Dell Powerconnect 7048P Owners Manual User’s Configuration Guide

Dell-Powerconnect-7048R-Owners-Manual-114491 dell-powerconnect-7048r-owners-manual-114491

Dell-Powerconnect-7048-Owners-Manual-114483 dell-powerconnect-7048-owners-manual-114483

Dell-Powerconnect-7024P-Owners-Manual-114479 dell-powerconnect-7024p-owners-manual-114479

Dell-Powerconnect-7024F-Owners-Manual-114475 dell-powerconnect-7024f-owners-manual-114475

Dell-Powerconnect-7024-Owners-Manual-114471 dell-powerconnect-7024-owners-manual-114471

2014-11-13

: Dell Dell-Powerconnect-7048P-Owners-Manual-114487 dell-powerconnect-7048p-owners-manual-114487 dell pdf

Open the PDF directly: View PDF PDF.
Page Count: 1270

DownloadDell Dell-Powerconnect-7048P-Owners-Manual- User’s Configuration Guide  Dell-powerconnect-7048p-owners-manual
Open PDF In BrowserView PDF
Dell PowerConnect
7000 Series Switch

User’s Configuration
Guide

Regulatory Models: PC7024, PC7024P,
PC7024F, PC7048, PC7048P, PC7048R, and
PC7048R-RA

Notes and Cautions
NOTE: A NOTE indicates important information that helps you make better use of
your computer.
CAUTION: A CAUTION indicates potential damage to hardware or loss of data if
instructions are not followed.

____________
Information in this publication is subject to change without notice.
© 2013 Dell Inc. All rights reserved.
Reproduction of these materials in any manner whatsoever without the written permission of Dell Inc.
is strictly forbidden.
Trademarks used in this text: Dell™, the DELL logo, EqualLogic™, PowerConnect™, and
OpenManage™ are trademarks of Dell Inc. Microsoft®, Windows®, Windows Server®, MS-DOS®,
and Windows Vista® are either trademarks or registered trademarks of Microsoft Corporation in the
United States and/or other countries. sFlow® is a registered trademark of InMon Corporation. Cisco®
is a registered trademark of Cisco Systems. Mozilla® and Firefox® are registered trademarks of the
Mozilla Foundation.
Other trademarks and trade names may be used in this publication to refer to either the entities claiming
the marks and names or their products. Dell Inc. disclaims any proprietary interest in trademarks and
trade names other than its own.
Regulatory Models: PC7024, PC7024P, PC7024F, PC7048, PC7048P, PC7048R, and PC7048R-RA

January 2013

Rev. A05

Contents
1

Introduction .

. . . . . . . . . . . . . . . . . . . . . .

About This Document
Audience .

. . . . . . . . . . . . . . . . . .

49

. . . . . . . . . . . . . . . . . . . . . . . .

49

Document Conventions

. . . . . . . . . . . . . . . . .

Additional Documentation .

2

Switch Features

50

. . . . . . . . . . . . . . . . . . .

51

. . . . . . . . . . . . .

52

. . . . . . . . . .

52

. . . . . . . . . . . .

52

. . . . . . . . . . . . . . . . . . .

53

Multiple Management Options .
System Time Management .
Log Messages

50

. . . . . . . . . . . . . . .

System Management Features

Integrated DHCP Server . . . . . . . . . . .
Management of Basic Network Information .
IPv6 Management Features
File Management .

. . .

54
54

. . .

. . . . . . . . . . . .

54

. . . . . . . . . . . . . . .

54

. . . . . . . . . . . . . . . . .

55

Dual Software Images

Switch Database Management Templates .

. . . .

55

. . . . . .

55

. . . . . . . . . . . . . . . . . . . . . . . .

56

Automatic Installation of Firmware and
Configuration . . . . . . . . . . . . . .
sFlow

49

SNMP Alarms and Trap Logs .

. . . . . . . . . . .

56

. . . . . . . . . . . .

56

. . . . . . . . . . . . . . . . . . . .

57

Remote Monitoring (RMON)
Stacking Features

56

. . . . . . . .

CDP Interoperability through ISDP .

High Port Count .

. . . . . . . . . . . . . . . . . .

Contents

57

3

Single IP Management

. . . . . . . . . . . . . . .

Automatic Firmware Update for New Stack
Members . . . . . . . . . . . . . . . . . .

. . . .

Stacking Compatibility with the PowerConnect
M6348 . . . . . . . . . . . . . . . . . . . . . .
Master Failover with Transparent Transition .
Nonstop Forwarding on the Stack . . . . . .

. .

57
58
58

. . .
. .

58

. . . . . . . . . . . . . . . . . . . .

58

Configurable Access and Authentication
Profiles . . . . . . . . . . . . . . . . . .

. . . . .
. . . .

59
59

TACACS+ Client .

. . . . . . . . . . . . . . . . . .

59

RADIUS Support

. . . . . . . . . . . . . . . . . .

59

. . . . . . . . . . . . . . . . . . . . . .

60

Strong Password Enforcement .

SSH/SSL .

Inbound Telnet Control

. . . . . . . . . . . . . . .

60

. . . . . . . . . . . . . . . . . .

60

Port Protection

. . . . . . . . . . . . . . . . . . .

60

Captive Portal .

. . . . . . . . . . . . . . . . . . .

61

Denial of Service

Dot1x Authentication (IEEE 802.1X) .

. . . . . . . .

61

MAC-Based 802.1X Authentication .

. . . . . . . .

61

. . . . . . . . . . . . . . . .

62

Dot1x Monitor Mode

MAC-Based Port Security

. . . . . . . . . . . . .

62

Access Control Lists (ACL)

. . . . . . . . . . . . .

62

. . . . . . . . . . . . . . . . .

63

Time-Based ACLs .

. . . . . . . . . . . . . .

63

. . . . . . . . . . . . . . . . . .

63

IP Source Guard (IPSG) .
DHCP Snooping .

Dynamic ARP Inspection

. . . . . . . . . . . . . .

64

. . . . . . . . . . . . . . .

65

. . . . . . . . . . . . . . . .

65

Green Technology Features
Energy Detect Mode

63

. . . . . . .

Protected Ports (Private VLAN Edge).

Energy Efficient Ethernet
Contents

58

. . . . . . . . . .

Password-Protected Management Access

4

57

. . .

Hot Add/Delete and Firmware Synchronization
Security Features

57

. . . . . . . . . . . . . .

65

Power Utilization Reporting

. . . . . . . . . . . .

Power over Ethernet (PoE) Plus Features .

. . . . . . .
. .

66
66

. . . . . . . . . . . . . . . . . . .

66

PoE Plus Support

. . . . . . . .

66

. . . . . . . . .

66

. . . . . . . . . . . . . .

67

Flow Control Support (IEEE 802.3x) .
Head of Line Blocking Prevention
Jumbo Frames Support .

Auto-MDI/MDIX Support .

. . . . . . . . . . . . .

67

. . . . . . . . . . . . . .

67

. . . . . . . . . . . . . . . . . .

68

Back Pressure Support .
Auto Negotiation

. . . . . . . . . . . . .

68

. . . . . . . . . . . . . . . . . . .

68

Broadcast Storm Control .

. . . . .

69

. . . . . . .

69

Static and Dynamic MAC Address Tables
Link Layer Discovery Protocol (LLDP)

Link Layer Discovery Protocol (LLDP) for
Media Endpoint Devices . . . . . . . . .
Connectivity Fault Management
(IEEE 802.1ag) . . . . . . . . . .
DHCP Layer 2 Relay .

. . . . .

69

. . . . . . . . . .

69

. . . . . . . . . . .

70

. . . . . . . . . . . . . . . .

70

switchCisco Protocol Filtering

Virtual Local Area Network Supported Features .
VLAN Support .

67

. . . . . . .

VLAN-Aware MAC-based Switching .

Port Mirroring .

66

. . . . . . . . . . . . . . . . . .

Power Over Ethernet (PoE) Plus Configuration

Switching Features

65

. . .

70

. . . . . . . . . . . . . . . . . . .

70

Port-Based VLANs

. . . . . . . . . . . . . . . . .

IP Subnet-based VLAN .
MAC-based VLAN

70

. . . . . . . . . . . . . .

71

. . . . . . . . . . . . . . . . .

71

IEEE 802.1v Protocol-Based VLANs
GARP and GVRP Support .

. . . . . . . .

71

. . . . . . . . . . . . .

71

Voice VLAN .

. . . . . . . . . . . . . . . . . . . .

71

Guest VLAN .

. . . . . . . . . . . . . . . . . . . .

72

Double VLANs

. . . . . . . . . . . . . . . . . . .

Contents

72

5

Spanning Tree Protocol Features

. . . . . . . . . . . .
. . . . . . . . . . .

73

. . . . . . . . . . . .

73

. . . . . . . . . . . . . . . .

73

Spanning Tree Protocol (STP)
Spanning Tree Port Settings
Rapid Spanning Tree

Multiple Spanning Tree .

. . . . . . . . . . . . . .

Bridge Protocol Data Unit (BPDU) Guard .
BPDU Filtering . . . . . . . . . . . . . .

74
74

. . . . . . . . . . . . . . .

74

. . . . . . . . . . . . . . . . . .

74
74

. . . . . . . . . . . . . . . . . . . .

76

Address Resolution Protocol (ARP) Table
Management . . . . . . . . . . . . . . .
VLAN Routing .

. . . . .

76

. . . . . . . . . . . . . . . . . . .

76

IP Configuration .

. . . . . . . . . . . . . . . . . .

BOOTP/DHCP Relay Agent
IP Helper and UDP Relay .

. . . . . . . . . .

76
77
77

. . . . . . . . . . . . .

Routing Information Protocol .

. . . . . . . . . . .

77

. . . . . . . . . . . . . . . . . .

77

. . . . . . . . . . . . . . . . . . . .

77

Router Discovery

Virtual Router Redundancy Protocol (VRRP) .

. . .

78

. . . . . . . . . .

78

. . . . . . . . . . . . . . . . . .

78

Tunnel and Loopback Interfaces
IPv6 Routing Features

IPv6 Configuration
IPv6 Routes

. . . . . . . . . . . . . . . . .

78

. . . . . . . . . . . . . . . . . . . . .

79

OSPFv3

. . . . . . . . . . . . . . . . . . . . . . .

79

DHCPv6

. . . . . . . . . . . . . . . . . . . . . . .

79

Quality of Service (QoS) Features

. . . . . . . . . . . .

Class Of Service (CoS)
Contents

80

. . . . . . . . .

80

. . . . . . . . . . . . . . .

80

Differentiated Services (DiffServ)

6

76

. . . . . . . . . . . . .

Open Shortest Path First (OSPF)

Routing Table

. . . . .

. . . . . .

Link Aggregate Control Protocol (LACP)
Routing Features .

73

. . . . .

Link Aggregation Features .
Link Aggregation

73

Auto Voice over IP (VoIP) .

. . . . . . . . . . . . .

Internet Small Computer System Interface
(iSCSI) Optimization . . . . . . . . . . . . .
Layer 2 Multicast Features

. . . .

81

. . . . . . . . . . . . . . .

81

. . . . . . . . . . . . . .

81

. . . . . . . . . . . . . . . . . .

81

MAC Multicast Support.
IGMP Snooping .

. . . . . . . . . . . . . .

82

. . . . . . . . . . . . . . . . . . .

82

IGMP Snooping Querier
MLD Snooping

Multicast VLAN Registration .
Layer 3 Multicast Features

. . . . . . . . . . .

82

. . . . . . . . . . . . . . .

83

. . .

83

. . . . . .

83

. . . . . . . . . . . . . . . . . . . .

83

Distance Vector Multicast Routing Protocol .
Internet Group Management Protocol .
IGMP Proxy .

Protocol Independent Multicast—Dense
Mode . . . . . . . . . . . . . . . . . . .

. . . . .

83

Protocol Independent Multicast—Sparse
Mode . . . . . . . . . . . . . . . . . . . .

. . . .

84

Protocol Independent Multicast—Source
Specific Multicast . . . . . . . . . . . . .

. . . .

84

Protocol Independent Multicast IPv6 Support .

. .

84

. . . . . . . . . .

84

. . . . . . . . . . . . . . . .

85

MLD/MLDv2 (RFC2710/RFC3810)

3

80

Hardware Overview .

PowerConnect 7000 Series Front Panel .

. . . . . . . .

85

Switch Ports

. . . . . . . . . . . . . . . . . . . .

88

Console Port

. . . . . . . . . . . . . . . . . . . .

89

. . . . . . . . . .

89

. . . . . . . . . . . . . . . . . . . . . .

89

Out-of-Band Management Port
USB Port

Reset Button . . . . .
Port and System LEDs

. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .

Stack Master LED and Stack Number Display .

. .

Contents

90
90
90

7

PowerConnect 7000 Series Back Panel .

. . . . . . . .
. . . . . . .

92

. . . . . . . . . . . . . . . . . .

93

Expansion Slots for Plug-in Modules .
Power Supplies .

Ventilation System

. . . . . . . . . . . . . . . . .

94

. . . . . . . . . . . . . . . . . . . .

94

. . . . . . . . . . . . . . . . . . . . .

95

. . . . . . . . . . . . . . . . . . . . . .

95

Locator LED .
LED Definitions .
Port LEDs

Module LEDs
System LEDs
Switch Addresses

4

. . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .

Using Dell OpenManage Switch
Administrator . . . . . . . . . . . . . .

. . . . . .

About Dell OpenManage Switch Administrator.
Starting the Application

Defining Fields .

103

. . . . . . . . . . . . . . . .

104

. . . . . . . . . . . . .

105

. . . . . . . . . . . . . . . . . . . .

107

. . . . . . . . . . .

Using the Device View Port Features .

. . . . . .

Using the Device View Switch Locator
Feature . . . . . . . . . . . . . . . . .

. . . . .

Using the Command-Line Interface .

108
108

109

. . . . . . . .

109

. . . . . . . . . . . . . . .

109

. . . . . . . . . . . . . . . .

110

Console Connection .
Telnet Connection .

108

. . .

Accessing the Switch Through the CLI

Contents

100

103

Understanding the Device View .

8

97
99

. . .

Understanding the Interface .

5

90

Understanding Command Modes
Entering CLI Commands

. . . . . . . . . . . .

111

. . . . . . . . . . . . . . . . .

113

. . . . . . .

113

. . . . . . . . . . . .

114

Using the Question Mark to Get Help
Using Command Completion

Entering Abbreviated Commands
Negating Commands

. . . . . . . . .

114

. . . . . . . . . . . . . . . .

114

Understanding Error Messages

6

Default Settings .

7

Setting the IP Address and Other
Basic Network Information . . . . .

. . . . .

IP Address and Network Information Overview
What Is the Basic Network Information?

. . . .

121
121
122

. . . . . . . .

123

. . . . . .

123

. . . . . . . . . . . . . .

125

Configuring Basic Network Information (Web) .

. . . .

126

. . . . . . . . . . . . . . .

126

IP Interface Configuration (Default VLAN IP
Address) . . . . . . . . . . . . . . . . . . .

. . .

127

. . . .

128

. . . . . . . . . . . . . . .

130
131
132

Route Entry Configuration (Switch Default
Gateway) . . . . . . . . . . . . . . . . . .
Domain Name Server .
Default Domain Name
Host Name Mapping .

121

. . .

What Is Out-of-Band Management and
In-Band Management? . . . . . . . . .

Out-of-Band Interface

117

. . . . .

Why Is Basic Network Information Needed?
How Is Basic Network Information
Configured? . . . . . . . . . . . . .

115

. . .

. . . . . . . . . . . . . . . . . .

Default Network Information

115

. . . . . . . . . .

Recalling Commands from the History Buffer

. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .

Contents

9

Dynamic Host Name Mapping

. . . . . . . . . .

Configuring Basic Network Information (CLI) .

. . . .

Enabling the DHCP Client on the OOB Port .

. . .

. . . . . . . . . . . . .

135

Configuring and Viewing Additional Network
Information . . . . . . . . . . . . . . . . . .

.

136

.

136

. .

137

Basic Network Information Configuration Example

.

138

. . . . . . . . . . .

141

. . . . . . . . . . . . . . . . . .

141

Managing a Switch Stack
Stacking Overview .

PowerConnect 7000 Series and M6348
Stacking Compatibility . . . . . . . . .

. . . . .

143

. . . . . . .

143

. . . . . . . . . .

145

How is the Stack Master Selected?
Adding a Switch to the Stack .

Removing a Switch from the Stack .

. . . . . . .

What is Stacking Standby? .

146

. . . . . . . . . . .

147

What is Nonstop Forwarding?

. . . . . . . . . .

Switch Stack MAC Addressing and Stack
Design Considerations . . . . . . . . . .

. . . .

150
150

. . . . . . . . . . . .

151

. . . . . . . . . . . . . . .

151

Why is Stacking Needed?

Managing and Monitoring the Stack (Web) .

. . . . .

152

. . . . . . . . . . . . . . . .

152

. . . . . . . . . . . . . . . . .

154

Unit Configuration .
Stack Summary .
Contents

147

. . . . . .

NSF Network Design Considerations .

Default Stacking Values .

146

. .

How is the Firmware Updated on the Stack? .

10

134
134

Configuring Static Network Information on the
OOB Port . . . . . . . . . . . . . . . . . . . .
Configuring Static Network Information on the
Default VLAN . . . . . . . . . . . . . . . . . .

8

134

.

Enabling the DHCP Client on the Default VLAN
Managing DHCP Leases

133

Stack Firmware Synchronization .

. . . . . . . . .

155

Supported Switches

. . . . . . . . . . . . . . . .

156

Stack Port Summary

. . . . . . . . . . . . . . . .

157

Stack Port Counters

. . . . . . . . . . . . . . . .

158

Stack Port Diagnostics .
NSF Summary .

. . . . . . . . . . . . . .

158

. . . . . . . . . . . . . . . . . . .

159

. . . . . . . . . . . . . . .

160

. . . . . . . . . . . . . . . .

161

Checkpoint Statistics .
Managing the Stack (CLI)

Configuring Stack Member, Stack Port, and
NSF Settings . . . . . . . . . . . . . . . . .

. . .

161

. . . . .

163

. . . . . . . . . .

163

. . . . . . . . . . . . . . . . . . .

164

Viewing and Clearing Stacking and NSF
Information . . . . . . . . . . . . . . . .
Stacking and NSF Usage Scenarios.
Basic Failover .

Preconfiguring a Stack Member .

. . . . . .

168
169
170
171

. . . . . . . . . . . . . .

173

NSF in the Data Center . . . . . . . . .
NSF and VoIP . . . . . . . . . . . . . .
NSF and DHCP Snooping . . . . . . . .
NSF and the Storage Access Network .
NSF and Routed Access

9

Configuring Authentication,
Authorization, and Accounting
AAA Overview
Methods

. . . . . .
. . . . . .
. . . . . .

. . . . . . .

175

. . . . . . . . . . . . . . . . . . . . . .

175

. . . . . . . . . . . . . . . . . . . . . .

176

Access Lines

. . . . . . . . . . . . . . . . . . . .

177

. . . . . . . . . . . . . . . . . . . . .

177

. . . . . . . . . . . . . . . . . . . . . .

178

Authentication .
Authorization .

166

. . . . . . . . .

Exec Authorization Capabilities

. . . . . . . . . .

Contents

179

11

Accounting .

. . . . . . . . . . . . . . . . . . . . . .

Authentication Examples

. . . . . . . . . . . . . . .

Local Authentication Example

. . . . . . . . . .

181

. . . . . . . .

182

RADIUS Authentication Example .

. . . . . . . .

184

. . . . . . . . . . . . . . . .

185

Local Authorization Example—Direct Login
to Privileged EXEC Mode . . . . . . . . . .

. . .

185

TACACS+ Authorization Example—Direct Login
to Privileged EXEC Mode . . . . . . . . . . . . .

185

TACACS+ Authorization Example—
Administrative Profiles . . . . . . .

186

. . . . . . .

TACACS+ Authorization Example—Custom
Administrative Profile . . . . . . . . . . . .
TACACS+ Authorization Example—
Per-command Authorization . . . .

. . .

187

. . . . . . .

188

RADIUS Authorization Example—Direct Login
to Privileged EXEC Mode . . . . . . . . . . . .
RADIUS Authorization Example—
Administrative Profiles . . . . . .

.

189

. . . . . . . .

189

Using RADIUS Servers to Control Management
Access . . . . . . . . . . . . . . . . . . . . . .
How Does RADIUS Control Management
Access? . . . . . . . . . . . . . . . . . .

Contents

181

TACACS+ Authentication Example

Authorization Examples

12

180

. . .

190

. . . .

190

Which RADIUS Attributes Does the Switch
Support?. . . . . . . . . . . . . . . . . . .

. . .

192

How Are RADIUS Attributes Processed on
the Switch? . . . . . . . . . . . . . . . . .

. . .

194

Using TACACS+ Servers to Control Management
Access . . . . . . . . . . . . . . . . . . . . . . .

. .

195

Which TACACS+ Attributes Does the Switch
Support?. . . . . . . . . . . . . . . . . . . .

. .

196

Default Configurations .
Method Lists

. . . . . . . . . . . . . . . . .

197

. . . . . . . . . . . . . . . . . . . .

197

Access Lines (AAA)

Administrative Profiles

. . . . . . . . . . . . .

198

. . . . . . . . . . . . . . .

198

10 Monitoring and Logging System
Information . . . . . . . . . . . . . . . .
System Monitoring Overview

. . . . . .

Where Are Log Messages Sent? .

201

. . . . .

201

. . . . . . .

202

. . . . . . . . .

202

Why Is System Information Needed?

. . .

203

. . .

203

. . . . . . . .

204

What Are the Severity Levels? . . . . . . . .
What Are the System Startup and Operation
Logs? . . . . . . . . . . . . . . . . . . . . .
What Is the Log Message Format? .

What Factors Should Be Considered When
Configuring Logging? . . . . . . . . . . . .

. . . .

205

. . . . . . . . . . . . . . . . . .

205

Monitoring System Information and Configuring
Logging (Web) . . . . . . . . . . . . . . . . . . .
Device Information

. . .

207

. . . . . . . . . . . . . . . . .

207

. . . . .

209
210
211
212
213

. . . . . . . . . . . . . . . .

215

. . . . . . . . . . . . . . . . . . . . . .

216

System Health . . . . . . . . . . . . . .
System Resources . . . . . . . . . . . .
Unit Power Usage History . . . . . . . .
Integrated Cable Test for Copper Cables .
Optical Transceiver Diagnostics . . . . .
Log Global Settings .
RAM Log

201

. . . . . . . . . . . . . .

What System Information Is Monitored? .

Default Log Settings .

197

. . . . . . . . . . . . . . . .

Access Lines (Non-AAA) .

Log File . . . . . .
Remote Log Server

. . . . .
. . . . .
. . . . .
. . . . .

. . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . .

Email Alert Global Configuration

. . . . . . . . . .

Contents

217
217
220

13

Email Alert Mail Server Configuration

. . . . . .

221

Email Alert Subject Configuration . .
Email Alert To Address Configuration.

. . . . . .
. . . . . .

223
224

. . . . . . . . . . . . . . .

225

Email Alert Statistics

Monitoring System Information and Configuring
Logging (CLI) . . . . . . . . . . . . . . . . . . .

. . .

226

Viewing System Information and Enabling
the Locator LED . . . . . . . . . . . . . . .

. . .

226

. . . . . . . . . . .

226

. . . . . . . . . . . .

227

Running Cable Diagnostics .
Configuring Local Logging

. . .

229
230
231

. . . . . . . . . . .

233

Configuring Remote Logging . . . . . . . .
Configuring Mail Server Settings . . . . . .
Configuring Email Alerts for Log Messages
Logging Configuration Examples

. . . . .

233

. . . . . . . . . . . .

234

Configuring Local and Remote Logging
Configuring Email Alerting

11 Managing General System Settings
System Settings Overview .

. . .
. . .

. . .

239

. . . . . . . . . . . . . .

239

Why Does System Information Need to
Be Configured? . . . . . . . . . . . . .
What Are SDM Templates? .

. . . . .

240

. . . . . . . . . . .

241

. . . . . . . .

242

. . . . . . . . . . . . .

242

Why is the System Time Needed?
How Does SNTP Work? .

What Configuration Is Required for Plug-In
Modules? . . . . . . . . . . . . . . . . . .

. . .

What Are the Key PoE Plus Features for the
PC7024P and PC7048P? . . . . . . . . . . . .
Default General System Information

. .

243

. . . . . . . . .

245

Configuring General System Settings (Web)
System Information .

14

Contents

243

. . . . .

246

. . . . . . . . . . . . . . .

246

CLI Banner . . . . . . . . .
SDM Template Preference .
Clock . . . . . . . . . . . .
SNTP Global Settings . . . .
SNTP Authentication . . . .
SNTP Server . . . . . . . .
Summer Time Configuration
Time Zone Configuration . .

249
250
251
252
253
255

. . . . . . . . . . . .
. . . . . . . . . . . .
. . . . . . . . . . . .
. . . . . . . . . . . .
. . . . . . . . . . . .
. . . . . . . . . . . .

259
260

. . . . . . . . . . . .
. . . . . . . . . . . .

Card Configuration . . . . . . . . . . . . . .
Slot Summary . . . . . . . . . . . . . . . . .
Supported Cards . . . . . . . . . . . . . . .
Power Over Ethernet Global Configuration
(7024P/7048P Only) . . . . . . . . . . . . . .
Power Over Ethernet Interface Configuration
(7024P/7048P Only) . . . . . . . . . . . . . .
Configuring System Settings (CLI) .

. . .

261
262
263

. . .

264

. . .

265

. . . . . . . . . . .

267

Configuring System Information

. . .
. . .

267

. . . . . . . . . .

Configuring the Banner . . . . . . . . . .
Managing the SDM Template . . . . . .
Configuring SNTP Authentication and an
SNTP Server . . . . . . . . . . . . . . .

. . . . .

268
269

. . . . .

269

. . . . .

Setting the System Time and Date Manually .
Configuring the Expansion Slots . . . . . . .

. . .
. . .

271
272

Configuring PoE Settings (7024P/7048P Only)

. . .

273

General System Settings Configuration Examples

. . .

276

. . .

276

. . . . . . . . . .

279
281

Configuring System and Banner Information
Configuring SNTP . . . . . . . .
Configuring the Time Manually .

12 Configuring SNMP .
SNMP Overview .

. . . . . . . . . .

. . . . . . . . . . . . . . . .

283

. . . . . . . . . . . . . . . . . . . .

What Is SNMP? .

. . . . . . . . . . . . . . . . . .

Contents

283
283

15

What Are SNMP Traps?

. . . . . . . . . . . . .

284

Why Is SNMP Needed? .

. . . . . . . . . . . . .

285

. . . . . . . . . . . . . . . . .

285

Default SNMP Values

Configuring SNMP (Web)

. . . . . . . . . . . . . . .

SNMP Global Parameters

. . . . . . . . . . . .

. . . . . .

. . . . . . . . . . . . . . . . . . . .

301

. . . . . .
. . . . . .
. . . . . .
. . . . . .
. . . . . .

OSPFv2 Trap Flags

. . . . . . . . . . . . . . . .

302

OSPFv3 Trap Flags

. . . . . . . . . . . . . . . .

303

. . . . . . . . . . . . . . . . . . . . .

304

Trap Log .

Configuring SNMP (CLI)

. . . . . . . . . . . . . . . .

Configuring the SNMPv3 Engine ID.

. . . . . . .

Configuring Communities .

. . . . . . . . . . . .

309

. . .

311

. . . . . . . . . . . .

314

. . . . . . .

314

. . . . . . . . . . . . . . .

315

Configuring SNMPv1 and SNMPv2 .
Configuring SNMPv3

13 Managing Images and Files .

. . . . . . . . .

Image and File Management Overview
What Files Can Be Managed?

319

. . . . . . . .

319

. . . . . . . . . .

319

Why Is File Management Needed? .

Contents

305
306

Configuring SNMP Notifications (Traps and
Informs) . . . . . . . . . . . . . . . . . . .
SNMP Configuration Examples

305

. .

Configuring SNMP Views, Groups, and Users

16

287
288
290
292
295
297
298

SNMP View Settings . . . . . . . . .
Access Control Group . . . . . . . .
SNMPv3 User Security Model (USM)
Communities . . . . . . . . . . . . .
Notification Filter . . . . . . . . . . .
Notification Recipients . . . . . . . .
Trap Flags .

287

. . . . . . .

321

What Methods Are Supported for File
Management? . . . . . . . . . . . .

323

. . . . . . .

What Factors Should Be Considered When
Managing Files? . . . . . . . . . . . . . .

. . . .

323

How Is the Running Configuration Saved? .

. . . .

325

. . . . . . . . . . .

326

. . . . . . . . . . . . . . . . . . . . .

326

Managing Images and Files (Web)
File System

Active Images .
USB Flash Drive.
File Download . .
File Upload . . .
Copy Files . . . .

327
328
329
331
333

. . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . .

Managing Images and Files (CLI)

Downloading and Activating a New Image
(TFTP) . . . . . . . . . . . . . . . . . . . .

. . . .

334

. . . . . .

. . . . . .

335
336
336

. . . . . .

337

. . . . . .

338

. . . . . . . . . . . . . .

338

Managing Files in Internal Flash . . . .
Managing Files on a USB Flash Device
Uploading a Configuration File (SCP) . .
Managing Configuration Scripts (SFTP)
File and Image Management Configuration
Examples . . . . . . . . . . . . . . . . . . .
Upgrading the Firmware

Managing Configuration Scripts

. . . . . .

341

. . . . . . . . . .

Managing Files by Using the USB Flash Drive .

14 Automatically Updating the Image
and Configuration . . . . . . . . . . . . .
Auto Configuration Overview

334

. . . . . . . . . . . .

343

. .

. . . .

345

. . . . . . . . . . . . . .

What Is USB Auto Configuration?

. . . . . . . . .

What Files Does USB Auto Configuration
Use? . . . . . . . . . . . . . . . . . . . .

. . . . .

Contents

345
346
346

17

How Does USB Auto Configuration Use the
Files on the USB Device? . . . . . . . . . .
What Is the Setup File Format? . . . . . . .

. . .

348
349

What Is the DHCP Auto Configuration
Process? . . . . . . . . . . . . . . .

. . . . . .

350

Monitoring and Completing the DHCP
Auto Configuration Process . . . . .

. . . . . .

355

What Are the Dependencies for DHCP
Auto Configuration? . . . . . . . . . . .
Default Auto Configuration Values

. . . . .

356

. . . . . . . . . .

357

Managing Auto Configuration (Web)
Auto-Install Configuration

. . .

. . . . . . . . .

358

. . . . . . . . . . . .

358

Managing Auto Configuration (CLI)

. . . . . . . . . .

359

Managing Auto Configuration

. . . . . . . . . .

359

. . . . . . . . . . . . .

360

Auto Configuration Example .

Enabling USB Auto Configuration and Auto
Image Download . . . . . . . . . . . . . .

. . .

Enabling DHCP Auto Configuration and Auto
Image Download . . . . . . . . . . . . . . .

. .

362

. . . . . . . . . . .

363

. . . . . . . . . . . . .

363

15 Monitoring Switch Traffic
Traffic Monitoring Overview .

. . . . . . . . . . .

363

. . . . . . . . . . . . . . . . .

366

What is sFlow Technology? .
What is RMON? .

What is Port Mirroring? .

. . . . . . . . . . . . .

Why is Traffic Monitoring Needed?

368

. . . . . . . . . .

368

. . . . . . . . . . .

369

. . . . . . . . . . . . . .

369

Monitoring Switch Traffic (Web)
sFlow Agent Summary

Contents

367

. . . . . . .

Default Traffic Monitoring Values .

18

360

sFlow Receiver Configuration . .
sFlow Sampler Configuration . . .
sFlow Poll Configuration . . . . .
Interface Statistics . . . . . . . .
Etherlike Statistics . . . . . . . .
GVRP Statistics . . . . . . . . . .
EAP Statistics . . . . . . . . . . .
Utilization Summary . . . . . . .
Counter Summary. . . . . . . . .
Switchport Statistics . . . . . . .
RMON Statistics . . . . . . . . .
RMON History Control Statistics .
RMON History Table
RMON Event Control
RMON Event Log . .
RMON Alarms . . .
Port Statistics . . . .
LAG Statistics . . . .
Port Mirroring . . . .

370
371
372
373
374
375
376
377
378
379
380
381

. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .

383
384
386
387
389
390
391

. . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . .

Monitoring Switch Traffic (CLI)

. . . . . . . . . . . . .

393

. . . . . . . . . . . . . . . . .

393

Configuring RMON

. . . . . . . . . . . . . . . . .

395

Viewing Statistics .

. . . . . . . . . . . . . . . . .

397

Configuring sFlow.

Configuring Port Mirroring

398

. . . . . . . . . . . . .

Traffic Monitoring Configuration Examples .

. . . . . .

399

Configuring sFlow.

. . . . . . . . . . . . . . . . .

399

Configuring RMON

. . . . . . . . . . . . . . . . .

401

16 Configuring iSCSI Optimization .
iSCSI Optimization Overview

. . . . . .

403

. . . . . . . . . . . . . .

What Does iSCSI Optimization Do?.

. . . . . . . .

Contents

403
404

19

How Does the Switch Detect iSCSI Traffic
Flows? . . . . . . . . . . . . . . . . . . . .

. . .

404

How Is Quality of Service Applied to iSCSI
Traffic Flows? . . . . . . . . . . . . . . . .

. . .

404

. . . .

405

How Does iSCSI Optimization Use ACLs?

What Information Does the Switch Track in
iSCSI Traffic Flows? . . . . . . . . . . . . .

. . .

405

. . .

407

. . .

407

. . .

408

. . . . . . . . . .

409

How Does iSCSI Optimization Interact With
Dell EqualLogic Arrays?. . . . . . . . . . .
What Occurs When iSCSI Optimization Is
Enabled or Disabled? . . . . . . . . . . . .
How Does iSCSI Optimization Interact with
Dell Compellent Arrays? . . . . . . . . . .
Default iSCSI Optimization Values

Configuring iSCSI Optimization (Web).

. . . . . . . .

410

. . . . . . . . . . . .

410

. . . . . . . . . . . . .

411
412
413

iSCSI Global Configuration
iSCSI Targets Table . . .
iSCSI Sessions Table . .
iSCSI Sessions Detailed

. . . . . . . . . . . . .
. . . . . . . . . . . . .

Configuring iSCSI Optimization (CLI)

. . . . . . . . .

iSCSI Optimization Configuration Examples

. . . . .

Configuring iSCSI Optimization Between
Servers and a Disk Array . . . . . . . . .

416

. . . . . . . . . .

419

. . . . . . . . . . . . . . .

419

What Does Captive Portal Do?

. . . . . . . . . .

Is the Captive Portal Feature Dependent
on Any Other Feature? . . . . . . . . . .

. . . .

What Factors Should Be Considered When
Designing and Configuring a Captive Portal?.
How Does Captive Portal Work?

20

Contents

416

. . . .

17 Configuring Captive Portal
Captive Portal Overview .

414

419
420

. .

421

. . . . . . . . .

422

What Captive Portal Pages Can Be
Customized? . . . . . . . . . . . .

Default Captive Portal Behavior and Settings
Configuring the Captive Portal (Web) .

. . . . .

424

. . . . . . . . .

426

. . . . . . . .

426

. . . . . . . . . . . .

427
432

Captive Portal Global Configuration
Captive Portal Configuration
Local User . . . . . . . . .
User Group . . . . . . . . .
Interface Association . . . .
Captive Portal Global Status

. . . . . . . . . . . .

436
438
439

. . . . . . . . . . . .
. . . . . . . . . . . .
. . . . . . . . . . . .

Captive Portal Activation and Activity Status
Interface Activation Status . . . . . . . . . .

440
441

. . .
. . .

. . . . . . .

442
443
444
445
446

. . . . . . . . . . . .

447

Interface Capability Status . . . . . .
Client Summary . . . . . . . . . . . .
Client Detail . . . . . . . . . . . . . .
Captive Portal Interface Client Status
Captive Portal Client Status . . . . .
Configuring Captive Portal (CLI) .

423

. . . . . . . .

. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .

Configuring Global Captive Portal Settings.

. . . .

447

Creating and Configuring a Captive Portal .

. . . .

448

. . .

451
452

. . . . . . . . .

453

Configuring Captive Portal Groups and Users
Managing Captive Portal Clients . . . . . . .
Captive Portal Configuration Example

Configuration Overview. . . . . . .
Detailed Configuration Procedures

454
455

. . . . . . . .
. . . . . . . .

18 Configuring Port Characteristics
Port Overview

. . .

. . . . .

457

. . . . . . . . . . . . . . . . . . . . . .

What Physical Port Characteristics Can
Be Configured? . . . . . . . . . . . . . .

. . . . .

Contents

457
457

21

What is Link Dependency?

. . . . . . . . . . . .

What Interface Types are Supported? .
What is Interface Configuration Mode?

. . . . .

460
460

What Are the Green Ethernet Features?

. . . . .

462

. . . . . . . . . . . . . . . . . .

463

Default Port Values .

Configuring Port Characteristics (Web) .
Port Configuration.

. . . . . . .

464
464

Link Dependency Summary .

. . . . . . . . .

467

. . . . . . . . . . .

469

. . . . . . . .

470

. . . . . . . . . .

471

Port Green Ethernet Configuration
Port Green Ethernet Statistics

Port Green Ethernet LPI History

. . . . . . . . .

Configuring Port Characteristics (CLI) .
Configuring Port Settings .

475

. . . . . . . . . . . .

475

. . . . . . . . .

476

. . . . . . . . . . .

477

. . . . . . . . . . . . .

479

Configuring Green Features
Port Configuration Examples

Configuring Port Settings .

. . . . . . . . . . . .

479

. . . . .

480

. . . . . . . .

481

. . . . . . . . . . . . . . . . . . . . . . .

482

Configuring a Link Dependency Groups

19 Configuring Port and System
Security . . . . . . . . . . . . . . . . .
What is IEEE 802.1X?

. . . . . . . . . . . . . . .

What are the 802.1X Port States? .

. . . . . . . .

What is MAC-Based 802.1X Authentication? .

What is Monitor Mode? .

482
483

. .

484

. . . . . . .

485

. . . . . . . . . . . . .

487

What is the Role of 802.1X in VLAN
Assignment? . . . . . . . . . . . .

Contents

474

. . . . . . . .

Configuring Link Dependencies

IEEE 802.1X

. . . . .

. . . . . . . . . . . . . . . .

Link Dependency Configuration

22

458

How Does the Authentication Server Assign
DiffServ Filters? . . . . . . . . . . . . . . . .

. . .

489

What is the Internal Authentication Server? .

. . .

489

. . . . . . . . . . . . . . .

490

Default 802.1X Values .

Configuring IEEE 802.1X (Web)

. . . . . . . . . . .

491

Configuring IEEE 802.1X (CLI) .

. . . . . . . . . . .

498

Configuring Internal Authentication Server
Users . . . . . . . . . . . . . . . . . . . .
IEEE 802.1X Configuration Examples . . . .

. . . .

503
503

. . . . . . . . . . .

517

. . . . . . . . . . . . . . .

517

Port Security (Port-MAC Locking) .
Default 802.1X Values .

. . . . . . . . . .

520

. . . . . . . . . . . . . . . . . . . .

521

Configuring Port Security (CLI) .
Denial of Service

20 Configuring Access Control Lists
ACL Overview

. . . .

. . . . .

523

. . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .

524

. . . . . . . . . . . . . . . . .

525

What Are MAC ACLs?
What Are IP ACLs?

523

. . . . . . . .

525

. . . . . . . . .

525

. . . . . . . . . . . . . . . .

526

What Is the ACL Redirect Function?
What Is the ACL Mirror Function?
What Is ACL Logging

What Are Time-Based ACLs? .

. . . . . . . . . . .

What Are the ACL Limitations? .
How Are ACLs Configured? .

526

. . . . . . . . . .

527

. . . . . . . . . . . .

528

. . . . . . . . . .

528

Configuring ACLs (Web) .

. . . . . . . . . . . . . . . .

530

IP ACL Configuration

. . . . . . . . . . . . . . . .

530

Preventing False ACL Matches .

. . . . . . . . . . . . .

532

. . . . . . . . . . . . . .

534

IP ACL Rule Configuration
MAC ACL Configuration

MAC ACL Rule Configuration .
IPv6 ACL Configuration . . . .

. . . . . . . . . . .
. . . . . . . . . . .

Contents

536
537

23

IPv6 ACL Rule Configuration

. . . . . . . . . . .

ACL Binding Configuration . . .
Time Range Entry Configuration
Configuring ACLs (CLI) .

. . . . . . . . .

540
541

. . . . . . . . . . . . . . . .

543

. . . . . . . . .

Configuring an IPv4 ACL

. . . . . . . . . . . . .

543

Configuring a MAC ACL .

. . . . . . . . . . . . .

545

Configuring an IPv6 ACL

. . . . . . . . . . . . .

547

Configuring a Time Range.

. . . . . . . . . . . .

549

. . . . . . . . . . . . .

551

. . . . . . . . . . . . . .

551

ACL Configuration Examples.
Configuring an IP ACL .

Configuring a MAC ACL .

. . . . . . . . . . . . .

555
556

. . . . . . . . . . . . . . . .

561

. . . . . . . . . . . . . . . . . . . .

561

21 Configuring VLANs .
VLAN Overview

564

. . . . . . . . . . . . . . . . . .

565

. . . . . . . . . . . . . . . . . . . . . . .

566

VLAN Tagging .

Double-VLAN Tagging
Voice VLAN

. . . . . . . . . . . . . .

566

. . . . . . . . . . . . . . . . . . . .

568

Private VLANs .

. . . . . . . . . . . . . . . . . .

Additional VLAN Features
Default VLAN Behavior

570

. . . . . . . . . . . .

576

. . . . . . . . . . . . . . . .

577

Configuring VLANs (Web)

. . . . . . . . . . . . . . .

579

VLAN Membership

. . . . . . . . . . . . . . . .

579

VLAN Port Settings
VLAN LAG Settings

. . . . . . . . . . . . . . . .

584
585

. . . . . . . . . . . . . . . .

Bind MAC to VLAN . . .
Bind IP Subnet to VLAN .
Contents

. . . . .

. . . . . . . . . . . . . . . .

Switchport Modes
GVRP

553

. . . . .

Configuring a Time-Based ACL . . . . .
Configuring a Management Access List

24

538

. . . . . . . . . . . . .
. . . . . . . . . . . . .

587
588

GVRP Parameters.
Protocol Group . .

. . . . . . . . . . . . . . . . .

Adding a Protocol Group

593

. . . . . . . . . . . . . .

Double VLAN Global Configuration . .
Double VLAN Interface Configuration
Voice VLAN . . . . . . . . . . . . . .

. . . . . . .

595
596
598

. . . . . . . . . . . . . . . .

599

. . . . . . . . . . . . . . . . . .

599

Configuring VLANs (CLI) .
Creating a VLAN

590
592

. . . . . . . . . . . . . . . . .

Configuring a Port in Access Mode
Configuring a Port in Trunk Mode

. . . . . . .
. . . . . . .

. . . . . . . .

599

. . . . . . . . .

600

Configuring a Port in General Mode .
Configuring VLAN Settings for a LAG

. . . . . . .

Configuring Double VLAN Tagging . .
Configuring MAC-Based VLANs . . .
Configuring IP-Based VLANs . . . . .
Configuring a Protocol-Based VLAN .

. . . . . . .

Configuring GVRP .

603
604

. . . . . . .

. . . . . . .

606
607
608
608

. . . . . . . . . . . . . . . . .

610

. . . . . . .
. . . . . . .

Configuring Voice VLANs .

. . . . . . . . . . . . .

612

VLAN Configuration Examples

. . . . . . . . . . . . .

613

Configuring VLANs Using Dell OpenManage
Administrator . . . . . . . . . . . . . . . . .
Configure the VLANs and Ports on Switch 2 .

. . .

616
620

. . . . . . . . .

621

. . . . . . . . . . . . .

625

Configuring VLANs Using the CLI.
Configuring a Voice VLAN

22 Configuring the Spanning Tree
Protocol . . . . . . . . . . . . . . . . .
STP Overview

. . .

. . . . . . .

629

. . . . . . . . . . . . . . . . . . . . . .

What Are Classic STP, Multiple STP, and
Rapid STP? . . . . . . . . . . . . . . . .
How Does STP Work?

629

. . . . .

629

. . . . . . . . . . . . . . .

630

How Does MSTP Operate in the Network?

. . . .

Contents

631

25

MSTP with Multiple Forwarding Paths .
What are the Optional STP Features? .
Default STP Values .

. . . . .

635
636

. . . . . . . . . . . . . . . . . .

639

Configuring Spanning Tree (Web)

. . . . . . . . . . .

640

STP Global Settings .

. . . . . . . . . . . . . . .

640

STP Port Settings . .
STP LAG Settings . .
Rapid Spanning Tree

. . . . . . . . . . . . . . .

641
643
644

. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .

MSTP Settings . . . . .
MSTP Interface Settings

. . . . . . . . . . . . .
. . . . . . . . . . . . .

Configuring Spanning Tree (CLI) .

. . . . . . . . . . .

650
650

Configuring Optional STP Features .

. . . . . . .

651

Configuring STP Interface Settings .

. . . . . . .

652

Configuring MSTP Switch Settings . .
Configuring MSTP Interface Settings

. . . . . .

653
654

. . . . . . . . . . . . .

655

. . . . . . . . . . . . . . . . .

655

STP Configuration Examples.
Configuring STP .

Configuring MSTP.

. . . . . .

. . . . . . . . . . . . . . . .

23 Discovering Network Devices .

657

. . . . . . .

659

. . . . . . . . . . . . .

659

What Is ISDP? .

. . . . . . . . . . . . . . . . . .

659

What is LLDP? .

. . . . . . . . . . . . . . . . . .

659

Device Discovery Overview .

What is LLDP-MED?

. . . . . . . . . . . . . . .

Why are Device Discovery Protocols
Needed?. . . . . . . . . . . . . . . .

Contents

646
648

. . . . .

Configuring Global STP Bridge Settings

26

. . . . .

. . . . . .

660
660

Default IDSP and LLDP Values

Configuring ISDP and LLDP (Web).

. . . . . . . . . . .

663

. . . . . . . . . . . . .

663

. . . . . . . . . . . . . . . . .

664

ISDP Global Configuration
ISDP Cache Table .

661

. . . . . . . . . . . . .

ISDP Interface Configuration . . . . . .
ISDP Statistics . . . . . . . . . . . . .
LLDP Configuration . . . . . . . . . . .
LLDP Statistics . . . . . . . . . . . . .
LLDP Connections . . . . . . . . . . .
LLDP-MED Global Configuration . . . .
LLDP-MED Interface Configuration . .
LLDP-MED Local Device Information .
LLDP-MED Remote Device Information
Configuring ISDP and LLDP (CLI)

. . . . . .

665
667
668
670
671
673
674
676
677

. . . . . . . . . . . .

678

Configuring Global ISDP Settings

. . . . . .
. . . . . .
. . . . . .
. . . . . .
. . . . . .
. . . . . .
. . . . . .
. . . . . .

678

. . . . . . . . .

679
679

Enabling ISDP on a Port . . . . . . . .
Viewing and Clearing ISDP Information

. . . . . .

Configuring Global LLDP Settings . . .
Configuring Port-based LLDP Settings .

. . . . . .
. . . . . .

680
680

Viewing and Clearing LLDP Information

. . . . . .

681

. . . . . . . . . .

682
683

Configuring LLDP-MED Settings
Viewing LLDP-MED Information

. . . . . .

. . . . . . . . . .

Device Discovery Configuration Examples .

. . . . . .

683

Configuring ISDP

. . . . . . . . . . . . . . . . . .

683

Configuring LLDP

. . . . . . . . . . . . . . . . . .

684

24 Configuring Port-Based Traffic
Control . . . . . . . . . . . . . . . . . .
Port-Based Traffic Control Overview
What is Flow Control?

. . . . . . .

687

. . . . . . . . . .

687

. . . . . . . . . . . . . . .

688

What is Storm Control? .

. . . . . . . . . . . . . .

Contents

688

27

What are Protected Ports?

. . . . . . . . . . . .

What is Link Local Protocol Filtering?

. . . . . .

689

Default Port-Based Traffic Control Values

. . . . . .

690

Configuring Port-Based Traffic Control (Web)

. . . .

691

. . . . .

691

. . . . . . . . . .

692
694
696

Flow Control (Global Port Parameters) .
Storm Control . . . . . . . . .
Protected Port Configuration .
LLPF Configuration . . . . . .

. . . . . . . . . .
. . . . . . . . . .

Configuring Port-Based Traffic Control (CLI)

. . . . .
. . .

698
699

. . . . . . . . . . . . . . . . .

700

Configuring Protected Ports
Configuring LLPF

Port-Based Traffic Control Configuration
Example . . . . . . . . . . . . . . . . .

. . . . . . .

25 Configuring L2 Multicast Features
L2 Multicast Overview .

701

. . . .

703

. . . . . . . . . . . . . . . .

703

What Are the Multicast Bridging Features?

703

. . . . . . . . . .

704
705

. . . . . . . . . . . . .

707

What Is IGMP Snooping? .
What Is MLD Snooping?

. . .

. . . . . . . . . . . .

What Is L2 Multicast Traffic? .

What Is Multicast VLAN Registration? .

. . . . .
. . .

709
709

. . . . . . . . . . . .

711

What Are GARP and GMRP?
Snooping Switch Restrictions .

708

. . . . . . . . . . .

When Are L3 Multicast Features Required?

Partial IGMPv3 and MLDv2 Support

. . . . . . .

MAC Address-Based Multicast Group .

. . . . .

IGMP/MLD Snooping in a Multicast Router

Contents

698

. . . . . . . . . . .

Configuring Flow Control and Storm Control

28

689

. . .

711
711
711

Topologies Where the Multicast Source Is
Not Directly Connected to the Querier . . .

. . . .

712

Using Static Multicast MAC Configuration .

. . . .

712

. . . . . . . . . . . .

712

. . . . . . . . . . . . . .

713

IGMP Snooping and GMRP .
Default L2 Multicast Values .

Configuring L2 Multicast Features (Web) .

. . . . . . .

715

. . . . . . . . . . .

715

. . . . . . . . . . . . . .

716
719

Multicast Global Parameters .
Bridge Multicast Group .
MRouter Status . . . . .

. . . . . . . . . . . . . .

. . .

720
723
724
727
728
729
731

. . . . . . . . . . .

732

General IGMP Snooping . . . . . . . . . . .
Global Querier Configuration . . . . . . . . .
VLAN Querier . . . . . . . . . . . . . . . . .
VLAN Querier Status . . . . . . . . . . . . .
MFDB IGMP Snooping Table . . . . . . . . .
MLD Snooping General . . . . . . . . . . . .
MLD Snooping Global Querier Configuration
MLD Snooping VLAN Querier

MLD Snooping VLAN Querier Status .
MFDB MLD Snooping Table . . . . .
MVR Global Configuration . . . . . .
MVR Members . . . . . . . . . . . .
MVR Interface Configuration . . . . .
MVR Statistics . .
GARP Timers . . .
GMRP Parameters

. . .
. . .
. . .
. . .
. . .
. . .

. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .

. . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . .

MFDB GMRP Table .

. . . . . . . . . . . . . . . .

Configuring L2 Multicast Features (CLI) .
Configuring Layer 2 Multicasting .

734
735
736
737
738
741
742
744
746

. . . . . . . .

747

. . . . . . . . .

747

. . . . . .

748

Configuring IGMP Snooping Querier .

. . . . . . .

749

Configuring MLD Snooping on VLANs

Configuring IGMP Snooping on VLANs

. . . . . . .

750

. . . . . . . .

751

. . . . . . . . . . . . . . . . . .

752

Configuring MLD Snooping Querier
Configuring MVR

Contents

29

Configuring GARP Timers and GMRP .

. . . . . .

Case Study on a Real-World Network Topology
Multicast Snooping Case Study

. . .

755

. . . . . . . . .

755

26 Configuring Connectivity Fault
Management . . . . . . . . . . . . . .
Dot1ag Overview .

. . . . . . .

761

. . . . . . . . . . . . . . . . . . .

761

How Does Dot1ag Work Across a Carrier
Network? . . . . . . . . . . . . . . . . .

. . . .

762

. . . . .

763

. . . . . . . .

765

. . . . . . . . . . . . . . . . .

766

What Entities Make Up a Maintenance
Domain? . . . . . . . . . . . . . . . . .
What is the Administrator’s Role?
Default Dot1ag Values

Configuring Dot1ag (Web)

. . . . . . . . . . . . . . .

767

Dot1ag MD Configuration .

. . . . . . . . . . . .

767

Dot1ag MA Configuration .

. . . . . . . . . . . .

768

Dot1ag MEP Configuration

. . . . . . . . . . . .

769

Dot1ag MIP Configuration

. . . . . . . . . . . .

770

. . . . . . . . . . . . .

771

. . . . . . . . . . . . . . . . . .

772

Dot1ag RMEP Summary.
Dot1ag L2 Ping

Dot1ag L2 Traceroute .

. . . . . . . . . . . . . .

Dot1ag Statistics

772

. . . . . . . . . . .

773

. . . . . . . . . . . . . . . . .

774

Dot1ag L2 Traceroute Cache

Configuring Dot1ag (CLI) .

. . . . . . . . . . . . . . .

Configuring Dot1ag Global Settings and
Creating Domains . . . . . . . . . . . .
Dot1ag Ping and Traceroute

775

. . . . .

775

. . . . . . . . . .

776

. . . . . . . . . . .

777

Configuring MEP Information .

Contents

767

. . . . . . . . . . .

Dot1ag Global Configuration

30

754

Dot1ag Configuration Example

27 Snooping and Inspecting Traffic .
Traffic Snooping and Inspection Overview .
What Is DHCP Snooping?. . . . . . .
How Is the DHCP Snooping Bindings
Database Populated? . . . . . . . . .
What Is IP Source Guard? . . . . . .
What is Dynamic ARP Inspection? . .

. . . . .
. . . . . .

781
782

. . . . . . .

783
785
786

. . . . . . .
. . . . . . .
. . . . . .

Default Traffic Snooping and Inspection Values

787

. . . .

787

. . . . .

789

. . . . . . . . . . .

789

Configuring Traffic Snooping and Inspection
(Web) . . . . . . . . . . . . . . . . . . . . . .
DHCP Snooping Configuration

781

. . . . . . .

Why Is Traffic Snooping and Inspection
Necessary? . . . . . . . . . . . . . . .

DHCP Snooping Interface Configuration . . .
DHCP Snooping VLAN Configuration . . . . .
DHCP Snooping Persistent Configuration . .
DHCP Snooping Static Bindings
Configuration . . . . . . . . . . . . . . . . .
DHCP Snooping Dynamic Bindings Summary
DHCP Snooping Statistics . . . . . . . . . .
IPSG Interface Configuration . . . . . . . . .
IPSG Binding Configuration . . . . . . . . .
IPSG Binding Summary . . . . . . . . . . . .
DAI Global Configuration . . . . . . . . . . .
DAI Interface Configuration . . . . . . . . .
DAI VLAN Configuration . . . . . . . . . . .
DAI ACL Configuration . . . . . . . . . . . .

. . .
. . .
. . .

790
792
794

. . .

795
797
798
799
800
801
802
803
805
806

. . . . . . . . . . . .

807

. . . . . . . . . . . . . . . . . . .

809

DAI ACL Rule Configuration
DAI Statistics .

778

. . . . . . . . . . . . .

. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .

Contents

31

Configuring Traffic Snooping and Inspection
(CLI) . . . . . . . . . . . . . . . . . . . . . . .
Configuring DHCP Snooping

. . . .

810

. . . . . . . . . . .

810

Configuring IP Source Guard .

. . . . . . . . . .

Configuring Dynamic ARP Inspection

. . . . . .

Traffic Snooping and Inspection Configuration
Examples . . . . . . . . . . . . . . . . . . . . .

815

. . . . . . . . . . .

815

. . . . . . . . . . . . . . . . .

817

28 Configuring Link Aggregation
Link Aggregation Overview

. . . . . . . .

819

. . . . . . . . . . . . . .

819

Why Are Link Aggregation Groups
Necessary? . . . . . . . . . . . .

. . . . . . . .

What Is the Difference Between Static and
Dynamic Link Aggregation? . . . . . . . . .
What is LAG Hashing?

820

. . . . . . . . . . . . . .

821

Default Link Aggregation Values

. .

822
823

. . . . . . . . . . .

823

Configuring Link Aggregation (Web)
LAG Configuration.

. .

. . . . . . . . .

824

. . . . . . . . . . . . . . . .

824

. . . . . . . . . . . . .

825
827
828

. . . . . . . . . . . . . . .

829

LACP Parameters . . . .
LAG Membership . . . .
LAG Hash Configuration
LAG Hash Summary .

. . . . . . . . . . . . .
. . . . . . . . . . . . .

Configuring Link Aggregation (CLI)

. . . . . . . . . .

Configuring LAG Characteristics

. . . . . . . . .

Configuring Link Aggregation Groups
Configuring LACP Parameters . . . .

Contents

820

. . .

How Do LAGs Interact with Other Features? .
LAG Configuration Guidelines . . . . . . . .

32

813

. . .

Configuring DHCP Snooping
Configuring IPSG

812

. . . . . .
. . . . . .

830
830
831
833

Link Aggregation Configuration Examples

. . . . . . .

834

. . . . . . . . . . . .

834

. . . . . . . . . . . . . .

835

Configuring Dynamic LAGs .
Configuring Static LAGs

29 Managing the MAC Address Table
MAC Address Table Overview .

. . . .

837

. . . . . . . . . . . . .

How Is the Address Table Populated?

838

. . . . .

How Is the MAC Address Table Maintained
Across a Stack? . . . . . . . . . . . . . . .
Default MAC Address Table Values .

837

. . . . . . .

What Information Is in the MAC Address
Table? . . . . . . . . . . . . . . . . . . .

. . .

838

. . . . . . . . . .

838

Managing the MAC Address Table (Web) .
Static Address Table

837

. . . . . . .

839

. . . . . . . . . . . . . . . .

839

Dynamic Address Table

841

. . . . . . . . . . . . . .

Managing the MAC Address Table (CLI)

. . . . . . . .

842

Managing the MAC Address Table .

. . . . . . . .

842

30 Configuring Routing Interfaces .
Routing Interface Overview .

843

. . . . . . . . . . . . . .
. . . . . . .

843
844

. . . . . . . . . . .

845

What Are Loopback Interfaces?
What Are Tunnel Interfaces? .

Why Are Routing Interfaces Needed?
Default Routing Interface Values

843

. . . . . . . . . .

What Are VLAN Routing Interfaces? .

. . . . . . .

846

. . . . . . . . . . . .

848

Configuring Routing Interfaces (Web) .

. . . . . . . . .

849

. . . . . . . . . . . . .

849

. . . . . . . . . . . . . .

850

IP Interface Configuration
DHCP Lease Parameters

. . . . . .

Contents

33

VLAN Routing Summary

. . . . . . . . . . . . .

850

. . . . . . . . . . . . . . .

851

. . . . . . . . . . . . . . . .

852

Tunnel Configuration
Tunnels Summary .

Loopbacks Configuration
Loopbacks Summary . .

. . . . . . . . . . . . .
. . . . . . . . . . . . .

Configuring Routing Interfaces (CLI)

. . . . . . . . .

855

. . . . . . . .

857
858

. . . . . . . .

31 Configuring DHCP Server Settings
DHCP Overview

. . . .

859

. . . . . . . . . . . . . . . . . . . .

859

How Does DHCP Work? .

. . . . . . . . . . . . .

What are DHCP Options? .

. . . . . . . . . . . .

What Additional DHCP Features Does the
Switch Support? . . . . . . . . . . . . .
Default DHCP Server Values .

. . . . . . . . . . . . .

861

. . . . . . . . .

862

. . . . . . . .

862

. . . . . . . . . . . . . . . . . . .

864

. . . . . . . . . . . . . .

868

. . . . . . . . . . . . . . . . . .

870

Address Pool Options .
DHCP Bindings

DHCP Server Reset Configuration

. . . . . . . .

DHCP Server Statistics

871

. . . . . . .

872

. . . . . . . . . . . . . .

873

DHCP Server Conflicts Information .

Configuring the DHCP Server (CLI)

. . . . . . . . . .
. . . .

874
875

. . . . . . . .

876

Configuring a Dynamic Address Pool .
Configuring a Static Address Pool

874

. . . . . .

Configuring Global DHCP Server Settings

Monitoring DHCP Server Information
Contents

860
861

DHCP Server Network Properties
Address Pool

859

. . . .

Configuring the DHCP Server (Web) .

34

855

. . .

Configuring VLAN Routing Interfaces (IPv4)
Configuring Loopback Interfaces .
Configuring Tunnels . . . . . . . .

853
854

. . . . . .

877

DHCP Server Configuration Examples

. . . . . . .

878

. . . . . . . . .

880

Configuring a Dynamic Address Pool
Configuring a Static Address Pool

32 Configuring IP Routing
IP Routing Overview .

. . . . . . . . . . . . .

883

. . . . . . . . . . . . . . . . . .

Default IP Routing Values

. . . . . . . . . . . . . . . .

Configuring IP Routing Features (Web)
IP Configuration.

878

. . . . . . . . .

883
885

. . . . . . . . .

887

. . . . . . . . . . . . . . . . . .

887

IP Statistics . . . . . . . . . . . .
ARP Create . . . . . . . . . . . .
ARP Table Configuration . . . . .
Router Discovery Configuration .
Router Discovery Status . . . . .
Route Table . . . . . . . . . . . .
Best Routes Table . . . . . . . .
Route Entry Configuration . . . .
Configured Routes . . . . . . . .
Route Preferences Configuration

. . . . . . . . .

888
889
890
891
892
893
894
895
897
898

Configuring IP Routing Features (CLI) .

. . . . . . . . .

899

. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .

Configuring Global IP Routing Settings .

. . . . . .

Adding Static ARP Entries and Configuring
ARP Table Settings . . . . . . . . . . . . .
Configuring Router Discovery (IRDP) . . . .
Configuring Route Table Entries and Route
Preferences . . . . . . . . . . . . . . . . .
IP Routing Configuration Example

899

. . . .

900
901

. . . .

902

. . . . . . . . . . .

904

Configuring PowerConnect Switch A
Configuring PowerConnect Switch B

. . . .

. . . . . . .
. . . . . . .

Contents

905
906

35

33 Configuring L2 and L3 Relay
Features . . . . . . . . . . . . . . .
L2 and L3 Relay Overview

. . . . . . . . .

907

. . . . . . . . . . . . . . .

907

What Is L3 DHCP Relay?

. . . . . . . . . . . . .

907

What Is L2 DHCP Relay?

. . . . . . . . . . . . .

908

What Is the IP Helper Feature? .
Default L2/L3 Relay Values .

. . . . . . . . .

909

. . . . . . . . . . . . . .

913

Configuring L2 and L3 Relay Features (Web)
DHCP Relay Global Configuration.

. . . . .

914

. . . . . . . .

914

DHCP Relay Interface Configuration
DHCP Relay Interface Statistics . .
DHCP Relay VLAN Configuration . .
DHCP Relay Agent Configuration . .
IP Helper Global Configuration . .
IP Helper Interface Configuration
IP Helper Statistics . . . . . . . .

. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .

. . . . . . . .
. . . . . . . .
. . . . . . . .

Configuring L2 and L3 Relay Features (CLI)
Configuring L2 DHCP Relay .

925

. . . . . . . . . . .

925

Relay Agent Configuration Example .

. . . .

927

. . . . . . . . .

929

34 Configuring OSPF and OSPFv3 .

. . . . . . .

931

. . . . . . . . . . . . . . . . . . . .

932

What Are OSPF Areas and Other OSPF
Topology Features? . . . . . . . . . . .
What Are OSPF Routers and LSAs?
How Are Routes Selected? . . . . .

. . . . .

932

. . . . . . .

933
933

. . . . . . .

How Are OSPF and OSPFv3 Different?

36

Contents

920
922
924

. . . . . .

Configuring L3 Relay (IP Helper) Settings

OSPF Overview .

915
917
918
919

. . . . . .

933

OSPF Feature Details
Max Metric

. . . . . . . . . . . . . . . . . .

934

. . . . . . . . . . . . . . . . . . . . .

934

Static Area Range Cost .
LSA Pacing

. . . . . . . . . . . . . .

936

. . . . . . . . . . . . . . . . . . . . .

937

Flood Blocking

. . . . . . . . . . . . . . . . . . .

Default OSPF Values .

. . . . . . . . . . . . . . . . . .

Configuring OSPF Features (Web) .
OSPF Configuration .

938
940

. . . . . . . . . . .

942

. . . . . . . . . . . . . . . .

942

OSPF Area Configuration . . . .
OSPF Stub Area Summary . . .
OSPF Area Range Configuration
OSPF Interface Statistics . . . .
OSPF Interface Configuration .
OSPF Neighbor Table . . . . . .
OSPF Neighbor Configuration .
OSPF Link State Database . . .
OSPF Virtual Link Configuration

. . . . . . . . . .
. . . . . . . . . .
. . . . . . . . . .
. . . . . . . . . .
. . . . . . . . . .
. . . . . . . . . .
. . . . . . . . . .
. . . . . . . . . .
. . . . . . . . . .

OSPF Virtual Link Summary . . . . . . . .
OSPF Route Redistribution Configuration
OSPF Route Redistribution Summary . . .
NSF OSPF Configuration . . . . . . . . .

. . . . .

954
955
956
957

. . . . . . . . . .

958

. . . . . . . . . . . . . . .

958

Configuring OSPFv3 Features (Web)
OSPFv3 Configuration

943
946
947
948
949
950
951
952
952

OSPFv3 Area Configuration .

. . . . .
. . . . .
. . . . .

. . . . . . . . . . . .

OSPFv3 Stub Area Summary . . . .
OSPFv3 Area Range Configuration .
OSPFv3 Interface Configuration . .
OSPFv3 Interface Statistics . . . .
OSPFv3 Neighbors . . . . . . . . .
OSPFv3 Neighbor Table . . . . . . .
OSPFv3 Link State Database . . . .
OSPFv3 Virtual Link Configuration .
OSPFv3 Virtual Link Summary . . .

. . . . . . . .
. . . . . . . .
. . . . . . . .
. . . . . . . .
. . . . . . . .
. . . . . . . .
. . . . . . . .
. . . . . . . .
. . . . . . . .

Contents

959
962
963
964
965
966
967
968
969
971

37

OSPFv3 Route Redistribution Configuration
OSPFv3 Route Redistribution Summary . .
NSF OSPFv3 Configuration . . . . . . . . .
Configuring OSPF Features (CLI) .

. . .

972
973
974

. . . . . . . . . . .

975

Configuring Global OSPF Settings

. . . . . .
. . . . . .

Configuring Virtual Links . . . . . . . .
Configuring OSPF Area Range Settings
Configuring NSF Settings for OSPF . .

. . . . . . . . . .

987

. . . . .
. . . . .

. . . . . . .
. . . . .
. . . . .

Configuring Virtual Links . . . . . . . . .
Configuring an OSPFv3 Area Range . . .
Configuring OSPFv3 Route Redistribution
Settings . . . . . . . . . . . . . . . . . .
Configuring NSF Settings for OSPFv3 . .

. . . .
. . . .

987
989
991
993
994

. . . .

995
996

. . . . . . . . . . . .

997

Configuring an OSPF Border Router and
Setting Interface Costs . . . . . . . . . .

. . . .

. . . .

Configuring Stub and NSSA Areas for OSPF
and OSPFv3 . . . . . . . . . . . . . . . . . .
Configuring a Virtual Link for OSPF and
OSPFv3 . . . . . . . . . . . . . . . . . . . .

Configuring Flood Blocking .

997

. .

1000

. .

1004

. . . . .
. . . . .

1006
1009

. . . . . . . . . . .

1014

Interconnecting an IPv4 Backbone and
Local IPv6 Network . . . . . . . . . . .
Configuring the Static Area Range Cost

Contents

978
980

. . . . .

Configuring OSPFv3 Interface Settings .
Configuring Stub Areas and NSSAs . .

38

975

982
984
986

Configuring Global OSPFv3 Settings

OSPF Configuration Examples .

. . .

. . . . . . . .

Configuring OSPF Interface Settings .
Configuring Stub Areas and NSSAs .

Configuring OSPFv3 Features (CLI)

. . .

35 Configuring RIP
RIP Overview.

. . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . .

How Does RIP Determine Route
Information? . . . . . . . . . .
What Is Split Horizon?

1019

. . . . . . . . . . . . . .

1020

. . . . . . .

1020

. . . . . . . . . . . . . . . . . .

1021

Configuring RIP Features (Web) .
RIP Configuration .

. . . . . . . . . . .

1022

. . . . . . . . . . . . . . . .

1022

RIP Interface Configuration . . . . . .
RIP Interface Summary . . . . . . . . .
RIP Route Redistribution Configuration
RIP Route Redistribution Summary . . .
Configuring RIP Features (CLI).

. . . . .

1023
1024
1025
1026

. . . . . . . . . . . .

1027

Configuring Global RIP Settings

. . . . .
. . . . .
. . . . .

. . . . . . . . .

Configuring RIP Interface Settings .

. . . . . . .

RIP Configuration Example

VRRP Overview

1027
1028

. . .

1029

. . . . . . . . . . . . . .

1031

Configuring Route Redistribution Settings .

36 Configuring VRRP

1019

. . . . . . . . .

What RIP Versions Are Supported?
Default RIP Values .

1019

. . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . .

How Does VRRP Work? .

. . . . . . . . . . . . .

What Is the VRRP Router Priority?
What Is VRRP Preemption? .

1033
1033
1033

. . . . . . . .

1034

. . . . . . . . . . .

1034

What Is VRRP Accept Mode?

. . . . . . . . . .

What Are VRRP Route and Interface
Tracking? . . . . . . . . . . . . . . .

. . . . . .

1035
1035

Contents

39

Default VRRP Values .

. . . . . . . . . . . . . . . . .

Configuring VRRP Features (Web) .
VRRP Configuration .

. . . . . . . . . .

1038

. . . . . . . . . . . . . . .

1038

VRRP Virtual Router Status . . . . . . .
VRRP Virtual Router Statistics . . . . .
VRRP Router Configuration . . . . . . .
VRRP Route Tracking Configuration . .
VRRP Interface Tracking Configuration.
Configuring VRRP Features (CLI).

. . . . .

1039
1040
1041
1042
1044

. . . . .
. . . . .
. . . . .
. . . . .

. . . . . . . . . . .

1046

. . . . . . . . . . . .

1046

VRRP Configuration Example

. . . . . . . . . . . . .

1048

VRRP with Load Sharing

. . . . . . . . . . . . .

1048

Configuring VRRP Settings

VRRP with Route and Interface Tracking .

37 Configuring IPv6 Routing .
IPv6 Routing Overview .

. . . . . . . . . . . . . . . .
. . . . . . .

How Are IPv6 Interfaces Configured?
Default IPv6 Routing Values

Global Configuration

1052

1057
1057
1058

. . . . . .

1058

. . . . . . . . . . . . . .

1059

Configuring IPv6 Routing Features (Web) .

. . . . . .

1061

. . . . . . . . . . . . . . .

1061

Interface Configuration . . . . .
Interface Summary . . . . . . .
IPv6 Statistics . . . . . . . . . .
IPv6 Neighbor Table. . . . . . .
DHCPv6 Client Parameters . . .
IPv6 Route Entry Configuration .
IPv6 Route Table . . . . . . . .
IPv6 Route Preferences . . . . .
Configured IPv6 Routes . . . . .
Contents

. . . .

. . . . . . . . . .

How Does IPv6 Compare with IPv4?

40

1037

. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .

1062
1063
1064
1065
1066
1067
1068
1069
1070

Configuring IPv6 Routing Features (CLI).

. . . . . . .
. . . . .

1071

. . . . . .

1072
1073

Configuring Global IP Routing Settings .
Configuring IPv6 Interface Settings .
Configuring IPv6 Neighbor Discovery

. . . . . .

Configuring IPv6 Route Table Entries and
Route Preferences . . . . . . . . . . . .
IPv6 Show Commands

. . . .

1075

. . . . . . . . . . . . . .

1077

IPv6 Static Reject and Discard Routes

. . . . . . . .

38 Configuring DHCPv6 Server and
Relay Settings . . . . . . . . . . . . . .
DHCPv6 Overview

1071

1081

. . . . .

. . . . . . . . . . . . . . . . . . .

What Is a DHCPv6 Pool?

. . . . . . . . . . . . .

What Is a Stateless Server?

. . . . . . . . . . .

What Is the DHCPv6 Relay Agent Information
Option? . . . . . . . . . . . . . . . . . . . . .
What Is a Prefix Delegation? .

1081
1082
1082

.

1082

. . . . . . . . . .

1082

Default DHCPv6 Server and Relay Values .

. . . . . .

Configuring the DHCPv6 Server and Relay (Web) .
DHCPv6 Global Configuration

1078

1083

. .

1084

. . . . . . . . . .

1084

DHCPv6 Pool Configuration . . . . .
Prefix Delegation Configuration . .
DHCPv6 Pool Summary . . . . . . .
DHCPv6 Interface Configuration . .
DHCPv6 Server Bindings Summary
DHCPv6 Statistics. . . . . . . . . .

. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .

1085
1087
1088
1089
1091
1092

Configuring the DHCPv6 Server and Relay (CLI)

. . .

1093

Configuring Global DHCP Server and Relay
Agent Settings . . . . . . . . . . . . . . .

. . .

1093

. . . .

1093

Configuring a DHCPv6 Pool for Stateless
Server Support . . . . . . . . . . . . . .

Contents

41

Configuring a DHCPv6 Pool for Specific
Hosts . . . . . . . . . . . . . . . . . .

. . . . .

Configuring DHCPv6 Interface Information .

. . .

1095

. . . . . . . . .

1096

. . . . . . . . . . .

1097

Monitoring DHCPv6 Information
DHCPv6 Configuration Examples

Configuring a DHCPv6 Stateless Server

. . . . .

Configuring the DHCPv6 Server for Prefix
Delegation . . . . . . . . . . . . . . . . .

. . . .

Configuring an Interface as a DHCPv6 Relay
Agent . . . . . . . . . . . . . . . . . . . . .

39 Configuring Differentiated Services
DiffServ Overview

. .

How Does DiffServ Functionality Vary Based
on the Role of the Switch? . . . . . . . . . .
What Are the Elements of DiffServ
Configuration? . . . . . . . . . . . . . . . .

1098
1099

1101
1101
1102

. .

1102

. . . . . . . . . . . . . . . .

1103

Configuring DiffServ (Web)

. . . . . . . . . . . . . .

1104

DiffServ Configuration

. . . . . . . . . . . . . .

1104

. . . . . . . . . . . . . . .

1105
1106

. . . . . . . . . . . . . . .

. . . . . . . . . . . .

1108
1110
1113
1114
1115

. . . . . . . . . . . . . . .

1116

Policy Configuration . . .
Policy Class Definition . .
Service Configuration . . .
Service Detailed Statistics
Flow-Based Mirroring . .
Configuring DiffServ (CLI)

. . . . . . . . . . . .
. . . . . . . . . . . .
. . . . . . . . . . . .
. . . . . . . . . . . .

DiffServ Configuration (Global) .

Contents

1097

. .

Class Configuration .
Class Criteria . . . .

42

. .

. . . . . . . . . . . . . . . . . . .

Default DiffServ Values

1094

. . . . . . . . .

1116

DiffServ Class Configuration for IPv4 .

. . . . . .

1116

DiffServ Class Configuration for IPv6 .

. . . . . .

1118

DiffServ Policy Creation

. . . . . . . . . . . . .

DiffServ Policy Attributes Configuration

. . . . .

1120

. . . . . . . . .

1122

. . . . . . . . . . .

1123

DiffServ Service Configuration .
DiffServ Configuration Examples

Providing Subnets Equal Access to External
Network . . . . . . . . . . . . . . . . . . . .
DiffServ for VoIP

. .

1123

. . . . . . . . . . . . . . . . .

1126

40 Configuring Class-of-Service
CoS Overview

. . . . . . .

. . . . . . . . . . . . . . . . . . . . .

What Are Trusted and Untrusted Port
Modes? . . . . . . . . . . . . . . . .

. . . . . .

How Is Traffic Shaping Used on Egress
Traffic? . . . . . . . . . . . . . . . . .

. . . . .

1129
1129
1130
1130

. . . .

1131

. . . .

1131

. . . . . . . . . . . . . . . .

1132

. . . . . . . . . . . . . . . . . .

1132

How Are Traffic Queues Defined? . . . .
Which Queue Management Methods Are
Supported? . . . . . . . . . . . . . . . .
CoS Queue Usage
Default CoS Values

1119

Configuring CoS (Web)

. . . . . . . . . . . . . . . .

Mapping Table Configuration .

. . . . . . . . . .

1133

. . . . . . .

1136
1137

. . . . . . .

1138

. . . . . . . . . . . . . . . . .

1140

Interface Configuration . . . . . . .
Interface Queue Configuration . . .
Interface Queue Drop Precedence
Configuration . . . . . . . . . . . .
Configuring CoS (CLI)

1133

Mapping Table Configuration .

. . . . . . .

. . . . . . . . . .

CoS Interface Configuration Commands .
Interface Queue Configuration .

1140

. . . .

1141

. . . . . . . . .

1141

Configuring Interface Queue Drop
Probability . . . . . . . . . . . .

. . . . . . . .

1143

Contents

43

CoS Configuration Example

41 Configuring Auto VoIP
Auto VoIP Overview

. . . . . . . . . . . . . .

. . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . .

1148

. . . . . . . . . . . . .

Auto VoIP Global Configuration .

. . . . . . . . .

Auto VoIP Interface Configuration
Configuring Auto VoIP (CLI)

1149
1149

. . . . . . . . . . . . . .

1152

. . .

. . . . . . . . . . . . . . . .

What Is IP Multicast Traffic?

. . . . . . . . . . .

What Multicast Protocols Does the Switch
Support?. . . . . . . . . . . . . . . . . . .
What Are the Multicast Protocol Roles? . .
When Is L3 Multicast Required on the
Switch? . . . . . . . . . . . . . . . .
What Is the Multicast Routing Table?

. . .
. . .

1153
1153
1154
1155
1155

. . . . . .

1156
1156

What Is IGMP?

. . . . . . . . . . . . . . . . . .

1157

What Is MLD? .

. . . . . . . . . . . . . . . . . .

1158

What Is PIM? . .
What Is DVMRP?

. . . . . .

. . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . .

Default L3 Multicast Values

Contents

1149

. . . . . . . .

42 Managing IPv4 and IPv6 Multicast

44

1147
1148

Configuring Auto VoIP (Web)

L3 Multicast Overview .

1147

. . . . . . . .

How Does Auto-VoIP Use ACLs? .
Default Auto VoIP Values

1144

. . . . . . . . . . . . . .

1159
1169
1171

Configuring General IPv4 Multicast
Features (Web) . . . . . . . . . . . .

. . . . . . . . .

1173

Multicast Global Configuration .

. . . . . . . . .

1173

Multicast Interface Configuration . . . .
Multicast Route Table . . . . . . . . . .
Multicast Admin Boundary Configuration
Multicast Admin Boundary Summary . .
Multicast Static MRoute Configuration .
Multicast Static MRoute Summary . . . .

. . . .

1174
1175
1176
1177
1178
1179

. . . . .

1180

. . . . . . . . . . .

1180

Configuring IPv6 Multicast Features (Web) .
IPv6 Multicast Route Table .

Configuring IGMP and IGMP Proxy (Web)
IGMP Global Configuration .

. . . .
. . . .
. . . .
. . . .
. . . .

. . . . . .

1181

. . . . . . . . . . .

1181

IGMP Interface Configuration
IGMP Interface Summary . .
IGMP Cache Information . . .

. . . . . . . . . .
. . . . . . . . . .
. . . . . . . . . .

. .

1185
1186
1187
1188

. .

1189

. . . . . . .

1190

. . . . . . . . . . . .

1190

IGMP Interface Source List Information . . .
IGMP Proxy Interface Configuration . . . . .
IGMP Proxy Configuration Summary . . . . .
IGMP Proxy Interface Membership Info . . .
Detailed IGMP Proxy Interface Membership
Information . . . . . . . . . . . . . . . . . .
Configuring MLD and MLD Proxy (Web)
MLD Global Configuration

1182
1183
1184

MLD Routing Interface Configuration . . .
MLD Routing Interface Summary. . . . . .
MLD Routing Interface Cache Information .

. .
. .
. .

. . .
. . .
. . .

MLD Routing Interface Source List
Information . . . . . . . . . . . . . . . . .
MLD Traffic . . . . . . . . . . . . . . . . .
MLD Proxy Configuration . . . . . . . . . .
MLD Proxy Configuration Summary . . . .
MLD Proxy Interface Membership
Information . . . . . . . . . . . . . . . . .
Detailed MLD Proxy Interface Membership
Information . . . . . . . . . . . . . . . . .

1191
1192
1193

. . .

1194
1195
1196
1197

. . .

1198

. . .

1199

. . .
. . .
. . .

Contents

45

Configuring PIM for IPv4 and IPv6 (Web)
PIM Global Configuration .

. . . . . . .

1200

. . . . . . . . . . . .

1200

PIM Global Status . . . . . . .
PIM Interface Configuration .
PIM Interface Summary . . .
Candidate RP Configuration .
Static RP Configuration . . . .
SSM Range Configuration . .
BSR Candidate Configuration .
BSR Candidate Summary . . .
Configuring DVMRP (Web) .

. . . . . . . . . .

1201
1202
1203
1204
1206
1208
1210
1211

. . . . . . . . . . . . . .

1212

DVMRP Global Configuration .

. . . . . . . . . .
. . . . . . . . . .
. . . . . . . . . .
. . . . . . . . . .
. . . . . . . . . .
. . . . . . . . . .
. . . . . . . . . .

. . . . . . . . . .

DVMRP Interface Configuration
DVMRP Configuration Summary
DVMRP Next Hop Summary . .
DVMRP Prune Summary
DVMRP Route Summary

. . . . . . . . .
. . . . . . . . .
. . . . . . . . .

. . . . . . . . . . . . .
. . . . . . . . . . . . .

Configuring L3 Multicast Features (CLI) .

. . . . . . .

Configuring and Viewing IPv4 Multicast
Information . . . . . . . . . . . . . . .
Configuring and Viewing IPv6 Multicast
Route Information . . . . . . . . . . . .
Configuring and Viewing IGMP . . . . .
Configuring and Viewing IGMP Proxy .
Configuring and Viewing MLD . . . . .
Configuring and Viewing MLD Proxy . .

Contents

1213
1214
1215
1217
1218
1219

. . . . .

1219

. . . . .

1221
1222
1224
1225
1226

. . . . .
. . . . .
. . . . .
. . . . .

Configuring and Viewing PIM-DM for IPv4
Multicast Routing . . . . . . . . . . . . . .

. . .

1227

Configuring and Viewing PIM-DM for IPv6
Multicast Routing . . . . . . . . . . . . . .

. . .

1228

. . .

1230

. . .

1232

Configuring and Viewing PIM-SM for IPv4
Multicast Routing . . . . . . . . . . . . . .
Configuring and Viewing PIM-SM for IPv6
Multicast Routing . . . . . . . . . . . . . .

46

1212

Configuring and Viewing DVMRP
Information . . . . . . . . . . . .

. . . . . . . .

1236

L3 Multicast Configuration Examples .

. . . . . . . .

1237

Configuring Multicast VLAN Routing With
IGMP and PIM-SM . . . . . . . . . . . . .
Configuring DVMRP

. . .

1237

. . . . . . . . . . . . . . .

1241

43 System Process Definitions

. . . . . . . .

1243

Contents

47

48

Contents

1

Introduction

The switches in the Dell PowerConnect 7000 Series are stackable Layer 2
and 3 switches that extend the Dell PowerConnect LAN switching product
range. These switches include the following features:
•

1U form factor, rack-mountable chassis design.

•

Support for all data-communication requirements for a multi-layer switch,
including layer 2 switching, IPv4 routing, IPv6 routing, IP multicast,
quality of service, security, and system management features.

•

High availability with hot swappable stack members.

The PowerConnect 7000 Series includes six switch models: PC7024,
PC7024P, PC7024F, PC7048, PC7048P, and PC7048R/PC7048R-RA. The
PC7048R/PC7048R-RA is a top-of-rack switch. The difference between the
PC7048R and PC7048R-RA is the airflow direction.

About This Document
This guide describes how to configure, monitor, and maintain a Dell
PowerConnect 7000 Series switch by using web-based Dell OpenManage
Switch Administrator utility or the command-line interface (CLI).

Audience
This guide is for network administrators in charge of managing one or more
PowerConnect 7000 Series switches. To obtain the greatest benefit from this
guide, you should have a basic understanding of Ethernet networks and local
area network (LAN) concepts.

Introduction

49

Document Conventions
Table 1-1 describes the typographical conventions this document uses.
Table 1-1.

Document Conventions

Convention

Description

Bold

Page names, field names, menu options, button names, and
CLI commands and keywords.

courier font

Command-line text (CLI output) and file names

[]

In a command line, square brackets indicate an optional
entry.

{}

In a command line, inclusive brackets indicate a selection of
compulsory parameters separated by the | character. One
option must be selected. For example: spanning-tree mode
{stp|rstp|mstp} means that for the spanning-tree mode
command you must enter either stp, rstp, or mstp

Italic

In a command line, indicates a variable.



Any individual key on the keyboard.

CTRL + Z

A keyboard combination that involves pressing the Z key
while holding the CTRL key.

Additional Documentation
The following documents for the PowerConnect 7000 Series switches are
available at support.dell.com/manuals:

50

•

Getting Started Guide—provides information about the switch models in
the series, including front and back panel features. It also describes the
installation and initial configuration procedures.

•

CLI Reference Guide—provides information about the command-line
interface (CLI) commands used to configure and manage the switch. The
document provides in-depth CLI descriptions, syntax, default values, and
usage guidelines.

Introduction

2

Switch Features
This section describes the switch user-configurable software features.

NOTE: Before proceeding, read the release notes for this product. The release
notes are part of the firmware download.
The topics covered in this section include:
•

System Management
Features

•

Spanning Tree Protocol
Features

•

Stacking Features

•

Link Aggregation Features

•

Security Features

•

Routing Features

•

Green Technology Features

•

IPv6 Routing Features

•

Power over Ethernet (PoE)
Plus Features

•

Quality of Service (QoS)
Features

•

Switching Features

•

Layer 2 Multicast Features

•

Virtual Local Area Network
Supported Features

•

Layer 3 Multicast Features

Switch Features

51

System Management Features
Multiple Management Options
You can use any of the following methods to manage the switch:
•

Use a web browser to access the Dell OpenManage Switch Administrator
interface. The switch contains an embedded Web server that serves
HTML pages.

•

Use a telnet client, SSH client, or a direct console connection to access the
CLI. The CLI syntax and semantics conform as much as possible to
common industry practice.

•

Use a network management system (NMS) to manage and monitor the
system through SNMP. The switch supports SNMP v1/v2c/v3 over the
UDP/IP transport protocol.

Nearly all switch features support a preconfiguration capability, even when
the feature is not enabled or the required hardware is not present.
Preconfigured capabilities become active only when enabled (typically via an
admin mode control) or when the required hardware is present (or both). For
example, a port can be preconfigured with both trunk and access mode
information. The trunk mode information is applied only when the port is
placed into trunk mode and the access mode information is only applied
when the port is placed into access mode. Likewise, OSPF routing can be
configured in the switch without being enabled on any port. This capability is
present in all of the management options.

System Time Management
You can configure the switch to obtain the system time and date through a
remote Simple Network Time Protocol (SNTP) server, or you can set the time
and date locally on the switch. You can also configure the time zone and
information about time shifts that might occur during summer months. If
you use SNTP to obtain the time, you can require communications between
the switch and the SNTP server to be encrypted.
For information about configuring system time settings, see "Managing
General System Settings" on page 239.

52

Switch Features

Log Messages
The switch maintains in-memory log messages as well as persistent logs. You
can also configure remote logging so that the switch sends log messages to a
remote log server. You can also configure the switch to send log messages to a
configured SMTP server. This allows you to receive the log message in an email account of your choice. Switch auditing messages, CLI command
logging, Web logging, and SNMP logging can be enabled or disabled.
For information about configuring system logging, see "Monitoring and
Logging System Information" on page 201.

Switch Features

53

Integrated DHCP Server
PowerConnect 7000 Series switches include an integrated DHCP server that
can deliver host-specific configuration information to hosts on the network.
The switch DHCP server allows you to configure IP address pools (scopes),
and when a host’s DHCP client requests an address, the switch DHCP server
automatically assigns the host an address from the pool.
For information about configuring the DHCP server settings, see
"Configuring DHCP Server Settings" on page 859.

Management of Basic Network Information
The DHCP client on the switch allows the switch to acquire information such
as the IP address and default gateway from a network DHCP server. You can
also disable the DHCP client and configure static network information.
Other configurable network information includes a Domain Name Server
(DNS), hostname to IP address mapping, and a default domain name.
If the switch detects an IP address conflict on the management interface, it
generates a trap and sends a log message.
For information about configuring basic network information, see "Setting
the IP Address and Other Basic Network Information" on page 121.

IPv6 Management Features
PowerConnect 7000 Series switches provide IPv6 support for many standard
management features including HTTP, HTTPS/SSL, Telnet, SSH, SNMP,
SNTP, TFTP, and traceroute.

Dual Software Images
PowerConnect 7000 Series switches can store up to two software images. The
dual image feature allows you to upgrade the switch without deleting the
older software image. You designate one image as the active image and the
other image as the backup image.
For information about managing the switch image, see "Managing Images
and Files" on page 319.

54

Switch Features

File Management
You can upload and download files such as configuration files and system
images by using HTTP (web only), TFTP, Secure FTP (SFTP), or Secure
Copy (SCP). Configuration file uploads from the switch to a server are a good
way to back up the switch configuration. You can also download a
configuration file from a server to the switch to restore the switch to the
configuration in the downloaded file.
You can also copy files to and from a USB Flash drive that is plugged into the
USB port on the front panel of the switch.
For information about uploading, downloading, and copying files, see
"Managing Images and Files" on page 319.

Switch Database Management Templates
Switch Database Management (SDM) templates enable you to reallocate
system resources to support a different mix of features based on your network
requirements. PowerConnect 7000 Series switches support the following
three templates:
•

Dual IPv4 and IPv6 (default)

•

IPv4 Routing

•

IPv4 Data Center

For information about setting the SDM template, see "Managing General
System Settings" on page 239.

Automatic Installation of Firmware and Configuration
The Auto Install feature allows the switch to upgrade or downgrade to a
newer software image and update the configuration file automatically during
device initialization with limited administrative configuration on the device.
If a USB device is connected to the switch and contains a firmware image
and/or configuration file, the Auto Install feature installs the image or
configuration file from USB device. Otherwise, the switch can obtain the
necessary information from a DHCP server on the network.
For information about Auto Install, see "Automatically Updating the Image
and Configuration" on page 345.

Switch Features

55

sFlow
sFlow is the standard for monitoring high-speed switched and routed
networks. sFlow technology is built into network equipment and gives
complete visibility into network activity, enabling effective management and
control of network resources. The PowerConnect 7000 Series switches
support sFlow version 5.
For information about configuring managing sFlow settings, see "Monitoring
Switch Traffic" on page 363.

SNMP Alarms and Trap Logs
The system logs events with severity codes and timestamps. The events are
sent as SNMP traps to a trap recipient list.
For information about configuring SNMP traps and alarms, see "Configuring
SNMP" on page 283.

CDP Interoperability through ISDP
Industry Standard Discovery Protocol (ISDP) allows the PowerConnect
switch to interoperate with Cisco devices running the Cisco Discovery
Protocol (CDP). ISDP is a proprietary Layer 2 network protocol which interoperates with Cisco network equipment and is used to share information
between neighboring devices (routers, bridges, access servers, and switches).
For information about configuring ISDP settings, see "Discovering Network
Devices" on page 659.

Remote Monitoring (RMON)
RMON is a standard Management Information Base (MIB) that defines
current and historical MAC-layer statistics and control objects, allowing realtime information to be captured across the entire network.
For information about configuring managing RMON settings, see
"Monitoring Switch Traffic" on page 363.

56

Switch Features

Stacking Features
For information about creating and maintaining a stack of switches, see
"Managing a Switch Stack" on page 141.

High Port Count
You can stack PowerConnect 7000 Series switches up to 12 switches high,
supporting up to 576 front-panel ports, if all units in the stack are 48-port
models. The stack can contain any combination of switch models in the
PowerConnect 7000 Series as long as all switches are running the same
firmware version.

Single IP Management
When multiple switches are connected together through the stack ports, they
operate as a single unit with a larger port count. The stack operates and is
managed as a single entity. One switch acts as the master, and the entire stack
is managed through the management interface (Web, CLI, or SNMP) of the
stack master.

Automatic Firmware Update for New Stack Members
By default, if a switch is added to a stack and the switch is running a different
backup version of firmware than the active version on the stack master, the
backup firmware on the new member is automatically updated to match the
stack master, the backup version of firmware on the new member is activated,
and the new member is rebooted.

Stacking Compatibility with the PowerConnect M6348
PowerConnect 7000 Series switches and PowerConnect M6348 switches can
be members of the same stack.

Switch Features

57

Master Failover with Transparent Transition
The stacking feature supports a standby or backup unit that assumes the

stack master role if the stack master fails. As soon as a stack master failure is
detected, the standby unit initializes the control plane and enables all other
stack units with the current configuration. The standby unit maintains a
synchronized copy of the running configuration for the stack.

Nonstop Forwarding on the Stack
The Nonstop Forwarding (NSF) feature allows the forwarding plane of stack
units to continue to forward packets while the control and management
planes restart as a result of a power failure, hardware failure, or software fault
on the stack master and allows the standby switch to quickly takeover as the
master.

Hot Add/Delete and Firmware Synchronization
You can add and remove units to and from the stack without cycling the
power. When you add a unit, the Stack Firmware Synchronization feature
automatically synchronizes the firmware version with the version running on
the stack master. The synchronization operation may result in either an
upgrade or a downgrade of firmware on the mismatched stack member. In
addition, the running-config on the member is updated to match the master
switch. The startup-config on the standby and member switches is not
updated to match the master switch due to configuration changes on the
master switch. Saving the startup config on the master switch also saves it to
the startup config on all the other stack members.The hardware configuration
of every switch is updated to match the master switch (unit number, slot
configuration, stack member number, etc.).

Security Features
Configurable Access and Authentication Profiles
You can configure rules to limit access to the switch management interface
based on criteria such as access type and source IP address of the
management host. You can also require the user to be authenticated locally or
by an external server, such as a RADIUS server.

58

Switch Features

For information about configuring access and authentication profiles, see
"Configuring Authentication, Authorization, and Accounting" on page 175.

Password-Protected Management Access
Access to the Web, CLI, and SNMP management interfaces is password
protected, and there are no default users on the system.
For information about configuring local user accounts, see "Configuring
Authentication, Authorization, and Accounting" on page 175.

Strong Password Enforcement
The Strong Password feature enforces a baseline password strength for all
locally administered users. Password strength is a measure of the effectiveness
of a password in resisting guessing and brute-force attacks. The strength of a
password is a function of length, complexity and randomness. Using strong
passwords lowers overall risk of a security breach.
For information about configuring password settings, see "Configuring
Authentication, Authorization, and Accounting" on page 175.

TACACS+ Client
The switch has a TACACS+ client. TACACS+ provides centralized security
for validation of users accessing the switch. TACACS+ provides a centralized
user management system while still retaining consistency with RADIUS and
other authentication processes.
For information about configuring TACACS+ client settings, see
"Configuring Authentication, Authorization, and Accounting" on page 175.

RADIUS Support
The switch has a Remote Authentication Dial In User Service (RADIUS)
client and can support up to 32 named authentication and accounting
RADIUS servers. The switch also supports RADIUS Attribute 4, which is the
configuration of a NAS-IP address. You can also configure the switch to
accept RADIUS-assigned VLANs.
For information about configuring RADIUS client settings, see "Configuring
Authentication, Authorization, and Accounting" on page 175.

Switch Features

59

SSH/SSL
The switch supports Secure Shell (SSH) for secure, remote connections to
the CLI and Secure Sockets Layer (SSL) to increase security when accessing
the web-based management interface.
For information about configuring SSH and SSL settings, see "Configuring
Authentication, Authorization, and Accounting" on page 175.

Inbound Telnet Control
You can configure the switch to prevent new Telnet sessions from being
established with the switch. Additionally, the Telnet port number is
configurable.
For information about configuring inbound Telnet settings, see "Configuring
Authentication, Authorization, and Accounting" on page 175.

Denial of Service
The switch supports configurable Denial of Service (DoS) attack protection
for eight different types of attacks.
For information about configuring DoS settings, see "Configuring Port and
System Security" on page 481.

Port Protection
A port may be put into the disabled state for any of the following reasons:

60

•

BPDU Storm Protection: By default, if Spanning Tree Protocol (STP)
bridge protocol data units (BPDUs) are received at a rate of 15pps or
greater for three consecutive seconds on a port, the port will be
diagnostically disabled. The threshold is not configurable.

•

DHCP Snooping: If DHCP packets are received on a port at a rate that
exceeds 15 pps, the port will be diagnostically disabled. The threshold is
configurable up to 300 pps for up to 15s long using the ip dhcp
snooping limit command. DHCP snooping is disabled by default.
The default protection limit is 15 pps.

Switch Features

•

Dynamic ARP Inspection: By default, if Dynamic ARP Inspection packets
are received on a port at a rate that exceeds 15 pps for 1 second, the port
will be diagnostically disabled. The threshold is configurable up to 300 pps
and the burst is configurable up to 15s long using the ip arp
inspection limit command.

A port that is diagnostically disabled due to exceeding one of the above limits
may be returned to service using the no shut command.

Captive Portal
The Captive Portal feature blocks clients from accessing the network until
user verification has been established. When a user attempts to connect to
the network through the switch, the user is presented with a customized Web
page that might contain username and password fields or the acceptable use
policy. You can require users to be authenticated by a local or remote RADIUS
database before access is granted.
For information about configuring the Captive Portal features, see
"Configuring Captive Portal" on page 419.

Dot1x Authentication (IEEE 802.1X)
Dot1x authentication enables the authentication of system users through a
local internal server or an external server. Only authenticated and approved
system users can transmit and receive data. Supplicants are authenticated
using the Extensible Authentication Protocol (EAP). PEAP, EAP-TTL, EAPTTLS, and EAP-TLS are supported for remote authentication servers. Local
(IAS) authentication supports EAP-MD5 only.
For information about configuring IEEE 802.1X settings, see "Configuring
Port and System Security" on page 481.

MAC-Based 802.1X Authentication
MAC-based authentication allows multiple supplicants connected to the
same port to each authenticate individually. For example, a system attached
to the port might be required to authenticate in order to gain access to the
network, while a VoIP phone might not need to authenticate in order to send
voice traffic through the port.
For information about configuring MAC-based 802.1X authentication, see
"Configuring Port and System Security" on page 481.
Switch Features

61

Dot1x Monitor Mode
Monitor mode can be enabled in conjunction with Dot1x authentication to
allow network access even when the user fails to authenticate. The switch logs
the results of the authentication process for diagnostic purposes. The main
purpose of this mode is to help troubleshoot the configuration of a Dot1x
authentication on the switch without affecting the network access to the
users of the switch.
For information about enabling the Dot1X Monitor mode, see "Configuring
Port and System Security" on page 481.

MAC-Based Port Security
The port security feature limits access on a port to users with specific MAC
addresses. These addresses are manually defined or learned on that port.
When a frame is seen on a locked port, and the frame source MAC address is
not tied to that port, the protection mechanism is invoked.
For information about configuring MAC-based port security, see "Configuring
Port and System Security" on page 481.

Access Control Lists (ACL)
Access Control Lists (ACLs) ensure that only authorized users have access to
specific resources while blocking off any unwarranted attempts to reach
network resources. ACLs are used to provide traffic flow control, restrict
contents of routing updates, decide which types of traffic are forwarded or
blocked, and above all provide security for the network. The switch supports
the following ACL types:
•

IPv4 ACLs

•

IPv6 ACLs

•

MAC ACLs

For all ACL types, you can apply the ACL rule when the packet enters or exits
the physical port, LAG, or VLAN interface.
For information about configuring ACLs, see "Configuring Access Control
Lists" on page 523.

62

Switch Features

Time-Based ACLs
With the Time-based ACL feature, you can define when an ACL is in effect
and the amount of time it is in effect.
For information about configuring time-based ACLs, see "Configuring Access
Control Lists" on page 523.

IP Source Guard (IPSG)
IP source guard (IPSG) is a security feature that filters IP packets based on
the source ID. The source ID may either be source IP address or a source IP
address source MAC address pair.
For information about configuring IPSG, see "Snooping and Inspecting
Traffic" on page 781.

DHCP Snooping
DHCP Snooping is a security feature that monitors DHCP messages between
a DHCP client and DHCP server. It filters harmful DHCP messages and
builds a bindings database of (MAC address, IP address, VLAN ID, port)
tuples that are specified as authorized. DHCP snooping can be enabled
globally and on specific VLANs. Ports within the VLAN can be configured to
be trusted or untrusted. DHCP servers must be reached through trusted ports.
For information about configuring DHCP Snooping, see "Snooping and
Inspecting Traffic" on page 781.

Dynamic ARP Inspection
Dynamic ARP Inspection (DAI) is a security feature that rejects invalid and
malicious ARP packets. The feature prevents a class of man-in-the-middle
attacks, where an unfriendly station intercepts traffic for other stations by
poisoning the ARP caches of its unsuspecting neighbors. The malicious
station sends ARP requests or responses mapping another station's IP address
to its own MAC address.
Dynamic ARP Inspection relies on DHCP Snooping.
For information about configuring DAI, see "Snooping and Inspecting Traffic"
on page 781.

Switch Features

63

Protected Ports (Private VLAN Edge)
Private VLAN Edge (PVE) ports are a Layer 2 security feature that provides
port-based security between ports that are members of the same VLAN. It is
an extension of the common VLAN. Traffic from protected ports is sent only
to the uplink ports and cannot be sent to other ports within the VLAN.
For information about configuring IPSG, see "Configuring Port-Based Traffic
Control" on page 687.

64

Switch Features

Green Technology Features
For information about configuring Green Technology features, see
"Configuring Port Characteristics" on page 457.

Energy Detect Mode
When the Energy Detect mode is enabled and the port link is down, the PHY
automatically goes down for short period of time and then wakes up to check
link pulses. This mode reduces power consumption on the port when no link
partner is present.

Energy Efficient Ethernet
The switch supports the IEEE 802.3az Energy Efficient Ethernet (EEE)
Lower Power Idle Mode, which enables both the send and receive sides of the
link to disable some functionality for power savings when the link is lightly
loaded.

Power Utilization Reporting
The switch displays the current power consumption of the power supply (or
power supplies). This information is available from the management
interface.

Switch Features

65

Power over Ethernet (PoE) Plus Features
NOTE: The PowerConnect 7024P and 7048P switches support PoE Plus. The PoE
Plus features do not apply to the other models in the PowerConnect 7000 Series.

For information about configuring PoE Plus features, see "Managing General
System Settings" on page 239."

Power Over Ethernet (PoE) Plus Configuration
The PowerConnect 7024P and 7048P switches support PoE Plus
configuration for power threshold, power priority, SNMP traps, and PoE
legacy device support. PoE can be administratively enabled or disabled on a
per-port basis. Power can also be limited on a per-port basis.

PoE Plus Support
The PowerConnect 7024P and 7048P switches implement the PoE Plus
specification (IEEE 802.3AT). This allows power to be supplied to Class 4 PD
devices that require power greater than 15.4 Watts. Each port is capable of
delivering up to 30W of power. Real-time power supply status is also available
on the switch as part of the PoE Plus implementation.

Switching Features
Flow Control Support (IEEE 802.3x)
Flow control enables lower speed switches to communicate with higher speed
switches by requesting that the higher speed switch refrains from sending
packets. Transmissions are temporarily halted to prevent buffer overflows.
For information about configuring flow control, see "Configuring Port-Based
Traffic Control" on page 687.

Head of Line Blocking Prevention
Head of Line (HOL) blocking prevention prevents traffic delays and frame
loss caused by traffic competing for the same egress port resources. HOL
blocking queues packets, and the packets at the head of the queue are
forwarded before packets at the end of the queue.
66

Switch Features

Jumbo Frames Support
Jumbo frames enable transporting data in fewer frames to ensure less
overhead, lower processing time, and fewer interrupts.
For information about configuring the port MTU, see "Configuring Port
Characteristics" on page 457.

Auto-MDI/MDIX Support
Your switch supports auto-detection between crossed and straight-through
cables. Media-Dependent Interface (MDI) is the standard wiring for end
stations, and the standard wiring for hubs and switches is known as MediaDependent Interface with Crossover (MDIX).

VLAN-Aware MAC-based Switching
Packets arriving from an unknown source address are sent to the CPU and
added to the Hardware Table. Future packets addressed to or from this
address are more efficiently forwarded.

Back Pressure Support
On half-duplex links, a receiver may prevent buffer overflows by jamming the
link so that it is unavailable for additional traffic. On full-duplex links, a
receiver may send a PAUSE frame indicating that the transmitter should
cease transmission of frames for a specified period.
When flow control is enabled, the PowerConnect 7000 Series switches will
observe received PAUSE frames or jamming signals, but will not issue them
when congested.

Switch Features

67

Auto Negotiation
Auto negotiation allows the switch to advertise modes of operation. The auto
negotiation function provides the means to exchange information between
two switches that share a point-to-point link segment, and to automatically
configure both switches to take maximum advantage of their transmission
capabilities.
PowerConnect 7000 Series switches enhance auto negotiation by providing
configuration of port advertisement. Port advertisement allows the system
administrator to configure the port speeds that are advertised.
For information about configuring auto negotiation, see "Configuring Port
Characteristics" on page 457.

Broadcast Storm Control
When Layer 2 frames are forwarded, broadcast, unknown unicast, and
multicast frames are flooded to all ports on the relevant virtual local area
network (VLAN). The flooding occupies bandwidth, and loads all nodes
connected on all ports. Storm control limits the amount of broadcast,
unknown unicast, and multicast frames accepted and forwarded by the
switch.
For information about configuring Broadcast Storm Control settings, see
"Configuring Port-Based Traffic Control" on page 687.

Port Mirroring
Port mirroring monitors and mirrors network traffic by forwarding copies of
incoming and outgoing packets from up to four source ports to a monitoring
port. The switch also supports flow-based mirroring, which allows you to copy
certain types of traffic to a single destination port. This provides flexibility—
instead of mirroring all ingress or egress traffic on a port the switch can mirror
a subset of that traffic. You can configure the switch to mirror flows based on
certain kinds of Layer 2, Layer 3, and Layer 4 information.
For information about configuring port mirroring, see "Monitoring Switch
Traffic" on page 363.

68

Switch Features

Static and Dynamic MAC Address Tables
You can add static entries to the switch’s MAC address table and configure
the aging time for entries in the dynamic MAC address table. You can also
search for entries in the dynamic table based on several different criteria.
For information about viewing and managing the MAC address table, see
"Managing the MAC Address Table" on page 837.

Link Layer Discovery Protocol (LLDP)
The IEEE 802.1AB defined standard, Link Layer Discovery Protocol (LLDP),
allows the switch to advertise major capabilities and physical descriptions.
This information can help you identify system topology and detect bad
configurations on the LAN.
For information about configuring LLDP, settings see "Discovering Network
Devices" on page 659.

Link Layer Discovery Protocol (LLDP) for Media Endpoint Devices
The Link Layer Discovery Protocol for Media Endpoint Devices (LLDPMED) provides an extension to the LLDP standard for network configuration
and policy, device location, Power over Ethernet management, and inventory
management.
For information about configuring LLDP-MED, settings see "Discovering
Network Devices" on page 659.

Connectivity Fault Management (IEEE 802.1ag)
The Connectivity Fault Management (CFM) feature, also known as Dot1ag,
supports Service Level Operations, Administration, and Management
(OAM). CFM is the OAM Protocol provision for end-to-end service layer
instance in carrier networks. The CFM feature provides mechanisms to help
you perform connectivity checks, fault detection, fault verification and
isolation, and fault notification per service in a network domain.
For information about configuring IEEE 802.1ag settings, see "Configuring
Connectivity Fault Management" on page 761.

Switch Features

69

switchCisco Protocol Filtering
The Cisco Protocol Filtering feature (also known as Link Local Protocol
Filtering) filters Cisco protocols that should not normally be relayed by a
bridge. The group addresses of these Cisco protocols do not fall within the
IEEE defined range of the 802.1D MAC Bridge Filtered MAC Group
Addresses (01-80-C2-00-00-00 to 01-80-C2-00-00-0F).
For information about configuring LLPF, settings see "Configuring PortBased Traffic Control" on page 687.

DHCP Layer 2 Relay
This feature permits Layer 3 Relay agent functionality in Layer 2 switched
networks. The switch supports L2 DHCP relay configuration on individual
ports, link aggregation groups (LAGs) and VLANs.
For information about configuring L2 DHCP Relay settings see "Configuring
L2 and L3 Relay Features" on page 907.

Virtual Local Area Network Supported Features
For information about configuring VLAN features see "Configuring VLANs"
on page 561.

VLAN Support
VLANs are collections of switching ports that comprise a single broadcast
domain. Packets are classified as belonging to a VLAN based on either the
VLAN tag or a combination of the ingress port and packet contents. Packets
sharing common attributes can be groups in the same VLAN. The
PowerConnect 7000 Series switches are in full compliance with IEEE 802.1Q
VLAN tagging.

Port-Based VLANs
Port-based VLANs classify incoming packets to VLANs based on their ingress
port. When a port uses 802.1X port authentication, packets can be assigned
to a VLAN based on the result of the 802.1X authentication a client uses
when it accesses the switch. This feature is useful for assigning traffic to
Guest VLANs or Voice VLANs.

70

Switch Features

IP Subnet-based VLAN
This feature allows incoming untagged packets to be assigned to a VLAN and
traffic class based on the source IP address of the packet.

MAC-based VLAN
This feature allows incoming untagged packets to be assigned to a VLAN and
traffic class based on the source MAC address of the packet.

IEEE 802.1v Protocol-Based VLANs
VLAN classification rules are defined on data-link layer (Layer 2) protocol
identification. Protocol-based VLANs are used for isolating Layer 2 traffic for
differing Layer 3 protocols.

GARP and GVRP Support
The switch supports the configuration of Generic Attribute Registration
Protocol (GARP) timers GARP VLAN Registration Protocol (GVRP) relies on
the services provided by GARP to provide IEEE 802.1Q-compliant VLAN
pruning and dynamic VLAN creation on 802.1Q trunk ports. When GVRP is
enabled, the switch registers and propagates VLAN membership on all ports
that are part of the active spanning tree protocol topology.
For information about configuring GARP timers see "Configuring L2
Multicast Features" on page 703.

Voice VLAN
The Voice VLAN feature enables switch ports to carry voice traffic with
defined priority. The priority level enables the separation of voice and data
traffic coming onto the port. Voice VLAN is the preferred solution for
enterprises wishing to deploy voice services in their network.

Switch Features

71

Guest VLAN
The Guest VLAN feature allows a switch to provide a distinguished service to
unauthenticated users. This feature provides a mechanism to allow visitors
and contractors to have network access to reach external network with no
ability to browse information on the internal LAN.
For information about configuring the Guest VLAN see "Configuring Port
and System Security" on page 481.

Double VLANs
The Double VLAN feature (IEEE 802.1QinQ) allows the use of a second tag
on network traffic. The additional tag helps differentiate between customers
in the Metropolitan Area Networks (MAN) while preserving individual
customer’s VLAN identification when they enter their own 802.1Q domain.

72

Switch Features

Spanning Tree Protocol Features
For information about configuring Spanning Tree Protocol features, see
"Configuring the Spanning Tree Protocol" on page 629.

Spanning Tree Protocol (STP)
Spanning Tree Protocol (IEEE 802.1D) is a standard requirement of Layer 2
switches that allows bridges to automatically prevent and resolve L2
forwarding loops.

Spanning Tree Port Settings
The STP feature supports a variety of per-port settings including path cost,
priority settings, Port Fast mode, STP Root Guard, Loop Guard, TCN Guard,
and Auto Edge. These settings are also configurable per-LAG.

Rapid Spanning Tree
Rapid Spanning Tree Protocol (RSTP) detects and uses network topologies to
enable faster spanning tree convergence after a topology change, without
creating forwarding loops. The port settings supported by STP are also
supported by RSTP.

Multiple Spanning Tree
Multiple Spanning Tree (MSTP) operation maps VLANs to spanning tree
instances. Packets assigned to various VLANs are transmitted along different
paths within MSTP Regions (MST Regions). Regions are one or more
interconnected MSTP bridges with identical MSTP settings. The MSTP
standard lets administrators assign VLAN traffic to unique paths.
The switch supports IEEE 802.1Q-2005, which is a version of corrects
problems associated with the previous version, provides for faster transitionto-forwarding, and incorporates new features for a port (restricted role and
restricted TCN).

Switch Features

73

Bridge Protocol Data Unit (BPDU) Guard
Spanning Tree BPDU Guard is used to disable the port in case a new device
tries to enter the already existing topology of STP. Thus devices, which were
originally not a part of STP, are not allowed to influence the STP topology.

BPDU Filtering
When spanning tree is disabled on a port, the BPDU Filtering feature allows
BPDU packets received on that port to be dropped. Additionally, the BPDU
Filtering feature prevents a port in Port Fast mode from sending and receiving
BPDUs. A port in Port Fast mode is automatically placed in the forwarding
state when the link is up to increase convergence time.

Link Aggregation Features
For information about configuring link aggregation (port-channel) features,
see "Configuring Link Aggregation" on page 819.

Link Aggregation
Up to eight ports can combine to form a single Link Aggregation Group
(LAG). This enables fault tolerance protection from physical link disruption,
higher bandwidth connections and improved bandwidth granularity.
Per IEEE 802.1AX, only links with the same operational characteristics, such
as speed and duplex setting, may be aggregated. PowerConnect switches
aggregate links only if they have the same operational speed and duplex
setting, as opposed to the configured speed and duplex setting. This allows
operators to aggregate links that use auto negotiation to set values for speed
and duplex. Dissimilar ports will not become active in the LAG if their
operational settings do not match those of the first member of the LAG.
PowerConnect switches also support setting the MTU on a LAG. When a link
becomes active in a LAG, its MTU is dynamically changed to the LAG MTU.
When the link leaves the LAG, its MTU reverts to the link setting.

Link Aggregate Control Protocol (LACP)
Link Aggregate Control Protocol (LACP) uses peer exchanges across links to
determine, on an ongoing basis, the aggregation capability of various links,
and continuously provides the maximum level of aggregation capability

74

Switch Features

achievable between a given pair of systems. LACP automatically determines,
configures, binds, and monitors the binding of ports to aggregators within the
system.

Switch Features

75

Routing Features
Address Resolution Protocol (ARP) Table Management
You can create static ARP entries and manage many settings for the dynamic
ARP table, such as age time for entries, retries, and cache size.
For information about managing the ARP table, see "Configuring IP Routing"
on page 883.

VLAN Routing
PowerConnect 7000 Series switches support VLAN routing. You can also
configure the software to allow traffic on a VLAN to be treated as if the VLAN
were a router port.
For information about configuring VLAN routing interfaces, see "Configuring
Routing Interfaces" on page 843.

IP Configuration
The switch IP configuration settings to allow you to configure network
information for VLAN routing interfaces such as IP address and subnet mask,
MTU size, and ICMP redirects. Global IP configuration settings for the
switch allow you to enable or disable the generation of several types of ICMP
messages and enable or disable the routing mode.
For information about managing global IP settings, see "Configuring IP
Routing" on page 883.

Open Shortest Path First (OSPF)
Open Shortest Path First (OSPF) is a dynamic routing protocol commonly
used within medium-to-large enterprise networks. OSPF is an interior
gateway protocol (IGP) that operates within a single autonomous system.
For information about configuring OSPF, see "Configuring OSPF and
OSPFv3" on page 931.

76

Switch Features

BOOTP/DHCP Relay Agent
The switch BootP/DHCP Relay Agent feature relays BootP and DHCP
messages between DHCP clients and DHCP servers that are located in
different IP subnets.
For information about configuring the BootP/DHCP Relay agent, see
"Configuring L2 and L3 Relay Features" on page 907.

IP Helper and UDP Relay
The IP Helper and UDP Relay features provide the ability to relay various
protocols to servers on a different subnet.
For information about configuring the IP helper and UDP relay features, see
"Configuring L2 and L3 Relay Features" on page 907.

Routing Information Protocol
Routing Information Protocol (RIP), like OSPF, is an IGP used within an
autonomous Internet system. RIP is an IGP that is designed to work with
moderate-size networks.
For information about configuring RIP, see "Configuring RIP" on page 1019.

Router Discovery
For each interface, you can configure the Router Discovery Protocol (RDP) to
transmit router advertisements. These advertisements inform hosts on the
local network about the presence of the router.
For information about configuring router discovery, see "Configuring IP
Routing" on page 883.

Routing Table
The routing table displays information about the routes that have been
dynamically learned. You can configure static and default routes and route
preferences. A separate table shows the routes that have been manually
configured.
For information about viewing the routing table, see "Configuring IP
Routing" on page 883.

Switch Features

77

Virtual Router Redundancy Protocol (VRRP)
VRRP provides hosts with redundant routers in the network topology without
any need for the hosts to reconfigure or know that there are multiple routers.
If the primary (master) router fails, a secondary router assumes control and
continues to use the virtual router IP (VRIP) address.
VRRP Route Interface Tracking extends the capability of VRRP to allow
tracking of specific route/interface IP states within the router that can alter
the priority level of a virtual router for a VRRP group.
For information about configuring VRRP settings, see "Configuring VRRP"
on page 1033.

Tunnel and Loopback Interfaces
PowerConnect 7000 Series switches support the creation, deletion, and
management of tunnel and loopback interfaces. Tunnel interfaces facilitate
the transition of IPv4 networks to IPv6 networks. A loopback interface is
always expected to be up, so you can configure a stable IP address that other
network devices use to contact or identify the switch.
For information about configuring tunnel and loopback interfaces, see
"Configuring Routing Interfaces" on page 843.

IPv6 Routing Features
IPv6 Configuration
The switch supports IPv6, the next generation of the Internet Protocol. You
can globally enable IPv6 on the switch and configure settings such as the IPv6
hop limit and ICMPv6 rate limit error interval. You can also control whether
IPv6 is enabled on a specific interface. The switch supports the configuration
of many per-interface IPv6 settings including the IPv6 prefix and prefix
length.
For information about configuring general IPv6 routing settings, see
"Configuring IPv6 Routing" on page 1057.

78

Switch Features

IPv6 Routes
Because IPv4 and IPv6 can coexist on a network, the router on such a network
needs to forward both traffic types. Given this coexistence, each switch
maintains a separate routing table for IPv6 routes. The switch can forward
IPv4 and IPv6 traffic over the same set of interfaces.
For information about configuring IPv6 routes, see "Configuring IPv6
Routing" on page 1057.

OSPFv3
OSPFv3 provides a routing protocol for IPv6 networking. OSPFv3 is a new
routing component based on the OSPF version 2 component. In dual stack
IPv6, you can configure and use both OSPF and OSPFv3 components.
For information about configuring OSPFv3, see "Configuring OSPF and
OSPFv3" on page 931.

DHCPv6
DHCPv6 incorporates the notion of the “stateless” server, where DHCPv6 is
not used for IP address assignment to a client, rather it only provides other
networking information such as DNS, Network Time Protocol (NTP), and/or
Session Initiation Protocol (SIP) information.
For information about configuring DHCPv6 settings, see "Configuring
DHCPv6 Server and Relay Settings" on page 1081.

Switch Features

79

Quality of Service (QoS) Features
NOTE: Some features that can affect QoS, such as ACLs and Voice VLAN, are
described in other sections within this chapter.

Differentiated Services (DiffServ)
The QoS Differentiated Services (DiffServ) feature allows traffic to be
classified into streams and given certain QoS treatment in accordance with
defined per-hop behaviors. PowerConnect 7000 Series switches support both
IPv4 and IPv6 packet classification.
For information about configuring DiffServ, see "Configuring Differentiated
Services" on page 1101.

Class Of Service (CoS)
The Class Of Service (CoS) queueing feature lets you directly configure
certain aspects of switch queuing. This provides the desired QoS behavior for
different types of network traffic when the complexities of DiffServ are not
required. CoS queue characteristics, such as minimum guaranteed
bandwidth and transmission rate shaping, are configurable at the queue (or
port) level.
For information about configuring CoS, see "Configuring Class-of-Service" on
page 1129.

Auto Voice over IP (VoIP)
This feature provides ease of use for the user in setting up VoIP for IP phones
on a switch. This is accomplished by enabling a VoIP profile that a user can
select on a per port basis.
For information about configuring Auto VoIP, see "Configuring Auto VoIP" on
page 1147.

80

Switch Features

Internet Small Computer System Interface (iSCSI) Optimization
The iSCSI Optimization feature helps network administrators track iSCSI
traffic between iSCSI initiator and target systems. This is accomplished by
monitoring, or snooping traffic to detect packets used by iSCSI stations in
establishing iSCSI sessions and connections. Data from these exchanges may
optionally be used to create classification rules to assign the traffic between
the stations to a configured traffic class. This affects how the packets in the
flow are queued and scheduled for egress on the destination port.
For information about configuring iSCSI settings, see "Configuring iSCSI
Optimization" on page 403.

Layer 2 Multicast Features
For information about configuring L2 multicast features, see "Configuring L2
Multicast Features" on page 703.

MAC Multicast Support
Multicast service is a limited broadcast service that allows one-to-many and
many-to-many connections. In Layer 2 multicast services, a single frame
addressed to a specific multicast address is received, and copies of the frame
to be transmitted on each relevant port are created.

IGMP Snooping
Internet Group Management Protocol (IGMP) Snooping is a feature that
allows a switch to forward multicast traffic intelligently on the switch.
Multicast traffic is traffic that is destined to a host group. Host groups are
identified by the destination MAC address, i.e. the range 01:00:5e:00:00:00 to
01:00:5e:7f:ff:ff:ff for IPv4 multicast traffic or 33:33:xx:xx:xx:xx for IPv6
multicast traffic. Based on the IGMP query and report messages, the switch
forwards traffic only to the ports that request the multicast traffic. This
prevents the switch from broadcasting the traffic to all ports and possibly
affecting network performance.

Switch Features

81

IGMP Snooping Querier
When Protocol Independent Multicast (PIM) and IGMP are enabled in a
network with IP multicast routing, the IP multicast router acts as the IGMP
querier. However, if it is desirable to keep the multicast network Layer 2
switched only, the IGMP Snooping Querier can perform the query functions
of a Layer 3 multicast router.

MLD Snooping
In IPv4, Layer 2 switches can use IGMP Snooping to limit the flooding of
multicast traffic by dynamically configuring Layer 2 interfaces so that
multicast traffic is forwarded to only those interfaces associated with IP
multicast address.
In IPv6, MLD snooping performs a similar function. With MLD snooping,
IPv6 multicast data is selectively forwarded to a list of ports intended to
receive the data (instead of being flooded to all of the ports in a VLAN). This
list is constructed by snooping IPv6 multicast control packets.

Multicast VLAN Registration
The Multicast VLAN Registration (MVR) protocol, like IGMP Snooping,
allows a Layer 2 switch to listen to IGMP frames and forward the multicast
traffic only to the receivers that request it. Unlike IGMP Snooping, MVR
allows the switch to listen across different VLANs. MVR uses a dedicated
VLAN, which is called the multicast VLAN, to forward multicast traffic over
the Layer 2 network to the various VLANs that have multicast receivers as
members.

82

Switch Features

Layer 3 Multicast Features
For information about configuring L3 multicast features, see "Managing IPv4
and IPv6 Multicast" on page 1153.

Distance Vector Multicast Routing Protocol
Distance Vector Multicast Routing Protocol (DVMRP) exchanges probe
packets with all DVMRP-enabled routers, establishing two way neighboring
relationships and building a neighbor table. It exchanges report packets and
creates a unicast topology table, which is used to build the multicast routing
table. This multicast route table is then used to route the multicast packets.

Internet Group Management Protocol
The Internet Group Management Protocol (IGMP) is used by IPv4 systems
(hosts and routers) to report their IP multicast group memberships to any
neighboring multicast routers. PowerConnect 7000 Series switches perform
the “multicast router part” of the IGMP protocol, which means it collects the
membership information needed by the active multicast router.

IGMP Proxy
The IGMP Proxy feature allows the switch to act as a proxy for hosts by
sending IGMP host messages on behalf of the hosts that the switch
discovered through standard IGMP router interfaces.

Protocol Independent Multicast—Dense Mode
Protocol Independent Multicast (PIM) is a standard multicast routing
protocol that provides scalable inter-domain multicast routing across the
Internet, independent of the mechanisms provided by any particular unicast
routing protocol. The Protocol Independent Multicast-Dense Mode (PIMDM) protocol uses an existing Unicast routing table and a Join/Prune/Graft
mechanism to build a tree. PIM-DM creates source-based shortest-path
distribution trees, making use of reverse path forwarding (RPF).

Switch Features

83

Protocol Independent Multicast—Sparse Mode
Protocol Independent Multicast-Sparse Mode (PIM-SM) is used to efficiently
route multicast traffic to multicast groups that may span wide area networks,
and where bandwidth is a constraint. PIM-SM uses shared trees by default
and implements source-based trees for efficiency. This data threshold rate is
used to toggle between trees.

Protocol Independent Multicast—Source Specific Multicast
Protocol Independent Multicast—Source Specific Multicast (PIM-SSM) is a
subset of PIM-SM and is used for one-to-many multicast routing
applications, such as audio or video broadcasts. PIM-SSM does not use shared
trees.

Protocol Independent Multicast IPv6 Support
PIM-DM and PIM-SM support IPv6 routes.

MLD/MLDv2 (RFC2710/RFC3810)
MLD is used by IPv6 systems (listeners and routers) to report their IP
multicast addresses memberships to any neighboring multicast routers. The
implementation of MLD v2 is backward compatible with MLD v1.
MLD protocol enables the IPv6 router to discover the presence of multicast
listeners, the nodes that want to receive the multicast data packets, on its
directly attached interfaces. The protocol specifically discovers which
multicast addresses are of interest to its neighboring nodes and provides this
information to the multicast routing protocol that make the decision on the
flow of the multicast data packets.

84

Switch Features

3

Hardware Overview

This section provides an overview of the switch hardware. The topics covered
in this section include:
•

PowerConnect 7000 Series Front Panel

•

PowerConnect 7000 Series Back Panel

•

LED Definitions

•

Switch Addresses

PowerConnect 7000 Series Front Panel
The PowerConnect 7000 Series front panel includes the following features:
•

Switch Ports

•

Console Port

•

Out-of-Band Management Port

•

USB Port

•

Reset Button

•

Port and System LEDs

•

Stack Master LED and Stack Number Display

Hardware Overview

85

The following images show the front panels of the switch models in the
PowerConnect 7000 Series.
Figure 3-1. PowerConnect 7024 Front Panel with 24 10/100/1000Base-T Ports

10/100/1000Base-T Auto-sensing
Full Duplex RJ-45 Ports

Combo Ports

Figure 3-2. PowerConnect 7024P Front Panel with 24 10/100/1000Base-T PoE Plus Ports

10/100/1000Base-T RJ-45 PoE Plus Ports
Providing up to 30W per Port

Combo Ports

Figure 3-3. PowerConnect 7024F Front Panel with 24 SFP Ports

SFP Ports

86

Hardware Overview

Combo Ports

Figure 3-4. PowerConnect 7048 Front Panel with 48 10/100/1000Base-T Ports

10/100/1000Base-T Auto-sensing
Full Duplex RJ-45 Ports

Combo Ports

Figure 3-5. PowerConnect 7048P Front Panel with 48 10/100/1000Base-T PoE Plus Ports

10/100/1000Base-T RJ-45 PoE Plus Ports
Providing up to 30W per Port

Combo Ports

Figure 3-6. PowerConnect 7048R Front Panel with 48 10/100/1000Base-T Ports

10/100/1000Base-T Auto-sensing
Full Duplex RJ-45 Ports

Combo Ports

Hardware Overview

87

Figure 3-7 shows a detailed image of the front panel system ports and LEDs.
For more information about LED color and activity meaning, see "LED
Definitions" on page 95.
Figure 3-7. Front Panel System Ports and LEDs

Console Port

Out-of-Band
Management Port

System LEDs

USB Port

Reset Button

Switch Ports
The PowerConnect 7024 and PowerConnect 7024P front panels provide 24
Gigabit Ethernet (10/100/1000Base-T) RJ-45 ports with four SFP combo ports
that have an auto-sensing mode for speed, flow control, and duplex mode.
SFP transceivers are sold separately. The PowerConnect 7024P switch ports
are IEEE 802.3at-2009-compliant (PoE Plus) and can provided up to 30W of
power per port.
The PowerConnect 7024F front panel provides 20 Gigabit Ethernet
(10/100/1000BASE-FX) SFP ports plus 4 combo ports for copper or SFP
media support.
The PowerConnect 7048, PowerConnect 7048P, and PowerConnect 7048R
front panel provides 48 Gigabit Ethernet (10/100/1000Base-T) RJ-45 ports
with four SFP combo ports. The PowerConnect 7048P switch ports are IEEE
802.3at-2009-compliant (PoE Plus) and can provided up to 30W of power per
port.

88

Hardware Overview

The front-panel switch ports have the following characteristics:
•

The switch automatically detects the difference between crossed and
straight-through cables on RJ-45 ports.

•

SFP ports support both SX and LX modules.

•

RJ-45 ports support half- and full-duplex mode 10/100/1000 Mbps.

Console Port
The console port is for management through a serial interface. This port
provides a direct connection to the switch and allows you to access the CLI
from a console terminal connected to the port through the provided serial
cable (RJ-45 to female DB-9 connectors).
The console port supports asynchronous data of eight data bits, one stop bit, no
parity bit, and no flow control. The default baud rate is 9600 bps.

Out-of-Band Management Port
The Out-of-Band (OOB) management port is a 10/100/1000BASE-T
Ethernet port dedicated to remote switch management. Traffic on this port is
segregated from operational network traffic on the switch ports and cannot be
switched or routed to the operational network.

USB Port
The Type-A, female USB port supports a USB 2.0-compliant flash memory
drive. The PowerConnect switch can read or write to a flash drive formatted
as FAT-32. You can use a USB flash drive to copy switch configuration files
and images between the USB flash drive and the switch. You can also use the
USB flash drive to move and copy configuration files and images from one
switch to other switches in the network.
The USB port does not support any other type of USB device.

Hardware Overview

89

Reset Button
The reset button is accessed through the pinhole and allows you to perform a
hard reset on the switch. To use the reset button, insert an unbent paper clip
or similar tool into the pinhole. When the switch completes the boot process
after the reset, it resumes operation with the most recently saved
configuration. Any changes made to the running configuration that were not
saved to the startup configuration prior to the reset are lost.

Port and System LEDs
The front panel contains light emitting diodes (LEDs) that indicate the
status of port links, power supplies, fans, stacking, and the overall system.
Additionally, the PowerConnect 7024P and PowerConnect 7048P switches
contain LEDs that provide information about Power over Ethernet Plus
(PoE+) status and activity on the ports.
For information about the status that the LEDs indicate, see "LED
Definitions" on page 95.

Stack Master LED and Stack Number Display
When a switch within a stack is the stack master, the stack master LED,
which is labeled M, is solid green. If the M LED is off, the stack member is
not the stack master. The Stack No. panel displays the unit number for the
stack member. If a switch is not part of a stack, the M LED is illuminated and
the stack unit number is 1.

PowerConnect 7000 Series Back Panel
The PowerConnect 7000 Series back panel has the following features:

90

•

Expansion Slots for Plug-in Modules

•

Power Supplies

•

Ventilation System

•

Locator LED

Hardware Overview

The following images show the back panel of the PowerConnect 7000 Series
switches.
Figure 3-8. PC7024, PC7024F, and PC7048 Back Panel
Fan Vents

Redundant DC Power
Supply Receptacle

Dual 10G Slots for SFP+, 10GBase-T,
or Stacking/10GbE Modules

AC Power
Receptacle

Figure 3-9. PC7024P and PC7048P Back Panel
Fan Vents

Dual 10G Slots for SFP+, 10GBase-T,
or Stacking/10 GbE Modules
Figure 3-10.

External DC Power
Supply Receptacle

AC Power
Receptacle

PC7048R Back Panel
Fan Trays

AC Power
Receptacle

Dual 10G Slots for SFP+, 10GBase-T,
or Stacking/10GbE Modules

AC Power
Receptacle

Hardware Overview

91

Expansion Slots for Plug-in Modules
Two expansion slots are located on the back of the switch and can support the
following modules:
•

10GBase-T module

•

SFP+ module

•

Stacking/10 GbE module

Each plug-in module has two ports. The Stacking/10GbE modules can be
configured to operate as either 16-Gigabit stacking ports or 10-Gigabit
Ethernet switch ports. The plug-in modules include hot-swap support, so you
do not need to reboot the switch after you install a new module.
The following figures show the modules available for the PowerConnect 7000
Series switches.
Figure 3-11. 10GBase-T Module

Figure 3-12. SFP+ Module

Figure 3-13. Stacking/10 GbE Module

92

Hardware Overview

Power Supplies
PC7024 and PC7024F

PowerConnect 7024 and PowerConnect 7024F switches have an internal
180-watt power supply. The additional external power supply (PowerConnect
RPS720) provides 180 watts of power and gives full redundancy for the
switch.
PC7024P

PowerConnect 7024P switches have an internal 1000-watt power supply. The
additional external power supply (PowerConnect MPS1000) provides 1000
Watts and gives full redundancy for the switch.
PC7048

PowerConnect 7048 switches have an internal 180-watt power supply. The
additional external power supply (PowerConnect RPS720) provides 180 watts
and gives full redundancy for the switch.
PC7048P

PowerConnect 7048P switches have an internal 1000-watt power supply
which can support up to 24 ports of PoE. The additional external power
supply (PowerConnect MPS1000) allows all 48 ports of PoE, or 24 ports of
PoE and full redundancy for the switch.
PC7048R and PC7048R-RA

PowerConnect 7048R and PowerConnect 7048R-RA switches are designed as
top-of-rack switches and include two internal, replaceable, AC power supplies
for redundant or load-sharing operation. Each power supply can provide 300
watts and includes hot-swap support. This means you do not need to powerdown the switch to remove or replace one power supply while the other power
supply is operating normally. However, it is necessary to remove power from
the power supply that is being removed or replaced.
CAUTION: Remove the power cable from the modules prior to removing the
module itself. Power must not be connected prior to insertion in the chassis.

Hardware Overview

93

Ventilation System
Three fans cool the PowerConnect 7024, PowerConnect 7024F, and
PowerConnect 7048. The PowerConnect 7024P and PowerConnect 7048P
each have two fans, with a third fan in the internal power supply. The
PowerConnect 7048R has two hot-swappable fan trays with one fan each.

Locator LED
The back panel includes an LED to help identify the switch within a rack or
room full of switches. From your remote management system, you can set the
LED to blink to help you or a local technician identify the physical location of
the switch. For information about how to enable the switch locator feature,
see "Using the Device View Switch Locator Feature" on page 108.

94

Hardware Overview

LED Definitions
This section describes the LEDs on the front panel of the switch and on the
optional modules that plug into the back panel.

Port LEDs
Each port on a PowerConnect 7000 Series switch includes two LEDs. One
LED is on the left side of the port, and the second LED is on the right side of
the port. This section describes the LEDs on the switch ports, Out-of-Band
(OOB) management port, and console port.
100/1000/10000Base-T Port LEDs (PC7024, PC7024F, PC7048, PC7048R)

Table 3-1 contains the 100/1000/10000Base-T port LED definitions for the
PowerConnect 7024, PowerConnect 7048, and PowerConnect 7048R, as well
as the PowerConnect 7024F Combo ports.
Table 3-1.

100/1000/10000Base-T Port LED Definitions (Non-PoE Plus Models)

LED

Color/Activity

Definition

Left

Green

The port is operating at 1000 Mbps.

Yellow

The port is operating at 10/100 Mbps.

Solid

A link is present.

Off

No link is present.

Green blinking

The port is active.

Off

The port has no activity.

Right

100/1000/10000Base-T Port LEDs (PC7024P and PC7048P)

The 100/1000/10000Base-T ports on the PowerConnect 7024P and
PowerConnect 7048P include Power over Ethernet Plus support, and each
port is capable of delivering up to 30W of power to the connected PoEpowered device.
Table 3-2 contains the 100/1000/10000Base-T port LED definitions for the
PowerConnect 7024P and PowerConnect 7048P.

Hardware Overview

95

Table 3-2.

100/1000/10000Base-T Port LED Definitions (PC7024P and PC7048P)

LED

Color/Activity

Definition

Left

Green

The port is operating at 1000 Mbps.

Yellow

The port is operating at 10/100 Mbps.

