The bytes have the same definition type as
DellStateSettings.

Syntax

Octet String (Size(1..128)

Access

Read-only

System State Memory Device Status Combined
Name

systemStateMemoryDeviceStatusCombined

Object ID

1.3.6.1.4.1.674.10892.1.200.10.1.27

Description

Defines the status of all memory devices in this chassis.

Syntax

DellStatus

Access

Read-only

System State Memory Device Status Details
Name

systemStateMemoryDeviceStatusDetails

Object ID

1.3.6.1.4.1.674.10892.1.200.10.1.28

Description

Defines the status of all memory devices in this chassis. The results
are returned as a binary octet string. Each byte of the octet string
represents the status of a specific memory device. The first byte
returned represents the status of the first memory device, the
second byte returned represents the status of the second memory
device, and so on. The bytes have the same definition type as
DellStatus.

Syntax

Octet String (Size(1..128)

Access

Read-only

60

System State Group

System State Chassis Intrusion State Details
Name

systemStateChassisIntrusionStateDetails

Object ID

1.3.6.1.4.1.674.10892.1.200.10.1.29

Description

Defines the intrusion state of all intrusion detection devices in this
chassis. The results are returned as a binary octet string. Each byte of
the octet string represents the status of a specific intrusion detection
device. The first byte returned represents the status of the first
intrusion detection device, the second byte returned represents the
status of the second intrusion detection device, and so on. The bytes
have the same definition type as DellStateSettings.

Syntax

Octet String (Size(1..128)

Access

Read-only

System State Chassis Intrusion Status Combined
Name

systemStateChassisIntrusionStatusCombined

Object ID

1.3.6.1.4.1.674.10892.1.200.10.1.30

Description

Defines the intrusion status of all intrusion detection devices in this
chassis. The result is returned as a combined status value. The value
has the same definition type as DellStatus.

Syntax

DellStatus

Access

Read-only

System State Chassis Intrusion Status Details
Name

systemStateChassisIntrusionStatusDetails

Object ID

1.3.6.1.4.1.674.10892.1.200.10.1.31

Description

Defines the intrusion status of all intrusion detection devices in this
chassis. The first byte returned represents the status of the first
intrusion detection device, the second byte returned represents the
status of the second intrusion detection device, and so on.

Syntax

Octet String (Size(1..128))

Access

Read-only

System State Group

61

System State AC Power Switch State Details
Name

systemStateACPowerSwitchStateDetails

Object ID

1.3.6.1.4.1.674.10892.1.200.10.1.32

Description

Defines the individual state of all AC power switches in this chassis.
The first byte returned represents the state of the first AC power
switch, the second byte returned represents the state of the second
AC power switch, and so on.

Syntax

Octet String (Size(1..128))

Access

Read-only

System State AC Power Switch Status Redundancy
Name

systemStateACPowerSwitchStatusRedundancy

Object ID

1.3.6.1.4.1.674.10892.1.200.10.1.33

Description

Defines the overall redundancy status of the AC power switches in
this chassis.

Syntax

DellStatusRedundancy

Access

Read-only

System State AC Power Switch Status Details
Name

systemStateACPowerSwitchStatusDetails

Object ID

1.3.6.1.4.1.674.10892.1.200.10.1.34

Description

Defines the individual status of all AC power switches in this
chassis. The first byte returned represents the status of the first
AC power switch, the second byte returned represents the status of
the second AC power switch, and so on.

Syntax

Octet String (Size(1..128))

Access

Read-only

62

System State Group

System State AC Power Cord State Details
Name

systemStateACPowerCordStateDetails

Object ID

1.3.6.1.4.1.674.10892.1.200.10.1.35

Description

Defines the individual state of all AC power cords for any AC power
switches in this chassis. The first byte returned represents the state
of the first AC power cord, the second byte returned represents the
state of the second AC power cord, and so on.

Syntax

Octet String (Size(1..128))

Access

Read-only

System State AC Power Cord Status Combined
Name

systemStateACPowerCordStatusCombined

Object ID

1.3.6.1.4.1.674.10892.1.200.10.1.36

Description

Defines the overall status of all AC power cords for any AC power
switches in this chassis.

Syntax

DellStatus

Access

Read-only

System State AC Power Cord Status Details
Name

systemStateACPowerCordStatusDetails

Object ID

1.3.6.1.4.1.674.10892.1.200.10.1.37

Description

Defines the individual status of all AC power cords for any
AC power switches in this chassis. The first byte returned represents
the status of the first AC power cord, the second byte returned
represents the status of the second AC power cord, and so on.

Syntax

Octet String (SIZE(1..128))

Access

Read-only

System State Group

63

System State Redundant Memory Unit State Details
Name

systemStateRedundantMemoryUnitStateDetails

Object ID

1.3.6.1.4.1.674.10892.1.200.10.1.38

Description

Defines the state of all redundant memory units in this chassis.
The results are returned as a binary octet string, each byte of the
octet string represents the state of the specific object. The first byte
returned represents the state of the first object, and so on. The bytes
have the same definition type as DellStateSettings.

Syntax

Octet String (Size(1..128))

Access

Read-only

System State Redundant Memory Unit Status Redundancy
Name

systemStateRedundantMemoryUnitStatusRedundancy

Object ID

1.3.6.1.4.1.674.10892.1.200.10.1.39

Description

Defines the overall redundancy status for redundant memory.

Syntax

DellStatusRedundancy

Access

Read-only

System State Redundant Memory Unit Status Details
Name

systemStateRedundantMemoryUnitStatusDetails

Object ID

1.3.6.1.4.1.674.10892.1.200.10.1.40

Description

Defines the status of all redundant memory units in this chassis.
The results are returned as a binary octet string, each byte of the
octet string represents the status of the specific object. The first
byte returned represents the status of the first object, and so on.
The bytes have the same definition type as DellStatusRedundancy.

Syntax

Octet String (Size(1..128))

Access

Read-only

64

System State Group

System State Event Log Status
Name

systemStateEventLogStatus

Object ID

1.3.6.1.4.1.674.10892.1.200.10.1.41

Description

Defines the overall status of this chassis (ESM) event log.

Syntax

DellStatus

Access

Read-only

System State Power Unit Status Combined
Name

systemStatePowerUnitStatusCombined

Object ID

1.3.6.1.4.1.674.10892.1.200.10.1.42

Description

Defines the combined status of all power units of this chassis.

Syntax

DellStatus

Access

Read-only

System State Power Unit Status List
Name

systemStatePowerUnitStatusList

Object ID

1.3.6.1.4.1.674.10892.1.200.10.1.43

Description

Lists the status of each power unit of this chassis. The results are
returned as a binary octet string where each byte of the octet string
represents the status of a power unit. The first byte returned
represents the status of the first power unit, and so on. The bytes
have the same definition type as DellStatus.

Syntax

Octet String (Size(1..128))

Access

Read-only

System State Group

65

System State Cooling Unit Status Combined
Name

systemStateCoolingUnitStatusCombined

Object ID

1.3.6.1.4.1.674.10892.1.200.10.1.44

Description

Defines the combined status of all cooling units of this chassis.

Syntax

DellStatus

Access

Read-only

System State Cooling Unit Status List
Name

systemStateCoolingUnitStatusList

Object ID

1.3.6.1.4.1.674.10892.1.200.10.1.45

Description

Lists the status of each cooling unit of this chassis. The results are
returned as a binary octet string where each byte of the octet string
represents the status of a cooling unit. The first byte returned
represents the status of the first cooling unit, and so on. The bytes
have the same definition type as DellStatus.

Syntax

Octet String (Size(1..128))

Access

Read-only

System State AC Power Switch Status Combined
Name

systemStateACPowerSwitchStatusCombined

Object ID

1.3.6.1.4.1.674.10892.1.200.10.1.46

Description

Defines the combined status of all AC power switches of this
chassis.

Syntax

DellStatus

Access

Read-only

66

System State Group

System State AC Power Switch Status List
Name

systemStateACPowerSwitchStatusList

Object ID

1.3.6.1.4.1.674.10892.1.200.10.1.47

Description

Lists the status of each AC power switch of this chassis. The results
are returned as a binary octet string where each byte of the octet
string represents the status of an AC power switch. The first byte
returned represents the status of the first AC power switch, and so
on. The bytes have the same definition type as DellStatus.

Syntax

Octet String (Size(1..128))

Access

Read-only

System State Redundant Memory Unit Status Combined
Name

systemStateRedundantMemoryUnitStatusCombined

Object ID

1.3.6.1.4.1.674.10892.1.200.10.1.48

Description

Defines the combined status of all redundant memory units of this
chassis.

Syntax

DellStatus

Access

Read-only

System State Redundant Memory Unit Status List
Name

systemStateRedundantMemoryUnitStatusList

Object ID

1.3.6.1.4.1.674.10892.1.200.10.1.49

Description

Lists the status of each redundant memory unit of this chassis.
The results are returned as a binary octet string where each byte of
the octet string represents the status of a redundant memory unit.
The first byte returned represents the status of the first redundant
memory unit, and so on. The bytes have the same definition type as
DellStatus.

Syntax

Octet String (Size(1..128))

Access

Read-only

System State Group

67

System State Processor Device Status Combined
Name

systemStateProcessorDeviceStatusCombined

Object ID

1.3.6.1.4.1.674.10892.1.200.10.1.50

Description

Defines the combined status of all processor devices of this chassis.

Syntax

DellStatus

Access

Read-only

System State Processor Device Status List
Name

systemStateProcessorDeviceStatusList

Object ID

1.3.6.1.4.1.674.10892.1.200.10.1.51

Description

Lists the status of each processor device of this chassis. The results
are returned as a binary octet string where each byte of the octet
string represents the status of a processor device. The first byte
returned represents the status of the first processor device, and so
on. The bytes have the same definition type as DellStatus.

Syntax

Octet String (Size(1..128))

Access

Read-only

System State Battery Status Combined
Name

systemStateBatteryStatusCombined

Object ID

1.3.6.1.4.1.674.10892.1.200.10.1.52

Description

Defines the combined status of all batteries of this chassis.

Syntax

DellStatus

Access

Read-only

System State Battery Status List
Name

systemStateBatteryStatusList

Object ID

1.3.6.1.4.1.674.10892.1.200.10.1.53

68

System State Group

Name

systemStateBatteryStatusList

Description

Lists the status of each battery of this chassis. The results are
returned as a binary octet string where each byte of the octet string
represents the status of a battery. The first byte returned represents
the status of the first battery, and so on. The bytes have the same
definition type as DellStatus.

Syntax

Octet String (Size(1..128))

Access

Read-only

System State SD Card Unit Status Combined
Name

systemStateSDCardUnitStatusCombined

Object ID

1.3.6.1.4.1.674.10892.1.200.10.1.54

Description

Defines the combined status of all SD Card units of this chassis.

Syntax

DellStatus

Access

Read-only

System State SD Card Unit Status List
Name

systemStateSDCardUnitStatusList

Object ID

1.3.6.1.4.1.674.10892.1.200.10.1.55

Description

Lists the status of each SD Card unit of this chassis. The results are
returned as a binary octet string where each byte of the octet string
represents the status of a SD Card unit. The first byte returned
represents the status of the first SD Card unit, and so on. The bytes
have the same definition type as DellStatus.

Syntax

Octet String (Size(1..128))

Access

Read-only

System State SD Card Device Status Combined
Name

systemStateSDCardDeviceStatusCombined

Object ID

1.3.6.1.4.1.674.10892.1.200.10.1.56

Description

Defines the combined status of all SD Card devices of this chassis.

System State Group

69

Name

systemStateSDCardDeviceStatusCombined

Syntax

DellStatus

Access

Read-only

System State SD Card Device Status List
Name

systemStateSDCardDeviceStatusList

Object ID

1.3.6.1.4.1.674.10892.1.200.10.1.57

Description

Lists the status of each SD Card device of this chassis. The results
are returned as a binary octet string where each byte of the octet
string represents the status of a SD Card device. The first byte
returned represents the status of the first SD Card device, and so on.
The bytes have the same definition type as DellStatus.

Syntax

Octet String (Size(1..128))

Access

Read-only

70

System State Group

Chassis Information Group

6

The Chassis Information Group provides information about the type or types
of chassis in your system, as well as information about the light-emitting
diode (LED) indicators and settings for devices on each chassis. Information
is also available about the current date and time displayed on the chassis,
intrusion warnings, watchdog timer, systems management basic input/output
system (SMBIOS), and so on.

Chassis Information Group Tables
The following management information base (MIB) tables define the objects
in the Chassis Information Group:
•

"Chassis Information Table" on page 71

•

"UUID Table" on page 84

•

"POST Log Table" on page 86

•

"Event Log Table" on page 88

•

"System BIOS Table" on page 91

•

"Firmware Table" on page 98

•

"Intrusion Table" on page 101

•

"Baseboard Table" on page 103

Chassis Information Table
The following object sets up the Chassis Information Table.
Name

chassisInformationTable

Object ID

1.3.6.1.4.1.674.10892.1.300.10

Description

Defines the chassis information table.

Syntax

SEQUENCE OF ChassisInformationTableEntry

Access

Not accessible

Chassis Information Group

71

Chassis Information Table Entry
Name

chassisInformationTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.300.10.1

Description

Defines the chassis information table entry.

Syntax

ChassisInformationTableEntry

Access

Not accessible

Index

chassisIndexChassisInformation

Chassis Index Chassis Information
Name

chassisIndexChassisInformation

Object ID

1.3.6.1.4.1.674.10892.1.300.10.1.1

Description

Defines the index (one-based) of this chassis. The first chassis is
numbered one.

Syntax

DellObjectRange

Access

Read-only

Chassis State Capabilities
Name

chassisStateCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.300.10.1.2

Description

Defines the capabilities of the chassis.

Syntax

DellStateCapabilities

Access

Read-only

Chassis State Settings
Name

chassisStateSettings

Object ID

1.3.6.1.4.1.674.10892.1.300.10.1.3

Description

Defines the state settings for the chassis.

Syntax

DellStateSettings

Access

Read-write

72

Chassis Information Group

Chassis Status
Name

chassisStatus

Object ID

1.3.6.1.4.1.674.10892.1.300.10.1.4

Description

Defines the status of the chassis.

Syntax

DellStatus

Access

Read-only

Chassis Parent Index Reference
Name

chassisparentIndexReference

Object ID

1.3.6.1.4.1.674.10892.1.300.10.1.4

Description

Defines the index (one-based) of the parent chassis of this
chassis, if any. A zero (0) means that this chassis is the parent of
all other chassis managed by the Server Administrator.

Syntax

DellObjectRange

Access

Read-only

Chassis Type
Name

chassisType

Object ID

1.3.6.1.4.1.674.10892.1.300.10.1.6

Description

Defines the chassis type.

Syntax

DellChassisType (See Table 6-2)

Access

Read-only

Chassis Name
Name

chassisName

Object ID

1.3.6.1.4.1.674.10892.1.300.10.1.7

Description

Defines the user-assigned chassis name of the chassis.

Syntax

DellString

Access

Read-write

Chassis Information Group

73

Chassis Manufacturer Name
Name

chassisManufacturerName

Object ID

1.3.6.1.4.1.674.10892.1.300.10.1.8

Description

Defines the manufacturer’s name for this chassis.

Syntax

DellString

Access

Read-only

Chassis Model Name
Name

chassisModelName

Object ID

1.3.6.1.4.1.674.10892.1.300.10.1.9

Description

Defines the system model type for this chassis.

Syntax

DellString

Access

Read-only

Chassis Asset Tag Name
Name

chassisAssetTagName

Object ID

1.3.6.1.4.1.674.10892.1.300.10.1.10

Description

Defines the user-assigned asset tag name for this chassis.

Syntax

DisplayString (SIZE (0..10))

Access

Read-write

Chassis Service Tag Name
Name

chassisServiceTagName

Object ID

1.3.6.1.4.1.674.10892.1.300.10.1.11

Description

Defines the service tag name for this chassis.

Syntax

DisplayString (SIZE (0..7))

Access

Read-only

74

Chassis Information Group

Chassis ID
Name

chassisID

Object ID

1.3.6.1.4.1.674.10892.1.300.10.1.12

Description

Defines the asset tag name for this chassis.

Syntax

DellUnsigned8BitRange

Access

Read-only

Chassis ID Extension
Name

chassisIDExtension

Object ID

1.3.6.1.4.1.674.10892.1.300.10.1.13

Description

Defines the SMBIOS machine ID of this chassis.

Syntax

DellUnsigned16BitRange

Access

Read-only

Chassis System Class
Name

chassisSystemClass

Object ID

1.3.6.1.4.1.674.10892.1.300.10.1.14

Description

Defines the chassis class of this chassis.

Syntax

DellChassisSystemClass (See Table 6-21)

Access

Read-only

Chassis System Name
Name

chassisSystemName

Object ID

1.3.6.1.4.1.674.10892.1.300.10.1.15

Description

Defines the system name of this chassis.

Syntax

DellString

Access

Read-only

Chassis Information Group

75

Chassis System Boot Date Name
Name

chassisSystemBootDateName

Object ID

1.3.6.1.4.1.674.10892.1.300.10.1.16

Description

Defines the boot time of this system.

Syntax

DellDateName

Access

Read-only

Chassis System Date Name
Name

chassisSystemDateName

Object ID

1.3.6.1.4.1.674.10892.1.300.10.1.17

Description

Defines the current time on this system.

Syntax

DellDateName

Access

Read-only

Chassis System Location Name
Name

chassisSystemLocationName

Object ID

1.3.6.1.4.1.674.10892.1.300.10.1.18

Description

Defines the user-assigned location for this chassis.

Syntax

DellString

Access

Read-write

Chassis System Primary User Name
Name

chassisSystemPrimaryUserName

Object ID

1.3.6.1.4.1.674.10892.1.300.10.1.19

Description

Defines the user-assigned primary user name for this chassis.

Syntax

DellString

Access

Read-write

76

Chassis Information Group

Chassis System User Phone Number Name
Name

chassisSystemUserPhoneNumberName

Object ID

1.3.6.1.4.1.674.10892.1.300.10.1.20

Description

Defines the user-assigned phone number of the primary user of
the system.

Syntax

DellString

Access

Read-write

Chassis Connection Status Unique
Name

chassisConnectionStatusUnique

Object ID

1.3.6.1.4.1.674.10892.1.300.10.1.21

Description

Defines the status of the connection from the system chassis to
an expansion chassis.

Syntax

DellConnectionStatus (See Table 6-3)

Access

Read-only

Chassis Fan Control Capabilities Unique
Name

chassisFanControlCapabilitiesUnique

Object ID

1.3.6.1.4.1.674.10892.1.300.10.1.22

Description

Defines the capabilities of the fan control function in this chassis.

Syntax

DellFanControlCapabilities (See Table 6-4)

Access

Read-only

Chassis Fan Control Settings Unique
Name

chassisFanControlSettingsUnique

Object ID

1.3.6.1.4.1.674.10892.1.300.10.1.23

Description

Defines the readings and settings of the fan control hardware in
the chassis.

Syntax

DellFanControlSettings

Access

Read-write
Chassis Information Group

77

Chassis LED Control Capabilities Unique
Name

chassisLEDControlCapabilitiesUnique

Object ID

1.3.6.1.4.1.674.10892.1.300.10.1.24

Description

Defines the capabilities of the LED control function in the chassis.

Syntax

DellLEDControlCapabilities (See Table 6-5)

Access

Read-only

Chassis LED Control Settings Unique
Name

chassisLEDControlSettingsUnique

Object ID

1.3.6.1.4.1.674.10892.1.300.10.1.25

Description

Defines the readings and settings of the LED control hardware
in the chassis.

Syntax

DellLEDControlSettings (See Table 6-6)

Access

Read-write

Chassis Hard-Drive (HD) Fault Clear Control Capabilities
Name

chassisHDFaultClearControlCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.300.10.1.26

Description

Specifies whether the chassis allows reset of the chassis
hard-drive fault LED.

Syntax

DellHDFaultLEDControlCapabilities (See Table 6-7)

Access

Read-only

Chassis HD Fault Clear Control Settings
Name

chassisHDFaultClearControlSettings

Object ID

1.3.6.1.4.1.674.10892.1.300.10.1.27

Description

Allows reset of the chassis hard-drive fault LED.

Syntax

DellHDFaultLEDControlSettings (See Table 6-8)

Access

Read-write

78

Chassis Information Group

Chassis Identify Flash Control Capabilities
Name

chassisIdentifyFlashControlCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.300.10.1.28

Description

Specifies whether the chassis front-panel LED can be set to flash.

Syntax

DellChassisIdentifyControlCapabilities (See Table 6-9)

Access

Read-only

Chassis Identify Flash Control Settings
Name

chassisIdentifyFlashControlSettings

Object ID

1.3.6.1.4.1.674.10892.1.300.10.1.29

Description

Causes the chassis front-panel LED to flash.

Syntax

DellChassisIdentifyControlSettings (See Table 6-10)

Access

Read-write

Chassis Lock Present
Name

chassisLockPresent

Object ID

1.3.6.1.4.1.674.10892.1.300.10.1.30

Description

Specifies whether a chassis lock is present on the chassis.

Syntax

DellBoolean

Access

Read-only

Chassis Host Control Capabilities Unique
Name

chassishostControlCapabilitiesUnique

Object ID

1.3.6.1.4.1.674.10892.1.300.10.1.31

Description

Defines the capabilities of the host control object.

Syntax

DellHostControlCapabilities (See Table 6-11)

Access

Read-only

Chassis Information Group

79

Chassis Host Control Settings Unique
Name

chassishostControlSettingsUnique

Object ID

1.3.6.1.4.1.674.10892.1.300.10.1.32

Description

Defines the current settings of the host control object.

Syntax

DellHostControlSettings (See Table 6-12)

Access

Read-write

Chassis Watchdog Control Capabilities Unique
Name

chassiswatchDogControlCapabilitiesUnique

Object ID

1.3.6.1.4.1.674.10892.1.300.10.1.33

Description

Defines the capabilities of the watchdog timer object.

Syntax

DellWatchDogControlCapabilities (See Table 6-13)

Access

Read-only

Chassis Watchdog Control Settings Unique
Name

chassiswatchDogControlSettingsUnique

Object ID

1.3.6.1.4.1.674.10892.1.300.10.1.34

Description

Defines the current settings and the values allowed to be set for
the watchdog timer object.

Syntax

DellWatchDogControlCapabilities (See Table 6-13)

Access

Read-write

Chassis Watchdog Control Expiry Time Capabilities Unique
Name

chassiswatchDogControlExpiryTimeCapabilities
Unique

Object ID

1.3.6.1.4.1.674.10892.1.300.10.1.35

Description

Defines the capabilities of the watchdog expiry timer object.

Syntax

DellWatchDogTimerCapabilities (See Table 6-13)

Access

Read-only

80

Chassis Information Group

Chassis Watchdog Control Expiry Time
Name

chassiswatchDogControlExpiryTime

Object ID

1.3.6.1.4.1.674.10892.1.300.10.1.36

Description

Defines the current reading and allows setting of the nonrecoverable
watchdog expiry timer object.

Syntax

DellUnsigned16BitRange

Access

Read-write

Chassis Allow Set Commands From SNMP
Name

chassisallowSETCommandsfromSNMP

Object ID

1.3.6.1.4.1.674.10892.1.300.10.1.37

Description

Specifies whether Simple Network Management Protocol (SNMP)
Set type commands are allowed by Server Administrator.
This attribute does not reflect whether SNMP Set type commands
are allowed by the SNMP master agent.

Syntax

DellBoolean

Access

Read-only

Chassis Power Button Control Capabilities Unique
Name

chassisPowerButtonControlCapabilitiesUnique

Object ID

1.3.6.1.4.1.674.10892.1.300.10.1.38

Description

Defines the capabilities of the power button control function.

Syntax

DellPowerButtonControlCapabilities (See Table 6-16)

Access

Read-only

Chassis Power Button Control Settings Unique
Name

chassisPowerButtonControlSettingsUnique

Object ID

1.3.6.1.4.1.674.10892.1.300.10.1.39

Description

Defines the current reading and allows setting of the power button
control hardware.

Chassis Information Group

81

Name

chassisPowerButtonControlSettingsUnique

Syntax

DellPowerButtonControlSettings (See Table 6-17)

Access

Read-write

Chassis Reseller Name
Name

chassisResellerName

Object ID

1.3.6.1.4.1.674.10892.1.300.10.1.40

Description

Defines the name of the chassis reseller.

Syntax

DisplayString (SIZE (0..128))

Access

Read-only

Chassis Reseller Contact Information Name
Name

chassisResellerContactInformationName

Object ID

1.3.6.1.4.1.674.10892.1.300.10.1.41

Description

Defines the chassis reseller contact information name.

Syntax

DisplayString (SIZE (0..128))

Access

Read-only

Chassis Reseller Product Name
Name

chassisResellerProductName

Object ID

1.3.6.1.4.1.674.10892.1.300.10.1.42

Description

Defines the chassis reseller product name.

Syntax

DisplayString (SIZE (0..128))

Access

Read-only

Chassis Reseller System ID
Name

chassisResellerSystemID

Object ID

1.3.6.1.4.1.674.10892.1.300.10.1.43

Description

Defines the chassis reseller system ID.

82

Chassis Information Group

Name

chassisResellerSystemID

Syntax

DellUnsigned16BitRange

Access

Read-only

Chassis NMI Button Control Capabilities Unique
Name

chassisNMIButtonControlCapabilitiesUnique

Object ID

1.3.6.1.4.1.674.10892.1.300.10.1.44

Description

Defines the capabilities of the NMI button control function.

Syntax

DellNMIButtonControlCapabilities (See Table 6-18)

Access

Read-only

Chassis NMI Button Control Settings Unique
Name

chassisNMIButtonControlSettingsUnique

Object ID

1.3.6.1.4.1.674.10892.1.300.10.1.45

Description

Defines the current reading and allows setting of the NMI button
control hardware.

Syntax

DellNMIButtonControlSettings (See Table 6-19)

Access

Read-write

Chassis System Properties
Name

chassisSystemProperties

Object ID

1.3.6.1.4.1.674.10892.1.300.10.1.46

Description

Defines the properties of the system.

Syntax

DellSystemProperties (See Table 6-20)

Access

Read-only

Chassis Information Group

83

Chassis System Revision Number
Name

chassisSystemRevisionNumber

Object ID

1.3.6.1.4.1.674.10892.1.300.10.1.47

Description

Defines the revision number of the system where zero indicates the
original version of the system. The revision number is not available
on all systems.

Syntax

DellUnsigned8BitRange

Access

Read-only

Chassis System Revision Name
Name

chassisSystemRevisionName

Object ID

1.3.6.1.4.1.674.10892.1.300.10.1.48

Description

Defines the revision name of the system, if applicable.

Syntax

DellString

Access

Read-only

Chassis Express Service Code Name
Name

chassisExpressServiceCodeName

Object ID

1.3.6.1.4.1.674.10892.1.300.10.1.49

Description

Defines the express service code of the chassis.

Syntax

DellString

Access

Read-only

UUID Table
These objects comprise the server administrator definitions for the
Universal Unique Identifier (UUID).
Name

uUIDTable

Object ID

1.3.6.1.4.1.674.10892.1.300.20

Description

Defines the UUID table.

Syntax

SEQUENCE OF UUIDTableEntry

84

Chassis Information Group

Name

uUIDTable

Access

Not accessible

UUID Table Entry
Name

uUIDTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.300.20.1

Description

Defines the UUID table entry.

Syntax

UUIDTableEntry

Access

Not accessible

Index

uUIDIndex, uUIDchassisIndex

UUID Chassis Index
Name

uUIDchassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.300.20.1.1

Description

Defines the index (one-based) of this chassis.

Syntax

DellObjectRange

Access

Read-only

UUID Index
Name

uUIDIndex

Object ID

1.3.6.1.4.1.674.10892.1.300.20.1.2

Description

Defines the index of the UUID in a specified chassis.

Syntax

DellObjectRange

Access

Read-only

UUID Type
Name

uUIDType

Object ID

1.3.6.1.4.1.674.10892.1.300.20.1.3

Description

Defines the type of the UUID for this chassis.

Chassis Information Group

85

Name

uUIDType

Syntax

DellUUIDType

Access

Read-only

UUID Value
Name

uUIDValue

Object ID

1.3.6.1.4.1.674.10892.1.300.20.1.4

Description

Defines the value of the UUID for this chassis.

Syntax

Octet String (SIZE(16))

Access

Read-only

POST Log Table
This section defines attributes for the power-on self-test (POST) log.
When you turn on your computer, the POST checks various system
components before the operating system loads. The POST tests the
random-access memory (RAM), the hard drives, and the keyboard,
for example. While the POST is running, it makes a log file that system
administrators can view. The variables in this section also contribute to
managing the POST log.
Name

postLogTable

Object ID

1.3.6.1.4.1.674.10892.1.300.30

Description

Defines the POST Log Table.

Syntax

SEQUENCE OF PostLogTableEntry

Access

Not accessible

POST Log Table Entry
Name

postLogTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.300.30.1

Description

Defines the POST Log Table entry.

Syntax

PostLogTableEntry

86

Chassis Information Group

Name

postLogTableEntry

Access

Not accessible

Index

postLogchassisIndex, postLogRecordIndex

POST Log Chassis Index
Name

postLogchassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.300.30.1.1

Description

Defines the index (one-based) of this chassis.

Syntax

DellObjectRange

Access

Read-only

POST Log Record Index
Name

postLogRecordIndex

Object ID

1.3.6.1.4.1.674.10892.1.300.30.1.2

Description

Defines the record number (one-based) of the POST log.

Syntax

DellUnsigned32BitRange

Access

Read-only

POST Log State Capabilities Unique
Name

postLogStateCapabilitiesUnique

Object ID

1.3.6.1.4.1.674.10892.1.300.30.1.3

Description

Defines the capabilities of the object that is writing the POST log.

Syntax

DellStateCapabilitiesLogUnique

Access

Read-only

POST Log State Settings Unique
Name

postLogStateSettingsUnique

Object ID

1.3.6.1.4.1.674.10892.1.300.30.1.4

Description

Defines the state of the object that is writing the POST log.

Chassis Information Group

87

Name

postLogStateSettingsUnique

Syntax

DellStateSettingsLogUnique

Access

Read-write

POST Log Record
Name

postLogRecord

Object ID

1.3.6.1.4.1.674.10892.1.300.30.1.5

Description

Defines the data for the specified chassis and record index in the
POST log being returned.

Syntax

DisplayString (SIZE (0..1024))

Access

Read-only

POST Log Format
Name

postLogFormat

Object ID

1.3.6.1.4.1.674.10892.1.300.30.1.5

Description

Defines format of the POST log.

Syntax

DellLogFormat (See Table 6-1)

Access

Read-only

Event Log Table
Name

eventLogTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.300.40

Description

Defines the Event Log Table.

Syntax

SEQUENCE OF EventLogTableEntry

Access

Not accessible

Event Log Table Entry
Name

eventLogTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.300.40.1

88

Chassis Information Group

Name

eventLogTableEntry

Description

Defines the event Log Table Entry.

Syntax

EventLogTableEntry

Access

Not accessible

Index

eventLogchassisIndex,eventLogRecordIndex

Event Log Chassis Index
Name

eventLogchassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.300.40.1.1

Description

Defines the index (one-based) of this chassis.

Syntax

DellObjectRange

Access

Read-only

Event Log Record Index
Name

eventLogRecordIndex

Object ID

1.3.6.1.4.1.674.10892.1.300.40.1.2

Description

Defines the record index of the event log.

Syntax

DellUnsigned32BitRange

Access

Read-only

Event Log State Capabilities Unique
Name

eventLogStateCapabilitiesUnique

Object ID

1.3.6.1.4.1.674.10892.1.300.40.1.3

Description

Defines the capabilities of the object that is writing the event log.

Syntax

DellStateCapabilitiesLogUnique

Access

Read-only

Chassis Information Group

89

Event Log State Settings Unique
Name

eventLogStateSettingsUnique

Object ID

1.3.6.1.4.1.674.10892.1.300.40.1.4

Description

Defines the state settings for the object that is writing the event log.

Syntax

DellStateSettingsLogUnique

Access

Read-write

Event Log Record
Name

eventLogRecord

Object ID

1.3.6.1.4.1.674.10892.1.300.40.1.5

Description

Defines the data for the specified chassis and log record index in the
event log being returned.

Syntax

DisplayString (SIZE (0..1024))

Access

Read-only

Event Log Format
Name

eventLogFormat

Object ID

1.3.6.1.4.1.674.10892.1.300.40.1.6

Description

Defines the format of the event log.

Syntax

DellLogFormat (See Table 6-1)

Access

Read-only

Event Log Severity Status
Name

eventLogSeverityStatus

Object ID

1.3.6.1.4.1.674.10892.1.300.40.1.7

Description

Defines the severity of the event log record.

Syntax

DellStatus

Access

Read-only

Status

Mandatory

90

Chassis Information Group

Event Log Date Name
Name

eventLogDateName

Object ID

1.3.6.1.4.1.674.10892.1.300.40.1.8

Description

Defines the date and time of the event log record.

Syntax

DellDateName

Access

Read-only

Status

Mandatory

System BIOS Table
This table lists objects that define the system’s basic input/output system (BIOS).
Name

systemBIOSTable

Object ID

1.3.6.1.4.1.674.10892.1.300.50

Description

Defines the System BIOS Table.

Syntax

SEQUENCE OF SystemBIOSTableEntry

Access

Not accessible

System BIOS Table Entry
Name

systemBIOSTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.300.50.1

Description

Defines the System BIOS Table entry.

Syntax

SystemBIOSTableEntry

Access

Not accessible

Index

systemBIOSchassisIndex,systemBIOSIndex

System BIOS Chassis Index
Name

systemBIOSchassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.300.50.1.1

Description

Defines the index (one-based) of this chassis.

Syntax

DellObjectRange
Chassis Information Group

91

Name

systemBIOSchassisIndex

Access

Read-only

System BIOS Index
Name

systemBIOSIndex

Object ID

1.3.6.1.4.1.674.10892.1.300.50.1.2

Description

Defines the index (one-based) of the system BIOS of this object.

Syntax

DellObjectRange

Access

Read-only

System BIOS State Capabilities
Name

systemBIOSStateCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.300.50.1.3

Description

Defines the capabilities of the system BIOS of this object.

Syntax

DellStateCapabilities

Access

Read-only

System BIOS State Settings
Name

systemBIOSStateSettings

Object ID

1.3.6.1.4.1.674.10892.1.300.50.1.4

Description

Defines the state of the system BIOS of this object.

Syntax

DellStateSettings

Access

Read-write

System BIOS Status
Name

systemBIOSStatus

Object ID

1.3.6.1.4.1.674.10892.1.300.50.1.5

Description

Defines the status of the system BIOS of this object.

Syntax

DellStatus

92

Chassis Information Group

Name

systemBIOSStatus

Access

Read-only

System BIOS Size
Name

systemBIOSSize

Object ID

1.3.6.1.4.1.674.10892.1.300.50.1.6

Description

Defines the image size of the system BIOS in kilobytes (KB).
A zero (0) indicates that the image size of the BIOS is unknown.

Syntax

DellUnsigned32BitRange

Access

Read-only

System BIOS Release Date Name
Name

systemBIOSReleaseDateName

Object ID

1.3.6.1.4.1.674.10892.1.300.50.1.7

Description

Defines the release date of the system BIOS.

Syntax

DellDateName

Access

Read-only

System BIOS Version Name
Name

systemBIOSVersionName

Object ID

1.3.6.1.4.1.674.10892.1.300.50.1.8

Description

Defines the version name of the system BIOS.

Syntax

DellString

Access

Read-only

System BIOS Starting Address
Name

systemBIOSStartingAddress

Object ID

1.3.6.1.4.1.674.10892.1.300.50.1.9

Chassis Information Group

93

Name

systemBIOSStartingAddress

Description

Defines the starting address of the system BIOS. A zero (0) indicates
that the address is unknown.

Syntax

DellUnsigned64BitRange

Access

Read-only

System BIOS Ending Address
Name

systemBIOSEndingAddress

Object ID

1.3.6.1.4.1.674.10892.1.300.50.1.10

Description

Defines the ending address of the system BIOS. A zero (0) indicates
that the address is unknown.

Syntax

DellUnsigned64BitRange

Access

Read-only

System BIOS Manufacturer Name
Name

systemBIOSManufacturerName

Object ID

1.3.6.1.4.1.674.10892.1.300.50.1.11

Description

Defines the system BIOS manufacturer’s name.

Syntax

DellString

Access

Read-only

System BIOS Characteristics
Name

systemBIOSCharacteristics

Object ID

1.3.6.1.4.1.674.10892.1.300.50.1.12

94

Chassis Information Group

Name

systemBIOSCharacteristics

Description

Defines characteristics of the system BIOS. This attribute is a bit
field where a bit has the meaning defined below when set to 1 (one).
Bit 63 is the first bit in the value, and bit 0 is the last bit in the value.
See the description of DellUnsigned64BitRange at the beginning of
this file for more information on the format of the value.
Bits 48-63 need to be examined in the context of the system ID.
The system ID is available in the attribute chassisID. If the value for
chassisID is non-zero, bits 48-63 have the meaning defined below:
Bit Position Meaning if Set
-------------- -----------------Bit 0Reserved
Bit 1Reserved
Bit 2Unknown
Bit 3BIOS Characteristics Not Supported
Bit 4ISA is supported
Bit 5MCA is supported
Bit 6EISA is supported
Bit 7PCI is supported
Bit 8PC Card (PCMCIA) is supported
Bit 9Plug and Play is supported
Bit 10APM is supported
Bit 11BIOS is Upgradeable (Flash)
Bit 12BIOS shadowing is allowed
Bit 13VL-VESA is supported
Bit 14ESCD support is available
Bit 15Boot from CD is supported

Chassis Information Group

95

Name

systemBIOSCharacteristics

Description

Bit Position Meaning if Set
-------------- -----------------Bit 16Selectable Boot is supported
Bit 17BIOS ROM is socketed
Bit 18Boot From PC Card (PCMCIA) is supported
Bit 19EDD (Enhanced Disk Drive) Specification is supported
Bit 20Int 13h - Japanese Floppy for NEC 9800 1.2mb (3.5 in,
1k Bytes/Sector, 360 RPM) is supported
Bit 21Int 13h - Japanese Floppy for Toshiba 1.2mb (3.5 in,
360 RPM) is supported
Bit 22Int 13h - 5.25 in / 360 KB Floppy Services are supported
Bit 23Int 13h - 5.25 in /1.2MB Floppy Services are supported
Bit 24Int 13h - 3.5 in / 720 KB Floppy Services are supported
Bit 25Int 13h - 3.5 in / 2.88 MB Floppy Services are supported
Bit 26Int 5h, Print Screen Service is supported
Bit 27Int 9h, 8042 Keyboard services are supported
Bit 28Int 14h, Serial Services are supported
Bit 29Int 17h, Printer Services are supported
Bit 30Int 10h, CGA/Mono Video Services are supported
Bit 31NEC PC-98
Bit 32-47Reserved
Bit 48Built-in NIC supports Magic Packet
Bit 49System supports Wake-on-LAN
Bit 50System supports chassis intrusion
Bit 51Built-in NIC supports pattern-matching
Bit 52System BIOS supports a 7-character service tag
Bit 53-63Reserved

Syntax

DellUnsigned64BitRange

System BIOS Characteristics Ext 1
Name

systemBIOSCharacteristicsExt1

Object ID

1.3.6.1.4.1.674.10892.1.300.50.1.13

96

Chassis Information Group

Name

systemBIOSCharacteristicsExt1

Description

Defines additional characteristics of the system basic input/output
system (BIOS). This attribute is a bit field where a bit has the
meaning defined below when set to 1 (one).
Bit Position Meaning if Set
-------------- -----------------Bit 0ACPI supported
Bit 1USB Legacy is supported
Bit 2AGP is supported
Bit 3I2O boot is supported
Bit 4LS-120 boot is supported
Bit 5ATAPI ZIP Drive boot is supported
Bit 61394 boot is supported
Bit 7Smart Battery supported

Syntax

DellUnsigned8BitRange

Access

Read-only

System BIOS Characteristics Ext 2
Name

systemBIOSCharacteristicsExt2

Object ID

1.3.6.1.4.1.674.10892.1.300.50.1.14

Description

Defines additional characteristics of the system BIOS.
This attribute is a bit field where a bit has the meaning defined
below when set to 1 (one).
Bit Position Meaning if Set
--------------- -------------------Bit 0BIOS Boot Specification supported
Bit 1Function key-initiated Network Service boot supported
Bit 2Targeted Content Distribution supported
Bit 3-7Reserved

Syntax

DellUnsigned8BitRange

Access

Read-only

Chassis Information Group

97

Firmware Table
Name

firmwareTable

Object ID

1.3.6.1.4.1.674.10892.1.300.60

Description

Defines the Firmware Table.

Syntax

SEQUENCE OF FirmwareTableEntry

Access

Not accessible

Firmware Table Entry
Name

firmwareTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.300.60.1

Description

Defines the Firmware Table entry.

Syntax

FirmwareTableEntry

Access

Not accessible

Index

firmwarechassisIndex, firmwareIndex

Firmware Chassis Index
Name

firmwarechassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.300.60.1.1

Description

Defines the index (one-based) of this chassis.

Syntax

DellObjectRange

Access

Read-only

Firmware Index
Name

firmwareIndex

Object ID

1.3.6.1.4.1.674.10892.1.300.60.1.2

Description

Defines the index (one-based) of the firmware in this chassis.

Syntax

DellObjectRange

Access

Read-only

98

Chassis Information Group

Firmware State Capabilities
Name

firmwareStateCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.300.60.1.3

Description

Defines the capabilities of the firmware states.

Syntax

DellStateCapabilities

Access

Read-only

Firmware State Capabilities
Name

firmwareStateCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.300.60.1.4

Description

Defines the state of the firmware and allows for the setting of the
firmware.

Syntax

DellStateSettings

Access

Read-write

Firmware Status
Name

firmwareStatus

Object ID

1.3.6.1.4.1.674.10892.1.300.60.1.5

Description

Defines the status of the firmware.

Syntax

DellStateSettings

Access

Read-only

Firmware Size
Name

firmwareSize

Object ID

1.3.6.1.4.1.674.10892.1.300.60.1.6

Description

Defines the image size of the firmware in KB. A zero (0) indicates
that the size is unknown.

Syntax

DellUnsigned16BitRange

Access

Read-only

Chassis Information Group

99

Firmware Type
Name

firmwareType

Object ID

1.3.6.1.4.1.674.10892.1.300.60.1.7

Description

Defines the type of the firmware.

Syntax

DellFirmwareType

Access

Read-only

Firmware Type Name
Name

firmwareTypeName

Object ID

1.3.6.1.4.1.674.10892.1.300.60.1.8

Description

Defines the name of firmware type.

Syntax

DellString

Access

Read-only

Firmware Update Capabilities
Name

firmwareUpdateCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.300.60.1.9

Description

Defines the bitmap of supported methods for firmware update.

Syntax

DellUnsigned16BitRange

Access

Read-only

Firmware Date Name
Name

firmwareDateName

Object ID

1.3.6.1.4.1.674.10892.1.300.60.1.10

Description

Defines the date of the firmware.

Syntax

DellDateName

Access

Read-only

100

Chassis Information Group

Firmware Version Name
Name

firmwareVersionName

Object ID

1.3.6.1.4.1.674.10892.1.300.60.1.11

Description

Defines the version name of the firmware.

Syntax

DellString

Access

Read-only

Intrusion Table
The following objects and attributes describe the different forms of chassis
intrusion, a situation that occurs when the cover of a computer is removed.
Name

intrusionTable

Object ID

1.3.6.1.4.1.674.10892.1.300.70

Description

Defines the Intrusion Table.

Syntax

SEQUENCE OF IntrusionTableEntry

Access

Not accessible

Intrusion Table Entry
Name

intrusionTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.300.70.1

Description

Defines the Intrusion Table entry.

Syntax

IntrusionTableEntry

Access

Not accessible

Index

intrusionchassisIndex, intrusionIndex

Intrusion Chassis Index
Name

intrusionchassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.300.70.1.1

Description

Defines the index (one-based) of this chassis.

Syntax

DellObjectRange

Access

Read-only
Chassis Information Group

101

Intrusion Index
Name

intrusionIndex

Object ID

1.3.6.1.4.1.674.10892.1.300.70.1.2

Description

Defines the index of the intrusion objects in this subgroup.

Syntax

DellObjectRange

Access

Read-only

Intrusion State Capabilities
Name

intrusionStateCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.300.70.1.3

Description

Defines the capabilities of the intrusion object.

Syntax

DellStateCapabilities

Access

Read-only

Intrusion State Settings
Name

intrusionStateSettings

Object ID

1.3.6.1.4.1.674.10892.1.300.70.1.4

Description

Defines the settings of the intrusion object.

Syntax

DellStateSettings

Access

Read-write

Intrusion Status
Name

intrusionStatus

Object ID

1.3.6.1.4.1.674.10892.1.300.70.1.5

Description

Defines the status of the intrusion object.

Syntax

DellStatus

Access

Read-only

102

Chassis Information Group

Intrusion Reading
Name

intrusionReading

Object ID

1.3.6.1.4.1.674.10892.1.300.70.1.6

Description

Defines the reading of the intrusion object.

Syntax

DellIntrusionReading

Access

Read-only

Intrusion Type
Name

intrusionType

Object ID

1.3.6.1.4.1.674.10892.1.300.70.1.7

Description

Defines the type of the intrusion object.

Syntax

DellIntrusionType

Access

Read-only

Intrusion Location Name
Name

intrusionLocationName

Object ID

1.3.6.1.4.1.674.10892.1.300.70.1.8

Description

Defines the location name of the intrusion object in this subgroup.

Syntax

DellString

Access

Read-only

Baseboard Table
This table lists objects that define the baseboard of a system.
Name

baseBoardTable

Object ID

1.3.6.1.4.1.674.10892.1.300.80

Description

Defines the Baseboard Table.

Syntax

SEQUENCE OF BaseBoardTableEntry

Access

Not accessible

Chassis Information Group

103

Baseboard Table Entry
Name

baseBoardTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.300.80.1

Description

Defines the Baseboard Table entry.

Syntax

BaseBoardTableEntry

Access

Not accessible

Index

baseBoardChassisIndex, baseBoardIndex

Baseboard Chassis Index
Name

baseBoardChassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.300.80.1.1

Description

Defines the index (one-based) of the associated chassis.

Syntax

DellObjectRange

Access

Read-only

Baseboard Index
Name

baseBoardIndex

Object ID

1.3.6.1.4.1.674.10892.1.300.80.1.2

Description

Defines the index (one-based) of the base board.

Syntax

DellObjectRange

Access

Read-only

Baseboard State Capabilities
Name

baseBoardStateCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.300.80.1.3

Description

Defines the state capabilities of the baseboard.

Syntax

DellStateCapabilities

Access

Read-only

104

Chassis Information Group

Baseboard State Settings
Name

baseBoardStateSettings

Object ID

1.3.6.1.4.1.674.10892.1.300.80.1.4

Description

Defines the state settings of the baseboard.

Syntax

DellStateSettings

Access

Read-write

Baseboard Status
Name

baseBoardStatus

Object ID

1.3.6.1.4.1.674.10892.1.300.80.1.5

Description

Defines the status of the baseboard.

Syntax

DellStatus

Access

Read-only

Baseboard Feature Flags
Name

baseBoardFeatureFlags

Object ID

1.3.6.1.4.1.674.10892.1.300.80.1.6

Description

Defines the features of the baseboard.

Syntax

DellBaseBoardFeatureFlags

Access

Read-only

Baseboard Type
Name

baseBoardType

Object ID

1.3.6.1.4.1.674.10892.1.300.80.1.7

Description

Defines the type of the baseboard.

Syntax

DellBaseBoardType

Access

Read-only

Chassis Information Group

105

Baseboard Type Name
Name

baseBoardTypeName

Object ID

1.3.6.1.4.1.674.10892.1.300.80.1.8

Description

Defines the name of the type of baseboard.

Syntax

DellString

Access

Read-only

Baseboard Location Name
Name

baseBoardLocationName

Object ID

1.3.6.1.4.1.674.10892.1.300.80.1.9

Description

Defines the location name of the baseboard.

Syntax

DellString

Access

Read-only

Baseboard Manufacturer Name
Name

baseBoardManufacturerName

Object ID

1.3.6.1.4.1.674.10892.1.300.80.1.10

Description

Defines the baseboard manufacturer’s name.

Syntax

DellString

Access

Read-only

Baseboard Product Name
Name

baseBoardProductName

Object ID

1.3.6.1.4.1.674.10892.1.300.80.1.11

Description

Defines the baseboard product’s name.

Syntax

DellString

Access

Read-only

106

Chassis Information Group

Baseboard Version Name
Name

baseBoardVersionName

Object ID

1.3.6.1.4.1.674.10892.1.300.80.1.12

Description

Defines the baseboard version name.

Syntax

DellString

Access

Read-only

Baseboard Service Tag Name
Name

baseBoardServiceTagName

Object ID

1.3.6.1.4.1.674.10892.1.300.80.1.13

Description

Defines the baseboard service tag name.

Syntax

DellString

Access

Read-only

Baseboard Piece Part ID (PPID) Name
Name

baseBoardPiecePartIDName

Object ID

1.3.6.1.4.1.674.10892.1.300.80.1.14

Description

Defines the baseboard PPID.

Syntax

DellString

Access

Read-only

Baseboard Asset Tag Name
Name

baseBoardAssetTagName

Object ID

1.3.6.1.4.1.674.10892.1.300.80.1.15

Description

Defines the baseboard asset tag name.

Syntax

DellString

Access

Read-only

Chassis Information Group

107

Baseboard Express Service Code Name
Name

baseBoardExpressServiceCodeName

Object ID

1.3.6.1.4.1.674.10892.1.300.80.1.16

Description

Defines the express service code of the baseboard.

Syntax

DellString

Access

Read-only

Chassis Information Group Variable Values
This section includes definitions for server administrator-specific variable
values used in this section.
Table 6-1. Log Format
Variable Name: DellLogFormat
Data Type: Integer
Possible Data Values

Meaning of Data Value

raw(1)

The log is in the format received from the
firmware.

ascii(2)

The log is in ASCII format.

uniCode(3)

The log is in Unicode format.

Table 6-2. Chassis Type
Variable Name: DellChassisType
Data Type: Integer
Possible Data Values

Meaning of Data Value

other(1)

The chassis type is not one of the following:

unknown(2)

The chassis type is unknown.

desktop(3)

The chassis type is a desktop.

lowProfileDesktop(4)

The chassis type is a low-profile desktop.

pizzaBox(5)

The chassis type is a pizza box.

miniTower(6)

The chassis type is a minitower.

108

Chassis Information Group

Table 6-2. Chassis Type (continued)
Variable Name: DellChassisType
Data Type: Integer
Possible Data Values

Meaning of Data Value

tower(7)

The chassis type is a tower.

portable(8)

The chassis type is a portable.

lapTop(9)

The chassis type is a laptop.

noteBook(10)

The chassis type is a notebook.

handHeld(11)

The chassis type is a handheld.

dockingStation(12)

The chassis type is a docking station.

allInOne(13)

The chassis type is an all-in-one.

subNoteBook(14)

The chassis type is a subnotebook.

spaceSaving(15)

The chassis type is a spacesaver.

lunchBox(16)

The chassis type is a lunch box.

mainSystemChassis(17)

The chassis type is the main system chassis.

expansionChassis(18)

The chassis type is an expansion chassis.

subChassis(19)

The chassis type is a subchassis.

busExpansionChassis(20)

The chassis type is a bus-expansion chassis.

peripheralChassis(21)

The chassis type is a peripheral chassis.

raidChassis(22)

The chassis type is a disk RAID chassis.

rackMountChassis(23)

The chassis type is a rack-mounted chassis.

sealedCasePC(24)

The chassis type is a sealed-case chassis.

multiSystemChassis(25)

The chassis type is a multisystem chassis.

Chassis Information Group

109

Table 6-3. Connection Status
Variable Name: DellConnectionStatus
Data Type: Integer
Possible Data Values

Meaning of Data Value

unknown(2)

The status of the chassis connection is
unknown.

ok(3)

The status of the chassis connection is OK.

failure(4)

The status of the chassis connection is
failure.

Table 6-4. Fan Control Capabilities
Variable Name: DellFanControlCapabilities
Data Type: Integer
Possible Data Values

Meaning of Data Value

unknown(1)

The fan’s capabilities are unknown.

lowSpeedCapable(2)

The fan can be set to low speed.

highSpeedCapable(4)

The fan can be set to high speed.

lowOrhighSpeedCapable(6)

The fan can be set to low or high speed.

Table 6-5. Front-Panel LED Control Capabilities
Variable Name: DellLEDControlCapabilities
Data Type: Integer
Possible Data Values

Meaning of Data Value

unknown(1)

The LED control capabilities are unknown.

alertOnErrorCapable(2)

The LED control can be set to alert on an
error condition.

alertOnWarningAndErrorCap The LED control can be set to alert on an
able(4)
error and a warning condition.
alertOnWarningOrErrorCapa The LED control can be set to alert on an
ble(6)
error or a warning condition.

110

Chassis Information Group

Table 6-6. Front-Panel LED Control Settings
Variable Name: DellLEDControlSettings
Data Type: Integer
Possible Data Values

Meaning of Data Value

unknown(1)

The LED control setting is unknown.

alertOnError(2)

The LED control is set to alert on an error
condition.

alertOnWarningAndError(4) The LED control is set to alert on an error or
a warning condition.
Table 6-7. Hard-Drive Fault LED Control Capabilities
Variable Name: DellHDFaultLEDControlCapabilities
Data Type: Integer
Possible Data Values

Meaning of Data Value

none(0)

The hard drive has no fault LED
capabilities.

unknownCapabilities(1)

The hard-drive fault LED capabilities are
unknown.

enableCapable(2)

The hard-drive fault LED can be disabled
(offline, a binary 0 value) or enabled (online,
a binary 1 value).

notReadyCapable(4)

The hard-drive fault LED can indicate not
ready.

resetCapable(8)

The hard-drive fault LED can be reset.

Chassis Information Group

111

Table 6-8. Hard-Drive Fault LED Control Settings
Variable Name: DellHDFaultLEDControlSettings
Data Type: Integer
Possible Data Values

Meaning of Data Value

none(0)

The LEDs do not have any fault settings
capabilities.

unknown(1)

The hard-drive fault LEDs’ state is
unknown.

enabled(2)

The hard-drive fault LEDs’ state is disabled
(offline, a binary 0 value) or enabled (online,
a binary 1 value).

notReady(4)

The hard-drive fault LEDs’ state is not ready.

reset(8)

The hard-drive fault LEDs have been reset.

resetAndEnable(10)

The hard-drive fault LEDs have been reset
and enabled.

Table 6-9. Chassis Identification Control Capabilities
Variable Name: DellChassisIdentifyControlCapabilities
Data Type: Integer
Possible Data Values

Meaning of Data Value

none(0)

The LEDs do not have any chassis
identification capabilities.

unknownCapabilities(1)

The chassis identification control’s
capabilities are unknown.

enableCapable(2)

The chassis identification controls can be
disabled (offline, a binary 0 value) or
enabled (online, a binary 1 value).

notReadyCapable(4)

The chassis identification control’s
capabilities are not ready.

identifyCapable(8)

The chassis identification control’s LEDs
can be made to identify the chassis.

112

Chassis Information Group

Table 6-9. Chassis Identification Control Capabilities (continued)
Variable Name: DellChassisIdentifyControlCapabilities
Data Type: Integer
Possible Data Values

Meaning of Data Value

NOTE: Chassis identification capabilities allow system administrators to set front
panel light-emitting diodes (LEDs) to blink when the chassis has malfunctioning
components. When enabled, the blinking lights help administrators locate the
problem chassis.

Table 6-10.

Chassis Identification Control Settings

Variable Name: DellChassisIdentifyControlSettings
Data Type: Integer
Possible Data Values

Meaning of Data Value

unknown(1)

The chassis identification control’s state is
unknown.

enabled(2)

The chassis identification control’s state is
disabled (offline, a binary 0 value) or
enabled (online, a binary 1 value).

notReady(4)

The chassis identification control’s state
is not ready.

identifyChassis(8)

The chassis identification control’s
LEDs may be returned to (normal) 0,
or (identify chassis) 1.

identifyChassisAndEnable The chassis identification control’s
(10)
LEDs may be returned to normal

(a binary 0 value), or identify chassis
and enabled (a binary 1 value).

Chassis Information Group

113

Table 6-11. Host Control Capabilities
Variable Name: DellHostControlCapabilities

NOTE: An operator can manually enable these actions using SNMP.
Data Type: Integer
Possible Data Values

Meaning of Data Value

manualRebootCapable(1)

The operator can reboot capable host.

manualPowerOFFCapable(2)

The operator can power off capable host.

manualPowerCycleCapable(4) The operator can power-cycle capable
host.
manualAllExceptOperating The operator can reboot and power off
SystemShutdownCapable(7) capable host.
manualOperatingSystemShut The operator can shut down the
downCapable(8)
operating-system–shutdown capable host.
manualFullyCapable(15)

The operator can reboot, power on and off
the power-cycle capable host, and shut
down the operating-system–shutdown
capable host.

manualRebootWithOSShutdow The operator can reboot with operating
nCapable(16)
system shutdown.
manualRebootWithoutOSShut The operator can reboot without
downCapable(32)
operating system shutdown.
manualPowerOffWithOSShutd The operator can power off with operating
ownCapable(64)
system shutdown.
manualPowerOffWithoutOSSh The operator can power off without
utdownCapable(128)
operating system shutdown.
manualPowerCycleWithOSShu The operator can power cycle with
tdownCapable(256)
operating system shutdown.
manualPowerCycleWithoutOS The operator can power cycle without
ShutdownCapable(512)
operating system shutdown.

114

Chassis Information Group

Table 6-12.

Host Control Settings

Variable Name: DellHostControlSettings

NOTE: An operator can manually cause these actions using SNMP.
Data Type: Integer
Possible Data Values

Meaning of Data Value

manualReboot(1)

The operator can reboot the host.

manualPowerOFF(2)

The operator can power off the host.

manualPowerCycle(4)

Power cycle the host.

manualOperatingSystemShutdown(8) The operator can shut down the
operating system on the host.
manualOperatingSystemShutdownThe The operator can shut down the
nPowerCycle(12)
operating system on the host then
power cycle machine.
Table 6-13.

Watchdog Control Capabilities

Variable Name: DellWatchDogControlCapabilities

NOTE: When the system determines that the operating system is not responding, it
automatically performs the selected action without operator intervention.
Data Type: Integer
Possible Data Values

Meaning of Data Value

automaticRebootCapable(1)

Watchdog controls can be set to
reboot capable host.

automaticPowerCycleCapable(2)

Watchdog controls can be set to
power cycleable capable host.

automaticNotificationCapable(4) Watchdog controls can be set to
notify capable host.
automaticWatchDogTimerCapable(8) Watchdog controls can be set to
function automatically.
automaticPowerOffCapable(16)

Watchdog controls can be set to
automatically power off host.

Chassis Information Group

115

Table 6-13.

Watchdog Control Capabilities (continued)

Variable Name: DellWatchDogControlCapabilities

NOTE: When the system determines that the operating system is not responding, it
automatically performs the selected action without operator intervention.
Data Type: Integer
Possible Data Values

Meaning of Data Value

automaticAllExceptNotificationCap Watchdog controls can be set to
able(27)
automatically perform all functions
except notification capable.
automaticFullyCapable(31)

Table 6-14.

Watchdog controls can be set to
automatically perform all functions.

Watchdog Control Settings

Variable Name: DellWatchControlSettings

NOTE: The watchdog timer is the mechanism used by a chassis to determine if the
operating system has stopped responding.
Data Type: Integer
Possible Data Values

Meaning of Data Value

automaticRebootEnabled(1)

Automatic reboot is enabled for this
host.

automaticPowerCycleEnabled(2)

Automatic power cycleable is enabled
for this host.

automaticNotificationEnabled(4) Automatic notification is enabled for
this host.
automaticPowerOffEnabled(8)

116

Chassis Information Group

Automatic power off is enabled for
this host.

Table 6-15.

Watchdog Timer Capabilities

Variable Name: DellWatchDogTimerCapabilities
Data Type: Integer
Possible Data Values

Meaning of Data Value

type1Capable(1)

Watchdog timer can time in intervals from
20–480 seconds.

type2Capable(2)

Watchdog timer can time in 30-, 60-, 120-, and
480-second intervals.

type3Capable(4)

Watchdog timer can time in 60-second intervals.

Table 6-16.

Power Button Control Capabilities

Variable Name: DellPowerButtonControlCapabilities
Data Type: Integer
Possible Data Values

Meaning of Data Value

none(0)

The power button has no capabilities.

unknownCapabilities(1) The power button capabilities are unknown.
enableCapable(2)

Table 6-17.

The power button can be enabled (online) or
disabled (offline).

Power Button Control Settings

Variable Name: DellPowerButtonControlSettings
Data Type: Integer
Possible Data Values

Meaning of Data Value

none(0)

The power button has no settings capabilities.

unknown(1)

The power button settings are unknown.

enabled(2)

The power button state is enabled.

disabled(4)

The power button state is disabled.

Chassis Information Group

117

Table 6-18.

NMI Button Control Capabilities

Variable Name: DellNMIButtonControlCapabilities
Data Type: Integer
Possible Data Values

Meaning of Data Value

none(0)

The NMI button has no capabilities.

unknownCapabilities(1) The NMI button capabilities are unknown.
The NMI button can be enabled (online) or
disabled (offline).

enableCapable(2)

Table 6-19.

System Properties

Variable Name: DellSystemProperties

NOTE: These values are bit masks, so combination values are possible.
Data Type: Integer
Possible Data Values

Meaning of Data Value

none(0)

No properties.

energySmart(1)

The system is an Energy Smart System.

Table 6-20.

NMI Button Control Settings

Variable Name: DellNMIButtonControlSettings
Data Type: Integer

118

Possible Data Values

Meaning of Data Value

none(0)

The NMI button has no settings capabilities.

unknown(1)

The NMI button settings are unknown.

enabled(2)

The NMI button state is enabled.

disabled(4)

The NMI button state is disabled.

Chassis Information Group

Table 6-21.

Baseboard Type

Variable Name: DellBaseBoardType
Data Type: Integer
Possible Data Values

Meaning of Data Value

unknown(1)

The baseboard type is unknown.

other(2)

The baseboard type is not one of the
following types.

serverBlade(3)

The baseboard type is a server blade.

connectivitySwitch(4)

The baseboard type is a connectivity switch.

systemManagementModule(5) The baseboard type is a system management
module.
processorModule(6)

The baseboard type is a processor module.

ioModule(7)

The baseboard type is an I/O module.

memoryModule(8)

The baseboard type is a memory module

daughterBoard(9)

The baseboard type is a daughter board.

motherboard(10)

The baseboard type is a mother board.

processorMemoryModule(11) The baseboard type is a processor or memory
module
processorIOModule(12)

The baseboard type is a processor or
I/O module

interconnectBoard(13)

The baseboard type is an interconnect board.

Table 6-22.

Chassis System Class

Variable Name: DellChassisSystemClass
Data Type: Integer
Possible Data Values

Meaning of Data Value

other(1)

The chassis system class is not one of the following:

unknown(2)

The chassis system class is unknown.

workstationClass(3) The chassis system class is a workstation.
serverClass(4)

The chassis system class is a server.

Chassis Information Group

119

Table 6-22. Chassis System Class (continued)
Variable Name: DellChassisSystemClass
Data Type: Integer
Possible Data Values

Meaning of Data Value

desktopClass(5)

The chassis system class is a desktop.

portableClass(6)

The chassis system class is a portable.

netPCClass(7)

The chassis system class is a Net PC.

storageClass(8)

The chassis system class is storage.

Table 6-23. Firmware Type
Variable Name: DellFirmwareType
Data Type: Integer
Possible Data Values

Meaning of Data Value

other(1)

The firmware type is other than
following values.

unknown(2)

The firmware type is unknown.

systemBIOS(3)

The firmware type is System BIOS

embeddedSystemManagementContro The firmware type is Embedded
ller(4)
System Management Controller.
powerSupplyParallelingBoard(5) The firmware type is Power Supply
Paralleling Board.
systemBackPlane(6)

The firmware type is System
(Primary) Backplane.

powerVault2XXSKernel(7)

The firmware type is Dell
PowerVault 2XXS Kernel.

powerVault2XXSApplication(8)

The firmware type is PowerVault
2XXS Application.

frontPanel(9)

The firmware type is Front Panel
Controller.

baseboardManagementController
(10)

The firmware type is Baseboard
Management Controller.

120

Chassis Information Group

Table 6-23.

Firmware Type (continued)

Variable Name: DellFirmwareType
Data Type: Integer
Possible Data Values

Meaning of Data Value

hotPlugPCI(11)

The firmware type is Hot Plug
Peripheral Component Interconnect
(PCI) Controller.

sensorData(12)

The firmware type is Sensor Data
Records.

peripheralBay(13)

The firmware type is Peripheral Bay
Backplane.

secondaryBackPlane(14)

The firmware type is Secondary
Backplane for ESM 2 systems.

secondaryBackPlaneESM3And4(15)

The firmware type is Secondary
Backplane for ESM 3 and 4 systems.

rac(16)

The firmware type is Remote
Access Controller.

iDRAC(17)

The firmware type is Integrated
Dell Remote Access Controller.

unifiedServerConfigurator(19)

The firmware type is Unified Server
Configurator.

lifecycleController(20)

The firmware type is Lifecycle
Controller.

Table 6-24.

Baseboard Feature Flags

Variable Name: DellBaseBoardFeatureFlags
Data Type: Integer
Possible Data Values

Meaning of Data Value

NOTE: These values are bit fields, so combination values are possible.
no features(0)

This baseboard has no feature flags.

boardIsHostingBoard(1)

This baseboard is a hosting board.

Chassis Information Group

121

Table 6-24. Baseboard Feature Flags
Variable Name: DellBaseBoardFeatureFlags
Data Type: Integer
Possible Data Values

Meaning of Data Value

boardRequiresDaughterBoard This baseboard requires at least one
(2)
daughter board or auxiliary card.
boardIsRemovable(4)

This baseboard is removable.

boardIsReplaceable(8)

This baseboard is replaceable.

boardIsHotSwappable(16)

This baseboard is hot swappable.

122

Chassis Information Group

Operating System Group

7

The Operating System Group provides status and identifying information
about a system’s operating system. Identifying information includes the
name, version, service pack, and patch level of the installed operating system.

Operating System Group Table
The following management information base (MIB) tables define the objects
in the Operating System Group:
•

"Operating System Table" on page 123

•

"Operating System Memory Table" on page 125

Operating System Table
The following object sets up the Operating System Table.
Name

operatingSystemTable

Object ID

1.3.6.1.4.1.674.10892.1.400.10

Description

Defines the Operating System Table.

Syntax

SEQUENCE OF OperatingSystemTableEntry

Access

Not accessible

Operating System Table Entry
Name

operatingSystemTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.400.10.1

Description

Defines the Operating System Table entry.

Syntax

OperatingSystemTableEntry

Access

Not accessible

Index

operatingSystemchassisIndex

Operating System Group

123

Operating System Chassis Index
Name

operatingSystemchassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.400.10.1.1

Description

Defines the index (one-based) of the associated chassis.

Syntax

DellObjectRange

Access

Read-only

Operating System State Capabilities
Name

operatingSystemStateCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.400.10.1.2

Description

Defines the capabilities of the operating system.

Syntax

DellStateCapabilities

Access

Read-only

Operating System State Settings
Name

operatingSystemStateSettings

Object ID

1.3.6.1.4.1.674.10892.1.400.10.1.3

Description

Defines the state of the operating system.

Syntax

DellStateSettings

Access

Read-write

Operating System Status
Name

operatingSystemStatus

Object ID

1.3.6.1.4.1.674.10892.1.400.10.1.4

Description

Defines the status of the operating system.

Syntax

DellStatus

Access

Read-only

124

Operating System Group

Operating System Is Primary
Name

operatingSystemIsPrimary

Object ID

1.3.6.1.4.1.674.10892.1.400.10.1.5

Description

Specifies whether this operating system is the primary operating
system.

Syntax

DellBoolean

Access

Read-only

Operating System Name
Name

operatingSystemOperatingSystemName

Object ID

1.3.6.1.4.1.674.10892.1.400.10.1.6

Description

Defines the name of the operating system running on the system.

Syntax

DisplayString (SIZE (0..255))

Access

Read-only

Operating System Version Name
Name

operatingSystemOperatingSystemVersionName

Object ID

1.3.6.1.4.1.674.10892.1.400.10.1.7

Description

Defines the version of the operating system running on the
system.

Syntax

DisplayString (SIZE (0..255))

Access

Read-only

Operating System Memory Table
Name

operatingSystemMemoryTable

Object ID

1.3.6.1.4.1.674.10892.1.400.20

Description

Defines the Operating System Memory Table.

Syntax

SEQUENCE OF OperatingSystemMemoryTableEntry

Access

Not accessible

Operating System Group

125

Operating System Memory Table Entry
Name

operatingSystemTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.400.20.1

Description

Defines the Operating System Memory Table entry.

Syntax

OperatingSystemMemoryTableEntry

Access

Not accessible

Index

operatingSystemMemorychassisIndex

Operating System Memory Chassis Index
Name

operatingSystemMemorychassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.400.20.1.1

Description

Defines the index (one-based) of this chassis.

Syntax

DellObjectRange

Access

Read-only

Operating System Memory State Capabilities
Name

operatingSystemMemoryStateCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.400.20.1.2

Description

Defines the capabilities of the operating system memory.

Syntax

DellStateCapabilities

Access

Read-only

Operating System Memory State Settings
Name

operatingSystemMemoryStateSettings

Object ID

1.3.6.1.4.1.674.10892.1.400.20.1.3

Description

Defines the state and allows the setting of the operating system
memory.

Syntax

DellStateSettings

Access

Read-write

126

Operating System Group

Operating System Memory Status
Name

operatingSystemMemoryStatus

Object ID

1.3.6.1.4.1.674.10892.1.400.20.1.4

Description

Defines the status of the operating system memory.

Syntax

DellStatus

Access

Read-only

Operating System Memory Total Physical Size
Name

operatingSystemMemoryTotalPhysicalSize

Object ID

1.3.6.1.4.1.674.10892.1.400.20.1.5

Description

Defines the total physical memory size in kilobytes.

Syntax

DellUnsigned32BitRange

Access

Read-only

Operating System Memory Available Physical Size
Name

operatingSystemMemoryAvailablePhysicalSize

Object ID

1.3.6.1.4.1.674.10892.1.400.20.1.6

Description

Defines the available physical memory size in kilobytes.

Syntax

DellUnsigned32BitRange

Access

Read-only

Operating System Memory Total Page File Size
Name

operatingSystemMemoryTotalPageFileSize

Object ID

1.3.6.1.4.1.674.10892.1.400.20.1.7

Description

Defines the total page file memory size in kilobytes.

Syntax

DellUnsigned32BitRange

Access

Read-only

Operating System Group

127

Operating System Memory Available Page File Size
Name

operatingSystemMemoryAvailablePageFileSize

Object ID

1.3.6.1.4.1.674.10892.1.400.20.1.8

Description

Defines the available page file memory size in kilobytes.

Syntax

DellUnsigned32BitRange

Access

Read-only

Operating System Memory Total Virtual Size
Name

operatingSystemMemoryTotalVirtualSize

Object ID

1.3.6.1.4.1.674.10892.1.400.20.1.9

Description

Defines the total virtual memory size in kilobytes.

Syntax

DellUnsigned32BitRange

Access

Read-only

Operating System Memory Available Virtual Size
Name

operatingSystemMemoryAvailableVirtualSize

Object ID

1.3.6.1.4.1.674.10892.1.400.20.1.10

Description

Defines the available virtual memory size in kilobytes.

Syntax

DellUnsigned32BitRange

Access

Read-only

128

Operating System Group

Operating System Group

129

130

Operating System Group

System Resource Group

8

The Management Information Base (MIB) variables presented in this section
enable you to track various attributes of your system resources. This section
includes "System Resource Group Tables" on page 131 that track variables
such as the owner, ports, system memory, interrupts, and direct memory
access.

System Resource Group Tables
The following MIB tables define objects for the System Resource Group:
•

"System Resource Map Table" on page 131

•

"System Resource Owner Table" on page 133

•

"System Resource Input/Output (I/O) Port Table" on page 136

•

"System Resource Memory Table" on page 139

•

"System Resource Interrupt Table" on page 142

•

"System Resource Direct Memory Access (DMA) Table" on page 145

System Resource Map Table
Name

systemResourceMapTable

Object ID

1.3.6.1.4.1.674.10892.1.500.10

Description

Defines the System Resource Map Table.

Syntax

SEQUENCE OF SystemResourceMapTableEntry

Access

Not accessible

System Resource Group

131

System Resource Map Table Entry
Name

systemResourceMapTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.500.10.1

Description

Defines the System Resource Map Table entry.

Syntax

SystemResourceMapTableEntry

Access

Not accessible

Index

systemResourceMapchassisIndex, systemResourceMapIndex

System Resource Map Chassis Index
Name

systemResourceMapChassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.500.10.1.1

Description

Defines the index (one-based) of this chassis.

Syntax

DellObjectRange

Access

Read-only

System Resource Map Index
Name

systemResourceMapIndex

Object ID

1.3.6.1.4.1.674.10892.1.500.10.1.2

Description

Defines the index of system resource maps in this chassis.

Syntax

DellObjectRange

Access

Read-only

System Resource Map State Capabilities
Name

systemResourceMapStateCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.500.10.1.3

Description

Defines the capabilities of this system map.

Syntax

DellStateCapabilities

Access

Read-only

132

System Resource Group

System Resource Map State Settings
Name

systemResourceMapStateSettings

Object ID

1.3.6.1.4.1.674.10892.1.500.10.1.4

Description

Defines the state and allows the setting of this system map.

Syntax

DellStateSettings

Access

Read-write

System Resource Map Status
Name

systemResourceMapStatus

Object ID

1.3.6.1.4.1.674.10892.1.500.10.1.5

Description

Defines the status of this system map.

Syntax

DellStatus

Access

Read-only

System Resource Map Type
Name

systemResourceMapType

Object ID

1.3.6.1.4.1.674.10892.1.500.10.1.6

Description

Defines the type of this system map.

Syntax

DellSystemResourceMapType (See Table 8-1)

Access

Read-only

System Resource Owner Table
Name

systemResourceOwnerTable

Object ID

1.3.6.1.4.1.674.10892.1.500.20

Description

Defines the System Resource Owner Table.

Syntax

SEQUENCE OF SystemResourceOwnerTableEntry

Access

Not accessible

System Resource Group

133

System Resource Owner Table Entry
Name

systemResourceOwnerTable

Object ID

1.3.6.1.4.1.674.10892.1.500.20.1

Description

Defines the System Resource Owner Table entry. Variables in
this group reference the System Resource Map index.

Syntax

SystemResourceOwnerTableEntry

Access

Not accessible

Index

systemResourceOwnerchassisIndex,
systemResourceOwnerIndex

System Resource Owner Chassis Index
Name

systemResourceOwnerchassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.500.20.1.1

Description

Defines the index (one-based) of this chassis.

Syntax

DellObjectRange

Access

Read-only

System Resource Owner Index
Name

systemResourceOwnerIndex

Object ID

1.3.6.1.4.1.674.10892.1.500.20.1.2

Description

Defines the index of system resource owners for this chassis.

Syntax

DellObjectRange

Access

Read-only

System Resource Owner State Capabilities
Name

systemResourceOwnerStateCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.500.20.1.3

Description

Defines the capabilities of this system resource owner.

Syntax

DellStateCapabilities

Access

Read-only

134

System Resource Group

System Resource Owner State Settings
Name

systemResourceOwnerStateSettings

Object ID

1.3.6.1.4.1.674.10892.1.500.20.1.4

Description

Defines the state settings of this system resource owner.

Syntax

DellStateSettings

Access

Read-write

System Resource Owner Status
Name

systemResourceOwnerStatus

Object ID

1.3.6.1.4.1.674.10892.1.500.20.1.5

Description

Defines the status of this system resource owner.

Syntax

DellStatus

Access

Read-write

System Resource Owner Interface Type
Name

systemResourceOwnerInterfaceType

Object ID

1.3.6.1.4.1.674.10892.1.500.20.1.6

Description

Defines the interface type for this system resource owner.

Syntax

DellResourceOwnerInterfaceType (See Table 8-2)

Access

Read-only

System Resource Map Index Reference
Name

systemResourceMapIndexReference

Object ID

1.3.6.1.4.1.674.10892.1.500.20.1.7

Description

Defines the index to the associated system resource map in this
chassis.

Syntax

DellObjectRange

Access

Read-only

System Resource Group

135

System Resource Owner Description Name
Name

systemResourceOwnerDescriptionName

Object ID

1.3.6.1.4.1.674.10892.1.500.20.1.8

Description

Defines the description name of the system resource owner.

Syntax

DellString

Access

Read-only

System Resource Owner Interface Instance
Name

systemResourceOwnerInterfaceInstance

Object ID

1.3.6.1.4.1.674.10892.1.500.20.1.9

Description

Defines the associated system resource owner interface instance
in this chassis.

Syntax

DellObjectRange

Access

Read-only

System Resource Input/Output (I/O) Port Table
Name

systemResourceIOPortTable

Object ID

1.3.6.1.4.1.674.10892.1.500.30

Description

Defines the System Resource I/O Port Table.

Syntax

SEQUENCE OF SystemResourceIOPortTableEntry

Access

Not accessible

System Resource I/O Port Table Entry
Name

systemResourceIOPortTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.500.30.1

Description

Defines the System Resource I/O Port Table entry.

Syntax

SystemResourceIOPortTableEntry

Access

Not accessible

Index

systemResourceIOPortchassisIndex,
systemResourceIOPortIndex

136

System Resource Group

System Resource I/O Port Chassis Index
Name

systemResourceIOPortchassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.500.30.1.1

Description

Defines the index (one-based) of this chassis.

Syntax

DellObjectRange

Access

Read-only

System Resource I/O Port Index
Name

systemResourceIOPortIndex

Object ID

1.3.6.1.4.1.674.10892.1.500.30.1.2

Description

Defines the index (one-based) of the system resource I/O ports
in this chassis.

Syntax

DellObjectRange

Access

Read-only

System Resource I/O Port State Capabilities
Name

systemResourceIOPortStateCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.500.30.1.3

Description

Defines the capabilities of the system resource I/O port.

Syntax

DellStateCapabilities

Access

Read-only

System Resource I/O Port State Settings
Name

systemResourceIOPortStateSettings

Object ID

1.3.6.1.4.1.674.10892.1.500.30.1.4

Description

Defines the state and allows the setting of the system resource
I/O port.

Syntax

DellStateSettings

Access

Read-write

System Resource Group

137

System Resource I/O Port Status
Name

systemResourceIOPortStatus

Object ID

1.3.6.1.4.1.674.10892.1.500.30.1.5

Description

Defines the status of the system resource I/O port.

Syntax

DellStateSettings

Access

Read-only

System Resource I/O Port Owner Index Reference
Name

systemResourceIOPortOwnerIndexReference

Object ID

1.3.6.1.4.1.674.10892.1.500.30.1.6

Description

Defines the index to the associated system resource owner in this
chassis.

Syntax

DellObjectRange

Access

Read-only

System Resource I/O Port Share Disposition
Name

systemResourceIOPortShareDisposition

Object ID

1.3.6.1.4.1.674.10892.1.500.30.1.7

Description

Defines the share disposition of the system resource I/O port.

Syntax

DellResourceShareDisposition (See Table 8-3)

Access

Read-only

System Resource I/O Port Starting Address
Name

systemResourceIOPortStartingAddress

Object ID

1.3.6.1.4.1.674.10892.1.500.30.1.8

Description

Defines the 64 bits of the starting address of the system resource
I/O port.

Syntax

DellUnsigned64BitRange

Access

Read-only

138

System Resource Group

System Resource I/O Port Ending Address
Name

systemResourceIOPortEndingAddress

Object ID

1.3.6.1.4.1.674.10892.1.500.30.1.9

Description

Defines the 64 bits of the ending address of the system resource
I/O port.

Syntax

DellUnsigned64BitRange

Access

Read-only

System Resource Memory Table
Name

systemResourceMemoryTable

Object ID

1.3.6.1.4.1.674.10892.1.500.40

Description

Defines the System Resource Memory Table.

Syntax

SEQUENCE OF SystemResourceMemoryTableEntry

Access

Not accessible

System Resource Memory Table Entry
Name

systemResourceMemoryTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.500.40.1

Description

Defines the System Resource Memory Table entry.

Syntax

SystemResourceMemoryTableEntry

Access

Not accessible

Index

systemResourceMemorychassisIndex,
systemResourceMemoryIndex

System Resource Memory Chassis Index
Name

systemResourceMemorychassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.500.40.1.1

Description

Defines the index (one-based) of this chassis.

Syntax

DellObjectRange

Access

Read-only
System Resource Group

139

System Resource Memory Index
Name

systemResourceMemoryIndex

Object ID

1.3.6.1.4.1.674.10892.1.500.40.1.2

Description

Defines the index of system resource memory in this chassis.

Syntax

DellObjectRange

Access

Read-only

System Resource Memory State Capabilities
Name

systemResourceMemoryStateCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.500.40.1.3

Description

Defines the capabilities of this system resource memory.

Syntax

DellObjectRange

Access

Read-only

System Resource Memory State Settings
Name

systemResourceMemoryStateSettings

Object ID

1.3.6.1.4.1.674.10892.1.500.40.1.4

Description

Defines the state of this system resource memory.

Syntax

DellObjectRange

Access

Read-write

System Resource Memory Status
Name

systemResourceMemoryStatus

Object ID

1.3.6.1.4.1.674.10892.1.500.40.1.5

Description

Defines the status of this system resource memory.

Syntax

DellStatus

Access

Read-only

140

System Resource Group

System Resource Memory Owner Index Reference
Name

systemResourceMemoryOwnerIndexReference

Object ID

1.3.6.1.4.1.674.10892.1.500.40.1.6

Description

Defines the index to the associated system resource owner in this
chassis.

Syntax

DellObjectRange

Access

Read-only

System Resource Memory Share Disposition
Name

systemResourceMemoryShareDisposition

Object ID

1.3.6.1.4.1.674.10892.1.500.40.1.7

Description

Defines the share disposition of the system resource memory.

Syntax

DellResourceShareDisposition (See Table 8-3)

Access

Read-only

System Resource Memory Starting Address
Name

systemResourceMemoryStartingAddress

Object ID

1.3.6.1.4.1.674.10892.1.500.40.1.8

Description

Defines the 64 bits of the starting address of the system resource
memory.

Syntax

DellUnsigned64BitRange

Access

Read-only

System Resource Memory Ending Address
Name

systemResourceMemoryEndingAddress

Object ID

1.3.6.1.4.1.674.10892.1.500.40.1.9

Description

Defines the 64 bits of the ending address of the system resource
memory.

Syntax

DellUnsigned64BitRange

Access

Read-only
System Resource Group

141

System Resource Memory Flags
Name

systemResourceMemoryFlags

Object ID

1.3.6.1.4.1.674.10892.1.500.40.1.10

Description

Defines the permission flags for the system resource memory.

Syntax

DellResourceMemoryFlags (See Table 8-4)

Access

Read-only

System Resource Interrupt Table
Name

systemResourceInterruptTable

Object ID

1.3.6.1.4.1.674.10892.1.500.50

Description

Defines the System Resource Interrupt Table.

Syntax

SEQUENCE OF SystemResourceInterruptTableEntry

Access

Not accessible

System Resource Interrupt Table Entry
Name

systemResourceInterruptTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.500.50.1

Description

Defines the System Resource Interrupt Table entry.

Syntax

SystemResourceInterruptTableEntry

Access

Not accessible

Index

systemResourceInterruptchassisIndex,
systemResourceInterruptIndex

System Resource Interrupt Chassis Index
Name

systemResourceInterruptchassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.500.50.1.1

Description

Defines the index (one-based) of this chassis.

Syntax

DellObjectRange

Access

Not accessible

142

System Resource Group

System Resource Interrupt Index
Name

systemResourceInterruptIndex

Object ID

1.3.6.1.4.1.674.10892.1.500.50.1.2

Description

Defines the index (one-based) of this interrupt resource.

Syntax

DellObjectRange

Access

Read-only

System Resource Interrupt State Capabilities
Name

systemResourceInterruptStateCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.500.50.1.3

Description

Defines the capabilities of this system resource interrupt.

Syntax

DellStateCapabilities

Access

Read-only

System Resource Interrupt State Settings
Name

systemResourceInterruptStateSettings

Object ID

1.3.6.1.4.1.674.10892.1.500.50.1.4

Description

Defines the state of this system resource interrupt.

Syntax

DellStateSettings

Access

Read-write

System Resource Interrupt Status
Name

systemResourceInterruptStatus

Object ID

1.3.6.1.4.1.674.10892.1.500.50.1.5

Description

Defines the status of this system resource interrupt.

Syntax

DellStatus

Access

Read-only

System Resource Group

143

System Resource Interrupt Owner Index Reference
Name

systemResourceInterruptOwnerIndexReference

Object ID

1.3.6.1.4.1.674.10892.1.500.50.1.6

Description

Defines the index for the associated system resource owner in
this chassis.

Syntax

DellObjectRange

Access

Read-only

System Resource Interrupt Owner Share Disposition
Name

systemResourceInterruptShareDisposition

Object ID

1.3.6.1.4.1.674.10892.1.500.50.1.7

Description

Defines the share disposition of the system resource interrupt.

Syntax

DellResourceShareDisposition (See Table 8-3)

Access

Read-only

System Resource Interrupt Level
Name

systemResourceInterruptLevel

Object ID

1.3.6.1.4.1.674.10892.1.500.50.1.8

Description

Defines the interrupt request (IRQ) level of the system
resource interrupt.

Syntax

DellUnsigned32BitRange

Access

Read-only

System Resource Interrupt Type
Name

systemResourceInterruptType

Object ID

1.3.6.1.4.1.674.10892.1.500.50.1.9

Description

Defines the interrupt type of the system resource interrupt.

Syntax

DellResourceInterruptType (See Table 8-5)

Access

Read-only

144

System Resource Group

System Resource Interrupt Trigger
Name

systemResourceInterruptTrigger

Object ID

1.3.6.1.4.1.674.10892.1.500.50.1.10

Description

Defines the interrupt trigger of the system resource interrupt.

Syntax

DellResourceInterruptTrigger (See Table 8-6)

Access

Read-only

System Resource Direct Memory Access (DMA) Table
Name

systemResourceDMATable

Object ID

1.3.6.1.4.1.674.10892.1.500.60

Description

Defines the System Resource DMA Table.

Syntax

SEQUENCE OF SystemResourceDMATableEntry

Access

Not accessible

System Resource DMA Table Entry
Name

systemResourceDMATable

Object ID

1.3.6.1.4.1.674.10892.1.500.60.1

Description

Defines the System Resource DMA Table entry.

Syntax

SystemResourceDMATableEntry

Access

Not accessible

Index

systemResourceDMAchassisIndex, systemResourceDMAIndex

System Resource DMA Chassis Index
Name

systemResourceDMAchassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.500.60.1.1

Description

Defines the index (one-based) of this chassis.

Syntax

DellObjectRange

Access

Read-only

System Resource Group

145

System Resource DMA Index
Name

systemResourceDMAIndex

Object ID

1.3.6.1.4.1.674.10892.1.500.60.1.2

Description

Defines the index of system resource DMAs in this chassis.

Syntax

DellObjectRange

Access

Read-only

System Resource DMA State Capabilities
Name

systemResourceDMAStateCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.500.60.1.3

Description

Defines the capabilities of this system resource DMA.

Syntax

DellStateCapabilities

Access

Read-only

System Resource DMA State Settings
Name

systemResourceDMAStateSettings

Object ID

1.3.6.1.4.1.674.10892.1.500.60.1.4

Description

Defines the state and setting of this system resource DMA.

Syntax

DellStateSettings

Access

Read-write

System Resource DMA Status
Name

systemResourceDMAStatus

Object ID

1.3.6.1.4.1.674.10892.1.500.60.1.5

Description

Defines the status of this system resource DMA.

Syntax

DellStatus

Access

Read-only

146

System Resource Group

System Resource DMA Owner Index Reference
Name

systemResourceDMAOwnerIndexReference

Object ID

1.3.6.1.4.1.674.10892.1.500.60.1.6

Description

Defines the index to the associated system resource owner in this
chassis.

Syntax

DellObjectRange

Access

Read-only

System Resource DMA Share Disposition
Name

systemResourceDMAShareDisposition

Object ID

1.3.6.1.4.1.674.10892.1.500.60.1.7

Description

Defines the share disposition of the system resource DMA.

Syntax

DellResourceShareDisposition (See Table 8-3)

Access

Read-only

System Resource DMA Maximum Transfer Size
Name

systemResourceDMAMaximumTransferSize

Object ID

1.3.6.1.4.1.674.10892.1.500.60.1.8

Description

Defines the maximum size of a memory transfer in bytes for the
system resource DMA.

Syntax

DellUnsigned32BitRange

Access

Read-only

System Resource DMA Transfer Width
Name

systemResourceDMATransferWidth

Object ID

1.3.6.1.4.1.674.10892.1.500.60.1.9

Description

Defines the transfer width of the system resource DMA.

Syntax

DellResourceDMATransferWidth (See Table 8-8)

Access

Read-only

System Resource Group

147

System Resource DMA Bus Master
Name

systemResourceDMABusMaster

Object ID

1.3.6.1.4.1.674.10892.1.500.60.1.10

Description

Defines the bus mastering capabilities of the system resource DMA.

Syntax

DellResourceDMABusMaster (See Table 8-7)

Access

Read-only

System Resource Group Variable Values
This section includes definitions for server administrator-specific variable
values used in this section.
Table 8-1. System Resource Map Type
Variable Name: DellSystemResourceMapType
Data Type: Integer
Possible Data Values

Meaning of Data Value

other(1)

The system resource map type is not one of the
following:

unknown(2)

The system resource map type is unknown
(not known or not monitored).

typeOne(3)

The system resource map is type 1 (one).

Table 8-2. Resource Owner Interface Type
Variable Name: DellResourceOwnerInterfaceType
Data Type: Integer
Possible Data Values

Meaning of Data Value

typeIsOther(1)

The interface type is not one of the following:

typeIsUnknown(2)

The interface type is unknown.

typeIsInternal(3)

The interface type is internal.

typeIsISA(4)

The interface type is an Industry Standard
Architecture (ISA) bus.

148

System Resource Group

Table 8-2. Resource Owner Interface Type (continued)
Variable Name: DellResourceOwnerInterfaceType
Data Type: Integer
Possible Data Values

Meaning of Data Value

typeIsEISA(5)

The interface type is an Extended Industry Standard
Architecture (EISA) bus.

typeIsMCA(6)

The interface type is a microchannel architecture
(MCA) bus.

typeIsTurboChannel(7) The interface type is a turbo-channel bus.
Table 8-3. Resource Share Disposition
Variable Name: DellResourceShareDisposition
Data Type: Integer
Possible Data Values

Meaning of Data Value

shareIsOther(1)

The share disposition is not one of the following:

shareIsUnknown(2)

The share disposition is unknown (not known
or not monitored).

shareIsDeviceExclusive(3) The share disposition is device exclusive.
shareIsDriverExclusive(4) The share disposition is driver exclusive.
shareIsShared(5)

The share disposition is shared.

Table 8-4. Resource Memory Flags
Variable Name: DellResourceMemoryFlags
Data Type: Integer
Possible Data Values

Meaning of Data Value

memoryIsReadOnly(1)

The resource memory is read-only.

memoryIsWriteOnly(2)

The resource memory is write-only.

memoryIsPreFetchable(4)

The resource memory is prefetchable.

memoryIsCombinedWritable(8) The resource memory is read-write.
memoryIsF24(16)

The resource memory is F24.

System Resource Group

149

Table 8-5. Resource Interrupt Type
Variable Name: DellResourceInterruptType
Data Type: Integer
Possible Data Values

Meaning of Data Value

interruptIsLevelSensitive(1) The interrupt type is level sensitive.
The interrupt type is latched.

interruptIsLatched(2)

Table 8-6. Resource Interrupt Trigger
Variable Name: DellResourceInterruptTrigger
Data Type: Integer
Possible Data Values

Meaning of Data Value

interruptIsActiveWhenLow(1)

The interrupt trigger is active on a
low signal.

interruptIsActiveWhenHigh(2) The interrupt trigger is active on a
high signal.
Table 8-7. Resource DMA Bus Master
Variable Name: DellResourceDMABusMaster
Data Type: Integer
Possible Data Values

Meaning of Data Value

dmaIsOther(1)

The DMA bus master capability is not one of
the following:

dmaIsUnknown(2)

The DMA bus master capability is unknown.

dmaIsNotABusmaster(3)

The DMA does not have bus master capability.

150

System Resource Group

Table 8-8. Resource DMA Transfer Width
Variable Name: DellResourceDMATransferWidth
Data Type: Integer
Possible Data Values

Meaning of Data Value

dmaTransferWidthIsOther(1)

The DMA transfer width is not one of the
following:

dmaTransferWidthIsunknown(2) The DMA transfer width is unknown.
dmaTransferWidthIs8Bits(3)

The DMA transfer width is 8 bits.

dmaTransferWidthIs16Bits(4)

The DMA transfer width is 16 bits.

dmaTransferWidthIs32Bits(5)

The DMA transfer width is 32 bits.

dmaTransferWidthIs64Bits(6)

The DMA transfer width is 64 bits.

dmaTransferWidthIs128Bits(7) The DMA transfer width is 128 bits.

System Resource Group

151

152

System Resource Group

9

Power Group

The Power Group provides information about power units (a group of power
supplies in a system chassis), power supplies, and voltage and amperage probes.
NOTE: Power Management features are only available for PowerEdge systems
that have hot-swappable power supplies and not systems that have a fixed, nonredundant power supply installed.

Power Group Tables
The following management information base (MIB) tables define objects for
the Power Group:
•

"Power Unit Table" on page 153

•

"Power Supply Table" on page 156

•

"Voltage Probe Table" on page 160

•

"Amperage Probe Table" on page 165

•

"AC Power Switch Table" on page 171

•

"AC Power Cord Table" on page 173

•

"Battery Table" on page 176

•

"Power Usage Table" on page 178

•

"Power Profile Table" on page 184

Power Unit Table
Name

powerUnitTable

Object ID

1.3.6.1.4.1.674.10892.1.600.10

Description

Defines the Power Unit Table.

