This document describes the new features, enhancements, fixed issues, and open issues in Storage Center 7.1.
Current Version: 7.1.20
Release Date: 2017 - 07
Previous Version: 7.1.12

Contents
Document Revision History......................................................................................................................................................1
Supported Storage Systems................................................................................................................................................... 2
New in This Release................................................................................................................................................................ 2
Storage Center 7.1 Feature Availability and Licenses................................................................................................................5
Storage Center 7.1 Scalability...................................................................................................................................................9
Fixed Issues............................................................................................................................................................................ 11
Open Issues........................................................................................................................................................................... 21
Storage Center Update Information...................................................................................................................................... 24
Support Resources............................................................................................................................................................... 24

Document Revision History
Document Number: 680-021-019
Revision

Date

Description

A

August 2016

Initial release of Storage Center 7.1

B

September 2016

Updated for Storage Center 7.1.2

C

September 2016

Updated feature support for SC7020

D

November 2016

Updated for Storage Center 7.1.3

E

December 2016

Updated for Storage Center 7.1.4

F

January 2017

Updated Storage Center scalability guidelines

G

April 2017

Updated for Storage Center 7.1.12

H

April 2017

Updated the description of a fixed issue in Storage Center 7.1.12

I

July 2017

Updated for Storage Center 7.1.20

J

July 2017

Updated the issues fixed in Storage Center 7.1.20

Document Number: 680-021-019
Rev. J
2017 - 07

Supported Storage Systems
Storage Center 7.1 is supported on the following storage systems:
•

SC9000

•

SC8000

•

SC7020

•

SC4020

•

SCv2000 series

New in This Release
The following features were added to Storage Center 7.1.

Dell Storage Manager 2016 R2
Dell Storage Manager 2016 R2 is required to manage storage systems running Storage Center 7.1.
Storage Center 7.1 no longer supports the browser-based GUI known as Storage Center System Manager
You must install Dell Storage Manager 2016 R2 before updating a storage system to Storage Center 7.1. If you update a storage
system to Storage Center 7.1 without using Dell Storage Manager 2016 R2, you will lose management connectivity to the storage
system.
NOTE: The storage system must be running Storage Center 6.6.4 or later to update to Storage Center 7.1.

SC7020 Storage System
Storage Center 7.1 introduces support for the SC7020 storage system.
The SC7020 consists of a 3U chassis with dual storage controllers, redundant power supplies, and up to 30 2.5-inch hot swappable
SAS hard drives. The SC7020 can be expanded up to 500 drives and it supports SC400 and SC420 12 Gb expansion enclosures and
SC280 6 Gb expansion enclosures.
NOTE: Support for upgrading a storage system with SC200 and SC220 expansion enclosures to an SC7020 storage
system is planned for a later release.

SC4020 Storage Systems with Front-End SAS Connectivity
Storage Center 7.1 adds support for SC4020 storage system models with front-end SAS I/O cards.
NOTE: An SC4020 storage system with front-end SAS connectivity does not support the Live Volume feature in Storage
Center 7.1.

32 Gb FC I/O Card Support
Storage Center 7.1 adds support for a 32 Gb Fibe Channel I/O card.
Support for the 32 Gb Fibre Channel I/O card is currently limited to SC9000 storage systems with a specific configuration of
switches and operating systems. See the Dell Storage Compatibility Matrix for more information.

4Kn Drive Support
Storage Center 7.1 adds support for native 4K sector drives.
Native 4K drives use a 4096-byte sector size instead of the legacy 512-byte sector size.

2

Dell Storage Center 7.1 Release Notes

Cross-Platform Replication
The cross-platform replication feature provides a method for performing volume replication between PS Series storage arrays and
Storage Centers. This feature preserves the functional and operational models in the current replication implementation for each
storage system.
NOTE: SCv2000 series storage systems do not support cross-platform replication.

Data Center Bridging (DCB) Support
Storage Center 7.1 supports data center bridging (DCB) services.
Dell Storage Manager displays DCB information for supported I/O cards, such as switch names and features of the switch port that
an iSCSI port is plugged into. Dell Storage Manager also displays information about the Link Layer Discovery Protocol (LLDP), which
is used to help support DCB.

Data Progression Improvements
Storage Center includes changes to Data Progression that reduce the impact on Storage Center performance.
Data Progression runs daily at specified time and continues until all tasks are completed. If all the tasks are not completed, those
tasks are completed in the next Data Progression cycle.
NOTE: Data Progression still follows the schedule set on the Storage Center.

Data Reduction
Data Reduction uses compression and deduplication to decrease the amount of disk space used by volume data. Compression
reduces the amount of space used by a volume by encoding data. Deduplication finds duplicate data in pages then removes the
duplicate data, conserving the disk space that would be used by additional copies. When deduplication is used, compression is also
applied to a volume.

Drive Age Reporting
Storage Center 7.1 adds support for the Drive Age Reporting feature.
The age of each drive is displayed as Power On Time in Dell Storage Manager 2016 R2.

Federation Live Migrate
Storage Center 7.1 adds support for the Federation Live Migrate feature.
Federation Live Migrate allows for the online migration of a volume from one Storage Center to another Storage Center without
downtime or disruption to the host server.
NOTE: Federation Live Migrate is supported on SC9000, SC8000, SC7020, and SC4020 storage systems, but it is not
supported on SCv2000 series storage systems.

IPv6 Support for Fault Domains and Pinging
Storage Center 7.1 supports IPv6 addresses in iSCSI fault domains as well as other IPv6 features.
•

iSCSI fault domains can be created and modified to use ports with IPv6 addresses.

•

Dell Storage Manager 2016 R2 can display multiple IPv6 addresses for each physical port, as well as multiple discovered gateway
IPv6 addresses.

•

Ports can be pinged using an IPv4 or IPv6 address.
NOTE: Replications between Storage Center and PS Series groups do not support IPv6.

Dell Storage Center 7.1 Release Notes

3

Live Volume with Auto Failover in Microsoft Server Enviroments
Storage Center 7.1 adds support for the Live Volume with Auto Failover feature in Microsoft server environments.
Live Volume with Auto Failover is supported in Microsoft server environments including Windows Server 2012 and Windows Server
2012 R2. In addition, Live Volume with Auto Failover is supported on both Microsoft Hyper-V and Windows clustering environments
including Windows clustering on VMware hosts using physical mode raw device mappings (pRDMs).
NOTE: Live Volume with Auto Failover in Microsoft server environments is supported on SC9000, SC8000, SC7020 and
SC4020 storage systems, but it is not supported on SCv2000 series storage systems.