Solid

A link is present.

Off

No link is present.

Green blinking

The port is active, and PoE Plus power is off.

Yellow blinking

The port is active, and PoE Plus power is on.

Yellow solid

The port has no activity, and PoE Plus power is on.

Off

The port has no activity, and PoE Plus power is off.

Right

SFP Port LEDs

Table 3-3 contains SFP port LED definitions for the PowerConnect 7000
Series switches.
Table 3-3.

SFP+ Port LED Definitions

LED

Color/Activity

Definition

Left

Green

The port is operating at 1000 Mbps.

Yellow

The port is operating at 10/100 Mbps.

Solid

A link is present.

Off

No link is present.

Green blinking

The port is active.

Off

The port has no activity.

Right

96

Hardware Overview

Module LEDs
The 10GBase-T module has two LEDs per port, the SFP+ module has one
LED per port, and the Stacking/10 GbE module does not have any LEDs.
10 Gigabit Ethernet Port LEDs

Table 3-4 contains LED definitions for 10 GbE ports on the plug-in module
available for PowerConnect 7000 Series switches.
Table 3-4.

10 GbE Port LEDs Definitions

LED

Color/Activity

Definition

LNK (Left)

Green solid

The port is linked at 10G.

Yellow solid

The port is linked at another speed.

Off

The port is not linked.

Green blinking

The port is sending and/or receiving network
traffic.

Off

The port has no activity.

ACT (Right)

SFP+ Port LEDs

Table 3-5 contains LED definitions for SFP+ port on the plug-in module
available for PowerConnect 7000 Series switches.
Table 3-5.

SFP+ Port LEDs Definitions

LED

Color/Activity

Definition

LNK/ACT

Green solid

The port is linked.

Green blinking

The port is sending and/or receiving network
traffic.

Off

The port is not linked.

Hardware Overview

97

Console Port LEDs

The console port is labeled with the |O|O| symbol and is for management
through a serial interface. This port provides a direct connection to the switch
and allows you to access the CLI from a console terminal connected to the
port through the provided serial cable (RJ-45 to female DB-9 connectors).
Table 3-6 contains the console port LED definitions for the PowerConnect
7000 Series switches.
Table 3-6.

Console Port LED Definitions

LED

Color/Activity

Definition

Left

Solid Green

A link is present.

Off

No link is present.

Out-of-Band Management Port LEDs

The OOB port is a 100/1000/10000Base-T port that is dedicated to remote
switch management. The OOB port is labeled with the
symbol and is to
the right of the console port. Traffic on this port is segregated from
operational network traffic on the switch ports and cannot be switched or
routed to the operational network.
Table 3-7 contains the OOB port LED definitions for the PowerConnect 7000
Series switches.
Table 3-7.

OOB Management Port LED Definitions

LED

Color/Activity

Definition

Left

Green

The port is operating at 1000 Mbps.

Yellow

The port is operating at 10/100 Mbps.

Solid

A link is present.

Off

No link is present.

Green blinking

The port is active.

Off

The port has no activity.

Right

98

Hardware Overview

System LEDs
The system LEDs for the PowerConnect 7000 Series switches are located on
the right side of the front panel. The system LEDs indicate whether the
switch is the stack master and provide information about the status of system
diagnostics, switch temperature and power.
The system LEDs on the front panel of the switch depend on the switch
model. Figure 3-14 shows the LEDs available on each model in the
PowerConnect 7000 Series.
Figure 3-14.

System LEDs

us
at
St
R1
PW

PC7024
PC7024F
PC7048

us
at
St

MPS Fan

EPS Fan

M PWR2 Fan

R
PW

us
at
St

R
PW

M

M

PC7048R

PC7024P
PC7048P

Table 3-8 contains the System LED definitions.
Table 3-8.

System LED Definitions

LED

Color

Definition

Status

Green solid

Switch is operating normally.

Green blinking Booting, and the diagnostics test is in progress.
Red solid
FAN

Critical system error detected.

Red blinking

Non-critical system error detected.

Green solid

Fans are operating normally.

Red solid

One or more fans have failed.

Hardware Overview

99

Table 3-8.

System LED Definitions (Continued)

LED

Color

Definition

PWRa

Green solid

Power Supply is operating normally.

Green blinking Switch locator function activated.
RPS

EPS

M

Off

Power is off or has failed.

Green solid

Redundant power supply is operating normally.

Red solid

A redundant power supply is detected, but it is not
operating correctly.

Off

No redundant power supply is detected.

Green solid

External power supply is operating normally.

Red solid

An external power supply is detected, but it is not
operating correctly.

Off

No external power supply is detected.

Green solid

Master switch for the stack. A standalone switch is
always the master.

Off

Non-master stack unit.

a. The PowerConnect 7048R has two power supplies. The PWR1 LED indicates the status of the
first power supply, and the PWR2 LEDs indicates the status of the second power supply.

Switch Addresses
The switch allocates MAC addresses from the Vital Product Data information
stored locally in flash. MAC addresses are used as follows:
Table 3-9.

MAC Address Use

Base

switch address

Base + 1

Out-of-band port

Base + 2

Layer 2

Base + 3

Layer 3

100

Hardware Overview

Shown below are three commands that display the MAC addresses used by
the switch:
console#show system
System Description: Dell Ethernet Switch
System Up Time: 0 days, 00h:05m:11s
System Contact:
System Name:
System Location:
Burned In MAC Address: 001E.C9F0.004D
System Object ID: 1.3.6.1.4.1.674.10895.3042
System Model ID: PCT8132
Machine Type: PowerConnect 8132
Temperature Sensors:
Unit

Description

---1
1
1
1

----------MAC
CPU
PHY (left side)
PHY (right side)

Temperature
(Celsius)
----------32
31
26
29

Status
-----Good
Good
Good
Good

Fans:
Unit
---1
1
1
1
1
1

Description
----------Fan 1
Fan 2
Fan 3
Fan 4
Fan 5
Fan 6

Status
-----OK
OK
OK
OK
OK
No Power

Power Supplies:
Unit

Description

---1
1
1

----------System
Main
Secondary

Status

----------OK
OK
No Power

Average
Power
(Watts)
---------42.0
N/A
N/A

Current
Power
(Watts)
-------43.4
N/A
N/A

Since
Date/Time
------------------04/06/2001 16:36:16
01/01/1970 00:00:00

USB Port Power Status:
---------------------Device Not Present

Hardware Overview

101

console#show ip interface out-of-band
IP Address.....................................
Subnet Mask....................................
Default Gateway................................
Configured IPv4 Protocol.......................
Burned In MAC Address..........................

10.27.21.29
255.255.252.0
10.27.20.1
DHCP
001E.C9F0.004E

console#show ip interface vlan 1
Routing Interface Status.......................
Primary IP Address.............................
Method.........................................
Routing Mode...................................
Administrative Mode............................
Forward Net Directed Broadcasts................
Proxy ARP......................................
Local Proxy ARP................................
Active State...................................
MAC Address....................................
Encapsulation Type.............................
IP MTU.........................................
Bandwidth......................................
Destination Unreachables.......................
ICMP Redirects.................................

102

Hardware Overview

Down
1.1.1.2/255.255.255.0
Manual
Enable
Enable
Disable
Enable
Disable
Inactive
001E.C9F0.0050
Ethernet
1500
10000 kbps
Enabled
Enabled

Using Dell OpenManage Switch
Administrator

4

This section describes how to use the Dell OpenManage Switch
Administrator application. The topics covered in this section include:
•

About Dell OpenManage Switch Administrator

•

Starting the Application

•

Understanding the Interface

•

Using the Switch Administrator Buttons and Links

•

Defining Fields

About Dell OpenManage Switch Administrator
Dell OpenManage Switch Administrator is a web-based tool to help you
manage and monitor a PowerConnect 7000 Series switch. Table 4-1 lists the
web browsers that are compatible with Dell OpenManage Switch
Administrator. The browsers have been tested on a PC running the Microsoft
Windows operating system.
Table 4-1.

Compatible Browsers

Browser

Version

Internet Explorer

v9

Mozilla Firefox

v14

Safari

v5.0

Chrome

v21

NOTE: Additional operating systems and browsers might be compatible but have
not been explicitly tested with Dell OpenManage Switch Administrator.

Using Dell OpenManage Switch Administrator

103

Starting the Application
To access the Dell OpenManage Switch Administrator and log on to the
switch:
1 Open a web browser.
2 Enter the IP address of the switch in the address bar and press .
For information about assigning an IP address to a switch, see "Setting the
IP Address and Other Basic Network Information" on page 121.
3 When the Login window displays, enter a user name and password.
Passwords are both case sensitive and alpha-numeric.
Figure 4-1. Login Screen

NOTE: The switch is not configured with a default user name or password.
You must connect to the CLI by using the console port to configure the initial
user name and password. For information about connecting to the console,
see "Console Connection" on page 109. For information about creating a user
and password, see "Configuring Authentication, Authorization, and
Accounting" on page 175.
4 Click Submit.
104

Using Dell OpenManage Switch Administrator

5 The Dell OpenManage Switch Administrator home page displays.
The home page is the Device Information page, which contains a
graphical representation of the front panel of the switch. For more
information about the home page, see "Device Information" on page 207.

Understanding the Interface
The Dell OpenManage Switch Administrator interface contains the following
components:
•

Navigation panel — Located on the left side of the page, the navigation
pane provides an expandable view of features and their components.

•

Configuration and status options — The main panel contains the fields
you use to configure and monitor the switch.

•

Page tabs — Some pages contain tabs that allow you to access additional
pages related to the feature.

•

Command buttons — Command buttons are located at the bottom of the
page. Use the command buttons to submit changes, perform queries, or
clear lists.

•

Save, Print, Refresh, and Help buttons — These buttons appear on the
top-right side of the main panel and are on every page.

•

Support, About, and Logout links — These links appear at the top of every
page.

Using Dell OpenManage Switch Administrator

105

Figure 4-2. Switch Administrator Components
Navigation Panel

Page Tabs

Links

Save, Print, Refresh, Help

Configuration and Status Options

Command Button

Using the Switch Administrator Buttons and Links
Table 4-2 describes the buttons and links available from the Dell
OpenManage Switch Administrator interface.
Table 4-2.

Button and Link Descriptions

Button or Link

Description

Support

Opens the Dell Support page at support.dell.com

About

Contains the version and build number and Dell copyright
information.

Log Out

Logs out of the application and returns to the login screen.

Save

Saves the running configuration to the startup configuration.
When you click Apply, changes are saved to the running
configuration. When the system boots, it loads the startup
configuration. Any changes to the running configuration that were
not saved to the startup configuration are lost across a power cycle.

106

Using Dell OpenManage Switch Administrator

Table 4-2.

Button and Link Descriptions (Continued)

Button or Link

Description

Print

Opens the printer dialog box that allows you to print the current
page. Only the main panel prints.

Refresh

Refreshes the screen with the current information.

Help

Online help that contains information to assist in configuring and
managing the switch. The online help pages are context sensitive.
For example, if the IP Addressing page is open, the help topic for
that page displays if you click Help.

Apply

Updates the running configuration on the switch with the changes.
Configuration changes take effect immediately.

Clear

Resets statistic counters and log files to the default configuration.

Query

Queries tables.

Left arrow and
Right arrow

Moves information between lists.

NOTE: A few pages contain a button that occurs only on that page. Page-specific
buttons are described in the sections that pertain to those pages.

Defining Fields
User-defined fields can contain 1–159 characters, unless otherwise noted on
the Dell OpenManage Switch Administrator web page.
All characters may be used except for the following:
•

\

•

/

•

:

•

*

•

?

•

<

•

>

•

|
Using Dell OpenManage Switch Administrator

107

Understanding the Device View
The Device View shows various information about switch. This graphic
appears on the OpenManage Switch Administrator Home page, which is the
page that displays after a successful login. The graphic provides information
about switch ports and system health.
Figure 4-3. PowerConnect 7024 Device View

Using the Device View Port Features
The switching-port coloring indicates if a port is currently active. Green
indicates that the port has a link, red indicates that an error has occurred on
the port, and blue indicates that the link is down. Each port image is a
hyperlink to the Port Configuration page for the specific port.

Using the Device View Switch Locator Feature
The Device View graphic includes a Locate button and a drop-down menu of
timer settings. When you click Locate, the switch locator LED on the back
panel of the switch blinks for the number of seconds selected from the timer
menu. The green, blinking LED on the back of the switch can help you or a
technician near the switch identify the physical location of the switch within
a room or rack full of switches. After you click the Locate button it turns
green and remains green while the LED is blinking. For more information
about the locator LED, see "Locator LED" on page 94.
NOTE: You can also issue the locate command from the CLI to enable the locator

LED.

108

Using Dell OpenManage Switch Administrator

5

Using the Command-Line Interface

This section describes how to use the Command-Line Interface (CLI) on a
PowerConnect 7000 Series switch.
The topics covered in this section include:
•

Accessing the Switch Through the CLI

•

Understanding Command Modes

•

Entering CLI Commands

Accessing the Switch Through the CLI
The CLI provides a text-based way to manage and monitor the
PowerConnect 7000 Series switch. You can access the CLI by using a direct
connection to the console port or by using a Telnet or SSH client.
To access the switch by using Telnet or Secure Shell (SSH), the switch must
have an IP address, and the management station you use to access the device
must be able to ping the switch IP address.
For information about assigning an IP address to a switch, see "Setting the IP
Address and Other Basic Network Information" on page 121.

Console Connection
Use the following procedures to connect to the CLI by connecting to the
console port. For more information about creating a serial connection, see the
Getting Started Guide available at support.dell.com/manuals.
1 Connect the DB-9 connector of the supplied serial cable to a management
station, and connect the RJ-45 connector to the switch console port.
The console port is located on the right side of the front panel and is labeled
with the |O|O| symbol.
NOTE: For a stack of switches, be sure to connect to the console port on the
Master switch. The Master LED (M) is illuminated on the stack Master.

Using the Command-Line Interface

109

2 Start the terminal emulator, such as Microsoft HyperTerminal, and select
the appropriate serial port (for example, COM 1) to connect to the
console.
3 Configure the management station serial port with the following settings:
•

Data rate — 9600 baud.

•

Data format — 8 data bits

•

Parity — None

•

Stop bits — 1

•

Flow control — None

4 Power on the switch (or stack).
After the boot process completes, the console> prompt displays, and
you can enter commands.
NOTE: By default, no authentication is required for console access.
However, if an authentication method has been configured for console port
access, the User: login prompt displays.

Telnet Connection
Telnet is a terminal emulation TCP/IP protocol. ASCII terminals can be
virtually connected to the local device through a TCP/IP protocol network.
Telnet connections are enabled by default, and the Telnet port number is 23.
The switch supports up to four simultaneous Telnet sessions. All CLI
commands can be used over a Telnet session.
NOTE: SSH, which is more secure than Telnet, is disabled by default.
To connect to the switch using Telnet, the switch must have an IP address,
and the switch and management station must have network connectivity. You
can use any Telnet client on the management station to connect to the
switch.
You can also initiate a Telnet session from the OpenManage Switch
Administrator. For more information, see "Initiating a Telnet Session from the
Web Interface" on page 247.

110

Using the Command-Line Interface

Understanding Command Modes
The CLI groups commands into modes according to the command function.
Each of the command modes supports specific software commands. The
commands in one mode are not available until you switch to that particular
mode, with the exception of the User EXEC mode commands. You can
execute the User EXEC mode commands in the Privileged EXEC mode.
To display the commands available in the current mode, enter a question
mark (?) at the command prompt. In each mode, a specific command is used
to navigate from one command mode to another.
The main command modes include the following:
•

User EXEC — Commands in this mode permit connecting to remote
devices, changing terminal settings on a temporary basis, performing basic
tests, and listing system information.

•

Privileged EXEC — Commands in this mode permit you to view all switch
settings and to enter the global configuration mode.

•

Global Configuration — Commands in this mode manage the device
configuration on a global level and apply to system features, rather than to
a specific protocol or interface.

•

Interface Configuration — Commands in this mode configure the settings
for a specific interface or range of interfaces.

•

VLAN Configuration — Commands in this mode create and remove
VLANs and configure IGMP/MLD Snooping parameters for VLANs.

The CLI includes several additional command modes. For more information
about the CLI command modes, including details about all modes, see the
CLI Reference Guide.
Table 5-1 describes how to navigate between CLI Command Mode and lists
the prompt that displays in each mode.

Using the Command-Line Interface

111

Table 5-1.

Command Mode Overview

Command Mode

Access Method

Command Prompt

User EXEC

The user is
console>
automatically in
User EXEC
mode unless the
user is defined as
a privileged user.

Exit or Access
Previous Mode
logout

Privileged EXEC From User
console#
EXEC mode,
enter the enable
command

Use the exit
command, or press
Ctrl-Z to return to
User EXEC mode.

Global
Configuration

From Privileged console(config)#
EXEC mode, use
the configure
command.

Use the exit
command, or press
Ctrl-Z to return to
Privileged EXEC
mode.

Interface
Configuration

From Global
Configuration
mode, use the
interface
command and
specify the
interface type
and ID.

To exit to Global
Configuration
mode, use the exit
command, or press
Ctrl-Z to return to
Privileged EXEC
mode.

112

console(configif)#

Using the Command-Line Interface

Entering CLI Commands
The switch CLI uses several techniques to help you enter commands.

Using the Question Mark to Get Help
Enter a question mark (?) at the command prompt to display the commands
available in the current mode.
console(config-vlan)#?
exit
help
ip
ipv6
protocol
vlan

To exit from the mode.
Display help for various special keys.
Configure IP parameters.
Configure IPv6 parameters.
Configure the Protocols associated with
particular Group Ids.
Create a new VLAN or delete an existing
VLAN.

Enter a question mark (?) after each word you enter to display available
command keywords or parameters.
console(config)#vlan ?
database
protocol

Type 'vlan database' to enter VLAN mode.
Configure Protocol Based VLAN parameters.

If the help output shows a parameter in angle brackets, you must replace the
parameter with a value.
console#telnet ?


Enter the valid host IP
address or Host Name.

If there are no additional command keywords or parameters, or if additional
parameters are optional, the following message appears in the output:


Press enter to execute the command.
Using the Command-Line Interface

113

You can also enter a question mark (?) after typing one or more characters of a
word to list the available command or parameters that begin with the letters,
as shown in the following example:
console#show po?
policy-map

port

ports

Using Command Completion
The CLI can complete partially entered commands when you press the
 or  key.
console#show run
console#show running-config
If the characters you entered are not enough for the switch to identify a single
matching command, continue entering characters until the switch can
uniquely identify the command. Use the question mark (?) to display the
available commands matching the characters already entered.

Entering Abbreviated Commands
To execute a command, you need to enter enough characters so that the
switch can uniquely identify a command. For example, to enter Global
Configuration mode from Privileged EXEC mode, you can enter con instead
of configure.
console#con
console(config)#

Negating Commands
For many commands, the prefix keyword no is entered to cancel the effect of
a command or reset the configuration to the default value. Many
configuration commands have this capability.

114

Using the Command-Line Interface

Understanding Error Messages
If you enter a command and the system is unable to execute it, an error
message appears. Table 5-2 describes the most common CLI error messages.
Table 5-2.

CLI Error Messages

Message Text

Description

% Invalid input
detected at '^'
marker.

Indicates that you entered an incorrect or
unavailable command. The carat (^) shows
where the invalid text is detected. This message
also appears if any of the parameters or values are
not recognized.

Command not found /
Incomplete command.
Use ? to list
commands.

Indicates that you did not enter the required
keywords or values.

Ambiguous command

Indicates that you did not enter enough letters to
uniquely identify the command.

If you attempt to execute a command and receive an error message, use the
question mark (?) to help you determine the possible keywords or parameters
that are available.

Recalling Commands from the History Buffer
Every time a command is entered in the CLI, it is recorded in an internally
managed Command History buffer. By default, the history buffer is enabled
and stores the last 10 commands entered. These commands can be recalled,
reviewed, modified, and reissued. This buffer is not preserved after switch
resets.

Using the Command-Line Interface

115

Table 5-3.

History Buffer Navigation

Keyword

Source or Destination

Up-arrow key

Recalls commands in the history buffer, beginning with the most
recent command. Repeats the key sequence to recall successively
older commands.