Syntax

PowerUnitTableEntry

Access

Not accessible

Power Group

153

Power Unit Table Entry
Name

powerUnitTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.600.10.1

Description

Defines the Power Unit Table entry.

Syntax

DellObjectRange

Access

Read-only

Index

powerUnitchassisIndex, powerUnitIndex

Power Unit Chassis Index
Name

powerUnitchassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.600.10.1.1

Description

Defines the index (one-based) of this chassis.

Syntax

DellObjectRange

Access

Read-only

Power Unit Index
Name

powerUnitIndex

Object ID

1.3.6.1.4.1.674.10892.1.600.10.1.2

Description

Defines the index of the power unit in this chassis.

Syntax

DellObjectRange

Access

Read-only

Power Unit State Capabilities
Name

powerUnitStateCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.600.10.1.3

Description

Defines the capabilities of the power unit.

Syntax

DellStateCapabilities

Access

Read-only

154

Power Group

Power Unit State Settings
Name

powerUnitStateSettings

Object ID

1.3.6.1.4.1.674.10892.1.600.10.1.4

Description

Defines the state and settings of the power unit.

Syntax

DellStateSettings

Access

Read-write

Power Unit Redundancy Status
Name

powerUnitRedundancyStatus

Object ID

1.3.6.1.4.1.674.10892.1.600.10.1.5

Description

Defines the redundancy status of the power unit.

Syntax

DellStatusRedundancy

Access

Read-only

Power Supply Count for Redundancy
Name

powerSupplyCountForRedundancy

Object ID

1.3.6.1.4.1.674.10892.1.600.10.1.6

Description

Defines the total number of power supplies required for this
power unit to have redundancy.

Syntax

DellString

Access

Read-only

Power Unit Name
Name

powerUnitName

Object ID

1.3.6.1.4.1.674.10892.1.600.10.1.7

Description

Defines the name of the power unit in this chassis.

Syntax

DellString

Access

Read-only

Power Group

155

Power Unit Status
Name

powerUnitStatus

Object ID

1.3.6.1.4.1.674.10892.1.600.10.1.8

Description

Defines the status of the power unit in this chassis.

Syntax

DellStatus

Access

Read-only

Power Supply Table
Name

powerSupplyTable

Object ID

1.3.6.1.4.1.674.10892.1.600.12

Description

Defines the Power Supply Table.

Syntax

PowerSupplyTableEntry

Access

Not accessible

Power Supply Table Entry
Name

powerSupplyTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.600.12.1

Description

Defines the Power Supply Table entry.

Syntax

PowerSupplyTableEntry

Access

Not accessible

Index

powerSupplychassisIndex, powerSupplyIndex

Power Supply Chassis Index
Name

powerSupplychassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.600.12.1.1

Description

Defines the index (one-based) of this chassis.

Syntax

DellObjectRange

Access

Read-only

156

Power Group

Power Supply Index
Name

powerSupplyIndex

Object ID

1.3.6.1.4.1.674.10892.1.600.12.1.2

Description

Defines the index of power supply.

Syntax

DellObjectRange

Access

Read-only

Power Supply State Capabilities Unique
Name

powerSupplyStateCapabilitiesUnique

Object ID

1.3.6.1.4.1.674.10892.1.600.12.1.3

Description

Defines the capabilities of the power supply.

Syntax

DellPowerSupplyStateCapabilitiesUnique (See Table 9-1)

Access

Read-only

Power Supply State Settings Unique
Name

powerSupplyStateSettingsUnique

Object ID

1.3.6.1.4.1.674.10892.1.600.12.1.4

Description

Defines the state and settings of the power supply.

Syntax

DellPowerSupplyStateSettingsUnique (See Table 9-2)

Access

Read-write

Power Supply Status
Name

powerSupplyStatus

Object ID

1.3.6.1.4.1.674.10892.1.600.12.1.5

Description

Defines the status of the power supply.

Syntax

DellStatus

Access

Read-only

Power Group

157

Power Supply Output Watts
Name

powerSupplyOutputWatts

Object ID

1.3.6.1.4.1.674.10892.1.600.12.1.6

Description

Defines the maximum sustained output wattage of the power
supply in tenths of watts.

Syntax

DellSigned32BitRange

Access

Read-only

Power Supply Type
Name

powerSupplyType

Object ID

1.3.6.1.4.1.674.10892.1.600.12.1.7

Description

Defines the type of power supply.

Syntax

DellPowerSupplyType (See Table 9-3)

Access

Read-only

Power Supply Location Name
Name

powerSupplyLocationName

Object ID

1.3.6.1.4.1.674.10892.1.600.12.1.8

Description

Defines the location name of the power supply.

Syntax

DellString

Access

Read-only

Power Supply Input Voltage
Name

powerSupplyInputVoltage

Object ID

1.3.6.1.4.1.674.10892.1.600.12.1.9

Description

Defines the input voltage to the power supply in volts.

Syntax

DellSigned32BitRange

Access

Read-only

158

Power Group

Power Supply Power Unit Index Reference
Name

powerSupplypowerUnitIndexReference

Object ID

1.3.6.1.4.1.674.10892.1.600.12.1.10

Description

Defines the index to the associated system power unit in this chassis.

Syntax

DellObjectRange

Access

Read-only

Power Supply Sensor State
Name

powerSupplySensorState

Object ID

1.3.6.1.4.1.674.10892.1.600.12.1.11

Description

Defines the state reported by the power supply sensor, and
supplements the state and settings of the power supply.

Syntax

DellPowerSupplySensorState (See Table 9-4)

Access

Read-only

Power Supply Configuration Error Type
Name

powerSupplyConfigurationErrorType

Object ID

1.3.6.1.4.1.674.10892.1.600.12.1.12

Description

Defines the type of configuration error reported by the power
supply sensor.

Syntax

DellPowerSupplyConfigurationErrorType (See Table 9-5)

Access

Read-only

Power Supply Power Monitor Capable
Name

powerSupplyPowerMonitorCapable

Object ID

1.3.6.1.4.1.674.10892.1.600.12.1.13

Description

Defines a boolean value that reports whether the power supply is
capable of monitoring power consumption.

Syntax

DellBoolean

Access

Read-only
Power Group

159

Power Supply Rated Input Wattage
Name

powerSupplyRatedInputWattage

Object ID

1.3.6.1.4.1.674.10892.1.600.12.1.14

Description

Defines the rated input wattage of the power supply (in tenths
of Watts.)

Syntax

DellSigned32BitRange

Access

Read-only

Voltage Probe Table
Name

voltageProbeTable

Object ID

1.3.6.1.4.1.674.10892.1.600.20

Description

Defines the Voltage Probe Table.

Syntax

VoltageProbeTableEntry

Access

Not accessible

Voltage Probe Table Entry
Name

voltageProbeTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.600.20.1

Description

Defines the Voltage Probe Table entry.

Syntax

VoltageProbeTableEntry

Access

Not accessible

Index

voltageProbechassisIndex, voltageProbeIndex

Voltage Probe Chassis Index
Name

voltageProbechassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.600.20.1.1

Description

Defines the index (one-based) of this chassis.

Syntax

DellObjectRange

Access

Read-only

160

Power Group

Voltage Probe Index
Name

voltageProbeIndex

Object ID

1.3.6.1.4.1.674.10892.1.600.20.1.2

Description

Defines the index of voltage probes in this chassis.

Syntax

DellObjectRange

Access

Read-only

Voltage Probe State Capabilities
Name

voltageProbeStateCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.600.20.1.3

Description

Defines the capabilities of the voltage probe.

Syntax

DellStateCapabilities

Access

Read-only

Voltage Probe State Settings
Name

voltageProbeStateSettings

Object ID

1.3.6.1.4.1.674.10892.1.600.20.1.4

Description

Defines the state and settings of the voltage probe.

Syntax

DellStateSettings

Access

Read-write

Voltage Probe Status
Name

voltageProbeStatus

Object ID

1.3.6.1.4.1.674.10892.1.600.20.1.5

Description

Defines the status of the voltage probe.

Syntax

DellStatusProbe

Access

Read-only

Power Group

161

Voltage Probe Reading
Name

voltageProbeReading

Object ID

1.3.6.1.4.1.674.10892.1.600.20.1.6

Description

Defines the value of the voltage probe reading. The value is an integer
representing the voltage in millivolts that the probe is reading.
When the value for voltageProbeType is voltageProbeTypeIsDiscrete,
a value is not returned for this attribute.

Syntax

DellSigned32BitRange

Access

Read-only

Voltage Probe Type
Name

voltageProbeType

Object ID

1.3.6.1.4.1.674.10892.1.600.20.1.7

Description

Defines the type of the voltage probe.

Syntax

DellVoltageType

Access

Read-only

Voltage Probe Location Name
Name

voltageProbeLocationName

Object ID

1.3.6.1.4.1.674.10892.1.600.20.1.8

Description

Defines the location of the voltage probe in this chassis.

Syntax

DellString

Access

Read-only

Voltage Probe Upper Nonrecoverable Threshold
Name

voltageProbeUpperNonRecoverableThreshold

Object ID

1.3.6.1.4.1.674.10892.1.600.20.1.9

Description

Defines the value of the voltage probe’s upper nonrecoverable
threshold.

Syntax

DellSigned32BitRange

162

Power Group

Name

voltageProbeUpperNonRecoverableThreshold

Access

Read-only

Voltage Probe Upper Critical Threshold
Name

voltageProbeUpperCriticalThreshold

Object ID

1.3.6.1.4.1.674.10892.1.600.20.1.10

Description

Defines the value of the voltage probe’s upper critical threshold.

Syntax

DellSigned32BitRange

Access

Read-only

Voltage Probe Upper Noncritical Threshold
Name

voltageProbeUpperNonCriticalThreshold

Object ID

1.3.6.1.4.1.674.10892.1.600.20.1.11

Description

Defines the user-assigned value of the voltage probe’s upper
noncritical threshold.

Syntax

DellSigned32BitRange

Access

Read-write

Voltage Probe Lower Noncritical Threshold
Name

voltageProbeLowerNonCriticalThreshold

Object ID

1.3.6.1.4.1.674.10892.1.600.20.1.12

Description

Defines the user-assigned value of the voltage probe’s lower
noncritical threshold.

Syntax

DellSigned32BitRange

Access

Read-write

Power Group

163

Voltage Probe Lower Critical Threshold
Name

voltageProbeLowerCriticalThreshold

Object ID

1.3.6.1.4.1.674.10892.1.600.20.1.13

Description

Defines the value of the voltage probe’s lower critical threshold.

Syntax

DellSigned32BitRange

Access

Read-only

Voltage Probe Lower Nonrecoverable Threshold
Name

voltageProbeLowerNonRecoverableThreshold

Object ID

1.3.6.1.4.1.674.10892.1.600.20.1.14

Description

Defines the value of the voltage probe’s lower nonrecoverable
threshold.

Syntax

DellSigned32BitRange

Access

Read-only

Voltage Probe Probe Capabilities
Name

voltageProbeProbeCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.600.20.1.15

Description

Defines the probe capabilities of the voltage probe.

Syntax

DellProbeCapabilities

Access

Read-only

164

Power Group

Voltage Probe Discrete Reading
Name

voltageProbeDiscreteReading

Object ID

1.3.6.1.4.1.674.10892.1.600.20.1.16

Description

Defines the reading for a voltage probe of type
voltageProbeTypeIsDiscrete.
When the value for voltageProbeType is other than
voltageProbeTypeIsDiscrete, a value is not returned for this
attribute. When the value for voltageProbeType is
voltageProbeTypeIsDiscrete, the value returned for this attribute
is the discrete reading for the probe.

Syntax

DellVoltageDiscreteReading

Access

Read-only

Amperage Probe Table
Name

amperageProbeTable

Object ID

1.3.6.1.4.1.674.10892.1.600.30

Description

Defines the Amperage Probe Table.

Syntax

SEQUENCE OF AmperageProbeTableEntry

Access

Not accessible

Amperage Probe Table Entry
Name

amperageProbeTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.600.30.1

Description

Defines the Amperage Probe Table entry.

Syntax

AmperageProbeTableEntry

Access

Not accessible

Index

amperageProbechassisIndex, amperageProbeIndex

Power Group

165

Amperage Probe Chassis Index
Name

amperageProbechassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.600.30.1.1

Description

Defines the index (one-based) of this chassis.

Syntax

DellObjectRange

Access

Read-only

Amperage Probe Index
Name

amperageProbeIndex

Object ID

1.3.6.1.4.1.674.10892.1.600.30.1.2

Description

Defines the index of amperage probes in this chassis.

Syntax

DellObjectRange

Access

Read-only

Amperage Probe State Capabilities
Name

amperageProbeStateCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.600.30.1.3

Description

Defines the capabilities of the amperage probe.

Syntax

DellStateCapabilities

Access

Read-only

Amperage Probe State Settings
Name

amperageProbeStateSettings

Object ID

1.3.6.1.4.1.674.10892.1.600.30.1.4

Description

Defines the state and settings of the amperage probe.

Syntax

DellStateSettings

Access

Read-write

166

Power Group

Amperage Probe Status
Name

amperageProbeStatus

Object ID

1.3.6.1.4.1.674.10892.1.600.30.1.5

Description

Defines the status of the amperage probe.

Syntax

DellSigned32BitRange

Access

Read-only

Amperage Probe Reading
Name

amperageProbeReading

Object ID

1.3.6.1.4.1.674.10892.1.600.30.1.6

Description

Defines the reading for an amperage probe of type other than
amperageProbeTypeIsDiscrete.
When the value for amperageProbeType is
amperageProbeTypeIsPowerSupplyAmps or
amperageProbeTypeIsSystemAmps, the value returned for this
attribute is the power usage that the probe is reading in tenths
of Amperes.
When the value for amperageProbeType is
amperageProbeTypeIsPowerSupplyWatts or
amperageProbeTypeIsSystemWatts, the value returned for this
attribute is the power usage that the probe is reading in Watts.
When the value for amperageProbeType is other than
amperageProbeTypeIsDiscrete,
amperageProbeTypeIsPowerSupplyAmps,
amperageProbeTypeIsPowerSupplyWatts,
amperageProbeTypeIsSystemAmps, or
amperageProbeTypeIsSystemWatts, the value returned for this
attribute is the amperage that the probe is reading in Milliamps.
When the value for amperageProbeType is
amperageProbeTypeIsDiscrete, a value is not returned for this
attribute.

Syntax

DellSigned32BitRange

Access

Read-only

Power Group

167

Amperage Probe Type
Name

amperageProbeType

Object ID

1.3.6.1.4.1.674.10892.1.600.30.1.7

Description

Defines the type of the amperage probe.

Syntax

DellAmperageProbeType

Access

Read-only

Amperage Probe Location Name
Name

amperageProbeLocationName

Object ID

1.3.6.1.4.1.674.10892.1.600.30.1.8

Description

Defines the location name of the amperage probe in this chassis.

Syntax

DellString

Access

Read-only

Amperage Probe Upper Nonrecoverable Threshold
Name

amperageProbeUpperNonRecoverableThreshold

Object ID

1.3.6.1.4.1.674.10892.1.600.30.1.9

Description

Defines the value of the amperage probe’s upper nonrecoverable
threshold. The value is an integer representing the amperage in
milliamperes that the probe is reading.

Syntax

DellSigned32BitRange

Access

Read-only

Amperage Probe Upper Critical Threshold
Name

amperageProbeUpperCriticalThreshold

Object ID

1.3.6.1.4.1.674.10892.1.600.30.1.10

Description

Defines the value of the amperage probe’s upper critical threshold.

Syntax

DellSigned32BitRange

Access

Read-only

168

Power Group

Amperage Probe Upper Noncritical Threshold
Name

amperageProbeUpperNonCriticalThreshold

Object ID

1.3.6.1.4.1.674.10892.1.600.30.1.11

Description

Defines the user-assigned value of the amperage probe’s upper
critical threshold.

Syntax

DellSigned32BitRange

Access

Read-write

Amperage Probe Lower Noncritical Threshold
Name

amperageProbeLowerNonCriticalThreshold

Object ID

1.3.6.1.4.1.674.10892.1.600.30.1.12

Description

Defines the user-assigned value of the amperage probe’s lower
noncritical threshold.

Syntax

DellSigned32BitRange

Access

Read-write

Amperage Probe Lower Critical Threshold
Name

amperageProbeLowerCriticalThreshold

Object ID

1.3.6.1.4.1.674.10892.1.600.30.1.13

Description

Defines the value of the amperage probe’s lower
critical threshold.

Syntax

DellSigned32BitRange

Access

Read-only

Power Group

169

Amperage Probe Lower Nonrecoverable Threshold
Name

amperageProbeLowerNonRecoverableThreshold

Object ID

1.3.6.1.4.1.674.10892.1.600.30.1.14

Description

Defines the value of the amperage probe’s lower
nonrecoverable threshold.

Syntax

DellSigned32BitRange

Access

Read-only

Amperage Probe Probe Capabilities
Name

amperageProbeProbeCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.600.30.1.15

Description

Defines the probe capabilities of the amperage probe.

Syntax

DellProbeCapabilities

Access

Read-only

Amperage Probe Discrete Reading
Name

amperageProbeDiscreteReading

Object ID

1.3.6.1.4.1.674.10892.1.600.30.1.16

Description

Defines the reading for a amperage probe of type
amperageProbeTypeIsDiscrete.
When the value for amperageProbeType is other than
amperageProbeTypeIsDiscrete, a value is not returned for this
attribute. When the value for amperageProbeType is
amperageProbeTypeIsDiscrete, the value returned for this
attribute is the discrete reading for the probe.

Syntax

DellAmperageDiscreteReading (See Table 9-9)

Access

Read-only

170

Power Group

AC Power Switch Table
Name

aCPowerSwitchTable

Object ID

1.3.6.1.4.1.674.10892.1.600.40

Description

Defines the AC Power Switch Table.

Syntax

SEQUENCE OF ACPowerSwitchTableEntry

Access

Not accessible

AC Power Switch Table Entry
Name

aCPowerSwitchTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.600.40.1

Description

Defines the AC Power Switch Table entry.

Syntax

ACPowerSwitchTableEntry

Access

Not accessible

Index

aCPowerSwitchchassisIndex, aCPowerSwitchIndex

AC Power Switch Chassis Index
Name

aCPowerSwitchChassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.600.40.1.1

Description

Defines the index (one-based) of the chassis containing this
AC power switch.

Syntax

DellObjectRange

Access

Read-only

AC Power Switch Index
Name

aCPowerSwitchIndex

Object ID

1.3.6.1.4.1.674.10892.1.600.40.1.2

Description

Defines the index (one-based) of this AC power switch.

Syntax

DellObjectRange

Access

Read-only

Power Group

171

AC Power Switch Capabilities
Name

aCPowerSwitchCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.600.40.1.3

Description

Defines the capabilities of this AC power switch.

Syntax

DellACPowerSwitchCapabilities

Access

Read-only

AC Power Switch Settings
Name

aCPowerSwitchSettings

Object ID

1.3.6.1.4.1.674.10892.1.600.40.1.4

Description

Defines the settings of this AC power switch.

Syntax

DellACPowerSwitchSettings

Access

Read-write

AC Power Switch Redundancy Status
Name

aCPowerSwitchRedundancyStatus

Object ID

1.3.6.1.4.1.674.10892.1.600.40.1.5

Description

Defines the redundancy status of this AC power switch.

Syntax

DellStatusRedundancy

Access

Read-only

AC Power Cord Count for Redundancy
Name

aCPowerCordCountForRedundancy

Object ID

1.3.6.1.4.1.674.10892.1.600.40.1.6

Description

Defines the total number of AC power cords required for this
AC power switch to have redundancy.

Syntax

DellObjectRange

Access

Read-only

172

Power Group

AC Power Switch Name
Name

aCPowerSwitchName

Object ID

1.3.6.1.4.1.674.10892.1.600.40.1.7

Description

Defines the name of this AC power switch.

Syntax

DellString

Access

Read-only

AC Power Switch Redundancy Mode
Name

aCPowerSwitchRedundancyMode

Object ID

1.3.6.1.4.1.674.10892.1.600.40.1.8

Description

Defines the redundancy mode of this AC power switch.

Syntax

DellACPowerSwitchRedundancyMode

Access

Read-write

AC Power Switch Status
Name

aCPowerSwitchStatus

Object ID

1.3.6.1.4.1.674.10892.1.600.40.1.9

Description

Defines the status of this AC power switch.

Syntax

DellStatus

Access

Read-only

AC Power Cord Table
Name

aCPowerCordTable

Object ID

1.3.6.1.4.1.674.10892.1.600.42

Description

Defines the AC Power Cord Table.

Syntax

SEQUENCE OF ACPowerCordTableEntry

Access

Not accessible

Power Group

173

AC Power Cord Table Entry
Name

aCPowerCordTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.600.42.1

Description

Defines the AC Power Cord Table entry.

Syntax

ACPowerCordTableEntry

Access

Not accessible

Index

aCPowerCordchassisIndex, aCPowerCordIndex

AC Power Cord Chassis Index
Name

aCPowerCordChassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.600.42.1.1

Description

Defines the index (one-based) of the chassis containing this
AC power cord.

Syntax

DellObjectRange

Access

Read-only

AC Power Cord Index
Name

aCPowerCordIndex

Object ID

1.3.6.1.4.1.674.10892.1.600.42.1.2

Description

Defines the index (one-based) of this AC power cord.

Syntax

DellObjectRange

Access

Read-only

AC Power Cord State Capabilities
Name

aCPowerCordStateCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.600.42.1.3

Description

Defines the capabilities of this AC power cord.

Syntax

DellACPowerCordStateCapabilities

Access

Read-only

174

Power Group

AC Power Cord State Settings
Name

aCPowerCordStateSettings

Object ID

1.3.6.1.4.1.674.10892.1.600.42.1.4

Description

Defines the settings of this AC power cord.

Syntax

DellACPowerCordStateSettings

Access

Read-write

AC Power Cord Status
Name

aCPowerCordStatus

Object ID

1.3.6.1.4.1.674.10892.1.600.42.1.5

Description

Defines the status of this AC power cord.

Syntax

DellStatus

Access

Read-only

AC Power Cord AC Power Switch Index Reference
Name

aCPowerCordaCPowerSwitchIndexReference

Object ID

1.3.6.1.4.1.674.10892.1.600.42.1.6

Description

Defines the index (one-based) to the associated AC power switch
for this AC power cord.

Syntax

DellObjectRange

Access

Read-only

AC Power Cord Location Name
Name

aCPowerCordLocationName

Object ID

1.3.6.1.4.1.674.10892.1.600.42.1.7

Description

Defines the location name of this AC power cord.

Syntax

DellString

Access

Read-only

Power Group

175

Battery Table
Name

batteryTable

Object ID

1.3.6.1.4.1.674.10892.1.600.50

Description

Defines the Battery Table.

Syntax

SEQUENCE OF BatteryTableEntry

Access

Not accessible

Battery Table Entry
Name

batteryTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.600.50.1

Description

Defines the Battery Table Entry.

Syntax

BatteryTableEntry

Access

Not accessible

Index

batteryChassisIndex, batteryIndex

Battery Chassis Index
Name

batteryChassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.600.50.1.1

Description

Defines the index (one-based) of the chassis that contains the
battery.

Syntax

DellObjectRange

Access

Read-only

Battery Index
Name

batteryIndex

Object ID

1.3.6.1.4.1.674.10892.1.600.50.1.2

Description

Defines the index (one-based) of the battery.

Syntax

DellObjectRange

Access

Read-only

176

Power Group

Battery State Capabilities
Name

batteryStateCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.600.50.1.3

Description

Defines the state capabilities of the battery.

Syntax

DellStateCapabilities

Access

Read-only

Battery State Settings
Name

batteryStateSettings

Object ID

1.3.6.1.4.1.674.10892.1.600.50.1.4

Description

Defines the state settings of the battery.

Syntax

DellStateSettings

Access

Read-write

Battery Status
Name

batteryStatus

Object ID

1.3.6.1.4.1.674.10892.1.600.50.1.5

Description

Defines the status of the battery.

Syntax

DellStatus

Access

Read-only

Battery Reading
Name

batteryReading

Object ID

1.3.6.1.4.1.674.10892.1.600.50.1.6

Description

Defines the reading of the battery.

Syntax

DellBatteryReading (see Table 9-15)

Access

Read-only

Power Group

177

Battery Location Name
Name

batteryLocationName

Object ID

1.3.6.1.4.1.674.10892.1.600.50.1.7

Description

Defines the location of the battery.

Syntax

DellString

Access

Read-only

Power Usage Table
Name

powerUsageTable

Object ID

1.3.6.1.4.1.674.10892.1.600.60

Description

Defines the Power Usage Table.

Syntax

SEQUENCE OF PowerUsageTableEntry

Access

Not accessible

Power Usage Table Entry
Name

powerUsageTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.600.60.1

Description

Defines the Power Usage Table Entry.

Syntax

PowerUsageTableEntry

Access

Not accessible

Index

powerUsageChassisIndex, powerUsageIndex

Power Usage Chassis Index
Name

powerUsageChassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.600.60.1.1

Description

Defines the index (one-based) of the associated chassis.

Syntax

DellObjectRange

Access

Read-only

178

Power Group

Power Usage Index
Name

powerUsageIndex

Object ID

1.3.6.1.4.1.674.10892.1.600.60.1.2

Description

Defines the index (one-based) of the power usage information.

Syntax

DellObjectRange

Access

Read-only

Power Usage State Capabilities
Name

powerUsageStateCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.600.60.1.3

Description

Defines the state capabilities of the power usage information.

Syntax

DellStateCapabilities

Access

Read-only

Power Usage State Settings
Name

powerUsageStateSettings

Object ID

1.3.6.1.4.1.674.10892.1.600.60.1.4

Description

Defines the state settings of the power usage information.

Syntax

DellStateSettings

Access

Read-write

Power Usage Status
Name

powerUsageStatus

Object ID

1.3.6.1.4.1.674.10892.1.600.60.1.5

Description

Defines the status of the power usage information.

Syntax

DellStatus

Access

Read-only

Power Group

179

Power Usage Entity Name
Name

powerUsageEntityName

Object ID

1.3.6.1.4.1.674.10892.1.600.60.1.6

Description

Defines the name of the entity associated with this power usage
information.

Syntax

DellString

Access

Read-only

Power Usage Cumulative Wattage
Name

powerUsageCumulativeWattage

Object ID

1.3.6.1.4.1.674.10892.1.600.60.1.7

Description

Defines the total wattage used (in Watt-hours) by this entity
since the date and time specified by the
powerUsageCumulativeWattageStartDateName attribute.

Syntax

DellUnsigned32BitRange

Access

Read-only

Power Usage Cumulative Wattage Start Date Name
Name

powerUsageCumulativeWattageStartDateName

Object ID

1.3.6.1.4.1.674.10892.1.600.60.1.8

Description

Defines the date and time at which the data collection started
for the value reported by the powerUsageCumulativeWattage
attribute.

Syntax

DellDateName

Access

Read-only

Power Usage Peak Watts
Name

powerUsagePeakWatts

Object ID

1.3.6.1.4.1.674.10892.1.600.60.1.9

180

Power Group

Name

powerUsagePeakWatts

Description

Defines the peak wattage reading (in Watts) for this entity
since the date and time specified by the
powerUsagePeakWattsStartDateName attribute.

Syntax

DellUnsigned32BitRange

Access

Read-only

Power Usage Peak Watts Start Date Name
Name

powerUsagePeakWattsStartDateName

Object ID

1.3.6.1.4.1.674.10892.1.600.60.1.10

Description

Defines the date and time at which the data collection started
for the value reported by the powerUsagePeakWatts attribute.

Syntax

DellDateName

Access

Read-only

Power Usage Peak Watts Reading Date Name
Name

powerUsagePeakWattsReadingDateName

Object ID

1.3.6.1.4.1.674.10892.1.600.60.1.11

Description

Defines the date and time at which the value reported by the
powerUsagePeakWatts attribute was measured.

Syntax

DellDateName

Access

Read-only

Power Usage Peak Amps
Name

powerUsagePeakAmps

Object ID

1.3.6.1.4.1.674.10892.1.600.60.1.12

Description

Defines the peak amperage reading (in tenths of Amps) for this
entity since the date and time specified by the
powerUsagePeakAmpsStartDateName attribute.

Syntax

DellUnsigned32BitRange

Access

Read-only
Power Group

181

Power Usage Peak Amps Start Date Name
Name

powerUsagePeakAmpsStartDateName

Object ID

1.3.6.1.4.1.674.10892.1.600.60.1.13

Description

Defines the date and time at which the data collection started
for the value reported by the powerUsagePeakAmps attribute.

Syntax

DellDateName

Access

Read-only

Power Usage Peak Amps Reading Date Name
Name

powerUsagePeakAmpsReadingDateName

Object ID

1.3.6.1.4.1.674.10892.1.600.60.1.14

Description

Defines the date and time at which the value reported by the
powerUsagePeakAmps attribute was measured.

Syntax

DellDateName

Access

Read-only

Power Usage Idle Power
Name

powerUsageIdlePower

Object ID

1.3.6.1.4.1.674.10892.1.600.60.1.15

Description

Defines the system idle power (in Watts). This is the minimum
power the system can consume based on the current hardware
configuration.

Syntax

DellUnsigned32BitRange

Access

Read-only

Power Usage Max Potential Power
Name

powerUsageMaxPotentialPower

Object ID

1.3.6.1.4.1.674.10892.1.600.60.1.16

182

Power Group

Name

powerUsageMaxPotentialPower

Description

Defines the maximum potential power (in Watts) of the system.
This is the maximum power the system can consume based on
the current hardware configuration.

Syntax

DellUnsigned32BitRange

Access

Read-only

Power Usage Power Cap Capabilities
Name

powerUsagePowerCapCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.600.60.1.17

Description

Defines the system power cap capabilities.

Syntax

DellPowerCapCapabilities

Access

Read-only

Power Usage Power Cap Setting
Name

powerUsagePowerCapSetting

Object ID

1.3.6.1.4.1.674.10892.1.600.60.1.18

Description

Defines the system power cap setting.

Syntax

DellPowerCapSetting

Access

Read-only

Power Usage Power Cap Value
Name

powerUsagePowerCapValue

Object ID

1.3.6.1.4.1.674.10892.1.600.60.1.19

Description

Defines the system power cap value (in Watts).

Syntax

DellUnsigned32BitRange

Access

Read-only

Power Group

183

Power Usage Instantaneous Headroom
Name

powerUsageInstantaneousHeadroom

Object ID

1.3.6.1.4.1.674.10892.1.600.60.1.20

Description

Defines the system instantaneous headroom (in Watts). This is
the theoretical maximum power drawn by the power supply
minus instantaneous power draw.

Syntax

DellUnsigned32BitRange

Access

Read-only

Power Usage Peak Headroom
Name

powerUsagePeakHeadroom

Object ID

1.3.6.1.4.1.674.10892.1.600.60.1.21

Description

Defines the system peak headroom (in Watts). This is the
theoretical maximum power drawn by the power supply minus
peak power draw.

Syntax

DellUnsigned32BitRange

Access

Read-only

Power Profile Table
Name

powerProfileTable

Object ID

1.3.6.1.4.1.674.10892.1.600.70

Description

Defines the Power Profile Table.

Syntax

SEQUENCE OF PowerProfileTableEntry

Access

Not accessible

Power Profile Table Entry
Name

powerProfileTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.600.70.1

Description

Defines the Power Profile Table Entry.

Syntax

PowerProfileTableEntry

184

Power Group

Name

powerProfileTableEntry

Access

Not accessible

Index

powerProfileChassisIndex, powerProfileIndex

Power Profile Chassis Index
Name

powerProfileChassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.600.70.1.1

Description

Defines the index (one-based) of the associated chassis.

Syntax

DellObjectRange

Access

Read-only

Power Profile Index
Name

powerProfileIndex

Object ID

1.3.6.1.4.1.674.10892.1.600.70.1.2

Description

Defines the index (one-based) of the power profile information.

Syntax

DellObjectRange

Access

Read-only

Power Profile Supported Profiles
Name

powerProfileSupportedProfiles

Object ID

1.3.6.1.4.1.674.10892.1.600.70.1.3

Description

Defines the supported power profiles.

Syntax

DellPowerProfileType

Access

Read-only

Power Profile Setting
Name

powerProfileSetting

Object ID

1.3.6.1.4.1.674.10892.1.600.70.1.4

Description

Defines the power profile setting.

Power Group

185

Name

powerProfileSetting

Syntax

DellPowerProfileType

Access

Read-only

Power Profile Custom CPU Management Capabilities
Name

powerProfileCustomCPUManagementCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.600.70.1.5

Description

Defines the custom CPU power and performance management
capabilities that are available for the Custom power profile.

Syntax

DellCPUPowerPerformanceManagementType

Access

Read-only

Power Profile Custom CPU Management Setting
Name

powerProfileCustomCPUManagementSetting

Object ID

1.3.6.1.4.1.674.10892.1.600.70.1.6

Description

Defines the custom CPU power and performance management
setting for the Custom power profile.

Syntax

DellCPUPowerPerformanceManagementType

Access

Read-only

Power Profile Custom Memory Management Capabilities
Name

powerProfileCustomMemoryManagementCapabiliti
es

Object ID

1.3.6.1.4.1.674.10892.1.600.70.1.7

Description

Defines the custom memory power and performance
management capabilities that are available for the Custom
power profile.

Syntax

DellMemoryPowerPerformanceManagementType

Access

Read-only

186

Power Group

Power Profile Custom Memory Management Setting
Name

powerProfileCustomMemoryManagementSetting

Object ID

1.3.6.1.4.1.674.10892.1.600.70.1.8

Description

Defines the custom memory power and performance
management setting for the Custom power profile.

Syntax

DellMemoryPowerPerformanceManagementType

Access

Read-only

Power Profile Custom Fan Management Capabilities
Name

powerProfileCustomFanManagementCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.600.70.1.9

Description

Defines the custom fan power and performance management
capabilities that are available for the Custom power profile.

Syntax

DellFanPowerPerformanceManagementType

Access

Read-only

Power Profile Custom Fan Management Setting
Name

powerProfileCustomFanManagementSetting

Object ID

1.3.6.1.4.1.674.10892.1.600.70.1.10

Description

Defines the custom fan power and performance management
setting for the Custom power profile.

Syntax

DellFanPowerPerformanceManagementType

Access

Read-only

Power Group Variable Values
This section includes definitions for server administrator-specific variable
values used in this section.

Power Group

187

Table 9-1. Power Supply State Capabilities Unique
Variable Name: DellPowerSupplyStateCapabilitiesUnique
Data Type: Integer
Possible Data Values

Meaning of Data Value

unknown(1)

The power supply’s capabilities are unknown.

onlineCapable(2)

The power supply can be disabled (offline, a binary
0 value) or enabled (online, a binary 1 value).

notReadyCapable(4)

The power supply’s capabilities are not ready.

Table 9-2. Power Supply State Settings Unique
Variable Name: DellPowerSupplyStateSettingsUnique
Data Type: Integer
Possible Data Values

Meaning of Data Value

unknown(1)

The power supply’s capabilities are unknown.

onLine(2)

The power supply’s state is disabled (offline, a
binary 0 value) or enabled (online, a binary 1 value).

notReady(4)

The power supply’s state is not ready.

fanFailure(8)

The power supply fan has failed.

onlineAndFanFailure(10) The power supply is online and indicating that its
fan is not working.
powerSupplyIsON(16)

The power supply is indicating that it is on.

powerSupplyIsOk(32)

The power supply is indicating that it is OK.

acSwitchIsON(64)

The power supply is indicating that the AC power
switch is on.

onlineandAcSwitchIsON The power supply is online and indicating that the
(66)
AC power supply switch capability is activated.
acPowerIsON(128)

The power supply is indicating that the AC power
is on.

onlineAndAcPowerIsON
(130)

The power supply is online and indicating that the
AC power is on.

188

Power Group

Table 9-2. Power Supply State Settings Unique (continued)
Variable Name: DellPowerSupplyStateSettingsUnique
Data Type: Integer
Possible Data Values

Meaning of Data Value

onlineAndPredictiveFail The power supply is online and indicating that it
ure(210)
has a problem.
acPowerAndSwitchAreOn The power supply is online and OK.
PowerSupplyIsOnIsOkAnd
Online(242)
Table 9-3. Power Supply Type Definitions
Variable Name: DellPowerSupplyType
Data Type: Integer
Possible Data Values

Meaning of Data Value

powerSupplyTypeIsOther(1)

The power supply type is not one of
the following:

powerSupplyTypeIsUnknown(2)

The power supply type is unknown
(not known or not monitored).

powerSupplyTypeIsLinear(3)

The power supply type is a linear
power supply.

powerSupplyTypeIsSwitching(4) The power supply type is a switching
power supply.
powerSupplyTypeIsBattery(5)

The power supply type is a battery.

powerSupplyTypeIsUPS(6)

The power supply type is an
uninterruptable power supply.

powerSupplyTypeIsConverter(7) The power supply type is a power
converter power supply.
powerSupplyTypeIsRegulator(8) The power supply type is a regulator
power supply.
powerSupplyTypeIsAC(9)

The power supply type is an AC power
supply.

Power Group

189

Table 9-3. Power Supply Type Definitions (continued)
Variable Name: DellPowerSupplyType
Data Type: Integer
Possible Data Values

Meaning of Data Value

powerSupplyTypeIsDC(10)

The power supply type is a DC power
supply.

powerSupplyTypeIsVRM(11)

The power supply type is a voltage
regulator module (VRM) power
supply.

Table 9-4. Power Supply Sensor State
Variable Name: DellPowerSupplySensorState
Data Type: Integer
Possible Data Values

Meaning of Data Value

presenceDetected(1)

The power supply’s presence is detected.

psFailureDetected(2)

The power supply failure is detected.

predictiveFailure(4)

The power supply sensor detects predictive
failure

psACLost(8)

The power supply’s AC power is lost.

acLostOrOutOfRange(16)

The power supply’s AC power is lost or out
of range.

acOutOfRangeButPresent(32) The power supply’s AC power is present, but
it is out of range.
configurationError(64)

190

Power Group

The power supply sensor detects a
configuration error.

Table 9-5. Power Supply Configuration Error Type
Variable Name: DellPowerSupplyConfigurationErrorType
Data Type: Integer
Possible Data Values

Meaning of Data Value

vendorMismatch(1)

The power supply configuration error type is
vendor mismatch.

revisionMismatch(2)

The power supply configuration error type is
revision mismatch.

processorMissing(3)

The power supply configuration error type is
processor missing.

Table 9-6. Voltage Probe Type
Variable Name: DellVoltageType
Data Type: Integer
Possible Data Values

Meaning of Data Value

voltageProbeTypeIsOther(1)

The voltage probe type is not one of the
following:

voltageProbeTypeIsUnknown(2) The voltage probe type is unknown
(not known or not monitored).
voltageProbeTypeIs1Point5Volt The voltage probe type is a 1.5-volt (V)
(3)
probe.
voltageProbeTypeIs3Point3Volt The voltage probe type is a 3.3-V probe.
(4)
voltageProbeTypeIs5Volt(5)

The voltage probe type is a 5-V probe.

voltageProbeTypeIsMinus5Volt The voltage probe type is a –5-V probe.
(6)
voltageProbeTypeIs12Volt(7)

The voltage probe type is a 12-V probe.

voltageProbeTypeIsMinus12Volt The voltage probe type is a –12-V probe.
(8)
voltageProbeTypeIsIO(9)

The voltage probe type is an I/O volt
probe.

Power Group

191

Table 9-6. Voltage Probe Type (continued)
Variable Name: DellVoltageType
Data Type: Integer
Possible Data Values

Meaning of Data Value

voltageProbeTypeIsCore(10)

The voltage probe type is a core volt
probe.

voltageProbeTypeIsFLEA(11)

The voltage probe type is a FLEA
(standby) volt probe.

voltageProbeTypeIsBattery(12) The voltage probe type is a battery volt
probe.
voltageProbeTypeIsTerminator The voltage probe type is a SCSI
(13)
termination volt probe.
voltageProbeTypeIs2Point5Volt The voltage probe type is a 2.5-V probe.
(14)
The voltage probe type is a ground
termination logic (GTL) probe.

voltageProbeTypeIsGTL(15)

voltageProbeTypeIsDiscrete(16) The voltage probe type is a voltage probe
with discrete reading.
Table 9-7. Voltage Probe Discrete Reading
Variable Name: DellVoltageDiscreteReading
Data Type: Integer
Possible Data Values

Meaning of Data Value

voltageIsGood(1)

The voltage probe discrete reading is good.

voltageIsBad(2)

The voltage probe discrete reading is bad.

192

Power Group

Table 9-8. Amperage Probe Definitions
Variable Name: DellAmperageType
Data Type: Integer
Possible Data Values

Meaning of Data Value

amperageProbeTypeIsOther(1)

The amperage probe type is
not one of the following:

amperageProbeTypeIsUnknown(2)

The amperage probe type is
unknown (not known or
not monitored).

amperageProbeTypeIs1Point5Volt(3)

The amperage probe type is a
1.5-ampere (A) probe.

amperageProbeTypeIs3Point3volt(4)

The amperage probe type is a
3.3-A probe.

amperageProbeTypeIs5Volt(5)

The amperage probe type is a
5-A probe.

amperageProbeTypeIsMinus5Volt(6)

The amperage probe type is a
–5-A probe.

amperageProbeTypeIs12Volt(7)

The amperage probe type is a
12-A probe.

amperageProbeTypeIsMinus12Volt(8)

The amperage probe type is a
–12-A probe.

amperageProbeTypeIsIO(9)

The amperage probe type is an
I/O amperage probe.

amperageProbeTypeIsCore(10)

The amperage probe type is a
core amperage probe.

amperageProbeTypeIsFLEA(11)

The amperage probe type is a
FLEA (standby) amperage
probe.

amperageProbeTypeIsBattery(12)

The amperage probe type is a
battery amperage probe.

amperageProbeTypeIsTerminator(13)

The amperage probe type is a
Small Computer System
Interface (SCSI) termination
amperage probe.
Power Group

193

Table 9-8. Amperage Probe Definitions (continued)
Variable Name: DellAmperageType
Data Type: Integer
Possible Data Values

Meaning of Data Value

amperageProbeTypeIs2Point5Volt(14)

The amperage probe type is a
2.5-V amperage probe.

amperageProbeTypeIsGTL(15)

The amperage probe type is a
Gunning Transceiver Logic
(GTL) probe.

amperageProbeTypeIsDiscrete(16)

The amperage probe type is an
amperage probe with
discrete reading.

amperageProbeTypeIsPowerSupplyAmps(23) The amperage probe type is
power supply probe with
reading in Amperes.
amperageProbeTypeIsPowerSupplyWatts The amperage probe type is
(24)
power supply probe with
reading in Watts.
amperageProbeTypeIsSystemAmps(25)

The amperage probe type is
system probe with reading in
Amperes.

amperageProbeTypeIsSystemWatts(26)

The amperage probe type is
system probe with reading in
Watts.

Table 9-9. Amperage Probe Discrete Reading
Variable Name: DellAmperageDiscreteReading
Data Type: Integer
Possible Data Values

Meaning of Data Value

amperageIsGood(1)

The amperage probe discrete reading is good.

amperageIsBad(2)

The amperage probe discrete reading is bad.

194

Power Group

Table 9-10.

AC Power Switch Capabilities

Variable Name: DellACPowerSwitchCapabilities
Data Type: Integer
Possible Data Values

Meaning of Data Value

unknownCapabilities(1)

The AC power switch’s capabilities
are unknown.

inputSourceCord1NoReturnCapable(2) Input source is AC power cord 1,
with no return.
inputSourceCord1ReturnCapable(4)

Input source is AC power cord 1,
with return.

inputSourceCord2NoReturnCapable(8) Input source is AC power cord 2,
with no return.
inputSourceCord2ReturnCapable(16)

Input source is AC power cord 2,
with return.

inputSourceSharedCapable(32)

Input source is shared.

Table 9-11.

AC Power Switch Settings

Variable Name: DellACPowerSwitchSettings
Data Type: Integer
Possible Data Values

Meaning of Data Value

unknown(1)

The AC power switch’s settings are unknown.

inputSourceCord1NoReturn(2) Input source is AC power cord 1, with no return.
inputSourceCord1Return(4)

Input source is AC power cord 1, with return.

inputSourceCord2NoReturn(8) Input source is AC power cord 2, with no return.
inputSourceCord2Return(16)

Input source is AC power cord 2, with return.

inputSourceShared(32)

Input source is shared.

Power Group

195

Table 9-12. AC Power Switch Redundancy Mode
Variable Name: DellACPowerSwitchRedundancyMode
Data Type: Integer
Possible Data Values

Meaning of Data Value

nonRedundant(1)

The AC power switch is not expecting redundancy.

redundant(2)

The AC power switch is expecting redundancy.

Table 9-13. AC Power Cord State Capabilities
Variable Name: DellACPowerCordStateCapabilities
Data Type: Integer
Possible Data Values

Meaning of Data Value

unknown(1)

The AC power cord’s capabilities are unknown.

onlineCapable(2)

The AC power cord can be disabled (offline) or
enabled (online).

notReadyCapable(4)

The AC power cord’s capabilities are not ready.

Table 9-14. AC Power Cord State Settings
Variable Name: DellACPowerCordStateSettings
Data Type: Integer
Possible Data Values

Meaning of Data Value

unknown(1)

The AC power cord’s state is unknown.

online(2)

The AC power cord’s state is disabled (offline) 0 or
enabled (online) 1.

notReady(4)

The AC power cord’s state is not ready.

acPowerCordHasPower The AC power cord has power.
(8)
acPowerCordIsActive The AC power cord is the active source of
Source(16)
AC power.

196

Power Group

Table 9-15.

Battery Reading

Variable Name: DellBatteryReading
Data Type: Integer

NOTE: These values are bit masks, so combination values are possible.
Possible Data Values

Meaning of Data Value

predictiveFailure(1)

Battery sensor detects predictive failure.

failed(2)

Battery has failed.

presenceDetected(4)

Battery presence is detected.

Table 9-16.

Power Cap Capabilities

Variable Name: DellPowerCapCapabilities
Data Type: Integer

NOTE: These values are bit masks, so combination values are possible.
Possible Data Values

Meaning of Data Value

none(0)

No power cap capabilities are available.

enable(1)

Power cap can be enabled.

disable(2)

Power cap can be disabled.

Table 9-17.

Power Cap Setting

Variable Name: DellPowerCapSetting
Data Type: Integer
Possible Data Values

Meaning of Data Value

disabled(0)

Power cap is disabled.

enabled(1)

Power cap is enabled.

Power Group

197

Table 9-18. Power Profile Type
Variable Name: DellPowerProfileType
Data Type: Integer

NOTE: These values are bit masks, so combination values are possible.
Possible Data Values

Meaning of Data Value

maxPerformance(1)

Power profile type is Maximum Performance.

osControl(2)

Power profile type is OS control.

activePowerController(4) Power profile type is Active Power Controller.
custom(8)

Power profile type is Custom.

Table 9-19. CPU Power Performance Management Type
Variable Name: DellCPUPowerPerformanceManagementType
Data Type: Integer

NOTE: These values are bit masks, so combination values are possible.
Possible Data Values

Meaning of Data Value

maxPerformance(1)

CPU power and performance management type is
Maximum Performance.

minPower(2)

CPU power and performance management type is
Minimum Power.

osDBPM(4)

CPU power and performance management type is
OS Demand Based Power Management.

systemDBPM(8)

CPU power and performance management type is
System Demand Based Power Management.

198

Power Group

Table 9-20.

Memory Power Performance Management Type

Variable Name: DellMemoryPowerPerformanceManagementType
Data Type: Integer

NOTE: These values are bit masks, so combination values are possible.
Possible Data Values

Meaning of Data Value

maxPerformance(1)

Memory power and performance management
type is Maximum Performance.

mhz1333(2)

Memory power and performance is 1333 MHz.

mhz1067(4)

Memory power and performance is 1067 MHz.

mhz800(8)

Memory power and performance is 800 MHz.

minPower(16)

Memory power and performance management
type is Minimum Power.

Table 9-21.

Fan Power Performance Management Type

Variable Name: DellFanPowerPerformanceManagementType
Data Type: Integer

NOTE: These values are bit masks, so combination values are possible.
Possible Data Values

Meaning of Data Value

maxPerformance(1)

Fan power and performance management type is
Maximum Performance.

minPower(2)

Fan power and performance management type is
Minimum Power.

Power Group

199

200

Power Group

10

Thermal Group

The Thermal Group provides information about cooling units, cooling
devices, and temperature probes. Cooling units are sets of fans or other
cooling devices in a system chassis. Thermal Group variables include
threshold values and types of cooling devices and temperature probes.

Thermal Group Tables
The following management information base (MIB) tables define the objects
in the Thermal Group:
•

"Cooling Unit Table" on page 201

•

"Cooling Unit Status" on page 203

•

"Temperature Probe Table" on page 209

Cooling Unit Table
Name

coolingUnitTable

Object ID

1.3.6.1.4.1.674.10892.1.700.10

Description

Defines the Cooling Unit Table.

Syntax

TableEntry

Access

Not accessible

Cooling Unit Table Entry
Name

coolingUnitTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.700.10.1

Description

Defines the Cooling Unit Table entry.

Syntax

TableEntry

Access

Not accessible

Index

coolingUnitchassisIndex, coolingUnitIndex

Thermal Group

201

Cooling Unit Chassis Index
Name

coolingUnitchassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.700.10.1.1

Description

Defines the index (one-based) of this chassis.

Syntax

TableEntry

Access

Read-only

Cooling Unit Index
Name

coolingUnitIndex

Object ID

1.3.6.1.4.1.674.10892.1.700.10.1.2

Description

Defines the index (one-based) of cooling units.

Syntax

DellObjectRange

Access

Read-only

Cooling Unit State Capabilities
Name

coolingUnitStateCapabilties

Object ID

1.3.6.1.4.1.674.10892.1.700.10.1.3

Description

Defines the capabilities of the cooling unit.

Syntax

DellStateCapabilities

Access

Read-only

Cooling Unit State Settings
Name

coolingUnitStateSettings

Object ID

1.3.6.1.4.1.674.10892.1.700.10.1.4

Description

Defines the state and settings of the cooling unit.

Syntax

DellStateSettings

Access

Read-write

202

Thermal Group

Cooling Unit Redundancy Status
Name

coolingUnitRedundancyStatus

Object ID

1.3.6.1.4.1.674.10892.1.700.10.1.5

Description

Defines the redundancy status of the cooling unit.

Syntax

DellStatusRedundancy

Access

Read-only

Cooling Device Count For Redundancy
Name

coolingDeviceCountForRedundancy

Object ID

1.3.6.1.4.1.674.10892.1.700.10.1.6

Description

Defines the total number of cooling devices required for this
cooling unit to have redundancy.

Syntax

DellObjectRange

Access

Read-only

Cooling Unit Name
Name

coolingUnitName

Object ID

1.3.6.1.4.1.674.10892.1.700.10.1.7

Description

Defines the cooling unit name in this chassis.

Syntax

DellString

Access

Read-only

Cooling Unit Status
Name

coolingUnitStatus

Object ID

1.3.6.1.4.1.674.10892.1.700.10.1.8

Description

Defines the status of the cooling unit in this chassis.

Syntax

DellStatus

Access

Read-only

Thermal Group

203

Cooling Device Table
Name

coolingDeviceTable

Object ID

1.3.6.1.4.1.674.10892.1.700.12

Description

Defines the Cooling Device Table.

Syntax

CoolingDeviceTableEntry

Access

Not accessible

Cooling Device Table Entry
Name

coolingDeviceTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.700.12.1

Description

Defines the Cooling Device Table entry.

Syntax

CoolingDeviceTableEntry

Access

Not accessible

Index

cooling DevicechassisIndex, coolingDeviceIndex

Cooling Device Chassis Index
Name

coolingDevicechassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.700.12.1.1

Description

Defines the index (one-based) of this chassis.

Syntax

DellObjectRange

Access

Read-only

Cooling Device Index
Name

coolingDeviceIndex

Object ID

1.3.6.1.4.1.674.10892.1.700.12.1.2

Description

Defines the index of cooling devices in this chassis.

Syntax

DellObjectRange

Access

Read-only

204

Thermal Group

Cooling Device State Capabilities
Name

coolingDeviceStateCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.700.12.1.3

Description

Defines the capabilities of the cooling device.

Syntax

DellStateCapabilities

Access

Read-only

Cooling Device State Settings
Name

coolingDeviceStateSettings

Object ID

1.3.6.1.4.1.674.10892.1.700.12.1.4

Description

Defines the state and settings of the cooling device.

Syntax

DellStateSettings

Access

Read-write

Cooling Device Status
Name

coolingDeviceStatus

Object ID

1.3.6.1.4.1.674.10892.1.700.12.1.5

Description

Defines the status of the cooling device.

Syntax

DellStatusProbe

Access

Read-only

Thermal Group

205

Cooling Device Reading
Name

coolingDeviceReading

Object ID

1.3.6.1.4.1.674.10892.1.700.12.1.6

Description

Defines either the cooling device’s speed in revolutions
per minute (RPM), or the off/on value of the fan.
When the value for coolingDeviceSubType is other than
coolingDeviceSubTypeIsDiscrete, the value returned for this
attribute is the speed in RPM or the OFF/ON value of the cooling
device. When the value for coolingDeviceSubType is
coolingDeviceSubTypeIsDiscrete, a value is not returned for
this attribute.

Syntax

DellSigned32BitRange

Access

Read-only

Cooling Device Type
Name

coolingDeviceType

Object ID

1.3.6.1.4.1.674.10892.1.700.12.1.7

Description

Defines the cooling device type.

Syntax

DellCoolingDeviceType (See Table 10-1)

Access

Read-only

Cooling Device Location Name
Name

coolingDeviceLocationName

Object ID

1.3.6.1.4.1.674.10892.1.700.12.1.8

Description

Defines the location of the cooling device in this chassis.

Syntax

DellString

Access

Read-only

206

Thermal Group

Cooling Device Upper Nonrecoverable Threshold
Name

coolingDeviceUppernonrecoverableThreshold

Object ID

1.3.6.1.4.1.674.10892.1.700.12.1.9

Description

Defines the value of the fan’s upper nonrecoverable threshold.

Syntax

DellSigned32BitRange

Access

Read-only

Cooling Device Upper Critical Threshold
Name

coolingDeviceUpperCriticalThreshold

Object ID

1.3.6.1.4.1.674.10892.1.700.12.1.10

Description

Defines the value of the fan’s upper critical threshold.

Syntax

DellSigned32BitRange

Access

Read-only

Cooling Device Upper Noncritical Threshold
Name

coolingDeviceUpperNonCriticalThreshold

Object ID

1.3.6.1.4.1.674.10892.1.700.12.1.11

Description

Defines the user-assigned value of the fan’s upper noncritical
threshold.

Syntax

DellSigned32BitRange

Access

Read-write

Cooling Device Lower Noncritical Threshold
Name

coolingDeviceLowerNonCriticalThreshold

Object ID

1.3.6.1.4.1.674.10892.1.700.12.1.12

Description

Defines the user-assigned value of the fan’s lower noncritical
threshold.

Syntax

DellSigned32BitRange

Access

Read-write

Thermal Group

207

Cooling Device Lower Critical Threshold
Name

coolingDeviceLowerCriticalThreshold

Object ID

1.3.6.1.4.1.674.10892.1.700.12.1.13

Description

Defines the value of the fan’s lower critical threshold.

Syntax

DellSigned32BitRange

Access

Read-only

Cooling Device Lower Nonrecoverable Threshold
Name

coolingDeviceLowerNonRecoverableThreshold

Object ID

1.3.6.1.4.1.674.10892.1.700.12.1.14

Description

Defines the value of the fan’s lower nonrecoverable threshold.

Syntax

DellSigned32BitRange

Access

Read-only

Cooling Device Cooling Unit Index Reference
Name

coolingDevicecoolingUnitIndexReference

Object ID

1.3.6.1.4.1.674.10892.1.700.12.1.15

Description

Defines the index for the associated system cooling unit in this
chassis.

Syntax

DellObjectRange

Access

Read-only

Cooling Device Subtype
Name

coolingDeviceSubType

Object ID

1.3.6.1.4.1.674.10892.1.700.12.1.16

Description

Defines the cooling device subtype.

Syntax

DellCoolingDeviceSubType (See Table 10-2)

Access

Read-only

208

Thermal Group

Cooling Device Probe Capabilities
Name

coolingDeviceProbeCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.700.12.1.17

Description

Defines the probe capabilities of the cooling device.

Syntax

DellProbeCapabilities

Access

Read-only

Cooling Device Discrete Reading
Name

coolingDeviceDiscreteReading

Object ID

1.3.6.1.4.1.674.10892.1.700.12.1.18

Description

Defines the reading for a voltage probe of type
coolingDeviceSubTypeIsDiscrete.
When the value for coolingDeviceSubType is other than
coolingDeviceSubTypeIsDiscrete, a value is not returned for this
attribute. When the value for coolingDeviceSubType is
coolingDeviceSubTypeIsDiscrete, the value returned for this
attribute is the discrete reading for the cooling device.

Syntax

DellCoolingDeviceDiscreteReading (See Table 10-3)

Access

Read-only

Temperature Probe Table
Name

temperatureProbeTable

Object ID

1.3.6.1.4.1.674.10892.1.700.20

Description

Defines the Temperature Probe Table.

Syntax

TemperatureProbeTableEntry

Access

Not accessible

Thermal Group

209

Temperature Probe Table Entry
Name

temperatureProbeTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.700.20.1

Description

Defines the Temperature Probe Table entry.

Syntax

TemperatureProbeTableEntry

Access

Not accessible

Index

temperatureProbechassisIndex,
temperatureProbeIndex

Temperature Probe Chassis Index
Name

temperatureProbechassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.700.20.1.1

Description

Defines the index (one-based) of this chassis.

Syntax

DellObjectRange

Access

Read-only

Temperature Probe Index
Name

temperatureProbeIndex

Object ID

1.3.6.1.4.1.674.10892.1.700.20.1.2

Description

Defines the index of temperature probes in this chassis.

Syntax

DellObjectRange

Access

Read-only

Temperature Probe State Capabilities
Name

temperatureProbeStateCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.700.20.1.3

Description

Defines the capabilities of the temperature probe.

Syntax

DellStateCapabilities

Access

Read-only

210

Thermal Group

Temperature Probe State Settings
Name

temperatureProbeStateSettings

Object ID

1.3.6.1.4.1.674.10892.1.700.20.1.4

Description

Defines the state and settings of the temperature probe.

Syntax

DellStateSettings

Access

Read-write

Temperature Probe Status
Name

temperatureProbeStatus

Object ID

1.3.6.1.4.1.674.10892.1.700.20.1.5

Description

Defines the status of the temperature probe in tenths of degrees
Celsius.

Syntax

DellStatusProbe

Access

Read-only

Temperature Probe Reading
Name

temperatureProbeReading

Object ID

1.3.6.1.4.1.674.10892.1.700.20.1.6

Description

Defines the value of the temperature probe.
When the value for temperatureProbeType is other than
temperatureProbeTypeIsDiscrete, the value returned for this
attribute is the temperature that the probe is reading in tenths
of degrees Centigrade. When the value for
temperatureProbeType is temperatureProbeTypeIsDiscrete,
a value is not returned for this attribute.

Syntax

DellSigned32BitRange

Access

Read-only

Thermal Group

211

Temperature Probe Type
Name

temperatureProbeType

Object ID

1.3.6.1.4.1.674.10892.1.700.20.1.7

Description

Defines the temperature probe type.

Syntax

DellTemperatureProbeType (See Table 10-4)

Access

Read-only

Temperature Probe Location Name
Name

temperatureProbeLocationName

Object ID

1.3.6.1.4.1.674.10892.1.700.20.1.8

Description

Defines the location of the temperature probe in this chassis.

Syntax

DellString

Access

Read-only

Temperature Probe Upper Nonrecoverable Threshold
Name

temperatureProbeUpperNonRecoverableThreshold

Object ID

1.3.6.1.4.1.674.10892.1.700.20.1.9

Description

Defines the value of the temperature probe’s upper
nonrecoverable threshold.

Syntax

DellSigned32BitRange

Access

Read-only

Temperature Probe Upper Critical Threshold
Name

temperatureProbeUpperCriticalThreshold

Object ID

1.3.6.1.4.1.674.10892.1.700.20.1.10

Description

Defines the value of the temperature probe’s upper critical
threshold.

Syntax

DellSigned32BitRange

Access

Read-only

212

Thermal Group

Temperature Probe Upper Noncritical Threshold
Name

temperatureProbeUpperNonCriticalThreshold

Object ID

1.3.6.1.4.1.674.10892.1.700.20.1.11

Description

Defines the user-assigned value of the temperature probe’s
upper noncritical threshold.

Syntax

DellSigned32BitRange

Access

Read-write

Temperature Probe Lower Noncritical Threshold
Name

temperatureProbeLowerNonCriticalThreshold

Object ID

1.3.6.1.4.1.674.10892.1.700.20.1.12

Description

Defines the user-assigned value of the temperature probe’s
lower noncritical threshold.

Syntax

DellSigned32BitRange

Access

Read-write

Temperature Probe Lower Critical Threshold
Name

temperatureProbeLowerCriticalThreshold

Object ID

1.3.6.1.4.1.674.10892.1.700.20.1.13

Description

Defines the value of the temperature probe’s lower critical threshold.

Syntax

DellSigned32BitRange

Access

Read-only

Temperature Probe Lower Nonrecoverable Threshold
Name

temperatureProbeLowerNonRecoverableThreshold

Object ID

1.3.6.1.4.1.674.10892.1.700.20.1.14

Description

Defines the value of the temperature probe’s lower
nonrecoverable threshold.

Syntax

DellSigned32BitRange

Access

Read-only
Thermal Group

213

Temperature Probe Probe Capabilities
Name

temperatureProbeProbeCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.700.20.1.15

Description

Defines the probe capabilities of the temperature probe.

Syntax

DellProbeCapabilities

Access

Read-only

Temperature Probe Discrete Reading
Name

temperatureProbeDiscreteReading

Object ID

1.3.6.1.4.1.674.10892.1.700.20.1.16

Description

Defines the reading for a temperature probe of type
temperatureProbeTypeIsDiscrete.
When the value for temperatureProbeType is other than
temperatureProbeTypeIsDiscrete, a value is not returned for this
attribute. When the value for temperatureProbeType is
temperatureProbeTypeIsDiscrete, the value returned for this
attribute is the discrete reading for the probe.

Syntax

DellTemperatureDiscreteReading (See Table 10-5)

Access

Read-only

214

Thermal Group

Thermal Group Variable Values
This section includes definitions for server administrator-specific variable
values used in this section.
Table 10-1.

Cooling Device Type

Variable Name: DellCoolingDeviceType
Data Type: Integer
Possible Data Values

Meaning of Data Value

coolingDeviceTypeIsOther(1)

The cooling device type is not
one of the following:

coolingDeviceTypeIsUnknown(2)

The cooling device type is
unknown (not known or not
monitored).

coolingDeviceTypeIsAFan(3)

The cooling device type is
a fan.

coolingDeviceTypeIsABlower(4)

The cooling device type is a
centrifugal blower.

coolingDeviceTypeIsAChipFan(5)

The cooling device type is a
fan on an integrated circuit.

coolingDeviceTypeIsACabinetFan(6)

The cooling device type is a
cabinet fan.

coolingDeviceTypeIsAPowerSupplyFan(7) The cooling device type is a
power supply fan.
coolingDeviceTypeIsAHeatPipe(8)

The cooling device type is a
heat pipe.

coolingDeviceTypeIsRefrigeration(9)

The cooling device type is an
integrated refrigeration unit.

coolingDeviceTypeIsActiveCooling(10)

The cooling device type is an
active cooling device.

coolingDeviceTypeIsPassiveCooling(11) The cooling device type is a
passive cooling device.

Thermal Group

215

Table 10-2. Cooling Device Subtype
Variable Name: DellCoolingDeviceSubType
Data Type: Integer
Possible Data Values

Meaning of Data Value

coolingDeviceSubTypeIsOther(1)

The cooling device subtype is
not one of the following:

coolingDeviceSubTypeIsUnknown(2)

The cooling device subtype is
unknown (not known or
not monitored).

coolingDeviceSubTypeIsAFanThatReads The cooling device subtype is a
InRPM(3)
fan that reads in RPMs.
coolingDeviceSubTypeIsAFanReadsONor The cooling device subtype is a
OFF(4)
fan that reads 0 (off) or 1 (on).
coolingDeviceSubTypeIsAPowerSupply The cooling device subtype is a
FanThatReadsinRPM(5)
power supply fan that reads in
RPMs.
coolingDeviceSubTypeIsAPowerSupply The cooling device subtype is a
FanThatReads- ONorOFF(6)
power supply fan that
reads 0 (off) or 1 (on).
coolingDeviceSubTypeIsDiscrete(16)

The cooling device subtype is a
cooling device with
discrete reading.

Table 10-3. Cooling Device Discrete Reading
Variable Name: DellCoolingDeviceDiscreteReading
Data Type: Integer
Possible Data Values

Meaning of Data Value

coolingDeviceIsGood(1)

The cooling device discrete reading is good.

coolingDeviceIsBad(2)

The cooling device discrete reading is bad.

216

Thermal Group

Table 10-4.

Temperature Probe Type

Variable Name: DellTemperatureProbeType
Data Type: Integer
Possible Data Values

Meaning of Data Value

temperatureProbeTypeIsOther(1)

The temperature probe subtype
is not one of the following:

temperatureProbeTypeIsUnknown(2)

The temperature probe subtype
is unknown (not known or not
monitored).

temperatureProbeTypeIsAmbientESM(3) The temperature probe is for
ambient Embedded Systems
Management (ESM).
temperatureProbeTypeIsDiscrete(16)

Table 10-5.

The temperature probe subtype
is a temperature probe with
discrete reading.

Temperature Probe Discrete Reading

Variable Name: DellTemperatureDiscreteReading
Data Type: Integer
Possible Data Values

Meaning of Data Value

temperatureIsGood(1)

The temperature probe discrete reading is good.

temperatureIsBad(2)

The temperature probe discrete reading is bad.

Thermal Group

217

218

Thermal Group

11

User Security Group

The User Security Table defines the objects that allow administrators to
create and modify user accounts and to control which users can perform Set
operations on managed systems.

User Security Group Table
The User Security Group defines objects in the User Security MIB table.

User Security Table
The following object sets up the User Security Table:
Name

userSecurityTable

Object ID

1.3.6.1.4.1.674.10892.1.800

Description

Contains the database of users that are authorized to perform
Set operations on a managed system.

Syntax

UserSecurityTableEntry

Access

Not accessible

User Security Table Entry
Name

userSecurityTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.800.1

Description

Defines a row in the User Security Table.

Syntax

UserSecurityTableEntry

Access

Not accessible

Index

userSecuritychassisIndex, userSecurityIndex

User Security Group

219

User Security Chassis Index
Name

userSecuritychassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.800.1.1

Description

Defines the user security index (one-based) of this chassis.

Syntax

DellObjectRange

Access

Read-only

User Security Index
Name

userSecurityIndex

Object ID

1.3.6.1.4.1.674.10892.1.800.1.2

Description

Defines the user security index.

Syntax

DellObjectRange

Access

Read-only

User Security User Name
Name

userSecurityUserName

Object ID

1.3.6.1.4.1.674.10892.1.800.1.3

Description

Defines the user security user name.

Syntax

DellSecurityString

Access

Read-only

User Security Control Name
Name

userSecurityControlName

Object ID

1.3.6.1.4.1.674.10892.1.800.1.4

Description

Defines a control name used for creating, deleting, and editing
users.

Syntax

DellSecurityString

Access

Read-write

220

User Security Group

User Security Request Name
Name

userSecurityRequestName

Object ID

1.3.6.1.4.1.674.10892.1.800.1.5

Description

Defines a request name used for creating, deleting, and editing
users.

Syntax

DellSecurityString

Access

Read-write

User Security Group

221

222

User Security Group

Remote Flash BIOS Group

12

The Remote Flash Basic Input/Output System (BIOS) Table defines the
variables used to remotely update the BIOS in a system. The variables also
define the capabilities of BIOS updates on the system.

Remote Flash BIOS Group Table
The Remote Flash BIOS Group defines objects in the Remote Flash BIOS
MIB table.

Remote Flash BIOS Table
The following object sets up the Remote Flash BIOS Table:
Name

remoteFlashBIOSTable

Object ID

1.3.6.1.4.1.674.10892.1.900.10

Description

Defines the Remote Flash BIOS Table.

Syntax

RemoteFlashBIOSTableEntry

Access

Not accessible

Remote Flash BIOS Table Entry
Name

remoteFlashBIOSTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.900.10.1

Description

Defines the Remote Flash BIOS Table entry.

Syntax

RemoteFlashBIOSTableEntry

Access

Not accessible

Index

remoteFlashBIOSchassisIndex, remoteFlashBIOSIndex

Remote Flash BIOS Group

223

Remote Flash BIOS Chassis Index
Name

remoteFlashBIOSchassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.900.10.1.1

Description

Defines the index (one-based) of this chassis.

Syntax

DellObjectRange

Access

Read-only

Remote Flash BIOS Index
Name

remoteFlashBIOSIndex

Object ID

1.3.6.1.4.1.674.10892.1.900.10.1.2

Description

Defines the index to the remote BIOS update hardware on this
system.

Syntax

DellObjectRange

Access

Read-only

Remote Flash BIOS State Capabilities Unique
Name

remoteFlashBIOSStateCapabilitiesUnique

Object ID

1.3.6.1.4.1.674.10892.1.900.10.1.3

Description

Defines the capabilities of the remote BIOS update hardware on
this system.

Syntax

DellRemoteFlashBIOSStateCapabilitiesUnique (See Table 12-1)

Access

Read-only

Remote Flash BIOS State Settings Unique
Name

remoteFlashBIOSStateSettingsUnique

Object ID

1.3.6.1.4.1.674.10892.1.900.10.1.4

Description

Defines the state and settings of the remote BIOS update
hardware on this system.

Syntax

DellRemoteFlashBIOSStateSettingsUnique (See Table 12-2)

Access

Read-write

224

Remote Flash BIOS Group

Remote Flash BIOS Status
Name

remoteFlashBIOSStatus

Object ID

1.3.6.1.4.1.674.10892.1.900.10.1.5

Description

Defines the status of the remote BIOS update hardware on
this system.

Syntax

DellRemoteFlashBIOSStateStatus

Access

Read-only

Remote Flash BIOS Last BIOS Date Name
Name

remoteFlashBIOSLastBIOSDateName

Object ID

1.3.6.1.4.1.674.10892.1.900.10.1.6

Description

Defines the date of the last BIOS update.

Syntax

DellDateName

Access

Read-only

Remote Flash BIOS Completion Code
Name

remoteFlashBIOSCompletionCode

Object ID

1.3.6.1.4.1.674.10892.1.900.10.1.7

Description

Defines the completion code of the last BIOS update.

Syntax

DellRemoteFlashBIOSCompletionCode (See Table 12-3 on
page 227)

Access

Read-only

Remote Flash BIOS Minimum Contiguous Memory
Name

remoteFlashBIOSMinimumContiguousMemory

Object ID

1.3.6.1.4.1.674.10892.1.900.10.1.8

Description

Defines the minimum size of contiguous memory required for
remote BIOS update in kilobytes.

Syntax

DellUnsigned32BitRange

Access

Read-only
Remote Flash BIOS Group

225

Remote Flash BIOS Variable Values
This section includes definitions for server administrator-specific variable
values used in this section.
Table 12-1. Remote Flash BIOS State Capabilities Unique
Variable Name: DellRemoteFlashBIOSStateCapabilitiesUnique
Data Type: Integer
Possible Data Values

Meaning of Data Value

unknown(1)

The remote flash BIOS’s capabilities are
unknown.

enableCapable(2)

The remote flash BIOS can be disabled
(offline, a binary 0 value) or enabled (online,
a binary 1 value).

notReadyCapable(4)

The remote flash BIOS can be set to
indicate not ready.

cancelCapable(8)

Flash of BIOS can be canceled.

enableAndCancelCapable(10) Flash of BIOS can be enabled or canceled.
Table 12-2. Remote Flash BIOS State Settings
Variable Name: DellRemoteFlashBIOSStateSettingsUnique
Data Type: Integer
Possible Data Values

Meaning of Data Value

unknown(1)

The remote flash BIOS’s capabilities are unknown.

enabled(2)

The remote flash BIOS update is disabled (offline, a
binary 0 value) or enabled (online, a binary 1 value).

notReady(4)

The remote flash BIOS’s state is not ready.

canceled(8)

The remote flash BIOS has been canceled.

pending(16)

The remote flash BIOS update is pending.

other(32)

The remote flash BIOS state/setting is not one of
the previous values.

226

Remote Flash BIOS Group

Table 12-3.

Remote Flash BIOS Completion Code

Variable Name: DellRemoteFlashBIOSCompletionCode
Data Type: Integer
Possible Data Values

Meaning of Data Value

completionCodeIsOther(1)

The completion code status is
not one of the following:

completionCodeIsUnknown(2)

The completion code is unknown
(not known or not monitored).

completionCodeIsOK(3)

This completion code completed
successfully.

completionCodeIsBadImage(4)

This completion code is a bad
flash BIOS image.

completionCodeIsNoFileAccess(5)

Flash BIOS could not be
accessed.

completionCodeIsNotReady(6)

Flash BIOS memory not ready.

completionCodeIsDisabled(7)

Flash BIOS is currently disabled.

completionCodeIsNoBattery(8)

A battery must be installed.

completionCodeIsNoChargedBattery(9) A fully charged battery must be
installed.
completionCodeIsNoExternalPower(10) An external power adapter must
be connected.
12 volts (V) could not be set.

completionCodeIsNo12VoltSet(11)

completionCodeIsNo12VoltRemoval(12) 12 V could not be removed.
completionCodeIsFlashMemoryFailed
(13)

A flash memory failure occurred.

completionCodeIsGeneralFailure(14) A general failure occurred.
completionCodeIsDataMiscompare(15) A data miscompare error
occurred.
completionCodeIsNoImageFound(16)

The flash BIOS image could not
be found in memory.

completionCodeIsNoUpdatePerformed
(17)

No update operation has been
performed.

Remote Flash BIOS Group

227

228

Remote Flash BIOS Group

13

Port Group

The Port Group provides information about the different types of ports that
may be present in your system. This management information base (MIB)
group also provides information about the capabilities, states, and settings
that are possible for each port.

Port Group Tables
The following MIB tables define objects in the Port Group:
•

"Pointing Port Table" on page 229

•

"Keyboard Port Table" on page 232

•

"Processor Port Table" on page 235

•

"Memory Device Port Table" on page 238

•

"Monitor Port Table" on page 241

•

"Small Computer System Interface (SCSI) Port Table" on page 244

•

"Parallel Port Table" on page 246

•

"Serial Port Table" on page 250

•

"Universal Serial Bus (USB) Port Table" on page 254

Pointing Port Table
Name

pointingPortTable

Object ID

1.3.6.1.4.1.674.10892.1.1000.10

Description

Defines the Pointing Port Table.

Syntax

IntegerPointingPortTableEntry

Access

Not accessible

Port Group

229

Pointing Port Table Entry
Name

pointingPortTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.1000.10.1

Description

Defines the Pointing Port Table entry.

Syntax

PointingPortTableEntry

Access

Not accessible

Index

pointingPortchassisIndex, pointingPortIndex

Pointing Port Chassis Index
Name

pointingPortchassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.1000.10.1.1

Description

Defines the index (one-based) of this chassis.

Syntax

DellObjectRange

Access

Read-only

Pointing Port Index
Name

pointingPortIndex

Object ID

1.3.6.1.4.1.674.10892.1.1000.10.1.2

Description

Defines the index of the pointing ports in this chassis.

Syntax

DellObjectRange

Access

Read-only

Pointing Port State Capabilities
Name

pointingPortStateCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.1000.10.3

Description

Defines the capabilities of the pointing port.

Syntax

DellStateCapabilities

Access

Read-only

230

Port Group

Pointing Port State Settings
Name

pointingPortStateSettings

Object ID

1.3.6.1.4.1.674.10892.1.1000.10.4

Description

Defines the state and settings of the pointing port.

Syntax

DellStateSettings

Access

Read-write

Pointing Port Status
Name

pointingPortStatus

Object ID

1.3.6.1.4.1.674.10892.1.1000.10.5

Description

Defines the status of the pointing port.

Syntax

DellStatus

Access

Read-only

Pointing Port Security State
Name

pointingPortSecurityState

Object ID

1.3.6.1.4.1.674.10892.1.1000.10.6

Description

Defines the security settings of the pointing port.

Syntax

DellPortSecurityState

Access

Read-only

Pointing Port Connector Type
Name

pointingPortConnectorType

Object ID

1.3.6.1.4.1.674.10892.1.1000.10.7

Description

Defines the connector type of the pointing port.

Syntax

DellPointingPortConnectorType (See Table 13-1)

Access

Read-only

Port Group

231

Pointing Port Name
Name

pointingPortName

Object ID

1.3.6.1.4.1.674.10892.1.1000.10.8

Description

Defines the name of the pointing port.

Syntax

DellString

Access

Read-only

Pointing Port BIOS Connector Type
Name

pointingPortBIOSConnectorType

Object ID

1.3.6.1.4.1.674.10892.1.1000.10.9

Description

Defines the basic input/output system (BIOS) connector type of
the pointing port.

Syntax

DellGenericPortConnectorType

Access

Read-only

Keyboard Port Table
Name

keyboardPortTable

Object ID

1.3.6.1.4.1.674.10892.1.1000.20

Description

Defines the Keyboard Port Table.

Syntax

IntegerKeyboardPortTableEntry

Access

Not accessible

Keyboard Port Table Entry
Name

keyboardPortTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.1000.20.1

Description

Defines the Keyboard Port Table entry.

Syntax

KeyboardPortTableEntry

Access

Not accessible

Index

keyboardPortchassisIndex, keyboardPortIndex

232

Port Group

Keyboard Port Chassis Index
Name

keyboardPortchassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.1000.20.1.1

Description

Defines the index (one-based) of this chassis.

Syntax

DellObjectRange

Access

Read-only

Keyboard Port Index
Name

keyboardPortIndex

Object ID

1.3.6.1.4.1.674.10892.1.1000.20.1.2

Description

Defines the index of the keyboard ports in this chassis.

Syntax

DellObjectRange

Access

Read-only

Keyboard Port State Capabilities
Name

keyboardPortStateCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.1000.20.1.3

Description

Defines the capabilities of the keyboard port.

Syntax

DellStateCapabilities

Access

Read-only

Keyboard Port State Settings
Name

keyboardPortStateSettings

Object ID

1.3.6.1.4.1.674.10892.1.1000.20.1.4

Description

Defines the state and settings of the keyboard port.

Syntax

DellStateSettings

Access

Read-only

Port Group

233

Keyboard Port Status
Name

keyboardPortStatus

Object ID

1.3.6.1.4.1.674.10892.1.1000.20.1.5

Description

Defines the status of the keyboard port.

Syntax

DellStatus

Access

Read-only

Keyboard Port Security State
Name

keyboardPortSecurityState

Object ID

1.3.6.1.4.1.674.10892.1.1000.20.1.6

Description

Defines the security settings of the keyboard port.

Syntax

DellPortSecurityState

Access

Read-only

Keyboard Port Connector Type
Name

keyboardPortConnectorType

Object ID

1.3.6.1.4.1.674.10892.1.1000.20.1.7

Description

Defines the connector type of the keyboard port.

Syntax

DellKeyboardPortConnectorType (See Table 13-2)

Access

Read-only

Keyboard Port Name
Name

keyboardPortName

Object ID

1.3.6.1.4.1.674.10892.1.1000.20.1.8

Description

Defines the name of the keyboard port.

Syntax

DellString

Access

Read-only

234

Port Group

Keyboard Port BIOS Connector Type
Name

keyboardPortBIOSConnectorType

Object ID

1.3.6.1.4.1.674.10892.1.1000.20.1.9

Description

Defines the BIOS connector type of the keyboard port.

Syntax

DellGenericPortConnectorType

Access

Read-only

Processor Port Table
Name

processorPortTable

Object ID

1.3.6.1.4.1.674.10892.1.1000.30

Description

Defines the Processor Port Table.

Syntax

IntegerProcessorPortTableEntry

Access

Not accessible

Processor Port Table Entry
Name

processorPortTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.1000.30.1

Description

Defines the Processor Port Table entry.

Syntax

ProcessorPortTableEntry

Access

Not accessible

Index

processorPortchassisIndex, processorPortIndex

Processor Port Chassis Index
Name

processorPortchassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.1000.30.1.1

Description

Defines the index (one-based) of this chassis.

Syntax

DellObjectRange

Access

Read-only

Port Group

235

Processor Port Index
Name

processorPortIndex

Object ID

1.3.6.1.4.1.674.10892.1.1000.30.1.2

Description

Defines the index of the processor ports in this chassis.

Syntax

DellObjectRange

Access

Read-only

Processor Port State Capabilities
Name

processorPortStateCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.1000.30.1.3

Description

Defines the capabilities of the processor port.

Syntax

DellStateCapabilities

Access

Read-only

Processor Port State Settings
Name

processorPortStateSettings

Object ID

1.3.6.1.4.1.674.10892.1.1000.30.1.4

Description

Defines the state and settings of the processor port.

Syntax

DellStateSettings

Access

Read-write

Processor Port Status
Name

processorPortStatus

Object ID

1.3.6.1.4.1.674.10892.1.1000.30.1.5

Description

Defines the status of the processor port.

Syntax

DellStatus

Access

Read-only

236

Port Group

Processor Port Security State
Name

processorPortSecurityState

Object ID

1.3.6.1.4.1.674.10892.1.1000.30.1.6

Description

Defines the security settings of the processor port.

Syntax

DellPortSecurityState

Access

Read-only

Processor Port Connector Type
Name

processorPortConnectorType

Object ID

1.3.6.1.4.1.674.10892.1.1000.30.1.7

Description

Defines the connector type of the processor port.

Syntax

DellProcessorPortConnectorType (See Table 13-3)

Access

Read-only

Processor Port Name
Name

processorPortName

Object ID

1.3.6.1.4.1.674.10892.1.1000.30.1.8

Description

Defines name of the processor port.

Syntax

DellString

Access

Read-only

Processor Port BIOS Connector Type
Name

processorPortBIOSConnectorType

Object ID

1.3.6.1.4.1.674.10892.1.1000.30.1.9

Description

Defines the BIOS connector type of the processor port.

Syntax

DellGenericPortConnectorType

Access

Read-only

Port Group

237

Memory Device Port Table
Name

memoryDevicePortTable

Object ID

1.3.6.1.4.1.674.10892.1.1000.40

Description

Defines the Memory Device Port Table.

Syntax

IntegerMemoryDevicePortTableEntry

Access

Not accessible

Memory Device Port Table Entry
Name

memoryDevicePortTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.1000.40.1

Description

Defines the Memory Device Port Table entry.

Syntax

MemoryDevicePortTableEntry

Access

Not accessible

Index

memoryDevicePortchassisIndex, memoryDevicePortIndex

Memory Device Port Chassis Index
Name

memoryDevicePortchassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.1000.40.1.1

Description

Defines the index (one-based) of this chassis.

Syntax

DellObjectRange

Access

Read-only

Memory Device Port Index
Name

memoryDevicePortIndex

Object ID

1.3.6.1.4.1.674.10892.1.1000.40.1.2

Description

Defines the index of the memory device port in this chassis.

Syntax

DellObjectRange

Access

Read-only

238

Port Group

Memory Device Port State Capabilities
Name

memoryDevicePortStateCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.1000.40.1.3

Description

Defines the capabilities of the memory device port.

Syntax

DellStateCapabilities

Access

Read-only

Memory Device Port State Settings
Name

memoryDevicePortStateSettings

Object ID

1.3.6.1.4.1.674.10892.1.1000.40.1.4

Description

Defines the state and settings of the memory device port.

Syntax

DellStateSettings

Access

Read-write

Memory Device Port Status
Name

memoryDevicePortStatus

Object ID

1.3.6.1.4.1.674.10892.1.1000.40.1.5

Description

Defines the status of the memory device port.

Syntax

DellStatus

Access

Read-only

Memory Device Port Security State
Name

memoryDevicePortSecurityState

Object ID

1.3.6.1.4.1.674.10892.1.1000.40.1.6

Description

Defines the security settings of the memory device port.

Syntax

DellPortSecurityState

Access

Read-only

Port Group

239

Memory Device Port Connector Type
Name

memoryDevicePortConnectorType

Object ID

1.3.6.1.4.1.674.10892.1.1000.40.1.7

Description

Defines the connector type of the memory device port.

Syntax

DellMemoryDevicePortConnectorType (See Table 13-4)

Access

Read-only

Memory Device Port Name
Name

memoryDevicePortName

Object ID

1.3.6.1.4.1.674.10892.1.1000.40.1.8

Description

Defines the name of the memory device port.

Syntax

DellString

Access

Read-only

Memory Device Port BIOS Connector Type
Name

memoryDevicePortBIOSConnectorType

Object ID

1.3.6.1.4.1.674.10892.1.1000.40.1.9

Description

Defines the BIOS connector type of the memory device port.

Syntax

DellGenericPortConnectorType

Access

Read-only

Memory Device Port Physical Memory Array Index Reference
Name

memoryDevicePortPhysicalMemoryArrayIndexReference

Object ID

1.3.6.1.4.1.674.10892.1.1000.40.1.10

Description

Defines the index to the associated physical memory array.

Syntax

DellUnsigned32BitRange

Access

Read-only

240

Port Group

Memory Device Port Physical Memory Card Index Reference
Name

memoryDevicePortPhysicalMemoryCardIndexReference

Object ID

1.3.6.1.4.1.674.10892.1.1000.40.1.11

Description

Defines the index (one-based) of the Physical Memory Card Table
entry for the physical memory card with the same chassis index that
this memory device port is associated with (if any).

Syntax

DellUnsigned32BitRange

Access

Read-only

Monitor Port Table
Name

monitorPortTable

Object ID

1.3.6.1.4.1.674.10892.1.1000.50

Description

Defines the Monitor Port Table.

Syntax

IntegerMonitorPortTableEntry

Access

Not accessible

Monitor Port Table Entry
Name

monitorPortTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.1000.50.1

Description

Defines the Monitor Port Table entry.

Syntax

MonitorPortTableEntry

Access

Not accessible

Index

monitorPortchassisIndex, monitorPortIndex

Monitor Port Chassis Index
Name

monitorPortchassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.1000.50.1.1

Description

Defines the index (one-based) of this chassis

Syntax

DellObjectRange

Access

Read-only

Port Group

241

Monitor Port Index
Name

monitorPortIndex

Object ID

1.3.6.1.4.1.674.10892.1.1000.50.1.2

Description

Defines the index of the monitor ports in this chassis.

Syntax

DellObjectRange

Access

Read-only

Monitor Port State Capabilities
Name

monitorPortStateCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.1000.50.1.3

Description

Defines the capabilities of the monitor port.

Syntax

DellStateCapabilities

Access

Read-only

Monitor Port State Settings
Name

monitorPortStateSettings

Object ID

1.3.6.1.4.1.674.10892.1.1000.50.1.4

Description

Defines the state of the monitor port.

Syntax

DellStateSettings

Access

Read-write

Monitor Port Status
Name

monitorPortStatus

Object ID

1.3.6.1.4.1.674.10892.1.1000.50.1.5

Description

Defines the status of the monitor port.

Syntax

DellStatus

Access

Read-only

242

Port Group

Monitor Port Security State
Name

monitorPortSecurityState

Object ID

1.3.6.1.4.1.674.10892.1.1000.50.1.6

Description

Defines the security settings of the monitor port.

Syntax

DellPortSecurityState

Access

Read-only

Monitor Port Connector Type
Name

monitorPortConnectorType

Object ID

1.3.6.1.4.1.674.10892.1.1000.50.1.7

Description

Defines the connector type of the monitor port.

Syntax

DellMonitorPortConnectorTypes (See Table 13-5)

Access

Read-only

Monitor Port Name
Name

monitorPortName

Object ID

1.3.6.1.4.1.674.10892.1.1000.50.1.8

Description

Defines the name of the monitor port.

Syntax

DellString

Access

Read-only

Monitor Port BIOS Connector Type
Name

monitorPortBIOSConnectorType

Object ID

1.3.6.1.4.1.674.10892.1.1000.50.1.9

Description

Defines the name of the BIOS connector type of the monitor port.

Syntax

DellGenericPortConnectorType

Access

Read-only

Port Group

243

Small Computer System Interface (SCSI) Port Table
Name

sCSIPortTable

Object ID

1.3.6.1.4.1.674.10892.1.1000.60

Description

Defines the SCSI Port Table.

Syntax

IntegerSCSIPortTableEntry

Access

Not accessible

SCSI Port Table Entry
Name

sCSIPortTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.1000.60.1

Description

Defines the SCSI Port Table entry.

Syntax

SCSIPortTableEntry

Access

Not accessible

Index

sCSIPortchassisIndex, sCSIPortIndex

SCSI Port Chassis Index
Name

sCSIPortchassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.1000.60.1.1

Description

Defines the index (one-based) of this chassis

Syntax

DellObjectRange

Access

Read-only

SCSI Port Index
Name

sCSIPortIndex

Object ID

1.3.6.1.4.1.674.10892.1.1000.60.1.2

Description

Defines the index of the SCSI ports in this chassis.

Syntax

DellObjectRange

Access

Read-only

244

Port Group

SCSI Port State Capabilities
Name

sCSIPortStateCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.1000.60.1.3

Description

Defines the capabilities of the SCSI port.

Syntax

DellStateCapabilities

Access

Read-only

SCSI Port State Settings
Name

DellStateSettings

Object ID

1.3.6.1.4.1.674.10892.1.1000.60.1.4

Description

Defines the state and settings of the SCSI port.

Syntax

DellStatus

Access

Read-write

SCSI Port Status
Name

sCSIPortStatus

Object ID

1.3.6.1.4.1.674.10892.1.1000.60.1.5

Description

Defines the status of the SCSI port.

Syntax

DellStatus

Access

Read-only

SCSI Port Security State
Name

sCSIPortSecurityState

Object ID

1.3.6.1.4.1.674.10892.1.1000.60.1.6

Description

Defines the security settings of the SCSI port.

Syntax

DellPortSecurityState

Access

Read-only

Port Group

245

SCSI Port Connector Type
Name

sCSIPortConnectorType

Object ID

1.3.6.1.4.1.674.10892.1.1000.60.1.7

Description

Defines the connector type of the SCSI port.

Syntax

DellSCSIPortConnectorType (See Table 13-6)

Access

Read-only

SCSI Port Name
Name

sCSIPortName

Object ID

1.3.6.1.4.1.674.10892.1.1000.60.1.8

Description

Defines the name of the SCSI port.

Syntax

DellString

Access

Read-only

SCSI Port BIOS Connector Type
Name

sCSIPortBIOSConnectorType

Object ID

1.3.6.1.4.1.674.10892.1.1000.60.1.9

Description

Defines the BIOS connector type of the SCSI port.

Syntax

DellGenericPortConnectorType

Access

Read-only

Parallel Port Table
Name

parallelPortTable

Object ID

1.3.6.1.4.1.674.10892.1.1000.70

Description

Defines the Parallel Port Table.

Syntax

IntegerParallelPortTableEntry

Access

Not accessible

246

Port Group

Parallel Port Table Entry
Name

parallelPortTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.1000.70.1

Description

Defines the Parallel Port Table entry.

Syntax

ParallelPortTableEntry

Access

Not accessible

Index

parallelPortchassisIndex, parallelPortIndex

Parallel Port Chassis Index
Name

parallelPortchassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.1000.70.1.1

Description

Defines the index (one-based) of this chassis.

Syntax

DellObjectRange

Access

Read-only

Parallel Port Index
Name

parallelPortIndex

Object ID

1.3.6.1.4.1.674.10892.1.1000.70.1.2

Description

Defines the index of the parallel ports in this chassis.

Syntax

DellObjectRange

Access

Read-only

Parallel Port State Capabilities
Name

parallelPortStateCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.1000.70.1.3

Description

Defines the capabilities of the parallel port.

Syntax

DellStateSettings

Access

Read-write

Port Group

247

Parallel Port State Settings
Name

parallelPortStateSettings

Object ID

1.3.6.1.4.1.674.10892.1.1000.70.1.4

Description

Defines the state and settings of the parallel port.

Syntax

DellStateSettings

Access

Read-write

Parallel Port Status
Name

parallelPortStatus

Object ID

1.3.6.1.4.1.674.10892.1.1000.70.1.5

Description

Defines the status of the parallel port.

Syntax

DellStatus

Access

Read-only

Parallel Port Security State
Name

DellPortSecurityState

Object ID

1.3.6.1.4.1.674.10892.1.1000.70.1.6

Description

Defines the security state of the parallel port.

Syntax

DellStatus

Access

Read-only

Parallel Port Connector Type
Name

parallelPortConnectorType

Object ID

1.3.6.1.4.1.674.10892.1.1000.70.1.7

Description

Defines the connector type of the parallel port.

Syntax

DellParallelPortConnectorType

Access

Read-only

248

Port Group

Parallel Port Name
Name

parallelPortName

Object ID

1.3.6.1.4.1.674.10892.1.1000.70.1.8

Description

Defines the name of the parallel port.

Syntax

DellString

Access

Read-only

Parallel Port Connector Pin Out
Name

parallelPortConnectorPinOut

Object ID

1.3.6.1.4.1.674.10892.1.1000.70.1.9

Description

Defines the pinout of the parallel port.

Syntax

DellParallelPortConnectorPinout

Access

Read-only

Parallel Port Capabilities Unique
Name

parallelPortCapabilitiesUnique

Object ID

1.3.6.1.4.1.674.10892.1.1000.70.1.10

Description

Defines the capabilities of the parallel port.

Syntax

DellParallelPortConnectorPinout

Access

Read-only

Parallel Port Base I/O Address
Name

parallelPortBaseIOAddress

Object ID

1.3.6.1.4.1.674.10892.1.1000.70.1.11

Description

Defines the Base Input/Output (I/O) address of the parallel port.

Syntax

DellUnsigned64BitRange

Access

Read-only

Port Group

249

Parallel Port IRQ Level
Name

parallelPortIRQLevel

Object ID

1.3.6.1.4.1.674.10892.1.1000.70.1.12

Description

Defines the Interrupt Request Level (IRQ) of the parallel port.