Online Import of Volumes from PS Series Storage Arrays
An online import creates a destination volume, maps it to the server, then migrates the data to the destination volume.
In Storage Center 7.1, performing an online import of volumes from PS Series storage arrays is supported on Red Hat Enterprise
Linux 7.x, VMware ESXi 5.5 or later, and Windows Server 2008 R2 or later.

Renaming Replays to Snapshots
Starting in this release, Replays are now called snapshots in the Dell Storage Manager Client.

SED Rekey
Storage Center 7.1 supports enhancements for managing self-encrypting drives (SED).
NOTE: The Self-Encrypting Drives feature must be licensed to use Secure Data.
The following features have been added in Dell Storage Manager 2016 R2:
•

You can specify a rekey interval for a Secure Disk folder. When that interval has been reached, a rekey is triggered on each disk in
the folder.
A Rekey checkbox has been added to the Edit Disk Folder Settings dialog box.

•

You can perform an on-demand rekey of a Secure Disk folder.
A new option called Rekey Disk Folder has been added to the Disks menu when a Secure Data folder is selected.

•

The process called Rescue Data allows you to copy volumes from a Secure Data folder to another folder. The target folder can be
either a secure folder or a nonsecure folder. Use the Copy Volumes to Disk Folder operation to perform rescue data.

SNMPv3 Support
Storage Center 7.1 supports the use of SNMPv3 and the configuration of SNMPv3 users and trap destinations using Dell Storage
Manager 2016 R2.

Storage Redundancy Levels
The storage redundancy recommendations and requirements for HDDs and SSDs have changed in Storage Center 7.1.
NOTE: For SC7020 storage systems, the dual redundancy level is the default for all drives.
Table 1. HDD Redundancy Recommendations and Requirements

Disk Size

Redundancy Level

Up to 966 GB

No recommended or required redundancy level when adding disks of this size to a new or existing
page pool

967 GB to 1.9 TB

Dual redundancy is recommended when adding disks of this size to a new or existing page pool

2.0 TB or larger

Dual redundancy is required when adding disks of this size to a new page pool

4

Dell Storage Center 7.1 Release Notes

Disk Size

Redundancy Level

2.79 TB or larger

Dual redundancy is required when adding disks of this size to an existing page pool

Table 2. SSD Redundancy Recommendations and Requirements

Disk Size

Redundancy Level

Up to 1.7 TB

No recommended or required redundancy level when adding disks of this size to a new or existing
page pool

1.8 TB to 3.9 TB

Dual redundancy is recommended when adding disks of this size to a new or existing page pool

4.0 TB or larger

Dual redundancy is required when adding disks of this size to a new or existing page pool

T10-PI Support
Storage Center 7.1 adds support for T10 Protection Information (PI) capable drives.
T10 Protection Information is an end-to-end data integrity feature that protects against silent data corruption.

Volume QoS Profiles
Storage Center 7.1 supports Volume QoS Profiles.
When the Volume QoS Profiles feature is enabled, users can create and manage profiles for Quality of Service (QoS) settings using
Dell Storage Manager 2016 R2.
The volume QoS feature allows users to define an arbitrary quality of service for volumes by setting hard limits on volume IOPS or
throughput. Using the QoS Profiles feature, a user can apply QoS profiles to a single volume or group of volumes.
By default, Dell Storage Manager provides a single default profile which is used for all volumes. Users can create their own custom
profiles and apply them to volumes.

VMware Virtual Volumes Support
Storage Center 7.1 supports VMware Virtual Volumes (VVols) technology.
VMware VVols is a storage management and integration framework designed to deliver a more efficient operational model for
attached storage.
A key component of the VVols framework is the VASA 2.0 Provider included as part of Dell Storage Manager 2016 R2. VASA
(vSphere Storage APIs for Storage Awareness) is a software management interface between the vCenter server and storage
systems. To enable VVols operations between VMware vCenter Server and a Storage Center, the VASA Provider is registered with
VMware vCenter server.
Storage Manager includes these user interface enhancements to support VVols:
•

Addition of the Register VASA Provider option to the Register Server action.

•

New wizards for defining and managing storage containers. A storage container is a pool of storage that is used in a VMware
environment in support of virtual volumes. A storage container corresponds to a VVol datastore in the vCenter interface.

•

A new datastore type, VVOL, can be specified when creating datastores on a VMware vSphere host.

•

Updated storage views to include VVol information.

See the Dell Storage Manager Administrator’s Guide and Dell Storage Manager Release Notes for information about VVols
requirements and recommendations.

Storage Center 7.1 Feature Availability and Licenses
The core licenses and support for optional licensed features varies depending on the storage system.

Dell Storage Center 7.1 Release Notes

5

SC9000 Features and Licenses
SC9000 storage systems provide the following licensed features and optional value-added bundles.

Core Software Bundle
•

Data Instant Replay (Snapshots)

•

Data Reduction (Compression and Deduplication)

•

Dell Storage Manager

•

Dynamic Capacity

•

Dynamic Controllers

•

Live Migrate

•

Local Data Protection

•

Multi-VLAN Tagging

•

Virtual Ports

•

Volume QoS

•

VVols

Optional Licenses
•

Replay Manager

•

Live Volume and Live Volume with Auto Failover

•

Remote Instant Replay (Replication), including Cross-Platform Replication

•

SED FIPS Secure Data

•

Storage Manager Chargeback

Storage Protection Bundle
•

Replay Manager

•

Live Volume and Live Volume with Auto Failover

•

Remote Instant Replay (Replication), including Cross-Platform Replication

Storage Optimization Bundle
•

Data Progression

•

Fast Track

Total Feature Bundle
•

SED FIPS Secure Data

•

Storage Manager Chargeback

•

Storage Optimization Bundle

•

Storage Protection Bundle

SC8000 Features and Licenses
SC8000 storage systems provide the following licensed features:

Core Licenses
•

Data Instant Replay (Snapshots)

•

Data Reduction (Compression and Deduplication)

•

Dell Storage Manager

•

Dynamic Capacity

6

Dell Storage Center 7.1 Release Notes

•

Dynamic Controllers

•

Live Migrate

•

Local Data Protection

•

Multi-VLAN Tagging

•

Volume QoS

•

VVols

Optional Licenses
•

Replay Manager

•

Data Progression

•

Fast Track

•

Live Volume and Live Volume with Auto Failover

•

Remote Instant Replay (Replication), including Cross-Platform Replication

•

SED FIPS Secure Data

•

Storage Manager Chargeback

•

Virtual Ports

SC7020 Features and Licenses
SC7020 storage systems provide the following licensed features and optional value-added bundles.