+

Down-arrow key + 116 Returns to more recent commands in the history buffer after recalling commands with the up-arrow key. Repeating the key sequence recalls more recent commands in succession. Using the Command-Line Interface 6 Default Settings This section describes the default settings for many of the software features on the PowerConnect 7000 Series switches. Table 6-1. Default Settings Feature Default IP address None Subnet mask None Default gateway None DHCP client Enabled on out-of-band (OOB) interface. VLAN 1 Members All switch ports SDM template Dual IPv4 and IPv6 routing Users None Minimum password length 8 characters IPv6 management mode Enabled SNTP client Disabled Global logging Enabled Switch auditing Disabled CLI command logging Disabled Web logging Disabled SNMP logging Disabled Console logging Enabled (Severity level: warnings and above) RAM logging Enabled (Severity level: Informational and above) Persistent (FLASH) logging Disabled DNS Enabled (No servers configured) Default Settings 117 Table 6-1. Default Settings (Continued) Feature Default SNMP Enabled (SNMPv1) SNMP Traps Enabled Auto Configuration Enabled Auto Save Disabled Stacking Enabled Nonstop Forwarding on the Stack Enabled sFlow Enabled ISDP Enabled (Versions 1 and 2) RMON Enabled TACACS+ Not configured RADIUS Not configured SSH/SSL Disabled Telnet Enabled Denial of Service Protection Disabled Captive Portal Disabled Dot1x Authentication (IEEE 802.1X) Disabled MAC-Based Port Security All ports are unlocked Access Control Lists (ACL) None configured IP Source Guard (IPSG) Disabled DHCP Snooping Disabled Dynamic ARP Inspection Disabled Protected Ports (Private VLAN Edge) None Energy Detect Mode Disabled EEE Lower Power Mode Disabled PoE Plus (PC7024P and PC7048P) Auto Flow Control Support (IEEE 802.3x) Enabled Head of Line Blocking Prevention Disabled 118 Default Settings Table 6-1. Default Settings (Continued) Feature Default Maximum Frame Size 1500 bytes Auto-MDI/MDIX Support Enabled Auto Negotiation Enabled Advertised Port Speed Maximum Capacity Broadcast Storm Control Disabled Port Mirroring Disabled LLDP Enabled LLDP-MED Disabled MAC Table Address Aging 300 seconds (Dynamic Addresses) Cisco Protocol Filtering (LLPF) No protocols are blocked DHCP Layer 2 Relay Disabled Default VLAN ID 1 Default VLAN Name Default GVRP Disabled GARP Timers Leave: 60 centiseconds Leave All: 1000 centiseconds Join: 20 centiseconds Voice VLAN Disabled Guest VLAN Disabled RADIUS-assigned VLANs Disabled Double VLANs Disabled Spanning Tree Protocol (STP) Enabled STP Operation Mode IEEE 802.1w Rapid Spanning Tree Optional STP Features Disabled STP Bridge Priority 32768 Multiple Spanning Tree Disabled Link Aggregation No LAGs configured Default Settings 119 Table 6-1. Default Settings (Continued) Feature Default LACP System Priority 1 Routing Mode Disabled OSPF Admin Mode Enabled OSPF Router ID 0.0.0.0 IP Helper and UDP Relay Enabled RIP Enabled VRRP Disabled Tunnel and Loopback Interfaces None IPv6 Routing Disabled DHCPv6 Disabled OSPFv3 Enabled DiffServ Enabled Auto VoIP Disabled Auto VoIP Traffic Class 6 iSCSI Enabled Bridge Multicast Filtering Enabled MLD Snooping Enabled IGMP Snooping Enabled IGMP Snooping Querier Disabled GMRP Disabled IPv4 Multicast Disabled IPv6 Multicast Disabled 120 Default Settings Setting the IP Address and Other Basic Network Information 7 This chapter describes how to configure basic network information for the switch, such as the IP address, subnet mask, and default gateway. The topics in this chapter include: • IP Address and Network Information Overview • Default Network Information • Configuring Basic Network Information (Web) • Configuring Basic Network Information (CLI) • Basic Network Information Configuration Example IP Address and Network Information Overview What Is the Basic Network Information? The basic network information includes settings that define the PowerConnect 7000 Series switch in relation to the network. Table 7-1 provides an overview of the settings this chapter describes. Table 7-1. Basic Network Information Feature Description IP Address On an IPv4 network, the a 32-bit number that uniquely identifies a host on the network. The address is expressed in dotted-decimal format, for example 192.168.10.1. Subnet Mask Determines which bits in the IP address identify the network, and which bits identify the host. Subnet masks are also expressed in dotted-decimal format, for example 255.255.255.0. Setting Basic Network Information 121 Table 7-1. Basic Network Information (Continued) Feature Description Default Gateway Typically a router interface that is directly connected to the switch and is in the same subnet. The switch sends IP packets to the default gateway when it does not recognize the destination IP address in a packet. DHCP Client Requests network information from a DHCP server on the network. Domain Name System (DNS) Server Translates hostnames into IP addresses. The server maintains a domain name databases and their corresponding IP addresses. Default Domain Name Identifies your network, such as dell.com. If you enter a hostname and do not include the domain name information, the default domain name is automatically appended to the hostname. Host Name Mapping Allows you to statically map an IP address to a hostname. Additionally, this chapter describes how to view host name-to-IP address mappings that have been dynamically learned by the system. Why Is Basic Network Information Needed? PowerConnect 7000 Series switches are layer 2/3 managed switches. To manage the switch remotely by using a web browser or Telnet client, the switch must have an IP address, subnet mask, and default gateway. You must also configure a username and password to be able to log into the switch from a remote host. For information about configuring users, see "Configuring Authentication, Authorization, and Accounting" on page 175. If you manage the switch only by using a console connection, configuring an IP address and user is not required. NOTE: The configuration example in this chapter includes commands to create an administrative user with read/write access. Configuring the DNS information, default domain name, and host name mapping help the switch identify and locate other devices on the network and on the Internet. For example, to upgrade the switch software by using a TFTP 122 Setting Basic Network Information server on the network, you must identify the TFTP server. If you configure the switch to use a DNS server to resolve hostnames into IP addresses, you can enter the hostname of the TFTP server instead of the IP address. It is often easier to remember a hostname than an IP address, and if the IP address is dynamically assigned, it might change from time-to-time. How Is Basic Network Information Configured? You must use a console-port connection to perform the initial switch configuration. When you boot the switch for the first time and the configuration file is empty, the Dell Easy Setup Wizard starts. The Dell Easy Setup Wizard is a CLI-based tool to help you perform the initial switch configuration. If you do not respond to the Dell Easy Setup Wizard prompt within 60 seconds, the console> prompt appears, and you enter User Configuration mode. For more information about performing the initial switch configuration by using the wizard, see the Getting Started Guide at support.dell.com/manuals. If you do not use the wizard to prompt you for the initial configuration information, you can enable the DHCP client on the switch to obtain network information from a DHCP server on your network, or you can statically assign the network information. After you configure the switch with an IP address and create a user account, you can continue to use the console connection to configure basic network information, or you can log on to the switch by using a Telnet client or a web browser. You can change the IP address information and configure additional network information from the remote system. What Is Out-of-Band Management and In-Band Management? The PowerConnect 7000 Series switches have an external port intended solely for management of the switch. This port is the out-of-band (OOB) management port. Traffic received on the OOB port is never switched or routed to any in-band port and is not rate limited. Likewise, traffic received on any in-band port is never forwarded or routed over the OOB port. The only applications available on the OOB port are protocols required to manage the switch, for example telnet, SSH, DHCP client, and TFTP. If using the out-ofband management port, it is strongly recommended that the port be connected only to a physically isolated secure management network. Setting Basic Network Information 123 Alternatively, network administrators may choose to manage their network via the production network. This is in-band management. Because in-band management traffic is mixed in with production network traffic, it is subject to all of the filtering rules usually applied on a switched/routed port, such as ACLs and VLAN tagging, and is rate limited to protect against DoS attacks. You can assign an IP address to OOB management port and to any VLAN. By default, all ports are members of VLAN 1. If you assign an IP address to VLAN 1, you can connect to the switch management interface by using any of the frontpanel switch ports. Dell recommends that you use the OOB port for remote management. The following list highlights some advantages of using OOB management instead of in-band management: • Traffic on the OOB port is segregated from traffic on the production network, so you can keep the management traffic and network traffic separate. • If the production network is experiencing problems, you can still access the switch management interface and troubleshoot issues. • Because the OOB port is intended to be physically isolated from the production network, configuration options are limited to just those protocols needed to manage the switch. Limiting the configuration options makes it difficult to accidentally cut off management access to the switch. DHCP can be enabled on the OOB interface and all VLAN interfaces simultaneously, or you can configure static information. To configure static address information on the default VLAN, set the IP address and subnet mask on the VLAN interface and configure a global default gateway for the switch. Adjusting the Management Interface MTU When logging in to the PowerConnect switch using TCP, the switch negotiates the TCP Maximum Segment Size (MSS) using the minimum of the requested MSS or the MTU setting of the port. TCP packets are transmitted from the switch with the DF (Don't Fragment) bit set in order to receive notification of fragmentation from any transit routers. Upon receiving an ICMP Destination Unreachable, Fragmentation needed but DF set 124 Setting Basic Network Information notification, the switch will reduce the MSS. However, many firewalls block ICMP Destination Unreachable messages, which causes the destination to request the packet again until the connection times out. In order to resolve this issue, you can reduce the MSS setting to a more appropriate value on the local host or alternatively, you can set the MTU on the PowerConnect management port to a smaller value. Default Network Information By default, no network information is configured. The DHCP client is enabled on the OOB interface by default. DNS is enabled, but no DNS servers are configured. Setting Basic Network Information 125 Configuring Basic Network Information (Web) This section provides information about the OpenManage Switch Administrator pages for configuring and monitoring basic network information on the PowerConnect 7000 Series switch. For details about the fields on a page, click at the top of the page. Out-of-Band Interface Use the Out of Band Interface page to assign the Out of Band Interface IP address and subnet mask or to enable/disable the DHCP client for address information assignment. DHCP is enabled by default on the OOB interface. To display the Out of Band Interface page, click System → IP Addressing → Out of Band Interface in the navigation panel. Figure 7-1. Out of Band Interface To enable the DHCP client and allow a DHCP server on your network to automatically assign the network information to the OOB interface, select DHCP from the Protocol menu. If you statically assign the network information, make sure the Protocol menu is set to None. 126 Setting Basic Network Information IP Interface Configuration (Default VLAN IP Address) Use the IP Interface Configuration page to assign the Default VLAN IP address and Subnet Mask, the Default Gateway IP address, and to assign the boot protocol. To display the IP Interface Configuration page, click Routing → IP → IP Interface Configuration in the navigation panel. Figure 7-2. IP Interface Configuration (Default VLAN) Assigning Network Information to the Default VLAN To assign an IP Address and subnet mask to the default VLAN: 1 From the Interface menu, select VLAN 1. 2 From the Routing Mode field, select Enable. 3 From the IP Address Configuration Method field specify whether to assign a static IP address (Manual) or use DHCP for automatic address assignment. Setting Basic Network Information 127 4 If you select Manual for the configuration method, specify the IP Address and Subnet Mask in the appropriate fields. 5 Click Apply. NOTE: You do not need to configure any additional fields on the page. For information about VLAN routing interfaces, see "Configuring Routing Interfaces" on page 843. Route Entry Configuration (Switch Default Gateway) Use the Route Entry Configuration page to configure the default gateway for the switch. The Default VLAN uses the switch default gateway as its default gateway. To display the Route Entry Configuration page, click Routing → Router → Route Entry Configuration in the navigation panel. Figure 7-3. Route Configuration (Default VLAN) 128 Setting Basic Network Information Configuring a Default Gateway for the Switch: To configure the switch default gateway: 1 Open the Route Entry Configuration page. 2 From the Route Type field, select Default. Figure 7-4. Default Route Configuration (Default VLAN) 3 In the Next Hop IP Address field, enter the IP address of the default gateway. 4 Click Apply. For more information about configuring routes, see "Configuring IP Routing" on page 883. Setting Basic Network Information 129 Domain Name Server Use the Domain Name Server page to configure the IP address of the DNS server. The switch uses the DNS server to translate hostnames into IP addresses. To display the Domain Name Server page, click System → IP Addressing → Domain Name Server in the navigation panel. Figure 7-5. DNS Server To configure DNS server information, click the Add link and enter the IP address of the DNS server in the available field. Figure 7-6. Add DNS Server 130 Setting Basic Network Information Default Domain Name Use the Default Domain Name page to configure the domain name the switch adds to a local (unqualified) hostname. To display the Default Domain Name page, click System → IP Addressing → Default Domain Name in the navigation panel. Figure 7-7. Default Domain Name Setting Basic Network Information 131 Host Name Mapping Use the Host Name Mapping page to assign an IP address to a static host name. The Host Name Mapping page provides one IP address per host. To display the Host Name Mapping page, click System → IP Addressing → Host Name Mapping. Figure 7-8. Host Name Mapping To map a host name to an IP address, click the Add link, type the name of the host and its IP address in the appropriate fields, and then click Apply. Figure 7-9. Add Static Host Name Mapping Use the Show All link to view all configured host name-to-IP address mappings. 132 Setting Basic Network Information Dynamic Host Name Mapping Use the Dynamic Host Name Mapping page to view dynamic host entries the switch has learned. The switch learns hosts dynamically by using the configured DNS server to resolve a hostname. For example, if you ping www.dell.com from the CLI, the switch uses the DNS server to lookup the IP address of dell.com and adds the entry to the Dynamic Host Name Mapping table. To display the Dynamic Host Name Mapping page, click System → IP Addressing → Dynamic Host Name Mapping in the navigation panel. Figure 7-10. View Dynamic Host Name Mapping Setting Basic Network Information 133 Configuring Basic Network Information (CLI) This section provides information about the commands you use to configure basic network information on the PowerConnect 7000 Series switch. For more information about these commands, see the PowerConnect 7000 Series CLI Reference Guide at support.dell.com/manuals. Enabling the DHCP Client on the OOB Port Beginning in Privileged EXEC mode, use the following commands to enable the DHCP client on the OOB port. Command Purpose configure Enter Global Configuration mode. interface out-of-band Enter Interface Configuration mode for the OOB port. ip address dhcp Enable the DHCP client. CTRL + Z Exit to Privileged EXEC mode. show ip interface out-of- Display network information for the OOB port. band Enabling the DHCP Client on the Default VLAN Beginning in Privileged EXEC mode, use the following commands to enable the DHCP client on the default VLAN, which is VLAN 1. Command Purpose configure Enter Global Configuration mode. interface vlan 1 Enter Interface Configuration mode for VLAN 1. ip address dhcp Enable the DHCP client. ipv6 address dhcp Enable the DHCPv6 client. CTRL + Z Exit to Privileged EXEC mode. show ip interface vlan 1 Display network information for VLAN 1. 134 Setting Basic Network Information Managing DHCP Leases Beginning in Privileged EXEC mode, use the following commands to manage and troubleshoot DHCP leases on the switch. Command Purpose release dhcp interface Force the DHCPv4 client to release a leased address on the specified interface. renew dhcp interface Force the DHCP client to immediately renew an IPv4 address lease. show dhcp lease interface [interface] Display IPv4 addresses leased from a DHCP server. show ipv6 dhcp interface Display information about the IPv6 DHCP information [interface] for all interfaces or for the specified interface. debug dhcp packet Display debug information about DHCPv4 client activities and to trace DHCPv4 packets to and from the local DHCPv4 client. debug ipv6 dhcp Display debug information about DHCPv6 client activities and to trace DHCPv6 packets to and from the local DHCPv6 client. Setting Basic Network Information 135 Configuring Static Network Information on the OOB Port Beginning in Privileged EXEC mode, use the following commands to configure a static IP address, subnet mask, and default gateway on the OOB port. Command Purpose configure Enter Global Configuration mode. interface out-of-band Enter Interface Configuration mode for the OOB port. ip address ip_address subnet_mask [gateway_ip] Configure a static IP address and subnet mask. Optionally, you can also configure a default gateway. CTRL + Z Exit to Privileged EXEC mode. show ip interface out-of-band Verify the network information for the OOB port. Configuring Static Network Information on the Default VLAN Beginning in Privileged EXEC mode, use the following commands to configure a static IP address, subnet mask, and default gateway on the default VLAN. Command Purpose configure Enter Global Configuration mode. interface vlan 1 Enter Interface Configuration mode for VLAN 1. ip address ip_address subnet_mask Enter the IP address and subnet mask. ipv6 address prefix/prefix-length [eui64] Enter the IPv6 address and prefix. ipv6 enable Enable IPv6 on the interface. exit Exit to Global Configuration mode ip default-gateway ip_address Configure the default gateway. exit Exit to Privileged Exec mode. show ip interface vlan 1 Verify the network information for VLAN 1. show ipv6 interface vlan 1 Verify IPv6 network information for VLAN 1. 136 Setting Basic Network Information Configuring and Viewing Additional Network Information Beginning in Privileged EXEC mode, use the following commands to configure a DNS server, the default domain name, and a static host name-toaddress entry. Use the show commands to verify configured information and to view dynamic host name mappings. Command Purpose configure Enter Global Configuration mode. ip domain-lookup Enable IP DNS-based host name-to-address translation. ip name-server Enter the IP address of an available name server to use to resolve host names and IP addresses. ip_address You can specify up to six DNS servers. The first server you configure is the primary DNS server. ip domain-name name Define a default domain name to complete unqualified host names. ip host name ip_address Use to configure static host name-to-address mapping in the host cache. ip address-conflictdetect run Trigger the switch to run active address conflict detection by sending gratuitous ARP packets for IPv4 addresses on the switch. CTRL + Z Exit to Privileged EXEC mode. show ip interface vlan 1 Verify the network information for VLAN 1. show hosts Verify the configured network information and view the dynamic host mappings. show ip address-conflict View the status information corresponding to the last detected address conflict. clear ip address-conflict- Clear the address conflict detection status in the switch. detect Setting Basic Network Information 137 Basic Network Information Configuration Example In this example, an administrator at a Dell office in California decides not to use the Dell Easy Setup Wizard to perform the initial switch configuration. The administrator configures a PowerConnect 7000 Series switch to obtain its information from a DHCP server on the network and creates the administrative user with read/write access. The administrator also configures the following information: • Primary DNS server: 10.27.138.20 • Secondary DNS server: 10.27.138.21 • Default domain name: sunny.dell.com The administrator also maps the administrative laptop host name to its IP address. The administrator uses the OOB port to manage the switch. To configure the switch: 1 Connect the OOB port to the management network. DHCP is enabled by on the switch OOB interface by default. If the DHCP client on the switch has been disabled, use the following commands to enable the DHCP client on the OOB port. console#configure console(config)#interface out-of-band console(config-if)#ip address dhcp console(config-if)#exit 2 Configure the administrative user. console(config)#username admin password secret123 level 15 3 Configure the DNS servers, default domain name, and static host mapping. console(config)#ip name-server 10.27.138.20 10.27.138.21 console(config)#ip domain-name sunny.dell.com console(config)#ip host admin-laptop 10.27.65.103 console(config)#exit 138 Setting Basic Network Information 4 View the network information that the DHCP server on the network dynamically assigned to the switch. console#show ip interface out-of-band IP Address........................ 10.27.22.153 Subnet Mask...................... 255.255.255.0 Default Gateway.................. 10.27.22.1 Protocol Current................. DHCP Burned In MAC Address............ 001E.C9AA.AA08 5 View additional network information. console#show hosts Host name: Default domain: sunny.dell.com dell.com Name/address lookup is enabled Name servers (Preference order): 10.27.138.20, 10.27.138.21 Configured host name-to-address mapping: Host Addresses ----------- -----------------------------------admin-laptop 10.27.65.103 cache: TTL (Hours) Host Total Elapsed Type Addresses --------- ------- ------- --------- --------No hostname is mapped to an IP address 6 Verify that the static hostname is correctly mapped. console#ping admin-laptop Pinging admin-laptop with 0 bytes of data: Reply From 10.27.65.103: icmp_seq = 0. time <10 msec. Reply From 10.27.65.103: icmp_seq = 1. time <10 msec. Setting Basic Network Information 139 140 Setting Basic Network Information Managing a Switch Stack 8 This chapter describes how to configure and manage a stack of switches. The topics covered in this chapter include: • Stacking Overview • Default Stacking Values • Managing and Monitoring the Stack (Web) • Managing the Stack (CLI) • Stacking and NSF Usage Scenarios Stacking Overview PowerConnect 7000 Series switches include a stacking feature that allows up to 12 switches to operate as a single unit. The PowerConnect 7000 Series switches have two plug-in modules at the rear. Each module has two ports which can be SFP+, 10GBase-T, or CX-4. The CX-4 ports can be configured to operate as either 10GbE switching or 16 Gb HiGig2 uplinks for stacking. PowerConnect 7000 Series switches will stack with each other and the PC6348 switches. A single switch in the stack manages all the units in the stack (the stack master), and you manage the stack by using a single IP address. The IP address of the stack does not change, even if the stack master changes. NOTE: Each PowerConnect 7000 Series switch in the stack must have the optional Stacking module installed in one of the two expansion slots on the back panel. Figure 3-13 in Expansion Slots for Plug-in Modules shows the stacking module. A stack is created by daisy-chaining stacking links on adjacent units. Up to eight links per stack unit can be used for stacking (four in each direction). A stack of units is manageable as a single entity when the units are connected together. If a unit cannot detect a stacking partner on any port enabled for stacking, the unit automatically operates as a standalone unit. If a stacking partner is detected, the switch always operates in stacking mode. One unit in Managing a Switch Stack 141 the stack is designated as the stack master. The master manages all the units in the stack. The stack master runs the user interface and switch software, and propagates changes to the member units. To manage a stack using the serial interface, you must connect to the serial port on the stack master. The serial interface on member units does not allow access to the CLI. A second switch is designated as the standby unit, which becomes the master if the stack master is unavailable. You can manually configure which unit is selected as the standby, or the system can select the standby automatically. When units are in a stack, the following activities occur: • All units are checked for software version consistency. • The switch Control Plane is active only on the master. The Control Plane is a software layer that manages system and hardware configuration and runs the network control protocols to set system configuration and state. • The switch Data Plane is active on all units in the stack, including the master. The Data Plane is the set of hardware components that forward data packets without intervention from a control CPU. • The running configuration is propagated to all units and the application state is synchronized between the master and standby during normal stacking operation. The startup configuration and backup configuration on the stack members are not overwritten with the master switch configuration. Dell strongly recommends connecting the stack in a ring topology so that each switch is connected to two other switches. Connecting switches in a ring topology allows the stack to utilize the redundant communication path to each switch. If a switch in a ring topology fails, the stack can automatically establish a new communications path to the other switches. Switches not stacked in a ring topology may split into multiple independent stacks upon the failure of a single switch or stacking link. Additional stacking connections can be made between adjacent switch units to increase the stacking bandwidth, provided that all redundant stacking links have the same bandwidth. It is strongly recommended that the stacking bandwidth be kept equal across of all stacking connections; that is, avoid mixing single and double stacking connections within a stack. Up to eight redundant stacking links can be configured on a stacking unit (four in each direction). 142 Managing a Switch Stack Figure 8-1 shows a stack with three switches as stack members connected in a ring topology. Figure 8-1. Connecting a Stack of Switches XG1 Port XG2 Port Unit 1 Unit 2 Unit 3 The stack in Figure 8-1 has the following physical connections between the switches: • The XG1 port on Unit 1 is connected to the XG2 port on Unit 2. • The XG1 port on Unit 2 is connected to the XG2 port on Unit 3. • The XG1 port on Unit 3 is connected to the XG2 port on Unit 1. PowerConnect 7000 Series and M6348 Stacking Compatibility The stack can contain any combination of switch models in the PowerConnect 7000 Series as well as the PowerConnect M6348 switch, as long as all switches are running the same firmware version. For example, a single stack of six switches might include the following members: • Two PC7048 switches • One PC7024 switch • Three PCM6348 switches Any member can be the stack master. How is the Stack Master Selected? A stack master is elected or re-elected based on the following considerations, in order: Managing a Switch Stack 143 1 The switch is currently the stack master. 2 The switch has the higher MAC address. 3 A unit is selected as standby by the administrator, and a fail over action is manually initiated or occurs due to stack master failure. In most cases, a switch that is added to an existing stack will become a stack member, and not the stack master. When you add a switch to the stack, one of the following scenarios takes place regarding the management status of the new switch: • If the switch has the stack master function enabled but another stack master is already active, then the switch changes its configured stack master value to disabled. • If the stack master function is unassigned and there is another stack master in the system then the switch changes its configured stack master value to disabled. • If the stack master function is enabled or unassigned and there is no other stack master in the system, then the switch becomes stack master. • If the stack master function is disabled, the unit remains a non-stack master. If the entire stack is powered OFF and ON again, the unit that was the stack master before the reboot will remain the stack master after the stack resumes operation. You can manually set the unit number for the switch. To avoid unit-number conflicts, one of the following scenarios takes place when you add a new member to the stack: 144 • If the switch has a unit number that is already in use, then the unit that you add to the stack changes its configured unit number to the lowest unassigned unit number. • If the switch you add does not have an assigned unit number, then the switch sets its configured unit number to the lowest unassigned unit number. • If the unit number is configured and there are no other devices using the unit number, then the switch starts using the configured unit number. Managing a Switch Stack • If the switch detects that the maximum number of units already exist in the stack making it unable to assign a unit number, then the switch sets its unit number to unassigned and does not participate in the stack. Adding a Switch to the Stack When adding a new member to a stack, make sure that only the stack cables, and no network cables, are connected before powering up the new unit. Stack port configuration is stored on the member units. If stacking over Ethernet ports, configure the ports on the unit to be added to the stack as stacking ports and power the unit off prior to connecting the stacking cables. Make sure the links are not already connected to any ports of that unit. This is important because if STP is enabled and any links are UP, the STP reconvergence will take place as soon as the link is detected. After the stack cables on the new member are connected to the stack, you can power up the new units, beginning with the unit directly attached to the currently powered-up unit. Always power up new stack units closest to an existing powered unit first. Do not connect a new member to the stack after it is powered up. Also, do not connect two functional, powered-up stacks together. Hot insertion of units into a stack is not supported. If a new switch is added to a stack of switches that are powered and running and already have an elected stack master, the newly added switch becomes a stack member rather than the stack master. In this situation, the firmware of the new unit may be overwritten based on the configuration of the stack master. The running configuration of the newly added unit is overwritten with the stack master configuration. Stack port configuration is always stored on the local unit and may be updated with preconfiguration information from the stack master when the unit joins the stack. You can preconfigure information about a stack member and its ports before you add it to the stack. The preconfiguration takes place on the stack master. If there is saved configuration information on the stack master for the newly added unit, the stack master applies the configuration to the new unit; otherwise, the stack master applies the default configuration to the new unit. Managing a Switch Stack 145 Removing a Switch from the Stack Prior to removing a member from a stack, check that other members of the stack will not become isolated from the stack due to the removal. Check the stack-port error counters to ensure that a stack configured in a ring topology can establish a communication path around the member to be removed. The main point to remember when you remove a unit from the stack is to disconnect all the links on the stack member to be removed. Also, be sure to take the following actions: • Remove all the STP participating ports and wait to stabilize the STP. • Remove all the member ports of any Port-Channels (LAGs) so there will not be any control traffic destined to those ports connected to this member. • Statically re-route any traffic going through this unit. When a unit in the stack fails, the stack master removes the failed unit from the stack. The failed unit reboots with its original running-config. If the stack is configured in a ring topology, then the stack automatically routes around the failed unit. If the stack is not configured in a ring topology, then the stack may split, and the isolated members will reboot and re-elect a new stack master. No changes or configuration are applied to the other stack members; however, the dynamic protocols will try to reconverge as the topology could change because of the failed unit. If you remove a unit and plan to renumber the stack, issue a no member unit command in Stack Configuration mode to delete the removed switch from the configured stack member information. How is the Firmware Updated on the Stack? When you add a new switch to a stack, the Stack Firmware Synchronization feature automatically synchronizes the firmware version with the version running on the stack master per the configuration on the master switch. The synchronization operation may result in either upgrade or downgrade of firmware on the mismatched stack member. Upgrading the firmware on a stack of switches is the same as upgrading the firmware on a single switch. After you download a new image by using the File Download page or copy command, the downloaded image is distributed to all the connected units of the stack. For more information about downloading and installing images, see "Managing Images and Files" on page 319. 146 Managing a Switch Stack What is Stacking Standby? A standby unit is preconfigured in the stack. If the current stack master fails, the standby unit becomes the stack master. If no switch is pre-configured as the standby unit, the software automatically selects a standby unit from the existing stack units. When the failed master resumes normal operation, it joins the stack as a member (not a master) if the new stack master has already been elected. The stack master copies its running configuration to the standby unit whenever it changes (subject to some restrictions to reduce overhead). This enables the standby unit to take over the stack operation with minimal interruption if the stack master becomes unavailable. Operational state synchronization also occurs: • when you save the running configuration to the startup configuration on the stack master. • when the backup unit changes. What is Nonstop Forwarding? Networking devices, such as the PowerConnect 7000 Series switches, are often described in terms of three semi-independent functions called the forwarding plane, the control plane, and the management plane. The forwarding plane forwards data packets and is implemented in hardware. The control plane is the set of protocols that determine how the forwarding plane should forward packets, deciding which data packets are allowed to be forwarded and where they should go. Application software on the stack master acts as the control plane. The management plane is application software running on the stack master that provides interfaces allowing a network administrator to configure the device. The Nonstop Forwarding (NSF) feature allows the forwarding plane of stack units to continue to forward packets while the control and management planes restart as a result of a power failure, hardware failure, or software fault on the stack master. This type of operation is called nonstop forwarding. When the stack master fails, only the switch ASICs on the stack master need to be restarted. To prevent adjacent networking devices from rerouting traffic around the restarting device, the NSF feature uses the following three techniques: Managing a Switch Stack 147 1 A protocol can distribute a part of its control plane to stack units so that the protocol can give the appearance that it is still functional during the restart. 2 A protocol may enlist the cooperation of its neighbors through a technique known as graceful restart. 3 A protocol may simply restart after the failover if neighbors react slowly enough that they will not normally detect the outage. The NSF feature enables the stack master unit to synchronize the runningconfig within 60 seconds after a configuration change has been made. However, if a lot of configuration changes happen concurrently, NSF uses a back-off mechanism to reduce the load on the switch. The show nsf command output includes information about when the next running-config synchronization will occur. Initiating a Failover The NSF feature allows you to initiate a failover using the initiate failover command, which causes the former stack master to reboot (cold start), and the new master to perform a warm restart. Initiating a failover reloads the stack master, triggering the backup unit to take over. Before the failover, the stack master pushes application data and other important information to the backup unit. Although the handoff is controlled and causes minimal network disruption, some application state is lost, such as pending timers and other pending internal events. Checkpointing Switch applications (features) that build up a list of data such as neighbors or clients can significantly improve their restart behavior by remembering this data across a warm restart. This data can either be stored persistently, as DHCP server and DHCP snooping store their bindings database, or the stack master can checkpoint this data directly to the standby unit. Persistent storage allows an application on a standalone unit to retain its data across a restart, but since the amount of storage is limited, persistent storage is not always practical. 148 Managing a Switch Stack The NSF checkpoint service allows the stack master to communicate certain data to the backup unit in the stack. When the stack selects a backup unit, the checkpoint service notifies applications to start a complete checkpoint. After the initial checkpoint is done, applications checkpoint changes to their data. NOTE: The switch cannot guarantee that a backup unit has exactly the same data that the stack master has when it fails. For example, the stack master might fail before the checkpoint service gets data to the backup if an event occurs shortly before a failover. Table 8-1 lists the applications on the switch that checkpoint data and describes the type of data that is checkpointed. Table 8-1. Applications that Checkpoint Data Application Checkpointed Data ARP Dynamic ARP entries Auto VOIP Calls in progress Captive Portal Authenticated clients DHCP server Address bindings (persistent) DHCP snooping DHCP bindings database DOT1Q Internal VLAN assignments DOT1S Spanning tree port roles, port states, root bridge, etc. DOT1X Authenticated clients DOT3ad Port states IGMP/MLD Snooping Multicast groups, list of router ports, last query data for each VLAN IPv6 NDP Neighbor cache entries iSCSI Connections LLDP List of interfaces with MED devices attached OSPFv2 Neighbors and designated routers OSPFv3 Neighbors and designated routers Route Table Manager IPv4 and IPv6 dynamic routes Managing a Switch Stack 149 Table 8-1. Applications that Checkpoint Data Application Checkpointed Data SIM The system's MAC addresses. System up time. IP address, network mask, default gateway on each management interface, DHCPv6 acquired IPv6 address. Voice VLAN VoIP phones identified by CDP or DHCP (not LLDP) Switch Stack MAC Addressing and Stack Design Considerations The switch stack uses the MAC addresses assigned to the stack master. NOTE: Each switch is assigned three consecutive MAC addresses. The switch uses the MAC addresses for the service port, network port, and routing interfaces. A stack of switches uses the MAC addresses assigned to the stack master. If the backup unit assumes control due to a stack master failure or warm restart, the backup unit continues to use the original stack master’s MAC addresses. This reduces the amount of disruption to the network because ARP and other L2 entries in neighbor tables remain valid after the failover to the backup unit. Stack units should always be connected with a ring topology (or other biconnected topology), so that the loss of a single stack link does not divide the stack into multiple stacks. If a stack is partitioned such that some units lose all connectivity to other units, then both parts of the stack start using the same MAC addresses. This can cause severe problems in the network. If you move the stack master to a different place in the network, make sure you power down the whole stack before you redeploy the stack master so that the stack members do not continue to use the MAC address of the redeployed switch. NSF Network Design Considerations You can design your network to take maximum advantage of NSF. For example, by distributing a LAG's member ports across multiple units, the stack can quickly switch traffic from a port on a failed unit to a port on a surviving unit. When a unit fails, the forwarding plane of surviving units removes LAG members on the failed unit so that it only forwards traffic onto 150 Managing a Switch Stack LAG members that remain up. If a LAG is left with no active members, the LAG goes down. To prevent a LAG from going down, configure LAGs with members on multiple units within the stack, when possible. If a stack unit fails, the system can continue to forward on the remaining members of the stack. If your switch stack performs VLAN routing, another way to take advantage of NSF is to configure multiple “best paths” to the same destination on different stack members. If a unit fails, the forwarding plane removes Equal Cost Multipath (ECMP) next hops on the failed unit from all unicast forwarding table entries. If the cleanup leaves a route without any next hops, the route is deleted. The forwarding plane only selects ECMP next hops on surviving units. For this reason, try to distribute links providing ECMP paths across multiple stack units. Why is Stacking Needed? Stacking increases port count without requiring additional configuration. If you have multiple PowerConnect switches, stacking them helps make management of the switches easier because you configure the stack as a single unit and do not need to configure individual switches. Default Stacking Values Stacking is always enabled on PowerConnect 7000 Series switches. By default, the CX-4 ports are in stacking mode, not Ethernet mode. NSF is enabled by default. You can disable NSF in order to redirect the CPU resources consumed by data checkpointing. Checkpointing only occurs when a backup unit is elected, so there is no need to disable the NSF feature on a standalone switch. When a new unit is added to the stack, the new unit takes the configuration of the stack, including the NSF setting. Managing a Switch Stack 151 Managing and Monitoring the Stack (Web) This section provides information about the OpenManage Switch Administrator pages for configuring and monitoring stacking on a PowerConnect 7000 Series switch. For details about the fields on a page, click at the top of the page. NOTE: The changes you make to the Stacking configuration pages take effect only after the device is reset. Unit Configuration Use the Unit Configuration page to change the unit number and unit type (Management, Member, or Standby). To display the Unit Configuration page, click System → Stack Management → Unit Configuration in the navigation panel. Figure 8-2. Stack Unit Configuration 152 Managing a Switch Stack Changing the ID or Switch Type for a Stack Member To change the switch ID or type: 1 Open the Unit Configuration page. 2 Click Add to display the Add Unit page. Figure 8-3. Add Remote Log Server Settings 3 Specify the switch ID, and select the model number of the switch. 4 Click Apply. Managing a Switch Stack 153 Stack Summary Use the Stack Summary page to view a summary of switches participating in the stack. To display the Stack Summary page, click System → Stack Management → Stack Summary in the navigation panel. Figure 8-4. Stack Summary 154 Managing a Switch Stack Stack Firmware Synchronization Use the Stack Firmware Synchronization page to control whether the firmware image on a new stack member can be automatically upgraded or downgraded to match the firmware image of the stack master. To display the Stack Firmware Synchronization page, click System → Stack Management → Stack Firmware Synchronization in the navigation panel. Figure 8-5. Stack Firmware Synchronization Managing a Switch Stack 155 Supported Switches Use the Supported Switches page to view information regarding each type of supported switch for stacking, and information regarding the supported switches. To display the Supported Switches page, click System → Stack Management → Supported Switches in the navigation panel. Figure 8-6. Supported Switches 156 Managing a Switch Stack Stack Port Summary Use the Stack Port Summary page to configure the stack-port mode and to view information about the stackable ports. This screen displays the unit, the stackable interface, the configured mode of the interface, the running mode as well as the link status and link speed of the stackable port. To display the Stack Port Summary page, click System → Stack Management → Stack Port Summary in the navigation panel. Figure 8-7. Stack Port Summary Managing a Switch Stack 157 Stack Port Counters Use the Stack Port Counters page to view the transmitted and received statistics, including data rate and error rate. To display the Stack Port Counters page, click System → Stack Management → Stack Point Counters in the navigation panel. Figure 8-8. Stack Port Counters Stack Port Diagnostics The Stack Port Diagnostics page is intended for Field Application Engineers (FAEs) and developers only 158 Managing a Switch Stack NSF Summary Use the NSF Summary page to change the administrative status of the NSF feature and to view NSF information. NOTE: The OSPF feature uses NSF to enable the hardware to continue forwarding IPv4 packets using OSPF routes while a backup unit takes over stack master responsibility. To configure NSF on a stack that uses OSPF or OSPFv3, see "NSF OSPF Configuration" on page 957 and "NSF OSPFv3 Configuration" on page 974. To display the NSF Summary page, click System → Stack Management → NSF Summary in the navigation panel. Figure 8-9. NSF Summary To cause the maser unit to failover to the standby unit, click Initiate Failover. The failover results in a warm restart of the stack master. Initiating a failover reloads the stack master, triggering the backup unit to take over. Managing a Switch Stack 159 Checkpoint Statistics Use the Checkpoint Statistics page to view information about checkpoint messages generated by the stack master. To display the Checkpoint Statistics page, click System → Stack Management → Checkpoint Statistics in the navigation panel. Figure 8-10. Checkpoint Statistics 160 Managing a Switch Stack Managing the Stack (CLI) This section provides information about the commands you use to manage the stack and view information about the switch stack. For more information about these commands, see the PowerConnect 7000 Series CLI Reference Guide at support.dell.com/manuals. Configuring Stack Member, Stack Port, and NSF Settings Beginning in Privileged EXEC mode, use the following commands to configure stacking and NSF settings. Command Purpose configure Enter Global Configuration mode. switch current_ID renumber new_ID Change the switch ID number. The valid range is 1-10. NOTE: Changing the ID number causes all switches in the stack to be reset to perform stack master renumbering. The running configuration is cleared when the units reset. stack Enter Global Stack Configuration mode. initiate failover Move the management switch functionality from the master switch to the standby switch. standby unit Specify the stack member that will come up as the master if a stack failover occurs. set description unit Configure a description for the specified stack member. Managing a Switch Stack 161 Command Purpose member unit SID Add a switch to the stack and specify the model of the new stack member. • unit - The switch unit ID • SID - The index into the database of the supported switch types, indicating the type of the switch being preconfigured. Note: Member configuration displayed in the running config may be learned from the physical stack. Member configuration is not automatically saved in the startupconfig. Save the configuration to retain the current member settings. To view the SID associated with the supported switch types, use the show supported switchtype command in Privileged EXEC mode. stack-port Set the mode of the port to either Ethernet or stacking. tengigabitethernet unit/slot/port {ethernet | stack} nsf Enable nonstop forwarding on the stack. exit Exit to Global Config mode. boot auto-copy-sw Enable the Stack Firmware Synchronization feature. boot auto-copy-sw allow- Allow the firmware version on the newly added stack downgrade member to be downgraded if the firmware version on manager is older. exit Exit to Privileged EXEC mode. show auto-copy-sw View the Stack Firmware Synchronization settings for the stack. reload unit If necessary, reload the specified stack member. NOTE: The OSPF feature uses NSF to enable the hardware to continue forwarding IPv4 packets using OSPF routes while a backup unit takes over stack master responsibility. Additional NSF commands are available in OSPF and OSPFv3 command modes. For more information, see "NSF OSPF Configuration" on page 957 and "NSF OSPFv3 Configuration" on page 974 162 Managing a Switch Stack Viewing and Clearing Stacking and NSF Information Beginning in Privileged EXEC mode, use the following commands to view stacking information and to clear NSF statistics. Command Purpose show switch [stack- member-number] View information about all stack members or the specified member. show switch stackstandby View the ID of the switch that will assume the role of the stack master if it goes down. show switch stack-port View information about the stacking ports. show switch stack-port counters View the statistics about the data the stacking ports have transmitted and received. show supported switchtype View the PowerConnect models that are supported in the stack and the switch index (SID) associated with each model. show nsf View summary information about the NSF feature. show checkpoint statistics View information about checkpoint messages generated by the stack master. clear checkpoint statistics Reset the checkpoint statistics counters to zero. Stacking and NSF Usage Scenarios Only a few settings are available to control the stacking configuration, such as the designation of the standby unit or enabling/disabling NSF. The examples in this section describe how the stacking and NSF feature act in various environments. This section contains the following examples: • Basic Failover • Preconfiguring a Stack Member • NSF in the Data Center • NSF and VoIP • NSF and DHCP Snooping Managing a Switch Stack 163 • NSF and the Storage Access Network • NSF and Routed Access Basic Failover In this example, the stack has four members that are connected in a ring topology, as Figure 8-11 shows. Figure 8-11. Basic Stack Failover When all four units are up and running, the show switch CLI command gives the following output: console#show switch SW Management Status Standby Status --1 2 3 4 --------Stack Member Stack Member Mgmt Switch Stack Member ------- 164 Managing a Switch Stack Preconfig PluggedModel ID in Model ID -------- --------PCT7048 PCT7048 PCT7048 PCT7048 PCT7048 PCT7048 PCT7048 PCT7048 Switch Code Status Version ------- -------OK 9.19.0.2 OK 9.19.0.2 OK 9.19.0.2 OK 9.19.0.2 At this point, if Unit 2 is powered off or rebooted due to an unexpected failure, show switch gives the following output: console#show switch SW Management Status Standby Preconfig Plugged- Switch Status Model ID in Model Status ID --- --------------- -------- ------------------1 Stack Member PCT7048 PCT7048 OK 2 Unassigned PCT7048 Not Present 3 Mgmt Switch PCT7048 PCT7048 OK 4 Stack Member PCT7048 PCT7048 OK Code Version -------9.19.0.2 0.0.0.0 9.19.0.2 9.19.0.2 When the failed unit resumes normal operation, the previous configuration that exists for that unit is reapplied by the stack master. To permanently remove the unit from the stack, enter into Stack Config Mode and use the member command, as the following example shows. console#configure console(config)#stack console(config-stack)#no member 2 console(config-stack)#exit console(config)#exit console#show switch SW Management Status Standby Preconfig Plugged- Switch Status Model ID in Model Status ID --- --------------- -------- ------------------1 Stack Member PCT7048 PCT7048 OK 3 Mgmt Switch PCT7048 PCT7048 OK 4 Stack Member PCT7048 PCT7048 OK Managing a Switch Stack Code Version -------9.19.0.2 9.19.0.2 9.19.0.2 165 Preconfiguring a Stack Member To preconfigure a stack member before connecting the physical unit to the stack, use the show support switchtype command to obtain the SID of the unit to be added. The example in this section demonstrates pre-configuring a PowerConnect 7048P switch on a stand-alone PowerConnect 7048R switch. To configure the switch: 1 View the list of SIDs to determine which SID identifies the switch to preconfigure. console#show supported switchtype SID -----1 2 3 4 5 6 7 8 Switch Mode ID Code Type ------------------------- ---------PCM6348 0x100b000 PCT7024 0x100b000 PCT7024P 0x100b000 PCT7024F 0x100b000 PCT7048 0x100b000 PCT7048P 0x100b000 PCT7048R 0x100b000 PCT7048R-RA 0x100b000 2 Preconfigure the 7048P switch (SID = 6) as member number 2 in the stack. console#configure console(config)#stack console(config-stack)#member 2 6 console(config-stack)#exit console(config)#exit 166 Managing a Switch Stack 3 Confirm the stack configuration. Some of the fields have been omitted from the following output due to space limitations. console#show switch SW Management Standby Status Status --- --------- ------1 Mgmt Sw 2 Unassigned Preconfig Plugged-in Model ID Model ID -------- --------PCT7048R PCT7048R PCT7048P Switch Code Status Version ---------- -------OK M.10.2 Not Present 0.0.0.0 Managing a Switch Stack 167 NSF in the Data Center Figure 8-12 illustrates a data center scenario, where the stack of two PowerConnect switches acts as an access switch. The access switch is connected to two aggregation switches, AS1 and AS2. The stack has a link from two different units to each aggregation switch, with each pair of links grouped together in a LAG. The two LAGs and link between AS1 and AS2 are members of the same VLAN. Spanning tree is enabled on the VLAN. Assume spanning tree selects AS1 as the root bridge. Assume the LAG to AS1 is the root port on the stack and the LAG to AS2 is discarding. Unit 1 is the stack master. If unit 1 fails, the stack removes the Unit 1 link to AS1 from its LAG. The stack forwards outgoing packets through the Unit 2 link to AS1 during the failover. During the failover, the stack continues to send BPDUs and LAG PDUs on its links on Unit 2. The LAGs stay up (with one remaining link in each), and spanning tree on the aggregation switches does not see a topology change. Figure 8-12. Data Center Stack Topology 168 Managing a Switch Stack NSF and VoIP Figure 8-13 shows how NSF maintains existing voice calls during a stack master failure. Assume the top unit is the stack master. When the stack master fails, the call from phone A is immediately disconnected. The call from phone B continues. On the uplink, the forwarding plane removes the failed LAG member and continues using the remaining LAG member. If phone B has learned VLAN or priority parameters through LLDP-MED, it continues to use those parameters. The stack resumes sending LLDPDUs with MED TLVs once the control plane restarts. Phone B may miss an LLDPDU from the stack, but should not miss enough PDUs to revert its VLAN or priority, assuming the administrator has not reduced the LLDPDU interval or hold count. If phone B is receiving quality of service from policies installed in the hardware, those policies are retained across the stack master restart. Figure 8-13. NSF and VoIP Managing a Switch Stack 169 NSF and DHCP Snooping Figure 8-14 illustrates an L2 access switch running DHCP snooping. DHCP snooping only accepts DHCP server messages on ports configured as trusted ports. DHCP snooping listens to DHCP messages to build a bindings database that lists the IP address the DHCP server has assigned to each host. IP Source Guard (IPSG) uses the bindings database to filter data traffic in hardware based on source IP address and source MAC address. Dynamic ARP Inspection (DAI) uses the bindings database to verify that ARP messages contain a valid sender IP address and sender MAC address. DHCP snooping checkpoints its bindings database. Figure 8-14. NSF and DHCP Snooping If the stack master fails, all hosts connected to that unit lose network access until that unit reboots. The hardware on surviving units continues to enforce source filters IPSG installed prior to the failover. Valid hosts continue to communicate normally. During the failover, the hardware continues to drop data packets from unauthorized hosts so that security is not compromised. 170 Managing a Switch Stack If a host is in the middle of an exchange with the DHCP server when the failover occurs, the exchange is interrupted while the control plane restarts. When DHCP snooping is enabled, the hardware traps all DHCP packets to the CPU. The control plane drops these packets during the restart. The DHCP client and server retransmit their DHCP messages until the control plane has resumed operation and messages get through. Thus, DHCP snooping does not miss any new bindings during a failover. As DHCP snooping applies its checkpointed DHCP bindings, IPSG confirms the existence of the bindings with the hardware by reinstalling its source IP address filters. If Dynamic ARP Inspection is enabled on the access switch, the hardware traps ARP packets to the CPU on untrusted ports. During a restart, the control plane drops ARP packets. Thus, new traffic sessions may be briefly delayed until after the control plane restarts. If IPSG is enabled and a DHCP binding is not checkpointed to the backup unit before the failover, that host will not be able to send data packets until it renews its IP address lease with the DHCP server. NSF and the Storage Access Network Figure 8-15 illustrates a stack of three PowerConnect switches connecting two servers (iSCSI initiators) to a disk array (iSCSI targets). There are two iSCSI connections as follows: Session A: 10.1.1.10 to 10.1.1.3 Session B: 10.1.1.11 to 10.1.1.1 An iSCSI application running on the stack master (the top unit in the diagram) has installed priority filters to ensure that iSCSI traffic that is part of these two sessions receives priority treatment when forwarded in hardware. Managing a Switch Stack 171 Figure 8-15. NSF and a Storage Area Network When the stack master fails, session A drops. The initiator at 10.1.1.10 detects a link down on its primary NIC and attempts to reestablish the session on its backup NIC to a different IP address on the disk array. The hardware forwards the packets to establish this new session, but assuming the session is established before the control plane is restarted on the backup unit, the new session receives no priority treatment in the hardware. Session B remains established and fully functional throughout the restart and continues to receive priority treatment in the hardware. 172 Managing a Switch Stack NSF and Routed Access Figure 8-16 shows a stack of three units serving as an access router for a set of hosts. Two LAGs connect the stack to two aggregation routers. Each LAG is a member of a VLAN routing interface. The stack has OSPF and PIM adjacencies with each of the aggregation routers. The top unit in the stack is the stack master. Figure 8-16. NSF and Routed Access If the stack master fails, its link to the aggregation router is removed from the LAG. When the control plane restarts, both routing interfaces come back up by virtue of the LAGs coming up. OSPF sends grace LSAs to inform its OSPF neighbors (the aggregation routers) that it is going through a graceful restart. NOTE: The graceful restart feature for OSPF is disabled by default. For information about the web pages and commands to configure NSF for OSPF or OSPFv3, see "Configuring OSPF and OSPFv3" on page 931. The grace LSAs reach the neighbors before they drop their adjacencies with the access router. PIM starts sending hello messages to its neighbors on the aggregation routers using a new generation ID to prompt the neighbors to quickly resend multicast routing information. PIM neighbors recognize the new generation ID and immediately relay the group state back to the restarting router. IGMP sends queries to relearn the hosts' interest in multicast groups. IGMP tells PIM the group membership, and PIM sends Managing a Switch Stack 173 JOIN messages upstream. The control plane updates the driver with checkpointed unicast routes. The forwarding plane reconciles L3 hardware tables. The OSPF graceful restart finishes, and the control plane deletes any stale unicast routes not relearned at this point. The forwarding plane reconciles L3 multicast hardware tables. Throughout the process, the hosts continue to receive their multicast streams, possibly with a short interruption as the top aggregation router learns that one of its LAG members is down. The hosts see no more than a 50 ms interruption in unicast connectivity. 174 Managing a Switch Stack Configuring Authentication, Authorization, and Accounting 9 This chapter describes how to control access to the switch management interface using authentication and authorization. It also describes how to record this access using accounting. Together the three services are referred to by the acronym AAA. The topics covered in this chapter include: • AAA Overview • Authentication • Authorization • Accounting • Authentication Examples • Authorization Examples • Using RADIUS Servers to Control Management Access • Using TACACS+ Servers to Control Management Access • Default Configurations AAA Overview AAA is a framework for configuring management security in a consistent way. Three services make up AAA: • Authentication—Validates the user identity. Authentication takes place before the user is allowed access to switch services. • Authorization—Determines which services the user is allowed to access. • Accounting—Collects and sends security information about users and commands. Configuring Authentication, Authorization, and Accounting Each service is configured using method lists. The method lists define how each service is to be performed by specifying the methods available to perform a service. The first method in a list is tried first. If the first method returns an error, the next method in the list is tried. This continues until all methods in the list have been attempted. If no method can perform the service, then the service fails. A method may return an error due to lack of network access, misconfiguration of a server, and other reasons. If there is no error, the method returns success if the user is allowed access to the service and failure if the user is not. AAA gives the user flexibility in configuration by allowing different method lists to be assigned to different access lines. In this way, it is possible to configure different security requirements for the serial console than for telnet, for example. Methods A method performs the configured service. Not every method is available for every service. Some methods require a username and password and other methods only require a password. Table 9-1 summarizes the various methods: Table 9-1. AAA Methods Method Username? Password? Can Return an Error? enable no yes yes ias yes yes no line no yes yes local yes yes yes none no no no radius yes yes yes tacacs yes yes yes Methods that never return an error cannot be followed by any other methods in a method list. • 176 The enable method uses the enable password. If there is no enable password defined, then the enable method will return an error. Configuring Authentication, Authorization, and Accounting • The ias method is a special method that is only used for 802.1X. It uses an internal database (separate from the local user database) that acts like an 802.1X authentication server. This method never returns an error. It will always pass or deny a user. • The line method uses the password for the access line on which the user is accessing the switch. If there is no line password defined for the access line, then the line method will return an error. • The local method uses the local user database. If the user password does not match, then access is denied. This method returns an error if the user name is not present in the local user database. • The none method does not perform any service, but instead always returns a result as if the service had succeeded. This method never returns an error. • The radius and tacacs methods communicate with servers running the RADIUS and TACACS+ protocols, respectively. These methods can return an error if the switch is unable to contact the server. Access Lines There are five access lines: console, telnet, SSH, HTTP, and HTTPS. HTTP and HTTPS are not configured using AAA method lists. Instead, the authentication list for HTTP and HTTPS is configured directly (authorization and accounting are not supported). The default method lists for both the HTTP and HTTPS access lines consist of only the local method. Each of the other access lines may be assigned method lists independently for the AAA services. Authentication Authentication is the process of validating a user's identity. During the authentication process, only identity validation is done. There is no determination made of which switch services the user is allowed to access. This is true even when RADIUS is used for authentication; RADIUS cannot perform separate transactions for authentication and authorization. However, the RADIUS server can provide attributes during the authentication process that are used in the authorization process. There are three types of authentication: Configuring Authentication, Authorization, and Accounting 177 • Login— Login authentication grants access to the switch if the user credentials are validated. Access is granted only at privilege level one. • Enable—Enable authentication grants access to a higher privilege level if the user credentials are validated for the higher privilege level. When RADIUS is used for enable authentication, the username for this request is always $enab15$. The username used to log into the switch is not used for RADIUS enable authentication. • dot1x—Dot1x authentication is used to grant an 802.1X supplicant access to the network. For more information about 802.1X, see "Configuring Port and System Security" on page 481. Table 9-2 shows the valid methods for each type of authentication: Table 9-2. Valid Methods for Authentication Types Method Login Enable dot1x enable yes yes no ias no no yes line yes yes no local yes no no none yes yes yes radius yes yes yes tacacs yes yes no Authorization Authorization is used to determine which services the user is allowed to access. For example, the authorization process may assign a user’s privilege level, which determines the set of commands the user can execute. There are three kinds of authorization: commands, exec, and network. 178 • Commands: Command authorization determines which CLI commands the user is authorized to execute. • Exec: Exec authorization determines what the user is authorized to do on the switch; that is, the user’s privilege level and an administrative profile. Configuring Authentication, Authorization, and Accounting • Network: Network authorization enables a RADIUS server to assign a particular 802.1X supplicant to a VLAN. For more information about 802.1X, see "Configuring Port and System Security" on page 481. Table 9-3 shows the valid methods for each type of authorization: Table 9-3. Authorization Methods Method Commands Exec Network local no yes no none yes yes no radius no yes yes tacacs yes yes no Exec Authorization Capabilities PowerConnect switches support two types of service configuration with exec authorization: privilege level and administrative profiles. Privilege Level By setting the privilege level during exec authorization, a user can be placed directly into Privileged EXEC mode when they log into the command line interface. Administrative Profiles The Administrative Profiles feature allows the network administrator to define a list of rules that control the CLI commands available to a user. These rules are collected in a “profile.” The rules in a profile can define the set of commands, or a command mode, to which a user is permitted or denied access. Within a profile, rule numbers determine the order in which the rules are applied. When a user enters a CLI command, rules within the first profile assigned to the user are applied in descending order until there is a rule that matches the input. If no rule permitting the command is found, then the other profiles assigned to the user (if any) are searched for rules permitting the command. Rules may use regular expressions for command matching. All Configuring Authentication, Authorization, and Accounting 179 profiles have an implicit “deny all” rule, such that any command that does not match any rule in the profile is considered to have been denied by that profile. A user can be assigned to more than one profile. If there are conflicting rules in profiles, the “permit” rule always takes precedence over the “deny” rule. That is, if any profile assigned to a user permits a command, then the user is permitted access to that command. A user may be assigned up to 16 profiles. A number of profiles are provided by default. These profiles cannot be altered by the switch administrator. See "Administrative Profiles" on page 198 for the list of default profiles. If the successful authorization method does not provide an administrative profile for a user, then the user is permitted access based upon the user's privilege level. This means that, if a user successfully passes enable authentication or if exec authorization assigns a privilege level, the user is permitted access to all commands. This is also true if none of the administrative profiles provided are configured on the switch. If some, but not all, of the profiles provided in the authentication are configured on the switch, then the user is assigned the profiles that exist, and a message is logged that indicates which profiles could not be assigned. Accounting Accounting is used to record security events, such as a user logging in or executing a command. Accounting records may be sent upon completion of an event (stop-only) or at both the beginning and end of an event (startstop). There are three types of accounting: commands, dot1x, and exec. • Commands—Sends accounting records for command execution. • Dot1x—Sends accounting records for network access. • Exec—Sends accounting records for management access (logins). For more information about the data sent in accounting records, see "Which RADIUS Attributes Does the Switch Support?" on page 192 and "Using TACACS+ Servers to Control Management Access" on page 195. Table 9-4 shows the valid methods for each type of accounting: 180 Configuring Authentication, Authorization, and Accounting Table 9-4. Accounting Methods Method Commands Dot1x Exec radius no yes yes tacacs yes no yes Authentication Examples It is important to understand that during authentication, all that happens is that the user is validated. If any attributes are returned from the server, they are not processed during authentication. In the examples below, it is assumed that the default configuration of authorization—that is, no authorization—is used. Local Authentication Example Use the following configuration to require local authentication when logging in over a telnet connection: aaa authentication login “loc” local line telnet login authentication loc exit username guest password password passwords strength minimum numeric-characters 2 passwords strength minimum character-classes 4 passwords strength-check username admin password paSS1&word2 privilege 15 passwords lock-out 3 The following describes each line of this code: • The aaa authentication login “loc” local command creates a login authentication list called “loc” that contains the method local. • The line telnet command enters the configuration mode for the telnet line. • The login authentication loc command assigns the loc login authentication list to be used for users accessing the switch via telnet. Configuring Authentication, Authorization, and Accounting 181 • The username guest password password command creates a user with the name “guest” and password “password”. A simple password can be configured here, since strength-checking has not yet been enabled. • The passwords strength minimum numeric-characters 2 command sets the minimum number of numeric characters required when password strength checking is enabled. This parameter is enabled only if the passwords strength minimum character-classes parameter is set to something greater than its default value of 0. • The passwords strength minimum character-classes 4 command sets the minimum number of character classes that must be present in the password. The possible character classes are: upper-case, lower-case, numeric and special. • The passwords strength-check command enables password strength checking. • The username admin password paSS1&word2 privilege 15 command creates a user with the name “admin” and password “paSS1&word2”. This user is enabled for privilege level 15. Note that, because password strength checking was enabled, the password was required to have at least two numeric characters, one uppercase character, one lowercase character, and one special character. • The passwords lock-out 3 command locks out a local user after three failed login attempts. This configuration allows either user to log into the switch. Both users will have privilege level 1. Neither user will be able to successfully execute the enable command, which grants access to Privileged EXEC mode, because there is no enable password set by default (the default method list for telnet enable authentication is only the “enable” method). NOTE: It is recommend that the password strength checking and password lockout features be enabled when using local users. TACACS+ Authentication Example Use the following configuration to require TACACS+ authentication when logging in over a telnet connection: aaa authentication login “tacplus” tacacs 182 Configuring Authentication, Authorization, and Accounting aaa authentication enable “tacp” tacacs-server host 1.2.3.4 key “secret” exit line telnet login authentication tacplus enable authentication tacp exit The following describes each line in the above configuration: • The aaa authentication login “tacplus” tacacs command creates a login authentication list called “tacplus” that contains the method tacacs. If this method returns an error, the user will fail to login. • The aaa authentication enable “tacp” tacacs command creates an enable authentication list called “tacp” that contains the method tacacs. If this method fails, then the user will fail to execute the enable command. • The tacacs-server host 1.2.3.4 command is the first step in defining a TACACS+ server at IP address 1.2.3.4. The result of this command is to place the user in tacacs-server mode to allow further configuration of the server. • The key “secret” command defines the shared secret. This must be the same as the shared secret defined on the TACACS+ server. • The line telnet command enters the configuration mode for the telnet line. • The login authentication tacplus command assigns the tacplus login authentication method list to be used for users accessing the switch via telnet. • The enable authentication tacp command assigns the tacp enable authentication method list to be used for users executing the enable command when accessing the switch via telnet. NOTE: A user logging in with this configuration would be placed in User EXEC mode with privilege level 1. To access Privileged EXEC mode with privilege level 15, use the enable command. Configuring Authentication, Authorization, and Accounting 183 RADIUS Authentication Example Use the following configuration to require RADIUS authentication to login over a telnet connection: aaa authentication login “rad” radius aaa authentication enable “raden” radius radius-server host 1.2.3.4 key “secret” exit line telnet login authentication rad enable authentication raden exit The following describes each line in the above configuration: 184 • The aaa authentication login “rad” radius command creates a login authentication list called “rad” that contains the method radius. If this method returns an error, the user will fail to login. • The aaa authentication enable “raden” radius command creates an enable authentication list called “raden” that contains the method radius. If this method fails, then the user will fail to execute the enable command. • The radius-server host 1.2.3.4 command is the first step in defining a RADIUS server at IP address 1.2.3.4. The result of this command is to place the user in radius-server mode to allow further configuration of the server. • The key “secret” command defines the shared secret. This must be the same as the shared secret defined on the RADIUS server. • The line telnet command enters the configuration mode for the telnet line. • The login authentication rad command assigns the rad login authentication method list to be used for users accessing the switch via telnet. • The enable authentication raden command assigns the raden enable authentication method list to be used for users executing the enable command when accessing the switch via telnet. Configuring Authentication, Authorization, and Accounting Authorization Examples Authorization allows the administrator to control which services a user is allowed to access. Some of the things that can be controlled with authorization include the user's initial privilege level and which commands the user is allowed to execute. When authorization fails, the user is denied access to the switch, even though the user has passed authentication. The following examples assume that the configuration used in the previous examples has already been applied. Local Authorization Example—Direct Login to Privileged EXEC Mode Apply the following configuration to use the local user database for authorization, such that a user can enter privileged EXEC mode directly: aaa authorization exec “locex” local line telnet authorization exec locex exit With the users that were previously configured, the guest user will still log into user EXEC mode, since the guest user only has privilege level 1 (the default). The admin user will be able to login directly to privileged EXEC mode since his privilege level was configured as 15. TACACS+ Authorization Example—Direct Login to Privileged EXEC Mode Apply the following configuration to use TACACS+ for authorization, such that a user can enter privileged EXEC mode directly: aaa authorization exec “tacex” tacacs line telnet authorization exec tacex exit Configure the TACACS+ server so that the shell service is enabled and the priv-lvl attribute is sent when user authorization is performed. For example: shell:priv-lvl=15 The following describes each line in the above configuration: Configuring Authentication, Authorization, and Accounting 185 • The aaa authorization exec “tacex” tacacs command creates an exec authorization method list called tacex which contains the method tacacs. • The authorization exec tacex command assigns the tacex exec authorization method list to be used for users accessing the switch via telnet. Notes: • If the privilege level is zero (that is, blocked), then authorization will fail and the user will be denied access to the switch. • If the privilege level is higher than one, the user will be placed directly in Privileged EXEC mode. Note that all commands in Privileged EXEC mode require privilege level 15, so assigning a user a lower privilege level will be of no value. • A privilege level greater than 15 is invalid and treated as if privilege level zero had been supplied. • The shell service must be enabled on the TACACS+ server. If this service is not enabled, authorization will fail and the user will be denied access to the switch. TACACS+ Authorization Example—Administrative Profiles The switch should use the same configuration as for the previous authorization example. The TACACS+ server should be configured such that it will send the “roles” attribute. For example: shell:roles=router-admin The above example attribute will give the user access to the commands permitted by the router-admin profile. NOTE: If the priv-lvl attribute is also supplied, the user can also be placed directly into privileged EXEC mode. 186 Configuring Authentication, Authorization, and Accounting TACACS+ Authorization Example—Custom Administrative Profile This example creates a custom profile that allows the user to control user access to the switch by configuring a administrative profile that only allows access to AAA related commands. Use the following commands to create the administrative profile: admin-profile aaa rule 99 permit command “^show aaa .*” rule 98 permit command “^show authentication .*” rule 97 permit command "^show authorization .*” rule 96 permit command “^show accounting .*” rule 95 permit command “^show tacacs .*” rule 94 permit command “^aaa .*” rule 93 permit command “^line .*” rule 92 permit command “^login .*” rule 91 permit command “^authorization .*” rule 90 permit command “^accounting .*” rule 89 permit command “^configure .*” rule 88 permit command “^password .*” rule 87 permit command “^username .*” rule 86 permit command “^show user.*" rule 85 permit command “^radius-server .*” rule 84 permit command “^tacacs-server .*” rule 83 permit mode radius-auth-config rule 82 permit mode radius-acct-config rule 81 permit mode tacacs-config exit The following describes each line in the above configuration: • The admin-profile aaa command will create an administrative profile call aaa and place the user in admin-profile-config mode. • Each rule number permit command regex command allows any command that matches the regular expression. • Each rule number permit mode mode-name command allows all commands in the named mode. • The command rules use regular expressions as implemented by Henry Spencer's regex library (the POSIX 1003.2 compliant version). In the regular expressions used in this example, the caret (^) matches the null Configuring Authentication, Authorization, and Accounting 187 string at the beginning of a line, the period (.) matches any single character, and the asterisk (*) repeats the previous match zero or more times. • To assign this profile to a user, configure the TACACS+ server so that it sends the following “roles” attribute for the user: shell:roles=aaa If it is desired to also permit the user access to network-operator commands (basically, all the command in User EXEC mode), then the “roles” attribute would be configured as follows: shell:roles=aaa,network-operator TACACS+ Authorization Example—Per-command Authorization An alternative method for command authorization is to use the TACACS+ feature of per-command authorization. With this feature, every time the user enters a command, a request is sent to the TACACS+ server to ask if the user is permitted to execute that command. Exec authorization does not need to be configured to use per-command authorization. Apply the following configuration to use TACACS+ to authorize commands: aaa authorization commands “taccmd” tacacs line telnet authorization commands taccmd exit The following describes each line in the above configuration: • The aaa authorization commands “taccmd” tacacs command creates a command authorization method list called taccmd that includes the method tacacs. • The authorization commands taccmd command assigns the taccmd command authorization method list to be used for users accessing the switch via telnet. The TACACS+ server must be configured with the commands that the user is allowed to execute. If the server is configured for command authorization as “None”, then no commands will be authorized. If both administrative 188 Configuring Authentication, Authorization, and Accounting profiles and per-command authorization are configured for a user, any command must be permitted by both the administrative profiles and by percommand authorization. RADIUS Authorization Example—Direct Login to Privileged EXEC Mode Apply the following configuration to use RADIUS for authorization, such that a user can enter privileged exec mode directly: aaa authorization exec “rad” radius line telnet authorization exec rad exit Configure the RADIUS server so that the RADIUS attribute Service Type (6) is sent with value Administrative. Any value other than Administrative is interpreted as privilege level 1. The following describes each line in the above configuration: • The aaa authorization exec “rad” radius command creates an exec authorization method list called “rad” that contains the method radius. • The authorization exec rad command assigns the rad exec authorization method list to be used for users accessing the switch via telnet. Notes: • If the privilege level is zero (that is, blocked), then authorization will fail and the user will be denied access to the switch. • If the privilege level is higher than one, the user will be placed directly in Privileged EXEC mode. Note that all commands in Privileged EXEC mode require privilege level 15, so assigning a user a lower privilege level will be of no value. • A privilege level greater than 15 is invalid and treated as if privilege level zero had been supplied. RADIUS Authorization Example—Administrative Profiles The switch should use the same configuration as in the previous authorization example. Configuring Authentication, Authorization, and Accounting 189 The RADIUS server should be configured such that it will send the Cisco AV Pair attribute with the “roles” value. For example: shell:roles=router-admin The above example attribute gives the user access to the commands permitted by the router-admin profile. Using RADIUS Servers to Control Management Access The RADIUS client on the switch supports multiple RADIUS servers. When multiple authentication servers are configured, they can help provide redundancy. One server can be designated as the primary and the other(s) will function as backup server(s). The switch attempts to use the primary server first. if the primary server does not respond, the switch attempts to use the backup servers. A priority value can be configured to determine the order in which the backup servers are contacted. How Does RADIUS Control Management Access? Many networks use a RADIUS server to maintain a centralized user database that contains per-user authentication information. RADIUS servers provide a centralized authentication method for: • Telnet Access • Web Access • Console to Switch Access • Access Control Port (802.1X) Like TACACS+, RADIUS access control utilizes a database of user information on a remote server. Making use of a single database of accessible information—as in an Authentication Server—can greatly simplify the authentication and management of users in a large network. One such type of Authentication Server supports the Remote Authentication Dial In User Service (RADIUS) protocol as defined by RFC 2865. For authenticating users prior to access, the RADIUS standard has become the protocol of choice by administrators of large accessible networks. To accomplish the authentication in a secure manner, the RADIUS client and RADIUS server must both be configured with the same shared password or 190 Configuring Authentication, Authorization, and Accounting “secret”. This “secret” is used to generate one-way encrypted authenticators that are present in all RADIUS packets. The “secret” is never transmitted over the network. RADIUS conforms to a secure communications client/server model using UDP as a transport protocol. It is extremely flexible, supporting a variety of methods to authenticate and statistically track users. RADIUS is also extensible, allowing for new methods of authentication to be added without disrupting existing functionality. As a user attempts to connect to the switch management interface, the switch first detects the contact and prompts the user for a name and password. The switch encrypts the supplied information, and a RADIUS client transports the request to a pre-configured RADIUS server. Figure 9-1. RADIUS Topology Backup RADIUS Server PowerConnect Switch Primary RADIUS Server Management Network ` Management Host The server can authenticate the user itself or make use of a back-end device to ascertain authenticity. In either case a response may or may not be forthcoming to the client. If the server accepts the user, it returns a positive result with attributes containing configuration information. If the server rejects the user, it returns a negative result. If the server rejects the client or the shared secrets differ, the server returns no result. If the server requires additional verification from the user, it returns a challenge, and the request process begins again. Configuring Authentication, Authorization, and Accounting 191 If you use a RADIUS server to authenticate users, you must configure user attributes in the user database on the RADIUS server. The user attributes include the user name, password, and privilege level. NOTE: To set the privilege level, it is recommended to use the Service-Type attribute instead of the Cisco AV pair priv-lvl attribute. Which RADIUS Attributes Does the Switch Support? Table 9-5 lists the RADIUS attributes that the switch supports and indicates whether the 802.1X feature, user management feature, or Captive Portal feature supports the attribute. You can configure these attributes on the RADIUS server(s) when utilizing the switch RADIUS service. Table 9-5. Supported RADIUS Attributes Type RADIUS Attribute Name 802.1X User Manager Captive Portal 1 USER-NAME Yes Yes No 2 USER-PASSWORD Yes Yes No 4 NAS-IP-ADDRESS Yes No No 5 NAS-PORT Yes Yes No 6 SERVICE-TYPE No Yes No 11 FILTER-ID Yes No No 12 FRAMED-MTU Yes No No 15 LOGIN-SERVICE No Yes 18 REPLY-MESSAGE Yes Yes No 24 STATE Yes Yes No 25 CLASS Yes No No 26 VENDOR-SPECIFIC No Yes Yes 27 SESSION-TIMEOUT Yes No Yes 28 IDLE-TIMEOUT No No Yes 29 TERMINATION-ACTION Yes No No 30 CALLED-STATION-ID Yes No No 192 Configuring Authentication, Authorization, and Accounting Table 9-5. Supported RADIUS Attributes (Continued) Type RADIUS Attribute Name 802.1X User Manager Captive Portal 31 CALLING-STATION-ID Yes No No 32 NAS-IDENTIFIER Yes Yes No 40 ACCT-STATUS-TYPE Set by RADIUS client for Accounting Yes No 42 ACCT-INPUT-OCTETS Yes No No 43 ACCT-OUTPUT-OCTETS Yes No No 44 ACCT-SESSION-ID Set by RADIUS client for Accounting Yes No 46 ACCT-SESSION-TIME Yes Yes No 49 ACCT-TERMINATECAUSE Yes No No 52 ACCTINPUTGIGAWORDS Yes No No 53 ACCTOUTPUTGIGAWORDS Yes No No 61 NAS-PORT-TYPE Yes No No 64 TUNNEL-TYPE Yes No No 65 TUNNEL-MEDIUM-TYPE Yes No No 79 EAP-MESSAGE Yes No No 80 MESSAGEAUTHENTICAT Set by OR RADIUS client for Accounting Yes No 81 TUNNELPRIVATEGROUP-ID No No Yes Configuring Authentication, Authorization, and Accounting 193 How Are RADIUS Attributes Processed on the Switch? The following attributes are processed in the RADIUS Access-Accept message received from a RADIUS server: 194 • NAS-PORT—ifIndex of the port to be authenticated. • REPLY-MESSAGE—Trigger to respond to the Access-Accept message with an EAP notification. • STATE-RADIUS—Server state. Transmitted in Access-Request and Accounting-Request messages. • SESSION-TIMEOUT—Session timeout value for the session (in seconds). Used by both 802.1x and Captive Portal. • TERMINATION-ACTION—Indication as to the action taken when the service is completed. • EAP-MESSAGE—Contains an EAP message to be sent to the user. This is typically used for MAB clients. • VENDOR-SPECIFIC—The following Cisco AV Pairs are supported: – shell:priv-lvl – shell:roles • FILTER-ID—Name of the filter list for this user. • TUNNEL-TYPE—Used to indicate that a VLAN is to be assigned to the user when set to tunnel type VLAN (13). • TUNNEL-MEDIUM-TYPE—Used to indicate the tunnel medium type. Must be set to medium type 802 (6) to enable VLAN assignment. • TUNNEL-PRIVATE-GROUP-ID—Used to indicate the VLAN to be assigned to the user. May be a string which matches a preconfigured VLAN name or a VLAN id. If a VLAN id is given, the string must only contain decimal digits. Configuring Authentication, Authorization, and Accounting Using TACACS+ Servers to Control Management Access TACACS+ (Terminal Access Controller Access Control System) provides access control for networked devices via one or more centralized servers. TACACS+ simplifies authentication by making use of a single database that can be shared by many clients on a large network. TACACS+ uses TCP to ensure reliable delivery and a shared key configured on the client and daemon server to encrypt all messages. If you configure TACACS+ as the authentication method for user login and a user attempts to access the user interface on the switch, the switch prompts for the user login credentials and requests services from the TACACS+ client. The client then uses the configured list of servers for authentication, and provides results back to the switch. Figure 9-2 shows an example of access management using TACACS+. Figure 9-2. Basic TACACS+ Topology Backup TACACS+ Server PowerConnect Switch Primary TACACS+ Server Management Network ` Management Host You can configure the TACACS+ server list with one or more hosts defined via their network IP address. You can also assign each a priority to determine the order in which the TACACS+ client will contact them. TACACS+ contacts the server when a connection attempt fails or times out for a higher priority server. Configuring Authentication, Authorization, and Accounting 195 You can configure each server host with a specific connection type, port, timeout, and shared key, or you can use global configuration for the key and timeout. The TACACS+ server can do the authentication itself, or redirect the request to another back-end device. All sensitive information is encrypted and the shared secret is never passed over the network; it is used only to encrypt the data. Which TACACS+ Attributes Does the Switch Support? Table 9-6 lists the TACACS+ attributes that the switch supports and indicates whether the authorization or accounting service supports sending or receiving the attribute. The authentication service does not use attributes. You can configure these attributes on the TACACS+ server(s) when utilizing the switch TACACS+ service. Table 9-6. Supported TACACS+ Attributes Attribute Name Exec Authorization Command Authorization Accounting cmd both (optional) sent sent cmd-arg sent elapsed-time priv-lvl sent received protocol sent roles both (optional) service=shell both sent sent start-time sent stop-time sent 196 Configuring Authentication, Authorization, and Accounting Default Configurations Method Lists The method lists shown in Table 9-7 are defined by default. They cannot be deleted, but they can be modified. Using the “no” command on these lists will return them to their default configuration. Table 9-7. Default Method Lists AAA Service (type) List Name List Methods Authentication (login) defaultList none Authentication (login) networkList local Authentication (enable) enableList enable none Authentication (enable) enableNetList enable Authorization (exec) dfltExecAuthList none Authorization (commands) dfltCmdAuthList none Accounting (exec) dfltExecList tacacs (start-stop) Accounting (commands) dfltCmdList tacacs (stop-only) Access Lines (AAA) Table 9-8 shows the method lists assigned to the various access lines by default. Table 9-8. Default AAA Methods AAA Service (type) Console Telnet SSH Authentication (login) defaultList networkList networkList Authentication (enable) enableList enableNetList enableNetList Authorization (exec) dfltExecAuthList dfltExecAuthList dfltExecAuthList Authorization (commands) dfltCmdAuthList dfltCmdAuthList dfltCmdAuthList Configuring Authentication, Authorization, and Accounting 197 Table 9-8. Default AAA Methods (Continued) AAA Service (type) Console Telnet SSH Accounting (exec) none none none Accounting (commands) none none none Access Lines (Non-AAA) Table 9-9 shows the default configuration of the access lines that do not use method lists. Table 9-9. Default Configuration for Non-AAA Access Lines Access Line Authentication Authorization HTTP local n/a HTTPS local n/a 802.1X none none Administrative Profiles The administrative profiles shown in Table 9-10 are system-defined and may not be deleted or altered. To see the rules in a profile, use the show adminprofiles name profile name command. Table 9-10. Default Administrative Profiles Name Description network-admin Allows access to all commands. network-security Allows access to network security features such as 802.1X, Voice VLAN, Dynamic ARP Inspection and IP Source Guard. router-admin Allows access to Layer 3 features such as IPv4 Routing, IPv6 Routing, OSPF, RIP, etc. multicast-admin Allows access to multicast features at all layers, this includes L2, IPv4 and IPv6 multicast, IGMP, IGMP Snooping, etc. dhcp-admin Allows access to DHCP related features such as DHCP Server and DHCP Snooping. 198 Configuring Authentication, Authorization, and Accounting Table 9-10. Default Administrative Profiles (Continued) Name Description CP-admin Allows access to the Captive Portal feature. network-operator Allows access to all User EXEC mode commands and show commands. Configuring Authentication, Authorization, and Accounting 199 200 Configuring Authentication, Authorization, and Accounting 10 Monitoring and Logging System Information This chapter provides information about the features you use to monitor the switch, including logging, cable tests, and email alerting. The topics covered in this chapter include: • System Monitoring Overview • Default Log Settings • Monitoring System Information and Configuring Logging (Web) • Monitoring System Information and Configuring Logging (CLI) • Logging Configuration Examples System Monitoring Overview What System Information Is Monitored? The CLI and web-based interfaces provide information about physical aspects of the switch, such as system health and cable diagnostics, as well as information about system events, such as management login history. The switch also reports system resource usage. The system logging utility can monitor a variety of events, including the following: • System events — System state changes and errors that range in severity from Emergency to Debug • Audit events — Attempts to login or logout from the switch and attempts to perform any operations with files on the flash drive • CLI commands — Commands executed from the CLI • Web page visits — Pages viewed by using OpenManage Switch Administrator • SNMP events — SNMP set operations Monitoring and Logging System Information 201 Why Is System Information Needed? The information the switch provides can help you troubleshoot issues that might be affecting system performance. The cable diagnostics test help you troubleshoot problems with the physical connections to the switch. Auditing access to the switch and the activities an administrator performed while managing the switch can help provide security and accountability. Where Are Log Messages Sent? The messages the switch generates in response to events, faults, errors, and configuration changes can be recorded in several locations. By default, these messages are stored locally on the switch in the RAM (cache). This collection of log files is called the RAM log or buffered log. When the RAM log file reaches the configured maximum size, the oldest message is deleted from the RAM when a new message is added. If the system restarts, all messages are cleared. In addition to the RAM log, you can specify that log files are sent to the following sources: 202 • Console — If you are connected to the switch CLI through the console port, messages display to the screen as they are generated. Use the terminal monitor command to control logging of messages to the console when connected via Telnet or SSH. • Log file — Messages sent to the log file are saved in the flash memory and are not cleared when the system restarts. • Remote server — Messages can be sent to a remote log server for viewing and storage. • Email — Messages can be sent to one or more email addresses. You must configure information about the network Simple Mail Transport Protocol SMTP) server for email to be successfully sent from the switch. Monitoring and Logging System Information What Are the Severity Levels? For each local or remote log file, you can specify the severity of the messages to log. Each severity level is identified by a name and a number. Table 10-1 provides information about the severity levels. Table 10-1. Log Message Severity Severity Keyword Severity Level Description emergencies 0 The switch is unusable. alerts 1 Action must be taken immediately. critical 2 The switch is experiencing critical conditions. errors 3 The switch is experiencing error conditions. warnings 4 The switch is experiencing warning conditions. notification 5 The switch is experiencing normal but significant conditions. informational 6 The switch is providing non-critical information. debugging 7 The switch is providing debug-level information. When you specify the severity level, messages with that severity level and higher are sent to the log file. For example, if you specify the severity level as critical, messages with a severity level of alert and emergency are also logged. When you specify the severity level in a CLI command, you can use the keyword or the numerical level. What Are the System Startup and Operation Logs? Two types of log files exist in flash (persistent) memory: • The first log type is the system startup log. The system startup log stores the first 32 messages received after system reboot. The log file stops when it is full. • The second log type is the system operation log. The system operation log stores the last 1000 messages received during system operation. The oldest messages are overwritten when the file is full. A message is only logged in one file. On system startup, if the Log file is enabled, the startup log stores messages up to its limit. Then the operation log begins to store the messages. Monitoring and Logging System Information 203 To view the log messages in the system startup and operational log files, you must download the log files to an administrative host. The startup log files are named slogX.txt and the operation log files are named ologX.txt. When enabled, the system stores the startup and operation log files for the last three switch boots. The current log files have a zero (0) in the file name (replacing the X in the name as shown above), the prior log files contain a one (1) in the name, and the oldest log files contain a two (2) in the name. For more information about downloading files, see "Managing Images and Files" on page 319. What Is the Log Message Format? The first part of the log message up to the first left bracket is fixed by the Syslog standard (RFC 3164). The second part up to the two percent signs is standardized for all Dell PowerConnect logs. The variable text of the log message follows. The log message is limited to 96 bytes. Each log message uses the following format: 204 • PRI—This consists of the facility code (see RFC 3164) multiplied by 8 and added to the severity. The log messages use the local7 facility code (23). This implies that a message of severity 0 will have a priority of 184 and a message of severity 7 will have a priority of 191. • Timestamp—This is the system up time. For systems that use SNTP, this is UTC. When time zones are enabled, local time will be used. • Host IP address—This is the IP address of the local system. Monitoring and Logging System Information • Stack ID —This is the assigned stack ID. The number 1 is used for systems without stacking ability. The top of stack is used to collect messages for the entire stack. • Component name—The component name for the logging component. Component “UNKN” is substituted for components that do not identify themselves to the logging component. • Thread ID—The thread ID of the logging component. • File name —The name of the file containing the invoking macro. • Line number —The line number which contains the invoking macro. • Sequence number —The message sequence number for this stack component. Sequence numbers may be skipped because of filtering but are always monotonically increasing on a per-stack member basis. • Message — Contains the text of the log message. What Factors Should Be Considered When Configuring Logging? Dell recommends that network administrators deploy a syslog server in their network and configure all switches to log messages to the syslog server. Switch administrators should also consider enabling persistent logging on the switch. When managing logs on a stack of switches, the RAM log and persistent log files exist only on the top of stack platform. Other platforms in the stack forward their messages to the top of stack log. Default Log Settings System logging is enabled, and messages are sent to the console (severity level: warning and above), and RAM log (severity level: informational and above). Switch auditing, CLI command logging, Web logging, and SNMP logging are disabled. By default, no messages are sent to the log file that is stored in flash, and no remote log servers are defined. Email alerting is disabled, and no recipient email address is configured. Additionally, no mail server is defined. If you add a mail server, by default, no authentication or security protocols are configured, and the switch uses TCP port 25 for SMTP. Monitoring and Logging System Information 205 After you enable email alerting and configure the mail server and recipient email address, log messages with a severity level of emergency and alert are sent immediately with each log message in a separate mail. The email subject is “Urgent Log Messages.” Log messages with a severity level of critical, error, and warning are sent periodically in a single email. The email subject is “Non Urgent Log Messages.” Messages with a severity level of notice and below are not sent in an email. 206 Monitoring and Logging System Information Monitoring System Information and Configuring Logging (Web) This section provides information about the OpenManage Switch Administrator pages to use to monitor system information and configure logging on the PowerConnect 7000 Series switch. For details about the fields on a page, click at the top of the page. Device Information The Device Information page displays after you successfully log on to the switch by using the Dell OpenManage Switch Administrator. This page is a virtual representation of the switch front panel. Use the Device Information page to view information about the port status, system status, and the switch stack. Click on a port to access the Port Configuration page for the selected port. To display the Device Information page, click Home in the navigation panel. Figure 10-1. Device Information Click the Stack View link to view front panel representations for all units in the stack. Monitoring and Logging System Information 207 Figure 10-2. Stack View For more information about the device view features, see "Understanding the Device View" on page 108. 208 Monitoring and Logging System Information System Health Use the Health page to view status information about the switch power and ventilation sources. To display the Health page, click System → General → Health in the navigation panel. Figure 10-3. Health Monitoring and Logging System Information 209 System Resources Use the System Resources page to view information about memory usage and task utilization. To display the System Resources page, click System → General → System Resources in the navigation panel. Figure 10-4. System Resources 210 Monitoring and Logging System Information Unit Power Usage History Use the Unit Power Usage History page to view information about switch power consumption. To display the Unit Power Usage History page, click System → General → Unit Power Usage History in the navigation panel. Figure 10-5. Unit Power Usage History Monitoring and Logging System Information 211 Integrated Cable Test for Copper Cables Use the Integrated Cable Test for Copper Cables page to perform tests on copper cables. Cable testing provides information about where errors occurred in the cable, the last time a cable test was performed, and the type of cable error which occurred. The tests use Time Domain Reflectometry (TDR) technology to test the quality and characteristics of a copper cable attached to a port. Cables up to 120 meters long can be tested. Cables are tested when the ports are in the down state, with the exception of the Approximated Cable Length test. SFP, SFP+, and QSFP cables with passive copper assemblies are not capable of performing TDR tests. NOTE: Cable diagnostics may give misleading results if any green Ethernet modes are enabled on the port. Disable EEE or energy-detect mode prior to running any cable diagnostics. To display the Integrated Cable Test for Copper Cables page, click System → Diagnostics → Integrated Cable Test in the navigation panel. Figure 10-6. Integrated Cable Test for Copper Cables 212 Monitoring and Logging System Information To view a summary of all integrated cable tests performed, click the Show All link. Figure 10-7. Integrated Cable Test Summary Optical Transceiver Diagnostics Use the Optical Transceiver Diagnostics page to perform tests on Fiber Optic cables. To display the Optical Transceiver Diagnostics page, click System → Diagnostics → Optical Transceiver Diagnostics in the navigation panel. NOTE: Optical transceiver diagnostics can be performed only when the link is present. Monitoring and Logging System Information 213 Figure 10-8. Optical Transceiver Diagnostics To view a summary of all optical transceiver diagnostics tests performed, click the Show All link. Figure 10-9. Optical Transceiver Diagnostics Summary 214 Monitoring and Logging System Information Log Global Settings Use the Global Settings page to enable logging globally, to enable other types of logging. You can also specify the severity of messages that are logged to the console, RAM log, and flash-based log file. The Severity table lists log messages from the highest severity (Emergency) to the lowest (Debug). When you select a severity level, all higher levels are automatically selected. To prevent log messages from being sent to the console, RAM log, or flash log file, clear all check boxes in the Severity column. To display the Global Settings page, click System → Logs → Global Settings in the navigation panel. Figure 10-10. Global Settings Monitoring and Logging System Information 215 RAM Log Use the RAM Log page to view information about specific RAM (cache) log entries, including the time the log was entered, the log severity, and a description of the log. To display the RAM Log, click System → Logs → RAM Log in the navigation panel. Figure 10-11. 216 RAM Log Table Monitoring and Logging System Information Log File The Log File contains information about specific log entries, including the time the log was entered, the log severity, and a description of the log. To display the Log File, click System → Logs → Log File in the navigation panel. Figure 10-12. Log File Remote Log Server Use the Remote Log Server page to view and configure the available log servers, to define new log servers, and to set the severity of the log events sent to the server. To display the Remote Log Server page, click System → Logs → Remote Log Server. Monitoring and Logging System Information 217 Figure 10-13. Remote Log Server Adding a New Remote Log Server To add a log server: 1 Open the Remote Log Server page. 2 Click Add to display the Add Remote Log Server page. 3 Specify the IP address or hostname of the remote server. 4 Define the UDP Port and Description fields. 218 Monitoring and Logging System Information Figure 10-14. Add Remote Log Server 5 Select the severity of the messages to send to the remote server. NOTE: When you select a severity level, all higher severity levels are automatically selected. 6 Click Apply. Click the Show All link to view or remove remote log servers configured on the system. Monitoring and Logging System Information 219 Figure 10-15. Show All Log Servers Email Alert Global Configuration Use the Email Alert Global Configuration page to enable the email alerting feature and configure global settings so that system log messages can be sent to from the switch to one or more email accounts. To display the Email Alert Global Configuration page, click System → Email Alerts → Email Alert Global Configuration in the navigation panel. Figure 10-16. 220 Email Alert Global Configuration Monitoring and Logging System Information Email Alert Mail Server Configuration Use the Email Alert Mail Server Configuration page to configure information about the mail server the switch uses for sending email alert messages. To display the Email Alert Mail Server Configuration page, click System → Email Alerts → Email Alert Mail Server Configuration in the navigation panel. Figure 10-17. Email Alert Mail Server Configuration Adding a Mail Server To add a mail server: 1 Open the Email Alert Mail Server Configuration page. 2 Click Add to display the Email Alert Mail Server Add page. 3 Specify the hostname of the mail server. Monitoring and Logging System Information 221 Figure 10-18. Add Mail Server 4 Click Apply. 5 If desired, click Configuration to return to the Email Alert Mail Server Configuration page to specify port and security settings for the mail server. Click the Show All link to view or remove mail servers configured on the switch. Figure 10-19. 222 Show All Mali Servers Monitoring and Logging System Information Email Alert Subject Configuration Use the Email Alert Subject Configuration page to configure the subject line for email alerts that are sent by the switch. You can customize the subject for the message severity and entry status. To display the Email Alert Subject Configuration page, click System → Email Alerts → Email Alert Subject Configuration in the navigation panel. Figure 10-20. Email Alert Subject Configuration To view all configured email alert subjects, click the Show All link. Figure 10-21. View Email Alert Subjects Monitoring and Logging System Information 223 Email Alert To Address Configuration Use the Email Alert To Address Configuration page to specify where the email alerts are sent. You can configure multiple recipients and associate different message severity levels with different recipient addresses. To display the Email Alert To Address Configuration page, click System → Email Alerts → Email Alert To Address Configuration in the navigation panel. Figure 10-22. Email Alert To Address Configuration To view configured recipients, click the Show All link. Figure 10-23. 224 View Email Alert To Address Configuration Monitoring and Logging System Information Email Alert Statistics Use the Email Alert Statistics page to view the number of emails that were successfully and unsuccessfully sent, and when emails were sent. To display the Email Alert Statistics page, click System → Email Alerts → Email Alert Statistics in the navigation panel. Figure 10-24. Email Alert Statistics Monitoring and Logging System Information 225 Monitoring System Information and Configuring Logging (CLI) This section provides information about the commands you use to configure information you use to monitor the PowerConnect 7000 Series switch. For more information about these commands, see the PowerConnect 7000 Series CLI Reference Guide at support.dell.com/manuals. Viewing System Information and Enabling the Locator LED Beginning in Privileged EXEC mode, use the following commands to view system health and resource information and to enable the switch locator LED. Command Purpose show system Display various system information. show system power Displays the power supply status. show system temperature Displays the system temperature and fan status. show memory cpu Displays the total and available RAM space on the switch. show process cpu Displays the CPU utilization for each process currently running on the switch. locate [switch unit] [time time] Enable the switch locator LED located on the back panel of the switch. Optionally, you can specify the unit to identify within a switch stack and the length of time that the LED blinks. Running Cable Diagnostics Beginning in Privileged EXEC mode, use the following commands to run the cable diagnostic tests. NOTE: Cable diagnostics may give misleading results if green mode is enabled on the port. Disable green mode prior to running any cable diagnostics. 226 Monitoring and Logging System Information Command Purpose test copper-port tdr Perform the Time Domain Reflectometry (TDR) test to diagnose the quality and characteristics of a copper cable attached to the specified port. SFP, SFP+, and QSFP cables with passive copper assemblies are not capable of performing TDR tests. interface CAUTION: Issuing the test copper-port tdr command will bring the interface down. NOTE: To ensure accurate measurements, disable all Green Ethernet modes (EEE or energy-detect mode) on the port before running the test. The interface is specified in unit/slot/port format. For example 1/0/3 is GbE interface 3 on unit 1 of the stack. show copper-ports tdr [interface] Display the diagnostic information collected by the test copper-port tdr command for all copper interfaces or a specific interface. show fiber-ports optical- Display the optical transceiver diagnostics for all fiber ports. Include the interface option to show information for transceiver [interface] the specified port. Configuring Local Logging Beginning in Privileged EXEC mode, use the following commands to configure the type of messages that are logged and where the messages are logged locally. Command Purpose configure Enter Global Configuration mode. logging on Globally enables logging. logging audit Enable switch auditing. logging cli-command Enable CLI command logging logging web-sessions Enable logging of the switch management Web page visits. logging snmp Enable logging of SNMP set commands. Monitoring and Logging System Information 227 Command Purpose logging Enable logging to the specified file. Optionally, you can {buffered|console| file} define a logging discriminator to help filter log messages [severity] and set the severity of the messages to log. • buffered — Enables logging to the RAM file (cache). If the switch resets, the buffered logs are cleared. • console — Enables logging to the screen when you are connected to the CLI through the console port. • file — Enables logging to the startup and operational log files on the flash. • discriminator disc-name — (Optional) Include a message discriminator to help filter log messages. The disc-name can contain up to eight alphanumeric characters. Spaces are not permitted. • severity — (Optional) Enter the number or name of the desired severity level. For information about severity levels, see Table 10-1. logging facility facility- type Set the facility for logging messages. Permitted facilitytype values are local0, local1, local2, local3, local4, local5, CTRL + Z Exit to Privileged EXEC mode. show logging Displays the state of logging and the syslog messages stored in the internal buffer. show logging file View information about the flash (persistent) log file. clear logging Use to clear messages from the logging buffer. 228 local 6, local7 Monitoring and Logging System Information Configuring Remote Logging Beginning in Privileged EXEC mode, use the following commands to define a remote server to which the switch sends log messages. Command Purpose configure Enter Global Configuration mode. logging {ip-address| hostname} Define a remote log server and enter the configuration mode for the specified log server. description description Describe the log server. Use up to 64 characters. If the description includes spaces, surround it with quotation marks. level severity Specify the severity level of the logs that should be sent to the remote log server. For information about severity levels, see Table 10-1. port udp-port Specify the UDP port to use for sending log messages. The range is 1 to 65535, and the default is 514. CTRL + Z Exit to Privileged EXEC mode. show syslog-servers Verify the remote log server configuration. Monitoring and Logging System Information 229 Configuring Mail Server Settings Beginning in Privileged EXEC mode, use the following commands to configure information about the mail server (SMTP host) on the network that will initially receive the email alerts from the switch and relay them to the correct recipient. Command Purpose configure Enter Global Configuration mode. mail-server ip-address Specify the IP address of the SMTP server on the network and enter the configuration mode for the mail server. security {tlsvl|none} (Optional) Specify the security protocol to use with the mail server. port {25|465} Configure the TCP port to use for SMTP, which can be 25 (SMTP) or 465 (SMTP over SSL). username username If the SMTP server requires authentication, specify the username to use for the switch. The same username and password settings must be configured on the SMTP host. password password If the SMTP server requires authentication from clients, specify the password to associate with the switch username. CTRL + Z Exit to Privileged EXEC mode. show mail-server all config View mail server configuration information for all configured mail servers. 230 Monitoring and Logging System Information Configuring Email Alerts for Log Messages Beginning in Privileged EXEC mode, use the following commands to configure email alerts so that log messages are sent to the specified address. Command Purpose configure Enter Global Configuration mode. logging email [severity] Enable email alerting and determine which non-critical log messages should be emailed. Including the severity value sets the lowest severity for which log messages are emailed. These messages are collected and sent in a single email at the configured log duration. severity — (Optional) Enter the number or name of the severity level for non-critical messages. Log messages at or above this severity level are emailed. For information about severity levels, see Table 10-1. Log messages below the specified level are not emailed. logging email urgent {severity | none} Determine which log messages are critical and should be sent in a single email as soon as they are generated. severity — (Optional) Enter the number or name of the severity level for critical messages. For information about severity levels, see Table 10-1. logging email logtime Specify how often to send the non-critical email alerts that have been collected. . The valid range is 30 - 1440 minutes. logging email messagetype {urgent | nonurgent | both} to-addr Specify the email address of the recipient for log messages. minutes email-address logging email from-addr Specify the email address of the sender, which is the switch. email-address logging email messagetype {urgent | nonurgent | both} subject Specify the text that will appear in the subject line of email alerts sent by the switch. subject Monitoring and Logging System Information 231 Command Purpose logging email test message-type {urgent | non-urgent | both} message-body body Send a test email to the configured recipient to verify that the feature is properly configured. CTRL + Z Exit to Privileged EXEC mode. show logging email config View the configured settings for email alerts. show logging email statistics View information about the number of emails sent and the time they were sent. clear logging email statistics Clear the email alerting statistics. 232 Monitoring and Logging System Information Logging Configuration Examples This section contains the following examples: • Configuring Local and Remote Logging • Configuring Email Alerting Configuring Local and Remote Logging This example shows how to enable switch auditing and CLI command logging. Log messages with a severity level of Notification (level 5) and above are sent to the RAM (buffered) log. Emergency, Critical, and Alert (level 2) log messages are written to the log file on the flash drive. All log messages are displayed on the console and sent to a remote syslog server. To configure the switch: 1 Enable switch auditing and CLI command logging. console#configure console(config)#logging audit console(config)#logging cli-command 2 Specify where the logs are sent locally and what severity level of message is to be logged. You can specify the severity as the level number, as shown in the first two commands, or as the keyword, shown in the third command. console(config)#logging buffered 5 console(config)#logging file 2 console(config)#logging console debugging 3 Define the remote log server. console(config)#logging 192.168.2.10 console(Config-logging)#description "Syslog Server" console(Config-logging)#level debug console(Config-logging)#exit console(config)#exit Monitoring and Logging System Information 233 4 Verify the remote log server configuration. console#show syslog-servers IP Address/Hostname Port ------------------------- -----192.168.2.10 514 Severity Description -------------- ---------debugging Syslog Server 5 Verify the local logging configuration and view the log messages stored in the buffer (RAM log). console#show logging Logging is enabled Console Logging: level debugging. Console Messages: 748 Dropped. Buffer Logging: level notifications. Buffer Messages: 79 Logged, File Logging: level critical. File Messages: 973 Dropped. CLI Command Logging : enabled Switch Auditing : enabled Web Session Logging : disabled SNMP Set Command Logging : disabled Syslog server 192.168.2.10 logging: debug. Messages: 0 dropped 412 Messages dropped due to lack of resources. Buffer Log: <186> FEB 02 05:53:03 0.0.0.0-1 UNKN[1073741088]: bootos.c(232) 1 %% Event(0xaaaaaaaa) <189> FEB 02 05:53:03 0.0.0.0-1 UNKN[1073741088]: bootos.c(248) 2 %% Starting code... BSP initialization complete, starting application. --More-- or (q)uit Configuring Email Alerting The commands in this example define the SMTP server to use for sending email alerts. The mail server does not require authentication and uses the standard TCP port for SMTP, port 25, which are the default values. Only 234 Monitoring and Logging System Information Emergency messages (severity level 0) will be sent immediately as individual emails, and messages with a severity of alert, critical, and error (levels 1-3) will be sent in a single email every 120 minutes. Warning, notice, info, and debug messages are not sent in an email. The email the administrator will in the inbox has a format similar to the following: Figure 10-25. Email Alert Message Format For emergency-level messages, the subject is LOG MESSAGE EMERGENCY. For messages with a severity level of alert, critical, and error, the subject is LOG MESSAGE. To configure the switch: 1 Specify the mail server to use for sending messages. console#configure console(config)#mail-server ip-address 192.168.2.34 2 Configure the username and password for the switch must use to authenticate with the mail server. console(Mail-Server)#username switch7048 console(Mail-Server)#password password7048 console(Mail-Server)#exit Monitoring and Logging System Information 235 3 Configure emergencies and alerts to be sent immediately, and all other messages to be sent in a single email every 120 minutes. console(config)#logging email error console(config)#logging email urgent emergency console(config)#logging email logtime 120 4 Specify the email address of the sender (the switch). console(config)#logging email from-addr pc7048_noreply@dell.com 5 Specify the address where email alerts should be sent. console(config)#logging email message-type both to-addr administrator@dell.com 6 Specify the text that will appear in the email alert Subject line. console(config)#logging email message-type urgent subject "LOG MESSAGES - EMERGENCY" console(config)#logging email message-type nonurgent subject "LOG MESSAGES" 7 Verify the configuration. console#show mail-server all config Mail Servers Configuration: No of mail servers configured.................. 1 Email Email Email Email Email Alert Alert Alert Alert Alert Mail Server Address................ Mail Server Port................... SecurityProtocol................... Username........................... Password........................... 192.168.2.34 25 none switch7048 password7048 console#show logging email config Email Alert Logging............................ Email Alert From Address....................... pc7048_noreply@dell.com Email Alert Urgent Severity Level.............. Email Alert Non Urgent Severity Level.......... Email Alert Trap Severity Level................ Email Alert Notification Period................ 236 Monitoring and Logging System Information enabled 0 3 6 120 min Email Alert To Address Table: For Msg Type..........................1 Address1..............................administrator@dell.com For Msg Type..........................2 Address1..............................administrator@dell.com Email Alert Subject Table : For Msg Type 1, subject is............LOG MESSAGES - EMERGENCY For Msg Type 2, subject is............LOG MESSAGE Monitoring and Logging System Information 237 238 Monitoring and Logging System Information 11 Managing General System Settings This chapter describes how to set system information, such as the hostname, and time settings, and how to select the Switch Database Management (SDM) template to use on the switch. This chapter also describes how to view back-panel expansion slot information as well as how to configure the Power over Ethernet (PoE) settings for the PowerConnect 7024P and 7048P switches. The topics covered in this chapter include: • System Settings Overview • Default General System Information • Configuring General System Settings (Web) • Configuring System Settings (CLI) • General System Settings Configuration Examples System Settings Overview The system settings include the information described in Table 11-1. This information helps identify the switch. Table 11-1. System Information Feature Description System Name The switch name (host name). If you change the system name, the CLI prompt changes from console to the system name. System contact Identifies the person to contact for information regarding the switch. System location Identifies the physical location of the switch. Asset tag Uniquely identifies the switch. Some organizations use asset tags to identify, control, and track each piece of equipment. CLI Banner Displays a message upon connecting to the switch or logging on to the switch by using the CLI. Managing General System Settings 239 Table 11-1. System Information Feature Description SDM Template Determines the maximum resources a switch or router can use for various features. For more information, see "What Are SDM Templates?" on page 241 The switch can obtain the time from a Simple Network Time Protocol (SNTP) server, or you can set the time manually. Table 11-2 describes the settings that help the switch keep track of time. Table 11-2. Time Settings Feature Description SNTP Controls whether the switch obtains its system time from an SNTP server and whether communication with the SNTP server requires authentication and encryption. You can configure information for up to eight SNTP servers. The SNTP client on the switch can accept updates from both IPv4 and IPv6 SNTP servers. Real time clock (RTC) If SNTP is disabled, you can manually enter the system time and date. Time Zone Allows you to specify the offset from Coordinated Universal Time (UTC), which is also known as Greenwich Mean Time (GMT). Summer Time In some regions, the time shifts by one hour in the fall and spring. In the United States, this is called daylight saving time. The PowerConnect 7024P and 7048P switch ports are IEEE 802.3at-2009compliant (PoE Plus) and can provided up to 30W of power per port. For more information about PoE Plus support, see "What Are the Key PoE Plus Features for the PC7024P and PC7048P?" on page 243 Why Does System Information Need to Be Configured? Configuring system information is optional. However, it can be helpful in providing administrative information about the switch. For example, if you manage several standalone PowerConnect 7000 Series switches and have 240 Managing General System Settings Telnet sessions open with several different switches, the system name can help you quickly identify the switch because the host name replaces console as the CLI command prompt. The Banner can provide information about the switch status. For example, if multiple users connect to the switch, the message of the day (MOTD) banner might alert everyone who connects to the switch about a scheduled switch image upgrade. What Are SDM Templates? An SDM template is a description of the maximum resources a switch or router can use for various features. Different SDM templates allow different combinations of scaling factors, enabling different allocations of resources depending on how the device is used. In other words, SDM templates enable you to reallocate system resources to support a different mix of features based on your network requirements. PowerConnect 7000 Series switches support the following three templates: • Dual IPv4 and IPv6 (default) • IPv4 Routing • IPv4 Data Center Table 11-3 describes the parameters that are scaled for each template and the per-template maximum value of the parameter. Table 11-3. SDM Template Parameters and Values Parameter Dual IPv4/IPv6 IPv4 Only IPv4 Data Center ARP entries 6144 6144 6144 IPv4 unicast routes 8160 12256 8160 IPv6 Neighbor Discovery Protocol (NDP) entries 2560 0 0 IPv6 unicast routes 4096 0 0 ECMP next hops 4 4 16 IPv4 multicast routes 1536 2048 2048 IPv6 multicast routes 512 0 0 Managing General System Settings 241 SDM Template Configuration Guidelines When you configure the switch to use an SDM template that is not currently in use, you must reload the switch for the configuration to take effect. NOTE: If you attach a unit to a stack and its template does not match the stack's template, then the new unit will automatically reboot using the template used by the management unit. To avoid the automatic reboot, you may first set the template to the template used by the management unit. Then power off the new unit, attach it to the stack, and power it on. If the IPv4 Routing or IPv4 Data Center template is currently in use and you attempt to configure IPv6 routing features without first selecting the Dual IPv4-IPv6 Routing template, the IPv6 commands do not take effect. IPv6 features are not available when an IPv4-only template is active. Why is the System Time Needed? The switch uses the system clock to provide time stamps on log messages. Additionally, some show commands include the time in the command output. For example, the show users login-history command includes a Login Time field. The system clock provides the information for the Login Time field. How Does SNTP Work? SNTP assures accurate switch clock time synchronization. Time synchronization is performed by a network SNTP server. Time sources are established by Stratums. Stratums define the accuracy of the reference clock. The higher the stratum (where zero is the highest), the more accurate the clock. The switch is at a stratum that is one lower than its time source. For example, if the SNTP server in an internal network is a Stratum 3 device, the switch is a Stratum 4 device. You can configure the switch to request the time from an SNTP server on the network, or you can allow the switch to receive SNTP broadcasts. Requesting the time from a unicast SNTP server is more secure. Use this method if you know the IP address of the SNTP server on your network. If you allow the switch to receive SNTP broadcasts, any clock synchronization information is accepted, even if it has not been requested by the device. This method is less secure than polling a specified SNTP server. 242 Managing General System Settings To increase security, you can require authentication between the configured SNTP server and the SNTP client on the switch. Authentication is provided by Message Digest 5 (MD5). MD5 verifies the integrity of the communication and authenticates the origin of the communication. What Configuration Is Required for Plug-In Modules? The switch supports several different plug-in modules (also known as cards) for the expansion slots located on the back of the switch. For information about the slots and the supported modules, see "Expansion Slots for Plug-in Modules" on page 92. You can preconfigure the card type prior to inserting it into the switch. Hot-swap is supported on the PC7000 switch. However, the switch must be rebooted. Hot-swap support is not available for plug-in modules, which means the switch requires a reboot when you insert or remove cards. Additionally, the switch must be powered off to change the role of the ports on a module from stacking to Ethernet or vice-versa. Modules operate in the mode for which they are configured as a default. This means that the module configuration (Ethernet or stacking) does not appear in the running-config. Before inserting a new module into the expansion slot that was previously occupied by a different type of module, issue a no slot or clear config command from the CLI so that the switch can recognize the new module. What Are the Key PoE Plus Features for the PC7024P and PC7048P? Table 11-4 describes some of the key PoE Plus features the switches support. Table 11-4. PoE Plus Key Features (7024P and 7048P Only) Feature Description Global Usage Threshold Provides the ability to specify a power limit as a percentage of the maximum power available to PoE ports. Setting a limit prevents the PoE switch from reaching an overload condition. Managing General System Settings 243 Table 11-4. PoE Plus Key Features (7024P and 7048P Only) Feature Description Per-Port Power Prioritization Provides the ability to assign a priority to each PoE port. When the power budget of the PoE switch has been exhausted, the higher-priority ports are given preference over the lower-priority ports. Lower priority ports are automatically stopped from supplying power in order to provide power to higher-priority ports. Per-Port Power Limit Configurable power limit for each PoE-Plus port. Power Management Modes Supports two power-management modes: • Static—Allows you to reserve a guaranteed amount of power for a PoE port. This is useful for powering up devices which draw variable amount of power and provide them an assured power range to operate within. • Dynamic—Power is not reserved for a given port at any point of time. The power available with the PoE switch is calculated by subtracting the instantaneous power drawn by all the ports from the maximum available power. Thus more ports can be powered at the same time. This feature is useful to efficiently power up more number of devices when the available power with the PoE switch is limited Power Detection Mode Allows you to set the mode to legacy or 4-point 802.3AF detection. Enabling an additional high-power setting will allow the detection of 802.1at devices. Powered Device (PD) Disconnection Detection Mode Configurable setting to set the method that determines when a PD has disconnected from a port: • AC Disconnect—Assumes that when a valid PD is connected to a port, the AC impedance measured on its terminals is significantly lower than in the case of an open port (disconnected PD) • DC Disconnect—Measures current consumption to determine when a PD stops consuming current. 244 Managing General System Settings Default General System Information By default, no system information or time information is configured, and the SNTP client is disabled. The default SDM Template applied to the switch is the Dual IPv4-IPv6 template. The following table shows the default PoE Plus settings for the PowerConnect 7024P and 7048P switches. Table 11-5. PoE Plus Key Features (7024P and 7048P Only) Feature Description Global Usage Threshold 96% Per-Port Admin Status Auto Per-Port Power Prioritization Enabled (globally, per-port priority is Low Per-Port Power Limit None Power Management Mode Dynamic Power Detection Mode 802.3af Only Powered Device (PD) Disconnection Detection Mode AC Power Pairs alternative-a Managing General System Settings 245 Configuring General System Settings (Web) This section provides information about the OpenManage Switch Administrator pages for configuring and monitoring general system settings on the PowerConnect 7000 Series switch. For details about the fields on a page, click at the top of the page. System Information Use the System Information page to configure the system name, contact name, location, and asset tag. NOTE: From the System Information page, you can also initiate a Telnet session to the switch. To display the System Information page, click System → General → System Information in the navigation panel. Figure 11-1. System Information 246 Managing General System Settings Initiating a Telnet Session from the Web Interface NOTE: The Telnet client feature does not work with Microsoft Windows Internet Explorer 7 and later versions. Initiating this feature from any browser running on a Linux operating system is not supported. To launch a Telnet session: 1 From the System → General → System Information page, click the Telnet link. 2 Click the Telnet button. Figure 11-2. Telnet 3 Select the Telnet client, and click OK. Managing General System Settings 247 Figure 11-3. Select Telnet Client The selected Telnet client launches and connects to the switch CLI. Figure 11-4. Telnet Session 248 Managing General System Settings CLI Banner Use the CLI Banner page to configure a message for the switch to display when a user connects to the switch by using the CLI. You can configure different banners for various CLI modes and access methods. To display the CLI Banner page, click System → General → CLI Banner in the navigation panel. Figure 11-5. CLI Banner Managing General System Settings 249 SDM Template Preference Use the SDM Template Preference page to view information about template resource settings and to select the template that the switch uses. If you select a new SDM template for the switch to use, you must reboot the switch before the template is applied. To display the SDM Template Preference page, click System → General → SDM Template Preference in the navigation panel. Figure 11-6. SDM Template Preference 250 Managing General System Settings Clock If you do not obtain the system time from an SNTP server, you can manually set the date and time on the switch on the Clock page. The Clock page also displays information about the time settings configured on the switch. To display the Clock page, click System → Time Synchronization → Clock in the navigation panel. Figure 11-7. Clock NOTE: The system time cannot be set manually if the SNTP client is enabled. Use the SNTP Global Settings page to enable or disable the SNTP client. Managing General System Settings 251 SNTP Global Settings Use the SNTP Global Settings page to enable or disable the SNTP client, configure whether and how often the client sends SNTP requests, and determine whether the switch can receive SNTP broadcasts. To display the SNTP Global Settings page, click System → Time Synchronization → SNTP Global Settings in the navigation panel. Figure 11-8. SNTP Global Settings 252 Managing General System Settings SNTP Authentication Use the SNTP Authentication page to enable or disable SNTP authentication, to modify the authentication key for a selected encryption key ID, to designate the selected authentication key as a trusted key, and to remove the selected encryption key ID. NOTE: The SNTP server must be configured with the same authentication information to allow time synchronization to take place between the two devices. Click System → Time Synchronization → SNTP Authentication in the navigation panel to display the SNTP Authentication page. Figure 11-9. SNTP Authentication Adding an SNTP Authentication Key To configure SNTP authentication: 1 Open the SNTP Authentication page. 2 Click the Add link. Managing General System Settings 253 The Add Authentication Key page displays: Figure 11-10. Add Authentication Key 3 Enter a numerical encryption key ID and an authentication key in the appropriate fields. 4 If the key is to be used to authenticate a unicast SNTP server, select the Trusted Key check box. If the check box is clear, the key is untrusted and cannot be used for authentication. 5 Click Apply. The SNTP authentication key is added, and the device is updated. To view all configured authentication keys, click the Show All link. The Authentication Key Table displays. You can also use the Authentication Key Table to remove or edit existing keys. 254 Managing General System Settings Figure 11-11. Authentication Key Table SNTP Server Use the SNTP Server page to view and modify information about SNTP servers, and to add new SNTP servers that the switch can use for time synchronization. The switch can accept time information from both IPv4 and IPv6 SNTP servers. To display the SNTP Server page, click System → Time Synchronization → SNTP Server in the navigation panel. If no servers have been configured, the fields in the following image are not displayed. Managing General System Settings 255 Figure 11-12. SNTP Servers Defining a New SNTP Server To add an SNTP server: 1 Open the SNTP Servers page. 2 Click Add. The Add SNTP Server page displays. 256 Managing General System Settings Figure 11-13. Add SNTP Server 3 In the SNTP Server field, enter the IP address or host name for the new SNTP server. 4 Specify whether the information entered in the SNTP Server field is an IPv4 address, IPv6 address, or a hostname (DNS). 5 If you require authentication between the SNTP client on the switch and the SNTP server, select the Encryption Key ID check box, and then select the key ID to use. To define a new encryption key, see "Adding an SNTP Authentication Key" on page 253. NOTE: The SNTP server must be configured with the same authentication information to allow time synchronization to take place between the two devices. Managing General System Settings 257 To view all configured SNTP servers, click the Show All link. The SNTP Server Table displays. You can also use the SNTP Server Table page to remove or edit existing SNTP servers. Figure 11-14. 258 SNTP Servers Table Managing General System Settings Summer Time Configuration Use the Summer Time Configuration page to configure summer time (daylight saving time) settings. To display the Summer Time Configuration page, click System → Time Synchronization → Summer Time Configuration in the navigation panel. Figure 11-15. Summer Time Configuration NOTE: The fields on the Summer Time Configuration page change when you select or clear the Recurring check box. To use the preconfigured summer time settings for the United States or European Union, select the Recurring check box and specify USA or EU from the Location menu. Managing General System Settings 259 Time Zone Configuration Use the Time Zone Configuration to configure time zone information, including the amount time the local time is offset from UTC and the acronym that represents the local time zone. To display the Time Zone Configuration page, click System → Time Synchronization → Time Zone Configuration in the navigation panel. Figure 11-16. 260 Time Zone Configuration Managing General System Settings Card Configuration Use the Card Configuration page to control the administrative status of the rear-panel expansion slots (Slot 1 or Slot 2) and to configure the plug-in module to use in the slot. To display the Card Configuration page, click Switching → Slots → Card Configuration in the navigation panel. Figure 11-17. Card Configuration Managing General System Settings 261 Slot Summary Use the Slot Summary page to view information about the expansion slot status. To display the Slot Summary page, click Switching → Slots → Summary in the navigation panel. Figure 11-18. 262 Slot Summary Managing General System Settings Supported Cards Use the Supported Cards page to view information about the supported plug-in modules for the switch. To display the Supported Cards page, click Switching → Slots → Supported Cards in the navigation panel. Figure 11-19. Supported Cards Managing General System Settings 263 Power Over Ethernet Global Configuration (7024P/7048P Only) Use the PoE Global Configuration page to configure the PoE settings for the switch. To display the PoE Global Configuration page, click System → General → Power over Ethernet → Global Configuration in the navigation panel. Figure 11-20. 264 PoE Global Configuration Managing General System Settings Power Over Ethernet Interface Configuration (7024P/7048P Only) Use the PoE Interface Configuration page to configure the per-port PoE settings. From this page, you can also access the PoE Counters table and PoE Port Table. The PoE Port table allows you to view and configure PoE settings for multiple ports on the same page. To display the PoE Interface Configuration page, click System → General → Power over Ethernet → Interface Configuration in the navigation panel. Figure 11-21. PoE Interface Configuration Managing General System Settings 265 To view PoE statistics for each port, click Counters. Figure 11-22. PoE Counters Table To view the PoE Port Table, click Show All. Figure 11-23. PoE Port Table If you change any settings for one or more ports on the PoE Port Table page, click Apply to update the switch with the new settings. 266 Managing General System Settings Configuring System Settings (CLI) This section provides information about the commands you use to configure system information and time settings on the PowerConnect 7000 Series switch. For more information about these commands, see the PowerConnect 7000 Series CLI Reference Guide at support.dell.com/manuals. Configuring System Information Beginning in Privileged EXEC mode, use the following commands to configure system information. Command Purpose configure Enter Global Configuration mode. hostname name Configure the system name. The CLI prompt changes to the host name after you execute the command. name snmp-server contact Configure the name of the switch administrator. If the name contains a space, use quotation marks around the name. snmp-server location Configure the switch location. tag asset-tag [unit unit_id] Configure the asset tag for the switch. Use the unit keyword to configure the asset tag for each unit in a stack of switches. CTRL + Z Exit to Privileged EXEC mode. show system [id] Display system information. Include the id keyword to display additional system information. location Managing General System Settings 267 Configuring the Banner Beginning in Privileged EXEC mode, use the following commands to configure the MOTD, login, or User EXEC banner. The switch supports the following banner messages: • MOTD—Displays when a user connects to the switch. • Login—Displays after the MOTD banner and before the login prompt. • Exec—Displays immediately after the user logs on to the switch. Command Purpose configure Enter Global Configuration mode. banner Configure the banner message that displays when you {motd|login|exec} text connect to the switch (motd and login) or enter User EXEC mode (exec). Use quotation marks around a message if it includes spaces. line {telnet|ssh|console} Enter the terminal line configuration mode for Telnet, SSH, or the console. motd-banner Specify that the configured MOTD banner displays. To prevent the banner from displaying, enter no motdbanner. exec-banner Specify that the configured exec banner displays. To prevent the banner from displaying, enter no exec-banner. login-banner Specify that the configured login banner displays. To prevent the banner from displaying, enter no login-banner. CTRL + Z Exit to Privileged EXEC mode. show banner Display the banner status on all line terminals. 268 Managing General System Settings Managing the SDM Template Beginning in Privileged EXEC mode, use the following commands to set the SDM template preference and to view information about the available SDM templates. Command Purpose configure Enter Global Configuration mode. sdm prefer {dual-ipv4and-ipv6 default| ipv4routing {data-center | default}} Select the SDM template to apply to the switch after the next boot. CTRL + Z Exit to Privileged EXEC mode. show sdm prefer [template] View information about the SDM template the switch is currently using. Use the template variable to view the parameters for the specified template. Configuring SNTP Authentication and an SNTP Server Beginning in Privileged EXEC mode, use the following commands to require the SNTP client to use authentication when communicating with the SNTP server. The commands also show how to configure an SNTP server. Requiring authentication is optional. However, if you configure authentication on the switch SNTP client, the SNTP server must be configured with the same authentication information to allow time synchronization to take place between the two devices. Command Purpose configure Enter Global Configuration mode. sntp authentication-key Define an authentication key for SNTP. The variables are: key_id md5 key_word • key_id— The encryption key ID, which is a number from 1–4294967295. • key_word—The authentication key, which is a string of up to eight characters. Managing General System Settings 269 Command Purpose sntp trusted-key key_id Specify the authentication key the SNTP server must include in SNTP packets that it sends to the switch. The key_id number must be an encryption key ID defined in the previous step. sntp authenticate Require authentication for communication with the SNTP server. A trusted key must be configured before this command is executed. sntp server {ip_address | Define the SNTP server. hostname} [priority • ip_address—The IP address (or host name) of the SNTP priority] [key key_id] server to poll. The IP address can be an IPv4 or IPv6 address. • priority—(Optional) If multiple SNTP servers are defined, this number determines which server the switch polls first. The priority is 1–8, where 1 is the highest priority. If you do not specify a priority, the servers are polled in the order that they are entered. • key_id—(Optional) Enter an authentication key to use. The key must be previously defined by the sntp authentication-key command. sntp {unicast|broadcast} client enable This command enables the SNTP client and allows the switch to poll configured unicast SNTP servers for updates or receive broadcasts from any SNTP server. sntp client poll timer Specify how often the SNTP client requests SNTP packets from the configured server(s). seconds seconds—The poll interval can be 64, 128, 256, 512, or 1024 seconds. CTRL + Z Exit to Privileged EXEC mode. show sntp configuration Verify the SNTP configuration. show sntp status 270 View information about the SNTP updates. Managing General System Settings Setting the System Time and Date Manually Beginning in Privileged EXEC mode, use the following commands to configure the time and date, time zone, and summer time settings. Command Purpose clock set {mm/dd/yyyy Configure the time and date. You can enter the time first and then the date, or the date and then the time. hh:mm:ss} | {hh:mm:ss • hh:mm:ss —Time in hours (24-hour format, from 01-24), mm/dd/yyyy minutes (00-59), and seconds (00-59). • mm/dd/yyyy — Two digit month (1-12), two-digit date of the month (01-31), and four-digit year. clock timezone hours- Configure the time zone settings. offset hours-offset • hours-offset — Hours difference from UTC. (Range: –12 to [minutes minutes+13) offset] [zone acronym] • minutes-offset — Minutes difference from UTC. (Range: 0–59) • acronym — The acronym for the time zone. (Range: Up to four characters) clock summer-time recurring {usa | eu | {week day month hh:mm week day month hh:mm}} [offset offset] [zone acronym] Use this command if the summer time starts and ends every year based on a set pattern. For switches located in the United States or European Union, use the usa or eu keywords to use the preconfigured values. Otherwise, configure the start and end times by using the following values: • week — Week of the month. (Range: 1–5, first, last) • day — Day of the week. (The first three letters by name) • month — Month. (The first three letters by name; jan, for example.) • hh:mm — Time in 24-hour format in hours and minutes. (Range: hh: 0–23, mm: 0–59) • offset — Number of minutes to add during the summertime. (Range:1–1440) • acronym — The acronym for the time zone to be displayed when summertime is in effect. (Up to four characters) Managing General System Settings 271 Command Purpose clock summer-time date {date month | month date} year hh:mm {date month | month date} year hh:mm [offset offset] [zone acronym] Use this command if the summer time does not start and end every year according to a recurring pattern. You can enter the month and then the date, or the date and then the month. • date— Day of the month. (Range: 1-31.) • month — Month. (Range: The first three letters by name) • hh:mm — Time in 24-hour format in hours and minutes. (Range: hh: 0–23, mm: 0–59) • offset — Number of minutes to add during the summertime. (Range:1–1440) • acronym — The acronym for the time zone to be displayed when summertime is in effect. (Range: Up to four characters) CTRL + Z Exit to Privileged EXEC mode. show clock [detail] View information about the time. Include the detail keyword to view information about the time zone and summer time. Configuring the Expansion Slots Beginning in Privileged EXEC mode, use the following commands to configure and view information about the expansion slots and plug-in modules (cards). Command Purpose configure Enter Global Configuration mode. slot unit/slot cardindex Configured the specified slot (1–2) to use the plug-in module identified by the cardindex number (CID). To view the CID associated with each plug-in module, use the show supported cardtype command. CTRL + Z Exit to Privileged EXEC mode. show slot Display status information about the expansion slots. show supported cardtype Display information about the plug-in modules the switch supports. 272 Managing General System Settings Configuring PoE Settings (7024P/7048P Only) Beginning in Privileged EXEC mode, use the following commands to configure PoE information. Command Purpose configure Enter Global Configuration mode. power inline usagethreshold threshold Specify the maximum usage for PoE power on the system. The threshold variable (range: 12–99%) is a percentage of total system power. power inline priority enable Enable the port priority feature on the switch. power inline management {static | dynamic} Set the power-management mode for the switch. power inline detection Set the power-management mode for the switch. {dot3af | dot3af+legacy • 802.3af-only—IEEE 802.3af detection scheme is used. | legacy-only} • 802.3af+legacy—IEEE 802.3af 4point detection scheme is used and when it fails to detect a connected PD, legacy capacitive detection is used. • legacy-only—only legacy capacitive detection scheme is used. interface interface Enter interface configuration mode for the specified port. The interface variable includes the interface type and number, for example gigabitethernet 1/0/3. power inline {auto | never} Set the PoE device discovery admin mode. • auto — Enables the device discovery protocol and, if found, supplies power to the device. • never — Disables the device discovery protocol and stops supplying power to the device. power inline priority {critical | high | medium | low} Configures the port priority level for the delivery of power to an attached device. Managing General System Settings 273 Command Purpose power inline high-power Configure the port high power mode for connected-device {legacy | dot3at} compatibility. • legacy—Use this mode if the device can power up (more than 12.95 Watts) with higher current and cannot identify itself as Class 4 device. • dot3at—Use this mode if the device is a Class 4 device capable of figuring out power requirement through LLDP. power inline limit {class Set the per-port power limit. | none | user-defined • class—Allows the port to draw up to the advertised class limit} maximum power. • none—Allows port to draw up to class 0 maximum power in low power mode and class 4 maximum power in high power mode. • user-defined limit—Allows the port to draw up to user defined configured value. The range of limit is 100031200 milliwatts. power inline detection Set the power-management mode for the port. This {dot3af | dot3af+legacy setting overrides the mode set for the switch in global | legacy-only} configuration mode. • 802.3af-only—IEEE 802.3af detection scheme is used. • 802.3af+legacy—IEEE 802.3af 4point detection scheme is used and when it fails to detect a connected PD, legacy capacitive detection is used. • legacy-only—only legacy capacitive detection scheme is used. power inline disconnect Configure the PD disconnect type for the port. {ac | dc | none} power inline port-pair {alternative-a | alternative-b} Specify the technique for carrying power over the cabling: • alternative-a—Power is carried over the same wire pairs as the data. • alternative-b—Power is carried over unused wire pairs in the cable. power inline powereddevice type 274 Provide a description to represent the type of device connected to the port. Managing General System Settings Command Purpose power inline reset (Optional) Reset the port. You might use this command if the port is stuck in an Error state. CTRL + Z Exit to Privileged EXEC mode. show power inline Display PoE information for the switch. show power inline Display PoE information for the specified interface. interface Managing General System Settings 275 General System Settings Configuration Examples This section contains the following examples: • Configuring System and Banner Information • Configuring SNTP • Configuring the Time Manually Configuring System and Banner Information In this example, an administrator configures the following system information: • System name: PC7048 • System contact: Jane Doe • System location: RTP100 • Asset tag: 006429 The administrator then configures the MOTD banner to alert other switch administrators of the connected topology. To configure the switch: 1 Configure the hosts name. console#configure console(config)#hostname PC7048 2 Configure the contact, location, and asset tag. Notice that the prompt changed to the host name. PC7048(config)#snmp-server contact “Jane Doe” PC7048(config)#snmp-server location RTP100 PC7048(config)#asset-tag 006429 3 Configure the message that displays when a user connects to the switch. PC7048(config)#banner motd “This switch connects users in cubicles C121-C139.” PC7048(config)#exit 4 View system information to verify the configuration. PC7048#show system System Description: Dell Ethernet Switch System Up Time: 0 days, 19h:36m:36s 276 Managing General System Settings System Contact: Jane Doe System Name: PC7048 System Location: RTP100 Burned In MAC Address: 001E.C9AA.AA07 System Object ID: 1.3.6.1.4.1.674.10895.3035 System Model ID: PCT7048 Machine Type: PowerConnect 7048 Temperature Sensors: Unit Temperature (Celsius) Status ----------------------------1 43 OK Power Supplies: Unit Description Status Source ----------------------------1 Main OK AC 1 Secondary Error DC 5 View additional information about the system. PC7048#show system id Service Tag: Chassis Service Tag: N/A Serial Number: 7024NX1011 Asset Tag: unit-1 Unit Service tag Chassis Serv tag ---- ----------- ---------------1 N/A Serial number ------------70498NX1011 Asset tag --------unit-1 6 Initiate a new Telnet session to verify the MOTD. Managing General System Settings 277 Figure 11-24. 278 Verify MOTD Managing General System Settings Configuring SNTP The commands in this example configure the switch to poll an SNTP server to synchronize the time. Additionally, the SNTP sessions between the client and server must be authenticated. To configure the switch: 1 Configure the authentication information. The SNTP server must be configured with the same authentication key and ID. console#configure console(config)#sntp authentication-key 23456465 md5 sntpkey console(config)#sntp trusted-key 23456465 console(config)#sntp authenticate 2 Specify the IP address of the SNTP server to poll and include the authentication key. This command automatically enables polling and sets the priority to 1. console(config)#sntp server 192.168.10.30 key 23456465 console(config)#sntp unicast client enable 3 Verify the configuration. console#show sntp configuration Polling interval: 512 seconds MD5 Authentication keys: 23456465 Authentication is required for synchronization. Trusted keys: 23456465 Unicast clients: Enable Unicast servers: Server Key Polling Priority ---------------------- --------- -------192.168.10.30 23456465 Enabled 1 Managing General System Settings 279 4 View the SNTP status on the switch. console#show sntp status Client Mode: Last Update Time: Unicast MAR 01 09:12:43 2010 Unicast servers: Server Status Last response --------------- ------------ --------------------192.168.10.30 Other 09:12:43 Mar 1 2011 280 Managing General System Settings Configuring the Time Manually The commands in this example manually set the system time and date. The time zone is set to Eastern Standard Time (EST), which has an offset of -5 hours. Summer time is enabled and uses the preconfigured United States settings. To configure the switch: 1 Configure the time zone offset and acronym. console#configure console(config)#clock timezone -5 zone EST 2 Configure the summer time (daylight saving time) to use the preconfigured settings for the United States. console(config)#clock summer-time recurring us 3 Set the local time and date. console(config)#clock set 16:13.06 03/01/2010 4 Verify the time settings. console#show clock detail 00:27:19 EST(UTC-5:00) Feb 3 2039 No time source Time zone: Acronym is EST Offset is UTC-5:00 Summertime: Acronym not configured Recurring every year (USA) Begins on second Sunday of Mar at 02:00 Ends on first Sunday of Nov at 02:00 Offset is +60 minutes Managing General System Settings 281 282 Managing General System Settings Configuring SNMP 12 The topics covered in this chapter include: • SNMP Overview • Default SNMP Values • Configuring SNMP (Web) • Configuring SNMP (CLI) • SNMP Configuration Examples SNMP Overview Simple Network Management Protocol (SNMP) provides a method for managing network devices. The PowerConnect 7000 Series switches support SNMP version 1, SNMP version 2, and SNMP version 3. What Is SNMP? SNMP is a standard protocol that enables remote monitoring and management of a device through communication between an SNMP manager and an SNMP agent on the remote device. The SNMP manager is typically part of a Network Management System (NMS) that runs on an administrative host. The switch software includes Management Information Base (MIB) objects that the SNMP agent queries and modifies. The switch uses standard public MIBs and private MIBs. A MIB acts as a structured road map for managed objects. A managed object is any feature or setting that can be configured or monitored on the switch. An Object Identifier (OID) is the unique number assigned to an object defined in a MIB. An OID is written as a sequence of subidentifiers in decimal notation. Configuring SNMP 283 The SNMP agent maintains a list of variables that are used to manage the switch. The variables are defined in the MIB. The MIB presents the variables controlled by the agent. The SNMP agent defines the MIB specification format, as well as the format used to access the information over the network. Access rights to the SNMP agent are controlled by access strings. SNMP v3 also applies access control and a new traps mechanism to SNMPv1 and SNMPv2 PDUs. In addition, the User Security Model (USM) is defined for SNMPv3 and includes: • Authentication — Provides data integrity and data origin authentication. • Privacy — Protects against disclosure of message content. Cipher-BockChaining (CBC) is used for encryption. Either authentication is enabled on an SNMP message, or both authentication and privacy are enabled on an SNMP message. However privacy cannot be enabled without authentication. • Timeliness — Protects against message delay or message redundancy. The SNMP agent compares incoming message to the message time information. • Key Management — Defines key generation, key updates, and key use. Authentication or Privacy Keys are modified in the SNMPv3 User Security Model (USM). What Are SNMP Traps? SNMP is frequently used to monitor systems for fault conditions such as temperature violations, link failures, and so on. Management applications can monitor for these conditions by polling the appropriate OIDs with the get command and analyzing the returned data. This method has its drawbacks. If it is done frequently, significant amounts of network bandwidth can be consumed. If it is done infrequently, the response to the fault condition may not occur in a timely fashion. SNMP traps avoid these limitations of the polling method. An SNMP trap is an asynchronous event indicating that something significant has occurred. This is analogous to a pager receiving an important message, except that he SNMP trap frequently contains all the information needed to diagnose a fault. 284 Configuring SNMP You can configure various features on the switch to generate SNMP traps that inform the NMS about events or problems that occur on the switch. Traps generated by the switch can also be viewed locally by using the web-based interface or CLI. Why Is SNMP Needed? Some network administrators prefer to use SNMP as the switch management interface. Settings that you view and configure by using the web-based Dell OpenManage Switch Administrator and the CLI are also available by using SNMP. If you do not use NMS software to manage or monitor other devices on your network, it might not be necessary to configure SNMP on the switch. Default SNMP Values By default, SNMPv2 is automatically enabled on the device. SNMPv1 and SNMPv3 are disabled. To enable SNMPv3, you must define a local engine ID for the device. The local engineID is by default set to the switch MAC address, however when the switch operates in a stacking mode, it is important to manually configure the local engineID for the stack. This local engineID must be defined so that it is unique within the network. It is important to do this because the default engineID in a stack is the MAC address of the master unit, which may change if the master unit fails and another unit takes over the stack. Table 12-1 summarizes the default values for SNMP. Table 12-1. SNMP Defaults Parameter Default Value SNMPv1 Disabled SNMPv2 Enabled SNMPv3 Disabled SNMP traps Enabled SNMP trap receiver None configured Switch traps Enabled Configuring SNMP 285 Table 12-1. SNMP Defaults Parameter Default Value QoS traps Enabled Multicast traps Disabled Captive Portal traps Disabled OSPF traps Disabled Table 12-2 describes the two views that are defined by default. Table 12-2. SNMP Default Views View Name OID Subtree View Type Default iso Included snmpVacmMIB Excluded usmUser Excluded snmpCommunityTable Excluded iso Included DefaultSuper By default, three groups are defined. Table 12-3 describes the groups. The Read, Write, and Notify values define the preconfigured views that are associated with the groups. Table 12-3. SNMP Default Groups Group Name Security Level Read Write Notify DefaultRead No Auth No Priv Default – Default DefaultWrite No Auth No Priv Default Default Default DefaultSuper No Auth No Priv DefaultSuper DefaultSuper DefaultSuper 286 Configuring SNMP Configuring SNMP (Web) This section provides information about the OpenManage Switch Administrator pages for configuring and monitoring the SNMP agent on a PowerConnect 7000 Series switch. For details about the fields on a page, click at the top of the page. NOTE: For some features, the control to enable or disable traps is available from a configuration page for that feature and not from the Trap Manager pages that this chapter describes. SNMP Global Parameters Use the Global Parameters page to enable SNMP and Authentication notifications. To display the Global Parameters page, click System → SNMP → Global Parameters in the navigation panel. Figure 12-1. SNMP Global Parameters Configuring SNMP 287 SNMP View Settings Use the SNMP View Settings page to create views that define which features of the device are accessible and which are blocked. You can create a view that includes or excludes OIDs corresponding to interfaces. To display the View Settings page, click System → SNMP → View Settings in the navigation panel. Figure 12-2. SNMP View Settings Adding an SNMP View To add a view: 1 Open the View Settings page. 2 Click Add. The Add View page displays: 288 Configuring SNMP Figure 12-3. Add View 3 Specify a name for the view and a valid SNMP OID string. 4 Select the view type. 5 Click Apply. The SNMP view is added, and the device is updated. Click Show All to view information about configured SNMP Views. Configuring SNMP 289 Access Control Group Use the Access Control Group page to view information for creating SNMP groups, and to assign SNMP access privileges. Groups allow network managers to assign access rights to specific device features or features aspects. To display the Access Control Group page, click System → SNMP → Access Control in the navigation panel. Figure 12-4. SNMP Access Control Group Adding an SNMP Group To add a group: 1 Open the Access Control Configuration page. 2 Click Add. The Add an Access Control Configuration page displays: 290 Configuring SNMP Figure 12-5. Add Access Control Group 3 Specify a name for the group. 4 Select a security model and level 5 Define the context prefix and the operation. 6 Click Apply to update the switch. Click Show All to view information about existing access control configurations. Configuring SNMP 291 SNMPv3 User Security Model (USM) Use the User Security Model page to assign system users to SNMP groups and to define the user authentication method. NOTE: You can also use the Local User Database page under Management Security to configure SNMPv3 settings for users. For more information, see "Configuring Authentication, Authorization, and Accounting" on page 175. To display the User Security Model page, click System → SNMP → User Security Model in the navigation panel. Figure 12-6. SNMPv3 User Security Model Adding Local SNMPv3 Users to a USM To add local users: 1 Open the User Security Model page. 2 Click Add Local User. The Add Local User page displays: 292 Configuring SNMP Figure 12-7. Add Local Users 3 Define the relevant fields. 4 Click Apply to update the switch. Click Show All to view the User Security Model Table, which contains information about configured Local and Remote Users. Adding Remote SNMPv3 Users to a USM To add remote users: 1 Open the SNMPv3 User Security Model page. 2 Click Add Remote User. The Add Remote User page displays: Configuring SNMP 293 Figure 12-8. Add Remote Users 3 Define the relevant fields. 4 Click Apply to update the switch. Click Show All to view the User Security Model Table, which contains information about configured Local and Remote Users. 294 Configuring SNMP Communities Access rights for SNMPv1 and SNMPv2 are managed by defining communities Communities page. When the community names are changed, access rights are also changed. SNMP Communities are defined only for SNMP v1 and SNMP v2. To display the Communities page, click System → SNMP → Communities in the navigation panel. Figure 12-9. SNMP Communities Adding SNMP Communities To add a community: 1 Open the Communities page. 2 Click Add. The Add SNMPv1,2 Community page displays: Configuring SNMP 295 Figure 12-10. Add SNMPv1,2 Community 3 Specify the IP address of an SNMP management station and the community string to act as a password that will authenticate the management station to the SNMP agent on the switch. 4 Select the access mode. 5 Click Apply to update the switch. Click Show All to view the communities that have already been configured. 296 Configuring SNMP Notification Filter Use the Notification Filter page to set filtering traps based on OIDs. Each OID is linked to a device feature or a feature aspect. The Notification Filter page also allows you to filter notifications. To display the Notification Filter page, click System → SNMP → Notification Filters in the navigation panel. Figure 12-11. SNMP Notification Filter Adding a Notification Filter To add a filter: 1 Open the Notification Filter page. 2 Click Add. The Add Filter page displays: Configuring SNMP 297 Figure 12-12. Add Notification Filter 3 Specify the name of the filter, the OID for the filter. 4 Choose whether to send (include) traps or informs to the trap recipient or prevent the switch from sending (exclude) the traps or informs. 5 Click Apply to update the switch. Click Show All to view information about the filters that have already been configured. Notification Recipients Use the Notification Recipients page to view information for defining filters that determine whether traps are sent to specific users, and the trap type sent. SNMP notification filters provide the following services: • Identifying Management Trap Targets • Trap Filtering • Selecting Trap Generation Parameters • Providing Access Control Checks To display the Notification Recipients page, click System → SNMP → Notification Recipient in the navigation panel. 298 Configuring SNMP Figure 12-13. SNMP Notification Recipient Adding a Notification Recipient To add a recipient: 1 Open the Notification Recipient page. 2 Click Add. The Add Recipient page displays: Configuring SNMP 299 Figure 12-14. Add Notification Recipient 3 Specify the IP address or hostname of the host to receive notifications. 4 Select whether to send traps or informs to the specified recipient 5 Define the relevant fields for the SNMP version you use. 6 Configure information about the port on the recipient. 7 Click Apply to update the switch. Click Show All to view information about the recipients that have already been configured. 300 Configuring SNMP Trap Flags The Trap Flags page is used to specify which traps you want to enable or disable. When the condition identified by an active trap is encountered by the switch, a trap message is sent to any enabled SNMP Trap Receivers, and a message is written to the trap log. To access the Trap Flags page, click Statistics/RMON → Trap Manager → Trap Flags in the navigation panel. Figure 12-15. Trap Flags Configuring SNMP 301 OSPFv2 Trap Flags The OSPFv2 Trap Flags page is used to specify which OSPFv2 traps you want to enable or disable. When the condition identified by an active trap is encountered by the switch, a trap message is sent to any enabled SNMP Trap Receivers, and a message is written to the trap log. To access the OSPFv2 Trap Flags page, click Statistics/RMON → Trap Manager → OSPFv2 Trap Flags in the navigation panel. Figure 12-16. 302 OSPFv2 Trap Flags Configuring SNMP OSPFv3 Trap Flags The OSPFv3 Trap Flags page is used to specify which OSPFv3 traps you want to enable or disable. When the condition identified by an active trap is encountered by the switch, a trap message is sent to any enabled SNMP Trap Receivers, and a message is written to the trap log. To access the OSPFv3 Trap Flags page, click Statistics/RMON → Trap Manager → OSPFv3 Trap Flags in the navigation panel. Figure 12-17. OSPFv3 Trap Flags Configuring SNMP 303 Trap Log The Trap Log page is used to view entries that have been written to the trap log. To access the Trap Log page, click Statistics/RMON → Trap Manager → Trap Log in the navigation panel. Figure 12-18. Trap Logs Click Clear to delete all entries from the trap log. 304 Configuring SNMP Configuring SNMP (CLI) This section provides information about the commands you use to manage and view SNMP features on the switch. For more information about these commands, see the PowerConnect 7000 Series CLI Reference Guide at support.dell.com/manuals. Configuring the SNMPv3 Engine ID To use SNMPv3, the switch must have engine ID. You can specify your own ID or use the default string that is generated using the MAC address of the switch. If the SNMPv3 engine ID is deleted, or if the configuration file is erased, then SNMPv3 cannot be used. Since the EngineID should be unique within an administrative domain, the following guidelines are recommended: • For standalone switches use the default keyword to configure the Engine ID. • For a stack of switches, configure your own EngineID, and verify that is unique within your administrative domain. Changing the value of SNMP EngineID has important side-effects. A user's password (entered on the command line) is converted to an MD5 or SHA security digest. This digest is based on both the password and the local engine ID. The command line password is then destroyed, as required by RFC 2274. Because of this deletion, if the local value of engineID changes, the security digests of SNMPv3 users will be invalid, and the users will have to be reconfigured. Beginning in Privileged EXEC mode, use the following commands to configure an engine ID for SNMP. Command Purpose configure Enter Global Configuration mode Configuring SNMP 305 Command Purpose snmp-server engineID local {engineid-string | default} Configure the SNMPv3 Engine ID. • engineid-string — The character string that identifies the engine ID. The engine ID is a concatenated hexadecimal string. Each byte in hexadecimal character strings is two hexadecimal digits. Each byte can be separated by a period or colon. (Range: 6-32 characters) • default — The engineID is created automatically, based on the device MAC address. exit Exit to Privileged EXEC mode. show snmp engineid View the local SNMP engine ID. Configuring SNMP Views, Groups, and Users Beginning in Privileged EXEC mode, use the following commands to define SNMP views, and SNMP groups, and local and remote SNMPv3 users. Command Purpose configure Enter Global Configuration mode snmp-server view view- Configure the SNMP view. When you configure groups, name oid-tree {included users, and communities, you can specify a view to associate | excluded} with the group, user, or community • view-name — Specifies the name of the view. (Range: 130 characters.) • oid-tree — Specifies the object identifier of the ASN.1 subtree to be included or excluded from the view. To identify the subtree, specify a text string consisting of numbers, such as 1.3.6.2.4, or a word, such as system. Replace a single subidentifier with the asterisk (*) wildcard to specify a subtree family; for example 1.3.*.4. • included — Indicates that the view type is included. • excluded — Indicates that the view type is excluded. 306 Configuring SNMP Command Purpose snmp-server group groupname {v1 | v2 | v3 {noauth | auth | priv} [notify view-name]} [context view-name] [read view-name] [write view-name] Specify the identity string of the receiver and set the receiver timeout value. • groupname — Specifies the name of the group. (Range: 1-30 characters.) • v1 — Indicates the SNMP Version 1 security model. • v2 — Indicates the SNMP Version 2 security model. • v3 — Indicates the SNMP Version 3 security model. • noauth — Indicates no authentication of a packet. Applicable only to the SNMP Version 3 security model. • auth — Indicates authentication of a packet without encrypting it. Applicable only to the SNMP Version 3 security model. • priv — Indicates authentication of a packet with encryption. Applicable only to the SNMP Version 3 security model. • view-name — Specifies the view (defined in the previous step) to use for the context, notification, read, and write privileges for the group. Configuring SNMP 307 Command Purpose snmp-server user Configure a new SNMPv3 user. username groupname • username — Specifies the name of the user on the host [remote engineid-string] that connects to the agent. (Range: 1-30 characters.) [{auth-md5 password | • groupname — Specifies the name of the group to which auth-sha password | the user belongs. (Range: 1-30 characters.) auth-md5-key md5-key | auth-sha-key sha-key} • engineid-string — Specifies the engine ID of the remote [priv-des password | SNMP entity to which the user belongs. The engine ID is priv-des-key des-key]] a concatenated hexadecimal string. Each byte in the hexadecimal character string is two hexadecimal digits. The remote engine id designates the remote management station, and should be defined to enable the device to receive acknowledgements to "informs." (Range: 5-32 characters.) • auth-md5 — The HMAC-MD5-96 authentication level. • auth-sha — The HMAC-SHA-96 authentication level. • password — A password. (Range: 1 to 32 characters.) • auth-md5-key — The HMAC-MD5-96 authentication level. Enter a pregenerated MD5 key. • auth-sha-key — The HMAC-SHA-96 authentication level. Enter a pregenerated SHA key. • md5-key — Character string—length 32 hex characters. • sha-key — Character string—length 48 characters. • priv-des — The CBC-DES Symmetric Encryption privacy level. Enter a password. • priv-des-key — The CBC-DES Symmetric Encryption privacy level. The user should enter a pregenerated MD5 or SHA key depending on the authentication level selected. • des-key — The pregenerated DES encryption key. Length is determined by authentication method selected—32 hex characters if MD5 Authentication is selected, 48 hex characters if SHA Authentication is selected. exit Exit to Privileged EXEC mode. show snmp views View SNMP view configuration information. 308 Configuring SNMP Command Purpose show snmp group [group_name] View SNMP group configuration information. show snmp user [user_name] View SNMP user configuration information. Configuring Communities Beginning in Privileged EXEC mode, use the following commands to configure access rights for SNMPv1 and SNMPv2. Command Purpose configure Enter Global Configuration mode snmp-server community Configure the community string and specify access criteria string [ro | rw | su] for the community. [view view-name] • community-string — Acts as a password and is used to [ipaddress ip_address] authenticate the SNMP management station to the switch. The string must also be defined on the NMS in order for the NMS to access the SNMP agent on the switch (Range: 1-20 characters) • ro — Indicates read-only access • rw — Indicates read-write access. • view-name — Specifies the name of a previously defined MIB view. • ip_address — Specifies the IP address of the management station. If no IP address is specified, all management stations are permitted Configuring SNMP 309 Command Purpose snmp-server community- Map the internal security name for SNMP v1 and SNMP group community-string v2 security models to the group name. group-name [ipaddress • community-string — Community string that acts like a ip-address] password and permits access to the SNMP protocol. (Range: 1-20 characters) • group-name — Name of a previously defined group. The group defines the objects available to the community. (Range: 1-30 characters) • ip-address — Management station IP address. Default is all IP addresses. exit Exit to Privileged EXEC mode. show snmp View SNMP settings and verify the configuration 310 Configuring SNMP Configuring SNMP Notifications (Traps and Informs) Beginning in Privileged EXEC mode, use the following commands to allow the switch to send SNMP traps and to configure which traps are sent. Command Purpose configure Enter Global Configuration mode snmp-server enable traps [acl | all | auto-copy-sw | captive-portal cp-type | dot1q | dvrmp | link | maclock | multipleusers | ospf ospftype | ospfv3 ospfv3type | pim | poe | snmp authentication | spanning-tree | stack | vrrp] Specify the traps to enable. The captive portal, OSPF and OSPFv3 traps include several different traps that can be enabled. For more information, use the CLI command help or see the CLI Command Reference. snmp-server filter filter- Configure a filter for SNMP traps and informs based on name oid-tree {included OIDs. Each OID is linked to a device feature or a feature | excluded} aspect. • filter-name — Specifies the label for the filter record that is being updated or created. The name is used to reference the record. (Range: 1-30 characters.) • oid-tree — Specifies the object identifier of the ASN.1 subtree to be included or excluded from the view. To identify the subtree, specify a text string consisting of numbers, such as 1.3.6.2.4, or a word, such as system. Replace a single subidentifier with the asterisk (*) wildcard to specify a subtree family; for example, 1.3.*.4. • included — Indicates that the filter type is included. • excluded — Indicates that the filter type is excluded. Configuring SNMP 311 Command Purpose snmp-server host host- For SNMPv1 and SNMPv2, configure the system to receive addr [informs [timeout SNMP traps or informs. seconds] [retries retries] • host-addr — Specifies the IP address of the host (targeted | traps version {1 | 2}]] recipient) or the name of the host. (Range:1-158 community-string [udpcharacters). port port] [filter • informs — Indicates that SNMPv2 informs are sent to filtername] this host • timeout seconds — Number of seconds to wait for an acknowledgment before resending informs. The default is 15 seconds. (Range: 1-300 characters.) • retries — Maximum number of times to resend an inform request. The default is 3 attempts. • traps — Indicates that SNMP traps are sent to this host – version 1 — Indicates that SNMPv1 traps will be used – version 2 — Indicates that SNMPv2 traps will be used • community-string — Specifies a password-like community string sent with the notification operation. (Range: 1-20 characters) • port — UDP port of the host to use. The default is 162. (Range: 1-65535 characters.) • filtername — A string that is the name of the filter that defines the filter for this host. If unspecified, does not filter anything (Range: 1-30 characters.) 312 Configuring SNMP Command Purpose snmp-server v3-host {ip- For SNMPv3, configure the system to receive SNMP traps or informs. address | hostname} username {traps | • ip-address — Specifies the IP address of the host informs} [noauth | auth (targeted recipient). | priv] [timeout • hostname — Specifies the name of the host. (Range: 1seconds] [retries retries] 158 characters.) [udpport port] [filter filtername] • username — Specifies user name used to generate the notification. (Range: 1-25 characters.) • traps — Indicates that SNMP traps are sent to this host. • informs — Indicates that SNMPv2 informs are sent to this host. • noauth — Specifies sending of a packet without authentication. • auth — Specifies authentication of a packet without encrypting it • priv — Specifies authentication and encryption of a packet. • seconds — Number of seconds to wait for an acknowledgment before resending informs. This is not allowed for hosts configured to send traps. The default is 15 seconds. (Range: 1-300 seconds.) • retries — Maximum number of times to resend an inform request. This is not allowed for hosts configured to send traps. The default is 3 attempts. (Range: 0-255 retries.) • port — UDP port of the host to use. The default is 162. (Range: 1-65535.) • filter-name — Specifies the optional filter (defined with the snmp-server filter command) to use for the host. (Range: 1-30 characters.) exit Exit to Privileged EXEC mode. show trapflags View the status of the configurable SNMP traps. Configuring SNMP 313 SNMP Configuration Examples This section contains the following examples: • Configuring SNMPv1 and SNMPv2 • Configuring SNMPv3 Configuring SNMPv1 and SNMPv2 This example shows how to complete a basic SNMPv1/v2 configuration. The commands enable read-only access from any host to all objects on the switch using the community string public, and enable read-write access from any host to all objects on the switch using the community string private. This example also shows how to allow the switch to generate traps for all features that produce traps. The traps are sent to the host with an IP address of 192.168.3.65 using the community string public. To configure the switch: 1 Configure the public community string. console#configure console(config)#snmp-server community public ro 2 Configure the private community string. console(config)#snmp-server community private rw 3 Enable all traps and specify the IP address of the host where the traps should be sent. console(config)#snmp-server enable traps all console(config)#snmp-server host 192.168.3.65 public console(config)#exit 4 View the current SNMP configuration on the switch. console#show snmp Community-String -------------------private public 314 Configuring SNMP Community-Access ---------------Read/Write Read Only View Name IP Address --------- ------Default All Default All Community-String ----------------private public Group Name -------------DefaultWrite DefaultRead IP Address -----------All All Traps are enabled. Authentication trap is enabled. Version 1,2 notifications Target Addr. Type Community Version UDP Filter TO Port Name Sec ------------ ---- --------- -------- ----- --192.168.3.65 Trap public 1 162 Version 3 notifications Target Addr. Type Username Security UDP Filter TO Level Port Name Sec ------------ ---- --------- ------- ----- ----- --- Retries ------- Retries ------- System Contact: System Location: Configuring SNMPv3 This example shows how to complete a basic SNMPv3 configuration. The commands create a view that includes objects from the internet MIB subtree (OID 1.3.6.1), which includes all objects on the switch. The user named admin has read-write privileges to all objects within the view (in other words, all objects on the switch) after supplying the appropriate authentication credentials (secretkey). To configure the switch: 1 Configure the view. view_snmpv3 and specify the objects to include. console#configure console(config)#snmp-server view view_snmpv3 internet included 2 Create the group group_snmpv3 and allow read-write access to the view configured in the previous step. console(config)#snmp-server group group_snmpv3 v3 auth read view_snmpv3 write view_snmpv3 Configuring SNMP 315 3 Create the user admin, assign the user to the group, and specify the authentication credentials. console(config)#snmp-server user admin group_snmpv3 auth-md5 secretkey 4 Specify the IP address of the host where traps are to be sent. Packet authentication using MD5-SHA is enabled for the traps. console(config)#snmp-server v3-host 192.168.3.35 admin traps auth console(config)#exit 5 View the current SNMP configuration on the switch. The output includes the SNMPv1/2 configuration in the previous example. console#show snmp Community-String -------------------private public Community-Access ---------------Read/Write Read Only Community-String ----------------private public Group Name -------------DefaultWrite DefaultRead View Name IP Address --------- ------Default All Default All IP Address -----------All All Traps are enabled. Authentication trap is enabled. Version 1,2 notifications Target Addr. Type Community Version UDP Filter TO Port Name Sec ------------ ---- --------- -------- ----- --192.168.3.65 Trap public 1 162 Version 3 notifications Target Addr. Type Username Security Level ------------ ---- --------- ------192.168.3.35 Trap admin Auth-NoP System Contact: System Location: 316 Configuring SNMP UDP Filter TO Port Name Sec ----- ----- --162 15 Retries ------- Retries ------3 console#show snmp views Name -----------------Default Default Default Default view_snmpv3 DefaultSuper OID Tree -----------------------iso snmpVacmMIB usmUser snmpCommunityTable internet iso Type -----------Included Excluded Excluded Excluded Included Included console#show snmp group Name Context Model Prefix ------------ -------- -----DefaultRead "" V1 DefaultRead "" V2 DefaultSuper "" V1 DefaultSuper "" V2 DefaultWrite "" V1 DefaultWrite "" V2 group_snmpv3 "" V3 Security Level -------NoAuthNoPriv NoAuthNoPriv NoAuthNoPriv NoAuthNoPriv NoAuthNoPriv NoAuthNoPriv AuthNoPriv Read Views Write -------- -----Default "" Notify Default Default "" DefaultSuDefault per Super DefaultSuDefault per Super Default Default Default ------Default Default Super Default Super Default Default Default view_snmpview_sn "" v3 mpv3 console#show snmp user Name Group Name --------admin ----------group_snmpv3 Auth Meth ----MD5 Priv Meth ----- Remote Engine ID ---------------800002a203001ec9aaaa07 Configuring SNMP 317 318 Configuring SNMP Managing Images and Files 13 This chapter describes how to upload, download, and copy files, such as firmware images and configuration files, on the switch. The topics covered in this chapter include: • Image and File Management Overview • Managing Images and Files (Web) • Managing Images and Files (CLI) • File and Image Management Configuration Examples NOTE: For information about the Auto Configuration feature that enables the switch to automatically upgrade the image or load a new configuration file during the boot process, see Automatically Updating the Image and Configuration. Image and File Management Overview What Files Can Be Managed? PowerConnect 7000 Series switches maintain several different types of files on the flash file system. Table 13-1 describes the files that you can manage. The table also lists the type of action you can take on the file, which is one or more of the following: • Download the file to the switch from a remote system (or USB flash drive). • Upload the file from the switch to a remote system (or USB flash drive). • Copy the file from one location on the file system to another location. Managing Images and Files 319 Table 13-1. Files to Manage File Action Description image Download Upload Copy Firmware for the switch. The switch can maintain two images: the active image and the backup image. startup-config Download Upload Copy Contains the software configuration that loads during the boot process. running-config Download Upload Copy Contains the current switch configuration. backup-config Download Upload Copy An additional configuration file that serves as a backup. Configuration script Download Upload Text file with CLI commands. When you activate a script on the switch, the commands are executed and added to the running-config. Log files Upload Provides various information about events that occur on the switch. For more information, see Monitoring and Logging System Information. SSH key files Download Contains information to authenticate SSH sessions. The switch supports the following files for SSH: • SSH-1 RSA Key File • SSH-2 RSA Key File (PEM Encoded) • SSH-2 Digital Signature Algorithm (DSA) Key File (PEM Encoded) 320 Managing Images and Files Table 13-1. Files to Manage File Action Description SSL certificate files Download Contains information to encrypt, authenticate, and validate HTTPS sessions. The switch supports the following files for SSL: • SSL Trusted Root Certificate File (PEM Encoded) • SSL Server Certificate File (PEM Encoded) • SSL Diffie-Hellman Weak Encryption Parameter File (PEM Encoded) • SSL Diffie-Hellman Strong Encryption Parameter File (PEM Encoded) IAS Users Download List of Internal Authentication Server (IAS) users for IEEE 802.1X authentication. For more information, see What is the Internal Authentication Server? Why Is File Management Needed? This section provides some reasons why you might choose to manage various files. Image Files The switch can store two firmware images, but only one is active. The other image file is a backup image. By default, the switch has only one image. You might copy an image or download an image to the switch for the following reasons: • To create a backup image • To upgrade the firmware as new images become available Configuration Files Configuration files contain the CLI commands that change the switch from its default configuration. The switch can maintain three separate configuration files: startup-config, running-config, and backup-config. The switch loads the startup-config file when the switch boots. Any configuration Managing Images and Files 321 changes that take place after the boot process completes are written to the running-config file. The backup-config file does not exist until you explicitly create one by copying an existing configuration file to the backup-config file or downloading a backup-config file to the switch. You can also create configuration scripts, which are text files that contains CLI commands. NOTE: You must use the CLI to manage configuration scripts. The configuration scripting feature is not available from the web interface. When you apply (run) a configuration script on the switch, the commands in the script are executed in the order in which they are written as if you were typing them into the CLI. The commands that are executed in the configuration script are added to the running-config file. You might upload a configuration file from the switch to a remote server for the following reasons: • To create a backup copy • To use the configuration file on another switch • To manually edit the file You might download a configuration file from a remote server to the switch for the following reasons: • To restore a previous configuration • To load the configuration copied from another switch • To load the same configuration file on multiple switches Use a text editor to open a configuration file and view or change its contents. SSH/SSL Files If you use OpenManage Switch Administrator to manage the switch over an HTTPS connection, you must copy the appropriate certificate files to the switch. If you use the CLI to manage the switch over an SSH connection, you must copy the appropriate key files to the switch. 322 Managing Images and Files What Methods Are Supported for File Management? You can use any of the following protocols to download files from a remote system to the switch or to upload files from the switch to a remote system: • TFTP • SFTP • SCP • FTP • HTTP (Web only) • HTTPS (Web only) You can also copy files between the file system on the internal flash and a USB flash drive that is connected to the external USB port. What Factors Should Be Considered When Managing Files? Uploading and Downloading Files To use TFTP, SFTP, SCP, or FTP for file management, you must provide the IP address of the remote system that is running the appropriate server (TFTP, SFTP, SCP or FTP). Make sure there is a route from the switch to the remote system. You can use the ping command from the CLI to verify that a route exists between the switch and the remote system. If you are downloading a file from the remote system to the switch, be sure to provide the correct path to the file and the correct file name. Managing Images When you download a new image to the switch, it overwrites the backup image, if it exists. To use the new image, you must activate it and reload the switch. The image that was previously the active image becomes the backup image after the switch reloads. If you upgrade to a newer image and find that it is not compatible with your network, you can revert to the original image. If you activate a new image and reload the switch, and the switch is unable to complete the boot process due to a corrupt image or other problem, you can use the boot menu to activate the backup image. You must be connected to the switch through the console port to access the boot menu. The image files may contain firmware for the PHY processors on the switch. The PHY Managing Images and Files 323 firmware may be updated to the firmware version supported by the switch firmware during the boot process or, in the case of switches that support the hot swap of cards, when the card is inserted into the switch. Editing and Downloading Configuration Files Each configuration file contains a list of executable CLI commands. The commands must be complete and in a logical order, as if you were entering them by using the switch CLI. When you download a startup-config or backup-config file to the switch, the new file replaces the previous version. To change the running-config file, you execute CLI commands either by typing them into the CLI or by applying a configuration script with the script apply command. The startup-config and backup-config files can also be applied to the running-config by using the script apply command. Creating and Applying Configuration Scripts When you use configuration scripting, keep the following considerations and rules in mind: • The application of scripts is partial if the script fails. For example, if the script executes four of ten commands and the script fails, the script stops at four, and the final six commands are not executed. • Scripts cannot be modified or deleted while being applied. • Validation of scripts checks for syntax errors only. It does not validate that the script will run. • The file extension must be .scr. • A maximum of seven scripts are allowed on the switch. • The combined size of all script files on the switch cannot exceed 2 MB. • The maximum number of configuration file command lines is 2000. You can type single-line annotations in the configuration file to improve script readability. The exclamation point (!) character flags the beginning of a comment. The comment flag character can begin anywhere within a single line, and all input following this character to the end of the line is ignored. Any line in the file that begins with the “!” character is recognized as a comment line and ignored by the parser. The following example shows annotations within a file (commands are bold): 324 Managing Images and Files ! Script file for displaying management access show telnet !Displays the information about remote connections ! Display information about direct connections show serial ! End of the script file Managing Files on a Stack Image files downloaded to the master unit of a stack are automatically downloaded to all stack members. If you activate the backup image on the master, it is activated on all units as well so that when you reload the stack, all units use the same image. The running-config, startup-config, and backup-config files, as well as all keys and certificates are synchronized across the stack when the running-config file is saved to the startup-config file. Configuration scripts are not distributed across the stack and only exist on the unit that is the master unit at the time of the file download. Uploading Configuration Files by Using SNMP When you use SNMP to upload a configuration file to a TFTP server, the agentTransferUploadFileName object must be set to the local filename, which is either startup-config or backup-config. How Is the Running Configuration Saved? Changes you make to the switch configuration while the switch is operating are written to the running-config. These changes are not automatically written to the startup-config. When you reload the switch, the startup-config file is loaded. If you reload the switch (or if the switch resets unexpectedly), any settings in the running-config that were not explicitly saved to the startup-config are lost. You must save the running-config to the startupconfig to ensure that the settings you configure on the switch are saved across a switch reset. To save the running-config to the startup-config by using the web-based interface, click (the save icon), which is available at the top of each page. To save the running-config to the startup-config from the CLI, use the write command. Managing Images and Files 325 Managing Images and Files (Web) This section provides information about the OpenManage Switch Administrator pages to use to manage images and files on a PowerConnect 7000 Series switch. For details about the fields on a page, click at the top of the page. File System Use the File System page to view a list of the files on the device and to modify the image file descriptions. To display the File System page, click System → File Management → File System in the navigation panel. Figure 13-1. File System 326 Managing Images and Files Active Images Use the Active Images page to set the firmware image to use when the switch boots. If you change the boot image, it does not become the active image until you reset the switch. To display the Active Images page, click System → File Management → Active Images in the navigation panel. Figure 13-2. Active Images Managing Images and Files 327 USB Flash Drive Use the USB Flash Drive page to view information about a USB flash drive connected to the USB port on the front panel of the switch. The page also displays information about the files stored on the USB flash drive. To safely remove the USB flash drive from the USB port, click Unmount USB before removing the drive. To display the USB Flash Drive page, click System → File Management → USB Flash Drive in the navigation panel. Figure 13-3. USB Flash Drive 328 Managing Images and Files File Download Use the File Download page to download image (binary) files, SSH and SSL certificates, IAS User files, and configuration (ASCII), files from a remote server to the switch. To display the File Download page, click System → File Management → File Download in the navigation panel. Figure 13-4. File Download Downloading Files To download a file to the switch: 1 Open the File Download page. 2 Select the type of file to download to the switch. 3 Select the transfer mode. Managing Images and Files 329 If you select a transfer mode that requires authentication, additional fields appear in the Download section. If you select HTTP as the download method, some of the fields are hidden. NOTE: If you are using HTTPS to manage the switch, the download method will be HTTPS. 4 To download using HTTP, click Browse and select the file to download, then click Apply. 5 To download using any method other than HTTP, enter the IP address of the server that contains the file to download, the name of the file and the path on the server where it is located. For SFTP and SCP, provide the user name and password. 6 Click Apply to begin the download. NOTE: After you start a file download, the page refreshes and a transfer status field appears to indicate the number of bytes transferred. The web interface is blocked until the file download is complete. Figure 13-5. File Download in Progress 7 The file is downloaded to the switch. 330 Managing Images and Files File Upload Use the File Upload to Server page to upload configuration (ASCII), image (binary), IAS user, operational log, and startup log files from the switch to a remote server. To display the File Upload to Server page, click System → File Management → File Upload in the navigation panel. Figure 13-6. File Upload Uploading Files To upload a file from the switch to a remote system: 1 Open the File Upload page. 2 Select the type of file to download to the remote server. 3 Select the transfer mode. If you select a transfer mode that requires authentication, additional fields appear in the Upload section. If you select HTTP as the upload method, some of the fields are hidden. Managing Images and Files 331 NOTE: If you are using HTTPS to manage the switch, the download method will be HTTPS. 4 To upload by using HTTP, click Apply. A dialog box opens to allow you to open or save the file. Figure 13-7. File Upload 5 To upload by using any method other than HTTP, enter the IP address of the server and specify a name for the file. For SFTP and SCP, provide the user name and password. 6 Click Apply to begin the upload. NOTE: For some file uploads and methods, the page refreshes and a transfer status field appears to indicate the number of bytes transferred. The web interface is blocked until the file upload is complete. 7 The file is uploaded to the specified location on the remote server. 332 Managing Images and Files Copy Files Use the Copy Files page to: • Copy the active firmware image to one or all members of a stack. • Copy the running, startup, or backup configuration file to the startup or backup configuration file. • Restore the running configuration to the factory default settings. To display the Copy Files page, click System → File Management → Copy Files in the navigation panel. Figure 13-8. Copy Files Managing Images and Files 333 Managing Images and Files (CLI) This section provides information about the commands you use to upload, download, and copy files to and from the PowerConnect 7000 Series switch. For more information about these commands, see the PowerConnect 7000 Series CLI Reference Guide at support.dell.com/manuals. It also describes the commands that control the Auto Configuration feature. NOTE: Upload, download, and copy functions use the copy command. The basic syntax for the command is copy source destination. This section shows several different ways to use the copy command. Downloading and Activating a New Image (TFTP) Beginning in Privileged EXEC mode, use the following commands to download a new firmware image to the switch and to make it the active image. This example shows how to use TFTP to download the image. Command Purpose copy tftp://{ip-address| hostname}/path/filename image Use TFTP to download the firmware image at the specified source to the non-active image. show version View information about the currently active image. filedescr {image1 | image2} description Add a description to the image files. boot system {image1 | image2} Set the image to use as the boot (active) image after the switch resets. reload Reboot the switch to make the new image the active image. If the image file is in the TFTP file system root (download path), you do not need to specify the path in the command. You are prompted to verify that you want to continue. 334 Managing Images and Files Managing Files in Internal Flash Beginning in Privileged EXEC mode, use the following commands to copy, rename, delete and list the files in the internal flash. Command Purpose dir List the files in the flash file system. copy flash://filename usb://filename Copy a file from the internal flash to a USB flash drive. Use the dir command to see a list of the files that can be copied from the internal flash. Make sure a flash drive has been inserted in the USB port on the front panel before executing the command. rename current_name new_name Rename a file in flash. delete filename Remove the specified file. erase {startup-config | Erase the startup configuration, the backup configuration backup-image | backup- or the backup image. config} copy startup-config backup-config Save the startup configuration to the backup configuration file. copy running-config startup-config Copy the current configuration to the startup configuration. This saves the current configuration to NVRAM. show startup-config View the contents of the startup-config file show running-config View the contents of the running-config file Managing Images and Files 335 Managing Files on a USB Flash Device Beginning in Privileged EXEC mode, use the following commands to manage files that are on a USB device that is plugged into the USB flash port on the front panel of the switch. Command Purpose show usb device Display USB flash device details dir usb Display USB device contents and memory statistics copy usb://filename Copy the specified file from the USB flash device to the {backup-config | image specified file in internal flash. | running-config | script filename| startup-config | filename unmount usb Make the USB flash device inactive. Uploading a Configuration File (SCP) Beginning in Privileged EXEC mode, use the following commands to upload a configuration file from the switch to a remote system by using SCP. Command Purpose copy file scp://user@{ip- Adds a description to an image file. address|hostname}/path The file can be one of the following files: /file-name • backup-config • image • operational-log • running-config • script file-name • startup-config • startup-log Password entry 336 After you enter the copy command, the CLI prompts you for the password associated with the username. Managing Images and Files Managing Configuration Scripts (SFTP) Beginning in Privileged EXEC mode, use the following commands to download a configuration script from a remote system to the switch, validate the script, and activate it. NOTE: The startup-config and backup-config files are essentially configuration scripts and can be validated and applied by using the commands in this section. Command Purpose Downloads the specified script from the remote server to copy sftp://user@{ipaddress|hostname}/path the switch. /file-name script dest- name Password entry After you enter the copy command, the CLI prompts you for the password associated with the username. script validate script- Checks the specified script for syntax errors. name The script is automatically validated when you download it to the switch. You can validate again with this command. script list View the list of available scripts. name script activate script- Executes the commands within the script in order. The configuration changes in the script are applied to the running configuration. script show script-name View the contents of the specified script. Managing Images and Files 337 File and Image Management Configuration Examples This section contains the following examples: • Upgrading the Firmware • Managing Configuration Scripts Upgrading the Firmware This example shows how to download a firmware image to the switch and activate it. The TFTP server in this example is PumpKIN, an open source TFTP server running on a Windows system. • TFTP server IP address: 10.27.65.103 • File path: \image • File name: dell_0308.stk Use the following steps to prepare the download, and then download and upgrade the switch image. 1 Check the connectivity between the switch and the TFTP server. console#ping 10.27.65.103 Pinging 10.27.65.103 with 0 bytes of data: Reply Reply Reply Reply From From From From 10.27.65.103: 10.27.65.103: 10.27.65.103: 10.27.65.103: icmp_seq icmp_seq icmp_seq icmp_seq = = = = 0. 1. 2. 