Syntax

DellUnsigned8BitRange

Access

Read-only

Parallel Port DMA Support
Name

parallelPortDMASupport

Object ID

1.3.6.1.4.1.674.10892.1.1000.70.1.13

Description

Defines if direct memory access (DMA) is supported by the
parallel port.

Syntax

DellBoolean

Access

Read-only

Serial Port Table
Name

serialPortTable

Object ID

1.3.6.1.4.1.674.10892.1.1000.80

Description

Defines the Serial Port Table.

Syntax

IntegerSerialPortTableEntry

Access

Not accessible

Serial Port Table Entry
Name

serialPortTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.1000.80.1

Description

Defines the Serial Port Table entry.

Syntax

SerialPortTableEntry

Access

Not accessible

Index

serialPortchassisIndex, serialPortIndex

250

Port Group

Serial Port Chassis Index
Name

serialPortchassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.1000.80.1.1

Description

Defines the index (one-based) of this chassis.

Syntax

DellObjectRange

Access

Read-only

Serial Port Index
Name

serialPortIndex

Object ID

1.3.6.1.4.1.674.10892.1.1000.80.1.2

Description

Defines the index of the serial ports in this chassis.

Syntax

DellObjectRange

Access

Read-only

Serial Port State Capabilities
Name

serialPortStateCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.1000.80.1.3

Description

Defines the capabilities of the serial port.

Syntax

DellStateCapabilities

Access

Read-only

Serial Port State Settings
Name

serialPortStateSettings

Object ID

1.3.6.1.4.1.674.10892.1.1000.80.1.4

Description

Defines the state and settings of the serial port.

Syntax

DellStateSettings

Access

Read-write

Port Group

251

Serial Port Status
Name

serialPortStatus

Object ID

1.3.6.1.4.1.674.10892.1.1000.80.1.5

Description

Defines the status of the serial port.

Syntax

DellStatus

Access

Read-only

Serial Port Security State
Name

serialPortSecurityState

Object ID

1.3.6.1.4.1.674.10892.1.1000.80.1.6

Description

Defines the security settings of the serial port.

Syntax

DellPortSecurityState

Access

Read-only

Serial Port Connector Type
Name

serialPortConnectorType

Object ID

1.3.6.1.4.1.674.10892.1.1000.80.1.7

Description

Defines connector type of the serial port.

Syntax

DellSerialPortConnectorType

Access

Read-only

Serial Port Name
Name

serialPortName

Object ID

1.3.6.1.4.1.674.10892.1.1000.80.1.8

Description

Defines the name of the serial port.

Syntax

DellString

Access

Read-only

252

Port Group

Serial Port Maximum Speed
Name

serialPortMaximumSpeed

Object ID

1.3.6.1.4.1.674.10892.1.1000.80.1.9

Description

Defines the maximum speed the serial interface can support in
bits per second (bps).

Syntax

DellUnsigned32BitRange

Access

Read-only

Serial Port Capabilities Unique
Name

serialPortCapabilitiesUnique

Object ID

1.3.6.1.4.1.674.10892.1.1000.80.1.10

Description

Defines additional capabilities of the serial port.

Syntax

DellSerialPortCapabilitiesUnique

Access

Read-only

Serial Port Base I/O Address
Name

serialPortBaseIOAddress

Object ID

1.3.6.1.4.1.674.10892.1.1000.80.1.11

Description

Defines the base I/O address of the serial port.

Syntax

DellUnsigned64BitRange

Access

Read-only

Serial Port IRQ Level
Name

serialPortIRQLevel

Object ID

1.3.6.1.4.1.674.10892.1.1000.80.1.12

Description

Defines the IRQ of the serial port.

Syntax

DellUnsigned8BitRange

Access

Read-only

Port Group

253

Universal Serial Bus (USB) Port Table
Name

uSBPortTable

Object ID

1.3.6.1.4.1.674.10892.1.1000.90

Description

Defines the USB Port Table.

Syntax

IntegerUSBPortTableEntry

Access

Not accessible

USB Port Table Entry
Name

uSBPortTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.1000.90.1

Description

Defines the USB Port Table entry.

Syntax

USBPortTableEntry

Access

Not accessible

Index

uSBPortchassisIndex, uSBPortIndex

USB Port Chassis Index
Name

uSBPortchassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.1000.90.1.1

Description

Defines the index (one-based) of this chassis.

Syntax

DellObjectRange

Access

Read-only

USB Port Index
Name

uSBPortIndex

Object ID

1.3.6.1.4.1.674.10892.1.1000.90.1.2

Description

Defines the index of the USB ports in this chassis

Syntax

DellObjectRange

Access

Read-only

254

Port Group

USB Port State Capabilities
Name

uSBPortStateCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.1000.90.1.3

Description

Defines the capabilities of the USB port.

Syntax

DellStateCapabilities

Access

Read-only

USB Port State Settings
Name

uSBPortStateSettings

Object ID

1.3.6.1.4.1.674.10892.1.1000.90.1.4

Description

Defines the state and settings of the USB port.

Syntax

DellStateSettings

Access

Read-write

USB Port Status
Name

uSBPortStatus

Object ID

1.3.6.1.4.1.674.10892.1.1000.90.1.5

Description

Defines the state of the USB port.

Syntax

DellStatus

Access

Read-only

USB Port Security State
Name

uSBPortSecurityState

Object ID

1.3.6.1.4.1.674.10892.1.1000.90.1.6

Description

Defines the security settings of the USB port.

Syntax

DellPortSecurityState

Access

Read-only

Port Group

255

USB Port Connector Type
Name

uSBPortConnectorType

Object ID

1.3.6.1.4.1.674.10892.1.1000.90.1.7

Description

Defines the connector type of the USB port.

Syntax

DellUSBPortConnectorType

Access

Read-only

USB Port Name
Name

uSBPortName

Object ID

1.3.6.1.4.1.674.10892.1.1000.90.1.8

Description

Defines the name of the USB port.

Syntax

DellString

Access

Read-only

USB Port BIOS Connector Type
Name

uSBPortBIOSConnectorType

Object ID

1.3.6.1.4.1.674.10892.1.1000.90.1.9

Description

Defines the BIOS connector type of the USB port.

Syntax

DellGenericPortConnectorType

Access

Read-only

256

Port Group

Port Group Variable Values
This section includes definitions for server administrator-specific variable
values used in this section.
Table 13-1.

Pointing Port Connector Type

Variable Name: DellPointingPortConnectorType
Data Type: Integer
Possible Data Values

Meaning of Data Value

connectorPortTypeIsOther(1)

The pointing port connector type is
not one of the following:

connectorPortTypeIsUnknown(2)

The pointing port connector type is
unknown.

connectorPortTypeIsSerial(3)

The pointing port connector type is
serial.

connectorPortTypeIsPS2(4)

The pointing port connector type is a
Personal System/2 (PS/2).

connectorPortTypeIsInfrared(5)

The pointing port connector type is
infrared.

connectorPortTypeIsHPHIL(6)

The pointing port connector type is
HP-HIL.

connectorPortTypeIsBusMouse(7)

The pointing port connector type is a
bus mouse.

connectorPortTypeIsADB(8)

The pointing port connector type is
ADB.

connectorPortTypeIsDB9(9)

The pointing port connector type is
nine-pin DB-9.

connectorPortTypeIsMicroDIN(10)

The pointing port connector type is
micro Deutsche Industrie Norm
(DIN).

connectorPortTypeIsAccessBusUSB
(11)

The pointing port connector type is
Access Bus USB.

connectorPortTypeIsPC98(12)

The port connector type is a PC-98.

Port Group

257

Table 13-2. Keyboard Port Connector Types
Variable Name: DellKeyboardPortConnectorType
Data Type: Integer
Possible Data Values

Meaning of Data Value

connectorPortTypeIsOther(1)

The keyboard port connector
type is not one of the following:

connectorPortTypeIsUnknown(2)

The keyboard port connector
type is unknown.

connectorPortTypeIsMiniDIN(3)

The keyboard port connector
type is a mini DIN.

connectorPortTypeIsMicroDIN(4)

The keyboard port connector
type is a MicroDIN.

connectorPortTypeIsPS2(5)

The keyboard port connector
type is PS/2.

connectorPortTypeIsInfrared(6)

The keyboard port connector
type is infrared.

connectorPortTypeIsHPHIL(7)

The keyboard port connector
type is HP-HIL.

connectorPortTypeIsDB9(8)

The keyboard port connector
type is DB-9.

connectorPortTypeIsAccessBusUSB(9) The keyboard port connector
type is bus USB.
connectorPortTypeIsPC98(10)

258

Port Group

The keyboard port connector
type is PC-98.

Table 13-3.

Processor Port Connector Types

Variable Name: DellProcessorPortConnectorType
Data Type: Integer
Possible Data Values

Meaning of Data Value

connectorPortTypeIsOther(1)

The processor port connector
type is not one of the
following:

connectorPortTypeIsUnknown(2)

The processor port connector
type is unknown.

connectorPortTypeIsDaughterdBoard(3)

The processor port connector
type is a daughter board.

connectorPortTypeIsZIFSocket(4)

The processor port connector
type is a zero insertion force
(ZIF) socket.

connectorPortTypeIsAPiggyBackBoard(5) The processor port connector
type is a replacement
piggyback board.
connectorPortTypeIsNone(6)

There is no processor port
connector; processor is
soldered in place.

connectorPortTypeIsLIFSocket(7)

The processor port connector
type is a low insertion force
(LIF) socket.

connectorPortTypeIsSlot1(8)

The processor port connector
type is a slot one.

connectorPortTypeIsSlot2(9)

The processor port connector
type is a slot two.

connectorPortTypeIs370PinSocket(10)

The processor port connector
type is a 370 pin socket.

Port Group

259

Table 13-4. Memory Device Port Connector Types
Variable Name: DellMemoryDevicePortConnectorType
Data Type: Integer
Possible Data Value

Meaning of Data Value

connectorPortTypeIsOther(1)

The memory device port
connector type is not one of
the following:

connectorPortTypeIsUnknown(2)

The memory device port
connector type is unknown.

connectorPortTypeIsSIMM(3)

The memory device port
connector type is a single
in-line memory module
(SIMM).

connectorPortTypeIsSIP(4)

The memory device port
connector type is a SIP.

connectorPortTypeIsAChip(5)

The memory device port
connector type is a chip.

connectorPortTypeIsDIP(6)

The memory device port
connector type is a dual
in-line package (DIP).

connectorPortTypeIsZIP(7)

The memory device port
connector type is a ZIP.

connectorPortTypeIsAProprietaryCard(8) The memory device port
connector type is a
proprietary card.
connectorPortTypeIsDIMM(9)

The memory device port
connector type is a dual
in-line memory module
(DIMM).

connectorPortTypeIsTSOP(10)

The memory device port
connector type is a TSOP.

connectorPortTypeIsARowOfChips(11)

The memory device port
connector type is a row of
chips.

260

Port Group

Table 13-4.

Memory Device Port Connector Types (continued)

Variable Name: DellMemoryDevicePortConnectorType
Data Type: Integer
Possible Data Value

Meaning of Data Value

connectorPortTypeIsRIMM(12)

The memory device port
connector type is a Rambus
Inline Memory Module
(RIMM).

connectorPortTypeIsSODIMM(13)

The memory device port
connector type is a small
outline, dual in-line
memory module
(SODIMM).

connectorPortTypeIsSRIMM(14)

The memory device port
connector type is a SRIMM.

Table 13-5.

Monitor Port Connector Types

Variable Name: DellMonitorPortConnectorType
Data Type: Integer
Possible Data Values

Meaning of Data Value

connectorPortTypeIsOther(1)

The monitor port connector type
is not one of the following:

connectorPortTypeIsUnknown(2)

The monitor port connector type
is unknown.

connectorPortTypeIsDB15PinMale(3)

The monitor port connector type
is a male DB-15.

connectorPortTypeIsDB15PinFemale(4) The monitor port connector type
is a female DB-15.

Port Group

261

Table 13-6. SCSI Port Connector Types
Variable Name: DellSCSIPortConnectorType
Data Type: Integer
Possible Data Values

Meaning of Data Value

connectorPortTypeIsOther(1)

The SCSI port connector type
is not one of the following:

connectorPortTypeIsUnknown(2)

The SCSI port connector type
is unknown.

connectorPortTypeIsDIN25pin(3)

The SCSI port connector type
is a DIN 25-pin.

connectorPortTypeIsDIN50pin(4)

The SCSI port connector type
is a DIN 50-pin.

connectorPortTypeIsDIN68pin(5)

The SCSI port connector type
is a DIN 68-pin.

262

Port Group

14
14

Device Group

The Device Group provides information about different types of pointing,
keyboard, processor, cache, memory, and peripheral component interconnect
(PCI) devices. Variables in this group cover information about type, settings,
configuration, manufacturer, address or location, and if applicable, the speed
of the device.

Device Tables
The following management information base (MIB) tables define objects in
the Device Group:
•

"Pointing Device Table" on page 264

•

"Keyboard Device Table" on page 266

•

"Processor Device Table" on page 269

•

"Processor Device Status Table" on page 277

•

"Cache Device Table" on page 279

•

"Memory Device Table" on page 285

•

"Memory Device Mapped Address Table" on page 293

•

"Generic Device Table" on page 296

•

"PCI Device Table" on page 299

•

"PCI Device Configuration Space Table" on page 302

•

"Network Device Table" on page 305

•

"Managed System Services Device Table" on page 313

•

"SD Card Unit Table" on page 315

•

"SD Card Device Table" on page 318

Device Group

263

Pointing Device Table
Name

pointingDeviceTable

Object ID

1.3.6.1.4.1.674.10892.1.1100.10

Description

Defines the Pointing Device Table. This group of objects
references the Pointing Port Index (See Section 12).

Syntax

SEQUENCE OF PointingDeviceTableEntry

Access

Not accessible

Pointing Device Table Entry
Name

pointingDeviceTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.1100.10.1

Description

Defines the Pointing Device Table entry.

Syntax

PointingDeviceTableEntry

Access

Not accessible

Index

pointingDevicechassisIndex, pointingDeviceIndex

Pointing Device Chassis Index
Name

pointingDevicechassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.1100.10.1.1

Description

Defines the index (one-based) of this chassis.

Syntax

DellObjectRange

Access

Read-only

Pointing Device Index
Name

pointingDeviceIndex

Object ID

1.3.6.1.4.1.674.10892.1.1100.10.1.2

Description

Defines the index of the pointing device in this chassis.

Syntax

DellObjectRange

Access

Read-only

264

Device Group

Pointing Device State Capabilities
Name

pointingDeviceStateCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.1100.10.1.3

Description

Defines the capabilities of the pointing device.

Syntax

DellStateCapabilities

Access

Read-only

Pointing Device State Settings
Name

pointingDeviceStateSettings

Object ID

1.3.6.1.4.1.674.10892.1.1100.10.1.4

Description

Defines the state of the pointing device.

Syntax

DellStateSettings

Access

Read-write

Pointing Device Status
Name

pointingDeviceStatus

Object ID

1.3.6.1.4.1.674.10892.1.1100.10.1.5

Description

Defines the status of the pointing device.

Syntax

DellStatus

Access

Read-only

Pointing Port Index Reference
Name

pointingPortIndexReference

Object ID

1.3.6.1.4.1.674.10892.1.1100.10.1.6

Description

Defines the index to the pointing port in this chassis.

Syntax

DellObjectRange

Access

Read-only

Device Group

265

Pointing Device Type
Name

pointingDeviceType

Object ID

1.3.6.1.4.1.674.10892.1.1100.10.1.7

Description

Defines the type of the pointing device.

Syntax

DellPointingDeviceType (See Table 14-1)

Access

Read-only

Pointing Device Number of Buttons
Name

pointingDeviceNumberofButtons

Object ID

1.3.6.1.4.1.674.10892.1.1100.10.1.8

Description

Defines the number of buttons on the pointing device.

Syntax

DellUnsigned8BitRange

Access

Read-only

Keyboard Device Table
Name

keyboardDeviceTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.1100.20

Description

Defines the Keyboard Device Table. This table references the
Keyboard Port Index (See Section 12).

Syntax

SEQUENCE OF KeyboardDeviceTableEntry

Access

Not accessible

Keyboard Device Table Entry
Name

keyboardDeviceTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.1100.20.1

Description

Defines the Keyboard Device Table entry.

Syntax

KeyboardDeviceTableEntry

Access

Not accessible

Index

keyboardDevicechassisIndex, keyboardDeviceIndex

266

Device Group

Keyboard Device Chassis Index
Name

keyboardDevicechassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.1100.20.1.1

Description

Defines the index (one-based) of this chassis.

Syntax

DellObjectRange

Access

Read-only

Keyboard Device Index
Name

keyboardDeviceIndex

Object ID

1.3.6.1.4.1.674.10892.1.1100.20.1.2

Description

Defines the index of the keyboard device for this chassis.

Syntax

DellObjectRange

Access

Read-only

Keyboard Device State Capabilities
Name

keyboardDeviceStateCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.1100.20.1.3

Description

Defines the capabilities of the keyboard device.

Syntax

DellStateCapabilities

Access

Read-only

Keyboard Device State Settings
Name

keyboardDeviceStateSettings

Object ID

1.3.6.1.4.1.674.10892.1.1100.20.1.4

Description

Defines the state of the keyboard device.

Syntax

DellStatesSettings

Access

Read-write

Device Group

267

Keyboard Device Status
Name

keyboardDeviceStatus

Object ID

1.3.6.1.4.1.674.10892.1.1100.20.1.5

Description

Defines the status of the keyboard device.

Syntax

DellStatus

Access

Read-only

Keyboard Port Index Reference
Name

keyboardPortIndexReference

Object ID

1.3.6.1.4.1.674.10892.1.1100.20.1.6

Description

Defines the index to the associated the keyboard port in
this chassis.

Syntax

DellStatus

Access

Read-only

Keyboard Device Type Name
Name

keyboardDeviceTypeName

Object ID

1.3.6.1.4.1.674.10892.1.1100.20.1.7

Description

Defines the name of the keyboard type.

Syntax

DellString

Access

Read-only

Keyboard Device Layout Name
Name

keyboardDeviceLayoutName

Object ID

1.3.6.1.4.1.674.10892.1.1100.20.1.8

Description

Defines the name of the keyboard layout.

Syntax

DellString

Access

Read-only

268

Device Group

Processor Device Table
Name

processorDeviceTable

Object ID

1.3.6.1.4.1.674.10892.1.1100.30

Description

Defines the Processor Device Table.

Syntax

SEQUENCE OF ProcessorDeviceTableEntry

Access

Not accessible

Processor Device Table Entry
Name

processorDeviceTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.1100.30.1

Description

Defines the Processor Device Table entry.

Syntax

ProcessorDeviceTableEntry

Access

Not accessible

Index

processorDevicechassisIndex, processorDeviceIndex

Processor Device Chassis Index
Name

processorDevicechassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.1100.30.1.1

Description

Defines the index (one-based) of this chassis.

Syntax

DellObjectRange

Access

Read-only

Processor Device Index
Name

processorDeviceIndex

Object ID

1.3.6.1.4.1.674.10892.1.1100.30.1.2

Description

Defines the index of the processor device in this chassis.

Syntax

DellObjectRange

Access

Read-only

Device Group

269

Processor Device State Capabilities
Name

processorDeviceStateCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.1100.30.1.3

Description

Defines the capabilities of the processor device.

Syntax

DellStateCapabilities

Access

Read-only

Processor Device State Settings
Name

processorDeviceStateSettings

Object ID

1.3.6.1.4.1.674.10892.1.1100.30.1.4

Description

Defines the state of the processor device.

Syntax

DellStateSettings

Access

Read-write

Processor Device Status
Name

processorDeviceStatus

Object ID

1.3.6.1.4.1.674.10892.1.1100.30.1.5

Description

Defines the status of the processor device.

Syntax

DellStatus

Access

Read-only

Processor Port Index Reference
Name

processorPortIndexReference

Object ID

1.3.6.1.4.1.674.10892.1.1100.30.1.6

Description

Defines the index to the associated processor port in this
chassis.

Syntax

DellObjectRange

Access

Read-only

270

Device Group

Processor Device Type
Name

processorDeviceType

Object ID

1.3.6.1.4.1.674.10892.1.1100.30.1.7

Description

Defines the type of processor device.

Syntax

DellProcessorDeviceType (See Table 14-4)

Access

Read-only

Processor Device Manufacturer Name
Name

processorDeviceManufacturerName

Object ID

1.3.6.1.4.1.674.10892.1.1100.30.1.8

Description

Defines the name of manufacturer of the processor device.

Syntax

DellString

Access

Read-only

Processor Device Status State
Name

processorDeviceStatusState

Object ID

1.3.6.1.4.1.674.10892.1.1100.30.1.9

Description

Defines the status state of the processor device.

Syntax

DellProcessorDeviceStatusState (See Table 14-2)

Access

Read-only

Processor Device Family
Name

processorDeviceFamily

Object ID

1.3.6.1.4.1.674.10892.1.1100.30.1.10

Description

Defines the family of the processor device.

Syntax

DellProcessorDeviceFamily (See Table )

Access

Read-only

Device Group

271

Processor Device Maximum Speed
Name

processorDeviceMaximumSpeed

Object ID

1.3.6.1.4.1.674.10892.1.1100.30.1.11

Description

Defines the maximum speed of the processor device in
megahertz (MHz). A zero (0) indicates that the speed is
unknown.

Syntax

DellUnsigned32BitRange

Access

Read-only

Processor Device Current Speed
Name

processorDeviceCurrentSpeed

Object ID

1.3.6.1.4.1.674.10892.1.1100.30.1.12

Description

Defines the current speed of the processor device in MHz. A
zero (0) indicates that the speed is unknown.

Syntax

DellUnsigned32BitRange

Access

Read-only

Processor Device External Clock Speed
Name

processorDeviceExternalClockSpeed

Object ID

1.3.6.1.4.1.674.10892.1.1100.30.1.13

Description

Defines the speed of the external clock (the front-side bus
speed) for the processor device in MHz. A zero (0) indicates
that the speed is unknown.

Syntax

DellUnsigned32BitRange

Access

Read-only

272

Device Group

Processor Device Voltage
Name

processorDeviceVoltage

Object ID

1.3.6.1.4.1.674.10892.1.1100.30.1.14

Description

Defines the voltage powering the processor device in millivolts.
A zero (0) indicates the speed is unknown.

Syntax

DellSigned32BitRange

Access

Read-only

Processor Device Upgrade Information
Name

processorDeviceUpgradeInformation

Object ID

1.3.6.1.4.1.674.10892.1.1100.30.1.15

Description

Defines the processor upgrade information for the processor device.

Syntax

DellProcessorUpgradeInformation (See Table 14-5)

Access

Read-only

Processor Device Version Name
Name

processorDeviceVersionName

Object ID

1.3.6.1.4.1.674.10892.1.1100.30.1.16

Description

Defines the version name of the processor device.

Syntax

DellString

Access

Read-only

Device Group

273

Processor Device Core Count
Name

processorDeviceCoreCount

Object ID

1.3.6.1.4.1.674.10892.1.1100.30.1.17

Description

Defines the number of processor cores detected for the
processor device.

Syntax

DellUnsigned32BitRange

Access

Read-only

Processor Device Core Enabled Count
Name

processorDeviceCoreEnabledCount

Object ID

1.3.6.1.4.1.674.10892.1.1100.30.1.18

Description

Defines the number of processor cores enabled for the
processor device.

Syntax

DellUnsigned32BitRange

Access

Read-only

Processor Device Thread Count
Name

processorDeviceThreadCount

Object ID

1.3.6.1.4.1.674.10892.1.1100.30.1.19

Description

Defines the number of processor threads detected for the
processor device.

Syntax

DellUnsigned32BitRange

Access

Read-only

274

Device Group

Processor Device Characteristics
Name

processorDeviceCharacteristics

Object ID

1.3.6.1.4.1.674.10892.1.1100.30.1.20

Description

This attribute defines characteristics of the processor device.
This attribute is a bit field where a bit has the meaning defined
below when set to 1 (one).

NOTE: Bits 2-15 need to be examined in the context of bit 1. If bit 1 is
set, the processor characteristics are unknown and bits 2-15
cannot be used to determine if the functions associated with the
bits are supported.
Bit Position
-------------Bit 0
Bit 1
Bit 2
Bit 3-15

Meaning if Set
-----------------Reserved
Unknown
64-bit capable
Reserved

Syntax

DellUnsigned16BitRange

Access

Read-only

Processor Device Extended Capabilities
Name

processorDeviceExtendedCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.1100.30.1.21

Description

This attribute defines extended capabilities of the processor
device. This attribute is a bit field where a bit has the meaning
defined below when set to 1 (one).
Bit Position
---------------Bit 0
Bit 1
Bit 2
Bit 3

Meaning if Set
------------------Virtualization Technology (VT) supported
Demand-Based Switching (DBS) supported
eXecute Disable (XD) supported
Hyper-Threading (HT) supported

Syntax

DellUnsigned16BitRange

Access

Read-only

Device Group

275

Processor Device Extended Settings
Name

processorDeviceExtendedSettings

Object ID

1.3.6.1.4.1.674.10892.1.1100.30.1.22

Description

This attribute defines extended settings of the processor device.
This attribute is a bit field where a bit has the meaning defined
below when set to 1 (one).
Bit Position
--------------Bit 0
Bit 1
Bit 2
Bit 3

Meaning if Set
------------Virtualization Technology (VT) enabled
Demand Based Switching (DBS) enabled
eXecute Disable (XD) enabled
Hyper-Threading (HT) enabled

Syntax

DellUnsigned16BitRange

Access

Read-only

Processor Device Brand Name
Name

processorDeviceBrandName

Object ID

1.3.6.1.4.1.674.10892.1.1100.30.1.23

Description

Defines the brand of the processor device.

Syntax

DellString

Access

Read-only

Processor Device Model Name
Name

processorDeviceModelName

Object ID

1.3.6.1.4.1.674.10892.1.1100.30.1.24

Description

Defines the model of the processor device.

Syntax

DellString

Access

Read-only

276

Device Group

Processor Device Stepping Name
Name

processorDeviceSteppingName

Object ID

1.3.6.1.4.1.674.10892.1.1100.30.1.25

Description

Defines the stepping of the processor device.

Syntax

DellString

Access

Read-only

Processor Device Status Table
Name

processorDeviceStatusTable

Object ID

1.3.6.1.4.1.674.10892.1.1100.32

Description

Defines the Processor Device Status Table.

Syntax

SEQUENCE OF ProcessorDeviceStatusTableEntry

Access

Not accessible

Processor Device Status Table Entry
Name

processorDeviceStatusTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.1100.32.1

Description

Defines the Processor Device Status Table Entry.

Syntax

ProcessorDeviceStatusTableEntry

Access

Not accessible

Index

processorDeviceStatusChassisIndex,
processorDeviceStatusIndex

Processor Device Status Chassis Index
Name

processorDeviceStatusChassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.1100.32.1.1

Description

Defines the index (one-based) of the associated chassis.

Syntax

DellObjectRange

Access

Read-only

Device Group

277

Processor Device Status Index
Name

processorDeviceStatusIndex

Object ID

1.3.6.1.4.1.674.10892.1.1100.32.1.2

Description

Defines the index (one-based) of the processor device status
probe.

Syntax

DellObjectRange

Access

Read-only

Processor Device Status State Capabilities
Name

processorDeviceStatusStateCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.1100.32.1.3

Description

Defines the state capabilities of the processor device status probe.

Syntax

DellStateCapabilities

Access

Read-only

Processor Device Status State Settings
Name

processorDeviceStatusStateSettings

Object ID

1.3.6.1.4.1.674.10892.1.1100.32.1.4

Description

Defines the state settings of the processor device status probe.

Syntax

DellStateSettings

Access

Read-write

Processor Device Status Status
Name

processorDeviceStatusStatus

Object ID

1.3.6.1.4.1.674.10892.1.1100.32.1.5

Description

Defines the status of the processor device status probe. This
status is joined into the processorDeviceStatus attribute.

Syntax

DellStatus

Access

Read-only

278

Device Group

Processor Device Status Reading
Name

processorDeviceStatusReading

Object ID

1.3.6.1.4.1.674.10892.1.1100.32.1.6

Description

Defines the reading of the processor device status probe.

Syntax

DellProcessorDeviceStatusReading

Access

Read-only

Processor Device Status Location Name
Name

processorDeviceStatusLocationName

Object ID

1.3.6.1.4.1.674.10892.1.1100.32.1.7

Description

Defines the location name of the processor device status probe.

Syntax

DellString

Access

Read-only

Processor Device Status Port Index Reference
Name

processorDeviceStatusPortIndexReference

Object ID

1.3.6.1.4.1.674.10892.1.1100.32.1.8

Description

Defines the index (one-based) of the associated processor port
in the same chassis.

Syntax

DellObjectRange

Access

Read-only

Cache Device Table
Name

cacheDeviceTable

Object ID

1.3.6.1.4.1.674.10892.1.1100.40

Description

Defines the Cache Device Table.

Syntax

SEQUENCE OF CacheDeviceTableEntry

Access

Not accessible

Device Group

279

Cache Device Table Entry
Name

cacheDeviceTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.1100.40.1

Description

Defines the Cache Device Table entry.

Syntax

CacheDeviceTableEntry

Access

Not accessible

Index

cacheDevicechassisIndex, cacheDeviceIndex

Cache Device Chassis Index
Name

cacheDevicechassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.1100.40.1.1

Description

Defines the index (one-based) of this chassis.

Syntax

DellObjectRange

Access

Read-only

Cache Device Index
Name

cacheDeviceIndex

Object ID

1.3.6.1.4.1.674.10892.1.1100.40.1.2

Description

Defines the index of the cache device in this chassis.

Syntax

DellObjectRange

Access

Read-only

Cache Device State Capabilities
Name

cacheDeviceStateCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.1100.40.1.3

Description

Defines the capabilities of the cache device.

Syntax

DellStateCapabilities

Access

Read-only

280

Device Group

Cache Device State Settings
Name

cacheDeviceStateSettings

Object ID

1.3.6.1.4.1.674.10892.1.1100.40.1.4

Description

Defines the state of the cache device.

Syntax

DellStateSettings

Access

Read-write

Cache Device Status
Name

cacheDeviceStatus

Object ID

1.3.6.1.4.1.674.10892.1.1100.40.1.5

Description

Defines the status of the cache device.

Syntax

DellStatus

Access

Read-only

Cache Device Processor Device Index Reference
Name

cacheDeviceprocessorDeviceIndexReference

Object ID

1.3.6.1.4.1.674.10892.1.1100.40.1.6

Description

Defines the index number of the processor device with which
this cache device is associated.

Syntax

DellObjectRange

Access

Read-only

Cache Device Type
Name

cacheDeviceType

Object ID

1.3.6.1.4.1.674.10892.1.1100.40.1.7

Description

Defines the type of cache device.

Syntax

DellCacheDeviceType (See Table 14-7)

Access

Read-only

Device Group

281

Cache Device Location
Name

cacheDeviceLocation

Object ID

1.3.6.1.4.1.674.10892.1.1100.40.1.8

Description

Defines the location of the cache device.

Syntax

DellCacheDeviceLocation (See Table 14-13)

Access

Read-only

Cache Device Status State
Name

cacheDeviceStatusState

Object ID

1.3.6.1.4.1.674.10892.1.1100.40.1.9

Description

Defines the status state of the cache device.

Syntax

DellCacheDeviceStatusState (See Table 14-10)

Access

Read-only

Cache Device External Socket Name
Name

cacheDeviceExternalSocketName

Object ID

1.3.6.1.4.1.674.10892.1.1100.40.1.10

Description

Defines the external socket name of the cache device, if the
cache is socketed.

Syntax

DellString

Access

Read-only

Cache Device Level
Name

cacheDeviceLevel

Object ID

1.3.6.1.4.1.674.10892.1.1100.40.1.11

Description

Defines the level of the cache device.

Syntax

DellCacheDeviceLevel (See Table 14-8)

Access

Read-only

282

Device Group

Cache Device Maximum Size
Name

cacheDeviceMaximumSize

Object ID

1.3.6.1.4.1.674.10892.1.1100.40.1.12

Description

Defines the maximum size of the cache device in
kilobytes (KB). A zero (0) indicates that the size is unknown.

Syntax

DellUnsigned32BitRange

Access

Read-only

Cache Device Current Size
Name

cacheDeviceCurrentSize

Object ID

1.3.6.1.4.1.674.10892.1.1100.40.1.13

Description

Defines the current size of the cache device in KB. A zero (0)
indicates that the size is unknown.

Syntax

DellUnsigned32BitRange

Access

Read-only

Cache Device Speed
Name

cacheDeviceSpeed

Object ID

1.3.6.1.4.1.674.10892.1.1100.40.1.14

Description

Defines the speed of the cache device in nanoseconds. A zero (0)
indicates that the speed is unknown.

Syntax

DellUnsigned32BitRange

Access

Read-only

Cache Device Write Policy
Name

cacheDeviceWritePolicy

Object ID

1.3.6.1.4.1.674.10892.1.1100.40.1.15

Description

Defines the write policy of the cache device.

Syntax

DellCacheDeviceWritePolicy (See Table 14-9)

Access

Read-only
Device Group

283

Cache Device Is Socketed
Name

cacheDeviceIsSocketed

Object ID

1.3.6.1.4.1.674.10892.1.1100.40.1.16

Description

Defines if the cache device is socketed.

Syntax

DellBoolean

Access

Read-only

Cache Device Error Checking and Correction (ECC) Type
Name

cacheDeviceECCType

Object ID

1.3.6.1.4.1.674.10892.1.1100.40.1.17

Description

Defines the type of error correction in use by the cache device.

Syntax

DellCacheDeviceECCType (See Table 14-11)

Access

Read-only

Cache Device Associativity
Name

cacheDeviceAssociativity

Object ID

1.3.6.1.4.1.674.10892.1.1100.40.1.18

Description

Defines the type of associativity in use by the cache device.

Syntax

DellCacheDeviceAssociativity (See Table 14-12)

Access

Read-only

Cache Device Supported Type
Name

cacheDeviceSupportedType

Object ID

1.3.6.1.4.1.674.10892.1.1100.40.1.19

Description

Defines the type of static random-access memory (SRAM) that
the cache device can support.

Syntax

DellCacheDeviceSupportedType

Access

Read-only

284

Device Group

Cache Device Current Type
Name

cacheDeviceCurrentType

Object ID

1.3.6.1.4.1.674.10892.1.1100.40.1.20

Description

Defines the current type of SRAM for the cache device.

Syntax

DellCacheDeviceSRAMType (See Table 14-14)

Access

Read-only

Memory Device Table
Name

memoryDeviceTable

Object ID

1.3.6.1.4.1.674.10892.1.1100.50

Description

Defines the Memory Device Table.

Syntax

SEQUENCE OF MemoryDeviceTableEntry

Access

Not accessible

Memory Device Table Entry
Name

memoryDeviceTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.1100.50.1

Description

Defines the Memory Device Table entry.

Syntax

MemoryDeviceTableEntry

Access

Not accessible

Index

memoryDevicechassisIndex, memoryDeviceIndex

Memory Device Chassis Index
Name

memoryDevicechassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.1100.50.1.1

Description

Defines the index (one-based) of this chassis.

Syntax

DellObjectRange

Access

Read-only

Device Group

285

Memory Device Index
Name

memoryDeviceIndex

Object ID

1.3.6.1.4.1.674.10892.1.1100.50.1.2

Description

Defines the index of the memory device in this chassis.

Syntax

DellObjectRange

Access

Read-only

Memory Device State Capabilities
Name

memoryDeviceStateCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.1100.50.1.3

Description

Defines the capabilities of the memory device.

Syntax

DellStateCapabilities

Access

Read-only

Memory Device State Settings
Name

memoryDeviceStateSettings

Object ID

1.3.6.1.4.1.674.10892.1.1100.50.1.4

Description

Defines the state of the memory device.

Syntax

DellStateSettings

Access

Read-write

Memory Device Status
Name

memoryDeviceStatus

Object ID

1.3.6.1.4.1.674.10892.1.1100.50.1.5

Description

Defines the status of the memory device.

Syntax

DellStatus

Access

Read-only

286

Device Group

Memory Device Memory Port Index Reference
Name

memoryDeviceMemoryPortIndexReference

Object ID

1.3.6.1.4.1.674.10892.1.1100.50.1.6

Description

Defines the index of the memory port of which this memory
device is part.

Syntax

DellObjectRange

Access

Read-only

Memory Device Type
Name

memoryDeviceType

Object ID

1.3.6.1.4.1.674.10892.1.1100.50.1.7

Description

Defines the type of the memory device.

Syntax

DellMemoryDeviceType (See Table 14-16)

Access

Read-only

Memory Device Location Name
Name

memoryDeviceLocationName

Object ID

1.3.6.1.4.1.674.10892.1.1100.50.1.8

Description

Defines the location name of the memory device.

Syntax

DellString

Access

Read-write

Device Group

287

Memory Device Error Count

NOTE: "Memory Device Failure Modes" on page 291 has now replaced this
attribute. Memory Device Error Count should no longer be used. If you use the
Memory Device Error Count attribute, the value returned is always zero, and using
the attribute has no effect.
Name

memoryDeviceErrorCount

Object ID

1.3.6.1.4.1.674.10892.1.1100.50.1.9

Description

Defines the total number of Error Checking and Correction (ECC)
errors detected by the memory device. Writing a 0 (zero) to this
variable resets the devices error counts.

Syntax

DellSigned32BitRange

Access

Read-write

Memory Device Bank Location Name
Name

memoryDeviceBankLocationName

Object ID

1.3.6.1.4.1.674.10892.1.1100.50.1.10

Description

Defines the bank location name of the memory device.

Syntax

DellString

Access

Read-only

Memory Device Type Details
Name

memoryDeviceTypeDetails

Object ID

1.3.6.1.4.1.674.10892.1.1100.50.1.11

Description

Defines the detailed type of the memory device.

Syntax

DellMemoryDeviceTypeDetails (See Table 13-17)

Access

Read-only

288

Device Group

Memory Device Form Factor
Name

memoryDeviceFormFactor

Object ID

1.3.6.1.4.1.674.10892.1.1100.50.1.12

Description

Defines the form factor of the memory device.

Syntax

DellMemoryDeviceFormFactor (See Table 14-15)

Access

Read-only

Memory Device Set
Name

memoryDeviceSet

Object ID

1.3.6.1.4.1.674.10892.1.1100.50.1.13

Description

Defines if the memory device is a part of a set. A zero (0)
indicates that this device is not part of a set.

Syntax

DellUnsigned32BitRange

Access

Read-only

Memory Device Size
Name

memoryDeviceSize

Object ID

1.3.6.1.4.1.674.10892.1.1100.50.1.14

Description

Defines the size in KB of the memory device.

Syntax

DellUnsigned32BitRange

Access

Read-only

Memory Device Speed
Name

memoryDeviceSpeed

Object ID

1.3.6.1.4.1.674.10892.1.1100.50.1.15

Description

Defines the speed in nanoseconds of the memory device.
A zero (0) indicates that the speed is unknown.

Syntax

DellUnsigned32BitRange

Access

Read-only

Device Group

289

Memory Device Total Bus Width
Name

memoryDeviceTotalBusWidth

Object ID

1.3.6.1.4.1.674.10892.1.1100.50.1.16

Description

Defines the total number of bits, including ECC, used by the
memory device.

Syntax

DellUnsigned32BitRange

Access

Read-only

Memory Device Total Data Bus Width
Name

memoryDeviceTotalDataBusWidth

Object ID

1.3.6.1.4.1.674.10892.1.1100.50.1.17

Description

Defines the total number of data bits used by the memory
device.

Syntax

DellUnsigned32BitRange

Access

Read-only

Memory Device Correctable Memory Event Count

NOTE: "Memory Device Failure Modes" on page 291 has now replaced this
attribute. Memory Device Correctable Memory Event Count should no longer be
used. If you use the Memory Device Correctable Memory Event Count attribute, the
value returned is always zero, and using the attribute has no effect.
Name

memoryDeviceSingleBitErrorCount

Object ID

1.3.6.1.4.1.674.10892.1.1100.50.1.18

Description

Defines the total number of Correctable Memory Events
detected by the memory device.

Syntax

DellSigned32BitRange

Access

Read-only

290

Device Group

Memory Device Uncorrectable Memory Event Count

NOTE: "Memory Device Failure Modes" on page 291 has now replaced this
attribute. Memory Device Uncorrectable Memory Event Count should no longer be
used. If you use the Memory Device Uncorrectable Memory Event Count attribute,
the value returned is always zero, and using the attribute has no effect.
Name

memoryDeviceMultiBitErrorCount

Object ID

1.3.6.1.4.1.674.10892.1.1100.50.1.19

Description

Defines the total number of Uncorrectable Memory Events
detected by the memory device.

Syntax

DellSigned32BitRange

Access

Read-only

Memory Device Failure Modes
Name

memoryDeviceFailureModes

Object ID

1.3.6.1.4.1.674.10892.1.1100.50.1.20

Description

Defines the failure modes of the memory device when the
memoryDeviceStatus attribute is not OK. It is a bit field that
can be used to report more than one type of failure mode by
using a combination of the defined bit masks.

Syntax

DellMemoryDeviceFailureModes

Access

Read-only

Memory Device Manufacturer Name
Name

memoryDeviceManufacturerName

Object ID

1.3.6.1.4.1.674.10892.1.1100.50.1.21

Description

Defines the manufacturer of the memory device.

Syntax

DellString

Access

Read-only

Device Group

291

Memory Device Part Number Name
Name

memoryDevicePartNumberName

Object ID

1.3.6.1.4.1.674.10892.1.1100.50.1.22

Description

Defines the manufacturer's part number for the memory device.

Syntax

DellString

Access

Read-only

Memory Device Serial Number Name
Name

memoryDeviceSerialNumberName

Object ID

1.3.6.1.4.1.674.10892.1.1100.50.1.23

Description

Defines the serial number of the memory device.

Syntax

DellString

Access

Read-only

Memory Device Asset Tag Name
Name

memoryDeviceAssetTagName

Object ID

1.3.6.1.4.1.674.10892.1.1100.50.1.24

Description

Defines the asset tag of the memory device.

Syntax

DellString

Access

Read-only

Memory Device Speed Name
Name

memoryDeviceSpeedName

Object ID

1.3.6.1.4.1.674.10892.1.1100.50.1.25

Description

This attribute defines the speed of the memory device in string
format with units specified in string.

Syntax

DellString

Access

Read-only

292

Device Group

Memory Device Mapped Address Table
Name

memoryDeviceMappedAddressTable

Object ID

1.3.6.1.4.1.674.10892.1.1100.60

Description

Defines the Memory Device Mapped Address Table.

Syntax

SEQUENCE OF MemoryDeviceMappedAddressTableEntry

Access

Not accessible

Memory Device Mapped Address Table Entry
Name

memoryDeviceMappedAddressTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.1100.60.1

Description

Defines the Memory Device Mapped Address Table entry.

Syntax

MemoryDeviceMappedAddressTableEntry

Access

Not accessible

Index

memoryDeviceMappedAddresschassisIndex,
memoryDeviceMappedAddressIndex

Memory Device Mapped Address Chassis Index
Name

memoryDeviceMappedAddresschassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.1100.60.1.1

Description

Defines the index (one-based) of this chassis.

Syntax

DellObjectRange

Access

Read-only

Device Group

293

Memory Device Mapped Address Index
Name

memoryDeviceMappedAddressIndex

Object ID

1.3.6.1.4.1.674.10892.1.1100.60.1.2

Description

Defines the index (one-based) of the memory device mapped
address in this chassis.

Syntax

DellObjectRange

Access

Read-only

Memory Device Mapped Address State Capabilities
Name

memoryDeviceMappedAddressStateCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.1100.60.1.3

Description

Defines the capabilities of the memory device mapped address.

Syntax

DellStateCapabilities

Access

Read-only

Memory Device Mapped Address State Settings
Name

memoryDeviceMappedAddressStateSettings

Object ID

1.3.6.1.4.1.674.10892.1.1100.60.1.4

Description

Defines the state of the memory device mapped address.

Syntax

DellStateSettings

Access

Read-write

Memory Device Mapped Address Status
Name

memoryDeviceMappedAddressStatus

Object ID

1.3.6.1.4.1.674.10892.1.1100.60.1.5

Description

Defines the status of the memory device mapped address.

Syntax

DellStatus

Access

Read-only

294

Device Group

Memory Device Index Reference
Name

memoryDeviceIndexReference

Object ID

1.3.6.1.4.1.674.10892.1.1100.60.1.6

Description

Defines the index of the memory device(s) associated with this
memory device mapped address.

Syntax

DellObjectRange

Access

Read-only

Memory Device Mapped Address Row Position
Name

memoryDeviceMappedAddressRowPosition

Object ID

1.3.6.1.4.1.674.10892.1.1100.60.1.7

Description

Defines the position of the referenced memory in a row of the
memory device mapped address.

Syntax

DellUnsigned32BitRange

Access

Read-only

Memory Device Mapped Address Interleave Position
Name

memoryDeviceMappedAddressInterleavePosition

Object ID

1.3.6.1.4.1.674.10892.1.1100.60.1.8

Description

Defines the position of the referenced memory in an interleave
of the memory device mapped address.

Syntax

DellUnsigned32BitRange

Access

Read-only

Device Group

295

Memory Device Mapped Address Interleave Depth
Name

memoryDeviceMappedAddressInterleaveDepth

Object ID

1.3.6.1.4.1.674.10892.1.1100.60.1.9

Description

Defines the maximum number of consecutive rows from the
referenced memory device that are accessed in a single
interleaved transfer in the memory device mapped address.

Syntax

DellUnsigned32BitRange

Access

Read-only

Memory Device Mapped Address Starting Address
Name

memoryDeviceMappedAddressStartingAddress

Object ID

1.3.6.1.4.1.674.10892.1.1100.60.1.10

Description

Defines the physical starting address in KB of the memory
device mapped address.

Syntax

DellUnsigned64BitRange

Access

Read-only

Memory Device Mapped Address Ending Address
Name

memoryDeviceMappedAddressEndingAddress

Object ID

1.3.6.1.4.1.674.10892.1.1100.60.1.11

Description

Defines the physical ending address in KB of the memory device
mapped address.

Syntax

DellUnsigned64BitRange

Access

Read-only

Generic Device Table
Name

genericDeviceTable

Object ID

1.3.6.1.4.1.674.10892.1.1100.70

Description

Defines the Generic Device Table.

Syntax

SEQUENCE OF GenericDeviceTableEntry

Access

Not accessible

296

Device Group

Generic Device Table Entry
Name

genericDeviceTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.1100.70.1

Description

Defines the Generic Device Table entry.

Syntax

GenericDeviceTableEntry

Access

Not accessible

Index

genericDevicechassisIndex, genericDeviceIndex

Generic Device Chassis Index
Name

genericDevicechassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.1100.70.1.1

Description

Defines the index (one-based) of this chassis.

Syntax

DellObjectRange

Access

Read-only

Generic Device Index
Name

genericDeviceIndex

Object ID

1.3.6.1.4.1.674.10892.1.1100.70.1.2

Description

Defines the index of the generic device in this chassis.

Syntax

DellObjectRange

Access

Read-only

Generic Device State Capabilities
Name

genericDeviceStateCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.1100.70.1.3

Description

Defines the capabilities of the generic device.

Syntax

DellStateCapabilities

Access

Read-only

Device Group

297

Generic Device State Settings
Name

genericDeviceStateSettings

Object ID

1.3.6.1.4.1.674.10892.1.1100.70.1.4

Description

Defines the state of the generic device.

Syntax

DellStateSettings

Access

Read-write

Generic Device Status
Name

genericDeviceStatus

Object ID

1.3.6.1.4.1.674.10892.1.1100.70.1.5

Description

Defines the status of the generic device.

Syntax

DellStatus

Access

Read-only

Generic Device System Slot Index Reference
Name

genericDeviceSystemSlotIndexReference

Object ID

1.3.6.1.4.1.674.10892.1.1100.70.1.6

Description

Defines the index of the system slot into which this generic
device is plugged.

Syntax

DellObjectRange

Access

Read-only

Generic Device Type
Name

genericDeviceType

Object ID

1.3.6.1.4.1.674.10892.1.1100.70.1.7

Description

Defines the type of the generic device.

Syntax

DellGenericDeviceType (See Table 14-18)

Access

Read-only

298

Device Group

Generic Device Name
Name

genericDeviceName

Object ID

1.3.6.1.4.1.674.10892.1.1100.70.1.8

Description

Defines the name of the generic device.

Syntax

DellString

Access

Read-only

PCI Device Table
Name

pCIDeviceTable

Object ID

1.3.6.1.4.1.674.10892.1.1100.80

Description

Defines the PCI Device Detail Table.

Syntax

SEQUENCE OF PCIDeviceTableEntry

Access

Not accessible

PCI Device Table Entry
Name

pCIDeviceTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.1100.80.1

Description

Defines the PCI Device Table entry.

Syntax

Not accessible

Access

PCIDeviceTableEntry

Index

pCIDevicechassisIndex, pCIDeviceIndex

PCI Device Chassis Index
Name

pCIDevicechassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.1100.80.1.1

Description

Defines the index (one-based) of this chassis.

Syntax

Read-only

Access

DellObjectRange

Device Group

299

PCI Device Index
Name

pCIDeviceIndex

Object ID

1.3.6.1.4.1.674.10892.1.1100.80.1.2

Description

Defines the index (one-based) of the PCI device in this chassis.

Syntax

DellObjectRange

Access

Read-only

PCI Device State Capabilities
Name

pCIDeviceStateCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.1100.80.1.3

Description

Defines the capabilities of the PCI device.

Syntax

DellStateCapabilities

Access

Read-only

PCI Device State Settings
Name

pCIDeviceStateSettings

Object ID

1.3.6.1.4.1.674.10892.1.1100.80.1.4

Description

Defines the state of the PCI device.

Syntax

DellStateSettings

Access

Read-write

PCI Device Status
Name

pCIDeviceStatus

Object ID

1.3.6.1.4.1.674.10892.1.1100.80.1.5

Description

Defines the status of the PCI device.

Syntax

DellStatus

Access

Read-only

300

Device Group

PCI Device System Slot Index Reference
Name

pCIDeviceSystemSlotIndexReference

Object ID

1.3.6.1.4.1.674.10892.1.1100.80.1.6

Description

Defines the index number of the system slot that this PCI
device is in.

Syntax

DellObjectRange

Access

Read-only

PCI Device Data Bus Width
Name

pCIDeviceDataBusWidth

Object ID

1.3.6.1.4.1.674.10892.1.1100.80.1.7

Description

Defines the bus width of the PCI device in this chassis.

Syntax

DellUnsigned32BitRange

Access

Read-only

PCI Device Manufacturer Name
Name

pCIDeviceManufacturerName

Object ID

1.3.6.1.4.1.674.10892.1.1100.80.1.8

Description

Defines the name of the PCI device manufacturer.

Syntax

DellString

Access

Read-only

PCI Device Description Name
Name

pCIDeviceDescriptionName

Object ID

1.3.6.1.4.1.674.10892.1.1100.80.1.9

Description

Defines the descriptive name of the PCI device.

Syntax

DellString

Access

Read-only

Device Group

301

PCI Device Speed
Name

pCIDeviceSpeed

Object ID

1.3.6.1.4.1.674.10892.1.1100.80.1.10

Description

Defines the bus speed in MHz of the PCI device in this chassis.
A zero (0) indicates that the speed is unknown.

Syntax

DellUnsigned32BitRange

Access

Read-only

PCI Device Adapter Fault
Name

pCIDeviceAdapterFault

Object ID

1.3.6.1.4.1.674.10892.1.1100.80.1.11

Description

Defines whether the PCI device in this chassis has detected a fault.

Syntax

DellBoolean

Access

Read-only

PCI Device Configuration Space Table
Name

pCIDeviceConfigurationSpaceTable

Object ID

1.3.6.1.4.1.674.10892.1.1100.82

Description

Defines the PCI Device Configuration Table.

Syntax

SEQUENCE OF PCIDeviceConfigurationSpaceTableEntry

Access

Not accessible

PCI Device Configuration Space Table Entry
Name

pCIDeviceConfigurationSpaceTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.1100.82.1

Description

Defines the PCI Device Configuration Table entry.

Syntax

PCIDeviceConfigurationSpaceTableEntry

Access

Not accessible

Index

pCIDeviceConfigurationSpacechassisIndex,
pCIDeviceConfigurationSpaceIndex

302

Device Group

PCI Device Configuration Space Chassis Index
Name

pCIDeviceConfigurationSpacechassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.1100.82.1.1

Description

Defines the index (one-based) of this chassis.

Syntax

DellObjectRange

Access

Read-only

PCI Device Configuration Space Index
Name

pCIDeviceConfigurationSpaceIndex

Object ID

1.3.6.1.4.1.674.10892.1.1100.82.1.2

Description

Defines the index (one-based) of the PCI device configuration
in this chassis.

Syntax

DellObjectRange

Access

Read-only

PCI Device Configuration Space State Capabilities
Name

pCIDeviceConfigurationSpaceStateCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.1100.82.1.3

Description

Defines the capabilities of the PCI device configuration.

Syntax

DellStateCapabilities

Access

Read-only

PCI Device Configuration Space State Settings
Name

pCIDeviceConfigurationSpaceStateSettings

Object ID

1.3.6.1.4.1.674.10892.1.1100.82.1.4

Description

Defines the state of the PCI device configuration.

Syntax

DellStateSettings

Access

Read-write

Device Group

303

PCI Device Configuration Space Status
Name

pCIDeviceConfigurationSpaceStatus

Object ID

1.3.6.1.4.1.674.10892.1.1100.82.1.5

Description

Defines the status of the PCI device configuration.

Syntax

DellStatus

Access

Read-only

PCI Device Index Reference
Name

pCIDeviceIndexReference

Object ID

1.3.6.1.4.1.674.10892.1.1100.82.1.6

Description

Defines the index number of PCI device that this configuration
applies to.

Syntax

DellObjectRange

Access

Read-only

PCI Device Configuration Space Bus Number
Name

pCIDeviceConfigurationSpaceBusNumber

Object ID

1.3.6.1.4.1.674.10892.1.1100.82.1.7

Description

Defines the bus number of the PCI device configuration in this
chassis.

Syntax

DellUnsigned32BitRange

Access

Read-only

PCI Device Configuration Space Device Number
Name

pCIDeviceConfigurationSpaceDeviceNumber

Object ID

1.3.6.1.4.1.674.10892.1.1100.82.1.8

Description

Defines the device number of the PCI device in this chassis.

Syntax

DellUnsigned32BitRange

Access

Read-only

304

Device Group

PCI Device Configuration Space Function Number
Name

pCIDeviceConfigurationSpaceFunctionNumber

Object ID

1.3.6.1.4.1.674.10892.1.1100.82.1.9

Description

Defines the function number of the PCI device in this chassis.

Syntax

DellUnsigned32BitRange

Access

Read-only

PCI Device Configuration Space Header
Name

pCIDeviceConfigurationSpaceHeader

Object ID

1.3.6.1.4.1.674.10892.1.1100.82.1.10

Description

Defines the common configuration space header of the PCI device.

Syntax

Octet String (SIZE(0..1025))

Access

Read-only

Network Device Table
Name

networkDeviceTable

Object ID

1.3.6.1.4.1.674.10892.1.1100.90

Description

Defines the Network Device Table.

Syntax

SEQUENCE OF NetworkDeviceTableEntry

Access

Not accessible

Network Device Table Entry
Name

networkDeviceTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.1100.90.1

Description

Defines the Network Device Table Entry.

Syntax

NetworkDeviceTableEntry

Access

Not accessible

Index

networkDeviceChassisIndex, networkDeviceIndex

Device Group

305

Network Device Chassis Index
Name

networkDeviceChassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.1100.90.1.1

Description

Defines the index (one-based) of the chassis that contains the
network device.

Syntax

DellObjectRange

Access

Read-only

Network Device Index
Name

networkDeviceIndex

Object ID

1.3.6.1.4.1.674.10892.1.1100.90.1.2

Description

Defines the index (one-based) of the network device.

Syntax

DellObjectRange

Access

Read-only

Network Device Status
Name

networkDeviceStatus

Object ID

1.3.6.1.4.1.674.10892.1.1100.90.1.3

Description

Defines the status of the network device.

Syntax

DellStatus

Access

Read-only

Network Device Connection Status
Name

networkDeviceConnectionStatus

Object ID

1.3.6.1.4.1.674.10892.1.1100.90.1.4

Description

Defines the connection status of the network device.

Syntax

DellNetworkDeviceConnectionStatus (see Table 14-20)

Access

Read-only

306

Device Group

Network Device Description Name
Name

networkDeviceDescriptionName

Object ID

1.3.6.1.4.1.674.10892.1.1100.90.1.5

Description

Defines the description of the network device.

Syntax

DellString

Access

Read-only

Network Device Product Name
Name

networkDeviceProductName

Object ID

1.3.6.1.4.1.674.10892.1.1100.90.1.6

Description

Defines the product name of the network device.

Syntax

DellString

Access

Read-only

Network Device Vendor Name
Name

networkDeviceVendorName

Object ID

1.3.6.1.4.1.674.10892.1.1100.90.1.7

Description

Defines the name of the vendor of the network device.

Syntax

DellString

Access

Read-only

Network Device Service Name
Name

networkDeviceServiceName

Object ID

1.3.6.1.4.1.674.10892.1.1100.90.1.8

Description

Defines the service name of the network device.

Syntax

DellString

Access

Read-only

Device Group

307

Network Device Driver Image Path Name
Name

networkDeviceDriverImagePathName

Object ID

1.3.6.1.4.1.674.10892.1.1100.90.1.9

Description

Defines the path to the binary image of the driver for the
network device.

Syntax

DellString

Access

Read-only

Network Device Driver Version Name
Name

networkDeviceDriverVersionName

Object ID

1.3.6.1.4.1.674.10892.1.1100.90.1.10

Description

Defines the version of the driver for the network device.

Syntax

DellString

Access

Read-only

Network Device IP Address
Name

networkDeviceIPAddress

Object ID

1.3.6.1.4.1.674.10892.1.1100.90.1.11

Description

Defines the IP address of the network device.

Syntax

IpAddress

Access

Read-only

Network Device IP Subnet Mask
Name

networkDeviceIPSubnetMask

Object ID

1.3.6.1.4.1.674.10892.1.1100.90.1.12

Description

Defines the IP subnet mask for the IP address currently assigned
to the network device.

Syntax

IpAddress

Access

Read-only

308

Device Group

Network Device Default Gateway IP Address
Name

networkDeviceDefaultGatewayIPAddress

Object ID

1.3.6.1.4.1.674.10892.1.1100.90.1.13

Description

Defines the IP address of the default gateway for the network device.

Syntax

IpAddress

Access

Read-only

Network Device DHCP Server IP Address
Name

networkDeviceDHCPServerIPAddress

Object ID

1.3.6.1.4.1.674.10892.1.1100.90.1.14

Description

Defines the IP address of the DHCP server that was used to
obtain the IP address of the network device if DHCP was used
to configure the network device.

Syntax

IpAddress

Access

Read-only

Network Device Current MAC Address
Name

networkDeviceCurrentMACAddress

Object ID

1.3.6.1.4.1.674.10892.1.1100.90.1.15

Description

Defines the current MAC address of the network device.

Syntax

DellMACAddress

Access

Read-only

Network Device Permanent MAC Address
Name

networkDevicePermanentMACAddress

Object ID

1.3.6.1.4.1.674.10892.1.1100.90.1.16

Description

Defines the permanent MAC address of the network device.

Syntax

DellMACAddress

Access

Read-only

Device Group

309

Network Device PCI Bus Number
Name

networkDevicePCIBusNumber

Object ID

1.3.6.1.4.1.674.10892.1.1100.90.1.17

Description

Defines the PCI bus number of the network device.

Syntax

DellUnsigned8BitRange

Access

Read-only

Network Device PCI Device Number
Name

networkDevicePCIDeviceNumber

Object ID

1.3.6.1.4.1.674.10892.1.1100.90.1.18

Description

Defines the PCI device number of the network device.

Syntax

DellUnsigned8BitRange

Access

Read-only

Network Device PCI Function Number
Name

networkDevicePCIFunctionNumber

Object ID

1.3.6.1.4.1.674.10892.1.1100.90.1.19

Description

Defines the PCI function number of the network device.

Syntax

DellUnsigned8BitRange

Access

Read-only

Network Device IRQ
Name

networkDeviceIRQ

Object ID

1.3.6.1.4.1.674.10892.1.1100.90.1.20

Description

Defines the interrupt request number of the network device.

Syntax

DellUnsigned32BitRange

Access

Read-only

310

Device Group

Network Device Base IO Port Address
Name

networkDeviceBaseIOPortAddress

Object ID

1.3.6.1.4.1.674.10892.1.1100.90.1.21

Description

Defines the base input/outport port address of the network device.

Syntax

DellUnsigned32BitRange

Access

Read-only

Network Device Teaming Flags
Name

networkDeviceTeamingFlags

Object ID

1.3.6.1.4.1.674.10892.1.1100.90.1.22

Description

Defines the teaming features of the network device.

Syntax

DellNetworkDeviceTeamingFlags (see Table 14-21)

Access

Read-only

Network Device TOE Capability Flags
Name

networkDeviceTOECapabilityFlags

Object ID

1.3.6.1.4.1.674.10892.1.1100.90.1.23

Description

Defines the TCP/IP Offload Engine (TOE) capability flags of
the network device.

Syntax

DellNetworkDeviceTOECapabilityFlags (see Table 14-22)

Access

Read-only

Network Device TOE Enabled
Name

networkDeviceTOEEnabled

Object ID

1.3.6.1.4.1.674.10892.1.1100.90.1.24

Description

Defines if TOE is enabled for the network device.

Syntax

DellBoolean

Access

Read-only

Device Group

311

Network Device RDMA Capability Flags
Name

networkDeviceRDMACapabilityFlags

Object ID

1.3.6.1.4.1.674.10892.1.1100.90.1.25

Description

Defines the Remote Direct Memory Access (RDMA) capability
flags of the network device.

Syntax

DellNetworkDeviceRDMACapabilityFlags (see Table 14-23)

Access

Read-only

Network Device RDMA Enabled
Name

networkDeviceRDMAEnabled

Object ID

1.3.6.1.4.1.674.10892.1.1100.90.1.26

Description

Defines if RDMA is enabled for the network device.

Syntax

DellBoolean

Access

Read-only

Network Device iSCSI Capability Flags
Name

networkDeviceiSCSICapabilityFlags

Object ID

1.3.6.1.4.1.674.10892.1.1100.90.1.27

Description

Defines the Internet Small Computer System Interface (iSCSI)
capability flags of the network device.

Syntax

DellNetworkDeviceiSCSICapabilityFlags (see Table 14-24)

Access

Read-only

Network Device iSCSI Enabled
Name

networkDeviceiSCSIEnabled

Object ID

1.3.6.1.4.1.674.10892.1.1100.90.1.28

Description

Defines if iSCSI is enabled for the network device.

Syntax

DellBoolean

Access

Read-only

312

Device Group

Managed System Services Device Table
Name

managedSystemServicesDeviceTable

Object ID

1.3.6.1.4.1.674.10892.1.1100.100

Description

Defines the Managed System Services Device Table.

Syntax

Sequence of ManagedSystemServicesDeviceTable

Access

Not accessible

Managed System Services Device Table Entry
Name

managedSystemServicesDeviceTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.1100.100.1

Description

Defines the managed system services device table entry.

Syntax

ManagedSystemServicesDeviceTableEntry

Access

Not accessible

Index

managedSystemServicesDeviceChassisIndex,
managedSystemServicesDeviceIndex

Managed System Services Device Chassis Index
Name

managedSystemServicesDeviceChassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.1100.100.1.1

Description

Defines the index (one-based) of the chassis that contains the
managed system services device.

Syntax

DellObjectRange

Access

Read-only

Device Group

313

Managed System Services Device Index
Name

managedSystemServicesDeviceIndex

Object ID

1.3.6.1.4.1.674.10892.1.1100.100.1.2

Description

Defines the index (one-based) of the managed system services
device.

Syntax

DellObjectRange

Access

Read-only

Managed System Services Device Status
Name

managedSystemServicesDeviceStatus

Object ID

1.3.6.1.4.1.674.10892.1.1100.100.1.3

Description

Defines the status of the managed system services device.

Syntax

DellStatus

Access

Read-only

Managed System Services Device Type
Name

managedSystemServicesDeviceType

Object ID

1.3.6.1.4.1.674.10892.1.1100.100.1.4

Description

Defines the type of the managed system services device.

Syntax

DellManagedSystemServicesDeviceType. See Table 14-25

Access

Read-only

314

Device Group

Managed System Services Device Storage Present
Name

managedSystemServicesDeviceStoragePresent

Object ID

1.3.6.1.4.1.674.10892.1.1100.100.1.5

Description

Defines whether storage is present on the managed system
services device.

Syntax

DellBoolean

Access

Read-only

Managed System Services Device Storage Size
Name

managedSystemServicesDeviceStorageSize

Object ID

1.3.6.1.4.1.674.10892.1.1100.100.1.6

Description

Defines the size in Megabytes (MB) of the storage present on
the managed system services device.

Syntax

DellUnsigned32BitRange

Access

Read-only

SD Card Unit Table
Name

sdCardUnitTable

Object ID

1.3.6.1.4.1.674.10892.1.1100.110

Description

Defines the SD Card Unit Table.

Syntax

SEQUENCE OF SdCardUnitTableEntry

Access

Not accessible

SD Card Unit Table Entry
Name

sdCardUnitTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.1100.110.1

Description

Defines the SD Card Unit Table Entry.

Syntax

SdCardUnitTableEntry

Access

Not accessible

Device Group

315

Name

sdCardUnitTableEntry

Index

sdCardUnitChassisIndex,
sdCardUnitIndex

SD Card Unit Chassis Index
Name

sdCardUnitChassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.1100.110.1.1

Description

Defines the index (one-based) of the chassis that contains the
SD Card unit.

Syntax

DellObjectRange

Access

Read-only

SD Card Unit Index
Name

sdCardUnitIndex

Object ID

1.3.6.1.4.1.674.10892.1.1100.110.1.2

Description

Defines the index (one-based) of the SD Card unit.

Syntax

DellObjectRange

Access

Read-only

SD Card Unit State Capabilities
Name

sdCardUnitStateCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.1100.110.1.3

Description

Defines the state capabilities of the SD Card unit.

Syntax

DellStateCapabilities

Access

Read-only

SD Card Unit State Settings
Name

sdCardUnitStateSettings

Object ID

1.3.6.1.4.1.674.10892.1.1100.110.1.4

316

Device Group

Name

sdCardUnitStateSettings

Description

Defines the state settings of the SD Card unit.

Syntax

DellStateSettings

Access

Read-only

SD Card Unit Redundancy Status
Name

sdCardUnitRedundancyStatus

Object ID

1.3.6.1.4.1.674.10892.1.1100.110.1.5

Description

Defines the redundancy status of the SD Card unit.

Syntax

DellStatusRedundancy

Access

Read-only

SD Card Unit Count For Redundancy
Name

sdCardUnitCountForRedundancy

Object ID

1.3.6.1.4.1.674.10892.1.1100.110.1.6

Description

Defines the total number of SD Card devices required for this
SD Card unit to have full redundancy.

Syntax

DellObjectRange

Access

Read-only

SD Card Unit Name
Name

sdCardUnitName

Object ID

1.3.6.1.4.1.674.10892.1.1100.110.1.7

Description

Defines the name of the SD Card unit.

Syntax

DellString

Access

Read-only

Device Group

317

SD Card Unit Status
Name

sdCardUnitStatus

Object ID

1.3.6.1.4.1.674.10892.1.1100.110.1.8

Description

Defines the status of the SD Card unit.

Syntax

DellStatus

Access

Read-only

SD Card Device Table
Name

sdCardDeviceTable

Object ID

1.3.6.1.4.1.674.10892.1.1100.112

Description

Defines the SD Card Device Table.

Syntax

SEQUENCE OF SdCardDeviceTableEntry

Access

Not accessible

SD Card Device Table Entry
Name

sdCardDeviceTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.1100.112.1

Description

Defines the SD Card Device Table Entry.

Syntax

SdCardDeviceTableEntry

Access

Not accessible

Index

sdCardDeviceChassisIndex,
sdCardDeviceIndex

SD Card Device Chassis Index
Name

sdCardDeviceChassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.1100.112.1.1

Description

Defines the index (one-based) of the chassis that contains the
SD Card device.

Syntax

DellObjectRange

318

Device Group

Name

sdCardDeviceChassisIndex

Access

Read-only

SD Card Device Index
Name

sdCardDeviceIndex

Object ID

1.3.6.1.4.1.674.10892.1.1100.112.1.2

Description

Defines the index (one-based) of the SD Card device.

Syntax

DellObjectRange

Access

Read-only

SD Card Device Status
Name

sdCardDeviceStatus

Object ID

1.3.6.1.4.1.674.10892.1.1100.112.1.3

Description

Defines the status of the SD Card device.

Syntax

DellStatus

Access

Read-only

SD Card Device Type
Name

sdCardDeviceType

Object ID

1.3.6.1.4.1.674.10892.1.1100.112.1.4

Description

Defines the type of the SD Card device.

Syntax

DellSDCardDeviceType

Access

Read-only

SD Card Device Config Capabilities
Name

sdCardDeviceConfigCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.1100.112.1.5

Description

Defines the configuration capabilities of the SD Card device.

Syntax

DellSDCardDeviceConfigCapabilities

Device Group

319

Name

sdCardDeviceConfigCapabilities

Access

Read-only

SD Card Device Config Settings
Name

sdCardDeviceConfigSettings

Object ID

1.3.6.1.4.1.674.10892.1.1100.112.1.6

Description

Defines the configuration settings of the SD Card device.

Syntax

DellSDCardDeviceConfigSettings

Access

Read-only

SD Card Device Location Name
Name

sdCardDeviceLocationName

Object ID

1.3.6.1.4.1.674.10892.1.1100.112.1.7

Description

Defines the location of the SD Card device.

Syntax

DellString

Access

Read-only

SD Card Device Card Present
Name

sdCardDeviceCardPresent

Object ID

1.3.6.1.4.1.674.10892.1.1100.112.1.8

Description

Defines whether the SD Card is present for the SD Card device.

Syntax

DellBoolean

Access

Read-only

SD Card Device Card State
Name

sdCardDeviceCardState

Object ID

1.3.6.1.4.1.674.10892.1.1100.112.1.9

Description

Defines the state of the SD Card.

Syntax

DellSDCardDeviceCardState

320

Device Group

Name

sdCardDeviceCardState

Access

Read-only

SD Card Device Card Storage Size
Name

sdCardDeviceCardStorageSize

Object ID

1.3.6.1.4.1.674.10892.1.1100.112.1.10

Description

Defines the storage size in MB (megabytes) of the SD card for
the SD Card device.

Syntax

DellUnsigned32BitRange

Access

Read-only

SD Card Device Unit Index Reference
Name

sdCardDeviceUnitIndexReference

Object ID

1.3.6.1.4.1.674.10892.1.1100.112.1.11

Description

Defines the index to the associated SD Card unit if the SD Card
device is part of a SD Card unit.

Syntax

DellObjectRange

Access

Read-only

Device Group

321

SD Card Device Card Available Storage Size
Name

sdCardDeviceCardAvailableStorageSize

Object ID

1.3.6.1.4.1.674.10892.1.1100.112.1.12

Description

Defines the available storage size in MB (megabytes) of the SD
card for the SD card device.

Syntax

DellSigned32BitRange

Access

Read-only

SD Card Device Card Licensed
Name

sdCardDeviceCardLicensed

Object ID

1.3.6.1.4.1.674.10892.1.1100.112.1.13

Description

Defines whether the SD card is licensed by the system vendor.

Syntax

DellSDCardDeviceCardLicensed

Access

Read-only

Device Group Variable Values
This section includes definitions for server administrator-specific variable
values used in this section.
Table 14-1. Pointing Device Type
Variable Name: DellPointingDeviceType
Data Type: Integer
Possible Data Values

Meaning of Data Value

deviceTypeIsOther(1)

Device type is not one of the following:

deviceTypeIsUnknown(2)

Device type is unknown.

deviceTypeIsAMouse(3)

Device type is a mouse.

deviceTypeIsATrackBall(4)

Device type is a track ball.

deviceTypeIsATrackPoint(5)

Device type is a track point.

deviceTypeIsAGlidePoint(6)

Device type is a glide point.

322

Device Group

Table 14-1.

Pointing Device Type (continued)

Variable Name: DellPointingDeviceType
Data Type: Integer
Possible Data Values

Meaning of Data Value

deviceTypeIsATouchPad(7)

Device type is a touch pad.

Table 14-2.

Processor Device Status State

Variable Name: DellProcessorDeviceStatusState
Data Type: Integer
Possible Data Values

Meaning of Data Value

other(1)

Processor device type is not one of the
following:

unknown(2)

Device type is unknown.

enabled(3)

Device is enabled.

userDisabled(4)

Device is disabled by the user.

biosDisabled(5)

Device has its BIOS disabled.

idle(6)

Device is idle.

Table 14-3.

Processor Device Status Reading

Variable Name: DellProcessorDeviceStatusReading
Data Type: Integer

NOTE: These values are bit masks, so combination values are possible.
Possible Data Values

Meaning of Data Value

internalError(1)

The processor experienced an internal
error

thermalTrip(2)

The processor experienced a thermal trip

configurationError(32)

The processor experienced a configuration
error

processorPresent(128)

The processor is present

Device Group

323

Table 14-3. Processor Device Status Reading (continued)
Variable Name: DellProcessorDeviceStatusReading
Data Type: Integer

NOTE: These values are bit masks, so combination values are possible.
Possible Data Values

Meaning of Data Value

processorDisabled(256)

The processor is disabled

terminatorPresent(512)

The terminator is Present

processorThrottled(1024)

The processor is throttled

Table 14-4. Processor Device Type
Variable Name: DellProcessorDeviceType
Data Type: Integer
Possible Data Values

Meaning of Data Value

deviceTypeIsOther(1)

The processor device type is not one
of the following values:

deviceTypeIsUnknown(2)

The processor device type is
unknown.

deviceTypeIsCPU(3)

The processor device type is a central
processing unit.

deviceTypeIsMathProcessor(4)

The processor device type is a math
processor.

deviceTypeIsDSP(5)

The processor device type is a digital
signal processor.

deviceTypeIsAVideoProcessor(6)

The processor device is a video
processor.

324

Device Group

Table 14-5.

Processor Upgrade Information

Variable Name: DellProcessorUpgradeInformation
Data Type: Integer
Possible Data Values

Meaning of Data Value

processorUpgradeIsOther(1)

The upgrade device type is
not one of the following:

processorUpgradeIsUnknown(2)

Upgrade device type is
unknown.

processorUpgradeIsByDaughterBoard(3)

Upgrade device is on a
daughter board.

processorUpgradeIsByZIFSocket(4)

Upgrade device is in a zero
insertion force (ZIF) socket.

processorUpgradeIsByReplacement(5)

Upgrade device is a
replacement.

processorUpgradeIsNone(6)

There is no upgrade device.

processorUpgradeIsByLIFSocket(7)

Upgrade device is in a low
insertion force (LIF) socket.

processorUpgradeIsBySlot1(8)

Upgrade device is a SLOT 1
processor.

processorUpgradeIsBySlot2(9)

Upgrade device is a SLOT 2
processor.

processorUpgradeIsBy370PinSocket(10)

Upgrade device is a 370 pin
socket.

processorUpgradeIsBySlotA(11)

Upgrade is by Slot A.

processorUpgradeIsBySlotM(12)

Upgrade is by Slot M.

processorUpgradeIsByScoket423(13)

Upgrade is by Socket 423.

processorUpgradeIsBySocketA(14)

Upgrade is by Socket A
(Socket 462).

processorUpgradeIsBySocket478(15)

Upgrade is by Socket 478.

processorUpgradeIsBySocket754(16)

Upgrade is by Socket 754.

processorUpgradeIsBySocket940(17)

Upgrade is by Socket 940.

Device Group

325

Table 14-5. Processor Upgrade Information (continued)
Variable Name: DellProcessorUpgradeInformation
Data Type: Integer
Possible Data Values

Meaning of Data Value

processorUpgradeIsBySocket939(18)

Upgrade is by Socket 939.

processorUpgradeIsBySocketmPGA604(19) Upgrade is by Socket
mPGA604.
processorUpgradeIsBySocketLGA771(20)

Upgrade is by Socket
LGA771.

processorUpgradeIsBySocketLGA775(21)

Upgrade is by Socket
LGA775.

processorUpgradeIsBySocketS1(22)

Upgrade is by Socket S1.

processorUpgradeIsBySocketAM2(23)

Upgrade is by Socket AM2.

processorUpgradeIsBySocketF(24)

Upgrade is by Socket F
(1207).

processorUpgradeIsBySocketLGA1366(25) Upgrade is by Socket
LGA1366.
Table 14-6. Processor Device Family
Variable Name: DellProcessorDeviceFamily
Data Type: Integer
Possible Data Values

Meaning of Data Value

deviceFamilyIsOther(1)

The processor family is not one of the
following values.

deviceFamilyIsUnknown(2)

The processor family is unknown.

deviceFamilyIs8086(3)

The processor family is 8086.

deviceFamilyIs80286(4)

The processor family is 80286.

deviceFamilyIs80386(5)

The processor family is 80386.

deviceFamilyIs80486(6)

The processor family is 80486.

deviceFamilyIS8087(7)

The processor family is 8087.

326

Device Group

Table 14-6.

Processor Device Family (continued)

Variable Name: DellProcessorDeviceFamily
Data Type: Integer
Possible Data Values

Meaning of Data Value

deviceFamilyIs80287(8)

The processor family is 80287.

deviceFamilyIs80387(9)

The processor family is 80387.

deviceFamilyIs80487(10)

The processor family is 80487.

deviceFamilyIsPentium(11)

The processor family is Intel Pentium.

deviceFamilyIsPentiumPro(12)

The processor family is Pentium Pro.

deviceFamilyIsPentium2(13)

The processor family is Pentium II.

deviceFamilyIsPentiumMMX(14)

The processor family is Pentium MMX.

deviceFamilyIsCeleron(15)

The processor family is Celeron.

deviceFamilyIsXeon(16)

The processor family is Xeon.

deviceFamilyIsPentium3(17)

The processor family is Pentium III.

deviceFamilyIsPentium3Xeon(18) The processor family is Pentium III
Xeon.
deviceFamilyIsPentium3Step(19) The processor family is Pentium III
Speed Step.
deviceFamilyIsPentiumItanium
(20)

The processor family is Itanium.

deviceFamilyIsIntelXeon(21)

The processor family is Intel Xeon.

deviceFamilyIsPentium4(22)

The processor family is Pentium 4.

deviceFamilyIsIntelXeonMP(23)

The processor family is Intel Xeon MP.

deviceFamilyIsIntelItanium2(24) The processor family is Intel Itanium 2.
deviceFamilyIsK5(25)

The processor family is K5.

deviceFamilyIsK6(26)

The processor family is K6.

deviceFamilyIsK6-2(27)

The processor family is K6-2.

deviceFamilyIsK6-3(28)

The processor family is K6-3.

deviceFamilyIsAMDAthlon(29)

The processor family is AMD Athlon.

deviceFamilyIsAMD2900(30)

The processor family is AMD2900.
Device Group

327

Table 14-6. Processor Device Family (continued)
Variable Name: DellProcessorDeviceFamily
Data Type: Integer
Possible Data Values

Meaning of Data Value

deviceFamilyIsK6-2Plus(31)

The processor family is K6-2+.

deviceFamilyIsPowerPC(32)

The processor family is Power PC.

deviceFamilyIsPowerPC601(33)

The processor family is Power PC 601.

deviceFamilyIsPowerPC603(34)

The processor family is Power PC 603.

deviceFamilyIsPowerPC603Plus
(35)

The processor family is Power PC
603+.

deviceFamilyIsPowerPC604(36)

The processor family is Power PC 604.

deviceFamilyIsPowerPC620(37)

The processor family is Power PC 620.

deviceFamilyIsPowerPCx704(38)

The processor family is Power PC x704.

deviceFamilyIsPowerPC750(39)

The processor family is Power PC 750.

deviceFamilyIsIntelCoreDuo(40) The processor family is Intel Core Duo.
deviceFamilyIsIntelCoreDuoMobi The processor family is Intel Core Duo
le(41)
mobile.
deviceFamilyIsIntelCoreSoloMob The processor family is Intel Core Solo
ile(42)
mobile.
deviceFamilyIsIntelAtom(43)

The processor family is Intel Atom.

deviceFamilyIsAlpha(48)

The processor family is Alpha.

deviceFamilyIsAlpha21064(49)

The processor family is Alpha 21064.

deviceFamilyIsAlpha21066(50)

The processor family is Alpha 21066.

deviceFamilyIsAlpha21164(51)

The processor family is Alpha 21164.

deviceFamilyIsAlpha21164PC(52) The processor family is Alpha
21164PC.
deviceFamilyIsAlpha21164a(53)

The processor family is Alpha 21164a.

deviceFamilyIsAlpha21264(54)

The processor family is Alpha 21264.

deviceFamilyIsAlpha21364(55)

The processor family is Alpha 21364.

328

Device Group

Table 14-6.

Processor Device Family (continued)

Variable Name: DellProcessorDeviceFamily
Data Type: Integer
Possible Data Values

Meaning of Data Value

deviceFamilyIsAMDTurionIIUltra The processor family is AMD Turion II
DualMobileM(56)
Ultra Dual-Core Mobile M Processor
Family.
deviceFamilyIsAMDTurionIIDualM The processor family is AMD Turion II
obileM(57)
Dual-Core Mobile M Processor Family.
deviceFamilyIsAMDAthlonIIDualM The processor family is AMD Athlon II
obileM(58)
Dual-Core Mobile M Processor Family.
deviceFamilyIsAMDOpteron6100
(59)

The processor family is AMD Opteron
6100 Series Processor.

deviceFamilyIsAMDOpteron4100
(60)

The processor family is AMD Opteron
4100 Series Processor.

deviceFamilyIsAMDOpteron6200
(61)

The processor family is AMD Opteron
6200 Series Processor.

deviceFamilyIsAMDOpteron4200
(62)

The processor family is AMD Opteron
4200 Series Processor.

deviceFamilyIsMIPS(64)

The processor family is MIPS.

deviceFamilyIsMIPSR4000(65)

The processor family is MIPS R4000.

deviceFamilyIsMIPSR4200(66)

The processor family is MIPS R4200.

deviceFamilyIsMIPSR4400(67)

The processor family is MIPS R4400.

deviceFamilyIsMIPSR4600(68)

The processor family is MIPS R4600.

deviceFamilyIsMIPSR10000(69)

The processor family is MIPS R10000.

deviceFamilyIsSPARC(80)

The processor family is SPARC.

deviceFamilyIsSuperSPARC(81)

The processor family is SuperSPARC.

deviceFamilyIsmicroSPARCII(82) The processor family is microSPARC II.
deviceFamilyIsmicroSPARCIIep
(83)

The processor family is microSPARC
IIep.

deviceFamilyIsUltraSPARC(84)

The processor family is UltraSPARC.

deviceFamilyIsUltraSPARCII(85) The processor family is UltraSPARC II.
Device Group

329

Table 14-6. Processor Device Family (continued)
Variable Name: DellProcessorDeviceFamily
Data Type: Integer
Possible Data Values

Meaning of Data Value

deviceFamilyIsUltraSPARCIIi(86) The processor family is UltraSPARC IIi.
deviceFamilyIsUltraSPARCIII(87) The processor family is UltraSPARC
III.
deviceFamilyIsUltraSPARCIIIi
(88)

The processor family is UltraSPARC
IIIi.

deviceFamilyIs68040(96)

The processor family is 68040 Family.

deviceFamilyIs68xxx(97)

The processor family is 68xxx.

deviceFamilyIs68000(98)

The processor family is 68000.

deviceFamilyIs68010(99)

The processor family is 68010.

deviceFamilyIs68020(100)

The processor family is 68020.

deviceFamilyIs68030(101)

The processor family is 68030.

deviceFamilyIsHobbit(112)

The processor family is Hobbit.

deviceFamilyIsCrusoe5000(120)

The processor family is Crusoe 5000.

deviceFamilyIsCrusoe3000(121)

The processor family is Crusoe 3000.

deviceFamilyIsEfficeon8000
(122)

The processor family is Efficeon 8000.

deviceFamilyIsWeitek(128)

The processor family is Weitek.

deviceFamilyIsIntelCeleronM(13 The processor family is Intel Celeron
0)
M.
deviceFamilyIsAMDAthlon64(131) The processor family is AMD Athlon
64.
deviceFamilyIsAMDOpteron(132)

The processor family is AMD Opteron.

deviceFamilyIsAMDSempron(133)

The processor family is AMD Sempron.

deviceFamilyIsAMDTurion64Mobile The processor family is AMD Turion 64
(134)
Mobile Technology.
deviceFamilyIsDualCoreAMDOpter The processor family is Dual-Core
on(135)
AMD Opteron.

330

Device Group

Table 14-6.

Processor Device Family (continued)

Variable Name: DellProcessorDeviceFamily
Data Type: Integer
Possible Data Values

Meaning of Data Value

deviceFamilyIsAMDAthlon64X2Dual The processor family is AMD Athlon
Core(136)
64 X2 Dual-Core.
deviceFamilyIsAMDTurion64X2Mob The processor family is AMD Turion 64
ile(137)
X2 Mobile Technology.
deviceFamilyIsQuadCoreAMDOpter The processor family is Quad-Core
on(138)
AMD Opteron.
deviceFamilyIsThirdGeneration
AMDOpteron(139)

The processor family is thirdgeneration AMD Opteron.

deviceFamilyIsAMDPhenomFXQuadC The processor family is AMD Phenom
ore(140)
FX Quad-Core.
deviceFamilyIsAMDPhenomX4QuadC The processor family is AMD Phenom
ore(141)
X4 Quad-Core.
deviceFamilyIsAMDPhenomX2DualC The processor family is AMD Phenom
ore(142)
X2 Dual-Core.
deviceFamilyIsAMDAthlonX2DualC The processor family is AMD Athlon
ore(143)
X2 Dual-Core.
deviceFamilyIsPA-RISC(144)

The processor family is PA-RISC.

deviceFamilyIsPA-RISC8500(145) The processor family is PA-RISC 8500.
deviceFamilyIsPA-RISC8000(146) The processor family is PA-RISC 8000.
deviceFamilyIsPARISC7300LC(147)

The processor family is PA-RISC
7300LC.

deviceFamilyIsPA-RISC7200(148) The processor family is PA-RISC 7200.
deviceFamilyIsPARISC7100LC(149)

The processor family is PA-RISC
7100LC.

deviceFamilyIsPA-RISC7100(150) The processor family is PA-RISC 7100.
deviceFamilyIsV30(160)

The processor family is V30.

deviceFamilyIsQuadCoreIntelXeo The processor family is Quad-Core
n3200(161)
Intel Xeon processor 3200 Series.

Device Group

331

Table 14-6. Processor Device Family (continued)
Variable Name: DellProcessorDeviceFamily
Data Type: Integer
Possible Data Values

Meaning of Data Value

deviceFamilyIsDualCoreIntelXeo The processor family is Dual-Core Intel
n3000(162)
Xeon processor 3000 Series.
deviceFamilyIsQuadCoreIntelXeo The processor family is Quad-Core
n5300(163)
Intel Xeon processor 5300 Series.
deviceFamilyIsDualCoreIntelXeo The processor family is Dual-Core Intel
n5100(164)
Xeon processor 5100 Series.
deviceFamilyIsDualCoreIntelXeo The processor family is Dual-Core Intel
n5000(165)
Xeon processor 5000 Series.
deviceFamilyIsDualCoreIntelXeo The processor family is Dual-Core Intel
nLV(166)
Xeon processor LV.
deviceFamilyIsDualCoreIntelXeo The processor family is Dual-Core Intel
nULV(167)
Xeon processor ULV.
deviceFamilyIsDualCoreIntelXeo The processor family is Dual-Core Intel
n7100(168)
Xeon processor 7100 Series.
deviceFamilyIsQuadCoreIntelXeo The processor family is Quad-Core
n5400(169)
Intel Xeon processor 5400 Series.
deviceFamilyIsQuadCoreIntelXeo The processor family is Quad-Core
n(170)
Intel Xeon.
deviceFamilyIsDualCoreIntelXeo The processor family is Dual-Core Intel
n5200(171)
Xeon processor 5200 Series.
deviceFamilyIsDualCoreIntelXeo The processor family is Dual-Core Intel
n7200(172)
Xeon processor 7200 Series.
deviceFamilyIsQuadCoreIntelXeo The processor family is Quad-Core
n7300(173)
Intel Xeon processor 7300 Series.
deviceFamilyIsQuadCoreIntelXeo The processor family is Quad-Core
n7400(174)
Intel Xeon processor 7400 Series.
deviceFamilyIsMultiCoreIntelXe The processor family is Multi-Core
on7400(175)
Intel Xeon processor 7400 Series.
deviceFamilyIsM1(176)

332

Device Group

The processor family is M1.

Table 14-6.

Processor Device Family (continued)

Variable Name: DellProcessorDeviceFamily
Data Type: Integer
Possible Data Values

Meaning of Data Value

deviceFamilyIsM2(177)

The processor family is M2.

deviceFamilyIsIntelPentium4HT
(179)

The processor family is Intel Pentium 4
HT processor.

deviceFamilyIsAS400(180)

The processor family is AS400.

deviceFamilyIsAMDAthlonXP(182) The processor family is AMD Athlon
XP.
deviceFamilyIsAMDAthlonMP(183) The processor family is AMD Athlon
MP.
deviceFamilyIsAMDDuron(184)

The processor family is AMD Duron.

deviceFamilyIsIntelPentiumM(185) The processor family is Intel Pentium M.
deviceFamilyIsIntelCeleronD(186) The processor family is Intel Celeron
D.
deviceFamilyIsIntelPentiumD(187) The processor family is Intel Pentium
D.
deviceFamilyIsIntelPentiumExtr The processor family is Intel Pentium
eme(188)
Processor Extreme Edition.
deviceFamilyIsIntelCoreSolo
(189)

The processor family is Intel Core Solo
processor.

deviceFamilyIsIntelCore2(190)

The processor family is Intel Core 2
processor.

deviceFamilyIsIntelCore2Duo
(191)

The processor family is Intel Core 2
Duo processor.

deviceFamilyIsIntelCore2Solo
(192)

The processor family is Intel Core2
Solo processor.

deviceFamilyIsIntelCore2Extrem The processor family is Intel Core2
e(193)
Extreme processor.
deviceFamilyIsIntelCore2Quad
(194)

The processor family is Intel Core2
Quad processor.

Device Group

333

Table 14-6. Processor Device Family (continued)
Variable Name: DellProcessorDeviceFamily
Data Type: Integer
Possible Data Values

Meaning of Data Value

deviceFamilyIsIntelCore2Extrem The processor family is Intel Core2
eMobile(195)
Extreme mobile processor.
deviceFamilyIsIntelCore2DuoMob The processor family is Intel Core2
ile(196)
Duo mobile processor.
deviceFamilyIsIntelCore2SoloMo The processor family is Intel Core2
bile(197)
Solo mobile processor.
deviceFamilyIsIntelCorei7(198) The processor family is Intel Core i7
processor.
deviceFamilyIsDualCoreIntelCel The processor family is Dual-Core Intel
eron(199)
Celeron Processor.
deviceFamilyIsIBM390(200)

The processor family is IBM390.

deviceFamilyIsG4(201)

The processor family is G4.

deviceFamilyIsG5(202)

The processor family is G5.

deviceFamilyIsESA390G6(203)

The processor family is ESA/390 G6.

deviceFamilyIszArchitectur
(204)

The processor family is z/Architectur
base.

deviceFamilyIsIntelCorei5(205) The processor family is Intel Core i5
processor.
deviceFamilyIsIntelCorei3(206) The processor family is Intel Core i3
processor.
deviceFamilyIsVIAC7-M(210)

The processor family is VIA C7-M.

deviceFamilyIsVIAC7-D(211)

The processor family is family is VIA
C7-D.

deviceFamilyIsVIAC7(212)

The processor family is VIA C7.

deviceFamilyIsVIAEden(213)

The processor family is VIA Eden.

deviceFamilyIsMultiCoreIntelXe The processor family is Multi-Core
on(214)
Intel Xeon processor.

334

Device Group

Table 14-6.

Processor Device Family (continued)

Variable Name: DellProcessorDeviceFamily
Data Type: Integer
Possible Data Values

Meaning of Data Value

deviceFamilyIsDualCoreIntelXeo The processor family is Dual-Core Intel
n3xxx(215)
Xeon processor 3xxx Series.
deviceFamilyIsQuadCoreIntelXeo The processor family is Quad-Core
n3xxx(216)
Intel Xeon processor 3xxx Series.
deviceFamilyIsVIANano(217)

The processor family is VIA Nano.

deviceFamilyIsDualCoreIntelXeo The processor family is Dual-Core Intel
n5xxx(218)
Xeon processor 5xxx Series.
deviceFamilyIsQuadCoreIntelXeo The processor family is Quad-Core
n5xxx(219)
Intel Xeon processor 5xxx Series.
deviceFamilyIsDualCoreIntelXeo The processor family is Dual-Core Intel
n7xxx(221)
Xeon processor 7xxx Series.
deviceFamilyIsQuadCoreIntelXeo The processor family is Quad-Core
n7xxx(222)
Intel Xeon processor 7xxx Series.
deviceFamilyIsMultiCoreIntelXe The processor family is Multi-Core
on7xxx(223)
Intel Xeon processor 7xxx Series.
deviceFamilyIsMultiCoreIntelXe The processor family is Multi-Core
on3400(224)
Intel Xeon processor 3400 Series.
deviceFamilyIsEmbeddedAMDOpert The processor family is Embedded
onQuadCore(230)
AMD Opteron Quad-Core.
deviceFamilyIsAMDPhenomTripleC The processor family is AMD Phenom
ore(231)
Triple-Core.
deviceFamilyIsAMDTurionUltraDu The processor family is AMD Turion
alCoreMobile(232)
Ultra Dual-Core mobile processor.
deviceFamilyIsAMDTurionDualCor The processor family is AMD Turion
eMobile(233)
Dual-Core mobile processor.
deviceFamilyIsAMDAthlonDualCor The processor family is AMD Athlon
e(234)
Dual-Core.
deviceFamilyIsAMDSempronSI
(235)

The processor family is AMD Sempron
SI.