Core Software Bundle
•

Data Instant Replay (Snapshots)

•

Data Reduction (Compression and Deduplication)

•

Dell Storage Manager

•

Dynamic Capacity

•

Dynamic Controllers

•

Live Migrate

•

Local Data Protection

•

Multi-VLAN Tagging

•

Virtual Ports

•

Volume QoS

•

VVols

Optional Licenses
•

Replay Manager

•

Live Volume and Live Volume with Auto Failover

•

Remote Instant Replay (Replication), including Cross-Platform Replication

•

SED FIPS Secure Data

•

Storage Manager Chargeback

Storage Protection Bundle
•

Replay Manager

•

Live Volume and Live Volume with Auto Failover

•

Remote Instant Replay (Replication), including Cross-Platform Replication

Storage Optimization Bundle
•

Data Progression

Dell Storage Center 7.1 Release Notes

7

•

Fast Track

Total Feature Bundle
•

SED FIPS Secure Data

•

Storage Manager Chargeback

•

Storage Optimization Bundle

•

Storage Protection Bundle

SC4020 Features and Licenses
SC4020 storage systems provide the following licensed features:

Core Licenses
•

Data Instant Replay (Snapshots)

•

Data Reduction (Compression and Deduplication)

•

Dell Storage Manager

•

Dynamic Capacity

•

Dynamic Controllers

•

Live Migrate

•

Local Data Protection

•

Multi-VLAN Tagging

•

Volume QoS

•

VVols

Optional Licenses
•

Replay Manager

•

Data Progression

•

Fast Track

•

Live Volume and Live Volume with Auto Failover

•

Remote Instant Replay (Replication), including Cross-Platform Replication

•

SED FIPS Secure Data

•

Storage Manager Chargeback

•

Virtual Ports

Performance/Optimization Bundle
•

Data Progression

•

Fast Track

Remote Data Protection Bundle
•

Remote Instant Replay (Replication)

Remote Data Protection with Live Volume Bundle
•

Remote Instant Replay (Replication)

•

Live Volume and Live Volume with Auto Failover

8

Dell Storage Center 7.1 Release Notes

SCv2000 Series Features and Licenses
SCv2000 series storage systems provide the following licensed features:

Core Licenses
•

Dell Storage Manager

•

Dynamic Capacity

•

Dynamic Controllers

Optional Licenses
•

Flex Port

•

Local Data Protection (Snapshots)

•

Remote Data Protection (Asynchronous replication only)

Storage Center 7.1 Scalability
The following scalability guidelines apply to Storage Center 7.1.

Storage System Scalability Guidelines
The following scalability guidelines apply to SC9000, SC8000, SC7020, SC4020, and SCv2000 series storage systems.
NOTE: Raw storage space is expressed in decimal units (for example, 1 TB = 1012 bytes). Addressable storage space is
expressed in base 2 units (for example, 1 TB = 240 bytes). Therefore, a 1 TB drive measured in decimal units is equal to
0.909 TB base 2 units.
Storage System

Supported Maximum

SC9000 (Dual-Controller) with 128 GB of
memory per controller

•
•

SC8000 (Dual-Controller) with 64 GB of
memory per controller

•
•

SC8000 (Dual-Controller) with 16 GB of
memory per controller

•
•

SC7020 (Dual-Controller) with 128 GB of
memory per controller

•
•

SC4020 with 16 GB of memory per controller

•
•

SCv2000 series with 8 GB of memory per
controller

•

3.1 PB raw and 2.0 PB addressable storage space using the standard 2 MB
page size
750 TB raw and 500 TB addressable storage space using a 512 KB page size
3.1 PB raw and 2.0 PB addressable storage space using the standard 2 MB
page size
750 TB raw and 500 TB addressable storage space using a 512 KB page size
750 TB raw and 500 TB addressable storage space using the standard 2 MB
page size
400 TB raw and 300 TB addressable storage space using a 512 KB page size
3.1 PB raw and 2.0 PB addressable storage space using the standard 2 MB
page size
750 TB raw and 500 TB addressable storage space using a 512 KB page size
1054 TB raw and 700 TB addressable storage space using the standard 2 MB
page size
500 TB raw and 400 TB addressable storage space using a 512 KB page size
672 TB raw and 450 TB addressable storage space using the standard 2 MB
page size

Dell Storage Center 7.1 Release Notes

9

Storage Center Scalability Guidelines
The following scalability guidelines are the maximum recommended design guidelines for storage systems running Storage Center 7.1.

SC9000, SC8000, SC7020, and SC4020 Storage Systems
The following scalability guidelines are the maximum recommended design guidelines for SC9000, SC8000, SC7020, and SC4020
storage systems running Storage Center 7.1.
Storage Center Object

Supported Maximum

Disk Folder

10 disk folders

Server

•
•
•

500 servers (Total number of servers includes physical servers, virtual servers, and server
clusters.)
500 server folders
1000 server HBA initiator ports (Total number of HBA initiator ports includes all physical and
virtual ports that are visible to the SAN.)

Volume

•
•
•

Deduplication

1 PB data ingestion limit (SC4020 – 500 TB data ingestion limit)

Live Volume

100 Live Volumes

Thin Import

10 volumes (maximum simultaneous imports)

QoS Profiles

•
•
•

100 Volume QoS Profiles
100 Group QoS Profiles
100 Volumes per Group QoS Profile

Data Instant Replay
(Snapshots)

•

Snapshots:

•
•
•
•

– SC9000 – 16,000 snapshots
– SC8000 – 16,000 snapshots
– SC7020 – 16,000 snapshots
– SC4020 – 4000 snapshots
1000 snapshot profiles
100 snapshot history profiles
200 consistency groups
100 volumes per consistency group (SC4020 – 40 volumes per consistency group)

•

Source replications:

•

– SC9000 – 500 source replications
– SC8000 – 500 source replications
– SC7020 – 1000 source replications
– SC4020 – 250 source replications
2000 target replications (SC4020 – 1000 replications for FC and 230 replications for iSCSI)

Replications

500 TB maximum volume size (or the maximum addressable storage space, whichever is less)
2000 volumes
500 volume folders

SCv2000 Series Storage System
The following scalability guidelines are the maximum recommended design guidelines for SCv2000 series storage systems running
Storage Center 7.1.

10

Dell Storage Center 7.1 Release Notes

Storage Center Object

Supported Maximum

Disk Folder

4 disk folders

Server

•
•
•

100 servers (Total number of servers includes physical servers, virtual servers, and server
clusters.)
100 server folders
200 server HBA initiator ports (Total number of HBA initiator ports includes all physical and
virtual ports that are visible to the SAN.)