3. time time time time <10 <10 <10 <10 msec. msec. msec. msec. ----10.27.65.103 PING statistics---4 packets transmitted, 4 packets received, 0% packet loss round-trip (msec) min/avg/max = <10/<10/<10 2 Copy the image file to the appropriate directory on the TFTP server. In this example, the TFTP root directory is C:\My Documents\Other\Downloads\TFTP., so the file path is images. 338 Managing Images and Files Figure 13-9. Image Path 3 View information about the current image. console#show version Image Descriptions image1 :default image image2 : Images currently available on Flash ------- ------------ ------------ --------------- -------------unit image1 image2 current-active next-active ------- ------------ ------------ --------------- -------------1 4.1.0.7 5.0.0.8 image1 image1 4 Download the image to the switch. After you execute the copy command, you must verify that you want to start the download. The downloaded image replaces the currently inactive image, which may be image1 or image2. console#copy tftp://10.27.65.103/images/dell_0308.stk image Mode........................................... Set TFTP Server IP............................. TFTP Path...................................... TFTP Filename.................................. Data Type...................................... TFTP 10.27.65.103 images/ dell_0308.stk Code Managing Images and Files 339 Destination Filename........................... image Management access will be blocked for the duration of the transfer Are you sure you want to start? (y/n)y 5 Activate the new image (image2) so that it becomes the active image after the switch resets. console#boot system image2 Activating image image2.. 6 View information about the current image. console#show bootvar Image Descriptions image1 : image2 : Images currently available on Flash ------- ------------ ------------ --------------- -------------unit image1 image2 current-active next-active ------- ------------ ------------ --------------- -------------1 4.1.0.7 5.0.0.8 image1 image2 7 Copy the running configuration to the startup configuration to save the current configuration to NVRAM. console#copy running-config startup-config This operation may take a few minutes. Management interfaces will not be available during this time. Are you sure you want to save? (y/n)y Configuration Saved! 8 Reset the switch to boot the system with the new image. console#reload Are you sure you want to continue? (y/n)y 340 Managing Images and Files Reloading all switches... Managing Configuration Scripts This example shows how to create a configuration script that adds three hostname-to-IP address mappings to the host table. To configure the switch: 1 Open a text editor on an administrative computer and type the commands as if you were entering them by using the CLI. Figure 13-10. Create Config Script 2 Save the file with an *.scr extension and copy it to the appropriate directory on your TFTP server. 3 Download the file from the TFTP server to the switch. console#copy tftp://10.27.65.103/labhost.scr script labhost.scr Mode........................................... Set TFTP Server IP............................. TFTP Path...................................... TFTP Filename.................................. TFTP 10.27.65.103 ./ labhost.scr Managing Images and Files 341 Data Type...................................... Config Script Destination Filename........................... labhost.scr Management access will be blocked for the duration of the transfer 4 After you confirm the download information and the script successfully downloads, it is automatically validated for correct syntax. Are you sure you want to start? (y/n) y 135 bytes transferred Validating configuration script... configure exit configure ip host labpc1 192.168.3.56 ip host labpc2 192.168.3.58 ip host labpc3 192.168.3.59 Configuration script validated. File transfer operation completed successfully. 5 Run the script to execute the commands. console#script apply labhost.scr Are you sure you want to apply the configuration script? (y/n)y configure exit configure ip host labpc1 192.168.3.56 ip host labpc2 192.168.3.58 ip host labpc3 192.168.3.59 Configuration script 'labhost.scr' applied. 342 Managing Images and Files 6 Verify that the script was successfully applied. console#show hosts Host name: test Name/address lookup is enabled Name servers (Preference order): 192.168.3.20 Configured host name-to-address mapping: Host Addresses ------------------------ -----------------------labpc1 192.168.3.56 labpc2 192.168.3.58 labpc3 192.168.3.59 Managing Files by Using the USB Flash Drive In this example, the administrator copies the backup image to a USB flash drive before overwriting the backup image on the switch with a new image. The administrator also makes a backup copy of the running-config by uploading it to a USB flash drive. After the backups are performed, the administrator downloads a new image from the USB flash drive to the switch to prepare for the upgrade. This example assumes the new image is named new_img.stk and has already been copied from an administrative host onto the USB flash drive. To configure the switch: 1 Insert the USB flash drive into the USB port on the front panel of the switch. The USB flash drive is automatically mounted. 2 Copy the backup image from the switch to the USB flash drive. console#copy image usb://img_backup.stk Mode................................... unknown Data Type.............................. Code Management access will be blocked for the duration of the transfer Are you sure you want to start? (y/n) y Managing Images and Files 343 3 Copy the running-config to the USB flash drive. console#copy running-config usb://rc_backup.scr Mode............................. unknown Data Type........................ Config Script Source Filename.................. temp-config.scr Management access will be blocked for the duration of the transfer Are you sure you want to start? (y/n) y 4 Download the new image from the USB flash drive to the switch. The image overwrites the image that is not currently active. console#copy usb://new_image.stk image Mode................................... unknown Data Type.............................. Code Management access will be blocked for the duration of the transfer Are you sure you want to start? (y/n) y 5 To activate the new image after it has been successfully downloaded to the switch, follow the procedures described in Upgrading the Firmware, starting with step 5. 344 Managing Images and Files 14 Automatically Updating the Image and Configuration The topics covered in this chapter include: • Auto Configuration Overview • What Are the Dependencies for DHCP Auto Configuration? • Default Auto Configuration Values • Managing Auto Configuration (Web) • Managing Auto Configuration (CLI) • Auto Configuration Example Auto Configuration Overview The Auto Configuration feature can automatically update the firmware image and obtain configuration information when the switch boots. Auto Configuration begins the automatic download and installation process when the switch or stack master is initialized and no configuration file (startupconfig) is found, or when the switch boots and loads a saved configuration that has Auto Configuration enabled. Auto Configuration is enabled by default. Allow downgrade is also enabled by default. The Auto Configuration feature includes two components: • USB Auto Configuration • DHCP Auto Install If no configuration file is found and the Auto Configuration feature is enabled (which it is by default), the Auto Configuration process begins. If a USB device is connected to the PowerConnect switch USB port and contains the appropriate file, the switch uses the USB Auto Configuration feature to update the configuration or image. If the USB Auto Configuration fails - Auto Image and Configuration Update 345 either because it is disabled, no USB storage device is present, or no configuration or images files are present on the USB storage device, the switch uses the DHCP Auto Install process. NOTE: Neither USB Configuration nor Auto Install is invoked if a valid configuration file is on the switch. What Is USB Auto Configuration? You can use the USB Auto Configuration feature to configure or upgrade one or more switches that have not been previously configured, such as when you deploy new switches. Before you deploy the switch, you perform the following steps: 1 Create a text file that contains IP addresses (and/or MAC addresses) and file names that are parsed and used by this feature. The optional MAC address used to identify the switch is the MAC address of the base MAC address of the switch, although the feature will accept any of the switch MAC addresses (see "Switch Addresses" on page 100 for further information). Refer to the example below for an explanation of the file format. 2 Copy the file onto a USB device. 3 Insert the USB device into the front-panel USB port on the PowerConnect switch. When the Auto Configuration process starts and a factory default or empty configuration file is present on the switch, the feature automatically searches a plugged-in USB device for information. What Files Does USB Auto Configuration Use? The USB Auto Configuration feature uses the following file types: • *.setup file for initial switch configuration • *.text file for configuration information • *.stk file for software image installation The Auto Configuration file searches the USB device for a file with a *.setup extension. If only one .setup file is present, the switch uses the file. When multiple *.setup files are present, the switch uses only the powerconnnect.setup file. If no powerconnect.setup file is available, the 346 Auto Image and Configuration Update switch checks for a file with a *.text configuration file and a *.stk image file. If multiple .text files exist, the switch uses the powerconnect.text file. If multiple *.stk files are present, the switch uses the image with the highest (most recent) version. Finally, if no *.setup, *.text, or *.stk files are found, the switch proceeds to the DHCP Auto Configuration process. Auto Image and Configuration Update 347 How Does USB Auto Configuration Use the Files on the USB Device? The *.setup file can include the following information: • MAC address of the switch • Configuration file name • Image file name • IP address MAC Address Lookup The MAC address should be on the same line as the configuration file and/or image file name to allow a specific switch (identified by its MAC address) to be associated with a specific config file or image. If an IP address also exists on the line, this indicates a previous binding and requires this IP address to be configured for the management IP address. IP Address Lookup If the switch MAC address is not found within the .setup text file, the first line that starts with an IP address will be used by the switch to assign the management IP address/netmask. The IP address line should include the configuration filename and/or image filename for the switch. This method allows a group of IP addresses to be handed out without regard to the specific switch identified by the MAC address. A switch will mark a line as invalid if it is read and failed to properly parse if, for example, it contains an invalid configuration, a duplicate IP address or an image file name that is not available. If the *.setup file contains IP addresses but no file names, the management IP address will be assigned, and then the feature will search the USB device for files with the .text and .stk extensions, which indicates that all switches will be using the same configuration file and/or image on the USB device. This method allows different IP addresses to be assigned, but the same configuration file or image is downloaded to multiple switches. After the current switch has been configured and/or upgraded and the completion message is displayed on the switch, the current line in the *.setup text file will be marked as used. This allows you to use the *.setup file for additional switches without manually changing the file. You can then remove the USB device and insert it into the next switch to begin the process again. Also, the switch MAC address of the switch that has been automatically 348 Auto Image and Configuration Update configured is added to the beginning of the line (if no MAC address was specified in the file) for lines using the IP address lookup method so that the MAC and IP address combinations are recorded within the *.setup file for future use bindings. At the start of the next USB auto download, if all lines in the *.setup file are marked as already “in-use” or “invalid,” and there is no MAC address match for a switch, the process will halt, and a message similar to the following is displayed on the console: <###> APR 22 08:32:43 Error: Auto Configuration has terminated due to there being no more lines available for use within the USB file “XXXXX.setup”. Configuration File The *.text configuration file identified in the *.setup file contains the running-config to be loaded on to the switch. The configuration file specified in the *.setup file should exist on the USB device. For information about the format and contents of the *.text file, see Editing and Downloading Configuration Files. Image File If the Auto Configuration process includes a switch image upgrade, the name of the image file should be included in the *.setup file. The specified image file should exist on the USB device. What Is the Setup File Format? The setup file must have a *.setup extension or this part of the feature will never begin. If there are multiple .setup files located on the USB device, the powerconnect.setup file will take precedence. A line in the setup file that uses the MAC address and static IP address of a switch is as follows: MAC_address IP_Address Subnet_Mask Config_File Image_File The following example shows a *.setup example for two switches: 2180.c200.0010 192.168.0.10 255.255.255.0 switch-A.text PC7000vR.5.4.1.stk 3380.c200.0011 192.168.0.11 255.255.255.0 switch-B.text PC7000vR.5.4.1.stk Auto Image and Configuration Update 349 If the switches are to be assigned a static IP address included in a specified configuration file (.text) or by a DHCP server, the entries in the *.setup file that assigns a specific configuration file and image to each switch has the following format: MAC_Address Config_File Image_File switch-Y.text switch-Z.text PC7000vR.5.4.1.stk PC7000vR.5.4.1.stk For example: 0180.c200.0010 1180.c200.0011 After a line has been read and implemented by the Auto Configuration feature, it automatically adds “in-use” to the end of the line to ensure that the information is not used for the next switch. To replicate the entire USB auto configuration process, the “in-use” statements from the .setup file need to be removed. Then, if the process is restarted, the MAC address/IP address combinations will be ensured for any switch that has previously attempted upgrade and all other switch upgrades can take place as if for the first time. What Is the DHCP Auto Configuration Process? If the USB Auto Configuration fails or is not used, the switch can use a DHCP server to obtain configuration information from a TFTP server. DHCP Auto Configuration is accomplished in three phases: 1 Assignment or configuration of an IP address for the switch 2 Assignment of a TFTP server 3 Obtaining a configuration file for the switch from the TFTP server Auto Configuration is successful when an image or configuration file is downloaded to the switch or stack master from a TFTP server. NOTE: The downloaded configuration file is not automatically saved to startupconfig. You must explicitly issue a save request (copy running-config startupconfig) in order to save the configuration. 350 Auto Image and Configuration Update Obtaining IP Address Information DHCP is enabled by default on the Out-of-Band (OOB) interface. If an IP address has not been assigned, the switch issues requests for an IP address assignment. A network DHCP server returns the following information: • IP address and subnet mask to be assigned to the interface • IP address of a default gateway, if needed for IP communication After an IP address is assigned to the switch, if a hostname is not already assigned, Auto Configuration issues a DNS request for the corresponding hostname. This hostname is also displayed as the CLI prompt (as in response to the hostname command). Obtaining Other Dynamic Information The following information is also processed and may be returned by a BOOTP or DHCP server: • Name of configuration file (the file field in the DHCP header or option 67) to be downloaded from the TFTP server. • Identification of the TFTP server providing the file. The TFTP server can be identified by name or by IP address as follows: – hostname: DHCP option 66 or the sname field in the DHCP header) – IP address: DHCP option 150 or the siaddr field in the DHCP header When a DHCP OFFER identifies the TFTP server more than once, the DHCP client selects one of the options in the following order: sname, option 66, option 150, siaddr. If the TFTP server is identified by hostname, a DNS server is required to translate the name to an IP address. The DHCP client on the switch also processes the name of the text file (option 125, the V-I vendor-specific Information option) which contains the path to the image file. Auto Image and Configuration Update 351 Obtaining the Image Auto Configuration attempts to download an image file from a TFTP server only if no configuration file was found in the internal flash or a USB drive, or even with a saved configuration file that has Auto Configuration enabled. The network DHCP server returns a DHCP OFFER message with option 125. When configuring the network DHCP server for image downloads, you must include Option 125 and specify the Dell Enterprise Number, 674. Within the Dell section of option 125, sub option 5 must specify the path and name of a file on the TFTP server. This file is not the image file itself, but rather a text file that contains the path and name of the image file. Upon receipt of option 125, the switch downloads the text file from the TFTP server, reads the name of the image file, and downloads the image file from the TFTP server. After the switch successfully downloads and installs the new image, it automatically reboots. The download or installation might fail for one of the following reasons: • The path or filename of the image on the TFTP server does not match the information specified in DHCP option 125. • The downloaded image is the same as the current image. • The validation checks, such as valid CRC Checksum, fails. If the download or installation was unsuccessful, a message is logged. NOTE: In stack of switches, the downloaded image is pushed to all members attached to the stack at the time of download. For members who join the stack after the download, the Stack Firmware Synchronization feature will push the latest image to all members. 352 Auto Image and Configuration Update Obtaining the Configuration File If the DHCP OFFER identifies a configuration file, either as option 67 or in the file field of the DHCP header, the switch attempts to download the configuration file. NOTE: The configuration file is required to have a file type of *.cfg. The TFTP client makes three unicast requests. If the unicast attempts fail, or if the DHCP OFFER did not specify a TFTP server address, the TFTP client makes three broadcast requests. If the DHCP server does not specify a configuration file or download of the configuration file fails, the Auto Configuration process attempts to download a configuration file with the name dell-net.cfg. The switch unicasts or broadcasts TFTP requests for a network configuration file in the same manner as it attempts to download a host-specific configuration file. The default network configuration file consists of a set of IP address-tohostname mappings, using the command ip host hostname address. The switch finds its own IP address, as learned from the DHCP server, in the configuration file and extracts its hostname from the matching command. If the default network configuration file does not contain the switch's IP address, the switch attempts a reverse DNS lookup to resolve its hostname. A sample dell-net.cfg file follows: config ... ip host switch1 192.168.1.10 ip host switch2 192.168.1.11 ... exit Once a hostname has been determined, the switch issues a TFTP request for a file named hostname.cfg , where hostname is the first thirty-two characters of the switch's hostname. If the switch is unable to map its IP address to a hostname, Auto Configuration sends TFTP requests for the default configuration file host.cfg. Auto Image and Configuration Update 353 Table 14-1 summarizes the config files that may be downloaded and the order in which they are sought. Table 14-1. Configuration File Possibilities Order Sought File Name Description Final File Sought 1 bootfile.cfg Host-specific config file, ending in a *.cfg file extension Yes 2 dell-net.cfg Default network config file No 3 hostname.cfg Host-specific config file, associated with hostname. Yes 4 host.cfg Default config file Yes Table 14-2 displays the determining factors for issuing unicast or broadcast TFTP requests. Table 14-2. TFTP Request Types TFTP Server Address Available Host-specific Switch Config Filename Available TFTP Request Method Yes Yes Issue a unicast request for the host-specific router config file to the TFTP server Yes No Issue a unicast request for a default network or router config file to the TFTP server No Yes Issue a broadcast request for the hostspecific router config file to any available TFTP server No No Issue a broadcast request for the default network or router config file to any available TFTP server 354 Auto Image and Configuration Update Monitoring and Completing the DHCP Auto Configuration Process When the switch boots and triggers an Auto Configuration, a message displays on the console screen to indicate that the process is starting. After the process completes, the Auto Configuration process writes a log message. When Auto Configuration has successfully completed, you can execute a show running-config command to validate the contents of configuration. Saving a Configuration The Auto Configuration feature includes an AutoSave capability that allows the downloaded configuration to be automatically saved; however, AutoSave is disabled by default. If AutoSave has not been enabled, you must explicitly save the downloaded configuration in nonvolatile memory on the stack master. This makes the configuration available for the next reboot. In the CLI, this is performed by issuing a write command or copy running-config startup-config command and should be done after validating the contents of saved configuration. Stopping and Restarting the Auto Configuration Process You can terminate the Auto Configuration process at any time before the image or configuration file is downloaded. This is useful when the switch is disconnected from the network. Termination of the Auto Configuration process ends further periodic requests for a host-specific file. The Auto Configuration process automatically starts after a reboot if the configuration file is not found on the switch. The configuration file will not be found if it has never been saved on the switch, or if you issue a command to erase the configuration file (clear config or erase startup-config). Managing Downloaded Config Files The configuration files downloaded by Auto Configuration are stored in the nonvolatile memory as .scr files. The files may be managed (viewed or deleted) along with files downloaded by the configuration scripting utility. A file is not automatically deleted after it is downloaded. The file does not take effect upon a reboot unless you explicitly save the configuration (the saved configuration takes effect upon reboot). If you do not save the configuration downloaded by the Auto Configuration feature, the Auto Configuration process occurs again on a subsequent reboot. This may result in one of the previously downloaded files being overwritten. Auto Image and Configuration Update 355 What Are the Dependencies for DHCP Auto Configuration? The Auto Configuration process from TFTP servers depends upon the following network services: 356 • A DHCP server must be configured on the network with appropriate services. • An image file and a text file containing the image file name for the switch must be available from a TFTP server if DHCP image download is desired. • A configuration file (either from bootfile (or) option 67 option) for the switch must be available from a TFTP server. • The switch must be connected to the network and have a Layer 3 interface that is in an UP state. • A DNS server must contain an IP address to hostname mapping for the TFTP server if the DHCP server response identifies the TFTP server by name. • A DNS server must contain an IP address to hostname mapping for the switch if a .cfg file is to be downloaded. • If a default gateway is needed to forward TFTP requests, an IP helper address for TFTP needs to be configured on the default gateway. Auto Image and Configuration Update Default Auto Configuration Values Table 14-3 describes the Auto Configuration defaults. Table 14-3. Auto Configuration Defaults Feature Default Description Auto Install Mode Enabled When the switch boots and no saved configuration is found, the Auto Configuration automatically begins. Retry Count 3 When the DHCP or BootP server returns information about the TFTP server and bootfile, the switch makes three unicast TFTP requests for the specified bootfile. If the unicast attempts fail or if a TFTP server address was not provided, the switch makes three broadcast requests to any available TFTP server for the specified bootfile. AutoSave Disabled If the switch is successfully auto-configured, the running configuration is not saved to the startup configuration. AutoReboot Enabled After an image is successfully downloaded during the Auto Configuration process, the switch automatically reboots and makes the downloaded image the active image. Auto Image and Configuration Update 357 Managing Auto Configuration (Web) This section provides information about the OpenManage Switch Administrator pages to use to manage images and files on a PowerConnect 7000 Series switch. For details about the fields on a page, click at the top of the page. Auto-Install Configuration Use the Auto-Install Configuration page to allow the switch to obtain network information (such as the IP address and subnet mask) and automatically download a host-specific or network configuration file during the boot process if no startup-config file is found. To display the Auto Configuration page, click System → General → AutoInstall Configuration in the navigation panel. Figure 14-1. Auto-Install Configuration 358 Auto Image and Configuration Update Managing Auto Configuration (CLI) This section provides information about the commands you manage the Auto-Install Configuration feature on the switch. For more information about these commands, see the PowerConnect 7000 Series CLI Reference Guide at support.dell.com/manuals. Managing Auto Configuration Beginning in Privileged EXEC mode, use the following commands to manually activate the Auto Configuration process and download a configuration script from a remote system to the switch, validate the script, and activate it. NOTE: The Auto Configuration feature begins automatically when the switch is booted and no startup-config file is found or if the system boots and finds the boot host dhcp command in the startup-config file. Command Purpose configure Enter Global Configuration mode. boot autoinstall start Enable the Auto Configuration feature on the switch. boot host dhcp Enable Auto Configuration for the next reboot cycle. The command does not change the current behavior of Auto Configuration, but it does save the command to NVRAM. boot host autosave Allow the switch to automatically save the configuration file downloaded to the switch by the Auto Configuration feature. boot host retrycount Specify the number of attempts to download the file (by sending unicast TFTP requests, and if unsuccessful, broadcast TFTP requests) specified in the response from the DHCP server. retries The range for retries is 1–3. boot host autoreboot Allow the switch to automatically reboot when the image is successfully downloaded through the Auto Configuration feature. exit Exit to Privileged Exec mode. show boot Displays the current status of the Auto Configuration process. Auto Image and Configuration Update 359 Auto Configuration Example A network administrator is deploying three PowerConnect switches and wants to quickly and automatically install the latest image and a common configuration file that configures basic settings such as VLAN creation and membership, RADIUS server settings, and 802.1X information. The configuration file also contains the command boot host autosave so that the downloaded configuration is automatically saved to the startup config. This section describes two ways to enable automatic configuration file download: • Enabling USB Auto Configuration and Auto Image Download • Enabling DHCP Auto Configuration and Auto Image Download Enabling USB Auto Configuration and Auto Image Download This example describes how to deploy three switches and automatically install a custom configuration file on the switch and upgrade each switch with the latest software image by using the USB Auto Configuration feature. The switches have the following MAC addresses: • Switch A: 001E.C9AA.AC17 • Switch B: 001E.C9AA.AC20 • Switch C: 001E.C9AA.AC33 To configure each switch with a static IP address, you can include the IP address in the .setup file or in the configuration file (.text) for the switch. Otherwise, the switch can obtain an IP address from a DHCP server on the network. To use USB auto configuration: 1 Create a default config file for each switch. The configuration files are named switchA.txt, switchB.txt, and switchC.txt. For information about creating configuration files, see Managing Images and Files. 2 Copy the configuration files to a USB device. 3 Copy the image file to the device. In this example, the image file that each switch will download is named PC7000vR.5.4.1.stk. 360 Auto Image and Configuration Update 4 Create a setup file named PowerConnect.setup. The setup file contains the following lines: 001E.C9AA.AC17 switchA.txt PC7000vR.5.4.1.stk 001E.C9AA.AC20 switchB.txt PC7000vR.5.4.1.stk 001E.C9AA.AC33 switchC.txt PC7000vR.5.4.1.stk NOTE: This .setup file does not provide the switch with a static IP address. However, the switchA.txt, switchB.txt, and switchC.txt files can contain the commands required to configure a static IP address on each switch. Otherwise, the switch will use DHCP to attempt to acquire an IP address. 5 Copy the PowerConnect.setup file to the USB device. 6 Connect the USB device to Switch A. 7 Connect Switch A to the network. Make sure that a port (OOB port for out-of-band management or any switch port for in-band management) is connected to the network and that a DHCP server is accessible on the network. 8 Insert the USB device into the USB port on the front panel of Switch A. 9 Power on Switch A. When the factory default (empty) configuration file is found, the USB Auto Configuration process begins. The configuration in switchA.txt file is downloaded to the switch, and the management interface acquires network information. After the process completes, a message displays to indicate the status. The PowerConnect.setup file is updated to add the term in-use to the end of the line. The PC7000vR.5.4.1.stk image is also downloaded to the switch. 10 Remove the USB device from Switch A and insert it into Switch B. 11 Repeat the process to connect a port to the network. Power on the switch to begin the USB Auto Configuration process on Switch B. 12 Remove the USB device from Switch B after the process completes, and repeat the steps to perform the USB Auto Configuration process on Switch C. Auto Image and Configuration Update 361 Enabling DHCP Auto Configuration and Auto Image Download If no USB device is connected to the USB port on the PowerConnect switch and no configuration file is found during the boot process, the Auto Configuration feature uses the DHCP Auto Configuration process to download the configuration file to the switch. This example describes the procedures to complete the configuration. To use DHCP auto configuration: 1 Create a default config file for the switches named host.cfg. For information about creating configuration files, see Managing Images and Files. 2 Upload the host.cfg file to the TFTP server. 3 Upload the image file to the TFTP server. 4 Configure an address pool on the DHCP server that contains the following information: a The IP address (yiaddr) and subnet mask (option 1) to be assigned to the interface b The IP address of a default gateway (option 3) c DNS server address (option 6) d Name of config file for each host e Identification of the TFTP server by hostname (DHCP option 66 or the sname field in the DHCP header) or IP address (DHCP option 150 or the siaddr field in the DHCP header) f Name of the text file (option 125, the V-I vendor-specific Information option) that contains the path to the image file. 5 Connect a port (OOB port for out-of-band management or any switch port for in-band management) on each switch to the network. 6 Boot the switches. 362 Auto Image and Configuration Update Monitoring Switch Traffic 15 This chapter describes sFlow features, Remote Monitoring (RMON), and Port Mirroring features. The topics covered in this chapter include: • Traffic Monitoring Overview • Default Traffic Monitoring Values • Monitoring Switch Traffic (Web) • Monitoring Switch Traffic (CLI) • Traffic Monitoring Configuration Examples Traffic Monitoring Overview The switch maintains statistics about network traffic that it handles. It also has embedded technology that collects and sends information about traffic to other devices. PowerConnect 7000 Series switches include support for flowbased monitoring through sFlow and Remote Network Monitoring (RMON) agents. What is sFlow Technology? sFlow is an industry standard technology for monitoring high-speed switched and routed networks. PowerConnect 7000 Series switch software has a builtin sFlow agent that can monitor network traffic on each port and generate sFlow data to an sFlow receiver (also known as a collector). sFlow helps to provide visibility into network activity, which enables effective management and control of network resources. sFlow is an alternative to the NetFlow network protocol, which was developed by Cisco Systems. The switch supports sFlow version 5. As illustrated in Figure 15-1, the sFlow monitoring system consists of sFlow Agents (such as PowerConnect 7000 Series switches) and a central sFlow receiver. sFlow Agents use sampling technology to capture traffic statistics Monitoring Switch Traffic 363 from monitored devices. sFlow datagrams forward sampled traffic statistics to the sFlow Collector for analysis. You can specify up to eight different sFlow receivers to which the switch sends sFlow datagrams. Figure 15-1. sFlow Architecture The advantages of using sFlow are: 364 • It is possible to monitor all ports of the switch continuously, with no impact on the distributed switching performance. • Minimal memory/CPU is required. Samples are not aggregated into a flowtable on the switch; they are forwarded immediately over the network to the sFlow receiver. • The sFlow system is tolerant to packet loss in the network because statistical modeling means the loss is equivalent to a slight change in the sampling rate. • sFlow receiver can receive data from multiple switches, providing a realtime synchronized view of the whole network. • The receiver can analyze traffic patterns based on protocols found in the headers (e.g., TCP/IP, IPX, Ethernet, AppleTalk…). This alleviates the need for a layer 2 switch to decode and understand all protocols. Monitoring Switch Traffic sFlow Sampling The sFlow Agent in the PowerConnect software uses two forms of sampling: • Statistical packet-based sampling of switched or routed Packet Flows • Time-based sampling of counters Packet Flow Sampling and Counter Sampling are performed by sFlow Instances associated with individual Data Sources within an sFlow Agent. Both types of samples are combined in sFlow datagrams. Packet Flow Sampling creates a steady, but random, stream of sFlow datagrams that are sent to the sFlow Collector. Counter samples may be taken opportunistically to fill these datagrams. To perform Packet Flow Sampling, an sFlow Sampler Instance is configured with a Sampling Rate. Packet Flow sampling results in the generation of Packet Flow Records. To perform Counter Sampling, an sFlow Poller Instance is configured with a Polling Interval. Counter Sampling results in the generation of Counter Records. sFlow Agents collect Counter Records and Packet Flow Records and send them as sFlow datagrams to sFlow Collectors. Packet Flow Sampling Packet Flow Sampling, carried out by each sFlow instance, ensures that any packet observed at a Data Source has an equal chance of being sampled, irrespective of the Packet Flow(s) to which it belongs. Packet Flow Sampling is accomplished as follows: • A packet arrives on an interface. • The Network Device makes a filtering decision to determine whether the packet should be dropped. • If the packet is not filtered (dropped) a destination interface is assigned by the switching/routing function. • A decision is made on whether or not to sample the packet. The mechanism involves a counter that is decremented with each packet. When the counter reaches zero a sample is taken. • When a sample is taken, the counter indicating how many packets to skip before taking the next sample is reset. The value of the counter is set to a random integer where the sequence of random integers used over time is the Sampling Rate. Monitoring Switch Traffic 365 Counter Sampling The primary objective of Counter Sampling is to efficiently, periodically export counters associated with Data Sources. A maximum Sampling Interval is assigned to each sFlow instance associated with a Data Source. Counter Sampling is accomplished as follows: • sFlow Agents keep a list of counter sources being sampled. • When a Packet Flow Sample is generated the sFlow Agent examines the list and adds counters to the sample datagram, least recently sampled first. Counters are only added to the datagram if the sources are within a short period, 5 seconds say, of failing to meet the required Sampling Interval. • Periodically, say every second, the sFlow Agent examines the list of counter sources and sends any counters that must be sent to meet the sampling interval requirement. The set of counters is a fixed set. What is RMON? Like sFlow, RMON is a technology that enables the collection and analysis of a variety of data about network traffic. PowerConnect 7000 Series switch software includes an RMON probe (also known as an RMON agent) that collect information and analyze packets. The data that is collected is defined in the RMON MIB, RFC 2819. RMON is defined in an Internet Engineering Task Force (IETF) specification and is an extension of the SNMP MIB. You can view the RMON information locally on the switch or by using a generic RMON console on a network management station (NMS). SNMP does not need to be configured on the switch to view the RMON data locally. However, if you use a management station to view the RMON data that the switch collects and analyzes, you must configure the following SNMP settings: • Set up the SNMP community string to be used by the SNMP manager at a given IP address. • Specify the network management system IP address or permit management access from all IP addresses. For more information about configuring SNMP, see "Configuring SNMP" on page 283. 366 Monitoring Switch Traffic The RMON agent in the switch supports the following groups: • Group 1—Statistics. Contains cumulative traffic and error statistics. • Group 2—History. Generates reports from periodic traffic sampling that are useful for analyzing trends. • Group 3 —Alarm. Enables the definition and setting of thresholds for various counters. Thresholds can be passed in either a rising or falling direction on existing MIB objects, primarily those in the Statistics group. An alarm is triggered when a threshold is crossed and the alarm is passed to the Event group. The Alarm requires the Event Group. • Group 9 —Event. Controls the actions that are taken when an event occurs. RMON events occur when: – A threshold (alarm) is exceeded – There is a match on certain filters. NOTE: The switch supports RMON1. What is Port Mirroring? Port mirroring is used to monitor the network traffic that a port sends and receives. The Port Mirroring feature creates a copy of the traffic that the source port handles and sends it to a destination port. The source port is the port that is being monitored. The destination port is monitoring the source port. The destination port is where you would connect a network protocol analyzer to learn more about the traffic that is handled by the source port. A port monitoring session includes one or more source ports that mirror traffic to a single destination port. The PowerConnect 7000 Series switches support a single port monitoring session. LAGs (port channels) cannot be used as the source or destination ports. For each source port, you can specify whether to mirror ingress traffic (traffic the port receives, or RX), egress traffic (traffic the port sends, or TX), or both ingress and egress traffic. NOTE: You can create a DiffServ policy class definition that mirrors specific types of traffic to a destination port. For more information, see "Configuring Differentiated Services" on page 1101. Monitoring Switch Traffic 367 The packet that is copied to the destination port is in the same format as the original packet on the wire. This means that if the mirror is copying a received packet, the copied packet is VLAN tagged or untagged as it was received on the source port. If the mirror is copying a transmitted packet, the copied packet is VLAN tagged or untagged as it is being transmitted on the source port. After you configure the port mirroring session, you can enable or disable the administrative mode of the session to start or stop the probe port from receiving mirrored traffic. Why is Traffic Monitoring Needed? Monitoring the traffic that the switch handles, as well as monitoring all traffic in the network, can help provide information about network performance and utilization. This information can be useful in network planning and resource allocation. Information about traffic flows can also help troubleshoot problems in the network. Default Traffic Monitoring Values The sFlow agent is enabled by default, but sampling and polling are disabled on all ports. Additionally, no sFlow receivers (collectors) are configured. Table 15-1 contains additional default values for the sFlow feature. Table 15-1. sFlow Defaults Parameter Default Value Receiver timeout for sampling 0 Receiver port 6343 Receiver Maximum Datagram Size 1400 bytes Maximum header size 128 bytes RMON is enabled by default, but no RMON alarms, events, or history statistic groups are configured. Port mirroring is disabled, and no ports are configured as source or destination ports. After you configure a port mirroring session, the administrative mode is disabled until you explicitly enable it. 368 Monitoring Switch Traffic Monitoring Switch Traffic (Web) This section provides information about the OpenManage Switch Administrator pages to use to monitor network traffic on a PowerConnect 7000 Series switch. For details about the fields on a page, click at the top of the page. sFlow Agent Summary Use the sFlow Agent Summary page to view information about sFlow MIB and the sFlow Agent IP address. To display the Agent Summary page, click System → sFlow → Agent Summary in the navigation panel. Figure 15-2. sFlow Agent Summary Monitoring Switch Traffic 369 sFlow Receiver Configuration Use the sFlow Receiver Configuration page to configure settings for the sFlow receiver to which the switch sends sFlow datagrams. You can configure up to eight sFlow receivers that will receive datagrams. To display the Receiver Configuration page, click System → sFlow → Receiver Configuration in the navigation panel. Figure 15-3. sFlow Receiver Configuration Click Show All to view information about configured sFlow receivers. 370 Monitoring Switch Traffic sFlow Sampler Configuration Use the sFLow Sampler Configuration page to configure the sFlow sampling settings for switch ports. To display the Sampler Configuration page, click System → sFlow → Sampler Configuration in the navigation panel. Figure 15-4. sFlow Sampler Configuration Click Show All to view information about configured sampler data sources. Monitoring Switch Traffic 371 sFlow Poll Configuration Use the sFLow Poll Configuration page to configure how often a port should collect counter samples. To display the Sampler Configuration page, click System → sFlow → Sampler Configuration in the navigation panel. Figure 15-5. sFlow Poll Configuration Click Show All to view information about the ports configured to collect counter samples. 372 Monitoring Switch Traffic Interface Statistics Use the Interface Statistics page to display statistics for both received and transmitted packets. The fields for both received and transmitted packets are identical. To display the page, click Statistics/RMON → Table Views → Interface Statistics in the navigation panel. Figure 15-6. Interface Statistics Monitoring Switch Traffic 373 Etherlike Statistics Use the Etherlike Statistics page to display interface statistics. To display the page, click Statistics/RMON → Table Views → Etherlike Statistics in the navigation panel. Figure 15-7. Etherlike Statistics 374 Monitoring Switch Traffic GVRP Statistics Use the GVRP Statistics page to display switch statistics for GVRP. To display the page, click Statistics/RMON → Table Views → GVRP Statistics in the navigation panel. Figure 15-8. GVRP Statistics Monitoring Switch Traffic 375 EAP Statistics Use the EAP Statistics page to display information about EAP packets received on a specific port. For more information about EAP, see "Configuring Port and System Security" on page 481. To display the EAP Statistics page, click Statistics/RMON → Table Views → EAP Statistics in the navigation panel. Figure 15-9. EAP Statistics 376 Monitoring Switch Traffic Utilization Summary Use the Utilization Summary page to display interface utilization statistics. To display the page, click Statistics/RMON → Table Views → Utilization Summary in the navigation panel. Figure 15-10. Utilization Summary Monitoring Switch Traffic 377 Counter Summary Use the Counter Summary page to display interface utilization statistics in numeric sums as opposed to percentages. To display the page, click Statistics/RMON → Table Views → Counter Summary in the navigation panel. Figure 15-11. 378 Counter Summary Monitoring Switch Traffic Switchport Statistics Use the Switchport Statistics page to display statistical summary information about switch traffic, address tables, and VLANs. To display the page, click Statistics/RMON → Table Views → Switchport Statistics in the navigation panel. Figure 15-12. Switchport Statistics Monitoring Switch Traffic 379 RMON Statistics Use the RMON Statistics page to display details about switch use such as packet processing statistics and errors that have occurred on the switch. To display the page, click Statistics/RMON → RMON → Statistics in the navigation panel. Figure 15-13. 380 RMON Statistics Monitoring Switch Traffic RMON History Control Statistics Use the RMON History Control page to maintain a history of statistics on each port. For each interface (either a physical port or a port-channel), you can define how many buckets exist, and the time interval between each bucket snapshot. To display the page, click Statistics/RMON → RMON → History Control in the navigation panel. Figure 15-14. RMON History Control Adding a History Control Entry To add an entry: 1 Open the RMON History Control page. 2 Click Add. The Add History Entry page displays. Monitoring Switch Traffic 381 Figure 15-15. Add History Entry 3 Select the port or LAG on which you want to maintain a history of statistics. 4 Specify an owner, the number of historical buckets to keep, and the sampling interval. 5 Click Apply to add the entry to the RMON History Control Table. To view configured history entries, click the Show All tab. The RMON History Control Table displays. From this page, you can remove configured history entries. 382 Monitoring Switch Traffic RMON History Table Use the RMON History Table page to display interface-specific statistical network samplings. Each table entry represents all counter values compiled during a single sample. To display the RMON History Table page, click Statistics/RMON → RMON → History Table in the navigation panel. Figure 15-16. RMON History Table Monitoring Switch Traffic 383 RMON Event Control Use the RMON Events Control page to define RMON events. Events are used by RMON alarms to force some action when a threshold is crossed for a particular RMON counter. The event information can be stored in a log and/or sent as a trap to a trap receiver. To display the page, click Statistics/RMON → RMON → Event Control in the navigation panel. Figure 15-17. RMON Event Control Adding an RMON Event To add an event: 1 Open the RMON Event Control page. 2 Click Add. The Add an Event Entry page displays. 384 Monitoring Switch Traffic Figure 15-18. Add an Event Entry 3 If the event sends an SNMP trap, specify the SNMP community to receive the trap. 4 Optionally, provide a description of the event and the name of the event owner. 5 Select an event type. 6 Click Apply. The event is added to the RMON Event Table, and the device is updated. Viewing, Modifying, or Removing an RMON Event To manage an event: 1 Open the RMON Event Control page. 2 Click Show All to display the Event Control Table page. 3 To edit an entry: a Select the Edit check box in for the event entry to change. b Modify the fields on the page as needed. 4 To remove an entry, select the Remove check box in for the event entry to remove. 5 Click Apply. Monitoring Switch Traffic 385 RMON Event Log Use the RMON Event Log page to display a list of RMON events. To display the page, click Statistics/RMON → RMON → Events Log in the navigation panel. Figure 15-19. 386 RMON Event Log Monitoring Switch Traffic RMON Alarms Use the RMON Alarms page to set network alarms. Alarms occur when certain thresholds are crossed for the configured RMON counters. The alarm triggers an event to occur. The events can be configured as part of the RMON Events group. For more information about events, see "RMON Event Log" on page 386. To display the page, click Statistics/RMON → RMON → Alarms in the navigation panel. Figure 15-20. RMON Alarms Monitoring Switch Traffic 387 Adding an Alarm Table Entry To add an alarm: 1. Open the RMON Alarms page. 2. Click Add. The Add an Alarm Entry page displays. Figure 15-21. Add an Alarm Entry 3. Complete the fields on this page as needed. Use the help menu to learn more information about the data required for each field. 4. Click Apply. The RMON alarm is added, and the device is updated. To view configured alarm entries, click the Show All tab. The Alarms Table displays. From this page, you can remove configured alarms. 388 Monitoring Switch Traffic Port Statistics Use the Port Statistics page to chart port-related statistics on a graph. To display the page, click Statistics/RMON → Charts → Port Statistics in the navigation panel. Figure 15-22. Ports Statistics To chart port statistics, select the type of statistics to chart and (if desired) the refresh rate, then click Draw. Monitoring Switch Traffic 389 LAG Statistics Use the LAG Statistics page to chart LAG-related statistics on a graph. To display the page, click Statistics/RMON → Charts → LAG Statistics in the navigation panel. Figure 15-23. LAG Statistics To chart LAG statistics, select the type of statistics to chart and (if desired) the refresh rate, then click Draw. 390 Monitoring Switch Traffic Port Mirroring Use the Port Mirroring page to create a mirroring session in which all traffic that is sent or received (or both) on one or more source ports is mirrored to a destination port. To display the Port Mirroring page, click Switching → Ports → Traffic Mirroring → Port Mirroring in the navigation panel. Figure 15-24. Port Mirroring Configuring a Port Mirror Session To configure port mirroring: 1 Open the Port Mirroring page. 2 Click Add. The Add Source Port page displays. 3 Select the port to be mirrored. 4 Select the traffic to be mirrored. Monitoring Switch Traffic 391 Figure 15-25. Add Source Port 5 Click Apply. 6 Repeat the previous steps to add additional source ports. 7 Click Port Mirroring to return to the Port Mirroring page. 8 Enable the administrative mode and specify the destination port. Figure 15-26. Configure Additional Port Mirroring Settings 9 Click Apply. 392 Monitoring Switch Traffic Monitoring Switch Traffic (CLI) This section provides information about the commands you use to manage traffic monitoring features on the switch and to view information about switch traffic. For more information about these commands, see the PowerConnect 7000 Series CLI Reference Guide at support.dell.com/manuals. Configuring sFlow Beginning in Privileged EXEC mode, use the following commands to configure the sFlow receiver and to configure the sampling and polling on switch interfaces. Command Purpose configure Enter Global Configuration mode sflow rcvr_index destination ip-address [port] Configure the address of the sFlow receiver and (optionally) the destination UDP port for sFlow datagrams. • rcvr_index—The index of this sFlow receiver (Range: 1–8). • ip-address—The sFlow receiver IP address. • port —The destination Layer 4 UDP port for sFlow datagrams. (Range: 1–65535). sflow rcvr_index destination owner owner_string timeout timeout sflow rcvr_index maxdatagram size Specify the identity string of the receiver and set the receiver timeout value. timeout—The number of seconds the configuration will be valid before it is automatically cleared. A value of 0 essentiality means the receiver is not configured. Specify the maximum number of data bytes that can be sent in a single sample datagram. The receiver should also be set this value to avoid fragmentation of the sFlow datagrams. (Range: 200–9116 bytes). Monitoring Switch Traffic 393 Command Purpose sflow rcvr-index polling Enable a new sFlow poller instance on an interface range. if_type if_number pollinterval • rcvr-index — The sFlow Receiver associated with the poller (Range: 1–8). • if_type if_number — The list of interfaces to poll. The interface type can be Gigabitethernet (gi) or Tengigabitethernet (te), for example gi1/0/3-5 enables polling on ports 3, 4, and 5. • poll-interval — The sFlow instance polling interval. A value of n means once in n seconds a counter sample is generated. (Range: 0–86400). sflow rcvr-index sampling if_type Enable a new sflow sampler instance for the specified interface range. if_number sampling-rate • rcvr-index — The sFlow Receiver for this sFlow sampler [size] to which flow samples are to be sent. • if_type if_number — The list of interfaces to sample. The interface type can be Gigabitethernet (gi) or Tengigabitethernet (te), for example gi1/0/3-5 enables polling on ports 3, 4, and 5. • sampling-rate — The statistical sampling rate for packet sampling from this source. A sampling rate of 1 counts all packets. A value of n means that out of n incoming packets, 1 packet will be sampled. (Range: 1024 - 65536). • size — The maximum number of bytes that should be copied from the sampler packet (Range: 20 - 256 bytes). interface interface Enter interface configuration mode for the specified interface. The interface variable includes the interface type and number, for example gigabitethernet 1/0/3 or gi1/0/3. You can also specify a range of interfaces with the interface range command, for example, interface range gigabitethernet 1/0/8-12 configures interfaces 8, 9, 10, 11, and 12. sflow rcvr-index polling poll-interval Enable a new sFlow poller instance for the interface. sflow rcvr-index sampling Enable a new sflow sampler instance for the interface. sampling-rate [size] 394 Monitoring Switch Traffic Command Purpose CTRL + Z Exit to Privileged Exec mode. show sflow agent View information about the switch sFlow agent. show sflow index destination View information about a configured sFlow receivers. show sflow index polling View information about the configured sFlow poller instances for the specified receiver. show sflow index sampling View information about the configured sFlow sampler instances for the specified receiver. Configuring RMON Beginning in Privileged EXEC mode, use the following commands to configure RMON alarms, collection history, and events. The table also lists the commands you use to view information collected by the RMON probe. Command Purpose configure Enter Global Configuration mode rmon event number [log] [trap community] [description string] [owner string] Configure an RMON event. • number — The event index. (Range: 1–65535) • log — Specify that an entry is made in the log table for each event. • trap community — If the event is an SNMP trap to be sent, it is sent to the SNMP community specified by this octet string. (Range: 0-127 characters) • description string — A comment describing this event. (Range 0-127 characters) • owner string — Enter a name that specifies who configured this event. If unspecified, the name is an empty string. Monitoring Switch Traffic 395 Command Purpose rmon alarm number variable interval Add an alarm entry • number — The alarm index. (Range: 1–65535) {absolute |delta} risingthreshold value [event- • variable — A fully qualified SNMP object identifier that resolves to a particular instance of an MIB object. number] risingthreshold value [event- • interval — The interval in seconds over which the data is number] [startup sampled and compared with the rising and falling direction] [owner string] thresholds. (Range: 1–4294967295) • rising-threshold value — Rising threshold value. (Range: 0–4294967295) • rising-threshold value — Falling threshold value. (Range: 0–4294967295) • event-number — The index of the event that is used when a rising or falling threshold is crossed. (Range: 165535) • delta — The sampling method for the selected variable and calculating the value to be compared against the thresholds. If the method is delta, the selected variable value at the last sample is subtracted from the current value, and the difference compared with the thresholds. • absolute — The sampling method for the selected variable and calculating the value to be compared against the thresholds. If the method is absolute, the value of the selected variable is compared directly with the thresholds at the end of the sampling interval. • startup direction — The type of startup alarm, which can be rising, falling, or rising-falling. • owner string — Enter a name that specifies who configured this alarm. interface interface 396 Enter Interface Configuration mode for the specified port or LAG. Monitoring Switch Traffic Command Purpose rmon collection history index [owner ownername] [buckets bucket-number] [interval seconds] Enable an RMON MIB history statistics group on the interface. NOTE: You must configure RMON alarms and events before RMON collection history is able to display. • index — The requested statistics index group. (Range: 1–65535) • ownername — Records the RMON statistics group owner name. If unspecified, the name is an empty string. • bucket-number — A value associated with the number of buckets specified for the RMON collection history group of statistics. If unspecified, defaults to 50. (Range: 1 - 65535) • seconds — The number of seconds in each polling cycle. If unspecified, defaults to 1800. (Range: 1–3600) CTRL + Z Exit to Privileged EXEC mode. show rmon {alarms |collection history | events | history | log | statistics} View information collected by the RMON probe. Viewing Statistics Use the following commands in Privileged EXEC mode to view statistics about the traffic handled by the switch. Command Purpose show interfaces counters Display the number of octets and packets handled by all [if_type if_number | interfaces or the specified interface. port-channel interface] Display detailed statistics for a specific port or LAG, or for show statistics {switchport | interface} the entire switch. The interface variable includes the interface type and number. show gvrp statistics interface Displays GVRP statistics for the specified port or LAG. Monitoring Switch Traffic 397 Configuring Port Mirroring Use the following commands in Privileged EXEC mode to configure a port mirroring session. Command Purpose configure Enter Global Configuration mode monitor session Configure a source (monitored) port or CPU interface for a monitor session. session_number source interface {cpu | interface} [rx | tx] • session_number —The monitoring session ID, which is always 1. • interface—The Ethernet interface to be monitored. • rx | tx — Monitor ingress (rx) or egress (tx) traffic. If you not specify, both ingress and egress traffic is monitored. monitor session Configure a destination (probe) port for a monitor session. destination interface • session_number —The monitoring session ID, which is always 1. session_number interface • interface—The Ethernet interface to which the monitored source traffic is copied. monitor session session_number mode Enable the administrative mode for the configured port mirroring session to start sending the traffic from the source port to the destination (probe) port. exit Exit to Privileged EXEC mode. show monitor session 1 View information about the configured port mirroring session. 398 Monitoring Switch Traffic Traffic Monitoring Configuration Examples This section contains the following examples: • Configuring sFlow • Configuring RMON Configuring sFlow This example shows how to configure the switch so that ports 10-15 and port 23 send sFlow datagrams to an sFlow receiver at the IP address 192.168.20.34. The receiver owner is receiver1, and the timeout is 100000 seconds. A counter sample is generated on the ports every 60 seconds (polling interval), and 1 out of every 8192 packets is sampled. Note that sFlow monitoring is not enabled until a receiver owner string is configured. To configure the switch: 1 Configure information about the sFlow receiver. console#configure console(config)#sflow 1 destination 192.168.30.34 console(config)#sflow 1 destination owner receiver1 timeout 100000 2 Configure the polling and sampling information for gigabit Ethernet ports 10-20. console(config)#sflow 1 polling gi1/0/10-15 60 console(config)#sflow 1 sampling gi1/0/10-15 8192 3 Configure the polling and sampling information for gigabit Ethernet port 23. console(config)#interface gi1/0/23 console(config-if-Gi1/0/23)#sflow 1 polling 60 console(config-if-Gi1/0/23)#sflow 1 sampling 8192 4 Verify the configured information. console#show sflow 1 destination Receiver Index.................... Owner String...................... Time out.......................... IP Address:....................... 1 receiver1 99994 192.168.30.34 Monitoring Switch Traffic 399 Address Type...................... Port.............................. Datagram Version.................. Maximum Datagram Size............. 1 6343 5 1400 console#show sflow 1 polling Poller Data Source ----------gi1/0/10 gi1/0/11 gi1/0/12 gi1/0/13 gi1/0/14 gi1/0/15 gi1/0/23 Receiver Index ------1 1 1 1 1 1 1 Poller Interval ------60 60 60 60 60 60 60 console#show sflow 1 sampling Sampler Data Source ----------gi1/0/10 gi1/0/11 gi1/0/12 gi1/0/13 gi1/0/14 gi1/0/15 gi1/0/23 400 Receiver Index ------1 1 1 1 1 1 1 Monitoring Switch Traffic Packet Sampling Rate ------------8192 8192 8192 8192 8192 8192 8192 Max Header Size ---------128 128 128 128 128 128 128 Configuring RMON This example generates a trap and creates a log entry when the number of inbound packets are undeliverable due to errors increases by 20 or more. First, an RMON event is created. Then, the alarm is created. The event (event 1) generates a trap and creates a log entry. The alarm is configured for the MIB object ifInErrors (OID: 1.3.6.1.2.1.2.2.1.14.1). The OID is the variable. The alarm checks the variable every 30 seconds to compare the MIB counter to the configured rising and falling thresholds. If the rise is equal to or greater than 20, event 1 goes into effect. To configure the switch: 1 Create the event. The trap is sent to the private SNMP community. console#configure console(config)#rmon event 1 description "emergency event" log trap private 2 Create the alarm. console(config)#rmon alarm 1 1.3.6.1.2.1.2.2.1.14.1 30 delta rising-threshold 20 1 falling-threshold 1 3 Verify the configuration. console#show rmon events Index Description Type Community Owner Last time sent ------------------------------------------------------------1 emergency log-trap private 0 days 0h:0m:0s event console#show rmon alarms Index OID Owner ---------------------------------------------1 1.3.6.1.2.1.2.2.1.14.1 Monitoring Switch Traffic 401 402 Monitoring Switch Traffic 16 Configuring iSCSI Optimization This chapter describes how to configure Internet Small Computer System Interface (iSCSI) optimization, which enables special quality of service (QoS) treatment for iSCSI traffic. The topics covered in this chapter include: • iSCSI Optimization Overview • Default iSCSI Optimization Values • Configuring iSCSI Optimization (Web) • Configuring iSCSI Optimization (CLI) • iSCSI Optimization Configuration Examples NOTE: iSCSI optimization is supported on the PC70xx switches. iSCSI Optimization Overview iSCSI optimization provides a means of monitoring iSCSI sessions and iSCSI traffic on the switch. This is accomplished by monitoring, or “snooping,” traffic to detect packets used by iSCSI stations to establish iSCSI sessions and connections. Data from these exchanges may optionally be used to create classification rules to assign traffic between the stations to a configured traffic class. The traffic classification affects how the packets in the flow are queued and scheduled for egress on the destination port. Configuring iSCSI Optimization 403 What Does iSCSI Optimization Do? In networks containing iSCSI initiators and targets, iSCSI Optimization helps to monitor iSCSI sessions or give iSCSI traffic preferential QoS treatment. Dynamically-generated classifier rules generated by snooping iSCSI traffic are used to direct iSCSI data traffic to queues that can be given the desired preference characteristics over other data traveling through the switch. This may help to avoid session interruptions during times of congestion that would otherwise cause iSCSI packets to be dropped. However, in systems where a large proportion of traffic is iSCSI, it may also interfere with other network control-plane traffic, such as ARP or LACP. The preferential treatment of iSCSI traffic needs to be balanced against the needs of other critical data in the network. How Does the Switch Detect iSCSI Traffic Flows? The switch snoops iSCSI session establishment (target login) and termination (target logout) packets by installing classifier rules that trap iSCSI protocol packets to the CPU for examination. Devices that initiate iSCSI sessions generally use well-known TCP ports 3260 or 860 to contact targets. When iSCSI optimization is enabled, by default the switch identifies IP packets to or from these ports as iSCSI session traffic. In addition, the switch separately tracks connections associated with a login session (ISID) (dynamically allocated source/destination TCP port numbers). You can configure the switch to monitor traffic for additional port numbers or port number-target IP address combinations, and you can remove the well-known port numbers from monitoring. You can also associate a target name with a configured target TCP port entry. How Is Quality of Service Applied to iSCSI Traffic Flows? The iSCSI CoS mode is configurable and controls whether CoS queue assignment and/or packet marking is performed on iSCSI traffic. When the iSCSI CoS mode is enabled, the CoS policy is applied to packets in detected iSCSI sessions. When the iSCSI CoS mode is disabled, iSCSI sessions and connections are detected and shown in the status tables, but no CoS policy is applied to packets. When iSCSI CoS mode is enabled, iSCSI login sessions up to the switch limits are tracked, and data packets for those sessions are given the configured CoS treatment. iSCSI sessions in excess of the switch limits are not given the 404 Configuring iSCSI Optimization configured CoS treament; therefore, it is not advisable to exceed the iSCSI session limit. Multiple connections within a session are counted against the session limit, even though they show in the session table as a single session. In the switch, iSCSI connections are aged out using the session aging timer. If the connection has no detected data packets during the timeout period, the connection is deleted from the switch internal session table. When all connections associated with a session age out or disconnect, the session is deleted. You can configure whether the iSCSI optimization feature uses the VLAN priority or IP DSCP mapping to determine the traffic class queue. By default, iSCSI flows are assigned to the highest VLAN priority tag or DSCP value mapped to the highest queue not used for stack management or voice VLAN. Use the classofservice dot1p-mapping command or the Quality of Service → Class of Service → Mapping Table Configuration page to configure the relevant Class of Service parameters for the queue in order to complete the setting. You can configure whether iSCSI frames are remarked to contain the configured VLAN priority tag or IP DSCP when forwarded through the switch. How Does iSCSI Optimization Use ACLs? iSCSI Optimization borrows ACL lists from the global system pool. ACL lists allocated by iSCSI Optimization reduce the total number of ACLs available for use by the network operator. Enabling iSCSI Optimization uses one ACL list to monitor for iSCSI sessions. Each monitored iSCSI session utilizes two rules from additional ACL lists up to a maximum of two ACL lists. This means that the maximum number of ACL lists allocated by iSCSI is three. What Information Does the Switch Track in iSCSI Traffic Flows? Packets are examined to find the following data, which is used in tracking the session and creating the classifier entries that enable QoS treatment: • Initiator's IP Address • Target's IP Address • ISID (Initiator defined session identifier) • Initiator's IQN (iSCSI Qualified Name) Configuring iSCSI Optimization 405 • Target's IQN • Initiator's TCP Port • Target's TCP Port If no iSCSI traffic is detected for a session for a configurable aging period, the session data is cleared. 406 Configuring iSCSI Optimization How Does iSCSI Optimization Interact With Dell EqualLogic Arrays? The iSCSI feature includes auto-provisioning support with the ability to detect directly connected Dell EqualLogic (EQL) SAN storage arrays and automatically reconfigure the switch to enhance storage traffic flows. The PowerConnect 7000 Series switches use LLDP, a vendor-neutral protocol, to discover Dell EQL devices on the network. LLDP is enabled by default. For more information about LLDP, see "Discovering Network Devices" on page 659. When the switch detects a Dell EQL array, the following actions occur: • An MTU of 9216 is enabled on all ports and port-channels, if it is not already enabled. • Spanning-Tree portfast is enabled on the EQL-connected interface identified by LLDP. • Unicast storm control is disabled on the EQL-connected interface identified by LLDP. It is advisable to enable spanning-tree portfast and disable unicast storm control on ports connected to the initiators as well. If the iSCSI CoS policy feature is enabled on the switch and an EQL array is detected, the switch applies additional iSCSI CoS policies to the EQL interarray traffic on TCP ports 9876 and 25555. If the iSCSI CoS policy is disabled and EQL arrays are present, the additional CoS policy is removed globally. What Occurs When iSCSI Optimization Is Enabled or Disabled? When iSCSI is enabled on the switch, the following actions occur: • Flow control is globally enabled, if it is not already enabled. • iSCSI session snooping is enabled • iSCSI LLDP monitoring starts to automatically detect Dell EqualLogic arrays. If the iSCSI feature is disabled on the switch, iSCSI resources are released and the detection of Dell EqualLogic arrays by using LLDP is disabled. Disabling iSCSI does not remove the MTU, flow control, portfast or storm control configuration applied as a result of enabling iSCSI. iSCSI Optimization is enabled by default. Configuring iSCSI Optimization 407 How Does iSCSI Optimization Interact with Dell Compellent Arrays? Dell PowerConnect switches support a macro that may be used to configure a port connected to a Dell Compellent storage array. The name of the macro is profile-compellent-nas. The macro takes a single argument: the interface identifier to which the Dell Compellent array is connected. The macro disables unicast storm control and sets the spanning tree configuration on the port to portfast. For an example of how to execute the macro, see "Configuring iSCSI Optimization Between Servers and a Disk Array" on page 416. 408 Configuring iSCSI Optimization Default iSCSI Optimization Values Table 16-1 shows the default values for the iSCSI optimization feature. Table 16-1. iSCSI Optimization Defaults Parameter Default Value iSCSI Optimization Global Status Enabled iSCSI CoS mode Disabled Jumbo Frames Disabled Spanning-tree Portfast Disabled Unicast Storm Control Disabled Classification iSCSI packets are classified by VLAN instead of by DSCP values. VLAN Priority tag iSCSI flows are assigned by default the highest 802.1p VLAN priority tag mapped to the highest queue not used for stack management or the voice VLAN. DSCP When DSCP is selected as the classification, iSCSI flows are assigned by default the highest DSCP tag mapped to the highest queue not used for stack management or the voice VLAN. Remark Not enabled iSCSI Session Aging Time 10 minutes iSCSI Optimization Target Ports iSCSI well-known ports 3260 and 860 are configured as default (with no IP address or name) but can be removed as any other configured target. Configuring iSCSI Optimization 409 Configuring iSCSI Optimization (Web) This section provides information about the OpenManage Switch Administrator pages to use to the iSCSI features on a PowerConnect 7000 Series switch. For details about the fields on a page, click at the top of the page. iSCSI Global Configuration Use the Global Configuration page to allow the switch to snoop for iSCSI sessions/connections and to configure QoS treatment for packets where the iSCSI protocol is detected. To access the iSCSI Global Configuration page, click System → iSCSI → Global Configuration in the navigation panel. Figure 16-1. iSCSI Global Configuration 410 Configuring iSCSI Optimization iSCSI Targets Table Use the Targets Table page to view and configure iSCSI targets on the switch. To access the Targets Table page, click System → iSCSI → Targets in the navigation panel. Figure 16-2. iSCSI Targets Table To add an iSCSI Target, click Add at the top of the page and configure the relevant information about the iSCSI target. Figure 16-3. Add iSCSI Targets Configuring iSCSI Optimization 411 iSCSI Sessions Table Use the Sessions Table page to view summary information about the iSCSI sessions that the switch has discovered. An iSCSI session occurs when an iSCSI initiator and iSCSI target communicate over one or more TCP connections. The maximum number of iSCSI sessions is 192. Redundant (MPIO paths) may not be accounted for in the iSCSI sessions table if a separate iSCSI login is not issued during establishment of the session. To access the Sessions Table page, click System → iSCSI → Sessions Table in the navigation panel. Figure 16-4. iSCSI Sessions Table 412 Configuring iSCSI Optimization iSCSI Sessions Detailed Use the Sessions Detailed page to view detailed information about an iSCSI sessions that the switch has discovered. To access the Sessions Detailed page, click System → iSCSI → Sessions Detailed in the navigation panel. Figure 16-5. iSCSI Sessions Detail Configuring iSCSI Optimization 413 Configuring iSCSI Optimization (CLI) This section provides information about the commands you use to configure iSCSI settings on the switch. For more information about the commands, see the PowerConnect 7000 Series CLI Reference Guide at support.dell.com/manuals. Command Purpose configure Enter Global Configuration mode. iSCSI optimization is enabled by default. iscsi target port tcp-port-1 [tcp-port-2...tcp-port-16] [address ip-address] [name targetname] Configure an iSCSI target port and, optionally, address and name. • tcp-port-n—TCP port number or list of TCP port numbers on which the iSCSI target listens to requests. Up to 16 TCP ports can be defined in the system in one command or by using multiple commands. • ip-address—IP address of the iSCSI target. When the no form of this command is used, and the tcp port to be deleted is one bound to a specific IP address, the address field must be present. • targetname—iSCSI name of the iSCSI target. The name can be statically configured; however, it can be obtained from iSNS or from sendTargets response. The initiator must present both its iSCSI Initiator Name and the iSCSI Target Name to which it wishes to connect in the first login request of a new session or connection. 414 Configuring iSCSI Optimization Command Purpose iscsi cos {enable | disable | Optionally set the quality of service profile that will vtp vtp | dscp dscp [remark] be applied to iSCSI flows. • enable—Enables application of preferential QoS treatment to iSCSI frames. On switches that support DCBX, this also enables the generation of the Application Priority TLV for iSCSI. • disable—Disables application of preferential QoS treatment to iSCSI frames. • vpt/dscp—The VLAN Priority Tag or DSCP value to assign received iSCSI session packets. • remark—Mark the iSCSI frames with the configured DSCP value when egressing the switch. iscsi aging time time Optionally set aging time (range: 1–43,200 seconds) for iSCSI connections. When all connections associated with a session are aged out, the session is deleted. exit Exit to Privilege Exec mode. show iscsi Display iSCSI settings. show iscsi sessions Display iSCSI session information. Redundant (MPIO paths) may not be accounted for in the iSCSI sessions table if a separate iSCSI login is not issued during establishment of the session. Configuring iSCSI Optimization 415 iSCSI Optimization Configuration Examples iSCSI optimization is enabled by default with the appropriate settings to operate properly is almost all configurations. However, you find it necessary to alter those settings, the following procedure illustrates the configuration steps required. Configuring iSCSI Optimization Between Servers and a Disk Array Figure 16-6 illustrates a stack of three PowerConnect 7000 Series switches connecting two servers (iSCSI initiators) to a disk array (iSCSI targets). An iSCSI application running on the management unit (the top unit in the diagram) has installed priority filters to ensure that iSCSI traffic that is part of these two sessions receives priority treatment when forwarded in hardware. Figure 16-6. iSCSI Optimization 416 Configuring iSCSI Optimization The following commands show how to configure the iSCSI example depicted in Figure 16-6. Remember that iSCSI optimization is enabled by default. 1 Set the MTU to 9216 to enable the use of jumbo frames. console#config console(config)#ip mtu 9216 2 Optionally configure the switch to associate CoS queue 5 with detected iSCSI session traffic. console(config)#iscsi cos enable console(config)#exit The default target port and IP address criteria is used to determine which packets are snooped for iSCSI session data (ports 860 and 3260; any IP address). 3 If the array is a Compellent storage array, execute the Compellent macro on the ports attached to the array: console#config console(config)#macro global apply profile-compellent-nas $interface_name te1/0/21 console(config)#macro global apply profile-compellent-nas $interface_name te1/0/22 console(config)#macro global apply profile-compellent-nas $interface_name te1/0/23 Configuring iSCSI Optimization 417 418 Configuring iSCSI Optimization Configuring Captive Portal 17 This chapter describes how to configure the Captive Portal feature. The topics covered in this chapter include: • Captive Portal Overview • Default Captive Portal Behavior and Settings • Configuring the Captive Portal (Web) • Configuring Captive Portal (CLI) • Captive Portal Configuration Example Captive Portal Overview A Captive Portal helps manage or restrict network access. Captive Portals are often used in locations that provide wired Internet access to customers, such as business centers and hotels. For example, a hotel might provide an Ethernet port in each room so that guests can connect to the Internet during their stay. The hotel might charge for Internet use, or the hotel might allow guests to connect only after they indicate that they have read and agree to the acceptable use policy. What Does Captive Portal Do? The Captive Portal feature allows you to require a user to enter login information on a custom Web page before gaining access to the network. When the user connects to the port and opens a browser, the user is presented with a welcome screen. To gain network access, the user must enter a username (for guest access) or a username and password (for authenticated access) and accept the terms of use. You can also configure the Captive Portal feature to redirect the user to another web page after successful authentication, for example your company home page. Configuring Captive Portal 419 Figure 17-1. Connecting to the Captive Portal RADIUS Server (Optional) Switch with Captive Portal Captive Portal User (Host) Default Captive Portal Welcome Screen (Displays in Captive Portal User’s Browser) The Captive Portal feature blocks hosts connected to the switch from accessing the network until user verification has been established. You can configure Captive Portal verification to allow access for both guest and authenticated users. Authenticated users must be validated against a database of authorized Captive Portal users before access is granted. The database can be stored locally on the switch or on a RADIUS server. Is the Captive Portal Feature Dependent on Any Other Feature? If you require RADIUS authentication, you must configure the RADIUS server information on the switch (see "Using RADIUS Servers to Control Management Access" on page 190). You must also configure the RADIUS attributes for Captive Portal users on the RADIUS server. For information about the RADIUS attributes to configure, see Table 17-2. For a list of RADIUS attributes that the switch supports, see "Which RADIUS Attributes Does the Switch Support?" on page 192. 420 Configuring Captive Portal You can configure the switch to send SNMP trap messages to any enabled SNMP Trap Receivers for several Captive Portal events, such as when a Captive Portal user has an authentication failure or when a Captive Portal user successfully connects to the network. If you enable the traps, the switch also writes a message to the trap log when the event occurs. To enable the Captive Portal traps, see "Configuring SNMP Notifications (Traps and Informs)" on page 311. What Factors Should Be Considered When Designing and Configuring a Captive Portal? Before enabling the Captive Portal feature, decide what type (or types) of authentication to require. Since the PowerConnect 7000 Series switches support up to 10 different Captive Portal instances, you can configure one Captive Portal that requires a username and password and another that only requires the username. For each Captive Portal, you can customize the welcome screen, including the colors and logo. If you require authentication, consider the number of users that must exist in the user database. The local user database supports up to 128 users. If you need to support more than 128 authenticated users, you must use a remote RADIUS server for authentication. You can specify whether the captive portal uses HTTP or HTTPS as the protocol during the user verification process. HTTP does not use encryption during verification, and HTTPS uses the Secure Sockets Layer (SSL), which requires a certificate to provide encryption. The certificate is presented to the user at connection time. The initial Web page that a user sees when he or she connects to the Captive Portal can be customized. You can change the logo, color schemes, welcome messages, and all text on the page, including the field and button labels. The welcome page the user sees after a successful verification or authentication can also be customized. Configuring Captive Portal 421 Figure 17-2. Customized Captive Portal Welcome Screen How Does Captive Portal Work? When a port is enabled for Captive Portal, all the traffic coming onto the port from the unverified clients are dropped except for the ARP, DHCP, DNS and NETBIOS packets. These packets are allowed to be forwarded by the switch so that the unverified clients can get an IP address and are able to resolve the hostname or domain names. Data traffic from verified clients goes through as expected. If an unverified client opens a web browser and tries to connect to the network, the Captive Portal redirects all the HTTP/HTTPS traffic from the unverified clients to the authenticating server on the switch. A Captive Portal web page is sent back to the unverified client. If the verification mode for the Captive Portal associated with the port is Guest, the client can be verified without providing authentication information. If the verification mode is Local or RADIUS, the client must provide credentials that are compared against the information in the Local or RADIUS client database. After the user successfully provides the required information, the Captive Portal feature grants access to the network. 422 Configuring Captive Portal What Captive Portal Pages Can Be Customized? You can customize the following three Captive Portal pages: • Authentication Page —This page displays when a client attempts to connect to the network. You can customize the images, text, and colors that display on this page. • Logout Page — If the user logout mode is enabled, this page displays in a pop-up window after the user successfully authenticates. This window contains the logout button. • Logout Success Page — If the user logout mode is enabled, this page displays after a user clicks the logout button and successfully deauthenticates. Understanding User Logout Mode The User Logout Mode feature allows a user who successfully authenticates to the network through the captive portal to explicitly deauthenticate from the network. When User Logout Mode is disabled or the user does not specifically request logout, the connection status will remain authenticated until the Captive Portal deauthenticates the user based on the configured session timeout value. In order for the user logout feature to function properly, the client browser must have JavaScript enabled an must allow popup windows. Localizing Captive Portal Pages The Captive Portal localization feature allows you to create up to five language-specific web pages for each captive portal as long as all pages use the same verification type; either guest or authorized user web pages. This allows you to create pages in a variety of languages to accommodate a diverse group of users. To customize the pages that the user sees, click the language tab. By default, the English tab is available. The settings for the Authentication Page display. Configuring Captive Portal 423 Default Captive Portal Behavior and Settings Captive Portal is disabled by default. If you enable Captive Portal, no interfaces are associated with the default Captive Portal. After you associate an interface with the Captive Portal and globally enable the Captive Portal feature, a user who connects to the switch through that interface is presented with the Captive Portal Welcome screen shown in Figure 17-3. Figure 17-3. Default Captive Portal Welcome Screen The user types a name in the Username field, selects the Acceptance Use Policy check box, and clicks Connect to gain network access. By default, the user does not need to be defined in a database or enter a password to access the network because the default verification mode is Guest. Note that duplicate Username entries can exist in this mode because the client IP and MAC addresses are obtained for identification. Table 17-1 shows the default values for the Captive Portal feature. Table 17-1. Default Captive Portal Values Feature Value Global Captive Portal Operational Status Disabled Additional HTTP or HTTPS Ports Disabled Captive Portal can be configured to use an additional HTTP and/or HTTPS port (in support of Proxy networks). 424 Configuring Captive Portal Table 17-1. Default Captive Portal Values Feature Value Authentication Timeout 300 seconds Configured Captive Portals 1 Captive Portal Name Default Protocol Mode HTTP Verification Mode Guest URL Redirect Mode Off User Group 1-Default Session Timeout 86400 seconds Local Users None configured Interface associations None Interface status Not blocked If the Captive Portal is blocked, users cannot gain access to the network through the Captive Portal. Use this function to temporarily protect the network during unexpected events, such as denial of service attacks. Supported Captive Portal users 1024 Supported local users 128 Supported Captive Portals 10 Configuring Captive Portal 425 Configuring the Captive Portal (Web) This section provides information about the OpenManage Switch Administrator pages for configuring and monitoring Captive Portal settings on a PowerConnect 7000 Series switch. For details about the fields on a page, click at the top of the page. Captive Portal Global Configuration Use the Captive Portal Global Configuration page to control the administrative state of the Captive Portal feature and configure global settings that affect all captive portals configured on the switch. To display the Captive Portal Global Configuration page, click System → Captive Portal → Global Configuration. Figure 17-4. Captive Portal Global Configuration 426 Configuring Captive Portal Captive Portal Configuration Use the Captive Portal Configuration page to view summary information about captive portals on the system, add a captive portal, and configure existing captive portals. The switch supports 10 Captive Portal configurations. Captive Portal configuration 1 is created by default and cannot be deleted. Each captive portal configuration can have unique guest or group access modes and a customized acceptance use policy that displays when the client connects. To display the Captive Portal Configuration page, click System → Captive Portal → Configuration. Figure 17-5. Captive Portal Configuration Configuring Captive Portal 427 From the Captive Portal Configuration page, click Add to create a new Captive Portal instance. Figure 17-6. Add Captive Portal Configuration From the Captive Portal Configuration page, click Summary to view summary information about the Captive Portal instances configured on the switch. Figure 17-7. Captive Portal Summary 428 Configuring Captive Portal Customizing a Captive Portal The procedures in this section customize the pages that the user sees when he or she attempts to connect to (and log off of) a network through the captive portal. These procedures configure the English version of the Default captive portal. To configure the switch: 1 From the Captive Portal Configuration page click the (English) tab.The settings for the Authentication Page display, and the links to the Captive Portal customization appear. 2 Click Download Image to download one or more custom images to the switch. You can use a downloaded custom image for the branding logo (default: Dell logo) on the Authentication Page and Logout Success page, the account image (default: blue banner with keys) on the Authentication Page, and the background image (default: blank) on the Logout Success Page. NOTE: The image to download must be accessible from your local system. The image should be 5 KB max, 200x200 pixels, GIF or JPG format. Figure 17-8. Captive Portal Authentication Page 3 Make sure Download is selected in the Available Images menu, and click Browse. Configuring Captive Portal 429 4 Browse to the directory where the image to be downloaded is located and select the image. 5 Click Apply to download the selected file to the switch. 6 To customize the Authentication Page, which is the page that a user sees upon attempting to connect to the network, click the Authentication Page link. Figure 17-9. Captive Portal Authentication Page 430 Configuring Captive Portal 7 Select the branding image to use and customize other page components such as the font for all text the page displays, the page title, and the acceptance use policy. 8 Click Apply to save the settings to the running configuration or click Preview to view what the user will see. To return to the default views, click Clear. 9 Click the Logout Page link to configure the page that contains the logout window. NOTE: You can configure the Logout Page settings only if the User Logout Mode is selected on the Configuration page. The User Logout Mode allows an authenticated client to deauthenticate from the network. Figure 17-10. Captive Portal Logout Page 10 Customize the look and feel of the Logout Page, such as the page title and logout instructions. 11 Click Apply to save the settings to the running configuration or click Preview to view what the user will see. To return to the default views, click Clear. 12 Click the Logout Success Page link to configure the page that contains the logout window. A user is required to logout only if the User Logout Mode is selected on the Configuration page. Configuring Captive Portal 431 Figure 17-11. Captive Portal Logout Success Page 13 Customize the look and feel of the Logout Page, such as the background image and successful logout message. 14 Click Apply to save the settings to the running configuration or click Preview to view what the user will see. To return to the default views, click Clear. Local User You can configure a portal to accommodate guest users and authorized users. Guest users do not have assigned user names and passwords. Authorized users provide a valid user name and password that must first be validated against a local database or RADIUS server. Authorized users can gain network access once the switch confirms the user’s credentials. By default, each Captive Portal instance contains the default group. The default group can be renamed, or a different group can be created and assigned to each Captive Portal instance. A Captive Portal instance can be associated to one user group only. A user, however, can be assigned to multiple groups. The Local User page allows you to add authorized users to the local database, which can contain up to 128 user entries. You can also add and delete users from the local database from the Local User page. To display the Local User page, click System → Captive Portal → Local User. 432 Configuring Captive Portal Figure 17-12 shows the Local User page after a user has been added. If no users have been added to the switch, many of the fields do not display on the screen. NOTE: Multiple user groups can be selected by holding the CTRL key down while clicking the desired groups. Figure 17-12. Local User Configuration From the Local User page, click Add to add a new user to the local database. Configuring Captive Portal 433 Figure 17-13. Add Local User From the Local User page, click Show All to view summary information about the local users configured in the local database. Figure 17-14. Captive Portal Local User Summary To delete a configured user from the database, select the Remove check box associated with the user and click Apply. 434 Configuring Captive Portal Configuring Users in a Remote RADIUS Server You can use a remote RADIUS server client authorization. You must add all users to the RADIUS server. The local database does not share any information with the remote RADIUS database. Table 17-2 indicates the RADIUS attributes you use to configure authorized captive portal clients. The table indicates both RADIUS attributes and vendor-specific attributes (VSA). VSAs are denoted in the Attribute column and are comma delimited (vendor ID, attribute ID). Table 17-2. Captive Portal User RADIUS Attributes Attribute Number Description Range Usage Default User-Name 1 User name to be authorized 1-32 characters Required None User-Password 2 User password 8-64 characters Required None Session-Timeout 27 Logout once Integer session timeout is (seconds) reached (seconds). If the attribute is 0 or not present then use the value configured for the captive portal. Optional 0 Dell-CaptivePortal-Groups 6231, 127 A commaString delimited list of group names that correspond to the configured CP instance configurations. Optional None. The default group is used if not defined here Configuring Captive Portal 435 User Group You can assign Local Users to User Groups that you create. If the Verification Mode is Local or RADIUS, you assign a User Group to a Captive Portal Configuration. All users who belong to the group are permitted to access the network through this portal. The User Group list is the same for all Captive Portal configurations on the switch. To display the User Group page, click System → Captive Portal → User Group. Figure 17-15. 436 User Group Configuring Captive Portal From the User Group page, click Add to configure a new user group. Figure 17-16. Add User Group From the User Group page, click Show All to view summary information about the user groups configured on the switch. Figure 17-17. Captive Portal User Group Summary To delete a configured group, select the Remove check box associated with the group and click Apply. Configuring Captive Portal 437 Interface Association From the Interface Association page, you can associate a configured captive portal with specific interfaces. The captive portal feature only runs on the interfaces that you specify. A captive portal can have multiple interfaces associated with it, but an interface can be associated to only one Captive Portal at a time. To display the Interface Association page, click System → Captive Portal → Interface Association. Figure 17-18. Captive Portal Interface Association NOTE: When you associate an interface with a Captive Portal, the interface is disabled in the Interface List. Each interface can be associated with only one Captive Portal at a time. 438 Configuring Captive Portal Captive Portal Global Status The Captive Portal Global Status page contains a variety of information about the Captive Portal feature. From the Captive Portal Global Status page, you can access information about the Captive Portal activity and interfaces. To display the Global Status page, click System → Captive Portal → Status → Global Status. Figure 17-19. Captive Portal Global Status Configuring Captive Portal 439 Captive Portal Activation and Activity Status The Captive Portal Activation and Activity Status page provides information about each Captive Portal configured on the switch. The Captive Portal Activation and Activity Status page has a drop-down menu that contains all captive portals configured on the switch. When you select a captive portal, the activation and activity status for that portal displays. To display the Activation and Activity Status page, click System → Captive Portal → Status → Activation and Activity Status. Figure 17-20. Captive Portal Activation and Activity Status NOTE: Use the Block and Unblock buttons to control the blocked status. If the Captive Portal is blocked, users cannot gain access to the network through the Captive Portal. Use this function to temporarily protect the network during unexpected events, such as denial of service attacks. 440 Configuring Captive Portal Interface Activation Status The Interface Activation Status page shows information for every interface assigned to a captive portal instance. To display the Interface Activation Status page, click System → Captive Portal → Interface Status → Interface Activation Status. Figure 17-21. Interface Activation Status Configuring Captive Portal 441 Interface Capability Status The Interface Capability Status page contains information about interfaces that can have CPs associated with them. The page also contains status information for various capabilities. Specifically, this page indicates what services are provided through the Captive Portal to clients connected on this interface. The list of services is determined by the interface capabilities. To display the Interface Capability Status page, click System → Captive Portal → Interface Status → Interface Capability Status. Figure 17-22. 442 Interface Capability Status Configuring Captive Portal Client Summary Use the Client Summary page to view summary information about all authenticated clients that are connected through the captive portal. From this page, you can manually force the captive portal to disconnect one or more authenticated clients. The list of clients is sorted by client MAC address. To display the Client Summary page, click System → Captive Portal → Client Connection Status → Client Summary. Figure 17-23. Client Summary To force the captive portal to disconnect an authenticated client, select the Remove check box next to the client MAC address and click Apply. To disconnect all clients from all captive portals, click Delete All. Configuring Captive Portal 443 Client Detail The Client Detail page shows detailed information about each client connected to the network through a captive portal. To display the Client Detail page, click System → Captive Portal → Client Connection Status → Client Detail. Figure 17-24. 444 Client Detail Configuring Captive Portal Captive Portal Interface Client Status Use the Interface Client Status page to view clients that are authenticated to a specific interface. To display the Interface Client Status page, click System → Captive Portal → Client Connection Status → Interface Client Status. Figure 17-25. Interface - Client Status Configuring Captive Portal 445 Captive Portal Client Status Use the Client Status page to view clients that are authenticated to a specific Captive Portal configuration. To display the Client Status page, click System → Captive Portal → Client Connection Status → Client Status. Figure 17-26. 446 Captive Portal - Client Status Configuring Captive Portal Configuring Captive Portal (CLI) This section provides information about the commands you use to create and configure Captive Portal settings. For more information about the commands, see the PowerConnect 7000 Series CLI Reference Guide at support.dell.com/manuals. Configuring Global Captive Portal Settings Beginning in Privileged EXEC mode, use the following commands to configure global Captive Portal settings. Command Purpose configure Enter global configuration mode. captive-portal Enter Captive Portal mode. http port port-num (Optional) Configure an additional HTTP port for Captive Portal to monitor. Use this command on networks that use an HTTP proxy server. port-num — The port number to monitor (Range: 1–65535, excluding ports 80, 443, and the configured switch management port). https port port-num (Optional) Configure an additional HTTPS port for Captive Portal to monitor. Use this command on networks that use an HTTPS proxy server. port-num — The port number to monitor Range: 1–65535, excluding ports 80, 443, and the configured switch management port). authentication timeout timeout (Optional) Configure the number of seconds the user has to enter valid credentials into the verification page. If the user exceeds the configured timeout, the verification page needs to be served again in order for the client to gain access to the network. timeout — The authentication timeout (Range: 60–600 seconds). enable Globally enable the Captive Portal feature. Configuring Captive Portal 447 Command Purpose CTRL + Z Exit to Privileged EXEC mode. show captive-portal [status] View the Captive Portal administrative and operational status. Use the status keyword to view additional global Captive Portal information and summary information about all configured Captive Portal instances. Creating and Configuring a Captive Portal Beginning in Privileged EXEC mode, use the following commands to create a Captive Portal instance and configure its settings. Command Purpose configure Enter global configuration mode. captive-portal Enter Captive Portal mode. configuration cp-id Enter the captive portal instance mode cp-id — The Captive Portal instance (Range: 1–10). The Captive Portal configuration identified by CP ID 1 is the default CP configuration. name string Add a name to the Captive Portal instance. string — CP configuration name (Range: 1–32 characters). protocol {http | https} Specify whether to use HTTP or HTTPs during the Captive Portal user verification process. verification {guest | local | radius} Specify how to process user credentials the user enters on the verification page. • guest — Allows access for unauthenticated users (users that do not have assigned user names and passwords). • local — Authenticates users against a local user database. • radius — Authenticates users against a remote RADIUS database. radius-auth-server name Specify the name of the RADIUS server to use for RADIUS verification. Use the commands described in "Using RADIUS Servers to Control Management Access" on page 190 to configure RADIUS server settings for the switch. 448 Configuring Captive Portal Command Purpose user-logout (Optional) Enable user logout mode to allow an authenticated client to deauthenticate from the network. If this option is clear or the user does not specifically request logout, the client connection status remains authenticated until the CP deauthenticates the user, for example by reaching the idle timeout or session timeout values. redirect (Optional) Enable the redirect mode for a Captive Portal configuration so that the user is redirected to a specific Web page after the verification or authentication process. When the redirect mode is not enabled, the user sees the Captive Portal welcome page after the verification or authentication process. redirect-url url (Optional) Specify the web page that the users sees after successful verification or authentication through the Captive Portal. url — The URL for redirection (Range: 1–512 characters). group group-number (For Local and RADIUS verification) Configure the group number associated with this Captive Portal configuration. By default, only the default group exists. To assign a different user group to the Captive Portal instance, you must first configure the group. group-number — The number of the group to associate with this configuration (Range: 1–10) session-timeout timeout (Optional) Enter the number of seconds to wait before terminating a session. A user is logged out once the session timeout is reached. You can also set the session timeout for each user if the Captive Portal requires authentication. timeout — Session timeout. 0 indicates timeout not enforced (Range: 0–86400 seconds) interface interface Associate an interface with this Captive Portal. ( The interface variable includes the interface type and number, for example gigabitethernet 1/0/3. enable Enable the Captive Portal instance. Configuring Captive Portal 449 Command Purpose block (Optional) Block all traffic for a Captive Portal configuration. If the Captive Portal is blocked, users cannot gain access to the network through the Captive Portal. Use this function to temporarily protect the network during unexpected events, such as denial of service attacks. CTRL + Z Exit to Privileged EXEC mode. show captive-portal configuration cp-id [status | interface] View summary information about a Captive Portal instance. • cp-id — The Captive Portal instance (Range: 1–10). • status — View additional information about the Captive Portal instance. • interface — View information about the interface(s) associated with the specified Captive Portal. show captive-portal interface configuration cp-id status View information about the interfaces associated with the specified Captive Portal instance. cp-id — The Captive Portal instance (Range: 1–10). NOTE: To return the default Captive Portal instance to its default values, use the clear command in the Captive Portal Instance mode. You must also use the no interface interface command to remove any associated interfaces from the instance. 450 Configuring Captive Portal Configuring Captive Portal Groups and Users Beginning in Privileged EXEC mode, use the following commands to create a Captive Portal group. You can use the default group, or you can create a new group. Command Purpose configure Enter global configuration mode. captive-portal Enter Captive Portal mode. user group group-id [name name] Configure a group. Each Captive Portal that requires authentication has a group associated with it. Only the users who are members of that group can be authenticated if they connect to the Captive Portal. • group-id — Group ID (Range: 1–10). • name — Group name (Range: 1–32 characters). user user-id name name Create a new user for the local user authentication database. • user-id —User ID (Range: 1–128). • name —user name (Range: 1–32 characters). user user-id password Configure the password for the specified user. • user-id —User ID (Range: 1–128). • password —User password (Range: 8–64 characters). password user user-id group group- Associate a group with a Captive Portal user. A user can be associated with more than one group. • user-id — User ID (Range: 1–128). • group-id — Group ID (Range: 1–10). id user user-id sessiontimeout timeout Enter the number of seconds to wait before terminating a session for the specified user. The user is logged out once the session timeout is reached. • user-id — User ID (Range: 1–128). • timeout — Session timeout. 0 indicates timeout not enforced (Range: 0–86400 seconds) Configuring Captive Portal 451 Command Purpose user group group-id (Optional) Move all of the users in a group to a different moveusers new-group-id group. This command removes the users from the group specified by group-id. • group-id — Group ID (Range: 1–10). • new-group-id — Group ID (Range: 1–10). CTRL + Z Exit to Privileged EXEC mode. show captive-portal user View summary information about all users configured in [user-id] the local database. Specify the user ID to view additional information about a user. user-id — User ID (Range: 1–128). clear captive portal users (Optional) Delete all captive portal user entries from the local database. Managing Captive Portal Clients The commands in this section are all executed in Privileged EXEC mode. Use the following commands to view and manage clients that are connected to a Captive Portal. Command Purpose show captive-portal configuration [cp-id] client status Display information about the clients authenticated to all Captive Portal configurations or a to specific configuration. cp-id — The Captive Portal instance (Range: 1–10). Display information about clients authenticated on all show captive-portal interface interface client interfaces or no a specific interface. status interface — Specific Ethernet interface, such as gi1/0/8. show captive-portal client [macaddr] status Display client connection details or a connection summary for connected Captive Portal users. macaddr — The MAC address of the client. captive-portal client Deauthenticate a specific captive portal client. deauthenticate macaddr macaddr — The MAC address of the client. 452 Configuring Captive Portal Captive Portal Configuration Example The manager of a resort and conference center needs to provide wired Internet access to each guest room at the resort and in each conference room. Due to legal reasons, visitors and guests must agree to the resort’s acceptable use policy to gain network access. Additionally, network access from the conference rooms must be authenticated. The person who rents the conference room space receives a list username and password combinations upon arrival. Hotel employees have their own Captive Portal. The network administrator for the resort and conference center decides to configure the three Captive Portals Table 17-3 describes. Table 17-3. Captive Portal Instances Captive Portal Name Description Guest Free Internet access is provided in each guest room, but guests must enter a name and agree to the acceptable use policy before they can gain access. The manager wants guests to be redirected to the resort’s home web page upon successful verification. No logout is required. Conference Because physical access to the conference rooms is less secure than access to each guest room, the manager wants to ensure that people who connect to the network through a port in a conference room are authenticated. The Conference Captive Portal uses the local database for authentication. Employee To gain network access, resort employees must enter a username and password that is stored on a RADIUS server. Configuring Captive Portal 453 Configuration Overview The following steps provide an overview of the process you use to configure the Captive Portal feature. To configure the switch: 1. If you plan to use a RADIUS server for authentication, configure the RADIUS server settings on the switch. 2. If authentication is required, configure the user groups to associate with each Captive Portal. 3. Create (add) the Captive Portals. 4. Configure the Captive Portal settings for each Captive Portal, such as the verification mode. 5. Associate interfaces with the Captive Portal instances. 6. Download the branding images, such as the company logo, to the switch. The images you download must be accessible from the switch, either on the system you use to manage the switch or on a server that is on the same network as the switch. NOTE: You must use the web interface to download images. 7. Customize the authentication, logout, and logout success web pages that a Captive Portal user will see. Dell recommends that you use Use Dell OpenManage Administrator to customize the Captive Portal authentication, logout, and logout success pages. A Preview button is available to allow you to see the pages that a Captive Portal user will see. 8. If you use the local database for user authentication, configure the users on the switch. 9. If you use a RADIUS server for authentication, add the users to the database on the RADIUS server. 10. Associate interfaces with the Captive Portal instances. 11. Globally enable Captive Portal. 454 Configuring Captive Portal Detailed Configuration Procedures Use the following steps to perform the Captive Portal configuration: 1. Configure the RADIUS server information on the switch. In this example, the RADIUS server IP address is 192.168.2.188, and the RADIUS server name is luxury-radius. console#configure console(config)#radius-server host 192.168.12.182 console(Config-auth-radius)#name luxury-radius console(Config-auth-radius)#exit 2. Configure the Captive Portal groups. console(config)#captive-portal console(config-CP)#user group 2 name Conference console(config-CP)#user group 3 name Employee console(config-CP)#exit 3. Configure the Guest Captive Portal. console(config)#captive-portal console(config-CP)#configuration 2 console(config-CP 2)#name Guest console(config-CP 2)#redirect console(config-CP 2)#redirect-url http://www.luxuryresorturl.com console(config-CP 2)#interface gi1/0/1 console(config-CP 2)#interface gi1/0/2 ... console(config-CP 2)#interface gi1/0/4 console(config-CP 2)#exit 4. Configure the Conference Captive Portal. console(config-CP)#configuration 3 console(config-CP 3)#name Conference console(config-CP 3)#verification local console(config-CP 3)#group 2 console(config-CP 4)#interface gi1/0/25 ... console(config-CP 4)#interface gi1/0/33 console(config-CP 3)#exit Configuring Captive Portal 455 5. Configure the Employee Captive Portal. console(config-CP)#configuration 4 console(config-CP 4)#name Employee console(config-CP 4)#verification radius console(config-CP 4)#group 3 console(config-CP 4)#interface gi1/0/34 ... console(config-CP 4)#interface gi1/0/40 console(config-CP 4)#exit 6. Use the web interface to customize the Captive Portal pages that are presented to users when they attempt to connect to the network. NOTE: Captive Portal page customization is supported only through the Web interface. For information about customizing the Captive Portal pages, see "Customizing a Captive Portal" on page 429. 7. Add the Conference users to the local database. console(config-CP)#user 1 name EaglesNest1 console(config-CP)#user 1 password Enter password (8 to 64 characters): ********* Re-enter password: ********* console(config-CP)#user 1 group 2 Continue entering username and password combinations to populate the local database. 8. Add the User-Name, User-Password, Session-Timeout, and Dell-CaptivePortal-Groups attributes for each employee to the database on the RADIUS server. 9. Globally enable the Captive Portal. console(config-CP)#enable 456 Configuring Captive Portal 18 Configuring Port Characteristics This chapter describes how to configure physical switch port characteristics, including settings such as administrative status and Green Ethernet settings. This chapter also describes the link dependency feature. The topics covered in this chapter include: • Port Overview • Default Port Values • Configuring Port Characteristics (Web) • Configuring Port Characteristics (CLI) • Port Configuration Examples Port Overview A port is a physical interface. Cables physically connect ports on devices such as PCs or servers to ports on the switch to provide access to the network. The number and type of physical ports available on your PowerConnect 7000 Series switch depends on the model. What Physical Port Characteristics Can Be Configured? Table 18-1 provides a summary of the physical characteristics that can be configured on the switch ports. Table 18-1. Port Characteristics Feature Description Administrative status Controls whether the port is administratively enabled or disabled. Description Provides a text-based description of the port. Auto negotiation Enables a port to advertise its transmission rate, duplex mode and flow control abilities to its partner. Configuring Port Characteristics 457 Table 18-1. Port Characteristics Feature Description Speed Specifies the transmission rate for frames. Duplex mode Specifies whether the interface supports transmission between the switch and the connected client in one direction at a time (half) or both directions simultaneously (both). Maximum frame size Indicates the maximum frame size that can be handled by the port. Green Ethernet features Green Ethernet features include: • Energy detect mode • Energy Efficient Ethernet (EEE), which enables the low-power idle mode Flow control This is a global setting that affects all ports. For more information about this feature, see "Configuring Port-Based Traffic Control" on page 687. Storm control For more information about this feature, see "Configuring Port-Based Traffic Control" on page 687. Port security For more information about this feature, see "Configuring Port and System Security" on page 481. Protected port For more information about this feature, see "Configuring Port-Based Traffic Control" on page 687. What is Link Dependency? The link dependency feature provides the ability to enable or disable one or more ports based on the link state of one or more different ports. With link dependency enabled on a port, the link state of that port is dependent on the link state of another port. For example, if port A is dependent on port B and the switch detects a link loss on port B, the switch automatically brings down the link on port A. When the link is restored to port B, the switch automatically restores the link to port A. 458 Configuring Port Characteristics You can create a maximum of 72 dependency groups16 groups. The ports participating in the Link Dependency can be across all the Stack Units (Manager/Member unit). Link Action The link action specifies the action that the group members will take when the dependent port is down. The group members can transition to the same state as the dependant port, or they can transition to the opposite state. In other words, if the link action is down and the dependent port goes down, the members ports will go down as well. Conversely, when the link action is up and the dependant link goes down, the group member ports are enabled (brought up). Creating a link dependency group with the up link action essentially creates a backup link for the dependent link and alleviates the need to implement STP to handle the fail-over. Link Dependency Scenarios The Link Dependency feature supports the scenarios in the following list. NOTE: Whether the member ports or LAGs are brought up or down depends on the link action. • Port dependent on port — If a port loses the link, the switch brings up/down the link on another port. • Port dependent on LAG — If all ports in a channel-group lose the link, the switch brings up/down the link on another port. • LAG dependent on port — If a port loses the link, the switch brings up/down all links in a channel-group. • Multiple port command — If a group of ports lose their link, the switch brings up/down the link on another group of ports. • Overlapping ports — Overlapping ports on different groups will be brought up/down only if both dependent ports lose the link. Configuring Port Characteristics 459 What Interface Types are Supported? The physical ports on the switch front panel include the out-of-band (OOB) interface and Gigabit Ethernet switch ports. The OOB interface supports a limited set of features and is for switch management only. The Ethernet switch ports support many logical features that are often supported by logical interfaces. The switch supports the following types of logical interfaces: • Port-based VLANs — For more information, see "Configuring VLANs" on page 561. • VLAN routing interfaces — For more information, see "Configuring Routing Interfaces" on page 843. • Link Aggregation Groups (LAGs), which are also called port channels) — For more information, see "Configuring Link Aggregation" on page 819. • Tunnels — For more information, see "Configuring Routing Interfaces" on page 843. • Loopback interfaces — For more information, see "Configuring Routing Interfaces" on page 843. The PowerConnect 7000 Series includes two Power over Ethernet (PoE) Plus models: the PowerConnect 7024P and the PowerConnect 7048P. For information about configuring PoE plus features for the ports, see "Managing General System Settings" on page 239. Two expansion slots are located on the back of the switch and can support the following modules: • 10GBase module • SFP+ module • Stacking/10 GbE module Each plug-in module has two ports. The Stacking/10GbE modules can be configured to operate as either 16-Gigabit stacking ports or 10-Gigabit Ethernet switch ports. What is Interface Configuration Mode? When you use the CLI to configure physical or logical characteristics for an interface, you must enter Interface Configuration Mode for that interface. To enter the mode, type the keyword interface followed by the interface type and additional information to identify the interface, such as the interface number. 460 Configuring Port Characteristics To enter Interface Configuration mode for a physical switch port, the following information is required: • Type — For physical switch ports, the type is Gigabit Ethernet (gigabitethernet or gi) for 10/100/1000 Mbps Ethernet ports or 10-Gibabit Ethernet (tengigabitethernet or te) for 10,000 Mbps Ethernet ports. • Stack member number— The unit number within the stack. The range is 1–12. The default unit number for a switch that has not been in a stack is 1. To view the member number assigned to each switch in a stack, use the show switch command. • Module (slot) number—The expansion module slot. The number is 1 for a module inserted in the left slot or 2 when it is in the right slot (when viewing the back panel of the switch). For front-panel ports, the slot number is 0. • Port number—The number assigned to the port. For front-panel ports the port number is written above or below each port. Odd-numbered ports are on the top row, and even-numbered ports are on the bottom row. The port numbers increase from left to right. For ports on the optional modules, the left port is 1, and the right port is 2. For example, to enter Interface Configuration mode for Gigabit Ethernet port 10 on a switch that is not part of a stack, use the following command: console(config)#interface gigabitEthernet 1/0/10 NOTE: When you enter Interface Configuration mode, the command prompt changes and identifies the interface. In the previous example, the command prompt becomes console(config-if-Gi1/0/10)#. To enter Interface Configuration mode for Gigabit Ethernet port 6 on stack member 3, use the following command: console(config)#interface gigabitEthernet 3/0/6 To enter Interface Configuration mode for port 1 on a 10-Gigabit Ethernet module in the left slot (or top slot for the PC7048R and PC7048R-RA), use the following command: console(config)#interface tengigabitEthernet 1/1/1 For many features, you can configure a range of interfaces. When you enter Interface Configuration mode for multiple interfaces, the commands you execute apply to all interfaces specified in the range. Configuring Port Characteristics 461 To enter Interface Configuration mode for a range of interfaces, include the keyword range and specify the interfaces to configure. For example, to apply the same configuration to ports 1-10 on a standalone switch, use the following command: console(config)#interface range gigabitEthernet 1/0/1-10 To enter Interface Configuration mode for ports 3, 4, 5, 12, and 14 on a standalone switch, use the following command: console(config)#interface range gigabitEthernet 1/0/3-5,1/0/12,1/0/14 NOTE: You can switch to another interface or range of interfaces by entering the interface command while in Interface Configuration mode. It is not necessary to exit Interface Configuration mode to select a different interface. What Are the Green Ethernet Features? The Green Ethernet feature supports two per-port power-saving modes: • Energy-detect Mode • EEE All integrated 1G and module-based 10G copper ports on PowerConnect 7000 Series switches are capable of utilizing the Energy Detect and EEE modes for reduced power consumption. When the Energy Detect mode is enabled and the port link is down, the PHY automatically goes down for short period of time and then wakes up to check link pulses. This mode reduces power consumption on the port when no link partner is present. EEE enables ports to enter a low-power mode to reduce power consumption during periods of low link utilization. EEE is defined by IEEE 802.3az. EEE enables both the send and receive sides of the link to disable some functionality for power savings when the link is lightly loaded. NOTE: Cable diagnostics may give misleading results if green mode is enabled on the port. Disable green mode prior to running any cable diagnostics. 462 Configuring Port Characteristics Default Port Values Table 18-2 lists the default values for the port characteristics that this chapter describes. Table 18-2. Default Port Values Feature Description Administrative status All ports are enabled Description None defined Auto negotiation Enabled Speed Autonegotiate Duplex mode Autonegotiate Flow control Enabled Maximum frame size 1518 Energy Detect mode Disabled EEE mode Disabled Link Dependency None configured Configuring Port Characteristics 463 Configuring Port Characteristics (Web) This section provides information about the OpenManage Switch Administrator pages for configuring and monitoring port characteristics on a PowerConnect 7000 Series switch. For details about the fields on a page, click at the top of the page. Port Configuration Use the Port Configuration page to define port parameters. To display the Port Configuration page, click Switching → Ports → Port Configuration in the navigation panel. Figure 18-1. Port Configuration 464 Configuring Port Characteristics Configuring Multiple Ports To configure port settings on multiple ports: 1 Open the Port Configuration page. 2 Click Show All to display the Port Configuration Table page. 3 In the Ports list, select the check box in the Edit column for the port to configure. 4 Select the desired settings. 5 Click Apply. Figure 18-2. Configure Port Settings 6 Select the Copy Parameters From check box, and select the port with the settings to apply to other ports. 7 In the Ports list, select the check box(es) in the Copy To column that will have the same settings as the port selected in the Copy Parameters From field. Configuring Port Characteristics 465 In the following example, Ports 3, 4, and 5 will be updated with the settings that are applied to Port 1. Figure 18-3. Copy Port Settings 8 Click Apply. 466 Configuring Port Characteristics Link Dependency Configuration Use the Link Dependency Configuration page to create link dependency groups. You can create a maximum of 16 dependency groups. The page displays the groups whether they have been configured or not. To display the Link Dependency Configuration page, click Switching → Link Dependency → Configuration in the navigation panel. Figure 18-4. Link Dependency Configuration Creating a Link Dependency Group To create link dependencies: 1 Open the Link Dependency Configuration page. 2 In the Group ID field, select the ID of the group to configure. 3 Specify the link action. 4 To add a port to the Member Ports column, click the port in the Available Ports column, and then click the < button to the left of the Available Ports column. Ctrl + click to select multiple ports. Configuring Port Characteristics 467 5 To add a port to the Ports Depended On column, click the port in the Available Ports column, and then click the > button to the right of the Available Ports column. In the following example, Group 1 is configured so that Port 3 is dependent on Port 4. Figure 18-5. Link Dependency Group Configuration 6 Click Apply. The Link Dependency settings for the group are modified, and the device is updated. 468 Configuring Port Characteristics Link Dependency Summary Use the Link Dependency Summary page to view all link dependencies on the system and to access the Link Dependency Configuration page. You can create a maximum of 16 dependency groups. The page displays the groups whether they have been configured or not. To display the Link Dependency Summary page, click Switching → Link Dependency → Link Dependency Summary in the navigation panel. Figure 18-6. Link Dependency Summary To configure a group, click the Modify link associated with the ID of the group to configure. Clicking the Modify link takes you to the Link Dependency Configuration page. The Group ID is automatically selected based on the link that was clicked. Configuring Port Characteristics 469 Port Green Ethernet Configuration Use the Green Ethernet Configuration page to enable or disable energysaving modes on each port. To display the Green Ethernet Configuration page, click System → Green Ethernet → Green Ethernet Configuration in the navigation panel. Figure 18-7. Green Ethernet Configuration 470 Configuring Port Characteristics Port Green Ethernet Statistics Use the Green Ethernet Statistics page to view information about per-port energy savings. To display the Green Ethernet Statistics page, click System → Green Ethernet → Green Ethernet Statistics in the navigation panel. Figure 18-8. Green Ethernet Statistics Configuring Port Characteristics 471 To view a summary of energy savings for the switch and all ports, click Summary. Figure 18-9. Green Ethernet Statistics Summary 472 Configuring Port Characteristics To view a chart that shows the estimated per-port energy savings, click Chart. Figure 18-10. Green Ethernet Statistics Chart Configuring Port Characteristics 473 Port Green Ethernet LPI History Use the Green Ethernet LPI History page to view data about the amount of time the switch has spent in low-power idle (LPI) mode. To display the Green Ethernet LPI History page, click System → Green Ethernet → Green Ethernet LPI History in the navigation panel. Figure 18-11. 474 Green Ethernet LPI History Configuring Port Characteristics Configuring Port Characteristics (CLI) This section provides information about the commands you use to configure port characteristics. For more information about the commands, see the PowerConnect 7000 Series CLI Reference Guide at support.dell.com/manuals. Configuring Port Settings Beginning in Privileged EXEC mode, use the following commands to configure various port settings. Command Purpose configure Enter Global Configuration mode. interface interface Enter interface configuration mode for the specified interface. The interface variable includes the interface type and number, for example gigabitethernet 1/0/3. You can also specify a range of interfaces with the interface range command, for example, interface range gigabitethernet 1/0/8-12 configures interfaces 8, 9, 10, 11, and 12. description string Add a description to the port. The text string can be from1-64 characters. shutdown Administratively disable the interface. speed {10 Configure the speed of a given Ethernet interface or allow |100|1000|10000 | auto the interface to automatically detect the speed. [100|1000|10000]} If you use the 10, 100, or 1000 keywords with the auto keyword, the port auto negotiates only at the specified speeds. On combo ports, it is possible to configure auto negotiation even if only the fiber interface is active. The auto negotiation settings will be utilized when the copper port is active. Auto negotiation settings are ignored for the fiber ports. Configuring Port Characteristics 475 Command Purpose duplex {half | full | auto} Configure the full/half duplex operation of a given Ethernet interface, or enable duplex auto negotiation. Fiber ports must always be configured full-duplex. auto negotiation is never used on fiber ports. mtu size Enable jumbo frames on an interface by adjusting the maximum size of a packet. CTRL + Z Exit to Privileged EXEC mode. show interfaces status Show summary information about all interfaces. show interfaces configuration View a summary of the configuration for all ports. show interfaces advertise View a summary of the speeds that are advertised on each port. show interfaces description View configured descriptions for all ports. show interfaces detail View detailed information about the specified port. interface Configuring Link Dependencies Beginning in Privileged EXEC mode, use the following commands to configure ports that are dependent on the state of other ports. Command Purpose configure Enter Global Configuration mode. group_id link-dependency group Enter the link-dependency mode to configure a linkdependency group. add interface Add member ports to the group. The interface variable includes the interface type and number, for example gigabitethernet 1/0/3. You can also add port channels (LAGs) as members by using the keyword port-channel followed by an ID. You can also specify a range of interfaces. For example, interface gigabitethernet 1/0/8-10,1/0/20 configures interfaces 8, 9, 10 and 20. 476 Configuring Port Characteristics Command Purpose depends-on interface Specify the port(s) upon which the member ports are dependent. For information about the interface variable, see the previous command description. action {down|up} Specifies the action the member ports take when the dependent link goes down. • down—When the dependent link is down, the group members are down (the members are up otherwise). • up—When the dependent link goes down, the group members are brought up (the members are down otherwise) CTRL + Z Exit to Privileged EXEC mode. show link-dependency [group group_id] View link dependency settings for all groups or for the specified group, along with the group state. Configuring Green Features Beginning in Privileged EXEC mode, use the following commands to configure and monitor energy-saving features for the ports and the switch. Command Purpose configure Enter Global Configuration mode. interface interface Enter interface configuration mode for the specified interface. The interface variable includes the interface type and number, for example gigabitethernet 1/0/3. You can also specify a range of interfaces with the interface range command, for example, interface range gigabitethernet 1/0/8-12 configures interfaces 8, 9, 10, 11, and 12. green-mode energydetect Enable low-power idle mode on the interface. green-mode eee Enable EEE low power idle mode on the interface. exit Exit to global configuration mode. Configuring Port Characteristics 477 Command Purpose green-mode eee-lpihistory {samplinginterval seconds | maxsamples max} Configure the global EEE LPI history collection interval and buffer size. exit Exit to Privileged EXEC mode. show green-mode View green mode settings for the specified port. show green-mode eeelpi-history interface View the EEE LPI history statistics for the specified port. interface interface 478 Configuring Port Characteristics Port Configuration Examples This section contains the following examples: • Configuring Port Settings • Configuring a Link Dependency Groups Configuring Port Settings The commands in this example specify the speed and duplex mode for port 1 (gigabitethernet 1/0/1) and change the MTU size for ports 10, 11, 12, 20, and 25. To configure the switch: 1 Enter Interface Configuration mode for port 1. console#configure console(config)#interface gigabitEthernet 1/0/1 2 Change the speed and duplex settings for the port. console(config-if-Gi1/0/1)#speed 100 console(config-if-Gi1/0/1)#duplex full console(config-if-Gi1/0/1)#exit 3 Enter Interface Configuration mode for ports 10, 11, 12, 20, and 24. console(config)#interface range gigabitEthernet 1/0/10-12,1/0/20,1/0/24 4 Enable jumbo frame support on the interfaces. console(config-if)#mtu 9216 console(config-if)#CTRL + Z 5 View summary information about the ports console#show interfaces configuration Port --------Gi1/0/1 Gi1/0/2 Gi1/0/3 Gi1/0/4 Gi1/0/5 Type ------------Gigabit - Level Gigabit - Level Gigabit - Level Gigabit - Level Gigabit - Level Duplex Speed Neg Admin St. ------ ------- ---- ----Full 100 Off Up N/A Unknown Auto Up N/A Unknown Auto Up N/A Unknown Auto Up N/A Unknown Auto Up --More-- or (q)uit Configuring Port Characteristics 479 Configuring a Link Dependency Groups The commands in this example create two link dependency groups. Group 1 has port 3 as a member port that is dependent on port 4. The group uses the default link action, which is down. This means that if port 4 goes down, port 3 goes down. When port 4 returns to the up state, port 3 is brought back up. In Group 2, port 6 dependent on port-channel (LAG) 1, and the link action is up. If port-channel 1 goes down, port 6 is brought up. This also means that when port-channel 1 is up, port 6 is down. To configure the switch: 1 Enter the configuration mode for Group 1. console#configure console(config)#link-dependency group 1 2 Configure the member and dependency information for the group. console(config-linkDep-group-1)#add gigabitethernet 1/0/3 console(config-linkDep-group-1)#depends-on gigabitethernet 1/0/4 console(config-linkDep-group-1)#exit 3 Enter the configuration mode for Group 2 console(config)#link-dependency group 2 console(config-linkDep-group-2)#add gigabitethernet 1/0/6 console(config-linkDep-group-2)#depends-on portchannel 1 console(config-linkDep-group-2)#action up console(config-linkDep-group-2)#CTRL + Z 4 View the configured link dependency groups. console#show link-dependency GroupId ------1 2 480 Member Ports ------------Gi1/0/3 Gi/0/6 Ports Depended On ----------------Gi/0/4 ch1 Configuring Port Characteristics Link Action ---------Link Down Link Up Configuring Port and System Security 19 This chapter describes how to configure port-based security features, which control access to the network through the switch ports, and the denial of service (DoS) feature. Port-based security includes IEEE 802.1X authentication and port MAC locking. • IEEE 802.1X provides an authentication mechanism to devices connected to the switch. Network access is permitted only to authorized devices (clients). • Port MAC locking is used to enable security on a per-port basis. When a port is locked, only packets with allowable source MAC addresses can be forwarded. All other packets are discarded. Port-MAC locking allows a configurable limit to the number of source MAC addresses that can be learned on a port. NOTE: Port-based security can also be accomplished by using Access Control Lists (ACLs). For information about configuring ACLs, see "Configuring Access Control Lists" on page 523. The topics covered in this chapter include: • IEEE 802.1X • Port Security (Port-MAC Locking) • Denial of Service Configuring Port and System Security 481 IEEE 802.1X What is IEEE 802.1X? The IEEE 802.1X standard provides a means of preventing unauthorized access by supplicants (clients) to the services the switch offers, such as access to the LAN. The 802.1X network has three components: • Supplicant — The client connected to the authenticated port that requests access to the network. • Authenticator — The network device that prevents network access prior to authentication. • Authentication Server — The network server (such as a RADIUS server) that performs the authentication on behalf of the authenticator, and indicates whether the user is authorized to access system services. Figure 19-1 shows the 802.1X network components. Figure 19-1. IEEE 802.1X Network Supplicant Authenticator Authentication Server LAN 482 Configuring Port and System Security As shown in Figure 19-1, the PowerConnect 7000 Series switch is the authenticator and enforces the supplicant (a PC) that is attached to an 802.1X-controlled port to be authenticated by an authentication server (a RADIUS server). The result of the authentication process determines whether the supplicant is authorized to access services on that controlled port. PowerConnect switches support authentication using remote RADIUS or TACACS servers and also support authentication using a local authentication service. Supported security methods for communication with remote servers include MD5, PEAP, EAP-TTL, EAP-TTLS, and EAP-TLS. Only EAP-MD5 is supported when using the local authentication server (IAS). For a list of RADIUS attributes that the switch supports, see "Using RADIUS Servers to Control Management Access" on page 190. What are the 802.1X Port States? The 802.1X port state determines whether to allow or prevent network traffic on the port. A port can configured to be in one of the following 802.1X control modes: • Auto (default) • MAC-based • Force-authorized • Force-unauthorized. These modes control the behavior of the port. The port state is either Authorized or Unauthorized. If the port is in the authorized state, the port sends and receives normal traffic without client port-based authentication. When a port is in an unauthorized state, it ignores supplicant authentication attempts and does not provide authentication services to the client. By default, when 802.1X is globally enabled on the switch, all ports are in Auto, which means the port will be unauthorized until a successful authentication exchange has taken place. In addition to authorized, unauthorized, and automode, the 802.1X mode of a port can be MAC based, as the following section describes. NOTE: Only MAC-Based and Automode actually use 802.1X to authenticate. Authorized and Unauthorized modes are manual overrides. Configuring Port and System Security 483 What is MAC-Based 802.1X Authentication? MAC-based authentication allows multiple supplicants connected to the same port to each authenticate individually. For example, a 5-port hub might be connected to a single port on the switch. Each host connected to the hub must authenticate separately in order to gain access to the network. The hosts are distinguished by their MAC addresses. NOTE: By default, all ports are in VLAN Access mode. A port that uses MACbased authentication should be configured to be in General mode. When multiple hosts (for example, a PC, a printer, and a phone in the same office) are connected to the switch on the same port, each of the connected hosts authenticates separately with the RADIUS server. If a port uses MAC-based 802.1X authentication, the option to use MAC Authentication Bypass (MAB) is available. MAB is a supplemental authentication mechanism that allows 802.1X unaware clients – such as printers, fax machines, and some IP phones — to authenticate to the network using the client MAC address as an identifier. The known and allowable MAC address and corresponding access rights of the client must be pre-populated in the authentication server. When a port configured for MAB receives traffic from an unauthenticated client, the switch (Authenticator): • Sends a EAP Request packet to the unauthenticated client • Waits a pre-determined period of time for a response • Retries – resends the EAP Request packet up to three times • Considers the client to be 802.1X unaware client (if it does not receive an EAP response packet from that client) The authenticator sends a request to the authentication server with the MAC address of the client in a hexadecimal format as the username and the MD5 hash of the MAC address as the password. The authentication server checks its database for the authorized MAC addresses and returns an Access-Accept or an Access-Reject response, depending on whether the MAC address is found in the database. MAB also allows 802.1X-unaware clients to be placed in a RADIUS-assigned VLAN or to apply a specific Filter ID to the client traffic. 484 Configuring Port and System Security NOTE: MAB initiates only after the dot1x guest VLAN period times out. If the client responds to any of the EAPOL identity requests, MAB does not initiate for that client. What is the Role of 802.1X in VLAN Assignment? PowerConnect 7000 Series switches allow a port to be placed into a particular VLAN based on the result of the authentication or type of 802.1X authentication a client uses when it accesses the switch. The authentication server can provide information to the switch about which VLAN to assign the supplicant. When a host connects to a switch that uses an authentication server to authenticate, the host authentication can typically have one of three outcomes: • The host is authenticated. • The host attempts to authenticate but fails because it lacks certain security credentials. • The host is a guest and does not try to authenticate at all (802.1X unaware). You can create three separate VLANs on the switch to handle a host depending on whether the host authenticates, fails the authentication, or is a guest. The RADIUS server informs the switch of the selected VLAN as part of the authentication. Authenticated and Unauthenticated VLANs Hosts that authenticate normally use a VLAN that includes access to network resources. Hosts that fail the authentication might be denied access to the network or placed on a quarantine VLAN with limited network access. Much of the configuration to assign authenticated hosts to a particular VLAN takes place on the 802.1X authenticator server (for example, a RADIUS server). If you use an external RADIUS server to manage VLANs, you configure the server to use Tunnel attributes in Access-Accept messages in order to inform the switch about the selected VLAN. These attributes are defined in RFC 2868, and their use for dynamic VLAN is specified in RFC 3580. Configuring Port and System Security 485 The VLAN attributes defined in RFC3580 are as follows: • Tunnel-Type=VLAN (13) • Tunnel-Medium-Type=802 • Tunnel-Private-Group-ID=VLANID VLANID is 12-bits and has a value between 1 and 4093. Dynamic VLAN Creation If RADIUS-assigned VLANs are enabled though the Authorization Network RADIUS configuration option, the RADIUS server is expected to include the VLAN ID in the 802.1X tunnel attributes of its response message to the switch. If dynamic VLAN creation is enabled on the switch and the RADIUSassigned VLAN does not exist, then the assigned VLAN is dynamically created. This implies that the client can connect from any port and can get assigned to the appropriate VLAN. This gives flexibility for clients to move around the network without much additional configuration required. Guest VLAN The Guest VLAN feature allows a switch to provide a distinguished service to unauthenticated users. This feature provides a mechanism to allow users access to hosts on the guest VLAN. For example, a company might provide a guest VLAN to visitors and contractors to permit network access that allows visitors to connect to external network resources, such as the Internet, with no ability to browse information on the internal LAN. In port-based 802.1X mode, when a client that does not support 802.1X is connected to an unauthorized port that is 802.1X-enabled, the client does not respond to the 802.1X requests from the switch. Therefore, the port remains in the unauthorized state, and the client is not granted access to the network. If a guest VLAN is configured for that port, then the port is placed in the configured guest VLAN and the port is moved to the authorized state, allowing access to the client. However, if the port is in MAC-based 802.1X authentication mode, it will not move to the authorized state. MAC-based mode makes it possible for both authenticated and guest clients to use the same port at the same time. NOTE: MAB and the guest VLAN feature are mutually exclusive on a port. 486 Configuring Port and System Security Client devices that are 802.1X-supplicant-enabled authenticate with the switch when they are plugged into the 802.1X-enabled switch port. The switch verifies the credentials of the client by communicating with an authentication server. If the credentials are verified, the authentication server informs the switch to unblock the switch port and allows the client unrestricted access to the network; i.e., the client is a member of an internal VLAN. Guest VLAN mode can be configured on a per-port basis. If a client does not attempt authentication on a port, and the port is configured for the guest VLAN, the client is assigned to the guest VLAN configured on that port. The port is assigned a guest VLAN ID and is moved to the authorized status. When the guest VLAN is disabled, users authorized by the guest VLAN are removed. What is Monitor Mode? The monitor mode is a special mode that can be enabled in conjunction with 802.1X authentication. Monitor mode provides a way for network administrators to identify possible issues with the 802.1X configuration on the switch without affecting the network access to the users of the switch. It allows network access even in case where there is a failure to authenticate but logs the results of the authentication process for diagnostic purposes. The monitor mode can be configured globally on a switch. If the switch fails to authenticate a user for any reason (for example, RADIUS access reject from RADIUS server, RADIUS timeout, or the client itself is Dot1x unaware), the client is authenticated and is undisturbed by the failure condition(s). The reasons for failure are logged for tracking purposes. Table 19-1 provides a summary of the 802.1X Monitor Mode behavior. Table 19-1. IEEE 802.1X Monitor Mode Behavior Case Sub-case Regular Dot1x Dot1x Monitor Mode RADIUS/IAS Success Success Port State: Permit VLAN: Assigned Filter: Assigned Port State: Permit VLAN: Assigned Filter: Assigned Incorrect NAS Port Port State: Deny Port State: Permit VLAN: Default PVID of the port Configuring Port and System Security 487 Table 19-1. IEEE 802.1X Monitor Mode Behavior (Continued) Case RADIUS/IAS Failure RADIUS Timeout Sub-case Regular Dot1x Dot1x Monitor Mode Invalid VLAN Assignment Port State: Deny Port State: Permit VLAN: Default PVID of the port Invalid Filter-id Port State: Deny Port State: Permit VLAN: Default PVID of the port Bad RADIUS packet Port State: Deny Port State: Permit VLAN: Default PVID of the port Default behavior Port State: Deny Port State: Permit VLAN: Default PVID of the port Unauth VLAN enabled Port State: Permit VLAN: Unauth Port State: Permit VLAN: Unauth Default behavior Port State: Deny Port State: Permit VLAN: Default PVID of the port Unauth VLAN enabled Port State: Deny Port State: Permit VLAN: Unauth Port State: Deny Port State: Permit Guest VLAN enabled Port State: Permit VLAN: Guest Port State: Permit VLAN: Guest MAB Success Case Port State: Permit VLAN: Assigned Filter: Assigned Port State: Permit VLAN: Assigned Filter: Assigned MAB Fail Case Port State: Deny Port State: Permit VLAN: Default PVID of the port EAPOL Timeout Default behavior 3 × EAPOL Timeout (Guest VLAN timer expiry or MAB timer expiry) 488 Configuring Port and System Security Table 19-1. IEEE 802.1X Monitor Mode Behavior (Continued) Case Sub-case Regular Dot1x Dot1x Monitor Mode Supplicant Timeout Port State: Deny Port State: Deny Port/Client Delete Guest Authenticated VLANID through on Guest VLAN Dot1Q Port State: Deny Port State: Permit VLAN: Default PVID of the port How Does the Authentication Server Assign DiffServ Filters? The PowerConnect 7000 Series switches allow the external 802.1X Authenticator or RADIUS server to assign DiffServ policies to users that authenticate to the switch. When a host (supplicant) attempts to connect to the network through a port, the switch contacts the 802.1X authenticator or RADIUS server, which then provides information to the switch about which DiffServ policy to assign the host (supplicant). The application of the policy is applied to the host after the authentication process has completed. For additional guidelines about using an authentication server to assign DiffServ policies, see "Configuring Authentication Server DiffServ Filter Assignments" on page 513. What is the Internal Authentication Server? The Internal Authentication Server (IAS) is a dedicated database for localized authentication of users for network access through 802.1X. In this database, the switch maintains a list of username and password combinations to use for 802.1X authentication. You can manually create entries in the database, or you can upload the IAS information to the switch. If the authentication method for 802.1X is IAS, the switch uses the locally stored list of username and passwords to provide port-based authentication to users instead of using an external authentication server. Authentication using the IAS supports the EAP-MD5 method only. NOTE: The IAS database does not handle VLAN assignments or DiffServ policy assignments. Configuring Port and System Security 489 Default 802.1X Values Table 19-2 lists the default values for the 802.1X features. Table 19-2. Default Port-Based Security Values Feature Description Global 802.1X status Disabled 802.1X authentication method none Per-port 802.1X status Disabled Port state automode Periodic reauthentication Disabled Seconds between reauthentication attempts 3600 Authentication server timeout 30 seconds Resending EAP identity Request 30 seconds Quiet period 60 seconds Supplicant timeout 30 seconds Max EAP request 2 times Maximum number of supplicants per port 16 for MAC-based authentication mode Guest VLAN Disabled Unauthenticated VLAN Disabled Dynamic VLAN creation Disabled RADIUS-assigned VLANs Disabled IAS users none configured Port security Unlocked Port security traps Disabled Maximum learned MAC addresses 100 (when locked) Monitor mode Disabled 490 Configuring Port and System Security Configuring IEEE 802.1X (Web) This section provides information about the OpenManage Switch Administrator pages for configuring and monitoring the IEEE 802.1X features and Port Security on a PowerConnect 7000 Series switch. For details about the fields on a page, click at the top of the page. Dot1x Authentication Use the Dot1x Authentication page to configure the 802.1X administrative mode on the switch and to configure general 802.1X parameters for a port. To display the Dot1x Authentication page, click Switching → Network Security → Dot1x Authentication → Authentication in the navigation panel. Figure 19-2. Dot1x Authentication Configuring Port and System Security 491 Configuring 802.1X Settings on Multiple Ports To configure 802.1X authentication on multiple ports: 1 Open the Dot1x Authentication page. 2 Click Show All to display the Dot1x Authentication Table page. 3 In the Ports list, select the check box in the Edit column for the port to configure. 4 Select the desired settings to change for all ports that are selected for editing. Figure 19-3. Configure Dot1x Settings 5 Click Apply. Re-Authenticating One Port To reauthenticate a port: 1 Open the Dot1x Authentication page. 2 Click Show All. The Dot1x Authentication Table displays. 3 Check Edit to select the Unit/Port to re-authenticate. 4 Check Reauthenticate Now. 5 Click Apply. The authentication process is restarted on the specified port. Re-Authenticating Multiple Ports in the Dot1x Authentication Table To reauthenticate multiple ports: 1 Open the Dot1x Authentication page. 492 Configuring Port and System Security 2 Click Show All. The Dot1x Authentication Table displays. 3 Check Edit to select the Units/Ports to re-authenticate. 4 To re-authenticate on a periodic basis, set Periodic Re-Authentication to Enable, and specify a Re-Authentication Period for all desired ports. 5 To re-authenticate immediately, check Reauthenticate Now for all ports to be re-authenticated. 6 Click Apply. The authentication process is restarted on the specified ports (either immediately or periodically). Changing Administrative Port Control To change the administrative port control: 1 Open the Dot1x Authentication page. 2 Click Show All. The Dot1x Authentication Table displays. 3 Scroll to the right side of the table and select the Edit check box for each port to configure. Change Admin Port Control to Authorized, Unauthorized, or Automode as needed for chosen ports. Only MACBased and Automode actually use 802.1X to authenticate. Authorized and Unauthorized are manual overrides. 4 Click Apply. Admin Port Control is updated for the specified ports, and the device is updated. Authenticated Users The Authenticated Users page is used to display lists of ports that have authenticated users. To display the Authenticated Users page, click Switching → Network Security → Authenticated Users in the navigation panel. Configuring Port and System Security 493 Figure 19-4. Network Security Authenticated Users Port Access Control Configuration Use the Port Access Control Configuration page to globally enable or disable RADIUS-assigned VLANs and to enable Monitor Mode to help troubleshoot 802.1X configuration issues. NOTE: The VLAN Assignment Mode field is the same as the Admin Mode field on the System → Management Security → Authorization Network RADIUS page. To display the Port Access Control Configuration page, click Switching → Network Security → Dot1x Authentication → Monitor Mode → Port Access Control Configuration in the navigation panel. 494 Configuring Port and System Security Figure 19-5. Port Access Control Configuration Port Access Control History Log Summary Use the Port Access Control History Log Summary page to view log messages about 802.1X client authentication attempts. The information on this page can help you troubleshoot 802.1X configuration issues. To display the Port Access Control History Log Summary page, click Port Access Control Configuration page, click Switching → Network Security → Dot1x Authentication → Monitor Mode → Port Access Control History Log Summary in the navigation panel. Figure 19-6. Port Access Control History Log Summary Configuring Port and System Security 495 Internal Authentication Server Users Configuration Use the Internal Authentication Server Users Configuration page to add users to the local IAS database and to view the database entries. To display the Internal Authentication Server Users Configuration page, click System → Management Security → Internal Authentication Server Users Configuration in the navigation panel. Figure 19-7. Internal Authentication Server Users Configuration NOTE: If no users exist in the IAS database, the IAS Users Configuration Page does not display the fields shown in the image. Adding Users to the IAS Database To add IAS users: 1 Open the Internal Authentication Server Users Configuration page. 2 Click Add to display the Internal Authentication Server Users Add page. 3 Specify a username and password in the appropriate fields. 496 Configuring Port and System Security Figure 19-8. Adding an IAS User 4 Click Apply. To view the Internal Authentication Server Users Table page, click Show All. Removing an IAS User To delete an IAS user: 1 Open the Internal Authentication Server Users Configuration page. 2 From the User menu, select the user to remove, select the user to remove. 3 Select the Remove check box. Figure 19-9. Removing an IAS User 4 Click Apply. Configuring Port and System Security 497 Configuring IEEE 802.1X (CLI) This section provides information about commands you use to configure 802.1X and Port Security settings. For additional information about the commands in this section, see the PowerConnect 7000 Series CLI Reference Guide at support.dell.com/manuals. Configuring Basic 802.1X Authentication Settings Beginning in Privileged EXEC mode, use the following commands to enable and configure 802.1X authentication on the switch. Command Purpose configure Enter Global Configuration mode. aaa accounting dot1x default Sets 802.1X accounting to the default operational mode aaa authentication dot1x default method1 Specify the authentication method to use to authenticate 802.1X clients that connect to the switch. method1—The method keyword can be radius, none, or ias. dot1x system-authcontrol Globally enable 802.1X authentication on the switch. interface interface Enter interface configuration mode for the specified interface. The interface variable includes the interface type and number, for example gigabitethernet 1/0/3. You can also specify a range of interfaces with the interface range command, for example, interface range gigabitethernet 1/0/8-12 configures interfaces 8, 9, 10, 11, and 12. 498 Configuring Port and System Security Command Purpose dot1x port-control {force-authorized | force-unauthorized | auto | mac-based} Specify the 802.1X mode for the port. NOTE: For standard 802.1X implementations in which one client is connected to one port, use the dot1x port-control auto command to enable 802.1X authentication on the port. • auto — Enables 802.1X authentication on the interface and causes the port to transition to the authorized or unauthorized state based on the 802.1X authentication exchange between the switch and the client. • force-authorized — Disables 802.1X authentication on the interface and causes the port to transition to the authorized state without any authentication exchange required. The port sends and receives normal traffic without 802.1X-based authentication of the client. • force-unauthorized — Denies all access through this interface by forcing the port to transition to the unauthorized state, ignoring all attempts by the client to authenticate. The switch cannot provide authentication services to the client through the interface. • mac-based — Enables 802.1X authentication on the interface and allows multiple hosts to authenticate on a single port. The hosts are distinguished by their MAC addresses. dot1x mac-auth-bypass If the 802.1X mode on the interface is mac-based, you can optionally use this command to enable MAB on an interface. CTRL + Z Exit to Privileged EXEC mode. show dot1x View the current 802.1X configuration. show dot1x clients {all | View information about 802.1X clients that have successfully authenticated and are connected to the switch. The interface variable includes the interface type and number. interface} show dot1x users [username username] View the 802.1X authenticated users for the switch. Configuring Port and System Security 499 NOTE: To enable 802.1X Monitor Mode to help troubleshoot authentication issues, use the dot1x system-auth-control monitor command in Global Configuration mode. To view 802.1X authentication events and information, use the show dot1x authentication-history { | all} [failed-auth-only] [detail] command in Privileged EXEC mode. To clear the history, use the clear dot1x authenticationhistory command. Configuring Additional 802.1X Interface Settings Beginning in Privileged EXEC mode, use the following commands to configure 802.1X interface settings such as the reauthentication period and switch-to-client retransmission time. Command Purpose configure Enter Global Configuration mode. interface interface Enter interface configuration mode for the specified interface. The interface variable includes the interface type and number, for example gigabitethernet 1/0/3. You can also specify a range of interfaces with the interface range command, for example, interface range gigabitethernet 1/0/8-12 configures interfaces 8, 9, 10, 11, and 12. dot1x reauthentication Enable periodic re-authentication of the client. dot1x timeout reauthperiod seconds Set the number of seconds between re-authentication attempts. dot1x timeout servertimeout seconds Set the time that the switch waits for a response from the authentication server. dot1x timeout tx-period Set the number of seconds that the switch waits for a response to an Extensible Authentication Protocol (EAP)request/identity frame from the client before resending the request. seconds dot1x timeout quietperiod seconds 500 Set the number of seconds that the switch remains in the quiet state following a failed authentication exchange (for example, the client provided an invalid password). Configuring Port and System Security Command Purpose dot1x timeout supptimeout seconds Set the time that the switch waits for a response before retransmitting an Extensible Authentication Protocol (EAP)-request frame to the client. dot1x max-req count Set the maximum number of times that the switch sends an Extensible Authentication Protocol (EAP)-request frame (assuming that no response is received) to the client before restarting the authentication process. dot1x max-users users Set the maximum number of clients supported on the port when MAC-based 802.1X authentication is enabled on the port. CTRL + Z Exit to Privileged EXEC mode. dot1x re-authenticate [interface] Manually initiate the re-authentication of all 802.1Xenabled ports or on the specified 802.1X-enabled port. The interface variable includes the interface type and number. dot1x initialize [interface] Start the initialization sequence on all ports or on the specified port. NOTE: This command is valid only if the port-control mode for the specified port is auto or MAC-based. interface] show dot1x [interface View 802.1X settings for the switch or for the specified interface. show dot1x interface View 802.1X statistics for the specified interface. interface statistics Configuring 802.1X Settings for RADIUS-Assigned VLANs Beginning in Privileged EXEC mode, use the following commands to configure 802.1X settings that affect the RADIUS-assigned VLAN. Command Purpose configure Enter Global Configuration mode. aaa authorization network default radius Allow the RADIUS server to assign VLAN IDs to clients. Configuring Port and System Security 501 Command Purpose dot1x dynamic-vlan enable If the RADIUS assigned VLAN does not exist on the switch, allow the switch to dynamically create the assigned VLAN. interface interface Enter interface configuration mode for the specified interface. The interface variable includes the interface type and number, for example gigabitethernet 1/0/3. You can also specify a range of interfaces with the interface range command, for example, interface range gigabitethernet 1/0/8-12 configures interfaces 8, 9, 10, 11, and 12. dot1x guest-vlan vlan-id Specify the guest VLAN. dot1x unauth-vlan vlan- Specify the unauthenticated VLAN. The VLAN must already have been created. id CTRL + Z Exit to Privileged EXEC mode. show dot1x advanced View the current 802.1X configuration. interface NOTE: When dynamically creating VLANs, the uplink port should be in trunk mode so that it will automatically participate in all dynamically-created VLANs. Otherwise, the supplicant may be placed in a VLAN that does not go beyond the switch because no other ports are participating. 502 Configuring Port and System Security Configuring Internal Authentication Server Users Beginning in Privileged EXEC mode, use the following commands to add users to the IAS database and to use the database for 802.1X authentication. Command Purpose configure Enter Global Configuration mode. aaa ias-user username Add a user to the IAS user database. This command also changes the mode to the AAA User Config mode. password password [encrypted] Configure the password associated with the user. CTRL + Z Exit to Privileged EXEC mode. show aaa ias-users View all configured IAS users. clear aaa ias-users Delete all IAS users from the database. user IEEE 802.1X Configuration Examples This section contains the following examples: • Configuring 802.1X Authentication • Controlling Authentication-Based VLAN Assignment • Allowing Dynamic VLAN Creation of RADIUS-Assigned VLANs • Configuring Authentication Server DiffServ Filter Assignments Configuring 802.1X Authentication The network in this example requires clients to use 802.1X authentication to access the network through the switch ports. The administrator must configure the following settings on systems other than the switch before configuring the switch: 1 Add the users to the client database on the Authentication Server, such as a RADIUS server with Cisco® Secure Access Control Server (ACS) software. 2 Configure the settings on the client, such a PC running Microsoft® Windows, to require 802.1X authentication. Configuring Port and System Security 503 The switch uses an authentication server with an IP address of 10.10.10.10 to authenticate clients. Port 7 is connected to a printer in the unsecured area. The printer is an 802.1X unaware client, so Port 7 is configured to use MACbased authentication with MAB. NOTE: The printer requires an entry in the client database that uses the printer MAC address as the username. An IP phone is directly connected to Port 8, and a PC is connected to the IP phone. Both devices are authenticated through MAC-based authentication, which allows multiple hosts to authenticate on a single port. The hosts are distinguished by their MAC addresses, and hosts authenticate separately with the RADIUS server. Port 9 is connected to a server in a part of the network that has secure physical access (i.e. the doors to the wiring closet and data center are locked), so this port is set to the Authorized state, meaning that the device connected to this port does not need to authenticate using 802.1X. Port 24 is the uplink to a router and is also in the Authorized state. 504 Configuring Port and System Security Figure 19-10. 802.1X Example Physically Unsecured Devices Clients (Ports 1 and 3) Physically Secured Devices Authentication Server (RADIUS) PowerConnect Switch Clients (Port 8) Printer (Port 7) LAN Uplink (Port 24) LAN Server (Port 9) The following example shows how to configure the example shown in Figure 19-10. 1 Configure the RADIUS server IP address and shared secret (secret). console#configure console(config)#radius-server host 10.10.10.10 console(Config-radius)#exit console(config)#radius-server key secret console(config)#exit 2 Enable 802.1X port-based access control on the switch. console(config)#dot1x system-auth-control 3 Configure ports 9 and 24 to be in the Authorized state, which allows the devices to connect to these ports to access the switch services without authentication. console(config)#interface range gi1/0/9,gi1/0/24 Configuring Port and System Security 505 console(config-if)#dot1x port-control forceauthorized console(config-if)#exit 4 Configure Port 7 to require MAC-based authentication with MAB. console(config)#interface gi1/0/7 console(config-if-Gi1/0/7)#dot1x port-control macbased console(config-if-Gi1/0/7)#dot1x mac-auth-bypass 5 Set the port to an 802.1Q VLAN. The port must be in general mode in order to enable MAC-based 802.1X authentication. console(config-if-Gi1/0/7)#switchport mode general console(config-if-Gi1/0/7)#exit 6 Enable MAC-based authentication on port 8 and limit the number of devices that can authenticate on that port to 2. console(config)#interface gi1/0/8 console(config-if-Gi1/0/8)#dot1x port-control macbased console(config-if-Gi1/0/8)#dot1x max-users 2 7 Set Port 8 to switchport mode general. The port must be in general mode in order to enable MAC-based 802.1X authentication. console(config-if-Gi1/0/8)#switchport mode general console(config-if-Gi1/0/8)#exit console(config)#exit 8 View the client connection status. When the clients on Ports 1, 3, and 7(supplicants), attempt to communicate via the switch, the switch challenges the supplicants for 802.1X credentials. The switch encrypts the provided information and transmits it to the RADIUS server. If the RADIUS server grants access, the system sets the 802.1X port state of the interface to authorized and the supplicants are able to access network resources. console#show dot1x clients all Interface...................................... User Name...................................... Supp MAC Address............................... Session Time................................... 506 Configuring Port and System Security Gi1/0/1 aoversmit 0012.1753.031A 756 Filter Id...................................... VLAN Assigned.................................. 1 (Default) Interface...................................... User Name...................................... Supp MAC Address............................... Session Time................................... Filter Id...................................... VLAN Assigned.................................. Gi1/0/3 dflint 0004.5A55.EFAD 826 Interface...................................... User Name...................................... Supp MAC Address............................... Session Time................................... Filter Id...................................... VLAN Assigned.................................. Gi1/0/7 0006.6B33.06BA 0006.6B33.06BA 826 1 (Default) 1 (Default) 9 View a summary of the port status. console#show dot1x Administrative Mode............... Enabled Port Admin Oper Mode Mode ------- ---------------- -----------Gi1/0/1 auto Authorized Gi1/0/2 auto N/A Gi1/0/3 auto Authorized Gi1/0/4 auto N/A Gi1/0/5 auto N/A Gi1/0/6 auto N/A Gi1/0/7 mac-based Authorized Gi1/0/8 mac-based N/A Gi1/0/9 force-authorized Authorized Gi1/0/10 force-authorized Authorized Gi1/0/11 auto N/A --More-- or (q)uit Reauth Reauth Control Period -------- ---------FALSE 3600 FALSE 3600 FALSE 3600 FALSE 3600 FALSE 3600 FALSE 3600 FALSE 3600 FALSE 3600 FALSE 3600 FALSE 3600 FALSE 3600 Configuring Port and System Security 507 10 View 802.1X information about Port 8. console#show dot1x interface gi1/0/8 Administrative Mode............... Enabled Dynamic VLAN Creation Mode........ Enabled Monitor Mode...................... Disabled Port ------Gi1/0/8 Admin Oper Reauth Reauth Mode Mode Control Period ---------------- ------------ -------- ---------mac-based Authorized FALSE 3600 Quiet Period................................... Transmit Period................................ Maximum Requests............................... Max Users...................................... VLAN Assigned.................................. Supplicant Timeout............................. Guest-vlan Timeout............................. Server Timeout (secs).......................... MAB mode (configured).......................... MAB mode (operational)......................... 60 30 2 2 1 (Default) 30 90 30 Disabled Disabled Controlling Authentication-Based VLAN Assignment The network in this example uses three VLANs to control access to network resources. When a client connects to the network, it is assigned to a particular VLAN based on one of the following events: • It attempts to contact the 802.1X server and is authenticated. • It attempts to contact the 802.1X server and fails to authenticate. • It does not attempt to contact the 802.1X server. The following table describes the three VLANs: VLAN ID VLAN Name VLAN Purpose 100 Authorized Data from authorized clients 200 Unauthorized Data traffic from clients that fail the authentication with the RADIUS server 300 Guest Data traffic from clients that do not attempt to authenticate with the RADIUS server 508 Configuring Port and System Security NOTE: Dynamic VLAN creation applies only to authorized ports. The VLANs for unauthorized and guest users must be configured on the switch and cannot be dynamically created based on RADIUS-based VLAN assignment. The commands in this example show how to configure the switch to control VLAN assignment for the example network. This example also contains commands to configure the uplink, or trunk, port (a port connected to a router or the internal network), and to configure the downlink, or access, ports (ports connected to one or more hosts). Ports 1–23 are downstream ports. Port 24 is an uplink port. An external RADIUS server handles the VLAN assignment. NOTE: The configuration to control the VLAN assignment for authorized users is done on the external RADIUS server. Configuring Port and System Security 509 To configure the switch: 1 Create the VLANs and configure the VLAN names. console(config)#vlan 100 console(config-vlan100)#name Authorized console(config-vlan100)#exit console(config)#vlan 200 console(config-vlan200)#name Unauthorized console(config-vlan200)#exit console(config)#vlan 300 console(config-vlan300)#name Guest console(config-vlan300)#exit 2 Configure information about the external RADIUS server the switch uses to authenticate clients. The RADIUS server IP address is 10.10.10.10, and the shared secret is qwerty123. console(config)#radius-server key qwerty123 console(config)#radius-server host 10.10.10.10 console(Config-auth-radius)#exit 3 Enable 802.1X on the switch. console(config)#dot1x system-auth-control 4 Create a default authentication login list and use the RADIUS server for port-based authentication for connected clients. console(config)#aaa authentication dot1x default radius 5 Allow the switch to accept VLAN assignments by the RADIUS server. console(config)#aaa authorization network default radius 6 Enter interface configuration mode for the downlink ports. console(config)#interface range gi1/0/1-23 7 Set the downlink ports to the access mode because each downlink port connects to a single host that belongs to a single VLAN. console(config-if)#switchport mode access 510 Configuring Port and System Security 8 Enable periodic reauthentication of the client on the ports and set the number of seconds to wait between reauthentication attempts to 300 seconds. Reauthentication is enabled to increase security. If the client information is removed from the RADIUS server after it has been authenticated, the client will be denied access when it attempts to reauthenticate. console(config-if)#dot1x reauthentication console(config-if)#dot1x timeout re-authperiod 300 9 Set the unauthenticated VLAN on the ports to VLAN 200 so that any client that connects to one of the ports and fails the 802.1X authentication is placed in VLAN 200. console(config-if)#dot1x unauth-vlan 200 10 Set the guest VLAN on the ports to VLAN 300. This command automatically enables the Guest VLAN Mode on the downlink ports. Any client that connects to the port and does not attempt to authenticate is placed on the guest VLAN. console(config-if)#dot1x guest-vlan 300 console(config-if)#exit 11 Enter Interface Configuration mode for port 24, the uplink (trunk) port. console(config)#interface gi1/0/24 12 Disable 802.1X authentication on the interface. This causes the port to transition to the authorized state without any authentication exchange required. This port does not connect to any end-users, so there is no need for 802.1X-based authentication. console(config-if-Gi1/0/24)#dot1x port-control force-authorized 13 Set the uplink port to trunk mode so that it accepts tagged traffic and transmits it to the connected device (another switch or router). console(config-if-Gi1/0/24)#switchport mode trunk Configuring Port and System Security 511 Allowing Dynamic VLAN Creation of RADIUS-Assigned VLANs The network in this example uses a RADIUS server to provide VLAN assignments to host that connect to the switch. In this example, the VLANs are not configured on the switch. Instead, the switch is configured to allow the dynamic creation of VLANs when a RADIUS-assigned VLAN does not already exist on the switch. In this example, Ports 1–23 are configured as downlink, or access, ports, and Port 24 is the trunk port. As a trunk port, Port 24 is automatically added as a member to all VLANs that are statically or dynamically configured on the switch. However, the network administrator in this example has determined that traffic in VLANs 1000–2000 should not be forwarded on the trunk port, even if the RADIUS server assigns a connected host to a VLAN in this range, and the switch dynamically creates the VLAN. NOTE: The configuration to control the VLAN assignment for hosts is done on the external RADIUS server. To configure the switch: 1 Configure information about the external RADIUS server the switch uses to authenticate clients. The RADIUS server IP address is 10.10.10.10, and the shared secret is qwerty123. console(config)#radius-server key qwerty123 console(config)#radius-server host 10.10.10.10 console(Config-auth-radius)#exit 2 Enable 802.1X on the switch. console(config)#dot1x system-auth-control 3 Create a default authentication login list and use the RADIUS server for port-based authentication for connected clients. console(config)#aaa authentication dot1x default radius 4 Allow the switch to accept VLAN assignments by the RADIUS server. console(config)#aaa authorization network default radius 512 Configuring Port and System Security 5 Allow the switch to dynamically create VLANs when a RADIUS-assigned VLAN does not exist on the switch. console(config)#dot1x dynamic-vlan enable 6 Enter interface configuration mode for the downlink ports. console(config)#interface range gi1/0/1-23 7 Set the downlink ports to the access mode because each downlink port connects to a single host that belongs to a single VLAN. console(config-if)#switchport mode access console(config-if)#exit 8 Enter Interface Configuration mode for port 24, the uplink (trunk) port. console(config)#interface gi1/0/24 9 Disable 802.1X authentication on the interface. This causes the port to transition to the authorized state without any authentication exchange required. This port does not connect to any end-users, so there is no need for 802.1X-based authentication. console(config-if-Gi1/0/24)#dot1x port-control force-authorized 10 Set the uplink port to trunk mode so that it accepts tagged traffic and transmits it to the connected device (another switch or router). console(config-if-Gi1/0/24)#switchport mode trunk 11 Forbid the trunk from forwarding traffic that has VLAN tags for any VLAN from 1000–2000, inclusive. console(config-if-Gi1/0/24)#switchport trunk allowed vlan remove 1000-2000 console(config-if-Gi1/0/24)#exit Configuring Authentication Server DiffServ Filter Assignments To enable DiffServ filter assignment by an external server, the following conditions must be true: • The port that the host is connected to must be enabled for MAC-based port access control by using the following command in Interface Config mode: dot1x port-control mac-based Configuring Port and System Security 513 • The RADIUS or 802.1X server must specify the policy to assign. For example, if the DiffServ policy to assign is named internet_access, include the following attribute in the RADIUS or 802.1X server configuration: Filter-id = “internet_access” • The DiffServ policy specified in the attribute must already be configured on the switch, and the policy names must be identical. For information about configuring a DiffServ policy, see "DiffServ Configuration Examples" on page 1123. The example "Providing Subnets Equal Access to External Network" on page 1123, describes how to configure a policy named internet_access. If you use an authentication server to assign DiffServ policies to an authenticated user, note the following guidelines: • If the policy specified within the server attribute does not exist on the switch, authentication will fail. • Do not delete policies used as the filter ID in the RADIUS server while 802.1X is enabled. • Do not use the DiffServ service-policy command to apply the filter to an interface if you configure the RADIUS server or 802.1X authenticator to assign the DiffServ filter. In the following example, Company XYZ uses IEEE 802.1X to authenticate all users. Contractors and temporary employees at Company XYZ are not permitted to have access to SSH ports, and data rates for Web traffic is limited. When a contractor is authenticated by the RADIUS server, the server assigns a DiffServ policy to control the traffic restrictions. The network administrator configures two DiffServ classes: cl-ssh and cl-http. The class cl-ssh matches all incoming SSH packets. The class cl-http matches all incoming HTTP packets. Then, the administrator configures a traffic policy called con-pol and adds the cl-ssh and cl-http. The policy is configured so that that SSH packets are to be dropped, and HTTP data rates are limited to 1 MB with a burst size of 64 Kbps. HTTP traffic that exceeds the limit is dropped. The host ports, ports 1–23, are configured to use MAC-based dot1X authentication to allow the DiffServ policy to be applied. Finally, the administrator configures the RADIUS server with the attribute Filter-id = “con-pol”. 514 Configuring Port and System Security To configure the switch : 1 Configure the DiffServ traffic class that matches SSH traffic. console#configure console(config)#class-map match-all cl-ssh console(config-classmap)#match srcl4port 23 console(config-classmap)#exit 2 Configure the DiffServ traffic class that matches HTTP traffic. console(config)#class-map match-all cl-http console(config-classmap)#match srcl4port 80 console(config-classmap)#exit 3 Configure the DiffServ policy. console(config)#policy-map con-pol in console(config-policy-map)#class cl-ssh console(config-policy-classmap)#drop console(config-policy-classmap)#exit console(config-policy-map)#class cl-http console(config-policy-classmap)#police-simple 1000000 64 conform-action transmit violate-action drop console(config-policy-classmap)#exit console(config-policy-map)#exit 4 Enable DiffServ on the switch. console(config)#diffserv 5 Configure information about the external RADIUS server the switch uses to authenticate clients. The RADIUS server IP address is 10.10.10.10, and the shared secret is qwerty123. console(config)#radius-server key qwerty123 console(config)#radius-server host 10.10.10.10 console(Config-auth-radius)#exit 6 Enable 802.1X on the switch. console(config)#dot1x system-auth-control 7 Create a default authentication login list and use the RADIUS server for port-based authentication for connected clients. Configuring Port and System Security 515 console(config)#aaa authentication dot1x default radius 8 Enter Interface Configuration mode for ports 1–23 and enable MACbased authentication. console(config)#interface range gi1/0/1-23 console(config-if)#dot1x port-control mac-based 9 Set the ports to an 802.1Q VLAN. The ports must be in general mode in order to enable MAC-based 802.1X authentication. console(config-if)#switchport mode general console(config-if)#exit console(config)#exit 516 Configuring Port and System Security Port Security (Port-MAC Locking) The Port Security feature allows you to limit the number of source MAC addresses that can be learned on a port. If a port reaches the configured limit, any other addresses beyond that limit are not learned and the frames are discarded. Frames with a source MAC address that has already been learned will be forwarded. The purpose of this feature, which is also known as port-MAC locking, is to help secure the network by preventing unknown devices from forwarding packets into the network. For example, to ensure that only a single device can be active on a port, you can set the number of allowable dynamic addresses to one. After the MAC address of the first device is learned, no other devices will be allowed to forward frames into the network. When link goes down on a port, all of the dynamically locked addresses are cleared from the source MAC address table the feature maintains. When the link is restored, that port can once again learn addresses up to the specified limit. The port can learn MAC addresses dynamically, and you can manually specify a list of static MAC addresses for a port. Default 802.1X Values Table 19-2 lists the default values for the Port Security feature. Table 19-3. Default Port Security Values Feature Description Port security Unlocked Port security traps Disabled Maximum learned MAC addresses 100 (when locked) Monitor mode Disabled Configuring Port Security Configuration (Web) This section provides information about the OpenManage Switch Administrator pages for configuring and monitoring the IEEE 802.1X features and Port Security on a PowerConnect 7000 Series switch. For details about the fields on a page, click at the top of the page. Configuring Port and System Security 517 Port Security Use the Port Security page to enable MAC locking on a per-port basis. When a port is locked, you can limit the number of source MAC addresses that are allowed to transmit traffic on the port. To display the Port Security page, click Switching → Network Security → Port Security in the navigation panel. Figure 19-11. Network Security Port Security Configuring Port Security Settings on Multiple Ports To configure port security on multiple ports: 1 Open the Port Security page. 2 Click Show All to display the Port Security Table page. 3 In the Ports list, select the check box in the Edit column for the port to configure. 4 Select the desired settings for all ports that are selected for editing. 518 Configuring Port and System Security Figure 19-12. Configure Port Security Settings 5 Click Apply. Configuring Port and System Security 519 Configuring Port Security (CLI) Beginning in Privileged EXEC mode, use the following commands to enable port security on an interface to limit the number of source MAC addresses that can be learned. Command Purpose configure Enter Global Configuration mode. interface interface Enter interface configuration mode for the specified interface. The interface variable includes the interface type and number, for example gigabitethernet 1/0/3. You can also specify a range of interfaces with the interface range command, for example, interface range gigabitethernet 1/0/8-12 configures interfaces 8, 9, 10, 11, and 12. port security [discard] [trap seconds] Enable port security on the port. This prevents the switch from learning new addresses on this port after the maximum number of addresses has been learned. • discard — Discards frames with unlearned source addresses. This is the default if no option is indicated. • trap seconds — Sends SNMP traps and defines the minimal amount of time in seconds between two consecutive traps. (Range: 1–1000000) addr port security max max- Set the maximum number of MAC addresses that can be learned on the port while port security is enabled. CTRL + Z Exit to Privileged EXEC mode. show ports security [interface] View port security settings on all interfaces or the specified interface. show ports security addresses [interface] View the current MAC addresses that have been learned on all ports or the specified port. 520 Configuring Port and System Security Denial of Service Denial of Service (DoS) refers to the exploitation of a variety of vulnerabilities which would interrupt the service of a host or make a network unstable. Use the Denial of Service page to configure settings to help prevent DoS attacks. DoS protection is disabled by default. To display the Denial of Service page, click System → Management Security → Denial of Service in the navigation panel. Figure 19-13. Denial of Service Configuring Port and System Security 521 522 Configuring Port and System Security 20 Configuring Access Control Lists This chapter describes how to configure Access Control Lists (ACLs), including IPv4, IPv6, and MAC ACLs. This chapter also describes how to configure time ranges that can be applied to any of the ACL types. The topics covered in this chapter include: • ACL Overview • Configuring ACLs (Web) • Configuring ACLs (CLI) • ACL Configuration Examples ACL Overview Access Control Lists (ACLs) are a collection of permit and deny conditions, called rules, that provide security by blocking unauthorized users and allowing authorized users to access specific resources. ACLs can also provide traffic flow control, restrict contents of routing updates, and decide which types of traffic are forwarded or blocked. ACLs can reside in a firewall router, a router connecting two internal networks, or a Layer 3 switch, such as a PowerConnect 7000 Series switch. You can also create an ACL that limits access to the management interfaces based on the connection method (for example, Telnet or HTTP) and/or the source IP address. The PowerConnect 7000 Series switches support ACL configuration in both the ingress and egress direction. Egress ACLs provide the capability to implement security rules on the egress flows (traffic leaving a port) rather than the ingress flows (traffic entering a port). Ingress and egress ACLs can be applied to any physical port, port-channel (LAG), or VLAN routing port. Configuring Access Control Lists 523 Depending on whether an ingress or egress ACL is applied to a port, when the traffic enters (ingress) or leaves (egress) a port, the ACL compares the criteria configured in its rules, in order, to the fields in a packet or frame to check for matching conditions. The ACL forwards or blocks the traffic based on the rules. NOTE: Every ACL is terminated by an implicit deny all rule, which covers any packet not matching a preceding explicit rule. You can set up ACLs to control traffic at Layer 2, Layer 3, or Layer 4. MAC ACLs operate on Layer 2. IP ACLs operate on Layers 3 and 4. PowerConnect 7000 Series switches support both IPv4 and IPv6 ACLs. What Are MAC ACLs? MAC ACLs are Layer 2 ACLs. You can configure the rules to inspect the following fields of a packet: • Source MAC address • Source MAC mask • Destination MAC address • Destination MAC mask • VLAN ID • Class of Service (CoS) (802.1p) • EtherType L2 ACLs can apply to one or more interfaces. Multiple access lists can be applied to a single interface; sequence number determines the order of execution. You can assign packets to queues using the assign queue option. 524 Configuring Access Control Lists What Are IP ACLs? IP ACLs classify for Layers 3 and 4 on IPv4 or IPv6 traffic. Each ACL is a set of up to ten rules applied to inbound traffic. Each rule specifies whether the contents of a given field should be used to permit or deny access to the network, and may apply to one or more of the following fields within a packet: • Destination IP with wildcard mask • Destination L4 Port • Every Packet • IP DSCP • IP Precedence • IP TOS • Protocol • Source IP with wildcard mask • Source L4 port • Destination Layer 4 port What Is the ACL Redirect Function? The redirect function allows traffic that matches a permit rule to be redirected to a specific physical port or LAG instead of processed on the original port. The redirect function and mirror function are mutually exclusive. In other words, you cannot configure a given ACL rule with mirror and redirect attributes. What Is the ACL Mirror Function? ACL mirroring provides the ability to mirror traffic that matches a permit rule to a specific physical port or LAG. Mirroring is similar to the redirect function, except that in flow-based mirroring a copy of the permitted traffic is delivered to the mirror interface while the packet itself is forwarded normally through the device. You cannot configure a given ACL rule with both mirror and redirect attributes. Configuring Access Control Lists 525 Using ACLs to mirror traffic is considered to be flow-based mirroring since the traffic flow is defined by the ACL classification rules. This is in contrast to port mirroring, where all traffic encountered on a specific interface is replicated on another interface. What Is ACL Logging ACL Logging provides a means for counting the number of “hits” against an ACL rule. When you configure ACL Logging, you augment the ACL deny rule specification with a "log" parameter that enables hardware hit count collection and reporting. The switch uses a fixed five minute logging interval, at which time trap log entries are written for each ACL logging rule that accumulated a non-zero hit count during that interval. You cannot configure the logging interval. What Are Time-Based ACLs? The time-based ACL feature allows the switch to dynamically apply an explicit ACL rule within an ACL for a predefined time interval by specifying a time range on a per-rule basis within an ACL, so that the time restrictions are imposed on the ACL rule. With a time-based ACL, you can define when and for how long an individual rule of an ACL is in effect. To apply a time to an ACL, first you define a specific time interval and then apply it to an individual ACL rule so that it is operational only during the specified time range, for example, during a specified time period or on specified days of the week. A time range can be absolute (specific time) or periodic (recurring). If an absolute and periodic time range entry are defined within the same time range, the periodic timer is active only when the absolute timer is active. NOTE: Adding a conflicting periodic time range to an absolute time range will cause the time range to become inactive. For example, consider an absolute time range from 8:00 AM Tuesday March 1st 2011 to 10 PM Tuesday March 1st 2011. Adding a periodic entry using the 'weekend' keyword will cause the time-range to become inactive because Tuesdays are not on the weekend. 526 Configuring Access Control Lists A named time range can contain up to 10 configured time ranges. Only one absolute time range can be configured per time range. During the ACL configuration, you can associate a configured time range with the ACL to provide additional control over permitting or denying a user access to network resources. Benefits of using time-based ACLs include: • Providing more control over permitting or denying a user access to resources, such as an application (identified by an IP address/mask pair and a port number). • Providing control of logging messages. Individual ACL rules defined within an ACL can be set to log traffic only at certain times of the day so you can simply deny access without needing to analyze many logs generated during peak hours. What Are the ACL Limitations? The following limitations apply to ingress and egress ACLs. • Maximum of 100 ACLs. • Maximum rules per ACL is a maximum of 1023 rules, with 1023 ingress and 511 egress IPv4 rules or 509 ingress and 253 egress IPv6 rules. • You can configure mirror or redirect attributes for a given ACL rule, but not both. • The PowerConnect 7000 Series switches support a limited number of counter resources, so it may not be possible to log every ACL rule. You can define an ACL with any number of logging rules, but the number of rules that are actually logged cannot be determined until the ACL is applied to an interface. Furthermore, hardware counters that become available after an ACL is applied are not retroactively assigned to rules that were unable to be logged (the ACL must be un-applied then re-applied). Rules that are unable to be logged are still active in the ACL for purposes of permitting or denying a matching packet. If console logging is enabled and the severity is set to Info (6) or a lower severity, a log entry may appear on the screen. • The order of the rules is important: when a packet matches multiple rules, the first rule takes precedence. Also, once you define an ACL for a given port, all traffic not specifically permitted by the ACL is denied access. Configuring Access Control Lists 527 NOTE: The actual number of ACLs and rules supported depends on the resources consumed by other processes and configured features running on the switch. How Are ACLs Configured? To configure ACLs, follow these steps: 1 Create a MAC ACL by specifying a name. 2 Create an IP ACL by specifying a number. 3 Add new rules to the ACL. 4 Configure the match criteria for the rules. 5 Apply the ACL to one or more interfaces. Preventing False ACL Matches Be sure to specify ACL access-list, permit, and deny rule criteria as fully as possible to avoid false matches. This is especially important in networks with protocols such as FCoE that have newly-introduced EtherType values. For example, rules that specify a TCP or UDP port value should also specify the TCP or UDP protocol and the IPv4 or IPv6 EtherType. Rules that specify an IP protocol should also specify the EtherType value for the frame. In general, any rule that specifies matching on an upper-layer protocol field should also include matching constraints for each of the lower-layer protocols. For example, a rule to match packets directed to the well-known UDP port number 22 (SSH) should also include matching constraints on the IP protocol field (protocol=0x11 or UDP) and the EtherType field (EtherType= 0x0800 or IPv4). Figure 20-1 lists commonly-used EtherTypes numbers: Table 20-1. Common EtherType Numbers EtherType Protocol 0x0800 Internet Protocol version 4 (IPv4) 0x0806 Address Resolution Protocol (ARP) 0x0842 Wake-on LAN Packet 0x8035 Reverse Address Resolution Protocol (RARP) 0x8100 VLAN tagged frame (IEEE 802.1Q) 528 Configuring Access Control Lists Table 20-1. Common EtherType Numbers (Continued) EtherType Protocol 0x86DD Internet Protocol version 6 (IPv6) 0x8808 MAC Control 0x8809 Slow Protocols (IEEE 802.3) 0x8870 Jumbo frames 0x888E EAP over LAN (EAPOL – 802.1x) 0x88CC Link Layer Discovery Protocol 0x8906 Fibre Channel over Ethernet 0x8914 FCoE Initialization Protocol 0x9100 Q in Q Figure 20-2 lists commonly-used IP protocol numbers: \ Table 20-2. Common IP Protocol Numbers IP Protocol Number Protocol 0x00 IPv6 Hop-by-hop option 0x01 ICMP 0x02 IGMP 0x06 TCP 0x08 EGP 0x09 IGP 0x11 UDP Configuring Access Control Lists 529 Configuring ACLs (Web) This section provides information about the OpenManage Switch Administrator pages for configuring and monitoring ACLs on a PowerConnect 7000 Series switch. For details about the fields on a page, click at the top of the page. IP ACL Configuration Use the IP ACL Configuration page to add or remove IP-based ACLs. To display the IP ACL Configuration page, click Switching → Network Security → Access Control Lists → IP Access Control Lists → Configuration in the navigation panel. Figure 20-1. IP ACL Configuration Adding an IPv4 ACL To add an IPv4 ACL: 1 Open the IP ACL Configuration page. 2 Click Add to display the Add IP ACL page. 3 Specify an ACL name. 530 Configuring Access Control Lists Figure 20-2. Add IP ACL 4 Click Apply. Removing IPv4 ACLs To delete an IPv4 ACL: 1 From the IP ACL Name menu on the IP ACL Configuration page, select the ACL to remove. 2 Select the Remove checkbox. 3 Click Apply. Viewing IPv4 ACLs To view configured ACLs, click Show All from the IP ACL Configuration page. Configuring Access Control Lists 531 Figure 20-3. View IPv4 ACLs IP ACL Rule Configuration Use the IP ACL Rule Configuration page to define rules for IP-based ACLs. The access list definition includes rules that specify whether traffic matching the criteria is forwarded normally or discarded. Additionally, you can specify to assign traffic to a particular queue, filter on some traffic, change VLAN tag, shut down a port, and/or redirect the traffic to a particular port. NOTE: There is an implicit deny all rule at the end of an ACL list. This means that if an ACL is applied to a packet and if none of the explicit rules match, then the final implicit "deny all" rule applies and the packet is dropped. To display the IP ACL Rule Configuration page, click Switching → Network Security → Access Control Lists → IP Access Control Lists → Rule Configuration in the navigation panel. 532 Configuring Access Control Lists Figure 20-4. IP ACL - Rule Configuration Removing an IP ACL Rule To delete an IP ACL rule: 1 From the Rule ID menu, select the ID of the rule to delete. 2 Select the Remove option near the bottom of the page. 3 Click Apply to remove the selected rule. Configuring Access Control Lists 533 MAC ACL Configuration Use the MAC ACL Configuration page to define a MAC-based ACL. To display the MAC ACL Configuration page, click Switching → Network Security → Access Control Lists → MAC Access Control Lists → Configuration in the navigation panel. Figure 20-5. MAC ACL Configuration Adding a MAC ACL To add a MAC ACL: 1 Open the MAC ACL Configuration page. 2 Click Add to display the Add MAC ACL page. 3 Specify an ACL name. 534 Configuring Access Control Lists Figure 20-6. Add MAC ACL 4 Click Apply. Renaming or Removing MAC ACLs To rename or delete a MAC ACL: 1 From the MAC ACL Name menu on the MAC ACL Configuration page, select the ACL to rename or remove. 2 To rename the ACL, select the Rename checkbox and enter a new name in the associated field. 3 To remove the ACL, select the Remove checkbox. 4 Click Apply. Viewing MAC ACLs To view configured ACLs, click Show All from the MAC ACL Configuration page. Configuring Access Control Lists 535 MAC ACL Rule Configuration Use the MAC ACL Rule Configuration page to define rules for MAC-based ACLs. The access list definition includes rules that specify whether traffic matching the criteria is forwarded normally or discarded. A default deny all rule is the last rule of every list. To display the MAC ACL Rule Configuration page, click Switching → Network Security → Access Control Lists → MAC Access Control Lists → Rule Configuration in the navigation panel. Figure 20-7. MAC ACL Rule Configuration Removing a MAC ACL Rule To delete a MAC ACL rule: 1 From the Rule ID menu, select the ID of the rule to delete. 2 Select the Remove option near the bottom of the page. 3 Click Apply to remove the selected rule. 536 Configuring Access Control Lists IPv6 ACL Configuration Use the IPv6 ACL Configuration page to add or remove IP-based ACLs. To display the IP ACL Configuration page, click Switching → Network Security → Access Control Lists → IPv6 Access Control Lists → IPv6 ACL Configuration in the navigation panel. Figure 20-8. IPv6 ACL Configuration Adding an IPv6 ACL To add an IPv6 ACL: 1 Open the IPv6 ACL Configuration page. 2 Click Add to display the Add IPv6 ACL page. 3 Specify an ACL name. Configuring Access Control Lists 537 Figure 20-9. Add IPv6 ACL 4 Click Apply. Removing IPv6 ACLs To delete an IPv6 ACL: 1 From the IPv6 ACL Name menu on the IPv6 ACL Configuration page, select the ACL to remove. 2 Select the Remove checkbox. 3 Click Apply. Viewing IPv6 ACLs To view configured ACLs, click Show All from the IPv6 ACL Configuration page. The IPv6 ACL Table page displays. IPv6 ACL Rule Configuration Use the IPv6 ACL Rule Configuration page to define rules for IPv6-based ACLs. The access list definition includes rules that specify whether traffic matching the criteria is forwarded normally or discarded. Additionally, you can specify to assign traffic to a particular queue, filter on some traffic, change VLAN tag, shut down a port, and/or redirect the traffic to a particular port. By default, no specific value is in effect for any of the IPv6 ACL rules. There is an implicit deny all rule at the end of an ACL list. This means that if an ACL is applied to a packet and if none of the explicit rules match, then the final implicit deny all rule applies and the packet is dropped. 538 Configuring Access Control Lists To display the IPv6 ACL Rule Configuration page, click Switching → Network Security → Access Control Lists → IPv6 Access Control Lists → Rule Configuration in the navigation menu. Figure 20-10. IPv6 ACL - Rule Configuration Removing an IPv6 ACL Rule To delete an IPv6 ACL rule: 1 From the Rule ID menu, select the ID of the rule to delete. 2 Select the Remove option near the bottom of the page. 3 Click Apply to remove the selected rule. Configuring Access Control Lists 539 ACL Binding Configuration When an ACL is bound to an interface, all the rules that have been defined are applied to the selected interface. Use the ACL Binding Configuration page to assign ACL lists to ACL Priorities and Interfaces. From the web interface, you can configure the ACL rule in the ingress or egress direction so that the ACLs implement security rules for packets entering or exiting the port. You can apply ACLs to any physical (including 10 Gb) interface, LAG, or routing port. To display the ACL Binding Configuration page, click Switching → Network Security → Access Control Lists → Binding Configuration in the navigation panel. Figure 20-11. 540 ACL Binding Configuration Configuring Access Control Lists Time Range Entry Configuration Use the Time Range Entry Configuration page to define time ranges to associate with ACL rules. To display the Time Range Entry Configuration page, click System → Time Synchronization → Time Range Configuration in the navigation panel. The following image shows the page after at least one time range has been added. Otherwise, the page indicates that no time ranges are configured, and the time range configuration fields are not displayed. Figure 20-12. Time Range Configuration Adding a Time Range To configure a time range: 1 From the Time Range Entry Configuration page, click Add. 2 Specify a name to identify the time range. Configuring Access Control Lists 541 Figure 20-13. Add a Time Range 3 Click Apply. 4 Click Configuration to return to the Time Range Entry Configuration page. 5 In the Time Range Name field, select the name of the time range to configure. 6 Specify an ID for the time range. You can configure up to 10 different time range entries to include in the named range. However, only one absolute time entry is allowed per time range. 7 Configure the values for the time range entry. 8 Click Apply. 9 To add additional entries to the named time range, repeat step 5 through step 8. 542 Configuring Access Control Lists Configuring ACLs (CLI) This section provides information about the commands you use to create and configure ACLs. For more information about the commands, see the PowerConnect 7000 Series CLI Reference Guide at support.dell.com/manuals. Configuring an IPv4 ACL Beginning in Privileged EXEC mode, use the following commands to create an IPv4 ACL, configure rules for the ACL, and bind the ACL to an interface. NOTE: The ip access-group command can be issued in Global Configuration mode or Interface configuration mode. If it is applied in Global Configuration mode, the ACL binding is applied to all interfaces. If it is applied in Interface Configuration mode, it is applied only to the specified interfaces within the mode. Command Purpose configure Enter global configuration mode. access-list name {deny | permit} {every | {[icmp | igmp | ip | tcp | udp | number] {srcip srcmask | any} [eq [portkey | portvalue]] {dstip dstmask | any} [eq [portkey | portvalue]] [precedence precedence | tos tos tosmask | dscp dscp] [log] [time-range time-range-name] [assign-queue queue-id] [redirect interface | mirror interface]}} Create a named ACL (if it does not already exist) and create a rule for the named ACL. If the ACL already exists, this command creates a new rule for the ACL. • list-name — Access-list name up to 31 characters in length. • deny | permit — Specifies whether the IP ACL rule permits or denies an action. • every — Allows all protocols. • eq — Equal. Refers to the Layer 4 port number being used as match criteria. The first reference is source match criteria, the second is destination match criteria. • number — Standard protocol number. Protocol keywords icmp, igmp, ip, tcp, udp. • srcip — Source IP address. • srcmask — Source IP mask. • dstip — Destination IP address. • dstmask — Destination IP mask. Configuring Access Control Lists 543 Command Purpose (continued) • portvalue — The source layer 4 port match condition for the ACL rule is specified by the port value parameter (Range: 0–65535). • portkey — Or you can specify the portkey, which can be one of the following keywords: domain, echo, ftp, ftpdata, http, smtp, snmp, telnet, tftp, and www. • log — Specifies that this rule is to be logged. • time-range-name — Specifies the named time range to associate with the ACL rule. • assign-queue queue-id — Specifies the particular hardware queue for handling traffic that matches the rule. (Range: 0-6) • mirror interface — Allows the traffic matching this rule to be copied to the specified interface. • redirect interface — This parameter allows the traffic matching this rule to be forwarded to the specified interface. interface interface (Optional) Enter interface configuration mode for the specified interface. The interface variable includes the interface type and number, for example gigabitethernet 1/0/3. You can also specify a range of interfaces with the interface range command, for example, interface range gigabitethernet 1/0/8-12 configures interfaces 8, 9, 10, 11, and 12. ip access-group name direction seqnum Bind the specified ACL to an interface. NOTE: To apply this ACL to all interfaces, issue the command in Global Configuration mode. • name — Access list name. (Range: Valid IP access-list name up to 31 characters in length) • direction — Direction of the ACL. (Range: In or out. Default is in.) • seqnum — Precedence for this interface and direction. A lower sequence number has higher precedence. Range: 1 – 4294967295. Default is1. 544 Configuring Access Control Lists Command Purpose CTRL + Z Exit to Privileged EXEC mode. show ip access-lists [name] Display all IPv4 access lists and all of the rules that are defined for the IPv4 ACL. Use the optional name parameter to identify a specific IPv4 ACL to display. Configuring a MAC ACL Beginning in Privileged EXEC mode, use the following commands to create an MAC ACL, configure rules for the ACL, and bind the ACL to an interface. Command Purpose configure Enter global configuration mode. mac access-list extended Create a named MAC ACL. This command also enters name MAC Access List Configuration mode. If a MAC ACL with this name already exists, this command enters the mode to update the existing ACL. {deny | permit} {srcmac srcmacmask | any} {dstmac dstmacmask | any | bpdu } [{ethertypekey | 0x0600-0xFFFF }] [vlan eq 0-4095 ] [cos 0-7] [secondary-vlan eq 04095 ] [secondary-cos 0-7] [log] [time-range time-range-name] [assign-queue queue-id] [{mirror |redirect} interface ] Specify the rules (match conditions) for the MAC access list. • srcmac — Valid source MAC address in format xxxx.xxxx.xxxx. • srcmacmask — Valid MAC address bitmask for the source MAC address in format xxxx.xxxx.xxxx. • any — Packets sent to or received from any MAC address • dstmac — Valid destination MAC address in format xxxx.xxxx.xxxx. • destmacmask — Valid MAC address bitmask for the destination MAC address in format xxxx.xxxx.xxxx. • bpdu — Bridge protocol data unit • ethertypekey — Either a keyword or valid four-digit hexadecimal number. (Range: Supported values are appletalk, arp, ibmsna, ipv4, ipv6, ipx, mplsmcast, mplsucast, Netbios, novell, pppoe, rarp.) • 0x0600-0xFFFF — Specify custom EtherType value (hexadecimal range 0x0600-0xFFFF) Configuring Access Control Lists 545 Command Purpose (Continued) • vlan eq — VLAN number. (Range 0-4095) • cos — Class of service. (Range 0-7) • log — Specifies that this rule is to be logged. • time-range-name — Specifies the named time range to associate with the ACL rule. • assign-queue — Specifies particular hardware queue for handling traffic that matches the rule. • queue-id — 0-6, where n is number of user configurable queues available for that hardware platform. • mirror interface — Allows the traffic matching this rule to be copied to the specified interface. • redirect interface — This parameter allows the traffic matching this rule to be forwarded to the specified interface. interface interface (Optional) Enter interface configuration mode for the specified interface. The interface variable includes the interface type and number, for example gigabitethernet 1/0/3. You can also specify a range of interfaces with the interface range command, for example, interface range gigabitethernet 1/0/8-12 configures interfaces 8, 9, 10, 11, and 12. mac access-group name direction seqnum Bind the specified MAC ACL to an interface. NOTE: To apply this ACL to all interfaces, issue the command in Global Configuration mode. • name — Access list name. (Range: Valid MAC access-list name up to 31 characters in length) • direction — Direction of the ACL. (Range: In or out. Default is in.) • seqnum — Precedence for this interface and direction. A lower sequence number has higher precedence. Range: 1 – 4294967295. Default is1. CTRL + Z 546 Exit to Privileged EXEC mode. Configuring Access Control Lists Command Purpose show mac access-lists [name] Display all MAC access lists and all of the rules that are defined for the MAC ACL. Use the optional name parameter to identify a specific MAC ACL to display. Configuring an IPv6 ACL Beginning in Privileged EXEC mode, use the following commands to create an IPv6 ACL, configure rules for the ACL, and bind the ACL to an interface. Command Purpose configure Enter global configuration mode. ipv6 access-list name Create a named IPv6 ACL. This command also enters IPv6 Access List Configuration mode. If an IPv6 ACL with this name already exists, this command enters the mode to update the existing ACL. {permit | deny} {every | {{icmp | igmp | ipv6 | tcp | udp | number} {any | source ipv6 prefix/prefix length} [eq {portkey | portvalue}] {any | destination ipv6 prefix/prefix length} [eq {portkey | portvalue}] [flow-label value] [dscp dscp]}} [log] [timerange time-range-name] [assign-queue queue-id] [{mirror | redirect} interface] Specify the match conditions for the IPv6 access list. • deny | permit — Specifies whether the IP ACL rule permits or denies an action. • every — Allows all protocols. • number — Standard protocol number or protocol keywords icmp, igmp, ipv6, tcp, udp. • source ipv6 prefix — IPv6 prefix in IPv6 global address format. • prefix-length — IPv6 prefix length value. • eq — Equal. Refers to the Layer 4 port number being used as a match criteria. The first reference is source match criteria, the second is destination match criteria. • portkey — Or you can specify the portkey, which can be one of the following keywords: domain, echo, efts, ftpdata, http, smtp, snmp, telnet, tftp, and www. • portvalue — The source layer 4 port match condition for the ACL rule is specified by the port value parameter. (Range: 0–65535). Configuring Access Control Lists 547 Command Purpose (Continued) • destination ipv6 prefix — IPv6 prefix in IPv6 global address format. • flow label value — The value to match in the Flow Label field of the IPv6 header (Range 0–1048575). • dscp dscp — Specifies the TOS for an IPv6 ACL rule depending on a match of DSCP values using the parameter dscp. • log — Specifies that this rule is to be logged. • time-range-name — Specifies the named time range to associate with the ACL rule. • assign-queue queue-id — Specifies particular hardware queue for handling traffic that matches the rule. • mirror interface — Allows the traffic matching this rule to be copied to the specified interface. • redirect interface — This parameter allows the traffic matching this rule to be forwarded to the specified interface. interface interface (Optional) Enter interface configuration mode for the specified interface. The interface variable includes the interface type and number, for example gigabitethernet 1/0/3. You can also specify a range of interfaces with the interface range command, for example, interface range gigabitethernet 1/0/8-12 configures interfaces 8, 9, 10, 11, and 12. ipv6 traffic-filter name Bind the specified IPv6 ACL to an interface. direction [sequence seq- NOTE: To apply this ACL to all interfaces, issue the command num] in Global Configuration mode. • name — Access list name. (Range: Valid IPv6 access-list name up to 31 characters in length) • direction — Direction of the ACL. (Range: In or out. Default is in.) • seqnum — Precedence for this interface and direction. A lower sequence number has higher precedence. Range: 1 – 4294967295. Default is1. 