Dell Openmanage Baseboard Management Controller Version 4 6 Owners Manual 4.6 Readme
2014-11-13
: Dell Dell-Openmanage-Baseboard-Management-Controller-Version-4-6-Owners-Manual-118044 dell-openmanage-baseboard-management-controller-version-4-6-owners-manual-118044 dell pdf
Open the PDF directly: View PDF .
Page Count: 6
Dell(TM) OpenManage(TM)
Baseboard Management
Controller Management
Utility
Version 4.6
Readme
NOTE:
This readme provides information about the Dell OpenManage Baseboard Management Controller (BMC)
Management Utility version 4.6.
NOTE:
See the Server Administrator readme ("readme_sa.txt") or the installation readme ("readme_ins.txt") on the "Dell
Systems Management Tools and Documentation” DVD for the latest information and issues specifically related to Server
Administrator.
This file contains the following sections:
Criticality
Supported Systems
Release Highlights
User Notes
Known Issues
Criticality
3 - Optional
Optional = It is recommended that you review the specifics about the update to determine if it applies to your system. The
update contains changes that impact only certain configurations, or provides new features that may or may not apply to
your environment.
Supported Systems
The Dell OpenManage Baseboard Management Controller Management Utility supports the following Dell systems:
T620, R620, M620, R720, R720xd,
T210, T310, R310, T410, R410, R510, T610, R610, R710, T710, R810,
R815, R910,
800, 830, 840, 850, 860, SC1425, SC1435, 1800, 1850, 1855, 1900, 1950, 1955, 2800, 2850, 2900, 2950, 2970, 6800, 6850,
6950, T105, R805, R900, R710, R610, T710, M610, M710, Dell PowerVault(TM) NX1950, PowerVault 100, PowerVault 500,
PowerVault 600.
NOTE:
All references in this document to PowerEdge(TM) 840, 2950, and 2900 also apply to the PowerVault 100, PowerVault
500, and PowerVault 600 systems respectively.
NOTE:
For a complete list of supported operating systems, see the “Dell Systems Software Support Matrix” located on the
“
Dell Systems Management Tools and Documentation
” DVD or on the Dell support website at “
support.dell.com
”.
Release Highlights
Support for licensing on selected iDRAC components.
Support for enhancements on Shared LOMs
User Notes
This section provides information to help enhance your experience with your systems management software in particular
implementations and environments.
Notes For The BMC Management Utilities
Installation and Configuration Notes
Web browsers allow connecting to alternate ports including the Serial Over LAN (SOL) Proxy on IP port 623. If you
connect from a Web browser, the data received from SOL Proxy will be jumbled, as the IP port implements the
telnet protocol rather than the HTTP or FTP. For correct results, close the Web session and connect to SOL Proxy
using a telnet program.
On initiating a console redirection session using SOL Proxy while loading the Microsoft Windows operating system,
you may not be able to send data to the serial port. As Windows can block the writing of data to the serial port,
you may receive the following message on attempting to send data using keyboard input:
"SOL not able to write to the system serial port."
The SOL session closes after displaying this message. The main SOL menu displays to reconnect (or reconfigure
settings).
You can manage a system by accessing multiple IPMI instances at the same time as long as the BMC of the system
supports more than one concurrent connection. However, multiple sessions can lead to session failures under high
network traffic.
When attempting to gracefully shutdown a system running Novell NetWare or Red Hat Linux through SOL Proxy,
you may receive a message stating that the system is unable to power off the server because the
power_off_timeout
was reached. The
power_off_timeout
value specifies the time in seconds that SOL Proxy
polls for the power status of the managed system and set to a default value of 60 seconds. If your managed system
is running a supported NetWare or Red Hat Linux operating system, it may take more than 60 seconds for the
operating system to complete the graceful shutdown. To avoid this, change the
power_off_timeout
parameter in
the
solproxy.cfg
file to a higher value, such as 90 seconds.
To configure the BIOS settings for SOL Proxy for the Dell PowerEdge 1855, there is no option to set the
Serial Port
1
field for
Integrated Devices
. Instead, navigate to the
Console Redirection
field and set it to
BMC SOL
. You can
then configure the
Failsafe Baud Rate
and
Remote Terminal Type
settings, if applicable.
Using a direct connect cable with some 3COM 3C905-TX based network interface controller (NIC) adapters
(including the 3C920), you may experience problems keeping the SOL connection active when performing a reboot
and activate operation. Some drivers for the 3C9xx series of adapters include an intentional cable detect delay
that can exceed 10 seconds by default. You can correct it by editing the advanced properties of the NIC adapter
and decreasing the values for
Cable Hold Off Timer
and
Cable To Detect Timer
.
If your network switch has the
Spanning Tree
feature enabled, and if you experience out of sequence packets or
connection timeout errors, it is often due to the long delays experienced when the
Spanning Tree
feature is
analyzing the network. Turn off the
Spanning Tree
feature to avoid long reconnection times. Alternately, you can
edit
solproxy.cfg
and increase the retry_interval to 10. The exact value depends on the specific network and how
long the spanning tree requires to complete its job. Restart the SOL Proxy service for the changes to take effect.
The SOL Proxy server is unable to start a console redirection session from the Windows command prompt (To
access the Windows command prompt, Click ->
Start
->
Run
, and then type
cmd.exe
in the
Run
dialog box). The
following message is displayed on the management station:
"SOL not able to write to the system serial port."
Cause: Console redirection is not enabled in the BIOS setup.
The Linux operating system shell prompt has a path cache that can under some circumstances cause a different
ipmish to be invoked, if ipmish is executed immediately after it is installed. To resolve this, type
hash -r
at the
same shell prompt to clear the cache and then execute ipmish.