Volume

•
•
•

Thin Import

10 volumes (maximum simultaneous imports)

QoS Profiles

•
•
•

100 Volume QoS Profiles
100 Group QoS Profiles
100 Volumes per Group QoS Profile

Data Instant Replay
(Snapshots)

•
•
•
•
•

2000 snapshots
1000 snapshot profiles
100 snapshot history profiles
100 consistency groups
25 volumes per consistency group

•
•

124 source replications
500 target replications

NOTE: Data Instant
Replay is a licensed
feature.
Replications

500 TB maximum volume size (or the maximum addressable storage space, whichever is less)
1000 volumes
500 volume folders

Fixed Issues
The following sections summarize the issues fixed in Storage Center 7.1.

Fixed Issues Related to Data Reduction
The following issues are fixed in Storage Center 7.1:
Table 3. Fixed Data Reduction Issues in Storage Center 7.1.20

Issue

Description

SCOS-40135

A storage system with Deduplication enabled might display a false positive metadata validation
failure message in the Storage Center console and generate validation failure alerts in the
Deduplication map table.

SCOS-39128

A storage system with Deduplication enabled might experience increased latency while expiring
deduplicated data or during Data Progression.

SCOS-34642

A controller might reset if too many storage system resources are consumed during Deduplication
and snapshot expiration of deduplicated pages.

SCOS-27942

A storage system with Deduplication enabled might fail to remove page pool devices during a
RAID rebalance because of performance issues.

SCOS-24830

A controller might reset during lost space recovery in the Deduplication page manager.

SCOS-24167

A storage system with Deduplication enabled volumes might experience performance issues
during the Deduplication page manager clean-up process.

Dell Storage Center 7.1 Release Notes

11

Issue

Description

SCOS-22379

The Compression and Deduplication page manager defragmentation process might cause high
CPU utilization and impact system performance.

SCOS-21671

Rehydration of deduplicated or compressed data does not place the data in the tier specified by
the volume storage profile.

SCOS-19002

Enabling deduplication on a storage system while one controller is in a failed state might result in
volumes that appear to be deduplicated, when in fact they are not deduplicated.

Table 4. Fixed Data Reduction Issues in Storage Center 7.1.12

Issue

Description

SCOS-32152

A storage system with Deduplication or Compression enabled that is running low on system
memory might experience I/O errors, performance degradation, and premature Live Volume
failovers.

SCOS-31054

Enabling Deduplication on a volume that is part of a replication might result in hundreds of
Ingestion failure due to SecondaryStorage infrastructure is not
ready log messages.

SCOS-21275

After updating from Storage Center 7.1.1, a storage system might fail to enable Deduplication on
some volumes.

Table 5. Fixed Data Reduction Issues in Storage Center 7.1.3

Issue

Description

SCOS-20960

The IOPS of a storage system might decrease, and I/O latency might increase significantly
because of high CPU usage during the Data Progression defragmentation process.

SCOS-20449

A controller reset might occur because of out of range memory access during the Data
Progression defragmentation process.

SCOS-20240

Data Progression might fail to move pages to tier 3 for volumes that are larger than 32 TB. If a
specific history has multiple view volumes, Data Progression might fail to move pages for volumes
smaller than 32 TB.

SCOS-20075

A storage system with Flash Optimized storage types and Deduplication enabled might suffer an
outage during On Demand Data Progression if the system is low on space in tier 1 RAID 10.

SCOS-19570

A storage system running Storage Center 7.1 with compression enabled and over 25 TB of data
ingested into the Deduplication process might suffer from I/O delays because of high CPU usage
at the end of Data Progression.

Table 6. Fixed Data Reduction Issue in Storage Center 7.1.2

Issue

Description

SCOS-19580

The front-end I/O performance of a storage system might degrade during Data Progression after
a few terabytes of data are ingested into the Deduplication process.

Table 7. Fixed Data Reduction Issues in Storage Center 7.1.1

Issue

Description

SCOS-14931

On Demand Data Progression may not complete successfully when Deduplication is enabled on a
volume.

SCOS-13649

Volumes on separate controllers might show the same Deduplication reduction rates when the
Deduplication reduction rates are different.

12

Dell Storage Center 7.1 Release Notes

Issue

Description

SCOS-13159

Deduplication and Compression might take volumes offline when responses to storage type status
are incorrect.

Fixed Issues Related to Hardware
The following issues are fixed in Storage Center 7.1:
Table 8. Fixed Hardware Issues in Storage Center 7.1.20

Issue

Description

SCOS-41017

An iSCSI I/O card might fail to exit hibernate mode after a reset.

SCOS-40447

On SCv2000 series and SC4020 storage systems, the Eth1 IPC path down might go down due to
system resource issues.

SCOS-40207

On storage systems running Storage Center 7.1.3 or 7.1.4, an iSCSI I/O card might reset because
of an IORP timeout that is 10 seconds greater than the IORP requested timeout.

SCOS-35618

On SCv2000 series and SC4020 storage systems, the battery backup unit (BBU) might fail to
recover from a BMC reset.

Table 9. Fixed Hardware Issues in Storage Center 7.1.12

Issue

Description

SCOS-22733

A Cisco UCS blade server running ESXi might fail to boot from SAN after updating the Storage
Center software on a storage system.

SCOS-22018

Unknown drive vendor I/O errors that are not handled correctly during a Storage Center error
condition might cause an increase in system latency.

SCOS-19991

An SC9000 controller might reset because of issues with the cache card during controller failover.

SCOS-19920

The drive fault LED might remain lit if the ready for removal command is sent after the drive is
removed.

SCOS-15234

A storage controller in an SC4020 storage system might reset if the driver for internal
communication finds a fatal error reported in the register.

SCOS-13232

A Fibre Channel port or controller might reset due to RISC pause errors on a QLogic 8 Gb Fibre
Channel HBA.

Table 10. Fixed Hardware Issues in Storage Center 7.1.1

Issue

Description

SCOS-16637

A 10 Gb iSCSI I/O card is unable to receive data from an Oracle Linux server if the write
command is 8,126,464 bytes or larger.

SCOS-15864

A dual controller reset might occur if a single volume is mapped to more than 10 local ports per
controller.

SCOS-15697

A dual controller reset might occur due to a data overflow issue with a 10 Gb iSCSI I/O card.

SCOS-15264

A dual controller reset might occur following the deletion of iSCSI remote port configurations.

SCOS-15263

The embedded iSCSI ports might reset because of connection timeouts to remote storage
systems.

SCOS-15002

A controller reset might occur because of high memory usage caused by login requests that take
a long to time process during heavy I/O.