548 Configuring Access Control Lists Command Purpose CTRL + Z Exit to Privileged EXEC mode. show ipv6 access-lists [name] Display all IPv6 access lists and all of the rules that are defined for the IPv6 ACL. Use the optional name parameter to identify a specific IPv6 ACL to display. Configuring a Time Range Beginning in Privileged EXEC mode, use the following commands to create a time range and configure time-based entries for the time range. Command Purpose configure Enter global configuration mode. time-range name Create a named time range and enter the Time-Range Configuration mode for the range. absolute {[start time date] [end time date ]} Configure a nonrecurring time entry for the named time range. • start time date — Time and date the ACL rule starts going into effect. The time is expressed in a 24-hour clock, in the form of hours:minutes. For example, 8:00 is 8:00 am and 20:00 is 8:00 pm. The date is expressed in the format day month year. If no start time and date are specified, the configuration statement is in effect immediately. • end time date — Time and date the ACL rule is no longer in effect. Configuring Access Control Lists 549 Command Purpose periodic {days-of-theConfigure a recurring time entry for the named time week time} to {[days-of- range. the-week ] time} • days-of-the-week —The first occurrence indicates the starting day(s) the ACL goes into effect. The second occurrence is the ending day(s) when the ACL rule is no longer in effect. If the end days-of-the-week are the same as the start, they can be omitted This variable can be any single day or combinations of days: Monday, Tuesday, Wednesday, Thursday, Friday, Saturday, Sunday. Other possible values are: – daily -- Monday through Sunday – weekdays -- Monday through Friday – weekend -- Saturday and Sunday • time — Time the ACL rule starts going into effect (first occurrence) or ends (second occurrence). The time is expressed in a 24-hour clock, in the form of hours:minutes. CTRL + Z Exit to Privileged EXEC mode. show time-range [name] View information about all configured time ranges, including the absolute/periodic time entries that are defined for each time range. Use the name variable to view information about the specified time range. 550 Configuring Access Control Lists ACL Configuration Examples This section contains the following examples: • Configuring an IP ACL • Configuring a MAC ACL • Configuring a Time-Based ACL • Configuring a Management Access List Configuring an IP ACL The commands in this example set up an IP ACL that permits hosts in the 192.168.77.0/24 subnet to send TCP and UDP traffic only to the host with an IP address of 192.168.77.50. The ACL is applied to port 2 on the PowerConnect switch. Configuring Access Control Lists 551 Figure 20-14. IP ACL Example Network Diagram PowerConnect Switch (Layer 3) Port Gi 1/0/2 UDP or TCP packet to 192.168.88.50 rejected: Dest. IP not in range. 192.168.77.1 Layer 2 Switch 192.168.77.2 192.168.77.3 UDP or TCP packet to 192.168.77.50 permitted: Dest. IP in range. 192.168.77.4 To configure the switch: 1 Create an ACL named list1 and configures a rule for the ACL that permits packets carrying TCP traffic that matches the specified Source IP address (192.168.77.0/24), and sends these packets to the specified Destination IP address (192.168.77.50). console#config console(config)#access-list list1 permit tcp 192.168.77.0 0.0.0.255 192.168.77.50 0.0.0.0 2 Define the rule to set similar conditions for UDP traffic as for TCP traffic. console(config)#access-list list1 permit udp 192.168.77.0 0.0.0.255 192.168.77.3 0.0.0.255 console(config)#exit 552 Configuring Access Control Lists 3 Apply the rule to inbound (ingress) traffic on Gigabit Ethernet Port 2. Only traffic matching the criteria will be accepted on this port. console(config)#interface gi1/0/2 console(config-if-Gi1/0/2)#ip access-group list1 in console(config-if-Gi11/0/2)#exit Configuring a MAC ACL The following example creates a MAC ACL named mac1 that denies all IPX traffic on all ports. All other type of traffic is permitted. To configure the switch: 1 Create a MAC Access List named mac1 console#config console(config)#mac access-list extended mac1 2 Configure a rule to deny all IPX traffic, regardless of the source or destination MAC address. console(config-mac-access-list)#deny any any ipx 3 Configure a rule to permit all other types of traffic, regardless of the source or destination MAC address. console(config-mac-access-list)#permit any any console(config-mac-access-list)#exit 4 Bind the ACL to all ports. console(config)#mac access-group mac1 in console(config)#exit 5 View information about the configured ACL. console#show mac access-lists Current number of all ACLs: 1 all ACLs: 100 MAC ACL Name Rules ------------- -------- Maximum number of Interface(s) Direction ------------ --------- Configuring Access Control Lists 553 mac1 2 ch1-48, Gi1/0/1Gi1/0/48 Inbound console#show mac access-lists mac1 MAC ACL Name: mac1 Inbound Interface(s): ch1-48,Gi1/0/1-Gi1/0/48 Rule Number: 1 Action.................................. deny Ethertype................................ ipx Rule Number: 2 Action.................................. permit Match All............................... TRUE 554 Configuring Access Control Lists Configuring a Time-Based ACL The following example configures an ACL that denies HTTP traffic from 8:00 pm to 12:00 pm and 1:00 pm to 6:00 pm on weekdays and from 8:30 am to 12:30 pm on weekends. The ACL affects all hosts connected to ports that are members of VLAN 100. The ACL permits VLAN 100 members to browse the Internet only during lunch and after hours. To configure the switch: 1 Create a time range called work-hours. console#config console(config)#time-range work-hours 2 Configure an entry for the time range that applies to the morning shift Monday through Friday. console(config-time-range)#periodic weekdays 8:00 to 12:00 3 Configure an entry for the time range that applies to the afternoon shift Monday through Friday. console(config-time-range)#periodic weekdays 13:00 to 18:00 4 Configure an entry for the time range that applies to Saturday and Sunday. console(config-time-range)#periodic weekend 8:30 to 12:30 console(config-time-range)#exit 5 Create an ACL named web-limit that denies HTTP traffic during the work-hours time range. console(config)#access-list web-limit deny tcp any any eq http time-range work-hours 6 Enter interface configuration mode for VLAN 100 and apply the ACL to ingress traffic. console(config)#interface vlan 100 console(config-if-vlan100)#ip access-group weblimit in console(config-if-vlan100)#exit console(config)#exit Configuring Access Control Lists 555 7 Verify the configuration. console#show ip access-lists web-limit IP ACL Name: web-limit Inbound VLAN(s): 100 Rule Number: 1 Action............................ deny Match All......................... FALSE Protocol.......................... 6(tcp) Source IP Address................. any Destination IP Address............ any Destination L4 Port Keyword........ 80(www/http)ip Time Range Name....................work-hours Rule Status....................... inactive Configuring a Management Access List You can create a management access list that contains rules to apply to one or more in-band ports, LAGs, or VLANs to limit management access by method (for example, Telnet or HTTP) and/or source IP address. NOTE: Management ACLs cannot be applied to the OOB port. NOTE: Management ACLs can be applied only to in-band ports and cannot be applied to the OOB port. Management Access List Commands Beginning in Privileged EXEC mode, use the following commands to create a management access list. There is an implicit deny-all rule at the end of every management ACL. This means that any host that does not meet the criteria defined in a permit command is denied access to the management interface. Command Purpose configure Enter Global Configuration mode. 556 Configuring Access Control Lists Command Purpose management access-list Define an access list for management, and enter the access-list for configuration. permit ip-source ipaddress [mask mask | prefix-length] [interfacetype interface-number] [service service] [priority priority-value] Allow access to the management interface from hosts that meet the specified IP address value and other optional criteria. name • interface-type interface-number — A valid port, LAG, or VLAN interface, for example gi1/0/13, port-channel 3, or vlan 200. • ip-address — Source IP address. • mask mask — Specifies the network mask of the source IP address. • mask prefix-length — Specifies the number of bits that comprise the source IP address prefix. The prefix length must be preceded by a forward slash (/). (Range: 0–32) • service service — Indicates service type. Can be one of the following: telnet, ssh, http, https, tftp, snmp, sntp, or any. • priority priority-value — Priority for the rule. (Range: 1 – 64) Permit access to the management interface from the permit {interface-type specified port, VLAN, or LAG and meet the other optional interface-number} [service service] [priority criteria. priority-value] permit service service [priority priority-value] Permit access to the management interface from the specified service. exit Exit to Global Configuration mode. management accessclass {console-only | name} Activate the management ACL or restrict access so that it is available only through the console port. exit Exit to Privileged EXEC mode. show management access-class Display information about the active management access list. show management access-list [name] Display information about the configured management ACL and its rules. Configuring Access Control Lists 557 Management Access List Example The commands in this example create a management ACL that permits access to the switch through the in-band switch ports on VLAN 1 and on port 9 from hosts with an IP address in the 10.27.65.0 subnet. Attempts to access the management interfaces from any other hosts and on any other interfaces is denied. To configure the switch: 1 Create a management ACL and enter the configuration mode for the ACL. console#configure console(config)#management access-list mgmt_ACL 2 Create a rule that allows access from hosts in the 10.27.65.0 network on VLAN 1 and assign a priority of 1 to the rule. console(config-macl)#permit ip-source 10.27.65.0 mask 255.255.255.0 vlan 1 priority 1 3 Create a rule that allows access from hosts in the 10.27.65.0 network on connected to port 9 and assign a priority of 2 to the rule. console(config-macl)#permit ip-source 10.27.65.0 mask 255.255.255.0 Gi1/0/9 priority 2 console(config-macl)#exit 4 Activate the ACL. console(config)#management access-class mgmt_ACL console(config)#exit 5 Verify the management ACL configuration. console#show management access-list mgmt_ACL -------permit ip-source 10.27.65.0 mask 255.255.255.0 vlan 1 priority 1 permit ip-source 10.27.65.0 mask 255.255.255.0 Gi1/0/9 priority 2 ! (Note: all other access implicitly denied) 6 Verify that the configured management ACL is in use. 558 Configuring Access Control Lists console#show management access-class Management access-class is enabled, using access list mgmt_ACL. Configuring Access Control Lists 559 560 Configuring Access Control Lists Configuring VLANs 21 This chapter describes how to configure VLANs, including port-based VLANs, protocol-based VLANs, double-tagged VLANs, subnet-based VLANs, and Voice VLANs. The topics covered in this chapter include: • VLAN Overview • Default VLAN Behavior • Configuring VLANs (Web) • Configuring VLANs (CLI) • VLAN Configuration Examples VLAN Overview By default, all switchports on a PowerConnect 7000 Series switch are in the same broadcast domain. This means when one host connected to the switch broadcasts traffic, every device connected to the switch receives that broadcast. All ports in a broadcast domain also forward multicast and unknown unicast traffic to the connected host. Large broadcast domains can result in network congestion, and end users might complain that the network is slow. In addition to latency, large broadcast domains are a greater security risk since all hosts receive all broadcasts. Virtual Local Area Networks (VLANs) allow you to divide a broadcast domain into smaller, logical networks. Like a bridge, a VLAN switch forwards traffic based on the Layer 2 header, which is fast, and like a router, it partitions the network into logical segments, which provides better administration, security, and management of multicast traffic. Network administrators have many reasons for creating logical divisions, such as department or project membership. Because VLANs enable logical groupings, members do not need to be physically connected to the same switch or network segment. Some network administrators use VLANs to segregate traffic by type so that the time-sensitive traffic, like voice traffic, has Configuring VLANs 561 priority over other traffic, such as data. Administrators also use VLANs to protect network resources. Traffic sent by authenticated clients might be assigned to one VLAN, while traffic sent from unauthenticated clients might be assigned to a different VLAN that allows limited network access. When one host in a VLAN sends a broadcast, the switch forwards traffic only to other members of that VLAN. For traffic to go from a host in one VLAN to a host in a different VLAN, the traffic must be forwarded by a layer 3 device, such as a router. VLANs work across multiple switches and switch stacks, so there is no requirement for the hosts to be located near each other to participate in the same VLAN. NOTE: PowerConnect 7000 Series switches support VLAN routing. When you configure VLAN routing, the switch acts as a layer 3 device and can forward traffic between VLANs. For more information, see "What Are VLAN Routing Interfaces?" on page 843. Each VLAN has a unique number, called the VLAN ID. The PowerConnect 7000 Series switches support a configurable VLAN ID range of 2–4093. A VLAN with VLAN ID 1 is configured on the switch by default. VLAN 1 is named default, which cannot be changed. However, you can associate names with any other VLANs that you create. In a tagged frame, the VLAN is identified by the VLAN ID in the tag. In an untagged frame, the VLAN identifier is the Port VLAN ID (PVID) specified for the port that received the frame. For information about tagged and untagged frames, see "VLAN Tagging" on page 565. The PowerConnect 7000 Series switches support adding individual ports and Link Aggregation Groups (LAGs) as VLAN members. Figure 21-1 shows an example of a network with three VLANs that are department-based. The file server and end stations for the department are all members of the same VLAN. 562 Configuring VLANs Figure 21-1. Simple VLAN Topology Router Engineering VLAN 100 Switch Payroll VLAN 300 Tech Pubs VLAN 200 In this example, each port is manually configured so that the end station attached to the port is a member of the VLAN configured for the port. The VLAN membership for this network is port-based or static. PowerConnect 7000 Series switches also support VLAN assignment based on any of the following criteria: • MAC address of the end station • IP subnet of the end station • Protocol of the packet transmitted by the end station Configuring VLANs 563 Table 21-1 provides an overview of the types of VLANs you can use to logically divide the network. Table 21-1. VLAN Assignment VLAN Assignment Description Port-based (Static) This is the most common way to assign hosts to VLANs. The port where the traffic enters the switch determines the VLAN membership. IP Subnet Hosts are assigned to a VLAN based on their IP address. All hosts in the same subnet are members of the same VLAN. MAC-Based The MAC address of the device determines the VLAN assignment. This type of VLAN is useful when a host might not always connect to the network through the same port but needs to be on the same VLAN. Protocol Protocol-based VLANs were developed to separate traffic based on the protocol type before IP traffic became the de facto standard in the LAN. Use a protocol-based VLAN on networks where you might have a group of hosts that use IPX or another legacy protocol. With protocol-based VLANs, you can segregate traffic based on the EtherType value in the frame. Switchport Modes You can configure each port on a PowerConnect 7000 Series switch to be in one of the following modes: 564 • Access — Access ports are intended to connect end-stations to the system, especially when the end-stations are incapable of generating VLAN tags. Access ports support a single VLAN (the PVID). Packets received untagged are processed as if they are tagged with the access port PVID. Packets received that are tagged with the PVID are also processed. Packets received that are tagged with a VLAN other than the PVID are dropped. • Trunk — Trunk-mode ports are intended for switch-to-switch links. Trunk ports can receive both tagged and untagged packets. Tagged packets received on a trunk port are forwarded on the VLAN contained in the tag. Untagged packets received on a trunk port are forwarded on the native VLAN. Packets received on another interface belonging to the native VLAN are transmitted untagged on a trunk port. Configuring VLANs • General — General ports can act like access or trunk ports or a hybrid of both. VLAN membership rules that apply to a port are based on the switchport mode configured for the port. Table 21-2 shows the behavior of the three switchport modes. Table 21-2. Switchport Mode Behavior Mode VLAN Membership Frames Accepted Frames Sent Ingress Filtering Access One VLAN Untagged Untagged Always On Trunk All VLANs that exist in the system Tagged Tagged Always On General As many as desired Tagged or Untagged Tagged or Untagged On or Off When a port is in General mode, all VLAN features are configurable. When ingress filtering is on, the frame is dropped if the port is not a member of the VLAN identified by the VLAN ID in the tag. If ingress filtering is off, all tagged frames are forwarded. The port decides whether to forward or drop the frame when the port receives the frame. VLAN Tagging PowerConnect 7000 Series switches support IEEE 802.1Q tagging. Ethernet frames on a tagged VLAN have a 4-byte VLAN tag in the header. VLAN tagging is required when a VLAN spans multiple switches, which is why trunk ports transmit and receive only tagged frames. NOTE: A stack of switches behaves as a single switch, so VLAN tagging is not required for packets traversing different stack members. Tagging may be required when a single port supports multiple devices that are members of different VLANs. For example, a single port might be connected to an IP phone, a PC, and a printer (the PC and printer are connected via ports on the IP phone). IP phones are typically configured to use a tagged VLAN for voice traffic, while the PC and printers typically use the untagged VLAN. Configuring VLANs 565 Trunk ports can receive tagged and untagged traffic. Untagged traffic is tagged internally with the native VLAN. Native VLAN traffic received untagged is transmitted untagged on a trunk port. By default, trunk ports are members of all existing VLANs and will automatically participate in any newly created VLANs. The administrator can restrict the VLAN membership of a trunk port. VLAN membership for tagged frames received on a trunk port is configured separately from the membership of the native VLAN. To configure a trunk port to accept frames only for a single VLAN, both the native VLAN and the tagged VLAN membership settings must be configured. Access ports accept untagged traffic and traffic tagged with the access port PVID. Untagged ingress traffic is considered to belong to the VLAN identified by the PVID. GVRP The GARP VLAN Registration Protocol (GVRP) helps to dynamically manage VLAN memberships on trunk ports. When GARP is enabled, switches can dynamically register (and de-register) VLAN membership information with other switches attached to the same segment. Information about the active VLANs is propagated across all networking switches in the bridged LAN that support GVRP. You can configure ports to forbid dynamic VLAN assignment through GVRP. The operation of GVRP relies upon the services provided by the Generic Attribute Registration Protocol (GARP). GVRP can create up to 1024 VLANs. For information about GARP timers, see "What Are GARP and GMRP?" on page 709. Double-VLAN Tagging For trunk ports, which are ports that connect one switch to another switch, the PowerConnect 7000 Series switches support double-VLAN tagging. This feature allows service providers to create Virtual Metropolitan Area Networks (VMANs). With double-VLAN tagging, service providers can pass VLAN traffic from one customer domain to another through a metro core in a simple and cost-effective manner. By using an additional tag on the traffic, 566 Configuring VLANs the switch can differentiate between customers in the MAN while preserving an individual customer’s VLAN identification when the traffic enters the customer’s 802.1Q domain. With the introduction of this second tag, customers are no longer required to divide the 4-byte VLAN ID space to send traffic on a Ethernet-based MAN. In short, every frame that is transmitted from an interface has a double-VLAN tag attached, while every packet that is received from an interface has a tag removed (if one or more tags are present). In Figure 21-2, two customers share the same metro core. The service provider assigns each customer a unique ID so that the provider can distinguish between the two customers and apply different rules to each. When the configurable EtherType is assigned to something different than the 802.1Q (0x8100) EtherType, it allows the traffic to have added security from misconfiguration while exiting the metro core. For example, if the edge device on the other side of the metro core is not stripping the second tag, the packet would never be classified as a 802.1Q tag, so the packet would be dropped rather than forwarded in the incorrect VLAN. Configuring VLANs 567 Figure 21-2. Double VLAN Tagging Network Example Voice VLAN The Voice VLAN feature enables switch ports to carry voice traffic with defined priority. When multiple devices, such as a PC and an IP phone, are connected to the same port, you can configure the port to use one VLAN for voice traffic and another VLAN for data traffic. Voice over IP (VoIP) traffic is inherently time-sensitive: for a network to provide acceptable service, the transmission rate is vital. The priority level enables the separation of voice and data traffic coming onto the port. A primary benefit of using Voice VLAN is to ensure that the sound quality of an IP phone is safeguarded from deteriorating when the data traffic on the port is high. The switch uses the source MAC address of the traffic traveling through the port to identify the IP phone data flow. The Voice VLAN feature can be enabled on a per-port basis. This feature supports a configurable voice VLAN DSCP value. This value is later retrieved by LLDP when the LLDPDU is transmitted, if LLDP has been enabled on the port and the required TLV is configured for the port. 568 Configuring VLANs Identifying Voice Traffic Some VoIP phones contain full support for IEEE 802.1X. When these phones are connected to a port that uses 802.1X port-based authentication, these phones authenticate and receive their VLAN information from LLDP-MED. However, if a VoIP phone has limited support for 802.1X authentication it might try to authenticate and fail. A phone with no 802.1X support would not attempt to authenticate at all. Instead of placing these phones on an unauthenticated or guest VLAN, the switch can automatically direct the VoIP traffic to the Voice VLAN without manual configuration. The switch identifies the device as a VoIP phone by one of the following protocols: • Cisco Discovery Protocol (CDP) or Industry Standard Discovery Protocol (ISDP) for Cisco VoIP phones • DHCP vendor-specific options for Avaya VoIP phones • LLDP-MED for most VoIP phones NOTE: By default, ISDP is enabled globally and per-interface on the switch. LLDP-MED is disabled on each interface by default. Port-based authentication using 802.1X is also disabled on each port by default. After the VoIP phone receives its VLAN information, all traffic is tagged with the VLAN ID of the Voice VLAN. The phone is considered to be authorized to send traffic but not necessarily authenticated. Segregating Traffic with the Voice VLAN You can configure the switch to support Voice VLAN on a port that is connecting the VoIP phone. Both of the following methods segregate the voice traffic and the data traffic in order to provide better service to the voice traffic. • When a VLAN is associated with the Voice VLAN port, then the VLAN ID information is passed onto the VoIP phone using either the LLDP-MED or the CPD mechanism, depending on how the phone is identified: if it is identified via CDP, then the VLAN assignment is via CDP and if it is identified via LLDP-MED, then the VLAN assignment is via LLDP-MED. By this method, the voice data coming from the VoIP phone is tagged with the exchanged VLAN ID. Untagged data arriving on the switch is given the Configuring VLANs 569 default PVID of the port, and the voice traffic is received tagged with the predefined VLAN. As a result, both kinds of traffic are segregated in order to provide better service to the voice traffic. • When a dot1p priority is associated with the Voice VLAN port instead of a VLAN ID, then the priority information is passed onto the VoIP phone using the LLDP-MED or CDP mechanism. By this method, the voice data coming from the VoIP phone is tagged with VLAN 0 and with the exchanged priority; thus regular data arriving on the switch is given the default priority of the port (default 0), and the voice traffic is received with a higher priority. You can configure the switch to override the data traffic CoS. This feature can override the 802.1 priority of the data traffic packets arriving at the port enabled for Voice VLAN. Therefore, any rogue client that is also connected to the Voice VLAN port does not deteriorate the voice traffic. Voice VLAN and LLDP-MED The interactions with LLDP-MED are important for Voice VLAN: • LLDP-MED notifies the Voice VLAN component of the presence and absence of a VoIP phone on the network. • The Voice VLAN component interacts with LLDP-MED for applying VLAN ID, priority, and tag information to the VoIP phone traffic. Private VLANs Private VLANs partition a standard VLAN domain into two or more subdomains. Each subdomain is defined by a primary VLAN and a secondary VLAN. The primary VLAN ID is the same for all subdomains that belong to a particular private VLAN instance. The secondary VLAN ID differentiates the subdomains from each other and provides layer 2 isolation between ports on the same private VLAN. The following types of VLANs can be configured in a private VLAN: • 570 Primary VLAN—Forwards the traffic from the promiscuous ports to isolated ports, community ports and other promiscuous ports in the same private VLAN. Only one primary VLAN can be configured per private VLAN. All ports within a private VLAN share the same primary VLAN. Configuring VLANs • Isolated VLAN—A secondary VLAN. It carries traffic from isolated ports to promiscuous ports. Only one isolated VLAN can be configured per private VLAN. • Community VLAN—A secondary VLAN. It forwards traffic between ports which belong to the same community and to the promiscuous ports. There can be multiple community VLANs per private VLAN. A port may be designated as one of the following types in a private VLAN: • Promiscuous port—A port associated with a primary VLAN that is able to communicate with all interfaces in the private VLAN, including other promiscuous ports, community ports and isolated ports. • Host port—A port associated with a secondary VLAN that can either communicate with the promiscuous ports in the VLAN and with other ports in the same community (if the secondary VLAN is a community VLAN) or can communicate only with the promiscuous ports (if the secondary VLAN is an isolated VLAN). Private VLANs may be configured across a stack and on physical and portchannel interfaces. Private VLAN Usage Scenarios Private VLANs are typically implemented in a DMZ for security reasons. Servers in a DMZ are generally not allowed to communicate with each other but they must communicate to a router, through which they are connected to the users. Such servers are connected to host ports, and the routers are attached to promiscuous ports. Then, if one of the servers is compromised, the intruder cannot use it to attack another server in the same network segment. The same traffic isolation can be achieved by assigning each port with a different VLAN, allocating an IP subnet for each VLAN, and enabling layer 3 routing between them. In a private VLAN domain, on the other hand, all members can share the common address space of a single subnet, which is associated with a primary VLAN. So, the advantage of the private VLANs feature is that it reduces the number of consumed VLANs, improves IP addressing space utilization, and helps to avoid layer 3 routing. Configuring VLANs 571 Figure 21-3 shows an example Private VLAN scenario, in which five hosts (HA through H-E) are connected to a stack of switches (SW1, SW2). The switch stack is connected to router R1. Port references shown are with reference to the stack. Figure 21-3. Private VLAN Domain R1 TE1/1/1 SW1 Gi1/0/10 H-A SW2 Gi1/0/12 Gi1/0/11 H-B H-C Gi2/0/10 H-D Gi2/0/11 H-E Promiscuous Ports An endpoint connected to a promiscuous port is allowed to communicate with any endpoint within the private VLAN. Multiple promiscuous ports can be defined for a single private VLAN domain. In the configuration shown in Figure 21-3, the port connected from SW1 to R1 (TE1/1/1) is configured as a promiscuous port. It is possible to configure a port-channel as a promiscuous port in order to provide a level of redundancy on the private VLAN uplink. 572 Configuring VLANs Isolated Ports An endpoint connected to an isolated port is allowed to communicate with endpoints connected to promiscuous ports only. Endpoints connected to adjacent isolated ports cannot communicate with each other. Community Ports An endpoint connected to a community port is allowed to communicate with the endpoints within a community and can also communicate with any configured promiscuous port. The endpoints that belong to one community cannot communicate with endpoints that belong to a different community, or with endpoints connected to isolated ports. Private VLAN Operation in the Switch Stack and Inter-switch Environment The Private VLAN feature is supported in a stacked switch environment. The stack links are transparent to the configured VLANs; thus, there is no need for special private VLAN configuration beyond what would be configured for a single switch. Any private VLAN port can reside on any stack member. To enable private VLAN operation across multiple switches that are not stacked, trunk ports must be configured between the switches to transport the private VLANs. The trunk ports must be configured with the promiscuous, isolated, and community VLANs. Trunk ports must also be configured on all devices separating the switches. In regular VLANs, ports in the same VLAN switch traffic at L2. However, for a private VLAN, the promiscuous port forwards received traffic to secondary ports in the VLAN (isolated and community). Community ports forward received traffic to the promiscuous ports and other community ports using the same secondary VLAN. Isolated ports transmit received traffic to the promiscuous ports only. The ports to which the broadcast traffic is forwarded depend on the type of port on which the traffic was received. If the received port is a host port, traffic is broadcast to all promiscuous and trunk ports. If the received port is a community port, the broadcast traffic is forwarded to all promiscuous, trunk, and community ports in the same secondary VLAN. A promiscuous port broadcasts traffic to other promiscuous ports, isolated ports, and community ports. Configuring VLANs 573 Table 21-3. Forwarding Rules for Traffic in Primary VLAN To From promiscuous community 1 community 2 isolated stack (trunk) promiscuous allow allow allow allow allow community 1 N/A N/A N/A N/A N/A community 2 N/A N/A N/A N/A N/A isolated N/A N/A N/A N/A N/A stack (trunk) allow allow allow allow allow Table 21-4. Forwarding Rules for Traffic in Community 1 VLAN To From promiscuous community 1 community 2 isolated stack (trunk) promiscuous N/A N/A N/A N/A N/A community 1 allow allow deny deny allow community 2 N/A N/A N/A N/A N/A isolated N/A N/A N/A N/A N/A stack (trunk) allow allow deny deny allow Table 21-5. Forwarding Rules for Traffic in Isolated VLAN To 574 From promiscuous community 1 community 2 isolated stack (trunk) promiscuous N/A N/A N/A N/A N/A community 1 N/A N/A N/A N/A N/A community 2 N/A N/A N/A N/A N/A isolated allow deny deny deny allow stack (trunk) allow deny deny deny Allow Configuring VLANs Limitations and Recommendations • Only a single isolated VLAN can be associated with a primary VLAN. Multiple community VLANs can be associated with a primary VLAN. • Trunk and general modes are not supported on private VLAN ports. • Do not configure access ports using the VLANs participating in any of the private VLANs. • Multiple primary VLANs may be configured. Each primary VLAN must be unique and each defines a separate private VLAN domain. The operator must take care to use only the secondary VLANs associated with the primary VLAN of a domain. • Private VLANs cannot be enabled on a preconfigured interface. The interface must physically exist in the switch. • Secondary (community and isolated) VLANS are associated to the same multiple spanning tree instance as the primary VLAN. • GVRP/MVRP cannot be enabled after the private VLAN is configured. The administrator will need to disable both before configuring the private VLAN. • DHCP snooping can be configured on the primary VLAN. If it is enabled for a secondary VLAN, the configuration does not take effect if a primary VLAN is already configured. • If IP source guard is enabled on private VLAN ports, then DHCP snooping must be enabled on the primary VLAN. • Do not configure private VLAN ports on interfaces configured for voice VLAN. • If static MAC addresses are added for the host port, the same static MAC address entry must be added to the associated primary VLAN. This does not need to be replicated for dynamic MAC addresses. • A private VLAN cannot be enabled on a management VLAN. • A private VLAN cannot be enabled on the default VLAN. • VLAN routing can be enabled on private VLANs. It is not very useful to enable routing on secondary VLANs, as the access to them is restricted. However, primary VLANs can be enabled for routing. Configuring VLANs 575 • It is recommended that the private VLAN IDs be removed from the trunk ports connected to devices that do not participate in the private VLAN traffic. Private VLAN Configuration Example See "Configuring a Private VLAN" on page 626. Additional VLAN Features The PowerConnect 7000 Series switches also support the following VLANs and VLAN-related features: 576 • VLAN routing interfaces — See "Configuring Routing Interfaces" on page 843. • Guest VLAN — See "Configuring Port and System Security" on page 481. Configuring VLANs Default VLAN Behavior One VLAN is configured on the PowerConnect 7000 Series switches by default. The VLAN ID is 1, and all ports are included in the VLAN as access ports, which are untagged. This means when a device connects to any port on the switch, the port forwards the packets without inserting a VLAN tag. If a device sends a tagged frame to a port with a VLAN ID other than 1, the frame is dropped. Since all ports are members of this VLAN, all ports are in the same broadcast domain and receive all broadcast and multicast traffic received on any port. When you create a new VLAN, all trunk ports are members of the VLAN by default. The configurable VLAN range is 2–4093. VLANs 4094 and 4095 are reserved. Ports in trunk and access mode have the default behavior shown in Table 21-2 and cannot be configured with different tagging or ingress filtering values. When you add a VLAN to a port in general mode, the VLAN has the behavior shown in Table 21-6. Table 21-6. General mode Default Settings Feature Default Value Frames accepted Untagged Incoming untagged frames are classified into the VLAN whose VLAN ID is the currently configured PVID. Frames sent Untagged Ingress Filtering On PVID 1 Configuring VLANs 577 Table 21-7 shows the default values or maximum values for VLAN features. Table 21-7. Additional VLAN Default and Maximum Values Feature Value Default VLAN VLAN 1 VLAN Name No VLAN name is configured except for VLAN 1, whose name “default” cannot be changed. VLAN Range 2–4093 Switchport mode Access Double-VLAN tagging Disabled If double-VLAN tagging is enabled, the default EtherType value is 802.1Q Maximum number of configurable MAC-to-VLAN bindings 128 Maximum number of 64 configurable IP Subnet-to-VLAN bindings GVRP Disabled If GVRP is enabled, the default port parameters are: • GVRP State: Disabled • Dynamic VLAN Creation: Disabled • GVRP Registration: Disabled Number of dynamic VLANs 1024 that can be assigned through GVRP Voice VLAN Disabled Voice VLAN DSCP value 46 Voice VLAN authentication mode Enabled 578 Configuring VLANs Configuring VLANs (Web) This section provides information about the OpenManage Switch Administrator pages for configuring and monitoring VLANs on a PowerConnect 7000 Series switch. For details about the fields on a page, click at the top of the page. VLAN Membership Use the VLAN Membership page to create VLANs and define VLAN groups stored in the VLAN membership table. To display the VLAN Membership page, click Switching → VLAN → VLAN Membership in the navigation panel. The VLAN Membership tables display which Ports and LAGs are members of the VLAN, and whether they’re tagged (T), untagged (U), or forbidden (F). The tables have two rows: Static and Current. Only the Static row is configurable. The Current row is updated either dynamically through GVRP or when the Static row is changed and Apply is clicked. There are two tables on the page: • Ports — Displays and assigns VLAN membership to ports. To assign membership, click in Static for a specific port. Each click toggles between U, T, and blank. See Table 21-8 for definitions. • LAGs — Displays and assigns VLAN membership to LAGs. To assign membership, click in Static for a specific LAG. Each click toggles between U, T, and blank. See Table 21-8 for definitions. Table 21-8. VLAN Port Membership Definitions Port Control Definition T Tagged: the interface is a member of a VLAN. All packets forwarded by the interface in this VLAN are tagged. The packets contain VLAN information. U Untagged: the interface is a VLAN member. Packets forwarded by the interface in this VLAN are untagged. F Forbidden: indicates that the interface is forbidden from becoming a member of the VLAN. This setting is primarily for GVRP, which enables dynamic VLAN assignment. Configuring VLANs 579 Table 21-8. VLAN Port Membership Definitions Port Control Definition Blank Blank: the interface is not a VLAN member. Packets in this VLAN are not forwarded on this interface. To perform additional port configuration, such as making the port a trunk port, use the Port Settings page. Figure 21-4. VLAN Membership 580 Configuring VLANs Adding a VLAN To create a VLAN: 1 Open the VLAN Membership page. 2 Click Add to display the Add VLAN page. 3 Specify a VLAN ID and a VLAN name. Figure 21-5. Add VLAN 4 Click Apply. Configuring Ports as VLAN Members To add member ports to a VLAN: 1 Open the VLAN Membership page. 2 From the Show VLAN menu, select the VLAN to which you want to assign ports. 3 In the Static row of the VLAN Membership table, click the blank field to assign the port as an untagged member. Figure 21-6 shows Gigabit Ethernet ports 5–8 being added to VLAN 300. Configuring VLANs 581 Figure 21-6. Add Ports to VLAN 4 Click Apply. 5 Verify that the ports have been added to the VLAN. 582 Configuring VLANs In Figure 21-7, the presence of the letter U in the Current row indicates that the port is an untagged member of the VLAN. Figure 21-7. Add Ports to VLAN Configuring VLANs 583 VLAN Port Settings Use the VLAN Port Settings page to add ports to an existing VLAN and to configure settings for the port. If you select Trunk or Access as the Port VLAN Mode, some of the fields are not configurable because of the requirements for that mode. NOTE: You can add ports to a VLAN through the table on the VLAN Membership page or through the PVID field on the Port Settings page. The PVID is the VLAN that untagged received packets are assigned to. To include a general-mode port in multiple VLANs, use the VLAN Membership page. To display the Port Settings page, click Switching → VLAN → Port Settings in the navigation panel. Figure 21-8. VLAN Port Settings From the Port Settings page, click Show All to see the current VLAN settings for all ports. You can change the settings for one or more ports by clicking the Edit option for a port and selecting or entering new values. 584 Configuring VLANs Figure 21-9. VLAN Settings for All Ports VLAN LAG Settings Use the VLAN LAG Settings page to map a LAG to a VLAN and to configure specific VLAN settings for the LAG. To display the LAG Settings page, click Switching → VLAN → LAG Settings in the navigation panel. Figure 21-10. VLAN LAG Settings Configuring VLANs 585 From the LAG Settings page, click Show All to see the current VLAN settings for all LAGs. You can change the settings for one or more LAGs by clicking the Edit option for a port and selecting or entering new values. Figure 21-11. 586 VLAN LAG Table Configuring VLANs Bind MAC to VLAN Use the Bind MAC to VLAN page to map a MAC address to a VLAN. After the source MAC address and the VLAN ID are specified, the MAC to VLAN configurations are shared across all ports of the switch. The MAC to VLAN table supports up to 128 entries. To display the Bind MAC to VLAN page, click Switching → VLAN → Bind MAC to VLAN in the navigation panel. Figure 21-12. Bind MAC to VLAN From the Bind MAC to VLAN page, click Show All to see the MAC addresses that are mapped to VLANs. From this page, you can change the settings for one or more entries or remove an entry. Configuring VLANs 587 Figure 21-13. MAC-VLAN Bind Table Bind IP Subnet to VLAN Use the Bind IP Subnet to VLAN page to assign an IP Subnet to a VLAN. The IP Subnet to VLAN configurations are shared across all ports of the switch. There can be up to 64 entries configured in this table. To display the Bind IP Subnet to VLAN page, click Switching → VLAN → Bind IP Subnet to VLAN in the navigation panel. Figure 21-14. 588 Bind IP Subnet to VLAN Configuring VLANs From the Bind IP Subnet to VLAN page, click Show All to see the IP subnets that are mapped to VLANs. From this page, you can change the settings for one or more entries or remove an entry. Figure 21-15. Subnet-VLAN Bind Table Configuring VLANs 589 GVRP Parameters Use the GVRP Parameters page to enable GVRP globally and configure the port settings. To display the GVRP Parameters page, click Switching → VLAN → GVRP Parameters in the navigation panel. Figure 21-16. GVRP Parameters From the GVRP Parameters page, click Show All to see the GVRP configuration for all ports. From this page, you can change the settings for one or more entries. NOTE: Per-port and per-LAG GVRP Statistics are available from the Statistics/RMON page. For more information, see "Monitoring Switch Traffic" on page 363. 590 Configuring VLANs Figure 21-17. GVRP Port Parameters Table Configuring VLANs 591 Protocol Group Use the Protocol Group page to configure which EtherTypes go to which VLANs, and then enable certain ports to use these settings. Protocol-based VLANs are most often used in situations where network segments contain hosts running multiple protocols. To display the Protocol Group page, click Switching → VLAN → Protocol Group in the navigation panel. Figure 21-18. 592 Protocol Group Configuring VLANs Adding a Protocol Group To add a protocol group: 1 Open the Protocol Group page. 2 Click Add to display the Add Protocol Group page. 3 Create a name for the group and associate a VLAN with the group. Figure 21-19. Add Protocol Group 4 Click Apply. 5 Click Protocol Group to return to the main Protocol Group page. 6 From the Group ID field, select the group to configure. 7 In the Protocol Settings table, select the protocol and interfaces to associate with the protocol-based VLAN. In Figure 21-20, the Protocol Group 1 (named IPX) is associated with the IPX protocol and ports 14–16. Ports 20-22 are selected in Available Ports list. After clicking the right arrow, they will be added to the Selected Ports list. Configuring VLANs 593 Figure 21-20. Configure Protocol Group 8 Click Apply. 9 Click Show All to see the protocol-based VLANs and their members. Figure 21-21. 594 Protocol Group Table Configuring VLANs Double VLAN Global Configuration Use the Double VLAN Global Configuration page to specify the value of the EtherType field in the first EtherType/tag pair of the double-tagged frame. To display the Double VLAN Global Configuration page, click Switching → VLAN → Double VLAN → Global Configuration in the navigation panel. Figure 21-22. Double VLAN Global Configuration Configuring VLANs 595 Double VLAN Interface Configuration Use the Double VLAN Interface Configuration page to specify the value of the EtherType field in the first EtherType/tag pair of the double-tagged frame. To display the Double VLAN Interface Configuration page, click Switching → VLAN → Double VLAN → Interface Configuration in the navigation panel. Figure 21-23. Double VLAN Interface Configuration To view a summary of the double VLAN configuration for all interfaces and to edit settings for one or more interfaces, click Show All. 596 Configuring VLANs Figure 21-24. Double VLAN Port Parameter Table Configuring VLANs 597 Voice VLAN Use the Voice VLAN Configuration page to configure and view voice VLAN settings that apply to the entire system and to specific interfaces. To display the page, click Switching → VLAN → Voice VLAN → Configuration in the navigation panel. Figure 21-25. Voice VLAN Configuration NOTE: IEEE 802.1X must be enabled on the switch before you disable voice VLAN authentication. Voice VLAN authentication can be disabled in order to allow VoIP phones that do not support authentication to send and receive unauthenticated traffic on the Voice VLAN. 598 Configuring VLANs Configuring VLANs (CLI) This section provides information about the commands you use to create and configure VLANs. For more information about the commands, see the PowerConnect 7000 Series CLI Reference Guide at support.dell.com/manuals. Creating a VLAN Beginning in Privileged EXEC mode, use the following commands to configure a VLAN and associate a name with the VLAN. Command Purpose configure Enter global configuration mode. vlan {vlan-id |vlanrange} Create a new VLAN or a range of VLANs and enter the interface configuration mode for the specified VLAN or VLAN range. • vlan-id—A valid VLAN IDs (Range: 2–4093). • vlan-range — A list of valid VLAN IDs to be added. List separate, non-consecutive VLAN IDs separated by commas (without spaces); use a hyphen to designate a range of IDs. (Range: 2–4093) name string Add a name to the specified VLAN. string — Comment or description to help identify a specific VLAN (Range: 1–32 characters). CTRL + Z Exit to Privileged EXEC mode. show vlan [id vlan-id | name vlan-name] Display VLAN information. • vlan-id — A valid VLAN ID. (Range: 1–4093) • vlan-name — A valid VLAN name string. (Range: 1–32 characters) Configuring a Port in Access Mode Beginning in Privileged EXEC mode, use the following commands to configure an untagged layer 2 VLAN interface and assign the interface to a VLAN. When a port is in access mode, it can only be a member of one untagged VLAN. When you configure the interface as a VLAN member, the Configuring VLANs 599 interface is automatically removed from its previous VLAN membership. You can configure each interface separately, or you can configure a range of interfaces with the same settings. Command Purpose configure Enter global configuration mode. interface interface Enter interface configuration mode for the specified interface. The interface variable includes the interface type and number, for example gigabitethernet 1/0/3. You can also specify a range of interfaces with the interface range command, for example, interface range gigabitethernet 1/0/8-12 configures interfaces 8, 9, 10, 11, and 12. switchport mode access Configure the interface as an untagged layer 2 VLAN interface. switchport access vlan Configure the interface as a member of the specified VLAN. vlan-id vlan-id — A valid VLAN ID of the VLAN to which the port is configured. (Range: 1–4093) CTRL + Z Exit to Privileged EXEC mode. show interfaces switchport interface Display information about the VLAN settings configured for the specified interface. Configuring a Port in Trunk Mode Beginning in Privileged EXEC mode, use the following commands to configure an interface as a layer 2 trunking interface, which connects two switches. Trunk mode ports support traffic tagged with different VLAN IDs. Untagged received traffic is switched in the native VLAN. Command Purpose configure Enter global configuration mode. 600 Configuring VLANs Command Purpose interface interface Enter interface configuration mode for the specified interface. The interface variable includes the interface type and number, for example gigabitethernet 1/0/3. You can also specify a range of interfaces with the interface range command, for example, interface range gigabitethernet 1/0/8-12 configures interfaces 8, 9, 10, 11, and 12. switchport mode trunk Configure the interface as a tagged layer 2 VLAN interface. Set the list of allowed VLANs that can receive and send switchport trunk traffic on this interface in tagged format when in trunking {allowed vlan vlanlist|native vlan vlan-id} mode. • allowed vlan-list — Set the list of allowed VLANs that can receive and send traffic on this interface in tagged format when in trunking mode. Separate non-consecutive VLAN IDs with a comma and no spaces. Use a hyphen to designate a range of IDs. The vlan-list format is all | [add | remove | except] vlanatom [vlan-atom...] where: • all—Specifies all VLANs from 1 to 4093. This keyword is not allowed on commands that do not permit all VLANs in the list to be set at the same time. • add—Adds the list of VLANs to the allowed set. • remove—Removes the list of VLANs from the allowed set. Removing the native VLAN from a trunk port forces the port to allow tagged packets only. • except—Allows all VLANs other than those in the list. • vlan-atom —Either a single VLAN number from 1 to 4093 or a continuous range of VLANs described by two VLAN numbers, the lesser one first, separated by a hyphen. • native vlan-id— The untagged VLAN. Untagged packets received on this interface are switched in the native VLAN. Transmitted packets in this VLAN are sent untagged. CTRL + Z Exit to Privileged EXEC mode. Configuring VLANs 601 Command Purpose show interfaces switchport interface Display information about the VLAN settings configured for the specified interface. The interface variable includes the interface type and number. 602 Configuring VLANs Configuring a Port in General Mode Beginning in Privileged EXEC mode, use the following commands to configure an interface with full 802.1q support and configure the VLAN membership information for the interface. Except when noted as required (for example, when configuring MAB, Voice VLAN, or 802.1x), it is recommended that operators use either trunk or access mode. Command Purpose configure Enter global configuration mode. interface interface Enter interface configuration mode for the specified interface. The interface variable includes the interface type and number, for example gigabitethernet 1/0/3. You can also specify a range of interfaces with the interface range command, for example, interface range gigabitethernet 1/0/8-12 configures interfaces 8, 9, 10, 11, and 12. switchport mode general Configure the interface as a tagged and an untagged layer 2 VLAN interface. switchport general allowed vlan [add|remove] vlan-list {tagged|untagged} Configure the VLAN membership for the port. You can also use this command to change the egress tagging for packets without changing the VLAN assignment. • add vlan-list — List of VLAN IDs to add. Separate nonconsecutive VLAN IDs with a comma and no spaces. Use a hyphen to designate a range of IDs. (Range: 1–4093) • remove vlan-list — List of VLAN IDs to remove. Separate nonconsecutive VLAN IDs with a comma and no spaces. Use a hyphen to designate a range of IDs. • tagged — Sets the port to transmit tagged packets for the VLANs. If the port is added to a VLAN without specifying tagged or untagged, the default is untagged. • untagged — Sets the port to transmit untagged packets for the VLANs. Configuring VLANs 603 Command Purpose switchport general pvid (Optional) Set the port VLAN ID. Untagged traffic that enters the switch through this port is tagged with the PVID. vlan-id vlan-id — PVID. The selected PVID assignment must be to an existing VLAN. (Range: 1–4093). Entering a PVID value does not remove the previous PVID value from the list of allowed VLANs. switchport general acceptable-frame-type tagged-only (Optional) Specifies that the port will only accept tagged frames. Untagged frames are dropped at ingress. switchport general ingress-filtering disable (Optional) Turn off ingress filtering so that all received tagged frames are forwarded whether or not the port is a member of the VLAN in the tag. CTRL + Z Exit to Privileged EXEC mode. show interfaces switchport interface Display information about the VLAN settings configured for the specified interface. The interface variable includes the interface type and number. Configuring VLAN Settings for a LAG The VLAN mode and memberships settings you configure for a port are also valid for a LAG (port channel). Beginning in Privileged EXEC mode, use the following commands to configure the VLAN mode for a LAG. Once you specify the switchport mode settings for a LAG, you can configure other VLAN memberships settings that are valid that the switchport mode. Command Purpose configure Enter global configuration mode. interface port-channel Enter interface configuration mode for the specified interface. channel-id channel-id — Specific port channel. (Range 1–48). You can also specify a range of LAGs with the interface range port-channel command, for example, interface range portchannel 4-8. switchport mode [access|general|trunk] 604 Configure the interface as an untagged layer 2 VLAN interface. Configuring VLANs Command Purpose CTRL + Z Exit to Privileged EXEC mode. show interfaces Display information about the VLAN settings configured switchport port-channel for the specified LAG. channel-id Configuring VLANs 605 Configuring Double VLAN Tagging Beginning in Privileged EXEC mode, use the following commands to configure an interface to send and accept frames with double VLAN tagging. Command Purpose configure Enter global configuration mode. interface interface Enter interface configuration mode for the specified interface. The interface variable includes the interface type and number, for example gigabitethernet 1/0/3. You can also specify a range of interfaces with the interface range command, for example, interface range gigabitethernet 1/0/8-12 configures interfaces 8, 9, 10, 11, and 12. mode dvlan-tunnel Enable Double VLAN Tunneling on the specified interface. exit Exit to global configuration mode dvlan-tunnel ethertype {802.1Q | vman | custom <0-65535>} [primary-tpid] Configure the EtherType to use for interfaces with double VLAN tunneling enabled. • 802.1Q — Configures the EtherType as 0x8100. • vman — Configures the EtherType as 0x88A8. • custom — Custom configures the EtherType for the DVLAN tunnel. The value must be 0-65535. • primary-tpid — Configure the primary (outer) TPID. If this parameter is not present, the inner TPID is configured. CTRL + Z Exit to Privileged EXEC mode. show dvlan-tunnel Display all interfaces enabled for Double VLAN Tunneling show dvlan-tunnel interface {interface | all} Display detailed information about Double VLAN Tunneling for the specified interface or all interfaces. 606 Configuring VLANs Configuring MAC-Based VLANs Beginning in Privileged EXEC mode, use the following commands to associate a MAC address with a configured VLAN. The VLAN does not need to be configured on the system to associate a MAC address with it. You can create up to 256 VLAN to MAC address associations. Command Purpose configure Enter global configuration mode. vlan database Enter VLAN database mode. vlan association mac Associate a MAC address with a VLAN. mac-address vlan-id • mac-address — MAC address to associate. (Range: Any MAC address in the format xxxx.xxxx.xxxx or xx:xx:xx:xx:xx:xx) • vlanid — VLAN to associate with subnet. (Range: 14093) CTRL + Z Exit to Privileged EXEC mode. show vlan association mac [mac-address] Display the VLAN associated with a specific configured MAC address. If no MAC address is specified, the VLAN associations of all the configured MAC addresses are displayed. Configuring VLANs 607 Configuring IP-Based VLANs Beginning in Privileged EXEC mode, use the following commands to associate an IP subnet with a configured VLAN. The VLAN does not need to be configured on the system to associate an IP subnet with it. You can create up to 256 VLAN to MAC address associations. Command Purpose configure Enter global configuration mode. vlan database Enter VLAN database mode. vlan association subnet Associate an IP subnet with a VLAN. ip-address subnet-mask vlanid • ip-address — Source IP address. (Range: Any valid IP address) • subnet-mask — Subnet mask. (Range: Any valid subnet mask) • vlanid — VLAN to associated with subnet. (Range: 14093) CTRL + Z Exit to Privileged EXEC mode. show vlan association subnet [ip-address ip- Display the VLAN associated with a specific configured IPAddress and netmask. If no IP Address and net mask are specified, the VLAN associations of all the configured IPsubnets are displayed. mask ] Configuring a Protocol-Based VLAN Beginning in Privileged EXEC mode, use the following commands to create and name a protocol group, and associate VLANs with the protocol group. When you create a protocol group, the switch automatically assigns it a unique group ID number. The group ID is used for both configuration and script generation to identify the group in subsequent commands. A protocol group may have more than one interface associated with it, but each interface and protocol combination can be associated with one group only. If adding an interface to a group causes any conflicts with protocols currently associated with the group, adding the interface(s) to the group fails and no interfaces are added to the group. Ensure that the referenced VLAN is created prior to the creation of the protocol-based group except when GVRP is expected to create the VLAN. 608 Configuring VLANs Command Purpose configure Enter global configuration mode. vlan protocol group Create a new protocol group. exit Exit to Privileged EXEC mode. show port protocol all Obtain the group ID for the newly configured group. configure Enter global configuration mode. name vlan protocol group add Add any EtherType protocol to the protocol-based VLAN protocol groupid groups identified by groupid. A group may have more than one protocol associated with it. Each interface and ethertype value protocol combination can be associated with one group only. If adding a protocol to a group causes any conflicts with interfaces currently associated with the group, this command fails and the protocol is not added to the group. • groupid — The protocol-based VLAN group ID. • protocol — The protocol you want to add. The ethertype can be any valid number in the range 0x0600-0xffff. protocol vlan group all groupid (Optional) Add all physical interfaces to the protocolbased group identified by groupid. You can add individual interfaces to the protocol-based group as shown in the next two commands. groupid — The protocol-based VLAN group ID. interface interface Enter interface configuration mode for the specified interface. interface — Specific interface type and number, such as gi1/0/8. protocol vlan group groupid Add the physical unit/port interface to the protocol-based group identified by groupid. groupid — The protocol-based VLAN group ID. exit Exit to global configuration mode. vlan database Enter VLAN database mode. Configuring VLANs 609 Command Purpose protocol group groupid Attach a VLAN ID to the protocol-based group identified by groupid. A group may only be associated with one VLAN at a time. However, the VLAN association can be changed. vlanid • groupid — The protocol-based VLAN group ID, which is automatically generated when you create a protocolbased VLAN group with the vlan protocol group command. To see the group ID associated with the name of a protocol group, use the show port protocol all command. • vlanid — A valid VLAN ID. CTRL + Z Exit to Privileged EXEC mode. show port protocol [all| Display the Protocol-Based VLAN information for either groupid] the entire system or for the indicated group. Configuring GVRP Beginning in Privileged EXEC mode, use the following commands to enable GVRP on the switch and on an interface, and to configure various GVRP settings. Command Purpose configure Enter global configuration mode. gvrp enable Enable GVRP on the switch. interface interface Enter interface configuration mode for the specified port or LAG. The interface variable includes the interface type and number, for example gigabitethernet 1/0/3 or portchannel 3. You can also specify a range of interfaces with the interface range command, for example, interface range gigabitethernet 1/0/8-12 configures interfaces 8, 9, 10, 11, and 12. gvrp enable 610 Enable GVRP on the interface. Configuring VLANs Command Purpose switchport forbidden vlan {add vlanlist|remove vlan-list} (Optional) Forbids adding the specified VLANs to a port. To revert to allowing the addition of specific VLANs to the port, use the remove parameter of this command. add vlan-list — List of valid VLAN IDs to add to the forbidden list. Separate nonconsecutive VLAN IDs with a comma and no spaces. Use a hyphen to designate a range of IDs. remove vlan-list — List of valid VLAN IDs to remove from the forbidden list. Separate nonconsecutive VLAN IDs with a comma and no spaces. Use a hyphen to designate a range of IDs. gvrp registration-forbid (Optional) Deregister all VLANs on a port and prevent any dynamic registration on the port. gvrp vlan-creationforbid (Optional) Disable dynamic VLAN creation. exit Exit to global configuration mode. vlan database Enter VLAN database mode. vlan makestatic vlan-id (Optional) Change a dynamically created VLAN (one that is created by GVRP registration) to a static VLAN (one that is permanently configured and defined). vlan-id — Valid vlan ID. Range is 2-4093. CTRL + Z Exit to Privileged EXEC mode. show gvrp configuration Display GVRP configuration information. Timer values are displayed. Other data shows whether GVRP is enabled and which ports are running GVRP. Configuring VLANs 611 Configuring Voice VLANs Beginning in Privileged EXEC mode, use the following commands to enable the Voice VLAN feature on the switch and on an interface. Command Purpose configure Enter global configuration mode. voice vlan Enable the voice vlan capability on the switch. interface interface Enter interface configuration mode for the specified interface. interface — Specific interface, such as gi1/0/8. You can also specify a range of interfaces with the interface range command, for example, interface range gi1/0/8-12 enters Interface Configuration mode for ports 8–12. voice vlan {vlanid | Enable the voice vlan capability on the interface. dot1p priority | none | • vlanid —The voice VLAN ID. untagged | data priority {trust | untrust} | auth • priority —The Dot1p priority for the voice VLAN on the port. {enable | disable} | dscp value} • trust—Trust the dot1p priority or DSCP values contained in packets arriving on the voice vlan port. • untrust—Do not trust the dot1p priority or DSCP values contained in packets arriving on the voice vlan port. • auth {enable | disable} — Use enable to allow voice traffic on unauthorized voice vlan port. Use disable to prevent voice traffic on an Unauthorized voice vlan port • dscp value —The DSCP value (Range: 0–64). CTRL + Z Exit to Privileged EXEC mode. show voice vlan [interface {interface |all}] Display voice VLAN configuration information for the switch, for the specified interface, or for all interfaces. 612 Configuring VLANs VLAN Configuration Examples This section contains the following examples: • Configuring VLANs Using Dell OpenManage Administrator • Configuring VLANs Using the CLI • Configuring a Voice VLAN NOTE: For an example that shows how to use a RADIUS server to provide VLAN information, see "Controlling Authentication-Based VLAN Assignment" on page 508. For an example that shows how to allow the switch to dynamically create RADIUS-assigned VLANS, see "Allowing Dynamic VLAN Creation of RADIUS-Assigned VLANs" on page 512. This example assumes that network administrator wants to create the VLANs in Table 21-9: Table 21-9. Example VLANs VLAN ID VLAN Name VLAN Type Purpose 100 Engineering Port-based All employees in the Engineering department use this VLAN. Confining this department’s traffic to a single VLAN helps reduce the amount of traffic in the broadcast domain, which increases bandwidth. 200 Marketing Port-based All employees in the Marketing department use this VLAN. 300 Sales MAC-based The sales staff works remotely but occasionally comes to the office. Since these employees do not have assigned work areas, they typically plug their laptops into a network port in an available cubicle, office, or conference room. 400 Payroll Port-based The payroll department has sensitive traffic and needs its own VLAN to help keep that traffic private. Configuring VLANs 613 Figure 21-26 shows the network topology for this example. As the figure shows, there are two switches, two file servers, and many hosts. One switch has an uplink port that connects it to a layer 3 device and the rest of the corporate network. Figure 21-26. Network Topology for Port-Based VLAN Configuration LAN/WAN Switch 1 VLAN 400 Payroll Payroll Server Switch 2 VLAN 100 Engineering VLAN 200 Marketing Payroll Hosts Marketing Hosts Shared File Engineering Server Hosts The network in Figure 21-26 has the following characteristics: 614 • Each connection to a host represents multiple ports and hosts. • The Payroll and File servers are connected to the switches through a LAG. • Some of the Marketing hosts connect to Switch 1, and some connect to Switch 2. • The Engineering and Marketing departments share the same file server. • Because security is a concern for the Payroll VLAN, the ports and LAG that are members of this VLAN will accept and transmit only traffic tagged with VLAN 400. • The Sales staff might connect to a port on Switch 1 or Switch 2. Configuring VLANs Table 21-10 shows the port assignments on the switches. Table 21-10. Switch Port Connections Port/LAG Function Switch 1 1 Connects to Switch 2 2–15 Host ports for Payroll 16–20 Host ports for Marketing LAG1 (ports 21–24) Connects to Payroll server Switch 2 1 Connects to Switch 1 2–10 Host ports for Marketing 11–30 Host ports for Engineering LAG1 (ports 35–39) Connects to file server LAG2 (ports 40–44) Uplink to router. Configuring VLANs 615 Configuring VLANs Using Dell OpenManage Administrator This example shows how to perform the configuration by using the webbased interface. Configure the VLANs and Ports on Switch 1 Use the following steps to configure the VLANs and ports on Switch 1. None of the hosts that connect to Switch 1 use the Engineering VLAN (VLAN 100), so it is not necessary to create it on that switch. To configure Switch 1: 1 Create the Marketing, Sales, and Payroll VLANs. a From the Switching → VLAN → VLAN Membership page, click Add. b In the VLAN ID field, enter 200. c In the VLAN Name field, enter Marketing. d Click Apply. Figure 21-27. e 616 Add VLANs Repeat steps b–d to create VLANs 300 (Sales) and 400 (Payroll). Configuring VLANs 2 Assign ports 16–20 to the Marketing VLAN. a From the Switching → VLAN → VLAN Membership page, select 200-Marketing from the Show VLAN field. b In the Static row, click the space for ports 16–20 so the U (untagged) displays for each port. Figure 21-28. VLAN Membership - VLAN 200 3 Click Apply. 4 Assign ports 2–15 and LAG1 to the Payroll VLAN. a From the Switching → VLAN → VLAN Membership page, select 400-Payroll from the Show VLAN field. b In the Static row, click the space for ports 2–15 and LAG 1 so the U (untagged) displays for each port, and then click Apply. Configuring VLANs 617 5. Configure LAG 1 to be in general mode and specify that the LAG will accept tagged or untagged frames, but that untagged frames will be transmitted tagged with PVID 400. a. From the Switching → VLAN → LAG Settings page, make sure Po1 is selected. b. Configure the following settings: c. • Port VLAN Mode — General • PVID — 400 • Frame Type — AdmitAll Click Apply. Figure 21-29. LAG Settings 6 Configure port 1 as a trunk port. 618 a From the Switching → VLAN → Port Settings page, make sure port Gi1/0/1 is selected. b From the Port VLAN Mode field, select Trunk. c Click Apply. Configuring VLANs Figure 21-30. Trunk Port Configuration 7 From the Switching → VLAN → VLAN Membership page, verify that port 1 is marked as a tagged member (T) for each VLAN. Figure 21-31 shows VLAN 200, in which port 1 is a tagged member, and ports 16–20 are untagged members. Figure 21-31. Trunk Port Configuration 8 Configure the MAC-based VLAN information. a Go to the Switching → VLAN → Bind MAC to VLAN page. b In the MAC Address field, enter a valid MAC address, for example 00:1C:23:55:E9:8B. c In the Bind to VLAN field, enter 300, which is the Sales VLAN ID. d Click Apply. Configuring VLANs 619 Figure 21-32. e Trunk Port Configuration Repeat steps b–d to add additional MAC address-to-VLAN information for the Sales department. 9 To save the configuration so that it persists across a system reset, use the following steps: a Go to the System → File Management→ Copy Files page b Select Copy Configuration and ensure that Running Config is the source and Startup Config is the destination. c Click Apply. Configure the VLANs and Ports on Switch 2 Use the following steps to configure the VLANs and ports on Switch 2. Many of the procedures in this section are the same as procedures used to configure Switch 1. For more information about specific procedures, see the details and figures in the previous section. To configure Switch 2: 1. Create the Engineering, Marketing, Sales, and Payroll VLANs. Although the Payroll hosts do not connect to this switch, traffic from the Payroll department must use Switch 2 to reach the rest of the network and Internet through the uplink port. For that reason, Switch 2 must be aware of VLAN 400 so that traffic is not rejected by the trunk port. 620 Configuring VLANs 2. Configure LAG 1 as a general port so that it can be a member of multiple VLANs. a. From the Switching → VLAN → LAG Settings page, make sure Po1 is selected. b. From the Port VLAN Mode field, select General. c. Click Apply. 3. Configure port 1 as a trunk port. 4. Configure LAG2 as a trunk port. 5. Assign ports 1–10 to VLAN 200 as untagged (U) members. 6. Assign ports 11–30 to VLAN 100 as untagged (U) members. 7. Assign LAG1 to VLAN 100 and 200 as a tagged (T) member. 8. Assign port 1 and LAG2 to VLAN 100, VLAN 200, VLAN 300, and VLAN 400 as a tagged (T) member. 9. Configure the MAC-based VLAN information. 10. If desired, copy the running configuration to the startup configuration. Configuring VLANs Using the CLI This example shows how to perform the same configuration by using CLI commands. Configure the VLANs and Ports on Switch 1 Use the following steps to configure the VLANs and ports on Switch 1. None of the hosts that connect to Switch 1 use the Engineering VLAN (VLAN 100), so it is not necessary to create it on that switch. To configure Switch 1: 1. Create VLANs 200 (Marketing), 300 (Sales), and 400 (Payroll), and associate the VLAN ID with the appropriate name. console#configure console(config)#vlan 200,300,400 console(config)#vlan 200 console(config-vlan200)#name Marketing console(config-vlan200)#exit console(config)#vlan 300 Configuring VLANs 621 console(config-vlan300)#name Sales console(config-vlan300)#exit console(config)#vlan 400 console(config-vlan400)#name Payroll console(config-vlan400)#exit 2. Assign ports 16–20 to the Marketing VLAN. console(config)#interface range gigabitEthernet 1/0/16-20 console(config-if)#switchport mode access console(config-if)#switchport access vlan 200 console(config-if)#exit 3. Assign ports 2–15 to the Payroll VLAN console(config)#interface range gigabitEthernet 1/0/2-15 console(config-if)#switchport mode access console(config-if)#switchport access vlan 400 console(config-if)#exit 4. Assign LAG1 to the Payroll VLAN and specify that frames will always be transmitted tagged with a VLAN ID of 400. By default, all VLANs are members of a trunk port. console(config)#interface port-channel 1 console(config-if-Po1)#switchport mode trunk console(config-if-Po1)#switchport trunk native vlan 400 console(config-if-Po1)#exit 5. Configure port 1 as a trunk port and add VLAN 200, VLAN 300, and VLAN 400 as members. All VLANs are added to trunk ports by default, including those created after the trunk port has been created. console(config)#interface gigabitEthernet 1/0/1 console(config-if-Gi1/0/1)#switchport mode trunk console(config-if-Gi1/0/1)#exit 622 Configuring VLANs 6. Configure the MAC-based VLAN information. The following commands show how to associate a system with a MAC address of 00:1C:23:55:E9:8B with VLAN 300. Repeat the vlan association mac command to associate additional MAC addresses with VLAN 300. console(config)#vlan database console(config-vlan)#vlan association mac 00:1C:23:55:E9:8B 300 console(config-vlan)#exit console(config)#exit 7. To save the configuration so that it persists across a system reset, use the following command: console#copy running-config startup-config 8. View the VLAN settings. console#show vlan VLAN ----1 Name --------Default 200 Marketing 300 400 Sales Payroll Ports -----------Po1-48, gi1/0/2-15, gi1/0/21-24 te1/1/1-2 gi1/0/1, gi1/0/16-20 gi1/0/1 gi1/0/1-15 Type --------Default Authorization ------------Required Static Required Static Static Required Required 9. View the VLAN membership information for a port. console#show interfaces switchport gi1/0/1 Port: Gi1/0/1 VLAN Membership mode:Trunk Mode Operating parameters: PVID: 1 Ingress Filtering: Enabled Acceptable Frame Type: VLAN Only Default Priority: 0 GVRP status:Disabled Configuring VLANs 623 Protected:Disabled Port Gi1/0/1 is member in: VLAN ---200 300 400 Name Egress rule ----------------- ----------Marketing Tagged Sales Tagged Payroll Tagged Type -------Static Static Static Configure the VLANs and Ports on Switch 2 Use the following steps to configure the VLANs and ports on Switch 2. Many of the procedures in this section are the same as procedures used to configure Switch 1. For more information about specific procedures, see the details and figures in the previous section. To configure Switch 2: 1. Create the Engineering, Marketing, Sales, and Payroll VLANs. Although the Payroll hosts do not connect to this switch, traffic from the Payroll department must use Switch 2 to reach the rest of the network and Internet through the uplink port. For that reason, Switch 2 must be aware of VLAN 400 so that traffic is not rejected by the trunk port. 2. Configure ports 2-10 as access ports and add VLAN 200 to the ports. 3. Configure ports 11–30 as access ports and add VLAN 100 to the ports. 4. Configure LAG 1 as a general port so that it can be a member of multiple untagged VLANs and add VLAN 100 and VLAN 200 to the LAG. 5. Configure port 1 and LAG 2 trunk ports and add VLAN 100, VLAN 200, VLAN 300, and VLAN 400 to the port and LAG. 6. Configure the MAC-based VLAN information. 7. If desired, copy the running configuration to the startup configuration. 8 View VLAN information for the switch and ports. 624 Configuring VLANs Configuring a Voice VLAN The commands in this example create a VLAN for voice traffic with a VLAN ID of 25. Port 10 is set to an 802.1Q VLAN. In in this example, there are multiple devices connected to port 10, so the port must be in general mode in order to enable MAC-based 802.1X authentication. Next, Voice VLAN is enabled on the port with the Voice VLAN ID set to 25. Finally, Voice VLAN authentication is disabled on port 10 because the phone connected to that port does not support 802.1X authentication. All other devices are required to use 802.1X authentication for network access. For more information about 802.1X authentication, see "Configuring Port and System Security" on page 481. NOTE: In an environment where the IP phone uses LLDP-MED to obtain configuration information, an additional step to enable LLDP-MED on the interface would be required by issuing the lldp med command in Interface Configuration mode. To configure the switch: 1 Create the voice VLAN. console#configure console(config)#vlan 25 console(config-vlan25)#exit 2 Enable the Voice VLAN feature on the switch. console(config)#voice vlan 3 Configure port 10 to be in general mode. console(config)#interface gi1/0/10 console(config-if-Gi1/0/10)#switchport mode general 4 Enable port-based 802.1X authentication on the port. This step is required only if there are multiple devices that use port-based authentication connected to the port. console(config-if-Gi1/0/10)#dot1x port-control mac-based 5 Enable the voice VLAN feature on the interface console(config-if-Gi1/0/10)#voice vlan 25 Configuring VLANs 625 6 Disable authentication for the voice VLAN on the port. This step is required only if the voice phone does not support port-based authentication. console(config-if-Gi1/0/10)#voice vlan auth disable 7 Exit to Privileged Exec mode. console(config-if-Gi1/0/10)# 8 View the voice VLAN settings for port 10. console#show voice vlan interface gi1/0/10 Interface............................. Voice VLAN Interface Mode............. Voice VLAN ID......................... Voice VLAN COS Override............... Voice VLAN DSCP Value................. Voice VLAN Port Status................ Voice VLAN Authentication............. Gi1/0/10 Enabled 25 False 46 Disabled Disabled Configuring a Private VLAN 1 Configure the VLANs and their roles: This example configures VLAN 100 as the primary VLAN, secondary VLAN 101 as the community VLAN and secondary VLANs 102 and 103 as the isolated VLANs: switch# configure switch(config)# vlan 100 switch(config-vlan-100)# switch(config-vlan-100)# switch(config)# vlan 101 switch(config-vlan-101)# switch(config-vlan-101)# switch(config)# vlan 102 switch(config-vlan-102)# switch(config-vlan-102)# switch(config)# vlan 103 switch(config-vlan-103)# switch(config-vlan-103)# private-vlan primary exit private-vlan community exit private-vlan isolated exit private-vlan isolated exit 2 Associate the community and isolated VLANs with the primary VLAN. switch(config)# vlan 100 626 Configuring VLANs switch(config-vlan-100)# private-vlan association 101-102 switch(config-vlan-100)# exit This completes the configuration of the private VLAN. The only remaining step is to assign the ports to the private VLAN. 3 Assign the router connected port to the primary VLAN: console(config)#interface te1/1/1 console(config-if-Te1/1/1)#switchport mode private-vlan promiscuous console(config-if-Te1/1/1)#switchport private-vlan mapping 100 101-102 console(config-if-Te1/1/1)#exit 4 Assign the community VLAN ports: console(config)#interface gi1/0/11 console(config-if-Gi1/0/11)#switchport mode private-vlan host console(config-if-Gi1/0/11)#switchport private-vlan hostassociation 100 101 console(config-if-Gi1/0/11)#interface gi1/0/12 console(config-if-Gi1/0/12)#switchport mode private-vlan host console(config-if-Gi1/0/12)#switchport private-vlan hostassociation 100 101 5 Assign the isolated VLAN ports: console(config)#interface gi1/0/10 console(config-if-Gi1/0/10)#switchport mode private-vlan host console(config-if-Gi1/0/10)#switchport private-vlan hostassociation 100 102 console(config-if-Gi1/0/10)#interface gi2/0/10 console(config-if-Gi2/0/10)#switchport mode private-vlan host console(config-if-Gi2/0/10)#switchport private-vlan hostassociation 100 102 console(config-if-Gi2/0/10)#interface gi2/0/11 console(config-if-Gi2/0/11)#switchport mode private-vlan host console(config-if-Gi2/0/11)#switchport private-vlan hostassociation 100 102 6 Show the configuration: console(config)#show vlan private-vlan type VLAN ---100 101 102 Type ----------------------primary community isolated Configuring VLANs 627 103 isolated console#show vlan private-vlan Primary VLAN Secondary VLAN Community ------------ -------------- ------------------100 102 101 console(config)#show vlan VLAN ----1 100 101 102 628 Name Ports ----------- ------------default Po1-128, Te1/1/1, Gi1/0/1-10, Gi1/0/13-24 VLAN0100 Te1/1/1, Gi1/0/11-12 VLAN0101 Gi1/0/11 VLAN0102 Gi1/0/12 Configuring VLANs Type ------------Default Static Static Static 22 Configuring the Spanning Tree Protocol This chapter describes how to configure the Spanning Tree Protocol (STP) settings on the switch. The topics covered in this chapter include: • STP Overview • Default STP Values • Configuring Spanning Tree (Web) • Configuring Spanning Tree (CLI) • STP Configuration Examples STP Overview STP is a layer 2 protocol that provides a tree topology for switches on a bridged LAN. STP allows a network to have redundant paths without the risk of network loops. STP uses the spanning-tree algorithm to provide a single path between end stations on a network. PowerConnect 7000 Series switches support Classic STP, Multiple STP, and Rapid STP. What Are Classic STP, Multiple STP, and Rapid STP? Classic STP provides a single path between end stations, avoiding and eliminating loops. Multiple Spanning Tree Protocol (MSTP) supports multiple instances of Spanning Tree to efficiently channel VLAN traffic over different interfaces. Each instance of the Spanning Tree behaves in the manner specified in IEEE 802.1w, Rapid Spanning Tree (RSTP), with slight modifications in the working but not the end effect (chief among the effects, is the rapid transitioning of the port to Forwarding). The difference between the RSTP and the traditional STP (IEEE 802.1d) is the ability to configure and Configuring the Spanning Tree Protocol 629 recognize full-duplex connectivity and ports which are connected to end stations, resulting in rapid transitioning of the port to the Forwarding state and the suppression of Topology Change Notifications. MSTP is compatible to both RSTP and STP. It behaves appropriately to STP and RSTP bridges. A MSTP bridge can be configured to behave entirely as a RSTP bridge or a STP bridge. How Does STP Work? The switches (bridges) that participate in the spanning tree elect a switch to be the root bridge for the spanning tree. The root bridge is the switch with the lowest bridge ID, which is computed from the unique identifier of the bridge and its configurable priority number. When two switches have an equal bridge ID value, the switch with the lowest MAC address is the root bridge. After the root bridge is elected, each switch finds the lowest-cost path to the root bridge. The port that connects the switch to the lowest-cost path is the root port on the switch. The switches in the spanning tree also determine which ports have the lowest-path cost for each segment. These ports are the designated ports. Only the root ports and designated ports are placed in a forwarding state to send and receive traffic. All other ports are put into a blocked state to prevent redundant paths that might cause loops. To determine the root path costs and maintain topology information, switches that participate in the spanning tree use Bridge Protocol Data Units (BPDUs) to exchange information. 630 Configuring the Spanning Tree Protocol How Does MSTP Operate in the Network? In the following diagram of a small 802.1d bridged network, STP is necessary to create an environment with full connectivity and without loops. Figure 22-1. Small Bridged Network Assume that Switch A is elected to be the Root Bridge, and Port 1 on Switch B and Switch C are calculated to be the root ports for those bridges, Port 2 on Switch B and Switch C would be placed into the Blocking state. This creates a loop-free topology. End stations in VLAN 10 can talk to other devices in VLAN 10, and end stations in VLAN 20 have a single path to communicate with other VLAN 20 devices. Configuring the Spanning Tree Protocol 631 Figure 22-2 shows the logical single STP network topology. Figure 22-2. Single STP Topology For VLAN 10 this single STP topology is fine and presents no limitations or inefficiencies. On the other hand, VLAN 20's traffic pattern is inefficient. All frames from Switch B will have to traverse a path through Switch A before arriving at Switch C. If the Port 2 on Switch B and Switch C could be used, these inefficiencies could be eliminated. MSTP does just that, by allowing the configuration of MSTIs based upon a VLAN or groups of VLANs. In this simple case, VLAN 10 could be associated with Multiple Spanning Tree Instance (MSTI)1 with an active topology similar to Figure 22-2 and VLAN 20 could be associated with MSTI 2 where Port 1 on both Switch A and Switch B begin discarding and all others forwarding. This simple modification creates an active topology with a better distribution of network traffic and an increase in available bandwidth. 632 Configuring the Spanning Tree Protocol The logical representation of the MSTP environment for these three switches is shown in Figure 22-3. Figure 22-3. Logical MSTP Environment Configuring the Spanning Tree Protocol 633 In order for MSTP to correctly establish the different MSTIs as above, some additional changes are required. For example, the configuration would have to be the same on each and every bridge. That means that Switch B would have to add VLAN 10 to its list of supported VLANs (shown in Figure 22-3 with a *). This is necessary with MSTP to allow the formation of Regions made up of all switches that exchange the same MST Configuration Identifier. It is within only these MST Regions that multiple instances can exist. It will also allow the election of Regional Root Bridges for each instance. One common and internal spanning tree (CIST) Regional Root for the CIST and an MSTI Regional Root Bridge per instance will enable the possibility of alternate paths through each Region. Above Switch A is elected as both the MSTI 1 Regional Root and the CIST Regional Root Bridge, and after adjusting the Bridge Priority on Switch C in MSTI 2, it would be elected as the MSTI 2 Regional Root. To further illustrate the full connectivity in an MSTP active topology, the following rules apply: 1 Each Bridge or LAN is in only one Region. 2 Every frame is associated with only one VID. 3 Frames are allocated either to the IST or MSTI within any given Region. 4 The internal spanning tree (IST) and each MSTI provides full and simple connectivity between all LANs and Bridges in a Region. 5 All Bridges within a Region reach a consistent agreement as to which ports interconnect that Region to a different Region and label those as Boundary Ports. 6 At the Boundary Ports, frames allocated to the CIST or MSTIs are forwarded or not forwarded alike. 7 The CIST provides full and simple connectivity between all LANs and Bridges in the network. 634 Configuring the Spanning Tree Protocol MSTP with Multiple Forwarding Paths Consider the physical topology shown in Figure 22-4. It might be assumed that MSTI 2 and MSTI 3 would follow the most direct path for VLANs 20 and 30. However, using the default path costs, this is not the case. MSTI operates without considering the VLAN membership of the ports. This results in unexpected behavior if the active topology of an MSTI depends on a port that is not a member of the VLAN assigned to the MSTI and the port is selected as root port. In this configuration, port TE 1/0/11 is selected as the root port and ports TE1/0/12 and TE1/0/13 are blocked. To resolve the issue, set the port path cost of the directly connected links to allow the MSTIs to connect directly. Figure 22-4. MSTP with Multiple Forwarding Paths Configuring the Spanning Tree Protocol 635 What are the Optional STP Features? The PowerConnect 7000 Series switches support the following optional STP features: • BPDU flooding • PortFast • BPDU filtering • Root guard • Loop guard • BPDU protection BPDU Flooding The BPDU flooding feature determines the behavior of the switch when it receives a BPDU on a port that is disabled for spanning tree. If BPDU flooding is configured, the switch will flood the received BPDU to all the ports on the switch which are similarly disabled for spanning tree. Port Fast The PortFast feature reduces the STP convergence time by allowing edge ports that are connected to end devices (such as a desktop computer, printer, or file server) to transition to the forwarding state without going through the listening and learning states. BPDU Filtering Ports that have the PortFast feature enabled continue to transmit BPDUs. The BPDU filtering feature prevents PortFast-enabled ports from sending BPDUs. If BPDU filtering is configured globally on the switch, the feature is automatically enabled on all operational PortFast-enabled ports. These ports are typically connected to hosts that drop BPDUs. However, if an operational edge port receives a BPDU, the BPDU filtering feature disables PortFast and allows the port to participate in the spanning-tree calculation. Enabling BPDU filtering on a specific port prevents the port from sending BPDUs and allows the port to drop any BPDUs it receives. 636 Configuring the Spanning Tree Protocol Root Guard Enabling root guard on a port ensures that the port does not become a root port or a blocked port. When a switch is elected as the root bridge, all ports are designated ports unless two or more ports of the root bridge are connected together. If the switch receives superior STP BPDUs on a root-guard enabled port, the root guard feature moves this port to a root-inconsistent STP state, which is effectively equal to a listening state. No traffic is forwarded across this port. In this way, the root guard feature enforces the position of the root bridge. When the STP mode is MSTP, the port may be a designated port in one MSTI and an alternate port in the CIST, etc. Root guard is a per port (not a per port per instance command) configuration, so all the MSTP instances this port participates in should not be in a root role. Loop Guard Loop guard protects a network from forwarding loops induced by BPDU packet loss. The reasons for failing to receive packets are numerous, including heavy traffic, software problems, incorrect configuration, and unidirectional link failure. When a non-designated port no longer receives BPDUs, the spanning-tree algorithm considers that this link is loop free and begins transitioning the link from blocking to forwarding. Once in forwarding state, the link may create a loop in the network. Enabling loop guard prevents such accidental loops. When a port is no longer receiving BPDUs and the max age timer expires, the port is moved to a loopinconsistent blocking state. In the loop-inconsistent blocking state, traffic is not forwarded so the port behaves as if it is in the blocking state. The port will remain in this state until it receives a BPDU. It will then transition through the normal spanning tree states based on the information in the received BPDU. NOTE: Loop Guard should be configured only on non-designated ports. These include ports in alternate or backup roles. Root ports and designated ports should not have loop guard enabled so that they can forward traffic. Configuring the Spanning Tree Protocol 637 BPDU Protection When the switch is used as an access layer device, most ports function as edge ports that connect to a device such as a desktop computer or file server. The port has a single, direct connection and is configured as an edge port to implement the fast transition to a forwarding state. When the port receives a BPDU packet, the system sets it to non-edge port and recalculates the spanning tree, which causes network topology flapping. In normal cases, these ports do not receive any BPDU packets. However, someone may forge BPDU to maliciously attack the switch and cause network flapping. BPDU protection can be enabled in RSTP to prevent such attacks. When BPDU protection is enabled, the switch disables an edge port that has received BPDU and notifies the network manager about it. 638 Configuring the Spanning Tree Protocol Default STP Values Spanning tree is globally enabled on the switch and on all ports and LAGs. Table 22-1 summarizes the default values for STP. Table 22-1. STP Defaults Parameter Default Value Enable state Enabled (globally and on all ports) Spanning-tree mode RSTP (Classic STP and MSTP are disabled) Switch priority 32768 BPDU flooding Disabled PortFast mode Disabled PortFast BPDU filter Disabled Loop guard Disabled BPDU protection Disabled Spanning tree port priority 128 Maximum-aging time 20 seconds Forward-delay time 15 seconds Maximum hops 20 Spanning-tree transmit hold count 6 MSTP region name MAC address of switch MSTP included VLANs 1 Configuring the Spanning Tree Protocol 639 Configuring Spanning Tree (Web) This section provides information about the OpenManage Switch Administrator pages for configuring and monitoring STP settings on a PowerConnect 7000 Series switch. For details about the fields on a page, click at the top of the page. STP Global Settings The STP Global Settings page contains fields for enabling STP on the switch. To display the STP Global Settings page, click Switching → Spanning Tree → Global Settings in the navigation panel. Figure 22-5. Spanning Tree Global Settings 640 Configuring the Spanning Tree Protocol STP Port Settings Use the STP Port Settings page to assign STP properties to individual ports. To display the STP Port Settings page, click Switching → Spanning Tree → STP Port Settings in the navigation panel. Figure 22-6. STP Port Settings Configuring the Spanning Tree Protocol 641 Configuring STP Settings for Multiple Ports To configure STP settings for multiple ports: 1 Open the STP Port Settings page. 2 Click Show All to display the STP Port Table. Figure 22-7. Configure STP Port Settings 3 For each port to configure, select the check box in the Edit column in the row associated with the port. 4 Select the desired settings. 5 Click Apply. 642 Configuring the Spanning Tree Protocol STP LAG Settings Use the STP LAG Settings page to assign STP aggregating ports parameters. To display the STP LAG Settings page, click Switching → Spanning Tree → STP LAG Settings in the navigation panel. Figure 22-8. STP LAG Settings Configuring STP Settings for Multiple LAGs To configure STP settings on multiple LAGS: 1 Open the STP LAG Settings page. 2 Click Show All to display the STP LAG Table. Configuring the Spanning Tree Protocol 643 Figure 22-9. Configure STP LAG Settings 3 For each LAG to configure, select the check box in the Edit column in the row associated with the LAG. 4 Select the desired settings. 5 Click Apply. Rapid Spanning Tree Rapid Spanning Tree Protocol (RSTP) detects and uses network topologies that allow a faster convergence of the spanning tree without creating forwarding loops. To display the Rapid Spanning Tree page, click Switching → Spanning Tree → Rapid Spanning Tree in the navigation panel. Figure 22-10. 644 Rapid Spanning Tree Configuring the Spanning Tree Protocol To view RSTP Settings for all interfaces, click the Show All link. The Rapid Spanning Tree Table displays. Figure 22-11. RSTP LAG Settings Configuring the Spanning Tree Protocol 645 MSTP Settings The Multiple Spanning Tree Protocol (MSTP) supports multiple instances of Spanning Tree to efficiently channel VLAN traffic over different interfaces. MSTP is compatible with both RSTP and STP; a MSTP bridge can be configured to behave entirely as a RSTP bridge or a STP bridge. To display the MSTP Settings page, click Switching → Spanning Tree → MSTP Settings in the navigation panel. Figure 22-12. 646 MSTP Settings Configuring the Spanning Tree Protocol Viewing and Modifying the Instance ID for Multiple VLANs To configure MSTP settings for multiple VLANS: 1 Open the MSTP Settings page. 2 Click Show All to display the MSTP Settings Table. Figure 22-13. Configure MSTP Settings 3 For each Instance ID to modify, select the check box in the Edit column in the row associated with the VLAN. 4 Update the Instance ID settings for the selected VLANs. 5 Click Apply. Configuring the Spanning Tree Protocol 647 MSTP Interface Settings Use the MSTP Interface Settings page to assign MSTP settings to specific interfaces. To display the MSTP Interface Settings page, click Switching → Spanning Tree → MSTP Interface Settings in the navigation panel. Figure 22-14. MSTP Interface Settings Configuring MSTP Settings for Multiple Interfaces To configure MSTP settings for multiple interfaces: 1 Open the MSTP Interface Settings page. 2 Click Show All to display the MSTP Interface Table. 648 Configuring the Spanning Tree Protocol Figure 22-15. Configure MSTP Interface Settings 3 For each interface to configure, select the check box in the Edit column in the row associated with the interface. 4 Update the desired settings. 5 Click Apply. Configuring the Spanning Tree Protocol 649 Configuring Spanning Tree (CLI) This section provides information about the commands you use to configure STP settings on the switch. For more information about the commands, see the PowerConnect 7000 Series CLI Reference Guide at support.dell.com/manuals. Configuring Global STP Bridge Settings Beginning in Privileged EXEC mode, use the following commands to configure the global STP settings for the switch, such as the priority and timers. Command Purpose configure Enter global configuration mode. spanning-tree Enable spanning tree on the switch. spanning tree mode {stp Specify which spanning tree mode to use on the switch. | rstp |mst} spanning-tree priority Specify the priority of the bridge. (Range: 0–61440). The switch with the lowest priority value is elected as the root switch. spanning-tree max-age Specify the switch maximum age time, which indicates the amount of time in seconds a bridge waits before implementing a topological change. Valid values are from (6 to 40) seconds. spanning-tree forwardtime seconds Specify the switch forward delay time, which indicates the amount of time in seconds a bridge remains in a listening and learning state before forwarding packets. Valid values are from (4 to 30) seconds. priority seconds spanning-tree max-hops Configure the maximum number of hops for the Spanning tree. Valid values are from (6 to 40). hops spanning-tree transmit hold-count [value] Set the maximum number of BPDUs that a bridge is allowed to send within a hello time window (2 seconds). The range for value is 1–10. CTRL + Z Exit to Privileged EXEC mode. 650 Configuring the Spanning Tree Protocol Command Purpose show spanning-tree [detail] [active | blockedports] View information about spanning tree and the spanning tree configuration on the switch. Configuring Optional STP Features Beginning in Privileged EXEC mode, use the following commands to configure the optional STP features on the switch or on specific interfaces. Command Purpose configure Enter global configuration mode. spanning-tree bpdu flooding Allow the flooding of BPDUs received on non-spanningtree ports to all other non-spanning-tree ports. spanning-tree portfast Enable PortFast on all switch ports. spanning-tree portfast bpdufilter default Prevent ports configured in PortFast mode from sending BPDUs. spanning-tree loopguard Enable loop guard on all ports. default spanning-tree bpduprotection Enable BPDU protection on the switch. interface interface Enter interface configuration mode for the specified interface. The interface variable includes the interface type and number, for example gigabitethernet 1/0/3 or portchannel 4. You can also specify a range of interfaces with the interface range command, for example, interface range gigabitethernet 1/0/8-12 configures interfaces 8, 9, 10, 11, and 12. The range keyword is also valid for LAGs (port channels). spanning-tree autoportfast Set the port to auto portfast mode. This enables the port to become a portfast port if it does not see any BPDUs for 3 seconds. spanning-tree guard {root | loop | none} Enable loop guard or root guard (or disable both) on the interface. Configuring the Spanning Tree Protocol 651 Command Purpose spanning-tree tcnguard Prevent the port from propagating topology change notifications. CTRL + Z Exit to Privileged EXEC mode. show spanning-tree summary View various spanning tree settings and parameters for the switch. Configuring STP Interface Settings Beginning in Privileged EXEC mode, use the following commands to configure the STP settings for a specific interface. Command Purpose configure Enter global configuration mode. interface interface Enter interface configuration mode for the specified interface. The interface variable includes the interface type and number, for example gigabitethernet 1/0/3 or portchannel 4. You can also specify a range of interfaces with the interface range command, for example, interface range gigabitethernet 1/0/8-12 configures interfaces 8, 9, 10, 11, and 12. The range keyword is also valid for LAGs (port channels). spanning-tree disable Disable spanning-tree on the port. spanning-tree portpriority priority Specify the priority of the port. (Range: 0–240). spanning-tree cost cost Specify the spanning-tree path cost for the port. (Range: 0–200,000,000). The default cost is 0, which signifies that the cost is automatically calculated based on port speed. CTRL + Z Exit to Privileged EXEC mode. show spanning-tree View spanning tree configuration information for the specified port or LAG (port channel). interface 652 The priority value is used to determine which ports are put in the forwarding state and which ports are put in the blocking state. A port with a lower priority value is more likely to be put into a forwarding state. Configuring the Spanning Tree Protocol Configuring MSTP Switch Settings Beginning in Privileged EXEC mode, use the following commands to configure MSTP settings for the switch. Command Purpose configure Enter global configuration mode. spanning-tree mst configuration Enable configuring an MST region by entering the multiple spanning-tree (MST) mode. name string Define the MST configuration name revision version Identify the MST configuration revision number. instance instance-id {add | remove} vlan Map VLANs to an MST instance. vlan-range • instance-ID — ID of the MST instance. (Range: 1-4094) • vlan-range — VLANs to be added to the existing MST instance. To specify a range of VLANs, use a hyphen. To specify a series of VLANs, use a comma. (Range: 1-4093) exit Return to global configuration mode. spanning-tree mst instance-id priority Set the switch priority for the specified spanning-tree instance. priority • instance-id — ID of the spanning-tree instance. (Range: 1-4094) • priority — Sets the switch priority for the specified spanning-tree instance. This setting affects the likelihood that the switch is selected as the root switch. A lower value increases the probability that the switch is selected as the root switch. (Range: 0-61440) CTRL + Z Exit to Privileged EXEC mode. show spanning-tree mst- View multiple spanning tree configuration information. configuration show spanning-tree instance instance-id View information about the specified MSTI. Configuring the Spanning Tree Protocol 653 Configuring MSTP Interface Settings Beginning in Privileged EXEC mode, use the following commands to configure MSTP settings for the switch. Command Purpose configure Enter global configuration mode. interface interface Enter interface configuration mode for the specified interface. The interface variable includes the interface type and number, for example gigabitethernet 1/0/3 or port-channel 4. You can also specify a range of interfaces with the interface range command, for example, interface range gigabitethernet 1/0/8-12 configures interfaces 8, 9, 10, 11, and 12. The range keyword is also valid for LAGs (port channels). spanning-tree mst 0 Set the external cost for the common spanning tree. (Range: 0–200000000) external-cost cost spanning-tree mst Configure the path cost for MST calculations. If a loop occurs, instance-id cost cost the spanning tree considers path cost when selecting an interface to put in the forwarding state. • instance-ID — ID of the spanning -tree instance. (Range: 14094) • cost — The port path cost. (Range: 0–200,000,000) spanning-tree mst instance-id portpriority priority Specify the priority of the port. The priority value is used to determine which ports are put in the forwarding state and which ports are put in the blocking state. A port with a lower priority value is more likely to be put into a forwarding state. • instance-ID — ID of the spanning-tree instance. (Range: 14094) • priority — The port priority. (Range: 0–240 in multiples of 16) CTRL + Z Exit to Privileged EXEC mode. show spanning-tree interface instance View MST configuration information for the specified port or LAG (port channel) and instance. instance-id 654 Configuring the Spanning Tree Protocol STP Configuration Examples This section contains the following examples: • Configuring STP • Configuring MSTP Configuring STP This example shows a LAN with four switches. On each switch, ports 1, 2, and 3 connect to other switches, and ports 4–20 connect to hosts (in Figure 22-16, each PC represents 17 host systems). Figure 22-16. STP Example Network Diagram Configuring the Spanning Tree Protocol 655 Of the four switches in Figure 22-16, the administrator decides that Switch A is the most centrally located in the network and is the least likely to be moved or redeployed. For these reasons, the administrator selects it as the root bridge for the spanning tree. The administrator configures Switch A with the highest priority and uses the default priority values for Switch B, Switch C, and Switch D. For all switches, the administrator also configures ports 4–17 in Port Fast mode because these ports are connected to hosts and can transition directly to the Forwarding state to speed up the connection time between the hosts and the network. The administrator also configures Port Fast BPDU filtering and Loop Guard to extend STP’s capability to prevent network loops. For all other STP settings, the administrator uses the default STP values. To configure the switch: 1 Connect to Switch A and configure the priority to be higher (a lower value) than the other switches, which use the default value of 32768. console#config console(config)#spanning-tree priority 8192 2 Configure ports 4–20 to be in Port Fast mode. console(config)#interface range gi1/0/4-20 console(config-if)#spanning-tree portfast console(config-if)#exit 3 Enable Loop Guard on ports 1–3 to help prevent network loops that might be caused if a port quits receiving BPDUs. console(config)#interface range gi1/0/1-3 console(config-if)#spanning-tree guard loop console(config-if)#exit 4 Enable Port Fast BPDU Filter. This feature is configured globally, but it affects only Port Fast-enabled access ports. console(config)#spanning-tree portfast bpdufilter default 5 Repeat step 2 through step 4 on Switch B, Switch C, and Switch D to complete the configuration. 656 Configuring the Spanning Tree Protocol Configuring MSTP This example shows how to configure IEEE 802.1s Multiple Spanning Tree (MST) protocol on the switches shown in Figure 22-17. Figure 22-17. MSTP Configuration Example To make multiple switches be part of the same MSTP region, make sure the STP operational mode for all switches is MSTP. Also, make sure the MST region name and revision level are the same for all switches in the region. To configure the switches: 1 Create VLAN 10 (Switch A and Switch B) and VLAN 20 (all switches). NOTE: Even Switch B does not have any ports that are members of VLAN 10, this VLAN must be created to allow the formation of MST regions made up of all bridges that exchange the same MST Configuration Identifier. It is only within these MST Regions that multiple instances can exist. console#configure console(config)#vlan 10,20 console(config-vlan10,20)#exit console(config-vlan)#exit Configuring the Spanning Tree Protocol 657 2 Set the STP operational mode to MSTP. console(config)#spanning-tree mode mst 3 Create MST instance 10 and associate it to VLAN 10. console(config)#spanning-tree mst configuration console(config-mst)#instance 10 add vlan 10 4 Create MST instances 20 and associate it to VLAN 20. console(config-mst)#instance 20 add vlan 20 5 Change the region name so that all the bridges that want to be part of the same region can form the region. console(config-mst)#name dell console(config-mst)#exit 6 (Switch A only) Configure Switch A to be the root bridge of the spanning tree (CIST Regional Root) by configuring a higher root bridge priority. console(config)#spanning-tree priority 8192 7 (Switch A only) Make Switch A the Regional Root for MSTI 1 by configuring a higher priority for MST ID 10. console(config)#spanning-tree mst 10 priority 12288 8 (Switch A only) Change the priority of MST ID 20 to ensure Switch C is the Regional Root bridge for this MSTI. console(config)#spanning-tree mst 20 priority 61440 console(config)#spanning-tree priority 8192 9 (Switch C only) Change the priority of port 1 to force it to be the root port for MST 20. console(config)#interface gi1/0/1 console(config-if-Gi1/0/1)#spanning-tree mst 20 port-priority 64 console(config-if-Gi1/0/1)#exit 658 Configuring the Spanning Tree Protocol 23 Discovering Network Devices This chapter describes the Industry Standard Discovery Protocol (ISDP) feature and the Link Layer Discovery Protocol (LLDP) feature, including LLDP for Media Endpoint Devices (LLDP-MED). The topics covered in this chapter include: • Device Discovery Overview • Default IDSP and LLDP Values • Configuring ISDP and LLDP (Web) • Configuring ISDP and LLDP (CLI) • Device Discovery Configuration Examples Device Discovery Overview The switch software includes two different device discovery protocols: IDSP and LLDP. These protocols allow the switch to broadcast information about itself and to learn information about neighboring devices. What Is ISDP? The Industry Standard Discovery Protocol (ISDP) is a proprietary Layer 2 network protocol that inter-operates with Cisco devices running the Cisco Discovery Protocol (CDP). ISDP is used to share information between neighboring devices. The switch software participates in the CDP protocol and is able to both discover and be discovered by other CDP-supporting devices. What is LLDP? LLDP is a standardized discovery protocol defined by IEEE 802.1AB. It allows stations residing on an 802 LAN to advertise major capabilities physical descriptions, and management information to physically adjacent devices allowing a network management system (NMS) to access and display this information. Discovering Network Devices 659 LLDP is a one-way protocol; there are no request/response sequences. Information is advertised by stations implementing the transmit function, and is received and processed by stations implementing the receive function. The transmit and receive functions can be enabled/disabled separately on each switch port. What is LLDP-MED? LLDP-MED is an extension of the LLDP standard. LLDP-MED uses LLDP's organizationally-specific Type- Length-Value (TLV) extensions and defines new TLVs that make it easier for a VoIP deployment in a wired or wireless LAN/MAN environment. It also makes mandatory a few optional TLVs from LLDP and recommends not transmitting some TLVs. The TLVs only communicate information; these TLVs do not automatically translate into configuration. An external application may query the MED MIB and take management actions in configuring functionality. Why are Device Discovery Protocols Needed? The device discovery protocols are used primarily in conjunction with network management tools to provide information about network topology and configuration, and to help troubleshoot problems that occur on the network. The discovery protocols can also facilitate inventory management within a company. LLDP and the LLDP-MED extension are vendor-neutral discovery protocols that can discover devices made by numerous vendors. LLDP-MED is intended to be used on ports that connect to VoIP phones. Additional applications for LLDP-MED include device location (including for Emergency Call Service/E911) and Power over Ethernet management. ISDP interoperates with the Cisco-proprietary CDP protocol and is most effective in an environment that contains many Cisco devices. 660 Discovering Network Devices Default IDSP and LLDP Values ISDP and LLDP are globally enabled on the switch and enabled on all ports by default. By default, the switch transmits and receives LLDP information on all ports. LLDP-MED is disabled on all ports. Table 23-1 summarizes the default values for ISDP. Table 23-1. ISDP Defaults Parameter Default Value ISDP Mode Enabled (globally and on all ports) ISDPv2 Mode Enabled (globally and on all ports) Message Interval 30 seconds Hold Time Interval 180 seconds Device ID none Device ID Format Capability Serial Number, Host Name Device ID Format Serial Number Table 23-2 summarizes the default values for LLDP. Table 23-2. LLDP Defaults Parameter Default Value Transmit Mode Enabled on all ports Receive Mode Enabled on all ports Transmit Interval 30 seconds Hold Multiplier 4 Reinitialization Delay 2 seconds Notification Interval 5 seconds Transmit Management Information Disabled Notification Mode Disabled Included TLVs None Discovering Network Devices 661 Table 23-3 summarizes the default values for LLDP-MED. Table 23-3. LLDP-MED Defaults Parameter Default Value LLDP-MED Mode Disabled on all ports Config Notification Mode Disabled on all ports Transmit TVLs MED Capabilities Network Policy 662 Discovering Network Devices Configuring ISDP and LLDP (Web) This section provides information about the OpenManage Switch Administrator pages for configuring and monitoring IDSP and LLDP/LLDPMED on a PowerConnect 7000 Series switch. For details about the fields on a page, click at the top of the page. ISDP Global Configuration From the ISDP Global Configuration page, you can configure the ISDP settings for the switch, such as the administrative mode. To access the ISDP Global Configuration page, click System → ISDP → Global Configuration in the navigation panel. Figure 23-1. ISDP Global Configuration Discovering Network Devices 663 ISDP Cache Table From the ISDP Cache Table page, you can view information about other devices the switch has discovered through the ISDP. To access the ISDP Cache Table page, click System → ISDP → Cache Table in the navigation panel. Figure 23-2. ISDP Cache Table 664 Discovering Network Devices ISDP Interface Configuration From the ISDP Interface Configuration page, you can configure the ISDP settings for each interface. If ISDP is enabled on an interface, it must also be enabled globally in order for the interface to transmit ISDP packets. If the ISDP mode on the ISDP Global Configuration page is disabled, the interface will not transmit ISDP packets, regardless of the mode configured on the interface. To access the ISDP Interface Configuration page, click System → ISDP → Interface Configuration in the navigation panel. Figure 23-3. ISDP Interface Configuration Discovering Network Devices 665 To view view the ISDP mode for multiple interfaces, click Show All. Figure 23-4. ISDP Interface Summary 666 Discovering Network Devices ISDP Statistics From the ISDP Statistics page, you can view information about the ISDP packets sent and received by the switch. To access the ISDP Statistics page, click System → ISDP → Statistics in the navigation panel. Figure 23-5. ISDP Statistics Discovering Network Devices 667 LLDP Configuration Use the LLDP Configuration page to specify LLDP parameters. Parameters that affect the entire system as well as those for a specific interface can be specified here. To display the LLDP Configuration page, click Switching → LLDP → Configuration in the navigation panel. Figure 23-6. LLDP Configuration 668 Discovering Network Devices To view the LLDP Interface Settings Table, click Show All. From the LLDP Interface Settings Table page, you can view and edit information about the LLDP settings for multiple interfaces. Figure 23-7. LLDP Interface Settings Table Discovering Network Devices 669 LLDP Statistics Use the LLDP Statistics page to view LLPD-related statistics. To display the LLDP Statistics page, click Switching → LLDP → Statistics in the navigation panel. Figure 23-8. LLDP Statistics 670 Discovering Network Devices LLDP Connections Use the LLDP Connections page to view the list of ports with LLDP enabled. Basic connection details are displayed. To display the LLDP Connections page, click Switching → LLDP → Connections in the navigation panel. Figure 23-9. LLDP Connections Discovering Network Devices 671 To view additional information about a device connected to a port that has been discovered through LLDP, click the port number in the Local Interface table (it is a hyperlink), or click Details and select the port with the connected device. Figure 23-10. 672 LLDP Connection Detail Discovering Network Devices LLDP-MED Global Configuration Use the LLDP-MED Global Configuration page to change or view the LLDP-MED parameters that affect the entire system. To display the LLDP-MED Global Configuration page, click Switching→ LLDP → LLDP-MED → Global Configuration in the navigation panel. Figure 23-11. LLDP-MED Global Configuration Discovering Network Devices 673 LLDP-MED Interface Configuration Use the LLDP-MED Interface Configuration page to specify LLDP-MED parameters that affect a specific interface. To display the LLDP-MED Interface Configuration page, click Switching → LLDP → LLDP-MED → Interface Configuration in the navigation panel. Figure 23-12. 674 LLDP-MED Interface Configuration Discovering Network Devices To view the LLDP-MED Interface Summary table, click Show All. Figure 23-13. LLDP-MED Interface Summary Discovering Network Devices 675 LLDP-MED Local Device Information Use the LLDP-MED Local Device Information page to view the advertised LLDP local data for each port. To display the LLDP-MED Local Device Information page, click Switching→ LLDP→ LLDP-MED→ Local Device Information in the navigation panel. Figure 23-14. 676 LLDP-MED Local Device Information Discovering Network Devices LLDP-MED Remote Device Information Use the LLDP-MED Remote Device Information page to view the advertised LLDP data advertised by remote devices. To display the LLDP-MED Remote Device Information page, click Switching→ LLDP→ LLDP-MED→ Remote Device Information in the navigation panel. Figure 23-15. LLDP-MED Remote Device Information Discovering Network Devices 677 Configuring ISDP and LLDP (CLI) This section provides information about the commands you use to manage and view the device discovery protocol features on the switch. For more information about these commands, see the PowerConnect 7000 Series CLI Reference Guide at support.dell.com/manuals. Configuring Global ISDP Settings Beginning in Privileged EXEC mode, use the following commands to configure ISDP settings that affect the entire switch. Command Purpose configure Enter Global Configuration mode. isdp enable Administratively enable ISDP on the switch. isdp advertise-v2 Allow the switch to send ISDPv2 packets. isdp holdtime time Specify the number of seconds the device that receives ISDP packets from the switch should store information sent in the ISDP packet before discarding it. isdp timer time Specify the number of seconds to wait between sending new ISDP packets. exit Exit to Privileged EXEC mode. show isdp View global ISDP settings. 678 Discovering Network Devices Enabling ISDP on a Port Beginning in Privileged EXEC mode, use the following commands to enable ISDP on a port. Command Purpose configure Enter Global Configuration mode. interface interface Enter interface configuration mode for the specified interface. isdp enable Administratively enable ISDP on the switch. exit Exit to Global Config mode. exit Exit to Privileged Exec mode. show isdp interface all View the ISDP mode on all interfaces. Viewing and Clearing ISDP Information Beginning in Privileged EXEC mode, use the following commands to view and clear the contents of the ISDP table and to view and clear ISDP statistics. Command Purpose deviceid} show isdp entry {all | View information about all entries or a specific entry in the ISDP table. show isdp neighbors View the neighboring devices discovered through ISDP. clear isdp table Clear all entries, including discovered neighbors, from the ISDP table. show isdp traffic View ISDP statistics. clear isdp counters Reset all ISDP statistics to zero. Discovering Network Devices 679 Configuring Global LLDP Settings Beginning in Privileged EXEC mode, use the following commands to configure LLDP settings that affect the entire switch. Command Purpose configure Enter Global Configuration mode. lldp notificationinterval interval Specify how often, in seconds, the switch should send remote data change notifications. lldp timers [interval Configure the timing for local data transmission on ports transmit-interval] [hold enabled for LLDP. hold-value] [reinit reinit- • transmit-interval — The interval in seconds at which to delay] transmit local data LLDP PDUs. (Range: 5–32768 seconds) • hold-value — Multiplier on the transmit interval used to set the TTL in local data LLDP PDUs. (Range: 2–10) • reinit-delay — The delay in seconds before reinitialization. (Range: 1–10 seconds) exit Exit to Privileged EXEC mode. show lldp View global LLDP settings. Configuring Port-based LLDP Settings Beginning in Privileged EXEC mode, use the following commands to configure per-port LLDP settings. Command Purpose configure Enter Global Configuration mode. interface interface Enter interface configuration mode for the specified Ethernet interface. lldp transmit Enable the LLDP advertise (transmit) capability. lldp receive Enable the LLDP receive capability so that the switch can receive LLDP Protocol Data Units (LLDP PDUs) from other devices. lldp transmit-mgmt Include the transmission of local system management address information in the LLDP PDUs. 680 Discovering Network Devices Command Purpose lldp notification Enable remote data change notifications on the interface. lldp transmit-tlv [sysdesc][sys-name][syscap][port-desc] Specify which optional type-length-value settings (TLVs) in the 802.1AB basic management set will be transmitted in the LLDP PDUs. • sys-name — Transmits the system name TLV • sys-desc — Transmits the system description TLV • sys-cap — Transmits the system capabilities TLV • port desc — Transmits the port description TLV exit Exit to Global Config mode. exit Exit to Privileged EXEC mode. show lldp interface all View LLDP settings for all interfaces. Viewing and Clearing LLDP Information Beginning in Privileged EXEC mode, use the following commands to view transmitted and received LLDP information and to view and clear LLDP statistics. Command Purpose show lldp local-device {all | interface | detail interface} View LLDP information advertised by all ports or the specified port. Include the keyword detail to see additional information. show lldp remote-device View LLDP information received by all ports or by the {all | interface | detail specified port. Include the keyword detail to see additional interface} information. clear lldp remote-data Delete all LLDP information from the remote data table. show lldp statistics View LLDP traffic statistics. clear lldp statistics Reset the LLDP statistics counters to zero. Discovering Network Devices 681 Configuring LLDP-MED Settings Beginning in Privileged EXEC mode, use the following commands to configure LLDP-MED settings that affect the entire switch. Command Purpose configure Enter Global Configuration mode. lldp med faststartrepeatcount Specifies the number of LLDP PDUs that will be transmitted when the protocol is enabled. interface interface Enter interface configuration mode for the specified Ethernet interface. lldp med Enable LLDP-MED on the interface. lldp med confignotification Allow the port to send topology change notifications. count lldp med transmit-tlv Specify which optional TLVs in the LLDP MED set are [capabilities] [network- transmitted in the LLDP PDUs. policy] [location] [inventory] exit Exit to Global Config mode. exit Exit to Privileged EXEC mode. show lldp med View global LLDP-MED settings. show lldp med interface View LLDP-MED settings for all ports or for the specified {all | interface} port. 682 Discovering Network Devices Viewing LLDP-MED Information Beginning in Privileged EXEC mode, use the following commands to view information about the LLDP-MED Protocol Data Units (PDUs) that are sent and have been received. Command Purpose show lldp med localdevice detail interface View LLDP information advertised by the specified port. show lldp remote-device View LLDP-MED information received by all ports or by {all | interface | detail the specified port. Include the keyword detail to see interface} additional information. Device Discovery Configuration Examples This section contains the following examples: • Configuring ISDP • Configuring LLDP Configuring ISDP This example shows how to configure ISDP settings on the switch. To configure the switch: 1 Specify the number of seconds that a remote device should keep the ISDP information sent by the switch before discarding it. console#configure console(config)#isdp holdtime 60 2 Specify how often, in seconds, the ISDP-enabled ports should transmit information. console(config)#isdp timer 45 3 Enable ISDP on interface 1/0/3. console(config)#interface gigabitEthernet1/0/3 console(config-if-Gi1/0/3)#isdp enable Discovering Network Devices 683 4 Exit to Privileged EXEC mode and view the LLDP settings for the switch and for interface 1/0/3. console(config-if-Gi1/0/3)# console#show isdp Timer....................................45 Hold Time................................60 Version 2 Advertisements.................Enabled Neighbors table time since last change...00 days 00:00:00 Device ID................................none Device ID format capability........ Serial Number, Host Name Device ID format.................. Serial Number console#show isdp interface gi1/0/3 Interface --------------Gi1/0/3 Mode ---------Enabled Configuring LLDP This example shows how to configure LLDP settings for the switch and to allow Gigabit Ethernet port 1/0/3 to transmit all LLDP information available. To configure the switch: 1 Configure the transmission interval, hold multiplier, and reinitialization delay for LLDP PDUs sent from the switch. console#configure console(config)#lldp timers interval 60 hold 5 reinit 3 2 Enable port 1/0/3 to transmit and receive LLDP PDUs. console(config)#interface gigabitEthernet1/0/3 console(config-if-Gi1/0/3)#lldp transmit console(config-if-Gi1/0/3)#lldp receive 684 Discovering Network Devices 3 Enable port 1/0/3 to transmit management address information in the LLDP PDUs and to send topology change notifications if a device is added or removed from the port. console(config-if-Gi1/0/3)#lldp transmit-mgmt console(config-if-Gi1/0/3)#lldp notification 4 Specify the TLV information to be included in the LLDP PDUs transmitted from port 1/0/3. console(config-if-Gi1/0/3)#lldp transmit-tlv sysname sys-desc sys-cap port-desc 5 Set the port description to be transmitted in LLDP PDUs. console(config-if-Gi1/0/3)#description “Test Lab Port” 6 Exit to Privileged EXEC mode. console(config-if-Gi1/0/3)# 7 View global LLDP settings on the switch. console#show lldp LLDP Global Configuration Transmit Interval..................... Transmit Hold Multiplier.............. Reinit Delay.......................... Notification Interval................. 60 seconds 5 3 seconds 5 seconds 8 View summary information about the LLDP configuration on port 1/0/3. console#show lldp interface gi1/0/3 LLDP Interface Configuration Interface --------Gi1/0/3 Link -----Down Transmit -------Enabled Receive -------Enabled Notify -------Enabled TLVs ------0,1,2,3 Mgmt ---Y TLV Codes: 0- Port Description, 1- System Name 2- System Description, 3- System Capabilities Discovering Network Devices 685 9 View detailed information about the LLDP configuration on port 1/0/3. console#show lldp local-device detail gi1/0/3 LLDP Local Device Detail Interface: Gi1/0/3 Chassis ID Subtype: MAC Address Chassis ID: 00:1E:C9:AA:AA:07 Port ID Subtype: Interface Name Port ID: gi 1/0/3 System Name: console System Description: PowerConnect 7048 3.16.22.30, VxWorks 6.5 Port Description: Test Lab Port System Capabilities Supported: bridge, router System Capabilities Enabled: bridge Management Address: Type: IPv4 Address: 192.168.2.1 686 Discovering Network Devices 24 Configuring Port-Based Traffic Control This chapter describes how to configure features that provide traffic control through filtering the type of traffic or limiting the speed or amount of traffic on a per-port basis. The features this section describes includes flow control, storm control, protected ports, and Link Local Protocol Filtering (LLPF), which is also known as Cisco Protocol Filtering. The topics covered in this chapter include: • Port-Based Traffic Control Overview • Default Port-Based Traffic Control Values • Configuring Port-Based Traffic Control (Web) • Configuring Port-Based Traffic Control (CLI) • Port-Based Traffic Control Configuration Example Port-Based Traffic Control Overview Table 24-1 provides a summary of the features this chapter describes. Table 24-1. Port-Based Traffic Control Features Feature Description Flow control Allows traffic transmission between a switch port and another Ethernet device to be paused for a specified period of time when congestion occurs. Storm control Limits the amount of broadcast, unknown unicast, and multicast frames accepted and forwarded by the switch. Protected ports Prevents traffic from flowing between members of the same protected port group. LLPF Filters proprietary protocols that should not normally be relayed by a bridge. Configuring Port-Based Traffic Control 687 What is Flow Control? IEEE 802.3 Annex 31B flow control allows nodes that transmit at slower speeds to communicate with higher speed switches by requesting that the higher speed switch refrain from sending packets. Transmissions are temporarily halted to prevent buffer overflows. Enabling the flow control feature allows PowerConnect 7000 Series switches to process pause frames received from connected devices. PowerConnect switches do not transmit pause frames. Flow control is supported only on ports that are configured for full-duplex mode of operation. Since ports set to auto negotiate may not be added as LAG members, LAG member ports cannot have flow control configured to auto. What is Storm Control? A LAN storm is the result of an excessive number of broadcast, multicast, or unknown unicast messages simultaneously transmitted across a network by a single port. Forwarded message responses can overload network resources and cause network congestion. The storm control feature allows the switch to measure the incoming broadcast, multicast, and/or unknown unicast packet rate per port and discard packets when the rate exceeds the defined threshold. Storm control is enabled per interface, by defining the packet type and the rate at which the packets are transmitted. For each type of traffic (broadcast, multicast, or unknown unicast) you can configure a threshold level, which is expressed as a percentage of the total available bandwidth on the port. If the ingress rate of that type of packet is greater than the configured threshold level the port drops the excess traffic until the ingress rate for the packet type falls below the threshold. The actual rate of ingress traffic required to activate storm-control is based on the size of incoming packets and the hard-coded average packet size of 512 bytes - used to calculate a packet-per-second (pps) rate - as the forwardingplane requires PPS versus an absolute rate Kbps. For example, if the configured limit is 10%, this is converted to ~25000 PPS, and this PPS limit is set in the hardware. You get the approximate desired output when 512 bytes packets are used. 688 Configuring Port-Based Traffic Control What are Protected Ports? The switch supports up to three separate groups of protected ports. Traffic can flow between protected ports belonging to different groups, but not within the same group. A port can belong to only one protected port group. You must remove an interface from one group before adding it to another group. Port protection occurs within a single switch. Protected port configuration does not affect traffic between ports on two different switches. No traffic forwarding is possible between two protected ports. What is Link Local Protocol Filtering? The Link Local Protocol Filtering (LLPF) feature can help troubleshoot network problems that occur when a network includes proprietary protocols running on standards-based switches. LLPF allows a PowerConnect 7000 Series switch to filter out various Cisco proprietary protocol data units (PDUs) and/or ISDP if problems occur with these protocols running on standards-based switches. If certain protocol PDUs cause unexpected results, LLPF can be enabled to prevent those protocol PDUs from being processed by the switch. The LLPF feature can be configured per-port to block any combination (or all) of the following PDUs: • Industry Standard Discovery Protocol (ISDP) • VLAN Trunking Protocol (VTP) • Dynamic Trunking Protocol (DTP) • UniDirectional Link Detection (UDLD) • Port Aggregation Protocol (PAgP) • Shared Spanning Tree Protocol (SSTP) Access Control Lists (ACLs) and LLPF can exist on the same interface. However, the ACL rules override the LLPF rules when there is a conflict. Similarly, DiffServ and LLPF can both be enabled on an interface, but DiffServ rules override LLPF rules when there is a conflict. Configuring Port-Based Traffic Control 689 If Industry Standard Discovery Protocol (ISDP) is enabled on an interface, and the LLPF feature on an interface is enabled and configured to drop ISDP PDUs, the ISDP configuration overrides the LLPF configuration, and the ISDP PDUs are allowed on the interface. Default Port-Based Traffic Control Values Table 24-2 lists the default values for the port-based traffic control features that this chapter describes. Table 24-2. Default Port-Based Traffic Control Values Feature Default Flow control Enabled Storm control Disabled Protected ports None LLPF No protocols are blocked 690 Configuring Port-Based Traffic Control Configuring Port-Based Traffic Control (Web) This section provides information about the OpenManage Switch Administrator pages to use to control port-based traffic on a PowerConnect 7000 Series switch. For details about the fields on a page, click at the top of the page. Flow Control (Global Port Parameters) Use the Global Parameters page for ports to enable or disable flow control support on the switch. To display the Global Parameters page, click Switching → Ports → Global Parameters in the navigation menu. Figure 24-1. Global Port Parameters Configuring Port-Based Traffic Control 691 Storm Control Use the Storm Control page to enable and configure the storm control feature. To display the Storm Control interface, click Switching → Ports → Storm Control in the navigation menu. Figure 24-2. Storm Control Configuring Storm Control Settings on Multiple Ports To configure storm control on multiple ports: 1 Open the Storm Control page. 2 Click Show All to display the Storm Control Settings Table. 3 In the Ports list, select the check box in the Edit column for the port to configure. 4 Select the desired storm control settings. 692 Configuring Port-Based Traffic Control Figure 24-3. Storm Control 5 Click Apply. Configuring Port-Based Traffic Control 693 Protected Port Configuration Use the Protected Port Configuration page to prevent ports in the same protected ports group from being able to see each other’s traffic. To display the Protected Port Configuration page, click Switching → Ports → Protected Port Configuration in the navigation menu. Figure 24-4. Protected Port Configuration Configuring Protected Ports To configure protected ports: 1 Open the Protected Ports page. 2 Click Add to display the Add Protected Group page. 3 Select a group (0–2). 4 Specify a name for the group. 694 Configuring Port-Based Traffic Control Figure 24-5. Add Protected Ports Group 5 Click Apply. 6 Click Protected Port Configuration to return to the main page. 7 Select the port to add to the group. 8 Select the protected port group ID. Figure 24-6. Add Protected Ports 9 Click Apply. 10 To view protected port group membership information, click Show All. Configuring Port-Based Traffic Control 695 Figure 24-7. View Protected Port Information 11 To remove a port from a protected port group, select the Remove check box associated with the port and click Apply. LLPF Configuration Use the LLPF Interface Configuration page to filter out various proprietary protocol data units (PDUs) and/or ISDP if problems occur with these protocols running on standards-based switches. To display the LLPF Interface Configuration page, click Switching → Network Security → Proprietary Protocol Filtering → LLPF Interface Configuration the navigation menu. 696 Configuring Port-Based Traffic Control Figure 24-8. LLPF Interface Configuration To view the protocol types that have been blocked for an interface, click Show All. Figure 24-9. LLPF Filtering Summary Configuring Port-Based Traffic Control 697 Configuring Port-Based Traffic Control (CLI) This section provides information about the commands you use to configure port-based traffic control settings. For more information about the commands, see the PowerConnect 7000 Series CLI Reference Guide at support.dell.com/manuals. Configuring Flow Control and Storm Control Beginning in Privileged EXEC mode, use the following commands to configure the flow control and storm control features. Command Purpose configure Enter global configuration mode. flowcontrol Globally enable flow control. interface interface Enter interface configuration mode for the specified interface. The interface variable includes the interface type and number, for example gigabitethernet 1/0/3. You can also specify a range of interfaces with the interface range command, for example, interface range gigabitethernet 1/0/8-12 configures interfaces 8, 9, 10, 11, and 12. storm-control broadcast Enable broadcast storm recovery mode on the interface and (optionally) set the threshold. [level rate] rate — threshold as percentage of port speed. The percentage is converted to a PacketsPerSecond value based on a 512 byte average packet size. storm-control multicast Enable multicast storm recovery mode on the interface [level rate] and (optionally) set the threshold. rate — threshold as percentage of port speed. The percentage is converted to a PacketsPerSecond value based on a 512 byte average packet size. storm-control unicast [level rate] Enable unknown unicast storm recovery mode on the interface and (optionally) set the threshold. rate — threshold as percentage of port speed. The percentage is converted to a PacketsPerSecond value based on a 512 byte average packet size. 698 Configuring Port-Based Traffic Control Command Purpose CTRL + Z Exit to Privileged EXEC mode. show interfaces detail interface Display detailed information about the specified interface, including the flow control status. show storm-control View whether 802.3x flow control is enabled on the switch. show storm-control [interface | all] View storm control settings for all interfaces or the specified interface. Configuring Protected Ports Beginning in Privileged EXEC mode, use the following commands to add a name to a protected port group and add ports to the group. Command Purpose configure Enter global configuration mode. switchport protected groupid name name Specify a name for one of the three protected port groups. • groupid — Identifies which group the port is to be protected in. (Range: 0-2) • name — Name of the group. (Range: 0-32 characters) interface interface Enter interface configuration mode for the specified interface. The interface variable includes the interface type and number, for example gigabitethernet 1/0/3. switchport protected Add the interface to the specified protected port group. CTRL + Z Exit to Privileged EXEC mode. show switchport protected View protected group and port information. groupid Configuring Port-Based Traffic Control 699 Configuring LLPF Beginning in Privileged EXEC mode, use the following commands to configure LLPF settings. Command Purpose configure Enter global configuration mode. interface interface Enter interface configuration mode for the specified interface. The interface variable includes the interface type and number, for example gigabitethernet 1/0/3. You can also specify a range of interfaces with the interface range command, for example, interface range gigabitethernet 1/0/8-12 configures interfaces 8, 9, 10, 11, and 12. service-acl input Use the appropriate keyword, or combination of keywords {blockcdp | blockvtp | to block any (or all) of the following PDUs on the blockdtp | blockudld | interface: blockpagp | blocksstp | • VTP blockall} • DTP • UDLD • PAgP • SSTP • All CTRL + Z Exit to Privileged EXEC mode. show service-acl interface {interface | all} View information about the blocked PDUs on the specified interface or all interfaces. 700 Configuring Port-Based Traffic Control Port-Based Traffic Control Configuration Example The commands in this example configure storm control, LLPF, and protected port settings for various interfaces on the switch. The storm control configuration in this example sets thresholds on the switch so that if broadcast traffic occupies more than 10% on the bandwidth on any physical port, the interface blocks the broadcast traffic until the measured amount of this traffic drops below the threshold. The LLPF configuration in this example disables all PAgP and VTP PDUs from being forwarded on any switch port or LAG. The protected port configuration in this example prevents the clients connected to ports 3, 4, and 9 from being able to communicate with each other. To configure the switch: 1 Configure storm control for broadcast traffic on all physical interfaces. console(config)#interface range gi1/0/1-24 console(config-if)#storm-control broadcast level 10 2 Configure LLPF to block PAgP and VTP PDUs on all physical interfaces. console(config-if)#service-acl blockpagp blockvtp console(config-if)#exit 3 Specify a name for protected port group 0. console(config)#protected 0 name clients 4 Add the ports to the protected port group. console(config)#interface gi1/0/3 console(config-if-Gi1/0/3)#switchport protected 0 console(config-if-Gi1/0/3)#exit console(config)#interface gi1/0/4 console(config-if-Gi1/0/4)#switchport protected 0 console(config-if-Gi1/0/4)#exit console(config)#interface gi1/0/9 console(config-if-Gi1/0/9)#switchport protected 0 console(config-if-Gi1/0/9)#exit console(config)#exit Configuring Port-Based Traffic Control 701 5 Verify the configuration. console#show storm-control gi1/0/1 Bcast Bcast Mcast Mcast Ucast Ucast Intf Mode Level Mode Level Mode Level ------ ------- ------- ------- ------- ------- ------Gi1/0/1 Enable 10 Enable 5 Disable 5 console#show service-acl interface gi1/0/1 Protocol --------------CDP VTP DTP UDLD PAGP SSTP ALL Mode ---------Disabled Enabled Disabled Disabled Enabled Disabled Disabled console#show switchport protected 0 Name......................................... "clients" Member Ports: Gi1/0/1, Gi1/0/2, Gi1/0/3, Gi1/0/4, Gi1/0/9 702 Configuring Port-Based Traffic Control 25 Configuring L2 Multicast Features This chapter describes the layer 2 multicast features on the PowerConnect 7000 Series switches. The features this chapter describes include bridge multicast filtering, Internet Group Management Protocol (IGMP) snooping, Multicast Listener Discovery (MLD) snooping, and Multicast VLAN Registration (MVR). The topics covered in this chapter include: • L2 Multicast Overview • Snooping Switch Restrictions • Default L2 Multicast Values • Configuring L2 Multicast Features (Web) • Configuring L2 Multicast Features (CLI) • Case Study on a Real-World Network Topology L2 Multicast Overview Multicast traffic is traffic from one source that has multiple destinations. The L2 multicast features on the switch help control network flooding of Ethernet multicast and IP multicast traffic by keeping track of multicast group membership. It is essential that a multicast router be connected to a PowerConnect layer 2 multicast switch for IGMP/MLD snooping to operate properly. The presence of a multicast router allows the snooping switch to relay IGMP reports to the router and to forward multicast data sources to the multicast router as well as restrict flooding of multicast sources in a VLAN. What Are the Multicast Bridging Features? The PowerConnect 7000 Series switches support multicast filtering and multicast flooding. For multicast traffic, the switch uses a database called the Layer 2 Multicast Forwarding Database (MFDB) to make forwarding Configuring L2 Multicast Features 703 decisions for packets that arrive with a multicast destination MAC address. By limiting multicasts to only certain ports in the switch, traffic is prevented from going to parts of the network where that traffic is unnecessary. When a packet enters the switch, the destination MAC address is combined with the VLAN ID, and a search is performed in the Layer 2 MFDB. If no match is found, then the packet is flooded. If a match is found, then the packet is forwarded only to the ports that are members of that multicast group within the VLAN. Multicast traffic destined to well-known (reserved) multicast IP addresses (control plane traffic) is always flooded to all ports in the VLAN. The wellknown IP multicast addresses are 224.0.0.x for IPv4 and FF0x:: for IPv6. Multicast data traffic is flooded to all ports in the VLAN if no multicast router ports have been identified. Once a multicast router port is identified, multicast data traffic is forwarded to the multicast router ports. The MFDB is populated by snooping the membership reports sent to the multicast routers. This causes multicast data traffic to be forwarded to any hosts joining the multicast group. What Is L2 Multicast Traffic? L3 IP multicast traffic is traffic that is destined to a host group. Host groups are identified by class D IPv4 addresses, which range from 224.0.1.0 to 239.255.255.255, or by FF0x:: or FF3x:: IPv6 addresses. In contrast to L3 multicast traffic, L2 multicast traffic is identified by the MAC address, i.e., the range 01:00:5e:00:00:00 to 01:00:5e:7f:ff:ff:ff for IPv4 multicast traffic or 33:33:xx:xx:xx:xx for IPv6 multicast traffic. When a packet with a broadcast or multicast destination MAC address is received, the switch will flood a copy into each of the remaining network segments in accordance with the IEEE MAC Bridge standard. Eventually, the packet is made accessible to all nodes connected to the network. This approach works well for broadcast packets that are intended to be seen or processed by all connected nodes. In the case of multicast packets, however, this approach could lead to less efficient use of network bandwidth, particularly when the packet is intended for only a small number of nodes. Packets will be flooded into network segments where no node has any interest in receiving the packet. 704 Configuring L2 Multicast Features What Is IGMP Snooping? IGMP snooping allows the switch to snoop on IGMP exchanges between hosts and multicast routers. The IGMP snooping feature complies with RFC 4541. When a switch “sees” an IGMP report from a host for a given multicast address, the switch adds the host's interface/VLAN to the L2 multicast group forwarding table and floods the report to all ports in the VLAN. When the switch sees a leave message for the group, it removes the host interface/VLAN from the L2 multicast group forwarding table. IGMP snooping learns about multicast routers by listening for the following messages: • IGMP Membership queries • PIMv1 hellos • PIMv2 hellos • DVMRP probes Group addresses that fall into the range 224.0.0.x are never pruned by IGMP snooping—they are always flooded to all ports in the VLAN. Note that this flooding is based on the IP address, not the corresponding 01-00-5e-00-00-xx MAC address. When a multicast router is discovered, its interface is added to the interface distribution list for all multicast groups in the VLAN. If a switch is connected to a multicast source and no client, the switch filters the traffic from that group to all interfaces in the VLAN. If the switch sees an IGMP join from a host in the same VLAN, then it forwards the traffic to the host. Likewise, if the switch sees a multicast router in the VLAN, it forwards the group to the multicast router and does not flood in the VLAN. There is a user option to cause the switch to flood multicast sources in the VLAN if no multicast clients are present. By default, multicast routers are aged out every five minutes. The user can control whether or not multicast routers age out. If all multicast routers age out, the switch floods the VLAN with the multicast group. Multicast routers send an IGMP query every 60 seconds. This query is intercepted by the switch and forwarded to all ports in the VLAN. All hosts that are members of the group answer that query. The switch intercepts the replies and forwards only one report per group from all of the received responses. Configuring L2 Multicast Features 705 In summary: • IGMP snooping controls the flooding/forwarding behavior for multicast groups. Multicast data is flooded in the VLAN until a multicast router port is identified. • IGMP snooping is enabled by default • Multicast filtering is enabled by default • IGMP snooping forwards multicast sources to multicast routers by default • Reserved multicast IP addresses (224.0.0.x) are always flooded to all ports in the VLAN • Unregistered multicast traffic may be flooded in the VLAN by a user configuration option. NOTE: It is strongly recommended that users enable MLD snooping if IGMP snooping is enabled and vice-versa. This is because both IGMP snooping and MLD snooping utilize the same forwarding table and not enabling both may cause unwanted pruning of protocol packets utilized by other protocols, e.g. OSPFv3. IGMP Snooping Querier When PIM and IGMP are enabled in a network with IP multicast routing, the IP multicast router acts as the IGMP querier. However, if the IP-multicast traffic in a VLAN needs to be Layer 2 switched only, an IP-multicast router is not required. The IGMP snooping querier can perform the role of generating IGMP queries that would normally be performed by the multicast router. NOTE: Without an IP-multicast router on a VLAN, you must configure another switch as the IGMP querier so that it can send queries. When IGMP snooping querier is enabled, the querier switch sends out periodic IGMP queries that trigger IGMP report messages from the hosts that want to receive IP multicast traffic. The IGMP snooping feature listens to these IGMP reports to identify multicast router ports. If there is another querier in the network and the local querier is in election mode, then the querier with the lower IP address is elected and the other querier stops querying. If the local querier is not in election mode and another querier is detected, the local querier stops querying. 706 Configuring L2 Multicast Features What Is MLD Snooping? In IPv4, Layer 2 switches can use IGMP snooping to limit the flooding of multicast traffic by dynamically configuring the multicast forwarding database so that multicast data traffic is forwarded to only those ports associated with a multicast router or host that has indicated an interest in receiving a particular multicast group. In IPv6, MLD snooping performs a similar function. With MLD snooping, IPv6 multicast data is selectively forwarded to a list of ports that want to receive the data instead of being flooded to all ports in a VLAN. This list is constructed in the MFDB by snooping IPv6 multicast control packets. MLD snooping floods multicast data packets until a multicast router port has been identified. MLD snooping forwards unregistered multicast data packets to IPv6 multicast routers. MLD snooping discovers multicast routers by listening for MLD queries and populates the MFDB. MLD is a protocol used by IPv6 multicast routers to discover the presence of multicast listeners (nodes wishing to receive IPv6 multicast packets) on its directly-attached links and to discover which multicast packets are of interest to neighboring nodes. MLD is derived from IGMP; MLD version 1 (MLDv1) is equivalent to IGMPv2, and MLD version 2 (MLDv2) is equivalent to IGMPv3. MLD is a subprotocol of Internet Control Message Protocol version 6 (ICMPv6), and MLD messages are a subset of ICMPv6 messages. The switch snoops both MLDv1 and MLDv2 protocol packets and forwards IPv6 multicast data based on destination IPv6 multicast MAC addresses (33:33::). The switch floods multicast control plane traffic addressed to the permanently assigned (well-known) multicast address FF0x::/12 to all ports in the VLAN, except for MLD packets, which are handled according the MLD snooping rules. NOTE: It is strongly recommended that users enable IGMP snooping if MLD snooping is enabled and vice-versa. This is because both IGMP snooping and MLD snooping utilize the same forwarding table, and not enabling both may cause unwanted pruning of protocol packets utilized by other protocols, e.g. OSPFv2. Configuring L2 Multicast Features 707 What Is Multicast VLAN Registration? IGMP snooping helps limit multicast traffic when member ports are in the same VLAN; however, when ports belong to different VLANs, a copy of the multicast stream is sent to each VLAN that has member ports in the multicast group. MVR eliminates the need to duplicate the multicast traffic when multicast group member ports belong to different VLANs. MVR uses a dedicated multicast VLAN to forward multicast traffic over the L2 network. Only one MVLAN can be configured per switch, and it is used only for certain multicast traffic, such as traffic from an IPTV application, to avoid duplication of multicast streams for clients in different VLANs. Clients can dynamically join or leave the mutlicast VLAN without interfering with their membership in other VLANs. MVR, like IGMP snooping, allows a layer 2 switch to listen to IGMP messages to learn about multicast group membership. There are two types of MVR ports: source and receiver. • Source port is the port where multicast traffic is flowing to. It has to be the member of so called multicast VLAN. • Receiver port is the port where listening host is connected to the switch. It can be the member of any VLAN, except multicast VLAN. There are two configured learning modes of the MVR operation: dynamic and compatible. • In the dynamic mode MVR learns existent multicast groups by parsing the IGMP queries from router on source ports and forwarding the IGMP joins from the hosts to the router. • In the compatible mode MVR does not learn multicast groups, but they have to be configured by administrator and protocol does not forward joins from the hosts to the router. To work in this mode the IGMP router has to be configured to transmit required multicast streams to the network with the MVR switch. Enabling MVR and IGMP on the Same Interface MVR and IGMP snooping operate independently and can both be enabled on an interface. When both MVR and IGMP snooping are enabled, MVR listens to the IGMP join and report messages for static multicast group information, and IGMP snooping manages dynamic multicast groups. 708 Configuring L2 Multicast Features When Are L3 Multicast Features Required? In addition to L2 multicast features, the switch suports IPv4 and IPv6 multicast features. You configure the IPv4/IPv6 multicast features if the switch functions as a multicast router that can route multicast traffic between VLAN routing interfaces. In this case, you must enable a multicast routing protocol on the switch, such as PIM-SM. For information about L3 multicast features, see "Managing IPv4 and IPv6 Multicast" on page 1153. If the switch functions as a multicast router, it is possible to enable both IGMP and IGMP snooping so that IGMP forwards multicast traffic for directly connected hosts between VLANs, and IGMP snooping prevents the multicast router from flooding incoming multicast packets on the ingress VLAN. NOTE: If a multicast source is connected to a VLAN on which both L3 multicast and IGMP snooping are enabled, the multicast source is forwarded to the mrouter ports that have been discovered when the multicast source is first seen. If a new mrouter is later discovered on a different port, the multicast source data is not forwarded to the new port. Likewise, if an existing mrouter times out or stops querying, the multicast source data continues to be forwarded to that port. If a host in the VLAN subsequently joins or leaves the group, the list of mrouter ports is updated for the multicast source and the forwarding of the multicast source is adjusted. The workaround to this limitation is to statically configure mrouter ports when enabling IGMP snooping in L3 multicast enabled VLANs. NOTE: If MVR is enabled, IP Multicast should be disabled. Multicast routing and MVR cannot coexist on a switch. For information about configuring a PowerConnect 7000 Series switch as a multicast router that also performs IGMP snooping, see "Configuring Multicast VLAN Routing With IGMP and PIM-SM" on page 1237. What Are GARP and GMRP? Generic Attribute Registration Protocol (GARP) is a general-purpose protocol that registers any network connectivity or membership-style information. GARP defines a set of switches interested in a given network attribute, such as VLAN ID or multicast address. Configuring L2 Multicast Features 709 PowerConnect 7000 Series switches can use GARP functionality for two applications: • GARP VLAN Registration Protocol (GVRP) to help dynamically manage VLAN memberships on trunk ports. • GARP Multicast Registration Protocol (GMRP) to help control the flooding of multicast traffic by keeping track of group membership information. GVRP and GMRP use the same set of GARP Timers to specify the amount of time to wait before transmitting various GARP messages. GMRP is similar to IGMP snooping in its purpose, but IGMP snooping is more widely used. GMRP must be running on both the host and the switch to function properly and IGMP/MLD snooping must be disabled on the switch, as IGMP snooping and GMRP cannot simultaneously operate within the same VLAN. 710 Configuring L2 Multicast Features Snooping Switch Restrictions Partial IGMPv3 and MLDv2 Support The IGMPv3 and MLDv2 protocols allow multicast listeners to specify the list of hosts from which they want to receive the traffic. However the PowerConnect snooping switch does not track this information. IGMPv3/MLDv2 Report messages that have the group record type CHANGE_TO_INCLUDE_MODE with a null source list are treated as Leave messages. All other report messages are treated as IGMPv2/MLDv1 Report messages. MAC Address-Based Multicast Group The L2 multicast forwarding table consists of the Multicast group MAC address filtering entries. For IPv4 multicast groups, 16 IP multicast group addresses map to the same multicast MAC address. For example, 224.1.1.1 and 225.1.1.1 map to the MAC address 01:00:5E:01:01:01, and IP addresses in the range [224-239].3.3.3 map to 01:00:5E:03:03:03. As a result, if a host requests 225.1.1.1, then it might receive multicast traffic of group 226.1.1.1 as well. IGMP/MLD Snooping in a Multicast Router IGMP/MLD snooping is a Layer 2 feature and is achieved by using the L2 multicast forwarding table. If a multicast source is connected to a VLAN on which both L3 multicast and IGMP/MLD snooping are enabled, the multicast source is forwarded to the mrouter ports that have been discovered when the multicast source is first seen. If a new mrouter is later discovered on a different port, the multicast source data is not forwarded to the new port. Likewise, if an existing mrouter times out or stops querying, the multicast source data continues to be forwarded to that port. If a host in the VLAN subsequently joins or leaves the group, the list of mrouter ports is updated for the multicast source, and the forwarding of the multicast source is adjusted. The workaround to this limitation is to statically configure mrouter ports when enabling IGMP/MLD snooping in L3 multicast enabled VLANs. Configuring L2 Multicast Features 711 Topologies Where the Multicast Source Is Not Directly Connected to the Querier If the multicast source is not directly connected to a multicast querier, the multicast stream is forwarded to any router ports on the switch (within the VLAN). Because multicast router queries are flooded to all ports in the VLAN, intermediate IGMP snooping switches will receive the multicast stream from the multicast source and forward it to the multicast router. Using Static Multicast MAC Configuration If configuring static multicast MAC group addresses on a port in a VLAN, it is necessary to configure all ports in the VLAN over which it is desired that the group traffic flow (both host and router) on all switches. IGMP snooping does not dynamically add ports to a VLAN for a multicast group when a static entry is configured for that group in the VLAN. This restriction applies to both multicast router-connected ports and host-connected ports. IGMP Snooping and GMRP IGMP snooping and GMRP are not compatible. Only one of IGMP snooping or GMRP should be configured to filter multicast groups for any VLAN. Simultaneous operation of GMRP and IMGP snooping is not supported and will lead to undesirable results, such as flooding in the VLAN due to the inability to identify multicast router ports. 712 Configuring L2 Multicast Features Default L2 Multicast Values Details about the L2 multicast are in Table 25-1. Table 25-1. L2 Multicast Defaults Parameter Default Value IGMP Snooping mode Enabled MLD Snooping mode Enabled Bridge multicast group None configured IGMP/MLD snooping Enabled on all VLANs IGMP/MLD snooping auto-learn Disabled IGMP/MLD snooping host timeout 260 seconds IGMP/MLD snooping multicast router timeout 300 seconds IGMP/MLD snooping leave timeout 10 seconds IGMP snooping querier Disabled IGMP version v2 MLD version v1 IGMP/MLD snooping querier query interval 60 seconds IGMP/MLD snooping querier expiry interval 60 seconds IGMP/MLD snooping VLAN querier Disabled VLAN querier election participate mode Disabled Snooping Querier VLAN Address 0.0.0.0 MVR running Disabled MVR multicast VLAN 1 MVR max multicast groups 256 MVR Global query response time 5 tenths of a second MVR Mode Compatible GARP Leave Timer 60 centiseconds GARP Leave All Timer 1000 centiseconds GARP Join Timer 20 centiseconds Configuring L2 Multicast Features 713 Table 25-1. L2 Multicast Defaults (Continued) Parameter Default Value GMRP Disabled globally and per-interface 714 Configuring L2 Multicast Features Configuring L2 Multicast Features (Web) This section provides information about the OpenManage Switch Administrator pages for configuring and monitoring L2 multicast features on a PowerConnect 7000 Series switch. For details about the fields on a page, click at the top of the page. Multicast Global Parameters Use the Multicast Global Parameters page to enable or disable bridge multicast filtering, IGMP snooping, or MLD snooping on the switch. To display the Multicast Global Parameters page, click Switching → Multicast Support → Global Parameters in the navigation menu. Figure 25-1. Multicast Global Parameters NOTE: It is strongly recommended that users enable IGMP snooping if MLD snooping is enabled and vice-versa. This is because both IGMP snooping and MLD snooping utilize the same forwarding table, and not enabling both may cause unwanted pruning of protocol packets utilized by other protocols, e.g. OSPFv2. Configuring L2 Multicast Features 715 Bridge Multicast Group Use the Bridge Multicast Group page to create new multicast service groups or to modify ports and LAGs assigned to existing multicast service groups. Attached interfaces display in the Port and LAG tables and reflect the manner in which each is joined to the Multicast group. To display the Bridge Multicast Group page, click Switching → Multicast Support → Bridge Multicast Group in the navigation menu. Figure 25-2. Bridge Multicast Group Understanding the Port and LAG Member Tables The Bridge Multicast Group tables display which Ports and LAGs are members of the multicast group, and whether they’re static (S), dynamic (D), or forbidden (F). The tables have two rows: Static and Current. Only the Static row is accessible from this page. The Current row is updated when the Static row is changed and Apply is clicked. The Bridge Multicast Group page contains two editable tables: 716 Configuring L2 Multicast Features • Unit and Ports — Displays and assigns multicast group membership to ports. To assign membership, click in Static for a specific port. Each click toggles between S, F, and blank. See Table 25-2 for definitions. • LAGs — Displays and assigns multicast group membership to LAGs. To assign membership, click in Static for a specific LAG. Each click toggles between S, F, and blank. See Table 25-2 for definitions. Table 25-2 contains definitions for port/LAG IGMP management settings. Table 25-2. Port/LAG IGMP Management Settings Port Control Definition D Dynamic: Indicates that the port/LAG was dynamically joined to the Multicast group (displays in the Current row). S Static: Attaches the port to the Multicast group as a static member in the Static row. Displays in the Current row once Apply is clicked. F Forbidden: Indicates that the port/LAG is forbidden entry into the Multicast group in the Static row. Displays in the Current row once Apply is clicked. Blank Blank: Indicates that the port is not attached to a Multicast group. Adding and Configuring Bridge Multicast Address Groups To configure a bridge multicast group: 1 From the Bridge Multicast Group page, click Add. The Add Bridge Multicast Group page displays. Configuring L2 Multicast Features 717 Figure 25-3. Add Bridge Multicast Group 2 Select the ID of the VLAN to add to the multicast group or to modify membership for an existing group. 3 For a new group, specify the multicast group IP or MAC address associated with the selected VLAN. 4 In the Bridge Multicast Group tables, assign a setting by clicking in the Static row for a specific port/LAG. Each click toggles between S, F, and blank. (not a member). 5 Click Apply. The bridge multicast address is assigned to the multicast group, ports/LAGs are assigned to the group (with the Current rows being updated with the Static settings), and the switch is updated. 718 Configuring L2 Multicast Features Removing a Bridge Multicast Group To delete a bridge multicast group: 1 Open the Bridge Multicast Group page. 2 Select the VLAN ID associated with the bridge multicast group to be removed from the drop-down menu. The Bridge Multicast Address and the assigned ports/LAGs display. 3 Check the Remove check box. 4 Click Apply. The selected bridge multicast group is removed, and the device is updated. MRouter Status Use the MRouter Status page to display the status of dynamically learned multicast router interfaces. To access this page, click Switching → Multicast Support → MRouter Status in the navigation panel. Figure 25-4. MRouter Status Configuring L2 Multicast Features 719 General IGMP Snooping Use the General IGMP snooping page to configure IGMP snooping settings on specific ports and LAGs. To display the General IGMP snooping page, click Switching → Multicast Support → IGMP Snooping → General in the navigation menu. Figure 25-5. General IGMP Snooping Modifying IGMP Snooping Settings for Multiple Ports, LAGs, or VLANs To modify the IGMP snooping settings: 1 From the General IGMP snooping page, click Show All. The IGMP Snooping Table displays. 2 Select the Edit checkbox for each Port, LAG, or VLAN to modify. In Figure 25-6, ports 2 and 3 are to be modified. 720 Configuring L2 Multicast Features Figure 25-6. Edit IGMP Snooping Settings 3 Edit the IGMP snooping fields as needed. 4 Click Apply. The IGMP snooping settings are modified, and the device is updated. Copying IGMP Snooping Settings to Multiple Ports, LAGs, or VLANs To copy IGMP snooping settings: 1 From the General IGMP snooping page, click Show All. The IGMP Snooping Table displays. 2 Select the Copy Parameters From checkbox. 3 Select a Unit/Port, LAG, or VLAN to use as the source of the desired parameters. 4 Select the Copy To checkbox for the Unit/Ports, LAGs, or VLANs that these parameters will be copied to. In Figure 25-7, the settings for port 3 will be copied to ports 4 and 5 and LAGs 1 and 2. Configuring L2 Multicast Features 721 Figure 25-7. Copy IGMP Snooping Settings 5 Click Apply. The IGMP snooping settings are modified, and the device is updated. 722 Configuring L2 Multicast Features Global Querier Configuration Use the Global Querier Configuration page to configure IGMP snooping querier settings, such as the IP address to use as the source in periodic IGMP queries when no source address has been configured on the VLAN. To display the Global Querier Configuration page, click Switching → Multicast Support → IGMP Snooping → Global Querier Configuration in the navigation menu. Figure 25-8. Global Querier Configuration Configuring L2 Multicast Features 723 VLAN Querier Use the VLAN Querier page to specify the IGMP snooping querier settings for individual VLANs. To display the VLAN Querier page, click Switching → Multicast Support → IGMP Snooping → VLAN Querier in the navigation menu. Figure 25-9. VLAN Querier Adding a New VLAN and Configuring its VLAN Querier Settings To configure a VLAN querier: 1 From the VLAN Querier page, click Add. The page refreshes, and the Add VLAN page displays. 724 Configuring L2 Multicast Features Figure 25-10. Add VLAN Querier 2 Enter the VLAN ID and, if desired, an optional VLAN name. 3 Return to the VLAN Querier page and select the new VLAN from the VLAN ID menu. 4 Specify the VLAN querier settings. 5 Click Apply. The VLAN Querier settings are modified, and the device is updated. Configuring L2 Multicast Features 725 To view a summary of the IGMP snooping VLAN querier settings for all VLANs on the switch, click Show All. Figure 25-11. 726 Add VLAN Querier Configuring L2 Multicast Features VLAN Querier Status Use the VLAN Querier Status page to view the IGMP snooping querier settings for individual VLANs. To display the VLAN Querier Status page, click Switching → Multicast Support → IGMP Snooping → VLAN Querier Status in the navigation menu. Figure 25-12. IGMP Snooping VLAN Querier Status Configuring L2 Multicast Features 727 MFDB IGMP Snooping Table Use the MFDB IGMP Snooping Table page to view the multicast forwarding database (MFDB) IGMP Snooping Table and Forbidden Ports settings for individual VLANs. To display the MFDB IGMP Snooping Table page, click Switching → Multicast Support → IGMP Snooping → MFDB IGMP Snooping Table in the navigation menu. Figure 25-13. 728 MFDB IGMP Snooping Table Configuring L2 Multicast Features MLD Snooping General Use the MLD Snooping General page to add MLD members. To access this page, click Switching → Multicast Support → MLD Snooping → General in the navigation panel. Figure 25-14. MLD Snooping General Modifying MLD Snooping Settings for VLANs To configure MLD snooping: 1 From the General MLD snooping page, click Show All. The MLD Snooping Table displays. Configuring L2 Multicast Features 729 Figure 25-15. MLD Snooping Table 2 Select the Edit checkbox for each VLAN to modify. 3 Edit the MLD snooping fields as needed. 4 Click Apply. The MLD snooping settings are modified, and the device is updated. 730 Configuring L2 Multicast Features Copying MLD Snooping Settings to VLANs To copy MLD snooping settings: 1 From the General MLD snooping page, click Show All. The MLD Snooping Table displays. 2 Select the Copy Parameters From checkbox. 3 Select a VLAN to use as the source of the desired parameters. 4 Select the Copy To checkbox for the VLANs that these parameters will be copied to. 5 Click Apply. The MLD snooping settings are modified, and the device is updated. MLD Snooping Global Querier Configuration Use the MLD Snooping Global Querier Configuration page to configure the parameters for the MLD snooping querier. To display the Global Querier Configuration page, click Switching → Multicast Support → MLD Snooping → Global Querier Configuration in the navigation menu. Figure 25-16. MLD Snooping Global Querier Configuration Configuring L2 Multicast Features 731 MLD Snooping VLAN Querier Use the MLD Snooping VLAN Querier page to specify the MLD snooping querier settings for individual VLANs. To display the MLD Snooping VLAN Querier page, click Switching → Multicast Support → MLD Snooping → VLAN Querier in the navigation menu. Figure 25-17. MLD Snooping VLAN Querier Adding a New VLAN and Configuring its MLD Snooping VLAN Querier Settings To configure an MLD snooping VLAN querier: 1 From the VLAN Querier page, click Add. The page refreshes, and the Add VLAN page displays. 732 Configuring L2 Multicast Features Figure 25-18. Add MLD Snooping VLAN Querier 2 Enter the VLAN ID and, if desired, an optional VLAN name. 3 Return to the VLAN Querier page and select the new VLAN from the VLAN ID menu. 4 Specify the VLAN querier settings. 5 Click Apply. The VLAN Querier settings are modified, and the device is updated. To view a summary of the IGMP snooping VLAN querier settings for all VLANs on the switch, click Show All. Figure 25-19. Add VLAN Querier Configuring L2 Multicast Features 733 MLD Snooping VLAN Querier Status Use the VLAN Querier Status page to view the MLD snooping querier settings for individual VLANs. To display the VLAN Querier Status page, click Switching → Multicast Support → MLD Snooping → VLAN Querier Status in the navigation menu. Figure 25-20. 734 MLD Snooping VLAN Querier Status Configuring L2 Multicast Features MFDB MLD Snooping Table Use the MFDB MLD Snooping Table page to view the MFDB MLD snooping table settings for individual VLANs. To display the MFDB MLD Snooping Table page, click Switching → Multicast Support → MLD Snooping → MFDB MLD Snooping Table in the navigation menu. Figure 25-21. MFDB MLD Snooping Table Configuring L2 Multicast Features 735 MVR Global Configuration Use the MVR Global Configuration page to enable the MVR feature and configure global parameters. To display the MVR Global Configuration page, click Switching → MVR Configuration → Global Configuration in the navigation panel. Figure 25-22. 736 MVR Global Configuration Configuring L2 Multicast Features MVR Members Use the MVR Members page to view and configure MVR group members. To display the MVR Members page, click Switching → MVR Configuration → MVR Members in the navigation panel. Figure 25-23. MVR Members Adding an MVR Membership Group To add an MVR membership group: 1 From the MVR Membership page, click Add. The MVR Add Group page displays. Configuring L2 Multicast Features 737 Figure 25-24. MVR Member Group 2 Specify the MVR group IP multicast address. 3 Click Apply. MVR Interface Configuration Use the MVR Interface Configuration page to enable MVR on a port, configure its MVR settings, and add the port to an MVR group. To display the MVR Interface Configuration page, click Switching → MVR Configuration → MVR Interface Configuration in the navigation panel. Figure 25-25. 738 MVR Interface Configuration Configuring L2 Multicast Features To view a summary of the MVR interface configuration, click Show All. Figure 25-26. MVR Interface Summary Adding an Interface to an MVR Group To add an interface to an MVR group: 1 From the MVR Interface page, click Add. Figure 25-27. MVR - Add to Group 2 Select the interface to add to the MVR group. 3 Specify the MVR group IP multicast address. 4 Click Apply. Configuring L2 Multicast Features 739 Removing an Interface from an MVR Group To remove an interface from an MVR group: 1 From the MVR Interface page, click Remove. Figure 25-28. MVR - Remove from Group 2 Select the interface to remove from an MVR group. 3 Specify the IP multicast address of the MVR group. 4 Click Apply. 740 Configuring L2 Multicast Features MVR Statistics Use the MVR Statistics page to view MVR statistics on the switch. To display the MVR Statistics page, click Switching → MVR Configuration → MVR Statistics in the navigation panel. Figure 25-29. MVR Statistics Configuring L2 Multicast Features 741 GARP Timers The Timers page contains fields for setting the GARP timers used by GVRP and GMRP on the switch. To display the Timers page, click Switching → GARP → Timers in the navigation panel. Figure 25-30. GARP Timers Configuring GARP Timer Settings for Multiple Ports To configure GARP timers on multiple ports: 1 Open the Timers page. 2 Click Show All to display the GARP Timers Table. 742 Configuring L2 Multicast Features Figure 25-31. Configure STP Port Settings 3 For each port or LAG to configure, select the check box in the Edit column in the row associated with the port. 4 Specify the desired timer values. 5 Click Apply. Configuring L2 Multicast Features 743 Copying GARP Timer Settings From One Port to Others To copy GARP timer settings: 1 Select the Copy Parameters From check box, and select the port or LAG with the settings to apply to other ports or LAGs. 2 In the Ports or LAGs list, select the check box(es) in the Copy To column that will have the same settings as the port selected in the Copy Parameters From field. 3 Click Apply to copy the settings. GMRP Parameters Use the GMRP Parameters page to configure the administrative mode of GMRP on the switch and on each port or LAG. To display the GMRP Parameters page, click Switching → GARP → GMRP Parameters in the navigation panel. Figure 25-32. GMRP Parameters Configuring GMRP Parameters on Multiple Ports To configure GMRP settings: 1 Open the GMRP Parameters page. 2 Click Show All to display the GMRP Port Configuration Table. 744 Configuring L2 Multicast Features Figure 25-33. GMRP Port Configuration Table 3 For each port or LAG to configure, select the check box in the Edit column in the row associated with the port. 4 Specify the desired timer values. 5 Click Apply. Configuring L2 Multicast Features 745 Copying Settings From One Port or LAG to Others To copy GMRP settings: 1 Select the Copy Parameters From check box, and select the port or LAG with the settings to apply to other ports or LAGs. 2 In the Ports or LAGs list, select the check box(es) in the Copy To column that will have the same settings as the port selected in the Copy Parameters From field. 3 Click Apply to copy the settings. MFDB GMRP Table Use the MFDB GMRP Table page to view all of the entries in the Multicast Forwarding Database that were created for the GMRP To display the MFDB GMRP Table page, click Switching → GARP → MFDB GMRP Table in the navigation panel. Figure 25-34. 746 MFDB GMRP Table Configuring L2 Multicast Features Configuring L2 Multicast Features (CLI) This section provides information about the commands you use to configure L2 multicast settings on the switch. For more information about the commands, see the PowerConnect 7000 Series CLI Reference Guide at support.dell.com/manuals. Because L3 IP multicast (PIM/IGMP) utilizes a separate forwarding database from L2 multicast, it is recommended that L3 multicast features, including PIM and IGMP, be disabled on L2 multicast enabled switches. Configuring Layer 2 Multicasting Beginning in Privileged EXEC mode, use the following commands to configure MAC address table features. Command Purpose configure Enter global configuration mode. mac address-table static Register a MAC-layer Multicast address in the bridge mac-multicast-address table. vlan vlan-id interface • mac-multicast-address — MAC multicast address in the interface-id format xxxx.xxxx.xxxx or xx:xx:xx:xx:xx:xx. • interface-id — A physical interface or port-channel. mac address-table multicast forbidden address vlan vlan-id {mac-multicast-address | ip-multicast-address} {add | remove} interface interface-list Forbid adding a specific Multicast address to specific ports. • mac-multicast-address — MAC multicast address in the format xxxx.xxxx.xxxx. • ip- multicast-address — IP multicast address. • add — Adds ports to the group. If no option is specified, this is the default option. • remove — Removes ports from the group. • interface-list — Specifies the interface type (portchannel, gigabitethernet, tengigabitethernet) and number. Separate nonconsecutive interfaces with a comma and no spaces; use a hyphen to designate a range of ports. exit Exit to Privileged EXEC mode. Configuring L2 Multicast Features 747 Command Purpose show mac address-table multicast [vlan vlan-id] [address mac-multicastaddress | ip-multicastaddress] [format ip | mac]] View entries in the multicast MAC address table. The show mac address-table multicast command shows only multicast addresses. Multicast address are shown along with unicast addresses if the multicast keyword is not used. Configuring IGMP Snooping on VLANs Beginning in Privileged EXEC mode, use the following commands to configure IGMP snooping settings on VLANs. Command Purpose configure Enter global configuration mode. ip igmp snooping vlan Enable IGMP snooping on the specified VLAN. ip igmp snooping vlan Specify the host time-out value for the specified VLAN. If an IGMP report for a multicast group is not received in the number of seconds specified by the seconds value, this port is deleted from the VLAN member list of that multicast group. This command also enables IGMP snooping on the VLAN. vlan-id vlan-id groupmembershipinterval seconds ip igmp snooping vlan Specify the leave time-out value for the VLAN. If an IGMP report for a multicast group is not received within the number of seconds configured with this command after an IGMP leave was received from a specific interface, the current port is deleted from the VLAN member list of that multicast group. ip igmp snooping vlan Enables IGMP snooping immediate-leave mode on the vlan-id last-memberquery-interval seconds vlan-id immediate-leave specified VLAN. Enabling immediate-leave allows the switch to immediately remove the layer 2 LAN interface from its forwarding table entry upon receiving an IGMP leave message for that multicast group without first sending out MAC-based general queries to the interface. 748 Configuring L2 Multicast Features Command Purpose ip igmp snooping vlan vlan-id mcrtexpiretime Specify the multicast router time-out value for to associate with a VLAN. This command sets the number of seconds to wait to age out an automatically-learned multicast router port. CTRL + Z Exit to Privileged EXEC mode. show ip igmp snooping groups Shows IGMP snooping configuration on all VLANs. show ip igmp snooping vlan vlan-id View the IGMP snooping settings on the VLAN. seconds Configuring IGMP Snooping Querier Beginning in Privileged EXEC mode, use the following commands to configure IGMP snooping querier settings on the switch and on VLANs. Command Purpose configure Enter global configuration mode. ip igmp snooping querier Enable the IGMP snooping querier on the switch or on [vlan vlan-id] [address the VLAN specified with the vlan-id parameter. ip-address] Use the optional ip-address parameter to specify the IP address that the snooping querier switch should use as the source address when generating periodic queries. ip igmp snooping querier Set the IGMP snooping querier query interval time, which query-interval interval- is the amount of time in seconds that the switch waits count before sending another periodic query. The range is 1–1800 seconds. ip igmp snooping querier Set the IGMP snooping querier timer expiration period. This is the time period, in seconds, that the switch timer expiry seconds remains in non-querier mode after it has discovered that there is a multicast querier in the network. ip igmp snooping querier Set the IGMP version of the query that the switch sends version version periodically. The version range is 1–2. ip igmp snooping querier Enable the IGMP snooping querier on the specified VLAN. vlan-id Configuring L2 Multicast Features 749 Command Purpose ip igmp snooping querier Allow the IGMP snooping querier to participate in the election participate vlan- querier election process when it discovers the presence of id another querier in the VLAN. When this mode is enabled, if the snooping querier finds that the other querier source address is more than the snooping querier address, it stops sending periodic queries. If the snooping querier wins the election, then it continues sending periodic queries and the other querier ceases sending queries. Use of election mode is not recommended when multicast routers are present in the network. CTRL + Z Exit to Privileged EXEC mode. show ip igmp snooping querier [detail |vlan vlan-id] View IGMP snooping querier settings configured on the switch, on all VLANs, or on the specified VLAN. Configuring MLD Snooping on VLANs Beginning in Privileged EXEC mode, use the following commands to configure MLD snooping settings on VLANs. Command Purpose configure Enter global configuration mode. ipv6 mld snooping vlan Enable MLD snooping on the specified VLAN. ipv6 mld snooping vlan Specify the host time-out value for the specified VLAN. If an MLD report for a multicast group is not received in the number of seconds specified by the seconds value, this VLAN is deleted from the member list of that multicast group. vlan-id vlan-id groupmembershipinterval seconds ipv6 mld snooping vlan- Specify the leave time-out value for the VLAN. If an MLD id last-listener-queryreport for a multicast group is not received within the number of seconds configured with this command after interval seconds an MLD leave was received from a specific interface, the current port is deleted from the VLAN member list of that multicast group. 750 Configuring L2 Multicast Features Command Purpose ipv6 mld snooping vlan Enables MLD snooping immediate-leave mode on the vlan-id immediate-leave specified VLAN. Enabling immediate-leave allows the switch to immediately remove the layer 2 LAN interface from its forwarding table entry upon receiving an MLD leave message for that multicast group without first sending out MAC-based general queries to the interface. vlan-id mcrtexpiretime seconds ipv6 mld snooping vlan Specify the multicast router time-out value for to associate with a VLAN. This command sets the number of seconds to wait to age out an automatically-learned multicast router port. CTRL + Z Exit to Privileged EXEC mode. show ipv6 mld snooping View the MLD snooping settings on the VLAN. vlan vlan-id Configuring MLD Snooping Querier Beginning in Privileged EXEC mode, use the following commands to configure MLD snooping querier settings on the switch and on VLANs. Command Purpose configure Enter global configuration mode. ipv6 mld snooping querier Enable the MLD snooping querier on the switch. ipv6 mld snooping querier vlan vlan-id [address ipv6-address] Enable the MLD snooping querier on VLAN specified with the vlan-id parameter. Use the optional ip-address parameter to specify the IP address that the snooping querier switch should use as the source address when generating periodic queries. Configuring L2 Multicast Features 751 Command Purpose ipv6 mld snooping querier election participate vlan-id Allow the MLD snooping querier to participate in the querier election process when it discovers the presence of another querier in the VLAN. When this mode is enabled, if the snooping querier finds that the other querier source address is more than the snooping querier address, it stops sending periodic queries. If the snooping querier wins the election, then it continues sending periodic queries. Use of election mode is not recommended when multicast routers are present in the network. exit Exit to Global Configuration mode. ipv6 mld snooping querier address ipv6- Specify the IP address that the snooping querier switch should use as the source address when generating periodic queries. ipv6 mld snooping querier query-interval Set the MLD snooping querier query interval time, which is the amount of time in seconds that the switch waits before sending another periodic query. The range is 1–1800 seconds. ipv6 mld snooping querier timer expiry Set the MLD snooping querier timer expiration period. This is the time period, in seconds, that the switch remains in non-querier mode after it has discovered that there is a multicast querier in the network. exit Exit to Privileged EXEC mode. address interval-count seconds show ipv6 mld snooping View MLD snooping querier settings configured on the switch, on all VLANs, or on the specified VLAN. querier [detail |vlan vlan-id] Configuring MVR Beginning in Privileged EXEC mode, use the following commands to configure MVR features on the switch. Command Purpose configure Enter global configuration mode. mvr Enable MVR on the switch. mvr vlan vlan-id Set the VLAN to use as the multicast VLAN for MVR. 752 Configuring L2 Multicast Features Command Purpose mvr querytime time Set the MVR query response time. The value for time is in units of tenths of a second. mvr mode {compatible | Specify the MVR mode of operation. dynamic} mvr group mcast-address Add an MVR membership group. [groups] • mcast-address—The group IP multicast address • group—Specifies the number of contiguous groups interface interface Enter interface configuration mode for the specified port. The interface variable includes the interface type and number, for example gigabitethernet 1/0/3. You can also specify a range of ports with the interface range command, for example, interface range gigabitethernet 1/0/8-12 configures interfaces 8, 9, 10, 11, and 12. mvr Enable MVR on the port. mvr immediate Enable MVR immediate leave mode on the port. mvr type {source | receiver} Specify the MVR port type. mvr vlan vlan-id group mcast-address Allow the port to participate in the specified MVR group. The vlan-id parameter is the ID of the MVR multicast VLAN. CTRL + Z Exit to Privileged EXEC mode. show ip dhcp snooping [interfaces] View the DHCP snooping global and per port configuration. show ip dhcp snooping binding [{static | dynamic}] [interface port] [vlan vlan-id] View the entries in the DHCP snooping bindings database. show mvr View information about the administrative mode of MVR. show mvr members View information about MVR groups and their members. interface show mvr interface View information about the MVR configuration for a specific port. show mvr traffic View information about IGMP traffic in the MVR table. Configuring L2 Multicast Features 753 Configuring GARP Timers and GMRP Beginning in Privileged EXEC mode, use the following commands to configure the GARP timers and to control the administrative mode GMRP on the switch and per-interface. Command Purpose configure Enter global configuration mode. garp timer {join | leave | Adjust the GARP application join, leave, and leaveall GARP timer values leaveall} timer_value The timer_value variable is in centiseconds. The range is 10-100 for join, 20-600 for leave, and 200-6000 for leaveall. gmrp enable Enable GMRP globally on the switch. interface interface Enter interface configuration mode for the specified port or LAG. The interface variable includes the interface type and number, for example gigabitethernet 1/0/3. For a LAG, the interface type is port-channel. You can also specify a range of ports with the interface range command, for example, interface range gigabitethernet 1/0/8-12 configures interfaces 8, 9, 10, 11, and 12. gmrp enable Enable GMRP on the interface or range of interfaces. exit Exit to Global Config mode. exit Exit to Privileged EXEC mode. show gmrp configuration View the administrative status of GMRP on the switch and all interfaces. 754 Configuring L2 Multicast Features Case Study on a Real-World Network Topology Multicast Snooping Case Study Figure 25-35 shows the topology that the scenarios in this case study use. Figure 25-35. Case Study Topology The topology in Figure 25-35 includes the following elements: • Snooping Switches: D1, D2, D3 with IGMP snooping enabled on VLANs 10, 20 • Multicast Router: D4 with PIM-SM enabled and IGMP snooping disabled on VLANs 10, 20 • Multicast Listeners: Client A-G Configuring L2 Multicast Features 755 • Multicast Sources: Server A – 239.20.30.40, Server B – 239.20.30.42 • Subnets: VLAN 10 – 192.168.10.x, VLAN 20 – 192.168.20.x • Mrouter ports: D3 – 1/0/20, D2 – PortChannel1, D1 – 1/0/15 Snooping Within a Subnet In the example network topology, the multicast source and listeners are in the same subnet VLAN 20 – 192.168.20.x/24. D4 sends periodic queries on VLAN 10 and 20, and these queries are forwarded to D1, D2, and D3 via trunk links. Snooping switches D1, D2, and D3 flood these queries in VLANs 10 and 20 to clients G, F, and D, respectively. Multicast Source and Listener directly connected to a snooping switch: Server B  Client G 1 Client G sends a report for 239.20.30.42. 2 The report is forwarded to multicast router D4 via D1 – 1/0/15 and D3 – 1/0/20. 3 A forwarding entry is created by D1 for VLAN 20, 239.20.30.42 – 1/0/8, 1/0/15. 4 Client G receives the multicast stream from Server B. 5 D3 receives the multicast stream and it is forwarded to D4 because D4 is a multicast router. 6 Client D sends a report for 239.20.30.42. 7 The report is forwarded to multicast router D4 via D3 – 1/0/20. 8 A forwarding entry is created by D3 for VLAN 20, 239.20.30.42 – 1/0/6, 1/0/20. 9 Client D receives the multicast stream from Server B. 10 Client F does not receive the multicast stream because it did not respond to queries from D4. Multicast Source and Listener connected by intermediate snooping switches: Server B  Client D 1 Client D sends a report for 239.20.30.42. 2 The report is forwarded to multicast router D4 via D3 – 1/0/20. 756 Configuring L2 Multicast Features 3 A forwarding entry is created by D3 for VLAN20, 239.20.30.42 – 1/0/6, 1/0/20. 4 Client D will receive the multicast stream from Server B because it is forwarded by D1 to D3 and then to D4 because D4 is a multicast router. Because the multicast stream is present on D3, a L2 forwarding entry is created on D3, where 239.20.30.42 is not a registered group. 5 Client F does not receive the multicast stream because it did not respond to queries from D4. Snooping Switch Interaction with a Multicast Router In the example network topology, consider Client B and Server A. Both are in the same subnet VLAN10 – 192.168.10.70/24. Server A is a source for multicast stream 239.20.30.40. D4 sends periodic queries on VLAN 10 and VLAN 20, and these queries reach D1, D2, and D3 via trunk links, which in turn forward them in VLAN 10 and VLAN 20 to reach their respective attached clients. PIM-SM is enabled and IGMP snooping is disabled on router D4, and IGMP snooping is enabled on D1, D2, and D3. Multicast Source and Listener directly connected to Multicast Router on the same routing VLAN: Server A  Client B 1 Because multicast routing is enabled on D4 VLAN 10, an IP multicast table entry is created to include D4 – 1/0/15, D4 – 1/0/20 as part of the L2 forwarding list members. 2 Client B sends a report for 239.20.30.40. 3 The IP multicast table entry is modified to include only D4 – 1/0/15 as the layer 2 forwarding list member. 4 Client B receives multicast data. 5 The multicast stream is not forwarded to D3 on trunk link 1/0/20 because no other clients requested this data. Multicast Source directly connected to Multicast Router, and Listener connected to a different routing VLAN via intermediate snooping switches: Server A  Client F Clients A, D and F are in the same subnet VLAN20 - 192.168.20.70/24. Server A is in a different subnet VLAN10 – 192.168.10.70/24. 1 Client F sends a report for 239.20.30.40. Configuring L2 Multicast Features 757 2 A multicast forwarding entry is created on D2 VLAN20, 239.20.30.40 – 1/0/20, PortChannel1. 3 The Client F report message is forwarded to D3-PortChannel1 (multicast router attached port). 4 A multicast forwarding entry is created on D3 VLAN 20, 239.20.30.40 – PortChannel1, 1/0/20. 5 The Client F report message is forwarded to D4 via D3 – 1/0/20 (multicast router attached port). 6 An IP multicast routing entry is created on D4 VLAN 10 – VLAN 20 with the L3 outgoing port list as VLAN 20 – 1/0/20. 7 The multicast stream is routed to D3. 8 The multicast stream is forwarded to listener Client F using forwarding entries created on D3 and D2. 9 Clients A and D do not receive the Server A multicast stream because they did not send a report. Multicast Source connected to Multicast Router via intermediate snooping switches, and Listener directly connected to multicast router in a different routing interface: Server B  Client B Server A and Clients B, C, and E are on the same subnet VLAN10 – 192.168.10.70/24. Server B is in a different subnet VLAN20 – 192.168.20.70/24. 1 Client B sends a report for 239.20.30.42. 2 Multicast Router D4 learns group 239.20.30.42. 3 The administrator creates a static multicast forwarding entry on D1 VLAN 20, 239.20.30.42 – 1/0/15 and on D3 VLAN 20, 239.20.30.42 – 1/0/20. 4 The multicast stream from Server B reaches D4 via trunk links because it is a statically registered group on D1 and D3. D4 is a multicast router. 5 An IP multicast routing entry is created on D4 VLAN 20 – VLAN 10 with the L3 outgoing port list as VLAN 10 – 1/0/15. 6 Client B receives multicast data from Server B. 7 Server A and Clients C and E do not receive Server B data because no report messages were sent requesting Server B traffic. 758 Configuring L2 Multicast Features Multicast Source and Listener connected to Multicast Router via intermediate snooping switches and are part of different routing VLANs: Server B  Client E Clients E, B, and C are on the same subnet VLAN10 – 192.168.10.70/24. Server B is in a different subnet VLAN20 – 192.168.20.70/24. 1 Client E sends a report for 239.20.30.42. 2 A multicast forwarding entry is created on D2 VLAN10, 239.20.30.42 – 1/0/2, PortChannel 1. 3 The report from Client E is forwarded to D3 via D2 – PortChannel 1. 4 A multicast forwarding entry is created on D3 VLAN10, 239.20.30.42 – PortChannel 1, 1/0/20. 5 The report from Client E is forwarded to D4 via D3 – 1/0/20. 6 Multicast Router D4 learns group 239.20.30.42. 7 The multicast stream from Server B reaches D4 via trunk links because it is a multicast router. 8 An IP multicast routing entry is created on D4 VLAN 20 – VLAN 10 with the L3 outgoing port list as VLAN 10 – 1/0/20. 9 Client E receives multicast data from Server B. 10 Clients B and C do not receive Server B data because no report messages were sent requesting Server B traffic. Configuring L2 Multicast Features 759 760 Configuring L2 Multicast Features 26 Configuring Connectivity Fault Management This chapter describes how to configure the Connectivity Fault Management feature, which is specified in IEEE 802.1ag (IEEE Standard for Local and Metropolitan Area Networks Virtual Bridged Local Area Networks Amendment 5: Connectivity Fault Management). This protocol, also known as Dot1ag, enables the detection and isolation of connectivity faults at the service level for traffic that is bridged over a metropolitan Ethernet LAN. The topics covered in this chapter include: • Dot1ag Overview • Default Dot1ag Values • Configuring Dot1ag (Web) • Configuring Dot1ag (CLI) • Dot1ag Configuration Example Dot1ag Overview With the emergence of Ethernet as a Metropolitan and Wide-Area Networking technology, different operators often work together to provide end-to-end services to enterprise customers. This has driven the need of a new set of OAM (Operations, Administration, and Maintenance) Protocols. Service-Level Connectivity Fault Management (CFM) is the OAM protocol provision for end-to-end service-layer instances in carrier networks. CFM provides mechanisms to support the administrator in performing connectivity checks, fault detection, fault verification and isolation, and fault notification per service in the network domain of interest. Unlike Ethernet OAM (IEEE 802.3ah), where the faults are detected and notified on a single point-to-point IEEE Std. 802.3 LAN, Dot1ag addresses fault diagnosis at the service layer across networks comprising multiple LANs, including LANs other than 802.3 media. Configuring Connectivity Fault Management 761 How Does Dot1ag Work Across a Carrier Network? A typical metropolitan area network comprises operator, service provider, and customer networks. To suit this business model, CFM relies on a functional model of hierarchical maintenance domains (MDs). These domains are assigned a unique MD level. There is a maximum of 8 levels, which can be nested but cannot overlap. Each organization can have its own maintenance domain. The MD level limits administrator access to the appropriate domain. Figure 26-1 depicts three domains: the customer subscribes to the services of a provider, who, in turn, subscribes to the services of two operators. This scenario is a likely one, since no operator has complete coverage of a large region. A service instance would span the provider network covering one or more operators. Every domain has its own network management system. Dot1ag defines OAM services that operate across these domains (the vertical arrow) and within them (the horizontal arrow) Figure 26-1. Organization of Domains Access Links, 802.3ah Customer Site 1 Customer Site 2 Customer Provider Operator 1 802.1ag Operator 3 Operator 2 Entities at different levels have different responsibilities. For example, the lower level (operator) overlooks a subset of the network in detail and provides information about its status to its higher levels such as the provider level). Higher levels have a broader, but less detailed, view of the network. As a result, a provider could include multiple operators, provided that the domains 762 Configuring Connectivity Fault Management never intersect. The operator transparently passes frames from the customer and provider, and the customer does not see the operator frames. Multiple levels within a domain (say, operator) are supported for flexibility. What Entities Make Up a Maintenance Domain? Dot1ag defines three primary entities that make up the maintenance domain: Maintenance End Points (MEPs), Maintenance Intermediate Points (MIPs), and Maintenance Associations (MAs). MEPs, and MIPs MEPs and MIPs are software or sometimes hardware per-service entities where CFM functionalities are present. • MEPs define the boundary of a maintenance domain. They initiate and respond to CFM messages. MEPs prevent the leaking of CFM messages between domains (for example, among operators or between operators and customers). Each MEP has a configurable unique identifier (MEPID) in a maintenance domain. MEPs periodically issue Continuity Check Messages (CCM) to discover each other and issue SNMP traps to report connectivity losses or malformed or incorrect CCMs. A MEP can be defined as “down MEP” or an “up MEP”. A down MEPs reside in a bridge that transmits CFM PDUs towards, and receives them from, the direction of the LAN. An up MEP resides in a bridge that transmits CFM PDUs towards, and receives them from, the direction of the Bridge Relay Entity. NOTE: An entity at the boundary of maintenance domain that offers connectivity and other services to systems outside the domain is referred to as a Domain Service Access Point (DoSAP). A MEP is a type of DoSAP whose services relate to connectivity fault management. • MIPs are entities within a domain that enable the outer domain to achieve end-to-end connectivity checks. MIPs passively receive CFM messages and respond back to the originating MEP. Figure 26-2 depicts two MEPs and the MIPs that connect them in a maintenance domain. Configuring Connectivity Fault Management 763 Figure 26-2. Maintenance Endpoints and Intermediate Points Maintenance Associations An MA is a logical connection between one or more MEPs that enables monitoring a particular service instance. Each MA is associated with a unique SVLAN ID. An MA is identified by a maintenance association ID. All MEPs in the MA are assigned the maintenance identifier (MAID) for the association. An MD consists of one or more MAs at the same domain level. Figure 26-3 depicts one provider-level domain and two operator-level domains. Dot1ag operation for a service instance is indicated by the path that traverses the different domains to provide the end-to-end connectivity fault management for the service. 764 Configuring Connectivity Fault Management Figure 26-3. Provider View for Service Level OAM What is the Administrator’s Role? On the switch, the administrator configures the customer-level maintenance domains, associations, and endpoints used to participate in Dot1ag services with other switches connected through the provider network. The Administrator can also use utilities to troubleshoot connectivity faults when reported via SNMP traps. All the domains within the customer domain should use different domain levels. Configuration Tasks The administrator defines the maintenance domains by configuring the domain level (from 0–7) and a name. For each domain, the administrator defines maintenance associations that are specified by a SVLAN ID and an MA name. Then the administrator defines the switch ports that serve as MEPs for a service instance and as MIPs within a domain. Configuring Connectivity Fault Management 765 Troubleshooting Tasks In the event of a connectivity loss between MEPs, the administrator can perform path discovery, similar to traceroute, from one MEP to any MEP or MIP in a maintenance domain using Link Trace Messages (LTMs). The connectivity loss is narrowed down using path discovery and is verified using Loop-back Messages (LBMs), which are similar to ping operations in IP networks. Default Dot1ag Values Dot1ag service are disabled by default and no maintenance domains, associations, or endpoints are configured by default. Table 26-1 shows the global default values for Dot1ag. Table 26-1. Dot1ag Global Defaults Parameter Default Value CFM Admin Mode Disabled Archive Hold Time 600 seconds When you configure an association between a VLAN and a maintenance domain, the following default value applies: Table 26-2. MA Configuration Defaults Parameter Default Value Continuity Check Message (CCM) Interval 1 second When you associate endpoints with SVLAN IDs, the following default values apply and are configurable: Table 26-3. MEP Configuration Defaults Parameter Default Value MEP Active False Continuity Check Interval (CCI) Enabled True 766 Configuring Connectivity Fault Management Configuring Dot1ag (Web) This section provides information about the OpenManage Switch Administrator pages for configuring and monitoring Dot1ag features on a PowerConnect 7000 Series switch. For details about the fields on a page, click at the top of the page. Dot1ag Global Configuration Use the Global Configuration page to enable and disable the Dot1ag admin mode and to configure the time after which inactive RMEP messages are removed from the MEP database. To display the page, click Switching → Dot1ag → Global Configuration in the tree view. Figure 26-4. Dot1ag Global Configuration Dot1ag MD Configuration Use the MD Configuration page to configure maintenance domain levels and names. To display the page, click Switching → Dot1ag → MD Configuration in the tree view. Configuring Connectivity Fault Management 767 Figure 26-5. Dot1ag MD Configuration Dot1ag MA Configuration Use the MA Configuration page to associate a maintenance domain level with one or more VLAN ID, provide a name for each maintenance association (MA), and to set the interval between continuity check messages sent by MEPs for the MA. To display the page, click Switching → Dot1ag → MA Configuration in the tree view. Figure 26-6. Dot1ag MA Configuration 768 Configuring Connectivity Fault Management To add an MA, click the Add link at the top of the page. Dot1ag MEP Configuration Use the MEP Configuration page to define switch ports as Management End Points. MEPs are configured per domain and per VLAN. To display the page, click Switching → Dot1ag → MEP Configuration in the tree view. Figure 26-7. Dot1ag MEP Configuration Configuring Connectivity Fault Management 769 To add a MEP, click the Add link at the top of the page. A VLAN must be associated with the selected domain before you configure a MEP to be used within an MA (see the MA Configuration page). Dot1ag MIP Configuration Use the MIP Configuration page to define a switch port as an intermediate bridge for a selected domain. To display the page, click Switching → Dot1ag → MIP Configuration in the tree view. Figure 26-8. Dot1ag MIP Configuration 770 Configuring Connectivity Fault Management Dot1ag RMEP Summary Use the RMEP Summary page to view information on remote MEPs that the switch has learned through CFM PDU exchanges with MEPs on the switch. To display the page, click Switching → Dot1ag → RMEP Summary in the tree view. Figure 26-9. Dot1ag RMEP Summary Configuring Connectivity Fault Management 771 Dot1ag L2 Ping Use the L2 Ping page to generate a loopback message from a specified MEP. The MEP can be identified by the MEP ID or by its MAC address. To display the page, click Switching → Dot1ag → L2 Ping in the tree view. Figure 26-10. Dot1ag L2 Ping Dot1ag L2 Traceroute Use the L2 Traceroute page to generate a Link Trace message from a specified MEP. The MEP can be specified by the MAC address, or by the remote MEP ID. To display the page, click Switching → Dot1ag → L2 Traceroute in the tree view. 772 Configuring Connectivity Fault Management Figure 26-11. Dot1ag L2 Traceroute Dot1ag L2 Traceroute Cache Use the L2 Traceroute Cache page to view link traces retained in the link trace database. To display the page, click Switching → Dot1ag → L2 Traceroute Cache in the tree view. Figure 26-12. Dot1ag L2 Traceroute Cache Configuring Connectivity Fault Management 773 Dot1ag Statistics Use the Statistics page to view Dot1ag information for a selected domain and VLAN ID. To display the page, click Switching → Dot1ag → Statistics in the tree view. Figure 26-13. 