To run ipmitool inband on Windows 2003 R2 systems, the Windows
IPMI driver needs to be installed. For
instructions on how to
install the driver,
see:
http://technet2.microsoft.com/ windowsserver/en/library /8c6c90e8-16b8-4d51-bf1e-
efad5f5a61081033.mspx?mfr=true
Running ipmitool on Linux systems requires the OpenIPMI driver to be installed and running. Use the command
service ipmi start
to start the ipmi service at runtime, and
chkconfig ipmi on
to start the services automatically
at boot.
While running the delloem LCD feature option- userdefined string,
you may face an issue while setting the
userdefined
string that contains the character '&&' on Windows system.
Define the string in "" to avoid this issue.
Known Issues
This section provides information concerning open issues with systems
management software.
Issues For Dell PowerEdge 1855 System
The following apply only for the Dell PowerEdge 1855 system:
Any host application that communicates with port 623 cannot be executed from LOM_1 (the first one) of a server
module. If you attempt this, the network packets will be sent to the BMC instead of the host. So use LOM_2, and
ensure that the IP address, IP subnet mask, and the gateway settings for the LOM_1 and the BMC match to prevent
possible network disruptions.
The following subsection explains how to identify and resolve a
possible IP address conflict.
Problem:
An "IP address conflict" message is displayed after assigning identical IP addresses to Local Area Connection and the BMC as
instructed.
Cause:
When the operating system first detects hardware devices such as the onboard network adapters, the order in which the
devices are enumerated is not guaranteed. Therefore, LOM_1 (the first one) may be assigned Local Area Connection #2 and
LOM_2 may be assigned Local Area Connection #1. Due to this switch, when you assign identical addresses to the BMC and
Local Area Connection, identical addresses are being assigned to the BMC and LOM_2. This creates the IP address conflict.
NOTE
: The lower-number MAC address will be LOM_1.
Workaround:
Click
Start
->
Network Connections
. On Network Connections page click
View
->
Details
. This will display the Local Area
Connections information. Right-click
Local Area Connection
and rename it as
Local Area Connection #2
. Rename the
existing
Local Area Connection #2
to
Local Area Connection
. This ensures that the Local Area Connection names match
with the correct onboard NICs. Then assign identical IP addresses to Local Area Connection and the BMC.
Issues For The BMC Management Utilities
The Special Administration Console (SAC) is not supported with ipmitool SOL on the Microsoft Windows Server 2008
Enterprise (x64) edition.
Going forward ipmish and SOL proxy will not be undergoing any feature changes, IPMITool will be used on all
supported Dell systems.
After IPMISH is installed, if you open a command prompt and type
ipmish
without being in the "
C:\Program
Files\Dell\SysMgt\bmc
" directory, you will receive an error stating that the command could not be found. This is
because, by default, the IPMISH directory is not added to the system path. You must either manually add the
system path to the command line, or go to the specified directory before running the IPMISH application.
Microsoft SAC does not implement hardware control flow. Therefore, when console redirection is enabled with EMS
SAC, you will see corrupted data. Use lower baud rates to effectively use SOL Proxy under redirection to EMS SAC.
While performing console redirection through SOL Proxy, you may see a few garbled characters. This occurs while
the SOL Proxy server refreshes the screen.
You can verify your redirected output by using the same telnet client over the serial port to ensure that your
telnet client supports console redirection features. If you see the same garbled text through the serial port, you
may use another telnet client for better performance.
If you issue the graceful shutdown command using SOL Proxy option 4 (Reboot and Activate Console Redirection)
on a system running Microsoft Windows 2000 with an ACPI-compliant BIOS, Windows performs an emergency
shutdown instead of a graceful shutdown. Windows does not send WM_QUERYENDSESSION and WM_ENDSESSION
messages to the running programs; therefore, the programs cannot notify the user to save data and quit gracefully.
This could result in data corruption or data loss.
Storage controllers from PERC 4 and earlier use CTRL+M to enter configuration during BIOS POST. This is the same
ASCII value normally set by the ENTER key. In a SOL session, CTRL+M will not behave as expected during boot. Use
ESC+CTRL+M to enter PERC 4 setup.
Alternate key strokes are provided as BIOS starts up for a number of special keys. See the "
Dell OpenManage
Baseboard Management Controller Utilities User's Guide
" for the complete list.
If you get the message "already installed" when trying to install the ipmitool Linux .rpm file, use the --force option.
For example, rpm -Uvh --force <rpm filename>
Global Support
For information on documentation support, visit
support.dell.com/manuals.
On the
Manuals
page, click
Software
‐>
Systems Management.
Click on the specific product on the right‐side to access the documents.
Information in this document is subject to change without notice.
(C) 2011 Dell Inc. All rights reserved.
Reproduction of these materials in any manner whatsoever without the written permission of Dell Inc. is strictly forbidden.
Trademarks used in this text: Dell™, OpenManage™, PowerVault™ and PowerEdge™ are trademarks of Dell Inc. Microsoft®,
Windows®, and Windows Server® are either trademarks or registered trademarks of Microsoft Corporation in the United
States and/or other countries. Red Hat Enterprise Linux® is a registered trademark of Red Hat, Inc. in the United States and
other countries. Novell®and Netware® are registered trademarks of Novell,Inc. in the United States and
other countries.
Server Administrator uses the OverLIB JavaScript library. This library can be obtained from
http://www.bosrup.com/web/overlib/.
Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and
names or their products. Dell Inc. disclaims any proprietary interest in trademarks and trade names other than its own.
Year Month (2012 – 3) Rev. A00