Dell Storage Center 7.1 Release Notes

13

Issue

Description

SCOS-14901

An SCv2000 series controller reset might occur due to an issue with the system profile size.

SCOS-14257

A controller reset might occur because of an issue with deduplication.

SCOS-13499

An SC400 expansion enclosure might report incorrect high temperature warnings.

SCOS-13353

SC8000 controllers with CHA3 cache cards might reset due to a reference to a no longer
supported Storage Center subsystem.

SCOS-12881

An SC400 or SC420 expansion enclosure might incorrectly report high temperature warnings.

SCOS-10740

An SCv2000 series storage system might unexpectedly shut down because of a high operating
temperature issue.

SCOS-10012

VMotioning VMs to an SC7020 might cause the datastore to go offline.

SCOS-10010

Auto discovery of an SC7020 might fail in some installation environments.

SCOS-9033

An SCv2000 series or SC4020 storage system running Storage Center 6.5.2 might incorrectly
create swap alerts.

SCOS-7943

A controller might reset if the iSCSI initiator logs out from the target, but the initiator fails to
terminate the connection.

SCOS-6420

An SCv2000 series controller reset might occur due to an incorrect front-end SAS I/O card
critical temperature alert.

SCOS-6338

Storage Center UPS monitoring does not support newer UPS network cards.

SCOS-3400

The embedded iSCSI ports on an SCv2080 series storage system might reset on configurations
where there is congestion at the initiator, causing flow control back to the storage system.

SCOS-2570

On rare occasions, a RAID device might not be degraded properly when a second write failure is
reported for the same device.

SCOS-2548

An SC9000 controller might reset due to an issue during controller failover.

SCOS-2534

After updating to Storage Center 6.6.5 a controller with iSCSI I/O cards might reset during a
front-end rebalance, resulting in an outage.

SCOS-2390

An iSCSI I/O card might send out an Address Resolution Protocol (ARP) request for IP on another
network if it cannot find a gateway.

SCOS-2386

A controller might reset if an iSCSI host sends a non-512 byte aligned first burst size when
Immediate Data is enabled.

SCOS-2098

Performing a non-service affecting upgrade from a CHA3 cache card to a 4 GB Write cache card
might cause the upgrade to fail due to card installation errors.

SCOS-1476

A controller might reset and fail-over might be unsuccessful due to an iSCSI I/O cache card
memory leak with iSCSI attached Oracle and Linux servers.

SCOS-1408

If TCP RX fragmentation is enabled on iSCSI I/O cards, the card might enter and exit hibernation
mode, causing replications to fail.

SCOS-1380

On rare occasions, a single-disk predictive failure might cause high latency because of long disk
recovery during I/O.

SCOS-684

A short duration AC line brownout on an SCv2000 series or SC4020 storage system might cause
unnecessary controller failover.

SCOS-208

Disks might get a BadRegionsPresent health code during a rebuild, even when they are down, due
to the multiple RIPExpired errors.

14

Dell Storage Center 7.1 Release Notes

Issue

Description

SCOS-206

Disks might get excessive health codes because of RIPExpired issues codes on devices that are
down.

Fixed Issues Related to Replication and Live Volume
The following issues are fixed in Storage Center 7.1:
Table 11. Fixed Replication and Live Volume Issues in Storage Center 7.1.20

Issue

Description

SCOS-36665

A controller reset might occur while attempting to fail over a Windows cluster on an RDM volume
mapped to non-unified ESXi hosts when using Live Volume High Consistency.

SCOS-35656

Live Volume proxy disk space might be counted towards the total available system disk space.

SCOS-32134

Access to a volume might be lost if out of memory errors occur before the replication enters the
suspending state.

SCOS-7793

A storage system might fail to delete a replication when the QoS node is blocked and there is
outstanding I/O.

Table 12. Fixed Replication and Live Volume Issues in Storage Center 7.1.12

Issue

Description

SCOS-22156

The VVols feature in ESXi 6.0 Update 2 fails to work properly with Storage Center 7.1.2.

SCOS-21399

A controller might reset during cross-platform replication initialization with a PS Series array.

SCOS-19269

In a two controller storage system, the active controller might reset during failover after
performing a Storage Center update on the peer controller.

SCOS-16677

When creating a Live Volume, choosing a destination volume that is mapped to a server might
cause the Live Volume to go offline. This might cause other volumes that use Deduplication or
Compression on the destination Storage Center to go offline.

SCOS-16377

In rare instances, a storage system with Live Volumes might reset when multiple changes are
made to the Fibre Channel switch configurations within a short time period.

Table 13. Fixed Replication and Live Volume Issues in Storage Center 7.1.1

Issue

Description

SCOS-14576

Unable to perform Storage Center to PS Series group replication if the Storage Center volume
name contains Chinese, German, French, Japanese, or Spanish characters.

SCOS-14065

Thin Import setup is unable to activate the destination volume on a Storage Center when iSCSI is
not configured on the storage system.

SCOS-13152

A cross-platform replication snapshot from a PS Series array to a Storage Center might display
the wrong volume icon.

SCOS-1928

In ESXi 5.5 or later hosts, the status of a secondary Live Volume remains down after bringing the
primary Storage Center back online.

SCOS-706

Converting an existing ESXi datastore volume to Live Volume might cause the volume to
disconnect from the ESXi hosts.

Dell Storage Center 7.1 Release Notes

15

Fixed Issues Related to Alerts and Reporting
The following issues are fixed in Storage Center 7.1:
Table 14. Fixed Alert and Reporting Issues in Storage Center 7.1.20

Issue

Description

SCOS-29664

The storage system might report hundreds of Log Corrupt Page Address error messages during a
RAID restripe.

Table 15. Fixed Alert and Reporting Issues in Storage Center 7.1.12

Issue

Description

SCOS-21331

The Storage Center email process might stop and fail to restart. This issue causes the Storage
Center alert email queue to fill up, which might cause a controller to reset.

Table 16. Fixed Alert and Reporting Issues in Storage Center 7.1.1

Issue

Description

SCOS-12602

On rare occasions, enabling SNMP causes the SNMP agent to stop unexpectedly and it cannot
be restarted.

SCOS-12287

Incorrect SSD endurance tracker alerts might appear if duplicate endurance tracker entries are
created.

SCOS-2906

For SCv2000 series storage systems, the Storage Center does not report if the SAS backend is
disconnected.

SCOS-2492

In Storage Center 6.6, enabling the AUTH LOGIN option in the SMTP Server settings might cause
the email manager to fail.

SCOS-1852

In Storage Center 6.5.10 or later, snapshot messages in system logs might contain an incorrect
Position 3072 is past the expected bound error message.