774 Dot1ag Statistics Configuring Connectivity Fault Management Configuring Dot1ag (CLI) This section provides information about the commands you use to configure Dot1ag settings on the switch. For more information about the commands, see the PowerConnect 7000 Series CLI Reference Guide at support.dell.com/manuals. Configuring Dot1ag Global Settings and Creating Domains Beginning in Privileged Exec mode, use the following commands to configure CFM settings and to view global status and domain information. CLI Command Description configure Enter global configuration mode. ethernet cfm enable Enables connectivity fault management services. ethernet cfm mep archivehold-time time Set the time interval (range: 1–65535 seconds) after which inactive RMEPs are removed. ethernet cfm cc level level vlan Configure the Continuity Check Message (CCM) vlan-id interval {1 | 10 | 60 | transmit interval for the specified VLAN. 600} ethernet cfm domain name level level Create a maintenance domain (MD) by assigning a name and level (0–7), and enter Maintenance Domain Config mode for that MD. service name vlan vlan-id Create a maintenance association (MA) within the current MD by associating it with a VLAN and naming the association (as a service instance). exit Exit to privileged Exec Mode show ethernet cfm domain brief Display the configured parameters in the Maintenance Domain. Configuring Connectivity Fault Management 775 Configuring MEP Information Beginning in Privileged Exec mode, use the following commands to configure the mode and view related settings. CLI Command Description configure Enter global configuration mode. interface interface Enter Interface Config mode for the specified interface, where interface is replaced by gigabitethernet unit/slot/port, or tengigabitethernet unit/slot/port. ethernet cfm mep enable level Define the port as a maintenance endpoint (MEP) level vlan vlan-id mpid mep-id and associate it with an SVLAN in a domain. When the MEP is enabled, it will generate CCM messages. ethernet cfm mep level level direction {up | down} mpid mep-id vlan vlan-id Enable a MEP at the specified level and direction. ethernet cfm mep active Set the administrative state of the MEP to active. ethernet cfm mip level level Create a MIP at the specified level on the interface. exit Exit to privileged Exec Mode show ethernet cfm maintenance–points Add the keywords local domain, local interface, local level, remote domain, or remote level to show information on local or remote endpoints. show ethernet cfm statistics Display statistics per MEP. 776 Configuring Connectivity Fault Management Dot1ag Ping and Traceroute Beginning in Privileged Exec mode, use the following commands to help identify and troubleshoot Ethernet CFM settings. CLI Command Description ping ethernet cfm mac mac- addr Generate a loopback message from the MEP with the specified MAC address. ping ethernet cfm remote–mpid mep-id Generate a loopback message from the MEP with the specified MEP ID. traceroute ethernet cfm mac mac-addr Generate a Link Trace message from the MEP with the specified MAC address. traceroute ethernet cfm remote–mpid mep-id Generate a Link Trace message from the MEP with the specified MEP ID. show ethernet cfm traceroute–cache Show the link trace database. Configuring Connectivity Fault Management 777 Dot1ag Configuration Example In the following example, the switch at the customer site is part of a Metro Ethernet network that is bridged to remote sites through a provider network. A service VLAN (SVID 200) identifies a particular set of customer traffic on the provider network. Figure 26-14. Dot1ag Configuration for a Metro Ethernet Customer Network To configure the switch: 1 Enable CFM globally on the switch, and then create a level-6 management domain named CustDom for end-to-end CFM on the Metro Ethernet network. VLAN 200 is associated with this domain. console#config console(config)#ethernet cfm enable console(config)#ethernet cfm domain CustDom level 6 console(config-cfm-mdomain)#service vlan vlan 200 console(config-cfm-mdomain)#exit 778 Configuring Connectivity Fault Management 2 Configure port 1/0/5 as an MEP for service VLAN 200 so that the port can exchange CFM PDUs with its counterpart MEPs on the customer network. The port is first configured as a MEP with MEP ID 20 on domain level 6 for VLAN 200. Then the port is enabled and activated as a MEP. console(config)#interface gigabitethernet 1/0/5 console(config-if-Gi1/0/5)#ethernet cfm mep level 6 direction down mpid 20 vlan 200 console(config-if-Gi1/0/5)#ethernet cfm mep enabled level 6 vlan 200 mpid 20 console(config-if-Gi1/0/5)#ethernet cfm mep active level 6 vlan 200 mpid 20 console(config-if-Gi1/0/5)#exit 3 On an intermediate switch, configure the MIP for the customer domain and enable CFM services on the CustDom domain to include local network devices. Configuring Connectivity Fault Management 779 780 Configuring Connectivity Fault Management 27 Snooping and Inspecting Traffic This chapter describes Dynamic Host Configuration Protocol (DHCP) Snooping, IP Source Guard (IPSG), and Dynamic ARP Inspection (DAI), which are layer 2 security features that examine traffic to help prevent accidental and malicious attacks on the switch or network. The topics covered in this chapter include: • Traffic Snooping and Inspection Overview • Default Traffic Snooping and Inspection Values • Configuring Traffic Snooping and Inspection (Web) • Configuring Traffic Snooping and Inspection (CLI) • Traffic Snooping and Inspection Configuration Examples Traffic Snooping and Inspection Overview DHCP Snooping is a security feature that monitors DHCP messages between a DHCP client and DHCP server to filter harmful DHCP messages and to build a bindings database. The IPSG and DAI features use the DHCP Snooping bindings database to help enforce switch and network security. IP Source Guard allows the switch to drop incoming packets that do not match a binding in the bindings database. Dynamic ARP Inspection allows the switch to drop ARP packets whose sender MAC address and sender IP address do not match an entry in the DHCP snooping bindings database. Snooping and Inspecting Traffic 781 What Is DHCP Snooping? Dynamic Host Configuration Protocol (DHCP) Snooping is a security feature that monitors DHCP messages between a DHCP client and DHCP server to accomplish the following tasks: • Filter harmful DHCP messages • Build a bindings database with entries that consist of the following information: • MAC address • IP address • VLAN ID • Client port Entries in the bindings database are considered to be authorized network clients. DHCP snooping can be enabled on VLANs, and the trust status (trusted or untrusted) is specified on individual physical ports or LAGS that are members of a VLAN. When a port or LAG is configured as untrusted, it could potentially be used to launch a network attack. DHCP servers must be reached through trusted ports. DHCP snooping enforces the following security rules: 782 • DHCP packets from a DHCP server (DHCPOFFER, DHCPACK, DHCPNAK, DHCPRELEASEQUERY) are dropped if they are received on an untrusted port. • DHCPRELEASE and DHCPDECLINE messages are dropped if the MAC addresses in the snooping database, but the binding's interface is other than the interface where the message was received. • On untrusted interfaces, the switch drops DHCP packets with a source MAC address that does not match the client hardware address. This is a configurable option. Snooping and Inspecting Traffic How Is the DHCP Snooping Bindings Database Populated? The DHCP snooping application uses DHCP messages to build and maintain the binding’s database. DHCP snooping creates a tentative binding from DHCP DISCOVER and REQUEST messages. Tentative bindings tie a client to a port (the port where the DHCP client message was received). Tentative bindings are completed when DHCP snooping learns the client’s IP address from a DHCP ACK message on a trusted port. DHCP snooping removes bindings in response to DECLINE, RELEASE, and NACK messages. The DHCP snooping application ignores the ACK messages as a reply to the DHCP Inform messages received on trusted ports. You can also enter static bindings into the binding database. When a switch learns of new bindings or loses bindings, the switch immediately updates the entries in the database. The switch also updates the entries in the binding file. The frequency at which the file is updated is based on a configurable delay, and the updates are batched. If the absolute lease time of the snooping database entry expires, that entry is removed. Make sure the system time is consistent across the reboots. Otherwise, the snooping entries will not expire properly. If a host sends a DHCP release while the switch is rebooting, when the switch receives the DHCP discovery or request, the client’s binding goes to the tentative binding as shown in Figure 27-1. Figure 27-1. DHCP Binding No Binding Discover Request Tentative Binding Release NACK Decline NACK Discover ACK Complete Binding The binding database includes data for clients only on untrusted ports. Snooping and Inspecting Traffic 783 DHCP Snooping and VLANs DHCP snooping forwards valid DHCP client messages received on nonrouting VLANs. The message is forwarded on all trusted interfaces in the VLAN. DHCP snooping can be configured on switching VLANs and routing VLANs. When a DHCP packet is received on a routing VLAN, the DHCP snooping application applies its filtering rules and updates the bindings database. If a client message passes filtering rules, the message is placed into the software forwarding path where it may be processed by the DHCP relay agent, the local DHCP server, or forwarded as an IP packet. DHCP Snooping Logging and Rate Limits The DHCP snooping application processes incoming DHCP messages. For DHCPRELEASE and DHCPDECLINE messages, the application compares the receive interface and VLAN with the client interface and VLAN in the bindings database. If the interfaces do not match, the application logs the event and drops the message. For valid client messages, DHCP snooping compares the source MAC address to the DHCP client hardware address. When there is a mismatch, DHCP snooping drops the packet and generates a log message if logging of invalid packets is enabled. If DHCP relay co-exists with DHCP snooping, DHCP client messages are sent to DHCP relay for further processing. To prevent DHCP packets from being used as a DoS attack when DHCP snooping is enabled, the snooping application enforces a rate limit for DHCP packets received on interfaces. DHCP snooping monitors the receive rate on each interface separately. If the receive rate exceeds a configurable limit, DHCP snooping brings down the interface. Administrative intervention is necessary to enable the port, either by using the no shutdown command in Interface Config mode or on the Switching → Ports → Port Configuration page. 784 Snooping and Inspecting Traffic What Is IP Source Guard? IPSG is a security feature that filters IP packets based on source ID. This feature helps protect the network from attacks that use IP address spoofing to compromise or overwhelm the network. The source ID may be either the source IP address or a {source IP address, source MAC address} pair. You can configure: • Whether enforcement includes the source MAC address • Static authorized source IDs The DHCP snooping bindings database and static IPSG entries identify authorized source IDs. IPSG can be enabled on physical and LAG ports. If you enable IPSG on a port where DHCP snooping is disabled or where DHCP snooping is enabled but the port is trusted, all IP traffic received on that port is dropped depending on the admin-configured IPSG entries. IPSG and Port Security IPSG interacts with port security, also known as port MAC locking, (see "Port Security (Port-MAC Locking)" on page 517) to enforce the source MAC address. Port security controls source MAC address learning in the layer 2 forwarding database (MAC address table). When a frame is received with a previously unlearned source MAC address, port security queries the IPSG feature to determine whether the MAC address belongs to a valid binding. If IPSG is disabled on the ingress port, IPSG replies that the MAC is valid. If IPSG is enabled on the ingress port, IPSG checks the bindings database. If the MAC address is in the bindings database and the binding matches the VLAN the frame was received on, IPSG replies that the MAC is valid. If the MAC is not in the bindings database, IPSG informs port security that the frame is a security violation. In the case of an IPSG violation, port security takes whatever action it normally takes upon receipt of an unauthorized frame. Port security limits the number of MAC addresses to a configured maximum. If the limit n is less than the number of stations m in the bindings database, port security allows only n stations to use the port. If n > m, port security allows only the stations in the bindings database. For information about configuring the Port Security feature, see "Configuring Port and System Security" on page 481. Snooping and Inspecting Traffic 785 What is Dynamic ARP Inspection? Dynamic ARP Inspection (DAI) is a security feature that rejects invalid and malicious ARP packets. DAI prevents a class of man-in-the-middle attacks where an unfriendly station intercepts traffic for other stations by poisoning the ARP caches of its unsuspecting neighbors. The malicious attacker sends ARP requests or responses mapping another station’s IP address to its own MAC address. When DAI is enabled, the switch drops ARP packets whose sender MAC address and sender IP address do not match an entry in the DHCP snooping bindings database. You can optionally configure additional ARP packet validation. When DAI is enabled on a VLAN, DAI is enabled on the interfaces (physical ports or LAGs) that are members of that VLAN. Individual interfaces are configured as trusted or untrusted. The trust configuration for DAI is independent of the trust configuration for DHCP snooping. Optional DAI Features If the network administrator has configured the option, DAI verifies that the sender MAC address equals the source MAC address in the Ethernet header. There is a configurable option to verify that the target MAC address equals the destination MAC address in the Ethernet header. This check applies only to ARP responses, since the target MAC address is unspecified in ARP requests. You can also enable IP address checking. When this option is enabled, DAI drops ARP packets with an invalid IP address. The following IP addresses are considered invalid: 786 • 0.0.0.0 • 255.255.255.255 • all IP multicast addresses • all class E addresses (240.0.0.0/4) • loopback addresses (in the range 127.0.0.0/8) Snooping and Inspecting Traffic Why Is Traffic Snooping and Inspection Necessary? DHCP Snooping, IPSG, and DAI are security features that can help protect the switch and the network against various types of accidental or malicious attacks. It might be a good idea to enable these features on ports that provide network access to hosts that are in physically unsecured locations or if network users connect nonstandard hosts to the network. For example, if an employee unknowingly connects a workstation to the network that has a DHCP server, and the DHCP server is enabled, hosts that attempt to acquire network information from the legitimate network DHCP server might obtain incorrect information from the rogue DHCP server. However, if the workstation with the rogue DHCP server is connected to a port that is configured as untrusted and is a member of a DHCP Snoopingenabled VLAN, the port discards the DHCP server messages. Default Traffic Snooping and Inspection Values DHCP snooping is disabled globally and on all VLANs by default. Ports are untrusted by default. Table 27-1. Traffic Snooping Defaults Parameter Default Value DHCP snooping mode Disabled DHCP snooping VLAN mode Disabled on all VLANs Interface trust state Disabled (untrusted) DHCP logging invalid packets Disabled DHCP snooping rate limit 15 packets per second DHCP snooping burst interval 1 second DHCP snooping binding database storage Local DHCP snooping binding database write delay 300 seconds Static DHCP bindings None configured IPSG mode Disabled on all interfaces IPSG port security Disabled on all interfaces Snooping and Inspecting Traffic 787 Table 27-1. Traffic Snooping Defaults (Continued) Parameter Default Value Static IPSG bindings None configured DAI validate source MAC Disabled DAI validate destination MAC Disabled DAI validate IP Disabled DAI trust state Disabled (untrusted) DAI Rate limit 15 packets per second DAI Burst interval 1 second DAI mode Disabled on all VLANs DAI logging invalid packets Disabled DAI ARP ACL None configured DAI Static flag Disabled (validation by ARP ACL and DHCP snooping binding database) 788 Snooping and Inspecting Traffic Configuring Traffic Snooping and Inspection (Web) This section provides information about the OpenManage Switch Administrator pages for configuring and monitoring DHCP snooping, IPSG, and DAI features on a PowerConnect 7000 Series switch. For details about the fields on a page, click at the top of the page. DHCP Snooping Configuration Use the DHCP Snooping Configuration page to control the DHCP Snooping mode on the switch and to specify whether the sender MAC Address for DHCP Snooping must be validated. To access the DHCP Snooping Configuration page, click Switching → DHCP Snooping → Global Configuration in the navigation panel. Figure 27-2. DHCP Snooping Configuration Snooping and Inspecting Traffic 789 DHCP Snooping Interface Configuration Use the DHCP Snooping Interface Configuration page to configure the DHCP Snooping settings on individual ports and LAGs. To access the DHCP Snooping Interface Configuration page, click Switching → DHCP Snooping → Interface Configuration in the navigation panel. Figure 27-3. DHCP Snooping Interface Configuration 790 Snooping and Inspecting Traffic To view a summary of the DHCP snooping configuration for all interfaces, click Show All. Figure 27-4. DHCP Snooping Interface Configuration Summary Snooping and Inspecting Traffic 791 DHCP Snooping VLAN Configuration Use the DHCP Snooping VLAN Configuration page to control the DHCP snooping mode on each VLAN. To access the DHCP Snooping VLAN Configuration page, click Switching → DHCP Snooping → VLAN Configuration in the navigation panel. Figure 27-5. DHCP Snooping VLAN Configuration 792 Snooping and Inspecting Traffic To view a summary of the DHCP snooping status for all VLANs, click Show All. Figure 27-6. DHCP Snooping VLAN Configuration Summary Snooping and Inspecting Traffic 793 DHCP Snooping Persistent Configuration Use the DHCP Snooping Persistent Configuration page to configure the persistent location of the DHCP snooping database. The bindings database can be stored locally on the switch or on a remote system somewhere else in the network. The switch must be able to reach the IP address of the remote system to send bindings to a remote database. To access the DHCP Snooping Persistent Configuration page, click Switching → DHCP Snooping → Persistent Configuration in the navigation panel. Figure 27-7. DHCP Snooping Persistent Configuration 794 Snooping and Inspecting Traffic DHCP Snooping Static Bindings Configuration Use the DHCP Snooping Static Bindings Configuration page to add static DHCP bindings to the binding database. To access the DHCP Snooping Static Bindings Configuration page, click Switching → DHCP Snooping → Static Bindings Configuration in the navigation panel. Figure 27-8. DHCP Snooping Static Bindings Configuration Snooping and Inspecting Traffic 795 To view a summary of the DHCP snooping status for all VLANs, click Show All. Figure 27-9. DHCP Snooping Static Bindings Summary To remove a static binding, select the Remove checkbox associated with the binding and click Apply. 796 Snooping and Inspecting Traffic DHCP Snooping Dynamic Bindings Summary The DHCP Snooping Dynamic Bindings Summary lists all the DHCP snooping dynamic binding entries learned on the switch ports. To access the DHCP Snooping Dynamic Bindings Summary page, click Switching → DHCP Snooping → Dynamic Bindings Summary in the navigation panel. Figure 27-10. DHCP Snooping Dynamic Bindings Summary Snooping and Inspecting Traffic 797 DHCP Snooping Statistics The DHCP Snooping Statistics page displays DHCP snooping interface statistics. To access the DHCP Snooping Statistics page, click Switching → DHCP Snooping → Statistics in the navigation panel. Figure 27-11. 798 DHCP Snooping Statistics Snooping and Inspecting Traffic IPSG Interface Configuration Use the IPSG Interface Configuration page to configure IPSG on an interface. To access the IPSG Interface Configuration page, click Switching → IP Source Guard → IPSG Interface Configuration in the navigation panel. Figure 27-12. IPSG Interface Configuration Snooping and Inspecting Traffic 799 IPSG Binding Configuration Use the IPSG Binding Configuration page displays DHCP snooping interface statistics. To access the IPSG Binding Configuration page, click Switching → IP Source Guard → IPSG Binding Configuration in the navigation panel. Figure 27-13. 800 IPSG Binding Configuration Snooping and Inspecting Traffic IPSG Binding Summary The IPSG Binding Summary page displays the IPSG Static binding list and IPSG dynamic binding list (the static bindings configured in Binding configuration page). To access the IPSG Binding Summary page, click Switching → IP Source Guard → IPSG Binding Summary in the navigation panel. Figure 27-14. IPSG Binding Summary Snooping and Inspecting Traffic 801 DAI Global Configuration Use the DAI Configuration page to configure global DAI settings. To display the DAI Configuration page, click Switching → Dynamic ARP Inspection → Global Configuration in the navigation panel. Figure 27-15. 802 Dynamic ARP Inspection Global Configuration Snooping and Inspecting Traffic DAI Interface Configuration Use the DAI Interface Configuration page to select the DAI Interface for which information is to be displayed or configured. To display the DAI Interface Configuration page, click Switching → Dynamic ARP Inspection → Interface Configuration in the navigation panel. Figure 27-16. Dynamic ARP Inspection Interface Configuration To view a summary of the DAI status for all interfaces, click Show All. Snooping and Inspecting Traffic 803 Figure 27-17. 804 DAI Interface Configuration Summary Snooping and Inspecting Traffic DAI VLAN Configuration Use the DAI VLAN Configuration page to select the VLANs for which information is to be displayed or configured. To display the DAI VLAN Configuration page, click Switching → Dynamic ARP Inspection → VLAN Configuration in the navigation panel. Figure 27-18. Dynamic ARP Inspection VLAN Configuration To view a summary of the DAI status for all VLANs, click Show All. Figure 27-19. Dynamic ARP Inspection VLAN Configuration Summary Snooping and Inspecting Traffic 805 DAI ACL Configuration Use the DAI ACL Configuration page to add or remove ARP ACLs. To display the DAI ACL Configuration page, click Switching → Dynamic ARP Inspection → ACL Configuration in the navigation panel. Figure 27-20. 806 Dynamic ARP Inspection ACL Configuration Snooping and Inspecting Traffic To view a summary of the ARP ACLs that have been created, click Show All. Figure 27-21. Dynamic ARP Inspection ACL Summary To remove an ARP ACL, select the Remove checkbox associated with the ACL and click Apply. DAI ACL Rule Configuration Use the DAI ARP ACL Rule Configuration page to add or remove DAI ARP ACL Rules. To display the DAI ARP ACL Rule Configuration page, click Switching → Dynamic ARP Inspection → ACL Rule Configuration in the navigation panel. Snooping and Inspecting Traffic 807 Figure 27-22. Dynamic ARP Inspection Rule Configuration To view a summary of the ARP ACL rules that have been created, click Show All. Figure 27-23. Dynamic ARP Inspection ACL Rule Summary To remove an ARP ACL rule, select the Remove checkbox associated with the rule and click Apply. 808 Snooping and Inspecting Traffic DAI Statistics Use the DAI Statistics page to display the statistics per VLAN. To display the DAI Statistics page, click Switching → Dynamic ARP Inspection → Statistics in the navigation panel. Figure 27-24. Dynamic ARP Inspection Statistics Snooping and Inspecting Traffic 809 Configuring Traffic Snooping and Inspection (CLI) This section provides information about the commands you use to configure DHCP snooping, IPSG, and DAI settings on the switch. For more information about the commands, see the PowerConnect 7000 Series CLI Reference Guide at support.dell.com/manuals. Configuring DHCP Snooping Beginning in Privileged EXEC mode, use the following commands to configure and view DHCP snooping settings. Command Purpose configure Enter global configuration mode. ip dhcp snooping Enable DHCP snooping on the switch. ip dhcp snooping verify Enable the verification of the source MAC address with mac-address the client MAC address in the received DHCP message. ip dhcp snooping loginvalid Enable the logging of DHCP messages filtered by the DHCP Snooping application. ip dhcp snooping binding mac-address vlan vlan-id ip-address interface interface Configure a static binding in the DHCP snooping static bindings database. • mac-address —The client's MAC address. • vlan-id —The number of the VLAN the client is authorized to use. • ip-address —The IP address of the client. • interface —The interface on which the client is authorized. The form is unit/port. ip dhcp snooping database {local | tftp://hostIP/filename } Configure the persistent storage location of the DHCP snooping database. • hostIP —The IP address of the remote host. • filename —The name of the file for the database on the remote host. ip dhcp snooping database write-delay seconds 810 Configure the interval, in seconds, at which the DHCP Snooping database will be stored in persistent storage. The number of seconds can range from 15–86400. Snooping and Inspecting Traffic Command Purpose ip dhcp snooping limit {none | rate rate [burst interval seconds]} Configure the maximum rate of DHCP messages allowed on the switch at any given time. • rate —The maximum number of packets per second allowed (Range: 0–300 pps). • seconds —The time allowed for a burst (Range: 1–15 seconds). interface interface Enter interface configuration mode for the specified port or LAG. The interface variable includes the interface type and number, for example gigabitethernet 1/0/3. For a LAG, the interface type is port-channel. You can also specify a range of ports with the interface range command, for example, interface range gigabitethernet 1/0/8-12 configures interfaces 8, 9, 10, 11, and 12. ip dhcp snooping trust Configure the interface (or range of interfaces) as a trusted port. DHCP server messages are not filtered on trusted ports. exit Exit to Global Configuration mode. vlan id interface [range] vlan Enter interface configuration mode for the specified VLAN or range of VLANs. CTRL + Z Exit to Privileged EXEC mode. show ip dhcp snooping [interfaces] View the DHCP snooping global and per port configuration. show ip dhcp snooping binding [{static | dynamic}] [interface port] [vlan vlan-id] View the entries in the DHCP snooping bindings database. show ip dhcp snooping database View information about the persistent database configuration. show ip dhcp snooping statistics View the DHCP snooping statistics. clear ip dhcp snooping statistics Reset the DHCP snooping statistics to zero. Snooping and Inspecting Traffic 811 Configuring IP Source Guard Beginning in Privileged EXEC mode, use the following commands to configure IPSG settings on the switch. Command Purpose configure Enter global configuration mode. interface interface Enter interface configuration mode for the specified port or LAG. The interface variable includes the interface type and number, for example gigabitethernet 1/0/3. For a LAG, the interface type is port-channel. You can also specify a range of ports with the interface range command, for example, interface range gigabitethernet 1/0/8-12 configures interfaces 8, 9, 10, 11, and 12. ip verify source [portsecurity] Enable IPSG on the port or LAG to prevent packet forwarding if the source IP address in the packet is not in the DHCP snooping binding database. Use the option port-security keyword to also prevent packet forwarding if the sender MAC address is not in forwarding database table or the DHCP snooping binding database. \ NOTE: To enforce filtering based on the source MAC address, port security must also be enabled on the interface by using the port security command in Interface Configuration mode. exit Exit to Global Config mode. ip verify binding Configure a static binding for IPSG. mac_addr vlan vlan_id ipaddr interface interface exit Exit to Privileged EXEC mode. show ip verify interface View IPSG parameters for a specific port or LAG. The interface parameter includes the interface type (gigabitethernet, tengigabitethernet, or port-channel) and number. show ip verify source [interface interface] View IPSG bindings configured on the switch or on a specific port or LAG. show ip source binding View IPSG bindings. interface 812 Snooping and Inspecting Traffic Configuring Dynamic ARP Inspection Beginning in Privileged EXEC mode, use the following commands to configure DAI settings on the switch. Command Purpose configure Enter global configuration mode. ip arp inspection vlan vlan-range [logging] Enable Dynamic ARP Inspection on a single VLAN or a range of VLANs. Use the logging keyword to enable logging of invalid packets. ip arp inspection Enable additional validation checks like source MAC validate {[src-mac] [dst- address validation, destination MAC address validation, or mac] [ip]} IP address validation on the received ARP packets. Each command overrides the configuration of the previous command. For example, if a command enables source MAC address and destination validations and a second command enables IP address validation only, the source MAC address and destination MAC address validations are disabled as a result of the second command. • src-mac—For validating the source MAC address of an ARP packet. • dst-mac—For validating the destination MAC address of an ARP packet. • ip—For validating the IP address of an ARP packet. arp access-list acl-name Create an ARP ACL with the specified name (1–31 characters) and enter ARP Access-list Configuration mode for the ACL. permit ip host sender-ip mac host sender-mac Configure a rule for a valid IP address and MAC address combination used in ARP packet validation. • sender-ip — Valid IP address used by a host. • sender-mac —Valid MAC address in combination with the above sender-ip used by a host. exit Exit to Global Config mode. Snooping and Inspecting Traffic 813 Command Purpose Configure the ARP ACL to be used for a single VLAN or a ip arp inspection filter acl-name vlan vlan-range range of VLANs to filter invalid ARP packets. [static] Use the static keyword to indicate that packets that do not match a permit statement are dropped without consulting the DHCP snooping bindings. interface interface Enter interface configuration mode for the specified port or LAG. The interface variable includes the interface type and number, for example gigabitethernet 1/0/3. For a LAG, the interface type is port-channel. You can also specify a range of ports with the interface range command, for example, interface range gigabitethernet 1/0/8-12 configures interfaces 8, 9, 10, 11, and 12. ip arp inspection limit {none | rate pps [burst interval seconds ]} Configure the rate limit and burst interval values for an interface.Use the keyword none to specify that the interface is not rate limited for Dynamic ARP Inspection. • none — To set no rate limit. • pps — Packets per second (Range: 0–300). • seconds — The number of seconds (Range: 1–15). ip arp inspection trust Specify that the interface as trusted for Dynamic ARP Inspection. CTRL + Z Exit to Privileged EXEC mode. show ip arp inspection interfaces [interface] View the Dynamic ARP Inspection configuration on all the DAI-enabled interfaces or for the specified interface. show ip arp inspection vlan [vlan-range ] View the Dynamic ARP Inspection configuration on the specified VLAN(s). This command also displays the global configuration values for source MAC validation, destination MAC validation and invalid IP validation. show ip arp inspection statistics [vlan vlanrange] View the statistics of the ARP packets processed by Dynamic ARP Inspection for the switch or for the specified VLAN(s). show arp access-list [acl- View all configured ARP ACL and their rules, or use the ACL name to view information about that ARP ACL only. name] 814 Snooping and Inspecting Traffic Traffic Snooping and Inspection Configuration Examples This section contains the following examples: • Configuring DHCP Snooping • Configuring IPSG Configuring DHCP Snooping In this example, DHCP snooping is enabled on VLAN 100. Ports 1-20 connect end users to the network and are members of VLAN 100. These ports are configured to limit the maximum number of DHCP packets with a rate limit of 100 packets per second. LAG 1, which is also a member of VLAN 100 and contains ports 21-24, is the trunk port that connects the switch to the data center, so it is configured as a trusted port. Figure 27-25. DHCP Snooping Configuration Topology The commands in this example also enforce rate limiting and remote storage of the bindings database. The switch has a limited amount of storage space in NVRAM and flash memory, so the administrator specifies that the DHCP snooping bindings database is stored on an external TFTP server. Snooping and Inspecting Traffic 815 To configure the switch: 1 Enable DHCP snooping on VLAN 100. console#config console(config)#ip dhcp snooping vlan 100 2 Configure LAG 1, which includes ports 21-24, as a trusted port. All other interfaces are untrusted by default. console(config)#interface port-channel 1 console(config-if-Po1)#ip dhcp snooping trust console(config-if-Po1)#exit 3 Enter interface configuration mode for all untrusted interfaces (ports 120) and limit the number of DHCP packets that an interface can receive to 100 packets per second. LAG 1 is a trusted port and keeps the default value for rate limiting (unlimited). console(config)#interface range gi1/0/1-20 console(config-if)#ip dhcp snooping limit rate 100 console(config-if)#exit 4 Specify that the DHCP snooping database is to be stored remotely in a file called dsDb.txt on a TFTP server with and IP address of 10.131.11.1. console(config)#ip dhcp snooping database tftp://10.131.11.1/dsDb.txt console(config)#exit 5 Enable DHCP snooping for the switch console(config)#ip dhcp snooping 6 View DHCP snooping information. console#show ip dhcp snooping DHCP snooping is Enabled DHCP snooping source MAC verification is enabled DHCP snooping is enabled on the following VLANs: 100 Interface ----------- 816 Trusted ---------- Snooping and Inspecting Traffic Log Invalid Pkts ---------------- Configuring IPSG This example builds on the previous example and uses the same topology shown in Figure 27-25. In this configuration example, IP source guard is enabled on ports 1-20. DHCP snooping must also be enabled on these ports. Additionally, because the ports use IP source guard with source IP and MAC address filtering, port security must be enabled on the ports as well. To configure the switch: 1 Enter interface configuration mode for the host ports and enable IPSG. console(config)#interface range gi1/0/1-20 console(config-if)#ip verify source port-security 2 Enable port security on the ports. console(config-if)#port security 3 View IPSG information. console#show ip verify source Interface Filter --------- ------Gi1/0/1 ip-mac Gi1/0/2 ip-mac Gi1/0/3 ip-mac Gi1/0/4 ip-mac Gi1/0/5 ip-mac --More-- or (q)uit IP Address ---------192.168.3.45 192.168.3.40 192.168.3.33 192.168.3.18 192.168.3.49 MAC Address Vlan 00:1C:23:55:D4:8E 00:1C:23:12:44:B6 00:1C:23:AA:B8:01 00:1C:23:67:D3:CC 00:1C:23:55:1B:6E 100 100 100 100 100 Snooping and Inspecting Traffic 817 818 Snooping and Inspecting Traffic 28 Configuring Link Aggregation This chapter describes how to create and configure link aggregation groups (LAGs), which are also known as port channels. The topics covered in this chapter include: • Link Aggregation Overview • Default Link Aggregation Values • Configuring Link Aggregation (Web) • Configuring Link Aggregation (CLI) • Link Aggregation Configuration Examples Link Aggregation Overview Link Aggregation allows one or more full-duplex (FDX) Ethernet links of the same speed to be aggregated together to form a LAG. This allows the switch to treat the LAG as if it is a single link. The PowerConnect 7000 Series switches support industry-standard LAGs that adhere to the IEEE 802.3ad specification. The maximum number of LAGs that may be configured is limited to the maximum number of ports possible in the switch stack or stand-alone switch divided by two. This allows for a flexible configuration of LAGs where LAGs may have up to eight ports or as few as two ports. You can configure LAGs until all ports in the system are assigned to a LAG. Assignment of interfaces to dynamic LAGs is based on a maximum of 144 interfaces assigned to dynamic LAGs, a maximum of 72 dynamic LAGs and a maximum of 8 interfaces per dynamic LAG. For example, 72 LAGs may be assigned 2 interfaces each, or 18 LAGs may be assigned 8 interfaces each. Each LAG can consist of up to eight 1 Gbps or eight 10 Gbps ports. When eight Gigabit Ethernet ports are configured as a LAG, the maximum bandwidth for the single, logical interface is 8 Gbps, and when eight 10 Gbps ports are configured as a LAG, the maximum bandwidth for the single, logical interface is 80 Gbps. Configuring Link Aggregation 819 Figure 28-1 shows an example of a switch in the wiring closet connected to a switch in the data center by a LAG that consists of four physical 1 Gbps links. The LAG provides full-duplex bandwidth of 4 Gbps between the two switches. Figure 28-1. LAG Configuration LAGs can be configured on stand-alone or stacked switches. In a stack of switches, the LAG can consist of ports on a single unit or across multiple stack members. When a LAG members span different units across a stack, and a unit fails, the remaining LAG members on the functional units continue to handle traffic for the LAG. Why Are Link Aggregation Groups Necessary? The primary purpose of LAGs is to increase the overall bandwidth between two switches. This is accomplished by effectively aggregating multiple ports together that act as a single, logical connection between the two switches. LAGs also provide redundancy. If a link fails, traffic is automatically redistributed across the remaining links. What Is the Difference Between Static and Dynamic Link Aggregation? Link aggregation can be configured as either dynamic or static. Dynamic configuration is supported using the IEEE 802.3ad standard, which is known as Link Aggregation Control Protocol (LACP). Static configuration is used when connecting a PowerConnect 7000 Series switch to an external Gigabit Ethernet switch that does not support LACP. One advantage of LACP is that the protocol enables the switch to confirm that the external switch is also configured for link aggregation. When using static configuration, a cabling or configuration mistake involving the 7000 820 Configuring Link Aggregation Series switch or the external switch could go undetected and thus cause undesirable network behavior. Both static and dynamic LAGs (via LACP) can detect physical link failures within the LAG and continue forwarding traffic through the other connected links within that same LAG. LACP can also detect switch or port failures that do not result in loss of link. This provides a more resilient LAG. Best practices suggest using dynamic link aggregation instead of static link aggregation.When a port is added to a LAG as a static member, it neither transmits nor receives LACP PDUs. What is LAG Hashing? PowerConnect 7000 Series switches support configuration of hashing algorithms for each LAG interface. The hashing algorithm is used to distribute traffic load among the physical ports of the LAG while preserving the per-flow packet order. The hashing algorithm uses various packet attributes to determine the outgoing physical port. The switch supports the following set of packet attributes to be used for hash computation: • Source MAC, VLAN, EtherType, and incoming port. • Destination MAC, VLAN, EtherType, and incoming port. • Source IP and Source TCP/UDP port numbers. • Destination IP and Destination TCP/UDP port numbers. • Source/Destination MAC, VLAN, EtherType, and incoming port. • Source/Destination IP and Source/Destination TCP/UDP port numbers. • Enhanced hashing mode Enhanced hashing mode has following advantages: • MODULO-N operation based on the number of ports in the LAG. • Packet attributes selection based on the packet type. For L2 packets, Source and Destination MAC address are used for hash computation. For IP packets, Source IP, Destination IP address, TCP/UDP ports are used. • Non-Unicast traffic and Unicast traffic is hashed using a common hash algorithm. • Excellent load balancing performance. Configuring Link Aggregation 821 How Do LAGs Interact with Other Features? From a system perspective, a LAG is treated just as a physical port, with the same configuration parameters for administrative enable/disable, spanning tree port priority, path cost as may be for any other physical port. VLAN When members are added to a LAG, they are removed from all existing VLAN membership. When members are removed from a LAG they are added back to the VLANs that they were previously members of as per the configuration file. Note that a port’s VLAN membership can still be configured when it's a member of a LAG. However this configuration is only actually applied when the port leaves the LAG. The LAG interface can be a member of a VLAN complying with IEEE 802.1Q. STP Spanning tree does not maintain state for members of a LAG, but the Spanning Tree does maintain state for the LAG interface. As far as STP is concerned, members of a LAG do not exist. (Internally, the STP state of the LAG interface is replicated for the member links.) When members are deleted from a LAG they become normal links, and spanning tree maintains their state information. Statistics Statistics are maintained for all LAG interfaces as they are done for the physical ports, besides statistics maintained for individual members as per the 802.3ad MIB statistics. 822 Configuring Link Aggregation LAG Configuration Guidelines Ports to be aggregated must be configured so that they are compatible with the link aggregation feature and with the partner switch to which they connect. Ports to be added to a LAG must meet the following requirements: • Interface must be a physical Ethernet link. • Each member of the LAG must be running at the same speed and must be in full duplex mode. • The port cannot be a mirrored port The following are the interface restrictions • The configured speed of a LAG member cannot be changed. • An interface can be a member of only one LAG. Default Link Aggregation Values The LAGs on the switch are created by default, but no ports are members. Table 28-1 summarizes the default values for the MAC address table. Table 28-1. MAC Address Table Defaults Parameter Default Value LACP system priority 1 LACP port priority 1 LACP timeout Long LAG hash algorithm type Source IP and source TCP/UDP port Configuring Link Aggregation 823 Configuring Link Aggregation (Web) This section provides information about the OpenManage Switch Administrator pages for configuring and monitoring LAGs on a PowerConnect 7000 Series switch. For details about the fields on a page, click at the top of the page. LAG Configuration Use the LAG Configuration page to set the name and administrative status (up/down) of a LAG. To display the LAG Configuration page, click Switching → Ports → LAG Configuration in the navigation panel. Figure 28-2. LAG Configuration 824 Configuring Link Aggregation LACP Parameters Dynamic link aggregation is initiated and maintained by the periodic exchanges of LACP PDUs. Use the LACP Parameters page to configure LACP LAGs. To display the LACP Parameters page, click Switching → Link Aggregation → LACP Parameters in the navigation panel. Figure 28-3. LACP Parameters Configuring LACP Parameters for Multiple Ports To configure LACP settings: 1 Open the LACP Parameters page. 2 Click Show All. The LACP Parameters Table page displays. Configuring Link Aggregation 825 Figure 28-4. LACP Parameters Table 3 Select the Edit check box associated with each port to configure. 4 Specify the LACP port priority and LACP timeout for each port. 5 Click Apply. 826 Configuring Link Aggregation LAG Membership Your switch supports 48 LAGs per system, and eight ports per LAG. Use the LAG Membership page to assign ports to static and dynamic LAGs. To display the LAG Membership page, click Switching → Link Aggregation → LAG Membership in the navigation panel. Figure 28-5. LAG Membership Adding a Port to a Static LAG To add a static LAG member: 1 Open the LAG Membership page. 2 Click in the LAG row to toggle the port to the desired LAG. The LAG number displays for that port. The LAG number increases each time you click until the number reaches the maximum LAG number and then returns to blank (no LAG assigned). 3 Click Apply. The port is assigned to the selected LAG, and the device is updated. Configuring Link Aggregation 827 Adding a LAG Port to a Dynamic LAG by Using LACP To add a dynamic LAG member: 1 Open the LAG Membership page. 2 Click in the LACP row to toggle the desired LAG port to L. NOTE: The port must be assigned to a LAG before it can be aggregated to an LACP. 3 Click Apply. The LAG port is added as a dynamic LAG member to the selected LAG. LAG Hash Configuration Use the LAG hash algorithm to set the traffic distribution mode on the LAG. You can set the hash type for each LAG. To display the LAG Hash Configuration page, click Switching → Link Aggregation → LAG Hash Configuration in the navigation panel. Figure 28-6. LAG Hash Configuration 828 Configuring Link Aggregation LAG Hash Summary The LAG Hash Summary page lists the channels on the system and their assigned hash algorithm type. To display the LAG Hash Summary page, click Switching → Link Aggregation → LAG Hash Summary in the navigation panel. Figure 28-7. LAG Hash Summary Configuring Link Aggregation 829 Configuring Link Aggregation (CLI) This section provides information about the commands you use to configure link aggregation settings on the switch. For more information about the commands, see the PowerConnect 7000 Series CLI Reference Guide at support.dell.com/manuals. Configuring LAG Characteristics Beginning in Privileged EXEC mode, use the following commands to configure a few of the available LAG characteristics. Many of the commands described in "Configuring Port Characteristics (CLI)" on page 475 are also applicable to LAGs. Command Purpose configure Enter global configuration mode. interface interface Enter interface configuration mode for the specified LAG. The interface variable includes the interface type, which is port-channel, and the LAG number, for example portchannel 3. You can also specify a range of LAGs with the interface range port-channel command, for example, interface range port-channel 3-6 configures LAGs 3, 4, 5, and 6. description description Configure a description for the LAG or range of LAGs minimum port-channel min-links Set the minimum number of links that must be up in order for the port channel interface to be declared up. exit Exit to Global Config mode. CTRL + Z Exit to Privileged EXEC mode. show interfaces View the configured description for the specified LAG. description port-channel port-channel number show interfaces portchannel [port-channel number] 830 View LAG information for the specified LAG or for all LAGs. Configuring Link Aggregation Configuring Link Aggregation Groups Beginning in Privileged EXEC mode, use the following commands to add ports as LAG members and to configure the LAG hashing mode. Command Purpose configure Enter global configuration mode. interface interface Enter interface configuration mode for the specified port. The interface variable includes the interface type and number, for example gigabitethernet 1/0/3. You can also specify a range of ports with the interface range command, for example, interface range gigabitethernet 1/0/8-12 configures interfaces 8, 9, 10, 11, and 12. channel-group portchannel-number mode {on | auto} Add the port(s) to the LAG specified with the portchannel-number value. Use the auto keyword to add the port(s) as dynamic members, or use on to specify that the LAG membership is static. • port-channel-number — Number of a valid port-channel for the current port to join. • on — Forces the port to join a channel without LACP (static LAG). • active — Forces the port to join a channel with LACP (dynamic LAG). exit Exit to Global Config mode. interface port-channel Enter interface configuration mode for the specified LAG. number You can also specify a range of LAGs to configure with the interface range port-channel command, for example, interface range port-channel 1-3,10 configures LAGs 1, 2, 3, and 10. Configuring Link Aggregation 831 Command Purpose hashing-mode mode Set the hashing algorithm on the LAG. The mode value is a number from 1 to 7. The numbers correspond to the following algorithms: • 1 — Source MAC, VLAN, EtherType, source module, and port ID • 2 — Destination MAC, VLAN, EtherType, source module, and port ID • 3 — Source IP and source TCP/UDP port • 4 — Destination IP and destination TCP/UDP port • 5 — Source/destination MAC, VLAN, EtherType, and source MODID/port • 6 — Source/destination IP and source/destination TCP/UDP port • 7 — Enhanced hashing mode CTRL + Z Exit to Privileged EXEC mode. show interfaces portchannel [port-channel number] View LAG information for the specified LAG or for all LAGs. show statistics portchannel port-channel- View interface statistics for the specified LAG. number 832 Configuring Link Aggregation Configuring LACP Parameters Beginning in Privileged EXEC mode, use the following commands to configure system and per-port LACP parameters. Command Purpose configure Enter global configuration mode. lacp system-priority value Set the Link Aggregation Control Protocol priority for the switch. the priority value range is 1–65535. interface port-channel Enter interface configuration mode for the specified LAG. number You can also specify a range of LAGs to configure with the interface range port-channel command, for example, interface range port-channel 1-3,10 configures LAGs 1, 2, 3, and 10. lacp port-priority value Set the Link Aggregation Control Protocol priority for the port or range of ports. The priority value range is 1–65535. lacp timeout {long | short} Specify whether to wait a long or short time between LACP PDU transmissions. exit Exit to Privileged EXEC mode. show lacp interface View LACP parameters for an Ethernet interface or a LAG. The interface parameter includes the interface type (gigabitethernet, tengigabitethernet, or port-channel) and number. Configuring Link Aggregation 833 Link Aggregation Configuration Examples This section contains the following examples: • Configuring Dynamic LAGs • Configuring Static LAGs NOTE: The examples in this section show the configuration of only one switch. Because LAGs involve physical links between two switches, the LAG settings and member ports must be configured on both switches. Configuring Dynamic LAGs The commands in this example show how to configure a static LAG on a switch. The LAG number is 1, and the member ports are 1, 2, 3, 6, and 7. To configure the switch: 1 Enter interface configuration mode for the ports that are to be configured as LAG members. console(config)#interface range gi1/0/1-3,gi1/0/6-7 2 Add the ports to LAG 2 with LACP. console(config-if)#channel-group 1 mode active 3 View information about LAG 1. console#show interfaces port-channel 1 Channel ------Po1 834 Ports Hash Algorithm ----------------- -------------Inactive: Gi1/0/1, 3 Gi1/0/2, Gi1/0/3, Gi1/0/6, Gi1/0/7 Configuring Link Aggregation Ch-Type min-links ------- --------Dynamic 1 Configuring Static LAGs The commands in this example show how to configure a static LAG on a switch. The LAG number is 2, and the member ports are 10, 11, 14, and 17. To configure the switch: 1 Enter interface configuration mode for the ports that are to be configured as LAG members. console(config)#interface range gi1/0/10-12, gi1/0/14,gi1/0/17 2 Add the ports to LAG 2 without LACP. console(config-if)#channel-group 2 mode on 3 View information about LAG 2. console#show interfaces port-channel 2 Channel Ports Hash Algorithm Ch-Type min-links ------- ------------------------------ ------- --------Po2 Inactive: Gi1/0/10, 3 Static 1 Gi1/0/11, Gi1/0/12, Gi1/0/14, Gi1/0/17 Configuring Link Aggregation 835 836 Configuring Link Aggregation 29 Managing the MAC Address Table This chapter describes the L2 MAC address table the switch uses to forward data between ports. The topics covered in this chapter include: • MAC Address Table Overview • Default MAC Address Table Values • Managing the MAC Address Table (Web) • Managing the MAC Address Table (CLI) MAC Address Table Overview The MAC address table keeps track of the MAC addresses that are associated with each port to allow the switch to forward unicast traffic through the appropriate port. This table is sometimes called the bridge table or the forwarding database. How Is the Address Table Populated? The MAC address table can contain two types of addresses: • Static: The address has been manually configured and does not age out. • Dynamic: The address has been automatically learned by the switch and can age out when it is not in use. Static addresses are configured by the administrator and added to the table. Dynamic addresses are learned by examining information in the Ethernet frame. When a frame arrives on a port, the switch looks at the frame header to learn the source MAC address of the frame, then adds the address, VLAN ID, and the ingress port to the MAC address table. The address table is constantly updated as new addresses are learned, and unused addresses age out. A frame that has a destination MAC address that matches an entry in the table is forwarded immediately to the associated port(s)/VLAN(s). Managing the MAC Address Table 837 What Information Is in the MAC Address Table? Each entry in the address table, whether it is static or dynamic, includes the MAC address, the VLAN ID associated with the MAC address, and the interface on which the address was learned or configured. Each port can maintain multiple MAC addresses, and a MAC address can be associated with multiple VLANs. How Is the MAC Address Table Maintained Across a Stack? The MAC address table is synchronized across all stack members. When a member joins the stack, its previous MAC address table is overwritten by the table maintained by the stack. Default MAC Address Table Values Table 29-1 summarizes the default values for the MAC address table. Table 29-1. MAC Address Table Defaults Parameter Default Value Aging time 300 seconds Dynamic addresses Enabled (automatically learned) Static addresses None configured 838 Managing the MAC Address Table Managing the MAC Address Table (Web) This section provides information about the OpenManage Switch Administrator pages to use to manage the MAC address table on a PowerConnect 7000 Series switch. For details about the fields on a page, click at the top of the page. Static Address Table Use the Static Address Table page to view MAC addresses that have been manually added to the MAC address table and to configure static MAC addresses. To display the Static Address Table page, click Switching → Address Tables → Static Address Table in the navigation panel. Figure 29-1. Static MAC Address Adding a Static MAC Address To add a static MAC address: 1 Open the Static MAC Address page. 2 Click Add. The Add Static MAC Address page displays. Managing the MAC Address Table 839 Figure 29-2. Adding Static MAC Address 3 Select the interface to associate with the static address. 4 Specify the MAC address and an associated VLAN ID. 5 Click Apply. The new static address is added to the Static MAC Address Table, and the device is updated. 840 Managing the MAC Address Table Dynamic Address Table The Dynamic Address Table page contains fields for querying information in the dynamic address table, including the interface type, MAC addresses, VLAN, and table sorting key. Packets forwarded to an address stored in the address table are forwarded directly to those ports. The Dynamic Address Table also contains information about the aging time before a dynamic MAC address is removed from the table. To display the Dynamic Address Table, click Switching → Address Tables → Dynamic Address Table in the navigation panel. Figure 29-3. Dynamic Address Table Managing the MAC Address Table 841 Managing the MAC Address Table (CLI) This section provides information about the commands you use to manage the MAC address table on the switch. For more information about the commands, see the PowerConnect 7000 Series CLI Reference Guide at support.dell.com/manuals. Managing the MAC Address Table Beginning in Privileged EXEC mode, use the following commands to add a static MAC address to the table, control the aging time for dynamic addresses, and view entries in the MAC address table. Command Purpose configure Enter global configuration mode. mac address-table static Add a static MAC source address to the MAC address table. mac-address vlan vlan-id • mac-address — A valid MAC address in the format interface interface xxxx.xxxx.xxxx. • vlan-id —A valid VLAN. • interface — A valid port or LAG, including the interface type and number. mac address-table aging-time {0 | 101000000} Specify the number of seconds that must pass before an unused dynamically-learned MAC address is removed from the MAC address table. A value of 0 disables the aging time for the MAC address table. exit Exit to Privileged EXEC mode. show mac address-table View information about the entries in the MAC address [static | dynamic] table. Use the keywords static or dynamic to specify the address type to view. For dynamic entries, you can use the clear mac addresstable command to remove entries from the table. show mac address-table View information about the MAC addresses that have been configured or learned on the switch, a specific VLAN, or an {vlan vlan | interface interface [vlan vlan-id]} interface (Ethernet port or LAG/port-channel). show mac address-table View information about the number of addresses that have been configured or learned on the switch, a specific VLAN, count [{vlan vlan-id or an interface (Ethernet port or LAG/port-channel). |interface interface}] 842 Managing the MAC Address Table 30 Configuring Routing Interfaces This chapter describes the routing (layer 3) interfaces the PowerConnect 7000 Series switches support, which includes VLAN routing interfaces, loopback interfaces, and tunnel interfaces. The topics covered in this chapter are: • Routing Interface Overview • Default Routing Interface Values • Configuring Routing Interfaces (Web) • Configuring Routing Interfaces (CLI) For information about configuring IPv6 characteristics on routing interfaces, see "Configuring IPv6 Routing" on page 1057. For configuration examples that configure VLAN routing interfaces, see "IP Routing Configuration Example" on page 904 in the Configuring IP Routing chapter. For a configuration example that includes tunnel and loopback interface creation, see "Interconnecting an IPv4 Backbone and Local IPv6 Network" on page 1006. Routing Interface Overview Routing interfaces are logical interfaces that can be configured with an IP address. Routing interfaces provide a means of transmitting IP packets between subnets on the network. What Are VLAN Routing Interfaces? VLANs divide a single physical network (broadcast domain) into separate logical networks. To forward traffic across VLAN boundaries, a layer 3 device, such as router, is required. PowerConnect 7000 Series switches can act as layer 3 devices when you configure VLAN routing interfaces. VLAN routing interfaces make it possible to transmit traffic between VLANs while still containing broadcast traffic within VLAN boundaries. The configuration of VLAN routing interfaces makes inter-VLAN routing possible. Configuring Routing Interfaces 843 For each VLAN routing interface you can assign a static IP address, or you can allow a network DHCP server to assign a dynamic IP address. When a port is enabled for bridging (L2 switching) rather than routing, which is the default, all normal bridge processing is performed for an inbound packet, which is then associated with a VLAN. Its MAC Destination Address (MAC DA) and VLAN ID are used to search the MAC address table. If routing is enabled for the VLAN, and the MAC DA of an inbound unicast packet is that of the internal router interface, the packet is routed. An inbound multicast packet is forwarded to all ports in the VLAN, plus the internal bridge-router interface, if it was received on a routed VLAN. Since a port can be configured to belong to more than one VLAN, VLAN routing might be enabled for all of the VLANs on the port or for only some of the VLANs on the port. VLAN Routing can be used to allow more than one physical port to reside on the same subnet. It could also be used when a VLAN spans multiple physical networks, or when additional segmentation or security is required. What Are Loopback Interfaces? A loopback interface is a logical interface that is always up and, because it cannot go down, allows the switch to have a stable IP address that other network devices and protocols can use to reach the switch. The loopback can provide the source address for sent packets. NOTE: In this context, loopback interfaces should not be confused with the loopback IP address, usually 127.0.0.1, assigned to a host for handling self-routed packets. The loopback interface does not behave like a network switching port. Specifically, there are no neighbors on a loopback interface; it is a pseudodevice for assigning local addresses so that the other layer 3 devices can communicate with the switch by using the loopback IP address. The loopback interface is always up and can receive traffic from any of the existing active interfaces. Thus, given reachability from a remote client, the address of the loopback can be used to communicate with the switch through various services such as Telnet and SSH. In this way, the IP address on a loopback behaves identically to any of the local addresses of the VLAN routing interfaces in terms of the processing of incoming packets. 844 Configuring Routing Interfaces What Are Tunnel Interfaces? Tunnels are a mechanism for transporting a packet across a network so that it can be evaluated at a remote location or tunnel endpoint. The tunnel, effectively, hides the packet from the network used to transport the packet to the endpoint. This allows for the transmission of packets that the transport network cannot process directly, such as in one of the following cases: • The packet protocol is not supported. • The packet is in an incompatible addressing space. • The packet is encrypted. PowerConnect 7000 Series switches support tunnels to encapsulate IPv6 traffic in IPv4 tunnels to provide functionality to facilitate the transition of IPv4 networks to IPv6 networks. The switch supports two types of tunnels: configured (6-in-4) and automatic (6-to-4). Configured tunnels have an explicit configured endpoint and are considered to be point-to-point interfaces. Automatic tunnels determine the endpoint of the tunnel from the destination address of packets routed into the tunnel. These tunnels correspond to Non-Broadcast Multi-Access (NBMA) interfaces. A configured tunnel interface has a single tunnel associated with it, while an automatic tunnel interface has an infinite number of tunnels (limited only by the address encoding scheme). Because tunnels are used as logical interfaces, you can define static routes that reference the tunnels. Additionally, dynamic routing can be configured to use the tunnels. Configuring Routing Interfaces 845 Why Are Routing Interfaces Needed? The routing interfaces this chapter describes have very different applications and uses, as this section describes. If you use the switch as a layer 2 device that handles switching only, routing interface configuration is not required. When the switch is used as a layer 2 device, it typically connects to an external layer 3 device that handles the routing functions. VLAN Routing VLAN routing is required when the switch is used as a layer 3 device. VLAN routing must be configured to allow the switch to forward IP traffic between subnets and allow hosts in different networks to communicate. In Figure 30-1 the PowerConnect switch is configured as an L3 device and performs the routing functions for hosts connected to the L2 switches. For Host A to communicate with Host B, no routing is necessary. These hosts are in the same VLAN. However, for Host A in VLAN 10 to communicate with Host C in VLAN 20, the PowerConnect switch must perform inter-VLAN routing. Figure 30-1. Inter-VLAN Routing PowerConnect Switch L2 Switch L2 Switch ` ` Host A Host B VLAN 10 846 Configuring Routing Interfaces ` Host C VLAN 20 Loopback Interfaces When packets are sent to the loopback IP address, the network should be able to deliver the packets as long as any physical interface on the switch is up. There are many cases where you need to send traffic to a switch, such as in switch management. The loopback interface IP address is a good choice for communicating with the switch in these cases because the loopback interface cannot go down when the switch is powered on and operational. Tunnel Interface Tunnels can be used in networks that support both IPv6 and IPv4. The tunnel allows non-contiguous IPv6 networks to be connected over an IPv4 infrastructure. Configuring Routing Interfaces 847 Default Routing Interface Values By default, no routing interfaces are configured. When you create a VLAN, no IP address is configured, and DHCP is disabled. After you configure an IP address on a VLAN or loopback interface, routing is automatically enabled on the VLAN interface, and the interface has the default configuration shown in Table 30-1. Most interface configuration parameters are not applicable to loopback interfaces, so you cannot change the default values. However, when you create a loopback interface, the default values are similar to those of VLAN routing interfaces, as Table 30-1 shows. Table 30-1. VLAN Routing Interface and Loopback Interface Defaults Parameter Default Value Forward Net Directed Broadcasts Disabled Encapsulation Type Ethernet (N/A for loopbacks) Proxy Arp Enabled Local Proxy Arp Disabled IP MTU 1500 Bandwidth Not configured. Destination Unreachables Enabled ICMP Redirects Enabled When you create a tunnel, it has the default values shown in Table 30-2 Table 30-2. Tunnel Interface Defaults Parameter Default Value Tunnel mode 6-in-4 configured Link Local Only Mode Disabled Source address None Destination address 0.0.0.0 848 Configuring Routing Interfaces Configuring Routing Interfaces (Web) This section provides information about the OpenManage Switch Administrator pages for configuring and monitoring VLAN routing interfaces, loopback interfaces, and tunnels on a PowerConnect 7000 Series switch. For details about the fields on a page, click at the top of the page. IP Interface Configuration Use the IP Interface Configuration page to update IP interface data for this switch. The IP interface configuration includes the ability to configure the bandwidth, Destination Unreachable messages, and ICMP Redirect messages. To display the page, click Routing → IP → IP Interface Configuration in the navigation panel. Figure 30-2. IP Interface Configuration Configuring Routing Interfaces 849 DHCP Lease Parameters Use the DHCP Lease Parameters page to view information about the network information automatically assigned to an interface by the DHCP server. To display the page, click Routing → IP → DHCP Lease Parameters in the navigation panel. Figure 30-3. DHCP Lease Parameters VLAN Routing Summary Use the VLAN Routing Summary page to view summary information about VLAN routing interfaces configured on the switch. To display the page, click Routing → VLAN Routing → Summary in the navigation panel. 850 Configuring Routing Interfaces Figure 30-4. VLAN Routing Summary Tunnel Configuration Use the Tunnels Configuration page to create, configure, or delete a tunnel. To display the page, click Routing → Tunnels → Configuration in the navigation panel. Figure 30-5. Tunnel Configuration Configuring Routing Interfaces 851 Tunnels Summary Use the Tunnels Summary page to display a summary of configured tunnels. To display the page, click Routing → Tunnels → Summary in the navigation panel. Figure 30-6. Tunnels Summary 852 Configuring Routing Interfaces Loopbacks Configuration Use the Loopbacks Configuration page to create, configure, or remove loopback interfaces. You can also set up or delete a secondary address for a loopback. To display the page, click Routing → Loopbacks → Loopbacks Configuration in the navigation panel. Figure 30-7. Loopback Configuration Configuring Routing Interfaces 853 Loopbacks Summary Use the Loopbacks Summary page to display a summary of configured loopback interfaces on the switch. To display the page, click Routing → Loopbacks → Loopbacks Summary in the navigation panel. Figure 30-8. Loopbacks Summary 854 Configuring Routing Interfaces Configuring Routing Interfaces (CLI) This section provides information about the commands you use to configure VLAN routing interfaces, loopbacks, and tunnels on the switch. For more information about the commands, see the PowerConnect 7000 Series CLI Reference Guide at support.dell.com/manuals. Configuring VLAN Routing Interfaces (IPv4) Beginning in Privileged EXEC mode, use the following commands to configure a VLAN as a routing interface and set the IP configuration parameters. Command Purpose configure Enter Global Configuration mode. interface vlan vlan-id Enter Interface Configuration mode for the specified VLAN. ip address {dhcp | none |ip_address subnet_mask [secondary]} Configure the IP address. Use the dhcp keyword to enable the DHCP client and obtain an IP address from a network DHCP server. Use none to release the address obtained from the DHCP server. Use ip_address and subnet_mask to assign a static IP address. If you configure a static address, you can use the secondary keyword to specify that the address is a secondary IP address. ip netdirbcast Enable the forwarding of network-directed broadcasts. encapsulation {ethernet | Configure the link-layer encapsulation type for the snap} packet. Routed frames are always ethernet encapsulated when a frame is routed to a VLAN. ip proxy-arp Enable proxy ARP on the interface. Without proxy ARP, the switch responds to an ARP request only if the target IP address is an address configured on the interface where the ARP request arrived. This command is not available in interface range mode. Configuring Routing Interfaces 855 Command Purpose ip local-proxy-arp Enable local proxy ARP on the interface to allow the switch to respond to ARP requests for hosts on the same subnet as the ARP source. ip mtu size Set the IP Maximum Transmission Unit (MTU) on a routing interface. The IP MTU is the size of the largest IP packet that can be transmitted on the interface without fragmentation. The range is 68–9198 bytes. bandwidth size Set the configured bandwidth on this interface to communicate the speed of the interface to higher level protocols. OSPF uses the bandwidth value to compute link cost. The range is 1–10000000. ip unreachables Allow the switch to send ICMP Destination Unreachable messages in response to packets received on the interface. ip redirects Allow the switch to send ICMP Redirect messages in response to packets received on the interface. exit Exit to Global Config mode. ip_address ip default-gateway Configure the default gateway. All switch interfaces use the same default gateway. exit Exit to Privileged EXEC mode. show dhcp lease [interface View information about the DHCP leases acquired for all interfaces or for the specified interface. interface] For a VLAN, the interface_string parameter is vlan followed by the VLAN ID, with no space, for example vlan10. show ip interface vlan vlan- View the IP interface configuration information for the specified routing VLAN. id 856 Configuring Routing Interfaces Configuring Loopback Interfaces Beginning in Privileged EXEC mode, use the following commands to configure a loopback interface. Command Purpose configure Enter Global Configuration mode. interface loopback Create the loopback interface and enter Interface Configuration mode for the specified loopback interface. ip address ip_address subnet_mask [secondary] Configure a static IP address and subnet mask. Use the secondary keyword to specify that the address is a secondary IP address. CTRL + Z Exit to Privileged EXEC mode. loopback-id show ip interface loopback View interface configuration information for the specified loopback interface. loopback-id Configuring Routing Interfaces 857 Configuring Tunnels Beginning in Privileged EXEC mode, use the following commands to configure a loopback interface. NOTE: For information about configuring the IPv6 interface characteristics for a tunnel, see "Configuring IPv6 Routing" on page 1057. Command Purpose configure Enter Global Configuration mode. interface tunnel tunnel-id Create the tunnel interface and enter Interface Configuration mode for the specified tunnel. tunnel mode ipv6ip [6to4] Specify the mode of the tunnel. If you use the 6to4 keyword, the tunnel is an automatic tunnel. If you omit the keyword, the tunnel is a point-to-point (configured) tunnel. ipv6 enable Enable IPv6 on this interface using the Link Local address. tunnel source {ipv4addr | vlan vlan-id} Specify the source transport address of the tunnel, either, which can be an IPv4 address or a VLAN routing interface. ipv4addr tunnel destination Specify the destination transport IPv4 address of the tunnel. CTRL + Z Exit to Privileged EXEC mode. show interfaces tunnel [tunnel-id] View configuration information for all tunnels or for the specified tunnel. 858 Configuring Routing Interfaces 31 Configuring DHCP Server Settings This chapter describes how to configure the switch to dynamically assign network information to hosts by using the Dynamic Host Configuration Protocol (DHCP). The topics covered in this chapter include: • DHCP Overview • Default DHCP Server Values • Configuring the DHCP Server (Web) • Configuring the DHCP Server (CLI) • DHCP Server Configuration Examples DHCP Overview DHCP is generally used between clients and servers for the purpose of assigning IP addresses, gateways, and other network settings such as DNS and SNTP server information. How Does DHCP Work? When a host connects to the network, the host’s DHCP client broadcasts a message requesting information from any DHCP server that receives the broadcast. One or more DHCP servers respond to the request. The response includes the requested information, such as the IP address, subnet mask, and default gateway IP address. The client accepts an offer from one of the servers, and the server sends an acknowledgment to the client to confirm the transaction. Configuring DHCP Server Settings 859 Figure 31-1. Message Exchange Between DHCP Client and Server DH C PD ISC O V ER (broadcast) DH C PO FFE R (unicast) ` DH C PR EQ U ES T (broadcast) D HC PA CK (unicast) DHCP Client DHCP Server (PowerConnect Switch) The DHCP server maintains one or more set of IP addresses the and other configuration information available, by request, to DHCP clients. Each set of information is known as an address pool. After a client leases an IP address from the DHCP server, the server adds an entry to its database. The entry is called a binding. What are DHCP Options? DHCP options are collections of data with type codes that indicate how the options should be used. Options can specify information that is required for the DHCP protocol, IP stack configuration parameters for the client, information allowing the client to rendezvous with DHCP servers, and so on. When a client broadcasts a request for information, the request includes the option codes that correspond to the information the client wants the DHCP server to supply. The Web pages and CLI commands to configure DHCP server settings include many predefined options for the information that is most commonly requested by DHCP clients. For example, DHCP client discover requests typically include options for the IP address (option 50), subnet mask (option 1), default gateway (option 3), and DNS server (option 6). These options are predefined. For options that are not predefined, you can enter the option code and specify the data type along with the data that the switch should include in DHCP offers. RFC2132 specifies many of the DHCP options. Additional options are described in later RFCs. 860 Configuring DHCP Server Settings What Additional DHCP Features Does the Switch Support? The switch software includes a DHCP client that can request network information from a DHCP server on the network during the initial system configuration process. For information about enabling the DHCP client, see "Setting the IP Address and Other Basic Network Information" on page 121. If the switch is functioning as a Layer 3 device, the Layer 3 DHCP Relay Agent can relay DHCP messages between DHCP clients and DHCP servers that are located in different IP subnets. The DHCP Layer 2 Relay feature permits Layer 3 Relay agent functionality in Layer 2 switched networks. The switch supports L2 DHCP relay configuration on individual ports, link aggregation groups (LAGs) and VLANs. For information about Layer 2 and Layer 3 DHCP Relay, see "Configuring L2 and L3 Relay Features" on page 907. DHCP Snooping is a security feature that monitors DHCP messages between a DHCP client and DHCP server. It filters harmful DHCP messages and builds a bindings database of (MAC address, IP address, VLAN ID, port) tuples that are specified as authorized. DHCP snooping can be enabled globally and on specific VLANs. For information about DHCP Snooping, see "Snooping and Inspecting Traffic" on page 781. Default DHCP Server Values By default, the DHCP server is disabled, and no address pools are configured. You must create at least one address pool and enable the DHCP server to allow the switch to dynamically assign network information to hosts with DHCP clients that broadcast requests. The DHCP server can lease a maximum of 256 addresses. Configuring DHCP Server Settings 861 Configuring the DHCP Server (Web) This section provides information about the OpenManage Switch Administrator pages for configuring and monitoring the DHCP server on a PowerConnect 7000 Series switch. For details about the fields on a page, click at the top of the page. DHCP Server Network Properties Use the Network Properties page to define global DHCP server settings and to configure addresses that are not included in any address pools. To display the Network Properties page, click Routing → IP → DHCP Server → Network Properties in the navigation panel. Figure 31-2. DHCP Server Network Properties 862 Configuring DHCP Server Settings Adding Excluded Addresses To exclude an address: 1 Open the Network Properties page. 2 Click Add Excluded Addresses to display the Add Excluded Addresses page. 3 In the From field, enter the first IP address to exclude from any configured address pool. 4 If the address in the From field is the only address to exclude, or if the excluded addresses are non-contiguous, leave the To field as the default value of 0.0.0.0. Otherwise, enter the last IP address to excluded from a contiguous range of IP addresses. In Figure 31-3, the From field contains the IP address 192.168.2.1, and the To field contains the IP address 192.168.2.5. This means that the following IP addresses are not available for lease: • 192.168.2.1 • 192.168.2.2 • 192.168.2.3 • 192.168.2.4 • 192.168.2.5 Figure 31-3. Add Excluded Addresses 5 Click Apply. Configuring DHCP Server Settings 863 Deleting Excluded Addresses To remove an excluded address: 1 Open the Network Properties page. 2 Click Delete Excluded Addresses to display the Delete Excluded Addresses page. 3 Select the check box next to the address or address range to delete. Figure 31-4. Delete Excluded Addresses 4 Click Apply. Address Pool Use the Address Pool page to create the pools of IP addresses and other network information that can be assigned by the server. To display the Address Pool page, click Routing → IP → DHCP Server → Address Pool in the navigation panel. 864 Configuring DHCP Server Settings Figure 31-5. Address Pool Adding a Network Pool To create and configure a network pool: 1 Open the Address Pool page. 2 Click Add Network Pool to display the Add Network Pool page. 3 Assign a name to the pool and complete the desired fields. In Figure 31-6, the network pool name is Engineering, and the address pool contains all IP addresses in the 192.168.5.0 subnet, which means a client that receives an address from the DHCP server might lease an address in the range of 192.168.5.1 to 192.168.5.254. Configuring DHCP Server Settings 865 Figure 31-6. Add Network Pool The Engineering pool also configures clients to use 192.168.5.1 as the default gateway IP address and 192.168.1.5 and 192.168.2.5 as the primary and secondary DNS servers. NOTE: The IP address 192.168.5.1 should be added to the global list of excluded addresses so that it is not leased to a client. 4 Click Apply. Adding a Static Pool To create and configure a static pool of IP addresses: 1 Open the Address Pool page. 2 Click Add Static Pool to display the Add Static Pool page. 3 Assign a name to the pool and complete the desired fields. 866 Configuring DHCP Server Settings In Figure 31-7, the Static pool name is Lab, and the name of the client in the pool is LabHost1. The client’s MAC address is mapped to the IP address 192.168.11.54, the default gateway is 192.168.11.1, and the DNS servers the client will use have IP addresses of 192.168.5.100 and 192.168.2.5. Figure 31-7. Add Static Pool 4 Click Apply. Configuring DHCP Server Settings 867 Address Pool Options Use the Address Pool Options page to view manually configured options. You can define options when you create an address pool, or you can add options to an existing address pool. To display the Address Pool Options page, click Routing → IP → DHCP Server → Address Pool Options in the navigation panel. Figure 31-8. Address Pool Options Defining DHCP Options To configure DHCP options: 1 Open the Address Pool page. 2 Select the Add Options check box. 3 Select the check box that corresponds to the value type (ASCII, Hexadecimal, or IP address). 4 Specify the value(s) in the corresponding field. Figure 31-9 shows an example of adding the SMTP server IP address. The option code for the SMTP server is 69, and the IP address of the SMTP server is 192.168.10.15. 868 Configuring DHCP Server Settings Figure 31-9. Add DHCP Option 5 Click Apply. 6 To verify that the option has been added to the address pool, open the Address Pool Options page. Configuring DHCP Server Settings 869 Figure 31-10. View Address Pool Options DHCP Bindings Use the DHCP Bindings page to view information about the clients that have leased IP addresses from the DHCP server. To display the DHCP Bindings page, click Routing → IP → DHCP Server → DHCP Bindings in the navigation panel. Figure 31-11. 870 DHCP Bindings Configuring DHCP Server Settings DHCP Server Reset Configuration Use the Reset Configuration page to clear the client bindings for one or more clients. You can also reset bindings for clients that have leased an IP address that is already in use on the network. To display the Reset Configuration page, click Routing → IP → DHCP Server → Reset Configuration in the navigation panel. Figure 31-12. Reset DHCP Bindings Configuring DHCP Server Settings 871 DHCP Server Conflicts Information Use the Conflicts Information page to view information about clients that have leased an IP address that is already in use on the network. To display the Conflicts Information page, click Routing → IP → DHCP Server → Conflicts Information in the navigation panel. Figure 31-13. 872 DHCP Server Conflicts Information Configuring DHCP Server Settings DHCP Server Statistics Use the Server Statistics page to view general DHCP server statistics, messages received from DHCP clients, and messages sent to DHCP clients. To display the Server Statistics page, click Routing → IP → DHCP Server → Server Statistics in the navigation panel. Figure 31-14. DHCP Server Statistics Configuring DHCP Server Settings 873 Configuring the DHCP Server (CLI) This section provides information about the commands you use to configure and monitor the DHCP server and address pools. For more information about the commands, see the PowerConnect 7000 Series CLI Reference Guide at support.dell.com/manuals. Configuring Global DHCP Server Settings Beginning in Privileged EXEC mode, use the following commands to configure settings for the DHCP server. Command Purpose configure Enter Global Configuration mode. service dhcp Enable the DHCP server. ip dhcp ping packets Specify the number, in a range from 2-10, of packets a DHCP server sends to a pool address as part of a ping operation. ip dhcp conflict logging Enable conflict logging on DHCP server ip dhcp bootp automatic Enable the allocation of the addresses to the BootP client. ip dhcp excludedaddress lowaddress [highaddress] Specify the IP addresses that a DHCP server should not assign to DHCP clients. You can specify a single IP address, or you can specify a contiguous range by using both the low-address and high-address variables. exit Exit to Privileged EXEC mode. show ip dhcp global configuration Verify the global DHCP server configuration. 874 Configuring DHCP Server Settings Configuring a Dynamic Address Pool Beginning in Privileged EXEC mode, use the following commands to create an address pool with network information that is dynamically assigned to hosts with DHCP clients that request the information. Command Purpose configure Enter Global Configuration mode. ip dhcp pool name Create a DHCP address pool and enters DHCP pool configuration mode. network network-ip [mask | prefixlength] Configure the subnet number and mask for a DHCP address pool. Clients requesting an IP address can be assigned any non-excluded IP address within this network. lease [duration] | infinite}] Specify the duration of the lease for an IP address that is assigned from a DHCP server to a DHCP client. • duration— Days the lease is valid. You can optionally specify the hours and minutes after specifying the days. • infinite — 60 day lease default-router address1 [address2....address8] Specify the list of default gateway IP addresses to be assigned to the DHCP client. dns-server address1 [address2....address8] Specify the list of DNS server IP addresses to be assigned to the DHCP client. domain-name domain Specify the domain name for a DHCP client. option code {ascii string Manually configure DHCP options. | hex string1 [string2...string8] | ip address1 [address2...address8]} CTRL + Z Exit to Privileged EXEC mode. show ip dhcp pool configuration {name | all} View the settings for the specified address pool or for all configured address pools. Configuring DHCP Server Settings 875 Configuring a Static Address Pool Beginning in Privileged EXEC mode, use the following commands to create a static address pool and specify the network information for the pool. The network information configured in the static address pool is assigned only to the host with the hardware address or client identifier that matches the information configured in the static pool. Command Purpose configure Enter Global Configuration mode. ip dhcp pool name Create a DHCP address pool and enters DHCP pool configuration mode. client-name name Specify the DHCP client name. hardware-address mac [type] Specify the hardware address of the client in the static pool. • mac—MAC address of the hardware platform of the client consisting of 6 bytes in dotted hexadecimal format. • type — Indicates the protocol of the hardware platform. It is 1 for Ethernet and 6 for IEEE 802. client-identifier uniqueidentifier Specify the unique identifier for a DHCP client. The unique-identifier is a valid notation in hexadecimal format. In some systems, such as Microsoft DHCP clients, the client identifier is required instead of hardware addresses. The unique-identifier is a concatenation of the media type and the MAC address. For example, the Microsoft client identifier for Ethernet address c819.2488.f177 is 01c8.1924.88f1.77 where 01 represents the Ethernet media type. host address [mask | prefix-length] Specify the IP address and (optionally) network mask for a manual binding to a DHCP client. lease [duration] | infinite}] Specify the duration of the lease for an IP address that is assigned from a DHCP server to a DHCP client. • duration— Days the lease is valid. You can optionally specify the hours and minutes after specifying the days. • infinite — 60 day lease 876 Configuring DHCP Server Settings Command Purpose default-router address1 [address2....address8] Specify the list of default gateway IP addresses to be assigned to the DHCP client. dns-server address1 [address2....address8] Specify the list of DNS server IP addresses to be assigned to the DHCP client. domain-name domain Specify the domain name for a DHCP client. option code {ascii string Manually configure DHCP options. | hex string1 [string2...string8] | ip address1 [address2...address8]} CTRL + Z Exit to Privileged EXEC mode. show ip dhcp pool configuration {name | all} View the settings for the specified address pool or for all configured address pools. Monitoring DHCP Server Information Beginning in Privileged EXEC mode, use the following commands to view bindings, conflicts, and statistics, and to clear the information. Command Purpose show ip dhcp binding [address] View the current binding information in the DHCP server database. Specify the IP address to view a specific binding. clear ip dhcp binding {address | *} Delete an automatic address binding from the DHCP server database. Use * to clear all bindings. show ip dhcp conflict [address] View the current binding conflicts in the DHCP server database. Specify the IP address to view a specific conflict. clear ip dhcp conflict {address | *} Clear an address conflict from the DHCP Server database. Use * to clear all conflicts. show ip dhcp server statistics View DHCP server statistics. clear ip dhcp server statistics Reset all DHCP server statistics to zero. Configuring DHCP Server Settings 877 DHCP Server Configuration Examples This section contains the following examples: • Configuring a Dynamic Address Pool • Configuring a Static Address Pool Configuring a Dynamic Address Pool The commands in this example create an address pool that dynamically assigns network information to hosts with DHCP clients that broadcast DHCP messages. The hosts are assigned an IP address from the 192.168.5.0 network. The IP addresses 192.168.5.1–192.168.5.20, and 192.168.5.100 are excluded from the address pool. To configure the switch: 1 Create an address pool named “Engineering” and enter into DHCP pool configuration mode for the pool. console#configure console(config)#ip dhcp pool Engineering 2 Specify the IP addresses that are available in the pool. console(config-dhcp-pool)#network 192.168.5.0 255.255.255.0 3 Specify the IP address to use as the default gateway. console(config-dhcp-pool)#default-router 192.168.5.1 4 Specify the primary and secondary DNS servers the hosts will use. console(config-dhcp-pool)#dns-server 192.168.5.10 console(config-dhcp-pool)#dns-server 192.168.5.11 5 Specify the domain name to be assigned to clients that lease an address from this pool. console(config-dhcp-pool)#domain-name engineering.dell.com console(config-dhcp-pool)#exit 878 Configuring DHCP Server Settings 6 In Global Configuration mode, add the addresses to exclude from the pool. Clients will not be assigned these IP addresses. console(config)#ip dhcp excluded-address 192.168.5.1 192.168.5.20 console(config)#ip dhcp excluded-address 192.168.5.100 7 Enable the DHCP server on the switch. console(config)#service dhcp console(config)#exit 8 View DHCP server settings. console#show ip dhcp global configuration Service DHCP...................Enable Number of Ping Packets.........2 Excluded Address...............192.168.2.1 to 192.168.2.20 1.2.2.2 to 1.5.5.5 192.168.5.1 to 192.168.5.20 192.168.5.100 to 192.168.5.100 Conflict Logging...............Enable Bootp Automatic................Disable 9 View information about all configured address pools. console#show ip dhcp pool configuration all Pool: Engineering Pool Type.......................... Network............................ Lease Time......................... DNS Servers........................ Default Routers.................... Domain Name........................ Network 192.168.5.0 255.255.255.0 1 days 0 hrs 0 mins 192.168.5.11 192.168.5.1 engineering.dell.com Configuring DHCP Server Settings 879 Configuring a Static Address Pool The commands in this example create an address pool that assigns the address 192.168.2.10 to the host with a MAC address of 00:1C:23:55:E9:F3. When this hosts sends a DHCP message requesting network information, the switch will offer the information configured in this example, which includes a custom DHCP option to assign the SMTP server IP address. To configure the switch: 1 Create an address pool named “Tyler PC” and enter into DHCP pool configuration mode for the pool. console#configure console(config)#ip dhcp pool "Tyler PC" 2 Specify the IP addresses that are available in the pool. console(config-dhcp-pool)#hardware-address 00:1C:23:55:E9:F3 3 Specify the IP address and subnet mask to assign to the client. console(config-dhcp-pool)#host 192.168.2.10 255.255.255.0 4 Specify the IP address to use as the default gateway. console(config-dhcp-pool)#default-router 192.168.2.1 5 Specify the primary and secondary DNS servers the hosts will use. console(config-dhcp-pool)#dns-server 192.168.2.100 console(config-dhcp-pool)#dns-server 192.168.5.101 6 Specify the domain name to be assigned to clients that lease an address from this pool. console(config-dhcp-pool)#domain-name executive.dell.com 7 Specify the option that configures the SMTP server IP address to the host. console(config-dhcp-pool)#option 69 ip 192.168.1.33 console(config-dhcp-pool)#exit 880 Configuring DHCP Server Settings 8 View information about the static address pool. console#show ip dhcp pool configuration "Tyler PC" Pool: Tyler PC Pool Type..........................Static Client Name........................TylerPC Hardware Address.................. 00:1c:23:55:e9:f3 Hardware Address Type..............ethernet Host.............................. 192.168.2.10 255.255.255.0 Lease Time........................ 1 days 0 hrs 0 mins DNS Servers....................... 192.168.2.101 Default Routers................... 192.168.2.1 Domain Name....................... executive.dell.com Option............................ 69 ip 192.168.1.33 Configuring DHCP Server Settings 881 882 Configuring DHCP Server Settings Configuring IP Routing 32 This chapter describes how to configure routing on the switch, including global routing settings, Address Resolution Protocol (ARP), router discovery, and static routes. The topics covered in this chapter include: • IP Routing Overview • Default IP Routing Values • Configuring IP Routing Features (Web) • Configuring IP Routing Features (CLI) • IP Routing Configuration Example IP Routing Overview The PowerConnect 7000 Series switches are multilayer switches that support static and dynamic routing. Table 32-1 describes some of the general routing features that you can configure on the switch. Table 32-1. IP Routing Features Feature Description ICMP message control You can configure the type of ICMP messages that the switch responds to as well as the rate limit and burst size. Default gateway The switch supports a single default gateway. A manually configured default gateway is more preferable than a default gateway learned from a DHCP server. ARP table The switch maintains an ARP table that maps an IP address to a MAC address. You can create static ARP entries in the table and manage various ARP table settings such as the aging time of dynamically-learned entries. Configuring IP Routing 883 Table 32-1. IP Routing Features (Continued) Feature Description ICMP Router Discovery Protocol (IRDP) Hosts can use IRDP to identify operational routers on the subnet. Routers periodically advertise their IP addresses. Hosts listen for these advertisements and discover the IP addresses of neighboring routers. Routing table entries You can configure the following route types in the routing table: • Default: The default route is the route the switch will use to send a packet if the routing table does not contain a longer matching prefix for the packet's destination. • Static: A static route is a route that you manually add to the routing table. • Static Reject: Packets that match a reject route are discarded instead of forwarded. The router may send an ICMP Destination Unreachable message. Route preferences 884 Configuring IP Routing The common routing table collects static, local, and dynamic (routing protocol) routes. When there is more than one route to the same destination prefix, the routing table selects the route with the best (lowest) route preference. Default IP Routing Values Table 32-2 shows the default values for the IP routing features this chapter describes. Table 32-2. IP Routing Defaults Parameter Default Value Default Time to Live 64 Routing Mode Disabled globally and on each interface ICMP Echo Replies Enabled ICMP Redirects Enabled ICMP Rate Limit Interval 1000 milliseconds ICMP Rate Limit Burst Size 100 Maximum Next Hops 4 Global Default Gateway None Dynamic ARP Entry Age Time 1200 seconds Automatic Renewal of Dynamic ARP Entries Disabled ARP Response Timeout 1 second ARP Retries 4 Maximum Static ARP Entries 128 IRDP Advertise Mode Disabled IRDP Advertise Address 224.0.0.1 IRDP Maximum Advertise Interval 600 seconds IRDP Minimum Advertise Interval 450 seconds IRDP Advertise Lifetime 1800 seconds IRDP Preference Level 0 Configuring IP Routing 885 Table 32-2. IP Routing Defaults (Continued) Parameter Default Value Route Preference Values Preference values are as follows: • Local—0 • Static—1 • OSPF Intra—110 • OSPF Inter—110 • OSPF External—110 • RIP—120 886 Configuring IP Routing Configuring IP Routing Features (Web) This section provides information about the OpenManage Switch Administrator pages for configuring and monitoring IPv4 routing features on a PowerConnect 7000 Series switch. For details about the fields on a page, click at the top of the page. IP Configuration Use the Configuration page to configure routing parameters for the switch as opposed to an interface. The IP configuration settings allow you to enable or disable the generation of various types of ICMP messages. To display the page, click Routing → IP → Configuration in the navigation panel. Figure 32-1. IP Configuration Configuring IP Routing 887 IP Statistics The IP statistics reported on the Statistics page are as specified in RFC 1213. To display the page, click Routing → IP → Statistics in the navigation panel. Figure 32-2. IP Statistics 888 Configuring IP Routing ARP Create Use the Create page to add a static ARP entry to the Address Resolution Protocol table. To display the page, click Routing → ARP → Create in the navigation panel. Figure 32-3. ARP Create Configuring IP Routing 889 ARP Table Configuration Use the Table Configuration page to change the configuration parameters for the Address Resolution Protocol Table. You can also use this screen to display the contents of the table. To display the page, click Routing → ARP → Table Configuration in the navigation panel. Figure 32-4. ARP Table Configuration 890 Configuring IP Routing Router Discovery Configuration Use the Configuration page to enter or change router discovery parameters. To display the page, click Routing → Router Discovery → Configuration in the navigation panel. Figure 32-5. Router Discovery Configuration Configuring IP Routing 891 Router Discovery Status Use the Status page to display router discovery data for each interface. To display the page, click Routing → Router Discovery → Status in the navigation panel. Figure 32-6. Router Discovery Status 892 Configuring IP Routing Route Table Use the Route Table page to display the contents of the routing table. To display the page, click Routing → Router → Route Table in the navigation panel. Figure 32-7. Route Table Configuring IP Routing 893 Best Routes Table Use the Best Routes Table page to display the best routes from the routing table. To display the page, click Routing → Router → Best Routes Table in the navigation panel. Figure 32-8. Best Routes Table 894 Configuring IP Routing Route Entry Configuration Use the Route Entry Configuration page to add new and configure router routes. To display the page, click Routing → Router → Route Entry Configuration in the navigation panel. Figure 32-9. Route Entry Configuration Adding a Route and Configuring Route Preference To configure routing table entries: 1 Open the Route Entry Configuration page. 2 Click Router Route Entry Configuration. The screen refreshes and the Router Route Entry Configuration page displays. Configuring IP Routing 895 Figure 32-10. Router Route Entry and Preference Configuration 3 Next to Route Type, use the drop-down box to add a Default, Static, or Static Reject route. The fields to configure are different for each route type. • Default — Enter the default gateway address in the Next Hop IP Address field. • Static — Enter values for Network Address, Subnet Mask, Next Hop IP Address, and Preference. • Static Reject — Enter values for Network Address, Subnet Mask, and Preference. 4 Click Apply. The new route is added to the routing table. 896 Configuring IP Routing Configured Routes Use the Configured Routes page to display the routes that have been manually configured. NOTE: For a static reject route, the next hop interface value is Null0. Packets to the network address specified in static reject routes are intentionally dropped. To display the page, click Routing → Router → Configured Routes in the navigation panel. Figure 32-11. Configured Routes To remove a configured route, select the check box in the Remove column of the route to delete, and click Apply. Configuring IP Routing 897 Route Preferences Configuration Use the Route Preferences Configuration page to configure the default preference for each protocol (for example 60 for static routes). These values are arbitrary values that range from 1 to 255, and are independent of route metrics. Most routing protocols use a route metric to determine the shortest path known to the protocol, independent of any other protocol. To display the page, click Routing → Router → Route Preferences Configuration in the navigation panel. Figure 32-12. 898 Router Route Preferences Configuration Configuring IP Routing Configuring IP Routing Features (CLI) This section provides information about the commands you use to configure IPv4 routing on the switch. For more information about the commands, see the PowerConnect 7000 Series CLI Reference Guide at support.dell.com/manuals. Configuring Global IP Routing Settings Beginning in Privileged EXEC mode, use the following commands to configure various global IP routing settings for the switch. Command Purpose configure Enter global configuration mode. ip routing Globally enable IPv4 routing on the switch. ip icmp echo-reply Allow the switch to generate ICMP Echo Reply messages. ip icmp error-interval burst-interval [burstsize] Limit the rate at which IPv4 ICMP error messages are sent. • burst-interval — How often the token bucket is initialized (Range: 0–2147483647 milliseconds). • burst-size — The maximum number of messages that can be sent during a burst interval (Range: 1–200). ip redirects Allow the switch to generate ICMP Redirect messages. ip default-gateway ip- address Configure the global default gateway for the switch. The gateway configured here takes precedence over a default gateway assigned by a network DHCP server. exit Exit to Privileged EXEC mode. show ip brief View the global IP settings for the switch. Configuring IP Routing 899 Adding Static ARP Entries and Configuring ARP Table Settings Beginning in Privileged EXEC mode, use the following commands to configure static ARP entries in the ARP cache and to specify the settings for the ARP cache. Command Purpose configure Enter global configuration mode. arp ip-address hardware- Create a static ARP entry in the ARP table. address • ip-address — IP address of a device on a subnet attached to an existing routing interface. • hardware-address — A unicast MAC address for that device. arp timeout seconds Configure the ARP entry ageout time. arp resptime seconds Configure the ARP request response timeout. arp retries integer Configure the ARP count of maximum requests for retries. The range is 1–10. arp cachesize integer Configure the maximum number of entries in the ARP cache. arp dynamicrenew Allow the ARP component to automatically renew dynamic ARP entries when they age out. exit Exit to Privileged EXEC mode. show arp [brief] View the user-configured (static) ARP entries. The static entries display regardless of whether they are reachable over an interface. Use the brief keyword to view only the ARP table settings. clear arp-cache [gateway] Remove all dynamic ARP entries from the ARP cache. Include the keyword gateway to remove gateway entries as well. clear arp-cache management Remove all dynamic ARP entries from the ARP cache that were learned on the management interface. arp purge ip-address Remove the specified IP address from the ARP cache. This command removes dynamic and gateway ARP entries only. 900 Configuring IP Routing Configuring Router Discovery (IRDP) Beginning in Privileged EXEC mode, use the following commands to configure IRDP settings. Command Purpose configure Enter global configuration mode. interface interface Enter interface configuration mode for the specified VLAN routing interface. The interface variable includes the interface type (vlan) and number, for example vlan 100. ip irdp Enable IRDP on the interface. ip irdp address ip-address Configure the address that the interface uses to send the router discovery advertisements. The allowed addresses are 224.0.0.1 (all-hosts IP multicast address) or 255.255.255.255 (limited broadcast address) ip irdp holdtime seconds Configure the value of the holdtime field of the router advertisement sent from this interface. ip irdp maxadvertinterval Configure the maximum time allowed between sending router advertisements from the interface. seconds ip irdp minadvertinterval Configure the minimum time allowed between sending seconds router advertisements from the interface. ip irdp preference integer Configure the preference of the address as a default router address relative to other router addresses on the same subnet. exit Exit to Global Config mode. exit Exit to Privileged EXEC mode. show ip irdp [vlan vlan-id] View the router discovery information for all interfaces, or for a specified interface. Configuring IP Routing 901 Configuring Route Table Entries and Route Preferences Beginning in Privileged EXEC mode, use the following commands to configure IRDP settings. Command Purpose configure Enter global configuration mode. Configure the default route. ip route default nextHopRtr [preference ] • nextHopRtr — IP address of the next hop router. • preference — Specifies the preference value (administrative distance) of an individual static route. (Range: 1-255) ip route ip-addr {subnetmask | prefix length } {nextHopRtr | null} [preference ] Configure a static route. Use the keyword null instead of the next hop router IP address to configure a static reject route. • ip-address — IP address of destination interface. • subnet-mask — Subnet mask of destination interface. • prefix-length — Length of prefix. Must be preceded with a forward slash (/). (Range: 0-32 bits) • nextHopRtr — IP address of the next hop router. • null — Specifies that the route is a static reject route. • preference — Specifies the preference value (administrative distance) of an individual static route. (Range: 1-255) ip route distance integer Set the default distance (preference) for static routes. Lower route preference values are preferred when determining the best route. exit Exit to Privileged EXEC mode. 902 Configuring IP Routing Command Purpose show ip route [ip-address [mask | prefix-length] [longer-prefixes] | protocol] View the routing table. • ip-address — Specifies the network for which the route is to be displayed and displays the best matching bestroute for the address. • mask — Subnet mask of the IP address. • prefix-length — Length of prefix, in bits. Must be preceded with a forward slash (‘/’). (Range: 0-32 bits) • longer-prefixes — Indicates that the ip-address and subnet-mask pair becomes the prefix, and the command displays the routes to the addresses that match that prefix. • protocol — Specifies the protocol that installed the routes. (Range: connected, ospf, rip, static) show ip route configured View the configured routes, whether they are reachable or not. show ip route summary View summary information about the routing table. show ip protocols View the parameters and current state of the active routing protocols. show ip route preferences View detailed information about the route preferences. Configuring IP Routing 903 IP Routing Configuration Example In this example, the PowerConnect switches are L3 switches with VLAN routing interfaces. VLAN routing is configured on PowerConnect Switch A and PowerConnect Switch B. This allows the host in VLAN 10 to communicate with the server in VLAN 30. A static route to the VLAN 30 subnet is configured on Switch A. Additionally, a default route is configured on Switch A so that all traffic with an unknown destination is sent to the backbone router through port 24, which is a member of VLAN 50. A default route is configured on PowerConnect Switch B to use Switch A as the default gateway. The hosts use the IP address of the VLAN routing interface as their default gateway. This example assumes that all L2 VLAN information, such as VLAN creation and port membership, has been configured. Figure 32-13. 904 IP Routing Example Topology Configuring IP Routing Configuring PowerConnect Switch A To configure Switch A. 1 Enable routing on the switch. console#configure console(config)#ip routing 2 Assign an IP address to VLAN 10. This command also enables IP routing on the VLAN. console(config)#interface vlan 10 console(config-if-vlan10)#ip address 192.168.10.10 255.255.255.0 console(config-if-vlan10)#exit 3 Assign an IP address to VLAN 20. console#configure console(config)#interface vlan 20 console(config-if-vlan20)#ip address 192.168.20.20 255.255.255.0 console(config-if-vlan20)#exit 4 Assign an IP address to VLAN 50. console#configure console(config)#interface vlan 50 console(config-if-vlan50)#ip address 192.168.50.50 255.255.255.0 console(config-if-vlan50)#exit 5 Configure a static route to the network that VLAN 30 is in, using the IP address of the VLAN 20 interface on Switch B as the next hop address. console(config)#ip route 192.168.30.0 255.255.255.0 192.168.20.25 6 Configure the backbone router interface as the default gateway. console(config)#ip route default 192.168.50.2 Configuring IP Routing 905 Configuring PowerConnect Switch B To configure Switch B: 1 Enable routing on the switch. console#configure console(config)#ip routing 2 Assign an IP address to VLAN 20. This command also enables IP routing on the VLAN. console#configure console(config)#interface vlan 20 console(config-if-vlan20)#ip address 192.168.20.25 255.255.255.0 console(config-if-vlan20)#exit 3 Assign an IP address to VLAN 30. This command also enables IP routing on the VLAN. console#configure console(config)#interface vlan 30 console(config-if-vlan30)#ip address 192.168.30.30 255.255.255.0 console(config-if-vlan30)#exit 4 Configure the VLAN 20 routing interface on Switch A as the default gateway so that any traffic with an unknown destination is sent to Switch A for forwarding. console(config)#ip route default 192.168.20.20 906 Configuring IP Routing Configuring L2 and L3 Relay Features 33 This chapter describes how to configure the L2 DHCP Relay, L3 DHCP Relay, and IP Helper features on PowerConnect 7000 Series switches. The topics covered in this chapter include: • L2 and L3 Relay Overview • Default L2/L3 Relay Values • Configuring L2 and L3 Relay Features (Web) • Configuring L2 and L3 Relay Features (CLI) • Relay Agent Configuration Example L2 and L3 Relay Overview When a DHCP client and server are in the same IP subnet, they can directly connect to exchange IP address requests and replies. However, buying and maintaining a DHCP server on each subnet can be expensive and is often impractical. The relay features on the PowerConnect 7000 Series switches can help enable communication between DHCP clients and DHCP servers that reside in different subnets. Configuring L3 DHCP relay also enables the bootstrap protocol (BOOTP) relay. What Is L3 DHCP Relay? Network infrastructure devices can be used to relay packets between a DHCP client and server on different subnets. Such a device, an Layer 3 Relay agent, is often a router or L3 switch. The L3 relay agent must have an IP interface on the client subnets and, if it does not have an IP interface on the server’s subnet, it should be able to route traffic toward the server’s subnet. The PowerConnect DHCP Relay Agent enables DHCP clients and servers to exchange DHCP messages across different subnets. The relay agent receives the requests from the clients, and checks the valid hops and giaddr fields in Configuring L2 and L3 Relay Features 907 the DHCP request. If the number of hops is greater than the configured number, the agent discards the packet. If the giaddr field is zero, the agent must fill in this field with the IP address of the interface on which the request was received. The agent unicasts the valid packets to all configured DHCP servers. Each server responds with a unicast BOOTREPLY addressed to the relay agent closest to the client as indicated by giaddr field. Upon reception of the BOOTREPLY from the server, the agent forwards this reply as broadcast or unicast on the interface where the BOOTREQUEST arrived. This interface can be identified by the giaddr field or option 82. The PowerConnect 7000 Series switch DHCP component also supports DHCP relay agent options to identify the client interface. If configured, the relay agent inserts these options when forwarding the request to the server and removes them when sending the reply to the clients. If an interface has more than one IP address, the relay agent uses the primary IP address configured as its relay agent IP address. What Is L2 DHCP Relay? In Layer 2 switched networks, there may be one or more infrastructure devices (for example, a switch) between the client and the L3 Relay agent/DHCP server. In this instance, some of the client device information required by the L3 Relay agent may not be visible to it. In this case, an L2 Relay agent can be used to add the information that the L3 Relay Agent and DHCP server need to perform their roles in address and configuration and assignment. Before it relays DHCP requests from clients, the switch can add a Circuit ID and a Remote ID. These IDs provide information about the circuit and port number connected to the client. This information is added as suboptions in the DHCP Option 82 packets as defined in sections 3.1 and 3.2 of RFC3046. The switch removes this option from packets that it relays from L3 Relay agents/DHCP servers to clients. These sub-options may be used by the DHCP server to affect how it treats the client and also may be used by the relay agent to limit broadcast replies to the specific circuit or attachment point of the client. 908 Configuring L2 and L3 Relay Features Enabling L2 Relay on VLANs You can enable L2 DHCP relay on a particular VLAN. The VLAN is identified by a service VLAN ID (S-VID), which a service provider uses to identify a customer’s traffic while traversing the provider network to multiple remote sites. The switch uses the VLAN membership of the switch port client (the customer VLAN ID, or C-VID) to perform a lookup a corresponding S-VID. If the S-VID is enabled for DHCP Relay, then the packet can be forwarded. If the C-VID does not correspond to an S-VID that is enabled for DHCP Relay, then the switch will not relay the DHCP request packet. What Is the IP Helper Feature? The IP Helper feature provides the ability for a router to forward configured UDP broadcast packets to a particular IP address. This allows applications to reach servers on non-local subnets. This is possible even when the application is designed to assume a server is always on a local subnet or when the application uses broadcast packets to reach the server (with the limited broadcast address 255.255.255.255, or a network directed broadcast address). You can configure relay entries globally and on routing interfaces. Each relay entry maps an ingress interface and destination UDP port number to a single IPv4 address (the helper address). Multiple relay entries may be configured for the same interface and UDP port, in which case the relay agent relays matching packets to each server address. Interface configuration takes priority over global configuration. If the destination UDP port for a packet matches any entry on the ingress interface, the packet is handled according to the interface configuration. If the packet does not match any entry on the ingress interface, the packet is handled according to the global IP helper configuration. You can configure discard relay entries. Discard entries are used to discard packets received on a specific interface when those packets would otherwise be relayed according to a global relay entry. Discard relay entries may be configured on interfaces, but are not configured globally. Additionally, you can configure which UDP ports are forwarded. Certain UDP port numbers can be selected from the web interface or specified by name in the CLI, but you can also configure a relay entry with any UDP port number. You may configure relay entries that do not specify a destination UDP port. The relay agent assumes that these entries match packets with the UDP destination ports listed in Table 33-1 (the list of default ports). Configuring L2 and L3 Relay Features 909 Table 33-1. Default Ports - UDP Port Numbers Implied By Wildcard Protocol UDP Port Number IEN-116 Name Service 42 DNS 53 NetBIOS Name Server 137 NetBIOS Datagram Server 138 TACACS Server 49 Time Service 37 DHCP 67 Trivial File Transfer Protocol 69 The system limits the number of relay entries to four times the maximum number of routing interfaces (512 relay entries). There is no limit to the number of relay entries on an individual interface, and no limit to the number of servers for a given {interface, UDP port} pair. Certain configurable DHCP relay options do not apply to relay of other protocols. You may optionally set a maximum hop count or minimum wait time using the bootpdhcprelay maxhopcount and bootpdhcprelay minwaittime commands. The relay agent relays DHCP packets in both directions. It relays broadcast packets from the client to one or more DHCP servers, and relays packets to the client that the DHCP server unicasts back to the relay agent. For other protocols, the relay agent only relays broadcast packets from the client to the server. Packets from the server back to the client are assumed to be unicast directly to the client. Because there is no relay in the return direction for protocols other than DHCP, the relay agent retains the source IP address from the original client packet. The relay agent uses a local IP address as the source IP address of relayed DHCP client packets. When a switch receives a broadcast UDP packet on a routing interface, the relay agent verifies that the interface is configured to relay to the destination UDP port. If so, the relay agent unicasts the packet to the configured server IP addresses. Otherwise, the relay agent verifies that there is a global 910 Configuring L2 and L3 Relay Features configuration for the destination UDP port. If so, the relay agent unicasts the packet to the configured server IP addresses. Otherwise the packet is not relayed. NOTE: If the packet matches a discard relay entry on the ingress interface, the packet is not forwarded, regardless of the global configuration. The relay agent relays packets that meet only the following conditions: • The destination MAC address must be the all-ones broadcast address (FF:FF:FF:FF:FF:FF). • The destination IP address must be the limited broadcast address (255.255.255.255) or a directed broadcast address for the receive interface. • The IP time-to-live (TTL) must be greater than 1. • The protocol field in the IP header must be UDP (17). • The destination UDP port must match a configured relay entry. Configuring L2 and L3 Relay Features 911 Table 33-2 shows the most common protocols and their UDP port numbers and names that are relayed. Table 33-2. UDP Port Allocations UDP Port Number Acronym Application 7 Echo Echo 11 SysStat Active User 15 NetStat NetStat 17 Quote Quote of the day 19 CHARGEN Character Generator 20 FTP-data FTP Data 21 FTP FTP 37 Time Time 42 NAMESERVER Host Name Server 43 NICNAME Who is 53 DOMAIN Domain Name Server 69 TFTP Trivial File Transfer 111 SUNRPC Sun Microsystems Rpc 123 NTP Network Time 137 NetBiosNameService NT Server to Station Connections 138 NetBiosDatagramService NT Server to Station Connections 139 NetBios SessionServiceNT Server to Station Connections 161 SNMP Simple Network Management 162 SNMP-trap Simple Network Management Traps 513 who Unix Rwho Daemon 514 syslog System Log 525 timed Time Daemon 912 Configuring L2 and L3 Relay Features Default L2/L3 Relay Values By default L2 DHCP relay is disabled. L3 relay (UDP) is enabled, but no UDP destination ports or server addresses are defined on the switch or on any interfaces. Table 33-3. L2/L3 Relay Defaults Parameter Default Value L2 DHCP Relay Admin Mode Disabled globally and on all interfaces and VLANs Trust Mode Disabled on all interfaces Circuit ID Disabled on all VLANs Remote ID None configured L3 DHCP Relay UDP Relay Mode (IP Helper) Enabled Hop Count 4 Minimum Wait Time 0 seconds Circuit ID Option Mode Disabled Circuit ID Check Mode Enabled Information Option-Insert Disabled on all VLAN interfaces Information Check-Reply Enabled on all VLAN interfaces Configuring L2 and L3 Relay Features 913 Configuring L2 and L3 Relay Features (Web) This section provides information about the OpenManage Switch Administrator pages for configuring and monitoring L2 and L3 relay features on a PowerConnect 7000 Series switch. For details about the fields on a page, click at the top of the page. DHCP Relay Global Configuration Use this page to enable or disable the switch to act as a DHCP Relay agent. This functionality must also be enabled on each port you want this service to operate on (see "DHCP Relay Interface Configuration" on page 915). The switch can also be configured to relay requests only when the VLAN of the requesting client corresponds to a service provider’s VLAN ID that has been enabled with the L2 DHCP relay functionality (see "DHCP Relay VLAN Configuration" on page 918). To access this page, click Switching → DHCP Relay → Global Configuration in the navigation panel. Figure 33-1. DHCP Relay Global Configuration 914 Configuring L2 and L3 Relay Features DHCP Relay Interface Configuration Use this page to enable L2 DHCP relay on individual ports. NOTE: L2 DHCP relay must also be enabled globally on the switch. To access this page, click Switching → DHCP Relay → Interface Configuration in the navigation panel. Figure 33-2. DHCP Relay Interface Configuration To view a summary of the L2 DHCP relay configuration on all ports and LAGS, click Show All. Configuring L2 and L3 Relay Features 915 Figure 33-3. DHCP Relay Interface Summary 916 Configuring L2 and L3 Relay Features DHCP Relay Interface Statistics Use this page to display statistics on DHCP Relay requests received on a selected port. To access this page, click Switching → DHCP Relay → Interface Statistics in the navigation panel. Figure 33-4. DHCP Relay Interface Statistics Configuring L2 and L3 Relay Features 917 DHCP Relay VLAN Configuration Use this page to enable and configure DHCP Relay on specific VLANs. To access this page, click Switching → DHCP Relay → VLAN Configuration in the navigation panel. Figure 33-5. DHCP Relay VLAN Configuration To view a summary of the L2 DHCP relay configuration on all VLANs, click Show All. Figure 33-6. DHCP Relay VLAN Summary 918 Configuring L2 and L3 Relay Features DHCP Relay Agent Configuration Use the Configuration page to configure and display a DHCP relay agent. To display the page, click Routing → DHCP Relay Agent → Configuration in the navigation panel. Figure 33-7. DHCP Relay Agent Configuration Configuring L2 and L3 Relay Features 919 IP Helper Global Configuration Use the Global Configuration page to add, show, or delete UDP Relay and Helper IP configuration To display the page, click Routing → IP Helper → Global Configuration in the navigation panel. Figure 33-8. IP Helper Global Configuration Adding an IP Helper Entry To configure an IP helper entry: 1. Open the IP Helper Global Configuration page. 2. Click Add to display the Add Helper IP Address page: 920 Configuring L2 and L3 Relay Features Figure 33-9. Add Helper IP Address 3. Select a UDP Destination port name from the menu or enter the UDP Destination Port ID. Select the Default Set to configure for the relay entry for the default set of protocols. NOTE: If the DefaultSet option is specified, the device by default forwards UDP Broadcast packets for the following services: IEN-116 Name Service (port 42), DNS (port 53), NetBIOS Name Server (port 137), NetBIOS Datagram Server (port 138), TACACS Server (Port 49), and Time Service (port 37). 4. Enter the IP address of the server to which the packets with the given UDP Destination Port will be relayed. 5. Click Apply. The UDP/Helper Relay is added and the device is updated. Configuring L2 and L3 Relay Features 921 IP Helper Interface Configuration Use the Interface Configuration page to add, show, or delete UDP Relay and Helper IP configuration for a specific interface. To display the page, click Routing → IP Helper → Interface Configuration in the navigation panel. Figure 33-10. IP Helper Interface Configuration Adding an IP Helper Entry to an Interface To add an IP helper entry to an interface: 1. Open the IP Helper Interface Configuration page. 2. Click Add to display the Add IP Helper Address page: 922 Configuring L2 and L3 Relay Features Figure 33-11. Add Helper IP Address 3. Select the interface to use for the relay. 4. Select a UDP Destination port name from the menu or enter the UDP Destination Port ID. Select the Default Set to configure for the relay entry for the default set of protocols. NOTE: If the DefaultSet option is specified, the device by default forwards UDP Broadcast packets for the following services: IEN-116 Name Service (port 42), DNS (port 53), NetBIOS Name Server (port 137), NetBIOS Datagram Server (port 138), TACACS Server (Port 49), and Time Service (port 37). 5. Choose whether to discard (True) or keep (False) packets arriving on the given interface with the given destination UDP port. 6. Enter the IP address of the server to which the packets with the given UDP Destination Port will be relayed. 7. Click Apply. The UDP/Helper Relay is added to the interface and the device is updated. Configuring L2 and L3 Relay Features 923 IP Helper Statistics Use the Statistics page to view UDP Relay Statistics for the switch. To display the page, click Routing → IP Helper → Statistics in the navigation panel. Figure 33-12. 924 IP Helper Statistics Configuring L2 and L3 Relay Features Configuring L2 and L3 Relay Features (CLI) This section provides information about the commands you use to configure L2 and L3 relay features on the switch. For more information about the commands, see the PowerConnect 7000 Series CLI Reference Guide at support.dell.com/manuals. Configuring L2 DHCP Relay Beginning in Privileged EXEC mode, use the following commands to configure switch and interface L2 DHCP relay settings. Command Purpose configure Enter global configuration mode. dhcp l2relay Globally enable L2 DHCP relay on the switch interface interface Enter interface configuration mode for the specified port or LAG. The interface variable includes the interface type and number, for example gigabitethernet 1/0/3. For a LAG, the interface type is port-channel. You can also specify a range of ports with the interface range command, for example, interface range gigabitethernet 1/0/8-12 configures interfaces 8, 9, 10, 11, and 12. dhcp l2relay Enable L2 DHCP relay on the port(s) or LAG(s). dhcp l2relay trust Configure the interface(s) to mandate Option-82 on receiving DHCP packets. exit Exit to Global Configuration mode. dhcp l2relay vlan vlan- Enable the L2 DHCP Relay agent for a set of VLANs. All DHCP packets which arrive on interfaces in the configured VLAN are subject to L2 Relay processing. dhcp l2relay circuit-id vlan vlan-range Enable setting the DHCP Option 82 Circuit ID for a VLAN. When enabled, the interface number is added as the Circuit ID in DHCP option 82. range Configuring L2 and L3 Relay Features 925 Command Purpose dhcp l2relay remote-id Enable setting the DHCP Option 82 Remote ID for a remoteId vlan vlan-range VLAN. When enabled, the supplied string is used for the Remote ID in DHCP Option 82. The remoteId variable is a string to be used as the remote ID in the Option 82 (Range: 1 - 128 characters). exit Exit to Privileged EXEC mode. show dhcp l2relay all View L2 DHCP relay settings on the switch. View L2 DHCP relay settings for all interfaces or for the show dhcp l2relay interface [all | interface] specified interface. show dhcp l2relay vlan vlan-range View L2 DHCP relay settings for the specified VLAN show dhcp l2relay stats View the number of DHCP packets processed and relayed interface [all | interface] by the L2 relay agent. To reset the statistics to 0, use the clear dhcp l2relay statistics interface [all | interface] command. show dhcp l2relay agent- View the DHCP L2 Relay Option-82 configuration for the option vlan vlan-id specified VLAN. show dhcp l2relay circuit-id vlan vlan-id View the DHCP L2 Relay circuit ID configuration for the specified VLAN. show dhcp l2relay remote-id vlan vlan-id View the DHCP L2 Relay remote ID configuration for the specified VLAN. 926 Configuring L2 and L3 Relay Features Configuring L3 Relay (IP Helper) Settings Beginning in Privileged EXEC mode, use the following commands to configure switch and interface L3 DHCP relay and IP helper settings. Command Purpose configure Enter global configuration mode. ip helper enable Use this command to enable the IP helper feature. It is enabled by default. ip helper-address serveraddress [dest-udp-port | dhcp | domain | isakmp | mobile-ip | nameserver | netbiosdgm | netbios-ns | ntp | pim-auto-rp | rip | tacacs | tftp | time] Configure the relay of certain UDP broadcast packets received on any interface. Specify the one of the protocols defined in the command or the UDP port number. interface vlan vlan-id Enter interface configuration mode for the specified VLAN routing interface. • server-address — The IPv4 unicast or directed broadcast address to which relayed UDP broadcast packets are sent. The server address cannot be an IP address configured on any interface of the local router. • dest-udp-port — A destination UDP port number from 0 to 65535. You can also specify a range of VLAN routing interfaces with the interface range vlan command, for example, interface range vlan 10,20,30 configures VLAN interfaces 10, 20, and 30. NOTE: All VLANs must be configured as VLAN routing interfaces. Configuring L2 and L3 Relay Features 927 Command Purpose ip helper-address {server-address | discard} [dest-udp-port | dhcp | domain | isakmp | mobile-ip | nameserver | netbiosdgm | netbios-ns | ntp | pim-auto-rp | rip | tacacs | tftp | time] Configure the relay of certain UDP broadcast packets received on the VLAN routing interface(s). This command takes precedence over an ip helper-address command given in global configuration mode. Specify the one of the protocols defined in the command or the UDP port number. • server-address — The IPv4 unicast or directed broadcast address to which relayed UDP broadcast packets are sent. The server address cannot be an IP address configured on any interface of the local router. • dest-udp-port — A destination UDP port number from 0 to 65535. exit Exit to Global Config mode. exit Exit to Privileged EXEC mode. show ip helper-address [vlan vlan-id] View IP helper (L3 relay) settings for all interfaces or for the specified VLAN routing interface. show ip helper statistics View the number of DHCP and other UDP packets processed and relayed by the UDP relay agent. To reset the statistics to 0, use the clear ip helper statistics command. 928 Configuring L2 and L3 Relay Features Relay Agent Configuration Example The example in this section shows how to configure the L3 relay agent (IP helper) to relay and discard various protocols. Figure 33-13. L3 Relay Network Diagram DHCP Server 192.168.40.22 DNS Server 192.168.40.43 DHCP Server 192.168.40.35 SNMP Server 192.168.23.1 VLAN 30 L3 Switch ` DHCP Clients VLAN 10 ` ` ` VLAN 20 (No DHCP) This example assumes that multiple VLAN routing interfaces have been created, and configured with IP addresses. To configure the switch: 1 Relay DHCP packets received on VLAN 10 to 192.168.40.35 console#config console(config)#interface vlan 10 console(config-if-vlan10)#ip helper-address 192.168.40.35 dhcp Configuring L2 and L3 Relay Features 929 2 Relay DNS packets received on VLAN 10 to 192.168.40.43 console(config-if-vlan10)#ip helper-address 192.168.40.35 domain console(config-if-vlan10)#exit 3 Relay SNMP traps (port 162) received on VLAN 20 to 192.168.23.1 console(config)#interface vlan 20 console(config-if-vlan20)#ip helper-address 192.168.23.1 162 4 The clients on VLAN 20 have statically-configured network information, so the switch is configured to drop DHCP packets received on VLAN 20 console(config-if-vlan20)#ip helper-address discard dhcp console(config-if-vlan20)#exit 5 DHCP packets received from clients in any VLAN other than VLAN 10 and VLAN 20 are relayed to 192.168.40.22. NOTE: The following command is issued in Global Configuration mode, so it applies to all interfaces except VLAN 10 and VLAN 20. IP helper commands issued in Interface Configuration mode override the commands issued in Global Configuration Mode. console(config)#ip helper-address 192.168.40.22 dhcp 6 Verify the configuration. console#show ip helper-address IP helper is enabled I/F ---Vl10 Vl10 Vl20 Vl20 Any 930 UDP Port -------domain dhcp dhcp 162 dhcp Discard ----No No Yes No No Hit Count --------0 0 0 0 0 Configuring L2 and L3 Relay Features Server Address --------------192.168.40.43 192.168.40.35 192.168.23.1 192.168.40.22 34 Configuring OSPF and OSPFv3 This chapter describes how to configure Open Shortest Path First (OSPF) and OSPFv3. OSPF is a dynamic routing protocol for IPv4 networks, and OSPFv3 is used to route traffic in IPv6 networks. The protocols are configured separately within the software, but their functionality is largely similar for IPv4 and IPv6 networks. NOTE: In this chapter references to OSPF apply to OSPFv2 and OSPFv3 unless otherwise noted. The topics covered in this chapter include: • OSPF Overview • OSPF Feature Details • Default OSPF Values • Configuring OSPF Features (Web) • Configuring OSPFv3 Features (Web) • Configuring OSPF Features (CLI) • Configuring OSPFv3 Features (CLI) • OSPF Configuration Examples Configuring OSPF and OSPFv3 931 OSPF Overview OSPF is an Interior Gateway Protocol (IGP) that performs dynamic routing within a network. PowerConnect 7000 Series switches support two dynamic routing protocols: OSPF and Routing Information Protocol (RIP). Unlike RIP, OSPF is a link-state protocol. Larger networks typically use the OSPF protocol instead of RIP. What Are OSPF Areas and Other OSPF Topology Features? The top level of the hierarchy of an OSPF network is known as an OSPF domain. The domain can be divided into areas. Routers within an area must share detailed information on the topology of their area, but require less detailed information about the topology of other areas. Segregating a network into areas enables limiting the amount of route information communicated throughout the network. Areas are identified by a numeric ID in IP address format n.n.n.n (note, however, that these are not used as actual IP addresses). For simplicity, the area can be configured and referred to in normal integer notation. For example, Area 20 is identified as 0.0.0.20 and Area 256 as 0.0.1.0. The area identified as 0.0.0.0 is referred to as Area 0 and is considered the OSPF backbone. All other OSPF areas in the network must connect to Area 0 directly or through a virtual link. The backbone area is responsible for distributing routing information between non-backbone areas. A virtual link can be used to connect an area to Area 0 when a direct link is not possible. A virtual link traverses an area between the remote area and Area 0. A stub area is an area that does not accept external LSAs (LSAs generated by redistributing routes) that were learned from a protocol other than OSPF or were statically configured. These routes typically send traffic outside the AS. Therefore, routes from a stub area to locations outside the AS use the default gateway. A virtual link cannot be configured across a stub area. A Not So Stubby Area can import limited external routes only from a connected ASBR. 932 Configuring OSPF and OSPFv3 What Are OSPF Routers and LSAs? When a PowerConnect switch is configured to use OSPF for dynamic routing, it is considered to be an OSPF router. OSPF routers keep track of the state of the various links they send data to. Routers exchange OSPF link state advertisements (LSAs) with other routers. External LSAs provide information on static routes or routes learned from other routing protocols. OSPF defines various router types: • Backbone routers have an interface in Area 0. • Area border routers (ABRs) have interfaces in multiple areas. • Internal routers have all their interfaces in a single OSPF area. • Autonomous system boundary routers (ASBRs) redistribute routes from other protocols and originate external LSAs. How Are Routes Selected? OSPF determines the best route using the route metric and the type of the OSPF route. The following order is used for choosing a route if more than one type of route exists: 1 Intra-area (the destination prefix is in the same area as the router computing the route) 2 Inter-area (the destination is not in the same area as the router computing the route 3 External Type 1 4 External Type 2 How Are OSPF and OSPFv3 Different? OSPFv3 is the Open Shortest Path First routing protocol for IPv6. It is similar to OSPFv2 in its concept of a link state database, intra/inter area, and AS external routes and virtual links. It differs from its IPv4 counterpart in a number of respects. Peering is done through link-local addresses, and the protocol is link rather than network centric; and addressing semantics have been moved to leaf LSAs. Configuring OSPF and OSPFv3 933 OSPF Feature Details This section provides details on the following OSPF features: • Max Metric • Static Area Range Cost • LSA Pacing • LSA Pacing Max Metric RFC 3137 introduced stub router behavior to OSPFv2. As a stub, a router can inform other routers that it is not available to forward data packets. This can be useful if OSPF has run out of resources (for example, memory) to compute a complete routing table, or to avoid routing transients as OSPF learns its neighbors and a complete set of routes at startup. Thus, OSPF can enter stub router mode either automatically (as a result of a resource condition) or by configuration. When OSPF enters stub router mode, it re-originates its router LSAs and sets the metric on each of its non-stub links to the maximum value, 0xFFFF. Whenever OSPF originates a router LSA while in stub router mode, it sets the metrics in this way. Stub router mode is global and applies to router LSAs for all areas. Other routers prefer alternate paths that avoid the stub router; however, if no alternate path is available, another router may compute a transit route through a stub router. Because the stub router does not adjust the metric for stub links in its router LSA, routes to destinations on these networks are unaffected. Thus, stub router mode does not affect management connections to the router, even if the router and management station depend on OSPF routes to communicate with each other. The feature supports two modes of operation. The network administrator can put OSPF in stub router mode. OSPF remains in stub router mode until the network administrator takes OSPF out of stub router mode. Alternatively, the network administrator can configure OSPF to start in stub router mode for a configurable period of time after the router boots up. On a stack, the startup period also applies when a unit takes over as the management unit. The clear configuration command also restarts OSPF in stub router 934 Configuring OSPF and OSPFv3 mode. OSPF does not begin in stub router mode when OSPF is globally enabled. If the operator wants to avoid routing transients when he enables or configures OSPF, he can manually set OSPF in stub router mode. If OSPF is in startup stub router mode and encounters a resource limitation that would normally cause OSPF to become a stub router, OSPF cancels the timer to exit startup stub router and remains in stub router mode until the network administrator takes action. The network administrator can optionally configure OSPF to override the metric in summary LSAs while in stub router mode. The option applies to both type 3 and type 4 summary LSAs. When a router is in stub router mode, all its virtual links are down. This is because the cost to the virtual neighbor is guaranteed to be greater than or equal to 0xFFFF. RFC 2328 section 15 states that: “...a virtual link whose underlying path has cost greater than hexadecimal 0xffff (the maximum size of an interface cost in a router-LSA) should be considered non-operational.” To configure a router for stub router mode, use the max-metric routerlsa command in Global Router Configuration mode. The following example sets the router to start in stub router mode on a restart and remain in stub router mode for 5 minutes: ABR-R0(config)#router ospf ABR-R0(config-router)#max-metric router-lsa on-startup 300 The following example sets the router to advertise the metric in type 3 and type 4 summary LSAs as 32768 for 5 minutes after a restart, after which time the router will exit stub router mode and advertise the full set of LSAs: ABR-R0(config)#router ospf ABR-R0(config-router)#max-metric router-lsa on-startup 300 summarylsa 32768 The following example causes the router to exit stub router mode, whether entered automatically due to resource constraints or due to configuration by the operator. Virtual links are enabled when the router exits stub router mode. ABR-R0(config)#router ospf ABR-R0(config-router)#no max-metric router-lsa Configuring OSPF and OSPFv3 935 Static Area Range Cost This feature allows a network operator to configure a fixed OSPF cost that is always advertised when an area range is active. This feature applies to both OSPFv2 and OSPFv3. An OSPF domain can be divided into areas to limit the processing required on each router. Area Border Routers (ABRs) advertise reachability across area boundaries. It is common to summarize the set of prefixes that an ABR advertises across an area boundary. RFC 2328 specifies that when an ABR originates a type 3 LSA for an active area range, the cost in the LSA is set to “the largest cost of any of the component networks.” Thus, when an area's topology changes in a way that increases the largest cost, the type 3 LSA must be re-originated. In some cases, advertising the change in cost may be less important than preventing the topology change from propagating outside the area (thus causing routers in other areas to process and flood a changed LSA and rerun their routing table calculations). For this reason, it is common to give the network administrator the option of configuring the cost for an area range. When a static cost is configured, the cost advertised in the type 3 LSA does not depend on the cost of the component networks. Thus, topology changes within an area do not propagate outside the area, resulting in greater stability within the OSPF domain. PowerConnect switches also use area ranges to summarize type 7 LSAs when they are translated to type 5 LSAs. The cost option may be configured on area ranges used for type 7 to type 5 translation. If an area range is configured for type 3 summarization and the static cost is set to the maximum value, 16,777,215, the range is not advertised. Setting this static cost is equivalent to configuring a range with the not-advertise option. A summary LSA with this metric (LSInfinity) cannot be advertised, according to RFC 2328 section 12.4.3. This behavior is consistent with the industry standard. If an area range is configured for type 7 to type 5 translation, a type 5 LSA is sent if the metric is set to 16,777,215; however, other routers will not compute a route from a type 5 LSA with this metric. See "Configuring the Static Area Range Cost" on page 1009 for a configuration example. 936 Configuring OSPF and OSPFv3 LSA Pacing OSPF refreshes each self-originated LSA every 30 minutes. Because a router tends to originate many LSAs at the same time, either at startup or when adjacencies are formed or when routes are first learned, LSA refreshes tend to be grouped. Further, Area Border Routers (ABRs) attached to the same area tend to originate summary LSAs into the area at the same time. This behavior leads to periodic bursts of LS Update packets. Update bursts can lead to high CPU utilization, packet loss, and retransmission, if a receiver cannot absorb all packets in a burst. These losses occur primarily in two places: 1) at the Class of Service (CoS) queue where the hardware queues packets to the CPU, and 2) when a message buffer is allocated for an incoming packet. This feature makes changes to OSPFv2 to improve the efficiency of LSA flooding, with the expectation that the improvements will greatly reduce or eliminate the packet drops caused by bursts in OSPF control packets. The changes are as follows: • Introduce LSA transmit pacing, limiting the rate of LS Update packets that OSPF can send • Introduce LSA refresh groups, so that OSPF efficiently bundles LSAs into LS Update packets when periodically refreshing self-originated LSAs To configure LSA transmit pacing, use the timers pacing flood command in router config mode: ABR-R0(config)#router ospf ABR-R0(config-router)#timers pacing flood 50 This will cause LSA Update packets to be sent at no less than a 50 millisecond interval. When OSPF refreshes LSAs, it considers all self-originated LSAs whose age is from 1800 to 1800 plus the pacing group size. Grouping LSAs for refresh allows OSPF to combine refreshed LSAs into a minimal number of LS Update packets. Minimizing the number of Update packets makes LSA distribution more efficient. To configure an LSA Refresh window, use the timers pacing lsa-group command in router-config mode: ABR-R0(config)#router ospf ABR-R0(config-router)#timers pacing lsa-group 300 This sets the LSA Refresh window to 2100 seconds or about 35 minutes. Configuring OSPF and OSPFv3 937 Flood Blocking OSPF is a link state routing protocol. Routers describe their local environment in Link State Advertisements (LSAs), which are distributed throughout an area or OSPF domain. Through this process, each router learns enough information to compute a set of routes consistent with the routes computed by all other routers. Normally, OSPF floods an LSA on all interfaces within the LSA's flooding scope. Flooding ensures that all routers receive all LSAs. A router normally receives a duplicate copy of each LSA once on each interface in the LSA's flooding scope. The duplicate deliveries make OSPF LSA distribution robust, but in highly interconnected networks, can cause a lot of buffer and CPU usage. Buffer and CPU use can be reduced by selectively blocking LSA flooding on some interfaces, while ensuring that LSAs are flooded on enough interfaces to guarantee delivery of all LSAs to all routers. When enabling flood blocking, the network administrator must ensure there is sufficient LSA flooding even when there are router and link failures. This feature enables a network administrator to disable LSA flooding on an interface. Flood blocking only affects flooding of LSAs with area or AS (i.e., domain-wide) scope. Such LSAs are expected to be flooded to neighbors on other, unblocked interfaces, and eventually reach neighbors on blocked interfaces. An LSA with interface flooding scope cannot be blocked; there is no other way for interface-scope LSAs to reach neighbors on the blocked interface. Allowing interface-scope LSAs on blocked interfaces allows graceful restart to work, even if the restarting router has neighbors on flood blocked interfaces. When an interface is blocked, LSAs with area or AS scope are not sent to any neighbor on that interface. When flood blocking is enabled, OSPF does not advertise any LSAs with area or AS scope in its database description packets sent to neighbors on a blocked interface. When OSPF receives an LSA from a neighbor and the local database copy is newer than the received LSA, OSPF normally sends the newer LSA directly to the neighbor. If the neighbor is on a blocked interface, OSPF neither acknowledges the LSA nor sends the newer LSA. Instead, OSPF expects that the neighbor will receive the newer LSA indirectly. Flooding is enabled by default. 938 Configuring OSPF and OSPFv3 Flood blocking cannot be enabled on virtual interfaces. While the feature could be allowed on virtual interfaces, it is less likely to be used on a virtual interface, since virtual interfaces are created specifically to allow flooding between two backbone routers. So the option of flood blocking on virtual interfaces is not supported. See "Configuring Flood Blocking" on page 1014 for a configuration example. Configuring OSPF and OSPFv3 939 Default OSPF Values OSPF is globally enabled by default. To make it operational on the router, you must configure a router ID and enable OSPF on at least one interface. Table 34-1 shows the global default values for OSPF and OSPFv3. Table 34-1. OSPF/OSPFv3 Global Defaults Parameter Default Value Router ID None Admin Mode Enabled RFC 1583 Compatibility Enabled (OSPFv2 only) ABR Status Enabled Opaque LSA Status Enabled (OSPFv2 only) Exit Overflow Interval Not configured SPF Delay Time 5 (OSPFv2 only) SPF Hold Time 10 (OSPFv2 only) External LSDB Limit None Default Metric Not configured Maximum Paths 4 AutoCost Reference Bandwidth 100 Mbps Default Passive Setting Disabled Default Information Originate Disabled Non-Stop Forwarding (NSF) Support Disabled 940 Configuring OSPF and OSPFv3 Table 34-2 shows the per-interface default values for OSPF and OSPFv3. Table 34-2. OSPF Per-Interface Defaults Parameter Default Value Admin Mode Disabled Advertise Secondaries Enabled (OSPFv2 only) Router Priority 1 Retransmit Interval 5 seconds Hello Interval 10 seconds Dead Interval 40 seconds LSA Ack Interval 1 second Interface Delay Interval 1 second MTU Ignore Disabled Passive Mode Disabled Network Type Broadcast Authentication Type None (OSPFv2 only) Metric Cost Not configured Configuring OSPF and OSPFv3 941 Configuring OSPF Features (Web) This section provides information about the OpenManage Switch Administrator pages for configuring and monitoring OSPF features on a PowerConnect 7000 Series switch. For details about the fields on a page, click at the top of the page. OSPF Configuration Use the Configuration page to enable OSPF on a router and to configure the related OSPF settings. To display the page, click Routing → OSPF → Configuration in the navigation panel. Figure 34-1. OSPF Configuration 942 Configuring OSPF and OSPFv3 OSPF Area Configuration The Area Configuration page lets you create a Stub area configuration and NSSA once you’ve enabled OSPF on an interface through Routing → OSPF → Interface Configuration. At least one router must have OSPF enabled for this web page to display. To display the page, click Routing → OSPF → Area Configuration in the navigation panel. If a Stub Area has been created, the fields in the Stub Area Information are available. If a NSSA has been created, the fields in the NSSA Area Information are available. Figure 34-2. OSPF Area Configuration Configuring OSPF and OSPFv3 943 Configuring an OSPF Stub Area To configure the area as an OSPF stub area, click Create Stub Area. The pages refreshes, and displays additional fields that are specific to the stub area. Figure 34-3. OSPF Stub Area Configuration Use the Delete Stub Area button to remove the stub area. 944 Configuring OSPF and OSPFv3 Configuring an OSPF Not-So-Stubby Area To configure the area as an OSPF not-so-stubby area (NSSA), click NSSA Create. The pages refreshes, and displays additional fields that are specific to the NSSA. Figure 34-4. OSPF NSSA Configuration Use the NSSA Delete button to remove the NSSA area. Configuring OSPF and OSPFv3 945 OSPF Stub Area Summary The Stub Area Summary page displays OSPF stub area detail. To display the page, click Routing → OSPF → Stub Area Summary in the navigation panel. Figure 34-5. OSPF Stub Area Summary 946 Configuring OSPF and OSPFv3 OSPF Area Range Configuration Use the Area Range Configuration page to configure and display an area range for a specified NSSA. To display the page, click Routing → OSPF → Area Range Configuration in the navigation panel. Figure 34-6. OSPF Area Range Configuration Configuring OSPF and OSPFv3 947 OSPF Interface Statistics Use the Interface Statistics page to display statistics for the selected interface. The information is displayed only if OSPF is enabled. To display the page, click Routing → OSPF → Interface Statistics in the navigation panel. Figure 34-7. OSPF Interface Statistics 948 Configuring OSPF and OSPFv3 OSPF Interface Configuration Use the Interface Configuration page to configure an OSPF interface. To display the page, click Routing → OSPF → Interface Configuration in the navigation panel. Figure 34-8. OSPF Interface Configuration Configuring OSPF and OSPFv3 949 OSPF Neighbor Table Use the Neighbor Table page to display the OSPF neighbor table list. When a particular neighbor ID is specified, detailed information about a neighbor is given. The information below is only displayed if OSPF is enabled. To display the page, click Routing → OSPF → Neighbor Table in the navigation panel. Figure 34-9. OSPF Neighbor Table 950 Configuring OSPF and OSPFv3 OSPF Neighbor Configuration Use the Neighbor Configuration page to display the OSPF neighbor configuration for a selected neighbor ID. When a particular neighbor ID is specified, detailed information about a neighbor is given. The information below is only displayed if OSPF is enabled and the interface has a neighbor. The IP address is the IP address of the neighbor. To display the page, click Routing → OSPF → Neighbor Configuration in the navigation panel. Figure 34-10. OSPF Neighbor Configuration Configuring OSPF and OSPFv3 951 OSPF Link State Database Use the Link State Database page to display OSPF link state, external LSDB table, and AS opaque LSDB table information. To display the page, click Routing → OSPF → Link State Database in the navigation panel. Figure 34-11. OSPF Link State Database OSPF Virtual Link Configuration Use the Virtual Link Configuration page to create or configure virtual interface information for a specific area and neighbor. A valid OSPF area must be configured before this page can be displayed. To display the page, click Routing → OSPF → Virtual Link Configuration in the navigation panel. 952 Configuring OSPF and OSPFv3 Figure 34-12. OSPF Virtual Link Creation After you create a virtual link, additional fields display, as the Figure 34-13 shows. Figure 34-13. OSPF Virtual Link Configuration Configuring OSPF and OSPFv3 953 OSPF Virtual Link Summary Use the Virtual Link Summary page to display all of the configured virtual links. To display the page, click Routing → OSPF → Virtual Link Summary in the navigation panel. Figure 34-14. 954 OSPF Virtual Link Summary Configuring OSPF and OSPFv3 OSPF Route Redistribution Configuration Use the Route Redistribution Configuration page to configure redistribution in OSPF for routes learned through various protocols. You can choose to redistribute routes learned from all available protocols or from selected ones. To display the page, click Routing → OSPF → Route Redistribution Configuration in the navigation panel. Figure 34-15. OSPF Route Redistribution Configuration Configuring OSPF and OSPFv3 955 OSPF Route Redistribution Summary Use the Route Redistribution Summary page to display OSPF Route Redistribution configurations. To display the page, click Routing → OSPF → Route Redistribution Summary in the navigation panel. Figure 34-16. 956 OSPF Route Redistribution Summary Configuring OSPF and OSPFv3 NSF OSPF Configuration Use the NSF OSPF Configuration page to configure the non-stop forwarding (NSF) support mode and to view NSF summary information for the OSPF feature. NSF is a feature used in switch stacks to maintain switching and routing functions in the event of a stack unit failure. For information about NSF, see "What is Nonstop Forwarding?" on page 147 in the Managing a Switch Stack chapter. To display the page, click Routing → OSPF → NSF OSPF Configuration in the navigation panel. Figure 34-17. NSF OSPF Configuration Configuring OSPF and OSPFv3 957 Configuring OSPFv3 Features (Web) This section provides information about the OpenManage Switch Administrator pages for configuring and monitoring OSPFv3 features on a PowerConnect 7000 Series switch. For details about the fields on a page, click at the top of the page. OSPFv3 Configuration Use the Configuration page to activate and configure OSPFv3 for a switch. To display the page, click IPv6 → OSPFv3 → Configuration in the navigation panel. Figure 34-18. 958 OSPFv3 Configuration Configuring OSPF and OSPFv3 OSPFv3 Area Configuration Use the Area Configuration page to create and configure an OSPFv3 area. To display the page, click IPv6 → OSPFv3 → Area Configuration in the navigation panel. Figure 34-19. OSPFv3 Area Configuration Configuring OSPF and OSPFv3 959 Configuring an OSPFv3 Stub Area To configure the area as an OSPFv3 stub area, click Create Stub Area. The pages refreshes, and displays additional fields that are specific to the stub area. Figure 34-20. OSPFv3 Stub Area Configuration Use the Delete Stub Area button to remove the stub area. 960 Configuring OSPF and OSPFv3 Configuring an OSPFv3 Not-So-Stubby Area To configure the area as an OSPFv3 not-so-stubby area (NSSA), click Create NSSA. The pages refreshes, and displays additional fields that are specific to the NSSA. Figure 34-21. OSPFv3 NSSA Configuration Use the Delete NSSA button to remove the NSSA area. Configuring OSPF and OSPFv3 961 OSPFv3 Stub Area Summary Use the Stub Area Summary page to display OSPFv3 stub area detail. To display the page, click IPv6 → OSPFv3 → Stub Area Summary in the navigation panel. Figure 34-22. 962 OSPFv3 Stub Area Summary Configuring OSPF and OSPFv3 OSPFv3 Area Range Configuration Use the Area Range Configuration page to configure OSPFv3 area ranges. To display the page, click IPv6 → OSPFv3 → Area Range Configuration in the navigation panel. Figure 34-23. OSPFv3 Area Range Configuration Configuring OSPF and OSPFv3 963 OSPFv3 Interface Configuration Use the Interface Configuration page to create and configure OSPFv3 interfaces. This page has been updated to include the Passive Mode field. To display the page, click IPv6 → OSPFv3 → Interface Configuration in the navigation panel. Figure 34-24. 964 OSPFv3 Interface Configuration Configuring OSPF and OSPFv3 OSPFv3 Interface Statistics Use the Interface Statistics page to display OSPFv3 interface statistics. Information is only displayed if OSPF is enabled. Several fields have been added to this page. To display the page, click IPv6 → OSPFv3 → Interface Statistics in the navigation panel. Figure 34-25. OSPFv3 Interface Statistics Configuring OSPF and OSPFv3 965 OSPFv3 Neighbors Use the Neighbors page to display the OSPF neighbor configuration for a selected neighbor ID. When a particular neighbor ID is specified, detailed information about that neighbor is given. Neighbor information only displays if OSPF is enabled and the interface has a neighbor. The IP address is the IP address of the neighbor. To display the page, click IPv6 → OSPFv3 → Neighbors in the navigation panel. Figure 34-26. 966 OSPFv3 Neighbors Configuring OSPF and OSPFv3 OSPFv3 Neighbor Table Use the Neighbor Table page to display the OSPF neighbor table list. When a particular neighbor ID is specified, detailed information about a neighbor is given. The neighbor table is only displayed if OSPF is enabled. To display the page, click IPv6 → OSPFv3 → Neighbor Table in the navigation panel. Figure 34-27. OSPFv3 Neighbor Table Configuring OSPF and OSPFv3 967 OSPFv3 Link State Database Use the Link State Database page to display the link state and external LSA databases. The OSPFv3 Link State Database page has been updated to display external LSDB table information in addition to OSPFv3 link state information. To display the page, click IPv6 → OSPFv3 → Link State Database in the navigation panel. Figure 34-28. 968 OSPFv3 Link State Database Configuring OSPF and OSPFv3 OSPFv3 Virtual Link Configuration Use the Virtual Link Configuration page to define a new or configure an existing virtual link. To display this page, a valid OSPFv3 area must be defined through the OSPFv3 Area Configuration page. To display the page, click IPv6 → OSPFv3 → Virtual Link Configuration in the navigation panel. Figure 34-29. OSPFv3 Virtual Link Configuration Configuring OSPF and OSPFv3 969 After you create a virtual link, additional fields display, as the Figure 34-30 shows. Figure 34-30. 970 OSPFv3 Virtual Link Configuration Configuring OSPF and OSPFv3 OSPFv3 Virtual Link Summary Use the Virtual Link Summary page to display virtual link data by Area ID and Neighbor Router ID. To display the page, click IPv6 → OSPFv3 → Virtual Link Summary in the navigation panel. Figure 34-31. OSPFv3 Virtual Link Summary Configuring OSPF and OSPFv3 971 OSPFv3 Route Redistribution Configuration Use the Route Redistribution Configuration page to configure route redistribution. To display the page, click IPv6 → OSPFv3 → Route Redistribution Configuration in the navigation panel. Figure 34-32. 972 OSPFv3 Route Redistribution Configuration Configuring OSPF and OSPFv3 OSPFv3 Route Redistribution Summary Use the Route Redistribution Summary page to display route redistribution settings by source. To display the page, click IPv6 → OSPFv3 → Route Redistribution Summary in the navigation panel. Figure 34-33. OSPFv3 Route Redistribution Summary Configuring OSPF and OSPFv3 973 NSF OSPFv3 Configuration Use the NSF OSPFv3 Configuration page to configure the non-stop forwarding (NSF) support mode and to view NSF summary information for the OSPFv3 feature. NSF is a feature used in switch stacks to maintain switching and routing functions in the event of a stack unit failure. For information about NSF, see "What is Nonstop Forwarding?" on page 147 in the Managing a Switch Stack chapter. To display the page, click Routing → OSPFv3 → NSF OSPFv3 Configuration in the navigation panel. Figure 34-34. 974 NSF OSPFv3 Configuration Configuring OSPF and OSPFv3 Configuring OSPF Features (CLI) This section provides information about the commands you use to configure and view OSPF settings on the switch. This section does not describe all available show commands. For more information about all available OSPF commands, see the PowerConnect 7000 Series CLI Reference Guide at support.dell.com/manuals. Configuring Global OSPF Settings Beginning in Privileged EXEC mode, use the following commands to configure various global OSPF settings for the switch. Command Purpose configure Enter global configuration mode. router ospf Enter OSPF configuration mode. router-id ip-address Set the 4-digit dotted-decimal number that uniquely identifies the router. auto-cost referencebandwidth ref_bw Set the reference bandwidth used in the formula to compute link cost for an interface: link cost = ref_bw÷interface bandwidth The ref_bw variable is the reference bandwidth in Mbps (Range: 1–4294967). capability opaque Allow OSPF to store and flood opaque LSAs. An opaque LSA is used for flooding user defined information within an OSPF router domain. compatible rfc1583 (Optional) Enable compatibility with RFC 1583. If all OSPF routers in the routing domain are capable of operating according to RFC 2328, OSPF 1583 compatibility mode should be disabled. Configuring OSPF and OSPFv3 975 Command Purpose Control the advertisement of default routes. default-information originate [always] • always — Normally, OSPF originates a default route only [metric metric-value] if a default route is redistributed into OSPF (and default[metric-type type-value] information originate is configured). When the always option is configured, OSPF originates a default route, even if no default route is redistributed. • metric-value — The metric (or preference) value of the default route. (Range: 1–16777214) • type-value — The value is either 1 or 2: External type-1 route or External type-2 route. default-metric metric- value Set a default for the metric of distributed routes (Range: 1–16777214). distance ospf {external | Set the preference values of OSPF route types in the inter-area | intra-area } router. distance The range for the distance variable is 1–255. Lower route preference values are preferred when determining the best route. enable Enable OSPF. exit-overflow-interval Specify the exit overflow interval for OSPF as defined in RFC 1765. seconds The interval is the number of seconds after entering overflow state that a router will wait before attempting to leave the overflow state. (Range: 0–2147483647) external-lsdb-limit limit Configure the external LSDB limit for OSPF as defined in RFC 1765. If the value is –1, then there is no limit. The limit variable is the maximum number of non-default AS external-LSAs allowed in the router's link-state database. (Range: 1 to 2147483647) maximum-paths integer Set the number of paths that OSPF can report for a given destination (Range: 1–4). 976 Configuring OSPF and OSPFv3 Command Purpose passive-interface default Configure OSPF interfaces as passive by default. This command overrides any interface-level passive mode settings.OSPF does not form adjacencies on passive interfaces but does advertise attached networks as stub networks. timers spf delay-time hold-time Specify the SPF delay and hold time. • delay-time — SPF delay time. (Range: 0–65535 seconds) • hold-time — SPF hold time. (Range: 0–65535 seconds) exit Exit to Global Configuration mode. exit Exit to Privileged EXEC mode. show ip ospf View OSPF global configuration and status. show ip ospf statistics View OSPF routing table calculation statistics. clear ip ospf Reset specific OSPF states. If no parameters are specified, [{configuration | OSPF is disabled and then re-enabled. redistribution | counters | neighbor [interface vlan vlan-id [neighbor-id]]}] Configuring OSPF and OSPFv3 977 Configuring OSPF Interface Settings Beginning in Privileged EXEC mode, use the following commands to configure per-interface OSPF settings. Command Purpose configure Enter global configuration mode. interface vlan vlan-id Enter Interface Configuration mode for the specified VLAN. ip ospf area area-id [secondaries none] Enables OSPFv2 on the interface and sets the area ID of an interface. This command supersedes the effects of network area command. The area-id variable is the ID of the area (Range: IP address or decimal from 0 –4294967295) Use the secondaries none keyword to prevent the interface from advertising its secondary addresses into the OSPFv2 domain. ip ospf priority number- Set the OSPF priority for the interface. The number-value value variable specifies the priority of an interface (Range: 0 to 255). The default priority is 1, which is the highest router priority. A value of 0 indicates that the router is not eligible to become the designated router on this network. ip ospf retransmitinterval seconds Set the OSPF retransmit interval for the interface. The seconds variable is the number of seconds between link-state advertisements for adjacencies belonging to this router interface. This value is also used when retransmitting database descriptions and link-state request packets. Valid values range from 0 to 3600 seconds (1 hour). ip ospf hello-interval seconds Set the OSPF hello interval for the interface. This parameter must be the same for all routers attached to a network. The seconds variable indicates the number of seconds to wait before sending Hello packets from the interface. (Range: 1–65535). 978 Configuring OSPF and OSPFv3 Command Purpose ip ospf dead-interval Set the OSPF dead interval for the interface. seconds The seconds variable indicates the number of seconds a router waits to see a neighbor router's Hello packets before declaring that the router is down (Range: 1–65535). This parameter must be the same for all routers attached to a network. This value should be some multiple of the Hello Interval. ip ospf transmit-delay seconds Set the OSPF Transit Delay for the interface. The seconds variable sets the estimated number of seconds it takes to transmit a link state update packet over this interface. (Range: 1–3600 seconds) ip ospf mtu-ignore Disable OSPF MTU mismatch detection on the received database description. ip ospf network {broadcast | point-topoint} Set the OSPF network type on the interface to broadcast or point-to-point. OSPF selects a designated router and originates network LSAs only for broadcast networks. No more than two OSPF routers may be present on a pointto-point link. ip ospf authentication {none | {simple key} | {encrypt key key-id}} Set the OSPF Authentication Type and Key for the specified interface. • encrypt — MD5 encrypted authentication key. • key — Authentication key for the specified interface. (Range: 8 bytes or less if the authentication type is simple and 16 bytes or less if the type is encrypt.) • key-id — Authentication key identifier for the authentication type encrypt. (Range: 0–25) ip ospf cost interface- cost bandwidth bw Set the metric cost of the interface. The interface-cost variable specifies the cost (link-state metric) of the OSPF interface. (Range: 1–65535) Set the interface bandwidth used in the formula to compute link cost for an interface: link cost = ref_bw÷interface bandwidth The bw variable is the interface bandwidth (Range: 1–10000000 Kbps). Configuring OSPF and OSPFv3 979 Command Purpose exit Exit to Global Configuration Mode router ospf Enter OSPF configuration mode. passive-interface vlan Make an interface passive to prevent OSPF from forming an adjacency on an interface. OSPF advertises networks attached to passive interfaces as stub networks. vlan-id network ip-address Enable OSPFv2 on interfaces whose primary IP address wildcard-mask area area- matches this command, and make the interface a member id of the specified area. • ip-address — Base IPv4 address of the network area. • wildcard-mask — The network mask indicating the subnet. • area-id — The ID of the area (Range: IP address or decimal from 0–4294967295). exit Exit to Global Config mode. exit Exit to Privileged EXEC mode. show ip ospf interface [vlan vlan-id] View summary information for all OSPF interfaces configured on the switch or for the specified routing interface. show ip ospf interface stats vlan vlan-id View per-interface OSPF statistics. Configuring Stub Areas and NSSAs Beginning in Privileged EXEC mode, use the following commands to configure OSPF stub areas and NSSAs. Command Purpose configure Enter global configuration mode. router ospf Enter OSPF configuration mode. area area-id stub Create a stub area for the specified area ID. area area-id stub nosummary Prevent Summary LSAs from being advertised into the stub area. 980 Configuring OSPF and OSPFv3 Command Purpose area area-id default-cost integer Configure the metric value (default cost) for the type 3 summary LSA sent into the stub area. Range: 1–16777215) area area-id nssa Create an NSSA for the specified area ID. area area-id nssa nosummary Configure the NSSA so that summary LSAs are not advertised into the NSSA. area area-id nssa Configure the translator role of the NSSA. translator-role {always | • always — The router assumes the role of the translator candidate} when it becomes a border router. • candidate — The router can participate in the translator election process when it attains border router status. area area-id nssa translator-stab-intv Configure the translator stability interval of the NSSA. area area-id nssa defaultinformation-originate [metric metric-value] [metric-type metric-typevalue] Configure the metric value and type for the default route advertised into the NSSA. The metric type can be comparable (nssa-external 1) or non-comparable (nssaexternal 2). area area-id nssa no-redistribution Prevent learned external routes from being redistributed to the NSSA. exit Exit to Global Config mode. exit Exit to Privileged EXEC mode. integer The integer variable is the period of time that an elected translator continues to perform its duties after it determines that its translator status has been deposed by another router. (Range: 0–3600) show ip ospf area area-id View the configuration and status of an OSPF area. Configuring OSPF and OSPFv3 981 Configuring Virtual Links Beginning in Privileged EXEC mode, use the following commands to configure OSPF Virtual Links. Command Purpose configure Enter global configuration mode. router ospf Enter OSPF configuration mode. area area-id virtual-link Create the OSPF virtual interface for the specified areaid and neighbor router. The neighbor-id variable is the IP address of the neighboring router. area area-id virtual-link router-id [authentication [message-digest | null]] [[authentication-key key] | [message-digest-key keyid md5 key]] Create the OSPF virtual interface for the specified areaid and neighbor router. neighbor-id Use the optional parameters to configure authentication for the virtual link. If the area has not been previously created, it is created by this command. If the area already exists, the virtual-link information is added or modified. • authentication—Specifies authentication type. • message-digest—Specifies that message-digest authentication is used. • null—No authentication is used. Overrides password or message-digest authentication if configured for the area. • md5—Use MD5 Encryption for an OSPF Virtual Link • key—Authentication key for the specified interface. (Range: 8 bytes or less if the authentication type is simple and 16 bytes or less if the type is encrypt.) • key-id—Authentication key identifier for the authentication type encrypt. (Range: 0-255) area area-id virtual-link neighbor-id retransmitinterval seconds 982 Set the OSPF retransmit interval for the virtual link interface. The seconds variable is the number of seconds to wait between retransmitting LSAs if no acknowledgement is received. (Range: 0–3600) Configuring OSPF and OSPFv3 Command Purpose area area-id virtual-link Set the OSPF hello interval for the virtual link. neighbor-id hello-interval The seconds variable indicates the number of seconds to seconds wait before sending Hello packets from the virtual interface. (Range: 1–65535). Set the OSPF dead interval for the virtual link. area area-id virtual-link neighbor-id dead-interval The seconds variable indicates the number of seconds to seconds wait before the virtual interface is assumed to be dead. (Range: 1–65535) area area-id virtual-link neighbor-id transmitdelay seconds Set the OSPF Transit Delay for the interface. The seconds variable is the number of seconds to increment the age of the LSA before sending, based on the estimated time it takes to transmit from the interface. (Range: 0–3600) exit Exit to Global Config mode. exit Exit to Privileged EXEC mode. show ip ospf virtual-link brief View summary information about all virtual links configured on the switch. Configuring OSPF and OSPFv3 983 Configuring OSPF Area Range Settings Beginning in Privileged EXEC mode, use the following commands to configure an OSPF area range. Command Purpose configure Enter global configuration mode. router ospf Enter OSPF configuration mode. area area-id range Configure a summary prefix for routes learned in a given area. ip-address mask {summarylink | nssaexternallink} [advertise |not-advertise] • area-id — Identifies the OSPF NSSA to configure. (Range: IP address or decimal from 0–4294967295) • ip-address — IP address. • subnet-mask — Subnet mask associated with IP address. • summarylink — Specifies a summary link LSDB type. • nssaexternallink — Specifies an NSSA external link LSDB type. • advertise — Advertisement of the area range. • not-advertise — Suppresses advertisement of the area range. exit Exit to Global Config mode. exit Exit to Privileged EXEC mode. show ip ospf range View information about the area ranges for the specified area-id. area-id Configuring OSPF Route Redistribution Settings Beginning in Privileged EXEC mode, use the following commands to configure OSPF route redistribution settings. Command Purpose configure Enter global configuration mode. router ospf Enter OSPF configuration mode. 984 Configuring OSPF and OSPFv3 Command Purpose distribute-list Specify the access list to filter routes received from the static | connected} switch. For information about the commands you use to configure ACLs, see "Configuring ACLs (CLI)" on page 543. accesslistname out {rip | source protocol. The ACL must already exist on the • accesslistname — The name used to identify an existing ACL. • rip — Apply the specified access list when RIP is the source protocol. • static — Apply the specified access list when packets come through the static route. • connected — Apply the specified access list when packets come from a directly connected route. redistribute {rip | static | Configure OSPF to allow redistribution of routes from the specified source protocol/routers. connected} [metric integer] [metric-type {1 | • rip — Specifies RIP as the source protocol. 2}] [tag integer] [subnets] • static — Specifies that the source is a static route. • connected — Specifies that the source is a directly connected route. • metric — Specifies the metric to use when redistributing the route. (Range: 0–16777214) • metric-type 1 — Type 1 external route. • metric-type 2 — Type 2 external route. • tag — Value attached to each external route. (Range: 0–4294967295) • subnets—Unless this keyword is configured, OSPF distributes only class A, class B, and class C prefixes. exit Exit to Global Config mode. exit Exit to Privileged EXEC mode. show ip ospf View OSPF configuration and status information, including route distribution information. Configuring OSPF and OSPFv3 985 Configuring NSF Settings for OSPF Beginning in Privileged EXEC mode, use the following commands to configure the non-stop forwarding settings for OSPF. Command Purpose configure Enter global configuration mode. router ospf Enter OSPF configuration mode. nsf [ietf ] helper strict-lsa- Require that an OSPF helpful neighbor exit helper mode checking whenever a topology change occurs. Use the ietf keyword to distinguish the IETF standard implementation of graceful restart from other implementations. nsf [ietf ] restart-interval Configure the length of the grace period on the restarting router. seconds The seconds keyword is the number of seconds that the restarting router asks its neighbors to wait before exiting helper mode. The restarting router includes the restart interval in its grace LSAs (range 1–1800 seconds) nsf helper [planned-only] Allow OSPF to act as a helpful neighbor for a restarting router. Include the planned-only keyword to indicate that OSPF should only help a restarting router performing a planned restart. nsf [ietf] [planned-only] Enable a graceful restart of OSPF. • ietf — This keyword is used to distinguish the IETF standard implementation of graceful restart from other implementations. Since the IETF implementation is the only one supported, this keyword is optional. • planned-only — This keyword indicates that OSPF should only perform a graceful restart when the restart is planned (i.e., when the restart is a result of the initiate failover command). 986 Configuring OSPF and OSPFv3 Configuring OSPFv3 Features (CLI) This section provides information about the commands you use to configure OSPFv3 settings on the switch. For more information about the commands and about additional show commands, see the PowerConnect 7000 Series CLI Reference Guide at support.dell.com/manuals. Configuring Global OSPFv3 Settings Beginning in Privileged EXEC mode, use the following commands to configure various global OSPFv3 settings for the switch. Command Purpose configure Enter global configuration mode. ipv6 router ospf Enter OSPFv3 configuration mode. router-id ip-address Set the 4-digit dotted-decimal number that uniquely identifies the router. auto-cost referencebandwidth ref_bw Set the reference bandwidth used in the formula to compute link cost for an interface: link cost = ref_bw÷interface bandwidth The ref_bw variable is the reference bandwidth in Mbps (Range: 1–4294967). Control the advertisement of default routes. default-information originate [always] • always — Normally, OSPFv3 originates a default route [metric metric-value] only if a default route is redistributed into OSPFv3 (and [metric-type type-value] default-information originate is configured). When the always option is configured, OSPFv3 originates a default route, even if no default route is redistributed. • metric-value — The metric (or preference) value of the default route. (Range: 1–16777214) • type-value — The value is either 1 or 2: External type-1 route or External type-2 route. default-metric metric- value Set a default for the metric of distributed routes. (Range: 1–16777214). Configuring OSPF and OSPFv3 987 Command Purpose distance ospf {external | Set the preference values of OSPFv3 route types in the inter-area | intra-area } router. distance The range for the distance variable is 1–255. Lower route preference values are preferred when determining the best route. enable Enable OSPFv3. exit-overflow-interval Specify the exit overflow interval for OSPFv3 as defined in RFC 1765. seconds The interval is the number of seconds after entering overflow state that a router will wait before attempting to leave the overflow state. (Range: 0–2147483647) external-lsdb-limit limit Configure the external LSDB limit for OSPFv3 as defined in RFC 1765. If the value is -1, then there is no limit. The limit variable is the maximum number of non-default AS external-LSAs allowed in the router's link-state database. (Range: –1 to 2147483647) maximum-paths maxpaths Set the number of paths that OSPFv3 can report for a given destination. (Range: 1–4.) passive-interface default Configure OSPFv3 interfaces as passive by default. This command overrides any interface-level passive mode settings. OSPFv3 does not form adjacencies on passive interfaces but does advertise attached networks as stub networks. exit Exit to Global Configuration mode. exit Exit to Privileged EXEC mode. show ipv6 ospf View OSPFv3 global configuration and status. Reset specific OSPFv3 states. If no parameters are clear ipv6 ospf specified, OSPFv3 is disabled and then re-enabled. [{configuration | redistribution | counters | neighbor [interface vlan vlan-id [neighbor-id]]}] 988 Configuring OSPF and OSPFv3 Configuring OSPFv3 Interface Settings Beginning in Privileged EXEC mode, use the following commands to configure per-interface OSPFv3 settings. Command Purpose configure Enter global configuration mode. interface vlan vlan-id Enter Interface Configuration mode for the specified VLAN. ipv6 ospf areaid area-id Enables OSPFv3 on the interface and sets the area ID of an interface. This command supersedes the effects of network area command. The area-id variable is the ID of the area (Range: IP address or decimal from 0 –4294967295) ipv6 ospf priority number-value Set the OSPFv3 priority for the interface. The numbervalue variable specifies the priority of an interface (Range: 0 to 255). The default priority is 1, which is the highest router priority. A value of 0 indicates that the router is not eligible to become the designated router on this network. ipv6 ospf retransmitinterval seconds Set the OSPFv3 retransmit interval for the interface. The seconds variable is the number of seconds between link-state advertisements for adjacencies belonging to this router interface. This value is also used when retransmitting database descriptions and link-state request packets. Valid values range from 0 to 3600 seconds (1 hour). ipv6 ospf hello-interval seconds Set the OSPFv3 hello interval for the interface. This parameter must be the same for all routers attached to a network. The seconds variable indicates the number of seconds to wait before sending Hello packets from the interface. (Range: 1–65535). Configuring OSPF and OSPFv3 989 Command Purpose ipv6 ospf dead-interval Set the OSPFv3 dead interval for the interface. seconds The seconds variable indicates the number of seconds a router waits to see a neighbor router's Hello packets before declaring that the router is down (Range: 1–65535). This parameter must be the same for all routers attached to a network. This value should be some multiple of the Hello Interval. ipv6 ospf transmit-delay Set the OSPFv3 Transit Delay for the interface. seconds The seconds variable sets the estimated number of seconds it takes to transmit a link state update packet over this interface. (Range: 1–3600 seconds) ip ospf mtu-ignore Disable OSPFv3 MTU mismatch detection on received database description packets. ipv6 ospf network {broadcast | point-topoint } Set the OSPFv3 network type on the interface to broadcast or point-to-point. OSPFv3 selects a designated router and originates network LSAs only for broadcast networks. No more than two OSPFv3 routers may be present on a point-to-point link. ipv6 ospf cost interface- Set the metric cost of the interface. cost The interface-cost variable specifies the cost (link-state metric) of the OSPFv3 interface. (Range: 1–65535) bandwidth bw Set the interface bandwidth used in the formula to compute link cost for an interface: link cost = ref_bw÷interface bandwidth The bw variable is the interface bandwidth (Range: 1–10000000 Kbps). exit Exit to Global Configuration Mode ipv6 router ospf Enter OSPFv3 configuration mode. vlan-id | tunnel tunnelid} passive-interface {vlan Make an interface passive to prevent OSPFv3 from forming an adjacency on an interface. OSPFv3 advertises networks attached to passive interfaces as stub networks. exit Exit to Global Config mode. exit Exit to Privileged EXEC mode. 990 Configuring OSPF and OSPFv3 Command Purpose show ipv6 ospf interface View summary information for all OSPFv3 interfaces [interface-type interface- configured on the switch or for the specified routing number] interface. show ipv6 ospf interface View per-interface OSPFv3 statistics. stats interface-type interface-number Configuring Stub Areas and NSSAs Beginning in Privileged EXEC mode, use the following commands to configure OSPFv3 stub areas and NSSAs. Command Purpose configure Enter global configuration mode. ipv6 router ospf Enter OSPFv3 configuration mode. area area-id stub Create a stub area for the specified area ID. area area-id stub nosummary Prevent Summary LSAs from being advertised into the stub area. area area-id default-cost Configure the metric value (default cost) for the type 3 summary LSA sent into the stub area. Range: 1–16777215) cost Configuring OSPF and OSPFv3 991 Command Purpose area area-id nssa [noCreate and configure an NSSA for the specified area ID. redistribution] [default- • metric-value—Specifies the metric of the default route information-originate advertised to the NSSA. (Range: 1–16777214) [metric metric-value] [metric-type metric-type- • metric-type-value—The metric type can be one of the following : value]] [no-summary] [translator-role role] • A metric type of nssa-external 1 (comparable) [translator-stab-intv • A metric type of nssa-external 2 (non-comparable) interval] • no-summary—Summary LSAs are not advertised into the NSSA • role—The translator role where role is one of the following : • always—The router assumes the role of the translator when it becomes a border router. • candidate—The router to participate in the translator election process when it attains border router status. • interval—The period of time that an elected translator continues to perform its duties after it determines that its translator status has been deposed by another router. (Range: 0–3600) area area-id nssa no-redistribution Prevent learned external routes from being redistributed to the NSSA. exit Exit to Global Config mode. exit Exit to Privileged EXEC mode. show ipv6 ospf area area- Show configuration and status of an OSPF area. id 992 Configuring OSPF and OSPFv3 Configuring Virtual Links Beginning in Privileged EXEC mode, use the following commands to configure OSPFv3 Virtual Links. Command Purpose configure Enter global configuration mode. ipv6 router ospf Enter OSPFv3 configuration mode. area area-id virtual-link Create the OSPFv3 virtual interface for the specified area-id and neighbor router. The neighbor-id variable is the IP address of the neighboring router. area area-id virtual-link neighbor-id retransmitinterval seconds Set the OSPFv3 retransmit interval for the virtual link interface. neighbor-id The seconds variable is the number of seconds to wait between retransmitting LSAs if no acknowledgement is received. (Range: 0–3600) area area-id virtual-link Set the OSPFv3 hello interval for the virtual link. neighbor-id hello-interval The seconds variable indicates the number of seconds to seconds wait before sending Hello packets from the virtual interface. (Range: 1–65535). Set the OSPFv3 dead interval for the virtual link. area area-id virtual-link neighbor-id dead-interval The seconds variable indicates the number of seconds to seconds wait before the virtual interface is assumed to be dead. (Range: 1–65535) area area-id virtual-link neighbor-id transmitdelay seconds Set the OSPFv3 Transit Delay for the interface. The seconds variable is the number of seconds to increment the age of the LSA before sending, based on the estimated time it takes to transmit from the interface. (Range: 0–3600) exit Exit to Global Config mode. exit Exit to Privileged EXEC mode. show ipv6 ospf virtuallink brief View summary information about all virtual links configured on the switch. Configuring OSPF and OSPFv3 993 Configuring an OSPFv3 Area Range Beginning in Privileged EXEC mode, use the following commands to configure an OSPFv3 area range. Command Purpose configure Enter global configuration mode. ipv6 router ospf Enter OSPFv3 configuration mode. area area-id range ipv6- Configure a summary prefix for routes learned in a given area. prefix/prefix-length {summarylink | • area-id — Identifies the OSPFv3 NSSA to configure. nssaexternallink} (Range: IP address or decimal from 0–4294967295) [advertise |not-advertise] • ipv6-prefix/prefix-length — IPv6 address and prefix length. • summarylink — Specifies a summary link LSDB type. • nssaexternallink — Specifies an NSSA external link LSDB type. • advertise — Advertisement of the area range. • not-advertise — Suppresses advertisement of the area range. exit Exit to Global Config mode. exit Exit to Privileged EXEC mode. show ipv6 ospf range area- View information about the area ranges for the specified area-id. id 994 Configuring OSPF and OSPFv3 Configuring OSPFv3 Route Redistribution Settings Beginning in Privileged EXEC mode, use the following commands to configure OSPFv3 route redistribution settings. Command Purpose configure Enter global configuration mode. ipv6 router ospf Enter OSPFv3 configuration mode. redistribute {static | Configure OSPFv3 to allow redistribution of routes from connected} [metric the specified source protocol/routers. metric] [metric-type {1 | • static — Specifies that the source is a static route. 2}] [tag tag] • connected — Specifies that the source is a directly connected route. • metric — Specifies the metric to use when redistributing the route. (Range: 0–16777214) • metric-type 1 — Type 1 external route. • metric-type 2 — Type 2 external route. • tag — Value attached to each external route, which might be used to communicate information between ASBRs. (Range: 0–4294967295) exit Exit to Global Config mode. exit Exit to Privileged EXEC mode. show ipv6 ospf View OSPFv3 configuration and status information, including information about redistributed routes. Configuring OSPF and OSPFv3 995 Configuring NSF Settings for OSPFv3 Beginning in Privileged EXEC mode, use the following commands to configure the non-stop forwarding settings for OSPFv3. Command Purpose configure Enter global configuration mode. ipv6 router ospf Enter OSPFv3 configuration mode. nsf [ietf ] helper strict-lsa- Require that an OSPFv3 helpful neighbor exit helper checking mode whenever a topology change occurs. Use the ietf keyword to distinguish the IETF standard implementation of graceful restart from other implementations. nsf [ietf ] restart-interval Configure the length of the grace period on the restarting seconds router. The seconds keyword is the number of seconds that the restarting router asks its neighbors to wait before exiting helper mode. The restarting router includes the restart interval in its grace LSAs (range 1–1800 seconds) nsf helper [planned-only] Allow OSPFv3 to act as a helpful neighbor for a restarting router. Include the planned-only keyword to indicate that OSPFv3 should only help a restarting router performing a planned restart. nsf [ietf] [planned-only] Enable a graceful restart of OSPFv3. • ietf — This keyword is used to distinguish the IETF standard implementation of graceful restart from other implementations. Since the IETF implementation is the only one supported, this keyword is optional. • planned-only — This keyword indicates that OSPF should only perform a graceful restart when the restart is planned (i.e., when the restart is a result of the initiate failover command). 996 Configuring OSPF and OSPFv3 OSPF Configuration Examples This section contains the following examples: • Configuring an OSPF Border Router and Setting Interface Costs • Configuring Stub and NSSA Areas for OSPF and OSPFv3 • Configuring a Virtual Link for OSPF and OSPFv3 Configuring an OSPF Border Router and Setting Interface Costs This example shows how to configure the PowerConnect switch as an OSPF border router. The commands in this example configure the areas and interfaces on Border Router A shown in Figure 34-35. Figure 34-35. OSPF Area Border Router Area 0 Backbone Area Internal Router VLAN 50 192.150.2.1 Border Router A VLAN 80 192.150.3.1 VLAN 70 192.150.2.2 Border Router B VLAN 90 192.150.4.1 Area 2 Area 3 Configuring OSPF and OSPFv3 997 To Configure Border Router A: 1 Enable routing on the switch. console#configure console(config)#ip routing 2 Create VLANS 70, 80, and 90. console(config)#vlan 70,80,90 3 Assign IP addresses for VLANs 70, 80 and 90. console(config)#interface vlan 70 console(config-if-vlan70)#ip address 192.150.2.2 255.255.255.0 console(config-if-vlan70)#exit console(config)#interface vlan 80 console(config-if-vlan80)#ip address 192.150.3.1 255.255.255.0 console(config-if-vlan80)#exit console(config)#interface vlan 90 console(config-if-vlan90)#ip address 192.150.4.1 255.255.255.0 console(config-if-vlan90)#exit 4 Enable OSPF on the switch and specify a router ID. console(config)#router ospf console(config-router)#router-id 192.150.9.9 console(config-router)#exit 998 Configuring OSPF and OSPFv3 5 Configure the OSPF area ID, priority, and cost for each interface. NOTE: OSPF is globally enabled by default. To make it operational on the router, you configure OSPF for particular interfaces and identify which area the interface is associated with. console(config)#interface vlan 70 console(config-if-vlan70)#ip ospf area 0.0.0.0 console(config-if-vlan70)#ip ospf priority 128 console(config-if-vlan70)#ip ospf cost 32 console(config-if-vlan70)#exit console(config)#interface vlan 80 console(config-if-vlan80)#ip ospf area 0.0.0.2 console(config-if-vlan80)#ip ospf priority 255 console(config-if-vlan80)#ip ospf cost 64 console(config-if-vlan80)#exit console(config)#interface vlan 90 console(config-if-vlan90)#ip ospf area 0.0.0.2 console(config-if-vlan90)#ip ospf priority 255 console(config-if-vlan90)#ip ospf cost 64 console(config-if-vlan90)#exit Configuring OSPF and OSPFv3 999 Configuring Stub and NSSA Areas for OSPF and OSPFv3 In this example, Area 0 connects directly to two other areas: Area 1 is defined as a stub area and Area 2 is defined as an NSSA area. NOTE: OSPFv2 and OSPFv3 can operate concurrently on a network and on the same interfaces (although they do not interact). This example configures both protocols simultaneously. Figure 34-36 illustrates this example OSPF configuration. Figure 34-36. 1000 OSPF Configuration—Stub Area and NSSA Area Configuring OSPF and OSPFv3 Switch A is a backbone router. It links to an ASBR (not defined here) that routes traffic outside the AS. To configure Switch A: 1 Globally enable IPv6 and IPv4 routing: console#configure console(config)#ipv6 unicast-routing console(config)#ip routing 2 Create VLANs 6 and 12. console(config)#vlan 6,12 3 Configure IP and IPv6 addresses on VLAN routing interface 6. console(config-if)#interface vlan 6 console(config-if-vlan6)#ip address 10.2.3.3 255.255.255.0 console(config-if-vlan6)#ipv6 address 3000:2:3::/64 eui64 4 Associate the interface with area 0.0.0.0 and enable OSPFv3. console(config-if-vlan6)#ip ospf area 0.0.0.0 console(config-if-vlan6)#ipv6 ospf console(config-if-vlan6)#exit 5 Configure IP and IPv6 addresses on VLAN routing interface 12. console(config)#interface vlan 12 console(config-if-vlan12)#ip address 10.3.100.3 255.255.255.0 console(config-if-vlan12)#ipv6 address 3000:3:100::/64 eui64 6 Associate the interface with area 0.0.0.0 and enable OSPFv3. console(config-if-vlan12)#ip ospf area 0.0.0.0 console(config-if-vlan12)#ipv6 ospf console(config-if-vlan12)#exit 7 Define the OSPF and OSPFv3 router IDs for the switch: console(config)#ipv6 router ospf console(config-rtr)#router-id 3.3.3.3 console(config-rtr)#exit Configuring OSPF and OSPFv3 1001 console(config)#router ospf console(config-router)#router-id 3.3.3.3 console(config-router)#exit Switch B is a ABR that connects Area 0 to Areas 1 and 2. To configure Switch B: 1 Configure IPv6 and IPv4 routing. The static routes are included for illustration only: Redistributed static routes, like routes distributed from other protocols, are not injected into stub areas such as Area 1: console#configure console(config)#ipv6 unicast-routing console(config)#ipv6 route 3000:44:44::/64 3000:2:3::210:18ff:fe82:c14 console(config)#ip route 10.23.67.0 255.255.255.0 10.2.3.3 2 Create VLANs 5, 10, and 17. console(config)#vlan 5,10,17 3 On VLANs 5, 10, and 17, configure IPv4 and IPv6 addresses and enable OSPFv3. For IPv6, associate VLAN 5 with Area 0, VLAN 10 with Area 1, and VLAN 17 with Area 2. console(config)#interface vlan 5 console(config-if-vlan5)#ip address 10.2.3.2 255.255.255.0 console(config-if-vlan5)#ipv6 address 3000:2:3::/64 eui64 console(config-if-vlan5)#ipv6 ospf console(config-if-vlan5)#ipv6 ospf areaid 0 console(config-if-vlan5)#exit console(config)#interface vlan 10 console(config-if-vlan10)#ip address 10.1.2.2 255.255.255.0 console(config-if-vlan10)#ipv6 address 3000:1:2::/64 eui64 console(config-if-vlan10)#ipv6 ospf console(config-if-vlan10)#ipv6 ospf areaid 1 console(config-if-vlan10)#exit 1002 Configuring OSPF and OSPFv3 console(config)#interface vlan 17 console(config-if-vlan17)#ip address 10.2.4.2 255.255.255.0 console(config-if-vlan17)#ipv6 address 3000:2:4::/64 eui64 console(config-if-vlan17)#ipv6 ospf console(config-if-vlan17)#ipv6 ospf areaid 2 console(config-if-vlan17)#exit 4 For IPv4: Configure the router ID, define an OSPF router, and define Area 1 as a stub., and define Area 2 as an NSSA. console(config)#router ospf console(config-router)#router-id 2.2.2.2 console(config-router)#area 0.0.0.1 stub console(config-router)#area 0.0.0.2 nssa 5 For IPv4: Enable OSPF for IPv4 on VLANs 10, 5, and 17 by globally defining the range of IP addresses associated with each interface, and then associating those ranges with Areas 1, 0, and 2, respectively. console(config-router)#network 10.1.2.0 0.0.0.255 area 0.0.0.1 console(config-router)#network 10.2.3.0 0.0.0.255 area 0.0.0.0 console(config-router)#network 10.2.4.0 0.0.0.255 area 0.0.0.2 6 For IPv4: Configure a metric cost to associate with static routes when they are redistributed via OSPF: console(config-router)#redistribute static metric 1 subnets console(config-router)#exit 7 For IPv6: Define an OSPF router. Define Area 1 as a stub and area 2 as a Not-So-Stubby-Area (NSSA). Configure a metric cost to associate with static routes when they are redistributed via OSPF: console(config)#ipv6 router ospf console(config-rtr)#router-id 2.2.2.2 console(config-rtr)#area 0.0.0.1 stub console(config-rtr)#area 0.0.0.2 nssa Configuring OSPF and OSPFv3 1003 console(config-rtr)#redistribute static metric 105 metric-type 1 console(config-rtr)#exit Configuring a Virtual Link for OSPF and OSPFv3 In this example, Area 0 connects directly to Area 1. A virtual link is defined that traverses Area 1 and connects to Area 2. This example assumes other OSPF settings, such as area and interface configuration, have already been configured. Figure 34-37 illustrates the relevant components in this example OSPF configuration. Figure 34-37. OSPF Configuration—Virtual Link Switch B is an ABR that directly connects Area 0 to Area 1. Note that in the previous example, Switch B connected to a stub area and an NSSA. Virtual links cannot be created across stub areas or NSSAs. 1004 Configuring OSPF and OSPFv3 The following commands define a virtual link that traverses Area 1 to Switch C (5.5.5.5). To configure Switch B: 1 Configure the virtual link to Switch C for IPv4. console#configure console(config)#router ospf console(config-router)#area 0.0.0.1 virtual-link 5.5.5.5 console(config-router)#exit 2 Configure the virtual link to Switch C for IPv6. console#configure console(config)#ipv6 router ospf console(config-rtr)#area 0.0.0.1 virtual-link 5.5.5.5 console(config-rtr)#exit Switch C is a ABR that enables a virtual link from the remote Area 2 in the AS to Area 0. The following commands define a virtual link that traverses Area 1 to Switch B (2.2.2.2). To configure Switch C: 1 For IPv4, assign the router ID, create the virtual link to Switch B, and associate the VLAN routing interfaces with the appropriate areas. console(config)#router ospf console(config-router)#area 0.0.0.1 virtual-link 2.2.2.2 console(config-router)#exit 2 For IPv6, assign the router ID and create the virtual link to Switch B. console(config)#ipv6 router ospf console(config-rtr)#area 0.0.0.1 virtual-link 2.2.2.2 console(config-rtr)#exit Configuring OSPF and OSPFv3 1005 Interconnecting an IPv4 Backbone and Local IPv6 Network In Figure 34-38, two PowerConnect L3 switches are connected as shown in the diagram. The VLAN 15 routing interface on both switches connects to an IPv4 backbone network where OSPF is used as the dynamic routing protocol to exchange IPv4 routes. OSPF allows device 1 and device 2 to learn routes to each other (from the 20.20.20.x network to the 10.10.10.x network and vice versa). The VLAN 2 routing interface on both devices connects to the local IPv6 network. OSPFv3 is used to exchange IPv6 routes between the two devices. The tunnel interface allows data to be transported between the two remote IPv6 networks over the IPv4 network. Figure 34-38. IPv4 and IPv6 Interconnection Example To configure Switch A: 1 Create the VLANs. console(config)#vlan 2,15 2 Enable IPv4 and IPv6 routing on the switch. console(config)#ip routing console(config)#ipv6 unicast-routing 3 Set the OSPF router ID. console(config)#router ospf console(config-router)#router-id 1.1.1.1 console(config-router)#exit 4 Set the OSPFv3 router ID. console(config)#ipv6 router ospf console(config-rtr)#router-id 1.1.1.1 1006 Configuring OSPF and OSPFv3 console(config-rtr)#exit 5 Configure the IPv4 address and OSPF area for VLAN 15. console(config)#interface vlan 15 console(config-if-vlan15)#ip address 20.20.20.1 255.255.255.0 console(config-if-vlan15)#ip ospf area 0.0.0.0 console(config-if-vlan15)#exit 6 Configure the IPv6 address and OSPFv3 information for VLAN 2. console(config)#interface vlan 2 console(config-if-vlan2)#ipv6 address 2020:1::1/64 console(config-if-vlan2)#ipv6 ospf console(config-if-vlan2)#ipv6 ospf network point-to-point console(config-if-vlan2)#exit 7 Configure the tunnel. console(config)#interface tunnel 0 console(config-if-tunnel0)#ipv6 address 2001::1/64 console(config-if-tunnel0)#tunnel mode ipv6ip console(config-if-tunnel0)#tunnel source 20.20.20.1 console(config-if-tunnel0)#tunnel destination 10.10.10.1 console(config-if-tunnel0)#ipv6 ospf console(config-if-tunnel0)#ipv6 ospf network point-to-point console(config-if-tunnel0)#exit 8 Configure the loopback interface. The switch uses the loopback IP address as the OSPF and OSPFv3 router ID. console(config)#interface loopback 0 console(config-if-loopback0)#ip address 1.1.1.1 255.255.255.0 console(config-if-loopback0)#exit console(config)#exit Configuring OSPF and OSPFv3 1007 To configure Switch B: 1 Create the VLANs. console(config)#vlan 2,15 2 Enable IPv4 and IPv6 routing on the switch. console(config)#ip routing console(config)#ipv6 unicast-routing 3 Set the OSPF router ID. console(config)#router ospf console(config-router)#router-id 2.2.2.2 console(config-router)#exit 4 Set the OSPFv3 router ID. console(config)#ipv6 router ospf console(config-rtr)#router-id 2.2.2.2 console(config-rtr)#exit 5 Configure the IPv4 address and OSPF area for VLAN 15. console(config)#interface vlan 15 console(config-if-vlan15)#ip address 10.10.10.1 255.255.255.0 console(config-if-vlan15)#ip ospf area 0.0.0.0 console(config-if-vlan15)#exit 6 Configure the IPv6 address and OSPFv3 information for VLAN 2. console(config)#interface vlan 2 console(config-if-vlan2)#ipv6 address 2020:2::2/64 console(config-if-vlan2)#ipv6 ospf console(config-if-vlan2)#ipv6 ospf network point-to-point console(config-if-vlan2)#exit 7 Configure the tunnel. console(config)#interface tunnel 0 console(config-if-tunnel0)#ipv6 address 2001::2/64 console(config-if-tunnel0)#tunnel mode ipv6ip console(config-if-tunnel0)#tunnel source 10.10.10.1 console(config-if-tunnel0)#tunnel destination 20.20.20.1 console(config-if-tunnel0)#ipv6 ospf console(config-if-tunnel0)#ipv6 ospf network point-to-point console(config-if-tunnel0)#exit 8 Configure the loopback interface. The switch uses the loopback IP address as the OSPF and OSPFv3 router ID. console(config)#interface loopback 0 console(config-if-loopback0)#ip address 2.2.2.2 255.255.255.0 1008 Configuring OSPF and OSPFv3 console(config-if-loopback0)#exit console(config)#exit Configuring the Static Area Range Cost Figure 34-39 shows a topology for the configuration that follows. Figure 34-39. Static Area Range Cost Example Topology R3 Area 0 VLAN 103 ABR R0 VLAN 101 R1 VLAN 102 VLAN 104 R2 Area 1 1 Configure R0. terminal length 0 config hostname ABR-R0 line console exec-timeout 0 exit vlan 101-103 exit ip routing router ospf router-id 10.10.10.10 network 172.20.0.0 0.0.255.255 area 0 network 172.21.0.0 0.0.255.255 area 1 area 1 range 172.21.0.0 255.255.0.0 summarylink timers spf 3 5 exit Configuring OSPF and OSPFv3 1009 interface vlan 101 ip address 172.21.1.10 255.255.255.0 ip ospf hello-interval 1 ip ospf dead-interval 4 ip ospf network point-to-point exit interface te1/0/21 switchport mode trunk description “R1” exit interface vlan 102 ip address 172.21.2.10 255.255.255.0 ip ospf hello-interval 1 ip ospf dead-interval 4 ip ospf network point-to-point exit interface te1/0/22 description “R2” switchport mode trunk exit interface vlan 103 ip address 172.20.1.10 255.255.255.0 ip ospf hello-interval 1 ip ospf dead-interval 4 ip ospf network point-to-point exit interface te1/0/23 switchport mode trunk description “R3” exit exit 2 Configure R1. terminal length 0 config hostname R1 line console exec-timeout 0 exit vlan 101,104 exit ip routing router ospf router-id 1.1.1.1 network 172.21.0.0 0.0.255.255 area 1 timers spf 3 5 1010 Configuring OSPF and OSPFv3 exit interface vlan 101 ip address 172.21.1.1 255.255.255.0 routing ip ospf hello-interval 1 ip ospf dead-interval 4 ip ospf network point-to-point exit interface te1/0/21 switchport mode trunk exit interface vlan 104 ip address 172.21.3.1 255.255.255.0 routing ip ospf hello-interval 1 ip ospf dead-interval 4 ip ospf network point-to-point exit interface te1/0/22 switchport mode trunk exit interface loopback 0 ip address 172.21.254.1 255.255.255.255 exit exit 3 Configure R2. terminal length 0 config line console serial timeout 0 exit ip routing router ospf router-id 2.2.2.2 network 172.21.0.0 0.0.255.255 area 1 timers spf 3 5 exit vlan 102,104 exit interface vlan 102 ip address 172.21.2.2 255.255.255.0 routing ip ospf hello-interval 1 ip ospf dead-interval 4 ip ospf network point-to-point Configuring OSPF and OSPFv3 1011 exit interface te1/0/21 switchport mode trunk exit interface vlan 104 ip address 172.21.3.2 255.255.255.0 routing ip ospf hello-interval 1 ip ospf dead-interval 4 ip ospf network point-to-point exit interface te1/0/22 switchport mode trunk exit interface loopback 0 ip address 172.21.254.2 255.255.255.255 exit exit 4 R3 config: terminal length 0 config line console serial timeout 0 exit ip routing router ospf router-id 3.3.3.3 network 172.21.0.0 0.0.255.255 area 0 timers spf 3 5 exit vlan 103 exit interface vlan 103 ip address 172.21.1.1 255.255.255.0 routing ip ospf hello-interval 1 ip ospf dead-interval 4 ip ospf network point-to-point exit interface te1/0/21 switchport mode trunk exit interface loopback 0 ip address 172.21.254.2 255.255.255.255 exit 1012 Configuring OSPF and OSPFv3 exit Discussion With no area range cost specified, the range uses auto cost: (ABR-R0) #show ip ospf range 1 Prefix 172.21.0.0 Subnet Mask 255.255.0.0 Type S Action Advertise Cost Auto Active Y (ABR-R0) #show ip ospf database summary Network Summary States (Area 0.0.0.0) LS Age: 644 LS options: (E-Bit) LS Type: Network Summary LSA LS Id: 172.21.0.0 (network prefix) Advertising Router: 10.10.10.10 LS Seq Number: 0x80000002 Checksum: 0x8ee1 Length: 28 Network Mask: 255.255.0.0 Metric: 2 Min—The cost can be set to 0, the minimum value. OSPF re-advertises the summary LSA with a metric of 0: (ABR-R0) (config-router)#area 1 range 172.21.0.0 255.255.0.0 summarylink advertise cost ? <0-16777215> Set area range cost (ABR-R0) (config-router)#area 1 range 172.21.0.0 255.255.0.0 summarylink advertise cost 0 (ABR-R0) #show ip ospf range 1 Prefix 172.21.0.0 Subnet Mask 255.255.0.0 Type S Action Advertise Cost 0 Active Y (ABR-R0) #show ip ospf 0 database summary Network Summary States (Area 0.0.0.0) LS Age: 49 LS options: (E-Bit) LS Type: Network Summary LSA LS Id: 172.21.0.0 (network prefix) Advertising Router: 10.10.10.10 Configuring OSPF and OSPFv3 1013 LS Seq Number: 0x80000003 Checksum: 0x78f8 Length: 28 Network Mask: 255.255.0.0 Metric: 0 The cost can be set to the maximum value, 16,777,215, which is LSInfinity. Since OSPF cannot send a type 3 summary LSA with this metric (according to RFC 2328), the summary LSA is flushed. The individual routes are not readvertised. Configuring Flood Blocking Figure 34-40 shows an example topology for flood blocking. The configuration follows. Figure 34-40. Flood Blocking Topology R3 VLAN 103 R0 VLAN 101 R1 VLAN 102 VLAN 104 1 Configure R0: terminal length 0 config hostname R0 line console exec-timeout 0 exit vlan 101-103 exit ip routing 1014 Configuring OSPF and OSPFv3 R2 router ospf router-id 10.10.10.10 network 172.20.0.0 0.0.255.255 area 0 network 172.21.0.0 0.0.255.255 area 0 timers spf 3 5 exit interface vlan 101 ip address 172.21.1.10 255.255.255.0 ip ospf hello-interval 1 ip ospf dead-interval 4 ip ospf network point-to-point exit interface te1/0/21 switchport mode trunk description “R1” exit interface vlan 102 ip address 172.21.2.10 255.255.255.0 ip ospf hello-interval 1 ip ospf dead-interval 4 ip ospf network point-to-point exit interface te1/0/22 description “R2” switchport mode trunk exit interface vlan 103 ip address 172.20.1.10 255.255.255.0 ip ospf hello-interval 1 ip ospf dead-interval 4 ip ospf network point-to-point exit interface te1/0/23 switchport mode trunk description “R3” exit exit 2 Configure R1: terminal length 0 config hostname R1 line console exec-timeout 0 exit Configuring OSPF and OSPFv3 1015 vlan 101,104 exit ip routing router ospf router-id 1.1.1.1 network 172.21.0.0 0.0.255.255 area 0 timers spf 3 5 exit interface vlan 101 ip address 172.21.1.1 255.255.255.0 routing ip ospf hello-interval 1 ip ospf dead-interval 4 ip ospf network point-to-point exit interface te1/0/21 switchport mode trunk exit interface vlan 104 ip address 172.21.3.1 255.255.255.0 routing ip ospf hello-interval 1 ip ospf dead-interval 4 ip ospf network point-to-point exit interface te1/0/22 switchport mode trunk exit interface loopback 0 ip address 172.21.254.1 255.255.255.255 exit exit 3 Configure R2: terminal length 0 config line console serial timeout 0 exit ip routing router ospf router-id 2.2.2.2 network 172.21.0.0 0.0.255.255 area 0 timers spf 3 5 exit 1016 Configuring OSPF and OSPFv3 vlan 102,104 exit interface vlan 102 ip address 172.21.2.2 255.255.255.0 routing ip ospf hello-interval 1 ip ospf dead-interval 4 ip ospf network point-to-point exit interface te1/0/21 switchport mode trunk exit interface vlan 104 ip address 172.21.3.2 255.255.255.0 routing ip ospf hello-interval 1 ip ospf dead-interval 4 ip ospf network point-to-point exit interface te1/0/22 switchport mode trunk exit interface loopback 0 ip address 172.21.254.2 255.255.255.255 exit exit 4 Configure R3: terminal length 0 config line console serial timeout 0 exit ip routing router ospf router-id 3.3.3.3 network 172.21.0.0 0.0.255.255 area 0 timers spf 3 5 exit vlan 103 exit interface vlan 103 ip address 172.21.1.1 255.255.255.0 routing ip ospf hello-interval 1 Configuring OSPF and OSPFv3 1017 ip ospf dead-interval 4 ip ospf network point-to-point exit interface te1/0/21 switchport mode trunk exit interface loopback 0 ip address 172.21.254.2 255.255.255.255 exit exit Discussion With flood blocking disabled on all interfaces, sending a T3 summary LSA from R3 to R0 will cause R0 to forward the LSA on its interface to R1. Enabling flood blocking on R0's interface to R1 will inhibit this behavior. (R0)(config-if-vlan101)ip ospf database-filter all out A trace on the R3-R0 link shows that the LSA is actually flooded from R1 to R0, since R1 received the LSA via R2. Even though R1 does not receive this LSA directly from R0, it still correctly computes the route through the R0: (R1) #show ip route Route Codes: R - RIP Derived, O - OSPF Derived, C - Connected, S - Static B - BGP Derived, IA - OSPF Inter Area E1 - OSPF External Type 1, E2 - OSPF External Type 2 N1 - OSPF NSSA External Type 1, N2 - OSPF NSSA External Type 2 O IA 100.0.0.0/24 [110/2] via 172.21.1.10, 00h:01m:35s, 0/25 OSPF also blocks external LSAs on the blocked interface. Stopping and restarting R3's OSPF protocol causes R3 to re-originate its router LSA. R0 does not send R3's router LSA on the blocked interface. With flood blocking enabled on the R0 interface, if the link from R0 to R1 bounces, R0 Database Description packets do not include any LSAs. However, database synchronization still occurs (through R2) and R1 computes the correct routes after the link is restored. 1018 Configuring OSPF and OSPFv3 Configuring RIP 35 This chapter describes how to configure Routing Information Protocol (RIP) on the switch. RIP is a dynamic routing protocol for IPv4 networks. The topics covered in this chapter include: • RIP Overview • Default RIP Values • Configuring RIP Features (Web) • Configuring RIP Features (CLI) • RIP Configuration Example RIP Overview RIP is an Interior Gateway Protocol (IGP) that performs dynamic routing within a network. PowerConnect 7000 Series switches support two dynamic routing protocols: OSPF and Routing Information Protocol (RIP). Unlike OSPF, RIP is a distance-vector protocol and uses UDP broadcasts to maintain topology information and hop counts to determine the best route to transmit IP traffic. RIP is best suited for small, homogenous networks. How Does RIP Determine Route Information? The routing information is propagated in RIP update packets that are sent out both periodically and in the event of a network topology change. On receipt of a RIP update, depending on whether the specified route exists or does not exist in the route table, the router may modify, delete or add the route to its route table. RIP uses hop count, which is the number of routers an IP packet must pass through, to calculate the best route for a packet. A route with a low hop count is preferred over a route with a higher hop count. A directly-connected route has a hop-count of 0. With RIP, the maximum number of hops from source to destination is 15. Packets with a hop count greater than 15 are dropped because the destination network is considered unreachable. Configuring RIP 1019 What Is Split Horizon? RIP uses a technique called split horizon to avoid problems caused by including routes in updates sent to the router from which the route was originally learned. With simple split horizon, a route is not included in updates sent on the interface on which it was learned. In split horizon with poison reverse, a route is included in updates sent on the interface where it was learned, but the metric is set to infinity. What RIP Versions Are Supported? There are two versions of RIP: • • RIP-1 defined in RFC 1058 – Routes are specified by IP destination network and hop count – The routing table is broadcast to all stations on the attached network RIP-2 defined in RFC 1723 – Route specification is extended to include subnet mask and gateway – The routing table is sent to a multicast address, reducing network traffic – An authentication method is used for security The PowerConnect 7000 Series switches support both versions of RIP. You may configure a given port: • To receive packets in either or both formats • To transmit packets formatted for RIP-1 or RIP-2 or to send RIP-2 packets to the RIP-1 broadcast address • To prevent any RIP packets from being received • To prevent any RIP packets from being transmitted 1020 Configuring RIP Default RIP Values RIP is globally enabled by default. To make it operational on the router, you configure and enable RIP for particular VLAN routing interfaces. Table 35-1 shows the global default values for RIP. Table 35-1. RIP Global Defaults Parameter Default Value Admin Mode Enabled Split Horizon Mode Simple Auto Summary Mode Disabled Host Routes Accept Mode Enabled Default Information Originate Disabled Default Metric None configured Route Redistribution Disabled for all sources. Table 35-2 shows the per-interface default values for RIP. Table 35-2. RIP Per-Interface Defaults Parameter Default Value Admin Mode Disabled Send Version RIPv2 Receive Version Both Authentication Type None Configuring RIP 1021 Configuring RIP Features (Web) This section provides information about the OpenManage Switch Administrator pages for configuring and monitoring RIP features on a PowerConnect 7000 Series switch. For details about the fields on a page, click at the top of the page. RIP Configuration Use the Configuration page to enable and configure or disable RIP in Global mode. To display the page, click Routing → RIP → Configuration in the navigation panel. Figure 35-1. RIP Configuration 1022 Configuring RIP RIP Interface Configuration Use the Interface Configuration page to enable and configure or to disable RIP on a specific interface. To display the page, click Routing → RIP → Interface Configuration in the navigation panel. Figure 35-2. RIP Interface Configuration Configuring RIP 1023 RIP Interface Summary Use the Interface Summary page to display RIP configuration status on an interface. To display the page, click Routing → RIP → Interface Summary in the navigation panel. Figure 35-3. RIP Interface Summary 1024 Configuring RIP RIP Route Redistribution Configuration Use the Route Redistribution Configuration page to configure the RIP Route Redistribution parameters. The allowable values for each fields are displayed next to the field. If any invalid values are entered, an alert message is displayed with the list of all the valid values. To display the page, click Routing → RIP → Route Redistribution Configuration in the navigation panel. Figure 35-4. RIP Route Redistribution Configuration NOTE: Static reject routes are not redistributed by RIP. For a static reject route, the next hop interface value is Null0. Packets to the network address specified in static reject routes are intentionally dropped. Configuring RIP 1025 RIP Route Redistribution Summary Use the Route Redistribution Summary page to display Route Redistribution configurations. To display the page, click Routing → RIP → Route Redistribution Summary in the navigation panel. Figure 35-5. RIP Route Redistribution Summary 1026 Configuring RIP Configuring RIP Features (CLI) This section provides information about the commands you use to configure RIP settings on the switch. For more information about the commands, see the PowerConnect 7000 Series CLI Reference Guide at support.dell.com/manuals. Configuring Global RIP Settings Beginning in Privileged EXEC mode, use the following commands to configure various global RIP settings for the switch. NOTE: RIP is enabled by default. The Global RIP Settings are optional. Command Purpose configure Enter global configuration mode. router rip Enter OSPF configuration mode. split-horizon {none | Set the RIP split horizon mode. simple | poison} • none — RIP does not use split horizon to avoid routing loops. • simple — RIP uses split horizon to avoid routing loops. • poison — RIP uses split horizon with poison reverse (increases routing packet update size). auto-summary Enable the RIP auto-summarization mode. no hostroutesaccept Prevent the switch from accepting host routes. default-information originate Control the advertisement of default routes. default-metric metric- Set a default for the metric of distributed routes. value The metric-value variable is the metric (or preference) value of the default route. (Range: 1–15) enable Reset the default administrative mode of RIP in the router (active) CTRL + Z Exit to Privileged EXEC mode. show ip rip View various RIP settings for the switch. Configuring RIP 1027 Configuring RIP Interface Settings Beginning in Privileged EXEC mode, use the following commands to configure per-interface RIP settings. Command Purpose configure Enter global configuration mode. interface vlan vlan-id Enter Interface Configuration mode for the specified VLAN. ip rip Enable RIP on the interface. ip rip send version {rip1 Configure the interface to allow RIP control packets of the rip1c | rip2 |none} specified version(s) to be sent. ip rip receive version {rip1 | rip2 | both | none} Configure the interface to allow RIP control packets of the specified version(s) to be received. ip rip authentication {none | {simple key} | {encrypt key key-id} set the RIP Version 2 Authentication Type and Key for the interface. • key — Authentication key for the specified interface. (Range: 16 bytes or less) • encrypt — Specifies the Ethernet unit/port of the interface to view information. • key-id — Authentication key identifier for authentication type encrypt. (Range: 0-255) exit Exit to Global Configuration Mode exit Exit to Privileged Exec mode. show ip rip interface vlan View RIP configuration information for the specified routing interface. vlan-id show ip rip interface brief 1028 Configuring RIP View summary information about the RIP configuration on all interfaces. Configuring Route Redistribution Settings Beginning in Privileged EXEC mode, use the following commands to configure an OSPF area range and to configure route redistribution settings. Command Purpose configure Enter global configuration mode. router rip Enter RIP configuration mode. distribute-list Specify the access list to filter routes received from the static | connected} switch. For information about the commands you use to configure ACLs, see "Configuring ACLs (CLI)" on page 543. accesslistname out {ospf | source protocol. The ACL must already exist on the • accesslistname — The name used to identify an existing ACL. • ospf — Apply the specified access list when OSPF is the source protocol. • static — Apply the specified access list when packets come through the static route. • connected — Apply the specified access list when packets come from a directly connected route. redistribute {static | connected} [metric integer] Configure RIP to allow redistribution of routes from the specified source protocol/routers. • static — Specifies that the source is a static route. • connected — Specifies that the source is a directly connected route. • metric — Specifies the metric to use when redistributing the route. Range: 1-15. Configuring RIP 1029 Command Purpose redistribute ospf [metric Configure RIP to allow redistribution of routes from the metric] [match [internal] OSPF. [external 1] [external 2] • ospf— Specifies OSPF as the source protocol. [nssa-external 1] [nssa• metric — Specifies the metric to use when external 2]] redistributing the route. Range: 1-15. • internal — Adds internal matches to any match types presently being redistributed. • external 1 — Adds routes imported into OSPF as Type1 external routes into any match types presently being redistributed. • external 2 — Adds routes imported into OSPF as Type2 external routes into any match types presently being redistributed. • nssa-external 1 — Adds routes imported into OSPF as NSSA Type-1 external routes into any match types presently being redistributed. • nssa-external 2 — Adds routes imported into OSPF as NSSA Type-2 external routes into any match types presently being redistributed. distance rip integer Set the route preference value of RIP in the router. Lower route preference values are preferred when determining the best route. exit Exit to Global Config mode. exit Exit to Privileged Exec mode. show ip rip View information about the RIP route distribution configuration. 