Device Group

335

Table 14-6. Processor Device Family (continued)
Variable Name: DellProcessorDeviceFamily
Data Type: Integer
Possible Data Values

Meaning of Data Value

deviceFamilyIsAMDPhenomII(236) The processor family is AMD Phenom
II.
deviceFamilyIsAMDAthlonII(237) The processor family is AMD Athlon II.
deviceFamilyIsSixCoreAMDOptero The processor family is Six-Core AMD
n(238)
Opteron.
deviceFamilyIsAMDSempronM(239) The processor family is AMD Sempron
M.
deviceFamilyIsi860(250)

The processor family is i860.

deviceFamilyIsi960(251)

The processor family is i960.

deviceFamilyIsAMDOpteron6200
(61)

The processor family family is AMD
Opteron 6200 Series Processor.

deviceFamilyIsAMDOpteron4200
(61)

The processor family family is AMD
Opteron 4200 Series Processor.

Table 14-7. Cache Device Type
Variable Name: DellCacheDeviceType
Data Type: Integer
Possible Data Values

Meaning of Data Value

deviceTypeIsOther(1)

System cache type is not one of the
following:

deviceTypeIsUnknown(2)

System cache type is unknown.

deviceTypeIsInstruction(3)

System cache type is instruction.

deviceTypeIsData(4)

System cache type is data.

deviceTypeIsUnified(5)

System cache type is both instruction
and data.

336

Device Group

Table 14-8.

Cache Device Level

Variable Name: DellCacheDeviceLevel
Data Type: Integer
Possible Data Values

Meaning of Data Value

deviceLevelIsOther(1)

Device level is not one of the following:

deviceLevelIsUnknown(2)

Device level is unknown.

deviceLevelIsPrimary(3)

Device level is primary.

deviceLevelIsSecondary(4)

Device level is secondary.

deviceLevelIsTertiary(5)

Device level is tertiary.

Table 14-9.

Cache Device Write Policy

Variable Name: DellCacheDeviceWritePolicy
Data Type: Integer
Possible Data Values

Meaning of Data Value

deviceWritePolicyIsOther(1)

Device write policy is not
one of the following:

deviceWritePolicyIsUnknown(2)

Device write policy is
unknown.

deviceWritePolicyIsWriteBack(3)

Device write policy is
write back.

deviceWritePolicyIsWriteThrough(4)

Device write policy is
write through.

deviceWritePolicyIsVariesByAddress(5)

Device write policy varies
by address.

deviceWritePolicyIsDeterminedByIO(6)

Device write policy is
determined by I/O query.

Device Group

337

Table 14-10. Cache Device Status State
Variable Name: DellCacheDeviceStatusState
Data Type: Integer
Possible Data Values

Meaning of Data Value

other(1)

Device state is not one of the following:

unknown(2)

Device state is unknown.

enabled(3)

Device is enabled.

userDisabled(4)

Device is disabled by the user.

biosDisabled(5)

Device basic input/output system
(BIOS) is disabled.

Table 14-11. Cache Device ECC Type
Variable Name: DellPointingDeviceType
Data Type: Integer
Possible Data Values

Meaning of Data Value

deviceTypeIsOther(1)

Device type is not one of the following:

deviceTypeIsUnknown(2)

Device type is unknown.

deviceTypeIsAMouse(3)

Device type is a mouse.

deviceTypeIsATrackBall(4)

Device type is a track ball.

deviceTypeIsATrackPoint(5)

Device type is a track point.

deviceTypeIsAGlidePoint(6)

Device type is a glide point.

deviceTypeIsATouchPad(7)

Device type is a touch pad.

Table 14-12. Cache Device Associativity
Variable Name: DellCacheDeviceAssociativity
Data Type: Integer
Possible Data Values

Meaning of Data Value

deviceAssociativityIsOther(1)

Device associativity is not
one of the following:

338

Device Group

Table 14-12. Cache Device Associativity (continued)
Variable Name: DellCacheDeviceAssociativity
Data Type: Integer
Possible Data Values

Meaning of Data Value

deviceAssociativityIsUnknown(2)

Device associativity is
unknown.

deviceAssociativityIsDirectMapped(3) Device is direct mapped.
deviceAssociativityIsTwoWaySetAsso
ciative(4)

Device is two-way set
associative.

deviceAssociativityIsFourWaySetAsso Device is four-way set
ciative(5)
associative.
deviceAssociativityIsFullyAssociative Device is fully associative.
(6)
deviceAssociativityIsEightWaySetAsso Device is eight-way set
ciative(7)
associative.
deviceAssociativityIsSixteenWaySet
Associative(8)

Device is sixteen-way set
associative.

deviceAssociativityIs12WaySetAssoc
iative(9)

Device is 12-way
Set-Associative.

deviceAssociativityIs24WaySetAssoc
iative(10)

Device is 24-way
Set-Associative.

deviceAssociativityIs32WaySetAssoc
iative(11)

Device is 32-way
Set-Associative.

deviceAssociativityIs48WaySetAssoc
iative(12)

Device is 48-way
Set-Associative.

deviceAssociativityIs64WaySetAssoc
iative(13)

Device is 64-way
Set-Associative.

Device Group

339

Table 14-13. Cache Device Location
Variable Name: DellCacheDeviceLocation
Data Type: Integer
Possible Data Values

Meaning of Data Value

deviceLocationIsOther(1)

Device location is not one of the
following:

deviceLocationIsUnknown(2)

Device location is unknown.

deviceLocationIsInternal(3)

Device location is internal.

deviceLocationIsExternal(4)

Device location is external.

Table 14-14. Cache Device Static Random-Access Memory (SRAM) Type
Variable Name: DellCacheDeviceSRAMType
Data Type: Integer
Possible Data Values

Meaning of Data Value

deviceSRAMTypeIsOther(1)

Device SRAM type is not one of the
following:

deviceSRAMTypeIsUnknown(2)

Device SRAM type is unknown.

deviceSRAMTypeIsNonBurst(3)

Device SRAM type is nonburst.

deviceSRAMTypeIsBurst(4)

Device SRAM type is burst.

deviceSRAMTypeIsPipeBurst(5)

Device SRAM type is pipeburst.

deviceSRAMTypeIsSynchronous(6) Device SRAM type is synchronous.
deviceSRAMTypeIsAsynchronous(7) Device SRAM type is asynchronous.
Table 14-15. Memory Device Type Form Factor
Variable Name: DellMemoryDeviceFormFactor
Data Type: Integer
Possible Data Values

Meaning of Data Value

deviceFormFactorIsOther(1)

Device form factor is not one of
the following:

340

Device Group

Table 14-15. Memory Device Type Form Factor (continued)
Variable Name: DellMemoryDeviceFormFactor
Data Type: Integer
Possible Data Values

Meaning of Data Value

deviceFormFactorIsUnknown(2)

Device form factor is unknown.

deviceFormFactorIsSIMM(3)

Device form factor is SIMM.

deviceFormFactorIsSIP(4)

Device form factor is SIP.

deviceFormFactorIsAChip(5)

Device form factor is a chip.

deviceFormFactorIsDIP(6)

Device form factor is DIP.

deviceFormFactorIsZIP(7)

Device form factor is ZIP.

deviceFormFactorIsAProprietaryCard Device form factor is a proprietary
(8)
card.
deviceFormFactorIsDIMM(9)

Device form factor is DIMM.

deviceFormFactorIsTSOP(10)

Device form factor is TSOP.

deviceFormFactorIsARowOfChips(11)

Device form factor is a row of
chips.

deviceFormFactorIsRIMM(12)

Device form factor is RIMM.

deviceFormFactorIsSODIMM(13)

Device form factor is SODIMM.

deviceFormFactorIsSRIMM(14)

Device form factor is SRIMM.

deviceFormFactorIsFBDIMM(15)

Device form factor is FB-DIMM.

Table 14-16. Memory Device Type
Variable Name: DellMemoryDeviceType
Data Type: Integer
Possible Data Values

Meaning of Data Value

deviceTypeIsOther(1)

Device type is not one of the following:

deviceTypeIsUnknown(2)

Device type is unknown.

deviceTypeIsDRAM(3)

Device type is DRAM.

deviceTypeIsEDRAM(4)

Device type is EDRAM.

Device Group

341

Table 14-16. Memory Device Type (continued)
Variable Name: DellMemoryDeviceType
Data Type: Integer
Possible Data Values

Meaning of Data Value

deviceTypeIsVRAM(5)

Device type is VRAM.

deviceTypeIsSRAM(6)

Device type is SRAM.

deviceTypeIsRAM(7)

Device type is RAM.

deviceTypeIsROM(8)

Device type is ROM.

deviceTypeIsFLASH(9)

Device type is FLASH.

deviceTypeIsEEPROM(10)

Device type is EEPROM.

deviceTypeIsFEPROM(11)

Device type is FEPROM.

deviceTypeIsEPROM(12)

Device type is EPROM.

deviceTypeIsCDRAM(13)

Device type is CDRAM.

deviceTypeIs3DRAM(14)

Device type is 3DRAM.

deviceTypeIsSDRAM(15)

Device type is SDRAM.

deviceTypeIsSGRAM(16)

Device type is SGRAM.

deviceTypeIsRDRAM(17)

Device type is RDRAM.

deviceTypeIsDDR(18)

Device type is DDR.

deviceTypeIsDDR2(19)

Device type is DDR2.

deviceTypeIsDDR2FBDIMM(20)

Device type is DDR2 FB-DIMM.

deviceTypeIsDDR3(24)

Device type is DDR3.

deviceTypeIsFBD2(25)

Device type is FBD2.

342

Device Group

Table 14-17. Memory Device Type Details
Variable Name: DellMemoryDeviceTypeDetails
Data Type: Integer
Possible Data Values

Meaning of Data Value

deviceTypeDetailIsOther(2)

The detailed device type is not one of the
following:

deviceTypeDetailIsUnknown(4)

The detailed device type is unknown.

deviceTypeDetailIsFastPaged
(8)

The detailed device type is fast paged.

deviceTypeDetailIsStaticColum The detailed device type is static column.
n(16)
deviceTypeDetailIsPseudoStati The detailed device type is pseudo-static.
c(32)
deviceTypeDetailIsRAMBUS(64)

The detailed device type is RAMBUS.

deviceTypeDetailIsSynchronous The detailed device type is synchronous.
(128)
deviceTypeDetailIsCMOS(256)

The detailed device type is CMOS.

deviceTypeDetailIsEDO(512)

The detailed device type is EDO.

deviceTypeDetailIsWindowDRAM
(1024)

The detailed device type is Window
DRAM.

deviceTypeDetailIsCacheDRAM
(2048)

The detailed device type is Cache
DRAM.

deviceTypeDetailIsNonVolatile The detailed device type is Non-volatile.
(4096)
deviceTypeDetailIsRegistered
(8192)

The detailed device type is registered.

deviceTypeDetailIsNonRegister The detailed device type is noned(16384)
registered.

Device Group

343

Table 14-18. Generic Device Type
Variable Name: DellGenericDeviceType
Data Type: Integer
Possible Data Values

Meaning of Data Value

deviceTypeIsOther(1)

Device type is not one of the
following:

deviceTypeIsUnknown(2)

Device type is unknown.

deviceTypeIsAVideoDevice(3)

Device type is a video.

deviceTypeIsASCSIController(4)

Device type is a SCSI controller.

deviceTypeIsAnEthernetDevice(5)

Device type is Ethernet.

deviceTypeIsTokenRingDevice(6)

Device type is token ring.

deviceTypeIsASoundDevice(7)

Device type is sound.

Table 14-19. Memory Device Failure Modes
Variable Name: DellMemoryDeviceFailureModes
Data Type: Integer

NOTE: These values are bit masks, so combination values are possible.
Possible Data Values

Meaning of Data Value

(0)

Memory device has no
faults.

eccSingleBitCorrectionWarningRate(1)

Memory device has
exceeded the
Correctable Memory
Event warning rate.

eccSingleBitCorrectionFailureRate(2)

Memory device has
exceeded the
Correctable Memory
Event failure rate.

eccMultiBitFault(4)

Memory device has
encountered an
Uncorrectable Memory
Event.

344

Device Group

Table 14-19. Memory Device Failure Modes (continued)
Variable Name: DellMemoryDeviceFailureModes
Data Type: Integer

NOTE: These values are bit masks, so combination values are possible.
Possible Data Values

Meaning of Data Value

eccSingleBitCorrectionLoggingDisabled(8) Correctable Memory
Event logging for
memory device has been
disabled.
deviceDisabledBySpareActivation(16)

Memory device is
disabled because of spare
memory activation.

Table 14-20. Network Device Connection Status
Variable Name: DellNetworkDeviceConnectionStatus
Data Type: Integer
Possible Data Values

Meaning of Data Value

unknown(0)

Unable to determine connection status.

connected(1)

Media reports that device is connected.

disconnected(2)

Media reports that device is disconnected.

driverBad(3)

Driver cannot be opened to determine status.

driverDisabled(4)

Driver is disabled.

hardwareInitalizing(10)

Hardware is initializing.

hardwareResetting(11)

Hardware is resetting.

hardwareClosing(12)

Hardware is closing down.

hardwareNotReady(13)

Hardware is not ready.

Device Group

345

Table 14-21. Network Device Teaming Flags
Variable Name: DellNetworkDeviceTeamingFlags
Data Type: Integer

NOTE: These values are bit fields, so combination values are possible.
Possible Data Values

Meaning of Data Value

undefined(0)

Teaming flags are undefined.

noTeam(1)

Device is not part of any team.

teamingEnabled(2)

Teaming is enabled.

adapterFaultToleranceMode(4) Adapter fault tolerance teaming mode.
loadBalancingMode(8)

Load balancing teaming mode.

Table 14-22. Network Device TOE Capability Flags
Variable Name: DellNetworkDeviceTOECapabilityFlags
Data Type: Integer

NOTE: These values are bit fields, so combination values are possible.
Possible Data Values

Meaning of Data Value

none(0)

Querying for TOE capability is not supported.

unknown(1)

Querying for TOE capability is supported but
query returned an error.

available(2)

Device has TOE capability.

notAvailable(4)

Device does not have TOE capability.

cannotBeDetermined(8)

Querying for TOE capability is supported but
an error prevented querying.

driverNotResponding(16)

Querying for TOE capability is supported but
driver did not respond to query.

346

Device Group

Table 14-23. Network Device RDMA Capability Flags
Variable Name: DellNetworkDeviceRDMACapabilityFlags
Data Type: Integer

NOTE: These values are bit fields, so combination values are possible.
Possible Data Values

Meaning of Data Value

none(0)

Querying for RDMA capability is not
supported.

unknown(1)

Querying for RDMA capability is supported
but query returned an error.

available(2)

Device has RDMA capability.

notAvailable(4)

Device does not have RDMA capability.

cannotBeDetermined(8)

Querying for RDMA capability is supported
but an error prevented querying.

driverNotResponding(16)

Querying for RDMA capability is supported
but driver did not respond to query.

Table 14-24. Network Device iSCSI Capability Flags
Variable Name: DellNetworkDeviceiSCSICapabilityFlags
Data Type: Integer

NOTE: These values are bit fields, so combination values are possible.
Possible Data Values

Meaning of Data Value

none(0)

Querying for iSCSI capability is not supported.

unknown(1)

Querying for iSCSI capability is supported but
query returned an error.

available(2)

Device has iSCSI capability.

notAvailable(4)

Device does not have iSCSI capability.

cannotBeDetermined(8)

Querying for iSCSI capability is supported but
an error prevented querying.

driverNotResponding(16)

Querying for iSCSI capability is supported but
driver did not respond to query.

Device Group

347

Table 14-25. Managed System Services Device Type

Variable Name: DellManagedSystemServicesDeviceType
Data Type: Integer
Possible Data Values

Meaning of Data Value

baseDevice(0)

Device type is base device.

optionalDevice(1)

Device type is optional device.

Table 14-26. SD Card Device Type

Variable Name: DellSDCardDeviceType
Data Type: Integer
Possible Data Values

Meaning of Data Value

other(1)

Device type is other.

unknown(2)

Device type is unknown.

hypervisor(3)

Device type is Hypervisor.

vFlash(4)

Device type is Virtual Flash (vFlash.)

Table 14-27. SD Card Device Config Capabilities

Variable Name: DellSDCardDeviceConfigCapabilities
Data Type: Integer

NOTE: These values are bit fields, so combination values are possible.
Possible Data Values

Meaning of Data Value

none(0)

SD card device has none of the following
capabilities.

sdCapable(1)

SD media can be enabled.

vFlashCapable(2)

Virtual Flash (vFlash) can be enabled.

348

Device Group

Table 14-28. SD Card Device Config Settings

Variable Name: DellSDCardDeviceConfigSettings
Data Type: Integer

NOTE: These values are bit fields, so combination values are possible.
Possible Data Values

Meaning of Data Value

none(0)

SD card device has none of the following
settings.

sdEnabled(1)

SD media is enabled.

vFlashEnabled(2)

Virtual Flash (vFlash) is enabled.

Table 14-29. SD Card Device Card State

Variable Name: DellSDCardDeviceCardState
Data Type: Integer
Possible Data Values

Meaning of Data Value

none(0)

SD card state is none of the following states.

present(1)

Device is present.

ipmiReady(2)

Device is IPMI ready.

fullReady(4)

Device is full ready.

offline(8)

Device is offline.

failed(16)

Device is failed.

active(32)

Device is active.

bootable(64)

Device is bootable.

writeProtect(128)

Device is write-protected.

standby(256)

Device is in standby mode.

Table 14-30. SD Card Device Card Licensed

Variable Name: DellSDCardDeviceCardLicensed
Data Type: Integer
Possible Data Values

Meaning of Data Value

unlicensed(0)

SD card is not licensed by system vendor.

Device Group

349

Variable Name: DellSDCardDeviceCardLicensed
Data Type: Integer
Possible Data Values

Meaning of Data Value

licensed(1)

SD card is licensed by system vendor.

ipmiReady(2)

Device is IPMI ready.

fullReady(4)

Device is full ready.

offline(8)

Device is offline.

failed(16)

Device is failed.

active(32)

Device is active.

bootable(64)

Device is bootable.

writeProtect(128)

Device is write-protected.

standby(256)

Device is in standby mode.

350

Device Group

Slot Group

15

The Slot Group provides information about the types of slots that your
system supports. This management information base (MIB) group also
provides information about the voltages, capabilities, states, and settings that
are possible for these slots.

System Slot Group Table
The System Slot Group defines objects in the System Slot MIB table.

System Slot Table
The following object sets up the System Slot Table:
Name

systemSlotTable

Object ID

1.3.6.1.4.1.674.10892.1.1200.10

Description

Defines the System Slot Table.

Syntax

IntegerSystemStateTableEntry

Access

Not accessible

System Slot Table Entry
Name

systemSlotTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.1200.10.1

Description

Defines the System Slot Table entry.

Syntax

IntegerSystemSlotTableEntry

Access

Not accessible

Index

systemSlotchassisIndex, systemSlotIndex

Slot Group

351

System Slot Chassis Index
Name

systemSlotchassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.1200.10.1.1

Description

Defines the index (one-based) of this chassis.

Syntax

DellObjectRange

Access

Read-only

System Slot Index
Name

systemSlotIndex

Object ID

1.3.6.1.4.1.674.10892.1.1200.10.1.2

Description

Defines the index (one-based) of the system slot in this chassis.

Syntax

DellObjectRange

Access

Read-only

System Slot State Capabilities Unique
Name

systemSlotStateCapabilitiesUnique

Object ID

1.3.6.1.4.1.674.10892.1.1200.10.1.3

Description

Defines the capabilities of the system slot.

Syntax

DellSystemSlotStateCapabilities (See Table 15-1)

Access

Read-only

System Slot State Settings Unique
Name

systemSlotStateSettingsUnique

Object ID

1.3.6.1.4.1.674.10892.1.1200.10.1.4

Description

Defines the state of the system slot.

Syntax

DellSystemSlotStateSettings (See Table 15-2)

Access

Read-only

352

Slot Group

System Slot Status
Name

systemSlotStatus

Object ID

1.3.6.1.4.1.674.10892.1.1200.10.1.5

Description

Defines the status of the system slot.

Syntax

DellStatus

Access

Read-only

System Slot Current Usage
Name

systemSlotCurrentUsage

Object ID

1.3.6.1.4.1.674.10892.1.1200.10.1.6

Description

Defines the current usage of the system slot.

Syntax

DellStatus

Access

Read-only

System Slot Type
Name

systemSlotType

Object ID

1.3.6.1.4.1.674.10892.1.1200.10.1.7

Description

Defines the type of the system slot.

Syntax

DellSystemSlotType (See Table 15-3)

Access

Read-only

System Slot External Slot Name
Name

systemSlotSlotExternalSlotName

Object ID

1.3.6.1.4.1.674.10892.1.1200.10.1.8

Description

Defines the external connector name of the system slot.

Syntax

DellString

Access

Read-only

Slot Group

353

System Slot Length
Name

systemSlotLength

Object ID

1.3.6.1.4.1.674.10892.1.1200.10.1.9

Description

Defines the length of the system slot.

Syntax

DellSystemSlotLength (See Table 15-5)

Access

Read-only

System Slot Slot ID
Name

systemSlotSlotID

Object ID

1.3.6.1.4.1.674.10892.1.1200.10.1.10

Description

Defines the slot identification number of the system slot. A zero (0)
indicates that the slot is embedded on the motherboard.

Syntax

DellUnsigned32BitRange

Access

Read-only

System Slot Category
Name

systemSlotCategory

Object ID

1.3.6.1.4.1.674.10892.1.1200.10.1.11

Description

Defines the system slot category.

Syntax

DellUnsigned32BitRange

Access

Read-only

System Slot Hot-Plug Bus Width
Name

systemSlotHotPlugBusWidth

Object ID

1.3.6.1.4.1.674.10892.1.1200.10.1.12

Description

Defines the bus width of the hot-plug system slot.

Syntax

DellSystemSlotHotPlugBusWidth (See Table 15-7)

Access

Read-only

354

Slot Group

System Slot Hot-Plug Slot Speed
Name

systemSlotHotPlugSlotSpeed

Object ID

1.3.6.1.4.1.674.10892.1.1200.10.1.13

Description

Defines the slot speed in megahertz of the hot-plug system slot.
A zero (0) indicates that the slot speed is unknown.

Syntax

DellUnsigned32BitRange

Access

Read-only

System Slot Hot-Plug Adapter Speed
Name

systemSlotHotPlugAdapterSpeed

Object ID

1.3.6.1.4.1.674.10892.1.1200.10.1.14

Description

Defines the adapter speed in megahertz of the hot-plug system
slot. A zero (0) indicates that the slot speed is unknown.

Syntax

DellUnsigned32BitRange

Access

Read-only

System Slot Variable Values
This section includes definitions for server administrator-specific variable
values used in this section.
Table 15-1.

System Slot State Capabilities

Variable Name: DellSystemSlotStateCapabilities
Data Type: Integer
Possible Data Values

Meaning of Data Value

systemSlotHotPlugIsUnknown The system slot’s capabilities are unknown.
(1)
systemSlotHotPlugIsHotPlug The system slot supports hot-plug.
gableCapable(2)
systemSlotHotPlugCanBePower The system slot power (and corresponding
edOn(4)
light-emitting diode [LED]) can be
powered on.

Slot Group

355

Table 15-1. System Slot State Capabilities (continued)
Variable Name: DellSystemSlotStateCapabilities
Data Type: Integer
Possible Data Values

Meaning of Data Value

systemSlotHotPlugCanSignal The system slot attention state
Attention(8)
(and corresponding LED) can be set.
systemSlotHotPlugCanSignal Power on fault (and corresponding LED) can
PowerFault(16)
be detected due to a short or overcurrent.
systemSlotHotPlugCanSignal Adapter (card) present in slot (may not be
AdapterPresent(32)
powered) can be detected.
systemSlotHotPlugCanSignal The system slot power button can be pressed
PowerButtonPressed(64)
to signal a toggle of the power state.
canSupportAllHotPlugCapabi The system slot can support all
lities(126)
hot-plug capabilities.
systemSlotHotPlugIsUnknown The system slot’s capabilities are unknown.
(1)
systemSlotCanProvide5Volts The system slot can provide a
(128)
5-volt (V) supply.
systemSlotCanProvide3Point The system slot can provide a 3.3-V supply.
3Volts(256)
systemSlotCanSignalIfShared The system slot’s opening, if shared with
(512)
another slot, can be detected.
systemSlotCanSupportCard16 The system slot can support
(1024)
PC Card-16.
systemSlotCanSupportCardBus The system slot can support CardBus.
(2048)
systemSlotCanSupportZoomVid The system slot can support Zoom Video.
eo(4096)
systemSlotCanSupportModem The system slot can support modem
RingResume(8192)
ring resume.
systemSlotCanSupportPMESig The system slot can support Power
nal(16384)
Management Enable (PME#) signal.
canSupportAllSlotCapabilit The system slot can support all
ies(32640)
slot capabilities.

356

Slot Group

Table 15-2.

System Slot State Settings

Variable Name: DellSystemSlotStateSettings
Data Type: Integer
Possible Data Values

Meaning of Data Value

systemSlotHotPlugIsUnknown(1)

The system slot’s capabilities are
unknown.

systemSlotHotPlugIsHotPluggable(2) The system slot supports hot-plug.
systemSlotHotPlugIsPoweredOn(4)

The system slot power (and
corresponding LED) can be
powered on.

systemSlotHotPlugIsAtAttention(8)

The system slot attention state (and
corresponding LED) can be set.

systemSlotHotPlugIsHotPluggable(2) The system slot supports hot-plug.
systemSlotHotPlugIsPoweredOn(4)

The system slot power (and
corresponding LED) is on.

systemSlotHotPlugIsAtAttention(8)

The system slot attention state
(and corresponding LED) is on.

systemSlotHotPlugHasPowerFaulted
(16)

Power on fault (and corresponding
LED) was detected due to a short
or overcurrent.

systemSlotHotPlugAdapterIsPresent Adapter (card) present in slot
(32)
(may not be powered).
systemSlotHotPlugAdapterPresentAnd Adapter (card) present in slot
PoweredOn(36)
and powered.
systemSlotHotPlugPowerButtonPressed The system slot power button
(64)
pressed to signal a toggle of the
power state.
systemSlotProvides5Volts(128)

The system slot provides a 5-V
supply.

systemSlotProvides3Point3Volts(256) The system slot provides a 3.3-V
supply.
systemSlotIsShared(512)

The slot’s opening is shared with
another slot.

Slot Group

357

Table 15-2. System Slot State Settings (continued)
Variable Name: DellSystemSlotStateSettings
Data Type: Integer
Possible Data Values

Meaning of Data Value

systemSlotSupportsCard16(1024)

The system slot supports PC
Card-16.

systemSlotSupportsCardBus(2048)

The system slot supports
CardBus.

systemSlotSupportsZoomVideo(4096)

The system slot supports zoom
video.

systemSlotSupportsModemRingResume The system slot supports modem
(8192)
ring resume.
systemSlotSupportsPMESignal(16384) The system slot supports power
management enable (PME#)
signal.
supportsPMEand3P3Vand5VandHotPlugg The system slot supports power
able(16770)
management enable.
supportsPMEand3P3Vand5VhasAdapterO The system slot supports power
n(16804)
management event (PME),
supplies 3.3 V, and supplies 5 V.
The adapter is on.
supportsPMEand3P3Vand5VhasAdapter The system slot supports PME,
OnandisHotPluggable(16806)
supplies 3.3 V, and supplies 5 V.
The adapter is on and the system
slot is hot pluggable.
supportsPMEand3P3VIsSharedand5Vhas The system slot supports PME,
AdapterOnandisHotPluggable(17316) supplies 3.3 V, supplies 5 V, and
shares a slot opening. The adapter
is on and the system slot is
hot pluggable.

358

Slot Group

Table 15-3.

System Slot Type

Variable Name: DellSystemSlotType
Data Type: Integer
Possible Data Values

Meaning of Data Value

systemSlotIsOther(1)

The system slot type is not one of
following:

systemSlotIsUnknown(2)

The system slot type is unknown.

systemSlotIsISA(3)

The system slot is Industry
Standard Architecture (ISA).

systemSlotIsMCA(4)

The system slot is Micro Channel
Architecture (MCA).

systemSlotIsEISA(5)

The system slot is Extended Industry
Standard Architecture (EISA).

systemSlotIsPCI(6)

The system slot is Peripheral
Component Interconnect (PCI).

systemSlotIsPCMCIA(7)

The system slot is compliant with
the Personal Computer Memory
Card International Association
(PCMCIA) standards.

systemSlotIsVLVESA(8)

The system slot is Very Low Voltage
Enterprise System Architecture
(VLVESA).

systemSlotIsProprietary(9)

The system slot is proprietary.

systemSlotIsProcessorCard(10)

The system slot is a processor card.

systemSlotIsProprietaryMemory(11)

The system slot is proprietary memory.

systemSlotIsIORiserCard(12)

The system slot is an I/O riser card.

systemSlotIsNuBUS(13)

The system slot is a NuBus.

systemSlotIsPCI66MHz(14)

The system slot is a PCI66MHz.

systemSlotIsAGP(15)

The system slot is an Advanced
Graphics Port (AGP).

systemSlotIsAGP2X(16)

The system slot is an AGP 2x card.

systemSlotIsAGP4X(17)

The system slot is an AGP 4x card.
Slot Group

359

Table 15-3. System Slot Type (continued)
Variable Name: DellSystemSlotType
Data Type: Integer
Possible Data Values

Meaning of Data Value

systemSlotIsPC98C20(18)

The system slot is a PC-98/C20.

systemSlotIsPC98C24(19)

The system slot is a PC-98/C24.

systemSlotIsPC98E(20)

The system slot type is PC-98/E.

systemSlotIsPC98LocalBus(21)

The system slot type is a PC-98
local bus.

systemSlotIsPC98Card(22)

The system slot type is a PC-98 card.

systemSlotIsPCIX(23)

The system slot type is a PCIX card.

systemSlotIsPCIExpress(24)

The system slot type is a PCI
Express card.

systemSlotIsAGP8X(25)

The system slot type is an AGP 8x
card.

systemSlotIsPCIExpressX1(166)

The system slot type is a PCI
Express x1.

systemSlotIsPCIExpressX2(167)

The system slot type is a PCI
Express x2.

systemSlotIsPCIExpressX4(168)

The system slot type is a PCI
Express x4.

systemSlotIsPCIExpressX8(169)

The system slot type is a PCI
Express x8.

systemSlotIsPCIExpressX16(170)

The system slot type is a PCI
Express x16.

systemSlotIsPCIExpressGen2(171)

The system slot type is PCI Express
Gen 2.

systemSlotIsPCIExpressGen2X1(172)

The system slot type is PCI Express
Gen 2 x1.

systemSlotIsPCIExpressGen2X2(173) The system slot type is PCI Express
Gen 2 x2.

360

Slot Group

Table 15-3.

System Slot Type (continued)

Variable Name: DellSystemSlotType
Data Type: Integer
Possible Data Values

Meaning of Data Value

systemSlotIsPCIExpressGen2X4(174)

The system slot type is PCI Express
Gen 2 x4.

systemSlotIsPCIExpressGen2X8(175)

The system slot type is PCI Express
Gen 2 x8.

systemSlotIsPCIExpressGen2X16(176) The system slot type is PCI Express
Gen 2 x16.
Table 15-4.

System Slot Usage

Variable Name: DellSystemSlotUsage
Data Type: Integer
Possible Data Values

Meaning of Data Value

systemSlotUsageIsOther(1)

The system slot usage is not one of
following:

systemSlotUsageIsUnknown(2)

The system slot usage is unknown.

systemSlotUsageIsAvailable(3) The system slot is available.
systemSlotUsageIsInUse(4)
Table 15-5.

The system slot is in use.

System Slot Length

Variable Name: DellSystemSlotLength
Data Type: Integer
Possible Data Values

Meaning of Data Value

systemSlotLengthIsOther(1)

The system slot length is not one of
following:

systemSlotLengthIsUnknown(2) The system slot length is unknown.
systemSlotLengthIsShort(3)

The system slot length is short.

systemSlotLengthIsLong(4)

The system slot length is long.

Slot Group

361

Table 15-6. System Slot Category
Variable Name: DellSystemSlotCategory
Data Type: Integer
Possible Data Values

Meaning of Data Value

systemSlotCategoryIsOther(1)

The system slot category is not
one of following:

systemSlotCategoryIsUnknown(2)

The system slot category is
unknown.

systemSlotCategoryIsBusConnector(3) The system slot is a bus
connector.
systemSlotCategoryIsPCMCIA(4)

The system slot category is
PCMCIA.

systemSlotCategoryIsMotherboard(5)

The system slot is a
motherboard.

Table 15-7. Hot-Plug Bus Width
Variable Name: DellSystemSlotHotPlugBusWidth
Data Type: Integer
Possible Data Values

Meaning of Data Value

busWidthIsOther(1)

The system slot bus width is not one of following:

busWidthIsUnknown(2)

The system slot bus width is unknown.

busWidthIs8bits(3)

The system slot bus width is 8 bits.

busWidthIs16bits(4)

The system slot bus width is 16 bits.

busWidthIs32bits(5)

The system slot bus width is 32 bits.

busWidthIs64bits(6)

The system slot bus width is 64 bits.

busWidthIs128bits(7)

The system slot bus width is 128 bits.

busWidthIs1xOrx1(8)

The system slot bus width is 1x or x1.

busWidthIs2xOrx2(9)

The system slot bus width is 2x or x2.

busWidthIs4xOrx4(10)

The system slot bus width is 4x or x4.

busWidthIs8xOrx8(11)

The system slot bus width is 8x or x8.

362

Slot Group

Table 15-7.

Hot-Plug Bus Width (continued)

Variable Name: DellSystemSlotHotPlugBusWidth
Data Type: Integer
Possible Data Values

Meaning of Data Value

busWidthIs12xOrx12(12)

The system slot bus width is 12x or x12.

busWidthIs16xOrx16(13)

The system slot bus width is 16x or x16.

busWidthIs32xOrx32(14)

The system slot bus width is 32x or x32.

NOTE: System slot bus width of type n bits are for parallel buses such as PCI.
NOTE: System slot bus width of type nx or xn are for serial buses such as
PCI Express.

Slot Group

363

364

Slot Group

16
16

Memory Group

The Memory Group provides information about the physical memory in your
system. Variables in this group include error correction type, location, and
different types of memory use, such as cache, flash, system, video, and
nonvolatile memory.

Physical Memory Tables
The following management information base (MIB) tables define the objects
in the Memory Group:
•

"Physical Memory Array Table" on page 365

•

"Physical Memory Array Mapped Table" on page 371

•

"Physical Memory Configuration Table" on page 374

•

"Physical Memory Logging Table" on page 377

•

"Redundant Memory Unit Table" on page 379

•

"Physical Memory Card Table" on page 382

Physical Memory Array Table
The physical memory array is the entire physical memory of a system.
The example that follows shows variable values for a system that has one
128-megabyte (MB) dual in-line memory module (DIMM):
•

physicalMemoryArrayMaximumSize = 2,097,152 kilobytes (KB) or
2 gigabytes (GB)

•

physicalMemoryArrayTotalNumberSockets = 4 (the example system has
four DIMM slots on the motherboard)

Memory Group

365

•

366

physicalMemoryArrayInUseNumberSockets = 1 (there is only one DIMM
installed)

Memory Group

The following object sets up the Physical Memory Array Table:
Name

physicalMemoryArrayTable

Object ID

1.3.6.1.4.1.674.10892.1.1300.10

Description

Defines the Physical Memory Array Table.

Syntax

PhysicalMemoryArrayTableEntry

Access

Not accessible

Physical Memory Array Table Entry
Name

physicalMemoryArrayTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.1300.10.1

Description

Defines the Physical Memory Array Table entry.

Syntax

PhysicalMemoryArrayTableEntry

Access

Not accessible

Index

physicalMemoryArraychassisIndex, physicalMemoryArrayIndex

Physical Memory Array Chassis Index
Name

physicalMemoryArraychassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.1300.10.1.1

Description

Defines the index (one-based) of this chassis.

Syntax

DellObjectRange

Access

Read-only

Physical Memory Array Index
Name

physicalMemoryArrayIndex

Object ID

1.3.6.1.4.1.674.10892.1.1300.10.1.2

Description

Defines the index (one-based) of the physical memory array in
this chassis.

Syntax

DellObjectRange

Access

Read-only
Memory Group

367

Physical Memory Array State Capabilities
Name

physicalMemoryArrayStateCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.1300.10.1.3

Description

Defines the capabilities of the physical memory array.

Syntax

DellStateCapabilities

Access

Read-only

Physical Memory Array State Settings
Name

physicalMemoryArrayStateSettings

Object ID

1.3.6.1.4.1.674.10892.1.1300.10.1.4

Description

Defines the state of the physical memory array.

Syntax

DellStateSettings

Access

read-write

Physical Memory Array Status
Name

physicalMemoryArrayStatus

Object ID

1.3.6.1.4.1.674.10892.1.1300.10.1.5

Description

Defines the status of the physical memory array.

Syntax

DellStatus

Access

Read-only

Physical Memory Array Use
Name

physicalMemoryArrayUse

Object ID

1.3.6.1.4.1.674.10892.1.1300.10.1.6

Description

Defines the use of the physical memory array.

Syntax

DellPhysicalMemoryArrayUse (See Table 16-2)

Access

Read-only

368

Memory Group

Physical Memory Array Error Checking and Correcting (ECC) Type
Name

physicalMemoryArrayECCType

Object ID

1.3.6.1.4.1.674.10892.1.1300.10.1.7

Description

Defines the ECC type used by the physical memory array.

Syntax

DellPhysicalMemoryArrayECCType (See Table 16-2)

Access

Read-only

Physical Memory Array Location
Name

physicalMemoryArrayLocation

Object ID

1.3.6.1.4.1.674.10892.1.1300.10.1.8

Description

Defines the location of the physical memory array.

Syntax

DellPhysicalMemoryArrayLocation (See Table 16-1)

Access

Read-only

Physical Memory Array Maximum Size
Name

physicalMemoryArrayMaximumSize

Object ID

1.3.6.1.4.1.674.10892.1.1300.10.1.9

Description

Defines the size in KB of the physical memory array.

Syntax

DellUnsigned32BitRange

Access

Read-only

Physical Memory Array Total Number Sockets
Name

physicalMemoryArrayTotalNumberSockets

Object ID

1.3.6.1.4.1.674.10892.1.1300.10.1.10

Description

Defines the total number of memory sockets available for the
physical memory array.

Syntax

DellUnsigned32BitRange

Access

Read-only

Memory Group

369

Physical Memory Array In Use Number Sockets
Name

physicalMemoryArrayInUseNumberSockets

Object ID

1.3.6.1.4.1.674.10892.1.1300.10.1.11

Description

Defines the total number of memory sockets in use by the
physical memory array.

Syntax

DellUnsigned32BitRange

Access

Read-only

Physical Memory Array ECC Error Nonrecoverable Threshold
Name

physicalMemoryArrayECCErrorNonRecoverbeThreshold

Object ID

1.3.6.1.4.1.674.10892.1.1300.10.1.12

Description

Defines the value of the physical memory array Error Checking and
Correction (ECC) error nonrecoverable threshold.

Syntax

DellSigned32BitRange

Access

Read-only

Physical Memory Array ECC Error Critical Threshold
Name

physicalMemoryArrayECCErrorCriticalThreshold

Object ID

1.3.6.1.4.1.674.10892.1.1300.10.1.13

Description

Defines the value of the physical memory array ECC error critical
threshold.

Syntax

DellSigned32BitRange

Access

Read-only

Physical Memory Array ECC Error Noncritical Threshold
Name

physicalMemoryArrayECCErrorNonCriticalThreshold

Object ID

1.3.6.1.4.1.674.10892.1.1300.10.1.14

Description

Defines the value of the physical memory array ECC error
noncritical threshold.

Syntax

DellSigned32BitRange

Access

read-write

370

Memory Group

Physical Memory Array Redundant Memory Unit Index Reference
Name

physicalMemoryArrayRedundantMemoryUnitIndex
Reference

Object ID

1.3.6.1.4.1.674.10892.1.1300.10.1.15

Description

Defines the index to the associated Redundant Memory Unit in
this chassis.

Syntax

DellObjectRange

Access

Read-only

Physical Memory Array Mapped Table
The physical memory array is divided into memory array mapped addresses.
The following object sets up the Physical Memory Array Mapped Table:
Name

physicalMemoryArrayMappedTable

Object ID

1.3.6.1.4.1.674.10892.1.1300.20

Description

Defines the Physical Memory Array Mapped Table.

Syntax

PhysicalMemoryArrayMappedTableEntry

Access

Not accessible

Physical Memory Array Mapped Table Entry
Name

PhysicalMemoryArrayMappedTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.1300.20.1

Description

Defines the Physical Memory Array Mapped Table entry.

Syntax

PhysicalMemoryArrayMappedTableEntry

Access

Not accessible

Index

physicalMemoryArrayMappedchassisIndex,
physicalMemoryArrayMappedIndex

Memory Group

371

Physical Memory Array Mapped Chassis Index
Name

physicalMemoryArrayMappedchassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.1300.20.1.1

Description

Defines the index (one-based) of this chassis.

Syntax

DellObjectRange

Access

Read-only

Physical Memory Array Mapped Index
Name

physicalMemoryArrayMappedIndex

Object ID

1.3.6.1.4.1.674.10892.1.1300.20.1.2

Description

Defines the index (one-based) of the memory array mapped
address in this chassis.

Syntax

DellObjectRange

Access

Read-only

Physical Memory Array Mapped State Capabilities
Name

physicalMemoryArrayMappedStateCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.1300.20.1.3

Description

Defines the capabilities of the memory array mapped address.

Syntax

DellStateCapabilities

Access

Read-only

Physical Memory Array Mapped State Settings
Name

physicalMemoryArrayMappedStateSettings

Object ID

1.3.6.1.4.1.674.10892.1.1300.20.1.4

Description

Defines the state of the memory array mapped address.

Syntax

DellStateSettings

Access

Read-write

372

Memory Group

Physical Memory Array Mapped Status
Name

physicalMemoryArrayMappedStatus

Object ID

1.3.6.1.4.1.674.10892.1.1300.20.1.5

Description

Defines the status of the memory array mapped address.

Syntax

DellStatus

Access

Read-only

Physical Memory Array Index Reference
Name

physicalMemoryArrayIndexReference

Object ID

1.3.6.1.4.1.674.10892.1.1300.20.1.6

Description

Defines the index to the associated physical memory array in this
chassis.

Syntax

DellObjectRange

Access

Read-only

Physical Memory Array Mapped Starting Address
Name

physicalMemoryArrayMappedStartingAddress

Object ID

1.3.6.1.4.1.674.10892.1.1300.20.1.7

Description

Defines the physical starting address in KB of the memory array
mapped address.

Syntax

DellUnsigned64BitRange

Access

Read-only

Physical Memory Array Mapped Ending Address
Name

physicalMemoryArrayMappedEndingAddress

Object ID

1.3.6.1.4.1.674.10892.1.1300.20.1.8

Description

Defines the physical ending address in KB of the memory array
mapped address.

Syntax

DellUnsigned64BitRange

Access

Read-only
Memory Group

373

Physical Memory Array Mapped Partition Width
Name

physicalMemoryArrayMappedPartitionWidth

Object ID

1.3.6.1.4.1.674.10892.1.1300.20.1.9

Description

Defines the number of memory devices that form a single row in
the memory array mapped address. A zero (0) indicates that the
number is unknown.

Syntax

DellUnsigned32BitRange

Access

Read-only

Physical Memory Configuration Table
This table defines how the physical memory of a system chassis is set up, for
example, which redundant memory types are supported and whether
redundant memory is active.
The following object sets up the Physical Memory Configuration Table:
Name

physicalMemoryConfigTable

Object ID

1.3.6.1.4.1.674.10892.1.1300.30

Description

Defines the Physical Memory Configuration Table.

Syntax

SEQUENCE OF PhysicalMemoryConfigTableEntry

Access

Not accessible

Physical Memory Configuration Table Entry
Name

physicalMemoryConfigTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.1300.30.1

Description

Defines the Physical Memory Configuration Table entry.

Syntax

PhysicalMemoryConfigTableEntry

Access

Not accessible

Index

physicalMemoryConfigChassisIndex,
physicalMemoryConfigIndex

374

Memory Group

Physical Memory Configuration Chassis Index
Name

physicalMemoryConfigChassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.1300.30.1.1

Description

Defines the index (one-based) of the chassis associated with the
physical memory configuration.

Syntax

DellObjectRange

Access

Read-only

Physical Memory Configuration Index
Name

physicalMemoryConfigIndex

Object ID

1.3.6.1.4.1.674.10892.1.1300.30.1.2

Description

Defines the index (one-based) of the physical memory
configuration.

Syntax

DellObjectRange

Access

Read-only

Physical Memory Configuration State Capabilities
Name

physicalMemoryConfigStateCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.1300.30.1.3

Description

Defines the state capabilities of the physical memory configuration.

Syntax

DellPhysicalMemoryConfigStateCapabilities

Access

Read-only

Physical Memory Configuration State Settings
Name

physicalMemoryConfigStateSettings

Object ID

1.3.6.1.4.1.674.10892.1.1300.30.1.4

Description

Defines the state settings of the physical memory configuration.

Syntax

DellPhysicalMemoryConfigStateSettings

Access

Read-write

Memory Group

375

Physical Memory Configuration Status
Name

physicalMemoryConfigStatus

Object ID

1.3.6.1.4.1.674.10892.1.1300.30.1.5

Description

Defines the status of the physical memory configuration.

Syntax

DellStatus

Access

Read-only

Physical Memory Configuration Redundant Capabilities
Name

physicalMemoryConfigRedundantCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.1300.30.1.6

Description

Defines the redundant capabilities of the physical memory.

Syntax

DellPhysicalMemoryConfigRedundantCapabilities

Access

Read-only

Physical Memory Configuration Redundant Settings
Name

physicalMemoryConfigRedundantSettings

Object ID

1.3.6.1.4.1.674.10892.1.1300.30.1.7

Description

Defines the redundant settings of the physical memory.

Syntax

DellPhysicalMemoryConfigRedundantSettings

Access

Read-write

Physical Memory Configuration MOM Capabilities
Name

physicalMemoryConfigMOMCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.1300.30.1.8

Description

Defines the Memory Operating Mode capabilities of the
physical memory.

Syntax

DellPhysicalMemoryConfigMOMCapabilities

Access

Read-only

376

Memory Group

Physical Memory Configuration MOM Settings
Name

physicalMemoryConfigMOMSettings

Object ID

1.3.6.1.4.1.674.10892.1.1300.30.1.9

Description

Defines the Memory Operating Mode settings of the physical
memory.

Syntax

DellPhysicalMemoryConfigMOMSettings

Access

Read-only

Physical Memory Logging Table
This table defines the conditions for logging system memory events.
The following object sets up the Physical Memory Logging Table:
Name

physicalMemoryLoggingTable

Object ID

1.3.6.1.4.1.674.10892.1.1300.40

Description

Defines the Physical Memory Logging Table.

Syntax

SEQUENCE OF PhysicalMemoryLoggingTableEntry

Access

Not accessible

Physical Memory Logging Table Entry
Name

physicalMemoryLoggingTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.1300.40.1

Description

Defines the Physical Memory Logging Table entry.

Syntax

PhysicalMemoryLoggingTableEntry

Access

Not accessible

Index

physicalMemoryLoggingChassisIndex,
physicalMemoryLoggingIndex

Memory Group

377

Physical Memory Logging Chassis Index
Name

physicalMemoryLoggingChassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.1300.40.1.1

Description

Defines the index (one-based) of the chassis associated with the
physical memory logging.

Syntax

DellObjectRange

Access

Read-only

Physical Memory Logging Index
Name

physicalMemoryLoggingIndex

Object ID

1.3.6.1.4.1.674.10892.1.1300.40.1.2

Description

Defines the index (one-based) of the physical memory logging.

Syntax

DellObjectRange

Access

Read-only

Physical Memory Logging Capabilities
Name

physicalMemoryLoggingCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.1300.40.1.3

Description

Defines the capabilities of the physical memory logging.

Syntax

DellPhysicalMemoryLoggingCapabilities

Access

Read-only

Physical Memory Logging Settings
Name

physicalMemoryLoggingSettings

Object ID

1.3.6.1.4.1.674.10892.1.1300.40.1.4

Description

Defines the settings of the physical memory logging.

Syntax

DellPhysicalMemoryLoggingSettings

Access

Read-write

378

Memory Group

Physical Memory Logging Status
Name

physicalMemoryLoggingStatus

Object ID

1.3.6.1.4.1.674.10892.1.1300.40.1.5

Description

Defines the status of the physical memory logging.

Syntax

DellStatus

Access

Read-only

Redundant Memory Unit Table
This table reports the status of redundant memory within a particular system
chassis.
The following object sets up the Redundant Memory Unit Table:
Name

redundantMemoryUnitTable

Object ID

1.3.6.1.4.1.674.10892.1.1300.50

Description

Defines the Redundant Memory Unit Table.

Syntax

SEQUENCE OF RedundantMemoryUnitTableEntry

Access

Not accessible

Memory Group

379

Redundant Memory Unit Table Entry
Name

redundantMemoryUnitTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.1300.50.1

Description

Defines the Redundant Memory Unit Table entry.

Syntax

RedundantMemoryUnitTableEntry

Access

Not accessible

Index

redundantMemoryUnitChassisIndex,
redundantMemoryUnitIndex

Redundant Memory Unit Chassis Index
Name

redundantMemoryUnitChassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.1300.50.1.1

Description

Defines the index (one-based) of the chassis associated with the
redundant memory unit.

Syntax

DellObjectRange

Access

Read-only

Redundant Memory Unit Index
Name

redundantMemoryUnitIndex

Object ID

1.3.6.1.4.1.674.10892.1.1300.50.1.2

Description

Defines the index (one-based) of the redundant memory unit.

Syntax

DellObjectRange

Access

Read-only

Redundant Memory Unit State Capabilities
Name

redundantMemoryUnitStateCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.1300.50.1.3

Description

Defines the state capabilities of the redundant memory unit.

Syntax

DellStateCapabilities

Access

Read-only

380

Memory Group

Redundant Memory Unit State Settings
Name

redundantMemoryUnitStatesettings

Object ID

1.3.6.1.4.1.674.10892.1.1300.50.1.4

Description

Defines the state settings of the redundant memory unit.

Syntax

DellStateSettings

Access

Read-write

Redundant Memory Unit Redundancy Status
Name

redundantMemoryUnitRedundancyStatus

Object ID

1.3.6.1.4.1.674.10892.1.1300.50.1.5

Description

Defines the redundancy status of the redundant memory unit.

Syntax

DellStatusRedundancy

Access

Read-only

Redundant Memory Unit Name
Name

redundantMemoryUnitName

Object ID

1.3.6.1.4.1.674.10892.1.1300.50.1.6

Description

Defines the name of the redundant memory unit.

Syntax

DellString

Access

Read-only

Redundant Memory Unit Status
Name

redundantMemoryUnitStatus

Object ID

1.3.6.1.4.1.674.10892.1.1300.50.1.7

Description

Defines the status of the redundant memory unit.

Syntax

DellStatus

Access

Read-only

Memory Group

381

Physical Memory Card Table
This table defines the name of the memory card, the total number of device
slots present on the memory card, and the number of memory device slots in
use on the memory card.
The following objects set up the Physical Memory Card Table:
Physical Memory Card Table
Name

physicalMemoryCardTable

Object ID

1.3.6.1.4.1.674.10892.1.1300.60

Description

Defines the Physical Memory Card Table.

Syntax

SEQUENCE OF PhysicalMemoryCardTableEntry

Access

Not accessible

Physical Memory Card Table Entry
Name

physicalMemoryCardTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.1300.60.1

Description

Defines the Physical Memory Card Table Entry.

Syntax

PhysicalMemoryCardTableEntry

Access

Not accessible

Index

physicalMemoryCardChassisIndex, physicalMemoryCardIndex

Physical Memory Card Chassis Index
Name

physicalMemoryCardChassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.1300.60.1.1

Description

Defines the index (one-based) of the associated chassis.

Syntax

DellObjectRange

Access

Read-only

382

Memory Group

Physical Memory Card Index
Name

physicalMemoryCardIndex

Object ID

1.3.6.1.4.1.674.10892.1.1300.60.1.2

Description

Defines the index (one-based) of the Physical Memory Card.

Syntax

DellObjectRange

Access

Read-only

Physical Memory Card State Capabilities
Name

physicalMemoryCardStateCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.1300.60.1.3

Description

Defines the state capabilities of the Physical Memory Card.

Syntax

DellStateCapabilities

Access

Read-only

Physical Memory Card State Settings
Name

physicalMemoryCardStateSettings

Object ID

1.3.6.1.4.1.674.10892.1.1300.60.1.4

Description

Defines the state settings of the Physical Memory Card.

Syntax

DellStateSettings

Access

Read-write

Physical Memory Card Status
Name

physicalMemoryCardStatus

Object ID

1.3.6.1.4.1.674.10892.1.1300.60.1.5

Description

Defines the status of the Physical Memory Card.

Syntax

DellStatus

Access

Read-only

Memory Group

383

Physical Memory Card Name
Name

physicalMemoryCardName

Object ID

1.3.6.1.4.1.674.10892.1.1300.60.1.6

Description

Defines the name of the Physical Memory Card.

Syntax

DellString

Access

Read-only

Physical Memory Card Total Number Sockets
Name

physicalMemoryCardTotalNumberSockets

Object ID

1.3.6.1.4.1.674.10892.1.1300.60.1.7

Description

Defines the total number of memory sockets available on the
Physical Memory Card. 2,147,483,647 indicates an unknown
number of sockets.

Syntax

DellUnsigned32BitRange

Access

Read-only

Physical Memory Card In Use Number Sockets
Name

physicalMemoryCardInUseNumberSockets

Object ID

1.3.6.1.4.1.674.10892.1.1300.60.1.8

Description

Defines the number of memory sockets in use on the Physical
Memory Card. Zero indicates that the Physical Memory Card is
not installed or has a configuration error.

Syntax

DellUnsigned32BitRange

Access

Read-only

384

Memory Group

Physical Memory Card Physical Memory Array Index Reference
Name

physicalMemoryCardPhyMemArrayIndexReference

Object ID

1.3.6.1.4.1.674.10892.1.1300.60.1.9

Description

Defines the index (one-based) of the Physical Memory Array
Table entry for the physical memory array with the same chassis
index that this physical memory card is associated with.

Syntax

DellObjectRange

Access

Read-only

Memory Group Variable Values
This section includes definitions for server administrator-specific variable
values used in this section.
Table 16-1.

Physical Memory Array Location

Variable Name: DellPhysicalMemoryArrayLocation
Data Type: Integer
Possible Data Values

Meaning of Data Value

memoryArrayLocationIsOther(1)

The memory array
location is not one of the
following:

memoryArrayUseIsUnknown(2)

The memory array use is
unknown.

memoryArrayUseIsSystemMemory(3)

The memory array is
system memory.

memoryArrayUseIsVideoMemory(4)

The memory array is video
memory.

memoryArrayUseIsFLASHMemory(5)

The memory array is
FLASH memory.

memoryArrayUseIsNonVolatileRAMMemory(6) The memory array is
nonvolatile RAM.
memoryArrayUseIsCacheMemory(7)

The memory array is cache
memory.

Memory Group

385

Table 16-1. Physical Memory Array Location (continued)
Variable Name: DellPhysicalMemoryArrayLocation
Data Type: Integer
Possible Data Values

Meaning of Data Value

memoryArrayLocationIsPCMCIA(8)

The memory array
location is a Personal
Computer Memory Card
International Association
(PCMCIA) option card.

memoryArrayLocationIsProprietary(9)

The memory array
location is a proprietary
option card.

memoryArrayLocationIsNUBUS(10)

The memory array
location is a NuBus bus.

memoryArrayLocationIsPC98C20(11)

The memory array
location is a PC-98/C20
option card.

memoryArrayLocationIsPC98C24(12)

The memory array
location is a PC-98/C24
option card.

memoryArrayLocationIsPC98E(13)

The memory array
location is a PC-98/E
option card.

memoryArrayLocationIsPC98LocalBus(14)

The memory array
location is a PC-98/Local
bus option card.

memoryArrayLocationIsPC98Card(15)

The memory array
location is a PC-98/Card
slot option card.

386

Memory Group

Table 16-2.

Physical Memory Array ECC Type Definitions

Variable Name: DellPhysicalMemoryArrayECCType
Data Type: Integer
Possible Data Values

Meaning of Data Value

memoryArrayECCTypeIsOther(1)

There is not one of the following:

memoryArrayECCTypeIsUnknown(2)

The memory array ECC type is
unknown.

memoryArrayECCTypeIsNone(3)

The memory array ECC type is
none.

memoryArrayECCTypeIsParity(4)

The memory array ECC type is
parity.

memoryArrayECCTypeIsSingleBitECC(5) The memory array ECC type is
Correctable Memory Event ECC.
memoryArrayECCTypeIsMultiBitECC(6)

The memory array ECC type is
Uncorrectable Memory Event
ECC.

memoryArrayECCTypeIsCRC(7)

The memory array ECC type is
CRC.

Table 16-3.

Physical Memory Configuration State Capabilities

Variable Name: DellPhysicalMemoryConfigStateCapabilities
Data Type: Integer
Possible Data Values

Meaning of Data Value

If set to 0 (zero)

There are no state capabilities.

unknownCapabilities(1)

State capabilities are unknown.

enableCapable(2)

Object enable/disable is supported.

notReadyCapable(4)

Object not ready is supported.

Memory Group

387

Table 16-4. Physical Memory Configuration State Settings
Variable Name: DellPhysicalMemoryConfigStateSettings
Data Type: Integer
Possible Data Values

Meaning of Data Value

If set to 0 (zero)

There are no state settings.

unknown(1)

State settings are unknown.

enabled(2)

Object is disabled (offline) 0,
or enabled (online) 1.

notReady(4)

Object not ready.

redundantMemoryIsActive(8)

Redundant memory is active
(in use)

enabledAndRedundantMemoryIsActive(10) Redundant memory is
enabled and in use.
Table 16-5. Physical Memory Configuration Redundant Capabilities
Variable Name:

DellPhysicalMemoryConfigRedundantCapabilities
Data Type: Integer
Possible Data Values

Meaning of Data Value

If set to 0 (zero)

There are no redundant memory capabilities.

unknownCapabilities(1)

Redundant capabilities are unknown.

The redundant capabilities are:
spareCapable(2)

Spare redundant memory feature is supported.

mirrorCapable(4)

Mirror redundant memory feature is supported.

spareAndMirrorCapable(6) Spare and mirror redundant memory features are
supported.
raidCapable(8)

Redundant Array of Independent disks (RAID)
redundant memory feature is supported.

dddcCapable(16)

DDDC redundancy is supported.

388

Memory Group

Table 16-6.

Physical Memory Configuration Redundant Settings

Variable Name:

DellPhysicalMemoryConfigRedundantSettings
Data Type: Integer
Possible Data Values

Meaning of Data Value

If set to 0 (zero)

There are no redundant memory settings enabled.

unknown(1)

Redundant settings are unknown.

The following redundant settings are mutually exclusive:
spareEnabled(2)

Spare redundant memory feature is enabled.

mirrorEnabled(4)

Mirror redundant memory feature is enabled.

raidEnabled(8)

RAID redundant memory feature is enabled.

dddcCapable(16)

DDDC redundancy is enabled.

Table 16-7.

Physical Memory Logging Capabilities

Variable Name: DellPhysicalMemoryLoggingCapabilities
Data Type: Integer
Possible Data Values

Meaning of Data Value

If set to 0 (zero)

There are no logging capabilities.

unknown Capabilities(1)

Logging capabilities are unknown.

The logging capabilities are:
enableCapable(2)

Logging enable/disable using Simple Network
Management Protocol (SNMP) is supported.

Memory Group

389

Table 16-8. Physical Memory Logging Settings
Variable Name: DellPhysicalMemoryLoggingSettings
Data Type: Integer
Possible Data Values

Meaning of Data Value

If set to 0 (zero)

There are no logging settings enabled.

unknown Capabilities(1)

Logging capabilities are unknown.

The logging settings are:
enabled(2)

390

Memory Group

Logging is disabled (0), or enabled (1).

BIOS Setup Control Group

17

Basic Input/Output System (BIOS) Setup Control Group variables provide
information about the functions that the BIOS performs in your system.
This management information base (MIB) group includes variables for the
boot sequence, speakers, diskettes, ports, network interface controllers (NICs),
and the Wakeup on local area network (LAN) feature.

BIOS Setup Control Group Tables
The MIB tables in this group define the BIOS control of devices and
controller cards that are typically present in a system.
•

"BIOS Setup Control Table" on page 391

•

"SCSI Control Table" on page 402

•

"Parallel Port Control Table" on page 404

•

"Serial Port Control Table" on page 406

•

"USB Control Table" on page 408

•

"IDE Control Table" on page 410

•

"Diskette Control Table" on page 412

•

"Network Interface Control Table" on page 414

The following MIB table in the BIOS Setup Control Group is supported on
Dell PowerEdge xx2x (12G) systems:
•

"BIOS Setting Table" on page 417

BIOS Setup Control Table
Name

biosSetUpControlTable

Object ID

1.3.6.1.4.1.674.10892.1.1400.10

Description

Defines the set of single devices in a chassis controlled by the
BIOS.

Syntax

BiosSetUpControlTableEntry

BIOS Setup Control Group

391

Name

biosSetUpControlTable

Access

Not accessible

BIOS Setup Control Table Entry
Name

biosSetUpControlTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.1400.10.1

Description

Defines the BIOS Control Device Table entry.

Syntax

BiosSetUpControlTableEntry

Access

Not accessible

Index

biosSetUpControlchassisIndex

BIOS Setup Control Chassis Index
Name

biosSetUpControlchassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.1400.10.1.1

Description

Defines the index (one-based) of this chassis.

Syntax

DellObjectRange

Access

Read-only

BIOS Setup Control (BSUC) Pointing Device Control Capabilities
Name

bSUCpointingDeviceControlCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.1400.10.1.2

Description

Defines the capabilities of the pointing device.

Syntax

DellStateCapabilities

Access

Read-only

BIOS Setup Control Pointing Device Control Settings
Name

bSUCpointingDeviceControlSettings

Object ID

1.3.6.1.4.1.674.10892.1.1400.10.1.3

Description

Defines the state of the pointing device.

392

BIOS Setup Control Group

Name

bSUCpointingDeviceControlSettings

Syntax

DellStateSettings

Access

Read-write

BIOS Setup Control Pointing Device Control Status
Name

bSUCpointingDeviceControlStatus

Object ID

1.3.6.1.4.1.674.10892.1.1400.10.1.4

Description

Defines the status of the pointing device.

Syntax

DellStatus

Access

Read-only

BIOS Setup Control Pointing Device Control Name
Name

bSUCpointingDeviceControlName

Object ID

1.3.6.1.4.1.674.10892.1.1400.10.1.5

Description

Defines the setup BIOS name of the pointing device.

Syntax

DellString

Access

Read-only

BIOS Setup Control Numeric Lock Control Capabilities
Name

bSUCnumLockControlCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.1400.10.1.6

Description

Defines the capabilities of the numeric lock.

Syntax

DellStateCapabilities

Access

Read-only

BIOS Setup Control Numeric Lock Control Settings
Name

bSUCnumLockControlSettings

Object ID

1.3.6.1.4.1.674.10892.1.1400.10.1.7

Description

Defines the state of the numeric lock.

BIOS Setup Control Group

393

Name

bSUCnumLockControlSettings

Syntax

DellStateSettings

Access

Read-only

BIOS Setup Control Numeric Lock Control Status
Name

bSUCnumLockControlStatus

Object ID

1.3.6.1.4.1.674.10892.1.1400.10.1.8

Description

Defines the status of the numeric lock.

Syntax

DellStatus

Access

Read-only

BIOS Setup Control Numeric Lock Control Name
Name

bSUCnumLockControlName

Object ID

1.3.6.1.4.1.674.10892.1.1400.10.1.9

Description

Defines the setup BIOS name of the numeric lock.

Syntax

DellString

Access

Read-only

BIOS Setup Control Processor Serial Number Control Capabilities
Name

bSUCprocessorSerialNumberControlCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.1400.10.1.10

Description

Defines if the processor serial number can be returned.

Syntax

DellStateCapabilities

Access

Read-only

BIOS Setup Control Processor Serial Number Control Settings
Name

bSUCprocessorSerialNumberControlSettings

Object ID

1.3.6.1.4.1.674.10892.1.1400.10.1.11

Description

Defines the state of the processor serial number.

394

BIOS Setup Control Group

Name

bSUCprocessorSerialNumberControlSettings

Syntax

DellStateSettings

Access

Read-only

BIOS Setup Control Processor Serial Number Control Status
Name

bSUCprocessorSerialNumberControlStatus

Object ID

1.3.6.1.4.1.674.10892.1.1400.10.1.12

Description

Defines the status of the processor serial number.

Syntax

DellStatus

Access

Read-only

BIOS Setup Control Processor Serial Number Control Name
Name

bSUCprocessorSerialNumberControlName

Object ID

1.3.6.1.4.1.674.10892.1.1400.10.1.13

Description

Defines the setup BIOS name of the processor serial number.

Syntax

DellString

Access

Read-write

BIOS Setup Control Speaker Control Capabilities Unique
Name

bSUCspeakerControlCapabilitiesUnique

Object ID

1.3.6.1.4.1.674.10892.1.1400.10.1.14

Description

Defines the capabilities of the speaker control.

Syntax

DellSpeakerControlCapabilitiesUnique (See Table 17-1)

Access

Read-only

BIOS Setup Control Speaker Control Settings Unique
Name

bSUCspeakerControlSettingsUnique

Object ID

1.3.6.1.4.1.674.10892.1.1400.10.1.15

Description

Defines the settings available for speaker control.

BIOS Setup Control Group

395

Name

bSUCspeakerControlSettingsUnique

Syntax

DellSpeakerControlSettingsUnique (See Table 17-2)

Access

Read-only

BIOS Setup Control Speaker Control Status
Name

bSUCspeakerControlStatus

Object ID

1.3.6.1.4.1.674.10892.1.1400.10.1.16

Description

Defines the status of speaker control.

Syntax

DellStatus

Access

Read-only

BIOS Setup Control Speaker Control Name
Name

bSUCspeakerControlName

Object ID

1.3.6.1.4.1.674.10892.1.1400.10.1.17

Description

Defines the setup BIOS name of the speaker control.

Syntax

DellString

Access

Read-only

BIOS Setup Control NIF Wakeup on LAN Control Capabilities Unique
Name

bSUCnIFwakeonLanControlCapabilitiesUnique

Object ID

1.3.6.1.4.1.674.10892.1.1400.10.1.18

Description

Defines the defines the capabilities of the network interface
function (NIF) Wakeup on LAN.

Syntax

DellNIFwakeonLanControlCapabilitiesUnique (See Table 17-4)

Access

Read-only

BIOS Setup Control NIF Wakeup on LAN Control Settings Unique
Name

bSUCnIFwakeonLanControlSettingsUnique

Object ID

1.3.6.1.4.1.674.10892.1.1400.10.1.19

396

BIOS Setup Control Group

Name

bSUCnIFwakeonLanControlSettingsUnique

Description

Defines the state of the NIF Wakeup on LAN.

Syntax

DellNIFwakeonLanControlSettingsUnique (See Table 17-4)

Access

Read-only

BIOS Setup Control NIF Wakeup on LAN Control Status
Name

bSUCnIFwakeonLanControlStatus

Object ID

1.3.6.1.4.1.674.10892.1.1400.10.1.20

Description

Defines the status of the NIF Wakeup on LAN.

Syntax

DellStatus

Access

Read-only

BIOS Setup Control NIF Wakeup on LAN Control Name
Name

bSUCnIFwakeonLanControlName

Object ID

1.3.6.1.4.1.674.10892.1.1400.10.1.21

Description

Defines the setup BIOS name of the NIF Wakeup on LAN.

Syntax

DellString

Access

Read-only

BIOS Setup Control Boot Sequence Control Capabilities Unique
Name

bSUCbootSequenceControlCapabilitiesUnique

Object ID

1.3.6.1.4.1.674.10892.1.1400.10.1.22

Description

Defines the capabilities of the boot sequence.

Syntax

DellBootSequenceControlCapabilitiesUnique (See Table 17-5)

Access

Read-only

BIOS Setup Control Boot Sequence Control Settings Unique
Name

DellBootSequenceControlSettingsUnique

Object ID

1.3.6.1.4.1.674.10892.1.1400.10.1.23

BIOS Setup Control Group

397

Name

DellBootSequenceControlSettingsUnique

Description

Defines the state of the boot sequence.

Syntax

DellBootSequenceControlSettingsUnique (See Table 17-6)

Access

Read-only

BIOS Setup Control Boot Sequence Control Status
Name

bSUCbootSequenceControlStatus

Object ID

1.3.6.1.4.1.674.10892.1.1400.10.1.24

Description

Defines the status of the boot sequence.

Syntax

DellStatus

Access

Read-only

BIOS Setup Control Boot Sequence Control Name
Name

bSUCbootSequenceControlName

Object ID

1.3.6.1.4.1.674.10892.1.1400.10.1.25

Description

Defines the control name of the boot sequence.

Syntax

DellString

Access

Read-only

BIOS Setup Control Administrator Password Control Capabilities Unique
Name

bSUCadministratorPasswordControlCapabilities
Unique

Object ID

1.3.6.1.4.1.674.10892.1.1400.10.1.26

Description

Defines the capabilities of the administrator password control.

Syntax

DellBIOSPasswordControlCapabilitiesUnique

Access

Read-only

398

BIOS Setup Control Group

BIOS Setup Control Administrator Password Control Settings Unique
Name

bSUCadministratorPasswordControlSettingsUnique

Object ID

1.3.6.1.4.1.674.10892.1.1400.10.1.27

Description

Defines the settings for administrator password control.

Syntax

DellBIOSPasswordControlSettingsUnique (See Table 17-9)

Access

Read-write

BIOS Setup Control Administrator Password Control Status
Name

bSUCadministratorPasswordControlStatus

Object ID

1.3.6.1.4.1.674.10892.1.1400.10.1.28

Description

Defines the status for administrator password control.

Syntax

DellStatus

Access

Read-only

BIOS Setup Control Administrator Password Verify Name
Name

bSUCadministratorPasswordVerifyName

Object ID

1.3.6.1.4.1.674.10892.1.1400.10.1.29

Description

Defines the setup BIOS name for the current administrator password.

Syntax

DellString

Access

Read-write

BIOS Setup Control Administrator Password New Password Name
Name

bSUCadministratorPasswordNewPasswordName

Object ID

1.3.6.1.4.1.674.10892.1.1400.10.1.30

Description

Defines the setup BIOS name of the new administrator
password. To set a new administrator password, you must have
successfully set the current administrator password immediately
preceding this password change.

Syntax

DellString

Access

Read-write
BIOS Setup Control Group

399

BIOS Setup Control User Password Control Capabilities Unique
Name

bSUCuserPasswordControlCapabilitiesUnique

Object ID

1.3.6.1.4.1.674.10892.1.1400.10.1.31

Description

Defines the capabilities of user password control.

Syntax

DellBIOSPasswordControlCapabilitiesUnique

Access

Read-only

BIOS Setup Control User Password Control Settings Unique
Name

bSUCuserPasswordControlSettingsUnique

Object ID

1.3.6.1.4.1.674.10892.1.1400.10.1.32

Description

Defines the control settings for user password control.

Syntax

DellBIOSPasswordControlSettingsUnique (See Table 17-9)

Access

Read-write

BIOS Setup Control User Password Control Status
Name

bSUCuserPasswordControlStatus

Object ID

1.3.6.1.4.1.674.10892.1.1400.10.1.33

Description

Defines the status of the user password control.

Syntax

DellStatus

Access

Read-only

BIOS Setup Control User Password Verify Name
Name

bSUCuserPasswordVerifyName

Object ID

1.3.6.1.4.1.674.10892.1.1400.10.1.34

Description

Defines the setup BIOS name of the current user password.

Syntax

DellString

Access

Read-write

400

BIOS Setup Control Group

BIOS Setup Control User Password New Password Name
Name

bSUCuserPasswordNewPasswordName

Object ID

1.3.6.1.4.1.674.10892.1.1400.10.1.35

Description

Defines the setup BIOS name of the new user password. To set a
new user password, a you must have successfully set the current
user password immediately preceding this password change.

Syntax

DellString

Access

Read-write

BIOS Setup Control TPM Security Control Capabilities
Name

bSUCtpmSecurityControlCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.1400.10.1.36

Description

Defines the BIOS setup control capabilities of Trusted Platform
Module (TPM) security.

Syntax

DellTPMSecurityControlCapabilities

Access

Read-only

BIOS Setup Control TPM Security Control Setting
Name

bSUCtpmSecurityControlSetting

Object ID

1.3.6.1.4.1.674.10892.1.1400.10.1.37

Description

Defines the BIOS setup control setting of Trusted Platform
Module (TPM) security.

Syntax

DellTPMSecurityControlSetting

Access

Read-only

BIOS Setup Control TPM Security Control Status
Name

bSUCtpmSecurityControlStatus

Object ID

1.3.6.1.4.1.674.10892.1.1400.10.1.38

Description

Defines the BIOS setup control status of Trusted Platform
Module (TPM) security.

Syntax

DellStatus

Access

Read-only
BIOS Setup Control Group

401

BIOS Setup Control TPM Security Control Name
Name

bSUCtpmSecurityControlName

Object ID

1.3.6.1.4.1.674.10892.1.1400.10.1.39

Description

Defines the BIOS setup control name of Trusted Platform
Module (TPM) security.

Syntax

DellString

Access

Read-only

SCSI Control Table
Name

sCSIControlTable

Object ID

1.3.6.1.4.1.674.10892.1.1400.20

Description

Defines the Small Computer System Interface (SCSI) Control Table.

Syntax

SCSIControlTableEntry

Access

Not accessible

SCSI Control Table Entry
Name

sCSIControlTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.1400.20.1

Description

Defines the SCSI Control Table entry.

Syntax

SCSIControlTableEntry

Access

Not accessible

Index

sCSIControlchassisIndex, sCSIControlIndex

SCSI Control Chassis Index
Name

sCSIControlchassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.1400.20.1.1

Description

Defines the index (one-based) of this chassis.

Syntax

DellObjectRange

Access

Read-only

402

BIOS Setup Control Group

SCSI Control Index
Name

sCSIControlIndex

Object ID

1.3.6.1.4.1.674.10892.1.1400.20.1.2

Description

Defines the index (one-based) of the SCSI controller in this chassis.

Syntax

DellObjectRange

Access

Read-only

SCSI Control Capabilities
Name

sCSIControlCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.1400.20.1.3

Description

Defines the capabilities of the SCSI controller.

Syntax

DellStateCapabilities

Access

Read-only

SCSI Control Settings
Name

sCSIControlSettings

Object ID

1.3.6.1.4.1.674.10892.1.1400.20.1.4

Description

Defines the state of the SCSI controller.

Syntax

DellStateSettings

Access

Read-only

SCSI Control Status
Name

sCSIControlStatus

Object ID

1.3.6.1.4.1.674.10892.1.1400.20.1.5

Description

Defines the status of the SCSI controller.

Syntax

DellStatus

Access

Read-only

BIOS Setup Control Group

403

SCSI Control Name
Name

sCSIControlName

Object ID

1.3.6.1.4.1.674.10892.1.1400.20.1.6

Description

Defines the setup BIOS name of the SCSI controller.

Syntax

DellString

Access

Read-only

Parallel Port Control Table
Name

parallelPortControlTable

Object ID

1.3.6.1.4.1.674.10892.1.1400.30

Description

Defines the Parallel Port Control Table.

Syntax

ParallelPortControlTableEntry

Access

Not accessible

Parallel Port Control Table Entry
Name

parallelPortControlTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.1400.30.1

Description

Defines the Parallel Port Control Table entry.

Syntax

ParallelPortControlTableEntry

Access

Not accessible

Index

parallelPortControlchassisIndex, parallelPortControlIndex

Parallel Port Control Chassis Index
Name

parallelPortControlchassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.1400.30.1.1

Description

Defines the index (one-based) of this chassis.

Syntax

DellObjectRange

Access

Read-only

404

BIOS Setup Control Group

Parallel Port Control Index
Name

parallelPortControlIndex

Object ID

1.3.6.1.4.1.674.10892.1.1400.30.1.2

Description

Defines the index (one-based) of the parallel port in this chassis.

Syntax

DellObjectRange

Access

Read-only

Parallel Port Control Capabilities Unique
Name

parallelPortControlCapabilitiesUnique

Object ID

1.3.6.1.4.1.674.10892.1.1400.30.1.3

Description

Defines the capabilities of the parallel port.

Syntax

DellParallelPortControlCapabilitiesUnique (See Table 17-12)

Access

Read-only

Parallel Port Control Settings Unique
Name

parallelPortControlSettingsUnique

Object ID

1.3.6.1.4.1.674.10892.1.1400.30.1.4

Description

Defines the state of the parallel port.

Syntax

DellParallelPortControlSettingsUnique (See Table 17-13)

Access

Read-only

Parallel Port Control Status
Name

parallelPortControlStatus

Object ID

1.3.6.1.4.1.674.10892.1.1400.30.1.5

Description

Defines the status of the parallel port.

Syntax

DellStatus

Access

Read-only

BIOS Setup Control Group

405

Parallel Port Control Name
Name

parallelPortControlName

Object ID

1.3.6.1.4.1.674.10892.1.1400.30.1.6

Description

Defines the setup BIOS name of the parallel port.

Syntax

DellString

Access

Read-only

Parallel Port Control Mode Capabilities Unique
Name

parallelPortControlModeCapabilitiesUnique

Object ID

1.3.6.1.4.1.674.10892.1.1400.30.1.7

Description

Defines the mode capabilities of the parallel port.

Syntax

DellParallelPortControlModeCapabilitiesUnique (See Table 17-14)

Access

Read-only

Parallel Port Control Mode Settings Unique
Name

parallelPortControlModeSettingsUnique

Object ID

1.3.6.1.4.1.674.10892.1.1400.30.1.8

Description

Defines the mode settings of the parallel port.

Syntax

DellParallelPortControlModeSettingsUnique (See Table 17-14)

Access

Read-write

Serial Port Control Table
Name

serialPortControlTable

Object ID

1.3.6.1.4.1.674.10892.1.1400.40

Description

Defines the Serial Port Control Table.

Syntax

SerialPortControlTableEntry

Access

Not accessible

406

BIOS Setup Control Group

Serial Port Control Table Entry
Name

serialPortControlTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.1400.40.1

Description

Defines the Serial Port Control Table entry.

Syntax

SerialPortControlTableEntry

Access

Not accessible

Index

serialPortControlchassisIndex, serialPortControlIndex

Serial Port Control Chassis Index
Name

serialPortControlchassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.1400.40.1.1

Description

Defines index (one-based) of this chassis.

Syntax

DellObjectRange

Access

read-only

Serial Port Control Index
Name

serialPortControlIndex

Object ID

1.3.6.1.4.1.674.10892.1.1400.40.1.2

Description

Defines the index (one-based) of the serial port in this chassis.

Syntax

DellObjectRange

Access

read-only

Serial Port Control Capabilities Unique
Name

serialPortControlCapabilitiesUnique

Object ID

1.3.6.1.4.1.674.10892.1.1400.40.1.3

Description

Defines the capabilities of the serial port.

Syntax

DellSerialPortControlCapabilitiesUnique (See Table 17-15)

Access

Read-only

BIOS Setup Control Group

407

Serial Port Control Settings Unique
Name

serialPortControlSettingsUnique

Object ID

1.3.6.1.4.1.674.10892.1.1400.40.1.4

Description

Defines the settings of the serial port.

Syntax

DellSerialPortControlSettingsUnique (See Table 17-16)

Access

Read-only

Serial Port Control Status
Name

serialPortControlStatus

Object ID

1.3.6.1.4.1.674.10892.1.1400.40.1.5

Description

Defines the status of the serial port.

Syntax

DellStatus

Access

Read-only

Serial Port Control Name
Name

serialPortControlName

Object ID

1.3.6.1.4.1.674.10892.1.1400.40.1.6

Description

Defines the setup BIOS name of the serial port.

Syntax

DellString

Access

Read-only

USB Control Table
These objects enable you to track the attributes of your Universal Serial Bus (USB).
Name

usbControlTable

Object ID

1.3.6.1.4.1.674.10892.1.1400.50

Description

Defines the USB Table.

Syntax

UsbControlTableEntry

Access

Not accessible

408

BIOS Setup Control Group

USB Control Table Entry
Name

usbControlTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.1400.50.1

Description

Defines the USB Table entry.

Syntax

UsbControlTableEntry

Access

Not accessible

Index

usbControlchassisIndex, usbControlIndex

USB Control Chassis Index
Name

usbControlchassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.1400.50.1.1

Description

Defines index (one-based) of this chassis.

Syntax

DellObjectRange

Access

Read-only

USB Control Index
Name

usbControlIndex

Object ID

1.3.6.1.4.1.674.10892.1.1400.50.1.2

Description

Defines the index (one-based) of the USB in this chassis.

Syntax

DellObjectRange

Access

Read-only

USB Control Capabilities
Name

usbControlCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.1400.50.1.3

Description

Defines the capabilities of the USB.

Syntax

DellStateCapabilities

Access

Read-only

BIOS Setup Control Group

409

USB Control Settings
Name

usbControlSettings

Object ID

1.3.6.1.4.1.674.10892.1.1400.50.1.4

Description

Defines the control settings for the USB.

Syntax

DellStateSettings

Access

Read-only

USB Control Status
Name

usbControlStatus

Object ID

1.3.6.1.4.1.674.10892.1.1400.50.1.5

Description

Defines the status of the USB.

Syntax

DellStatus

Access

Read-only

USB Control Name
Name

usbControlName

Object ID

1.3.6.1.4.1.674.10892.1.1400.50.1.6

Description

Defines the setup BIOS name of the USB.

Syntax

DellString

Access

Read-only

IDE Control Table
These objects enable you to track the attributes of Integrated Device
Electronics (IDE) controller cards in your system.
Name

ideControlTable

Object ID

1.3.6.1.4.1.674.10892.1.1400.60

Description

Defines the IDE Control Table.

Syntax

IdeControlTableEntry

Access

Not accessible

410

BIOS Setup Control Group

IDE Control Table Entry
Name

ideControlTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.1400.60.1

Description

Defines the IDE Control Table entry.

Syntax

IdeControlTableEntry

Access

Not accessible

Index

ideControlchassisIndex, ideControlIndex

IDE Control Chassis Index
Name

ideControlchassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.1400.60.1.1

Description

Defines the index (one-based) of this chassis.

Syntax

DellObjectRange

Access

Read-only

IDE Control Index
Name

ideControlIndex

Object ID

1.3.6.1.4.1.674.10892.1.1400.60.1.2

Description

Defines the index (one-based) of the IDE controller in this chassis.

Syntax

DellObjectRange

Access

Read-only

IDE Control Capabilities Unique
Name

ideControlCapabilitiesUnique

Object ID

1.3.6.1.4.1.674.10892.1.1400.60.1.3

Description

Defines the capabilities of the IDE controller.

Syntax

DellideControlCapabilitiesUnique (See Table 17-17)

Access

Read-only

BIOS Setup Control Group

411

IDE Control Settings Unique
Name

ideControlSettingsUnique

Object ID

1.3.6.1.4.1.674.10892.1.1400.60.1.4

Description

Defines the settings for the IDE controller.

Syntax

DellideControlCapabilitiesUnique (See Table 17-17)

Access

Read-only

IDE Control Status
Name

ideControlStatus

Object ID

1.3.6.1.4.1.674.10892.1.1400.60.1.5

Description

Defines the status for the IDE controller.

Syntax

DellStatus

Access

Read-only

IDE Control Name
Name

ideControlName

Object ID

1.3.6.1.4.1.674.10892.1.1400.60.1.6

Description

Defines the setup BIOS name for the IDE controller.

Syntax

DellStatus

Access

Read-only

Diskette Control Table
Name

disketteControlTable

Object ID

1.3.6.1.4.1.674.10892.1.1400.70

Description

Defines the Diskette Control Table.

Syntax

DisketteControlTableEntry

Access

Not accessible

412

BIOS Setup Control Group

Diskette Control Table Entry
Name

disketteControlTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.1400.70.1

Description

Defines the Diskette Control Table entry.

Syntax

DellStatus

Access

Not accessible

Index

disketteControlchassisIndex, disketteControlIndex

Diskette Control Chassis Index
Name

disketteControlchassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.1400.70.1.1

Description

Defines the index (one-based) of this chassis.

Syntax

DellObjectRange

Access

Read-only

Diskette Control Index
Name

disketteControlIndex

Object ID

1.3.6.1.4.1.674.10892.1.1400.70.1.2

Description

Defines the index of the diskette controllers in this chassis.

Syntax

DellObjectRange

Access

Read-only

Diskette Control Capabilities Unique
Name

disketteControlCapabilitiesUnique

Object ID

1.3.6.1.4.1.674.10892.1.1400.70.1.3

Description

Defines the capabilities of the diskette controller.

Syntax

DellDisketteControlCapabilitiesUnique (See Table 17-18)

Access

Read-only

BIOS Setup Control Group

413

Diskette Control Settings Unique
Name

disketteControlSettingsUnique

Object ID

1.3.6.1.4.1.674.10892.1.1400.70.1.4

Description

Defines the control settings for the diskette controller.

Syntax

DellDisketteControlSettingsUnique

Access

Read-only

Diskette Control Status
Name

disketteControlStatus

Object ID

1.3.6.1.4.1.674.10892.1.1400.70.1.5

Description

Defines the status of the diskette controller.

Syntax

DellStatus

Access

Read-only

Diskette Control Name
Name

disketteControlName

Object ID

1.3.6.1.4.1.674.10892.1.1400.70.1.6

Description

Defines the setup BIOS name of the diskette controller.

Syntax

DellString

Access

Read-only

Network Interface Control Table
These MIB objects enable you to track the attributes of the NIC card for your
system.
Name

networkInterfaceControlTable

Object ID

1.3.6.1.4.1.674.10892.1.1400.80

Description

Defines the Network Interface Control Table.

Syntax

NetworkInterfaceControlTableEntry

Access

Not accessible

414

BIOS Setup Control Group

Network Interface Control Table Entry
Name

networkInterfaceControlTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.1400.80.1

Description

Defines the Network Interface Control Table entry.

Syntax

NetworkInterfaceControlTableEntry

Access

Not accessible

Index

networkInterfaceControlchassisIndex,
networkInterfaceControlIndex

Network Interface Control Chassis Index
Name

networkInterfaceControlchassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.1400.80.1.1

Description

Defines the index (one-based) of this chassis.

Syntax

DellObjectRange

Access

Read-only

Network Interface Control Index
Name

networkInterfaceControlIndex

Object ID

1.3.6.1.4.1.674.10892.1.1400.80.1.2

Description

Defines the index (one-based) of the network interface
controller in this chassis.

Syntax

DellObjectRange

Access

Read-only

BIOS Setup Control Group

415

Network Interface Control Capabilities Unique
Name

networkInterfaceControlCapabilitiesUnique

Object ID

1.3.6.1.4.1.674.10892.1.1400.80.1.3

Description

Defines the capabilities of the NIC.

Syntax

DellNetworkInterfaceControlCapabilitiesUnique (See Table 17-19)

Access

Read-only

Network Interface Control Settings Unique
Name

networkInterfaceControlSettingsUnique

Object ID

1.3.6.1.4.1.674.10892.1.1400.80.1.4

Description

Defines the control settings for the NIC.

Syntax

DellNetworkInterfaceControlSettingsUnique (See Table 17-20)

Access

Read-write

Network Interface Control Status
Name

networkInterfaceControlStatus

Object ID

1.3.6.1.4.1.674.10892.1.1400.80.1.5

Description

Defines the status of the NIC.

Syntax

DellStatus

Access

Read-only

Network Interface Control Name
Name

networkInterfaceControlName

Object ID

1.3.6.1.4.1.674.10892.1.1400.80.1.6

Description

Defines the setup BIOS name of the NIC.

Syntax

DellString

Access

Read-only

416

BIOS Setup Control Group

BIOS Setting Table
These MIB objects enable you to track the BIOS settings for your system.
NOTE: These MIB objects are supported on Dell PowerEdge xx2x systems.
Name

biosSettingTable

Object ID

1.3.6.1.4.1.674.10892.1.1400.90

Description

Defines the BIOS Setting Table.

Syntax

SEQUENCE OF BiosSettingTableEntry

Access

Not accessible

BIOS Setting Table Entry
Name

biosSettingTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.1400.90.1

Description

Defines the BIOS Setting Table Entry.

Syntax

BiosSettingTableEntry

Access

Not accessible

Index

biosSettingChassisIndex,
biosSettingIndex

BIOS Setting Chassis Index
Name

biosSettingChassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.1400.90.1.1

Description

Defines the index (one based) of the associated chassis.

Syntax

DellObjectRange

Access

Read-only

BIOS Setting Index
Name

biosSettingIndex

Object ID

1.3.6.1.4.1.674.10892.1.1400.90.1.2

BIOS Setup Control Group

417

Description

Defines the index (one based) of the BIOS setting.

Syntax

DellObjectRange

Access

Read-only

BIOS Setting Name
Name

biosSettingName

Object ID

1.3.6.1.4.1.674.10892.1.1400.90.1.3

Description

Defines the name of the BIOS setting.

Syntax

DisplayString

Access

Read-only

BIOS Setting Display Name
Name

biosSettingDisplayName

Object ID

1.3.6.1.4.1.674.10892.1.1400.90.1.4

Description

Defines the display name of the BIOS setting.

Syntax

DisplayString

Access

Read-only

BIOS Setting Value Type
Name

biosSettingValueType

Object ID

1.3.6.1.4.1.674.10892.1.1400.90.1.5

Description

Defines the type of the BIOS setting value.

Syntax

DellBIOSSettingValueType

Access

Read-only

BIOS Setting Current Value
Name

biosSettingCurrentValue

Object ID

1.3.6.1.4.1.674.10892.1.1400.90.1.6

Description

Defines the current value of the BIOS setting.

418

BIOS Setup Control Group

Syntax

DisplayString

Access

Read-only

BIOS Setting Pending Value
Name

biosSettingPendingValue

Object ID

1.3.6.1.4.1.674.10892.1.1400.90.1.7

Description

Defines the pending value of the BIOS setting.

Syntax

DisplayString

Access

Read-only

BIOS Setting Default Value
Name

biosSettingDefaultValue

Object ID

1.3.6.1.4.1.674.10892.1.1400.90.1.8

Description

Defines the default value of the BIOS setting.

Syntax

DisplayString

Access

Read-only

BIOS Setting Possible Values
Name

biosSettingPossibleValues

Object ID

1.3.6.1.4.1.674.10892.1.1400.90.1.9

Description

Defines the possible values of the BIOS setting.

Syntax

DisplayString

Access

Read-only

BIOS Setting Display Order
Name

biosSettingDisplayOrder

Object ID

1.3.6.1.4.1.674.10892.1.1400.90.1.10

Description

Defines the recommended display order of the BIOS setting
within its BIOS setting group.

BIOS Setup Control Group

419

Syntax

DellUnsigned32BitRange

Access

Read-only

BIOS Setting Group Display Name
Name

biosSettingGroupDisplayName

Object ID

1.3.6.1.4.1.674.10892.1.1400.90.1.11

Description

Defines the display name of the BIOS setting group for the
BIOS setting.

Syntax

DisplayString

Access

Read-only

BIOS Setting FQDD
Name

biosSettingFQDD

Object ID

1.3.6.1.4.1.674.10892.1.1400.90.1.12

Description

Fully Qualified Device Descriptor (FQDD) for the BIOS setting.

Syntax

DisplayString

Access

Read-only

BIOS Group Variable Values
This section includes definitions for server administrator-specific variable
values used in this section.
Table 17-1. Speaker Control Capabilities Unique
Variable Name: DellSpeakerControlCapabilitiesUnique
Data Type: Integer
Possible Data Values

Meaning of Data Value

unknown(1)

Speaker control capabilities are unknown.

enableCapable(2)

Setup BIOS can enable speaker control.

lowCapable(4)

Setup BIOS can set the speaker volume to low.

mediumCapable(8)

Setup BIOS can set the speaker volume to medium.

420

BIOS Setup Control Group

Table 17-1.

Speaker Control Capabilities Unique (continued)

Variable Name: DellSpeakerControlCapabilitiesUnique
Data Type: Integer
Possible Data Values

Meaning of Data Value

highCapable(16)

Setup BIOS can set the speaker volume to high.

allVolumeCapable(30)

Setup BIOS can set the speaker volume to any of the
three settings.

Table 17-2.

Speaker Control Settings Unique

Variable Name: DellSpeakerControlSettingsUnique
Data Type: Integer
Possible Data Values

Meaning of Data Value

unknown(1)

Speaker control state is unknown.

enabled(2)

Speaker control is enabled.

low(4)

Speaker control volume is low.

medium(8)

Speaker control volume is medium.

high(16)

Speaker control volume is high.

Table 17-3.

Network Interface (NIF) Wakeup on LAN Capabilities Unique

Variable Name: DellNIFwakeonLanControlCapabilitiesUnique
Data Type: Integer
Possible Data Values

Meaning of Data Value

unknown(1)

Setup BIOS Wakeup on LAN
capabilities are unknown.

enableCapable(2)

Setup BIOS is capable of enabling the
NIF Wakeup on LAN.

addInCardCapable(4)

Setup BIOS is capable of enabling
Wakeup on LAN by option card.

onBoardCapable(8)

Setup BIOS is capable of enabling
Wakeup on LAN by integrated NIF.

BIOS Setup Control Group

421

Table 17-3. Network Interface (NIF) Wakeup on LAN Capabilities Unique (continued)
Variable Name: DellNIFwakeonLanControlCapabilitiesUnique
Data Type: Integer
Possible Data Values

Meaning of Data Value

bothCapable(14)

Setup BIOS is capable of enabling
Wakeup on LAN by either option card or
integrated NIF.