SCOS-1546

The Storage Center admin user does not receive an email when a disk folder is close to being full.

SCOS-1136

When compression is enabled, volume storage usage statistics are not reported correctly.

SCOS-600

In Storage Center 6.5 and 6.6, the SMTP service might not function properly due to ARP reply
packet rejection.

Fixed Issues Related to Security
The following issues are fixed in Storage Center 7.1:
Table 17. Fixed Security Issues in Storage Center 7.1.20

Issue

Description

SCOS-40490

Updated the OpenSSL version on the Storage Center to OpenSSL 1.0.1u to address the following
security vulnerabilities:
•
•
•
•
•
•
•
•

16

CVE-2016-2177 – www.cvedetails.com/cve/CVE-2016-2177/
CVE-2016-2178 – www.cvedetails.com/cve/CVE-2016-2178/
CVE-2016-2179 – www.cvedetails.com/cve/CVE-2016-2179/
CVE-2016-2180 – www.cvedetails.com/cve/CVE-2016-2180/
CVE-2016-2181 – www.cvedetails.com/cve/CVE-2016-2181/
CVE-2016-2182 – www.cvedetails.com/cve/CVE-2016-2182/
CVE-2016-2183 – www.cvedetails.com/cve/CVE-2016-2183/
CVE-2016-6302 – www.cvedetails.com/cve/CVE-2016-6302/

Dell Storage Center 7.1 Release Notes

Issue

Description
•

SCOS-40083

CVE-2016-6303 – www.cvedetails.com/cve/CVE-2016-6303/

Clickjacking vulnerability found on web server ports in Storage Center.

Table 18. Fixed Security Issues

Issue

Description

SCOS-10577

Security enhancement regarding the following vulnerabilities:
•
•

CVE-2012-4930 – www.cvedetails.com/cve/CVE-2012-4930/
CVE-2012-4929 – www.cvedetails.com/cve/CVE-2012-4929/

SCOS-7936

Security enhancement regarding Apache HTTPD and OpenSSL vulnerabilities.

SCOS-3356

Security enhancement regarding the following vulnerability:
CVE-2015-1283 – www.cvedetails.com/cve/CVE-2015-1283/

SCOS-3254

A controller reset may occur due to a TCP connection LAST_ACK socket state error.

Fixed Issues Related to Storage Management
The following storage management issues are fixed in Storage Center 7.1:
Table 19. Fixed Storage Management Issues in Storage Center 7.1.20

Issue

Description

SCOS-40999

Metadata on inconsistent RAID mirrors/stripes might cause Data Progression failures and lead to
inefficient system space usage and performance degradation.

SCOS-40725

A controller might reset when updating statistics for page moves between classes if the source
page is on a device marked for deletion.

SCOS-40529

A controller reset might occur if there are a large number of metadata space allocation requests at
the same time for a volume.

SCOS-40491

SNMP management queries might fail to function properly on storage systems running Storage
Center 7.1.

SCOS-37561

A controller might reset unexpectedly under certain rare timing conditions.

SCOS-40094

Storage Center might delay Data Progression/restripe activity to unacceptable levels if there are
other higher priority background processes.

SCOS-37719

A controller might reset after updating to Storage Center 7.1.3, 7.1.4, or 7.1.5. because of an issue
with memory fragmentation.

SCOS-36475

A storage system might encounter high CPU usage during page validation stage of Data
Progression. This issue is limited to pages consumed from the storage type.

SCOS-36534

Storage Center is unable to create more than a single spare drive on an SC280 enclosure if an
SC220 and SC280 were connected to the storage system during the initial system configuration.

SCOS-36336

A controller might reset when the lock associated with a particular message type cannot be
found. Due to variable timing conditions within the platform, messages can arrive out of order.

SCOS-36319

On storage systems that only have spinning disks and have large volumes with a large number of
new page writes, existing snapshots take a very long to expire.

SCOS-35648

Removing a port from a fault domain while a controller is down might result in storage system
configuration issues.

Dell Storage Center 7.1 Release Notes

17

Issue

Description

SCOS-32925

On rare occasions, a storage system might experience performance degradations due to a
mismatch in a virtualization threshold value.

SCOS-31707

Importing multiple volumes from an external device using Thin Import causes the volumes to
appear as external devices with the following error:
illegal character found for Attribute: Name
[Illegal Chracters: [<, >, &] ]]

Table 20. Fixed Storage Management Issues in Storage Center 7.1.12

Issue

Description

SCOS-40856

A controller might reset if the iSCSI initiator is redirected to an IPv4 address of 0.0.0.0.

SCOS-40529

A storage controller might reset because of resource depletion issues on large control space
allocations.

SCOS-36717

On an SC4020 storage system, Data Progression might fail because of memory allocation issues.

SCOS-34081

Data Progression might not complete because of a missing Compression freelist entry.

SCOS-32882

A storage controller in an SC4020 storage system might reset because of memory allocation
issues for unaligned RAID 10 I/Os.

SCOS-26905

A storage system that performs Deduplication might send SupportAssist information to Dell
Technical Support that cannot be properly processed.

SCOS-26753

A replacement drive might fail to initialize because of depleted Storage Center software
resources.

SCOS-24830

A storage controller might reset while Data Progression performs a clean-up action on
compressed data.

SCOS-21900

Updating to Storage Center 6.7.5 might cause an increase in BadRegionsPresent health code
errors for drives.

SCOS-20142

A controller might reset when the settings of a new Fault Domain are modified.

SCOS-19766

A storage system might enter emergency mode if it is unable to create page pool devices due to
CA out of space errors.

SCOS-18185

A controller might reset when removing an enclosure or reinserting a previously archived or
deleted disk into the enclosure from which it was removed.

SCOS-16637

A storage system with Chelsio 10 Gb iSCSI HBAs might be unable to handle large I/O sizes.

Table 21. Fixed Storage Management Issues in Storage Center 7.1.4

Issue

Description

SCOS-22591

The defragmentation attributes have been modified to reduce CPU usage that could impact
server I/O latency.

Table 22. Fixed Storage Management Issues in Storage Center 7.1.3

Issue

Description

SCOS-21562

In Storage Center 7.1, manual and scheduled restripes are restricted to 12 hours per day.

SCOS-18899

A storage system might incorrectly report snapshot bad pages when the system is low on
memory.

18

Dell Storage Center 7.1 Release Notes

Issue

Description

SCOS-20668

An SCv2000 series or SC4020 storage system might trigger alerts or reset because of high
memory utilization caused by memory fragmentation.