1030 Configuring RIP RIP Configuration Example This example includes four PowerConnect switches that use RIP to determine network topology and route information. The commands in this example configure Switch A shown in Figure 35-6. Figure 35-6. RIP Network Diagram To configure the switch: 1 Enable routing on the switch console#config console(config)#ip routing 2 Create VLANs 10, 20, and 30. console(config)#vlan 10,20,30 3 Assign an IP address and enable RIP on each interface. Additionally, the commands specify that each interface can receive both RIP-1 and RIP-2 frames but send only RIP-2 formatted frames. console(config)#interface vlan 10 console(config-if-vlan10)#ip address 192.168.10.1 255.255.255.0 console(config-if-vlan10)#ip rip console(config-if-vlan10)#ip rip receive version both console(config-if-vlan10)#ip rip send version rip2 console(config-if-vlan10)#exit Configuring RIP 1031 console(config)#interface vlan 20 console(config-if-vlan20)#ip address 192.168.20.1 255.255.255.0 console(config-if-vlan20)#ip rip console(config-if-vlan20)#ip rip receive version both console(config-if-vlan20)#ip rip send version rip2 console(config-if-vlan20)#exit console(config)#interface vlan 30 console(config-if-vlan30)#ip address 192.168.30.1 255.255.255.0 console(config-if-vlan30)#ip rip console(config-if-vlan30)#ip rip receive version both console(config-if-vlan30)#ip rip send version rip2 console(config-if-vlan30)#exit 4 Enable auto summarization of subprefixes when crossing classful boundaries. console(config)#router rip console(config-router)#auto-summary console(config-router)#exit console(config)#exit 5 Verify the configuration console#show ip rip RIP Admin Mode.......................... Split Horizon Mode...................... Auto Summary Mode....................... Host Routes Accept Mode................. Global route changes.................... Global queries.......................... Enable Simple Enable Enable 0 0 Default Metric.................... Not configured Default Route Advertise........... 0 console#show ip rip interface brief 1032 Interface IP Address ---------Vl1 Vl10 Vl20 Vl30 -----------0.0.0.0 192.168.10.1 192.168.10.1 192.168.10.1 Configuring RIP Send Version --------RIP-2 RIP-2 RIP-2 RIP-2 Receive Version ------RIP-2 Both Both Both RIP Mode -------Disable Enable Enable Disable Link State -----Down Down Down Down Configuring VRRP 36 This chapter describes how to configure Virtual Routing Redundancy Protocol (VRRP) on the switch. VRRP can help create redundancy on networks in which end-stations are statically configured with the default gateway IP address. The topics covered in this chapter include: • VRRP Overview • Default VRRP Values • Configuring VRRP Features (Web) • Configuring VRRP Features (CLI) • VRRP Configuration Example VRRP Overview The Virtual Router Redundancy (VRRP) protocol is designed to handle default router (L3 switch) failures by providing a scheme to dynamically elect a backup router. VRRP can help minimize black hole periods due to the failure of the default gateway router during which all traffic directed towards it is lost until the failure is detected. How Does VRRP Work? VRRP eliminates the single point of failure associated with static default routes by enabling a backup router to take over from a master router without affecting the end stations using the route. The end stations will use a virtual IP address that will be recognized by the backup router if the master router fails. Participating routers use an election protocol to determine which router is the master router at any given time. A maximum of 50 virtual routers may be configured. A given port may appear as more than one virtual router to the network, also, more than one port on a switch may be configured as a virtual router. Either a physical port or a routed VLAN may participate. Configuring VRRP 1033 With VRRP, a virtual router is associated with one or more IP addresses that serve as default gateways. In the event that the VRRP router controlling these IP addresses (formally known as the master) fails, the group of IP addresses and the default forwarding role is taken over by a Backup VRRP router. NOTE: It is not possible to ping the VRRP IP address from the VRRP master. Use the show vrrp command to display the status of the VRRP router What Is the VRRP Router Priority? The VRRP router priority is a value from 1–255 that determines which router is the master. The greater the number, the higher the priority. If the virtual IP address is the IP address of a VLAN routing interface on one of the routers in the VRRP group, the router with IP address that is the same as the virtual IP address is the interface owner and automatically has a priority of 255. By default, this router is the VRRP master in the group. If no router in the group owns the VRRP virtual IP address, the router with the highest configured priority is the VRRP master. If multiple routers have the same priority, the router with the highest IP address becomes the VRRP master. If the VRRP master fails, other members of the VRRP group will elect a master based on the configured router priority values. For example, router A is the interface owner and master, and it has a priority of 255. Router B is configured with a priority of 200, and Router C is configured with a priority of 190. If Router A fails, Router B assumes the role of VRRP master because it has a higher priority. What Is VRRP Preemption? If preempt mode is enabled and a router with a higher priority joins the VRRP group, it takes over the VRRP master role if the current VRRP master is not the owner of the virtual IP address. The preemption delay controls how long to wait to determine whether a higher priority Backup router preempts a lower priority master. In certain cases, for example, during periods of network congestion, a backup router might fail to receive advertisements from the master. This could cause members in the VRRP group to change their states frequently, i.e. flap. The problem can be resolved by setting the VRRP preemption delay timer to a non-zero value. 1034 Configuring VRRP What Is VRRP Accept Mode? The accept mode allows the switch to respond to pings (ICMP Echo Requests) sent to the VRRP virtual IP address. The VRRP specification (RFC 3768) indicates that a router may accept IP packets sent to the virtual router IP address only if the router is the address owner. In practice, this restriction makes it more difficult to troubleshoot network connectivity problems. When a host cannot communicate, it is common to ping the host's default gateway to determine whether the problem is in the first hop of the path to the destination. When the default gateway is a virtual router that does not respond to pings, this troubleshooting technique is unavailable. In the PowerConnect switch VRRP feature, you can enable Accept Mode to allow the system to respond to pings that are sent to the virtual IP address. This capability adds support for responding to pings, but does not allow the VRRP master to accept other types of packets. The VRRP master responds to both fragmented and un-fragmented ICMP Echo Request packets. The VRRP master responds to Echo Requests sent to the virtual router's primary address or any of its secondary addresses. Members of the virtual router who are in backup state discard ping packets destined to VRRP addresses, just as they discard any Ethernet frame sent to a VRRP MAC address. When the VRRP master responds with an Echo Reply, the source IPv4 address is the VRRP address and source MAC address is the virtual router's MAC address. What Are VRRP Route and Interface Tracking? The VRRP Route/Interface Tracking feature extends VRRP capability to allow tracking of specific routes and interface IP states within the router that can alter the priority level of a virtual router for a VRRP group. VRRP interface tracking monitors a specific interface IP state within the router. Depending on the state of the tracked interface, the feature can alter the VRRP priority level of a virtual router for a VRRP group. NOTE: An exception to the priority level change is that if the VRRP group is the IP address owner, its priority is fixed at 255 and cannot be reduced through the tracking process. Configuring VRRP 1035 With standard VRRP, the backup router takes over only if the router goes down. With VRRP interface tracking, if a tracked interface goes down on the VRRP master, the priority decrement value is subtracted from the router priority. If the master router priority becomes less than the priority on the backup router, the backup router takes over. If the tracked interface becomes up, the value of the priority decrement is added to the current router priority. If the resulting priority is more than the backup router priority, the original VRRP master resumes control. VRRP route tracking monitors the reachability of an IP route. A tracked route is considered up when a routing table entry exists for the route and the route is accessible. When the tracked route is removed from the routing table, the priority of the VRRP router will be reduced by the priority decrement value. When the tracked route is added to the routing table, the priority will be incremented by the same. 1036 Configuring VRRP Default VRRP Values Table 36-1 shows the global default values for VRRP. Table 36-1. VRRP Defaults Parameter Default Value Admin Mode Disabled Virtual Router ID (VRID) None (Range 1-255) Preempt Mode Enabled Preempt Delay 0 Seconds Learn Advertisement Timer Interval Enabled Accept Mode Disabled Priority 100 Advertisement Interval 1 Authentication None Route Tracking No routes tracked Interface Tracking No interfaces tracked Configuring VRRP 1037 Configuring VRRP Features (Web) This section provides information about the OpenManage Switch Administrator pages for configuring and monitoring VRRP features on a PowerConnect 7000 Series switch. For details about the fields on a page, click at the top of the page. VRRP Configuration Use the Configuration page to enable or disable the administrative status of a virtual router. To display the page, click Routing → VRRP → Configuration in the navigation panel. Figure 36-1. VRRP Configuration 1038 Configuring VRRP VRRP Virtual Router Status Use the Router Status page to display virtual router status. To display the page, click Routing → VRRP → Router Status in the navigation panel. Figure 36-2. Virtual Router Status Configuring VRRP 1039 VRRP Virtual Router Statistics Use the Router Statistics page to display statistics for a specified virtual router. To display the page, click Routing → VRRP → Router Statistics in the navigation panel. Figure 36-3. Virtual Router Statistics 1040 Configuring VRRP VRRP Router Configuration Use the Configuration page to configure a virtual router. To display the page, click Routing → VRRP → Router Configuration → Configuration in the navigation panel. Figure 36-4. VRRP Router Configuration Configuring VRRP 1041 VRRP Route Tracking Configuration Use the Route Tracking Configuration page to view routes that are tracked by VRRP and to add new tracked routes. To display the page, click Routing → VRRP → Router Configuration → Route Tracking Configuration in the navigation panel. Figure 36-5. VRRP Route Tracking Configuration Configuring VRRP Route Tracking To configure VRRP route tracking: 1 From the Route Tracking Configuration page, click Add. The Add Route Tracking page displays. 1042 Configuring VRRP Figure 36-6. Add Route Tracking 2 Select the virtual router ID and VLAN routing interface that will track the route. 3 Specify the destination network address (track route prefix) for the route to track. Use dotted decimal format, for example 192.168.10.0. 4 Specify the prefix length for the tracked route. 5 Specify a value for the Priority Decrement to define the amount that the router priority will be decreased when a tracked route becomes unreachable. 6. Click Apply to update the switch. Configuring VRRP 1043 VRRP Interface Tracking Configuration Use the Interface Tracking Configuration page to view interfaces that are tracked by VRRP and to add new tracked interfaces. To display the page, click Routing → VRRP → Router Configuration → Interface Tracking Configuration in the navigation panel. Figure 36-7. VRRP Interface Tracking Configuration Configuring VRRP Interface Tracking To configure VRRP interface tracking: 1 From the Interface Tracking Configuration page, click Add. The Add Interface Tracking page displays. 1044 Configuring VRRP Figure 36-8. VRRP Interface Tracking Configuration 2 Select the virtual router ID and VLAN routing interface that will track the interface. 3 Specify the interface to track. 4 Specify a value for the Priority Decrement to define the amount that the router priority will be decreased when a tracked interface goes down. 5. Click Apply to update the switch. Configuring VRRP 1045 Configuring VRRP Features (CLI) This section provides information about the commands you use to configure VRRP settings on the switch. For more information about the commands, see the PowerConnect 7000 Series CLI Reference Guide at support.dell.com/manuals. Configuring VRRP Settings Beginning in Privileged EXEC mode, use the following commands to configure switch and interface VRRP settings. This set of commands also describes how to configure VRRP interface and route tracking. Command Purpose configure Enter global configuration mode. ip vrrp Enable the administrative mode of VRRP for the router (L3 switch). interface vlan vlan-id Enter Interface Configuration mode for the specified VLAN. vrrp vr-id Allow the interface to create in the VRRP group specified by the vr-id parameter, which is a number from 1–255. vrrp vr-id description (Optional) Create a text description that identifies the VRRP group. vrrp vr-id preempt [delay Enable the preemption mode value for the virtual router seconds] configured on a specified interface. You can optionally configure a preempt delay, which is the number of seconds the VRRP router waits before the VRRP router sends an advertisement to claim master ownership. vrrp vr-id accept-mode Allow the VRRP master to accept ping packets sent to one of the virtual router’s IP addresses. vrrp vr-id priority priority Set the priority value for the virtual router configured on the interface. vrrp vr-id ip ip-address [secondary] Set the virtual router IP address value for an interface. 1046 Configuring VRRP Command Purpose vrrp vr-id timers {learn | Configure the VRRP timer settings. advertise seconds} Use the keyword learn to enable VRRP to learn the advertisement timer interval of the master router. Use the keyword advertise to set the frequency, in seconds, that an interface on the specified virtual router sends a virtual router advertisement. vrrp vr-id authentication Set the authorization details value for the virtual router configured on a specified interface. {none | simple key} • vr-id — The virtual router identifier. (Range: 1-255) • none — Indicates authentication type is none. • simple — Authentication type is a simple text password. • key — The key for simple authentication. (Range: String values) vrrp vr-id mode Enable the virtual router configured on an interface, which starts the virtual router. vrrp vr-id track interface Specify an interface the virtual router (vr-id) on the vlan vlan-id [decrement interface will track. If the interface goes down, the virtual priority] router priority is decreased by the amount specified by the priority value. vrrp vr-id track ip route Specify a route that the virtual router (vr-id) on the interface will track. If the route to the destination network specified by the ip-address/prefix-length variable is removed from the routing table, the virtual router priority is decreased by the amount specified by the priority value. CTRL + Z Exit to Privileged EXEC mode. show vrrp [vr-id] View settings for all VRRP groups or for the specified VRRP group for the switch. show vrrp brief View a summary of interfaces configured to participate in VRRP groups. show vrrp interface {brief | vlan vlan-id [stats]} View information about VRRP settings configured on all interfaces or on the specified interface. If you specify an interface, use the keyword stats to view VRRP statistics for the interface. ip-address/prefix-length [decrement priority] Configuring VRRP 1047 VRRP Configuration Example This section contains the following VRRP examples: • VRRP with Load Sharing • VRRP with Route and Interface Tracking VRRP with Load Sharing In Figure 36-9, two L3 PowerConnect switches are performing the routing for network clients. Router A is the default gateway for some clients, and Router B is the default gateway for other clients. Figure 36-9. VRRP with Load Sharing Network Diagram 1048 Configuring VRRP This example configures two VRRP groups on each router. Router A is the VRRP master for the VRRP group with VRID 10 and the backup for VRID 20. Router B is the VRRP master for VRID 20 and the backup for VRID 10. If Router A fails, Router B will become the master of VRID 10 and will use the virtual IP address 192.168.10.1. Traffic from the clients configured to use Router A as the default gateway will be handled by Router B. To configure Router A: 1 Enable routing for the switch. console#config console(config)#ip routing 2 Create and configure the VLAN routing interface to use as the default gateway for network clients. This example assumes all other routing interfaces, such as the interface to the external network, have been configured. console(config)#interface vlan 10 console(config-if-vlan10)#ip address 192.168.10.1 255.255.255.0 console(config-if-vlan10)#exit 3 Enable VRRP for the switch. console(config)#ip vrrp 4 Assign a virtual router ID to the VLAN routing interface for the first VRRP group. console(config)#interface vlan 10 console(config-if-vlan10)#vrrp 10 5 Specify the IP address that the virtual router function will use. The router is the virtual IP address owner (the routing interface has the same IP address as the virtual IP address for the VRRP group), so the priority value is 255. console(config-if-vlan10)#vrrp 10 ip 192.168.10.1 6 Configure an optional description to help identify the VRRP group. console(config-if-vlan10)#vrrp 10 description master 7 Assign a virtual router ID to the VLAN routing interface for the second VRRP group. console(config-if-vlan10)#vrrp 20 8 Specify the IP address that the virtual router function will use. console(config-if-vlan10)#vrrp 20 ip 192.168.10.2 Configuring VRRP 1049 9 Configure an optional description to help identify the VRRP group. console(config-if-vlan10)#vrrp 20 description backup 10 Enable the VRRP groups on the interface. console(config-if-vlan10)#ip vrrp 10 mode console(config-if-vlan10)#ip vrrp 20 mode console(config-if-vlan10)#exit console(config)#exit The only difference between the Router A and Router B configurations is the IP address assigned to VLAN 10. On Router B, the IP address of VLAN 10 is 192.168.10.2. Because this is also the virtual IP address of VRID 20, Router B is the interface owner and VRRP master of VRRP group 20. To configure Router B: 1 Enable routing for the switch. console#config console(config)#ip routing 2 Create and configure the VLAN routing interface to use as the default gateway for network clients. This example assumes all other routing interfaces, such as the interface to the external network, have been configured. console(config)#interface vlan 10 console(config-if-vlan10)#ip address 192.168.10.2 255.255.255.0 console(config-if-vlan10)#exit 3 Enable VRRP for the switch. console(config)#ip vrrp 4 Assign a virtual router ID to the VLAN routing interface for the first VRRP group. console(config)#interface vlan 10 console(config-if-vlan10)#vrrp 10 5 Specify the IP address that the virtual router function will use. console(config-if-vlan10)#vrrp 10 ip 192.168.10.1 6 Configure an optional description to help identify the VRRP group. console(config-if-vlan10)#vrrp 10 description master 7 Assign a virtual router ID to the VLAN routing interface for the second VRRP group. console(config-if-vlan10)#vrrp 20 1050 Configuring VRRP 8 Specify the IP address that the virtual router function will use. The router is the virtual IP address owner of this address, so the priority value is 255 by default. console(config-if-vlan10)#vrrp 20 ip 192.168.10.2 9 Configure an optional description to help identify the VRRP group. console(config-if-vlan10)#vrrp 20 description backup 10 Enable the VRRP groups on the interface. console(config-if-vlan10)#ip vrrp 10 mode console(config-if-vlan10)#ip vrrp 20 mode console(config-if-vlan10)#exit console(config)#exit Configuring VRRP 1051 VRRP with Route and Interface Tracking In Figure 36-10, the VRRP priorities are configured so that Router A is the VRRP master, and Router B is the VRRP backup. Router A forwards IP traffic from clients to the external network through the VLAN 25 routing interface. The clients are configured to use the virtual IP address 192.168.10.15 as the default gateway. Figure 36-10. VRRP with Tracking Network Diagram Without VRRP interface or route tracking, if something happened to VLAN 25 or the route to the external network, as long as Router A remains up, it will continue to be the VRRP master even though traffic from the clients does not have a path to the external network. However, if the interface and/or route tracking features are configured, Router A can decrease its priority value when the problems occur so that Router B becomes the master. 1052 Configuring VRRP To configure Router A: 1 Enable routing for the switch. console#config console(config)#ip routing 2 Create and configure the VLAN routing interface to use as the default gateway for network clients. This example assumes all other routing interfaces, such as the interface to the external network, have been configured. console(config)#interface vlan 10 console(config-if-vlan10)#ip address 192.168.10.1 255.255.255.0 console(config-if-vlan10)#exit 3 Enable VRRP for the switch. console(config)#ip vrrp 4 Assign a virtual router ID to the VLAN routing interface for the VRRP group. console(config)#interface vlan 10 console(config-if-vlan10)#vrrp 10 5 Specify the IP address that the virtual router function will use. console(config-if-vlan10)#vrrp 10 ip 192.168.10.15 6 Configure the router priority. console(config-if-vlan10)#vrrp 10 priority 200 7 Enable preempt mode so that the router can regain its position as VRRP master if its priority is greater than the priority of the backup router. console(config-if-vlan10)#vrrp 10 preempt 8 Enable the VRRP groups on the interface. console(config-if-vlan10)#ip vrrp 10 mode console(config-if-vlan10)#exit 9 Track the routing interface VLAN 25 on VRID 10 so that if it goes down, the priority of VRID 10 on Router A is decreased by 10, which is the default decrement priority value. console(config-if-vlan10)#vrrp 10 track interface vlan 25 10 Track the route to the 192.168.200.0 network. If it becomes unavailable, the priority of VRID 10 on Router A is decreased by 10, which is the default decrement priority value. Configuring VRRP 1053 console(config-if-vlan10)#vrrp 10 track ip route 192.168.200.0/24 console(config-if-vlan10)#exit Router B is the backup router for VRID 10. The configured priority is 195. If the VLAN 25 routing interface or route to the external network on Router A go down, the priority of Router A will become 190 (or 180, if both the interface and router are down). Because the configured priority of Router B is greater than the actual priority of Router A, Router B will become the master for VRID 10. When VLAN 25 and the route to the external network are back up, the priority of Router A returns to 200, and it resumes its role as VRRP master. To configure Router B: 1 Enable routing for the switch. console#config console(config)#ip routing 2 Create and configure the VLAN routing interface to use as the default gateway for network clients. This example assumes all other routing interfaces, such as the interface to the external network, have been configured. console(config)#interface vlan 10 console(config-if-vlan10)#ip address 192.168.10.2 255.255.255.0 console(config-if-vlan10)#exit 3 Enable VRRP for the switch. console(config)#ip vrrp 4 Assign a virtual router ID to the VLAN routing interface for the VRRP group. console(config)#interface vlan 10 console(config-if-vlan10)#vrrp 10 5 Specify the IP address that the virtual router function will use. console(config-if-vlan10)#vrrp 10 ip 192.168.10.15 6 Configure the router priority. console(config-if-vlan10)#vrrp 10 priority 195 7 Enable preempt mode so that the router can regain its position as VRRP master if its priority is greater than the priority of the backup router. console(config-if-vlan10)#vrrp 10 preempt 1054 Configuring VRRP 8 Enable the VRRP groups on the interface. console(config-if-vlan10)#ip vrrp 10 mode console(config-if-vlan10)#exit console(config)#exit Configuring VRRP 1055 1056 Configuring VRRP Configuring IPv6 Routing 37 This chapter describes how to configure general IPv6 routing information on the switch, including global routing settings and IPv6 static routes. The topics covered in this chapter include: • IPv6 Routing Overview • Default IPv6 Routing Values • Configuring IPv6 Routing Features (Web) • Configuring IPv6 Routing Features (CLI) The PowerConnect 7000 Series switches support additional features to help manage IPv6 networks, including OSPFv3, DHCPv6, and IPv6 multicast. For information about OSPFv3, see "Configuring OSPF and OSPFv3" on page 931. For information about DHCPv6, see "Configuring DHCPv6 Server and Relay Settings" on page 1081. For information about IPv6 multicast, see "Managing IPv4 and IPv6 Multicast" on page 1153. For configuration examples that include IPv6 interface configuration, see "OSPF Configuration Examples" on page 997 IPv6 Routing Overview IPv6 is the next generation of the Internet Protocol. With 128-bit addresses, versus 32-bit addresses for IPv4, IPv6 solves the address depletion issues seen with IPv4 and removes the requirement for Network Address Translation (NAT), which is used in IPv4 networks to reduce the number of globally unique IP addresses required for a given network. On the PowerConnect 7000 Series switch, IPv6 coexists with IPv4. As with IPv4, IPv6 routing can be enabled on loopback and VLAN interfaces. Each L3 routing interface can be used for IPv4, IPv6, or both. IP protocols running over L3 (for example, UDP and TCP) are common to both IPv4 and IPv6. Configuring IPv6 Routing 1057 How Does IPv6 Compare with IPv4? There are many conceptual similarities between IPv4 and IPv6 network operation. Addresses still have a network prefix portion (network) and a device interface specific portion (host). While the length of the network portion is still variable, most users have standardized on using a network prefix length of 64 bits. This leaves 64 bits for the interface specific portion, called an Interface ID in IPv6. Depending upon the underlying link addressing, the Interface ID can be automatically computed from the link (e.g., MAC address). Such an automatically computed Interface ID is called an EUI-64 identifier, which is the interface MAC address with ff:fe inserted in the middle. IPv6 packets on the network are of an entirely different format than traditional IPv4 packets and are also encapsulated in a different EtherType (86DD rather than 0800 which is used with IPv4). The details for encapsulating IPv6 in Ethernet frames are described in RFC2462. Unlike IPv4, IPv6 does not have broadcasts. There are two types of IPv6 addresses — unicast and multicast. Unicast addresses allow direct one-to-one communication between two hosts, whereas multicast addresses allow one-tomany communication. Multicast addresses are used as destinations only. Unicast addresses will have 00 through fe in the most significant octets and multicast addresses will have ff in the most significant octets. How Are IPv6 Interfaces Configured? In PowerConnect 7000 Series switch software, IPv6 coexists with IPv4. As with IPv4, IPv6 routing can be enabled on VLAN interfaces. Each L3 routing interface can be used for IPv4, IPv6, or both simultaneously. Neighbor Discovery (ND) protocol is the IPv6 replacement for Address Resolution Protocol (ARP) in IPv4. The IPv6 Neighbor Discovery protocol is described in detail in RFC4861. Router advertisement is part of the Neighbor Discovery process and is required for IPv6. As part of router advertisement, PowerConnect 7000 Series switch software supports stateless auto configuration of end nodes. The switch supports both EUI-64 interface identifiers and manually configured interface IDs. While optional in IPv4, router advertisement is mandatory in IPv6. Router advertisements specify the network prefix(es) on a link which can be used by receiving hosts, in conjunction with an EUI-64 identifier, to autoconfigure a 1058 Configuring IPv6 Routing host’s address. Routers have their network prefixes configured and may use EUI-64 or manually configured interface IDs. In addition to zero or more global addresses, each IPv6 interface also has an autoconfigured “link-local” address which is: • fe80::/10, with the EUI-64 address in the least significant bits. • Reachable only on the local VLAN — link-local addresses are never routed. • Not globally unique Next hop addresses computed by routing protocols are usually link-local addresses. During the period of transitioning the Internet to IPv6, a global IPv6 Internet backbone may not be available. One transition mechanism is to tunnel IPv6 packets inside IPv4 to reach remote IPv6 islands. When a packet is sent over such a link, it is encapsulated in IPv4 in order to traverse an IPv4 network and has the IPv4 headers removed at the other end of the tunnel. Default IPv6 Routing Values IPv6 is disabled by default on the switch and on all interfaces. Table 37-1 shows the default values for the IP routing features this chapter describes. Table 37-1. IPv6 Routing Defaults Parameter Default Value IPv6 Unicast Routing Mode Disabled IPv6 Hop Limit Unconfigured ICMPv6 Rate Limit Error Interval 1000 milliseconds ICMPv6 Rate Limit Burst Size 100 Interface IPv6 Mode Disabled IPv6 Router Route Preferences Local—0 Static—1 OSPFv3 Intra—110 OSPFv3 Inter—110 OSPFv3 External—110 Configuring IPv6 Routing 1059 Table 37-2 shows the default IPv6 interface values after a VLAN routing interface has been created. Table 37-2. IPv6 Interface Defaults Parameter Default Value IPv6 Mode Disabled DHCPv6 Client Mode Disabled Stateless Address AutoConfig Mode Disabled Routing Mode Enabled Interface Maximum Transmit Unit 1500 Router Duplicate Address Detection Transmits 1 Router Advertisement NS Interval Not configured Router Lifetime Interval 1800 seconds Router Advertisement Reachable Time 0 seconds Router Advertisement Interval 600 seconds Router Advertisement Managed Config Flag Disabled Router Advertisement Other Config Flag Disabled Router Advertisement Suppress Flag Disabled IPv6 Destination Unreachables Enabled 1060 Configuring IPv6 Routing Configuring IPv6 Routing Features (Web) This section provides information about the OpenManage Switch Administrator pages for configuring and monitoring IPv6 unicast routing features on a PowerConnect 7000 Series switch. For details about the fields on a page, click at the top of the page. Global Configuration Use the Global Configuration page to enable IPv6 forwarding on the router, enable the forwarding of IPv6 unicast datagrams, and configure global IPv6 settings. To display the page, click Routing → IPv6 → Global Configuration in the navigation panel. Figure 37-1. IPv6 Global Configuration Configuring IPv6 Routing 1061 Interface Configuration Use the Interface Configuration page to configure IPv6 interface parameters. This page has been updated to include the IPv6 Destination Unreachables field. To display the page, click Routing → IPv6 → Interface Configuration in the navigation panel. Figure 37-2. IPv6 Interface Configuration 1062 Configuring IPv6 Routing Interface Summary Use the Interface Summary page to display settings for all IPv6 interfaces. To display the page, click Routing → IPv6 → Interface Summary in the navigation panel. Figure 37-3. IPv6 Interface Summary Configuring IPv6 Routing 1063 IPv6 Statistics Use the IPv6 Statistics page to display IPv6 traffic statistics for one or all interfaces. To display the page, click Routing → IPv6 → IPv6 Statistics in the navigation panel. Figure 37-4. IPv6 Statistics 1064 Configuring IPv6 Routing IPv6 Neighbor Table Use the IPv6 Neighbor Table page to display IPv6 neighbor details for a specified interface. To display the page, click IPv6 → IPv6 Neighbor Table in the navigation panel. Figure 37-5. IPv6 Neighbor Table Configuring IPv6 Routing 1065 DHCPv6 Client Parameters Use the DHCPv6 Client Parameters page to view information about the network information automatically assigned to an interface by the DHCPv6 server. This page displays information only if the DHCPv6 client has been enabled on an IPv6 routing interface. To display the page, click Routing → IPv6 → DHCPv6 Client Parameters in the navigation panel. Figure 37-6. DHCPv6 Client Parameters 1066 Configuring IPv6 Routing IPv6 Route Entry Configuration Use the IPv6 Route Entry Configuration page to configure information for IPv6 routes. To display the page, click Routing → IPv6 → IPv6 Routes → IPv6 Route Entry Configuration in the navigation panel. Figure 37-7. IPv6 Route Entry Configuration Configuring IPv6 Routing 1067 IPv6 Route Table Use the IPv6 Route Table page to display all active IPv6 routes and their settings. To display the page, click Routing → IPv6 → IPv6 Routes → IPv6 Route Table in the navigation panel. Figure 37-8. IPv6 Route Table 1068 Configuring IPv6 Routing IPv6 Route Preferences Use the IPv6 Route Preferences page to configure the default preference for each protocol. These values are arbitrary values in the range of 1 to 255 and are independent of route metrics. Most routing protocols use a route metric to determine the shortest path known to the protocol, independent of any other protocol. The best route to a destination is chosen by selecting the route with the lowest preference value. When there are multiple routes to a destination, the preference values are used to determine the preferred route. If there is still a tie, the route with the best route metric is chosen. To avoid problems with mismatched metrics, you must configure different preference values for each of the protocols. To display the page, click Routing → IPv6 → IPv6 Routes → IPv6 Route Preferences in the navigation panel. Figure 37-9. IPv6 Route Preferences Configuring IPv6 Routing 1069 Configured IPv6 Routes Use the Configured IPv6 Routes page to display selected IPv6 routes. NOTE: For a static reject route, the next hop interface value is Null0. Packets to the network address specified in static reject routes are intentionally dropped. To display the page, click Routing → IPv6 → IPv6 Routes → Configured IPv6 Routes in the navigation panel. Figure 37-10. Configured IPv6 Routes To remove a configured route, select the check box in the Delete column of the route to remove, and click Apply. 1070 Configuring IPv6 Routing Configuring IPv6 Routing Features (CLI) This section provides information about the commands you use to configure IPv6 routing on the switch. For more information about the commands, see the PowerConnect 7000 Series CLI Reference Guide at support.dell.com/manuals. Configuring Global IP Routing Settings Beginning in Privileged EXEC mode, use the following commands to configure various global IP routing settings for the switch. Command Purpose configure Enter global configuration mode. sdm prefer dual-ipv4and-ipv6 default Select a Switch Database Management (SDM) template to enable support for both IPv4 and IPv6. Changing the SDM template requires a system reload. ipv6 unicast-routing Globally enable IPv6 routing on the switch. ipv6 hop-limit limit Set the TTL value for the router. The valid range is 0 to 255. ipv6 icmp error-interval Limit the rate at which IPv4 ICMP error messages are sent. burst-interval [burstsize] • burst-interval — How often the token bucket is initialized (Range: 0–2147483647 milliseconds). • burst-size — The maximum number of messages that can be sent during a burst interval (Range: 1–200). exit Exit to Privileged EXEC mode. Configuring IPv6 Routing 1071 Configuring IPv6 Interface Settings Beginning in Privileged EXEC mode, use the following commands to configure IPv6 settings for VLAN, tunnel, or loopback interfaces. Command Purpose configure Enter Global Configuration mode. interface {vlan | tunnel | loopback} Enter Interface Configuration mode for the specified VLAN, tunnel, or loopback interface. ipv6 enable Enable IPv6 on the interface. Configuring an IPv6 address will automatically enable IPv6 on the interface. ipv6 address {autoconfig | dhcp | Configure the IPv6 address and network prefix length. Setting an IPv6 address enables IPv6 on the interface. You can also use the ipv6 enable command to enable IPv6 on the interface without setting an address. interface-id prefix/prefix-length [eui64]} Link-local, multicast, IPv4-compatible, and IPv4-mapped addresses are not allowed to be configured. Include the EUI-64 keyword to have the system add the 64bit interface ID to the address. You must use a network prefix length of 64 in this case. For VLAN interfaces, use the dhcp keyword to enable the DHCPv6 client and obtain an IP address form a network DHCPv6 server. ipv6 mtu size (VLAN interfaces only) Set the IPv6 Maximum Transmission Unit (MTU) on a routing interface. The IPv6 MTU is the size of the largest IPv6 packet that can be transmitted on the interface without fragmentation. The range is 1280–1500 bytes. ipv6 traffic-filter ACL Add an access-list filter to this interface. name ipv6 unreachables (VLAN interfaces only) Allow the interface to send ICMPv6 Destination Unreachable messages. The no ipv6 unreachables command suppresses the ICMPv6 unreachable messages for this interface. exit Exit the interface configuration mode. 1072 Configuring IPv6 Routing Configuring IPv6 Neighbor Discovery Use the following commands to configure IPv6 Neighbor Discovery settings. Command Purpose ipv6 nd prefix Configure parameters associated with network prefixes that the router advertises in its Neighbor Discovery advertisements. prefix/prefix-length [{valid-lifetime| infinite} {preferredlifetime| infinite}] [no-autoconfig] [offlink] • ipv6-prefix—IPv6 network prefix. • prefix-length—IPv6 network prefix length. • valid-lifetime—Valid lifetime of the router in seconds. (Range: 0–4294967295 seconds.) • infinite—Indicates lifetime value is infinite. • preferred-lifetime—Preferred-lifetime of the router in seconds. (Range: 0–4294967295 seconds.) • no-autoconfig—Do not use the prefix for auto configuration. • off-link—Do not use the prefix for onlink determination. ipv6 nd ra-interval maximum minimum Set the transmission interval between router Neighbor Discovery advertisements. • maximum — The maximum interval duration (Range: 4–1800 seconds). • minimum — The minimum interval duration (Range: 3 – (0.75 * maximum) seconds). ipv6 nd ra-lifetime seconds Set the value that is placed in the Router Lifetime field of the router Neighbor Discovery advertisements sent from the interface. The seconds value must be zero, or it must be an integer between the value of the router advertisement transmission interval and 9000 seconds. A value of zero means this router is not to be used as the default router. (Range: 0-9000). ipv6 nd suppress-ra Suppress router advertisement transmission on an interface. ipv6 nd dad attempts Set the number of duplicate address detection probes transmitted while doing Neighbor Discovery. value The range for value is 0–600. Configuring IPv6 Routing 1073 Command Purpose ipv6 nd ns-interval milliseconds Set the interval between router advertisements for advertised neighbor solicitations. The range is 1000 to 4294967295 milliseconds. ipv6 nd other-configflag Set the other stateful configuration flag in router advertisements sent from the interface. ipv6 nd managedconfig-flag Set the managed address configuration flag in router advertisements. When the value is true, end nodes use DHCPv6. When the value is false, end nodes automatically configure addresses. ipv6 nd reachabletime milliseconds Set the router advertisement time to consider a neighbor reachable after neighbor discovery confirmation. 1074 Configuring IPv6 Routing Configuring IPv6 Route Table Entries and Route Preferences Beginning in Privileged EXEC mode, use the following commands to configure IPv6 Static Routes. Command Purpose configure Enter global configuration mode. ipv6 route ipv6prefix/prefix-length {nexthop-address | interfacetype interface-number next-hop-address } [preference] Configure a static route.Use the keyword null instead of the next hop router IP address to configure a static reject route. • prefix/prefix-length—The IPv6 network prefix and prefix length that is the destination of the static route. Use the ::/0 form (unspecified address and zero length prefix) to specify a default route. • interface-type interface-number—Must be specified when using a link-local address as the next hop. The interface-type can be vlan or tunnel. • next-hop-address —The IPv6 address of the next hop that can be used to reach the specified network. A linklocal next hop address must have a prefix length of 128. The next hop address cannot be an unspecified address (all zeros), a multicast address, or a loopback address. If a link local next hop address is specified, the interface (VLAN or tunnel), must also be specified. • preference—Also known as Administrative Distance, a metric the router uses to compare this route with routes from other route sources that have the same network prefix. (Range: 1-255). Lower values have precedence over higher values. The default preference for static routes is 1. Routes with a preference of 255 are considered as “disabled” and will not be used for forwarding. Routes with a preference metric of 254 are used by the local router but will never be advertised to other neighboring routers. ipv6 route ipv6prefix/prefix-length null [preference] Configure a static reject route. IPv6 packets matching the reject route will be silently discarded. Configuring IPv6 Routing 1075 Command Purpose ipv6 route distance Set the default distance (preference) for static IPv6 routes. Lower route preference values are preferred when determining the best route. The default distance (preference) for static routes is 1. exit Exit to Global Config mode. integer 1076 Configuring IPv6 Routing IPv6 Show Commands Use the following commands in Privileged EXEC mode to view IPv6 configuration status and related data. Command Purpose show sdm prefer Show the currently active SDM template. show sdm prefer dualipv4-and-ipv6 default Show parameters for the SDM template. show ipv6 dhcp interface vlan vlan-id View information about the DHCPv6 lease acquired by the specified interface. show ipv6 interface {vlan View the IP interface configuration information for the | tunnel | loopback} specified IPv6 routing interface. interface-id show ipv6 brief View the global IPv6 settings for the switch. show ipv6 route [ipv6address | ipv6prefix/prefix-length | protocol | interface-type interface-number] [best] View the routing table. • ipv6-address—Specifies an IPv6 address for which the best-matching route would be displayed. • protocol—Specifies the protocol that installed the routes. Is one of the following keywords: connected, ospf, static. • ipv6-prefix/ prefix-length—Specifies an IPv6 network for which the matching route would be displayed. • interface-type interface-number—Valid IPv6 interface. Specifies that the routes with next-hops on the selected interface be displayed. • best—Specifies that only the best routes are displayed. If the connected keyword is selected for protocol, the best option is not available because there are no best or non-best connected routes. show ipv6 route summary View summary information about the IPv6 routing table. show ipv6 route preferences View detailed information about the IPv6 route preferences. Configuring IPv6 Routing 1077 IPv6 Static Reject and Discard Routes A static configured route with a next-hop of “null” causes any packet matching the route to disappear or vanish from the network. This type of route is called a “Discard” route if the router returns an ICMP “networkunreachable” message, or is called a “Reject” route if no ICMP message is returned. The PowerConnect 7000 Series switches support “Reject” routes, where any packets matching the route network prefix silently disappear. A common use of a Reject route is to quickly discard packets that cannot be delivered because a valid route to the destination is not known. Without the Reject route, these undeliverable packets will continue to circulate through the network, following the default routes, until their TTL expires. Forwarding packets that cannot be delivered wastes bandwidth, particularly on expensive WAN connections. The Reject route will also suppress a type of “Denial of Service” (DoS) attack where an internal host sends large numbers of packets to unknown destinations, causing congestion of the WAN links. • ipv6 route ::/0 null 254 Use this in all routers except the ones with direct Internet connectivity. Routers with direct Internet connectivity should advertise a default route. The effect of this route is that when a router does not have connectivity to the Internet, the router will quickly discard packets that it cannot deliver. If the router learns a default route from another router, the learned route will have a lower distance metric and therefore a higher preference. Routes that are more specific (have more bits in the prefix) will have precedence over less specific routes. This will cause packets destined for non-existent networks to be quickly discarded. Also, because of the high distance metric (254), this route will never be advertised to any neighbor routers. • ipv6 route fc00::/7 null 254 This route covers the entire ULA (IPv6 private) address space. If you have networks configured in this address space, you will have more specific routes for those networks. The more specific routes (more bits of prefix) will have precedence over this route. Any destinations in this range not known via another, more specific route do not exist. The effect is that packets destined for private networks that do not exist in your network will be quickly discarded instead of being forwarded to the default route. 1078 Configuring IPv6 Routing • ipv6 route 2001::/16 null 254 ipv6 route 2002::/16 null 254 These address ranges are reserved and not reachable in the Internet. If for some reason you have local networks in this range, a more specific route will have precedence. Another use for the Reject route is to prevent internal hosts from communication with specific addresses or ranges of addresses. The effect is the same as an outgoing access-list with a “deny” statement. A route is generally more efficient than an access-list that performs the same function. If you need more fine-grained filtering, such as protocols or port numbers, use the access-list instead. Configuring IPv6 Routing 1079 1080 Configuring IPv6 Routing 38 Configuring DHCPv6 Server and Relay Settings This chapter describes how to configure the switch to dynamically assign network information to IPv6 hosts by using the Dynamic Host Configuration Protocol for IPv6 (DHCPv6). The topics covered in this chapter include: • DHCPv6 Overview • Default DHCPv6 Server and Relay Values • Configuring the DHCPv6 Server and Relay (Web) • Configuring the DHCPv6 Server and Relay (CLI) • DHCPv6 Configuration Examples DHCPv6 Overview DHCP is a protocol that is generally used between clients and servers for the purpose of assigning IP addresses, gateways, and other networking definitions such as Domain Name System (DNS) and Network Time Protocol (NTP) parameters. However, IPv6 natively provides IP address auto configuration through IPv6 Neighbor Discovery Protocol (NDP) and through the use of Router Advertisement messages. Thus, the role of DHCPv6 within the network is different than that of DHCPv4 because DHCPv6 is not the primary source for IP address assignment. DHCPv6 server and client interactions are described by RFC 3315 [6]. There are many similarities between DHCPv6 and DHCPv4 interactions and options, but there are enough differences in the messages and option definitions that there is no DHCPv4 to DHCPv6 migration or interoperability. Configuring DHCPv6 Server and Relay Settings 1081 What Is a DHCPv6 Pool? DHCPv6 pools are used to specify information for DHCPv6 server to distribute to DHCPv6 clients. These pools are shared between multiple interfaces over which DHCPv6 server capabilities are configured. What Is a Stateless Server? DHCPv6 incorporates the notion of the stateless server, where DHCPv6 is not used for IP address assignment to a client; rather, it provides other networking information such as DNS or NTP information. The stateless server behavior is described by RFC 3736 [7], which simply contains descriptions of the portions of RFC 3315 that are necessary for stateless server behavior. In order for a router to drive a DHCPv6 client to utilize stateless DHCPv6, the other stateful configuration option must be configured for neighbor discovery on the corresponding IPv6 router interface. This, in turn, causes DHCPv6 clients to send the DHCPv6 Information Request message in response. A DHCPv6 server then responds by providing only networking definitions such as DNS domain name and server definitions, NTP server definitions, or SIP definitions. What Is the DHCPv6 Relay Agent Information Option? The DHCPv6 Relay Agent Information Option allows for various sub-options to be attached to messages that are being relayed by the local router to a DHCPv6 server. The DHCPv6+ server may in turn use this information in determining an address to assign to a DHCPv6 client.RFC 3315 also describes DHCPv6 Relay Agent interactions, which are very much like DHCPv4 Relay Agents. Additionally, there is a DHCPv6 Relay Agent Option described in RFC 4649, which employs very similar capabilities as those described by the DHCPv4 Relay Agent Option in RFC 2132. What Is a Prefix Delegation? With the larger address space inherent to IPv6, addresses within a network can be allocated more effectively in a hierarchical fashion. DHCPv6 introduces the notion of prefix delegation as described in RFC 3633 as a way for routers to centralize and delegate IP address assignment. Figure 38-1 depicts a typical network scenario where prefix delegation is used. 1082 Configuring DHCPv6 Server and Relay Settings Figure 38-1. DHCPv6 Prefix Delegation Scenario In Figure 38-1, the PowerConnect acts as the Prefix Delegation (PD) server and defines one or more general prefixes to allocate and assign addresses to hosts that may be utilizing IPv6 auto-address configuration or acting as DHCPv6 clients. DHCPv6 clients may request multiple IPv6 prefixes. Also, DHCPv6 clients may request specific IPv6 prefixes. If the configured DHCPv6 pool contains the specific prefix that a DHCPv6 client requests, then that prefix will be delegated to the client. Otherwise, the first available IPv6 prefix within the configured pool will be delegated to the client. Default DHCPv6 Server and Relay Values By default, the DHCPv6 server is disabled, and no address pools are configured. VLAN routing interfaces are not configured to perform DHCPv6 server or DHCPv6 relay functions. Configuring DHCPv6 Server and Relay Settings 1083 Configuring the DHCPv6 Server and Relay (Web) This section provides information about the OpenManage Switch Administrator pages for configuring and monitoring the DHCPv6 server on a PowerConnect 7000 Series switch. For details about the fields on a page, click at the top of the page. DHCPv6 Global Configuration Use the Global Configuration page to configure DHCPv6 global parameters. To display the page, click Routing → IPv6 → DHCPv6 → Global Configuration in the navigation panel. Figure 38-2. DHCPv6 Global Configuration 1084 Configuring DHCPv6 Server and Relay Settings DHCPv6 Pool Configuration Use the Pool Configuration page to set up a pool of DHCPv6 parameters for DHCPv6 clients. The pool is identified with a pool name and contains IPv6 addresses and domain names of DNS servers. To display the page, click Routing → IPv6 → DHCPv6 → Pool Configuration in the navigation panel. Figure 38-3 shows the page when no pools have been created. After a pool has been created, additional fields display. Figure 38-3. Pool Configuration Configuring a DHCPv6 Pool To configure the pool: 1 Open the Pool Configuration page. 2 Select Create from the Pool Name menu and type a name in the Pool Name text box. 3 Click Apply. Configuring DHCPv6 Server and Relay Settings 1085 Figure 38-4. Pool Configuration 4 From the DNS Server Address menu, select an existing DNS Server Address to associate with this pool, or select Add and specify a new server to add. 5 From the Domain Name menu, select an existing domain name to associate with this pool, or select Add and specify a new domain name. 6 Click Apply. 1086 Configuring DHCPv6 Server and Relay Settings Prefix Delegation Configuration Use the Prefix Delegation Configuration page to configure a delegated prefix for a pool. At least one pool must be created using DHCPv6 Pool Configuration before a delegated prefix can be configured. To display the page, click Routing → IPv6 → DHCPv6 → Prefix Delegation Configuration in the navigation panel. Figure 38-5. Prefix Delegation Configuration Configuring DHCPv6 Server and Relay Settings 1087 DHCPv6 Pool Summary Use the Pool Summary page to display settings for all DHCPv6 Pools. At least one pool must be created using DHCPv6 Pool Configuration before the Pool Summary displays. To display the page, click Routing → IPv6 → DHCPv6 → Pool Summary in the navigation panel. Figure 38-6. Pool Summary 1088 Configuring DHCPv6 Server and Relay Settings DHCPv6 Interface Configuration Use the DHCPv6 Interface Configuration page to configure a DHCPv6 interface. To display the page, click Routing → IPv6 → DHCPv6 → Interface Configuration in the navigation panel. The fields that display on the page depend on the selected interface mode. Figure 38-7. DHCPv6 Interface Configuration Configuring DHCPv6 Server and Relay Settings 1089 Figure 38-8 shows the screen when the selected interface mode is Server. Figure 38-8. DHCPv6 Interface Configuration - Server Mode Figure 38-9 shows the screen when the selected interface mode is Relay. Figure 38-9. DHCPv6 Interface Configuration - Relay Mode 1090 Configuring DHCPv6 Server and Relay Settings DHCPv6 Server Bindings Summary Use the Server Bindings Summary page to display all DHCPv6 server bindings. To display the page, click Routing → IPv6 → DHCPv6 → Bindings Summary in the navigation panel. Figure 38-10. Server Bindings Summary Configuring DHCPv6 Server and Relay Settings 1091 DHCPv6 Statistics Use the DHCPv6 Statistics page to display DHCPv6 statistics for one or all interfaces. To display the page, click Routing → IPv6 → DHCPv6 → Statistics in the navigation panel. Figure 38-11. 1092 DHCPv6 Statistics Configuring DHCPv6 Server and Relay Settings Configuring the DHCPv6 Server and Relay (CLI) This section provides information about the commands you use to configure and monitor the DHCP server and address pools. For more information about the commands, see the PowerConnect 7000 Series CLI Reference Guide at support.dell.com/manuals. Configuring Global DHCP Server and Relay Agent Settings Beginning in Privileged EXEC mode, use the following commands to configure settings for the DHCPv6 server. Command Purpose configure Enter Global Configuration mode. service dhcpv6 Enable the DHCPv6 server. ipv6 dhcp relay-agentinfo-opt option Configure a number to represent the DHCPv6 Relay Agent Information Option. The option parameter is an integer from 54–65535. ipv6 dhcp relay-agentinfo-remote-id-subopt suboption Configure a number to represent the DHCPv6 remote-ID sub-option The suboption parameter is an integer from 1–65535. exit Exit to Privileged EXEC mode. show ipv6 dhcp Verify the global DHCPv6 server configuration. Configuring a DHCPv6 Pool for Stateless Server Support Beginning in Privileged EXEC mode, use the following commands to create a pool and configure pool parameters for DHCPv6 clients that obtain IPv6 network information dynamically. Command Purpose configure Enter Global Configuration mode. ipv6 dhcp pool name Create a DHCPv6 pool and enter DHCPv6 pool configuration mode. dns-server ipv6-address Set up to 8 IPv6 DNS server addresses to provide to a DHCPv6 client by the DHCPv6 server. Configuring DHCPv6 Server and Relay Settings 1093 Command Purpose domain-name domain Set up to 5 DNS domain names to provide to a DHCPv6 client by the DHCPv6 server. CTRL + Z Exit to Privileged EXEC mode. show ipv6 dhcp pool [name] View the settings for all DHCPv6 pools or for the specified pool. Configuring a DHCPv6 Pool for Specific Hosts Beginning in Privileged EXEC mode, use the following commands to create a pool and/or configure pool parameters for specific DHCPv6 clients. Command Purpose configure Enter Global Configuration mode. ipv6 dhcp pool name Create a DHCPv6 pool and enter DHCPv6 pool configuration mode. prefix-delegation ipv6prefix/prefix-length client-DUID [name hostname] [validlifetime {valid-lifetime | Define an IPv6 prefixes within a pool for distributing to specific DHCPv6 Prefix delegation clients. infinite}] [preferredlifetime {preferredlifetime | infinite}] • prefix/prefix-length—Delegated IPv6 prefix. • client-DUID—DHCP Unique Identifier for the client (e.g. 00:01:00:09:f8:79:4e:00:04:76:73:43:76'). • hostname—Client hostname used for logging and tracing. (Range: 0-31 characters.) The command allows spaces in the host name. • valid-lifetime—Valid lifetime for delegated prefix. (Range: 0-4294967295 seconds) or use the keyword infinite. • preferred-lifetime—Preferred lifetime for delegated prefix. (Range: 0-4294967295 seconds) or use the keyword infinite. CTRL + Z Exit to Privileged EXEC mode. show ipv6 dhcp pool View information about the DHCPv6 pools configured on the switch. 1094 Configuring DHCPv6 Server and Relay Settings Configuring DHCPv6 Interface Information Beginning in Privileged EXEC mode, use the following commands to configure an interface as a DHCPv6 server or a DHCPv6 relay agent. The server and relay functionality are mutually exclusive. In other words, a VLAN routing interface can be configured as a DHCPv6 server or a DHCPv6 relay agent, but not both. Command Purpose configure Enter Global Configuration mode. Enter interface configuration mode for a tunnel or VLAN interface {tunnel tunnel-id | vlan vlan-id} routing interface to configure as a DHCPv6 relay agent. ipv6 dhcp relay Configure the interface for DHCPv6 relay functionality. {destination relay• destination — Keyword that sets the relay server IPv6 address [interface vlan address. vlan-id] | interface vlan • relay-address — An IPv6 address of a DHCPv6 relay vlan-id} [remote-id server. {duid-ifid | userdefined-string}] • interface — Sets the relay server interface. • vlan-id — A valid VLAN ID. • [remote-id {duid-ifid | user-defined-string}] — The Relay Agent Information Option “remote ID” sub-option to be added to relayed messages. This can either be the special keyword duid-ifid, which causes the “remote ID” to be derived from the DHCPv6 server DUID and the relay interface number, or it can be specified as a userdefined string. exit Exit to Global Configuration Mode interface {tunnel Enter interface configuration mode for a tunnel or VLAN tunnel-id | vlan vlan-id} routing interface to configure with DHCPv6 server functionality. Configuring DHCPv6 Server and Relay Settings 1095 Command Purpose ipv6 dhcp server poolname [rapid-commit] [preference pref-value] Configure DHCPv6 server functionality on the interface. • pool-name — The name of the DHCPv6 pool containing stateless and/or prefix delegation parameters • rapid-commit — Is an option that allows for an abbreviated exchange between the client and server. • pref-value — Preference value—used by clients to determine preference between multiple DHCPv6 servers. (Range: 0-4294967295) CTRL + Z Exit to Privileged Exec Mode. show ipv6 dhcp interface View DHCPv6 information for all interfaces or for the [tunnel tunnel-id | vlan specified interface. vlan-id] Monitoring DHCPv6 Information Beginning in Privileged EXEC mode, use the following commands to view bindings, and statistics, and to clear the information. Command Purpose show ipv6 dhcp binding View the current binding information in the DHCP server database. Specify the IP address to view a specific binding. [address] show ipv6 dhcp statistics View DHCPv6 server and relay agent statistics. clear ipv6 dhcp statistics Reset all DHCPv6 server and relay agent statistics to zero. 1096 Configuring DHCPv6 Server and Relay Settings DHCPv6 Configuration Examples This section contains the following examples: • Configuring a DHCPv6 Stateless Server • Configuring the DHCPv6 Server for Prefix Delegation • Configuring an Interface as a DHCPv6 Relay Agent Configuring a DHCPv6 Stateless Server This example configures a DHCPv6 pool that will provide information for the DHCPv6 server to distribute to DHCPv6 clients that are members of VLAN 100. To define stateless information for the DHCPv6 server to distribute, multiple DNS domain names and DNS server addresses are defined within the pool. VLAN routing interface 100 is configured as a DHCPv6 server. Setting NDP on the interface to send the other-config-flag option allows the interface to prompt DHCPv6 clients to request only stateless server information. To configure the switch: 1 Enable the DHCPv6 feature. console#configure console(config)#service dhcpv6 2 Create the DHCPv6 pool and configure stateless information. console(config)#ipv6 dhcp pool my-pool console(config-dhcp6s-pool)#domain-name pengo.dell.com console(config-dhcp6s-pool)#domain-name dell.com console(config-dhcp6s-pool)#dns-server 2001:DB8:A328:22C::1 console(config-dhcp6s-pool)#dns-server 2001:DB8:A328:22C::2 3 Configure VLAN 100 as a routing interface and assign an IPv6 address. console(config)#interface vlan 100 console(config-if-vlan100)#ipv6 address 2001:DB8:A328:34B::/32 Configuring DHCPv6 Server and Relay Settings 1097 4 Configure the DHCPv6 server functionality on VLAN 100. Clients can use the preference value to determine which DHCPv6 server to use when multiple servers exist. console(config-if-vlan100)#ipv6 dhcp server mypool preference 10 console(config-if-vlan100)#ipv6 nd other-configflag console(config-if-vlan100)#exit Configuring the DHCPv6 Server for Prefix Delegation In this example, VLAN routing interface 200 is configured to delegate specific prefixes to certain DHCPv6 clients. The prefix-to-DUID mapping is defined within the DHCPv6 pool. To configure the switch: 1 Create the DHCPv6 pool and specify the domain name and DNS server information. console(config)#ipv6 dhcp pool my-pool2 console(config-dhcp6s-pool)#domain-name dell.com console(config-dhcp6s-pool)#dns-server 2001:DB8:A328:22C::1 2 Specify the prefix delegations for specific clients. The first two commands provide multiple prefixes to the same client. console(config-dhcp6s-pool)#prefix-delegation 2001:DB8:1000::/32 00:01:00:09:f8:79:4e:00:04:76:73:43:76 validlifetime 600 preferred-lifetime 400 console(config-dhcp6s-pool)#prefix-delegation 2001:DB8:1001::/32 00:01:00:09:f8:79:4e:00:04:76:73:43:76 validlifetime 600 preferred-lifetime 400 1098 Configuring DHCPv6 Server and Relay Settings console(config-dhcp6s-pool)#prefix-delegation 2001:DB8:1002::/32 00:01:00:09:f8:79:4e:00:04:76:73:43:76 validlifetime 600 preferred-lifetime 400 console(config-dhcp6s-pool)#exit 3 Configure the DHCPv6 server functionality on VLAN 200 and specify the pool to use for DHCPv6 clients. console(config)#interface vlan 200 console(config-if-vlan200)#ipv6 dhcp server mypool2 preference 20 Configuring an Interface as a DHCPv6 Relay Agent This example configures a VLAN routing interface as a DHCPv6 Relay. The command defines the destination address of the relay server and the interface used for reachability to the relay server. To configure the switch: 1 Create VLAN 300 and define its IPv6 address. console(config)#interface vlan 300 console(config-if-vlan300)#ipv6 address 2001:DB8:03a::/64 2 Configure the interface as a DHCPv6 relay agent and specify the IPv6 address of the relay server. The command also specifies that the route to the server is through the VLAN 100 routing interface. console(config-if-vlan300)#ipv6 dhcp relay destination FE80::250:A2FF:FEBF:A056 interface vlan 100 console(config-if-vlan300)#exit console(config)#exit 3 View the DHCPv6 configuration for VLAN 300. console#show ipv6 dhcp interface vlan 300 IPv6 Interface.......................... ...Vl300 Mode....................................... Relay Relay Address........... FE80::250:A2FF:FEBF:A056 Configuring DHCPv6 Server and Relay Settings 1099 Relay Interface Number.................. ...Vl100 Relay Remote ID............................. Option Flags................................ 1100 Configuring DHCPv6 Server and Relay Settings 39 Configuring Differentiated Services This chapter describes how to configure the Differentiated Services (DiffServ) feature. DiffServ enables traffic to be classified into streams and given certain QoS treatment in accordance with defined per-hop behaviors. The topics covered in this chapter include: • DiffServ Overview • Default DiffServ Values • Configuring DiffServ (Web) • Configuring DiffServ (CLI) • DiffServ Configuration Examples DiffServ Overview Standard IP-based networks are designed to provide “best effort” data delivery service. Best effort service implies that the network delivers the data in a timely fashion, although there is no guarantee that it will. During times of congestion, packets may be delayed, sent sporadically, or dropped. For typical Internet applications, such as email and file transfer, a slight degradation in service is acceptable and in many cases unnoticeable. Conversely, any degradation of service has undesirable effects on applications with strict timing requirements, such as voice or multimedia. Configuring Differentiated Services 1101 How Does DiffServ Functionality Vary Based on the Role of the Switch? How you configure DiffServ support in PowerConnect 7000 Series switch software varies depending on the role of the switch in your network: • Edge device: An edge device handles ingress traffic, flowing towards the core of the network, and egress traffic, flowing away from the core. An edge device segregates inbound traffic into a small set of traffic classes, and is responsible for determining a packet’s classification. Classification is primarily based on the contents of the Layer 3 and Layer 4 headers, and is recorded in the Differentiated Services Code Point (DSCP) added to a packet’s IP header. • Interior node: A switch in the core of the network is responsible for forwarding packets, rather than for classifying them. It decodes the DSCP in an incoming packet, and provides buffering and forwarding services using the appropriate queue management algorithms. Before configuring DiffServ on PowerConnect 7000 Series switches, you must determine the QoS requirements for the network as a whole. The requirements are expressed in terms of rules, which are used to classify inbound or outbound traffic on a particular interface. What Are the Elements of DiffServ Configuration? During configuration, you define DiffServ rules in terms of classes, policies, and services: • Class: A class consists of a set of rules that identify which packets belong to the class. Inbound traffic is separated into traffic classes based on Layer 2, Layer 3, and Layer 4 header data. The class type All is supported; this specifies that every match criterion defined for the class must be true for a match to occur. • Policy: A policy defines the QoS attributes for one or more traffic classes. An attribute identifies the action taken when a packet matches a class rule. An example of an attribute is to mark a packet. The switch supports the ability to assign traffic classes to output CoS queues, and to mirror incoming packets in a traffic stream to a specific egress interface (physical port or LAG). 1102 Configuring Differentiated Services PowerConnect 7000 Series switch software supports the Traffic Conditioning Policy type which is associated with an inbound traffic class and specifies the actions to be performed on packets meeting the class rules: • – Marking the packet with a given DSCP, IP precedence, or CoS value. Traffic to be processed by the DiffServ feature requires an IP header if the system uses IP Precedence or IP DSCP marking. – Policing packets by dropping or re-marking those that exceed the class’s assigned data rate. – Counting the traffic within the class. Service: Assigns a policy to an interface for inbound traffic. NOTE: You can use an 802.1X authenticator or RADIUS server to dynamically assign DiffServ filters to ports when a host connects to a port and authenticates by using 802.1X. For more information, see "How Does the Authentication Server Assign DiffServ Filters?" on page 489 Default DiffServ Values Table 39-1 shows the global default values for DiffServ. Table 39-1. DiffServ Global Defaults Parameter Default Value DiffServ Enabled Classes None configured Policies None configured Services None configured Configuring Differentiated Services 1103 Configuring DiffServ (Web) This section provides information about the OpenManage Switch Administrator pages for configuring and monitoring DiffServ features on a PowerConnect 7000 Series switch. For details about the fields on a page, click at the top of the page. DiffServ Configuration Use the DiffServ Configuration page to display the DiffServ administrative mode setting as well as the current and maximum number of rows in each of the main DiffServ private MIB tables. To display the page, click Quality of Service → Differentiated Services → DiffServ Configuration in the navigation panel. Figure 39-1. DiffServ Configuration 1104 Configuring Differentiated Services Class Configuration Use the DiffServ Class Configuration page to add a new DiffServ class name, or to rename or delete an existing class. To display the page, click Quality of Service → Differentiated Services → Class Configuration in the navigation panel. Figure 39-2. DiffServ Class Configuration Adding a DiffServ Class To add a DiffServ class: 1 From the DiffServ Class Configuration page, click Add to display the Add Class page. Figure 39-3. Add DiffServ Class 2 Enter a name for the class and select the protocol to use for class match criteria. Configuring Differentiated Services 1105 3 Click Apply to add the new class. 4 To view a summary of the classes configured on the switch, click Show All. Figure 39-4. View DiffServ Class Summary Class Criteria Use the DiffServ Class Criteria page to define the criteria to associate with a DiffServ class. As packets are received, these DiffServ classes are used to identify packets. To display the page, click Quality of Service → Differentiated Services → Class Criteria in the navigation panel. 1106 Configuring Differentiated Services Figure 39-5. DiffServ Class Criteria Configuring Differentiated Services 1107 Policy Configuration Use the DiffServ Policy Configuration page to associate a collection of classes with one or more policy statements. To display the page, click Quality of Service → Differentiated Services → Policy Configuration in the navigation panel. Figure 39-6. DiffServ Policy Configuration Adding a New Policy Name To add a policy: 1 From the DiffServ Policy Configuration page, click Add to display the Add Policy page. 1108 Configuring Differentiated Services Figure 39-7. Add DiffServ Policy 2 Enter the new Policy Name. 3 Click Apply to save the new policy. 4 To view a summary of the policies configured on the switch, click Show All. Figure 39-8. View DiffServ Policies Configuring Differentiated Services 1109 Policy Class Definition Use the DiffServ Policy Class Definition page to associate a class to a policy, and to define attributes for that policy-class instance. To display the page, click Quality of Service → Differentiated Services → Policy Class Definition in the navigation panel. Figure 39-9. DiffServ Policy Class Definition To view a summary of the policy attributes, click Show All. 1110 Configuring Differentiated Services Figure 39-10. Policy Attribute Summary Packet Marking Traffic Condition Follow these steps to have packets that match the class criteria for this policy marked with a marked with either an IP DSCP, IP precedence, or CoS value: 1 Select Marking from the Traffic Conditioning drop-down menu on the DiffServ Policy Class Definition page. The Packet Marking page displays. Figure 39-11. Policy Class Definition - Packet Marking 2 Select IP DSCP, IP Precedence, or Class of Service to mark for this policyclass. 3 Select or enter a value for this field. 4 Click Apply to define the policy-class. Configuring Differentiated Services 1111 Policing Traffic Condition Follow these steps to perform policing on the packets that match this policy class: 1 Select Policing from the Traffic Conditioning drop-down menu on the DiffServ Policy Class Definition page to display the DiffServ Policy Policing page. Figure 39-12. Policy Class Definition - Policing The DiffServ Policy - Policing page displays the Policy Name, Class Name, and Policing Style. Select a value for the following fields: • Color Mode — The type of color policing used: Color Blind or Color Aware. • Conform Action Selector — The action taken on packets that are considered conforming (below the police rate). Options are Send, Drop, Mark CoS, Mark IP DSCP, Mark IP Precedence. • Violate Action — The action taken on packets that are considered non-conforming (above the police rate). Options are Send, Drop, Mark CoS, Mark IP DSCP, Mark IP Precedence. 2 Click Apply. The policy-class is defined, and the device is updated. 1112 Configuring Differentiated Services Service Configuration Use the DiffServ Service Configuration page to activate a policy on a port. To display the page, click Quality of Service → Differentiated Services → Service Configuration in the navigation panel. Figure 39-13. DiffServ Service Configuration To view a summary of the services configured on the switch, click Show All. Figure 39-14. DiffServ Service Summary Configuring Differentiated Services 1113 Service Detailed Statistics Use the DiffServ Service Detailed Statistics page to display packet details for a particular port and class. To display the page, click Quality of Service → Differentiated Services → Service Detailed Statistics in the navigation panel. Figure 39-15. 1114 DiffServ Service Detailed Statistics Configuring Differentiated Services Flow-Based Mirroring Use the Flow-Based Mirroring page to create a mirroring session in which the traffic that matches the specified policy and member class is mirrored to a destination port. To display the Flow-Based Mirroring page, click Switching → Ports → Traffic Mirroring → Flow-Based Mirroring in the navigation panel. Figure 39-16. Flow-Based Mirroring Configuring Differentiated Services 1115 Configuring DiffServ (CLI) This section provides information about the commands you use to configure DiffServ settings on the switch. For more information about the commands, see the PowerConnect 7000 Series CLI Reference Guide at support.dell.com/manuals. DiffServ Configuration (Global) Beginning in Privileged Exec mode, use the following commands in to configure the global DiffServ mode and view related settings. CLI Command Description configure Enter global configuration mode. diffserv Set the DiffServ operational mode to active. exit Exit to Privileged EXEC mode. show diffserv Display the DiffServ general information, which includes the current administrative mode setting as well as the current and maximum number of DiffServ components. DiffServ Class Configuration for IPv4 Beginning in Privileged Exec mode, use the following commands to configure DiffServ classes for IPv4 and view related information. CLI Command Description configure Enter global configuration mode. class-map match-all class-map- Define a new DiffServ class and enter Class-Map name Configuration mode for the specified class. NOTE: To enter Class-Map Configuration mode for a class that has already been created, use the classmap class-map-name command. match any Configure a match condition for all the packets. match class-map Add to the specified class definition the set of match conditions defined for another class. 1116 Configuring Differentiated Services CLI Command Description match cos Add to the specified class definition a match condition for the Class of Service value. match destination-address mac Add to the specified class definition a match condition based on the destination MAC address of a packet. match dstip Add to the specified class definition a match condition based on the destination IP address of a packet. match dstl4port Add to the specified class definition a match condition based on the destination layer 4 port of a packet using a single keyword, or a numeric notation. match ethertype Add to the specified class definition a match condition based on the value of the ethertype. match ip dscp Add to the specified class definition a match condition based on the value of the IP DiffServ Code Point (DSCP) field in a packet. match ip precedence Add to the specified class definition a match condition based on the value of the IP. match ip tos Add to the specified class definition a match condition based on the value of the IP TOS field in a packet. match protocol Add to the specified class definition a match condition based on the value of the IP Protocol field in a packet using a single keyword notation or a numeric value notation. match secondary-cos Configure a match condition based on a secondary COS value. match secondary-vlan Configure a match condition based on a secondary VLAN value. match source-address mac Add to the specified class definition a match condition based on the source MAC address of the packet. Configuring Differentiated Services 1117 CLI Command Description match srcip Add to the specified class definition a match condition based on the source IP address of a packet. match srcl4port Add to the specified class definition a match condition based on the source layer 4 port of a packet using a single keyword, a numeric notation, or a numeric range notation. match vlan Add to the specified class definition a match condition based on the value of the layer 2 VLAN Identifier field. DiffServ Class Configuration for IPv6 Beginning in Privileged Exec mode, use the following commands to configure DiffServ classes for IPv6 and view related information. CLI Command Description configure Enter global configuration mode. class-map match-all class-map- Define a new DiffServ class. name ipv6 match any Configure a match condition for all the packets. match class-map Add to the specified class definition the set of match conditions defined for another class. match dstip6 Add to the specified class definition a match condition based on the destination IPv6 address of a packet. match dstl4port Add to the specified class definition a match condition based on the destination layer 4 port of a packet using a single keyword, or a numeric notation. match ip6flowlbl Add to the specified class definition a match condition based on the IPv6 flow label of a packet. match ip dscp Add to the specified class definition a match condition based on the value of the IP DiffServ Code Point (DSCP) field in a packet. 1118 Configuring Differentiated Services CLI Command Description match protocol Add to the specified class definition a match condition based on the value of the IP Protocol field in a packet using a single keyword notation or a numeric value notation. match source-address mac Add to the specified class definition a match condition based on the source MAC address of the packet. match srcip6 Add to the specified class definition a match condition based on the source IPv6 address of a packet. match srcl4port Add to the specified class definition a match condition based on the source layer 4 port of a packet using a single keyword, a numeric notation, or a numeric range notation. DiffServ Policy Creation Beginning in Privileged Exec mode, use the following commands to configure DiffServ policies and view related information. CLI Command Description configure Enter global configuration mode. policy-map policy-name in Create a new DiffServ policy for ingress traffic and enter Policy Map Configuration mode for the policy. exit Exit to Privilege Exec mode. show policy-map Displays all configuration information for the specified policy. show policy-map interface in Displays policy-oriented statistics information for the specified interface. Configuring Differentiated Services 1119 DiffServ Policy Attributes Configuration Beginning in Privilege Exec mode, use the following commands to configure policy attributes and view related information. CLI Command Description configure Enter global configuration mode. policy-map policy-map-name Enter Policy Map Configuration mode for the specified policy. class class-name Create an instance of a class definition within the specified policy for the purpose of defining treatment of the traffic class through subsequent policy attribute statements. Also enters PolicyClass-Map Configuration mode for the policy-classmap instance. assign-queue queue-id Modify the queue ID (range: 0–6) to which the associated traffic stream is assigned. police-simple {datarate burstsize conform-action {drop | set-cos-transmit cos | set-prectransmit cos | set-dscptransmit dscpval | transmit} [violateaction {drop | set-costransmit cos | set-prectransmit cos | set-dscptransmit dscpval | transmit}]} Establish the traffic policing style for the specified class. The simple form of the police command uses a single data rate and burst size, resulting in two outcomes: conform and nonconform. • datarate — Data rate in kilobits per second (kbps). (Range: 1–4294967295) • burstsize — Burst size in Kbps (Range: 1–128) • conform action — Indicates what happens when the packet is conforming to the policing rule: it could be dropped, it could have its COS modified, it could have its IP precedence modified, or it could have its DSCP modified. The same actions are available for packets that do not conform to the policing rule. • cos — Class of Service value. (Range: 0–7) • dscpval — DSCP value. (Range: 0–63 or a keyword from this list, af11, af12, af13, af21, af22, af23, af31, af32, af33, af41, af42, af43, be, cs0, cs1, cs2, cs3, cs4, cs5, cs6, cs7, ef) 1120 Configuring Differentiated Services CLI Command Description conform-color class-map-name Specify the color class for color-aware policing. [exceed-color class-map-name] The action for the policy-class-map instance must be set to police-simple before issuing the conformcolor command. drop Specify that all packets for the associated traffic stream are to be dropped at ingress. mark cos cos-value Mark all packets for the associated traffic stream with the specified class of service value (range: 0–7) in the priority field of the 802.1p header. mark ip-dscp dscp-value Mark all packets for the associated traffic stream with the specified IP DSCP value. mark ip-precedence value Mark all packets for the associated traffic stream with the specified IP precedence value (range: 0–7). mirror interface | redirect Use mirror to mirror all packets for the associated traffic stream that matches the defined class to the specified destination port or LAG. interface Use redirect to specify that all incoming packets for the associated traffic stream are redirected to the specified destination port or LAG. exit Exit to Policy-Map Config mode. exit Exit to Global Config mode. exit Exit to Privilege Exec mode. show policy-map policy-map- Displays configuration information for the specified policy. name Configuring Differentiated Services 1121 DiffServ Service Configuration Beginning Privilege Exec mode, use the following commands to associate a policy with an interface and view related information. CLI Command Description configure Enter Global Configuration mode. service-policy {in | out} policy-map-name Attach a policy to an interface in the inbound or outbound direction. This command can be used in either Global Configuration mode (for all system interfaces) or Interface Configuration mode (for a specific interface). exit Exit to Privilege Exec mode. show diffserv service brief [in | out] Display all interfaces in the system to which a DiffServ policy has been attached. show diffserv service interface interface {in | out} Display policy service information for the specified interface, where interface is replaced by gigabitethernet unit/slot/port, tengigabitethernet unit/slot/port, or port-channel portchannel number. show service-policy {in | out} Display a summary of policy-oriented statistics information for all interfaces. 1122 Configuring Differentiated Services DiffServ Configuration Examples This section contains the following examples: • Providing Subnets Equal Access to External Network • DiffServ for VoIP Providing Subnets Equal Access to External Network This example shows how a network administrator can provide equal access to the Internet (or other external network) to different departments within a company. Each of four departments has its own Class B subnet that is allocated 25% of the available bandwidth on the port accessing the Internet. Figure 39-17. DiffServ Internet Access Example Network Diagram Internet Port 1/0/5 Outbound Source IP: 172.16.10.0 255.255.255.0 Layer 3 Switch 1/0/1 1/0/2 1/0/3 Finance 1/0/4 Development Marketing Source IP: 172.16.20.0 255.255.255.0 Test Source IP: 172.16.40.0 255.255.255.0 Source IP: 172.16.30.0 255.255.255.0 Configuring Differentiated Services 1123 The following commands show how to configure the DiffServ example depicted in Figure 39-17. 1 Enable DiffServ operation for the switch. console#config console(config)#diffserv 2 Create a DiffServ class of type all for each of the departments, and name them. Also, define the match criteria—Source IP address—for the new classes. console(config)#class-map match-all finance_dept console(config-classmap)#match srcip 172.16.10.0 255.255.255.0 console(config-classmap)#exit console(config)#class-map match-all marketing_dept console(config-classmap)#match srcip 172.16.20.0 255.255.255.0 console(config-classmap)#exit console(config)#class-map match-all test_dept console(config-classmap)#match srcip 172.16.30.0 255.255.255.0 console(config-classmap)#exit console(config)#class-map match-all development_dept console(config-classmap)#match srcip 172.16.40.0 255.255.255.0 console(config-classmap)#exit 3 Create a DiffServ policy for inbound traffic named internet_access, adding the previously created department classes as instances within this policy. This policy uses the assign-queue attribute to put each department's traffic on a different egress queue. This is how the DiffServ inbound policy connects to the CoS queue settings established below. console(config)#policy-map internet_access in console(config-policy-map)#class finance_dept console(config-policy-classmap)#assign-queue 1 console(config-policy-classmap)#exit console(config-policy-map)#class marketing_dept console(config-policy-classmap)#assign-queue 2 console(config-policy-classmap)#exit console(config-policy-map)#class test_dept console(config-policy-classmap)#assign-queue 3 console(config-policy-classmap)#exit 1124 Configuring Differentiated Services console(config-policy-map)#class development_dept console(config-policy-classmap)#assign-queue 4 console(config-policy-classmap)#exit console(config-policy-map)#exit 4 Attach the defined policy to Gigabit Ethernet interfaces 1/0/1 through 1/0/4 in the inbound direction console(config)#interface gigabitethernet 1/0/1 console(config-if-Gi1/0/1)#service-policy in internet_access console(config-if-Gi1/0/1)#exit console(config)#interface gigabitethernet 1/0/2 console(config-if-Gi1/0/2)#service-policy in internet_access console(config-if-Gi1/0/2)#exit console(config)#interface gigabitethernet 1/0/3 console(config-if-Gi1/0/3)#service-policy in internet_access console(config-if-Gi1/0/3)#exit console(config)#interface gigabitethernet 1/0/4 console(config-if-Gi1/0/4)#service-policy in internet_access console(config-if-Gi1/0/4)#exit 5 Set the CoS queue configuration for the (presumed) egress Gigabit Ethernet interface 1/0/1 such that each of queues 1, 2, 3 and 4 get a minimum guaranteed bandwidth of 25%. All queues for this interface use weighted round robin scheduling by default. The DiffServ inbound policy designates that these queues are to be used for the departmental traffic through the assign-queue attribute. It is presumed that the switch will forward this traffic to Gigabit Ethernet interface 1/0/1 based on a normal destination address lookup for internet traffic. console(config)#interface gigabitethernet 1/0/5 console(config-if-Gi1/0/5)#cos-queue min-bandwidth 0 25 25 25 25 0 0 console(config-if-Gi1/0/5)#exit console(config)#exit Configuring Differentiated Services 1125 DiffServ for VoIP One of the most valuable uses of DiffServ is to support Voice over IP (VoIP). VoIP traffic is inherently time-sensitive: for a network to provide acceptable service, a guaranteed transmission rate is vital. This example shows one way to provide the necessary quality of service: how to set up a class for UDP traffic, have that traffic marked on the inbound side, and then expedite the traffic on the outbound side. The configuration script is for Router 1 in the accompanying diagram: a similar script should be applied to Router 2. Figure 39-18. DiffServ VoIP Example Network Diagram ` Layer 3 Switch Operating as Router 1 Port 1/0/2 Port 1/0/3 Internet Layer 3 Switch Operating as Router 2 ` 1126 Configuring Differentiated Services The following commands show how to configure the DiffServ example depicted in Figure 39-18. 1 Set queue 6 on all ports to use strict priority mode. This queue shall be used for all VoIP packets. Activate DiffServ for the switch. console#config console(config)#cos-queue strict 6 console(config)#diffserv 2 Create a DiffServ classifier named class_voip and define a single match criterion to detect UDP packets. The class type match-all indicates that all match criteria defined for the class must be satisfied in order for a packet to be considered a match. console(config)#class-map match-all class_voip console(config-classmap)#match protocol udp console(config-classmap)#exit 3 Create a second DiffServ classifier named class_ef and define a single match criterion to detect a DiffServ code point (DSCP) of EF (expedited forwarding). This handles incoming traffic that was previously marked as expedited elsewhere in the network. console(config)#class-map match-all class_ef console(config-classmap)#match ip dscp ef console(config-classmap)#exit 4 Create a DiffServ policy for inbound traffic named pol_voip, then add the previously created classes 'class_ef' and 'class_voip' as instances within this policy. This policy handles incoming packets already marked with a DSCP value of EF (per class_ef definition), or marks UDP packets (per the class_voip definition) with a DSCP value of EF. In each case, the matching packets are assigned internally to use queue 6 of the egress port to which they are forwarded. console(config)#policy-map pol_voip in console(config-policy-map)#class class_ef console(config-policy-classmap)#assign-queue 6 console(config-policy-classmap)#exit console(config-policy-map)#class class_voip console(config-policy-classmap)#mark ip-dscp ef console(config-policy-classmap)#assign-queue 6 Configuring Differentiated Services 1127 console(config-policy-classmap)#exit console(config-policy-map)#exit 5 Attach the defined policy to an inbound service interface. console(config)#interface gigabitethernet 1/0/1 console(config-if-Gi1/0/1)#service-policy in pol_voip console(config-if-Gi1/0/1)#exit console(config)#exit 1128 Configuring Differentiated Services Configuring Class-of-Service 40 This chapter describes how to configure the Class-of-Service (CoS) feature. The CoS queueing feature lets you directly configure certain aspects of switch queueing. This provides the desired QoS behavior for different types of network traffic when the complexities of DiffServ are not required. The priority of a packet arriving at an interface can be used to steer the packet to the appropriate outbound CoS queue through a mapping table. CoS queue characteristics that affect queue mapping, such as minimum guaranteed bandwidth, transmission rate shaping, etc., are user-configurable at the queue (or port) level. The topics covered in this chapter include: • CoS Overview • Default CoS Values • Configuring CoS (Web) • Configuring CoS (CLI) • CoS Configuration Example CoS Overview The CoS feature lets you give preferential treatment to certain types of traffic over others. To set up this preferential treatment, you can configure the ingress ports, the egress ports, and individual queues on the egress ports to provide customization that suits your environment. The level of service is determined by the egress port queue to which the traffic is assigned. When traffic is queued for transmission, the rate at which it is serviced depends on how the queue is configured and possibly the amount of traffic present in other queues for that port. Some traffic is classified for service (i.e., packet marking) before it arrives at the switch. If you decide to use these classifications, you can map this traffic to egress queues by setting up a CoS Mapping table. Configuring Class-of-Service 1129 Each ingress port on the switch has a default priority value (set by configuring VLAN Port Priority in the Switching sub-menu) that determines the egress queue its traffic gets forwarded to. Packets that arrive without a VLAN user priority, or packets from ports you’ve identified as “untrusted,” get forwarded according to this default. What Are Trusted and Untrusted Port Modes? Ports can be configured in “trusted” mode or “untrusted” mode with respect to ingress traffic. Ports in Trusted Mode When a port is configured in trusted mode, the system accepts at face value a priority designation encoded within packets arriving on the port. You can configure ports to trust priority designations based on one of the following fields in the packet header: • 802.1 Priority: values 0–7 • IP DSCP: values 0–63 A mapping table associates the designated field values in the incoming packet headers with a traffic class priority (actually a CoS traffic queue). Ports in Untrusted Mode If you configure an ingress port in untrusted mode, the system ignores any priority designations encoded in incoming packets, and instead sends the packets to a traffic queue based on the ingress port’s default priority. How Is Traffic Shaping Used on Egress Traffic? For unit/slot/port interfaces, you can specify a traffic shaping rate for the port (in Kbps) for egress traffic. The traffic shaping rate specifies an upper limit of the transmission bandwidth used. Once the traffic shaping rate has been reached, frames that exceeded the limit remain queued for transmission until the next scheduling slot. 1130 Configuring Class-of-Service How Are Traffic Queues Defined? For each queue, you can specify: • Minimum bandwidth guarantee—A percentage of the port’s maximum negotiated bandwidth reserved for the queue. Unreserved bandwidth can be utilized by lower-priority queues. If the sum of the minimum bandwidth is 100%, then there is no unreserved bandwidth and no sharing of bandwidth is possible. • Scheduler type—strict/weighted: – Strict priority scheduling gives an absolute priority based on CoS queue number, with traffic in the highest numbered queue sent first, then the next lowest numbered queue, and so on. Weighted queues are serviced after all strict priority queues have been serviced. – Weighted scheduling selects packets for transmission with a fixed weighting equal to the CoS queue number plus one. The weighted scheduler measures bandwidth based upon bytes vs. packet counts, offering a better granularity of scheduling. For example, if CoS queues 0, 1, and 2 have an equal offered load toward a congested output port, CoS queue 2 will receive 3/6 of the bandwidth, CoS queue 1 will receive 2/6 of the bandwidth, and CoS queue 0 will receive 1/6 of the bandwidth. The minimum bandwidth setting can be used to override the strict priority and weighted settings. The highest numbered strict priority queue will receive no more bandwidth than 100 percent minus the sum of the minimum bandwidths percentages assigned to the other queues. If used, it is recommended that minimum bandwidth percentages only be high enough to ensure a minimum level of service for any queue; i.e., the sum of the minimum bandwidth percentages is a small fraction of 100%. This ensures that the system can respond to bursts in traffic. Setting the minimum bandwidth percentages such that they sum to 100% effectively sets the scheduler such that sharing of bandwidth is disabled. Which Queue Management Methods Are Supported? The switch supports the following methods, configurable per-interfacequeue, for determining which packets are dropped when the queue is full: • Taildrop—Any packet forwarded to a full queue is dropped regardless of its priority. Configuring Class-of-Service 1131 • Weighted Random Early Detection (WRED)—Drops packets queued for transmission selectively based their drop precedence level. For each of four drop precedence levels on each WRED-enabled interface queue, you can configure the following parameters: – Minimum Threshold: A percentage of the total queue size below which no packets of the selected drop precedence level are dropped. – Maximum Threshold: A percentage of the total queue size above which all packets of the selected drop precedence level are dropped. – Drop Probability: When the queue depth is between the minimum and maximum thresholds, this value provides a scaling factor for increasing the number of packets of the selected drop precedence level that are dropped as the queue depth increases. The drop probability supports configuration in the range of 0 to 10%, and the discrete values 25%, 50%, and 75%. Values not listed are truncated to the next lower value in hardware. CoS Queue Usage CoS queue 7 is reserved by the system and is not assignable. It is generally recommended that the administrator utilize CoS queues 0 to 3, as CoS queues 4-6 may be used by the system for other types of system traffic, for example, routing protocol PDU handling. Default CoS Values Table 40-1 shows the global default values for CoS. Table 40-1. CoS Global Defaults Parameter Default Value Trust Mode 802.1p 802.1p CoS value to queue mapping 802.1p CoS Queue 0, 3 1 1, 2 0 4, 5 2 6, 7 3 1132 Configuring Class-of-Service Table 40-1. CoS Global Defaults Parameter Default Value IP DSCP value to queue mapping IP DSCP Queue 0–7, 24–31 1 8–23 0 32–47 2 48–63 3 Interface Shaping Rate 0 Kbps Minimum Bandwidth 0% Scheduler Type Weighted Queue Management Type Taildrop Drop Precedence Level 1 WRED Decay Exponent 9 WRED Minimum Threshold 40 WRED Maximum Threshold 100 WRED Drop Probability Scale 10 Configuring CoS (Web) This section provides information about the OpenManage Switch Administrator pages for configuring and monitoring CoS features on a PowerConnect 7000 Series switch. For details about the fields on a page, click at the top of the page. Mapping Table Configuration Use the Mapping Table Configuration page to define how class of service is assigned to a packet. To display the page, click Quality of Service → Class of Service → Mapping Table Configuration in the navigation panel. CoS(802.1P) is the default mode, so this is the page that displays when Mapping Table Configuration is selected from the Class of Service menu page. Configuring Class-of-Service 1133 Figure 40-1. Mapping Table Configuration — CoS (802.1P) 1134 Configuring Class-of-Service To access the DSCP Queue Mapping Table, click the DSCP Queue Mapping Table link at the top of the page. Figure 40-2. DSCP Queue Mapping Table Configuring Class-of-Service 1135 Interface Configuration Use the Interface Configuration page to define the interface shaping rate for egress packets on an interface and the decay exponent for WRED queues defined on the interface. Each interface CoS parameter can be configured globally or per-port. A global configuration change is applied to all interfaces in the system. To display the Interface Configuration page, click Quality of Service → Class of Service → Interface Configuration in the navigation panel. Figure 40-3. Interface Configuration 1136 Configuring Class-of-Service Interface Queue Configuration Use the Interface Queue Configuration page to configure egress queues on interfaces. The settings you configure control the amount of bandwidth the queue uses, the scheduling method, and the queue management method. The configuration process is simplified by allowing each CoS queue parameter to be configured globally or per-port. A global configuration change is applied to the same queue ID on all ports in the system. To display the Interface Queue Configuration page, click Quality of Service → Class of Service → Interface Queue Configuration in the navigation panel. Figure 40-4. Interface Queue Configuration Configuring Class-of-Service 1137 To access the Interface Queue Status page, click the Show All link at the top of the page. Interface Queue Drop Precedence Configuration Use the Interface Queue Drop Precedence Configuration page to configure thresholds and scaling values for each of four drop precedence levels on a WRED-enabled interface queue. The settings you configure control the minimum and maximum thresholds and a drop probability scaling factor for the selected drop precedence level. These parameters can be applied to each drop precedence level on a perinterface-queue basis, or can be set globally for the same drop precedence level and queue ID on all interfaces. To display the Interface Queue Drop Precedence Configuration page, click Quality of Service → Class of Service → Interface Queue Drop Precedence Configuration in the navigation panel. 1138 Configuring Class-of-Service Figure 40-5. Interface Queue Drop Precedence Configuration To access the Interface Queue Drop Precedence Status page, click the Show All link at the top of the page. Configuring Class-of-Service 1139 Configuring CoS (CLI) This section provides information about the commands you use to configure CoS settings on the switch. For more information about the commands, see the PowerConnect 7000 Series CLI Reference Guide at support.dell.com/manuals. Mapping Table Configuration Beginning in Privileged Exec mode, use the following commands in to configure the CoS mapping tables. CLI Command Description configure Enter Global Configuration mode. interface interface Enter Interface Configuration mode, where interface is replaced by gigabitethernet unit/slot/port, tengigabitethernet unit/slot/port, or port-channel port-channel number. classofservice dotlp-mapping Map an 802.1p priority to an internal traffic class for a switch. You can also use this command in Global Configuration mode to configure the same mappings on all interfaces. classofservice trust {dot1p | ip-dscp | untrusted} Set the class of service trust mode of an interface. exit Exit to Global Config mode. exit Exit to Privilege Exec mode. show classofservice dotlpmapping Display the current Dot1p (802.1p) priority mapping to internal traffic classes for a specific interface. show classofservice ip-dscpmapping Display the current IP DSCP mapping to internal traffic classes for a specific interface. show classofservice trust Display the current trust mode setting for a specific interface. priority 1140 Configuring Class-of-Service CoS Interface Configuration Commands Beginning in Privileged Exec mode, use the following commands in to configure the traffic shaping and WRED exponent values for an interface. CLI Command Description configure Enter Global Configuration mode. interface interface Enter Interface Configuration mode, where interface is replaced by gigabitethernet unit/slot/port, tengigabitethernet unit/slot/port, or port-channel port-channel number. traffic-shape bw kbps Sets the upper limit on how much traffic can leave a port. The bw variable represents the shaping bandwidth value from 64 to 4294967295 kbps. random-detect exponential- Configure the WRED decay exponent (range: 0–15) weighting-constant exponent for the interface. The weighting constant exponent determines how much of the previous average queue length sample is added to the current average queue length. A value of 0 indicates that no weight is given to the previous sample and only the instantaneous rate is used. A value of 1 indicates that 1/2 of the difference between the instantaneous value and the previous value is added to the current value; a value of 2 implies that 1/4 of the difference is added, 3 implies 1/8 of the difference is added, etc. Interface Queue Configuration Beginning in Privileged Exec mode, use the following commands in to configure and view CoS interface queue settings. CLI Command Description configure Enter Global Configuration mode. interface interface Enter Interface Configuration mode, where interface is replaced by gigabitethernet unit/slot/port, tengigabitethernet unit/slot/port., or port-channel portchannel number. Configuring Class-of-Service 1141 CLI Command Description cos-queue min-bandwidth Specify the minimum transmission bandwidth (range: 0-100% in 1% increments) for each interface queue. cos-queue strict queue-id Activate the strict priority scheduler mode for each specified queue. The queue-id value ranges from 0 to 6. queue-id cos-queue random-detect Set the queue management type for the specified queue to WRED. The no version of this command resets the value to taildrop. exit Exit to Global Config mode. exit Exit to Privilege Exec mode. show interfaces cos-queue Display the class-of-service queue configuration for a specified interface or all interfaces. bw 1142 Configuring Class-of-Service Configuring Interface Queue Drop Probability Beginning in Privileged Exec mode, use the following commands in to configure characteristics of the drop probability and view related settings. The drop probability supports configuration in the range of 0 to 10%, and the discrete values 25%, 50%, and 75%. Values not listed are truncated to the next lower value in hardware. CLI Command Description configure Enter Global Configuration mode. interface interface Enter Interface Configuration mode, where interface is replaced by gigabitethernet unit/slot/port, tengigabitethernet unit/slot/port, or port-channel port-channel number. random-detect queue-parms queue-id [queue-id...] minthresh min1 min2 min3 min4 max-thresh max1 max2 max3 max4 drop-prob prob1 prob2 Configure the maximum and minimum thresholds for one or more queue IDs on a WRED-enabled interface queue. prob3 prob4 You can also use this command in Global Configuration mode to configure the same parameters for one or more queues on all interfaces. exit Exit to Global Config mode. exit Exit to Privilege Exec mode. show interfaces random-detect Display WRED parameters for an interface or all interfaces. Configuring Class-of-Service 1143 CoS Configuration Example Figure 40-6 illustrates the network operation as it relates to CoS mapping and queue configuration. Four packets arrive at the ingress port te1/0/10 in the order A, B, C, and D. port te1/0/10 is configured to trust the 802.1p field of the packet, which serves to direct packets A, B, and D to their respective queues on the egress port. These three packets utilize the 802.1p to CoS Mapping Table for port te1/0/10. In this example, the 802.1p user priority 3 is configured to send the packet to queue 5 instead of the default queue 3. Since packet C does not contain a VLAN tag, the 802.1p user priority does not exist, so port te1/0/10 relies on its default port priority (2) to direct packet C to egress queue 1. Figure 40-6. CoS Mapping and Queue Configuration 1144 Configuring Class-of-Service Continuing this example, the egress port te1/0/8 is configured for strict priority on queue 6, and a weighted scheduling scheme is configured for queues 5-0. Assuming queue 5 has a higher minimum bandwidth than queue 1 (relative bandwidth values are shown as a percentage, with 0% indicating the bandwidth is not guaranteed), the queue service order is 6 followed by 5 followed by 1. Assuming each queue transmits all packets shown in the diagram, the packet transmission order as seen on the network out of port te1/0/8 is B, A, D, C. Thus, packet B, with its strict priority scheduling, is transmitted ahead of the other packets at the egress port. The following commands configure port 10 (ingress interface) and port 8 (egress interface). 1 Configure the Trust mode for port 10. console#config console(config)#interface gigabitethernet 1/0/10 console(config-if-Gi1/0/10)#classofservice trust dot1p 2 For port 10, configure the 802.1p user priority 3 to send the packet to queue 5 instead of the default queue (queue 3). console(config-if-Gi1/0/10)#classofservice dot1pmapping 3 5 3 For port 10, specify that untagged VLAN packets should have a default priority of 2. console(config-if-Gi1/0/10)#vlan priority 2 console(config-if-Gi1/0/10)#exit 4 For port 8, the egress port, configure a weighted scheduling scheme for queues 5-0. console(config)#interface gigabitethernet 1/0/8 console(config-if-Gi1/0/8)#cos-queue minbandwidth 0 0 5 5 10 20 40 5 Configure port 8 to have strict priority on queue 6: console(config-if-Gi1/0/8)#cos-queue strict 6 To configure the CoS queues for lossless traffic when transporting iSCSI traffic, set the lossless traffic class to have a one-to-one mapping with the priority value. The following example illustrates how to change the dot1p mapping from the switch defaults to support lossless transport of frames on Configuring Class-of-Service 1145 CoS queue 4, with a 50% minimum bandwidth guarantee. Lossless traffic classes generally use the default WRR scheduling mode as opposed to strict priority, to avoid starving other traffic. For example, the following commands assign user priority 4 to CoS queue 4 and reserve 50% of the scheduler bandwidth to CoS queue 4. classofservice dot1p-mapping 4 4 cos-queue min-bandwidth 0 0 0 0 50 0 0 1146 Configuring Class-of-Service Configuring Auto VoIP 41 Voice over Internet Protocol (VoIP) allows you to make telephone calls using a computer network over a data network like the Internet. With the increased prominence of delay-sensitive applications (voice, video, and other multimedia applications) deployed in networks today, proper QoS configuration will ensure high-quality application performance. The Auto VoIP feature is intended to provide an easy classification mechanism for voice packets so that they can be prioritized above data packets in order to provide better QoS. Because Auto VoIP is limited to 16 sessions, Voice VLAN is the preferred solution for enterprises wishing to deploy a large scale voice service. The topics covered in this chapter include: • Auto VoIP Overview • Default Auto VoIP Values • Configuring Auto VoIP (Web) • Configuring Auto VoIP (CLI) Auto VoIP Overview The Auto VoIP feature explicitly matches VoIP streams in Ethernet switches and provides them with a better class of service than ordinary traffic. If you enable the Auto VoIP feature on an interface, the interface scans incoming traffic for the following call-control protocols: • Session Initiation Protocol (SIP) • H.323 • Skinny Client Control Protocol (SCCP) When a call-control protocol is detected the switch assigns the traffic in that session to the highest CoS queue, which is generally used for time-sensitive traffic. Configuring Auto VoIP 1147 Auto-VoIP is limited to 16 sessions and makes use of the switch CPU to classify traffic. It is preferable to use the Voice VLAN feature in larger enterprise environments as it uses the switching silicon to classify voice traffic onto a VLAN. How Does Auto-VoIP Use ACLs? Auto-VoIP borrows ACL lists from the global system pool. ACL lists allocated by Auto-VoIP reduce the total number of ACLs available for use by the network operator. Enabling Auto-VoIP uses one ACL list to monitor for VoIP sessions. Each monitored VoIP session utilizes two rules from an additional ACL list. This means that the maximum number of ACL lists allocated by Auto-VoIP is two. Default Auto VoIP Values Table 41-1 shows the global default value for Auto VoIP. Table 41-1. Auto VoIP Global Defaults Parameter Default Value Auto VoIP Disabled 1148 Configuring Auto VoIP Configuring Auto VoIP (Web) This section provides information about the OpenManage Switch Administrator pages for configuring and monitoring Auto VoIP features on a PowerConnect 7000 Series switch. For details about the fields on a page, click at the top of the page. Auto VoIP Global Configuration Use the Global Configuration page to enable or disable Auto VoIP on all interfaces. To display the Auto VoIP Global Configuration page, click Quality of Service → Auto VoIP → Global Configuration in the navigation menu. Figure 41-1. Auto VoIP Global Configuration Auto VoIP Interface Configuration Use the Interface Configuration page to enable or disable Auto VoIP on a particular interface. To display the Interface Configuration page, click Quality of Service → Auto VoIP → Interface Configuration in the navigation menu. Configuring Auto VoIP 1149 Figure 41-2. Auto VoIP Interface Configuration 1150 Configuring Auto VoIP To display summary Auto VoIP configuration information for all interfaces, click the Show All link at the top of the page. Figure 41-3. Auto VoIP Configuring Auto VoIP 1151 Configuring Auto VoIP (CLI) This section provides information about the commands you use to configure Auto VoIP settings on the switch. For more information about the commands, see the PowerConnect 7000 Series CLI Reference Guide at support.dell.com/manuals. Mapping Table Configuration Beginning in Privileged Exec mode, use the following commands in to enable Auto VoIP and view its configuration. CLI Command Description configure Enter Global Configuration mode. switchport voice detect auto Enable the VoIP Profile on all the interfaces of the switch. You can also enter Interface Configuration mode and use the same command to enable it on a specific interface. exit Exit to Global Configuration Exec mode. exit Exit to Privilege Exec mode. show switchport voice Show the status of Auto-VoIP on all interfaces or on an interface, if one is specified. 1152 Configuring Auto VoIP 42 Managing IPv4 and IPv6 Multicast This chapter describes how to configure and monitor layer 3 multicast features for IPv4 and IPv6, including global IP and IPv6 multicast features as well as multicast protocols, including IGMP, DVMRP, and PIM for IPv4 and MLD and PIM for IPv6. The topics covered in this chapter include: • L3 Multicast Overview • Default L3 Multicast Values • Configuring General IPv4 Multicast Features (Web) • Configuring IPv6 Multicast Features (Web) • Configuring IGMP and IGMP Proxy (Web) • Configuring MLD and MLD Proxy (Web) • Configuring PIM for IPv4 and IPv6 (Web) • Configuring DVMRP (Web) • Configuring L3 Multicast Features (CLI) • L3 Multicast Configuration Examples L3 Multicast Overview IP Multicasting enables a network host (or multiple hosts) to send an IP datagram to multiple destinations simultaneously. The initiating host sends each multicast datagram only once to a destination multicast group address, and multicast routers forward the datagram only to hosts who are members of the multicast group. Multicast enables efficient use of network bandwidth because each multicast datagram needs to be transmitted only once on each network link, regardless of the number of destination hosts. Multicasting contrasts with IP unicasting, which sends a separate datagram to each recipient host. The IP routing protocols can route multicast traffic, but the IP multicast protocols handle the multicast traffic more efficiently with better use of network bandwidth. Managing IPv4 and IPv6 Multicast 1153 Applications that often send multicast traffic include video or audio conferencing, Whiteboard tools, stock distribution tickers, and IP-based television (IP/TV). What Is IP Multicast Traffic? IP multicast traffic is traffic that is destined to a host group. Host groups are identified by class D IP addresses, which range from 224.0.0.0 to 239.255.255.255. When a packet with a broadcast or multicast destination IP address is received, the switch will forward a copy into each of the remaining network segments in accordance with the IEEE MAC Bridge standard. Eventually, the packet is made accessible to all nodes connected to the network. This approach works well for broadcast packets that are intended to be seen or processed by all connected nodes. In the case of multicast packets, however, this approach could lead to less efficient use of network bandwidth, particularly when the packet is intended for only a small number of nodes. Packets will be flooded into network segments where no node has any interest in receiving the packet. The L3 multicast features on the switch help to ensure that only the hosts in the multicast group receive the multicast traffic for that group. Multicast applications send one copy of a packet, and address it to a group of receivers (Multicast Group Address) rather than to a single receiver (unicast address). Multicast depends on the network to forward the packets to only those networks and hosts that need to receive them. 1154 Managing IPv4 and IPv6 Multicast What Multicast Protocols Does the Switch Support? Multicast protocols are used to deliver multicast packets from one source to multiple receivers. Table 42-1 summarizes the multicast protocols that the switch supports. Table 42-1. Multicast Protocol Support Summary Protocol IPv4 or IPv6 For Communication Between IGMP IPv4 Host-to-L3 switch/router IGMP Proxy IPv4 Host-to-L3 switch/router MLD IPv6 Host-to-L3 switch/router MLD Proxy IPv6 Host-to-L3 switch/router PIM-SM IPv4 and IPv6 L3-switch/router-to-L3 switch/router PIM-DM IPv4 and IPv6 L3-switch/router-to-L3 switch/router DVMRP IPv4 L3-switch/router-to-L3 switch/router What Are the Multicast Protocol Roles? Hosts must have a way to identify their interest in joining any particular multicast group, and routers must have a way to collect and maintain group memberships. These functions are handled by the IGMP protocol in IPv4. In IPv6, multicast routers use the Multicast Listener Discover (MLD) protocol to maintain group membership information. Multicast routers must also be able to construct a multicast distribution tree that enables forwarding multicast datagrams only on the links that are required to reach a destination group member. Protocols such as DVMRP, and PIM handle this function. IGMP and MLD are multicast group discovery protocols that are used between the clients and the local multicast router. PIM-SM, PIM-DM, and DVMRP are multicast routing protocols that are used across different subnets, usually between the local multicast router and remote multicast router. Managing IPv4 and IPv6 Multicast 1155 When Is L3 Multicast Required on the Switch? Use the IPv4/IPv6 multicast feature on PowerConnect 7000 Series switches to route multicast traffic between VLANs on the switch. If all hosts connected to the switch are on the same subnet, there is no need to configure the IP/IPv6 multicast feature. If the switch does not require L3 routing, you can use IGMP snooping or MLD snooping to manage port-based multicast group membership. For more information, see "What Is IGMP Snooping?" on page 705 and "What Is MLD Snooping?" on page 707. If the local network does not have a multicast router, you can configure the switch to act as the IGMP querier. For more information, see "IGMP Snooping Querier" on page 706. If the switch is configured as a L3 switch and handles inter-VLAN routing through static routes, OSPF, or RIP, and multicast traffic is transmitted within the network, enabling and configuring L3 multicast routing on the switch is recommended. Determining Which Multicast Protocols to Enable IGMP is required on any multicast router that serves IPv4 hosts. IGMP is not required on inter-router links. MLD is required on any router that serves IPv6 hosts. MLD is not required on inter-router links. PIM-DM, PIM-SM, and DVMRP are multicast routing protocols that help determine the best route for IP (PIM and DVMRP) and IPv6 (PIM) multicast traffic. For more information about when to use PIM-DM, see "Using PIM-DM as the Multicast Routing Protocol" on page 1168. For more information about when to use PIM-SM, see "Using PIM-SM as the Multicast Routing Protocol" on page 1159. For more information about when to configure DVMRP, see "Using DVMRP as the Multicast Routing Protocol" on page 1170. Unless specifically required, IGMP/MLD snooping should be disabled on L3 multicast routers. What Is the Multicast Routing Table? Multicast capable/enabled routers forward multicast packets based on the routes in the Multicast Routing Information Base (MRIB). These routes are created in the MRIB during the process of building multicast distribution trees by the Multicast Protocols running on the router. Different IP Multicast routing protocols use different techniques to construct these multicast distribution trees. 1156 Managing IPv4 and IPv6 Multicast What Is IGMP? The Internet Group Management Protocol (IGMP) is used by IPv4 systems (hosts, L3 switches, and routers) to report their IP multicast group memberships to any neighboring multicast routers. The PowerConnect 7000 Series switch performs the multicast router role of the IGMP protocol, which means it collects the membership information needed by the active multicast routing protocol. The PowerConnect 7000 Series switch also supports IGMP Version 3. Version 3 adds support for source filtering, which is the ability for a system to report interest in receiving packets only from specific source addresses, as required to support Source-Specific Multicast [SSM], or from all but specific source addresses, sent to a particular multicast address. Version 3 is designed to be interoperable with Versions 1 and 2. Understanding IGMP Proxy IGMP proxy enables a multicast router to learn multicast group membership information and forward multicast packets based upon the group membership information. The IGMP Proxy is capable of functioning only in certain topologies that do not require Multicast Routing Protocols (i.e., DVMRP, PIM-DM, and PIM-SM) and have a tree-like topology, as there is no support for features like reverse path forwarding (RPF) to correct packet route loops. The proxy contains many downstream interfaces and a unique upstream interface explicitly configured. It performs the host side of the IGMP protocol on its upstream interface and the router side of the IGMP protocol on its downstream interfaces. The IGMP proxy offers a mechanism for multicast forwarding based only on IGMP membership information. The router must decide about forwarding packets on each of its interfaces based on the IGMP membership information. The proxy creates the forwarding entries based on the membership information and adds it to the multicast forwarding cache (MFC) in order not to make the forwarding decision for subsequent multicast packets with same combination of source and group. Managing IPv4 and IPv6 Multicast 1157 What Is MLD? Multicast Listener Discovery (MLD) protocol enables IPv6 routers to discover the presence of multicast listeners, the hosts that wish to receive the multicast data packets, on its directly-attached interfaces. The protocol specifically discovers which multicast addresses are of interest to its neighboring nodes and provides this information to the active multicast routing protocol that makes decisions on the flow of multicast data packets. The Multicast router sends General Queries periodically to request multicast address listeners information from systems on an attached network. These queries are used to build and refresh the multicast address listener state on attached networks. Multicast listeners respond to these queries by reporting their multicast addresses listener state and their desired set of sources with Current-State Multicast address Records in the MLD2 Membership Reports. The Multicast router also processes unsolicited Filter-Mode-Change records and Source-List-Change Records from systems that want to indicate interest in receiving or not receiving traffic from particular sources. The PowerConnect implementation of MLD v2 supports the multicast router portion of the protocol (i.e., not the listener portion). It is backwardcompatible with MLD v1. 1158 Managing IPv4 and IPv6 Multicast What Is PIM? The Protocol Independent Multicast protocol is a simple, protocolindependent multicast routing protocol. PIM uses an existing unicast routing table and a Join/Prune/Graft mechanism to build a tree. PowerConnect 7000 Series switches support two types of PIM: sparse mode (PIM-SM) and dense mode (PIM-DM). PIM-SM is most effective in networks with a sparse population of multicast receivers. In contrast, PIM-DM is most effective in networks with densely populated multicast receivers. In other words, PIM-DM can be used if the majority of network hosts request to receive a multicast stream, while PIMSM might be a better choice in networks in which a small percentage of network hosts, located throughout the network, wish to receive the multicast stream. Using PIM-SM as the Multicast Routing Protocol PIM-SM is used to efficiently route multicast traffic to multicast groups that may span wide area networks and where bandwidth is constrained. PIM-SM uses shared trees by default and implements source-based trees for efficiency. PIM-SM assumes that no hosts want the multicast traffic unless they specifically ask for it. It initially creates a shared distribution tree centered on a defined “rendezvous point” (RP) through which source traffic is relayed to the ultimate receiver. Multicast traffic sources first send the multicast data to the RP, which in turn sends the data down the shared tree to the receivers. Shared trees centered on an RP do not necessarily provide the shortest or most optimal path. In such cases, a PowerConnect PIM-SM router adjacent to the host switches to the shortest path upon seeing the very first multicast data packet. Many IP multicast applications, such as those that handle real-time dissemination of financial information, require high performance. Multicast group membership management (IGMP), unicast routing protocols (OSPF, RIP), and multicast routing protocols are all required to enable end-to-end multicast capabilities. The RP is a critical function for PIM-SM deployments. RP redundancy is always recommended. In a shared-tree model, multicast traffic from the multicast source is routed via the RP. If the RP goes down, the multicast receivers do not receive traffic until the RP comes up again. In general, more than one RP is configured (for a group range) to provide RP redundancy. The PIM-SM router acting as a BSR advertises the list of Managing IPv4 and IPv6 Multicast 1159 candidate RPs to all the PIM routers in the network. Each PIM router then runs the RP selection algorithm to determine an RP for the given group range. All the interested PIMSM routers then initiate re-reception of traffic through this new RP, and the multicast traffic is rerouted via the new RP. This is to provide high availability to the multicast applications and help ensure that the multicast traffic is recovered quickly in such scenarios. PIM-SM Protocol Operation This section describes the workings of PIM-SM protocol per RFC 4601. The protocol operates essentially in three phases, as explained in the following sections. Phase-1: RP Tree Figure 42-1. PIM-SM Shared Tree Join • In this example, an active receiver (attached to leaf router at the bottom of the drawing) has joined multicast group “G”. • The leaf router (labeled DR above) knows the IP address of the Rendezvous Point (RP) for group G and sends a (*, G) Join for this group towards the RP. 1160 Managing IPv4 and IPv6 Multicast • This (*, G) Join travels hop-by-hop to the RP, building a branch of the Shared Tree that extends from the RP to the last-hop router directly connected to the receiver. • At this point, group “G” traffic can flow down the Shared Tree to the receiver. Phase-2: Register Stop Figure 42-2. PIM-SM Sender Registration—Part1 • As soon as an active source for group G sends a packet, the designated router (DR) that is attached to this source is responsible for “Registering” this source with the RP and requesting the RP to build a tree back to that router. • To do this, the source router encapsulates the multicast data from the source in a special PIM-SM message, called the Register message, and unicasts that data to the RP. • When the RP receives the Register message, it does two things: – It de-encapsulates the multicast data packet inside of the Register message and forwards it down the Shared Tree. Managing IPv4 and IPv6 Multicast 1161 – The RP sends a source group (S, G) Join back towards the source to create a branch of an (S, G) Shortest-Path Tree (SPT). This results in the (S, G) state being created in the entire router path along the SPT, including the RP. Figure 42-3. PIM-SM Sender Registration—Part 2 • As soon as the SPT is built from the Source router to the RP, multicast traffic begins to flow unencapsulated from source S to the RP. • Once this is complete, the RP Router will send a “Register Stop” message to the first-hop router to tell it to stop sending the encapsulated data to the RP. 1162 Managing IPv4 and IPv6 Multicast Phase 3: Shortest Path Tree Figure 42-4. PIM-SM SPT—Part 1 • PIM-SM has the capability for last-hop routers (i.e., routers with directly connected group members) to switch to the Shortest-Path Tree and bypass the RP. This switchover is based upon an implementation-specific function called SwitchToSptDesired(S,G) in the standard and generally takes a number of seconds to switch to the SPT. • In the above example, the last-hop router (at the bottom of the drawing) sends an (S, G) Join message toward the source to join the SPT and bypass the RP. • This (S, G) Join messages travels hop-by-hop to the first-hop router (i.e., the router connected directly to the source), thereby creating another branch of the SPT. This also creates (S, G) state in all the routers along this branch of the SPT. Managing IPv4 and IPv6 Multicast 1163 Figure 42-5. PIM-SM SPT—Part 2 • Finally, special (S, G) RP-bit Prune messages are sent up the Shared Tree to prune off this (S, G) traffic from the Shared Tree. If this were not done, (S, G) traffic would continue flowing down the Shared Tree resulting in duplicate (S, G) packets arriving at the receiver. 1164 Managing IPv4 and IPv6 Multicast Figure 42-6. PIM-SM SPT—Part 3 • At this point, (S, G) traffic is now flowing directly from the first -hop router to the last-hop router and from there to the receiver. Figure 42-7. PIM-SM SPT—Part 4 Managing IPv4 and IPv6 Multicast 1165 • At this point, the RP no longer needs the flow of (S, G) traffic since all branches of the Shared Tree (in this case there is only one) have pruned off the flow of (S, G) traffic. • As a result, the RP will send (S, G) Prunes back toward the source to shut off the flow of the now unnecessary (S, G) traffic to the RP. NOTE: This will occur if the RP has received an (S, G) RP-bit Prune on all interfaces on the Shared Tree. Figure 42-8. PIM-SM SPT—Part 5 • As a result of the SPT-Switchover, (S, G) traffic is now flowing only from the first-hop router to the last-hop router and from there to the receiver. Notice that traffic is no longer flowing to the RP. The PIM standard requires support for multi-hop RP in that a router running PIM can act as an RP even if it is multiple router hops away from the multicast source. This requires that the first-hop router perform encapsulation of the multicast data and forward it as unicast toward the RP. In practice, this encapsulation is almost always performed in software due to the complexity of the operation. Likewise, the RP must perform deencapsulation and forwarding of the multicast packets in software. This 1166 Managing IPv4 and IPv6 Multicast creates a performance problem in that it limits the number of packets that can be processed and places a high load on the CPUs in the first hop and RP routers, which can then adversely affect other router functions. PowerConnect Optimizations to PIM-SM PowerConnect Switches performs the following optimizations to reduce the impact of multicast encapsulation/de-encapsulation and provide a higher level of multicast performance in the network. • Limiting the number of packets sent to the RP by the first-hop router. When a multicast data source (S) starts sending data destined for a multicast group (G), the first-hop router receives these packets and traps them to its local CPU. A PowerConnect first-hop router immediately blocks further data packets in the stream and prevents them from reaching the CPU. The first-hop router then unicast-encapsulates the first received data packet in the form of a PIM Register message and software forwards it to the RP. When a PowerConnect first-hop router subsequently receives the PIM Join from the RP, the block is replaced with a regular multicast forwarding entry so that subsequent data packets are forwarded in the hardware. If the initial Register message(s) does not reach the RP, or the PIM Join sent in response does not reach the first-hop router, then the data stream would never get forwarded. To solve this, the negative entry is timed out and removed after 3 seconds so that the process can be repeated until it succeeds. • In Phase 3—Shortest Path Tree, the last-hop router initiates a switchover to the SPT tree by sending a PIM (S,G) Join message towards the source as soon as it receives the first data packet via the (*,G) shared tree. Per the standard, this function is used to detect suboptimal routing of multicast traffic. PowerConnect multicast eliminates the SwitchToSptDesired(S,G) function and performs as if the SwitchToSptDesired(S,G) function always returns “true” as soon as it receives the first multicast packet instead of waiting for 30 seconds. • PowerConnect RPs do not wait to receive the native multicast data but immediately respond to the PIM (S,G) Join by sending a 'Register Stop' message to the source's first-hop router to inform it that it can stop Managing IPv4 and IPv6 Multicast 1167 sending the encapsulated Register messages. This removes the load from the CPU of the first-hop router and the RP, as they no longer need to encapsulate and de-encapsulate register messages with multicast data. These optimizations significantly reduce the load on first-hop routers and RPs to encapsulate/de-encapsulate PIM register messages and their associated multicast data. In addition, the switchover to the SPT is initiated immediately upon the first multicast packet reaching the last-hop router. This leads to significantly faster response times for receiving the full multicast stream directly from the first-hop router (as opposed to the typical bandwidth-limited stream traversing the RP). Using PIM-DM as the Multicast Routing Protocol Unlike PIM-SM, PIM-DM creates source-based shortest-path distribution trees that make use of reverse-path forwarding (RPF). PIM-DM assumes that when a sender starts sending data, all downstream routers and hosts want to receive a multicast datagram. PIM-DM initially floods multicast traffic throughout the network. Routers that do not have any downstream neighbors prune back the unwanted traffic. In addition to PRUNE messages, PIM-DM makes use of graft and assert messages. Graft messages are used whenever a new host wants to join the group. Assert messages are used to shutoff duplicate flows on the same multi-access network. There are two versions of PIM-DM. Version 2 does not use the IGMP message; instead, it uses a message that is encapsulated in an IP package, with protocol number 103. In Version 2, a Hello message is introduced in place of a query message. PIM-DM is appropriate for: • Densely distributed receivers • Few senders-to-many receivers (due to frequent flooding) • High volume of multicast traffic • Constant stream of traffic To minimize the repeated flooding of datagrams and subsequent pruning associated with a particular source-group (S,G) pair, PIM-DM uses a State Refresh message. This message is sent by the router(s) directly connected to the source and is propagated throughout the network. When received by a 1168 Managing IPv4 and IPv6 Multicast router on its RPF interface, the State Refresh message causes an existing prune state to be refreshed. State Refresh messages are generated periodically by the router directly attached to the source. What Is DVMRP? DVMRP is an interior gateway protocol that is suitable for routing multicast traffic within an autonomous system (AS). DVMRP should not be used between different autonomous systems due to limitations with hop count and scalability. NOTE: In addition to DVMRP, the switch supports the Protocol-Independent Multicast (PIM) sparse-mode (PIM-SM) and dense-mode (PIM-SM) routing protocol. Only one multicast routing protocol can be operational on the switch at any time. If you enable DVMRP, PIM must be disabled. Similarly, if PIM is enabled, DVMRP must be disabled. DVMRP exchanges probe packets with all its DVMRP-enabled routers, it establishes two-way neighboring relationships, and it builds a neighbor table. DVMRP exchanges report packets and creates a unicast topology table, with which it builds the multicast routing table. This table is used to route the multicast packets. Since every DVMRP router uses the same unicast routing protocol, routing loops are avoided. Understanding DVMRP Multicast Packet Routing DVMRP is based on RIP; it forwards multicast datagrams to other routers in the AS and constructs a forwarding table based on information it learns in response. More specifically, it uses this sequence. • A new multicast packet is forwarded to the entire multicast network, with respect to the time-to-live (TTL) of the packet. • The TTL restricts the area to be flooded by the message. • All routers that do not have members on directly-attached subnetworks send back Prune messages to the upstream router. • The branches that transmit a prune message are deleted from the delivery tree. • The delivery tree which is spanning to all the members in the multicast group, is constructed in the form of a DVMRP forwarding table. Managing IPv4 and IPv6 Multicast 1169 Using DVMRP as the Multicast Routing Protocol DVMRP is used to communicate multicast information between L3 switches or routers. If a PowerConnect 7000 Series switch handles inter-VLAN routing for IP traffic, including IP multicast traffic, multicast routing might be required on the switch. DVMRP is best suited for small networks where the majority of hosts request a given multicast traffic stream. DVMRP is similar to PIM-DM in that it floods multicast packets throughout the network and prunes branches where the multicast traffic is not desired. DVMRP was developed before PIM-DM, and it has several limitations that do not exist with PIM-DM. You might use DVMRP as the multicast routing protocol if it has already been widely deployed within the network. Microsoft Network Load Balancing PowerConnect switches support Microsoft Network Load Balancing (NLB) in unicast mode only. When using Microsoft NLB, ensure that the Cluster Operation Mode is configured to the default value of Unicast. 1170 Managing IPv4 and IPv6 Multicast Default L3 Multicast Values IP and IPv6 multicast is disabled by default. Table 42-2 shows the default values for L3 multicast and the multicast protocols. Table 42-2. L3 Multicast Defaults Parameter Default Value IPv4 Multicast Defaults L3 Multicast Admin Mode Disabled Maximum Multicast Routing Table Entries 2048 (1536 IPv4/512 IPv6) Sizes for the PC70xx switches are as follows: 1536 IPv4/512 IPv6 Static Multicast Routes None configured Interface TTL Threshold 1 IGMP Defaults IGMP Admin Mode Disabled globally and on all interfaces IGMP Version v3 IGMP Robustness 2 IGMP Query Interval 125 seconds IGMP Query Max Response Time 100 seconds IGMP Startup Query Interval 31 seconds IGMP Startup Query Count 2 IGMP Last Member Query Interval 1 second IGMP Last Member Query Count 2 IGMP Proxy Interface Mode Disabled IGMP Proxy Unsolicited Report Interval 1 second MLD Defaults MLD Admin Mode Disabled globally and on all interfaces MLD Version v2 MLD Query Interval 125 seconds Managing IPv4 and IPv6 Multicast 1171 Table 42-2. L3 Multicast Defaults (Continued) Parameter Default Value MLD Query Max Response Time 10,000 milliseconds MLD Last Member Query Interval 1000 milliseconds MLD Last Member Query Count 2 MLD Proxy Interface Mode Disabled MLD Proxy Unsolicited Report Interval 1 second PIM Defaults PIM Protocol Disabled globally and on all interfaces PIM Hello Interval 30 seconds (when enabled on an interface) PIM-SM Join/Prune Interval 60 seconds (when enabled on an interface) PIM-SM BSR Border Disabled PIM-SM DR Priority 1 (when enabled on an interface) PIM Candidate Rendezvous Points (RPs) None configured PIM Static RP None configured PIM Source-Specific Multicast (SSM) Range None configured. Default SSM group address is 232.0.0.0/8 for IPv4 multicast and ff3x::/32 for IPv6 multicast. PIM BSR Candidate Hash Mask Length 30 (IPv4) 126 (IPv6) PIM BSR Candidate Priority 0 DVMRP Defaults DVMRP Admin Mode Disabled globally and on all interfaces DVMRP Version 3 DVMRP Interface Metric 1 1172 Managing IPv4 and IPv6 Multicast Configuring General IPv4 Multicast Features (Web) This section provides information about the OpenManage Switch Administrator pages for configuring and monitoring the L3 multicast features that are not protocol-specific on a PowerConnect 7000 Series switch. For details about the fields on a page, click at the top of the page. Multicast Global Configuration Use the Global Configuration page to configure the administrative status of Multicast Forwarding in the router, and to display global multicast parameters. To display the page, click IPv4 Multicast → Multicast → Global Configuration in the navigation panel. Figure 42-9. Multicast Global Configuration Managing IPv4 and IPv6 Multicast 1173 Multicast Interface Configuration Use the Interface Configuration page to configure the TTL threshold of a multicast interface. At least one VLAN routing interface must be configured on the switch before fields display on this page. To display the page, click IPv4 Multicast → Multicast → Interface Configuration in the navigation panel. Figure 42-10. 1174 Multicast Interface Configuration Managing IPv4 and IPv6 Multicast Multicast Route Table Use the Route Table page to view information about the multicast routes in the IPv4 multicast routing table. To display the page, click IPv4 Multicast → Multicast → Multicast Route Table Multicast Route Table Figure 42-11. Multicast Route Table Managing IPv4 and IPv6 Multicast 1175 Multicast Admin Boundary Configuration The definition of an administratively scoped boundary is a way to stop the ingress and egress of multicast traffic for a given range of multicast addresses on a given routing interface. Use the Admin Boundary Configuration page to configure a new or existing administratively scoped boundary. To see this page, you must have configured a valid routing interface and multicast. To display the page, click IPv4 Multicast → Multicast → Admin Boundary Configuration in the navigation panel. Figure 42-12. 1176 Multicast Admin Boundary Configuration Managing IPv4 and IPv6 Multicast Multicast Admin Boundary Summary Use the Admin Boundary Summary page to display existing administratively scoped boundaries. To display the page, click IPv4 Multicast → Multicast → Admin Boundary Summary in the navigation panel. Figure 42-13. Multicast Admin Boundary Summary Managing IPv4 and IPv6 Multicast 1177 Multicast Static MRoute Configuration Use the Static MRoute Configuration page to configure a new static entry in the Mroute table or to modify an existing entry. To display the page, click IPv4 Multicast → Multicast → Static MRoute Configuration in the navigation panel. Figure 42-14. 1178 Multicast Static MRoute Configuration Managing IPv4 and IPv6 Multicast Multicast Static MRoute Summary Use the Static MRoute Summary page to display static routes and their configurations. To display the page, click IPv4 Multicast → Multicast → Static MRoute Summary in the navigation panel. Figure 42-15. Multicast Static MRoute Summary Managing IPv4 and IPv6 Multicast 1179 Configuring IPv6 Multicast Features (Web) This section provides information about the OpenManage Switch Administrator pages for configuring and monitoring the IPv6 multicast features that are not protocol-specific on a PowerConnect 7000 Series switch. For details about the fields on a page, click at the top of the page. IPv6 Multicast Route Table Use the Multicast Route Table page to view information about the multicast routes in the IPv6 multicast routing table. To display the page, click IPv6 Multicast → Multicast → Multicast Route Table. Figure 42-16. 1180 IPv6 Multicast Route Table Managing IPv4 and IPv6 Multicast Configuring IGMP and IGMP Proxy (Web) This section provides information about the OpenManage Switch Administrator pages for configuring and monitoring the IGMP and IGMP proxy features on a PowerConnect 7000 Series switch. For details about the fields on a page, click at the top of the page. IGMP Global Configuration Use the Global Configuration page to set IGMP on the system to active or inactive. To display the page, click IPv4 Multicast → IGMP → Global Configuration in the navigation panel. Figure 42-17. IGMP Global Configuration Managing IPv4 and IPv6 Multicast 1181 IGMP Interface Configuration Use the Interface Configuration page to configure and/or display router interface parameters. You must configure at least one valid routing interface before you can access this page and configure IP Multicast IGMP. To display the page, click IPv4 Multicast → IGMP → Routing Interface → Interface Configuration in the navigation panel. Figure 42-18. 1182 IGMP Interface Configuration Managing IPv4 and IPv6 Multicast IGMP Interface Summary Use the Interface Summary page to display IGMP routing parameters and data. You must configure at least one IGMP router interface to access this page. To display the page, click IPv4 Multicast → IGMP → Routing Interface → Interface Summary in the navigation panel. Figure 42-19. IGMP Interface Summary Managing IPv4 and IPv6 Multicast 1183 IGMP Cache Information Use the Cache Information page to display cache parameters and data for an IP multicast group address. Group membership reports must have been received on the selected interface for data to display on the page. To display the page, click IPv4 Multicast → IGMP → Routing Interface → Cache Information in the navigation panel. Figure 42-20. 1184 IGMP Cache Information Managing IPv4 and IPv6 Multicast IGMP Interface Source List Information Use the Source List Information page to display detailed membership information for an interface. Group membership reports must have been received on the selected interface for data to display information. To display the page, click IPv4 Multicast → IGMP → Routing Interface → Source List Information in the navigation panel. Figure 42-21. IGMP Interface Source List Information Managing IPv4 and IPv6 Multicast 1185 IGMP Proxy Interface Configuration The IGMP Proxy is used by IGMP Router (IPv4 system) to enable the system to issue IGMP host messages on behalf of hosts that the system discovered through standard IGMP router interfaces. Thus, this feature acts as proxy to all hosts residing on its router interfaces. Use the Interface Configuration page to configure IGMP proxy for a VLAN interface. You must have configured at least one VLAN routing interface before configuring or displaying data for an IGMP proxy interface, and it should not be an IGMP routing interface. To display the page, click IPv4 Multicast → IGMP → Proxy Interface → Interface Configuration in the navigation panel. Figure 42-22. 1186 IGMP Proxy Interface Configuration Managing IPv4 and IPv6 Multicast IGMP Proxy Configuration Summary Use the Configuration Summary page to display proxy interface configurations by interface. You must have configured at least one VLAN routing interface configured before data displays on this page. To display the page, click IPv4 Multicast → IGMP → Proxy Interface → Configuration Summary in the navigation panel. Figure 42-23. IGMP Proxy Configuration Summary Managing IPv4 and IPv6 Multicast 1187 IGMP Proxy Interface Membership Info Use the Interface Membership Info page to display interface membership data for a specific IP multicast group address. You must have configured at least one VLAN routing interface before you can display interface membership information, and it should not be an IGMP routing interface. Also, if no group membership reports have been received on the selected interface, no data displays on this page. To display the page, click IPv4 Multicast → IGMP → Proxy Interface → Interface Membership Info in the navigation panel. Figure 42-24. 1188 IGMP Proxy Interface Membership Info Managing IPv4 and IPv6 Multicast Detailed IGMP Proxy Interface Membership Information Use the Interface Membership Info Detailed page to display detailed interface membership data. You must have configured at least one VLAN routing interface before you can display detailed interface membership information, and it should not be an IGMP routing interface. Also, if no group membership reports have been received on the selected interface you cannot display data. To display the page, click IPv4 Multicast → IGMP → Proxy Interface → Interface Membership Info Detailed in the navigation panel. Figure 42-25. IGMP Proxy Interface Membership Info Detailed Managing IPv4 and IPv6 Multicast 1189 Configuring MLD and MLD Proxy (Web) This section provides information about the OpenManage Switch Administrator pages for configuring and monitoring the MLD and MLD proxy features on a PowerConnect 7000 Series switch. For details about the fields on a page, click at the top of the page. MLD Global Configuration Use the Global Configuration page to administratively enable and disable the MLD service. To display the page, click IPv6 Multicast → MLD → Global Configuration in the navigation panel. Figure 42-26. 1190 MLD Global Configuration Managing IPv4 and IPv6 Multicast MLD Routing Interface Configuration Use the Interface Configuration page to enable selected IPv6 router interfaces to discover the presence of multicast listeners, the nodes who wish to receive the multicast data packets, on its directly attached interfaces. To access this page, click IPv6 Multicast → MLD → Routing Interface → Interface Configuration in the navigation panel. Figure 42-27. MLD Routing Interface Configuration Managing IPv4 and IPv6 Multicast 1191 MLD Routing Interface Summary Use the Interface Summary page to display information and statistics on a selected MLD-enabled interface. You must configure at least one IGMP VLAN routing interface to access this page. To access this page, click IPv6 Multicast → MLD → Routing Interface → Interface Summary in the navigation panel. Figure 42-28. 1192 MLD Routing Interface Summary Managing IPv4 and IPv6 Multicast MLD Routing Interface Cache Information The Interface Cache Information page displays cache parameters and data for an IP multicast group address that has been reported to operational MLD routing interfaces. You must configure at least one MLD VLAN routing interface to access this page. Also, group membership reports must have been received on the selected interface in order for data to be displayed here. To access this page, click IPv6 Multicast → MLD → Routing Interface → Cache Information in the navigation panel. Figure 42-29. MLD Routing Interface Cache Information Managing IPv4 and IPv6 Multicast 1193 MLD Routing Interface Source List Information The Interface Source List Information page displays detailed membership information for an interface. You must configure at least one MLD VLAN routing interface to access this page. Also, group membership reports must have been received on the selected interface in order for data to be displayed here. To access this page, click IPv6 Multicast → MLD → Routing Interface → Source List Information in the navigation panel. Figure 42-30. 1194 MLD Routing Interface Source List Information Managing IPv4 and IPv6 Multicast MLD Traffic The MLD Traffic page displays summary statistics on the MLD messages sent to and from the router. To access this page, click IPv6 Multicast → MLD → Routing Interface → MLD Traffic in the navigation panel. Figure 42-31. MLD Traffic Managing IPv4 and IPv6 Multicast 1195 MLD Proxy Configuration When you configure an interface in MLD proxy mode, it acts as a proxy multicast host that sends MLD membership reports on one VLAN interface for MLD Membership reports received on all other MLD-enabled VLAN routing interfaces. Use the Interface Configuration page to enable and disable ports as MLD proxy interfaces. To display this page, click IPv6 Multicast → MLD → Proxy Interface → Interface Configuration in the navigation panel. Figure 42-32. 1196 MLD Proxy Interface Configuration Managing IPv4 and IPv6 Multicast MLD Proxy Configuration Summary Use the Configuration Summary page to view configuration and statistics on MLD proxy-enabled interfaces. To display this page, click IPv6 Multicast → MLD → Proxy Interface → Configuration Summary in the navigation panel. Figure 42-33. MLD Proxy Configuration Summary Managing IPv4 and IPv6 Multicast 1197 MLD Proxy Interface Membership Information The Interface Membership Information page lists each IP multicast group for which the MLD proxy interface has received membership reports. To display this page, click IPv6 Multicast → MLD → Proxy interface → Interface Membership Info in the navigation panel. Figure 42-34. 1198 Interface Membership Information Managing IPv4 and IPv6 Multicast Detailed MLD Proxy Interface Membership Information The Interface Membership Information Detailed page provides additional information about the IP multicast groups for which the MLD proxy interface has received membership reports. To display this page, click IPv6 Multicast → MLD → Proxy Interface → Interface Membership Info Detailed in the navigation panel. Figure 42-35. Interface Membership Information—Detailed Managing IPv4 and IPv6 Multicast 1199 Configuring PIM for IPv4 and IPv6 (Web) This section provides information about the OpenManage Switch Administrator pages for configuring and monitoring PIM-SM and PIM-DM for IPv4 and IPv6 multicast routing on a PowerConnect 7000 Series switch. For details about the fields on a page, click at the top of the page. NOTE: The OpenManage Switch Administrator pages to configure IPv4 multicast routing and IPv6 multicast routing is very similar. The figures in this section show the IPv4 multicast configuration pages. To configure IPv6 multicast with PIM, use the pages available from the IPv6 Multicast → PIM menu. PIM Global Configuration Use the Global Configuration page to configure the administrative status of PIM-DM or PIM-SM on the switch. It is strongly recommended that IGMP be enabled on any switch on which IPv4 PIM is enabled and MLD be enabled on any switch for which IPv6 PIM is enabled. This ensures that the multicast router behaves as expected. To display the page, click IPv4 Multicast → PIM → Global Configuration or IPv6 Multicast → PIM → Global Configuration in the navigation panel. Figure 42-36. 1200 PIM-DM Global Configuration Managing IPv4 and IPv6 Multicast PIM Global Status Use the Global Status page to view the administrative status of PIM-DM or PIM-SM on the switch. To display the page, click IPv4 Multicast → PIM → Global Status or IPv6 Multicast → PIM → Global Status in the navigation panel. Figure 42-37. PIM Global Status Managing IPv4 and IPv6 Multicast 1201 PIM Interface Configuration Use the Interface Configuration page to configure specific VLAN routing interfaces with PIM. To display the page, click IPv4 Multicast → PIM → Interface Configuration or IPv6 Multicast → PIM → Interface Configuration in the navigation panel. Figure 42-38. 1202 PIM Interface Configuration Managing IPv4 and IPv6 Multicast PIM Interface Summary Use the Interface Summary page to display a PIM-enabled VLAN routing interface interface and its settings. To display the page, click IPv4 Multicast → PIM → Interface Summary or IPv6 Multicast → PIM → Interface Summary in the navigation panel. Figure 42-39. PIM Interface Summary Managing IPv4 and IPv6 Multicast 1203 Candidate RP Configuration The Candidate RP is configured on the Add Candidate RP page. Use the Candidate RP Configuration page to display and delete the configured rendezvous points (RPs) for each port using PIM. To access the page, click IPv4 Multicast → PIM → Candidate RP Configuration or IPv6 Multicast → PIM → Candidate RP Configuration. Figure 42-40. Candidate RP Configuration Adding a Candidate RP To add PIM Candidate rendezvous points (RPs) for each IP multicast group: 1 Open the Candidate RP Configuration page. 2 Click Add. The Add Candidate RP page displays. 1204 Managing IPv4 and IPv6 Multicast Figure 42-41. Add Candidate RP 3 Select the VLAN interface for which the Candidate RP is to be configured. 4 Enter the group address transmitted in Candidate-RP-Advertisements. 5 Enter the prefix length transmitted in Candidate-RP-Advertisements to fully identify the scope of the group which the router supports if elected as a Rendezvous Point. 6 Click Apply Changes. The new Candidate RP is added, and the device is updated. Managing IPv4 and IPv6 Multicast 1205 Static RP Configuration Use the Static RP Configuration page to display or remove the configured RP. The page also allows adding new static RPs by clicking the Add button. Only one RP address can be used at a time within a PIM domain. If the PIM domain uses the BSR to dynamically learn the RP, configuring a static RP is not required. However, you can configure the static RP to override any dynamically learned RP from the BSR. To access the page, click IPv4 Multicast → PIM → Static RP Configuration or IPv6 Multicast → PIM → Static RP Configuration. Figure 42-42. Static RP Configuration Adding a Static RP To add a static RP for the PIM router. 1 Open the Static RP Configuration page. 2 Click Add. The Add Static RP page displays. 1206 Managing IPv4 and IPv6 Multicast Figure 42-43. Add Static RP 3 Enter the IP address of the RP for the group range. 4 Enter the group address of the RP. 5 Enter the group mask of the RP. 6 Check the Override option to configure the static RP to override the dynamic (candidate) RPs learned for same group ranges. 7 Click Apply. The new Static RP is added, and the device is updated. Managing IPv4 and IPv6 Multicast 1207 SSM Range Configuration Use this page to display or remove the Source Specific Multicast (SSM) group IP address and group mask for the PIM router. To display the page, click IPv4 Multicast → PIM → SSM Range Configuration or IPv6 Multicast → PIM → SSM Range Configuration. Figure 42-44. SSM Range Configuration Adding an SSM Range To add the Source-Specific Multicast (SSM) Group IP Address and Group Mask (IPv4) or Prefix Length (IPv6) for the PIM router: 1 Open the SSM Range Configuration page. 2 Click Add. The Add SSM Range page displays. 1208 Managing IPv4 and IPv6 Multicast Figure 42-45. Add SSM Range 3 Click the Add Default SSM Range check box to add the default SSM Range. The default SSM Range is 232.0.0.0/8 for IPv4 multicast and ff3x::/32 for IPv6 multicast. 4 Enter the SSM Group IP Address. 5 Enter the SSM Group Mask (IPv4) or SSM Prefix Length (IPv6). 6 Click Apply. The new SSM Range is added, and the device is updated. Managing IPv4 and IPv6 Multicast 1209 BSR Candidate Configuration Use this page to configure information to be used if the interface is selected as a bootstrap router. To display the page, click IPv4 Multicast → PIM → BSR Candidate Configuration or IPv6 Multicast → PIM → BSR Candidate Configuration. Figure 42-46. 1210 BSR Candidate Configuration Managing IPv4 and IPv6 Multicast BSR Candidate Summary Use this page to display information about the configured BSR candidates. To display this page, click IPv4 Multicast → PIM → BSR Candidate Summary or IPv6 Multicast → PIM → BSR Candidate Summary. Figure 42-47. BSR Candidate Summary Managing IPv4 and IPv6 Multicast 1211 Configuring DVMRP (Web) This section provides information about the OpenManage Switch Administrator pages for configuring and monitoring DVMRP on a PowerConnect 7000 Series switch. For details about the fields on a page, click at the top of the page. DVMRP Global Configuration Use the Global Configuration page to configure global DVMRP settings. It is strongly recommended that IGMP be enabled on any switch on which DVMRP is enabled. The use cases for enabling DVMRP without IGMP are few, and enabling IGMP ensures that the multicast router behaves as expected. To display the page, click IPv4 Multicast → DVMRP → Global Configuration in the navigation panel. Figure 42-48. 1212 DVMRP Global Configuration Managing IPv4 and IPv6 Multicast DVMRP Interface Configuration Use the Interface Configuration page to configure a DVMRP VLAN routing interface. You must configure at least one router interface before you configure a DVMRP interface. Otherwise you see a message telling you that no router interfaces are available, and the configuration screen is not displayed. It is strongly recommended that IGMP be enabled on any interface on which DVMRP is enabled. This ensures that the multicast router behaves as expected. To display the page, click IPv4 Multicast → DVMRP → Interface Configuration in the navigation panel. Figure 42-49. DVMRP Interface Configuration Managing IPv4 and IPv6 Multicast 1213 DVMRP Configuration Summary Use the Configuration Summary page to display the DVMRP configuration and data for a selected interface. You must configure at least one VLAN routing interface before you can display data for a DVMRP interface. Otherwise you see a message telling you that no VLAN router interfaces are available, and the configuration summary screen is not displayed. To display the page, click IPv4 Multicast → DVMRP → Configuration Summary in the navigation panel. 1214 Managing IPv4 and IPv6 Multicast Figure 42-50. DVMRP Configuration Summary DVMRP Next Hop Summary Use the Next Hop Summary page to display the next hop summary by Source IP. To display the page, click IPv4 Multicast → DVMRP → Next Hop Summary in the navigation panel. Managing IPv4 and IPv6 Multicast 1215 Figure 42-51. 1216 DVMRP Next Hop Summary Managing IPv4 and IPv6 Multicast DVMRP Prune Summary Use the Prune Summary page to display the prune summary by Group IP. To display the page, click IPv4 Multicast → DVMRP → Prune Summary in the navigation panel. Figure 42-52. DVMRP Prune Summary Managing IPv4 and IPv6 Multicast 1217 DVMRP Route Summary Use the Route Summary page to display the DVMRP route summary. To display the page, click IPv4 Multicast → DVMRP → Route Summary in the navigation panel. Figure 42-53. 1218 DVMRP Route Summary Managing IPv4 and IPv6 Multicast Configuring L3 Multicast Features (CLI) This section provides information about the commands you use to configure general IPv4 multicast settings on the switch. For more information about the commands, see the PowerConnect 7000 Series CLI Reference Guide at support.dell.com/manuals. Configuring and Viewing IPv4 Multicast Information Beginning in Privileged EXEC mode, use the following commands to enable IPv4 multicast on the switch and to view and configure other general multicast settings. Command Purpose configure Enter global configuration mode. ip multicast Enable IPv4/IPv6 multicast on the switch. ip mroute source-address Create a static multicast route for a source range. mask rpf-address preference • source-address — The IP address of the multicast data source. • mask — The IP subnet mask of the multicast data source. • rpf-address — The IP address of the next hop towards the source. • preference — The cost of the route (Range: 1–255). interface vlan vlan-id Enter Interface Configuration mode for the specified VLAN. ip mcast boundary Add an administrative scope multicast boundary specified by the multicast group IP address (groupipaddr) and group IP subnet mask (mask) for which this multicast administrative boundary is applicable. groupipaddr mask The group IP address valid range is 239.0.0.0 to 239.255.255.255. ip multicast ttl-threshold ttlvalue Apply a Time to Live (TTL) value to the interface. The ttlvalue is the TTL threshold which is applied to the multicast data packets forwarded through the interface. Managing IPv4 and IPv6 Multicast 1219 Command Purpose exit Exit to Global Config mode. exit Exit to Privileged EXEC mode. show ip multicast View system-wide multicast information. show ip mcast boundary {vlan vlan-id | all} View all the configured administrative scoped multicast boundaries. show ip mcast mroute {detail | summary} View a summary or all the details of the multicast table. show mac address-table multicast [count] View information about the entries in the multicast address table. show ip mcast mroute View the multicast configuration settings such as flags, group groupipaddr {detail | timer settings, incoming and outgoing interfaces, RPF summary} neighboring routers, and expiration times of all the entries in the multicast mroute table containing the groupipaddr value. show ip mcast mroute source sourceipaddr {summary | groupipaddr} View the multicast configuration settings such as flags, timer settings, incoming and outgoing interfaces, RPF neighboring routers, and expiration times of all the entries in the multicast mroute table containing the sourceipaddr or sourceipaddr | groupipaddr pair value(s). show ip mcast mroute static View all the static routes configured in the static mcast [sourceipaddr ] table if it is specified or display the static route associated with the particular sourceipaddr. 1220 Managing IPv4 and IPv6 Multicast Configuring and Viewing IPv6 Multicast Route Information Beginning in Privileged EXEC mode, use the following commands to configure static IPv6 multicast routes on the switch and to view IPv6 multicast table information. Command Purpose configure Enter global configuration mode. ip multicast Enable IPv4/IPv6 multicast routing. ipv6 mroute source- Create a static multicast route for a source range. address/prefix-length rpf- • source-address/prefix-length — The IPv6 address of the address [interface vlan multicast data source. vlan-id] preference • rpf-address — The IPv6 address of the next hop towards the source. • vlan-id — If the rpf-address is a link-local address then the VLAN interface must also be specified. If the rpfaddress is a global address, then specifying the VLAN interface is not required. • preference — The cost of the route (Range: 1–255). exit Exit to Privileged EXEC mode. show ipv6 mroute {detail | summary} View a summary or all the details of the multicast table. show ipv6 mroute group View the multicast configuration settings such as flags, groupipaddr {detail | timer settings, incoming and outgoing interfaces, RPF summary} neighboring routers, and expiration times of all the entries in the multicast mroute table containing the groupipaddr value. show ipv6 mroute source View the multicast configuration settings such as flags, sourceipaddr {summary timer settings, incoming and outgoing interfaces, RPF | groupipaddr} neighboring routers, and expiration times of all the entries in the multicast mroute table containing the sourceipaddr or sourceipaddr | groupipaddr pair value(s). show ipv6 mroute static View all the static routes configured in the static mcast [sourceipaddr ] table if it is specified or display the static route associated with the particular sourceipaddr. Managing IPv4 and IPv6 Multicast 1221 Configuring and Viewing IGMP Beginning in Privileged EXEC mode, use the following commands to configure IGMP on the switch and on VLAN routing interfaces and to view IGMP information. Command Purpose configure Enter global configuration mode. ip multicast Enable IPv4/IPv6 multicast routing. ip igmp Enable IGMP on the switch. interface vlan vlan-id Enter Interface Configuration mode for the specified VLAN. ip igmp Enable IGMP on the interface. ip igmp version version Set the version of IGMP for an interface. The version variable can be 1, 2, or 3. ip igmp robustness robustness Configure the robustness that allows tuning of the interface, that is, tuning for the expected packet loss on a subnet. If a subnet is expected to have significant loss, the robustness variable may be increased for the interface. The range for robustness is 1–255. ip igmp query-interval seconds Configure the query interval for the specified interface. The query interval determines how fast IGMP HostQuery packets are transmitted on this interface. The range for seconds is 0–3600 seconds. ip igmp query-maxresponse-time seconds Configure the maximum response time interval for the specified interface. It is the maximum query response time advertised in IGMPv2 queries on this interface. The range for seconds is 0–25 seconds. ip igmp startup-queryinterval seconds Set the interval between general queries sent at startup on the interface. The range for seconds is 0–300 seconds. 1222 Managing IPv4 and IPv6 Multicast Command Purpose ip igmp startup-querycount count Set the number of queries sent out on startup —at intervals equal to the startup query interval for the interface. The range for count is 1–20. ip igmp last-memberquery-interval tenthsofseconds Configure the Maximum Response Time inserted in Group-Specific Queries which are sent in response to Leave Group messages. The range is 0–255 tenths of a second. ip igmp last-memberquery-count count Set the number of Group-Specific Queries sent before the router assumes that there are no local members on the interface. The range for count is 1–20. CTRL + Z Exit to Privileged EXEC mode. show ip igmp View system-wide IGMP information. show ip igmp interface [vlan vlan-id] View IGMP information for all interfaces or for the specified interface. show ip igmp interface stats [vlan vlan-id] View IGMP statistics for all interfaces or for the specified interface. show ip igmp groups [interface vlan vlan-id] View the registered multicast groups on the interface. show ip igmp membership View the list of interfaces that have registered in any multicast group. Managing IPv4 and IPv6 Multicast 1223 Configuring and Viewing IGMP Proxy Beginning in Privileged EXEC mode, use the following commands to configure the upstream VLAN routing interface as an IGMP proxy. The IGMP proxy issues host messages on behalf of the hosts that have been discovered on IGMP-enabled interfaces. The upstream interface is the interface closest to the root multicast router, which should be running IGMP. NOTE: Configure only the upstream interface as the IGMP proxy. IGMP should be enabled on all downstream interfaces. IP routing and IP multicast must be enabled on the switch for the IGMP proxy feature to operate. Command Purpose configure Enter global configuration mode. interface vlan vlan-id Enter Interface Configuration mode for the specified VLAN. ip igmp-proxy Configure the interface as an IGMP proxy interface. ip igmp-proxy reset-status (Optional) Reset the host interface status parameters of the IGMP Proxy. ip igmp-proxy unsolicit-rprtinterval seconds Configure the unsolicited report interval for the IGMP proxy interface. The range for seconds is 0–260 seconds. CTRL + Z Exit to Privileged EXEC mode. show ip igmp-proxy View a summary of the host interface status parameters. show ip igmp-proxy interface View a detailed list of the host interface status parameters. This command displays information only when IGMP Proxy is operational. show ip igmp-proxy groups View a table of information about multicast groups that IGMP Proxy reported. This command displays information only when IGMP Proxy is operational. 1224 Managing IPv4 and IPv6 Multicast Configuring and Viewing MLD Beginning in Privileged EXEC mode, use the following commands to configure MLD on the switch and on VLAN routing interfaces and to view IGMP information. Command Purpose configure Enter global configuration mode. ip multicast Enable IPv4/IPv6 multicast routing. ipv6 mld router Enable MLD on the switch. interface vlan vlan-id Enter Interface Configuration mode for the specified VLAN. ipv6 mld router Enable MLD on the interface. ipv6 mld version version Set the version of MLD for an interface. The version variable can be 1 or 2. ipv6 mld query-interval seconds Configure the query interval for the specified interface. The query interval determines how fast MLD Host-Query packets are transmitted on this interface. The range for seconds is 0–3600 seconds. ipv6 mld query-max-responsetime seconds Configure the maximum response time interval for the specified interface. It is the maximum query response time advertised in MLD queries on this interface. The range for seconds is 0–25 seconds. ipv6 mld last-member-queryinterval tenthsofseconds Set the last member query interval for the MLD interface, which is the value of the maximum response time parameter in the group-specific queries sent out of this interface. The range is 0–65535 milliseconds. ipv6 mld last-member-querycount count Set the number of listener-specific queries sent before the router assumes that there are no local members on the interface. The range for count is 1–20. CTRL + Z Exit to Privileged EXEC mode. Managing IPv4 and IPv6 Multicast 1225 Command Purpose show ipv6 mld interface [vlan vlan-id] View MLD information for all interfaces or for the specified interface. show ipv6 mld interface stats [vlan vlan-id] View MLD statistics for all interfaces or for the specified interface. show ipv6 mld groups [interface vlan vlan-id] View the registered multicast groups on the interface. show ipv6 mld membership View the list of interfaces that have registered in any multicast group. Configuring and Viewing MLD Proxy Beginning in Privileged EXEC mode, use the following commands to configure the upstream VLAN routing interface as an MLD proxy. The MLD proxy issues host messages on behalf of the hosts that have been discovered on the downstream MLD-enabled interfaces. The upstream interface is the interface closest to the root multicast router, which should be running IGMP. NOTE: Configure only the upstream interface as the MLD proxy. MLD should be enabled on all downstream interfaces. IPv6 routing must be enabled on the switch for the MLD proxy feature to operate. Command Purpose configure Enter global configuration mode. interface vlan vlan-id Enter Interface Configuration mode for the specified VLAN. ipv6 mld-proxy Configure the interface as an MLD proxy interface. ipv6 mld-proxy reset-status (Optional) Reset the host interface status parameters of the MLD Proxy. ipv6 igmp-proxy unsolicit-rprtinterval seconds Configure the unsolicited report interval for the MLD proxy interface. The range for seconds is 0–260 seconds. CTRL + Z 1226 Exit to Privileged EXEC mode. Managing IPv4 and IPv6 Multicast Command Purpose show ipv6 mld-proxy View a summary of the host interface status parameters. show ipv6 mld-proxy interface View a detailed list of the host interface status parameters. This command displays information only when MLD Proxy is operational. show ipv6 mld-proxy groups View a table of information about multicast groups that MLD Proxy reported. This command displays information only when MLD Proxy is operational. Configuring and Viewing PIM-DM for IPv4 Multicast Routing Beginning in Privileged EXEC mode, use the following commands to configure PIM-DM for IPv4 multicast routing on the switch and on VLAN routing interfaces and to view PIM-DM information. Command Purpose configure Enter global configuration mode. ip routing Enable ip routing. Routing is required for PIM to calculate where to prune the multicast trees. ip pim dense Enable PIM-DM on the switch. ip igmp Enable IGMP. IGMP is required for PIM to operate properly. ip multicast Enable IPv4/IPv6 multicast routing. interface vlan vlan-id Enter Interface Configuration mode for the specified VLAN. ip pim Enable PIM-DM on the interface. ip igmp Enable IGMP on the interface. IGMP is required for proper operation of PIMDM ip pim hello-interval seconds Specify the number of seconds (range: 0–65535) to wait between sending PIM hello messages on the interface. exit Exit to Privileged EXEC mode. show ip pim View system-wide PIM information. Managing IPv4 and IPv6 Multicast 1227 Command Purpose show ip pim interface vlan vlan-id View the PIM-DM information for the specified interface. show ip pim neighbor [interface vlan vlan-id | all] View a summary or all the details of the multicast table. Configuring and Viewing PIM-DM for IPv6 Multicast Routing Beginning in Privileged EXEC mode, use the following commands to configure PIM-DM for IPv6 multicast routing on the switch and on VLAN routing interfaces and to view PIM-DM information. Command Purpose configure Enter global configuration mode. ip routing Enable IP routing. Routing is required for PIM operation. ipv6 unicast-routing Enable IPv6 routing. IPv6 routing is required for the operation of PIM. ipv6 pim dense Enable PIM-DM on the switch. ip multicast Enable IPv6/IPv6 multicast routing. ip igmp Enable IGMP. IGMP is required for PIM to operate properly. interface vlan vlan-id Enter Interface Configuration mode for the specified VLAN. ipv6 pim Enable PIM on the interface. ipv6 enable Enable IPv6 on the VLAN. ipv6 mld router Enable MLD on the VLAN. MLD is required for PIM. ipv6 pim hello-interval seconds Specify the number of seconds (range: 0–65535) to wait between sending PIM hello messages on the interface. exit Exit to Privileged EXEC mode. show ipv6 pim View system-wide PIM information. 1228 Managing IPv4 and IPv6 Multicast Command Purpose show ipv6 pim interface vlan vlan-id View the PIM information for the specified interface. show ipv6 pim neighbor [interface vlan vlan-id | all] View a summary or all the details of the multicast table. Managing IPv4 and IPv6 Multicast 1229 Configuring and Viewing PIM-SM for IPv4 Multicast Routing Beginning in Privileged EXEC mode, use the following commands to configure PIM-SM for IPv4 multicast routing on the switch and on VLAN routing interfaces and to view PIM-SM information. Command Purpose configure Enter global configuration mode. ip routing Enable ip routing. Routing is required for PIM operation. ip pim sparse Enable PIM-SM as the multicast routing protocol on the switch. ip igmp Enable IGMP. ip multicast Enable IPv4/IPv6 multicast routing. ip pim bsr-candidate vlan Configure the switch to announce its candidacy as a bootstrap router (BSR). vlan-id hash-mask-length [priority] [interval interval] • vlan-id — A valid VLAN ID. • hash-mask-length — The length of a mask that is to be ANDed with the group address before the hash function is called. All groups with the same seed hash correspond to the same RP. For example, if this value is 24, only the first 24 bits of the group addresses matter. This allows you to get one RP for multiple groups. (Range 0–32 bits). • priority — The priority of the candidate BSR. The BSR with the higher priority is preferred. If the priority values are the same, the router with the higher IP address is the BSR. (Range 0–255). • interval — (Optional) Indicates the BSR candidate advertisement interval. The range is from 1 to 16383 seconds. The default value is 60 seconds. 1230 Managing IPv4 and IPv6 Multicast Command Purpose ip pim rp-candidate vlan Configure the router to advertise itself to the BSR vlan-id group-address group- router as a PIM candidate Rendezvous Point (RP) for mask [interval interval] a specific multicast group range. • vlan-id — A valid VLAN ID. • group-address — Group IP address supported by RP. • group-mask — Group subnet mask for group address. • interval — (Optional) Indicates the RP candidate advertisement interval. The range is from 1 to 16383 seconds. The default value is 60 seconds. ip pim rp-address rp-address (Optional) Statically configure the RP address for one group-address group-mask or more multicast groups. Only one RP address can be [override] used at a time within a PIM domain The optional keyword override indicates that if there is a conflict, the RP configured with this command prevails over the RP learned by BSR. ip pim ssm {default | group- Define the Source Specific Multicast (SSM) range of IP multicast addresses. address group-mask } • default — Defines the SSM range access list to 232.0.0.0/8. • group-address group-mask — defines the SSM range. interface vlan vlan-id Enter Interface Configuration mode for the specified VLAN. ip pim hello-interval seconds Specify the number of seconds (range: 0–65535) to wait between sending PIM hello messages on the interface. ip pim bsr-border Prevent bootstrap router (BSR) messages from being sent or received through the interface. ip pim dr-priority priority Set the priority value for which a router is elected as the designated router (DR). The election priority range is 0–2147483647. ip pim join-prune-interval Configure the interface join/prune interval for the PIM-SM router. The interval range is 0–18000 seconds. interval Managing IPv4 and IPv6 Multicast 1231 Command Purpose exit Exit to Global Config mode. exit Exit to Privileged EXEC mode. show ip pim View system-wide PIM information. show ip pim interface vlan View the PIM information for the specified interface. show ip pim neighbor [interface vlan vlan-id | all] View a summary or all the details of the multicast table. show ip pim rp-hash View the RP router being selected for the specified multicast group address from the set of active RP routers. The RP router for the group is selected by using a hash algorithm. show ip pim bsr-router [candidate | elected] View the bootstrap router (BSR) information. show ip pim rp mapping View group-to-RP mappings of which the router is aware (either configured or learned from the BSR) vlan-id groupaddr Configuring and Viewing PIM-SM for IPv6 Multicast Routing Beginning in Privileged EXEC mode, use the following commands to configure PIM-SM for IPv6 multicast routing on the switch and on VLAN routing interfaces and to view PIM-SM information. Command Purpose configure Enter global configuration mode. ip routing Enable IP routing. Routing is required for PIM operation. ipv6 unicast-routing Enable IPv6 routing. IPv6 routing is required for IPv6 PIM. ipv6 pim sparse Enable PIM-SM as the multicast routing protocol on the switch. ip mld router Enable MLD. MLD is required for the proper operation of IPv6 PIM. ip multicast Enable IPv4/IPv6 multicast. 1232 Managing IPv4 and IPv6 Multicast Command Purpose ipv6 pim bsr-candidate vlan Configure the switch to announce its candidacy as a bootstrap router (BSR) vlan-id hash-mask-length [priority] [interval interval] • vlan-id — A valid VLAN ID. • hash-mask-length — The length of a mask that is to be ANDed with the group address before the hash function is called. All groups with the same seed hash correspond to the same RP. For example, if this value is 24, only the first 24 bits of the group addresses matter. This allows you to get one RP for multiple groups. (Range 0–32 bits). • priority — The priority of the candidate BSR. The BSR with the higher priority is preferred. If the priority values are the same, the router with the higher IPv6 address is the BSR. (Range 0–255). • interval — (Optional) Indicates the BSR candidate advertisement interval. The range is from 1 to 16383 seconds. The default value is 60 seconds. ipv6 pim rp-candidate vlan Configure the router to advertise itself to the BSR vlan-id group-address/prefix- router as a PIM candidate Rendezvous Point (RP) for length [interval interval] a specific multicast group range. • vlan-id — A valid VLAN ID. • group-address/prefix-length— Group IPv6 address and prefix length supported by RP. • interval — (Optional) Indicates the RP candidate advertisement interval. The range is from 1 to 16383 seconds. The default value is 60 seconds. ipv6 pim rp-address rp- (Optional) Statically configure the RP address for one address group-address/prefix- or more multicast groups. Only one RP address can be used at a time within a PIM domain length [override] The optional keyword override indicates that if there is a conflict, the RP configured with this command prevails over the RP learned by BSR. Managing IPv4 and IPv6 Multicast 1233 Command Purpose ipv6 pim ssm {default | Define the Source Specific Multicast (SSM) range of group-address/prefix-length } IPv6 multicast addresses. • default — Defines the SSM range access list to FF3x::/32. • group-address/prefix-length — defines the SSM range. interface vlan vlan-id Enter Interface Configuration mode for the specified VLAN. ipv6 pim Enable PIM on the VLAN. ipv6 enable Enable IPv6 on the VLAN. ipv6 mld router Enable MLD on the VLAN. MLD is required for IPv6 PIM. ipv6 pim hello-interval Specify the number of seconds (range: 0–65535) to wait between sending PIM hello messages on the interface. ipv6 pim bsr-border Prevent bootstrap router (BSR) messages from being sent or received through the interface. ipv6 pim dr-priority priority Set the priority value for which a router is elected as the designated router (DR). The election priority range is 0–2147483647. seconds ipv6 pim join-prune-interval Configure the interface join/prune interval for the interval PIM-SM router. The interval range is 0–18000 seconds. exit Exit to Global Config mode. exit Exit to Privileged EXEC mode. show ipv6 pim View system-wide PIM information. show ipv6 pim interface vlan View the PIM information for the specified interface. vlan-id show ipv6 pim neighbor [interface vlan vlan-id | all] 1234 View a summary or all the details of the multicast table. Managing IPv4 and IPv6 Multicast Command Purpose show ipv6 pim rp-hash View the RP router being selected for the specified multicast group address from the set of active RP routers. The RP router for the group is selected by using a hash algorithm. show ipv6 pim bsr-router View the bootstrap router (BSR) information. show ipv6 pim rp mapping View group-to-RP mappings of which the router is aware (either configured or learned from the BSR) groupaddr Managing IPv4 and IPv6 Multicast 1235 Configuring and Viewing DVMRP Information Beginning in Privileged EXEC mode, use the following commands to configure DVMRP on the switch and on VLAN routing interfaces and to view DVMRP information. Command Purpose configure Enter global configuration mode. ip dvmrp Enable DVMRP on the switch. ip multicast Enable IP multicast. interface vlan vlan-id Enter Interface Configuration mode for the specified VLAN routing interface. ip dvmrp Enable DVMRP on the interface. ip dvmrp metric metric Configure the metric (range: 1–31) for an interface. This value is used in the DVMRP messages as the cost to reach this network. exit Exit to Privileged EXEC mode. show ip dvmrp interface View the multicast information for the specified interface. vlan vlan-id] show ip dvmrp neighbor View neighbor information for DVMRP. show ip dvmrp nexthop View the next hop information on outgoing interfaces for routing multicast datagrams. show ip dvmrp prune View the table that lists the router’s upstream prune information show ip dvmrp route View the multicast routing information for DVMRP. 1236 Managing IPv4 and IPv6 Multicast L3 Multicast Configuration Examples This section contains the following configuration examples: • Configuring Multicast VLAN Routing With IGMP and PIM-SM • Configuring DVMRP Configuring Multicast VLAN Routing With IGMP and PIM-SM This example describes how to configure a PowerConnect switch with two VLAN routing interfaces that route IP multicast traffic between the VLANs. PIM and IGMP are enabled on the switch and interfaces to manage the multicast routing. VLAN 10 is statically configured as the RP for the multicast group. NOTE: PIM does not require OSPF specifically; static routing or RIP could also be configured for unicast routing. The configuration in this example takes place on L3 switch A shown in Figure 42-54. The red arrows indicate the path that multicast traffic takes. L3 Switch A is configured as the RP for the PIM domain, so it is in charge of sending the multicast stream to L3 Switch B and L3 Switch C, and these switches forward the multicast data to the hosts that have requested to receive the data. Managing IPv4 and IPv6 Multicast 1237 Figure 42-54. IPv4 Multicast VLAN Routing Video Server L3 Switch A (PIM RP) Port 23 Port 24 L3 Switch B L3 Switch C IGMP Join IGMP Join ` ` ` VLAN 10 Members ` VLAN 20 Members In addition to multicast configuration, this example includes commands to configure STP and OSPF on L3 Switch A. STP is configured on the ports that connects the switch to other switches. OSPF is configured to route unicast traffic between the VLANs and PIM is enabled to rout multicast traffic between the two VLANs. Since IGMP snooping is enabled by default on all VLANs, no commands to enable it appear in the example below. To configure Switch A: 1 Create the two VLANs. IGMP/MLD Snooping is disabled globally. 1238 Managing IPv4 and IPv6 Multicast console#configure console(config)#no ip igmp snooping console(config)#no ipv6 mld snooping console(config)#vlan 10,20 console(config-vlan10,20)#exit 2 Configure port 23 and 24 as trunk ports. console(config)#interface gi1/0/23 console(config-if-Gi1/0/23)#switchport mode trunk console(config-if-Gi1/0/23)#switchport trunk allowed vlan remove 10 console(config-if-Gi1/0/23)#exit console(config)#interface gi1/0/24 console(config-if-Gi1/0/24)#switchport mode trunk console(config-if-Gi1/0/24)#switchport trunk allowed vlan remove 20 console(config-if-Gi1/0/24)#exit 3 Enable routing on the switch and configure the OSPF router ID. console(config)#ip routing console(config)#router ospf console(config-router)#router-id 3.3.1.1 console(config-router)#exit 4 Configure VLAN 10 as a VLAN routing interface and specify the OSPF area. When you assign an IP address to the VLAN, routing is automatically enabled. console(config)#interface vlan 10 console(config-if-vlan10)#ip address 192.168.10.4 255.255.255.0 console(config-if-vlan10)#ip ospf area 0 5 Enable IGMPv2 and PIM-SM on the VLAN routing interface. console(config-if-vlan10)#ip igmp console(config-if-vlan10)#ip igmp version 2 console(config-if-vlan10)#ip pim console(config-if-vlan10)#exit 6 Configure VLAN 20 as a VLAN routing interface and specify the OSPF area. console(config)#interface vlan 20 console(config-if-vlan20)#ip address 192.168.20.4 255.255.255.0 console(config-if-vlan20)#ip ospf area 0 7 Enable IGMPv2 and PIM-SM on the VLAN routing interface. console(config-if-vlan20)#ip igmp console(config-if-vlan10)#ip igmp version 2 console(config-if-vlan20)#ip pim Managing IPv4 and IPv6 Multicast 1239 console(config-if-vlan20)#exit 8 Globally enable IP multicast, IGMP, and PIM-SM on the switch. console(config)#ip multicast console(config)#ip igmp console(config)#ip pim sparse 9 Configure VLAN 10 as the RP and specify the range of multicast groups for PIM-SM to control. The 239.9.x.x address is chosen as it is a locally administered address that maps to MAC addresses that do not conflict with control plane protocols. console(config)#ip pim rp-address 192.168.10.4 239.9.0.0 255.255.0.0 1240 Managing IPv4 and IPv6 Multicast Configuring DVMRP The following example configures two DVMRP interfaces on the switch to enable inter-VLAN multicast routing. To configure the switch: 1 Globally enable IP routing and IP multicast. console#configure console(config)#ip routing console(config)#ip multicast 2 Globally enable IGMP so that this L3 switch can manage group membership information for its directly-connected hosts. Enabling IGMP is not required if there are no directly-connected hosts; however, it is recommended that it be enabled to ensure correct operation of multicast routing. Disable IGMP/MLD snooping. console(config)#ip igmp console(config)#no ip igmp snooping console(config)#no ipv6 mld snooping 3 Globally enable DVMRP. console(config)#ip dvmrp 4 Enable DVMRP and IGMP on VLAN routing interfaces 10 and 20. console(config)#interface vlan 10 console(config-if-vlan10)#ip address 192.168.10.1 255.255.255.0 console(config-if-vlan10)#ip dvmrp console(config-if-vlan10)#ip igmp console(config-if-vlan10)#exit console(config)#interface vlan 20 console(config-if-vlan20)#ip address 192.168.20.1 255.255.255.0 console(config-if-vlan20)#ip dvmrp console(config-if-vlan20)#ip igmp console(config-if-vlan20)#exit Managing IPv4 and IPv6 Multicast 1241 1242 Managing IPv4 and IPv6 Multicast System Process Definitions 43 The following process/thread definitions are intended to assist the end user in troubleshooting switch issues. Only the most often seen threads/processes are listed here. Other processes or threads may be seen occasionally but are not a cause for concern. Table 43-1. System Process Definitions Name Task Summary aclClusterTask ACL tasks aclEventTask aclLogTask ARP Timer ARP tasks autoInstTask Auto Install task - USB, etc. bcmATP-RX BCM system task: Acknowledged Transport Protocol bcmATP-TX bcmCNTR.0 BCM system task: SDK Statistics collection bcmDISC BCM system task: SDK Discovery task bcmDPC BCM system task: SDK DPC task bcmL2X.0 BCM system task: SDK L2 SOC shadow table maintenance bcmLINK.0 BCM system task: SDK Physical link status monitor bcmNHOP BCM system task: SDK transport Next Hop task bcmRLINK BCM system task:SDK Remote registration last bcmRPC BCM system task:SDK Remote registration last bcmRX BCM system task: SDK Control plane packet receiver/dispatcher bcmTUNQ BCM system task: SDK transport queueing task bcmTX BCM system task: SDK Control plane packet transmitter System Process Definitions 1243 Table 43-1. System Process Definitions (Continued) Name Task Summary bcmXGS3AsyncTask BCM system task: SDK XGX3 hw task BootP Boot Loader boxs Req Box Services Request (temperature, power, fan) boxs Resp Box Services Response (temperature, power, fan) boxs Timer Box Services Response (temperature, power, fan) cdaFftpTask Code Distribution Administrator FTP task cdaStatusTask Code Distribution Administrator Status task cdaUpdateTask Code Distribution Administrator Update task cliWebIORedirectTask CLI Web IO Redirection Task cmgrInsertTask Card Manager Insertion Handler cmgrTask Card Manager Status (built-in and plug-in card configuration processing) Cnfgr_Thread Configurator (startup manager) CP Wired If Captive Portal cpuUtilMonitorTask CPU Utilities monitor DapiDebugTask Device API debug processing DHCP Server Processing Task DHCP Tasks DHCP snoop dhcpsPingTask DHCPv4 Client Task DHCPv6 Client Task DHCPv6 Server Task dnsRxTask DNS tasks dnsTask dosTask Denial of Service task dot1qTask VLAN routing task 1244 System Process Definitions Table 43-1. System Process Definitions (Continued) Name Task Summary Dot1s transport task Spanning Tree tasks dot1s_helper_task dot1s_task dot1s_timer_task dot1xTask 802.1x authentication tasks dot1xTimerTask dot3ad_core_task Link aggregationt tasks dot3ad_core_ac_task dot3ad_helper_task dot3ad_timer_task dtlAddrTask Device Transform Layer - Silicon Integration Layer dtlTask dvmrpMapTask DVMRP Mapping Layer Dynamic ARP Inspection Dynamic ARP Inspection task EDB Entity MIB Processing task EDB Trap Entity MIB Trap task emWeb UI processing task envMonTask Environment Monitor (fans, power supplies, temperature, …) fdbTask Forwarding Data Base Manager fftpTask FTP processing gccp_t GARP Central Control Point task (dot 1d) System Process Definitions 1245 Table 43-1. System Process Definitions (Continued) Name Task Summary hapiBpduTxTask High Level API - SDK Integration Layer hapiL2AsyncTask hapiL2FlushTask hapiL3AsyncTask hapiLinkStatusTask hapiMcAsyncTask hapiRxTask hapiTxTask hpcBroadRpcTask SDK Remote messaging task. ip6MapExceptionDataTask IP Stack ip6MapLocalDataTask ip6MapNbrDiscTask ip6MapProcessingTask ip6MapRadvdTask ipcom_sysl IpHelperTask ipMapForwardingTask ipMapProcessingTask ipnetd iscsiTask ISCSI task isdpTask ISDP task lldpTask LLDP task LOG System LOG processing LOGC System LOG processing MAC Age Task MAC address table aging MAC Send Task MAC address table learning macalTask Management ACL packet processing 1246 System Process Definitions Table 43-1. System Process Definitions (Continued) Name Task Summary mcastMapTask Multicast Mapping Tasks mgmdMapTask mvrTask MVR Message Handler nim_t Network Interface Manager osapiMonTask System Task Monitor osapiTimer Application timer service osapiWdTask Hardware watchdog timer service OSPF mapping Task OSPF tasks OSPF Proto OSPFV3 mapping Task OSPFV3 recvmsg Task OSPFv3 Proto pimdmMapTask PIMDM task pimsmMapTask PIMSM task pingAsync Ping response processing pktRcvrTask Multicast control plane packet receiver/dispatch pmlTask Port MAC Locking management task portAggTask Port Aggregator task radius_rx_task RADIUS server tasks radius_task ripMapProcessingTask RIP Mapping layer RLIM cnfgr task VRRP configuration RLIM task VRRP message processing RMONTask RMON Statistics Collection serialInput Serial Input task sFlowTask sFlow task SimAddrConflictTask System Interface Manager Address Conflict Task System Process Definitions 1247 Table 43-1. System Process Definitions (Continued) Name Task Summary simPts_task System Interface Manager (time zone, system name, service port config, file transfers, ...) SNMPCTTask SNMP Tasks SNMPSaveCfgTask SNMPTask SNMPTrapTask snoopTask IGMP/MLD Snooping packet processing SNTP SNTP tasks SNTPC spmTask Stack port manager - stacking control plane packet processing sshdEvTask SSH task ssltTask SSL task Stk Mgr Task Stack Manager Task tacacs_rx_task TACACS tasks tacacs_task tArpCallback ARP tasks tArpReissue tArpTimerExp ARP Timer Expiry tCpktSvc NSF Processing tCptvPrtl Captive portal control plane processing tDhcp6sTask DHCP Tasks tDhcpsTask tEmWeb Web page server tErfTask VxWorks Task tExcTask VxWorks Executive TimeRange Processing Task ACL Time Ranges tIomEvtMon 1248 CMC Communication System Process Definitions Table 43-1. System Process Definitions (Continued) Name Task Summary tJobTask VxWorks Task tL7Timer0 System Timer tLogTask System LOG processing tNet0 VxWorks Network driver TransferTask TFTP Processing trapTask Trap handler tRipTask RIP Routing tRtrDiscProcessingTask Router Discovery packet processing tTffsPTask VxWorks True Flash File System driver tXbdService VxWorks flash file system load leveler usbFlashDriveTask USB Flash driver processing umCfgUpdateTask Stack Management: Unit Manager tasks umWorkerTask unitMgrTask USL Worker Task USL Message processing (primarily MAC address table CLI commands) UtilTask Mgmt. UI login/logout processing voipTask Voice Over IP VRRPdaemon VRRP task System Process Definitions 1249 1250 System Process Definitions Index Numerics 802.1p see CoS queuing ACLs. See also IP ACL, IPv6 ACL, and MAC ACL. active images, 327 address table. See MAC address table. A AAA, 175 access lines, 197 access profiles, 58 accounting, 180 ACL for controlling management access, 556 ACLs Auto-Voip usage, 1148 binding configuration, 540 CLI configuration, 543 configuration steps, 528 defined, 523 examples, 551 iSCSI usage, 405 limitations, 527 logging, 526 management control, example, 558 preventing false matches, 528 supported types, 62 time-based, 555 web-based configuration, 530 administrative profiles, 179 defaults, 198 RADIUS authorization, 189 TACACS+ authorization, 186 ARP, 76 dynamic ARP inspection, 63 ARP inspection. see DAI. ARP table configuring (CLI), 900 configuring (web), 890 authentication, 177 examples, 181 authentication key, SNTP, 253 authentication profiles, 58 authentication server filter assignments, 513 authorization, 178 administrative profiles, 179 examples, 185 RADIUS, 189 auto configuration auto save, 355 CLI configuration, 359 Index 1251 defaults, 357 defined, 345 DHCP, 362 configuration file, 353 image, 352 IP address, obtaining, 351 example, 360 files setup file, 349 USB, 346 files, managing, 355 IP address lookup, 348 MAC address lookup, 348 stopping, 355 using a USB device, 360 using DHCP, 350 web-based configuration, 358 auto image download DHCP, 362 USB, 360 auto install, 55 auto install. See auto configuration. auto negotiation, 68 auto save feature, 355 auto VoIP CLI configuration, 1152 defaults, 1148 understanding, 1147 web-based configuration, 1149 auto-provisioning, iSCSI, 407 Auto-VoIP and ACLs, 1148 1252 Index B back panel features, 90 back pressure, 67 banner, CLI, 276 baud rate, 89 BOOTP/DHCP relay agent, 77 BPDU filtering, 74, 636 flooding, 636 guard, 74 protection, 638 bridge multicast address groups, configuring, 717 bridge multicast group table, 716 bridge table, 837 broadcast storm control. See storm control. C cable test, 201, 212 and green mode, 212, 462 captive portal, 61 CLI configuration, 447 client management, 452 configuring, 454 customizing pages, 423 defaults, 424 defined, 419 dependencies, 420 design considerations, 421 example, 453 localization, 423 understanding, 419, 422 user logout mode, 423 users, RADIUS server, 435 web-based configuration, 426 defined, 321 DHCP auto configuration, 353 downloading, 324 editing, 324 SNMP, 325 USB auto configuration, 349 USB device, 343 cards configuration, 261 supported, 263 configuration scripts, 324, 341 CDP, interoperability through ISDP, 56 Configuring, 859 certificates, 322 CFM, 761 checkpointing, 148 Cisco protocol filtering, 70 CLI accessing the switch, 109 banner, 239 command completion, 114 command modes, 111 command prompt, 241 error messages, 115 negating commands, 114 CLI banner, configuring, 276 clock, system, 251 command modes, CLI, 111 commands abbreviated, 114 entering, 113 history buffer, 115 Compellent storage arrays, 408 configuration, saving the, 325 connectivity fault management. See IEEE 802.1ag. console port connecting to, 109 description, 89 LED, 98 copy, files, 333 CoS and iSCSI, 404 CLI configuration, 1140 configuration example, 1144 defaults, 1132 defined, 1129 queue management methods, 1131 traffic queues, 1131 traffic shaping, 1130 trusted mode ports, 1130 untrusted mode ports, 1130 web-based configuration, 1133 CoS queuing CX-4 module, 243 configuration file Index 1253 D DAI defaults, 787 optional features, 786 purpose, 787 understanding, 786 data center and DHCP snooping, 815 and NSF, 168 SDM template, 241 date, setting, 271 daylight saving time, 240 default gateway, configuring, 123, 129 default VLAN, 136 DHCP client, 134 IP address configuration, 127 denial of service, 60, 521 device discovery protocols, 660 device view, 108 DHCP understanding, 859 DHCP auto configuration dependencies, 356 enabling, 362 monitoring, 355 process, 350 DHCP client, 861 default VLAN, 134 OOB port, 134 DHCP relay, 70, 861 CLI configuration, 925 1254 Index defaults, 913 example, 929 layer 2, 908 layer 3, 907 understanding, 907 VLAN, 909 web-based configuration, 914 DHCP server, 54 address pool configuration, 878 CLI configuration, 874 defaults, 861 examples, 878 leases, 135 options, 860 web-based configuration, 862 DHCP snooping, 63, 861 bindings database, 783 defaults, 787 example, 815 logging, 784 purpose, 787 understanding, 782 VLANs, 784 DHCPv6 client, 1066 defined, 79 examples, 1097 pool, 1082 prefix delegation, 1082 relay agent, configuring, 1099 relay agent, understanding, 1082 stateless server configuring, 1097 stateless server, understanding, 1082 authentication, 178 understanding, 1081 dhcpv6, 1081 double-VLAN tagging, 566 DHCPv6 pool stateless server support, 1093 downloading files, 329 DHCPv6 relay CLI configuration, 1093 defaults, 1083 web-based configuration, 1084 dual images, 54 DHCPv6 server CLI configuration, 1093 prefix delegation, 1098 web-based configuration, 1084 DVMRP, 83 defaults, 1171 example, 1241 understanding, 1169 web-based configuration, 1212 when to use, 1170 DHCPv6 server relay defaults, 1083 DiffServ and 802.1X, 489 and RADIUS, 489 and switch role, 1102 CLI configuration, 1116 defaults, 1103 elements, 1102 example, 1123 understanding, 1101 VoIP, 1126 web-based configuration, 1104 DSCP value and iSCSI, 405 dual IPv4 and IPv6 template, 241 duplex mode, 89 dynamic ARP inspection, 63 dynamic LAGs, 834 dynamic VLAN creation, 512 E EAP statistics, 376 email alert statistics, 225 diffServ, 80 email alerting, 234 log messages, 231 discovery, device, 659 enable authentication, 178 document conventions, 50 energy detect mode, 65, 458 domain name server, 130 Energy Efficient Ethernet, 65 domain name, default, 131 energy savings, port, 458 Dot1x, 61 EqualLogic and iSCSI, 407 dot1x error messages, CLI, 115 Index 1255 EtherType numbers, common, 528 firmware synchronization, stacking, 146 exec authorization, 179 expansion slots, 92, 243 flow control configuring, 698 default, 690 understanding, 688 F flow-based mirroring, 1115 failover, 58 forwarding database, 837 and port security, 785 failover, stacking, 148 false matches, ACL, 528 FCoE configuring CoS queues for, 1145 file management CLI, 334 considerations, 323 copying, 333 purpose, 321 supported protocols, 323 web-based, 326 file system, 326 files and stacking, 325 downloading to the switch, 323 types, 319 uploading from the switch, 323 filter assignments, authentication server, 513 filter, DiffServ, 489 firmware managing, 323 updating the stack, 146 upgrade example, 338 1256 Index front panel features, 85 G GARP, 709 GARP and GVRP, 71 GMRP, 709 green Ethernet, 458, 462 green features, 65 guest VLAN, 486 VLAN guest, 511 GVRP, 566 statistics, 375 H head of line blocking prevention, 66 health, system, 209 help, accessing web-based, 113 host name, 239 host name mapping, 122 I IAS database, 496 understanding, 489 users, 503 icons, web-based interface, 106 identification asset tag, 239 system contact, 239 system location, 239 system name, 239 IDSP defaults, 661 IEEE 802.1ag administrator, 765 carrier network, 762 configuration (CLI), 775 configuration (web), 767 defaults, 766 defining domains and ports, 765 example, 778 MEPs and MIPs, 763 troubleshooting tasks, 766 understanding, 761 IEEE 802.1d, 73 IEEE 802.1Q, 71 IEEE 802.1X, 61 and DiffServ, 489 authentication, 61 configuring, 503 defined, 482 monitor mode, 62, 487, 500 port authentication, 498 port states, 483 RADIUS-assigned VLANs, 501 reauthenticating ports, 492 VLAN assignment, 485 IEEE 802.1x authentication, 178 IEEE 802.3x. See flow control. IGMP, 83 defaults, 1171 understanding, 1157 web-based configuration, 1181 IGMP proxy, 83, 1157 IGMP snooping, 81 defaults, 713 querier, 82 querier, defined, 706 understanding, 705 image activating, 334 auto configuration, 352 auto install, 349 considerations, 323 defined, 319 downloading, 334 management, CLI, 334 management, web-based, 326 purpose, 321 in-band management, 123 interface, 843 configuration mode, 460 Index 1257 loopback, 844 OOB, 126 routing, 843 CLI configuration, 855 web configuration, 849 routing defaults, 848 supported types, 460 tunnel, 845 internal authentication server, see IAS IP ACL configuration, 530 defined, 525 example, 551 IP address configuring, 123 default, 125 default VLAN, 127, 136 OOB port, 136 IP helper, 77, 909 IP multicast traffic layer 2, 704 layer 3, 1154 and port security, 785 example, 817 purpose, 787 understanding, 785 IPv4 and IPv6 networks, interconnecting, 1006 IPv4 multicast web-based configuration, 1173 IPv4 routing template, 241 IPv6 compared to IPv4, 1058 DHCP client, 1066 DHCPv6, 79 OSPFv3, 79 routes, 79 static reject and discard routes, 1078 tunnel, 78 IPv6 ACL configuration, 537 IPv6 interface configuring, 1058 IPv6 management, 54 IP protocol numbers, common, 529 IPv6 multicast web-based configuration, 1180 IP routing CLI configuration, 899 defaults, 885 example, 904 understanding, 883 web-based configuration, 887 IPv6 routing CLI configuration, 1071 defaults, 1059 features, 78 understanding, 1057 web-based configuration, 1061 IP source guard, 63 IRDP, configuring, 901 IPSG iSCSI 1258 Index ACL usage, 405 and Compellent storage arrays, 408 and CoS, 404 and Dell EqualLogic arrays, 407 assigning flows, 404 CLI configuration, 414 defaults, 409 examples, 416 flow detection, 404 information tracking, 405 servers and a disk array, 416 understanding, 403 using, 404 web-based configuration, 410 ISDP and CDP, 56 CLI configuration, 678 configuring, 679 enabling, 679 example, 683 understanding, 659 web-based configuration, 663 J jumbo frames, 67 L LACP, 74 adding a LAG port, 828 CLI configuration, 833 web-based configuration, 825 LAG and STP, 822 CLI configuration, 830 defaults, 823 examples, 834 guidelines, configuration, 823 interaction with other features, 822 LACP, 74 purpose, 820 static and dynamic, 820 statistics, 390 threshold, minimum links, 830 understanding, 819 web-based configuration, 824 LAG hashing, 821 languages, captive portal, 423 LED 10 Gigabit Ethernet port, 97 100/1000/10000Base-T port, 95 locator, 94 OOB port, 98 plug-in modules, 97 port, 90 SFP port, 96 SFP+ port, 97 stack master, 90 system, 99 link aggregation group. See LAG. link dependencies CLI configuration, 476-477 creating, 467 example, 480 scenarios, 459 Index 1259 understanding, 458 web configuration, 467 link local protocol filtering, see LLPF LLDP CLI configuration, 678 defaults, 661 example, 684 understanding, 659 web-based configuration, 663 LLDP-MED and voice VLANs, 570 configuring, 682 understanding, 660 viewing information, 683 LLPF defaults, 690 example, 701 understanding, 689 localization, captive portal, 423 locating the switch, 108 locator LED, 94 enabling, 108, 226 log messages, 53 log server, remote, 218 logging ACL, 526 CLI configuration, 226 considerations, 205 defaults, 205 destination for log messages, 202 example, 233 file, 217 1260 Index log message format, 204 operation logs, 203 severity levels, 203 system startup logs, 203 trap log, 304 web-based configuration, 207 loopback, 78 loopback interface configuring, 857 purpose, 847 understanding, 844 low-power idle, 462 LSA, OSPF, 933 M M6348 and stacking, 143 MAC ACL example, 553 understanding, 524 MAC address table and port security, 785 contents, 838 defaults, 838 defined, 837 dynamic, 841 managing, CLI, 842 populating, 837 stacking, 838 web-based management, 839 MAC multicast support, 81 MAC port locking, 518 MAC-based 802.1X authentication understanding, 484 MAC-based VLAN, 564 mail server adding, 221 configuring, 230 email alert, 221 management access control list, 556 access control using RADIUS, 190 access control using TACACS+, 195 management access list, example, 558 management, in-band and out-of-band, 123 MD5, 242 MDI/MDIX, auto, 67 MEP, configuring, 776 MIB, SNMP, 283 Microsoft Network Load Balancing, 1170 mirror, ACL, 525 mirroring, flow-based, 1115 MLD, 84 defaults, 1171 understanding, 1158 web-based configuration, 1190 MLD snooping, 82 defaults, 713, 787 understanding, 707 VLAN configuration, 750 mode interface configuration, 460 module, CX-4, 243 modules, supported, 92 monitor mode, IEEE 802.1X, 487 monitoring system information, 201 MSTP example, 657 operation in the network, 631 support, 73 understanding, 629 MTU, configuring, 476 MTU, management interface, 124 Multicast VLAN registration, 82 multicast DVMRP, 83 IGMP, 83 IGMP proxy, 83 IGMP snooping, 81 IPv4, 1173 layer 2, 81 configuring (CLI), 747 configuring (web), 715 defaults, 713 understanding, 703 when to use, 709 layer 3, 83 Index 1261 CLI configuration, 1219 defaults, 1171 examples, 1237 understanding, 1153 when to use, 1156 MAC layer, 81 MLD snooping, 82 protocols roles, 1155-1156 VLAN Routing with IGMP and PIM-SM, 1237 NSF and DHCP snooping, 170 and routed access, 173 and the storage access network, 171 and VoIP, 169 in the data center, 168 network design considerations, 150 understanding, 147 multicast bridging, 703, 747 multicast protocols, supported, 1155 O multicast routing table, 1156 multicast snooping, 755 OOB port, 89, 126 DHCP client, 134 multicast VLAN registration, 708 OpenManage Switch Administrator, about, 103 MVR adding an interface, 739 optical transceiver diagnostics, 213 N netinfo, 121 network information CLI configuration, 134 default, 125 defined, 121 example, 138 purpose, 122 web-based configuration, 126 network pool, DHCP, 865 nonstop forwarding, see NSF 1262 Index OAM, 761 OSPF, 76 areas, 932 border router, 997 CLI configuration, 975 defaults, 940 difference from OSPFv3, 933 examples, 997 flood blocking, 938, 1014 LSA pacing, 937 NSSA, 1000 static area range cost, 936, 1009 stub area, 1000 stub routers, 934 topology, 932 trap flags, 302 understanding, 932 web-based configuration, 942 OSPFv3, 79 CLI configuration, 987 difference from OSPF, 933 global settings, 987 interface settings, 989 NSSA, 1000 stub area, 1000 trap flags, 303 web-based configuration, 958 out of band port, IP address, 136 out-of-band management, 123 P password protecting management access, 59 strong, 59 PIM defaults, 1171 IPv4 web-based configuration, 1200 IPv6 web-based configuration, 1200 PIM-DM, using, 1168 PIM-SM, using, 1159 SSM range, 1208 understanding, 1159 plug-in modules, 92 configuring, 243 PoE+, 243, 273 port access control, 494 characteristics, 457 configuration examples, 479 configuring multiple, 465 defaults, 463 defined, 457 device view features, 108 example, 479 LEDs, 90 locking, 518 OOB, 89 power saving, 462 protected, 64, 694, 699 statistics, 389 traffic control, 687 USB, 89 port channel. See LAG. port characteristics CLI configuration, 475 web-based configuration, 464 port control, 493 port fast, STP, 636 port mirroring configuring, 391 mode, enabling, 368 understanding, 367 port security configuring, 520 MAC-based, 62 understanding, 517 port-based traffic control CLI configuration, 698 web-based configuration, 691 Index 1263 port-based VLAN, 564 RAM log, 216 port-MAC locking, 62 see port security real time clock, 240 power supplies, 93 relay agent, DHCPv6, 1082 power utilization reporting, 65 relay, DHCP, 907 power, per-port saving modes, 462 remote logging, 229 private VLAN edge, 64 private VLANs, 570, 626 protected port defined, 689 example, 701 protocol filtering, Cisco, 70 protocol-based VLAN, 564 Q QoS CoS queuing diffserv, 80 queues, CoS, 1131 redirect, ACL, 525 reset button, 90 RIP, 77 CLI configuration, 1027 defaults, 1021 determining route information, 1019 example, 1031 supported versions, 1020 understanding, 1019 web-based configuration, 1022 RMON, 56 CLI management, 393 defaults, 368 example, 401 understanding, 366 web-based configuration, 369 router discovery, 901 router discovery protocol, 77 R RADIUS, 59 and DiffServ, 489 authentication, 184 authorization, 189 for management access control, 190 supported attributes, 192 understanding, 190 1264 Index router, OSPF, 933 routes IPv4, 897 IPv6, 1070 selecting, 933 Routing table, 77 routing defaults (IPv4), 885 defaults (IPv6), 1059 example, 904 IPv4, CLI configuration, 899 IPv4, web-based configuration, 887 IPv6, CLI configuration, 1071 IPv6, web-based configuration, 1061 understanding, 883 routing interfaces CLI configuration, 855 defaults, 848 understanding, 843 using, 846 web-based configuration, 849 security port, defined, 517 port-based CLI configuration, 498 defaults, 490, 517 examples, 503 web-based configuration, 491 setup file format, auto configuration, 349 sFlow, 56 CLI management, 393 defaults, 368 example, 399 understanding, 363 web-based management, 369 SFP port LEDs, 96 routing table best routes, 894 configuring, 902 IPv6, 1075, 1077 SFP+ port LEDs, 97 RSTP understanding, 629 SNMP CLI configuration, 305 defaults, 285 examples, 314 MIB, 283 purpose, 285 traps, 284 understanding, 283 uploading files, 325 web-based configuration, 287 running-config, saving, 325 S save, system settings, 325 SDM template configuration guidelines, 242 managing, 269 understanding, 241 SDM templates, 55 SFTP, managing files, 337 slots, 92, 243 SNMPv1 example, 314 SNMPv2 example, 314 SNMPv3 Index 1265 engine ID, 305 example, 315 SNTP authentication, 269 authentication key, 253 example, 279 server, 269 server configuration, 256 understanding, 242 NSF usage scenario, 163 preconfiguration, 166 purpose, 151 removing a switch, 146 standby, 147 switch compatibility, 143 web-based configuration, 152 static reject route, 884 software image, 319 statistics IPv6, 1064 spanning tree. See STP. statistics, Etherlike, 374 split horizon, 1020 storage arrays and iSCSI, 407 SSH files, 322 storage arrays, Compellent, 408 SSH/SSL, 60 stack master LED, 90 storm control configuring, 698 default, 690 example, 701 understanding, 688 stacking adding a switch, 145 and NSF, 58 CLI configuration, 161 defaults, 151 defined, 141 design consideration, 150 failover, 58 failover, example, 164 failover, initiating, 148 features, 57 file management, 325 firmware synchronization, 146 firmware update, 146 MAC address table, 838 MAC addresses, 150 STP and LAGs, 822 classic, 629 CLI configuration, 650 defaults, 639 defined, 629 examples, 655 loop guard, 637 MSTP, 73 optional features, 636 port fast, 636 port settings, 73 root guard, 637 RSTP, 73 understanding, 630 web-based configuration, 640 SSL files, 322 SSM range, 1208 1266 Index subnet mask, configuring, 123 time domain reflectometry, 212 subnet-based VLAN, 564 time management, 52 summer time, 240 time range, 549 switch ports, 88 time zone, 260 switchport modes, VLAN, 564 time, setting the system, 281 switchport statistics, web view, 379 time-based ACLs, 526, 555 system health, monitoring, 207 traffic control port based, 687 system information CLI configuration, 267 default, 245 defined, 239 example, 276 purpose, 240 web-based configuration, 246 system LEDs, 90 system time, 242 T TACACS+, 59 authentication, 182 authorization, 185-186 management access control, 195 supported attributes, 196 understanding, 195 traffic class queue, 404 traffic inspection, 781 traffic monitoring, 363 traffic snooping, 781 traps OSPF, 302 trunk port and 802.1X authentication, 511, 513 trunking, 600 tunnel, 78 tunnel interfaces, 845 U UDP relay, 77, 909 tagging, VLAN, 565 upgrade, stack firmware, 57 telnet configuration options, 60 connecting to the switch, 110 uploading files, 331 TFTP, image download, 334 USB auto configuration example, 360 files, 346, 348 understanding, 346 Index 1267 USB flash drive, example, 343 USB port, 89 user security model, SNMP, 284 users authenticated, 493 captive portal, 432 IAS database, 489 USM, 284 switchport modes, 564 trunk port, 600 understanding, 561 voice, 71, 569 voice traffic, 569 voice, example, 625 voice, understanding, 568 web-based configuration, 579 VLAN membership, defining, 579 V VLAN priority tag and iSCSI, 405 ventilation system, 94 VLAN routing, 843, 846 virtual link, OSPF, 1004 VLAN tagging, 565 VLAN, 822 authenticated and unauthenticated, 485 CLI configuration, 599 defaults, 577 double, 72 double-VLAN tagging, 566 dynamic, 486 example, 616, 621 guest, 72, 486, 512 IP subnet-based, 71 MAC-based, 71, 564 port-based, 70, 564 private, 570, 626 protocol-based, 71, 564 RADIUS-assigned, 512 routing, 76 routing interfaces, 843, 855 static, 564 support, 70 VLANs dynamically created, 512 RADIUS-assigned, 512 1268 Index voice traffic, identifying, 569 voice VLAN, 569 and LLDP-MED, 570 example, 625 understanding, 568 VoIP, 80 VoIP and DiffServ, 1126 VoIP, auto, 1147 VRRP, 78 accept mode, 1035 CLI configuration, 1046 defaults, 1037 example, 1048 interface tracking, 1035 load sharing example, 1048 preemption, 1034 route and interface tracking example, 1052 route tracking, 1035 router priority, 1034 understanding, 1033 web-based configuration, 1038 W web-based configuration, 104 web-based interface, understanding, 105 writing to memory, 325 Index 1269 Index 1270


Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Format                          : application/pdf
Creator                         : Dell Inc.
Subject                         : User's Guide
Description                     : User's Guide
Title                           : User’s Configuration Guide
Producer                        : Acrobat Distiller 9.4.2 (Windows); modified using iTextSharp 5.1.3 (c) 1T3XT BVBA
Keywords                        : Servers, Storage & Networking#PowerConnect#powerconnect 7024#powerconnect-7024#powerconnect 7024f#powerconnect-7024f#powerconnect 7024p#powerconnect-7024p#powerconnect 7048#powerconnect-7048#powerconnect 7048p#powerconnect-7048p#powerconnect 7048r#powerconnect-7048r#User's Guide#Dell PowerConnect 7000 Series Switch User’s Configuration Guide
Create Date                     : 2013:01:22 11:23:57Z
Creator Tool                    : FrameMaker 10.0.2
Modify Date                     : 2013:04:02 06:05:35-05:00
Page Mode                       : UseOutlines
Page Count                      : 1270
Author                          : Dell Inc.
Productcode                     : powerconnect-7024#powerconnect-7024f#powerconnect-7024p#powerconnect-7048#powerconnect-7048p#powerconnect-7048r
Typecode                        : ug
Typedescription                 : User's Guide
Languagecodes                   : en-us
Publishdate                     : 2013-04-02 00:00:00
Expirydate                      : 9999-09-09 00:00:00
Manualurl                       : http://ftp.dell.com/manuals/commonfolder/powerconnect-7024_User's Guide_en-us.pdf
Readytocopy                     : false
Isdeleted                       : False
Businesskeywords                : Dell PowerConnect 7000 Series Switch User’s Configuration Guide
Futureproductindication         : No
Categorypathforfutureproducts   : 
Filesize                        : 35814
Creationdate                    : D:20130122112357Z
Moddate                         : D:20130402020530-05'00'
EXIF Metadata provided by EXIF.tools

Navigation menu