Table 17-4. NIF Wakeup on LAN Control Settings Unique
Variable Name: DellNIFwakeonLanControlSettingsUnique
Data Type: Integer
Possible Data Values

Meaning of Data Value

unknown(1)

NIF Wakeup on LAN state is unknown.

enabled(2)

NIF Wakeup on LAN is enabled.

addInCard(4)

NIF Wakeup on LAN is by option card.

onBoard(8)

NIF Wakeup on LAN is by integrated NIF.

addInCardOrOnBoard(12)

NIF Wakeup on LAN is by option card or
integrated NIF.

Table 17-5. Boot Sequence Control Capabilities Unique
Variable Name: DellBootSequenceControlCapabilitiesUnique
Data Type: Integer
Possible Data Values

Meaning of Data Value

bootSequenceUnknown(1)

Boot sequence capabilities are unknown.

bootFromDisketteFirstCapable Setup BIOS can boot from a diskette
(2)
first.
bootFromhardDriveFirstCapable Setup BIOS can boot from an IDE hard
(4)
drive first.
bootFromDisketteORHardDrive Setup BIOS can boot from a diskette or
FirstCapable(6)
an IDE hard drive first.

422

BIOS Setup Control Group

Table 17-5.

Boot Sequence Control Capabilities Unique (continued)

Variable Name: DellBootSequenceControlCapabilitiesUnique
Data Type: Integer
Possible Data Values

Meaning of Data Value

bootFromDeviceListCapable(8) Setup BIOS can boot from a device list.
bootFromCDROMFirstCapable(16) Setup BIOS can boot from a CD first.
allFirstCapable(30)

Table 17-6.

Setup BIOS can boot by any of the
preceding methods first.

Boot Sequence Control Settings Unique

Variable Name: DellBootSequenceControlSettingsUnique
Data Type: Integer
Possible Data Values

Meaning of Data Value

bootSequenceUnknown(1)

Boot sequence state is unknown.

bootFromDisketteFirst(2)

Setup BIOS is set to boot by
diskette first.

bootFromHardDriveFirst(4)

Setup BIOS is set to boot by IDE
hard drive first.

bootFromDeviceList(8)

Setup BIOS is set to boot by a
device list.

bootFromCDROMFirst(16)

Setup BIOS is set to boot by CD
first.

Table 17-7.

BIOS Password Control Capabilities

Variable Name: DellBIOSPasswordControlCapabilities
Data Type: Integer
Possible Data Values

Meaning of Data Value

passwordControlCapabilitiesUn BIOS password capabilities are
known(1)
unknown.
passwordControlEnableCapable
(2)

Setup BIOS is capable of enabling
password changes.
BIOS Setup Control Group

423

Table 17-7. BIOS Password Control Capabilities (continued)
Variable Name: DellBIOSPasswordControlCapabilities
Data Type: Integer
Possible Data Values

Meaning of Data Value

passwordControlJumperDisable
Capable(4)

Setup BIOS is capable of
determining if password control can
be jumper disabled.

passwordControlEnableANDJumper Setup BIOS is capable of enabling
DisableCapable(6)
password changes and of
determining if password control can
be jumper disabled.
Table 17-8. BIOS Password Control Settings Unique
Variable Name: DellBIOSPasswordControlSettingsUnique
Data Type: Integer
Possible Data Values

Meaning of Data Value

passwordControlSettingsUnknown(1) Setup BIOS password state is
unknown.
passwordControlEnabled(2)

Setup BIOS has password changes
enabled.

passwordControlJumperDisabled(4)

Setup BIOS has determined that
password control has been disabled
by a jumper.

Table 17-9. BIOS Password Control Settings
Variable Name: DellBIOSPasswordControlSettingsUnique
Data Type: Integer
Possible Data Values

Meaning of Data Value

passwordControlSettingsUnknown(1) Setup BIOS password state is
unknown.
passwordControlEnabled(2)

424

BIOS Setup Control Group

Setup BIOS has password changes
enabled.

Table 17-9.

BIOS Password Control Settings (continued)

Variable Name: DellBIOSPasswordControlSettingsUnique
Data Type: Integer
Possible Data Values

Meaning of Data Value

passwordControlJumperDisabled(4)

Setup BIOS has determined that
password control has been
disabled by a jumper.

Table 17-10. TPM Security Control Capabilities
Variable Name: DellTPMSecurityControlCapabilities
Data Type: Integer
Possible Data Values

Meaning of Data Value

offCapable(1)

TPM security can be Off.

onWithPrebootMeasurementsCap TPM security can be On with Pre-boot
able(2)
Measurements.
onWithoutPrebootMeasurements TPM security can be On without Pre-boot
Capable(4)
Measurements.
Table 17-11. TPM Security Control Setting
Variable Name: DellTPMSecurityControlSetting
Data Type: Integer
Possible Data Values

Meaning of Data Value

off(0)

TPM security is Off.

onWithPrebootMeasurements(1) TPM security is On with Pre-boot
Measurements.
onWithoutPrebootMeasurements TPM security is On without Pre-boot
(2)
Measurements.

BIOS Setup Control Group

425

Table 17-12. Parallel Port Control Capabilities
Variable Name: DellParallelPortControlCapabilitiesUnique
Data Type: Integer
Possible Data Values

Meaning of Data Value

unknown(1)

Setup BIOS parallel port capabilities
are unknown.

enableCapable(2)

Setup BIOS can enable the parallel port.

lpt1Capable(4)

Setup BIOS can support parallel port 1.

lpt1andEnableCapable(6)

Setup BIOS has enabled parallel port 1.

lpt2Capable(8)

Setup BIOS can support parallel port 2.

lpt2andEnableCapable(10)

Setup BIOS has enabled parallel port 2.

lpt3Capable(16)

Setup BIOS can support parallel port 3.

lpt3andEnableCapable(18)

Setup BIOS has enabled parallel port 3.

allParallelPortCapable(30)

Setup BIOS can support any of the three
parallel ports.

Table 17-13. Parallel Port Control Settings
Variable Name: DellParallelPortControlSettingsUnique
Data Type: Integer
Possible Data Values

Meaning of Data Value

unknown(1)

Parallel port state is unknown.

enabled(2)

Setup BIOS has enabled the parallel port.

lpt1(4)

Setup BIOS supports parallel port 1.

lpt1Enabled(6)

Setup BIOS has enabled parallel port 1.

lpt2(8)

Setup BIOS supports parallel port 2.

lpt2Enabled(10)

Setup BIOS has enabled parallel port 2.

lpt3(16)

Setup BIOS supports parallel port 3.

426

BIOS Setup Control Group

Table 17-14. Parallel Port Control Mode Settings
Variable Name: DellParallelPortControlModeSettingsUnique
Data Type: Integer
Possible Data Values

Meaning of Data Value

unknown(1)

Parallel port mode is unknown.

atModeEnabled(2)

Setup BIOS has set the parallel port to AT mode.

ps2ModeEnabled(4)

Setup BIOS has set the parallel port to Personal
Systems/2 (PS/2) mode.

ecpModeEnabled(8)

Setup BIOS has set the parallel port to Extended
Capabilities Port (ECP) mode.

eppModeEnabled(16)

Setup BIOS has set the parallel port to Enhanced
Parallel Port (EPP) mode.

Table 17-15. Serial Port Control Capabilities
Variable Name: DellSerialPortControlCapabilitiesUnique
Data Type: Integer
Possible Data Values

Meaning of Data Value

unknown(1)

Setup BIOS serial port capabilities are
unknown.

enableCapable(2)

Setup BIOS can enable the serial port.

com1Capable(4)

Setup BIOS can support serial port 1.

enableAndCom1Capable(6)

Setup BIOS can enable serial port 1.

com2Capable(8)

Setup BIOS can support serial port 2.

enableAndCom2Capable(10) Setup BIOS is capable of enabling serial port 2.
com3Capable(16)

Setup BIOS can support serial port 3.

enableAndCom3Capable(18) Setup BIOS is capable of enabling serial port 3.
com4Capable(32)

Setup BIOS can support serial port 4.

enableAndCom4Capable(34) Setup BIOS is capable of enabling serial port 4.
autoConfigCapable(64)

Setup BIOS is capable of autoconfiguring all
serial ports.
BIOS Setup Control Group

427

Table 17-15. Serial Port Control Capabilities (continued)
Variable Name: DellSerialPortControlCapabilitiesUnique
Data Type: Integer
Possible Data Values

Meaning of Data Value

com1OrCom3CapableAndAuto Setup BIOS has enabled autoconfiguration of
ConfigCapable(86)
COM1 and COM3 serial ports.
com2OrCom4CapableAndAuto Setup BIOS has enabled autoconfiguration of
ConfigCapable(106)
COM2 and COM4 serial ports.
allcomCapable(126)

Setup BIOS is capable of enabling or
autoconfiguring all serial ports.

Table 17-16. Serial Port Control Settings
Variable Name: DellSerialPortControlSettingsUnique
Data Type: Integer
Possible Data Values

Meaning of Data Value

unknown(1)

Serial port state is unknown.

enabled(2)

Setup BIOS has enabled the serial port.

com1(4)

Setup BIOS has selected serial port 1.

com1Enabled(6)

Setup BIOS has enabled serial port 1.

com2(8)

Setup BIOS has selected serial port 2.

com2Enabled(10)

Setup BIOS has enabled serial port 2.

com3(16)

Setup BIOS has selected serial port 3.

com3Enabled(18)

Setup BIOS has enabled serial port 3.

com4(32)

Setup BIOS has selected serial port 4.

com4Enabled(34)

Setup BIOS has enabled serial port 4.

comPortsAutoConfig(64)

Setup BIOS has selected autoconfiguration
of serial ports.

enabledAndAutoConfig(66) Setup BIOS has enabled autoconfiguration
of serial ports.

428

BIOS Setup Control Group

Table 17-17. IDE Control Capabilities
Variable Name: DellideControlCapabilitiesUnique
Data Type: Integer
Possible Data Values

Meaning of Data Value

unknown(1)

IDE control capabilities are unknown.

ideControlAutoConfigOrEnable IDE controller is autoconfigurable or
Capable(2)
enable capable.
Table 17-18. Diskette Control Settings
Variable Name: DellDisketteControlSettingsUnique
Data Type: Integer
Possible Data Values

Meaning of Data Value

unknown(1)

Diskette control state is unknown.

disketteControlAutoConfigEnabled Diskette control is set as
OrEnabled(2)
autoconfigurable or enabled.
Table 17-19. Network Interface Control Capabilities
Variable Name:

DellNetworkInterfaceControlCapabilitiesUnique
Data Type: Integer
Possible Data Values

Meaning of Data Value

unknown(1)

Unknown setup BIOS network interface
capabilities.

enableCapable(2)

Setup BIOS is capable of enabling the
network interface.

enableWithoutPXECapable(4)

Setup BIOS is capable of enabling the
NIF without Pre-boot eXecution
Environment (PXE).

BIOS Setup Control Group

429

Table 17-20. Network Interface Control Settings
Variable Name: DellNetworkInterfaceControlSettingsUnique
Data Type: Integer
Possible Data Values

Meaning of Data Value

unknown(1)

Network interface state is unknown.

enabled(2)

Network interface is enabled.

enabledWithoutPXE(4)

Network interface is enabled without PXE.

Table 17-21. BIOS Setting Value Type
Variable Name: DellBIOSSettingValueType
Data Type: Integer
Possible Data Values

Meaning of Data Value

integer(1)

Value type is integer.

string(2)

Value type is string.

enumeration(3)

Value type is enumeration.

orderedList(4)

Value type is ordered list.

430

BIOS Setup Control Group

Local Response Agent Group

18

The Local Response Agent Group provides information about various
attributes of your system’s local response agent (LRA). The LRA allows
systems managers to predetermine how a system running the server
administrator responds to a particular event type, such as the loss of
redundancy in a specific component or the elevation of temperature in a
chassis. Systems managers can configure the LRA to respond to an event type
with a specific action. When the condition of the critical component worsens,
the systems manager can escalate the response to make it more obvious to the
operator.
For example, when a voltage probe on a monitored machine reaches a
warning condition, the systems manager may want to notify the operator by
causing the machine to beep. When the voltage probe reaches failure, the
systems manager might want to have the system that has a failing component
send a broadcast message to the management system and power off the
troubled system.

LRA Group Tables
The following management information base (MIB) tables define
LRA variable attributes:
•

"LRA Global Settings Table" on page 432

•

"LRA Action Table" on page 434

LRA Global Settings
The global settings table allows the systems manager to determine what
LRA capabilities exist for a specific system that is running Server Administrator.
Some machines may support all or some of the capabilities described in
DellLocalResponseAgentCapabilitiesUnique. The LRA Global Settings Table
also defines thermal shutdown capabilities and settings. In the event that a
temperature probe determines the temperature is at or over the failure limit,
the systems manager can set an action to be taken automatically.

Local Response Agent Group

431

LRA Global Settings Table
Name

lRAGlobalSettingsTable

Object ID

1.3.6.1.4.1.674.10892.1.1500.10

Description

Defines the LRA Global Settings Table.

Syntax

SEQUENCE OF LRAGlobalSettingsTableEntry

Access

Not accessible

LRA Global Settings Table Entry
Name

lRAGlobalSettingsTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.1500.10.1

Description

Defines the LRA Global Settings Table entry.

Syntax

LRAGlobalSettingsTableEntry

Access

Not accessible

Index

lRAGlobalchassisIndex

LRA Global Chassis Index
Name

lRAGlobalchassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.1500.10.1.1

Description

Defines the index (one-based) of this chassis.

Syntax

DellObjectRange

Access

Read-only

LRA Global State
Name

lRAGlobalState

Object ID

1.3.6.1.4.1.674.10892.1.1500.10.1.2

Description

Defines the state of the LRA global settings.

Syntax

DellStateSettings

Access

Read-only

432

Local Response Agent Group

LRA Global Settings Disable Time-out Value
Name

lRAGlobalSettingsDisableTimeoutValue

Object ID

1.3.6.1.4.1.674.10892.1.1500.10.1.3

Description

Defines the time-out duration countdown, in seconds, that the
LRA global settings are disabled after a system shutdown and reboot.

Syntax

DellUnsigned32BitRange

Access

Read-only

LRA Global Settings Capabilities Unique
Name

lRAGlobalSettingsCapabilitiesUnique

Object ID

1.3.6.1.4.1.674.10892.1.1500.10.1.4

Description

Defines the set of global capabilities that all local response
agents may or may not allow to be set or reset.

Syntax

DellLocalResponseAgentCapabilitiesUnique (See Table 18-1)

Access

Read-only

LRA Global Thermal Shutdown Capabilities Unique
Name

lRAGlobalThermalShutdownCapabilitiesUnique

Object ID

1.3.6.1.4.1.674.10892.1.1500.10.1.5

Description

Defines the set of thermal shutdown capabilities that are
supported by the LRA.

Syntax

DellLRAThermalShutdownCapabilitiesUnique

Access

Read-only

LRA Global Thermal Shutdown State Settings Unique
Name

lRAGlobalThermalShutdownStateSettingsUnique

Object ID

1.3.6.1.4.1.674.10892.1.1500.10.1.6

Description

Defines the set of thermal shutdown state and settings that the
local response agent supports.

Syntax

DellLRAThermalShutdownStateSettingsUnique

Access

Read-write

Local Response Agent Group

433

LRA Action Table
The DellLocalResponseAgentCapabilitiesUnique variable in the
global action table defines the capabilities that are allowed for a particular
system. The LRA Action Table that follows selects which of the system’s
capabilities (global actions) are to be enabled.
Name

lRAActionTableTable

Object ID

1.3.6.1.4.1.674.10892.1.1500.20

Description

Defines the LRA Action Table.

Syntax

SEQUENCE OF LRAActionTableTableEntry

Access

Not accessible

LRA Action Table Entry
Name

lRAActionTableTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.1500.20.1

Description

Defines the LRA Action Table entry.

Syntax

LRAActionTableTableEntry

Access

Not accessible

Index

lRAActionTablechassisIndex,
lRAActionTableActionNumberIndex

LRA Action Table Chassis Index
Name

lRAActionTablechassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.1500.20.1.1

Description

Defines the index (one-based) of this chassis.

Syntax

DellObjectRange

Access

Read-only

434

Local Response Agent Group

LRA Action Table Action Number Index
Name

lRAActionTableActionNumberIndex

Object ID

1.3.6.1.4.1.674.10892.1.1500.20.1.2

Description

Defines the LRA action number index. The action number indexes
are as follows:
• 160 — temperature failure action definition
• 168 — cooling device failure action definition
• 172 — voltage failure action definition
• 200 — temperature warning action definition
• 202 — voltage warning action definition
• 204 — cooling device warning action definition
• 206 — amperage failure action definition
• 208 — amperage warning action definition
• 210 — a power or cooling unit redundancy lost action definition
• 212 — a power or cooling unit redundancy degraded action definition
• 214 — power supply failed action definition
• 220 — chassis intrusion action definition
• 228 — memory device warning action definition
• 474 — memory device failure action definition
• 1006 — automatic system recovery (ASR) action definition
• 1353 — power supply warning action definition
• 1553 — log near full action definition
• 1554 — log full action definition
• 1603 — processor warning action definition
• 1604 — processor failure action definition
• 1703 — battery warning action definition
• 1704 — battery failure action definition

Syntax

DellUnsigned16BitRange

Access

Read-only

Local Response Agent Group

435

LRA Action Table User Application Name
Name

lRAActionTableUserApplicationName

Object ID

1.3.6.1.4.1.674.10892.1.1500.20.1.3

Description

When the execute application value is set, provides the following
user-assignable LRA information:
• Name of the user application executable path
• File name to execute

Syntax

DisplayString (SIZE (0..256)

Access

Read-write

LRA Action Table Settings Unique
Name

lRAActionTableSettingsUnique

Object ID

1.3.6.1.4.1.674.10892.1.1500.20.1.4

Description

Defines the LRA settings.

Syntax

DellLocalResponseAgentSettingsUnique (See Table 18-3)

Access

Read-write

Local Response Agent Variable Values
This section includes definitions for server administrator-specific variable
values used in this section.
Table 18-1. LRA Capabilities Definitions
Variable Name: DellLocalResponseAgentCapabilitiesUnique
Data Type: Integer
Possible Data Values

Meaning of Data Value

speakerControlCapable(1)

The LRA can issue a speaker beep.

consoleAlertCapable(2)

The LRA can alert the console.

broadcastMessageCapable(4)

The LRA can broadcast a message.

osShutDownCapable(8)

The LRA can shut down the operating
system.

436

Local Response Agent Group

Table 18-1.

LRA Capabilities Definitions (continued)

Variable Name: DellLocalResponseAgentCapabilitiesUnique
Data Type: Integer
Possible Data Values

Meaning of Data Value

rebootCapable(16)

The LRA can reboot the system.

powerCycleCapable(32)

The LRA is capable of a system power
cycle.

powerOFFCapable(64)

The LRA can shut the system power off.

executeApplicationCapable(256) The LRA can execute a user mode
application.
lraFullyCapable(383)

Table 18-2.

The LRA has all of the preceding
capabilities.

LRA Thermal Shutdown Capabilities Unique

Variable Name: DellLRAThermalShutdownCapabilitiesUnique
Data Type: Integer
Possible Data Values

Meaning of Data Value

none(0)

The LRA has no thermal shutdown
capabilities.

Unknown capabilities(1)

The LRA’s thermal shutdown capabilities are
unknown.

enableCapable(2)

The LRA can be disabled (offline, a binary
0 value) or enabled (online, a binary 1 value).

warningCapable(4)

The LRA can carry out chassis-determined
action(s) when a warning condition is
detected.

enableOnWarningCapable(6) The LRA enables activation of chassisdetermined action(s) when a warning
condition is detected.
failureCapable(8)

The LRA can carry out chassis-determined
action(s) when a failure condition is detected.

Local Response Agent Group

437

Table 18-2. LRA Thermal Shutdown Capabilities Unique (continued)
Variable Name: DellLRAThermalShutdownCapabilitiesUnique
Data Type: Integer
Possible Data Values

Meaning of Data Value

enableOnFailureCapable(10) The LRA enables activation of chassisdetermined action(s) when a failure condition
is detected.
The LRA enables activation of chassisdetermined action(s) when either a failure or a
warning condition is detected.

enableOnWarningOrFailure
Capable(14)

Table 18-3. Local Response Agent Settings Unique
Variable Name: DellLocalResponseAgentSettingsUnique
Data Type: Integer
Possible Data Values

Meaning of Data Value

speakerControl(1)

LRA is set to issue a speaker beep.

consoleAlert(2)

LRA is set to issue a console alert.

broadcastMessage(4)

LRA is set to issue a broadcast message.

osShutDown(8)

LRA is set to issue an operating system shutdown.

reboot(16)

LRA is set to issue a system reboot.

powerCycle(32)

LRA is set to issue a system power cycle.

powerOFF(64)

LRA is set to issue a system power off.

executeApplication(256)

LRA is set to start a user mode application.

allLRASettingsUnique(383) LRA is set to all LRA settings combinations.

438

Local Response Agent Group

Cost of Ownership Group

19

The Cost of Ownership (COO) Group provides a full set of cost-tracking
objects, including fields for the computer’s manufacturer, insurer, lessor,
warranty, user, trouble tickets, and many others. You can use these management
information base (MIB) objects to obtain accurate and complete
measurements of the cost of each computer asset in your organization.

Cost of Ownership Group Tables
The Cost of Ownership Group defines objects in the following MIB tables:
•

"Cost of Ownership Table" on page 439

•

"COO Service Contract Table" on page 450

•

"COO Cost Event Log Table" on page 452

•

"COO Warranty Table" on page 454

•

"COO Lease Information Table" on page 456

•

"COO Schedule Number Table" on page 459

•

"COO Options Table" on page 460

•

"COO Maintenance Table" on page 462

•

"COO Repair Table" on page 464

•

"COO Support Information Table" on page 466

•

"COO Trouble Ticket Table" on page 468

Cost of Ownership Table
The following MIB object sets up the Cost of Ownership Table.
Name

cooTable

Object ID

1.3.6.1.4.1.674.10892.1.1600.10

Description

Defines the Cost of Ownership Table.

Syntax

SEQUENCE OF CooTableEntry

Access

Not accessible

Cost of Ownership Group

439

Cost of Ownership Table Entry
Name

cooTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.1600.10.1

Description

Defines the Cost of Ownership Table entry.

Syntax

CooTableEntry

Access

Not accessible

Index

coochassisIndex

COO Chassis Index
Name

coochassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.1600.10.1.1

Description

Defines the index (one-based) of this chassis.

Syntax

CooTableEntry

Access

Read-only

COO State
Name

cooState

Object ID

1.3.6.1.4.1.674.10892.1.1600.10.1.2

Description

Defines the acquisition state of the system.

Syntax

DellStateSettings

Access

Read-only

COO Acquisition Purchase Cost
Name

cooAquisitionPurchaseCost

Object ID

1.3.6.1.4.1.674.10892.1.1600.10.1.3

Description

Defines the purchase cost of the system.

Syntax

DellUnsigned32BitRange

Access

Read-write

440

Cost of Ownership Group

COO Acquisition Waybill Number
Name

cooAquisitionWayBillNumber

Object ID

1.3.6.1.4.1.674.10892.1.1600.10.1.4

Description

Defines the waybill number of the system.

Syntax

DellUnsigned32BitRange

Access

Read-write

COO Acquisition Install Date Name
Name

cooAquisitionInstallDateName

Object ID

1.3.6.1.4.1.674.10892.1.1600.10.1.5

Description

Defines the installation date and time for the system.

Syntax

DellDateName

Access

Read-write

COO Acquisition Purchase Order
Name

cooAquisitionPurchaseOrder

Object ID

1.3.6.1.4.1.674.10892.1.1600.10.1.6

Description

Defines the purchase order number of the system.

Syntax

DellUnsigned32BitRange

Access

Read-write

COO Acquisition Purchase Date Name
Name

cooAquisitionPurchaseDateName

Object ID

1.3.6.1.4.1.674.10892.1.1600.10.1.7

Description

Defines the purchase date and time of the system.

Syntax

DellDateName

Access

Read-write

Cost of Ownership Group

441

COO Acquisition Signing Authority Name
Name

cooAquisitionSigningAuthorityName

Object ID

1.3.6.1.4.1.674.10892.1.1600.10.1.8

Description

Defines the name of the authorized person who signs for the
system.

Syntax

DellCostofOwnershipString

Access

Read-write

COO Original Machine Configuration Expensed
Name

cooOriginalMachineConfigurationExpensed

Object ID

1.3.6.1.4.1.674.10892.1.1600.10.1.9

Description

Specifies whether the purchase of this system was expensed.

Syntax

DellBoolean

Access

Read-write

COO Original Machine Configuration Vendor Name
Name

cooOriginalMachineConfigurationVendorName

Object ID

1.3.6.1.4.1.674.10892.1.1600.10.1.10

Description

Defines the vendor name of the system.

Syntax

DellCostofOwnershipString

Access

Read-only

COO Cost Center Information Vendor Name
Name

cooCostCenterInformationVendorName

Object ID

1.3.6.1.4.1.674.10892.1.1600.10.1.11

Description

Defines the cost center name of the system.

Syntax

DellCostofOwnershipString

Access

Read-write

442

Cost of Ownership Group

COO User Information User Name
Name

cooUserInformationUserName

Object ID

1.3.6.1.4.1.674.10892.1.1600.10.1.12

Description

Defines the name of the user for this system.

Syntax

DellCostofOwnershipString

Access

Read-write

COO Extended Warranty Start Date Name
Name

cooExtendedWarrantyStartDateName

Object ID

1.3.6.1.4.1.674.10892.1.1600.10.1.13

Description

Defines the extended warranty start date for this system.

Syntax

DellDateName

Access

Read-write

COO Extended Warranty End Date Name
Name

cooExtendedWarrantyEndDateName

Object ID

1.3.6.1.4.1.674.10892.1.1600.10.1.14

Description

Defines the extended warranty end date for this system.

Syntax

DellDateName

Access

Read-write

COO Extended Warranty Cost
Name

cooExtendedWarrantyCost

Object ID

1.3.6.1.4.1.674.10892.1.1600.10.1.15

Description

Defines the extended warranty cost date for this system.

Syntax

DellUnsigned32BitRange

Access

Read-write

Cost of Ownership Group

443

COO Extended Warranty Provider Name
Name

cooExtendedWarrantyProviderName

Object ID

1.3.6.1.4.1.674.10892.1.1600.10.1.16

Description

Defines the name of the extended warranty provider for this
system.

Syntax

DellCostofOwnershipString

Access

Read-write

COO Ownership Code
Name

cooOwnershipCode

Object ID

1.3.6.1.4.1.674.10892.1.1600.10.1.17

Description

Defines the ownership code for this system.

Syntax

DellCooOwnershipCodes (See Table 19-1)

Access

Read-write

COO Corporate Owner Name
Name

cooCorporateOwnerName

Object ID

1.3.6.1.4.1.674.10892.1.1600.10.1.18

Description

Defines the name of the corporation that owns this system.

Syntax

DellCostofOwnershipString

Access

Read-write

COO Hazardous Waste Code Name
Name

cooHazardousWasteCodeName

Object ID

1.3.6.1.4.1.674.10892.1.1600.10.1.19

Description

Defines the hazardous waste code for this system.

Syntax

DellCostofOwnershipString

Access

Read-write

444

Cost of Ownership Group

COO Deployment Date Length
Name

cooDeploymentDateLength

Object ID

1.3.6.1.4.1.674.10892.1.1600.10.1.20

Description

Defines the deployment time for this system.

Syntax

DellUnsigned32BitRange

Access

Read-write

COO Deployment Duration Type
Name

cooDeploymentDurationType

Object ID

1.3.6.1.4.1.674.10892.1.1600.10.1.21

Description

Defines the deployment time units for this system.

Syntax

DellCooHourDayDurationType (See Table 19-2)

Access

Read-write

COO Training Name
Name

cooTrainingName

Object ID

1.3.6.1.4.1.674.10892.1.1600.10.1.22

Description

Defines the training that the user has for this system.

Syntax

DellCostofOwnershipString

Access

Read-write

COO Outsourcing Problem Description Name
Name

cooOutsourcingProblemDescriptionName

Object ID

1.3.6.1.4.1.674.10892.1.1600.10.1.23

Description

Defines a problem encountered with the outsourcing service
provider.

Syntax

DellCostofOwnershipString

Access

Read-write

Cost of Ownership Group

445

COO Outsourcing Service Fee Name
Name

cooOutsourcingServiceFeeName

Object ID

1.3.6.1.4.1.674.10892.1.1600.10.1.24

Description

Defines amount that the outsourcing vendor charges for service.

Syntax

DellCostofOwnershipString

Access

Read-write

COO Outsourcing Signing Authority Name
Name

cooOutsourcingSigningAuthorityName

Object ID

1.3.6.1.4.1.674.10892.1.1600.10.1.25

Description

Defines the name of the person who can sign the authorization for
service.

Syntax

DellCostofOwnershipString

Access

Read-write

COO Outsourcing Provider Fee Name
Name

cooOutsourcingProviderFeeName

Object ID

1.3.6.1.4.1.674.10892.1.1600.10.1.26

Description

Defines any additional outsourcing charge for service.

Syntax

DellCostofOwnershipString

Access

Read-write

COO Outsourcing Provider Service Level Name
Name

cooOutsourcingProviderServiceLevelName

Object ID

1.3.6.1.4.1.674.10892.1.1600.10.1.27

Description

Defines the service level agreement for the system.

Syntax

DellCostofOwnershipString

Access

Read-write

446

Cost of Ownership Group

COO Insurance Company Name
Name

cooInsuranceCompanyName

Object ID

1.3.6.1.4.1.674.10892.1.1600.10.1.28

Description

Defines the name of the company that insures this system.

Syntax

DellCostofOwnershipString

Access

Read-write

COO Box Asset Tag Name
Name

cooBoxAssetTagName

Object ID

1.3.6.1.4.1.674.10892.1.1600.10.1.29

Description

Defines the name of the asset tag.

Syntax

DellCostofOwnershipString

Access

Read-write

COO Box System Name
Name

cooBoxSystemName

Object ID

1.3.6.1.4.1.674.10892.1.1600.10.1.30

Description

Defines the name of the system.

Syntax

DellCostofOwnershipString

Access

Read-write

COO Box Central Processing Unit (CPU) Serial Number Name
Name

cooBoxCPUSerialNumberName

Object ID

1.3.6.1.4.1.674.10892.1.1600.10.1.31

Description

Defines the name of the CPU serial number for the system.

Syntax

DellCostofOwnershipString

Access

Read-write

Cost of Ownership Group

447

COO Operating System Upgrade Type Name
Name

cooOperatingSystemUpgradeTypeName

Object ID

1.3.6.1.4.1.674.10892.1.1600.10.1.32

Description

Defines the name of the operating system on this system.

Syntax

DellCostofOwnershipString

Access

Read-write

COO Operating System Upgrade Patch Level Name
Name

cooOperatingSystemUpgradePatchLevelName

Object ID

1.3.6.1.4.1.674.10892.1.1600.10.1.33

Description

Defines the name of the operating system patch level for this
system.

Syntax

DellCostofOwnershipString

Access

Read-write

COO Operating System Upgrade Date
Name

cooOperatingSystemUpgradeDate

Object ID

1.3.6.1.4.1.674.10892.1.1600.10.1.34

Description

Defines the upgrade file date for this operating system.

Syntax

DellCostofOwnershipString

Access

Read-write

COO Depreciation Duration
Name

cooDepreciationDuration

Object ID

1.3.6.1.4.1.674.10892.1.1600.10.1.35

Description

Defines the length of depreciation for this system.

Syntax

DellUnsigned32BitRange

Access

Read-write

448

Cost of Ownership Group

COO Depreciation Duration Type
Name

cooDepreciationDurationType

Object ID

1.3.6.1.4.1.674.10892.1.1600.10.1.36

Description

Defines the unit of time for the depreciation of this system.

Syntax

DellCooMonthYearDurationType

Access

Read-write

COO Depreciation Percentage
Name

cooDepreciationPercentage

Object ID

1.3.6.1.4.1.674.10892.1.1600.10.1.37

Description

Defines the percentage of depreciation for this system.

Syntax

DellUnsigned32BitRange

Access

Read-write

COO Depreciation Method Name
Name

cooDepreciationMethodName

Object ID

1.3.6.1.4.1.674.10892.1.1600.10.1.38

Description

Defines the name of the depreciation method for this system.

Syntax

DellCostofOwnershipString

Access

Read-write

COO Registration Is Registered
Name

cooRegistrationIsRegistered

Object ID

1.3.6.1.4.1.674.10892.1.1600.10.1.39

Description

Specifies whether this system is registered or not.

Syntax

DellBoolean

Access

Read-write

Cost of Ownership Group

449

COO Service Contract Table
The service contract table provides MIB objects that help you track the name,
vendor, and type of service contract you have for your system.
Name

cooServiceContractTable

Object ID

1.3.6.1.4.1.674.10892.1.1600.20

Description

Defines the COO Service Contract Table.

Syntax

SEQUENCE OF CooServiceContractTableEntry

Access

Not accessible

COO Service Contract Table Entry
Name

cooServiceContractTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.1600.20.1

Description

Defines the COO Service Contract Table entry.

Syntax

CooServiceContractTableEntry

Access

Not accessible

Index

cooServiceContractchassisIndex, cooServiceContractIndex

COO Service Contract Chassis Index
Name

cooServiceContractchassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.1600.20.1.1

Description

Defines the index (one-based) of this chassis.

Syntax

DellObjectRange

Access

Read-only

COO Service Contract Index
Name

cooServiceContractIndex

Object ID

1.3.6.1.4.1.674.10892.1.1600.20.1.2

Description

Defines the index (one-based) of this service contract.

Syntax

DellObjectRange

Access

Read-only

450

Cost of Ownership Group

COO Service Contract State
Name

cooServiceContractState

Object ID

1.3.6.1.4.1.674.10892.1.1600.20.1.3

Description

Defines the status of the service contract for this system.

Syntax

DellStateSettings

Access

Read-only

COO Service Contract Was Renewed
Name

cooServiceContractWasRenewed

Object ID

1.3.6.1.4.1.674.10892.1.1600.20.1.4

Description

Specifies whether the service contract for this system was
renewed.

Syntax

DellBoolean

Access

Read-write

COO Service Contract Type Name
Name

cooServiceContractTypeName

Object ID

1.3.6.1.4.1.674.10892.1.1600.20.1.5

Description

Defines the name of the service contract type for this system.

Syntax

DellCostofOwnershipString

Access

Read-write

COO Service Contract Vendor Name
Name

cooServiceContractVendorName

Object ID

1.3.6.1.4.1.674.10892.1.1600.20.1.6

Description

Defines the name of the service contract provider for this
system.

Syntax

DellCostofOwnershipString

Access

Read-write

Cost of Ownership Group

451

COO Cost Event Log Table
The COO Cost Event Log Table provides MIB objects that allow you to track
the duration and type of events that are logged for a particular system.
Name

cooCostEventLogTable

Object ID

1.3.6.1.4.1.674.10892.1.1600.30

Description

Defines the COO Cost Event Log Table.

Syntax

SEQUENCE OF COO CostEventLogTableEntry

Access

Not accessible

COO Cost Event Log Table Entry
Name

cooCostEventLogTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.1600.30.1

Description

Defines the COO Cost Event Log Table entry.

Syntax

cooCostEventLogTableEntry

Access

Not accessible

Index

cooCostEventLogchassisIndex, cooCostEventLogIndex

COO Cost Event Log Chassis Index
Name

cooCostEventLogchassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.1600.30.1.1

Description

Defines the index (one-based) of this chassis.

Syntax

DellObjectRange

Access

Read-only

COO Cost Event Log Index
Name

cooCostEventLogIndex

Object ID

1.3.6.1.4.1.674.10892.1.1600.30.1.2

Description

Defines the index (one-based) of the cost event log.

Syntax

DellObjectRange

Access

Read-only

452

Cost of Ownership Group

COO Cost Event Log State
Name

cooCostEventLogState

Object ID

1.3.6.1.4.1.674.10892.1.1600.30.1.3

Description

Defines the cost event log state of this system.

Syntax

DellStateSettings

Access

Read-only

COO Cost Event Log Duration
Name

cooCostEventLogDuration

Object ID

1.3.6.1.4.1.674.10892.1.1600.30.1.4

Description

Defines the duration of the event for this system.

Syntax

DellUnsigned32BitRange

Access

Read-write

COO Cost Event Log Duration Type
Name

cooCostEventLogDurationType

Object ID

1.3.6.1.4.1.674.10892.1.1600.30.1.5

Description

Defines the duration type of the event for this system.

Syntax

DellCOOHourDayDurationType (See Table 19-2)

Access

Read-write

COO Cost Event Log Description Name
Name

cooCostEventLogDescriptionName

Object ID

1.3.6.1.4.1.674.10892.1.1600.30.1.6

Description

Defines the name of the event description.

Syntax

DellCostofOwnershipString

Access

Read-write

Cost of Ownership Group

453

COO Warranty Table
The COO Warranty Table objects enable you to track facts about the type
and duration of the warranty for a particular system.
Name

cooWarrantyTable

Object ID

1.3.6.1.4.1.674.10892.1.1600.40

Description

Defines the COO Warranty Table.

Syntax

SEQUENCE OF CooWarrantyTableEntry

Access

Not accessible

COO Warranty Table Entry
Name

cooWarrantyTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.1600.40.1

Description

Defines the COO Warranty Table entry.

Syntax

CooWarrantyTableEntry

Access

Not accessible

Index

cooWarrantychassisIndex, cooWarrantyIndex

COO Warranty Chassis Index
Name

cooWarrantychassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.1600.40.1.1

Description

Defines the index (one-based) of this chassis.

Syntax

DellObjectRange

Access

Read-write

COO Warranty Index
Name

cooWarrantyIndex

Object ID

1.3.6.1.4.1.674.10892.1.1600.40.1.2

Description

Defines the index of the warranty for this system.

Syntax

DellObjectRange

Access

Read-only

454

Cost of Ownership Group

COO Warranty State
Name

cooWarrantyState

Object ID

1.3.6.1.4.1.674.10892.1.1600.40.1.3

Description

Defines the state of the warranty for this system.

Syntax

DellStateSettings

Access

Read-only

COO Warranty Duration
Name

cooWarrantyDuration

Object ID

1.3.6.1.4.1.674.10892.1.1600.40.1.4

Description

Defines the duration of the warranty.

Syntax

DellUnsigned32BitRange

Access

Read-write

COO Warranty Duration Type
Name

cooWarrantyDurationType

Object ID

1.3.6.1.4.1.674.10892.1.1600.40.1.5

Description

Defines the warranty duration type for the system.

Syntax

DellCOODayMonthDurationType

Access

Read-write

COO Warranty End Date Name
Name

cooWarrantyEndDateName

Object ID

1.3.6.1.4.1.674.10892.1.1600.40.1.6

Description

Defines the warranty end date for this system.

Syntax

DellDateName

Access

Read-write

Cost of Ownership Group

455

COO Warranty Cost
Name

cooWarrantyCost

Object ID

1.3.6.1.4.1.674.10892.1.1600.40.1.7

Description

Defines the cost of the warranty for this system.

Syntax

DellUnsigned32BitRange

Access

Read-write

COO Lease Information Table
The COO lease information MIB objects enable you to track information
about your lessor, lease duration, and lease type for each system.
Name

cooLeaseInformationTable

Object ID

1.3.6.1.4.1.674.10892.1.1600.50

Description

Defines the COO Lease Information Table.

Syntax

SEQUENCE OF CooLeaseInformationTableEntry

Access

Not accessible

COO Lease Information Table Entry
Name

cooLeaseInformationTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.1600.50.1

Description

Defines the COO Lease Information Table entry.

Syntax

CooLeaseInformationTableEntry

Access

Not accessible

Index

cooLeaseInformationchassisIndex, cooLeaseInformationIndex

COO Lease Information Chassis Index
Name

cooLeaseInformationchassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.1600.50.1.1

Description

Defines the index (one-based) of this chassis.

Syntax

DellObjectRange

Access

Read-only

456

Cost of Ownership Group

COO Lease Information Index
Name

cooLeaseInformationIndex

Object ID

1.3.6.1.4.1.674.10892.1.1600.50.1.2

Description

Defines the index of the lease information for this system.

Syntax

DellObjectRange

Access

Read-only

COO Lease Information State
Name

cooLeaseInformationState

Object ID

1.3.6.1.4.1.674.10892.1.1600.50.1.3

Description

Defines the lease information state for this system.

Syntax

DellStateSettings

Access

Read-write

COO Lease Information Multiple Schedules
Name

cooLeaseInformationMultipleSchedules

Object ID

1.3.6.1.4.1.674.10892.1.1600.50.1.4

Description

Defines whether there are multiple schedules for this lease.

Syntax

DellBoolean

Access

Read-only

COO Lease Information Buyout Amount
Name

cooLeaseInformationBuyOutAmount

Object ID

1.3.6.1.4.1.674.10892.1.1600.50.1.5

Description

Defines the balance purchase price for this system.

Syntax

DellUnsigned32BitRange

Access

Read-write

Cost of Ownership Group

457

COO Lease Information Lease Rate Factor
Name

cooLeaseInformationLeaseRateFactor

Object ID

1.3.6.1.4.1.674.10892.1.1600.50.1.6

Description

Defines the rate factor for the lease on this system.

Syntax

DellUnsigned32BitRange

Access

Read-write

COO Lease Information End Date Name
Name

cooLeaseInformationEndDateName

Object ID

1.3.6.1.4.1.674.10892.1.1600.50.1.7

Description

Defines the end date for the lease on this system.

Syntax

DellDateName

Access

Read-write

COO Lease Information Fair Market Value
Name

cooLeaseInformationFairMarketValue

Object ID

1.3.6.1.4.1.674.10892.1.1600.50.1.8

Description

Defines the fair market value of this system.

Syntax

DellUnsigned32BitRange

Access

Read-write

COO Lease Information Lessor Name
Name

cooLeaseInformationLessorName

Object ID

1.3.6.1.4.1.674.10892.1.1600.50.1.9

Description

Defines the name of the lessor of this system.

Syntax

DellCostofOwnershipString

Access

Read-write

458

Cost of Ownership Group

COO Schedule Number Table
Name

cooScheduleNumberTable

Object ID

1.3.6.1.4.1.674.10892.1.1600.60

Description

Defines the COO Schedule Number Information Table.

Syntax

SEQUENCE OF CooScheduleNumberTableEntry

Access

Not accessible

COO Schedule Number Table Entry
Name

cooScheduleNumberTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.1600.60.1

Description

Defines the COO Schedule Number Information Table entry.

Syntax

CooScheduleNumberTableEntry

Access

Not accessible

Index

cooScheduleNumberchassisIndex, cooScheduleNumberIndex

COO Schedule Number Chassis Index
Name

cooScheduleNumberchassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.1600.60.1.1

Description

Defines the index (one-based) of this chassis.

Syntax

DellObjectRange

Access

Read-only

COO Schedule Number Index
Name

cooScheduleNumberIndex

Object ID

1.3.6.1.4.1.674.10892.1.1600.60.1.2

Description

Defines the index of the schedule number information.

Syntax

DellObjectRange

Access

Read-only

Cost of Ownership Group

459

COO Schedule Number State
Name

cooScheduleNumberState

Object ID

1.3.6.1.4.1.674.10892.1.1600.60.1.3

Description

Defines the schedule number information state of this system.

Syntax

DellStateSettings

Access

Read-only

COO Schedule Number Lease Information Index Reference
Name

cooScheduleNumberLeaseInformationIndexReference

Object ID

1.3.6.1.4.1.674.10892.1.1600.60.1.4

Description

Defines the lease information index number to reference the
schedule number.

Syntax

DellUnsigned32BitRange

Access

Read-write

COO Schedule Number Description Name
Name

cooScheduleNumberDescriptionName

Object ID

1.3.6.1.4.1.674.10892.1.1600.60.1.5

Description

Describes the schedule number information.

Syntax

DellCostofOwnershipString

Access

Read-write

COO Options Table
Name

cooOptionsTable

Object ID

1.3.6.1.4.1.674.10892.1.1600.70

Description

Defines the COO Options Table.

Syntax

SEQUENCE OF CooOptionsTableEntry

Access

Not accessible

460

Cost of Ownership Group

COO Options Table Entry
Name

cooOptionsTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.1600.70.1

Description

Defines the COO Options Table entry.

Syntax

CooOptionsTableEntry

Access

Not accessible

Index

cooOptionschassisIndex, cooOptionsIndex

COO Options Chassis Index
Name

cooOptionschassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.1600.70.1.1

Description

Defines the index (one-based) of this chassis.

Syntax

DellObjectRange

Access

Read-only

COO Options Index
Name

cooOptionsIndex

Object ID

1.3.6.1.4.1.674.10892.1.1600.70.1.2

Description

Defines the index (one-based) of the option information for this
system.

Syntax

DellObjectRange

Access

Read-only

COO Options State
Name

cooOptionsState

Object ID

1.3.6.1.4.1.674.10892.1.1600.70.1.3

Description

Defines the option information state for this system.

Syntax

DellStateSettings

Access

Read-only

Cost of Ownership Group

461

COO Options Lease Information Index Reference
Name

cooOptionsLeaseInformationIndexReference

Object ID

1.3.6.1.4.1.674.10892.1.1600.70.1.4

Description

Defines the lease information index of the option information for
this system.

Syntax

DellUnsigned32BitRange

Access

Read-write

COO Options Description Name
Name

cooOptionsDescriptionName

Object ID

1.3.6.1.4.1.674.10892.1.1600.70.1.5

Description

Defines the option information description name.

Syntax

DellCostofOwnershipString

Access

Read-write

COO Maintenance Table
Name

cooMaintenanceTable

Object ID

1.3.6.1.4.1.674.10892.1.1600.80

Description

Defines the COO Maintenance Table.

Syntax

SEQUENCE OF CooMaintenanceTableEntry

Access

Not accessible

COO Maintenance Table Entry
Name

cooMaintenanceTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.1600.80.1

Description

Defines the COO Maintenance Table entry.

Syntax

CooMaintenanceTableEntry

Access

Not accessible

Index

cooMaintenancechassisIndex, cooMaintenanceIndex

462

Cost of Ownership Group

COO Maintenance Chassis Index
Name

cooMaintenancechassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.1600.80.1.1

Description

Defines the index (one-based) of this chassis.

Syntax

DellObjectRange

Access

Read-only

COO Maintenance Index
Name

cooMaintenanceIndex

Object ID

1.3.6.1.4.1.674.10892.1.1600.80.1.2

Description

Defines the index of this system’s maintenance information.

Syntax

DellObjectRange

Access

Read-only

COO Maintenance State
Name

cooMaintenanceState

Object ID

1.3.6.1.4.1.674.10892.1.1600.80.1.3

Description

Defines the state of this system’s maintenance information.

Syntax

DellStateSettings

Access

Read-only

COO Maintenance Start Date Name
Name

cooMaintenanceStartDateName

Object ID

1.3.6.1.4.1.674.10892.1.1600.80.1.4

Description

Defines the start date for maintenance on this system.

Syntax

DellDateName

Access

Read-write

Cost of Ownership Group

463

COO Maintenance End Date Name
Name

cooMaintenanceEndDateName

Object ID

1.3.6.1.4.1.674.10892.1.1600.80.1.5

Description

Defines the end date for maintenance on this system.

Syntax

DellDateName

Access

Read-write

COO Maintenance Provider Name
Name

cooMaintenanceProviderName

Object ID

1.3.6.1.4.1.674.10892.1.1600.80.1.6

Description

Defines the maintenance provider’s name.

Syntax

DellStateSettings

Access

Read-write

COO Maintenance Restrictions Name
Name

cooMaintenanceRestrictionsName

Object ID

1.3.6.1.4.1.674.10892.1.1600.80.1.7

Description

Defines the maintenance agreement restrictions.

Syntax

DellCostofOwnershipString

Access

Read-write

COO Repair Table
Name

cooRepairTable

Object ID

1.3.6.1.4.1.674.10892.1.1600.90

Description

Defines the COO Repair Table.

Syntax

SEQUENCE OF CooRepairTableEntry

Access

Not accessible

464

Cost of Ownership Group

COO Repair Table Entry
Name

cooRepairTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.1600.90.1

Description

Defines the COO Repair Table entry.

Syntax

CooRepairTableEntry

Access

Not accessible

Index

cooRepairchassisIndex, cooRepairIndex

COO Repair Chassis Index
Name

cooRepairchassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.1600.90.1.1

Description

Defines the index (one-based) of this chassis.

Syntax

DellObjectRange

Access

Read-only

COO Repair Index
Name

cooRepairIndex

Object ID

1.3.6.1.4.1.674.10892.1.1600.90.1.2

Description

Defines the index (one-based) of the repair information for this
system.

Syntax

DellObjectRange

Access

Read-only

COO Repair State
Name

cooRepairState

Object ID

1.3.6.1.4.1.674.10892.1.1600.90.1.3

Description

Defines the state of the repair information for this system.

Syntax

DellStateSettings

Access

Read-only

Cost of Ownership Group

465

COO Repair Counter
Name

cooRepairCounter

Object ID

1.3.6.1.4.1.674.10892.1.1600.90.1.4

Description

Defines the number of repairs that this system has undergone.

Syntax

DellCostofOwnershipString

Access

Read-write

COO Repair Vendor Name
Name

cooRepairVendorName

Object ID

1.3.6.1.4.1.674.10892.1.1600.90.1.5

Description

Defines the name of the vendor that repairs this system.

Syntax

DellStateSettings

Access

Read-only

COO Support Information Table
Name

cooSupportInformationTable

Object ID

1.3.6.1.4.1.674.10892.1.1600.100

Description

Defines the COO Support Information Table.

Syntax

SEQUENCE OF cooSupportInformationTableEntry

Access

Not accessible

COO Support Information Table Entry
Name

cooSupportInformationTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.1600.100.1

Description

Defines the COO Support Information Table entry.

Syntax

cooSupportInformationTableEntry

Access

Not accessible

Index

cooSupportInformationchassisIndex
cooSupportInformationIndex

466

Cost of Ownership Group

COO Support Information Chassis Index
Name

cooSupportInformationchassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.1600.100.1.1

Description

Defines the index (one-based) of this chassis.

Syntax

DellObjectRange

Access

Read-only

COO Support Information Index
Name

cooSupportInformationIndex

Object ID

1.3.6.1.4.1.674.10892.1.1600.100.1.2

Description

Defines the index (one-based) for this system’s support
information.

Syntax

DellObjectRange

Access

Read-only

COO Support Information State
Name

cooSupportInformationState

Object ID

1.3.6.1.4.1.674.10892.1.1600.100.1.3

Description

Defines the support information state for this system.

Syntax

DellStateSettings

Access

Read-only

COO Support Information Is Outsourced
Name

cooSupportInformationIsOutsourced

Object ID

1.3.6.1.4.1.674.10892.1.1600.100.1.4

Description

Specifies whether the support for this system is outsourced or not.

Syntax

DellBoolean

Access

Read-write

Cost of Ownership Group

467

COO Support Information Type
Name

cooSupportInformationType

Object ID

1.3.6.1.4.1.674.10892.1.1600.100.1.5

Description

Defines the type of component, system, or network problem that
occurred.

Syntax

DellUnsigned32BitRange

Access

Read-write

COO Support Information Help Desk Name
Name

cooSupportInformationHelpDeskName

Object ID

1.3.6.1.4.1.674.10892.1.1600.100.1.6

Description

Defines the help desk information provided.

Syntax

DellCostofOwnershipString

Access

Read-write

COO Support Information Fix Type Name
Name

cooSupportInformationFixTypeName

Object ID

1.3.6.1.4.1.674.10892.1.1600.100.1.7

Description

Defines the method used to fix the problem.

Syntax

DellCostofOwnershipString

Access

Read-write

COO Trouble Ticket Table
The MIB objects in the Trouble Ticket Table enable you to track details of
any trouble tickets that you open for your system.
Name

cooTroubleTicketTable

Object ID

1.3.6.1.4.1.674.10892.1.1600.110

Description

Defines the COO Trouble Ticket Table.

Syntax

SEQUENCE OF cooTroubleTicketTableEntry

Access

Not accessible

468

Cost of Ownership Group

COO Trouble Ticket Table Entry
Name

cooTroubleTicketTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.1600.110.1

Description

Defines the COO Trouble Ticket Table entry.

Syntax

cooTroubleTicketTableEntry

Access

Not accessible

Index

cooTroubleTicketchassisIndex, cooTroubleTicketIndex

COO Trouble Ticket Chassis Index
Name

cooTroubleTicketchassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.1600.110.1.1

Description

Defines the index (one-based) of this chassis.

Syntax

DellObjectRange

Access

Read-only

COO Trouble Ticket Index
Name

cooTroubleTicketIndex

Object ID

1.3.6.1.4.1.674.10892.1.1600.110.1.2

Description

Defines the index (one-based) of the system’s trouble ticket
information.

Syntax

DellObjectRange

Access

Read-only

COO Trouble Ticket State
Name

cooTroubleTicketState

Object ID

1.3.6.1.4.1.674.10892.1.1600.110.1.3

Description

Defines the trouble ticket information state for this system.

Syntax

DellStateSettings

Access

Read-only

Cost of Ownership Group

469

COO Trouble Ticket Support Information Index Reference
Name

cooTroubleTicketSupportInformationIndexReference

Object ID

1.3.6.1.4.1.674.10892.1.1600.110.1.4

Description

Defines the support information index that references the trouble ticket.

Syntax

DellUnsigned32BitRange

Access

Read-write

COO Trouble Ticket Number Name
Name

cooTroubleTicketNumberName

Object ID

1.3.6.1.4.1.674.10892.1.1600.110.1.5

Description

Defines the trouble ticket number for this system.

Syntax

DellCostofOwnershipString

Access

Read-write

Cost of Ownership Variable Values
This section includes definitions for server administrator-specific variable
values used in this section.
Table 19-1. COO Ownership Codes
Variable Name: DellCooOwnershipCodes
Data Type: Integer
Possible Data Values

Meaning of Data Value

other(1)

The ownership code is not one of following:

unknown(2)

The ownership code is unknown.

owned(3)

The ownership code is owned.

leased(4)

The ownership code is leased.

rented(5)

The ownership code is rented.

offOfLease(6)

The ownership code is off of lease.

transfer(7)

The ownership code is transfer.

470

Cost of Ownership Group

Table 19-2.

COO Hour Day Duration Type

Variable Name: DellCooHourDayDurationType
Data Type: Integer
Possible Data Values

Meaning of Data Value

unknown(1)

Duration time type is unknown.

hours(2)

Duration time type is in hours.

days(3)

Duration time type is in days.

Table 19-3.

COO Day Month Duration Type

Variable Name: DellCooDayMonthDurationType
Data Type: Integer
Possible Data Values

Meaning of Data Value

unknown(1)

Duration time type is unknown.

days(3)

Duration time type is in days.

months(4)

Duration time type is in months.

Table 19-4.

COO Month Year Duration Type

Variable Name: DellCooMonthYearDurationType
Data Type: Integer
Possible Data Values

Meaning of Data Value

unknown(1)

Duration time type is unknown.

months(4)

Duration time type is in months.

years(5)

Duration time type is in years.

Cost of Ownership Group

471

472

Cost of Ownership Group

Remote Access Group

20

The Remote Access Group provides information about the remote access
hardware that may be present in your system. In addition to providing general
information about the capabilities and settings of the remote access
hardware, this group provides information about administrative users,
SNMP trap destinations, modem configuration for dial-up networking,
dial-in configuration, and dial-out destinations.

DRAC 4 and DRAC 5
On systems with Dell Remote Access Controller (DRAC) 4 or DRAC 5,
the Remote Access Group includes only the Remote Access Table.

Remote Access Table
The following MIB object sets up the Remote Access Table.
Name

remoteAccessTable

Object ID

1.3.6.1.4.1.674.10892.1.1700.10

Description

Defines the Remote Access Table.

Syntax

SEQUENCE OF RemoteAccessTableEntry

Access

Not accessible

Remote Access Table Entry
Name

remoteAccessTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.1700.10.1

Description

Defines the Remote Access Table entry.

Syntax

RemoteAccessTableEntry

Access

Not accessible

Index

remoteAccessChassisIndex, remoteAccessAdapterIndex

Remote Access Group

473

Remote Access Chassis Index
Name

remoteAccessChassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.1700.10.1.1

Description

Defines the index (one-based) of the chassis containing the
remote access hardware.

Syntax

DellObjectRange

Access

Read-only

Remote Access Adapter Index
Name

remoteAccessAdapterIndex

Object ID

1.3.6.1.4.1.674.10892.1.1700.10.1.2

Description

Defines the index (one-based) of the remote access hardware.

Syntax

DellObjectRange

Access

Read-only

Remote Access Type
Name

remoteAccessType

Object ID

1.3.6.1.4.1.674.10892.1.1700.10.1.3

Description

Defines the type of remote access hardware.

Syntax

DellRemoteAccessType (See Table 20-1)

Access

Read-only

Remote Access State Capabilities
Name

remoteAccessStateCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.1700.10.1.4

Description

Defines the state capabilities of the remote access hardware.

Syntax

DellStateCapabilities

Access

Read-only

474

Remote Access Group

Remote Access State Settings
Name

remoteAccessStateSettings

Object ID

1.3.6.1.4.1.674.10892.1.1700.10.1.5

Description

Defines the state setting of the remote access hardware.

Syntax

DellStateSettings

Access

Read-write

Remote Access Status
Name

remoteAccessStatus

Object ID

1.3.6.1.4.1.674.10892.1.1700.10.1.6

Description

Defines the status of the remote access hardware.

Syntax

DellStatus

Access

Read-only

Remote Access Product Info Name
Name

remoteAccessProductInfoName

Object ID

1.3.6.1.4.1.674.10892.1.1700.10.1.7

Description

Defines the name of the product providing the remote access
functionality.

Syntax

DellDisplayString (SIZE (0..63))

Access

Read-only

Remote Access Description Info Name
Name

remoteAccessDescriptionInfoName

Object ID

1.3.6.1.4.1.674.10892.1.1700.10.1.8

Description

Defines the description of the product providing the remote
access functionality.

Syntax

DellDisplayString (SIZE (0..255))

Access

Read-only

Remote Access Group

475

Remote Access Version Info Name
Name

remoteAccessVersionInfoName

Object ID

1.3.6.1.4.1.674.10892.1.1700.10.1.9

Description

Defines the version of the product providing the remote access
functionality.

Syntax

DellDisplayString (SIZE (0..63))

Access

Read-only

Remote Access Local Area Network (LAN) Capabilities
Name

remoteAccessLANCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.1700.10.1.14

Description

Defines the LAN capabilities of the remote access hardware.

Syntax

DellRemoteAccessLANCapabilities (See Table 20-6)

Access

Read-only

Remote Access LAN Settings
Name

remoteAccessLANSettings

Object ID

1.3.6.1.4.1.674.10892.1.1700.10.1.15

Description

Defines the LAN settings of the remote access hardware.

Syntax

DellRemoteAccessLANSettings (See Table 20-7)

Access

Read-write

Remote Access Network Interface Controller (NIC) Static IP Address
Name

remoteAccessNICStaticIPAddress

Object ID

1.3.6.1.4.1.674.10892.1.1700.10.1.25

Description

Defines the static IP address to be used by the integrated NIC
provided by the remote access hardware.

Syntax

IpAddress

Access

Read-write

476

Remote Access Group

Remote Access NIC Static Netmask Address
Name

remoteAccessNICStaticNetmaskAddress

Object ID

1.3.6.1.4.1.674.10892.1.1700.10.1.26

Description

Defines the netmask for the static IP address to be used by the
integrated NIC provided by the remote access hardware.

Syntax

IpAddress

Access

Read-write

Remote Access NIC Static Gateway Address
Name

remoteAccessNICStaticGatewayAddress

Object ID

1.3.6.1.4.1.674.10892.1.1700.10.1.27

Description

Defines the IP address for the gateway associated with the static
IP address to be used by the integrated NIC provided by the
remote access hardware.

Syntax

IpAddress

Access

Read-write

Remote Access Personal Computer Memory Card International Association
(PCMCIA) Info Name
Name

remoteAccessPCMCIAInfoName

Object ID

1.3.6.1.4.1.674.10892.1.1700.10.1.28

Description

Defines the information for the PCMCIA device used by the
remote access hardware.

Syntax

DisplayString (SIZE (0..63))

Access

Read-only

Remote Access Group

477

Remote Access Miscellaneous Information Name
Name

remoteAccessMiscInfoName

Object ID

1.3.6.1.4.1.674.10892.1.1700.10.1.29

Description

Defines the miscellaneous information for the remote access hardware.

Syntax

DisplayString (SIZE (0..63))

Access

Read-write

Remote Access NIC Current IP Address
Name

remoteAccessNICCurrentIPAddress

Object ID

1.3.6.1.4.1.674.10892.1.1700.10.1.30

Description

Defines the IP address currently being used by the integrated
NIC provided by the remote access hardware.

Syntax

IpAddress

Access

Read-only

Remote Access NIC Current Netmask Address
Name

remoteAccessNICCurrentNetmaskAddress

Object ID

1.3.6.1.4.1.674.10892.1.1700.10.1.31

Description

Defines the netmask currently being used by the integrated NIC
provided by the remote access hardware.

Syntax

IpAddress

Access

Read-only

Remote Access NIC Current Gateway Address
Name

remoteAccessNICCurrentGatewayAddress

Object ID

1.3.6.1.4.1.674.10892.1.1700.10.1.32

Description

Defines the IP address for the gateway currently being used by
the integrated NIC provided by the remote access hardware.

Syntax

IpAddress

Access

Read-only

478

Remote Access Group

Remote Access NIC Current Information From Dynamic Host Configuration Protocol
(DHCP)
Name

remoteAccessNICCurrentInfoFromDHCP

Object ID

1.3.6.1.4.1.674.10892.1.1700.10.1.33

Description

Defines whether DHCP was used to obtain the NIC
information currently being used by the integrated NIC
provided by the remote access hardware.

Syntax

DellBoolean

Access

Read-only

Remote Access Remote Connect URL
Name

remoteAccessRemoteConnectURL

Object ID

1.3.6.1.4.1.674.10892.1.1700.10.1.34

Description

Defines the URL for launching the Remote Access Remote
Connect Interface.

Syntax

DisplayString (SIZE (0..63))

Access

Mandatory

DRAC III
On systems with DRAC III, the Remote Access Group includes the following
MIB tables:
•

"Remote Access Table" on page 480

•

"Remote User Administration Table" on page 489

•

"Remote SNMP Trap Table" on page 497

•

"Remote Dial-Up Table" on page 502

•

"Remote User Dial-In Configuration Table" on page 506

•

"Remote Dial-Out Table" on page 509

Remote Access Group

479

Remote Access Table
The following MIB object sets up the Remote Access Table.
Name

remoteAccessTable

Object ID

1.3.6.1.4.1.674.10892.1.1700.10

Description

Defines the Remote Access Table.

Syntax

SEQUENCE OF RemoteAccessTableEntry

Access

Not accessible

Remote Access Table Entry
Name

remoteAccessTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.1700.10.1

Description

Defines the Remote Access Table entry.

Syntax

RemoteAccessTableEntry

Access

Not accessible

Index

remoteAccessChassisIndex, remoteAccessAdapterIndex

Remote Access Chassis Index
Name

remoteAccessChassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.1700.10.1.1

Description

Defines the index (one-based) of the chassis containing the
remote access hardware.

Syntax

DellObjectRange

Access

Read-only

Remote Access Adapter Index
Name

remoteAccessAdapterIndex

Object ID

1.3.6.1.4.1.674.10892.1.1700.10.1.2

Description

Defines the index (one-based) of the remote access hardware.

Syntax

DellObjectRange

Access

Read-only

480

Remote Access Group

Remote Access Type
Name

remoteAccessType

Object ID

1.3.6.1.4.1.674.10892.1.1700.10.1.3

Description

Defines the type of remote access hardware.

Syntax

DellRemoteAccessType (See Table 20-1)

Access

Read-only

Remote Access State Capabilities
Name

remoteAccessStateCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.1700.10.1.4

Description

Defines the state capabilities of the remote access hardware.

Syntax

DellStateCapabilities

Access

Read-only

Remote Access State Settings
Name

remoteAccessStateSettings

Object ID

1.3.6.1.4.1.674.10892.1.1700.10.1.5

Description

Defines the state setting of the remote access hardware.

Syntax

DellStateSettings

Access

Read-write

Remote Access Status
Name

remoteAccessStatus

Object ID

1.3.6.1.4.1.674.10892.1.1700.10.1.6

Description

Defines the status of the remote access hardware.

Syntax

DellStatus

Access

Read-only

Remote Access Group

481

Remote Access Product Info Name
Name

remoteAccessProductInfoName

Object ID

1.3.6.1.4.1.674.10892.1.1700.10.1.7

Description

Defines the name of the product providing the remote access
functionality.

Syntax

DellDisplayString (SIZE (0..63))

Access

Read-only

Remote Access Description Info Name
Name

remoteAccessDescriptionInfoName

Object ID

1.3.6.1.4.1.674.10892.1.1700.10.1.8

Description

Defines the description of the product providing the remote access
functionality.

Syntax

DellDisplayString (SIZE (0..255))

Access

Read-only

Remote Access Version Info Name
Name

remoteAccessVersionInfoName

Object ID

1.3.6.1.4.1.674.10892.1.1700.10.1.9

Description

Defines the version of the product providing the remote access
functionality.

Syntax

DellDisplayString (SIZE (0..63))

Access

Read-only

Remote Access Control Capabilities
Name

remoteAccessControlCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.1700.10.1.10

Description

Defines the control capabilities of the remote access hardware.

Syntax

DellRemoteAccessControlCapabilities (See Table 20-2)

Access

Read-only

482

Remote Access Group

Remote Access Control Settings
Name

remoteAccessControlSettings

Object ID

1.3.6.1.4.1.674.10892.1.1700.10.1.11

Description

Defines the control settings of the remote access hardware.

Syntax

DellRemoteAccessControlSettings (See Table 20-3)

Access

Read-write

Remote Access Monitor Capabilities
Name

remoteAccessMonitorCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.1700.10.1.12

Description

Defines the monitor capabilities of the remote access hardware.

Syntax

DellRemoteAccessMonitorCapabilities (See Table 20-4)

Access

Read-only

Remote Access Monitor Settings
Name

remoteAccessMonitorSettings

Object ID

1.3.6.1.4.1.674.10892.1.1700.10.1.13

Description

Defines the monitor settings of the remote access hardware.

Syntax

DellRemoteAccessMonitorSettings (See Table 20-5)

Access

Read-write

Remote Access Local Area Network (LAN) Capabilities
Name

remoteAccessLANCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.1700.10.1.14

Description

Defines the LAN capabilities of the remote access hardware.

Syntax

DellRemoteAccessLANCapabilities (See Table 20-6)

Access

Read-only

Remote Access Group

483

Remote Access LAN Settings
Name

remoteAccessLANSettings

Object ID

1.3.6.1.4.1.674.10892.1.1700.10.1.15

Description

Defines the LAN settings of the remote access hardware.

Syntax

DellRemoteAccessLANSettings (See Table 20-7)

Access

Read-write

Remote Access Host Capabilities
Name

remoteAccessHostCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.1700.10.1.16

Description

Defines the host capabilities of the remote access hardware.

Syntax

DellRemoteAccessHostCapabilities (See Table 20-8)

Access

Read-only

Remote Access Host Settings
Name

remoteAccessHostSettings

Object ID

1.3.6.1.4.1.674.10892.1.1700.10.1.17

Description

Defines the host settings of the remote access hardware.

Syntax

DellRemoteAccessHostSettings (See Table 20-9)

Access

Read-write

Remote Access Out-of-Band Simple Network Management Protocol (SNMP)
Capabilities
Name

remoteAccessOutOfBandSNMPCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.1700.10.1.18

Description

Defines the out-of-band SNMP capabilities of the remote access
hardware.

Syntax

DellRemoteAccessOutOfBandSNMPCapabilities (See
Table 20-10)

Access

Read-only

484

Remote Access Group

Remote Access Out-of-Band SNMP Settings
Name

remoteAccessOutOfBandSNMPSettings

Object ID

1.3.6.1.4.1.674.10892.1.1700.10.1.19

Description

Defines the out-of-band SNMP settings of the remote access hardware.

Syntax

DellRemoteAccessOutOfBandSNMPSettings (See Table 20-11)

Access

Read-write

Remote Access Simple Mail Transfer Protocol (SMTP) Server Internet Protocol (IP)
Address
Name

remoteAccessSMTPServerIPAddress

Object ID

1.3.6.1.4.1.674.10892.1.1700.10.1.20

Description

Defines the IP address for the SMTP server used by the remote
access hardware.

Syntax

IpAddress

Access

Read-write

Remote Access Floppy Trivial File Transfer Protocol (TFTP) IP Address
Name

remoteAccessFloppyTFTPIPAddress

Object ID

1.3.6.1.4.1.674.10892.1.1700.10.1.21

Description

Defines the IP address of the TFTP server providing the
operating system image used by the remote access hardware.

Syntax

IpAddress

Access

Read-write

Remote Access Floppy TFTP Path Name
Name

remoteAccessFloppyTFTPPathName

Object ID

1.3.6.1.4.1.674.10892.1.1700.10.1.22

Description

Defines the file name of the operating system image obtained
from the TFTP server used by the remote access hardware.

Syntax

DisplayString (SIZE (0..255))

Access

Read-write

Remote Access Group

485

Remote Access Firmware Update IP Address
Name

remoteAccessFirmwareUpdateIPAddress

Object ID

1.3.6.1.4.1.674.10892.1.1700.10.1.23

Description

Defines the IP address of the update server providing the
firmware image used by the remote access hardware.

Syntax

IpAddress

Access

Read-write

Remote Access Firmware Update Path Name
Name

remoteAccessFirmwareUpdatePathName

Object ID

1.3.6.1.4.1.674.10892.1.1700.10.1.24

Description

Defines the file name of the firmware image obtained from the
update server used by the remote access hardware.

Syntax

DisplayString (SIZE (0..255))

Access

Read-write

Remote Access Network Interface Controller (NIC) Static IP Address
Name

remoteAccessNICStaticIPAddress

Object ID

1.3.6.1.4.1.674.10892.1.1700.10.1.25

Description

Defines the static IP address to be used by the integrated NIC
provided by the remote access hardware.

Syntax

IpAddress

Access

Read-write

Remote Access NIC Static Netmask Address
Name

remoteAccessNICStaticNetmaskAddress

Object ID

1.3.6.1.4.1.674.10892.1.1700.10.1.26

Description

Defines the netmask for the static IP address to be used by the
integrated NIC provided by the remote access hardware.

Syntax

IpAddress

Access

Read-write

486

Remote Access Group

Remote Access NIC Static Gateway Address
Name

remoteAccessNICStaticGatewayAddress

Object ID

1.3.6.1.4.1.674.10892.1.1700.10.1.27

Description

Defines the IP address for the gateway associated with the static
IP address to be used by the integrated NIC provided by the
remote access hardware.

Syntax

IpAddress

Access

Read-write

Remote Access Personal Computer Memory Card International Association (PCMCIA)
Info Name
Name

remoteAccessPCMCIAInfoName

Object ID

1.3.6.1.4.1.674.10892.1.1700.10.1.28

Description

Defines the information for the PCMCIA device used by the
remote access hardware.

Syntax

DisplayString (SIZE (0..63))

Access

Read-only

Remote Access Miscellaneous Information Name
Name

remoteAccessMiscInfoName

Object ID

1.3.6.1.4.1.674.10892.1.1700.10.1.29

Description

Defines the miscellaneous information for the remote
access hardware.

Syntax

DisplayString (SIZE (0..63))

Access

Read-write

Remote Access Group

487

Remote Access NIC Current IP Address
Name

remoteAccessNICCurrentIPAddress

Object ID

1.3.6.1.4.1.674.10892.1.1700.10.1.30

Description

Defines the IP address currently being used by the integrated
NIC provided by the remote access hardware.

Syntax

IpAddress

Access

Read-only

Remote Access NIC Current Netmask Address
Name

remoteAccessNICCurrentNetmaskAddress

Object ID

1.3.6.1.4.1.674.10892.1.1700.10.1.31

Description

Defines the netmask currently being used by the integrated NIC
provided by the remote access hardware.

Syntax

IpAddress

Access

Read-only

Remote Access NIC Current Gateway Address
Name

remoteAccessNICCurrentGatewayAddress

Object ID

1.3.6.1.4.1.674.10892.1.1700.10.1.32

Description

Defines the IP address for the gateway currently being used by
the integrated NIC provided by the remote access hardware.

Syntax

IpAddress

Access

Read-only

488

Remote Access Group

Remote Access NIC Current Information From Dynamic Host Configuration Protocol
(DHCP)
Name

remoteAccessNICCurrentInfoFromDHCP

Object ID

1.3.6.1.4.1.674.10892.1.1700.10.1.33

Description

Defines whether DHCP was used to obtain the NIC
information currently being used by the integrated NIC
provided by the remote access hardware.

Syntax

DellBoolean

Access

Read-only

Remote User Administration Table
Name

remoteUserAdminTable

Object ID

1.3.6.1.4.1.674.10892.1.1700.20

Description

Defines the Remote Access User Administration Table.

Syntax

SEQUENCE OF RemoteUserAdminTableEntry

Access

Not accessible

Remote User Admin Table Entry
Name

remoteUserAdminTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.1700.20.1

Description

Defines the Remote Access User Administration Table entry.

Syntax

RemoteUserAdminTableEntry

Access

Not accessible

Index

remoteUserAdminChassisIndex,
remoteUserAdminAdapterIndex, remoteUserAdminUserIndex

Remote Access Group

489

Remote User Admin Chassis Index
Name

remoteUserAdminChassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.1700.20.1.1

Description

Defines the index (one-based) of the chassis containing the
remote access hardware.

Syntax

DellObjectRange

Access

Read-only

Remote User Admin Adapter Index
Name

remoteUserAdminAdapterIndex

Object ID

1.3.6.1.4.1.674.10892.1.1700.20.1.2

Description

Defines the index (one-based) of the remote access hardware
used by this remote access user.

Syntax

DellObjectRange

Access

Read-only

Remote User Admin User Index
Name

remoteUserAdminUserIndex

Object ID

1.3.6.1.4.1.674.10892.1.1700.20.1.3

Description

Defines the index (one-based) of this remote access user.

Syntax

DellObjectRange

Access

Read-only

Remote User Admin State Capabilities
Name

remoteUserAdminStateCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.1700.20.1.4

Description

Defines the state capabilities for this remote access user.

Syntax

DellRemoteUserAdminStateCapabilities (See Table 20-12)

Access

Read-only

490

Remote Access Group

Remote User Admin State Settings
Name

remoteUserAdminStateSettings

Object ID

1.3.6.1.4.1.674.10892.1.1700.20.1.5

Description

Defines the state settings for this remote access user.

Syntax

DellRemoteUserAdminStateSettings (See Table 20-13)

Access

Read-write

Remote User Admin Status
Name

remoteUserAdminStatus

Object ID

1.3.6.1.4.1.674.10892.1.1700.20.1.6

Description

Defines the status for this remote access user.

Syntax

DellStatus

Access

Read-only

Remote User Admin User Name
Name

remoteUserAdminUserName

Object ID

1.3.6.1.4.1.674.10892.1.1700.20.1.7

Description

Defines the user name for this remote access user.

Syntax

DisplayString (SIZE (0..19))

Access

Read-write

Remote User Admin User Password Name
Name

remoteUserAdminUserPasswordName

Object ID

1.3.6.1.4.1.674.10892.1.1700.20.1.8

Description

Defines the password for this remote access user.

Syntax

DisplayString (SIZE (0..255))

Access

Read-write

Remote Access Group

491

Remote User Admin User Privilege
Name

remoteUserAdminUserPrivilege

Object ID

1.3.6.1.4.1.674.10892.1.1700.20.1.9

Description

Defines the privileges for this remote access user.

Syntax

DisplayString (SIZE (0..31))

Access

Read-write

Remote User Admin User Privilege Capabilities
Name

remoteUserAdminUserPrivilegeCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.1700.20.1.10

Description

Defines the privilege capabilities for this remote access user.

Syntax

DisplayString (SIZE (0..31))

Access

Read-only

Remote User Admin Alert Filter DRS Events Mask
Name

remoteUserAdminAlertFilterDrsEventsMask

Object ID

1.3.6.1.4.1.674.10892.1.1700.20.1.11

Description

Defines the DRS events filter mask for this remote access user.

Syntax

DellUnsigned32BitRange

Access

Read-write

Remote User Admin Alert Filter System Events Mask
Name

remoteUserAdminAlertFilterSysEventsMask

Object ID

1.3.6.1.4.1.674.10892.1.1700.20.1.12

Description

Defines the system events filter mask for this remote access user.

Syntax

DellUnsigned32BitRange

Access

Read-write

492

Remote Access Group

Remote User Admin Alert Filter DRS Capabilities
Name

remoteUserAdminAlertFilterDrsCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.1700.20.1.13

Description

Defines the DRS events filter capabilities for this remote access user.

Syntax

DellUnsigned32BitRange

Access

Read-only

Remote User Admin Alert Filter System Capabilities
Name

remoteUserAdminAlertFilterSysCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.1700.20.1.14

Description

Defines the system events filter capabilities for this remote
access user.

Syntax

DellUnsigned32BitRange

Access

Read-only

Remote User Admin Pager Numeric Number Name
Name

remoteUserAdminPagerNumericNumberName

Object ID

1.3.6.1.4.1.674.10892.1.1700.20.1.15

Description

Defines the numeric pager number for this remote access user.

Syntax

DisplayString (SIZE (0..95))

Access

Read-write

Remote User Admin Pager Numeric Message Name
Name

remoteUserAdminPagerNumericMessageName

Object ID

1.3.6.1.4.1.674.10892.1.1700.20.1.16

Description

Defines the message to send to the numeric pager for this remote
access user.

Syntax

DisplayString (SIZE (0..31))

Access

Read-write

Remote Access Group

493

Remote User Admin Pager Numeric Hang-up Delay
Name

remoteUserAdminPagerNumericHangupDelay

Object ID

1.3.6.1.4.1.674.10892.1.1700.20.1.17

Description

Defines the numeric pager hang-up delay for this remote access user.

Syntax

DellUnsigned32BitRange

Access

Read-write

Remote User Admin Pager Alpha Phone Number Name
Name

remoteUserAdminPagerAlphaPhoneNumberName

Object ID

1.3.6.1.4.1.674.10892.1.1700.20.1.18

Description

Defines the alphanumeric pager phone number for this remote
access user.

Syntax

DisplayString (SIZE (0..95))

Access

Read-write

Remote User Admin Pager Alpha Protocol
Name

remoteUserAdminPagerAlphaProtocol

Object ID

1.3.6.1.4.1.674.10892.1.1700.20.1.19

Description

Defines the protocol used by the alphanumeric pager provider
for this remote access user.

Syntax

DellRemoteUserAdminAlphaProtocolType (See Table 20-16)

Access

Read-write

Remote User Admin Pager Alpha Baud Rate
Name

remoteUserAdminPagerAlphaBaudRate

Object ID

1.3.6.1.4.1.674.10892.1.1700.20.1.20

Description

Defines the baud rate used by the alphanumeric pager provider
for this remote access user.

Syntax

DellRemoteUserAdminAlphaBaudType (See Table 20-17)

Access

Read-write

494

Remote Access Group

Remote User Admin Pager Alpha Custom Message Name
Name

remoteUserAdminPagerAlphaCustomMessageName

Object ID

1.3.6.1.4.1.674.10892.1.1700.20.1.21

Description

Defines the message to be sent to the alphanumeric pager to
inform the user of a call by this remote access user.

Syntax

DisplayString (SIZE (0..31))

Access

Read-write

Remote User Admin Pager Alpha Modem Connect Time-out
Name

remoteUserAdminPagerAlphaModemConnectTimeout

Object ID

1.3.6.1.4.1.674.10892.1.1700.20.1.22

Description

Defines the modem connection time-out for the alphanumeric
pager for this remote access user.

Syntax

DellUnsigned32BitRange

Access

Read-write

Remote User Admin Pager Alpha Pager ID Name
Name

remoteUserAdminPagerAlphaPagerIdName

Object ID

1.3.6.1.4.1.674.10892.1.1700.20.1.23

Description

Defines the ID to be sent to the alphanumeric pager to inform
the user of a call by this remote access user.

Syntax

DisplayString (SIZE (0..31))

Access

Read-write

Remote User Admin Pager Alpha Password Name
Name

remoteUserAdminPagerAlphaPasswordName

Object ID

1.3.6.1.4.1.674.10892.1.1700.20.1.24

Description

Defines the password for the alphanumeric pager for this remote
access user.

Syntax

DisplayString (SIZE (0..31))

Access

Read-write

Remote Access Group

495

Remote User Admin Pager Modem Init String Name
Name

remoteUserAdminPagerModemInitStringName

Object ID

1.3.6.1.4.1.674.10892.1.1700.20.1.25

Description

Defines the initialization string to be sent to the pager modem
for this remote access user.

Syntax

DisplayString (SIZE (0..31))

Access

Read-write

Remote User Admin Pager Modem Port
Name

remoteUserAdminPagerModemPort

Object ID

1.3.6.1.4.1.674.10892.1.1700.20.1.26

Description

Defines the port for the pager modem for this remote access
user.

Syntax

DellUnsigned32BitRange

Access

Read-write

Remote User Admin E-Mail Address Name
Name

remoteUserAdminEmailAddressName

Object ID

1.3.6.1.4.1.674.10892.1.1700.20.1.27

Description

Defines the e-mail address for this remote access user.

Syntax

DisplayString (SIZE (0..63))

Access

Read-write

Remote User Admin E-Mail Custom Message Name
Name

remoteUserAdminEmailCustomMessageName

Object ID

1.3.6.1.4.1.674.10892.1.1700.20.1.28

Description

Defines the e-mail message to send to this remote access user.

Syntax

DisplayString (SIZE (0..31))

Access

Read-write

496

Remote Access Group

Remote User Admin Control Capabilities
Name

remoteUserAdminControlCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.1700.20.1.29

Description

Defines the control capabilities for this remote access user.

Syntax

DellRemoteUserAdminControlCapabilities (See Table 20-14 on
page 519)

Access

Read-only

Remote User Admin Control Settings
Name

remoteUserAdminControlSettings

Object ID

1.3.6.1.4.1.674.10892.1.1700.20.1.30

Description

Defines the control settings for this remote access user.

Syntax

DellRemoteUserAdminControlSettings (See Table 20-15)

Access

Read-write

Remote User Admin User Type
Name

remoteUserAdminUserType

Object ID

1.3.6.1.4.1.674.10892.1.1700.20.1.31

Description

Defines the type of user for this remote access user.

Syntax

DellUnsigned8BitRange

Access

Read-write

Remote SNMP Trap Table
Name

remoteSNMPTrapTable

Object ID

1.3.6.1.4.1.674.10892.1.1700.30

Description

Defines the Remote Access SNMP Trap Destination Table.

Syntax

SEQUENCE OF RemoteSNMPTrapTableEntry

Access

Not accessible

Remote Access Group

497

Remote SNMP Trap Table Entry
Name

remoteSNMPTrapTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.1700.30.1

Description

Defines the Remote Access SNMP Trap Destination Table entry.

Syntax

RemoteSNMPTrapTableEntry

Access

Not accessible

Index

remoteSNMPTrapChassisIndex,
remoteSNMPTrapAdapterIndex, remoteSNMPTrapIndex

Remote SNMP Trap Chassis Index
Name

remoteSNMPTrapChassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.1700.30.1.1

Description

Defines the index (one-based) of the chassis containing the
remote access hardware.

Syntax

DellObjectRange

Access

Read-only

Remote SNMP Trap Adapter Index
Name

remoteSNMPTrapAdapterIndex

Object ID

1.3.6.1.4.1.674.10892.1.1700.30.1.2

Description

Defines the index (one-based) of the remote access hardware
that uses this SNMP trap destination.

Syntax

DellObjectRange

Access

Read-only

498

Remote Access Group

Remote SNMP Trap Index
Name

remoteSNMPTrapIndex

Object ID

1.3.6.1.4.1.674.10892.1.1700.30.1.3

Description

Defines the index (one-based) of this remote access SNMP trap
destination.

Syntax

DellObjectRange

Access

Read-only

Remote SNMP Trap State Capabilities
Name

remoteSNMPTrapStateCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.1700.30.1.4

Description

Defines the state capabilities of this remote access SNMP trap
destination.

Syntax

DellRemoteSNMPTrapStateCapabilities (See Table 20-18)

Access

Read-only

Remote SNMP Trap State Settings
Name

remoteSNMPTrapStateSettings

Object ID

1.3.6.1.4.1.674.10892.1.1700.30.1.5

Description

Defines the state settings of this remote access SNMP trap
destination.

Syntax

DellRemoteSNMPTrapStateSettings (See Table 20-19)

Access

Read-write

Remote SNMP Trap Status
Name

remoteSNMPTrapStatus

Object ID

1.3.6.1.4.1.674.10892.1.1700.30.1.6

Description

Defines the status of this remote access SNMP trap destination.

Syntax

DellStatus

Access

Read-only
Remote Access Group

499

Remote SNMP Trap Destination IP Address
Name

remoteSNMPTrapDestinationIPAddress

Object ID

1.3.6.1.4.1.674.10892.1.1700.30.1.7

Description

Defines the IP address of this remote access SNMP trap destination.

Syntax

IpAddress

Access

Read-write

Remote SNMP Trap SNMP Community Name
Name

remoteSNMPTrapSNMPCommunityName

Object ID

1.3.6.1.4.1.674.10892.1.1700.30.1.8

Description

Defines the community for traps sent to this remote access
SNMP trap destination.

Syntax

DisplayString (SIZE (0..31))

Access

Read-write

Remote SNMP Trap Filter DRS Events Mask
Name

remoteSNMPTrapFilterDrsEventsMask

Object ID

1.3.6.1.4.1.674.10892.1.1700.30.1.9

Description

Defines the DRS events filter mask for this remote access
SNMP trap destination.

Syntax

DellUnsigned32BitRange

Access

Read-write

Remote SNMP Trap Filter System Events Mask
Name

remoteSNMPTrapFilterSysEventsMask

Object ID

1.3.6.1.4.1.674.10892.1.1700.30.1.10

Description

Defines the system events filter mask for this remote access
SNMP trap destination.

Syntax

DellUnsigned32BitRange

Access

Read-write

500

Remote Access Group

Remote SNMP Trap Filter DRS Capabilities
Name

remoteSNMPTrapFilterDrsCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.1700.30.1.11

Description

Defines the DRS events filter capabilities for this remote access
SNMP trap destination.

Syntax

DellUnsigned32BitRange

Access

Read-only

Remote SNMP Trap Filter System Capabilities
Name

remoteSNMPTrapFilterSysCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.1700.30.1.12

Description

Defines the system events filter capabilities of this remote
access SNMP trap destination.

Syntax

DellUnsigned32BitRange

Access

Read-only

Remote SNMP Trap Control Capabilities
Name

remoteSNMPTrapControlCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.1700.30.1.13

Description

Defines the control capabilities of this remote access
SNMP trap destination.

Syntax

DellRemoteSNMPTrapControlCapabilities (See Table 20-20)

Access

Read-only

Remote SNMP Trap Control Settings
Name

remoteSNMPTrapControlSettings

Object ID

1.3.6.1.4.1.674.10892.1.1700.30.1.14

Description

Defines the control settings of this remote access SNMP
trap destination.

Syntax

DellRemoteSNMPTrapControlSettings (See Table 20-21)

Access

Read-write

Remote Access Group

501

Remote Dial-Up Table
Name

remoteDialUpTable

Object ID

1.3.6.1.4.1.674.10892.1.1700.40

Description

Defines the Remote Access Dial-Up Table.

Syntax

SEQUENCE OF RemoteDialUpTableEntry

Access

Not accessible

Remote Dial-Up Table Entry
Name

remoteDialUpTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.1700.40.1

Description

Defines the Remote Access Dial-Up Table entry.

Syntax

RemoteDialUpTableEntry

Access

Not accessible

Index

remoteDialUpChassisIndex, remoteDialUpAdapterIndex,
remoteDialUpIndex

Remote Dial-Up Chassis Index
Name

remoteDialUpChassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.1700.40.1.1

Description

Defines the index (one-based) of the chassis containing the
remote access hardware.

Syntax

DellObjectRange

Access

Read-only

502

Remote Access Group

Remote Dial-Up Adapter Index
Name

remoteDialUpAdapterIndex

Object ID

1.3.6.1.4.1.674.10892.1.1700.40.1.2

Description

Defines the index (one-based) of the remote access hardware
that supports this remote access dial-up functionality.

Syntax

DellObjectRange

Access

Read-only

Remote Dial-Up Index
Name

remoteDialUpIndex

Object ID

1.3.6.1.4.1.674.10892.1.1700.40.1.3

Description

Defines the index (one-based) of this remote access dial-up
functionality.

Syntax

DellObjectRange

Access

Read-only

Remote Dial-Up State Capabilities
Name

remoteDialUpStateCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.1700.40.1.4

Description

Defines the state capabilities of this remote access dial-up
functionality.

Syntax

DellRemoteDialUpStateCapabilities (See Table 20-22)

Access

Read-only

Remote Dial-Up State Settings
Name

remoteDialUpStateSettings

Object ID

1.3.6.1.4.1.674.10892.1.1700.40.1.5

Description

Defines the state settings of this remote access dial-up
functionality.

Syntax

DellRemoteDialUpStateSettings (See Table 20-23)

Access

Read-write

Remote Access Group

503

Remote Dial-Up Status
Name

remoteDialUpStatus

Object ID

1.3.6.1.4.1.674.10892.1.1700.40.1.6

Description

Defines the status of this remote access dial-up functionality.

Syntax

DellStatus

Access

Read-only

Remote Dial-Up PPP Dial-In Base IP Address
Name

remoteDialUpPPPDialInBaseIPAddress

Object ID

1.3.6.1.4.1.674.10892.1.1700.40.1.7

Description

Defines the base IP address of the PPP server for this remote
access dial-up functionality.

Syntax

IpAddress

Access

Read-write

Remote Dial-Up PPP Dial-In Idle Time-out
Name

remoteDialUpPPPDialInIdleTimeout

Object ID

1.3.6.1.4.1.674.10892.1.1700.40.1.8

Description

Defines the PPP idle time-out value in seconds for this remote
access dial-up functionality.

Syntax

DellUnsigned32BitRange

Access

Read-write

Remote Dial-Up PPP Dial-In Maximum Connection Time-out
Name

remoteDialUpPPPDialInMaxConnectTimeout

Object ID

1.3.6.1.4.1.674.10892.1.1700.40.1.9

Description

Defines the PPP connect time-out value in seconds for this
remote access dial-up functionality.

Syntax

DellUnsigned32BitRange

Access

Read-write

504

Remote Access Group

Remote Dial-Up Dial-Out Modem Connect Time-out
Name

remoteDialUpDialOutModemConnectTimeout

Object ID

1.3.6.1.4.1.674.10892.1.1700.40.1.10

Description

Defines the modem dial-out time-out value in seconds for this
remote access dial-up functionality.

Syntax

DellUnsigned32BitRange

Access

Read-write

Remote Dial-Up Modem Dial Type
Name

remoteDialUpModemDialType

Object ID

1.3.6.1.4.1.674.10892.1.1700.40.1.11

Description

Defines the dial type for the modem used by this remote access
dial-up functionality.

Syntax

DellRemoteDialUpModemDialType (See Table 20-24)

Access

Read-write

Remote Dial-Up Modem Init String Name
Name

remoteDialUpModemInitStringName

Object ID

1.3.6.1.4.1.674.10892.1.1700.40.1.12

Description

Defines the initialization string to be sent to the modem for this
remote access dial-up functionality.

Syntax

DisplayString (SIZE (0..63))

Access

Read-write

Remote Dial-Up Modem Baud Rate
Name

remoteDialUpModemBaudRate

Object ID

1.3.6.1.4.1.674.10892.1.1700.40.1.13

Description

Defines the baud rate for the modem used by this remote access
dial-up functionality.

Syntax

DellUnsigned32BitRange

Access

Read-write

Remote Access Group

505

Remote Dial-Up Modem Port
Name

remoteDialUpModemPort

Object ID

1.3.6.1.4.1.674.10892.1.1700.40.1.14

Description

Defines the port for the modem used by this remote access dialup functionality.

Syntax

DellUnsigned32BitRange

Access

Read-write

Remote User Dial-In Configuration Table
Name

remoteUserDialInCfgTable

Object ID

1.3.6.1.4.1.674.10892.1.1700.50

Description

Defines the Remote Access User Dial-In Configuration Table.

Syntax

SEQUENCE OF RemoteUserDialInCfgTableEntry

Access

Not accessible

Remote User Dial-In Configuration Table Entry
Name

remoteUserDialInCfgTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.1700.50.1

Description

Defines the Remote Access User Dial-In Configuration Table
entry.

Syntax

RemoteUserDialInCfgTableEntry

Access

Not accessible

Index

remoteUserDialInCfgChassisIndex,
remoteUserDialInCfgAdapterIndex,
remoteUserDialInCfgUserIndex

506

Remote Access Group

Remote User Dial-In Configuration Chassis Index
Name

remoteUserDialInCfgChassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.1700.50.1.1

Description

Defines the index (one-based) of the chassis containing the
remote access hardware.

Syntax

DellObjectRange

Access

Read-only

Remote User Dial-In Configuration Adapter Index
Name

remoteUserDialInCfgAdapterIndex

Object ID

1.3.6.1.4.1.674.10892.1.1700.50.1.2

Description

Defines the index (one-based) of the remote access hardware
that supports this remote access dial-in user.

Syntax

DellObjectRange

Access

Read-only

Remote User Dial-In Configuration User Index
Name

remoteUserDialInCfgUserIndex

Object ID

1.3.6.1.4.1.674.10892.1.1700.50.1.3

Description

Defines the index (one-based) of this remote access dial-in user.

Syntax

DellObjectRange

Access

Read-only

Remote User Dial-In Configuration State Capabilities
Name

remoteUserDialInCfgStateCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.1700.50.1.4

Description

Defines the state capabilities of this remote access dial-in user.

Syntax

DellRemoteUserDialInStateCapabilities (See Table 20-25)

Access

Read-only

Remote Access Group

507

Remote User Dial-In Configuration State Settings
Name

remoteUserDialInCfgStateSettings

Object ID

1.3.6.1.4.1.674.10892.1.1700.50.1.5

Description

Defines the state settings of this remote access dial-in user.