SCOS-18540

A controller revert might take several minutes to complete while deactivating the history of a large
volume (several TBs) if the storage system has space management snapshots.

Table 23. Fixed Storage Management Issue in Storage Center 7.1.2

Issue

Description

SCOS-18932

Using Offloaded Data Transfer (ODX) in Hyper-V might result in degraded MPIO paths.

Table 24. Fixed Storage Management Issues in Storage Center 7.1.1

Issue

Description

SCOS-17884

When deduplication is enabled, Data Progression may not complete successfully due to memory
allocation recovery issues.

SCOS-16576

On rare occasions during a RAID rebalance, a short timing window may occur where inaccurate
pagepool information is read from the system resulting in volumes becoming inaccessible for a
brief period.

SCOS-15831

A controller reset might occur while modifying or deleting an iSCSI fault domain.

SCOS-15651

Data Progression failures might occur if Data Progression is running on a volume with snapshots
that expire at the same time.

SCOS-15239

After updating to Storage Center 7.0, Data Progression times might increase when compression or
deduplication is enabled.

SCOS-14111

Secondary storage deactivation process is not flushing prefetch pages.

SCOS-13724

A single controller storage system shows servers as partially connected when servers are
connected using Fibre Channel.

SCOS-10256

Creation of the first volume on a storage system with 7K drives might result in a false PagePool
7K Down alert condition.

SCOS-9946

Data optimization statistics might fail to update after a snapshot coalescence.

SCOS-8853

Data Progression might fail to start after updating a storage system to Storage Center 6.7.

SCOS-8742

Performing a thin import to a destination volume with compression enabled causes all volumes on
the storage system with compression enabled to transition to a down state.

SCOS-8543

When the compression feature is enabled for a volume, the volume might become inaccessible.

SCOS-8248

In a Windows 2012 R2 virtual machine running in ESXi 5.5 or Hyper-V on Windows Server 2012,
an iSCSI Offloaded Data Transfer (ODX) attempt is causing volume access to hang when the
volumes are on different storage systems.

SCOS-7932

Adding a storage system to Dell Storage Manager might fail if the storage system is licensed for
SEDs, but it does not have any SED disks.

SCOS-7533

On a storage system with compression enabled, performance degradation might occur during the
first few minutes of Data Progression because of table validation.

SCOS-7269

In Storage Center 6.7.5, setting the VLAN Priority to a value above 0 on a fault domain with an
iSCSI I/O card that is doing VLAN tagging might prevent iSCSI initiators from logging in.

SCOS-6821

After performing an import from a PS Series storage array, Storage Center continues to attempt
to log in to the PS Series storage array, which causes multiple failure logs.

Dell Storage Center 7.1 Release Notes

19

Issue

Description

SCOS-3276

Web services under a sustained heavy workload might fail to restart resulting in a loss of access
to the Storage Center management interface.

SCOS-2410

On rare occasions, snapshots might fail to expire in Storage Center 6.5.20.

SCOS-1920

Directly connecting to an SCv2000 series storage system with the Dell Storage Client and
modifying Storage Center user preferences might result in an error.

SCOS-1200

Command timeouts and errors might occur after installing FIPS WI-SSDs on a storage system
running Storage Center 6.6.5.

SCOS-928

Storage systems might report increased memory usage due to improper release of sockets.

SCOS-104

A volume restripe operation with large amounts of compressed data might take an extended
amount of time to restripe due to Data Progression errors.

SCOS-100

On rare occasions, Data Progression and subsequent rebalancing might fail due to snapshot full
page memory limitations.

Fixed Issues Related to Updating, SupportAssist, and Licensing
The following issues are fixed in Storage Center 7.1:
Table 25. Fixed Updating, SupportAssist, and Licensing Issues in Storage Center 7.1.20

Issue

Description

SCOS-40141

After updating a storage system to Storage Center 7.1.4, controllers might reset while processing
the Link Configuration initialization step.

SCOS-35674

An SC4020 storage system might suffer an outage after updating from Storage Center 6.7 to 7.1 if
the storage system exceeds the maximum number of snapshots.

Table 26. Fixed Updating, SupportAssist, and Licensing Issues in Storage Center 7.1.12

Issue

Description

SCOS-24853

In a dual-controller storage system, a license file conflict might cause the controllers to reboot.

SCOS-21811

A controller might fail to boot if the Disk Folder is deleted after updating to Storage Center 7.1.

SCOS-20769

If there is an existing invalid trap on the Storage Center, a storage controller might fail to boot
after updating to Storage Center 7.1.2 because of the changes made to support SNMPv3.

Table 27. Fixed Updating, SupportAssist, and Licensing Issues in Storage Center 7.1.3

Issue

Description

SCOS-20301

The disk initialization feature is not fully enabled on storage systems that are updated to Storage
Center 7.1.

Table 28. Fixed Updating, SupportAssist, and Licensing Issues in Storage Center 7.1.2

Issue

Description

SCOS-18287

Firmware updates might fail when updating an SCv2000 series storage system or an SC4020
storage system from Storage Center 6.6 to Storage Center 7.1.

20

Dell Storage Center 7.1 Release Notes

Table 29. Fixed Updating, SupportAssist, and Licensing Issues in Storage Center 7.1.1

Issue

Description

SCOS-3438

After updating an SCv2000 series or SC4020 storage system to Storage Center 6.6, performing
an update to Storage Center 6.7 might cause performance issues due to improperly handled
update file links.

SCOS-3370

Sending diagnostic data using SupportAssist might fail after updating from Storage Center 6.4 or
6.5 to Storage Center 6.6 and later due to previous, pending requests that are unable to complete.

SCOS-2938

Applying the incorrect version of a license file to an SC4020 storage system might cause issues
with the Flex Port feature and management of legacy disks.

SCOS-1868

For SC4020 storage systems, an enclosure firmware update might fail due to missing
electronically stored information (ESI) paths during installation.

SCOS-694

On rare occasions, when performing a non-service affecting update, a controller may reset due to
duplicate and/or overlapping data writes.

Fixed Issues Related to User Management
The following issues are fixed in Storage Center 7.1:
Table 30. Fixed User Management Issues

Issue

Description

SCOS-14309

Storage Center does not restrict directory service communication to manually defined LDAP
servers. This issue might cause delays when joining Storage Center to a directory environment or
failures when adding directory users and groups to Storage Center for authentication.

SCOS-13835

The password of the Baseboard Management Controller (BMC) resets to the default value after a
controller reset.

SCOS-13236

An error might occur in the Dell Storage Manager Client if the user preferences snapshot profile
list is invalid.

Open Issues
The following issues are present in Storage Center 7.1.