Syntax

DellRemoteUserDialInStateSettings (See Table 20-26)

Access

Read-write

Remote User Dial-In Configuration Status
Name

remoteUserDialInCfgStatus

Object ID

1.3.6.1.4.1.674.10892.1.1700.50.1.6

Description

Defines the status of this remote access dial-in user.

Syntax

DellStatus

Access

Read-only

Remote User Dial-In Configuration PPP Username
Name

remoteUserDialInCfgPPPUserName

Object ID

1.3.6.1.4.1.674.10892.1.1700.50.1.7

Description

Defines the PPP user name of this remote access dial-in user.

Syntax

DisplayString (SIZE (0..15))

Access

Read-write

Remote User Dial-In Configuration PPP User Password Name
Name

remoteUserDialInCfgPPPUserPasswordName

Object ID

1.3.6.1.4.1.674.10892.1.1700.50.1.8

Description

Defines the PPP password of this remote access dial-in user.

Syntax

DisplayString (SIZE (0..15))

Access

Read-write

508

Remote Access Group

Remote User Dial-In Configuration Callback Phone Number Name
Name

remoteUserDialInCfgCallbackPhoneNumberName

Object ID

1.3.6.1.4.1.674.10892.1.1700.50.1.9

Description

Defines the callback phone number for this remote access dial-in user.

Syntax

DisplayString (SIZE (0..95))

Access

Read-write

Remote Dial-Out Table
Name

remoteDialOutTable

Object ID

1.3.6.1.4.1.674.10892.1.1700.60

Description

Defines the Remote Access Dial-Out Table.

Syntax

SEQUENCE of RemoteDialOutTableEntry

Access

Not accessible

Remote Dial-Out Table Entry
Name

remoteDialOutTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.1700.60.1

Description

Defines the Remote Access Dial-Out Table entry.

Syntax

RemoteDialOutTableEntry

Access

Not accessible

Index

remoteDialOutChassisIndex, remoteDialOutAdapterIndex,
remoteDialOutDialOutIndex

Remote Dial-Out Chassis Index
Name

remoteDialOutChassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.1700.60.1.1

Description

Defines the index (one-based) of the chassis containing the
remote access hardware.

Syntax

DellObjectRange

Access

Read-only

Remote Access Group

509

Remote Dial-Out Adapter Index
Name

remoteDialOutAdapterIndex

Object ID

1.3.6.1.4.1.674.10892.1.1700.60.1.2

Description

Defines the index (one-based) of the remote access hardware
that supports this remote access dial-out functionality.

Syntax

DellObjectRange

Access

Read-only

Remote Dial-Out Dial-Out Index
Name

remoteDialOutDialOutIndex

Object ID

1.3.6.1.4.1.674.10892.1.1700.60.1.3

Description

Defines the index (one-based) of this remote access dial-out
functionality.

Syntax

DellObjectRange

Access

Read-only

Remote Dial-Out State Capabilities
Name

remoteDialOutStateCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.1700.60.1.4

Description

Defines the state capabilities of this remote access dial-out
functionality.

Syntax

DellRemoteDialOutStateCapabilities (See Table 20-27)

Access

Read-only

Remote Dial-Out State Settings
Name

remoteDialOutStateSettings

Object ID

1.3.6.1.4.1.674.10892.1.1700.60.1.5

Description

Defines the state settings of this remote access dial-out functionality.

Syntax

DellRemoteDialOutStateSettings (See Table 20-28)

Access

Read-write

510

Remote Access Group

Remote Dial-Out Status
Name

remoteDialOutStatus

Object ID

1.3.6.1.4.1.674.10892.1.1700.60.1.6

Description

Defines the status of this remote access dial-out functionality.

Syntax

DellStatus

Access

Read-only

Remote Dial-Out IP Address
Name

remoteDialOutIPAddress

Object ID

1.3.6.1.4.1.674.10892.1.1700.60.1.7

Description

Defines the IP address for this remote access dial-out
destination.

Syntax

IpAddress

Access

Read-write

Remote Dial-Out Phone Number Name
Name

remoteDialOutPhoneNumberName

Object ID

1.3.6.1.4.1.674.10892.1.1700.60.1.8

Description

Defines the phone number for this remote access dial-out
destination.

Syntax

DisplayString (SIZE (0..95))

Access

Read-write

Remote Dial-Out PPP Username
Name

remoteDialOutPPPUserName

Object ID

1.3.6.1.4.1.674.10892.1.1700.60.1.9

Description

Defines the PPP username for this remote access dial-out
destination.

Syntax

DisplayString (SIZE (0..31))

Access

Read-write
Remote Access Group

511

Remote Dial-Out PPP Password Name
Name

remoteDialOutPPPPasswordName

Object ID

1.3.6.1.4.1.674.10892.1.1700.60.1.10

Description

Defines the PPP password for this remote access dial-out destination.

Syntax

DisplayString (SIZE (0..31))

Access

Read-write

Remote Access Variable Values
This section includes definitions for server administrator-specific variable
values used in this section.
Table 20-1. Remote Access Type
Variable Name: DellRemoteAccessType
Data Type: Integer
Possible Data Values

Meaning of Data Value

remoteAccessTypeIsOther(1)

The remote access type is not one of
the following:

remoteAccessTypeIsUnknown(2) The remote access type is unknown.
remoteAccessTypeIsDRACIII(3) The remote access type is DRAC III.
remoteAccessTypeIsERA(4)

The remote access type is ERA.

Table 20-2. Remote Access Control Capabilities
Variable Name: DellRemoteAccessControlCapabilities
Data Type: Integer
Possible Data Values

Meaning of Data Value

none(0)

The remote access hardware has no
control capabilities.

unknownCapabilities(1)

The remote access hardware control
capabilities are unknown.

512

Remote Access Group

Table 20-2.

Remote Access Control Capabilities (continued)

Variable Name: DellRemoteAccessControlCapabilities
Data Type: Integer
Possible Data Values

Meaning of Data Value

logResetCapable(2)

The remote access hardware can reset
its integrated logs.

hardResetCapable(4)

The remote access hardware can
perform a hard reset.

softResetCapable(8)

The remote access hardware can
perform a soft reset.

gracefulResetCapable(16)

The remote access hardware can
gracefully shut down and perform a
soft reset.

defaultConfigResetCapable(32) The remote access hardware can reset
to its default settings.
shutdownCapable(64)

Table 20-3.

The remote access hardware can
shut down.

Remote Access Control Settings

Variable Name: DellRemoteAccessControlSettings
Data Type: Integer
Possible Data Values

Meaning of Data Value

none(0)

The remote access hardware has no control settings.

unknown(1)

The remote access hardware control settings are
unknown.

logReset(2)

The remote access hardware resets its
integrated logs.

hardReset(4)

The remote access hardware performs a hard reset.

softReset(8)

The remote access hardware performs a soft reset.

gracefulReset(16)

The remote access hardware shuts down and
perform a soft reset.

Remote Access Group

513

Table 20-3. Remote Access Control Settings (continued)
Variable Name: DellRemoteAccessControlSettings
Data Type: Integer
Possible Data Values

Meaning of Data Value

defaultConfigReset(32) The remote access hardware resets to its default
settings.
shutdown(64)

The remote access hardware shuts down.

Table 20-4. Remote Access Monitor Capabilities
Variable Name: DellRemoteAccessMonitorCapabilities
Data Type: Integer
Possible Data Values

Meaning of Data Value

none(0)

The remote access hardware has no
monitor capabilities.

unknownCapabilities(1)

The remote access hardware monitor
capabilities are unknown.

extPwrSupplyMonitorIfConn The remote access hardware can be set to
ectedCapable(2)
monitor the external power supply, if
connected.
extPwrSupplyMonitorAlways The remote access hardware can be set to
EnabledCapable(4)
always monitor the external power supply.

514

Remote Access Group

Table 20-5.

Remote Access Monitor Settings

Variable Name: DellRemoteAccessMonitorSettings
Data Type: Integer
Possible Data Values

Meaning of Data Value

none(0)

The remote access hardware has no
monitor settings.

unknown(1)

The remote access hardware monitor settings
are unknown.

extPwrSupplyMonitorIfConn The remote access hardware monitors the
ectedEnabled(2)
external power supply, if connected.
extPwrSupplyMonitorAlways The remote access hardware always monitors
EnabledEnabled(4)
the external power supply.
Table 20-6.

Remote Access Local Area Network (LAN) Capabilities

Variable Name: DellRemoteAccessLANCapabilities
Data Type: Integer
Possible Data Values

Meaning of Data Value

none(0)

The remote access hardware has no
LAN capabilities.

unknownCapabilities(1)

The remote access hardware LAN capabilities
are unknown.

nicCapable(2)

The remote access hardware has a network
interface controller (NIC).

nicDHCPCapable(4)

The remote access hardware NIC can use
DHCP to obtain an IP address.

Remote Access Group

515

Table 20-7. Remote Access LAN Settings
Variable Name: DellRemoteAccessLANSettings
Data Type: Integer
Possible Data Values

Meaning of Data Value

none(0)

The remote access hardware has no LAN
settings.

unknown(1)

The remote access hardware LAN settings are
unknown.

nicEnabled(2)

The remote access hardware NIC is enabled.

nicDHCPEnabled(4)

The remote access hardware NIC uses DHCP
to obtain an IP address.

Table 20-8. Remote Access Host Capabilities
Variable Name: DellRemoteAccessHostCapabilities
Data Type: Integer
Possible Data Values

Meaning of Data Value

none(0)

The remote access hardware has no
host capabilities.

unknownCapabilities(1)

The remote access hardware host
capabilities are unknown.

smtpEmailCapable(2)

The remote access hardware
supports sending e-mail using SMTP.

tftpRemoteFloppyCapable(4)

The remote access hardware supports
remote floppy boot using a TFTP server.

tftpRemoteFwUpdateCapable(8) The remote access hardware supports
remote firmware update using a TFTP
server.

516

Remote Access Group

Table 20-9.

Remote Access Host Settings

Variable Name: DellRemoteAccessHostSettings
Data Type: Integer
Possible Data Values

Meaning of Data Value

none(0)

The remote access hardware has no host
settings.

unknown(1)

The remote access hardware host settings
are unknown.

smtpEmailEnabled(2)

The remote access hardware SMTP client
is enabled for sending e-mail.

tftpRemoteFloppyEnabled(4)

The remote access hardware TFTP client
is enabled for remote floppy boot.

tftpRemoteFwUpdateEnabled(8) The remote access hardware TFTP client
is enabled for remote firmware update.
Table 20-10. Remote Access Out-Of-Band Simple Network Management Protocol
(SNMP) Capabilities
Variable Name: DellRemoteAccessOutOfBandSNMPCapabilities
Data Type: Integer
Possible Data Values

Meaning of Data Value

none(0)

The remote access hardware has no out-of-band
SNMP capabilities.

unknownCapabilities(1) The remote access hardware out-of-band SNMP
capabilities are unknown.
oobSNMPAgentCapable(2) The remote access hardware has an out-of-band
SNMP agent.
oobSNMPTrapsCapable(4) The remote access hardware can send out-of-band
SNMP traps.

Remote Access Group

517

Table 20-11. Remote Access Out-Of-Band Simple Network Management Protocol
(SNMP) Settings
Variable Name: DellRemoteAccessOutOfBandSNMPSettings
Data Type: Integer
Possible Data Values

Meaning of Data Value

none(0)

The remote access hardware has no out-of-band
SNMP settings.

unknown(1)

The remote access hardware out-of-band SNMP
settings are unknown.

oobSNMPAgentEnabled(2) The remote access hardware out-of-band SNMP
agent is enabled.
oobSNMPTrapsEnabled(4) The remote access hardware sends out-of-band
SNMP traps.
Table 20-12. Remote User Admin State Capabilities
Variable Name: DellRemoteUserAdminStateCapabilities
Data Type: Integer
Possible Data Values

Meaning of Data Value

none(0)

The admin user has no state capabilities.

unknownCapabilities(1) The admin user state capabilities are unknown.
enableCapable(2)

The admin user can be disabled or enabled.

notReadyCapable(4)

The admin user can be in the not ready state.

numericPagerCapable(8) The admin user supports numeric paging.
alphaPagerCapable(16)

The admin user supports alphanumeric paging.

emailCapable(32)

The admin user supports e-mail.

privilegeCapable(64)

The admin user supports user privileges
configuration.

518

Remote Access Group

Table 20-13. Remote User Admin State Settings
Variable Name: DellRemoteUserAdminStateSettings
Data Type: Integer
Possible Data Values

Meaning of Data Value

none(0)

The admin user has no state settings.

unknown(1)

The admin user state settings are unknown.

enabled(2)

The admin user is enabled.

notReady(4)

The admin user is in the not ready state.

numericPagerEnabled(8) Numeric paging is enabled for the admin user.
alphaPagerEnabled(16)

Alphanumeric paging is enabled for the admin
user.

emailEnabled(32)

E-mail is enabled for the admin user.

Table 20-14. Remote User Admin Control Capabilities
Variable Name: DellRemoteUserAdminControlCapabilities
Data Type: Integer
Possible Data Values

Meaning of Data Value

none(0)

The admin user has no control capabilities.

unknownCapabilities(1)

The admin user control capabilities are
unknown.

numericPagerTestCapable(2) The admin user can support sending a test
numeric page.
alphaPagerTestCapable(4)

The admin user can support sending a test
alphanumeric page.

emailTestCapable(8)

The admin user can support sending a test
e-mail.

Remote Access Group

519

Table 20-15. Remote User Admin Control Settings
Variable Name: DellRemoteUserAdminControlSettings
Data Type: Integer
Possible Data Values

Meaning of Data Value

none(0)

The admin user has no control settings.

unknown(1)

The admin user control settings are unknown.

numericPagerTest(2) A numeric pager test is performed for the admin user.
alphaPagerTest(4)

An alphanumeric pager test is performed for the
admin user.

emailTest(8)

An e-mail test is performed for the admin user.

Table 20-16. Remote User Admin Alpha Protocol Type
Variable Name: DellRemoteUserAdminAlphaProtocolType
Data Type: Integer
Possible Data Values

Meaning of Data Value

other(1)

The remote user admin alpha protocol type is not one
of the following:

unknown(2)

The remote user admin alpha protocol type is
unknown.

alpha7E0(3)

The remote user admin alpha protocol type is 7E0.

alpha8N1(4)

The remote user admin alpha protocol type is 8N1.

520

Remote Access Group

Table 20-17. Remote User Admin Alpha Baud Type
Variable Name: DellRemoteUserAdminAlphaBaudType
Data Type: Integer
Possible Data Values

Meaning of Data Value

other(1)

The remote user alphanumeric baud rate is not one
of the following:

unknown(2)

The remote user alphanumeric baud rate is unknown.

alphaBaud300(3)

The remote user alphanumeric baud rate is 300.

alphaBaud1200(4)

The remote user alphanumeric baud rate is 1200.

Table 20-18. Remote SNMP Trap State Capabilities
Variable Name: DellRemoteSNMPTrapStateCapabilities
Data Type: Integer
Possible Data Values

Meaning of Data Value

none(0)

The SNMP trap destination has no state capabilities.

unknownCapabilities The SNMP trap destination state capabilities
(1)
are unknown.
enableCapable(2)

The SNMP trap destination can be disabled or enabled.

notReadyCapable(4)

The SNMP trap destination can be in the not ready
state.

Table 20-19. Remote SNMP Trap State Settings
Variable Name: DellRemoteSNMPTrapStateSettings
Data Type: Integer
Possible Data Values

Meaning of Data Value

none(0)

The SNMP trap destination has no state settings.

unknown(1)

The SNMP trap destination state settings are unknown.

enabled(2)

The SNMP trap destination is enabled.

notReady(4)

The SNMP trap destination is in the not ready state.

Remote Access Group

521

Table 20-20. Remote SNMP Trap Control Capabilities
Variable Name: DellRemoteSNMPTrapControlCapabilities
Data Type: Integer
Possible Data Values

Meaning of Data Value

none(0)

The SNMP trap destination has no control capabilities.

unknownCapabilities The SNMP trap destination control capabilities are
(1)
unknown.
trapTestCapable(2)

A SNMP trap test can be performed for the SNMP trap
destination.

Table 20-21. Remote SNMP Trap Control Settings
Variable Name: DellRemoteSNMPTrapControlSettings
Data Type: Integer
Possible Data Values

Meaning of Data Value

none(0)

The SNMP trap destination has no control settings.

unknown(1)

The SNMP trap destination control settings are
unknown.

trapTestCapable(2)

A SNMP trap test is performed for the SNMP trap
destination.

Table 20-22. Remote Dial-Up State Capabilities
Variable Name: DellRemoteDialUpStateCapabilities
Data Type: Integer
Possible Data Values

Meaning of Data Value

none(0)

The dial-up functionality has no
state capabilities.

unknownCapabilities(1)

The dial-up functionality state
capabilities are unknown.

enableCapable(2)

The dial-up functionality can be
disabled or enabled.

522

Remote Access Group

Table 20-22. Remote Dial-Up State Capabilities (continued)
Variable Name: DellRemoteDialUpStateCapabilities
Data Type: Integer
Possible Data Values

Meaning of Data Value

notReadyCapable(4)

The dial-up functionality can be in
the not ready state.

dialInCapable(8)

The dial-up functionality can
support the dial-in feature.

dialOutCapable(16)

The dial-up functionality can
support the dial-out feature.

dialInDHCPCapable(32)

The dial-up functionality can
support using DHCP to obtain an
IP address for the dial-in feature.

dialInAuthAnyCapable(64)

The dial-up functionality can support
any authentication type (including
clear text) for the dial-in feature.

dialInAuthEncryptedCapable(128) The dial-up functionality can support
encrypted passwords (CHAP)
authentication for the dial-in feature.
dialInAuthMschapCapable(256)

The dial-up functionality can
support MSCHAP authentication
type for the dial-in feature.

Table 20-23. Remote Dial-Up State Settings
Variable Name: DellRemoteDialUpStateSettings
Data Type: Integer
Possible Data Values

Meaning of Data Value

none(0)

The dial-up functionality has no state settings.

unknown(1)

The dial-up functionality state settings are unknown.

enabled(2)

The dial-up functionality is enabled.

notReadyCapable(4)

The dial-up functionality is in the not ready state.

dialInEnabled(8)

The dial-up functionality dial-in feature is enabled.

dialOutEnabled(16)

The dial-up functionality dial-out feature is enabled.
Remote Access Group

523

Table 20-23. Remote Dial-Up State Settings (continued)
Variable Name: DellRemoteDialUpStateSettings
Data Type: Integer
Possible Data Values

Meaning of Data Value

dialInDHCPEnabled(32) The dial-up functionality uses DHCP to obtain an IP
address for the dial-in feature.
dialInAuthAnyEnabled The dial-up functionality accepts any authentication
(64)
type (including clear text) for the dial-in feature.
dialInAuthEncrypted The dial-up functionality uses only encrypted
Enabled(128)
passwords (CHAP) authentication type for the dialin feature.
dialInAuthMschapEnab The dial-up functionality uses only MSCHAP
led(256)
authentication type for the dial-in feature.
Table 20-24. Remote Dial-Up Modem Dial Type
Variable Name: DellRemoteDialUpModemDialType
Data Type: Integer
Possible Data Values

Meaning of Data Value

remoteDialUpIsOther(1)

The remote dial type is not one of the
following:

remoteDialUpIsUnknown(2)

The remote dial type is unknown.

remoteDialUpIsTone(3)

The remote dial type is tone.

remoteDialUpIsPulse(4)

The remote dial type is pulse.

524

Remote Access Group

Table 20-25. Remote User Dial-In State Capabilities
Variable Name: DellRemoteUserDialInStateCapabilities
Data Type: Integer
Possible Data Values

Meaning of Data Value

none(0)

The dial-in user has no state capabilities.

unknownCapabilities(1)

The dial-in user state capabilities are
unknown.

enableCapable(2)

The dial-in user can be disabled or
enabled.

notReadyCapable(4)

The dial-in user can be in the not ready
state.

dialInCallbackPresetNumber The dial-in user can support callback
Capable(8)
using a preset number.
dialInCallbackUserSpecified The dial-in user can support callback
Capable(16)
using a user-specified number.
Table 20-26. Remote User Dial-In State Settings
Variable Name: DellRemoteUserDialInStateSettings
Data Type: Integer
Possible Data Values

Meaning of Data Value

none(0)

The dial-in user has no state settings.

unknown(1)

The dial-in user state settings are
unknown.

enabled(2)

The dial-in user is enabled.

notReady(4)

The dial-in user is in the not ready state.

dialInCallbackPresetNumber Callback using a preset number is
Enabled(8)
enabled for the dial-in user.
dialInCallbackUserSpecified Callback using a user-specified number is
Enabled(16)
enabled for the dial-in user.

Remote Access Group

525

Table 20-27. Remote Dial-Out State Capabilities
Variable Name: DellRemoteDialOutStateCapabilities
Data Type: Integer
Possible Data Values

Meaning of Data Value

none(0)

The dial-out destination has no
state capabilities.

unknownCapabilities(1)

The dial-out destination state
capabilities are unknown.

enableCapable(2)

The dial-out destination can be
disabled or enabled.

notReadyCapable(4)

The dial-out destination can be
in the not ready state.

dialOutPPPAuthAnyCapable(8)

The dial-out destination can
support any authentication type
(including clear text) for PPP.

dialOutPPPAuthEncryptedCapable(16) The dial-out destination can
support encrypted passwords
authentication type for PPP.
dialOutPPPAuthMschapCapable(32)

526

Remote Access Group

The dial-out destination can
support MSCHAP
authentication type for PPP.

Table 20-28. Remote Dial-Out State Settings
Variable Name: DellRemoteDialOutStateSettings
Data Type: Integer
Possible Data Values

Meaning of Data Value

none(0)

The dial-out destination has no
state settings.

unknown(1)

The dial-out destination state
settings are unknown.

enabled(2)

The dial-out destination is
disabled or enabled.

notReady(4)

The dial-out destination is in the
not ready state.

dialOutPPPAuthAnyEnabled(8)

The dial-out destination accepts
any authentication type
(including clear text) for PPP.

dialOutPPPAuthEncryptedEnabled(16) The dial-out destination uses only
encrypted passwords
authentication type for PPP.
dialOutPPPAuthMschapEnabled(32)

The dial-out destination uses only
MSCHAP authentication type for
PPP.

Remote Access Group

527

528

Remote Access Group

21

Cluster Group

Clustering combines multiple systems in such a way that they provide services a
single system cannot. Clustering enhances higher availability, scalability,
and management. Higher availability is achieved by using failover clusters,
in which resources can automatically move between two or more systems in the
event of a failure. Scalability is achieved by balancing the load of an application
across several computer systems. Simpler management is achieved by using
virtual servers, as opposed to managing each individual computer system.

Cluster Group
The Cluster Group defines attributes such as the number of systems in the
cluster, capabilities of the cluster, type of cluster, and name of the cluster.

Cluster Table
The following table defines the attributes of the cluster.
Name

clusterTable

Object ID

1.3.6.1.4.1.674.10892.1.1800.10

Description

Defines the Cluster Table.

Syntax

SEQUENCE OF ClusterTableEntry

Access

Not accessible

Cluster Table Entry
Name

clusterTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.1800.10.1

Description

Defines the Cluster Table entry.

Syntax

ClusterTableEntry

Access

Not accessible

Index

clusterChassisIndex, clusterIndex

Cluster Group

529

Cluster Chassis Index
Name

clusterChassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.1800.10.1.1

Description

Defines the index (one-based) of this chassis.

Syntax

DellObjectRange

Access

Read-only

Cluster Index
Name

clusterIndex

Object ID

1.3.6.1.4.1.674.10892.1.1800.10.1.2

Description

Defines the index (one-based) of the cluster.

Syntax

DellObjectRange

Access

Read-only

Cluster State Capabilities
Name

clusterStateCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.1800.10.1.3

Description

Defines the state capabilities of the cluster.

Syntax

DellStateCapabilities

Access

Read-only

Cluster State Settings
Name

clusterStateSettings

Object ID

1.3.6.1.4.1.674.10892.1.1800.10.1.4

Description

Defines the state settings of the cluster.

Syntax

DellStateSettings

Access

Read-write

530

Cluster Group

Cluster Status
Name

clusterStatus

Object ID

1.3.6.1.4.1.674.10892.1.1800.10.1.5

Description

Defines the status of the cluster.

Syntax

DellStatus

Access

Read-only

Cluster Type
Name

clusterType

Object ID

1.3.6.1.4.1.674.10892.1.1800.10.1.6

Description

Defines the type of the cluster.

Syntax

DellClusterType

Access

Read-only

Cluster Type Description Name
Name

clusterTypeDescriptionName

Object ID

1.3.6.1.4.1.674.10892.1.1800.10.1.7

Description

Defines the description name for the type of the cluster.

Syntax

DellString

Access

Read-only

Cluster Name
Name

clusterName

Object ID

1.3.6.1.4.1.674.10892.1.1800.10.1.8

Description

Defines the name of the cluster.

Syntax

DellString

Access

Read-only

Cluster Group

531

Cluster Group Variable Values
This section includes definitions for Server Administrator-specific variable
values used in this section.
Table 21-1. Cluster Type
Variable Name: DellClusterType
Data Type: Integer
Possible Data Values

Meaning of Data Value

unknown(1)

The cluster type is unknown.

highAvailabilityCluster(2) The cluster type is a high-availability cluster.

532

Cluster Group

22

Baseboard Management Controller
Group

The Baseboard Management Controller (BMC) monitors the system for
critical events by communicating with various sensors on the system board
and sends alerts and log events when certain parameters exceed their preset
thresholds. The BMC Group provides information about the BMC that may
be present in your system. In addition to providing general information about
the BMC, this group provides information about the serial and local area
network (LAN) interfaces of the BMC.

Baseboard Management Controller Group Tables
The objects in the BMC group define information about the BMC and the
serial and LAN interfaces that can be used to access the BMC remotely to
perform management activities. Objects for the serial interface define the
serial connection mode, flow control type and bit rate. Objects for the LAN
interface define the media access control (MAC) address, internet protocol
(IP) address, subnet mask and default gateway.
The following MIB tables define the BMC group:
•

Baseboard Management Controller Table

•

Baseboard Management Controller Serial Interface Table

•

Baseboard Management Controller LAN Interface Table

Baseboard Management Controller Table
Name

bmcTable

Object ID

1.3.6.1.4.1.674.10892.1.1900.10

Description

Defines the Baseboard Management Controller Table.

Syntax

SEQUENCE OF BmcTableEntry

Access

Not accessible

Baseboard Management Controller Group

533

BMC Table Entry
Name

bmcTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.1900.10.1

Description

Defines the Baseboard Management Controller (BMC) Table Entry.

Syntax

BmcTableEntry

Access

Not accessible

Index

bmcChassisIndex, bmcIndex

BMC Chassis Index
Name

bmcChassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.1900.10.1.1

Description

Defines the index (one-based) of the associated chassis.

Syntax

DellObjectRange

Access

Read-only

BMC Index
Name

bmcIndex

Object ID

1.3.6.1.4.1.674.10892.1.1900.10.1.2

Description

Defines the index (one-based) of the BMC.

Syntax

DellObjectRange

Access

Read-only

BMC State Capabilities
Name

bmcStateCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.1900.10.1.3

Description

Defines the state capabilities of the BMC.

Syntax

DellStateCapabilities

Access

Read-only

534

Baseboard Management Controller Group

BMC State Settings
Name

bmcStateSettings

Object ID

1.3.6.1.4.1.674.10892.1.1900.10.1.4

Description

Defines the state settings of the BMC.

Syntax

DellStateSettings

Access

Read-write

BMC Status
Name

bmcStatus

Object ID

1.3.6.1.4.1.674.10892.1.1900.10.1.5

Description

Defines the status of the BMC.

Syntax

DellStatus

Access

Read-only

BMC Display Name
Name

bmcDisplayName

Object ID

1.3.6.1.4.1.674.10892.1.1900.10.1.6

Description

Defines the display name of the BMC.

Syntax

DellString

Access

Read-only

BMC Description Name
Name

bmcDescriptionName

Object ID

1.3.6.1.4.1.674.10892.1.1900.10.1.7

Description

Defines the description of the BMC.

Syntax

DisplayString (SIZE (0..255))

Access

Read-only

Baseboard Management Controller Group

535

BMC IPMI Version Name
Name

bmcIPMIVersionName

Object ID

1.3.6.1.4.1.674.10892.1.1900.10.1.8

Description

Defines the version of the Intelligent Platform Management
Interface (IPMI) specification that the BMC supports.

Syntax

DellString

Access

Read-only

BMC GUID
Name

bmcGUID

Object ID

1.3.6.1.4.1.674.10892.1.1900.10.1.9

Description

Defines the Globally Unique ID (GUID) of the BMC.

Syntax

Octet String (SIZE(16))

Access

Read-only

BMC Type
Name

bmcType

Object ID

1.3.6.1.4.1.674.10892.1.1900.10.1.10

Description

Defines the type of the BMC.

Syntax

DellManagementControllerType

Access

Read-only

BMC Module Name
Name

bmcModuleName

Object ID

1.3.6.1.4.1.674.10892.1.1900.10.1.11

Description

Defines the module name for the BMC. The module name is
present only on certain systems, such as modular systems.

Syntax

DellString

Access

Read-only

536

Baseboard Management Controller Group

BMC IPv4 URL Name
Name

bmcIPv4URLName

Object ID

1.3.6.1.4.1.674.10892.1.1900.10.1.12

Description

Defines the IPv4 URL for the BMC. The URL is not present on
all systems.

Syntax

DisplayString (SIZE (0..1024))

Access

Read-only

BMC IPv6 URL Name
Name

bmcIPv6URLName

Object ID

1.3.6.1.4.1.674.10892.1.1900.10.1.13

Description

Defines the IPv6 URL for the BMC. The URL is not present on
all systems.

Syntax

DisplayString (SIZE (0..1024))

Access

Read-only

Baseboard Management Controller Serial Interface Table
Name

bmcSerialInterfaceTable

Object ID

1.3.6.1.4.1.674.10892.1.1900.20

Description

Defines the BMC Serial Interface Table.

Syntax

SEQUENCE OF BmcSerialInterfaceTableEntry

Access

Not accessible

Baseboard Management Controller Group

537

BMC Serial Interface Table Entry
Name

bmcSerialInterfaceTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.1900.20.1

Description

Defines the BMC Serial Interface Table Entry.

Syntax

BmcSerialInterfaceTableEntry

Access

Not accessible

Index

bmcSerialInterfaceChassisIndex,
bmcSerialInterfaceBMCIndex, bmcSerialInterfaceIndex

BMC Serial Interface Chassis Index
Name

bmcSerialInterfaceChassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.1900.20.1.1

Description

Defines the index (one-based) of the associated chassis.

Syntax

DellObjectRange

Access

Read-only

BMC Serial Interface BMC Index
Name

bmcSerialInterfaceBMCIndex

Object ID

1.3.6.1.4.1.674.10892.1.1900.20.1.2

Description

Defines the index (one-based) of the associated BMC.

Syntax

DellObjectRange

Access

Read-only

BMC Serial Interface Index
Name

bmcSerialInterfaceIndex

Object ID

1.3.6.1.4.1.674.10892.1.1900.20.1.3

Description

Defines the index (one-based) of the BMC serial interface.

Syntax

DellObjectRange

Access

Read-only

538

Baseboard Management Controller Group

BMC Serial Interface State Capabilities
Name

bmcSerialInterfaceStateCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.1900.20.1.4

Description

Defines the state capabilities of the BMC serial interface.

Syntax

DellStateCapabilities

Access

Read-only

BMC Serial Interface State Settings
Name

bmcSerialInterfaceStateSettings

Object ID

1.3.6.1.4.1.674.10892.1.1900.20.1.5

Description

Defines the state settings of the BMC serial interface.

Syntax

DellStateSettings

Access

Read-write

BMC Serial Interface Status
Name

bmcSerialInterfaceStatus

Object ID

1.3.6.1.4.1.674.10892.1.1900.20.1.6

Description

Defines the status of the BMC serial interface.

Syntax

DellStatus

Access

Read-only

BMC Serial Interface Channel Number
Name

bmcSerialInterfaceChannelNumber

Object ID

1.3.6.1.4.1.674.10892.1.1900.20.1.7

Description

Defines the BMC channel number of the BMC serial interface.

Syntax

DellUnsigned8BitRange

Access

Read-only

Baseboard Management Controller Group

539

BMC Serial Interface Connection Mode Capabilities
Name

bmcSerialInterfaceConnectionModeCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.1900.20.1.8

Description

Defines the connection mode capabilities of the BMC serial
interface.

Syntax

DellBMCSerialConnectionModeCapabilities

Access

Read-only

BMC Serial Interface Connection Mode Settings
Name

bmcSerialInterfaceConnectionModeSettings

Object ID

1.3.6.1.4.1.674.10892.1.1900.20.1.9

Description

Defines the connection mode settings of the BMC serial
interface.

Syntax

DellBMCSerialConnectionModeSettings

Access

Read-only

BMC Serial Interface Flow Control
Name

bmcSerialInterfaceFlowControl

Object ID

1.3.6.1.4.1.674.10892.1.1900.20.1.10

Description

Defines the flow control type of the BMC serial interface.

Syntax

DellBMCSerialFlowControlType

Access

Read-only

BMC Serial Interface Bit Rate
Name

bmcSerialInterfaceBitRate

Object ID

1.3.6.1.4.1.674.10892.1.1900.20.1.11

Description

Defines the bit rate of the BMC serial interface.

Syntax

DellBMCSerialBitRateType

Access

Read-only

540

Baseboard Management Controller Group

Baseboard Management Controller LAN Interface Table
Name

bmcLANInterfaceTable

Object ID

1.3.6.1.4.1.674.10892.1.1900.30

Description

Defines the Baseboard Management Controller (BMC) LAN
Interface Table.

Syntax

SEQUENCE OF BmcLANInterfaceTableEntry

Access

Not accessible

BMC LAN Interface Table Entry
Name

bmcLANInterfaceTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.1900.30.1

Description

Defines the Baseboard Management Controller (BMC) LAN
Interface Table Entry.

Syntax

BmcLANInterfaceTableEntry

Access

Not accessible

Index

bmcLANInterfaceChassisIndex, bmcLANInterfaceBMCIndex,
bmcLANInterfaceIndex

BMC LAN Interface Chassis Index
Name

bmcLANInterfaceChassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.1900.30.1.1

Description

Defines the index (one-based) of the associated chassis.

Syntax

DellObjectRange

Access

Read-only

Baseboard Management Controller Group

541

BMC LAN Interface BMC Index
Name

bmcLANInterfaceBMCIndex

Object ID

1.3.6.1.4.1.674.10892.1.1900.30.1.2

Description

Defines the index (one-based) of the associated BMC.

Syntax

DellObjectRange

Access

Read-only

BMC LAN Interface Index
Name

bmcLANInterfaceIndex

Object ID

1.3.6.1.4.1.674.10892.1.1900.30.1.3

Description

Defines the index (one-based) of the BMC LAN interface.

Syntax

DellObjectRange

Access

Read-only

BMC LAN Interface State Capabilities
Name

bmcLANInterfaceStateCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.1900.30.1.4

Description

Defines the state capabilities of the BMC LAN interface.

Syntax

DellStateCapabilities

Access

Read-only

BMC LAN Interface State Settings
Name

bmcLANInterfaceStateSettings

Object ID

1.3.6.1.4.1.674.10892.1.1900.30.1.5

Description

Defines the state settings of the BMC LAN interface.

Syntax

DellStateSettings

Access

Read-write

542

Baseboard Management Controller Group

BMC LAN Interface Status
Name

bmcLANInterfaceStatus

Object ID

1.3.6.1.4.1.674.10892.1.1900.30.1.6

Description

Defines the status of the BMC LAN interface.

Syntax

DellStatus

Access

Read-only

BMC LAN Interface Channel Number
Name

bmcLANInterfaceChannelNumber

Object ID

1.3.6.1.4.1.674.10892.1.1900.30.1.7

Description

Defines the BMC channel number of the BMC LAN interface.

Syntax

DellUnsigned8BitRange

Access

Read-only

BMC LAN Interface IP Address Source
Name

bmcLANInterfaceIPAddressSource

Object ID

1.3.6.1.4.1.674.10892.1.1900.30.1.8

Description

Defines the source type of the IP address of the BMC LAN
interface.

Syntax

DellBMCLANIPAddressSourceType

Access

Read-only

BMC LAN Interface IP Address
Name

bmcLANInterfaceIPAddress

Object ID

1.3.6.1.4.1.674.10892.1.1900.30.1.9

Description

Defines the IP address of the BMC LAN interface.

Syntax

IpAddress

Access

Read-only

Baseboard Management Controller Group

543

BMC LAN Interface Subnet Mask Address
Name

bmcLANInterfaceSubnetMaskAddress

Object ID

1.3.6.1.4.1.674.10892.1.1900.30.1.10

Description

Defines the subnet mask of the BMC LAN interface.

Syntax

IpAddress

Access

Read-only

BMC LAN Interface Default Gateway Address
Name

bmcLANInterfaceDefaultGatewayAddress

Object ID

1.3.6.1.4.1.674.10892.1.1900.30.1.11

Description

Defines the IP address of the default gateway for the BMC LAN
interface.

Syntax

IpAddress

Access

Read-only

BMC LAN Interface MAC Address
Name

bmcLANInterfaceMACAddress

Object ID

1.3.6.1.4.1.674.10892.1.1900.30.1.12

Description

Defines the MAC address of the BMC LAN interface.

Syntax

DellMACAddress

Access

Read-only

BMC LAN Interface Alert Community Name
Name

bmcLANInterfaceAlertCommunityName

Object ID

1.3.6.1.4.1.674.10892.1.1900.30.1.13

Description

Defines the SNMP community used for BMC LAN alerts
(traps) sent on the BMC LAN interface.

Syntax

DisplayString (SIZE (0..32))

Access

Read-only

544

Baseboard Management Controller Group

Baseboard Management Controller Group
Variable Values
This section includes definitions for server administrator-specific variable
values used in this section.
Table 22-1.

BMC Serial Connection Mode Capabilities

Variable Name: DellBMCSerialConnectionModeCapabilities
Data Type: Integer
These values are bit masks; therefore, combination values are possible.
Possible Data Values

Meaning of Data Value

-- none(0)

No mode capabilities.

modemBasic(1)

BMC serial interface supports Modem Basic mode.

modemPPP(2)

BMC serial interface supports Modem Point to Point
Protocol (PPP) mode.

modemTerminal(4)

BMC serial interface supports Modem Terminal mode.

directBasic(8)

BMC serial interface supports Direct Basic mode.

directPPP(16)

BMC serial interface supports Direct PPP mode.

directTerminal(32)

BMC serial interface supports Direct Terminal mode.

Table 22-2.

BMC Serial Connection Mode Settings

Variable Name: DellBMCSerialConnectionModeSettings
Data Type: Integer
These values are bit masks; therefore, combination values are possible.
Possible Data Values

Meaning of Data Value

-- none(0)

No modes enabled.

modemBasic(1)

Modem Basic mode is enabled.

modemPPP(2)

Modem PPP mode is enabled.

modemTerminal(4)

Modem Terminal mode is enabled.

directBasic(8)

Direct Basic mode is enabled.

directPPP(16)

Direct PPP mode is enabled.

directTerminal(32)

Direct Terminal mode is enabled.
Baseboard Management Controller Group

545

Table 22-3. BMC Serial Flow Control Type
Variable Name: DellBMCSerialFlowControlType
Data Type: Integer
Possible Data Values

Meaning of Data Value

-- none(0)

No flow control used.

rtscts(1)

RTS/CTS (hardware) flow control used.

xonXoff(2)

XON/XOFF flow control used.

Table 22-4. BMC Serial Bit Rate Type
Variable Name: DellBMCSerialBitRateType
Data Type: Integer
Possible Data Values

Meaning of Data Value

bps9600(6)

Bit rate is 9600 bps (bits per second)

bps19200(7)

Bit rate is 19200 bps

bps38400(8)

Bit rate is 38400 bps

bps57600(9)

Bit rate is 57600 bps

bps115200(10)

Bit rate is 115200 bps

Table 22-5. BMC LAN IP Address Source Type
Variable Name: DellBMCLANIPAddressSourceType
Data Type: Integer
Possible Data Values

Meaning of Data Value

-- unspecified(0)

Source is unspecified.

static(1)

IP address is static.

dhcp(2)

Dynamic Host Configuration Protocol (DHCP)
used to obtain IP address.

biosOrSystemSoftware(3) BIOS or system software provided IP Address.
other(4)

546

Other protocol used to obtain IP address.

Baseboard Management Controller Group

Table 22-6.

BMC Management Controller Type

Variable Name: DellManagementControllerType
Data Type: Integer
Possible Data Values

Meaning of Data Value

-- legacyBMC(0)

Controller type is legacy Baseboard
Management Controller.

iDRAC(8)

Controller type is iDRAC.

iDRAC6(10)

Controller type is Integrated Dell Remote
Access Controller 6.

iDRAC6Modular(11)

Controller type is Integrated Dell Remote
Access Controller 6 (Modular).

iDRAC6BMC(13)

Controller type is Integrated Dell Remote
Access Controller 6 (BMC mode).

iDRAC7(16)

Controller type is Integrated Dell Remote
Access Controller 7.

iDRAC7Modular(17)

Controller type is Integrated Dell Remote
Access Controller 7 (Modular).

Baseboard Management Controller Group

547

548

Baseboard Management Controller Group

23

Field Replaceable Unit Group

A field replaceable unit (FRU) is a part that can be removed and replaced
without having to send the system to a repair facility. The Field Replaceable
Unit Group provides information about the field replaceable units that may
be present in your system.

Field Replaceable Unit Group Tables
The objects in the FRU group define information such as manufacturer,
serial number, part number and revision for field replaceable units.
The following MIB tables define the FRU group.

Field Replaceable Unit Table
Name

fruTable

Object ID

1.3.6.1.4.1.674.10892.1.2000.10

Description

Defines the Field Replaceable Unit table.

Syntax

SEQUENCE OF FruTableEntry

Access

Not accessible

FRU Table Entry
Name

fruTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.2000.10.1

Description

Defines the FRU Table Entry.

Syntax

FruTableEntry

Access

Not accessible

Index

fruChassisIndex, fruIndex

Field Replaceable Unit Group

549

FRU Chassis Index
Name

fruChassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.2000.10.1.1

Description

Defines the index (one-based) of the chassis containing the
FRU.

Syntax

DellObjectRange

Access

Read-only

FRU Index
Name

fruIndex

Object ID

1.3.6.1.4.1.674.10892.1.2000.10.1.2

Description

Defines the index (one-based) of the FRU.

Syntax

DellObjectRange

Access

Read-only

FRU Information Status
Name

fruInformationStatus

Object ID

1.3.6.1.4.1.674.10892.1.2000.10.1.3

Description

Defines the status of the FRU table entry.

Syntax

DellStatus

Access

Read-only

FRU Information State
Name

fruInformationState

Object ID

1.3.6.1.4.1.674.10892.1.2000.10.1.4

Description

Defines the state of the FRU information. Some information for
the FRU may not be available if the state is other than ok(1).

Syntax

DellFRUInformationState

Access

Read-only

550

Field Replaceable Unit Group

FRU Device Name
Name

fruDeviceName

Object ID

1.3.6.1.4.1.674.10892.1.2000.10.1.5

Description

Defines the device name of the FRU.

Syntax

DisplayString (SIZE (0..64))

Access

Read-only

FRU Manufacturer Name
Name

fruManufacturerName

Object ID

1.3.6.1.4.1.674.10892.1.2000.10.1.6

Description

Defines the manufacturer of the FRU.

Syntax

DisplayString (SIZE (0..64))

Access

Read-only

FRU Serial Number Name
Name

fruSerialNumberName

Object ID

1.3.6.1.4.1.674.10892.1.2000.10.1.7

Description

Defines the serial number of the FRU.

Syntax

DisplayString (SIZE (0..64))

Access

Read-only

FRU Part Number Name
Name

fruPartNumberName

Object ID

1.3.6.1.4.1.674.10892.1.2000.10.1.8

Description

Defines the part number of the FRU

Syntax

DisplayString (SIZE (0..64))

Access

Read-only

Field Replaceable Unit Group

551

FRU Revision Name
Name

fruRevisionName

Object ID

1.3.6.1.4.1.674.10892.1.2000.10.1.9

Description

Defines the revision of the FRU.

Syntax

DisplayString (SIZE (0..64))

Access

Read-only

FRU Manufacturing Date Name
Name

fruManufacturingDateName

Object ID

1.3.6.1.4.1.674.10892.1.2000.10.1.10

Description

Defines the manufacturing date of the FRU.

Syntax

DellDateName

Access

Read-only

FRU Asset Tag Name
Name

fruAssetTagName

Object ID

1.3.6.1.4.1.674.10892.1.2000.10.1.11

Description

Defines the asset tag of the FRU.

Syntax

DisplayString (SIZE (0..64))

Access

Read-only

552

Field Replaceable Unit Group

Field Replaceable Unit Group Variable Values
This section includes definitions for server administrator-specific variable
values.
Table 23-1.

FRU Information State

Variable Name: DellFRUInformationState
Data Type: Integer
Possible Data Values

Meaning of Data Value

ok(1)

FRU information is okay.

notSupported(2)

FRU information is not supported.

notAvailable(3)

FRU information is not available.

checksumInvalid(4)

FRU information checksum is invalid.

corrupted(5)

FRU information is corrupted.

Field Replaceable Unit Group

553

554

Field Replaceable Unit Group

Storage Management Group

24

The Storage Management Group is composed of the following:
•

Storage Management Group—information about the software product
and system status.

•

Storage Management Information Group—properties about the Simple
Network Management Protocol (SNMP) agent.

•

Global Data Group—system status.

•

Physical Devices Group—physical devices managed by the software.

•

Logical Devices Group—logical devices managed by the software.

•

Storage Management Event Group—SNMP traps.

Storage Management Group
The Storage Management Information Base (MIB) Group defines the
properties that identify information about the Storage Management software
product and the current status of the system it manages.
Software Version
Name

softwareVersion

Object ID

1.3.6.1.4.1.674.10893.1.20.1

Description

Identifies the version of the storage management component of
the systems management software.

Syntax

DisplayString

Access

Read-only

Storage Management Group

555

Global Status
Name

globalStatus

Object ID

1.3.6.1.4.1.674.10893.1.20.2

Description

Identifies the global health for the subsystem managed by the
Storage Management software. This global status is customized
for HP OpenView. Other applications should refer to the
agentSystemGlobalStatus entry in the globalData object group.
Possible values:
1: Critical
2: Warning
3: Normal
4: Unknown

Syntax

Integer

Access

Read-only

Software Manufacturer
Name

softwareManufacturer

Object ID

1.3.6.1.4.1.674.10893.1.20.3

Description

Identifies the manufacturer of the Storage Management software.

Syntax

DisplayString

Access

Read-only

Software Product
Name

softwareProduct

Object ID

1.3.6.1.4.1.674.10893.1.20.4

Description

Identifies product information for the Storage Management
software.

Syntax

DisplayString

Access

Read-only

556

Storage Management Group

Software Description
Name

softwareDescription

Object ID

1.3.6.1.4.1.674.10893.1.20.5

Description

Identifies the product description for the Storage Management
software.

Syntax

DisplayString

Access

Read-only

Storage Management Information Group
The Storage Management Information Group defines the properties that
identify the Storage Management software SNMP agent.
Display Name
Name

displayName

Object ID

1.3.6.1.4.1.674.10893.1.20.100.1

Description

Identifies the name of this management software for display
purposes.

Syntax

DisplayString

Access

Read-only

Description
Name

description

Object ID

1.3.6.1.4.1.674.10893.1.20.100.2

Description

Provides a short description of this management software.

Syntax

DisplayString

Access

Read-only

Storage Management Group

557

Agent Vendor
Name

agentVendor

Object ID

1.3.6.1.4.1.674.10893.1.20.100.3

Description

Identifies the name of the management software manufacturer.

Syntax

DisplayString

Access

Read-only

Agent Version
Name

agentVersion

Object ID

1.3.6.1.4.1.674.10893.1.20.100.4

Description

This entry is obsolete. Refer to softwareVersion.

Syntax

DisplayString

Access

Read-only

Global Data Group
The Global Data Management Information Base (MIB) Group defines the
properties that identify status information about the system that the Storage
Management software is managing and about the Storage Management
SNMP agent.
Agent System Global Status
Name

agentSystemGlobalStatus

Object ID

1.3.6.1.4.1.674.10893.1.20.110.1

Description

This entry is obsolete. Use the value agentGlobalSystemStatus.

Syntax

Integer

Access

Read-only

558

Storage Management Group

Agent Last Global Status
Name

agentLastGlobalStatus

Object ID

1.3.6.1.4.1.674.10893.1.20.110.2

Description

This entry is obsolete. Use the value
agentLastGlobalSystemStatus.

Syntax

Integer

Access

Read-only

Agent Time Stamp
Name

agentTimeStamp

Object ID

1.3.6.1.4.1.674.10893.1.20.110.3

Description

Identifies the last time the agent values have been updated.
Universal time in seconds since UTC 1/1/70.

Syntax

Integer

Access

Read-only

Agent Get Timeout
Name

agentGetTimeout

Object ID

1.3.6.1.4.1.674.10893.1.20.110.4

Description

Indicates the suggested timeout value, in milliseconds, for how
long the SNMP getter should wait while attempting to poll the
SNMP agent.

Syntax

Integer

Access

Read-only

Storage Management Group

559

Agent Modifiers
Name

agentModifiers

Object ID

1.3.6.1.4.1.674.10893.1.20.110.5

Description

Identifies the agent functional modifiers. When Agent Modifier is
set, the modifier is active. Bit definitions:
Bit 3: agent in debug mode.
All other bits are product specific.

Syntax

Integer

Access

Read-only

Agent Refresh Rate
Name

agentRefreshRate

Object ID

1.3.6.1.4.1.674.10893.1.20.110.6

Description

Identifies the rate, given in seconds, at which the cached data for
SNMP is refreshed. The default value is 300 seconds, or 5 minutes.

Syntax

Integer

Access

Read-only

Agent Hostname
Name

agentHostname

Object ID

1.3.6.1.4.1.674.10893.1.20.110.7

Description

This entry is obsolete for Storage Management.

Syntax

DisplayString

Access

Read-only

560

Storage Management Group

Agent IP Address
Name

agentIPAddress

Object ID

1.3.6.1.4.1.674.10893.1.20.110.8

Description

This entry is obsolete for Storage Management.

Syntax

DisplayString

Access

Read-only

Agent Software Status
Name

agentSoftwareStatus

Object ID

1.3.6.1.4.1.674.10893.1.20.110.9

Description

This entry is obsolete for Storage Management.

Syntax

DisplayString

Access

Read-only

Agent SNMP Version
Name

agentSnmpVersion

Object ID

1.3.6.1.4.1.674.10893.1.20.110.10

Description

This entry is obsolete. Refer to 0001 softwareVersion.

Syntax

DisplayString

Access

Read-only

Agent MIB Version
Name

agentMibVersion

Object ID

1.3.6.1.4.1.674.10893.1.20.110.11

Description

Identifies the version of the Storage Management MIB.

Syntax

DisplayString

Access

Read-only

Storage Management Group

561

Agent Management Software URL Name
Name

agentManagementSoftwareURLName

Object ID

1.3.6.1.4.1.674.10893.1.20.110.12

Description

Identifies the Universal Resource Locator (URL) of the systems
management software.

Syntax

DisplayString

Access

Read-only

Agent Global System Status
Name

agentGlobalSystemStatus

Object ID

1.3.6.1.4.1.674.10893.1.20.110.13

Description

Identifies the global health information for the subsystem
managed by the Storage Management software. This is a rollup for
the entire agent including any monitored devices. The status is
intended to give initiative to an SNMP monitor to get further data
when this status is abnormal. Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable

NOTE: This global status should be used by applications other
than HP OpenView. HP OpenView should refer to the
globalStatus in the root level object group.

Syntax

DellStatus

Access

Read-only

562

Storage Management Group

Agent Last Global System Status
Name

agentLastGlobalSystemStatus

Object ID

1.3.6.1.4.1.674.10893.1.20.110.14

Description

Identifies the previous global status of the system managed by the
Storage Management software. Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable

Syntax

DellStatus

Access

Read-only

Agent Smart Thermal Shutdown
Name

agentSmartThermalShutdown

Object ID

1.3.6.1.4.1.674.10893.1.20.110.15

Description

Indicates the status of smart thermal shutdown for PowerVault
220S and PowerVault 221S enclosures.
Possible values:
1: Enabled
2: Disabled
3: Not applicable

Syntax

Integer

Access

Read-only

Storage Management Group

563

Physical Devices Group
The Physical Devices MIB group provides information about the devices
managed by the Storage Management software and their relationships to each
other. The following MIB tables define objects and relationships
(connections) among the objects.

564

•

Controller Table—describes available properties for each controller on the
managed system.

•

Channel Table—describes available properties for each channel on the
managed system.

•

Enclosure Table—describes available properties for each enclosure on the
managed system.

•

Array Disk Table—describes available properties for each physical array
disk on the managed system.

•

Array Disk Enclosure Connection Table—describes the connections
between Fibre Channel array disks, their enclosure, and their associated
controller. For each object in the table, its object number corresponds to an
instance number in the appropriate MIB table for that object where all of
the object properties can be found.

•

Array Disk Channel Connection Table—describes the connections
between SCSI array disks, their channel, and their associated controller.
For each object in the table, its object number corresponds to an instance
number in the appropriate MIB table for that object where all of the object
properties can be found.

•

Fan Table—describes available properties for each fan on the managed
system.

•

Fan Connection Table—describes the connection between each fan on
the managed system and its enclosure. Each enclosure number in the table
corresponds to that enclosure instance in the Enclosure Table.

•

Power Supply Table—describes available properties for each power supply
on the managed system.

•

Power Supply Connection Table—describes the connection between each
power supply on the managed system and its enclosure. Each enclosure
number in the table corresponds to that enclosure instance in the
Enclosure Table.

Storage Management Group

•

Temperature Probe Table—describes available properties for each
temperature probe on the managed system.

•

Temperature Probe Connection Table—describes the connection
between each temperature probe on the managed system and its
enclosure. Each enclosure number in the table corresponds to that
enclosure instance in the Enclosure Table.

•

EMM Table—describes available properties for each Enclosure
Management Module (EMM) on the managed system.

•

EMM Connection Table—describes the connection between each EMM
on the managed system and its enclosure. Each enclosure number in the
table corresponds to that enclosure instance in the Enclosure Table.

•

Battery Table—describes available properties for each controller battery on
the managed system.

•

Battery Connection Table—describes the connection between each
battery on the managed system and its controller. Each controller number
in the table corresponds to that controller instance in the Controller Table.

Controller Table
This table describes available properties for each controller on the managed
system.
The following object sets up the Controller Table.
Name

controllerTable

Object ID

1.3.6.1.4.1.674.10893.1.20.130.1

Description

Defines the controller table, which is a table of managed
Redundant Array of Independent disks (RAID) controllers. The
number of entries is related to the number of RAID controllers
discovered by the system.

Syntax

SEQUENCE OF ControllerEntry

Access

Not accessible

Storage Management Group

565

Controller Entry
Name

controllerEntry

Object ID

1.3.6.1.4.1.674.10893.1.20.130.1.1

Description

Defines the controller table entry, which is an entry in the table of
RAID controllers.

Syntax

ControllerEntry

Access

Not accessible

Index

controllerNumber

Controller Number
Name

controllerNumber

Object ID

1.3.6.1.4.1.674.10893.1.20.130.1.1.1

Description

Identifies the instance number of the controller entry.

Syntax

Integer

Access

Read-only

Controller Name
Name

controllerName

Object ID

1.3.6.1.4.1.674.10893.1.20.130.1.1.2

Description

Identifies the name of the controller in this subsystem as
represented in Storage Management. Includes the controller type
and instance. For example: PERC 3/QC 1.

Syntax

DisplayString

Access

Read-only

566

Storage Management Group

Controller Vendor
Name

controllerVendor

Object ID

1.3.6.1.4.1.674.10893.1.20.130.1.1.3

Description

Identifies the controller's vendor's name.

Syntax

DisplayString

Access

Read-only

Controller Type
Name

controllerType

Object ID

1.3.6.1.4.1.674.10893.1.20.130.1.1.4

Description

Identifies the type of controller:
1: SCSI
2: PowerVault 660F
3: Power Vault 662F
4: Integrated/Intelligent Drive Electronics (IDE)
5: Serial Advanced Technology Architecture (SATA)
6: Serial Attached SCSI (SAS)
9: PCIe SSD

Syntax

Integer

Access

Read-only

Controller State
Name

controllerState

Object ID

1.3.6.1.4.1.674.10893.1.20.130.1.1.5

Storage Management Group

567

Name

controllerState

Description

Identifies the status of the controller's subsystem (which includes
any devices connected to it). Possible states:
0: Unknown
1: Ready
2: Failed
3: Online
4: Offline
6: Degraded

Syntax

Integer

Access

Read-only

Controller Severity
Name

controllerSeverity

Object ID

1.3.6.1.4.1.674.10893.1.20.130.1.1.6

Description

This entry is obsolete for Storage Management. It was replaced
with RollUpStatus and ComponentStatus for each device.

Syntax

Integer

Access

Read-only

Controller Rebuild Rate in Percent
Name

controllerRebuildRateInPercent

Object ID

1.3.6.1.4.1.674.10893.1.20.130.1.1.7

Description

Identifies the percent of the compute cycles dedicated to
rebuilding failed array disks.

Syntax

Integer

Access

Read-only

568

Storage Management Group

Controller Firmware Version
Name

controllerFWVersion

Object ID

1.3.6.1.4.1.674.10893.1.20.130.1.1.8

Description

Identifies the controller's current firmware version.

Syntax

DisplayString

Access

Read-only

Controller Cache Size in Megabytes
Name

controllerCacheSizeInMB

Object ID

1.3.6.1.4.1.674.10893.1.20.130.1.1.9

Description

Identifies the controller's current amount of cache memory in
megabytes. If this size is 0, the cache memory is less than a
megabyte.

Syntax

Integer

Access

Read-only

Controller Cache Size in Bytes
Name

controllerCacheSizeInBytes

Object ID

1.3.6.1.4.1.674.10893.1.20.130.1.1.10

Description

Identifies the controller's current amount of cache memory that is
less than a megabyte. This combined with the
controllerCacheSizeInMB is the total amount of memory.

Syntax

Integer

Access

Read-only

Controller Physical Device Count
Name

controllerPhysicalDeviceCount

Object ID

1.3.6.1.4.1.674.10893.1.20.130.1.1.11

Description

Identifies the number of physical devices on the controller
channel including both disks and the controller.

Syntax

Integer

Storage Management Group

569

Name

controllerPhysicalDeviceCount

Access

Read-only

Controller Logical Device Count
Name

controllerLogicalDeviceCount

Object ID

1.3.6.1.4.1.674.10893.1.20.130.1.1.12

Description

Identifies the number of virtual disks on the controller.

Syntax

Integer

Access

Read-only

Controller Partner Status
Name

controllerPartnerStatus

Object ID

1.3.6.1.4.1.674.10893.1.20.130.1.1.13

Description

This entry is obsolete for Storage Management.

Syntax

DisplayString

Access

Read-only

Controller Host Port Count
Name

controllerHostPortCount

Object ID

1.3.6.1.4.1.674.10893.1.20.130.1.1.14

Description

This entry is obsolete. Fibre channel is not supported in Storage
Management.

Syntax

Integer

Access

Read-only

Controller Memory Size in Megabytes
Name

controllerMemorySizeInMB

Object ID

1.3.6.1.4.1.674.10893.1.20.130.1.1.15

570

Storage Management Group

Name

controllerMemorySizeInMB

Description

Identifies the size of memory in megabytes on the controller. If
this size is 0, it is less than a megabyte.

NOTE: This attribute is only supported on Adaptec controllers.
Syntax

Integer

Access

Read-only

Controller Memory Size in Bytes
Name

controllerMemorySizeInBytes

Object ID

1.3.6.1.4.1.674.10893.1.20.130.1.1.16

Description

Identifies the size of memory on the controller that is less than a
megabyte. This combined with the controllerMemorySizeInMB is
the total size of the memory.

NOTE: This attribute is only supported on Adaptec controllers.
Syntax

Integer

Access

Read-only

Controller Drive Channel Count
Name

controllerDriveChannelCount

Object ID

1.3.6.1.4.1.674.10893.1.20.130.1.1.17

Description

This entry is obsolete. Fibre channel is not supported in Storage
Management.

Syntax

Integer

Access

Read-only

Controller Fault Tolerant
Name

controllerFaultTolerant

Object ID

1.3.6.1.4.1.674.10893.1.20.130.1.1.18

Description

This entry is obsolete. Fibre channel is not supported in Storage
Management.

Syntax

Integer
Storage Management Group

571

Name

controllerFaultTolerant

Access

Read-only

Controller C0 Port 0 World Wide Name
Name

controllerC0Port0WorldWideName

Object ID

1.3.6.1.4.1.674.10893.1.20.130.1.1.19

Description

This entry is obsolete. Fibre channel is not supported in Storage
Management.

Syntax

DisplayString

Access

Read-only

Controller C0 Port 0 Name
Name

controllerC0Port0Name

Object ID

1.3.6.1.4.1.674.10893.1.20.130.1.1.20

Description

This entry is obsolete. Fibre channel is not supported in Storage
Management.

Syntax

DisplayString

Access

Read-only

Controller C0 Port 0 ID
Name

controllerC0Port0ID

Object ID

1.3.6.1.4.1.674.10893.1.20.130.1.1.21

Description

This entry is obsolete. Fibre channel is not supported in Storage
Management.

Syntax

Integer

Access

Read-only

Controller C0 Target
Name

controllerC0Target

Object ID

1.3.6.1.4.1.674.10893.1.20.130.1.1.22

572

Storage Management Group

Name

controllerC0Target

Description

This entry is obsolete. Fibre channel is not supported in Storage
Management.

Syntax

Integer

Access

Read-only

Controller C0 Channel
Name

controllerC0Channel

Object ID

1.3.6.1.4.1.674.10893.1.20.130.1.1.23

Description

This entry is obsolete. Fibre channel is not supported in Storage
Management.

Syntax

Integer

Access

Read-only

Controller C0 Operating System Controller
Name

controllerC0OSController

Object ID

1.3.6.1.4.1.674.10893.1.20.130.1.1.24

Description

This entry is obsolete. Fibre channel is not supported in Storage
Management.

Syntax

DisplayString

Access

Read-only

Controller C0 Battery State
Name

controllerC0BatteryState

Object ID

1.3.6.1.4.1.674.10893.1.20.130.1.1.25

Description

This entry is obsolete. Fibre channel is not supported in Storage
Management.

Syntax

Integer

Access

Read-only

Storage Management Group

573

Controller C1 Port 0 World Wide Name
Name

controllerC1Port0WWN

Object ID

1.3.6.1.4.1.674.10893.1.20.130.1.1.26

Description

This entry is obsolete. Fibre channel is not supported in Storage
Management.

Syntax

DisplayString

Access

Read-only

Controller C1 Port 0 Name
Name

controllerC1Port0Name

Object ID

1.3.6.1.4.1.674.10893.1.20.130.1.1.27

Description

This entry is obsolete. Fibre channel is not supported in Storage
Management.

Syntax

DisplayString

Access

Read-only

Controller C1 Port 0 ID
Name

controllerC1Port0ID

Object ID

1.3.6.1.4.1.674.10893.1.20.130.1.1.28

Description

This entry is obsolete. Fibre channel is not supported in Storage
Management.

Syntax

Integer

Access

Read-only

Controller C1 Target
Name

controllerC1Target

Object ID

1.3.6.1.4.1.674.10893.1.20.130.1.1.29

Description

This entry is obsolete. Fibre channel is not supported in Storage
Management.

Syntax

Integer

Access

Read-only

574

Storage Management Group

Controller C1 Channel
Name

controllerC1Channel

Object ID

1.3.6.1.4.1.674.10893.1.20.130.1.1.30

Description

This entry is obsolete. Fibre channel is not supported in Storage
Management.

Syntax

Integer

Access

Read-only

Controller C1 Operating System Controller
Name

controllerC1OSController

Object ID

1.3.6.1.4.1.674.10893.1.20.130.1.1.31

Description

This entry is obsolete. Fibre channel is not supported in Storage
Management.

Syntax

DisplayString

Access

Read-only

Controller Battery State C1
Name

controllerC1BatteryState

Object ID

1.3.6.1.4.1.674.10893.1.20.130.1.1.32

Description

This entry is obsolete. Fibre channel is not supported in Storage
Management.

Syntax

Integer

Access

Read-only

Controller Node World Wide Name
Name

controllerNodeWWN

Object ID

1.3.6.1.4.1.674.10893.1.20.130.1.1.33

Description

This entry is obsolete. Fibre channel is not supported in Storage
Management.

Syntax

DisplayString

Access

Read-only

Storage Management Group

575

Controller C0 Port 1 World Wide Name
Name

controllerC0Port1WWN

Object ID

1.3.6.1.4.1.674.10893.1.20.130.1.1.34

Description

This entry is obsolete. Fibre channel is not supported in Storage
Management.

Syntax

DisplayString

Access

Read-only

Controller C1 Port 1 World Wide Name
Name

controllerC1Port1WWN

Object ID

1.3.6.1.4.1.674.10893.1.20.130.1.1.35

Description

This entry is obsolete. Fibre channel is not supported in Storage
Management.

Syntax

DisplayString

Access

Read-only

Controller Battery Charge Count
Name

controllerBatteryChargeCount

Object ID

1.3.6.1.4.1.674.10893.1.20.130.1.1.36

Description

This entry is obsolete. Fibre channel is not supported in Storage
Management.

Syntax

Integer

Access

Read-only

Controller Roll-Up Status
Name

controllerRollUpStatus

Object ID

1.3.6.1.4.1.674.10893.1.20.130.1.1.37

576

Storage Management Group

Name

controllerRollUpStatus

Description

Indicates severity of the controller state. This is the combined
status of the controller and its components. Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable

Syntax

DellStatus

Access

Read-only

Controller Component Status
Name

controllerComponentStatus

Object ID

1.3.6.1.4.1.674.10893.1.20.130.1.1.38

Description

Indicates the status of the controller itself without the propagation
of any contained component status. Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable

Syntax

DellStatus

Access

Read-only

Controller Nexus ID
Name

controllerNexusID

Object ID

1.3.6.1.4.1.674.10893.1.20.130.1.1.39

Description

Displays the durable unique ID for this controller.

Syntax

DisplayString
Storage Management Group

577

Name

controllerNexusID

Access

Read-only

Controller Alarm State
Name

controllerAlarmState

Object ID

1.3.6.1.4.1.674.10893.1.20.130.1.1.40

Description

Indicates the state or setting for the controller's alarm. Possible
values:
1: Enabled
2: Disabled
3: Not Applicable

Syntax

Integer

Access

Read-only

Controller Driver Version
Name

controllerDriverVersion

Object ID

1.3.6.1.4.1.674.10893.1.20.130.1.1.41

Description

Indicates the currently installed driver version of the controller.

Syntax

DisplayString

Access

Read-only

Controller PCI Slot
Name

controllerPCISlot

Object ID

1.3.6.1.4.1.674.10893.1.20.130.1.1.42

Description

Indicates the PCI slot number or embedded number for
controllers on the motherboard.

Syntax

DisplayString

Access

Read-only

578

Storage Management Group

Controller Cluster Mode
Name

controllerClusterMode

Object ID

1.3.6.1.4.1.674.10893.1.20.130.1.1.43

Description

Identifies if the controller is in cluster mode.
Possible values:
1: Enabled
2: Disabled
3: Active (enabled and active)
99: Not Applicable

Syntax

Integer

Access

Read-only

Controller Minimum Firmware Version
Name

controllerMinFWVersion

Object ID

1.3.6.1.4.1.674.10893.1.20.130.1.1.44

Description

The minimum firmware version for Storage Management to
support the controller.

Syntax

DisplayString

Access

Read-only

Controller Minimum Driver Version
Name

controllerMinDriverVersion

Object ID

1.3.6.1.4.1.674.10893.1.20.130.1.1.45

Description

The minimum driver version for Storage Management to support
the controller.

Syntax

DisplayString

Access

Read-write

Storage Management Group

579

Controller SCSI Initiator ID
Name

controllerSCSIInitiatorID

Object ID

1.3.6.1.4.1.674.10893.1.20.130.1.1.46

Description

Displays the SCSI ID of the initiator.

Syntax

Integer

Access

Read-only

Controller Channel Count
Name

controllerChannelCount

Object ID

1.3.6.1.4.1.674.10893.1.20.130.1.1.47

Description

Displays the number of channels on the controller.

Syntax

Integer

Access

Read-only

Controller Reconstruct Rate
Name

controllerReconstructRate

Object ID

1.3.6.1.4.1.674.10893.1.20.130.1.1.48

Description

Displays the rate for reconstruct on the controller.

Syntax

Integer

Access

Read-write

Controller Patrol Read Rate
Name

controllerPatrolReadRate

Object ID

1.3.6.1.4.1.674.10893.1.20.130.1.1.49

Description

Displays the rate for patrol read on the controller.

Syntax

Integer

Access

Read-only

580

Storage Management Group

Controller BGI Rate
Name

controllerBGIRate

Object ID

1.3.6.1.4.1.674.10893.1.20.130.1.1.50

Description

Displays the rate for background initialization on the controller.

Syntax

Integer

Access

Read-only

Controller Check Consistency Rate
Name

controllerCheckConsistencyRate

Object ID

1.3.6.1.4.1.674.10893.1.20.130.1.1.51

Description

Displays the rate for check consistency on the controller.

Syntax

Integer

Access

Read-only

Controller Patrol Read Mode
Name

controllerPatrolReadMode

Object ID

1.3.6.1.4.1.674.10893.1.20.130.1.1.52

Description

Identifies the patrol read mode.
Possible values:
1: Automatic (enabled)
2: Manual (enabled)
3: Disabled

Syntax

Integer

Access

Read-only

Controller Patrol Read State
Name

controllerPatrolReadState

Object ID

1.3.6.1.4.1.674.10893.1.20.130.1.1.53

Storage Management Group

581

Name

controllerPatrolReadState

Description

Displays the state of the patrol read.
Possible values:
1: Stopped - not running
2: Ready - ready to start
4: Active - is running
8: Aborted - has aborted

Syntax

Integer

Access

Read-only

Controller Patrol Read Iterations
Name

controllerPatrolReadIterations

Object ID

1.3.6.1.4.1.674.10893.1.20.130.1.1.54

Description

Displays the number of times Patrol Read has been run on this
controller.

Syntax

Integer

Access

Read-only

Controller Storport Driver Version
Name

controllerStorportDriverVersion

Object ID

1.3.6.1.4.1.674.10893.1.20.130.1.1.55

Description

Provides current Windows OS storport driver version.

NOTE: Not applicable for Linux.
Syntax

Octet String

Access

Read-only

582

Storage Management Group

Controller Minimum Required Storport Version
Name

controllerMinimumRequiredStorportVersion

Object ID

1.3.6.1.4.1.674.10893.1.20.130.1.1.56

Description

Provides minimum required storport driver version for Windows
OS only.

NOTE: Not applicable for Linux.
Syntax

Octet String

Access

Read-only

Controller Encryption Capable
Name

controllerEncryptionCapable

Object ID

1.3.6.1.4.1.674.10893.1.20.130.1.1.57

Description

Indicates the encryption capability of the controller.
Possiable Values:
1 - Capable
99 - Not Applicable

Syntax

Integer

Access

Read-only

Controller Encryption Key Present
Name

controllerEncryptionKeyPresent

Object ID

1.3.6.1.4.1.674.10893.1.20.130.1.1.58

Description

Indicates presence of encryption key for the controller.
Possiable Values:
1 - Yes
0 - No
99 - Not Applicable

Syntax

Integer

Access

Read-only

Storage Management Group

583

Controller Persistent Hot Spare
Name

controllerPersistentHotSpare

Object ID

1.3.6.1.4.1.674.10893.1.20.130.1.1.59

Description

Indicates the Persistent Hot Spare capability of the controller.
Possiable Values:
1 - Enabled
0 - Disabled
99 - Undetermined / Not applicable

Syntax

Integer

Access

Read-only

Controller Spin Down Unconfigured Drives
Name

controllerSpinDownUnconfiguredDrives

Object ID

1.3.6.1.4.1.674.10893.1.20.130.1.1.60

Description

Indicates controller capability to move unconfigured drives to
power save mode.
Possiable Values:
1 - Enabled
0 - Disabled
99 - Undetermined / Not applicable

Syntax

Integer

Access

Read-only

Controller Spin Down Hot Spare Drives
Name

controllerSpinDownHotSpareDrives

Object ID

1.3.6.1.4.1.674.10893.1.20.130.1.1.61

Description

Indicates controller capability to move hot spare drives to power
save mode.
Possiable Values:
1 - Enabled
0 - Disabled
99 - Undetermined / Not applicable

584

Storage Management Group

Name

controllerSpinDownHotSpareDrives

Syntax

Integer

Access

Read-only

Storage Management Group

585

Controller Spin Down Time Interval
Name

controllerSpinDownTimeInterval

Object ID

1.3.6.1.4.1.674.10893.1.20.130.1.1.62

Description

Shows the duration in minutes after which, the unconfigured or
hot spare drives is spun down to power save mode.
Possiable Values: 30 to 1440

NOTE: A value of 9999 indicates that the feature is not available.
Syntax

Integer

Access

Read-write

Controller Encryption Mode
Name

controllerEncryptionMode

Object ID

1.3.6.1.4.1.674.10893.1.20.130.1.1.63

Description

Indicates the current encryption mode of the controller.
Possiable Values:
0 - No Encryption
1 - Local Key Management (LKM)
2 - Dell Key Management (DKM)
99 - Not Applicable

Syntax

Integer

Access

Read-only

Controller CacheCade
Name

controllerCacheCade

Object ID

1.3.6.1.4.1.674.10893.1.20.130.1.1.64

Description

Indicates if the controller is CacheCade capable or not.
Possiable Values:
1 - Capable
0 - Not Capable
99 - Undetermined

Syntax

Integer

Access

Read-only

586

Storage Management Group

Controller Spin Down Configured Drives
Name

controllerSpinDownConfiguredDrives

Object ID

1.3.6.1.4.1.674.10893.1.20.130.1.1.65

Description

Indicates the controller capability to spin down configured
physical disks.
Possiable Values:
0 - Disabled
1 - Enabled
99 - Undetermined

Syntax

Integer

Access

Read-only

Controller Automatic Power Saving
Name

controllerAutomaticPowerSaving

Object ID

1.3.6.1.4.1.674.10893.1.20.130.1.1.66

Description

Indicates the controller capability for automatic power saving.
Possiable Values:
0 - Disabled
1 - Enabled
99 - Undetermined

Syntax

Integer

Access

Read-only

Controller Configured Drives SpinUp Time
Name

controllerConfiguredDrivesSpinUpTime

Object ID

1.3.6.1.4.1.674.10893.1.20.130.1.1.67

Description

Indicates the configured drives spin up start time.
Possiable Values:
1:00 AM to 12:59 PM
9999 - Undetermined

Syntax

DisplayString

Storage Management Group

587

Name

controllerConfiguredDrivesSpinUpTime

Access

Read-only

Controller Configured Drives SpinUp TimeInterval
Name

controllerConfiguredDrivesSpinUpTimeInterval

Object ID

1.3.6.1.4.1.674.10893.1.20.130.1.1.68

Description

Indicates the configured drives spin up time interval in hours.
This value is added with the configured drives at start time to
arrive at time window in which configured drives are always spin
up.
Possiable Values: 1 .. 24, 9999 - Undetermined

Syntax

Integer

Access

Read-only

Controller Preserved Cache
Name

controllerPreservedCache

Object ID

1.3.6.1.4.1.674.10893.1.20.130.1.1.69

Description

Indicates if the preserved cache is present on the controller.
Possiable Values:
1- Yes
0 - No
99 - Not available / Not applicable

Syntax

Integer

Access

Read-only

588

Storage Management Group

Channel Table
This section describes available properties for each channel on the managed
system.
The following object sets up the Channel Table.
Name

channelTable

Object ID

1.3.6.1.4.1.674.10893.1.20.130.2

Description

Defines the channel table.

Syntax

SEQUENCE OF ChannelEntry

Access

Not accessible

Channel Entry
Name

channelEntry

Object ID

1.3.6.1.4.1.674.10893.1.20.130.2.1

Description

Defines the channel table entry.

Syntax

ChannelEntry

Access

Not accessible

Index:

channelNumber

Channel Number
Name

channelNumber

Object ID

1.3.6.1.4.1.674.10893.1.20.130.2.1.1

Description

Identifies the instance number of the channel entry.

Syntax

Integer

Access

Read-only

Channel Name
Name

channelName

Object ID

1.3.6.1.4.1.674.10893.1.20.130.2.1.2

Storage Management Group

589

Name

channelName

Description

Identifies the name of the channel as represented in Storage
Management. The name includes the word channel and the
instance. For example: Channel 1.

Syntax

DisplayString

Access

Read-only

Channel State
Name

channelState

Object ID

1.3.6.1.4.1.674.10893.1.20.130.2.1.3

Description

Identifies the current state of the channel. Possible states:
0: Unknown
1: Ready - The I/O has resumed
2: Failed
3: Online
4: Offline - The I/O has paused
6: Degraded

Syntax

Integer

Access

Read-only

Channel Severity
Name

channelSeverity

Object ID

1.3.6.1.4.1.674.10893.1.20.130.2.1.4

Description

This entry is obsolete for Storage Management. It is replaced with
RollUpStatus and ComponentStatus for each device.

Syntax

Integer

Access

Read-only

590

Storage Management Group

Channel Termination
Name

channelTermination

Object ID

1.3.6.1.4.1.674.10893.1.20.130.2.1.5

Description

Identifies the type of SCSI termination on the channel.
Termination is required for proper operation of the channel.
Possible values:
1: Wide Termination (16 bit)
2: Narrow Termination (8 bit)
3: Not Terminated

Syntax

Integer

Access

Read-only

Channel SCSI ID
Name

channelSCSIID

Object ID

1.3.6.1.4.1.674.10893.1.20.130.2.1.6

Description

Identifies the SCSI ID of the controller to which the channel
belongs.

Syntax

Integer

Access

Read-only

Storage Management Group

591

Channel Roll-Up Status
Name

channelRollUpStatus

Object ID

1.3.6.1.4.1.674.10893.1.20.130.2.1.7

Description

Identifies the severity of the channel state. This is the combined
status of the channel and its components. Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable

Syntax

DellStatus

Access

Read-only

Channel Component Status
Name

channelComponentStatus

Object ID

1.3.6.1.4.1.674.10893.1.20.130.2.1.8

Description

The status of the channel itself without the propagation of any
contained component status. Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable

Syntax

DellStatus

Access

Read-only

592

Storage Management Group

Channel Nexus ID
Name

channelNexusID

Object ID

1.3.6.1.4.1.674.10893.1.20.130.2.1.9

Description

Displays the durable unique ID for the channel.

Syntax

DisplayString

Access

Read-only

Channel Data Rate
Name

channelDataRate

Object ID

1.3.6.1.4.1.674.10893.1.20.130.2.1.10

Description

Identifies the data rate of the channel.

Syntax

DisplayString

Access

Read-only

Channel Bus Type
Name

channelBusType

Object ID

1.3.6.1.4.1.674.10893.1.20.130.2.1.11

Description

Identifies the bus type of the channel. Possible values:
1: SCSI
2: IDE
3: Fibre Channel
4: Serial Storage Architecture (SSA)
6: Universal Serial Bus (USB)
7: SATA
8: SAS
9: PCIe

Syntax

Integer

Access

Read-only

Storage Management Group

593

Enclosure Table
This section describes available properties for each enclosure on the managed
system.
The following object sets up the Enclosure Table.
Name

enclosureTable

Object ID

1.3.6.1.4.1.674.10893.1.20.130.3

Description

Defines the enclosure table.

Syntax

SEQUENCE OF EnclosureEntry

Access

Not accessible

Enclosure Entry
Name

enclosureEntry

Object ID

1.3.6.1.4.1.674.10893.1.20.130.3.1

Description

Defines the enclosure table entry.

Syntax

EnclosureEntry

Access

Not accessible

Index

enclosureNumber

Enclosure Number
Name

enclosureNumber

Object ID

1.3.6.1.4.1.674.10893.1.20.130.3.1.1

Description

Identifies the instance number of the enclosure entry.

Syntax

Integer

Access

Read-only

594

Storage Management Group

Enclosure Name
Name

enclosureName

Object ID

1.3.6.1.4.1.674.10893.1.20.130.3.1.2

Description

Identifies the enclosure's name as represented in Storage
Management.

Syntax

DisplayString

Access

Read-only

Enclosure Vendor
Name

enclosureVendor

Object ID

1.3.6.1.4.1.674.10893.1.20.130.3.1.3

Description

Identifies the enclosure's (re)seller's name.

Syntax

DisplayString

Access

Read-only

Enclosure State
Name

enclosureState

Object ID

1.3.6.1.4.1.674.10893.1.20.130.3.1.4

Description

Identifies the current condition of the enclosure (which includes any
devices connected to it.) Possible values:
0: Unknown
1: Ready
2: Failed
3: Online
4: Offline
6: Degraded

Syntax

Integer

Access

Read-only

Storage Management Group

595

Enclosure Severity
Name

enclosureSeverity

Object ID

1.3.6.1.4.1.674.10893.1.20.130.3.1.5

Description

This entry is obsolete for Storage Management. It is replaced with
RollUpStatus and ComponentStatus for each device.

Syntax

Integer

Access

Read-only

Enclosure ID
Name

enclosureID

Object ID

1.3.6.1.4.1.674.10893.1.20.130.3.1.6

Description

Represents the unique id for an enclosure.

Syntax

DisplayString

Access

Read-only

Enclosure Processor Version
Name

enclosureProcessorVersion

Object ID

1.3.6.1.4.1.674.10893.1.20.130.3.1.7

Description

This entry is obsolete for Storage Management.

Syntax

DisplayString

Access

Read-only

Enclosure Service Tag
Name

enclosureServiceTag

Object ID

1.3.6.1.4.1.674.10893.1.20.130.3.1.8

Description

Displays the enclosure identification used when consulting
customer support.

Syntax

DisplayString

Access

Read-only

596

Storage Management Group

Enclosure Asset Tag
Name

enclosureAssetTag

Object ID

1.3.6.1.4.1.674.10893.1.20.130.3.1.9

Description

Displays the customer definable asset tag for the enclosure.

Syntax

DisplayString

Access

Read-only

Enclosure Asset Name
Name

enclosureAssetName

Object ID

1.3.6.1.4.1.674.10893.1.20.130.3.1.10

Description

Displays the customer definable asset name of the enclosure.

Syntax

DisplayString

Access

Read-only

Enclosure Split Bus Part Number
Name

enclosureSplitBusPartNumber

Object ID

1.3.6.1.4.1.674.10893.1.20.130.3.1.11

Description

Identifies the enclosure's split bus part number.

Syntax

DisplayString

Access

Read-only

Enclosure Product ID
Name

enclosureProductID

Object ID

1.3.6.1.4.1.674.10893.1.20.130.3.1.12

Description

Displays the enclosure's product identification. This also
corresponds to the enclosure type.

Syntax

DisplayString

Access

Read-only

Storage Management Group

597

Enclosure Kernel Version
Name

enclosureKernelVersion

Object ID

1.3.6.1.4.1.674.10893.1.20.130.3.1.13

Description

This entry is obsolete for Storage Management.

Syntax

DisplayString

Access

Read-only

Enclosure ESM1 Part Number
Name

enclosureESM1PartNumber

Object ID

1.3.6.1.4.1.674.10893.1.20.130.3.1.14

Description

This entry is obsolete for Storage Management.

Syntax

DisplayString

Access

Read-only

Enclosure ESM2 Part Number
Name

enclosureESM2PartNumber

Object ID

1.3.6.1.4.1.674.10893.1.20.130.3.1.15

Description

This entry is obsolete for Storage Management.

Syntax

DisplayString

Access

Read-only

598

Storage Management Group

Enclosure Type
Name

enclosureType

Object ID

1.3.6.1.4.1.674.10893.1.20.130.3.1.16

Description

Indicates the type of the enclosure. Possible values:
1: Internal
2: Dell PowerVault 200S (PowerVault 201S)
3: Dell PowerVault 210S (PowerVault 211S)
4: Dell PowerVault 220S (PowerVault 221S)
5: Dell PowerVault 660F
6: Dell PowerVault 224F
7: Dell PowerVault 660F/PowerVault 224F
8: Dell MD1000
9: Dell MD1120

Syntax

DisplayString

Access

Read-only

Enclosure Processor2 Version
Name

enclosureProcessor2Version

Object ID

1.3.6.1.4.1.674.10893.1.20.130.3.1.17

Description

This entry is obsolete for Storage Management.

Syntax

DisplayString

Access

Read-only

Storage Management Group

599

Enclosure Configuration
Name

enclosureConfig

Object ID

1.3.6.1.4.1.674.10893.1.20.130.3.1.18

Description

Identifies the current configuration of the enclosure's backplane.
Possible values:
1: Joined
2: Split Bus
3: Clustered
4: Unified

Syntax

Integer

Access

Read-only

Enclosure Channel Number
Name

enclosureChannelNumber

Object ID

1.3.6.1.4.1.674.10893.1.20.130.3.1.19

Description

Identifies the channel number, or bus, to which the enclosure is
connected.

Syntax

Integer

Access

Read-only

Enclosure Alarm
Name

enclosureAlarm

Object ID

1.3.6.1.4.1.674.10893.1.20.130.3.1.20

Description

Identifies the current status of the enclosure's alarm (PowerVault
220S and PowerVault 221S only.) Possible values:
1: Disabled
2: Enabled

Syntax

Integer

Access

Read-only

600

Storage Management Group

Enclosure Backplane Part Number
Name

enclosureBackplanePartNumber

Object ID

1.3.6.1.4.1.674.10893.1.20.130.3.1.21

Description

Identifies the part number of the enclosure's backplane.

Syntax

Integer

Access

Read-only

Enclosure SCSI ID
Name

enclosureSCSIID

Object ID

1.3.6.1.4.1.674.10893.1.20.130.3.1.22

Description

Identifies the SCSI ID of the controller to which the enclosure is
attached.

Syntax

Integer

Access

Read-only

Enclosure Roll-Up Status
Name

enclosureRollUpStatus

Object ID

1.3.6.1.4.1.674.10893.1.20.130.3.1.23

Description

Identifies the severity of the enclosure state. This is the combined
status of the enclosure and its components. Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable

Syntax

DellStatus

Access

Read-only

Storage Management Group

601

Enclosure Component Status
Name

enclosureComponentStatus

Object ID

1.3.6.1.4.1.674.10893.1.20.130.3.1.24

Description

Identifies the status of the enclosure itself without the
propagation of any contained component status. Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable

Syntax

DellStatus

Access

Read-only

Enclosure Nexus ID
Name

enclosureNexusID

Object ID

1.3.6.1.4.1.674.10893.1.20.130.3.1.25

Description

Identifies the durable unique ID for the enclosure.

Syntax

Integer

Access

Read-only

Enclosure FirmWare Version
Name

enclosureFirmwareVersion

Object ID

1.3.6.1.4.1.674.10893.1.20.130.3.1.26

Description

Displays the firmware version of the enclosure.

Syntax

DisplayString

Access

Read-only

602

Storage Management Group

Enclosure SCSI Rate
Name

enclosureSCSIRate

Object ID

1.3.6.1.4.1.674.10893.1.20.130.3.1.27

Description

Displays the actual SCSI rate in the enclosure.

Syntax

DisplayString

Access

Read-only

Enclosure Part Number
Name

enclosurePartNumber

Object ID

1.3.6.1.4.1.674.10893.1.20.130.3.1.28

Description

Displays the part number of the enclosure.

Syntax

DisplayString

Access

Read-only

Enclosure Serial Number
Name

enclosureSerialNumber

Object ID

1.3.6.1.4.1.674.10893.1.20.130.3.1.29

Description

Displays the serial number of the enclosure.

Syntax

DisplayString

Access

Read-only

Enclosure SAS Address
Name

enclosureSASAddress

Object ID

1.3.6.1.4.1.674.10893.1.20.130.3.1.30

Description

Displays the specified SAS address if the enclosure is a SAS
enclosure.

Syntax

DisplayString

Access

Read-only

Storage Management Group

603

Enclosure Occupied Slot Count
Name

enclosureOccupiedSlotCount

Object ID

1.3.6.1.4.1.674.10893.1.20.130.3.1.31

Description

Displays the number of physical disk slots occupied in a storage
enclosure.

NOTE: A value of 9999 indicates that the feature is not available.
Syntax

Integer

Access

Read-only

Enclosure Total Slots
Name

enclosureTotalSlots

Object ID

1.3.6.1.4.1.674.10893.1.20.130.3.1.32

Description

Displays the total number of physical slots in a storage enclosure;
it includes total count of occupied and empty slots.

NOTE: A value of 9999 indicates that the feature is not available.
Syntax

Integer

Access

Read-only

Enclosure Empty Slot Count
Name

enclosureEmptySlotCount

Object ID

1.3.6.1.4.1.674.10893.1.20.130.3.1.33

Description

Displays the number of empty physical disk slots in a storage
enclosure.

NOTE: A value of 9999 indicates that the feature is not available
Syntax

Integer

Access

Read-only

604

Storage Management Group

Array Disk Table
This section describes available properties for each physical array disk on the
managed system.
The following object sets up the Array Disk Table.
Name

arrayDiskTable

Object ID

1.3.6.1.4.1.674.10893.1.20.130.4

Description

Defines the array disk table.

Syntax

SEQUENCE OF ArrayDiskEntry

Access

Not accessible

Array Disk Entry
Name

arrayDiskEntry

Object ID

1.3.6.1.4.1.674.10893.1.20.130.4.1

Description

Defines the array disk table entry.

Syntax

ArrayDiskEntry

Access

Not accessible

Index

arrayDiskNumber

Array Disk Number
Name

arrayDiskNumber

Object ID

1.3.6.1.4.1.674.10893.1.20.130.4.1.1

Description

Identifies the instance number of the array disk entry.

Syntax

Integer

Access

Read-only

Storage Management Group

605

Array Disk Name
Name

arrayDiskName

Object ID

1.3.6.1.4.1.674.10893.1.20.130.4.1.2

Description

Identifies the name of the array disk as represented in Storage
Management.

Syntax

DisplayString

Access

Read-only

Array Disk Vendor
Name

arrayDiskVendor

Object ID

1.3.6.1.4.1.674.10893.1.20.130.4.1.3

Description

Displays the array disk's manufacturer's name.

Syntax

DisplayString

Access

Read-only

606

Storage Management Group

Array Disk State
Name

arrayDiskState

Object ID

1.3.6.1.4.1.674.10893.1.20.130.4.1.4

Storage Management Group

607

Name

arrayDiskState

Description

Identifies the current state of the array disk. Possible states:
0: Unknown
1: Ready - Available for use, but no RAID configuration has been
assigned.
2: Failed - Not operational.
3: Online - Operational. RAID configuration has been assigned.
4: Offline - The drive is not available to the RAID controller.
6: Degraded - Refers to a fault-tolerant array/virtual disk that has a
failed disk.
7: Recovering - Refers to a state of recovering from bad blocks on
disks.
11: Removed - Indicates that the array disk has been removed.
13: Non-RAID - Indicates that the array disk is not a RAID capable
disk.
14: Not Ready - Applicable for PCIeSSD devices indicating that
the device is in locked state.
15: Resynching - Indicates one of the following types of disk
operations: Transform Type, Reconfiguration, and Check
Consistency.
22: Replacing - Indicates copyback operation is in progress.
24: Rebuild
25: No Media - CD-ROM or removable disk has no media.
26: Formatting - In the process of formatting.
28: Diagnostics - Diagnostics are running.
34: Predictive Failure
35: Initializing: Applies only to virtual disks on PERC, PERC
2/SC, and PERC 2/DC controllers.
39: Foreign
40: Clear
41: Unsupported
53: Incompatible
56: Read Only - Applicable for PCIeSSD devices. Indicates that
device has reached read-only state.

608

Storage Management Group

Name

arrayDiskState

Syntax

Integer

Access

Read-only

Array Disk Severity
Name

arrayDiskSeverity

Object ID

1.3.6.1.4.1.674.10893.1.20.130.4.1.5

Description

This entry is obsolete for Storage Management. It is replaced with
RollUpStatus and ComponentStatus for each device.

Syntax

Integer

Access

Read-only

Array Disk Product ID
Name

arrayDiskProductID

Object ID

1.3.6.1.4.1.674.10893.1.20.130.4.1.6

Description

Identifies the model number of the array disk.

Syntax

DisplayString

Access

Read-only

Array Disk Serial Number
Name

arrayDiskSerialNo

Object ID

1.3.6.1.4.1.674.10893.1.20.130.4.1.7

Description

Identifies the array disk's unique identification number from the
manufacturer.

Syntax

DisplayString

Access

Read-only

Storage Management Group

609

Array Disk Revision
Name

arrayDiskRevision

Object ID

1.3.6.1.4.1.674.10893.1.20.130.4.1.8

Description

Identifies the firmware version of the array disk.

Syntax

DisplayString

Access

Read-only

Array Disk Enclosure ID
Name

arrayDiskEnclosureID

Object ID

1.3.6.1.4.1.674.10893.1.20.130.4.1.9

Description

Identifies the SCSI ID of the enclosure processor to which the
array disk belongs.

Syntax

DisplayString

Access

Read-only

Array Disk Channel
Name

arrayDiskChannel

Object ID

1.3.6.1.4.1.674.10893.1.20.130.4.1.10

Description

Identifies the bus to which the array disk is connected.

Syntax

Integer

Access

Read-only

Array Disk Length in Megabytes
Name

arrayDiskLengthInMB

Object ID

1.3.6.1.4.1.674.10893.1.20.130.4.1.11

Description

Identifies the size, in megabytes of the array disk. If this size is 0,
the size is smaller than a megabyte.

Syntax

Integer

Access

Read-only

610

Storage Management Group

Array Disk Length in Bytes
Name

arrayDiskLengthInBytes

Object ID

1.3.6.1.4.1.674.10893.1.20.130.4.1.12

Description

Identifies the size of the array disk (in bytes) that is less than a
megabyte. This size plus the arrayDiskLengthInMB is the total
size of the array disk.

Syntax

Integer

Access

Read-only

Array Disk Largest Contiguous Free Space in Megabytes
Name

arrayDiskLargestContiguousFreeSpaceInMB

Object ID

1.3.6.1.4.1.674.10893.1.20.130.4.1.13

Description

The size in (megabytes) of the largest contiguous free space on the
array disk. If this size is 0, the free space on the array dissk is less
than a megabyte.

Syntax

Integer

Access

Read-only

Array Disk Largest Contiguous Free Space in Bytes
Name

arrayDiskLargestContiguousFreeSpaceInBytes

Object ID

1.3.6.1.4.1.674.10893.1.20.130.4.1.14

Description

The size of the largest contiguous free space on this array disk (in
bytes) that is less than a megabyte.This size plus the
arrayDiskLargestContiguousFreeSpaceInMB is the total size of
the largest contiguous free space on the array disk.

Syntax

Integer

Access

Read-only

Array Disk Target ID
Name

arrayDiskTargetID

Object ID

1.3.6.1.4.1.674.10893.1.20.130.4.1.15

Description

Identifies the SCSI target ID to which the array disk is assigned.

Storage Management Group

611

Name

arrayDiskTargetID

Syntax

Integer

Access

Read-only

Array Disk LUN ID
Name

arrayDiskLunID

Object ID

1.3.6.1.4.1.674.10893.1.20.130.4.1.16

Description

Identifies the array disk's logical unit number.

Syntax

Integer

Access

Read-only

Array Disk Used Space in Megabytes
Name

arrayDiskUsedSpaceInMB

Object ID

1.3.6.1.4.1.674.10893.1.20.130.4.1.17

Description

Identifies the amount (in megabytes) of used space on the array
disk. If this size is 0, used space on the array disk is smaller than a
megabyte.

Syntax

Integer

Access

Read-only

Array Disk Used Space in Bytes
Name

arrayDiskUsedSpaceInBytes

Object ID

1.3.6.1.4.1.674.10893.1.20.130.4.1.18

Description

Identifies the size in bytes of the used space on the array disk that
is smaller than a megabyte. This size plus the
arrayDiskUsedSpaceInMB is the total amount of used space on
the array disk.

Syntax

Integer

Access

Read-only

612

Storage Management Group

Array Disk Free Space in Megabytes
Name

arrayDiskFreeSpaceInMB

Object ID

1.3.6.1.4.1.674.10893.1.20.130.4.1.19

Description

Identifies the amount (in megabytes) of the free space on the array
disk. If this size is 0, the free space on the array disk is smaller than
a megabyte.

Syntax

Integer

Access

Read-only

Storage Management Group

613

Array Disk Free Space in Bytes
Name

arrayDiskFreeSpaceInBytes

Object ID

1.3.6.1.4.1.674.10893.1.20.130.4.1.20

Description

Identifies the size (in bytes) of the free space on the array disk that
is smaller than a megabyte. This size plus the
arrayDiskFreeSpaceInMB is the total amount of free space on the
array disk.

Syntax

Integer

Access

Read-only

Array Disk Bus Type
Name

arrayDiskBusType

Object ID

1.3.6.1.4.1.674.10893.1.20.130.4.1.21

Description

Identifies the bus type of the array disk. Possible values:
1: SCSI
2: IDE
3: Fibre Channel
4: SSA
6: USB
7: SATA
8: SAS
9: PCIe

Syntax

Integer

Access

Read-only

614

Storage Management Group

Array Disk Spare State
Name

arrayDiskSpareState

Object ID

1.3.6.1.4.1.674.10893.1.20.130.4.1.22

Description

Identifies the status of the array disk as a spare. Possible states:
1: Disk is a member of a virtual disk
2: Disk is a member of a disk group
3: Disk is a global hot spare
4: Disk is a dedicated hot spare
5: Not a spare
99: Not applicable

Syntax

Integer

Access

Read-only

Array Disk Roll-Up Status
Name

arrayDiskRollUpStatus

Object ID

1.3.6.1.4.1.674.10893.1.20.130.4.1.23

Description

Identifies the severity of the array disk state. This is the combined
status of the array disk and its components. Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable

Syntax

DellStatus

Access

Read-only

Storage Management Group

615

Array Disk Component Status
Name

arrayDiskComponentStatus

Object ID

1.3.6.1.4.1.674.10893.1.20.130.4.1.24

Description

Identifies the status of the array disk itself without the
propagation of any contained component status. Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable

Syntax

DellStatus

Access

Read-only

Array Disk Device Name
Name

arrayDiskDeviceName

Object ID

1.3.6.1.4.1.674.10893.1.20.130.4.1.25

Description

Identifies the operating system device name for the array disk.

Syntax

DisplayString

Access

Read-only

Array Disk Nexus ID
Name

arrayDiskNexusID

Object ID

1.3.6.1.4.1.674.10893.1.20.130.4.1.26

Description

Indicates the durable unique ID for the array disk.

Syntax

DisplayString

Access

Read-only

616

Storage Management Group

Array Disk Part Number
Name

arrayDiskPartNumber

Object ID

1.3.6.1.4.1.674.10893.1.20.130.4.1.27

Description

Indicates the part number of the disk.

Syntax

DisplayString

Access

Read-only

Array Disk SAS Address
Name

arrayDiskSASAddress

Object ID

1.3.6.1.4.1.674.10893.1.20.130.4.1.28

Description

Indicates the specified SAS address if this is a SAS disk.

Syntax

DisplayString

Access

Read-only

Array Disk Negotiated Speed
Name

arrayDiskNegotiatedSpeed

Object ID

1.3.6.1.4.1.674.10893.1.20.130.4.1.29

Description

Indicates the speed at which the drive is actually running in MPS
(megabytes per second).

Syntax

Integer

Access

Read-only

Array Disk Capable Speed
Name

arrayDiskCapableSpeed

Object ID

1.3.6.1.4.1.674.10893.1.20.130.4.1.30

Description

Indicates the maximum speed at which the drive is capable of
negotiating in MPS (megabytes per second).

Syntax

Integer

Access

Read-only

Storage Management Group

617

Array Disk Smart Alert Indication
Name

arrayDiskSmartAlertIndication

Object ID

1.3.6.1.4.1.674.10893.1.20.130.4.1.31

Description

Indicates whether the disk has received a predictive failure.
Possible values:
1: No - disk has not received a predictive failure alert
2: Yes - disk has received a predictive failure alert

Syntax

Integer

Access

Read-only

Array Disk Manufacture Day
Name

arrayDiskManufactureDay

Object ID

1.3.6.1.4.1.674.10893.1.20.130.4.1.32

Description

Indicates the day of the week (1=Sunday through 7=Saturday)
the disk was manufactured.

Syntax

DisplayString

Access

Read-only

Array Disk Manufacture Week
Name

arrayDiskManufactureWeek

Object ID

1.3.6.1.4.1.674.10893.1.20.130.4.1.33

Description

Indicates the week (1 through 53) in which the disk was
manufactured.

Syntax

DisplayString

Access

Read-only

618

Storage Management Group

Array Disk Manufacture Year
Name

arrayDiskManufactureYear

Object ID

1.3.6.1.4.1.674.10893.1.20.130.4.1.34

Description

Indicates the four digit year in which the disk was manufactured.

Syntax

DisplayString

Access

Read-only

Array Disk Media Type
Name

arrayDiskMediaType

Object ID

1.3.6.1.4.1.674.10893.1.20.130.4.1.35

Description

Indicates the Media type of the array disk.
Possible Values:
1:unknown
2:hdd
3:ssd

Syntax

Integer

Access

Read-only

Array Disk Dell Certified
Name

arrayDiskDellCertified

Object ID

1.3.6.1.4.1.674.10893.1.20.130.4.1.36

Description

Indicates if the array disk is certified by Dell.
Possible Values:
1 - Certified
0 - Not Certified
99 - Unknown

Syntax

Integer

Access

Read-only

Storage Management Group

619

Array Disk Alta Vendor Id
Name

arrayDiskAltaVendorId

Object ID

1.3.6.1.4.1.674.10893.1.20.130.4.1.37

Description

Provides the vendor information for Alta interposer.

Syntax

Octet String

Access

Read-only

Array Disk Alta Product Id
Name

arrayDiskAltaProductId

Object ID

1.3.6.1.4.1.674.10893.1.20.130.4.1.38

Description

Provides the product ID for Alta interposer.

Syntax

Octet String

Access

Read-only

Array Disk Alta Revision Id
Name

arrayDiskAltaRevisionId

Object ID

1.3.6.1.4.1.674.10893.1.20.130.4.1.39

Description

Provides the revision ID for Alta interposer.

Syntax

Octet String

Access

Read-only

Array Disk Encryption Capable
Name

arrayDiskEncryptionCapable

Object ID

1.3.6.1.4.1.674.10893.1.20.130.4.1.40

Description

Indicates if the physical disk is encryption capable.
Possible Values:
1 - Capable
0 - Not Capable
99 - Not Applicable

Syntax

620

Integer

Storage Management Group

Name

arrayDiskEncryptionCapable

Access

Read-only

Array Disk Encrypted
Name

arrayDiskEncrypted

Object ID

1.3.6.1.4.1.674.10893.1.20.130.4.1.41

Description

Indicates if the physical disk is encryption enabled.
Possible Values:
1 - Yes
0 - No
99 - Not Applicable

Syntax

Integer

Access

Read-only

Array Disk Power State
Name

arrayDiskPowerState

Object ID

1.3.6.1.4.1.674.10893.1.20.130.4.1.42

Description

Indicates the power state of a physical drive.
Possible Values:
0 - Spun up
1- Spun down
255 - Transition
99 - Not Applicable

Syntax

Integer

Access

Read-only

Array Disk Drive Write Cache
Name

arrayDiskDriveWriteCache

Object ID

1.3.6.1.4.1.674.10893.1.20.130.4.1.43

Storage Management Group

621

Name

arrayDiskDriveWriteCache

Description

Indicates the drive write cache capability for PCIe SSD devices.
Possible Values:
1 - Enabled
0 - Disabled
99 - Undetermined/NotApplicable

Syntax

Integer

Access

Read-only

Array Disk Model Number
Name

arrayDiskModelNumber

Object ID

1.3.6.1.4.1.674.10893.1.20.130.4.1.44

Description

Provides the PCIe SSD device model number.

Syntax

DisplayString

Access

Read-only

Array Disk Life Remaining
Name

arrayDiskLifeRemaining

Object ID

1.3.6.1.4.1.674.10893.1.20.130.4.1.45

Description

Provides the PCIe SSD device life remaining in percentage.
Possible Values: 0..100, 999 - Undetermined/Not Applicable

Syntax

Integer (0..100)

Access

Read-only

Array Disk Driver Version
Name

arrayDiskDriverVersion

Object ID

1.3.6.1.4.1.674.10893.1.20.130.4.1.46

Description

Provides the PCIe SSD device driver version.

Syntax

Integer

Access

Read-only

622

Storage Management Group

Array Disk Device Life Status
Name

arrayDiskDeviceLifeStatus

Object ID

1.3.6.1.4.1.674.10893.1.20.130.4.1.47

Description

Provides the PCIe SSD device life status.
Possible Values:
-1: Not Available / Not Applicable
1: Drive Health Good
2: Approaching Warranty Coverage Expiry
3: Warranty Coverage Expired
4: Approaching Read Only
5: Read Only

Syntax

Integer

Access

Read-only

Array Disk Enclosure Connection Table
This section describes the connections among array disks, their enclosure, and
their associated controller. For each object in the table, its object number
corresponds to an instance number in the appropriate MIB table for that
object where all of the object properties can be found.
NOTE: Only array disks that are part of an enclosure are listed in this table.
Backplanes are considered enclosures by Storage Management.
The following object sets up the Array Disk Enclosure Connection Table.
Name

arrayDiskEnclosureConnectionTable

Object ID

1.3.6.1.4.1.674.10893.1.20.130.5

Description

Defines the array disk enclosure connection table.

Syntax

SEQUENCE OF ArrayDiskEnclosureConnectionEntry

Access

Not accessible

Storage Management Group

623

Array Disk Enclosure Connection Entry
Name

arrayDiskEnclosureConnectionEntry

Object ID

1.3.6.1.4.1.674.10893.1.20.130.5.1

Description

Defines the array disk enclosure connection table entry.

Syntax

ArrayDiskEnclosureConnectionEntry

Access

Not accessible

Index

arrayDiskEnclosureConnectionNumber

Array Disk Enclosure Connection Number
Name

arrayDiskEnclosureConnectionNumber

Object ID

1.3.6.1.4.1.674.10893.1.20.130.5.1.1

Description

Identifies the instance number of the array disk enclosure
connection entry.

Syntax

Integer

Access

Read-only

Array Disk Enclosure Connection Array Disk Name
Name

arrayDiskEnclosureConnectionArrayDiskName

Object ID

1.3.6.1.4.1.674.10893.1.20.130.5.1.2

Description

Identifies the name of the array disk in the connection as
represented in Storage Management.

Syntax

DisplayString

Access

Read-only

Array Disk Enclosure Connection Array Disk Number
Name

arrayDiskEnclosureConnectionArrayDiskNumber

Object ID

1.3.6.1.4.1.674.10893.1.20.130.5.1.3

Description

Identifies the instance number of the array disk in the
arrayDiskTable in this connection.

Syntax

Integer

624

Storage Management Group

Name

arrayDiskEnclosureConnectionArrayDiskNumber

Access

Read-only

Array Disk Enclosure Connection Enclosure Name
Name

arrayDiskEnclosureConnectionEnclosureName

Object ID

1.3.6.1.4.1.674.10893.1.20.130.5.1.4

Description

Identifies the name of the enclosure as represented in Storage
Management to which this array disk belongs.

Syntax

DisplayString

Access

Read-only

Array Disk Enclosure Connection Enclosure Number
Name

arrayDiskEnclosureConnectionEnclosureNumber

Object ID

1.3.6.1.4.1.674.10893.1.20.130.5.1.5

Description

Identifies the instance number in the enclosureTable of the
enclosure to which this array disk belongs.

Syntax

Integer

Access

Read-only

Array Disk Enclosure Connection Controller Name
Name

arrayDiskEnclosureConnectionControllerName

Object ID

1.3.6.1.4.1.674.10893.1.20.130.5.1.6

Description

Identifies the name of the controller as represented in Storage
Management to which this array disk is connected.

Syntax

DisplayString

Access

Read-only

Array Disk Enclosure Connection Controller Number
Name

arrayDiskEnclosureConnectionControllerNumber

Object ID

1.3.6.1.4.1.674.10893.1.20.130.5.1.7

Storage Management Group

625

Name

arrayDiskEnclosureConnectionControllerNumber

Description

Identifies the instance number in the controllerTable of the
controller to which this array disk is connected.

Syntax

Integer

Access

Read-only

Array Disk Channel Connection Table
This section describes the connections between array disks, their channel,
and their associated controller. For each object in the table, its object
number corresponds to an instance number in the appropriate MIB table for
that object where all of the object properties can be found.
NOTE: Only array disks that are NOT part of an enclosure are listed in this table.
Backplanes are considered enclosures by Storage Management.
The following object sets up the Array Disk Channel Connection Table.
Name

arrayDiskChannelConnectionTable

Object ID

1.3.6.1.4.1.674.10893.1.20.130.6

Description

Defines the array disk channel connection table.

Syntax

SEQUENCE OF ArrayDiskChannelConnectionEntry

Access

Not accessible

Array Disk Channel Connection Entry
Name

arrayDiskChannelConnectionEntry

Object ID

1.3.6.1.4.1.674.10893.1.20.130.6.1

Description

Defines the array disk channel connection table entry.

Syntax

ArrayDiskChannelConnectionEntry

Access

Not accessible

Index

arrayDiskEnclosureConnectionNumber

Array Disk Channel Connection Number
Name

arrayDiskChannelConnectionNumber

Object ID

1.3.6.1.4.1.674.10893.1.20.130.6.1.1

626

Storage Management Group

Name

arrayDiskChannelConnectionNumber

Description

Identifies the instance number of the array disk channel
connection entry.

Syntax

Integer

Access

Read-only

Array Disk Channel Connection Array Disk Name
Name

arrayDiskChannelConnectionArrayDiskName

Object ID

1.3.6.1.4.1.674.10893.1.20.130.6.1.2

Description

Identifies the name of the array disk in the connection as
represented in Storage Management.

Syntax

DisplayString

Access

Read-only

Array Disk Channel Connection Array Disk Number
Name

arrayDiskChannelConnectionArrayDiskNumber

Object ID

1.3.6.1.4.1.674.10893.1.20.130.6.1.3

Description

Identifies the instance number of the array disk in the
arrayDiskTable in the connection.

Syntax

Integer

Access

Read-only

Array Disk Channel Connection Channel Name
Name

arrayDiskChannelConnectionChannelName

Object ID

1.3.6.1.4.1.674.10893.1.20.130.6.1.4

Description

Identifies the name of the channel as represented in Storage
Management to which the array disk is connected.

Syntax

DisplayString

Access

Read-only

Storage Management Group

627

Array Disk Channel Connection Channel Number
Name

arrayDiskChannelConnectionChannelNumber

Object ID

1.3.6.1.4.1.674.10893.1.20.130.6.1.5

Description

Identifies the instance number of the channel in the channelTable
to which the array disk is connected.

Syntax

Integer

Access

Read-only

Array Disk Channel Connection Controller Name
Name

arrayDiskChannelConnectionControllerName

Object ID

1.3.6.1.4.1.674.10893.1.20.130.6.1.6

Description

Identifies the name of the controller as represented in Storage
Management to which the array disk is connected.

Syntax

DisplayString

Access

Read-only

Array Disk Channel Connection Controller Number
Name

arrayDiskChannelConnectionControllerNumber

Object ID

1.3.6.1.4.1.674.10893.1.20.130.6.1.7

Description

Identifies the instance number in the controllerTable of the
controller to which the array disk is connected.

Syntax

Integer

Access

Read-only

Fan Table
This section describes available properties for each fan on the managed
system.
The following object sets up the Fan Table.
Name

fanTable

Object ID

1.3.6.1.4.1.674.10893.1.20.130.7

Description

Defines the fan table.

628

Storage Management Group

Name

fanTable

Syntax

SEQUENCE OF FanEntry

Access

Not accessible

Fan Entry
Name

fanEntry

Object ID

1.3.6.1.4.1.674.10893.1.20.130.7.1

Description

Defines the fan table entry.

Syntax

FanEntry

Access

Not accessible

Index

fanNumber

Fan Number
Name

fanNumber

Object ID

1.3.6.1.4.1.674.10893.1.20.130.7.1.1

Description

Identifies the instance number of the fan entry.

Syntax

Integer

Access

Read-only

Fan Name
Name

Fan Name

Object ID

1.3.6.1.4.1.674.10893.1.20.130.7.1.2

Description

Identifies the fan's name as represented in Storage Management.

Syntax

DisplayString

Access

Read-only

Fan Vendor
Name

fanVendor

Object ID

1.3.6.1.4.1.674.10893.1.20.130.7.1.3

Storage Management Group

629

Name

fanVendor

Description

Identifies the fan's (re)seller's name.

Syntax

DisplayString

Access

Read-only

630

Storage Management Group

Fan State
Name

fanState

Object ID

1.3.6.1.4.1.674.10893.1.20.130.7.1.4

Description

Identifies the current state of the fan. Possible states:
0: Unknown
1: Ready
2: Failed
3: Online
4: Offline
6: Degraded
21: Missing

Syntax

Integer

Access

Read-only

Fan Severity
Name

fanSeverity

Object ID

1.3.6.1.4.1.674.10893.1.20.130.7.1.5

Description

This entry is obsolete for Storage Management. It is replaced with
RollUpStatus and ComponentStatus for each device.

Syntax

Integer

Access

Read-only

Fan Probe Unit
Name

fanProbeUnit

Object ID

1.3.6.1.4.1.674.10893.1.20.130.7.1.6

Description

This entry is obsolete for Storage Services.

Syntax

DisplayString

Access

Read-only

Storage Management Group

631

Fan Probe Minimum Warning
Name

fanProbeMinimumWarning

Object ID

1.3.6.1.4.1.674.10893.1.20.130.7.1.7

Description

This entry is obsolete. This setting is not supported by fans
managed under Storage Management.

Syntax

DisplayString

Access

Read-only

Fan Probe Minimum Critical
Name

fanProbeMinimumCritical

Object ID

1.3.6.1.4.1.674.10893.1.20.130.7.1.8

Description

This entry is obsolete. This setting is not supported by fans
managed under Storage Management.

Syntax

DisplayString

Access

Read-only

Fan Probe Maximum Warning
Name

fanProbeMaximumWarning

Object ID

1.3.6.1.4.1.674.10893.1.20.130.7.1.9

Description

This entry is obsolete. This setting is not supported by fans
managed under Storage Management.

Syntax

DisplayString

Access

Read-only

Fan Probe Maximum Critical
Name

fanProbeMaximumCritical

Object ID

1.3.6.1.4.1.674.10893.1.20.130.7.1.10

Description

This entry is obsolete. This setting is not supported by fans
managed under Storage Management.

Syntax

DisplayString

Access

Read-only

632

Storage Management Group

Fan Probe Current Value
Name

fanProbeCurrValue

Object ID

1.3.6.1.4.1.674.10893.1.20.130.7.1.11

Description

Identifies the current speed of the fan.

Syntax

DisplayString

Access

Read-only

Fan1 Part Number
Name

fan1PartNumber

Object ID

1.3.6.1.4.1.674.10893.1.20.130.7.1.12

Description

Identifies the part number of the fan in the enclosure.

Syntax

DisplayString

Access

Read-only

Fan 2 Part Number
Name

fan2PartNumber

Object ID

1.3.6.1.4.1.674.10893.1.20.130.7.1.13

Description

This entry is obsolete. This setting is not supported by fans
managed under Storage Management.

Syntax

DisplayString

Access

Read-only

Storage Management Group

633

Fan Roll-Up Status
Name

fanRollUpStatus

Object ID

1.3.6.1.4.1.674.10893.1.20.130.7.1.14

Description

Severity of the fan state. This is the combined status of the fan
and its components. Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable

Syntax

DellStatus

Access

Read-only

Fan Component Status
Name

fanComponentStatus

Object ID

1.3.6.1.4.1.674.10893.1.20.130.7.1.15

Description

The status of the fan itself without the propagation of any
contained component status. Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable

Syntax

DellStatus

Access

Read-only

634

Storage Management Group

Fan Nexus ID
Name

fanNexusID

Object ID

1.3.6.1.4.1.674.10893.1.20.130.7.1.16

Description

Durable unique ID for the fan.

Syntax

DisplayString

Access

Read-only

Fan Revision
Name

fanRevision

Object ID

1.3.6.1.4.1.674.10893.1.20.130.7.1.17

Description

Indicates the revision number of the fan in the enclosure.

Syntax

DisplayString

Access

Read-only

Fan Connection Table
This section describes the connection between each fan on the managed
system and its enclosure. Each enclosure number in the table corresponds to
that enclosure instance in the enclosure Table.
The following object sets up the Fan Connection Table.
Name

fanConnectionTable

Object ID

fanConnectionTable

Description

Defines the fan connection table.

Syntax

SEQUENCE OF FanConnectionEntry

Access

Not accessible

Fan Connection Entry
Name

fanConnectionEntry

Object ID

1.3.6.1.4.1.674.10893.1.20.130.8.1

Description

Defines the fan connection table entry.

Storage Management Group

635

Name

fanConnectionEntry

Syntax

FanConnectionEntry

Access

Not accessible

Index

fanConnectionNumber

Fan Connection Number
Name

fanConnectionNumber

Object ID

1.3.6.1.4.1.674.10893.1.20.130.8.1.1

Description

Identifies the instance number of the fan connection entry.

Syntax

Integer

Access

Read-only

Fan Connection Fan Name
Name

fanConnectionFanName

Object ID

1.3.6.1.4.1.674.10893.1.20.130.8.1.2

Description

Identifies the name of the fan in the connection as represented in
Storage Management.

Syntax

DisplayString

Access

Read-only

Fan Connection Fan Number
Name

fanConnectionFanNumber

Object ID

1.3.6.1.4.1.674.10893.1.20.130.8.1.3

Description

Identifies the instance number of the fan in the fanTable in the
connection.

Syntax

Integer

Access

Read-only

636

Storage Management Group

Fan Connection Enclosure Name
Name

fanConnectionEnclosureName

Object ID

1.3.6.1.4.1.674.10893.1.20.130.8.1.4

Description

Identifies the name of the enclosure as represented in Storage
Management to which the fan belongs.

Syntax

DisplayString

Access

Read-only

Fan Connection Enclosure Number
Name

fanConnectionEnclosureNumber

Object ID

1.3.6.1.4.1.674.10893.1.20.130.8.1.5

Description

Identifies the instance number of the enclosure in the
enclosureTable to which the fan belongs.

Syntax

Integer

Access

Read-only

Power Supply Table
This section describes available properties for each power supply on the
managed system.
The following object sets up the Power Supply Table.
Name

powerSupplyTable

Object ID

1.3.6.1.4.1.674.10893.1.20.130.9

Description

Defines the power supply table.

Syntax

SEQUENCE OF PowerSupplyEntry

Access

Not accessible

Storage Management Group

637

Power Supply Entry
Name

powerSupplyEntry

Object ID

1.3.6.1.4.1.674.10893.1.20.130.9.1

Description

Defines the power supply table entry.

Syntax

PowerSupplyEntry

Access

Not accessible

Index

powerSupplyNumber

Power Supply Number
Name

powerSupplyNumber

Object ID

1.3.6.1.4.1.674.10893.1.20.130.9.1.1

Description

Identifies the instance number of the power supply entry.

Syntax

Integer

Access

Read-only

Power Supply Name
Name

powerSupplyName

Object ID

1.3.6.1.4.1.674.10893.1.20.130.9.1.2

Description

Identifies the power supply's name as represented in Storage
Management.

Syntax

DisplayString

Access

Read-only

Power Supply Vendor
Name

powerSupplyVendor

Object ID

1.3.6.1.4.1.674.10893.1.20.130.9.1.3

Description

Identifies the power supply's (re)seller's name.

Syntax

DisplayString

Access

Read-only

638

Storage Management Group

Power Supply State
Name

powerSupplyState

Object ID

1.3.6.1.4.1.674.10893.1.20.130.9.1.4

Description

Identifies the current state of the power supply. Possible states:
0: Unknown
1: Ready
2: Failed
5: Not Installed
6: Degraded
11: Removed

Syntax

Integer

Access

Read-only

Power Supply Severity
Name

powerSupplySeverity

Object ID

1.3.6.1.4.1.674.10893.1.20.130.9.1.5

Description

This entry is obsolete for Storage Management. It is replaced with
RollUpStatus and ComponentStatus for each device.

Syntax

Integer

Access

Read-only

Power Supply 1 Part Number
Name

powerSupply1PartNumber

Object ID

1.3.6.1.4.1.674.10893.1.20.130.9.1.6

Description

Identifies the part number of the power supply of the enclosure.

Syntax

DisplayString

Access

Read-only

Storage Management Group

639

Power Supply 2 Part Number
Name

powerSupply2PartNumber

Object ID

1.3.6.1.4.1.674.10893.1.20.130.9.1.7

Description

This entry is obsolete. This setting is not supported by power
supplies managed under Storage Management

Syntax

DisplayString

Access

Read-only

Power Supply Roll-Up Status
Name

powerSupplyRollUpStatus

Object ID

1.3.6.1.4.1.674.10893.1.20.130.9.1.8

Description

Identifies the severity of the power supply state. This is the
combined status of the power supply and its components.
Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable

Syntax

DellStatus

Access

Read-only

640

Storage Management Group

Power Supply Component Status
Name

powerSupplyComponentStatus

Object ID

1.3.6.1.4.1.674.10893.1.20.130.9.1.9

Description

Severity of the power supply state. This is the combined status of
the power supply and its components. Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable

Syntax

DellStatus

Access

Read-only

Power Supply NexusID
Name

powerSupplyNexusID

Object ID

1.3.6.1.4.1.674.10893.1.20.130.9.1.10

Description

Durable unique ID for the power supply.

Syntax

DisplayString

Access

Read-only

Power Supply Revision
Name

powerSupplyRevision

Object ID

1.3.6.1.4.1.674.10893.1.20.130.9.1.11

Description

Indicates the revision number of the power supply in the
enclosure.

Syntax

DisplayString

Access

Read-only

Storage Management Group

641

Power Supply Connection Table
This section describes the connection between each power supply on the
managed system and its enclosure. Each enclosure number in the table
corresponds to that enclosure instance in the enclosure Table.
The following object sets up the Power Supply Connection Table.
Name

powerSupplyConnectionTable

Object ID

1.3.6.1.4.1.674.10893.1.20.130.10

Description

Defines the power supply connection table.

Syntax

SEQUENCE OF PowerSupplyConnectionEntry

Access

Not accessible

Power Supply Connection Entry
Name

powerSupplyConnectionEntry

Object ID

1.3.6.1.4.1.674.10893.1.20.130.10.1

Description

Defines the power supply connection table entry.

Syntax

PowerSupplyConnectionEntry

Access

Not accessible

Index

powerSupplyConnectionNumber

Power Supply Connection Number
Name

powerSupplyConnectionNumber

Object ID

1.3.6.1.4.1.674.10893.1.20.130.10.1.1

Description

Identifies the instance number of the power supply connection
entry.

Syntax

Integer

Access

Read-only

642

Storage Management Group

Power Supply Connection Power Supply Name
Name

powerSupplyConnectionPowerSupplyName

Object ID

1.3.6.1.4.1.674.10893.1.20.130.10.1.2

Description

Identifies the name of the power supply in the connection as
represented in Storage Management.

Syntax

DisplayString

Access

Read-only

Power Supply Connection Power Supply Number
Name

powerSupplyConnectionPowerSupplyNumber

Object ID

1.3.6.1.4.1.674.10893.1.20.130.10.1.3

Description Identifies the instance number of the power supply in the
powerSupplyTable in the connection.
Syntax

Integer

Access

Read-only

Power Supply Connection Enclosure Name
Name

powerSupplyConnectionEnclosureName

Object ID

1.3.6.1.4.1.674.10893.1.20.130.10.1.4

Description

Identifies the name of the enclosure as represented in Storage
Management to which the power supply belongs.

Syntax

DisplayString

Access

Read-only

Power Supply Connection Enclosure Number
Name

powerSupplyConnectionEnclosureNumber

Object ID

1.3.6.1.4.1.674.10893.1.20.130.10.1.5

Description

Identifies the instance number of the enclosure in the
enclosureTable to which the power supply belongs.

Syntax

Integer

Access

Read-only

Storage Management Group

643

Power Supply Connection Firmware Version
Name

powerSupplyConnectionFirmwareVersion

Object ID

1.3.6.1.4.1.674.10893.1.20.130.10.1.6

Description

Displays power supply connection firmware version.

NOTE: Available above 1.04 firmware version.
Syntax

DisplayString

Access

Read-only

Temperature Probe Table
This section describes available properties for each temperature probe on the
managed system.
The following object sets up the Temperature Probe Table.
Name

temperatureProbeTable

Object ID

1.3.6.1.4.1.674.10893.1.20.130.11

Description

A table of managed temperature probes. The number of entries is
related to the number of temperature probes discovered in the
system. The maximum number of entries is implementation
dependent.

NOTE: The properties in this table may not be applicable to all entries.
Syntax

SEQUENCE OF TemperatureProbeEntry

Access

Not accessible

Temperature Probe Entry
Name

temperatureProbeEntry

Object ID

1.3.6.1.4.1.674.10893.1.20.130.11.1

Description

Defines the Temperature Probe Table. A row in this table cannot
be created or deleted by SNMP operations on columns of the
table.

Syntax

TemperatureProbeEntry

644

Storage Management Group

Name

temperatureProbeEntry

Access

Not accessible

Index

TemperatureProbeNumber

Temperature Probe Number
Name

temperatureProbeNumber

Object ID

1.3.6.1.4.1.674.10893.1.20.130.11.1.1

Description

Identifies the instance number of the temperature probe entry.

Syntax

Integer

Access

Read-only

Temperature Probe Name
Name

temperatureProbeName

Object ID

1.3.6.1.4.1.674.10893.1.20.130.11.1.2

Description

Identifies the temperature probe's name as represented in Storage
Management.

Syntax

DisplayString

Access

Read-only

Temperature Probe Vendor
Name

temperatureProbeVendor

Object ID

1.3.6.1.4.1.674.10893.1.20.130.11.1.3

Description

Identifies the temperature probe's (re)seller's name.

Syntax

DisplayString

Access

Read-only

Temperature Probe State
Name

temperatureProbeState

Object ID

1.3.6.1.4.1.674.10893.1.20.130.11.1.4

Storage Management Group

645

Name

temperatureProbeState

Description

Identifies the current state of the temperature probe. Possible states:
0: Unknown
1: Ready
2: Failed (Minimum Failure Threshold Exceeded, Maximum Failure
Threshold Exceeded)
4: Offline
6: Degraded (Minimum Warning Threshold Exceeded, Maximum
Warning Threshold Exceeded)
9: Inactive
21: Missing

Syntax

Integer

Access

Read-only

Temperature Probe Severity
Name

temperatureProbeSeverity

Object ID

1.3.6.1.4.1.674.10893.1.20.130.11.1.5

Description

This entry is obsolete for Storage Management. It is replaced with
RollUpStatus and ComponentStatus for each device.

Syntax

Integer

Access

Read-only

Temperature Probe Unit
Name

temperatureProbeUnit

Object ID

1.3.6.1.4.1.674.10893.1.20.130.11.1.6

Description

Identifies the units that are used to display temperatures for the
temperature probe.

Syntax

DisplayString

Access

Read-only

646

Storage Management Group

Temperature Probe Minimum Warning
Name

temperatureProbeMinWarning

Object ID

1.3.6.1.4.1.674.10893.1.20.130.11.1.7

Description

Identifies the minimum temperature that forces the probe into a
warning state.

Syntax

Integer

Access

Read-only

Temperature Probe Minimum Critical
Name

temperatureProbeMinCritical

Object ID

1.3.6.1.4.1.674.10893.1.20.130.11.1.8

Description

Identifies the minimum temperature that forces the probe into an
error state.

Syntax

Integer

Access

Read-only

Temperature Probe Maximum Warning
Name

temperatureProbeMaxWarning

Object ID

1.3.6.1.4.1.674.10893.1.20.130.11.1.9

Description

Identifies the maximum temperature that forces the probe into a
warning state.

Syntax

Integer

Access

Read-only

Temperature Probe Maximum Critical
Name

temperatureProbeMaxCritical

Object ID

1.3.6.1.4.1.674.10893.1.20.130.11.1.10

Description

Identifies the maximum temperature that forces the probe into an
error state.

Syntax

Integer

Storage Management Group

647

Name

temperatureProbeMaxCritical

Access

Read-only

Temperature Probe Current Value
Name

temperatureProbeCurValue

Object ID

1.3.6.1.4.1.674.10893.1.20.130.11.1.11

Description

Identifies the current temperature of the probe.

Syntax

Integer

Access

Read-only

648

Storage Management Group

Temperature Probe Roll-Up Status
Name

temperatureProbeRollUpStatus

Object ID

1.3.6.1.4.1.674.10893.1.20.130.11.1.12

Description

Identifies the severity of the temperature probe state. This is the
combined status of the temperature probe and its components.
Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable

Syntax

DellStatus

Access

Read-only

Temperature Probe Component Status
Name

temperatureProbeComponentStatus

Object ID

1.3.6.1.4.1.674.10893.1.20.130.11.1.13

Description

Identifies the status of the temperature probe itself without the
propagation of any contained component status. Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable

Syntax

DellStatus

Access

Read-only

Storage Management Group

649

Temperature Probe Nexus ID
Name

temperatureProbeNexusID

Object ID

1.3.6.1.4.1.674.10893.1.20.130.11.1.14

Description

Displays the durable unique ID for this temperature probe.

Syntax

DisplayString

Access

Read-only

Temperature Probe Connection Table
This section describes the connection between each temperature probe on the
managed system and its enclosure. Each enclosure number in the table
corresponds to that enclosure instance in the enclosure Table.
The following object sets up the Temperature Probe Connection Table.
Name

temperatureConnectionTable

Object ID

1.3.6.1.4.1.674.10893.1.20.130.12

Description

Defines the temperature probe connection table.

Syntax

SEQUENCE OF TemperatureConnectionEntry

Access

Not accessible

Temperature Probe Connection Entry
Name

temperatureConnectionEntry

Object ID

1.3.6.1.4.1.674.10893.1.20.130.12.1

Description

Defines the temperature probe connection table entry.

Syntax

TemperatureConnectionEntry

Access

Not accessible

Index

temperatureConnectionNumber

650

Storage Management Group

Temperature Probe Connection Number
Name

temperatureConnectionNumber

Object ID

1.3.6.1.4.1.674.10893.1.20.130.12.1.1

Description

Identifies the instance number of the temperature probe
connection entry.

Syntax

Integer

Access

Read-only

Temperature Probe Connection Temperature Probe Name
Name

temperatureConnectionTemperatureName

Object ID

1.3.6.1.4.1.674.10893.1.20.130.12.1.2

Description

Identifies the name of the temperature probe in the connection as
represented in Storage Management.

Syntax

DisplayString

Access

Read-only

Temperature Probe Connection Temperature Probe Number
Name

temperatureConnectionTemperatureNumber

Object ID

1.3.6.1.4.1.674.10893.1.20.130.12.1.3

Description

Identifies the instance number in the temperatureTable of the
temperature probe in the connection.

Syntax

Integer

Access

Read-only

Temperature Probe Connection Enclosure Name
Name

temperatureConnectionEnclosureName

Object ID

1.3.6.1.4.1.674.10893.1.20.130.12.1.4

Description

Identifies the name of the enclosure as represented in Storage
Management to which the temperature probe belongs.

Syntax

DisplayString

Access

Read-only

Storage Management Group

651

Temperature Probe Connection Enclosure Number
Name

temperatureConnectionEnclosureNumber

Object ID

1.3.6.1.4.1.674.10893.1.20.130.12.1.5

Description

Identifies the instance number of the enclosure in the
enclosureTable to which the temperature probe belongs.

Syntax

Integer

Access

Read-only

Enclosure Management Module Table
This section describes available properties for each enclosure management
module on the managed system.
The following object sets up the Enclosure Management Module Table.
Name

enclosureManagementModuleTable

Object ID

1.3.6.1.4.1.674.10893.1.20.130.13

Description

Defines the enclosure management module table.

Syntax

SEQUENCE OF EnclosureManagementModuleEntry

Access

Not accessible

Enclosure Management Module Entry
Name

EnclosureManagementModuleEntry

Object ID

1.3.6.1.4.1.674.10893.1.20.130.13.1

Description

Defines the enclosure management module table entry.

Syntax

EnclosureManagementModuleEntry

Access

Not accessible

Index

enclosureManagementModuleNumber

652

Storage Management Group

Enclosure Management Module Number
Name

enclosureManagementModuleNumber

Object ID

1.3.6.1.4.1.674.10893.1.20.130.13.1.1

Description

Identifies the instance number of the enclosure management
module entry.

Syntax

Integer

Access

Read-only

Enclosure Management Module Name
Name

enclosureManagementModuleName

Object ID

1.3.6.1.4.1.674.10893.1.20.130.13.1.2

Description

Identifies the enclosure management module's name as
represented in Storage Management.

Syntax

DisplayString

Access

Read-only

Enclosure Management Module Vendor
Name

enclosureManagementModuleVendor

Object ID

1.3.6.1.4.1.674.10893.1.20.130.13.1.3

Description

Identifies the enclosure management module's (re)seller's name.

Syntax

DisplayString

Access

Read-only

Storage Management Group

653

Enclosure Management Module State
Name

enclosureManagementModuleState

Object ID

1.3.6.1.4.1.674.10893.1.20.130.13.1.4

Description

Identifies the current state of the enclosure management module.
Possible states:
0: Unknown
1: Ready
2: Failed
3: Online
4: Offline
5: Not Installed
6: Degraded
21: Missing

Syntax

Integer

Access

Read-only

Enclosure Management Module Severity
Name

enclosureManagementModuleSeverity

Object ID

1.3.6.1.4.1.674.10893.1.20.130.13.1.5

Description

This entry is obsolete for Storage Management. It is replaced with
RollUpStatus and ComponentStatus for each device.

Syntax

Integer

Access

Read-only

Enclosure Management Module Part Number
Name

enclosureManagementModulePartNumber

Object ID

1.3.6.1.4.1.674.10893.1.20.130.13.1.6

Description

Identifies the part number of the enclosure memory module.

Syntax

Display String

Access

Read-only

654

Storage Management Group

Enclosure Management Module Type
Name

enclosureManagementModuleType

Object ID

1.3.6.1.4.1.674.10893.1.20.130.13.1.7

Description

Identifies the type of enclosure management module. Possible
values:
0: Unknown
1: EMM
2: Termination Card

Syntax

Integer

Access

Read-only

Enclosure Management Module Firmware Version
Name

enclosureManagementModuleFWVersion

Object ID

1.3.6.1.4.1.674.10893.1.20.130.13.1.8

Description

Identifies the firmware version of the enclosure memory module.

Syntax

DisplayString

Access

Read-only

Enclosure Management Module Maximum Speed
Name

enclosureManagementModuleMaxSpeed

Object ID

1.3.6.1.4.1.674.10893.1.20.130.13.1.9

Description

Identifies the maximum bus speed of the enclosure management
module.

Syntax

DisplayString

Access

Read-only

Storage Management Group

655

Enclosure Management Module Roll-Up Status
Name

enclosureManagementModuleRollUpStatus

Object ID

1.3.6.1.4.1.674.10893.1.20.130.13.1.10

Description

Identifies the severity of the enclosure management module state.
This is the combined status of the EMM and its components.
Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable

Syntax

DellStatus

Access

Read-only

Enclosure Management Module Component Status
Name

enclosureManagementModuleComponentStatus

Object ID

1.3.6.1.4.1.674.10893.1.20.130.13.1.11

Description

Identifies the status of the enclosure management module itself
without the propagation of any contained component status.
Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable

Syntax

DellStatus

Access

Read-only

656

Storage Management Group

Enclosure Management Module Nexus ID
Name

enclosureManagementModuleNexusID

Object ID

1.3.6.1.4.1.674.10893.1.20.130.13.1.12

Description

Displays the durable unique ID for this EMM.

Syntax

DisplayString

Access

Read-only

Enclosure Management Module Revision
Name

enclosureManagementModuleRevision

Object ID

1.3.6.1.4.1.674.10893.1.20.130.13.1.13

Description

Identifies the revision number of the enclosure management
module.

Syntax

DisplayString

Access

Read-only

Enclosure Management Module Connection Table
This section describes the connection between each enclosure management
module on the managed system and its enclosure. Each enclosure number in
the table corresponds to that enclosure instance in the enclosure Table.
The following object sets up the Enclosure Management Module Connection
Table.
Name

enclosureManagementModuleConnectionTable

Object ID

1.3.6.1.4.1.674.10893.1.20.130.14

Description

Defines the enclosure memory module connection table.

Syntax

SEQUENCE OF EnclosureManagementModuleConnectionEntry

Access

Not accessible

Storage Management Group

657

Enclosure Management Module Connection Entry
Name

enclosureManagementModuleConnectionEntry

Object ID

1.3.6.1.4.1.674.10893.1.20.130.14.1

Description

Defines the enclosure memory module connection table entry.

Syntax

EnclosureManagementModuleConnectionEntry

Access

Not accessible

Index

enclosureManagementModuleConnectionNumber

Enclosure Management Module Connection Number
Name

enclosureManagementModuleConnectionNumber

Object ID

1.3.6.1.4.1.674.10893.1.20.130.14.1.1

Description

Identifies the instance number of the enclosure memory module
connection entry.

Syntax

Integer

Access

Read-only

Enclosure Management Module Connection EMM Name
Name

enclosureManagementModuleConnectionEMMName

Object ID

1.3.6.1.4.1.674.10893.1.20.130.14.1.2

Description

Identifies the name of the enclosure memory module in the
connection as represented in Storage Management.

Syntax

DisplayString

Access

Read-only

658

Storage Management Group

Enclosure Management Module Connection EMM Number
Name

enclosureManagementModuleConnectionEMMNumber

Object ID

1.3.6.1.4.1.674.10893.1.20.130.14.1.3

Description

Identifies the instance number in the
enclosureManagementModuleTable of the enclosure memory
module in the connection.

Syntax

Integer

Access

Read-only

Enclosure Management Module Connection Enclosure Name
Name

enclosureManagementModuleConnectionEnclosureName

Object ID

1.3.6.1.4.1.674.10893.1.20.130.14.1.4

Description

Identifies the name of the enclosure as represented in Storage
Management to which the enclosure memory module belongs.

Syntax

DisplayString

Access

Read-only

Enclosure Management Module Connection Enclosure Number
Name

enclosureManagementModuleConnectionEnclosure
Number

Object ID

1.3.6.1.4.1.674.10893.1.20.130.14.1.5

Description

Identifies the instance number of the enclosure in the
enclosureTable to which the enclosure memory module belongs.

Syntax

Integer

Access

Read-only

Storage Management Group

659

Battery Table
This section describes available properties for each controller battery on the
managed system.
The following object sets up the Battery Table.
Name

batteryTable

Object ID

1.3.6.1.4.1.674.10893.1.20.130.15

Description

Defines the battery table.

Syntax

SEQUENCE OF BatteryEntry

Access

Not accessible

Battery Entry
Name

batteryEntry

Object ID

1.3.6.1.4.1.674.10893.1.20.130.15.1

Description

Defines the battery table entry.

Syntax

BatteryEntry

Access

Not accessible

Index

batteryNumber

Battery Number
Name

batteryNumber

Object ID

1.3.6.1.4.1.674.10893.1.20.130.15.1.1

Description

Identifies the instance number of the battery entry.

Syntax

Integer

Access

Read-only

660

Storage Management Group

Battery Name
Name

batteryName

Object ID

1.3.6.1.4.1.674.10893.1.20.130.15.1.2

Description

Identifies the battery's name as represented in Storage
Management.

Syntax

DisplayString

Access

Read-only

Battery Vendor
Name

batteryVendor

Object ID

1.3.6.1.4.1.674.10893.1.20.130.15.1.3

Description

Identifies the battery's (re)seller's name.

Syntax

DisplayString

Access

Read-only

Battery State
Name

batteryState

Object ID

1.3.6.1.4.1.674.10893.1.20.130.15.1.4

Description

Identifies the current state of battery. Possible values:
0: Unknown
1: OK
2: Failed
6: Degraded
7: Reconditioning
9: High
10: Low
12: Charging
21: Missing
36: Learning

Syntax

Integer

Access

Read-only

Storage Management Group

661

Battery Roll-Up Status
Name

batteryRollUpStatus

Object ID

1.3.6.1.4.1.674.10893.1.20.130.15.1.5

Description

Identifies the severity of the battery state. This is the combined
status of the battery and its components. Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable

Syntax

DellStatus

Access

Read-only

Battery Component Status
Name

batteryComponentStatus

Object ID

1.3.6.1.4.1.674.10893.1.20.130.15.1.6

Description

Identifies the status of the battery itself without the propagation
of any contained component status. Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable

Syntax

DellStatus

Access

Read-only

662

Storage Management Group

Battery Charge Count
Name

batteryChargeCount

Object ID

1.3.6.1.4.1.674.10893.1.20.130.15.1.7

Description

Identifies the number of charges that have been applied to the
battery.

Syntax

Integer

Access

Read-only

Battery Max Charge Count
Name

batteryMaxChargeCount

Object ID

1.3.6.1.4.1.674.10893.1.20.130.15.1.8

Description

Identifies the maximum number of charges that can be applied to
the battery.

Syntax

Integer

Access

Read-only

Battery Nexus ID
Name

batteryNexusID

Object ID

1.3.6.1.4.1.674.10893.1.20.130.15.1.9

Description

Displays the durable unique ID for this EMM.

Syntax

DisplayString

Access

Read-only

Storage Management Group

663

Battery Predicted Capacity
Name

batteryPredictedCapacity

Object ID

1.3.6.1.4.1.674.10893.1.20.130.15.1.10

Description

Displays the battery's ability to be charged.
Possible values:
1: Failed - The battery cannot be charged and needs to be
replaced.
2: Ready - The battery can be charged to full capacity.
4: Unknown - The battery is completing a Learn cycle. The charge
capacity of the battery cannot be determined until the Learn cycle
is complete.

Syntax

Integer

Access

Read-only

Battery Next Learn Time
Name

batteryNextLearnTime

Object ID

1.3.6.1.4.1.674.10893.1.20.130.15.1.11

Description

Indicates the time (in hours) the next learn cycle must be
executed.

Syntax

Integer

Access

Read-only

664

Storage Management Group

Battery Learn State
Name

batteryLearnState

Object ID

1.3.6.1.4.1.674.10893.1.20.130.15.1.12

Description

Specifies the learn state activity of the battery.
Possible values:
1: Failed
2: Active
4: Timed out
8: Requested
16: Idle
32: Due

Syntax

Integer

Access

Read-only

Battery ID
Name

batteryID

Object ID

1.3.6.1.4.1.674.10893.1.20.130.15.1.13

Description

Represents the unique id for the battery.

Syntax

Integer

Access

Read-only

Battery Maximum Learn Delay
Name

batteryMaxLearnDelay

Object ID

1.3.6.1.4.1.674.10893.1.20.130.15.1.14

Description

The maximum amount of time (in hours) that the battery learn
cycle can be delayed.

Syntax

Integer

Access

Read-only

Storage Management Group

665

Battery Learn Mode
Name

batteryLearnMode

Object ID

1.3.6.1.4.1.674.10893.1.20.130.15.1.15

Description

Indicates the current learn mode of the battery.
Possible values:
1: Auto
2: Warn
4: Autowarn
8: Unknown

Syntax

Integer

Access

Read-only

666

Storage Management Group

Battery Connection Table
This section describes the connection between each controller battery on the
managed system and its controller. Each controller number in the table
corresponds to that controller instance in the controller Table.
The following object sets up the Battery Connection Table.
Name

batteryConnectionTable

Object ID

1.3.6.1.4.1.674.10893.1.20.130.16

Description

Defines the battery connection table.

Syntax

SEQUENCE OF BatteryConnectionEntry

Access

Not accessible

Battery Connection Entry
Name

batteryConnectionEntry

Object ID

1.3.6.1.4.1.674.10893.1.20.130.16.1

Description

Defines the battery connection table entry.

Syntax

BatteryConnectionEntry

Access

BatteryConnectionEntry

Index

BatteryConnectionNumber

Battery Connection Number
Name

batteryConnectionNumber

Object ID

1.3.6.1.4.1.674.10893.1.20.130.16.1.1

Description

Identifies the instance number of the battery connection entry.

Syntax

Integer

Access

Read-only

Storage Management Group

667

Battery Connection Battery Name
Name

batteryConnectionBatteryName

Object ID

1.3.6.1.4.1.674.10893.1.20.130.16.1.2

Description

Identifies the name of the battery in the connection as represented
in Storage Management.

Syntax

DisplayString

Access

Read-only

Battery Connection Battery Number
Name

batteryConnectionBatteryNumber

Object ID

1.3.6.1.4.1.674.10893.1.20.130.16.1.3

Description

Identifies the instance number in the batteryTable of the battery
in the connection.

Syntax

Integer

Access

Read-only

Battery Connection Controller Name
Name

batteryConnectionControllerName

Object ID

1.3.6.1.4.1.674.10893.1.20.130.16.1.4

Description

Identifies the name of the controller as represented in Storage
Management to which the battery belongs.

Syntax

DisplayString

Access

Read-only

Battery Connection Controller Number
Name

batteryConnectionControllerNumber

Object ID

1.3.6.1.4.1.674.10893.1.20.130.16.1.5

Description

Identifies instance number of the controller in the controllerTable
to which this battery belongs.

Syntax

Integer

Access

Read-only

668

Storage Management Group

Logical Devices Group
The Logical Devices Management Information Base (MIB) group provides
information about the logical devices managed by the Dell Storage
Management Software and their relationships to each other.
This group and all of its associated tables and objects are not supported on
Microsoft Windows Advanced Server Limited Edition 64-bit operating
system (Windows.Net-64) on a Dell PowerEdge 7150. The following MIB
tables define objects and relationships, or connections among the objects, in
the Logical Devices Group:
•

Virtual Disk Table—describes available properties for each virtual disk on
the managed system.

•

Array Disk Logical Connection Table—describes the connections
between array disks, the virtual disk to which they belong, and their
associated logical disk. For each object in the table, its object number
corresponds to an instance number in the appropriate MIB table for that
object where all of the object properties can be found.

Virtual Disk Table
This section describes available properties for each virtual disk on the
managed system.
The following object sets up the Virtual Disk Table.
Name

virtualDiskTable

Object ID

1.3.6.1.4.1.674.10893.1.20.140.1

Description

Defines the virtual disk table.

Syntax

SEQUENCE OF VirtualDiskEntry

Access

Not accessible

Storage Management Group

669

Virtual Disk Entry
Name

virtualDiskEntry

Object ID

1.3.6.1.4.1.674.10893.1.20.140.1.1

Description

Defines the virtual disk table entry.

Syntax

VirtualDiskEntry

Access

Not accessible

Index

virtualDiskNumber

Virtual Disk Number
Name

virtualDiskNumber

Object ID

1.3.6.1.4.1.674.10893.1.20.140.1.1.1

Description

Identifies the instance number of the virtual disk entry.

Syntax

Integer

Access

Read-only

Virtual Disk Name
Name

virtualDiskName

Object ID

1.3.6.1.4.1.674.10893.1.20.140.1.1.2

Description

Identifies the virtual disk's label generated by Storage
Management or entered by the user.

Syntax

DisplayString

Access

Read-only

Virtual Device Disk Name
Name

virtualDiskDeviceName

Object ID

1.3.6.1.4.1.674.10893.1.20.140.1.1.3

Description

Identifies the device name used by the virtual disk's member disks.

Syntax

DisplayString

Access

Read-only

670

Storage Management Group

Virtual Disk State
Name

virtualDiskState

Object ID

1.3.6.1.4.1.674.10893.1.20.140.1.1.4

Description

Identifies the current state of the virtual disk. Possible states:
0: Unknown
1: Ready - The disk is accessible and has no known problems.
2: Failed - The data on the virtual disk is no longer fault tolerant
because one of the underlying disks is not online.
3: Online
4: Offline - The disk is not accessible. The disk may be corrupted
or intermittently unavailable.
6: Degraded - The data on the virtual disk is no longer fault
tolerant because one of the underlying disks is not online.
15: Resynching
16: Regenerating
24: Rebuilding
26: Formatting
32: Reconstructing
35: Initializing
36: Background Initialization
38: Resynching Paused
52: Permanently Degraded
54: Degraded Redundancy

Syntax

Integer

Access

Read-only

Storage Management Group

671

Virtual Disk Severity
Name

virtualDiskSeverity

Object ID

1.3.6.1.4.1.674.10893.1.20.140.1.1.5

Description

This entry is obsolete for Storage Management. It is replaced with
RollUpStatus and ComponentStatus for each device.

Syntax

Integer

Access

Read-only

Virtual Disk Length in Megabytes
Name

virtualDiskLengthInMB

Object ID

1.3.6.1.4.1.674.10893.1.20.140.1.1.6

Description

Identifies the size of this virtual disk in megabytes. If the size is 0,
the size is smaller than a megabyte.

Syntax

Integer

Access

Read-only

Virtual Disk Length in Bytes
Name

virtualDiskLengthBytes

Object ID

1.3.6.1.4.1.674.10893.1.20.140.1.1.7

Description

Identifies the portion of the virtual disk in bytes that is smaller
than a megabyte. This size plus the virtualDiskLengthInMB is the
total size of the virtual disk.

Syntax

Integer

Access

Read-only

672

Storage Management Group

Virtual Disk Free Space in Megabytes
Name

virtualDiskFreeSpaceInMB

Object ID

1.3.6.1.4.1.674.10893.1.20.140.1.1.8

Description

This entry is obsolete. This property is not supported by virtual
disks managed under Storage Management.

Syntax

Integer

Access

Read-only

Virtual Disk Free Space in Bytes
Name

virtualDiskFreeSpaceInBytes

Object ID

1.3.6.1.4.1.674.10893.1.20.140.1.1.9

Description

This entry is obsolete. This property is not supported by virtual
disks managed under Storage Management.

Syntax

Integer

Access

Read-only

Virtual Disk Write Policy
Name

virtualDiskWritePolicy

Object ID

1.3.6.1.4.1.674.10893.1.20.140.1.1.10

Description

Indicates whether the controller's write cache is used when writing
to a virtual disk. Possible values:
1: Enabled - Adaptec Write Cache Enabled Protected
2: Disabled - Adaptec Write Cache Disabled
3: LSI Write Back
4: LSI Write Through
5: Enabled Always (Adaptec only)
6: Enabled Always (SAS only)
9: Not Applicable

Syntax

Integer

Access

Read-only

Storage Management Group

673

Virtual Disk Read Policy
Name

virtualDiskReadPolicy

Object ID

1.3.6.1.4.1.674.10893.1.20.140.1.1.11

Description

Indicates whether the controller's read cache is used when reading
from a virtual disk. Possible values:
1: Enabled - Adaptec Read Cache Enabled
2: Disabled - Adaptec Read Cache Disabled
3: LSI Read Ahead
4: LSI Adaptive Read Ahead
5: LSI No Read Ahead
9: Not Applicable

Syntax

Integer

Access

Read-only

Virtual Disk Cache Policy
Name

virtualDiskCachePolicy

Object ID

1.3.6.1.4.1.674.10893.1.20.140.1.1.12

Description

Indicates whether the controller's cache is used when reading from
or writing to a virtual disk. Possible values:
1: Direct I/O (LSI)
2: Cached I/O (LSI)
99: Not Applicable

Syntax

Integer

Access

Read-only

674

Storage Management Group

Virtual Disk Layout
Name

virtualDiskLayout

Object ID

1.3.6.1.4.1.674.10893.1.20.140.1.1.13

Description

Indicates the virtual disk's RAID type. Possible values:
1: Concatenated
2: RAID-0
3: RAID-1
7: RAID-5
8: RAID-6
10: RAID-10
12: RAID-50
19: Concatenated RAID 1
24: RAID-60
25: CacheCade

Syntax

Integer

Access

Read-only

Virtual Disk Current Stripe Size in Megabytes
Name

virtualDiskCurStripeSizeInMB

Object ID

1.3.6.1.4.1.674.10893.1.20.140.1.1.14

Description

Identifies the stripe size of the virtual disk in megabytes. If this
size is 0, the stripe size is smaller than a megabyte.

Syntax

Integer

Access

Read-only

Storage Management Group

675

Virtual Disk Current Stripe Size in Bytes
Name

virtualDiskCurStripeSizeInBytes

Object ID

1.3.6.1.4.1.674.10893.1.20.140.1.1.15

Description

Identifies the portion of the stripe size in bytes that is smaller than
a megabyte. This size plus the virtualDiskCurStripeSizeInMB is
the total stripe size on the virtual disk.

Syntax

Integer

Access

Read-only

Virtual Disk Channel
Name

virtualDiskChannel

Object ID

1.3.6.1.4.1.674.10893.1.20.140.1.1.16

Description

This entry is obsolete. This property is not supported by virtual
disks managed under Storage Management.

Syntax

Integer

Access

Read-only

Virtual Disk Target ID
Name

virtualDiskTargetID

Object ID

1.3.6.1.4.1.674.10893.1.20.140.1.1.17

Description

Displays the unique ID for the virtual disk.

Syntax

Integer

Access

Read-only

Virtual Disk LUN ID
Name

virtualDiskLunID

Object ID

1.3.6.1.4.1.674.10893.1.20.140.1.1.18

Description

This entry is obsolete. This property is not supported by virtual
disks managed under Storage Management.

Syntax

Integer

Access

Read-only

676

Storage Management Group

Virtual Disk Roll-Up Status
Name

virtualDiskRollUpStatus

Object ID

1.3.6.1.4.1.674.10893.1.20.140.1.1.19

Description

Identifies the severity of the virtual disk state. This is the
combined status of the virtual disk and its components. Possible
values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable

Syntax

DellStatus

Access

Read-only

Virtual Disk Component Status
Name

virtualDiskComponentStatus

Object ID

1.3.6.1.4.1.674.10893.1.20.140.1.1.20

Description

Displays the status of the virtual disk itself without the
propagation of any contained component status. Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable

Syntax

DellStatus

Access

Read-only

Storage Management Group

677

Virtual Disk Nexus ID
Name

virtualDiskNexusID

Object ID

1.3.6.1.4.1.674.10893.1.20.140.1.1.21

Description

Displays the durable unique ID for the virtual disk.

Syntax

DisplayString

Access

Read-only

Virtual Disk Array Disk Type
Name

virtualDiskArrayDiskType

Object ID

1.3.6.1.4.1.674.10893.1.20.140.1.1.22

Description

Identifies the type of array (physical) disks used to create the
virtual disk.
Possible values:
1: SAS
2: SATA
3: SCSI
4: IDE
99: Unknown

Syntax

Integer

Access

Read-only

Virtual Disk Bad Blocks Detected
Name

virtualDiskBadBlocksDetected

Object ID

1.3.6.1.4.1.674.10893.1.20.140.1.1.23

Description

Indicates if virtual disk has bad blocks.
Possible values:
0 - No
1 - Yes
2 - Not Applicable
99 - Unknown

678

Storage Management Group

Name

virtualDiskBadBlocksDetected

Syntax

Integer

Access

Read-only

Virtual Disk Encrypted
Name

virtualDiskEncrypted

Object ID

1.3.6.1.4.1.674.10893.1.20.140.1.1.24

Description

Indicates if virtual disk is encrypted.
Possible values:
0 - No
1 - Yes
99 - Unknown

Syntax

Integer

Access

Read-only

Virtual Disk is CacheCade
Name

virtualDiskIsCacheCade

Object ID

1.3.6.1.4.1.674.10893.1.20.140.1.1.25

Description

Indicates if this virtual disk is configured as CacheCade.
Possible values:
1 - Yes
0 - No
99 - Undetermined

Syntax

Integer

Access

Read-only

Virtual Disk Disk Cache Policy
Name

virtualDiskDiskCachePolicy

Object ID

1.3.6.1.4.1.674.10893.1.20.140.1.1.26

Storage Management Group

679

Name

virtualDiskDiskCachePolicy

Description

Indicates disk cache policy of the logical device.
Value: 1 - Enabled, 2 - Disabled, 99 - Undetermined

Syntax

Integer

Access

Read-only

Array Disk Logical Connection Table
This section describes the connections between array disks, the virtual disk to
which they belong, and their associated logical disk. For each object in the
table, its object number corresponds to an instance number in the
appropriate MIB table for that object where all of the object properties can be
found.
The following object sets up the Array Disk Logical Connection Table.
Name

arrayDiskLogicalConnectionTable

Object ID

1.3.6.1.4.1.674.10893.1.20.140.3

Description

Defines the array disk logical connection table.

Syntax

SEQUENCE OF arrayDiskLogicalConnectionEntry

Access

Not accessible

Array Disk Logical Connection Entry
Name

arrayDiskLogicalConnectionEntry

Object ID

1.3.6.1.4.1.674.10893.1.20.140.3.1

Description

Defines the array disk logical connection table entry.

Syntax

ArrayDiskLogicalConnectionEntry

Access

Not accessible

Index

arrayDiskLogicalConnectionNumber

Array Disk Logical Connection Number
Name

arrayDiskLogicalConnectionNumber

Object ID

1.3.6.1.4.1.674.10893.1.20.140.3.1.1

680

Storage Management Group

Name

arrayDiskLogicalConnectionNumber

Description

Identifies the instance number of the disk entry.

Syntax

Integer

Access

Read-only

Array Disk Logical Connection Array Disk Name
Name

arrayDiskLogicalConnectionArrayDiskName

Object ID

1.3.6.1.4.1.674.10893.1.20.140.3.1.2

Description

Identifies the name of the array disk in the logical connection.

Syntax

DisplayString

Access

Read-only

Array Disk Logical Connection Array Disk Number
Name

arrayDiskLogicalConnectionArrayDiskNumber

Object ID

1.3.6.1.4.1.674.10893.1.20.140.3.1.3

Description

Identifies the instance number of the array disk in the logical
connection.

Syntax

Integer

Access

Read-only

Array Disk Logical Connection Virtual Disk Name
Name

arrayDiskLogicalConnectionVirtualDiskName

Object ID

1.3.6.1.4.1.674.10893.1.20.140.3.1.4

Description

Identifies the name of the virtual disk to which the array disk
belongs.

Syntax

DisplayString

Access

Read-only

Storage Management Group

681

Array Disk Logical Connection Virtual Disk Number
Name

arrayDiskLogicalConnectionVirtualDiskNumber

Object ID

1.3.6.1.4.1.674.10893.1.20.140.3.1.5

Description

Identifies the instance number of the virtual disk to which the
array disk belongs.

Syntax

Integer

Access

Read-only

Array Disk Logical Connection Disk Name
Name

arrayDiskLogicalConnectionDiskName

Object ID

1.3.6.1.4.1.674.10893.1.20.140.3.1.6

Description

Identifies the name of the disk group to which the array disk
belongs.

NOTE: This property is currently not supported.
Syntax

DisplayString

Access

Read-only

Array Disk Logical Connection Disk Number
Name

arrayDiskLogicalConnectionDiskNumber

Object ID

1.3.6.1.4.1.674.10893.1.20.140.3.1.7

Description

Identifies the instance number of the disk group to which the
array disk belongs.

NOTE: This property is currently not supported.
Syntax

Integer

Access

Read-only

Storage Management Event Group
The Storage Management Event Group defines the properties that are sent
with SNMP traps.

682

Storage Management Group

Message ID Event
Name

messageIDEvent

Object ID

1.3.6.1.4.1.674.10893.1.20.200.1

Description

Displays the Storage Management event message number.

Syntax

Integer

Access

Read-only

Description Event
Name

descriptionEvent

Object ID

1.3.6.1.4.1.674.10893.1.20.200.2

Description

Displays the Storage Management event message text describing
the alert.

Syntax

DisplayString

Access

Read-only

Location Event
Name

locationEvent

Object ID

1.3.6.1.4.1.674.10893.1.20.200.3

Description

Displays the additional information identifying the location of the
object causing the alert.

Syntax

DisplayString

Access

Read-only

Object Name Event
Name

objectNameEvent

Object ID

1.3.6.1.4.1.674.10893.1.20.200.4

Description

Displays the name of the object as represented in Storage
Management causing the alert.

Syntax

DisplayString

Access

Read-only

Storage Management Group

683

Object OID Event
Name

objectOIDEvent

Object ID

1.3.6.1.4.1.674.10893.1.20.200.5

Description

Displays the MIB OID of the object causing the alert.

Syntax

DisplayString

Access

Read-only

Object Nexus Event
Name

objectNexusEvent

Object ID

1.3.6.1.4.1.674.10893.1.20.200.6

Description

Displays the durable, unique ID of the object causing the alert.

Syntax

DisplayString

Access

Read-only

Current Status Event
Name

currentStatusEvent

Object ID

1.3.6.1.4.1.674.10893.1.20.200.7

Description

Displays the current status of object causing the alert, if
applicable.

Syntax

DellStatus

Access

Read-only

Previous Status Event
Name

previousStatusEvent

Object ID

1.3.6.1.4.1.674.10893.1.20.200.8

Description

Displays the previous status of the object causing the alert, if
applicable.

Syntax

DellStatus

Access

Read-only

684

Storage Management Group

Change Management Group

25

The Change Management Group lets you monitor information about the
Dell devices and software that are present on a particular managed computer
chassis. This information is collected during an inventory scan.

Inventory Group
The following objects describe the fields for inventory information.
Inventory Locale
Name

inventoryLocale

Object ID

1.3.6.1.4.1.674.10899.1.1

Description

Defines the locale of the system.

Syntax

DisplayString

Access

Read-only

Inventory Schema Version
Name

inventorySchemaVersion

Object ID

1.3.6.1.4.1.674.10899.1.2

Description

Defines the inventory schema implemented by this system.

Syntax

DisplayString

Access

Read-only

Inventory System ID
Name

inventorySystemID

Object ID

1.3.6.1.4.1.674.10899.1.3

Description

Defines the System ID for the system.

Syntax

SystemID

Change Management Group

685

Name

inventorySystemID

Access

Read-only

Device Group
The Device Group defines information about the devices discovered on the
system during an inventory scan. Identifying information includes the
Component ID, the Device ID, and the Vendor ID.

Device Group Table
The following object sets up the Device Group Table.
Name

deviceTable

Object ID

1.3.6.1.4.1.674.10899.1.5

Description

Defines the Device Table.

Syntax

SEQUENCE OF DeviceEntry

Access

Not accessible

Device Entry
Name

deviceEntry

Object ID

1.3.6.1.4.1.674.10899.1.5.1

Description

Defines a device entry.

Syntax

DeviceEntry

Access

Not accessible

Device Index
Name

deviceIndex

Object ID

1.3.6.1.4.1.674.10899.1.5.1.1

Description

Defines the unique index for this device.

Syntax

Unsigned16BitRange

Access

Read-only

686

Change Management Group

Device Component ID
Name

deviceComponentID

Object ID

1.3.6.1.4.1.674.10899.1.5.1.2

Description

Defines an optional component ID field for the device.

Syntax

Integer

Access

Read-only

Device Display String
Name

deviceDisplayString

Object ID

1.3.6.1.4.1.674.10899.1.5.1.3

Description

Provides a displayable string that describes the device.

Syntax

DisplayString

Access

Read-only

Device Vendor ID
Name

deviceVendorID

Object ID

1.3.6.1.4.1.674.10899.1.5.1.4

Description

Defines the ID for the vendor supplying the device.

Syntax

Octet String

Access

Read-only

Device ID
Name

deviceDeviceID

Object ID

1.3.6.1.4.1.674.10899.1.5.1.5

Description

Defines the ID for the device.

Syntax

Octet String

Access

Read-only

Change Management Group

687

Device Sub ID
Name

deviceSubID

Object ID

1.3.6.1.4.1.674.10899.1.5.1.6

Description

Provides additional device identification.

Syntax

Octet String

Access

Read-only

Device Sub Vendor ID
Name

deviceSubVendorID

Object ID

1.3.6.1.4.1.674.10899.1.5.1.7

Description

Provides additional vendor identification.

Syntax

Octet String

Access

Read-only

Application Group
NOTE: Dell updateable components such as Basic input/output system (BIOS) and
FirmWare (FW) are considered applications. For example, the following would be
returned for system BIOS: Application/DisplayString = BIOS
Application/Version = A10
The Application Group defines information about the applications
discovered on the system during an inventory scan. Identifying information
includes the application type, the application version, and the application
description.

688

Change Management Group

Application Group Table
The following object sets up the Application Group Table.
Name

applicationTable

Object ID

1.3.6.1.4.1.674.10899.1.6

Description

Defines a table of application information for the system.

Syntax

SEQUENCE OF ApplicationEntry

Access

Not accessible

Application Entry
Name

applicationEntry

Object ID

1.3.6.1.4.1.674.10899.1.6.1

Description

Defines an application entry.

Syntax

ApplicationEntry

Access

Read-only

Application Index
Name

applicationIndex

Object ID

1.3.6.1.4.1.674.10899.1.6.1.1

Description

Defines the unique index for this application.

Syntax

Unsigned16BitRange

Access

Read-only

Application Device Index
Name

applicationDeviceIndex

Object ID

1.3.6.1.4.1.674.10899.1.6.1.2

Description

Defines a cross-index to the device table for the application.

Syntax

Unsigned16BitRange

Access

Read-only

Change Management Group

689

Application Component Type
Name

applicationComponentType

Object ID

1.3.6.1.4.1.674.10899.1.6.1.3

Description

Identifies the type of application reported.

Syntax

DisplayString

Access

Read-only

Application Version
Name

applicationVersion

Object ID

1.3.6.1.4.1.674.10899.1.6.1.4

Description

Identifies the version of the application.

Syntax

DisplayString

Access

Read-only

Application Display String
Name

applicationDisplayString

Object ID

1.3.6.1.4.1.674.10899.1.6.1.5

Description

A user visible display string that describes the application.

Syntax

DisplayString

Access

Read-only

Application Sub-Component ID
Name

applicationSubComponentID

Object ID

1.3.6.1.4.1.674.10899.1.6.1.6

Description

The sub-component ID for the application. This is usually valid
on ESM device reporting.

Syntax

DisplayString

Access

Read-only

690

Change Management Group

Operating System Group
The Operating System Group provides status and identifying information about
a system’s operating system. Identifying information includes the name,
version, and service pack of the installed operating system.
The following objects describe the fields for Operating System Group.
Operating System Vendor
Name

operatingSystemVendor

Object ID

1.3.6.1.4.1.674.10899.2.1

Description

Defines the vendor of the Operating System.

Syntax

DisplayString

Access

Read-only

Operating System Major Version
Name

operatingSystemMajorVersion

Object ID

1.3.6.1.4.1.674.10899.2.2

Description

Defines the major version of the Operating System.

Syntax

DisplayString

Access

Read-only

Operating System Minor Version
Name

operatingSystemMinorVersion

Object ID

1.3.6.1.4.1.674.10899.2.3

Description

Defines the minor version of the Operating System.

Syntax

DisplayString

Access

Read-only

Change Management Group

691

Operating System Service Pack Major Version
Name

operatingSystemSPMajorVersion

Object ID

1.3.6.1.4.1.674.10899.2.5

Description

Defines the Operating System's Service Pack major version.

Syntax

DisplayString

Access

Read-only

Operating System Service Pack Minor Version
Name

operatingSystemSPMinorVersion

Object ID

1.3.6.1.4.1.674.10899.2.6

Description

Defines the Operating System's Service Pack minor version.

Syntax

DisplayString

Access

Read-only

Operating System Architecture
Name

operatingSystemArchitecture

Object ID

1.3.6.1.4.1.674.10899.2.7

Description

Defines the Operating System's architecture.

Syntax

DisplayString

Access

Read-only

Inventory Collector Product Information
The following objects describe the fields for the Inventory Collector. The
Inventory Collector product variables are scalar objects, meaning that they
are not related to other Inventory Collector base (MIB) objects and are thus
not placed in a table.

692

Change Management Group

Product ID Display Name
Name

productIDDisplayName

Object ID

1.3.6.1.4.1.674.10899.100.1

Description

Defines the display name of the product.

Syntax

DisplayString

Access

Read-only

Product ID Description
Name

productIDDescription

Object ID

1.3.6.1.4.1.674.10899.100.2

Description

Provides a description of the product.

Syntax

DisplayString

Access

Read-only

Product ID Vendor
Name

productIDVendor

Object ID

1.3.6.1.4.1.674.10899.100.3

Description

Provides name of the manufacturer of the product.

Syntax

DisplayString

Access

Read-only

Product ID Version
Name

productIDVersion

Object ID

1.3.6.1.4.1.674.10899.100.4

Description

Describes the version of the product.

Syntax

DisplayString

Access

Read-only

Change Management Group

693

Product ID Build Number
Name

productIDBuildNumber

Object ID

1.3.6.1.4.1.674.10899.100.5

Description

Describes the software build number of the product.

Syntax

DisplayString

Access

Read-only

694

Change Management Group

26

Dell Remote Access Controller Outof-Band Group
The Dell Remote Access Controller Out-of-Band MIB contains information
for both Chassis Management Controller (CMC) and RAC Legacy Alerting.
This MIB consists of information for the following groups:

Product Information
The following MIB tables define the Dell RAC Out-of-Band group:

DRsProductName
Name

DRsProductName

Object ID

1.3.6.1.4.1.674.10892.2.1.1.1

Description

Defines the product name of a chassis management controller.

Syntax

DellString

Access

Read-only

DRsProductShortName
Name

DRsProductShortName

Object ID

1.3.6.1.4.1.674.10892.2.1.1.2

Description

Defines the short product name of a chassis management controller.

Syntax

DellString

Access

Read-only

Dell Remote Access Controller Out-of-Band Group

695

DRsProductDescription
Name

DRsProductDescription

Object ID

1.3.6.1.4.1.674.10892.2.1.1.3

Description

Defines the product description of a chassis management controller.

Syntax

DellString

Access

Read-only

DRsProductManufacturer
Name

DRsProductManufacturer

Object ID

1.3.6.1.4.1.674.10892.2.1.1.4

Description

Defines the product manufacturer of a chassis management
controller.

Syntax

DellString

Access

Read-only

DRsProductVersion
Name

DRsProductVersion

Object ID

1.3.6.1.4.1.674.10892.2.1.1.5

Description

Defines the product version of a chassis management controller.

Syntax

DellString

Access

Read-only

DRsChassisServiceTag
Name

DRsChassisServiceTag

Object ID

1.3.6.1.4.1.674.10892.2.1.1.6

Description

Defines the Service Tag of the chassis.

Syntax

DellString

Access

Read-only

696

Dell Remote Access Controller Out-of-Band Group

DRsProductURL
Name

DrsProductURL

Object ID

1.3.6.1.4.1.674.10892.2.1.1.7

Description

Defines the out-of-band UI URL of a chassis management
controller.

Syntax

DellString

Access

Read-only

DRsProductChassisAssetTag
Name

DRsProductChassisAssetTag

Object ID

1.3.6.1.4.1.674.10892.2.1.1.8

Description

Defines the Asset Tag of the chassis.

Syntax

DellString

Access

Read-only

DRsProductChassisLocation
Name

DRsProductChassisLocation

Object ID

1.3.6.1.4.1.674.10892.2.1.1.9

Description

Defines the location of the chassis.

Syntax

DellString

Access

Read-only

DRsProductChassisName
Name

DrsProductChassisName

Object ID

1.3.6.1.4.1.674.10892.2.1.1.10

Description

Defines the name of the chassis.

Syntax

DellString

Access

Read-only

Dell Remote Access Controller Out-of-Band Group

697

DRsSystemServiceTag
Name

DRsSystemServiceTag

Object ID

1.3.6.1.4.1.674.10892.2.1.1.11

Description

Defines the service tag of a system.

Syntax

DellString

Access

Read-only

DRsProductSystemAssetTag
Name

DRsProductSystemAssetTag

Object ID

1.3.6.1.4.1.674.10892.2.1.1.12

Description

Defines the asset tag of a system.

Syntax

DellString

Access

Read-only

DRsProductSystemSlot
Name

DRsProductSystemSlot

Object ID

1.3.6.1.4.1.674.10892.2.1.1.13

Description

Defines the slot number of a CMC.

Syntax

DellString

Access

Read-only

DRsProductType
Name

DRsProductType

Object ID

1.3.6.1.4.1.674.10892.2.1.1.14

Description

Defines type of a remote access card.

Syntax

DellRacType

Access

Read-only

698

Dell Remote Access Controller Out-of-Band Group

DRsFirmwareVersion
Name

DRsFirmwareVersion

Object ID

1.3.6.1.4.1.674.10892.2.1.2.1

Description

Defines the firmware version of a chassis management controller.

Syntax

DellString

Access

Read-only

Chassis Status
The following MIB tables provide information on Chassis being monitored by
the chassis management card.

DRsGlobalSystemStatus
Name

DRsGlobalSystemStatus

Object ID

1.3.6.1.4.1.674.10892.2.2.1

Description

Defines the overall chassis status being monitored by the chassis
management card.

Syntax

DellStatus

Access

Read-only

DRsGlobalCurrStatus
Name

DRsGlobalCurrStatus

Object ID

1.3.6.1.4.1.674.10892.2.3.1.1

Description

Defines the overall chassis status being monitored by the chassis
management card.

Syntax

DellStatus

Access

Read-only

Dell Remote Access Controller Out-of-Band Group

699

DRsIOMCurrStatus
Name

DRsIOMCurrStatus

Object ID

1.3.6.1.4.1.674.10892.2.3.1.2

Description

Defines the IOM subsystem status being monitored by the chassis
management card.

Syntax

DellStatus

Access

Read-only

DRsKVMCurrStatus
Name

DRsKVMCurrStatus

Object ID

1.3.6.1.4.1.674.10892.2.3.1.3

Description

Defines the iKVM subsystem health status being monitored by the
chassis management card.

Syntax

DellStatus

Access

Read-only

DRsRedCurrStatus
Name

DRsRedCurrtatus

Object ID

1.3.6.1.4.1.674.10892.2.3.1.4

Description

Defines the redundancy status being monitored by the chassis
management card.

Syntax

DellStatus

Access

Read-only

700

Dell Remote Access Controller Out-of-Band Group

DRsPowerCurrStatus
Name

DRsPowerCurrStatus

Object ID

1.3.6.1.4.1.674.10892.2.3.1.5

Description

Defines the power subsystem health status being monitored by the
chassis management card.

Syntax

DellStatus

Access

Read-only

DRsFanCurrStatus
Name

DRsFanCurrStatus

Object ID

1.3.6.1.4.1.674.10892.2.3.1.6

Description

Defines the fan subsystem health status being monitored by the
chassis management card.

Syntax

DellStatus

Access

Read-only

DRsBladeCurrStatus
Name

DRsBladeCurrStatus

Object ID

1.3.6.1.4.1.674.10892.2.3.1.7

Description

Defines the blade subsystem health status being monitored by the
chassis management card.

Syntax

DellStatus

Access

Read-only

Dell Remote Access Controller Out-of-Band Group

701

DRsTempCurrStatus
Name

DRsTempCurrStatus

Object ID

1.3.6.1.4.1.674.10892.2.3.1.8

Description

Defines the temperature sensor subsystem health status being
monitored by the chassis management card.

Syntax

DellStatus

Access

Read-only

DRsCMCCurrStatus
Name

DRsCMCCurrStatus

Object ID

1.3.6.1.4.1.674.10892.2.3.1.9

Description

Defines the CMC health status being monitored by the chassis
management card.

Syntax

DellStatus

Access

Read-only

DRsChassisFrontPanelAmbientTemperature
Name

drsChassisFrontPanelAmbientTemperature

Object ID

1.3.6.1.4.1.674.10892.2.3.1.10

Description

Defines the ambient temperature reading (in degrees Celsius) for
the chassis front panel controller.

Syntax

DellTemperatureReading

Access

Read-only

702

Dell Remote Access Controller Out-of-Band Group

DRsCMAmbientTemperature
Name

drsCMCAmbientTemperature

Object ID

1.3.6.1.4.1.674.10892.2.3.1.11

Description

Defines the ambient temperature reading (in degrees Celsius) for
the chassis management card.

Syntax

DellTemperatureReading

Access

Read-only

DRsCMProcessorTemperature
Name

drsCMCProcessorTemperature

Object ID

1.3.6.1.4.1.674.10892.2.3.1.12

Description

Defines the temperature reading (in degrees Celsius) for the chassis
management card. processor.

Syntax

DellTemperatureReading

Access

Read-only

DRsGlobalPrevStatus
Name

DRsGlobalPrevStatus

Object ID

1.3.6.1.4.1.674.10892.2.3.2.1

Description

Defines the previous chassis status recorded by the chassis
management card.

Syntax

DellStatus

Access

Read-only

Dell Remote Access Controller Out-of-Band Group

703

DRsIOMPrevStatus
Name

DRsIOMPrevStatus

Object ID

1.3.6.1.4.1.674.10892.2.3.2.2

Description

Defines the previous IOM subsystem status recorded by the chassis
management card.

Syntax

DellStatus

Access

Read-only

DRsKVMPrevStatus
Name

DRsKVMPrevStatus

Object ID

1.3.6.1.4.1.674.10892.2.3.2.3

Description

Defines the previous iKVM subsystem health status recorded by the
chassis management card.

Syntax

DellStatus

Access

Read-only

DRsRedPrevStatus
Name

DRsRedPrevStatus

Object ID

1.3.6.1.4.1.674.10892.2.3.2.4

Description

Defines the previous redundancy status recorded by the chassis
management card.

Syntax

DellStatus

Access

Read-only

704

Dell Remote Access Controller Out-of-Band Group

DRsPowerPrevStatus
Name

DRsPowerPrevStatus

Object ID

1.3.6.1.4.1.674.10892.2.3.2.5

Description

Defines the previous power subsystem health status recorded by the
chassis management card.

Syntax

DellStatus

Access

Read-only

DRsFanPrevStatus
Name

DrsFanPrevStatus

Object ID

1.3.6.1.4.1.674.10892.2.3.2.6

Description

Defines the previous fan health status being monitored by the
chassis management card.

Syntax

DellStatus

Access

Read-only

DRsBladePrevStatus
Name

DRsBladePrevStatus

Object ID

1.3.6.1.4.1.674.10892.2.3.2.7

Description

Defines the previous blade subsystem health status recorded by the
chassis management card.

Syntax

DellStatus

Access

Read-only

Dell Remote Access Controller Out-of-Band Group

705

DRsTempPrevStatus
Name

DRsTempPrevStatus

Object ID

1.3.6.1.4.1.674.10892.2.3.2.8

Description

Defines the temperature sensor health status being monitored by
the chassis management card.

Syntax

DellStatus

Access

Read-only

DRsCMCPrevStatus
Name

DRsCMCPrevStatus

Object ID

1.3.6.1.4.1.674.10892.2.3.2.9

Description

Defines the CMC health status being monitored by the chassis
management card.

Syntax

DellStatus

Access

Read-only

DRsGlobalChangeTime
Name

DRsGlobalChangeTime

Object ID

1.3.6.1.4.1.674.10892.2.3.3.1

Description

Defines the timestamp of the most recent global status change.

Syntax

TimeTicks

Access

Read-only

DRsIOMChangeTime
Name

DRsIOMChangeTime

Object ID

1.3.6.1.4.1.674.10892.2.3.3.2

Description

Defines the timestamp of the most recent IOM status change.

Syntax

TimeTicks

Access

Read-only

706

Dell Remote Access Controller Out-of-Band Group

DRsKVMChangeTime
Name

DRsKVMChangeTime

Object ID

1.3.6.1.4.1.674.10892.2.3.3.3

Description

Defines the timestamp of the most recent iKVM status change.

Syntax

TimeTicks

Access

Read-only

DRsRedChangeTime
Name

DRsRedChangeTime

Object ID

1.3.6.1.4.1.674.10892.2.3.3.4

Description

Defines the timestamp of the most recent Redundancy status
change.

Syntax

TimeTicks

Access

Read-only

DRsPowerChangeTime
Name

DRsPowerChangeTime

Object ID

1.3.6.1.4.1.674.10892.2.3.3.5

Description

Defines the timestamp of the most recent power health status
change.

Syntax

TimeTicks

Access

Read-only

DRsFanChangeTime
Name

DRsFanChangeTime

Object ID

1.3.6.1.4.1.674.10892.2.3.3.6

Description

Defines the timestamp of the most recent fan health status change.

Syntax

TimeTicks

Access

Read-only

Dell Remote Access Controller Out-of-Band Group

707

DRsBladeChangeTime
Name

DRsBladeChangeTime

Object ID

1.3.6.1.4.1.674.10892.2.3.3.7

Description

Defines the timestamp of the most recent blade health status
change.

Syntax

TimeTicks

Access

Read-only

DRsTempChangeTime
Name

DRsTempChangeTime

Object ID

1.3.6.1.4.1.674.10892.2.3.3.8

Description

Defines the timestamp of the most recent temperature sensor
health status change.

Syntax

TimeTicks

Access

Read-only

DRsCMCChangeTime
Name

DRsCMCChangeTime

Object ID

1.3.6.1.4.1.674.10892.2.3.3.9

Description

Defines the timestamp of the most recent CMC health status
change.

Syntax

TimeTicks

Access

Read-only

708

Dell Remote Access Controller Out-of-Band Group

Chassis Power
The following MIB tables provide information on the chassis management
controller table entry.

DRsCMC Power Table
Name

DRsCMCPowerTable

Object ID

1.3.6.1.4.1.674.10892.2.4.1

Description

Defines the CMC power table.

Syntax

SEQUENCE OF DrsCMCPowerTableEntry

Access

Not-accessible

DRsCMC Power Table Entry
Name

DRsCMCPowerTableEntry

Object ID

1.3.6.1.4.1.674.10892.2.4.1.1

Description

Defines the CMC power table entry.

Syntax

DrsCMCPowerTableEntry

Access

Not-accessible

DRsCMC PSUTable
Name

DrsCMCPSUTable

Object ID

1.3.6.1.4.1.674.10892.2.4.2

Description

Defines the CMC PSU table.

Syntax

SEQUENCE OF DrsCMCPSUTableEntry

Access

Not-accessible

Dell Remote Access Controller Out-of-Band Group

709

DRsCMC PSUTableEntry
Name

DrsCMCPSUTableEntry

Object ID

1.3.6.1.4.1.674.10892.2.4.2.1

Description

Defines the CMC PSU table entry.

Syntax

DrsCMCPSUTableEntry

Access

Not-accessible

CMC Power Information
The following MIB tables provide information on the chassis power.

DRsChassisIndex
Name

DrsChassisIndex

Object ID

1.3.6.1.4.1.674.10892.2.4.1.1.1

Description

Defines the index (one-based) of the associated chassis.

Syntax

DellCMCPowerIndexRange

Access

Read-only

DRsPotentialPower
Name

DRsPotentialPower

Object ID

1.3.6.1.4.1.674.10892.2.4.1.1.2

Description

Defines the power (in Watts) required by the chassis infrastructure,
plus the sum of the maximum power requirements for all systems
currently turned on.

Syntax

DellPowerReading

Access

Read-only

710

Dell Remote Access Controller Out-of-Band Group

DRsIdlePower
Name

DRsIdlePower

Object ID

1.3.6.1.4.1.674.10892.2.4.1.1.3

Description

Defines the power (in Watts) required by the chassisinfrastructure,
plus the sum of the minimum power requirements for all systems
currently turned on.

Syntax

DellPowerReading

Access

Read-only

DRsMaxPowerSpecification
Name

DRsMaxPowerSpecification

Object ID

1.3.6.1.4.1.674.10892.2.4.1.1.4

Description

Defines the power limit (in Watts) at which server throttling takes
place.

Syntax

DellPowerReading

Access

Read-only

DRsPowerSurplus
Name

DRsPowerSurplus

Object ID

1.3.6.1.4.1.674.10892.2.4.1.1.5

Description

Defines the power surplus (in Watts) remaining above the
drsPotentialPower reading.

Syntax

DellPowerReading

Access

Read-only

Dell Remote Access Controller Out-of-Band Group

711

DRsKWhCumulative
Name

DRsKWhCumulative

Object ID

1.3.6.1.4.1.674.10892.2.4.1.1.6

Description

Defines the cumulative chassis power usage (in KWh) since last
reset.

Syntax

DellPowerReading

Access

Read-only

DRsKWhCumulativeTime
Name

DRsKWhCumulativeTime

Object ID

1.3.6.1.4.1.674.10892.2.4.1.1.7

Description

Defines the timestamp of the most recent chassis power
accumulator reset.

Syntax

DellTimestamp

Access

Read-only

DRsWattsPeakUsage
Name

DRsWattsPeakUsage

Object ID

1.3.6.1.4.1.674.10892.2.4.1.1.8

Description

Defines the chassis peak power usage (in Watts) since last reset.

Syntax

DellPowerReading

Access

Read-only

DRsWattsPeakTime
Name

DRsWattsPeakTime

Object ID

1.3.6.1.4.1.674.10892.2.4.1.1.9

Description

Defines the timestamp of the most recent chassis peak power usage.

Syntax

DellTimestamp

Access

Read-only

712

Dell Remote Access Controller Out-of-Band Group

DRsWattsMinUsage
Name

DRsWattsMinUsage

Object ID

1.3.6.1.4.1.674.10892.2.4.1.1.10

Description

Defines the chassis minimum power usage (in Watts) since last
reset.

Syntax

DellPowerReading

Access

Read-only

DRsWattsMinTime
Name

DRsWattsMinTime

Object ID

1.3.6.1.4.1.674.10892.2.4.1.1.11

Description

Defines the timestamp of the most recent chassis minimum power
usage.

Syntax

DellPowerReading

Access

Read-only

DRsWattsResetTime
Name

DRsWattsResetTime

Object ID

1.3.6.1.4.1.674.10892.2.4.1.1.12

Description

Defines the timestamp of the most recent reset of the chassis
minimum/maximum Watts readings.

Syntax

DellTimestamp

Access

Read-only

Dell Remote Access Controller Out-of-Band Group

713

DRsWattsReading
Name

DRsWattsReading

Object ID

1.3.6.1.4.1.674.10892.2.4.1.1.13

Description

Defines the instantaneous chassis power usage (in Watts)

Syntax

DellPowerReading

Access

Read-only

DRsAmpsReading
Name

DRsAmpsReading

Object ID

1.3.6.1.4.1.674.10892.2.4.1.1.14

Description

Defines the instantaneous chassis current usage (in Watts).

Syntax

DellPowerReading

Access

Read-only

CMC PSU Information
The following MIB tables provide information on the chassis power
supply unit.

DRsPSUChassisIndex
Name

DRsPSUChassisIndex

Object ID

1.3.6.1.4.1.674.10892.2.4.2.1.1

Description

Defines the index (one-based) of the associated chassis.

Syntax

DellCMCPowerIndexRange

Access

Read-only

714

Dell Remote Access Controller Out-of-Band Group

DRsPSUIndex
Name

DRsPSUIndex

Object ID

1.3.6.1.4.1.674.10892.2.4.2.1.2

Description

Defines the index (one-based) of the associated CMC PSU.

Syntax

DellCMCPSUIndexRange

Access

Read-only

DRsPSULocation
Name

DRsPSULocation

Object ID

1.3.6.1.4.1.674.10892.2.4.2.1.3

Description

Defines the location of the CMC PSU.

Syntax

DellString

Access

Read-only

DRsPSUMonitoringCapable
Name

DRsPSUMonitoringCapable

Object ID

1.3.6.1.4.1.674.10892.2.4.2.1.4

Description

Defines the PSU Monitoring capabilities, or the absence of a PSU in
this location.

Syntax

DellCMCPSUCapable

Access

Read-only

DRsPSUVoltsReading
Name

DRsPSUVoltsReading

Object ID

1.3.6.1.4.1.674.10892.2.4.2.1.5

Description

Defines the instantaneousPSU Voltage reading.

Syntax

DellPowerReading

Access

Read-only

Dell Remote Access Controller Out-of-Band Group

715

DRsPSUAmpsReading
Name

DRsPSUAmpsReading

Object ID

1.3.6.1.4.1.674.10892.2.4.2.1.6

Description

Defines the instantaneous PSU Current reading.

Syntax

DellPowerReading

Access

Read-only

DRsPSUWattsReading
Name

DrsPSUWattsReading

Object ID

1.3.6.1.4.1.674.10892.2.4.2.1.7

Description

Defines the instantaneous PSU Wattage reading.

Syntax

DellPowerReading

Access

Read-only

Chassis Alerts
The following MIB tables provide information on the chassis management
controller alerts.

DRsCASubSystem
Name

DrsCASubSystem

Object ID

1.3.6.1.4.1.674.10892.2.20.10.1

Description

Defines the Sub-System Name of the CMC Alert.

Syntax

DellString

Access

Read-only

716

Dell Remote Access Controller Out-of-Band Group

DrsCASSCurrStatus
Name

DrsCASSCurrStatus

Object ID

1.3.6.1.4.1.674.10892.2.20.10.2

Description

Defines the Current Status of the Alerting Sub-System.

Syntax

DellStatus

Access

Read-only

DrsCASSPrevStatus
Name

DrsCASSPrevStatus

Object ID

1.3.6.1.4.1.674.10892.2.20.10.3

Description

Defines the Previous Status of the Alerting Sub-System.

Syntax

DellStatus

Access

Read-only

DrsCASSChangeTime
Name

DrsCASSChangeTime

Object ID

1.3.6.1.4.1.674.10892.2.20.10.4

Description

Defines the timestamp of Most Recent Change of the Alerting SubSystem.

Syntax

TimeTicks

Access

Read-only

DrsCAMessage
Name

DrsCAMessage

Object ID

1.3.6.1.4.1.674.10892.2.20.10.5

Description

Defines the CSSD message of the CMC Alert.

Syntax

DellString

Access

Read-only

Dell Remote Access Controller Out-of-Band Group

717

Legacy Alerting
The following MIB tables provide information on the RAC legacy alerting.

DRsAlertSystem
Name

DRsAlertSystem

Object ID

1.3.6.1.4.1.674.10892.2.5000.10.1

Description

Name of the system generating the alert.

Syntax

Octet String(SIZE (0..255))

Access

Read-only

DRsAlertTableIndexOID
Name

DRsAlertTableIndexOID

Object ID

1.3.6.1.4.1.674.10892.2.5000.10.2

Description

Alert Index Object Identifier.

Syntax

OBJECT IDENTIFIER

Access

Read Only

DRsAlertMessage
Name

DRsAlertMessage

Object ID

1.3.6.1.4.1.674.10892.2.5000.10.3

Description

Message describing the alert.

Syntax

Octet String (SIZE (0..1024))

Access

Read-only

718

Dell Remote Access Controller Out-of-Band Group

DRsAlertCurrentStatus
Name

DRsAlertCurrentStatus

Object ID

1.3.6.1.4.1.674.10892.2.5000.10.4

Description

Current status of object causing the alert.

Syntax

DellStatus

Access

Read-only

DRsAlertPreviousStatus
Name

DRsAlertPreviousStatus

Object ID

1.3.6.1.4.1.674.10892.2.5000.10.5

Description

Previous status of object causing the alert.

Syntax

DellStatus

Access

Read-only

DRsAlertData
Name

DRsAlertData

Object ID

1.3.6.1.4.1.674.10892.2.5000.10.6

Description

Alert data

Syntax

Octet String (SIZE (0..1024))

Access

Read-only

Dell Remote Access Controller Out-of-Band Group

719

720

Dell Remote Access Controller Out-of-Band Group

Traps

27

The Server Administrator generates events that result in Simple Network
Management Protocol (SNMP) traps or operating system event logs. Remote
Access Controller (RAC) and Baseboard Management Controller (BMC) can
also generate SNMP traps in response to hardware events. This section
describes the traps, also known as alerts, generated by the Server
Administrator, RAC, and BMC.
The Server Administrator generates events in response to changes in the
status of sensors and other monitored parameters. When an event with
predefined characteristics occurs on your system, the SNMP subagent sends
information about the event, along with trap variables, to the management
console.
Each status change event generates a unique identifier called the TrapID and
a trap description that describes the event. The TrapID and message uniquely
describe the severity and cause of the event, and provide other relevant
information such as the location of the event and the monitored item’s
previous state.
"Instrumentation Traps" on page 696 lists all Server Administrator
Instrumentation TrapIDs in numerical order and includes each TrapID’s
corresponding description, severity level, and cause. Description text in
brackets (for example, ) describes the event-specific information
provided by Server Administrator.
"RAC Traps" on page 721 lists RAC TrapIDs in numerical order and includes
each TrapID’s corresponding description, severity level, and cause.
"BMC Traps" on page 726 lists BMC TrapIDs and includes each TrapID’s
corresponding description and severity level.

Trap Variables
This section describes the variables that are sent to the management console
to provide additional information about a trap or alert generated by some
event on your system. The trap variables presented here apply to all
Instrumentation and RAC traps. Trap variables are sent in the order listed and

Traps

721

are reserved for use only in traps. When a varbind is created for a trap
variable, a zero is appended to the object ID (OID) to create the OID for the
varbind.

System
Variable Name

alertSystem

Object ID

1.3.6.1.4.1.674.10892.1.5000.10.1

Description

Identifies the system generating the alert.

Syntax

DisplayString (SIZE (0..255))

Table Index OID
Variable Name

alertTableIndexOID

Object ID

1.3.6.1.4.1.674.10892.1.5000.10.2

Description

Specifies the object identifier for the index attribute in the
table that contains the object causing the alert. Uniquely
identifies the object causing the alert and can be used to
correlate different alerts caused by the same object.

Syntax

OBJECT IDENTIFIER

Message
Variable Name

alertMessage

Object ID

1.3.6.1.4.1.674.10892.1.5000.10.3

Description

Describes the alert.

Syntax

DisplayString (SIZE (0..1024))

Current Status
Variable Name

alertCurrentStatus

Object ID

1.3.6.1.4.1.674.10892.1.5000.10.4

Description

Specifies the current status of the object causing the alert.

Syntax

DellStatus

722

Traps

Previous Status
Variable Name

alertPreviousStatus

Object ID

1.3.6.1.4.1.674.10892.1.5000.10.5

Description

Specifies the previous status of the object causing the alert.

Syntax

DellStatus

Data
Variable Name

alertData

Object ID

1.3.6.1.4.1.674.10892.1.5000.10.6

Description

Provides Server Administrator-defined data related to the
alert.

Syntax

Octet String (SIZE (0..1024))

Understanding the Trap Description
Table 27-1 lists in alphabetical order each line item that may appear in the
trap description.
Description Line Item

Explanation

Action performed was:


Specifies the automatic server recovery action
that was performed, for example:
Action performed was: Power cycle

Action requested was:


Specifies the user initiated host control action
that was requested, for example:
Action requested was: Reboot,
shutdown OS first

Traps

723

Description Line Item

Explanation

Additional details:
Specifies possible additional details about the

Additional details:

Memory device: DIMM_1A Serial
number: 11111111
Memory device: DIMM_1B Serial
number: 22222222


Specifies any additional power supply
information pertaining to the event, for
example:
Power supply input AC is off,
Power supply POK (power OK)
signal is not normal, Power
supply is turned off

Battery sensor status:


Specifies the status reported by the battery
sensor, for example:
Battery sensor status:
Predictive failure

Chassis intrusion
state:

Specifies the chassis intrusion state (open or
closed), for example:



Chassis intrusion state: Open

Chassis location:

Specifies the name of the chassis that
generated the message, for example:



Chassis location: Main System
Chassis
Configuration error
type: 

Specifies the type of configuration error that
occurred, for example:

Current sensor value
(in Amps): 

Specifies the current sensor value in amps,
for example:

Configuration error type:
Revision mismatch

Current sensor value: 7.853

724

Traps

Description Line Item

Explanation

Date and time of
Specifies the date and time that an automatic
action:  server recovery action was performed, for
example:

Date and time of action:
Fri May 30 23:55:44 2003.
Description:


Specifies the description of the event that
occurred, for example:
Description: Chipset Err:
Critical Event sensor, front
panel NMI / diagnostic interrupt
was asserted.

Device location:


Specifies the location of the device in the
specified chassis, for example:
Device location: Mem Card A

Discrete current state: Specifies the state of the current sensor, for

example:
Discrete current state: Good
Discrete temperature
state: 

Specifies the state of the temperature sensor,
for example:
Discrete temperature state: Good

Discrete voltage state: Specifies the state of the voltage sensor, for

example:
Discrete voltage state: Good
Fan sensor value:


Specifies the fan speed in revolutions per
minute (RPMs) or On/Off, for example:
Fan sensor value (in RPM): 2600
Fan sensor value: Off

Log type: 

Specifies the type of hardware log, for example:
Log type: Embedded Server
Management (ESM)

Traps

725

Description Line Item

Explanation

Memory device bank
location:

Specifies the name of the memory bank in the
system that generated the message, for
example:



Memory device bank location:
Bank_1
Memory device location: Specifies the location of the memory module
in the chassis, for example:


Memory device location: DIMM_A

Number of devices
required for full
redundancy: 

Specifies the number of power supply or
cooling devices required to achieve full
redundancy, for example:
Number of devices required for
full redundancy: 4

Peak value (in Watts):


Specifies the peak value in Watts, for example:

Possible memory module
event cause: 

Specifies a list of possible causes for the
memory module event, for example:

Peak value (in Watts): 125

Possible memory module event
cause: Single bit warning error
rate exceeded
Single bit error logging disabled

Power Supply type:


Specifies the type of power supply, for example:

Pre-failure state was:


Specifies the status of the previous memory
message, for example:

Power Supply type: VRM

Pre-failure state was: Failed
Previous redundancy
state was: 

Specifies the status of the previous redundancy
message, for example:
Previous redundancy state was:
Lost

Previous state was:


Specifies the previous state of the sensor, for
example:
Previous state was: OK (Normal)

726

Traps

Description Line Item

Explanation

Processor sensor
status:

Specifies the status of the processor sensor, for
example:



Processor sensor status:
Configuration error

Specifies the location of the redundant power

Redundancy unit: Fan Enclosure
Redundancy unit:

SD card device type:


Specifies the type of SD card device, for
example:
SD card device type: Hypervisor

SD card state:

Specifies the state of the SD card, for example:



SD card state: Present, Failed

Sensor location:

Specifies the location of the sensor in the
specified chassis, for example:



Sensor location: CPU1
Temperature sensor
value (in degrees
Celsius):

Specifies the temperature in degrees Celsius,
for example:



Temperature sensor value (in
degrees Celsius): 30

Voltage sensor value
(in Volts):

Specifies the voltage sensor value in volts, for
example:



Voltage sensor value: 1.693

Understanding Trap Severity
Traps often contain information about values recorded by probes or sensors.
Probes and sensors monitor critical components for values such as amperage,
voltage, and temperature. When an event occurs on your system, the Server
Administrator sends information about one of the following event types to
the system management console:
•

Information/Informational—An event that describes the successful
operation of a unit, such as a power supply turning on or a sensor reading
returning to normal.
Traps

727

•

Warning — An event that is not necessarily significant, but may indicate a
possible future problem, such as crossing a warning threshold.

•

Critical/Error — A significant event that indicates actual or imminent loss
of data or loss of function, such as crossing a failure threshold or a
hardware failure.

Instrumentation Traps
This section describes the traps that are generated by the Instrumentation
service of the Server Administrator. All of the traps documented in this
section belong to the MIB enterprise identified by OID
1.3.6.1.4.1.674.10892.1 and are sent with all of the trap variables documented
in the section, "Trap Variables" on page 690. The trap variables are sent in the
order in which they are listed. The messages in the Description fields below
show the format of the message that is sent in the alertMessage varbind. If a
message in a Description field has multiple lines, the message contains
newline (0Ah) characters that are part of the value in the alertMessage
varbind.

728

Traps

Miscellaneous Traps
Table 27-2 lists Miscellaneous traps that inform you that certain alert systems
are up and working.
TrapID Description

Severity

Cause

System Up
1001

Server Administrator
startup complete

Information Server Administrator completed its
initialization.

Thermal Shutdown
1004

Thermal shutdown
protection has been
initiated

Error

This message is generated when a
system is configured for thermal
shutdown due to an error event. If a
temperature sensor reading exceeds
the error threshold for which the
system is configured, the operating
system shuts down and the system
powers off. This event may also be
initiated on certain systems when a
fan enclosure is removed from the
system for an extended period of
time.

Automatic System Recovery
1006

Automatic System
Error
Recovery (ASR) action was
performed
Action performed was:

Date and time of action:


This message is generated when an
automatic system recovery action is
performed due to a hung operating
system. The action performed and
the date and time of the action are
provided.

Traps

729

TrapID Description

Severity

Cause

Host System Reset
1007

User initiated host system Information User requested a host system
control action
control action to reboot, power off,
or power cycle the system or
Action requested was:
another event such as thermal

shutdown protection initiated a
power off, operating
system shutdown.

System Peak Power New Peak
1013

System Peak Power
detected new peak value
Peak value (in Watts):


Information This message is generated when the
system peak power sensor has
detected a new peak value.

System Software Event
1014

System software event has Minor
occured.
Description: 
Date and time of action:


730

Traps

This message is generated when a
system software event occurs. The
description of the event and the
date and time of the event are
provided.

Temperature Probe Traps
Temperature probes help protect critical components by alerting the systems
management console when temperatures become too high inside a chassis.
The temperature probe traps use additional variables: sensor location, chassis
location, previous state, and temperature sensor value reported in degrees
Celsius.
TrapID Description

Severity

Cause

Temperature Probe Normal
1052

Temperature sensor returned to a
normal value

Information A temperature sensor
on the backplane
board, system board,
Sensor location: 
or drive carrier in the
Chassis location: 
specified system
returned to a valid
Previous state was: 
range after crossing a
If sensor type is not discrete:
failure threshold.
Temperature sensor value (in degrees
The sensor location,
Celsius): 
chassis location,
If sensor type is discrete: Discrete
previous state, and
temperature state: 
temperature sensor
value are provided.

Temperature Probe Warning
1053

Temperature sensor detected a
warning value
Sensor location: 
Chassis location: 
Previous state was: 
If sensor type is not discrete:
Temperature sensor value (in degrees
Celsius): 
If sensor type is discrete: Discrete
temperature state: 

Warning

A temperature sensor
on the backplane
board, system board,
or drive carrier in the
specified system
exceeded its warning
threshold. The sensor
location, chassis
location, previous
state, and
temperature sensor
value are provided.

Traps

731

TrapID Description

Severity

Cause

Error

A temperature sensor
on the backplane
board, system board,
or drive carrier in the
specified system
exceeded its failure
threshold. The sensor
location, chassis
location, previous
state, and
temperature sensor
value are provided.

Error

A temperature sensor
on the backplane
board, system board,
or drive carrier in the
specified system
detected an error
from which it cannot
recover. The sensor
location, chassis
location, previous
state, and
temperature sensor
value are provided.

Temperature Probe Failure
1054

Temperature sensor detected a
failure value
Sensor location: 
Chassis location: 
Previous state was: 
If sensor type is not discrete:
Temperature sensor value (in degrees
Celsius): 
If sensor type is discrete: Discrete
temperature state: 

Temperature Probe Non-recoverable
1055

Temperature sensor detected a
non-recoverable value
Sensor location: 
Chassis location: 
Previous state was: 
If sensor type is not discrete:
Temperature sensor value (in degrees
Celsius): 
If sensor type is discrete: Discrete
temperature state: 

732

Traps

Cooling Device Traps
Cooling device traps monitor how well a fan is functioning.
TrapID Description

Severity

Cause

Cooling Device Normal
1102

Fan sensor returned to a normal
value

Information A fan sensor reading on
the specified system
returned to a valid range
Sensor location: 
threshold. The sensor
Chassis location: 
location, chassis location,
previous state, and fan
Previous state was: 
sensor value are
Fan sensor value: 
provided.

Cooling Device Warning
1103

Fan sensor detected a warning value Warning
Sensor location: 
Chassis location: 
Previous state was: 
Fan sensor value: 

A fan sensor reading in
the specified system
exceeded a warning
threshold. The sensor
location, chassis location,
previous state, and fan
sensor value are
provided.

Traps

733

TrapID Description

Severity

Cause

Error

A fan sensor in the
specified system
detected the failure of
one or more fans. The
sensor location, chassis
location, previous state,
and fan sensor value are
provided.

Error

A fan sensor detected an
error from which it
cannot recover. The
sensor location, chassis
location, previous state,
and fan sensor value are
provided.

Cooling Device Failure
1104

Fan sensor detected a failure value
Sensor location: 
Chassis location: 
Previous state was: 
Fan sensor value: 

Cooling Device Non-recoverable
1105

Fan sensor detected a
non-recoverable value
Sensor location:

Chassis location: 
Previous state was: 
Fan sensor value: 

734

Traps

Voltage Probe Traps
Voltage probes monitor the number of volts across critical components.
TrapID Description

Severity

Cause

Voltage Probe Normal
1152

Voltage sensor returned to a
normal value

Information A voltage sensor in the
specified system
returned to a valid range
Sensor location: 
after crossing a failure
Chassis location: 
threshold. The sensor
location, chassis
If sensor type is not discrete:
location, previous state,
Voltage sensor value (in Volts):
and voltage sensor value

are provided.
If sensor type is discrete: Discrete
voltage state: 

Voltage Probe Warning
1153

Voltage sensor detected a warning value Warning
Sensor location: 
Chassis location: 
If sensor type is not discrete:
Voltage sensor value (in Volts):

If sensor type is discrete: Discrete
voltage state: 

A voltage sensor in the
specified system
exceeded its warning
threshold. The sensor
location, chassis
location, previous state,
and voltage sensor value
are provided.

Voltage Probe Failure
1154

Voltage sensor detected a failure value
Sensor location: 
Chassis location: 
Previous state was: 
If sensor type is not discrete:
Voltage sensor value (in Volts):


Error

A voltage sensor in the
specified system
exceeded its failure
threshold. The sensor
location, chassis
location, previous state,
and voltage sensor value
are provided.

If sensor type is discrete: Discrete
voltage state: 

Traps

735

TrapID Description

Severity

Cause

Error

A voltage sensor in the
specified system
detected an error from
which it cannot recover.
The sensor location,
chassis location,
previous state, and
voltage sensor value are
provided.

Voltage Probe Non-recoverable
1155

Voltage sensor detected a
non-recoverable value
Sensor location: 
Chassis location: 
Previous state was: 
If sensor type is not discrete:
Voltage sensor value (in Volts):

If sensor type is discrete: Discrete
voltage state: 

736

Traps

Amperage Probe Traps
Amperage probes measure the amount of current (in amperes) that is
traversing critical components.
TrapID Description

Severity

Cause

Amperage Probe Normal
1202

Current sensor returned to a
normal value

Information A current sensor on the
power supply for the
specified system
or
returned to a valid
Current sensor reading is withing range
range after crossing a
failure threshold. The
Sensor location: 
sensor location, chassis
Chassis location: 
location, previous state,
Previous state was: 
and current sensor
value are provided.
If sensor type is not discrete: Current
sensor value (in Amps): 
If sensor type is discrete: Discrete
current state: 

Amperage Probe Warning
1203

Current sensor detected a
warning value
Sensor location: 
Chassis location: 
Previous state was: 
If sensor type is not discrete: Current
sensor value (in Amps): 
If sensor type is discrete: Discrete
current state: 

Warning

A current sensor on the
power supply for the
specified system
exceeded its warning
threshold. The sensor
location, chassis
location, previous state,
and current sensor
value are provided.

Traps

737

TrapID Description

Severity

Cause

Amperage Probe Failure
1204

Current sensor detected a failure value Error
Sensor location: 
Chassis location: 
Previous state was: 
If sensor type is not discrete: Current
sensor value (in Amps): 
If sensor type is discrete: Discrete
current state: 

A current sensor on the
power supply for the
specified system
exceeded its failure
threshold. The sensor
location, chassis
location, previous state,
and current sensor
value are provided.

Amperage Probe Non-recoverable
1205

Current sensor detected a
non-recoverable value
Sensor location: 
Chassis location: 
Previous state was: 
If sensor type is not discrete: Current
sensor value (in Amps): 
If sensor type is discrete: Discrete
current state: 

738

Traps

Error

A current sensor in the
specified system
detected an error from
which it cannot recover.
The sensor location,
chassis location,
previous state, and
current sensor value are
provided.

Chassis Intrusion Traps
Chassis intrusion traps are a security measure. Chassis intrusion means that
someone is opening the cover to a system’s chassis. Alerts are sent to prevent
unauthorized removal of parts from a chassis.
TrapID Description

Severity

Cause

Chassis Intrusion Normal
1252

Chassis intrusion returned to
normal

Information A chassis intrusion sensor
in the specified system
detected that a cover was
Sensor location: 
was operating but has
Chassis location: 
sensor location, chassis
location, previous state,
Previous state was: 
and chassis intrusion state
Chassis intrusion state: 

Chassis Intrusion Detected
1254

Chassis intrusion detected
Sensor location: 
Chassis location: 
Previous state was: 
Chassis intrusion state: 

Error

A chassis intrusion sensor
in the specified system
detected that the system
cover was opened while
the system was operating.
The sensor location,
chassis location, previous
state, and chassis intrusion
state are provided.

Traps

739

Redundancy Unit Traps
Redundancy means that a system chassis has more than one of certain critical
components. Fans and power supplies, for example, are so important for
preventing damage or disruption of a computer system that a chassis may
have extra fans or power supplies installed. Redundancy allows a second or
nth fan to keep the chassis components at a safe temperature when the
primary fan has failed. Redundancy is normal when the intended number of
critical components are operating. Redundancy is degraded when a
component fails but others are still operating. Redundancy is lost when the
number of components functioning falls below the redundancy threshold.
The number of devices required for full redundancy is provided as part of the
trap message when applicable for the redundancy unit and the platform. For
more details on redundancy computation, please refer to the respective
platform documentation.
TrapID Description

Severity

Cause

Redundancy Normal
1304

740

Redundancy regained

Information A redundancy sensor in the
specified system detected
Redundancy unit: 
device has been reconnected
Chassis location: 
is in effect. The redundancy
unit location, chassis
Previous redundancy state was:
location, and previous

redundancy state are
Number of devices required for
provided.
full redundancy: 

Traps

TrapID Description

Severity

Cause

Warning

A redundancy sensor in the
specified system detected
that one of the components
of the redundancy unit has
failed but the unit is still
redundant. The redundancy
unit location, chassis
location, and previous
redundancy state are
provided.

Redundancy Degraded
1305

Redundancy degraded
Redundancy unit: 
Chassis location: 
Previous redundancy state was:

Number of devices required for
full redundancy: 

Redundancy Lost
1306

Redundancy lost

Warning or
Redundancy unit: 
on the
Chassis location: 
units that
are
Previous redundancy state was:
functional)


Number of devices required for
full redundancy: 

A redundancy sensor in the
specified system detected
that one of the components
in the redundant unit has
been disconnected, has
failed, or is not present. The
redundancy unit location,
chassis location, and
previous redundancy state
are provided.

Traps

741

Power Supply Traps
Power supply traps provide status and warning information for power supplies
present in a particular chassis.
TrapID Description

Severity

Cause

Power Supply Normal
1352

Power supply returned to normal Information
Sensor location: 
Chassis location: 
Previous state was: 

A power supply has been
reconnected or replaced.
The sensor location, chassis
location, previous state, and
additional information
about the power supply
event are provided.

Power Supply type: 

If in configuration error state:
Configuration error type: 
Power Supply Warning
1353

Power supply detected a warning Warning
Sensor location: 
Chassis location: 
Previous state was: 
Power Supply type: 

If in configuration error state:
Configuration error type: 

742

Traps

A power supply sensor has
detected a warning
condition. The sensor
location, chassis location,
previous state, and
additional power supply
status information are
provided.

TrapID Description

Severity

Cause

Error

A power supply has been
disconnected or has failed.
The sensor location, chassis
location, previous state, and
additional information
about the power supply
event are provided.

Power Supply Failure
1354

Power supply detected a failure
Sensor location: 
Chassis location: 
Previous state was: 
Power Supply type: 

If in configuration error state:
Configuration error type: 

Memory Device Traps
Memory device messages provide status and warning information for memory
modules present in a particular system. Memory devices determine health
status by counting the number of ECC memory corrections.
NOTE: A value of failure or non-recoverable does not indicate a system
failure or loss of data, but rather that the specified system exceeded the specified
ECC correction threshold. Although the system continues to function, you should
perform system maintenance as described in Table 27-10.
TrapID Description
1403

Severity

Memory device status:  Warning
Memory device location:

Possible memory module event
cause: 

Cause
A memory device correction
rate exceeded an acceptable
value. The memory device
status and location are
provided.

Traps

743

TrapID Description
1404

Severity

Memory device status:  Error
Memory device location:

Possible memory module event
cause: 

Cause
A memory device correction
rate exceeded an acceptable
value, a memory spare bank
was activated, or a
Uncorrectable Memory
Event occurred. The system
continues to function
normally (except for a
Uncorrectable Memory
Event). Clear the memory
error on Uncorrectable
Memory Event. Replace the
memory module identified in
the message during the
system’s next scheduled
maintenance. The memory
device status and location are
provided.

Fan Enclosure Traps
Some systems are equipped with a protective enclosure for fans. Fan
enclosure traps monitor enclosures for whether foreign objects are present
and for how long a fan enclosure is absent from a chassis.
TrapID Description

Severity

Cause

Information

A fan enclosure has been
inserted into the specified
system. The sensor
location and chassis
location are provided.

Fan Enclosure Insertion
1452

Fan enclosure inserted into
system
Sensor location: 
Chassis location: 

744

Traps

TrapID Description

Severity

Cause

Warning

A fan enclosure has been
removed from the specified
system. The sensor
location and chassis
location are provided.

Fan Enclosure Removal
1453

Fan enclosure removed from
system
Sensor location: 
Chassis location: 

Fan Enclosure Extended Removal
1454

Fan enclosure removed from
Error
system for an extended amount
of time
Sensor location:

Chassis location: 

A fan enclosure has been
removed from the specified
system for a user-definable
length of time. The sensor
location and chassis
location are provided.

Traps

745

AC Power Cord Traps
The AC power cord sensor monitors the presence of AC power for an
AC power cord. AC power cord traps provide status and warning information
for power cords that are part of an AC power switch, if your system supports
AC switching.
TrapID Description

Severity

Cause

AC Power Cord No Power Non-redundant
1501

AC power cord is not being
monitored
Sensor location: 
Chassis location: 

Information The AC power cord status is
not being monitored. This
occurs when a system’s
expected AC power
configuration is set to
nonredundant. The sensor
location and chassis location
information are provided.

AC Power Cord Normal
1502

AC power has been restored
Sensor location: 
Chassis location: 

Information An AC power cord that did
not have AC power has had
the power restored. The
sensor location and chassis
location information are
provided.

AC Power Cord Failure
1504

AC power has been lost
Sensor location: 
Chassis location: 

746

Traps

Error

An AC power cord has lost
its power. The sensor
location and chassis location
information are provided.

Hardware Log Traps
Hardware logs provide hardware status messages to systems management
software. On certain systems, the hardware log is implemented as a circular
queue. When the log becomes full, the oldest status messages are overwritten
when new status messages are logged. On some systems, the log is not
circular. When the log becomes full, subsequent hardware status messages are
lost. Hardware log sensor messages provide status and warning information
about the noncircular logs that may fill up, resulting in lost status messages.
TrapID Description

Severity

Cause

Hardware Log Normal
1552

Log size is no longer near or
at capacity
Log type: 

Information The hardware log on the
specified system is no
longer near or at its
capacity, usually as the
result of clearing the log.
The log type information is
provided.

Hardware Log Warning
1553

Log size is near or at capacity

Warning

The size of a hardware log
on the specified system is
near or at the capacity of
the hardware log. The log
type information is
provided.

Error

The size of a hardware log
on the specified system is at
the capacity of the
hardware log. The log type
information is provided.

Log type: 

Hardware Log Full
1554

Log size is full
Log type: 

Processor Device Status Traps
The BMC on some systems reports the status of processor devices. Processor
device status traps provide status and warning information for processor devices
present in a system with a BMC that reports the status of processor devices.

Traps

747

TrapID Description

Severity

Cause

Processor Device Status Normal
1602

Processor sensor returned to a
normal value
Sensor Location: 
Chassis Location: 

Information A processor sensor in the
specified system
transitioned back to a
normal state. The sensor
location, chassis location,
previous state and processor
sensor status are provided.

Previous state was: 
Processor sensor status: 
Processor Device Status Warning
1603

Processor sensor detected a
warning value

Warning

Sensor Location: 
Chassis Location: 

A processor sensor in the
specified system is in a
throttled state. The sensor
location, chassis location,
previous state and processor
sensor status are provided.

Previous state was: 
Processor sensor status: 
Processor Device Status Failure
1604

Processor sensor detected a failure Error
value
Sensor Location: 
Chassis Location: 
Previous state was: 
Processor sensor status: 

748

Traps

A processor sensor in the
specified system is disabled,
has a configuration error, or
experienced a thermal trip.
The sensor location, chassis
location, previous state and
processor sensor status are
provided.

Pluggable Device Traps
Server Administrator monitors the addition and removal of pluggable devices
such as memory cards. Device traps provide information about the addition
and removal of such devices.
TrapID Description

Severity

Cause

Pluggable Device Addition
1651

Device added to system
Device Location:

Chassis Location: 

Information A device was added to the
specified system. The device
location, chassis location, and
additional event details, if
available, are provided.

Pluggable Device Configuration Error
1653

Device configuration error
detected
Device Location:

Chassis Location: 

Error

A configuration error was
detected for a pluggable device
in the specified system. The
device may have been added to
the system incorrectly. The
device location, chassis location,
and additional event details, if
available, are provided.

Pluggable Device Removal
1652

Device removed from
system
Device Location:

Chassis Location: 

Information A device was removed from the
specified system. The device
location, chassis location, and
additional event details, if
available, are provided

Traps

749

Battery Traps
Battery traps provide status and warning information for batteries present in a
system with a BMC that reports the status of batteries.
TrapID Description

Severity

Cause

Battery Normal
1702

Battery sensor returned to a normal
value
Sensor Location: 
Chassis Location: 
Previous state was: 

Information A battery sensor in the
specified system detected
that a battery transitioned
back to a normal state.
The sensor location,
chassis location, previous
state, and battery sensor
status are provided.

Battery sensor status: 
Battery Warning
1703

Battery sensor detected a warning
value or Battery is low

Warning

Sensor Location: 
Chassis Location: 
Previous state was: 

A battery sensor in the
specified system detected
that a battery is in a
predictive failure state.
The sensor location,
chassis location, previous
state, and battery sensor
status are provided.

Battery sensor status: 
Battery Failure
1704

Battery sensor detected a failure
Critical
value or Battery has failed or is absent
Sensor Location: 
Chassis Location: 
Previous state was: 
Battery sensor status: 

750

Traps

A battery sensor in the
specified system detected
that a battery has failed or
is absent. The sensor
location, chassis location,
previous state, and battery
sensor status are provided.

SD Card Device Traps
On systems where the BMC reports the status of SD card devices, the SD
card device traps provide status and error information.
TrapID Description

Severity

Cause

Critical

An SD card device sensor
in the specified system
detected an error. The
sensor location, chassis
location, previous state
and SD card device type
are provided. The SD card
state is provided if a SD
card is present in the SD
card device.

SD Card Device Failure
1754

SD card device detected a failure
Sensor Location: 
Chassis Location: 
Previous state was: 
SD card device type: 
SD card state: 

Traps

751

RAC Traps
This section describes the traps that are generated by the SNMP agent of the
Remote Access Controller (RAC). All of the enterprise-specific traps documented
in this section belong to the MIB enterprise identified by OID
1.3.6.1.4.1.674.10892.2 and are sent with all of the trap variables documented in
the section "Traps" on page 689. The trap variables are sent in the order in which
they are listed.
TrapID Name

Description

Severity

0

CodeStart SNMP agent is
initializing itself

1

Authentic Request received Critical
ation
with an invalid
Failure
community name

Category Cause

Information Status

TrapID Name

Description

1001

The RAC
Information Status
generated a
test trap
event in
response to a
user request

752

alertDrscTest
TrapEvent

Traps

Severity

Error

Supported
by RAC
Platform

RAC power All
on or reset.
SNMP
All
request
with an
invalid
community
name.

Category Cause

Supporte
d by RAC
Platform

A test SNMP All
trap
generated by
a RAC.

TrapID Name

Description

Severity

Category Cause

Supporte
d by RAC
Platform

1002

alertDrscAuth RAC
Minor
Error
Authenticati
on failures
during a
time period
have
exceeded a
threshold

1003

alertDrscLost
ESM

1004

alertDrscFound The RAC is Information Error
ESM
communicat
ing normally
with the
baseboard
management
controller
(ESM)

RAC
DRAC
recovered
III
communicati
on with ESM.

1005

alertDrscPower The RAC
Critical
Off
has detected
a system
power state
change to
powered-off

RAC
DRAC
III
detected a
system power
state change
to power-off.

Critical
The RAC
cannot
communicate
with the
baseboard
management
controller
(ESM)

Error

RAC login
All
failure caused
by
authenticatio
n failure,
number of
concurrent
logins exceed
limit, or
permission
denied.

Error

RAC lost
Dell
communicati Remote
on with ESM. Access
Controlle
r
(DRAC)
III

Error

Traps

753

TrapID Name

Description

Severity

Category Cause

Supporte
d by RAC
Platform

1006

alertDrscPower The RAC
Information Error
On
has detected
a system
power state
change to
powered-on

RAC
DRAC
III
detected a
system power
state change
to power-on.

1007

alertDrsc
Watchdog
Expired

The RAC
Critical
has detected
that the
system
watchdog
has expired
indicating a
system hang

Event

RAC has
DRAC
detected the III
system
watchdog
expired
(normally
indicating a
system hang).

1008

alertDrscBatt
Low

The RAC
Minor
Battery
charge is
below 25%
indicating
that the
battery may
only be able
to power the
DRSC for 810 minutes

Error

RAC
detected its
battery
charge is
below 25%
full.

1009

Information Status
alertDrscTemp The RAC
Temperature
Normal
probe has
returned to a
normal value

1010

alertDrscTemp The RAC
Temperature
Warning
probe has
detected a
Warning
value

754

Traps

Minor

Status

DRAC
III

RAC
DRAC
temperature III
probe reading
returned to
normal.
RAC
DRAC
temperature III
probe reading
exceeded
warning
threshold.

TrapID Name

Description

Severity

Category Cause

1011

alertDrscTemp The RAC
Critical
Temperature
probe has
detected a
failure (or
critical)
value

Critical

Error

RAC
DRAC
temperature III
probe reading
exceeded
critical
threshold.

1012

alertDrscVolt
Normal

The RAC
Information Error
voltage has
returned to a
normal value

RAC voltage DRAC
probe reading III
returns to
normal.

1013

alertDrscVolt
Warning

The RAC
voltage
probe has
detected a
warning
value

Minor

Error

RAC voltage DRAC
probe reading III
exceeded
warning
threshold.

1014

alertDrscVolt
Critical

The RAC
voltage
probe has
detected a
failure (or
critical)
value

Critical

Error

RAC voltage DRAC
probe reading III
exceeded
critical
threshold.

1015

alertDrscSEL
Warning

The RAC
Major
has detected
a new event
in the
System
Event Log
with
Severity:
Warning

Error

RAC
All
detected a
new system
event log with
warning
severity
(detailed log
info is in
drsAlert
Message
varbind).

Traps

Supporte
d by RAC
Platform

755

TrapID Name

Description

Severity

1016

alertDrscSEL
Critical

The RAC
Critical
has detected
a new event
in the
System
Event Log
with
Severity:
Critical

1017

Category Cause

Supporte
d by RAC
Platform

Error

RAC
All
detected a
new system
event log with
critical
severity
(detailed log
info is in
drsAlert
Message
varbind).

alertDrscSEL The RAC
Major
80
system event
percentFull
log is 80%
full

Status

RAC
All
detected
system event
log is 80%
full.

1018

alertDrscSEL The RAC
Major
90
system event
percentFull
log is 90%
full

Status

RAC
All
detected
system event
log is 90%
full.

1019

alertDrscSEL The RAC
Major
100
system event
percentFull
log is 100%
full

Status

RAC
All
detected
system event
log is 100%
full.

756

Traps

TrapID Name

Description

1020

The RAC
Information Error
has detected
a new event
in the
System
Event Log
with
Severity:
Normal

alertDrscSEL
Normal

Severity

Category Cause

Supporte
d by RAC
Platform

RAC
All
detected a
new system
event log with
normal
severity
(detailed log
info is in
drsAlert
Message
varbind).

BMC Traps
The BMC monitors the system for critical events by communicating with
various sensors on the system board and by sending alerts and log events
when certain parameters exceed their preset thresholds. All of the traps
documented in this section belong to the MIB enterprise identified by OID
1.3.6.1.4.1.3183.1.1.1.
TrapID

Description

Severity

262402

Generic Critical Fan Failure

Critical

262530

Generic Critical Fan Failure Cleared

Information

131330

Under-Voltage Problem (Lower Critical - going low)

Critical

131458

Under-Voltage Problem Cleared

Information

131841

Generic Critical Voltage Problem

Critical

131840

Generic Critical Voltage Problem Cleared

Information

65792

Under-Temperature Warning (Lower non-critical,
going low)

Warning

65920

Under-Temperature Warning Cleared

Information

65794

Under-Temperature Problem (Lower Critical - going low)

Critical

65922

Under-Temperature Problem Cleared

Information

Traps

757

TrapID

Description

Severity

65799

Over-Temperature warning (Upper non-critical, going high) Minor

65927

Over-Temperature warning Cleared

Information

65801

Over-Temperature Problem (Upper Critical - going high)

Critical

65929

Over-Temperature Problem Cleared

Information

131328

Under-Voltage Warning (Lower Non Critical - going low)

Warning

131456

Under-Voltage Warning Cleared

Information

131330

Under-Voltage Problem (Lower Critical - going low)

Critical

131458

Under-Voltage Problem Cleared

Information

131335

Over-Voltage Warning (Upper Non Critical - going high)

Warning

131463

Over-Voltage Warning Cleared

Information

131337

Over-Voltage Problem (Upper Critical - going high)

Critical

131465

Over-Voltage Problem Cleared

Information

131841

Generic Critical Voltage Problem

Critical

131840

Generic Critical Voltage Problem Cleared

Information

356096

Chassis Intrusion - Physical Security Violation

Critical

356224

Chassis Intrusion (Physical Security Violation)
Event Cleared

Information

262400

Generic Predictive Fan Failure (predictive failure asserted) Minor

262528

Generic Predictive Fan Failure Cleared

Information

262402

Generic Critical Fan Failure

Critical

262530

Generic Critical Fan Failure Cleared

Information

264962

Fan redundancy has been degraded

Warning

264961

Fan Redundancy Lost

Critical

264960

Fan redundancy has returned to Normal

Information

2715392 Battery Low (Predictive Failure)

Warning

2715520 Battery Low (Predictive Failure) Cleared

Information

2715393 Battery Failure

Critical

2715521 Battery Failure Cleared

Information

758

Traps

TrapID

Description

Severity

487169

CPU Thermal Trip (Over Temperature Shutdown)

Critical

487297

CPU Thermal Trip (Over Temperature Shutdown) Cleared Information

487168

CPU Internal Error

Critical

487296

CPU Internal Error Cleared

Information

487173

CPU Configuration Error

Critical

487301

CPU Configuration Error Cleared

Information

487175

CPU Presence (Processor Presence detected)

Information

487303

CPU Not Present (Processor Not Present)

Critical

487170

CPU BIST (Built In Self Test) Failure

Critical

487298

CPU BIST (Built In Self Test) Failure Cleared

Information

487176

CPU Disabled (Processor Disabled)

Critical

487304

CPU Enabled (Processor Enabled)

Information

487178

CPU Throttle (Processor Speed Reduced)

Warning

487306

CPU Throttle Cleared (Normal Processor Speed)

Information

527106

Power Supply Redundancy Degraded

Warning

527105

Power Supply Redundancy Lost

Critical

527104

Power Supply Redundancy has returned to Normal

Information

552704

Power Supply Inserted

Information

552832

Power Supply Removed

Warning

552705

Power Supply Failure

Critical

552833

Power Supply Failure Cleared

Information

552706

Power Supply Warning

Warning

552834

Power Supply Warning Cleared

Information

552707

Power Supply AC Lost

Critical

552835

Power Supply AC Restored

Information

789249

Memory Redundancy has been Lost

Critical

789248

Memory redundancy has returned to Normal

Information

1076994 System Event Log (SEL) Cleared

Information
Traps

759

TrapID

Description

Severity

1076996 System Event Log (SEL) Full (Logging Disabled)

Critical

2322176 ASR (Automatic System Recovery) Timer Expired

Critical

2322177 ASR (Automatic System Recovery) Reset Occurred

Critical

2322178 ASR (Automatic System Recovery) Power Down Occurred Critical
2322179 ASR (Automatic System Recovery) Power Cycle Occurred

760

Traps

Critical

Traps

761

762

Traps

Storage Management Alert
Reference

28

Storage Management’s alert or event management features let you monitor
the health of storage resources such as controllers, connectors, array disks,
and virtual disks.

Alert Monitoring and Logging
The Storage Management Service performs alert monitoring and logging.
By default, the Storage Management Service starts when the managed system
starts up. If you stop the Disk Management Service, then alert monitoring
and logging stops. Alert monitoring does the following:
•

Updates the status of the storage object that generated the alert.

•

Propagates the storage object’s status to all the related higher objects in
the storage hierarchy. For example, the status of a lower-level object are
propagated up to the status displayed on the Health tab for the top-level
storage object.

•

Logs an alert into the Alert log and Microsoft Windows application log.

•

Sends an Simple Network Management Protocol (SNMP) trap if the
operating system’s SNMP service is installed and enabled.
NOTE: Storage Management does not log alerts regarding the data I/O path. These
alerts are logged by the respective RAID drivers in the system alert log.

Storage Management Alert Reference

763

Viewing Alerts
Storage Management generates alerts that are added to the Windows
application alert log and to the Server Administrator Alert log. To view these
alerts in Server Administrator:
1 Select the System object in the tree view.
2 Select the Logs tab.
3 Select the Alert subtab.
You can also view these alerts in the Windows Event Viewer. Every alert
consists of the following:
•

Severity — Shows the severity of alert.

•

Date and Time — Date and time when Storage Management logged the
alert.

•

Description — A brief description of the alert. To expand or collapse the
alert description, click the Description column heading.

Alert Severity Levels
Each alert message in the Storage Management alert log has a severity level
which indicates the nature of the alert and is displayed in the Severity field of
the alert message. The severity level indicates the nature of the alert.

764

Storage Management Alert Reference

The alert severity levels are as follows:
Table 28-1.

Storage Management Alert Severity

Alert Severity

Component Status

OK/Normal/Informational No action is required. The alert is provided for
informational purposes and does not indicate an error
condition. For example, the alert may indicate the
normal start or stop of an operation.
Warning/Non-critical

A component requires attention. This alert indicates a
potential problem, but does not necessarily mean that
the system has currently lost data or is nonfunctional.
For example, a Warning/Non-critical alert may indicate
that a component (such as a temperature probe in an
enclosure) has crossed a warning threshold.

Critical/Failure/Error

A component has either failed or failure is imminent.
This alert indicates a serious problem such as data loss or
a loss of function. For example, a Critical/Failure/Error
alert may indicate that an array disk has failed.

SNMP Support for Storage Management Alerts
By default, Storage Management installs SNMP trap forwarding support.
For this support to function, you should have SNMP installed on the
managed system prior to installing Storage Management.
NOTE: For more information on installation requirements and SNMP, see the
Server Administrator documentation.

SNMP Trap Forwarding
The Storage Management alerts are displayed in the Server Administrator
alert log and are forwarded to the Windows application alert log. If you have
SNMP installed on the managed system (and the SNMP service is running),
the Storage Management alerts in the Windows application alert log are
forwarded as SNMP traps. In order for these traps to be viewable, however,
a target system or application must be configured to receive these traps.
SNMP traps that are generated by Storage Management can be viewed in any
standard SNMP-compatible enterprise management console.

Storage Management Alert Reference

765

The Windows SNMP service must be configured to forward the SNMP traps to
the target system or application. When forwarding to an application, the
application should also be configured to receive the SNMP traps. The IT
Assistant application is already configured to receive the SNMP traps
generated by Storage Management.
See your Windows operating system documentation for information on
configuring the operating system to forward SNMP traps. This information
may be located under such topics as “setting up SNMP” or “SNMP traps.”
When configuring SNMP for Windows, be sure that the SNMP traps are
forwarded to the correct server. For information on configuring an application
to receive SNMP traps, see the documentation for that application.

SNMP Trap Definitions
The Storage Management management information base (MIB) defines the
SNMP traps that Storage Management generates. These traps correspond to
the alerts documented in the "Alert Descriptions and Corrective Actions" on
page 767 section. The MIB is located in ..\sm\mibs\dcstorag.mib, a
subdirectory of the Storage Management installation directory.
NOTE: Storage Management supports trap forwarding on both 32-bit and 64-bit
operating systems.

SNMP Trap Variables
The Storage Management SNMP traps use a set of variables that are included
with every trap. These variables are the following:

766

•

messageIDEvent

•

descriptionEvent

•

locationEvent

•

objectNameEvent

•

objectOIDEvent

•

objectNexusEvent

•

currentStatusEvent

•

previousStatusEvent

Storage Management Alert Reference

Viewing SNMP Traps
SNMP traps that are generated by Storage Management can be viewed in any
standard SNMP-compatible enterprise management console. These traps are
defined in the Storage Management MIB. These traps correspond to the
alerts documented in the “Alert Descriptions and Corrective Actions” section.
For more information on the MIB and its structure, as well as a change history
of the SNMP traps, see the "Introduction" on page 17 section. For more
information on configuring SNMP, see "SNMP Support for Storage
Management Alerts" on page 765.

Alert Descriptions and Corrective Actions
The alerts generated by the redundant array of independent disks (RAID) or
Small Computer System Interface (SCSI) controllers and supported by
Storage Management are displayed in the Server Administrator Alert subtab
or through Windows Event Viewer. These alerts can also be forwarded as
SNMP traps to other applications.
SNMP traps that are generated for the alerts are included in the Storage
Management MIB. The SNMP traps for these alerts use all of the SNMP trap
variables. For the list of storage management alerts and storage management
messages, see the Dell OpenManage Server Administrator Messages Reference
Guide available on the Dell Support website at support.dell.com/manuals.

Storage Management Alert Reference

767

768

Storage Management Alert Reference

29

iDRAC7 MIB

The Integrated Dell Remote Access Controller (iDRAC) MIB (filename
iDRAC-MIB.txt) is the MIB supported by the Integrated Dell Remote
Access Controller 7 (iDRAC7). This MIB provides management data that
allows you to monitor devices and software on a system via an out-of-band
connection to the iDRAC7 of a system.

Supported Systems
The iDRAC7 MIB is supported on the following systems:

Blade Servers
•

PowerEdge M420

•

PowerEdge M520

•

PowerEdge M620

•

PowerEdge M820

Rack and Tower Servers
•

PowerEdge R320

•

PowerEdge R420

•

PowerEdge R520

•

PowerEdge R620

•

PowerEdge R720

•

PowerEdge R720XD

•

PowerEdge R820

•

PowerEdge T320

•

PowerEdge T420

•

PowerEdge T620

iDRAC MIB

iDRAC7 Supported SNMP Versions
The following table identifies the SNMP version(s) that are supported by
iDRAC7 for the given SNMP operations.
SNMP Operations Supported SNMP version
GET, GETNEXT,
GETBULK

SNMP v1 and v2c

TRAP

SNMP v1

iDRAC7 Out-of-Band Group
The objects of the Integrated Dell Remote Access Controller (iDRAC) MIB
(iDRAC-MIB.txt) are organized into subgroups of the iDRAC7 Out-of-Band
Group. The subgroups are:
•

RAC Information Group

•

Chassis Information Group

•

System Information Group

•

Status Group

The following sections document the subgroups and the objects within each
subgroup.

RAC Information Group
The RAC Information Group objects provide information about the iDRAC.
RAC Name
Name

racName

Object ID

1.3.6.1.4.1.674.10892.5.1.1.1.0

Description

This attribute defines the product name of a remote access card.

Syntax

StringType

Access

Read-only

770

iDRAC7 MIB

RAC Short Name
Name

racShortName

Object ID

1.3.6.1.4.1.674.10892.5.1.1.2.0

Description

This attribute defines the short product name of a remote access
card.

Syntax

StringType

Access

Read-only

RAC Description
Name

racDescription

Object ID

1.3.6.1.4.1.674.10892.5.1.1.3.0

Description

This attribute defines the product description of a remote access
card.

Syntax

StringType

Access

Read-only

RAC Manufacturer
Name

racManufacturer

Object ID

1.3.6.1.4.1.674.10892.5.1.1.4.0

Description

This attribute defines the product manufacturer of a remote access
card.

Syntax

StringType

Access

Read-only

RAC Version
Name

racVersion

Object ID

1.3.6.1.4.1.674.10892.5.1.1.5.0

Description

This attribute defines the product version of a remote access card.

Syntax

StringType

Access

Read-only
iDRAC7 MIB

771

RAC URL
Name

racURL

Object ID

1.3.6.1.4.1.674.10892.5.1.1.6.0

Description

This attribute defines the out-of-band UI URL of a remote access
card.

Syntax

StringType

Access

Read-only

RAC Type
Name

racType

Object ID

1.3.6.1.4.1.674.10892.5.1.1.7.0

Description

This attribute defines the type of a remote access card.

Syntax

RacTypeEnum

Access

Read-only

RAC Firmware Version
Name

racFirmwareVersion

Object ID

1.3.6.1.4.1.674.10892.5.1.1.8.0

Description

This attribute defines the firmware version of a remote access card.

Syntax

StringType

Access

Read-only

Chassis Information Group
The Chassis Information Group objects provide information about the
modular chassis in which a blade system resides.
NOTE: This Chassis information is only available for modular/blade systems. For
Rack and Tower systems, the information is empty. Currently there is just one object
under the Chassis Information Group.

772

iDRAC7 MIB

Chassis Service Tag
Name

chassisServiceTag

Object ID

1.3.6.1.4.1.674.10892.5.1.2.1.0

Description

This attribute defines the service tag of the enclosing chassis.

Syntax

StringType

Access

Read-only

System Information Group
The System Information Group objects provide information about the
system in which the iDRAC resides.
System Fully Qualified Domain Name
Name

systemFQDN

Object ID

1.3.6.1.4.1.674.10892.5.1.3.1.0

Description

This attribute defines the fully qualified domain name of the
system.

Syntax

StringType

Access

Read-only

System Service Tag
Name

systemServiceTag

Object ID

1.3.6.1.4.1.674.10892.5.1.3.2.0

Description

This attribute defines the service tag of the system.

Syntax

StringType

Access

Read-only

System Express Service Code
Name

systemExpressServiceCode

Object ID

1.3.6.1.4.1.674.10892.5.1.3.3.0

Description

This attribute defines the express service code of the system.
iDRAC7 MIB

773

Name

systemExpressServiceCode

Syntax

StringType

Access

Read-only

System Asset Tag
Name

systemAssetTag

Object ID

1.3.6.1.4.1.674.10892.5.1.3.4.0

Description

This attribute defines the asset tag of the system.

Syntax

StringType

Access

Read-only

System Blade Slot Number
Name

systemBladeSlotNumber

Object ID

1.3.6.1.4.1.674.10892.5.1.3.5.0

Description

This attribute defines the slot number of the blade in the chassis.

Syntax

StringType

Access

Read-only

System Operating System Name
Name

systemOSName

Object ID

1.3.6.1.4.1.674.10892.5.1.3.6.0

Description

This attribute defines the name of the operating system that the
host is running.

Syntax

StringType

Access

Read-only

System Form Factor
Name

systemFormFactor

Object ID

1.3.6.1.4.1.674.10892.5.1.3.7.0

774

iDRAC7 MIB

Name

systemFormFactor

Description

This attribute defines the form factor of the system.

Syntax

SystemFormFactorEnum

Access

Read-only

System Data Center Name
Name

systemDataCenterName

Object ID

1.3.6.1.4.1.674.10892.5.1.3.8.0

Description

This attribute defines the Data Center locator of the system.

Syntax

StringType

Access

Read-only

System Aisle Name
Name

systemAisleName

Object ID

1.3.6.1.4.1.674.10892.5.1.3.9.0

Description

This attribute defines the Aisle locator of the system.

Syntax

StringType

Access

Read-only

System Rack Name
Name

systemRackName

Object ID

1.3.6.1.4.1.674.10892.5.1.3.10.0

Description

This attribute defines the Rack locator of the system.

Syntax

StringType

Access

Read-only

System Rack Slot
Name

systemRackSlot

Object ID

1.3.6.1.4.1.674.10892.5.1.3.11.0

iDRAC7 MIB

775

Name

systemRackSlot

Description

This attribute defines the Rack Slot locator of the system.

Syntax

StringType

Access

Read-only

System Model Name
Name

systemModelName

Object ID

1.3.6.1.4.1.674.10892.5.1.3.12.0

Description

This attribute defines the model name of the system.

Syntax

StringType

Access

Read-only

Status Group
The Status Group objects provide status information about the system and
storage.
Global System Status
Name

globalSystemStatus

Object ID

1.3.6.1.4.1.674.10892.5.2.1.0

Description

This attribute defines the overall rollup status of all components in
the system being monitored by the remote access card.

Syntax

ObjectStatusEnum

Access

Read-only

System LCD Status
Name

systemLCDStatus

Object ID

1.3.6.1.4.1.674.10892.5.2.2.0

Description

This attribute defines the system status as it is reflected by the
LCD front panel. Not all system components may be included.

Syntax

ObjectStatusEnum

776

iDRAC7 MIB

Name

systemLCDStatus

Access

Read-only

Global Storage Status
Name

globalStorageStatus

Object ID

1.3.6.1.4.1.674.10892.5.2.3.0

Description

This attribute defines the overall storage status being monitored by
the remote access card.

Syntax

ObjectStatusEnum

Access

Read-only

iDRAC7 Traps
The iDRAC7 generates events that result in Simple Network Management
Protocol (SNMP) traps and/or entries in the iDRAC7 Lifecycle Log. This
section describes the traps, also known as alerts, generated by the iDRAC7.
The iDRAC7 generates events in response to changes in the status of sensors
and other monitored parameters. When an event with predefined
characteristics occurs on your system, the SNMP subagent sends information
about the event, along with trap variables, to the management console.
Each event generates an identifier called the trap ID and a list of trap
variables that provide additional details about the event. The trap variables
are listed in the following "Trap Variables" on page 778.
The traps of the iDRAC7 MIB are organized into five subgroups of traps.
Each subgroup corresponds to one of the five categories of events that
iDRAC7 supports (the System Health, Storage Health, Updates, Audit, and
Configuration categories). Here is a list of the trap subgroups are:
•

System Trap Group

•

Storage Trap Group

•

Updates Trap Group

•

Audit Trap Group

•

Configuration Trap Group

iDRAC7 MIB

777

The trap subgroups, and all the traps within each trap subgroup, are described
and listed in sections following the "Trap Variables" section.
NOTE: The traps listed in this document can be correlated to specific events that
are documented in the Dell Event Message Reference guide. There is 1-to-many
relationship between SNMP traps and events in iDRAC7. To correlate a trap to a
specific event or set of events, you can match the Trap ID value of a trap in this
document to the Trap/Event ID value of events in the Dell Event Message Reference
guide.

Trap Variables
This section lists the six variables that are sent with iDRAC7 traps to provide
additional information about a trap or alert generated by some event on the
system. The trap variables presented here apply to all iDRAC7 traps. The trap
variables are sent in the order listed and are reserved for use only in traps.
Alert Message ID
Variable Name

alertMessageID

Object ID

1.3.6.1.4.1.674.10892.5.3.1.1.0

Description

Message ID of the event.

Syntax

DisplayString (SIZE (0..8))

Alert Message
Variable Name

alertMessage

Object ID

1.3.6.1.4.1.674.10892.5.3.1.2.0

Description

Message describing the alert.

Syntax

StringType

Alert Current Status
Variable Name

alertCurrentStatus

Object ID

1.3.6.1.4.1.674.10892.5.3.1.3.0

Description

Current status of object causing the alert, if applicable.

Syntax

ObjectStatusEnum

778

iDRAC7 MIB

Alert System Service Tag
Variable Name

alertSystemServiceTag

Object ID

1.3.6.1.4.1.674.10892.5.3.1.4.0

Description

Service tag of the system.

Syntax

DisplayString (SIZE (0..16))

Alert System FQDN
Variable Name

alertSystemFQDN

Object ID

1.3.6.1.4.1.674.10892.5.3.1.5.0

Description

Fully qualified domain name of the system.

Syntax

StringType

Alert FQDD
Variable Name

alertFQDD

Object ID

1.3.6.1.4.1.674.10892.5.3.1.5.0

Description

Fully qualified device descriptor of the device.

Syntax

DisplayString (SIZE (0..512))

System Trap Group
The System Trap Group contains traps that fall under the “System Health”
event category of the iDRAC7. System Health traps are traps those are
generally generated in response to events related to the hardware of the
system in which an iDRAC7 resides.Amperage Probe Traps

iDRAC7 MIB

779

Table 29-1. Amperage Probe Traps
TrapID Description
Category

SubCategory

Severity

Amperage

Informational

Amperage

Minor

Amperage

Critical

SubCategory

Severity

System
Health

Auto Sys
Reset

Critical

Category

SubCategory

Severity

System
Health

Battery Event Informational

System
Health

Battery Event Minor

System
Health

Battery Event Critical

Amperage Probe Normal
2179

Current sensor reading is System
within range.
Health

Amperage Probe Warning
2178

Current sensor has
System
detected a warning value. Health

Amperage Probe Failure
2177

Current sensor has
detected a failure value.

System
Health

Table 29-2. Automatic System Recovery Trap
TrapID Description
Category

Automatic System Recovery
2233

Automatic system
recovery (ASR) was
performed.

Table 29-3. Battery Traps
TrapID Description
Battery Normal
2227

Battery state has
returned to normal; or
battery presence had
been detected.

Battery Warning
2226

Battery is low.

Battery Failure
2225

780

Battery has failed or
battery is absent.

iDRAC7 MIB

Table 29-4. Processor Device Status Traps
TrapID Description
Category

SubCategory

Severity

System
Health

Processor

Informational

System
Health

Processor

Minor

System
Health

Processor

Critical

SubCategory

Severity

Proc Absent

Critical

Processor DeviceStatus Normal
2243

Processor device status
has returned to normal.

ProcessorDeviceStatusWarning
2242

Processor device status
has detected a warning.

ProcessorDeviceStatusFailure
2241

Processor device status
has detected a failure.

Table 29-5. Processor Device Absent Trap
TrapID Description
Category
Processor Device Absent
2457

Processor device is
absent.

System
Health

iDRAC7 MIB

781

Table 29-6. Fan Traps
TrapID Description

Category

SubCategory

Severity

System
Health

Fan Event

Informational

System
Health

Fan Event

Minor

System
Health

Fan Event

Critical

SubCategory

Severity

System
Health

Hardware
Config

Informational

System
Health

Hardware
Config

Minor

System
Health

Hardware
Config

Critical

SubCategory

Severity

System
Health

Memory

Informational

Memory device status is System
noncritical.
Health

Memory

Minor

Fan Information
2155

Fan information.

Fan Warning
2154

Fan warning.

Fan Failure
2153

Fan failure.

Table 29-7. Hardware Configuration Traps
TrapID Description
Category
Hardware Configuration Information
2331

Hardware configuration
information.

Hardware Configuration Warning
2330

Hardware configuration
warning.

Hardware Configuration Failure
2329

Hardware configuration
failure or critical event.

Table 29-8. Memory Device Traps
TrapID Description
Category
Memory Device Information
2267

Memory device
informational event.

Memory Device Warning
2266

Memory Device Failure

782

iDRAC7 MIB

TrapID Description
2265

Category

Memory device status is System
critical.
Health

SubCategory

Severity

Memory

Critical

iDRAC7 MIB

783

Table 29-9. NIC Traps
TrapID Description

Category

SubCategory

Severity

System
Health

NIC Config

Informational

System
Health

NIC Config

Minor

System
Health

NIC Config

Critical

Table 29-10. Operation System ("OS") Event Traps
TrapID Description
Category
SubCategory

Severity

Network Information
2091

Network information.

Network Warning
2090

Network warning.

Network Failure
2089

Network failure or
critical event.

OS Information
2411

An OS graceful stop
occurred; or an OS
graceful shut-down
occurred.

System
Health

OS Event

Informational

System
Health

OS Event

Critical

Category

SubCategory

Severity

System
Health

PCI Device

Informational

OS Failure
2409

A critical stop occurred
during OS load; or a
runtime critical stop
occurred.

Table 29-11. PCI Device Traps
TrapID Description
PCI Device Information
2419

An informational event
was detected for a PCI
device.

PCI Device Warning

784

iDRAC7 MIB

TrapID Description

Category

SubCategory

Severity

2418

System
Health

PCI Device

Minor

An error was detected for System
a PCI device.
Health

PCI Device

Critical

A warning event was
detected for a PCI
device.

PCI Device Failure
2417

iDRAC7 MIB

785

Table 29-12. Physical Disk Traps
TrapID Description
Category

SubCategory

Severity

Physical Disk Information
2299

Physical disk
information.

System
Health

Physical Disk Informational

System
Health

Physical Disk Minor

System
Health

Physical Disk Critical

Category

SubCategory

Severity

BIOS POST

Critical

SubCategory

Severity

Physical Disk Warning
2298

Physical disk warning.

Physical Disk Failure
2297

Physical disk failure.

Table 29-13. BIOS POST Trap
TrapID Description
Bios Post Failure
2425

System BIOS detected a System
failure.
Health

Table 29-14. Power Supply Traps
TrapID Description
Category
Power Supply Normal
2187

Power supply has
returned to normal.

System
Health

Power Supply Informational

System
Health

Power Supply Minor

System
Health

Power Supply Critical

Power Supply Warning
2186

Power supply has
detected a warning.

Power Supply Failure
2185

786

Power supply has
detected a failure.

iDRAC7 MIB

Table 29-15. Power Supply Absent Trap
TrapID Description
Category

SubCategory

Severity

PSU Absent

Critical

SubCategory

Severity

System
Health

Power Usage

Informational

System
Health

Power Usage

Minor

The system halted
System
because system power
Health
exceeds capacity; or the
system performance
degraded because power
draw exceeds the power
threshold.

Power Usage

Critical

SubCategory

Severity

System
Health

Redundancy

Informational

Redundancy is degraded. System
Health

Redundancy

Minor

Redundancy

Critical

Power Supply Absent
2465

Power supply is absent.

System
Health

Table 29-16. Power Usage Traps
TrapID Description
Category
Power Usage Information
2275

System performance
restored.

Power Usage Warning
2274

System performance
degraded.

Power Usage Failure
2273

Table 29-17. Redundancy Traps
TrapID Description
Category
Redundancy Information
2475

Redundancy
information.

Redundancy Degraded
2474

Redundancy Lost
2473

Redundancy is lost.

System
Health

iDRAC7 MIB

787

Table 29-18. Integrated Dual SD Module Traps
TrapID Description
Category
SubCategory

Severity

Integrated Dual SD ModuleInformation
2211

Integrated Dual SD
Module information.

System
Health

IDSDM
Media

Informational

System
Health

IDSDM
Media

Minor

System
Health

IDSDM
Media

Critical

Integrated Dual SD ModuleWarning
2210

Integrated Dual SD
Module warning.

Integrated Dual SD ModuleFailure
2297

Integrated Dual SD
Module failure.

Table 29-19. Integrated Dual SD Module Absent Trap
TrapID Description
Category
SubCategory

Severity

Integrated Dual SD ModuleAbsent
2481

Integrated Dual SD
Module is absent.

System
Health

IDSDM
Absent

Table 29-20. Integrated Dual SD Module Redundancy Traps
TrapID Description
Category
SubCategory

Critical

Severity

Integrated Dual SD Module Redundancy Information
2491

Integrated Dual SD
Module redundancy
information.

System
Health

IDSDM
Redundancy

Informational

Integrated Dual SD Module Redundancy Degraded
2490

Integrated Dual SD
Module redundancy is
degraded.

System
Health

IDSDM
Redundancy

Minor

IDSDM
Redundancy

Critical

Integrated Dual SD Module Redundancy Lost
2489

788

Integrated Dual SD
Module redundancy is
lost.

iDRAC7 MIB

System
Health

Table 29-21. Security Event Traps
TrapID Description
Category

SubCategory

Severity

System
Health

Security
Event

Informational

Security failure or critical System
event.
Health

Security
Event

Critical

SubCategory

Severity

System
Health

Sys Event
Log

Informational

System
Health

Sys Event
Log

Minor

System Event Log failure System
or critical event.
Health

Sys Event
Log

Critical

SubCategory

Severity

Security Information
2387

Security information.

Security Failure
2385

Table 29-22. System Event Log Traps
TrapID Description
Category
System Event Log Information
2379

System Event Log
information.

System Event Log Warning
2378

System Event Log
warning.

System Event Log Failure
2377

Table 29-23. Temperature Probe Traps
TrapID Description
Category
Temperature Probe Normal
2163

Temperature sensor
value is within range.

System
Health

Temperature Informational

Temperature Probe Warning
2162

Temperature sensor has System
detected a warning value. Health

Temperature Minor

Temperature Probe Failure
2161

Temperature sensor has
detected a failure value.

System
Health

Temperature Critical

iDRAC7 MIB

789

Table 29-24. Temperature Statistics Traps
TrapID Description
Category

SubCategory

Severity

Temperature Statistics Warning
2522

Temperature has been
System
above the warning or
Health
critical threshold level for
a long enough period of
time to be considered in
a warning state.

Temperature Minor
Statistics

Temperature Statistics Failure
2521

Temperature has been
System
above the warning or
Health
critical threshold level for
a long enough period of
time to be considered in
a critical state.

Table 29-25. vFlash Media Device Traps
TrapID Description
Category

Temperature Critical
Statistics

SubCategory

Severity

vFlash Media Device Information
2507

vFlash Media device
information.

System
Health

vFlash Event Informational

System
Health

vFlash Event Minor

System
Health

vFlash Event Critical

vFlash Media Device Warning
2506

vFlash Media device
warning.

vFlash Media Device Failure
2505

vFlash Media device
failure.

Table 29-26. vFlash Media Device Absent Trap
TrapID Description
Category
SubCategory

Severity

vFlash Media Device Absent
2515

790

vFlash Media device is
absent.

iDRAC7 MIB

System
Health

vFlash
Absent

Informational

Table 29-27. Voltage Probe Traps
TrapID Description
Category

SubCategory

Severity

Voltage

Informational

Voltage

Minor

Voltage

Critical

Voltage Probe Normal
2171

Voltage sensor reading is System
within range.
Health

Voltage Probe Warning
2170

Voltage sensor has
System
detected a warning value. Health

Voltage Probe Failure
2169

Voltage sensor has
detected a failure value.

System
Health

Storage Trap Group
The Storage Trap Group contains traps that fall under the Storage event
category of iDRAC7. Storage traps are traps generated in response to events
related to the external storage subsystem of the system in which iDRAC7
resides.

iDRAC7 MIB

791

Table 29-28. Battery Traps
TrapID Description

Category

SubCategory

Severity

Storage

Battery Event Informational

Storage

Battery Event Minor

Storage

Battery Event Critical

Category

SubCategory

Severity

Storage

Storage
Contr

Informational

Storage

Storage
Contr

Minor

Storage

Storage
Contr

Critical

Category

SubCategory

Severity

Storage

Storage
Enclosr

Informational

Storage

Storage
Enclosr

Minor

Battery Normal
4275

Battery state has
returned to normal; or
battery presence has
been detected.

Battery Warning
4274

Battery is low.

Battery Failure
4273

Battery has failed or
battery is absent.

Table 29-29. Controller Traps
TrapID Description
Storage Controller Information
4331

Controller information.

Storage Controller Warning
4330

Controller warning.

Storage Controller Failure
4329

Controller failure.

Table 29-30. Enclosure Traps
TrapID Description
Storage Enclosure Information
4339

Enclosure information.

Storage Enclosure Warning
4338

792

Enclosure warning.

iDRAC7 MIB

TrapID Description

Category

SubCategory

Severity

Storage

Storage
Enclosr

Critical

Storage Enclosure Failure
4337

Enclosure failure.

iDRAC7 MIB

793

Table 29-31. Fan Traps
TrapID Description

Category

SubCategory

Severity

Storage

Fan Event

Informational

Storage

Fan Event

Minor

Storage

Fan Event

Critical

SubCategory

Severity

Storage Fan Information
4203

Fan information.

Storage Fan Warning
4202

Fan warning.

Storage Fan Failure
4201

Fan failure.

Table 29-32. Physical Disk Traps
TrapID Description
Category
Storage Physical Disk Information
4347

Physical disk
information.

Storage

Physical Disk Informational

Storage

Physical Disk Minor

Storage

Physical Disk Critical

Storage Physical Disk Warning
4346

Physical disk warning.

Storage Physical Disk Failure
4345

Physical disk failure.

Table 29-33. Power Supply Traps
TrapID Description
Category

SubCategory

Severity

Storage Power Supply Information
4235

Power supply
information.

Storage

Power Supply Informational

Storage

Power Supply Minor

Storage

Power Supply Critical

Storage Power Supply Warning
4234

Power supply warning.

Storage Power Supply Failure
4233

794

Power supply failure.

iDRAC7 MIB

Table 29-34. Storage Management Status Traps
TrapID Description
Category
SubCategory

Severity

Storage Management Information
4179

Storage Management
Storage
information. There is no
global status change
associated with this trap.

Storage

Informational

Storage

Minor

Storage

Critical

SubCategory

Severity

Storage Management Warning
4178

Storage Management has Storage
detected a device
independent warning
condition. There is no
global status change
associated with this trap.

Storage Management Failure
4177

Storage Management has Storage
detected a device
independent error
condition. There is no
global status change
associated with this trap.

Table 29-35. Temperature Probe Traps
TrapID Description
Category
Storage Temperature Probe Information
4211

Temperature probe
information.

Storage

Temperature Informational

Storage Temperature Probe Warning
4210

Temperature probe
warning.

Storage

Temperature Minor

Storage

Temperature Critical

Storage Temperature Probe Failure
4209

Temperature probe
failure.

iDRAC7 MIB

795

Table 29-36. Virtual Disk Trap
TrapID Description

Category

SubCategory

Severity

Virtual Disk

Informational

Storage

Virtual Disk

Minor

Storage

Virtual Disk

Critical

Storage VirtualDisk Information
4355

Virtual disk information. Storage

Storage Virtual Disk Warning
4354

Virtual disk warning.

Storage Virtual Disk Failure
4353

Virtual disk failure.

Updates Trap Group
The Updates Trap Group contains traps that fall under the Updates event
category of iDRAC7. Updates traps are traps generated in response to events
related to firmware/driver upgrades/downgrades.
NOTE: Currently there are no Update traps.

Audit Trap Group
The Audit Trap Group contains traps that fall under the Audit event category
of iDRAC7. Audit traps are traps generated in response to audit-type events
of iDRAC7, such as authorizing of debugging, changes to iDRAC7 license
state, power state changes, etc.

796

iDRAC7 MIB

Table 29-37. Debug Traps
TrapID Description

Category

SubCategory

Severity

Audit

Debug

Informational

Audit

Debug

Minor

SubCategory

Severity

Audit

DRAC IP
Address

Informational

Category

SubCategory

Severity

Audit

Licensing

Informational

Audit

Licensing

Minor

Audit

Licensing

Critical

Debug Information
8595

Debug authorized.

DebugWarning
8594

Debug authorization
failed.

Table 29-38. iDRAC IP Address Change Trap
TrapID Description
Category
iDRAC IP Address Change
8499

iDRAC IP address has
changed.

Table 29-39. License Traps
TrapID Description
License Information
8515

License information.

License Warning
8514

License warning.

License Failure
8513

License failure.

Table 29-40. System Power State Change Trap
TrapID Description
Category
SubCategory

Severity

System Power State Change Information
8579

Host is going through a
power state change
(powering on or
powering off).

Audit

System Info

Informational

Configuration Trap Group
The Configuration Trap Group contains traps that fall under the
iDRAC7 MIB

797

Configuration event category of the iDRAC7. Configuration traps are traps
generated in response to events related to hardware configuration changes
and software configuration changes.
Table 29-41. Test Trap
TrapID Description

Category

SubCategory

Severity

Test Trap Event
10395 The iDRAC generated a Configuratio Test Alert
test trap event in
n
response to a user
request.

798

iDRAC7 MIB

Informational

iDRAC7 MIB

799

800

iDRAC7 MIB

30

Standard Data Type Definitions

This appendix contains definitions for data types that are standard in most
contexts across the information technology industry. These are the most
common data types for describing variable values defined in the 10892.mib,
dcs3rmt.mib and dcs3fru.mib files. Server Administrator-specific variable
values are defined in the last section of the section in which they are
introduced.

Common Data Types
Common data types include several types of strings, the object range, signed
and unsigned bit ranges, and the familiar Boolean (true or false) data type.
Table 30-1.

Common Data Types

Variable Name:

Definition

DellString

DisplayString (SIZE (0..64))

DellSecurityString

DisplayString (SIZE (0..255))

DellCostofOwnershipString DisplayString (SIZE (0..64))
DellObjectRange

INTEGER (1..128)

DellUnsigned8BitRange

INTEGER (1..256)

DellUnsigned16BitRange

INTEGER (1..65535)

DellUnsigned32BitRange

INTEGER (1..2147483647)

DellSigned32BitRange

INTEGER (-2147483647..2147483647)

DellBoolean

INTEGER (0..1 (FALSE = 0, TRUE = 1))

Standard Data Type Definitions

801

Variables with Data Types of State Capabilities
and State Capabilities Unique
Variables with definitions of StateCapabilities or
StateCapabilitiesUnique are integers
representing a series of bit definitions. They are NOT enumerations and
should be treated as bit fields. The value is passed as a decimal value.
The decimal value should be converted to hex and the appropriate bits should
be parsed from hex. Some of the more common bit combinations are defined
in some variables, but not all combinations are or will be defined.
Table 30-2. Dell State Capabilities
Variable Name: DellStateCapabilities
Data Type: Integer
Possible Data Values

Meaning of Data Value

if set to zero(0)

The object has no capabilities.

unknownCapabilities(1)

The object’s capabilities are unknown.

enableCapable(2)

The object can be disabled (offline, a
binary 0 value) or enabled (online, a
binary 1 value).

notReadyCapable(4)

The object is not ready.

enableAndNotReadyCapable Enable and not ready capable.
(6)

802

Standard Data Type Definitions

Table 30-3.

Dell State Settings

Variable Name: DellStateSettings
Data Type: Integer
Possible Data Values

Meaning of Data Value

if set to zero(0)

The object has no settings capabilities and
its state is disabled.

unknown(1)

The object’s state is unknown.

enabled(2)

The object’s state is disabled (offline, a
binary 0 value) or enabled (online, a binary
1 value).

notReady(4)

The object is not ready.

enableAndNotReady(6)

The object is enabled and not ready.

Table 30-4.

Dell Probe Capabilities

Variable Name: DellProbeCapabilities
Data Type: Integer
Possible Data Values

Meaning of Data Value

if set to zero(0)

The object has no capabilities.

upperNonCriticalThresholdSet The upper noncritical threshold
can be set.
Capable(1)
lowerNonCriticalThresholdSet The lower noncritical threshold
can be set.
Capable(2)
upperNonCriticalThresholdDef The upper noncritical threshold
can be set to default.
aultCapable(4)
lowerNonCriticalThresholdDef The lower noncritical threshold
can be set to default.
aultCapable(8)

Standard Data Type Definitions

803

Dell Status Data Types
Status data types include DellStatus, DellStatusRedundancy, and
DellStatusProbe.
Table 30-5. Dell Status
Variable Name: DellStatus
Data Type: Integer
Possible Data Values

Meaning of Data Value

other(1)

The object’s status is not one of the following:

unknown(2)

The object’s status is unknown.

ok(3)

The object’s status is OK.

nonCritical(4)

The object’s status is warning, noncritical.

critical(5)

The object’s status is critical (failure).

nonRecoverable(6)

The object’s status is nonrecoverable (dead).

Table 30-6. Dell Status Redundancy
Variable Name: DellStatusRedundancy
Data Type: Integer
Possible Data Values

Meaning of Data Value

other(1)

The object’s status is not one of the following:

unknown(2)

The object’s redundancy status is unknown.

full(3)

The object is fully redundant.

degraded(4)

The object’s redundancy has been degraded.

lost(5)

The object’s redundancy has been lost.

notRedundant(6)

Redundancy does not apply or it is not redundant.

804

Standard Data Type Definitions

Table 30-7.

Dell Status Probe

Variable Name: DellStatusProbe
Data Type: Integer
Possible Data Values

Meaning of Data Value

other(1)

The object’s status is not one of the following:

unknown(2)

The status of the object is unknown.

ok(3)

The status of the object is OK.

nonCriticalUpper(4)

The object is at the noncritical upper limit.

CriticalUpper(5)

The object is at the critical upper limit.

nonRecoverableUpper(6) The object is at the nonrecoverable upper limit.
nonCriticalLower(7)

The object is at the noncritical lower limit.

criticalLower(8)

The object is at the critical lower limit.

nonRecoverableLower(9) The object is at the nonrecoverable lower limit.
failed(10)

The status of the object is failed.

Dell Date
Variable Name: DellDate
Data Type: DellUnsigned64BitRange

Octet String (SIZE(8))

The DellDate definition is required because SNMP V1 does not support 64-bit
ranges. The information sent back by this subagent has the most significant
byte of the information as the first byte. For example, the hex address
0x1029384754657687 is sent as hex: 0001 0000 0010 1001 0011 1000 0100
0111 ... Byte 1 Byte 2 Byte 3 Byte 4.

Standard Data Type Definitions

805

Full Dates
Variable Name: DellDateName
Data Type: DisplayString

DisplayString (SIZE (25))

Full dates are defined in the ASCII format:
yyyyMMddhhmmss.uuuuuu+fff or yyyyMMddhhmmss.uuuuuu-fff
where yyyy is the year, MM is the month, dd is the day, hh are the hours, mm
are the minutes, and ss are the seconds. uuuuuu is the number of
microseconds, and +fff or
-fff is the offset from UTC in minutes. For example, Friday, October 31, 2001,
at 6:05:19 PM CST would be represented as 20011031180519.000000-360.
The values are zero-padded, and if a valid value for a field is not deliverable,
each character in the field is replaced with an asterisk (*) character.

806

Standard Data Type Definitions

31

SNMP Sample Output

This appendix contains the sample output from the Simple Network
Management Protocol (SNMP) covering the first four groups of the
Instrumentation management information base (MIB) sample output from
the Simple Network Management Protocol (SNMP) covers the first four
groups of the Instrumentation management information base (MIB). Values
are shown for each object identifier (OID) in the Instrumentation MIB
Version Group, the Systems Management Software Group, the System State
Group, the Chassis Information Table, and Event Log Table. The data is from
a Dell PowerEdge 2650 system.
Walk .1.3.6.1.4.1.674.10892
Community: 'public')

(Agent: 'SERVER01',

.iso.org.dod.internet.private.enterprises.dell.server3
1.3.6.1.4.1.674.10892.1.1.1.0

=

5

1.3.6.1.4.1.674.10892.1.1.2.0

=

3

1.3.6.1.4.1.674.10892.1.1.3.0

=

0

1.3.6.1.4.1.674.10892.1.100.1.0
Administrator'

=

'Server

1.3.6.1.4.1.674.10892.1.100.2.0

=

'5.3.0'

1.3.6.1.4.1.674.10892.1.100.3.0

=

4522

1.3.6.1.4.1.674.10892.1.100.4.0
software for Dell systems.'

=

'Management

1.3.6.1.4.1.674.10892.1.100.5.0

=

1

1.3.6.1.4.1.674.10892.1.100.6.0

=

1

1.3.6.1.4.1.674.10892.1.100.7.0

=

'No Updates'

SNMP Sample Output

807

1.3.6.1.4.1.674.10892.1.100.8.0
'https://1.2.3.4:1311'

=

1.3.6.1.4.1.674.10892.1.100.9.0

=

'en_US'

1.3.6.1.4.1.674.10892.1.100.10.0

=

'2.2.0'

1.3.6.1.4.1.674.10892.1.100.11.0

=

0

1.3.6.1.4.1.674.10892.1.100.12.0

=

1

1.3.6.1.4.1.674.10892.1.100.13.0

=

'Dell Inc.'

1.3.6.1.4.1.674.10892.1.200.10.1.1.1

=

1

1.3.6.1.4.1.674.10892.1.200.10.1.2.1

=

3

1.3.6.1.4.1.674.10892.1.200.10.1.3.1

=

2

1.3.6.1.4.1.674.10892.1.200.10.1.4.1

=

3

1.3.6.1.4.1.674.10892.1.200.10.1.5.1

=

'\02'

1.3.6.1.4.1.674.10892.1.200.10.1.6.1

=

3

1.3.6.1.4.1.674.10892.1.200.10.1.7.1

=

'\03'

1.3.6.1.4.1.674.10892.1.200.10.1.8.1

=

'\02\02'

1.3.6.1.4.1.674.10892.1.200.10.1.9.1

=

3

1.3.6.1.4.1.674.10892.1.200.10.1.10.1

=

'\03\03'

1.3.6.1.4.1.674.10892.1.200.10.1.11.1 =
'\02\02\02\02\02\02\02\02\02\02\02\02\02\02\02\02\02\
02\02\02'
1.3.6.1.4.1.674.10892.1.200.10.1.12.1

=

3

1.3.6.1.4.1.674.10892.1.200.10.1.13.1 =
'\03\03\03\03\03\03\03\03\03\03\03\03\03\03\03\03\03\
03\03\03'
1.3.6.1.4.1.674.10892.1.200.10.1.20.1
'\02\02\02\02\02'

=

1.3.6.1.4.1.674.10892.1.200.10.1.21.1

=

808

SNMP Sample Output

3

1.3.6.1.4.1.674.10892.1.200.10.1.22.1
'\03\03\03\03\03'

=

1.3.6.1.4.1.674.10892.1.200.10.1.23.1
'\02\02\02\02\02\02'

=

1.3.6.1.4.1.674.10892.1.200.10.1.24.1

=

1.3.6.1.4.1.674.10892.1.200.10.1.25.1
'\03\03\03\03\03\03'

=

1.3.6.1.4.1.674.10892.1.200.10.1.26.1
'\02\02\02\02'

=

1.3.6.1.4.1.674.10892.1.200.10.1.27.1

=

1.3.6.1.4.1.674.10892.1.200.10.1.28.1
'\03\03\03\03'

=

1.3.6.1.4.1.674.10892.1.200.10.1.29.1

=

'\02'

1.3.6.1.4.1.674.10892.1.200.10.1.30.1

=

3

1.3.6.1.4.1.674.10892.1.200.10.1.31.1

=

'\03'

1.3.6.1.4.1.674.10892.1.200.10.1.41.1

=

3

1.3.6.1.4.1.674.10892.1.200.10.1.42.1

=

3

1.3.6.1.4.1.674.10892.1.200.10.1.43.1

=

'\03'

3

3

1.3.6.1.4.1.674.10892.1.300.10.1.1.1

=

1

1.3.6.1.4.1.674.10892.1.300.10.1.2.1

=

0

1.3.6.1.4.1.674.10892.1.300.10.1.3.1

=

2

1.3.6.1.4.1.674.10892.1.300.10.1.4.1

=

3

1.3.6.1.4.1.674.10892.1.300.10.1.5.1

=

0

1.3.6.1.4.1.674.10892.1.300.10.1.6.1

=

23

1.3.6.1.4.1.674.10892.1.300.10.1.7.1
Chassis'

=

'Main System

1.3.6.1.4.1.674.10892.1.300.10.1.8.1

=

'Dell Inc.'

SNMP Sample Output

809

1.3.6.1.4.1.674.10892.1.300.10.1.9.1
2650'

=

'PowerEdge

1.3.6.1.4.1.674.10892.1.300.10.1.10.1

=

'ASSETTAG'

1.3.6.1.4.1.674.10892.1.300.10.1.11.1

=

'1234567'

1.3.6.1.4.1.674.10892.1.300.10.1.12.1

=

254

1.3.6.1.4.1.674.10892.1.300.10.1.13.1

=

289

1.3.6.1.4.1.674.10892.1.300.10.1.14.1

=

4

1.3.6.1.4.1.674.10892.1.300.10.1.15.1

=

'SERVER01'

1.3.6.1.4.1.674.10892.1.300.10.1.16.1
'20050513095213.000000-360'

=

1.3.6.1.4.1.674.10892.1.300.10.1.17.1
'20050513100052.000000-360'

=

1.3.6.1.4.1.674.10892.1.300.10.1.18.1
the value'

=

'Please set

1.3.6.1.4.1.674.10892.1.300.10.1.19.1
the value'

=

'Please set

1.3.6.1.4.1.674.10892.1.300.10.1.20.1
the value'

=

'Please set

1.3.6.1.4.1.674.10892.1.300.10.1.21.1

=

3

1.3.6.1.4.1.674.10892.1.300.10.1.22.1

=

0

1.3.6.1.4.1.674.10892.1.300.10.1.23.1

=

0

1.3.6.1.4.1.674.10892.1.300.10.1.24.1

=

0

1.3.6.1.4.1.674.10892.1.300.10.1.25.1

=

0

1.3.6.1.4.1.674.10892.1.300.10.1.26.1

=

0

1.3.6.1.4.1.674.10892.1.300.10.1.27.1

=

0

1.3.6.1.4.1.674.10892.1.300.10.1.28.1

=

8

1.3.6.1.4.1.674.10892.1.300.10.1.29.1

=

2

1.3.6.1.4.1.674.10892.1.300.10.1.30.1

=

1

810

SNMP Sample Output

1.3.6.1.4.1.674.10892.1.300.10.1.31.1

=

15

1.3.6.1.4.1.674.10892.1.300.10.1.32.1

=

0

1.3.6.1.4.1.674.10892.1.300.10.1.33.1

=

27

1.3.6.1.4.1.674.10892.1.300.10.1.34.1

=

0

1.3.6.1.4.1.674.10892.1.300.10.1.35.1

=

1

1.3.6.1.4.1.674.10892.1.300.10.1.36.1

=

480

1.3.6.1.4.1.674.10892.1.300.10.1.37.1

=

1

1.3.6.1.4.1.674.10892.1.300.10.1.38.1

=

2

1.3.6.1.4.1.674.10892.1.300.10.1.39.1

=

2

1.3.6.1.4.1.674.10892.1.300.10.1.44.1

=

0

1.3.6.1.4.1.674.10892.1.300.10.1.45.1

=

0

1.3.6.1.4.1.674.10892.1.300.40.1.1.1.1

=

1

1.3.6.1.4.1.674.10892.1.300.40.1.2.1.1

=

1

1.3.6.1.4.1.674.10892.1.300.40.1.3.1.1

=

8

1.3.6.1.4.1.674.10892.1.300.40.1.4.1.1

=

2

1.3.6.1.4.1.674.10892.1.300.40.1.5.1.1
cleared'

=

'Log

1.3.6.1.4.1.674.10892.1.300.40.1.6.1.1

=

2

1.3.6.1.4.1.674.10892.1.300.40.1.7.1.1

=

3

1.3.6.1.4.1.674.10892.1.300.40.1.8.1.1
'20050513100047.000000-360'

=

SNMP Sample Output

811

812

SNMP Sample Output

Index
Numerics
1403, 743

BIOS Setup Control Group, 391
variable values, 420

1404, 744
1602, 748

C

1603, 748

Change, 685

1604, 748

Change Management
Group, 685

1651, 749
1653, 749

Cluster Group, 529
Cluster Table, 529
variable values, 532

A

Cost of Ownership Group
COO Cost Event Log Table, 452
COO Lease Information
Table, 456
COO Maintenance Table, 462
COO Options Table, 460
COO Repair Table, 464
COO Schedule Number
Table, 459
COO Service Contract Table, 450
COO Support Information
Table, 466
COO Trouble Ticket Table, 468
COO Warranty Table, 454
Cost of Ownership Table, 439
Cost of Ownership tables, 439

Application, 688
Application Group, 688

B
BIOS Group
BIOS Setup Control Table, 391
Diskette Control Table, 412
IDE Control Table, 410
Network Interface Control
Table, 414
Parallel Port Control Table, 404
SCSI Control Table, 402
Serial Port Control Table, 406
USB Control Table, 408
BIOS Group tables, 391

Index

813

D

E

data types
common, 801
state capabilities, 802
state settings, 803
status, 804
status probe, 805
status redundancy, 804

Event Log
viewing entries, 764

Dell RAC Out-of-Band
Group, 695
Chassis Alerts, 716
Chassis Power, 709
Chassis Status, 699
CMC Power Information, 710
CMC PSU Information, 714
Legacy Alerting, 718
Product Information, 695
Device added to system, 749
Device configuration error
detected, 749
Device Group, 686
Cache Device Table, 279
Generic Device Table, 296
Keyboard Device Table, 266
Memory Device Mapped Address
Table, 293
Memory Device Table, 285
PCI Device Configuration Space
Table, 302
PCI Device Table, 299
Pointing Device Table, 264
Processor Device Table, 269
variable values, 322

814

Index

G
Global Data Group, 558

I
Introduction
Server Administrator Change
Management MIB, 23
Server Administrator
Instrumentation MIB, 18
Server Administrator Remote
Access MIB, 21
Server Administrator Storage
Management MIB, 22
Inventory, 685
Inventory Group, 685

L
Local Response Agent Group
LRA Action Table, 434
LRA Global Settings, 431
LRA Global Settings Table, 432
variable values, 436
Local Response Agent Group
tables, 431
Logical Devices Group, 669

M

Memory Device Port Table, 238
Monitor Port Table, 241
Parallel Port Table, 246
Pointing Port Table, 229
Processor Port Table, 235
Serial Port Table, 250
Small Computer System Interface
Port Table, 244
variable values, 257

Memory device correction rate
crossed a warning
threshold, 743
Memory device ECC Correctable
error count crossed a warning
threshold, 743
Memory Group
Physical Memory Tables, 365
variable values, 374, 381
Memory Group Variable
Values, 385
MIB
minor version number, 42
MIB Major Version Number, 41

O
Operating System Group, 691
Memory Table, 125
Operating System Table, 123
Operating System Memory
Table, 125

P
Physical Devices Group, 564
Physical Memory Card
Table, 382
Pluggable Device Traps, 749
Port Group
Keyboard Port Table, 232

Power Group
AC Power Cord Table, 173
AC Power Switch Table, 171
Amperage Probe Table, 165
Battery Table, 176
Power Supply Table, 156
Power Unit Table, 153
Power Usage Table, 178
variable values, 187
Voltage Probe Table, 160
Power Group tables, 153
Processor Device Status
Traps, 747
Processor sensor detected a
failure value, 748
Processor sensor detected a
warning value, 748
Processor sensor returned to a
normal state, 748

R
Redundant Memory Unit
Table, 379

Index

815

Remote Access Group
Remote Access Table, 480
Remote SNMP Trap Table, 497
Remote User Administration
Table, 489
Remote User Dial-In
Configuration Table, 506
Remote User Dial-Out Table, 509
Remote Flash BIOS Group
variable values, 226

S
sample SNMP output, 807
Slot Group
System Slot Table, 351
variable values, 355
SNMP
introduction to, 33
SNMP MIB OIDs, 35
SNMP security, 36
SNMP traps, 37
SNMP basic terminology
fields, 27-28
managed object, 26
MIB, 26
SNMP, 25
variable, 26
SNMP support, configuring, 765
SNMP tables, 29
example, 29
reference guide content, 31, 36
SNMP traps, 767
816

Index

Storage Management Event
Group, 683
Storage Management
Information Group, 557
System Resource Group
Direct Memory Access Table, 145
Input/Output Port Table, 136
Interrupt Table, 142
Map Table, 131
Memory Table, 139
Owner Table, 133
variable values, 148
System State Table, 49, 51, 351
systems management
software, 43
build number systems, 44
description name, 44
name, 44-46
preferred protocol, 45
supported protocol, 45
version number name, 44

T
Thermal Group
Cooling Device Table, 203
Cooling Unit Table, 201
Temperature Probe Table, 209
variable values, 215
trap variables, 721
current status, 722
data, 723
message, 722
previous status, 723

system, 722
table index OID, 722
traps, 728
AC power cord traps, 746
amperage probe traps, 737
chassis intrusion traps, 739
cooling device traps, 733
fan enclosure traps, 744
hardware log traps, 747
memory device traps, 743
miscellaneous traps, 729
power supply traps, 742
redundancy unit traps, 740
temperature probe traps, 731
understanding the trap
descriptions, 723
understanding trap severity, 727
voltage probe traps, 735

U
User Security Table, 219, 223

V
variable names
capability, 28
settings, 28
state, 28
status, 28
Viewing
SNMP traps, 767

Index

817

818

Index



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Format                          : application/pdf
Creator                         : Dell Inc.
Title                           : Dell OpenManage Server Administrator Version 7.1 SNMP Reference Guide
Subject                         : Reference Guide4
Description                     : Reference Guide4
Producer                        : Acrobat Distiller 10.0.1 (Windows); modified using iTextSharp 5.1.3 (c) 1T3XT BVBA
Keywords                        : esuprt_electronics#esuprt_software#Dell OpenManage Server Administrator Version 7.1#dell-opnmang-srvr-admin-v7.1#Reference Guide4
Create Date                     : 2012:06:26 11:57:39Z
Creator Tool                    : FrameMaker 7.1
Modify Date                     : 2013:12:24 12:39:34-06:00
Page Mode                       : UseOutlines
Page Count                      : 818
Author                          : Dell Inc.
Productcode                     : dell-opnmang-srvr-admin-v7.1
Typecode                        : rg4
Typedescription                 : Reference Guide4
Languagecodes                   : en-us
Sectioncode                     : 
Sectiondescription              : 
Publishdate                     : 2012-06-26 00:00:00
Expirydate                      : 9999-09-09 00:00:00
Manualurl                       : http://ftp.dell.com/manuals/all-products/esuprt_electronics/esuprt_software/esuprt_ent_sys_mgmt/dell-opnmang-srvr-admin-v7.1_Reference Guide4_en-us.pdf
Readytocopy                     : false
Futureproductindication         : No
Categorypathforfutureproducts   : 
Businesskeywords                : 
Filesize                        : 2084
Creationdate                    : D:20120626115739Z
Moddate                         : D:20121119092712-06'00'
EXIF Metadata provided by EXIF.tools

Navigation menu