Open Issues Related to Data Reduction
The following open issues are related to Data Reduction:
Table 31. Open Data Reduction Issues

Issue

Description

SCOS-13237

The Storage Type Data Reduction statistics might be incorrect if the amount of data eligible for
Data Reduction contains fewer than 256 pages.
Workaround: None

Dell Storage Center 7.1 Release Notes

21

Open Issues Related to Hardware
The following open issues are related to hardware:
Table 32. Open Hardware Issues

Issue

Description

SCOS-18759

The QLe246x Fibre Channel I/O Card takes longer to rebalance in Storage Center 7.1 than it did in
previous versions of Storage Center.
Workaround: The QLe246x I/O card is not supported in Storage Center 7.1 and must be replaced
with a supported Fibre Channel I/O card.

SCOS-18490

When connected directly to the Storage Center using the Dell Storage Manager Client, an error
occurs in the hardware change wizard while performing a hardware migration from an SC040
running Storage Center 6.7 to an SC8000 running Storage Center 7.1.
Workaround: Connect to the Storage Manager Data Collector using the Dell Storage Manager
Client and then run the hardware change wizard on the Storage Center.

SCOS-10427

On rare occasions, an SCv2000 series or SC4020 storage system may not initialize following a
reset or power cycle.
Workaround: Reboot the storage system by performing a power cycle on the controllers. After
the controllers are power cycled, the storage system boots up successfully.

SCOS-6516

On rare occasions, the internal boot device on an SC9000 controller may become unusable
following an unexpected power event and the controller will not boot.
Workaround: Contact Dell Technical Support.

Open Issues Related to Replications and Live Volumes
The following open issues are related to replications and Live Volumes:
Table 33. Open Replication and Live Volume Issues

Issue

Description

SCOS-18102

The status of a cross-platform replication partner changes to down when the number of
snapshots exceed 1025.
Workaround: The maximum number of supported snapshots for a cross-platform replication is
512. To resolve this issue, manually remove the snapshots until there are less than 512 snapshots
and change the expiration dates of snapshots for the replication volume to a manageable
expiration time.

SCOS-17981

Server mappings may not be completely removed when a server is removed from an OS cluster
using Dell Storage Manager prior to the server being removed from the OS cluster.
Workaround: Remove the server from the cluster through the OS first. After the server is
rebooted, remove the server object using Dell Storage Manager.

SCOS-12067

When importing a volume, Storage Manager does not allow you to select 0 as the LUN number.
Workaround: None

22

Dell Storage Center 7.1 Release Notes

Open Issues Related to Storage Management
The following open issues are related to Storage Management:
Table 34. Open Storage Management Issues

Issue

Description

SCOS-14951

After deleting volumes and snapshots, Storage Center does not immediately report the deleted
volume space as free space for a disk folder.
Workaround: Contact Dell Technical Support.

Open Issues Related to Updating, SupportAssist, and Licensing
The following open issues are related to updating , SupportAssist, and licensing:
Table 35. Open Updating, SupportAssist, and Licensing Issues

Issue

Description

SCOS-18488

The Storage Center System Manager user interface is not disabled after updating a dualcontroller storage system from Storage Center 6.6.5 to Storage Center 7.1.1.
Workaround: Reboot the storage system.

Open Issues Related to User Management
The following open issues are related to Storage Center user management:
Table 36. Open User Management Issues

Issue

Description

SCOS-11192

Storage Center cannot authenticate directory service users that are configured to use an
alternate DNS suffix.
Workaround: None

Open Issues Related to Vendors
The following open issues are related to vendors:
Table 37. Open Vendor Issues

Issue

Description

SCOS-18203

In certain degraded conditions, data miscompares might occur when running software FCoE on
an Intel X520 adapter in an ESXi 5.5 or 6.0 host.
Workaround: Issue has been escalated with VMware. See the Dell Storage Compatibility Matrix
for updates.

SCOS-18123

Fibre Channel volumes that are mapped to a Hyper-V virtual machine using NPIV are not
discovered by the virtual machine when the server has a QLogic HBA with out-of-date drivers.
Workaround: Update the HBA to the latest version of the QLogic driver listed in the Dell Storage
Compatibility Matrix.

SCOS-17996

An ESXi 5.5 or 6.0 host with an Emulex FC/FCoE HBA running driver version 11.0.x.x might crash
during a controller failover.
Workaround: Update the Emulex FC/FCoE HBA to driver version 11.1.145.18, which is available on
the VMware website.

Dell Storage Center 7.1 Release Notes

23

Issue

Description

SCOS-16820

Software FCoE timeouts might occur when using QLogic CNAs in NIC mode.
Workaround: See the Dell Storage Compatibility Matrix for the list of supported firmware and
drivers.

SCOS-10166

Emulex FC and FCoE driver version 10.7.170.0 might cause an ESXi 5.5 or 6.0 host to fail during
controller failovers.
Workaround: Use the latest recommended driver version for the Emulex adapters. See the Dell
Storage Compatibility Matrix.

SCOS-10155

Data Center Bridging bandwidth utilization of traffic classes might cause I/O to stop on iSCSI
initiators when using an Intel X520 Dual Port 10 Gb server adapter.
Workaround: None.

CQ00358236

ESXi 5.x hosts with QxE82xx iSCSI adapters using QLA4xxx driver version 634.5.18 (ESXi 5.1) or
6.34.55.20 (ESXi 5.5) might fail to log in to the Storage Center after a controller reset or failover.
Workaround: Use the latest recommended driver version for the QLogic adapters. See the Dell
Storage Compatibility Matrix.

CQ00252780

On a storage system with iSCSI front-end ports, if a controller or port is in a failover process
when a Windows boot from SAN is requested, the boot might fail.
Workaround: Subsequent boot from SAN requests succeed when the controller or port is up.

Storage Center Update Information
The following information must be considered before updating to Storage Center 7.1.
A storage system must be running Storage Center 6.6.4 or later to perform a SupportAssist update to Storage Center 7.1. For more
information, see the Dell Storage Center Software Update Guide.
NOTE: When performing an update of both Storage Center and Dell Storage Manager, update Dell Storage Manager
before updating Storage Center.

Support Resources
The following section provides resources for finding more information on using a Storage Center storage system.

Related Documentation
The following documents are available for a storage system running Storage Center 7.1.
•

Dell Storage Center Software Update Guide
Describes how to update Storage Center software from an earlier version to the current version.

•

Dell Storage Center Update Utility Administrator’s Guide
Describes how to use the Storage Center Update Utility to install Storage Center software updates. Updating Storage Center
software using the Storage Center Update Utility is intended for use only by sites that cannot update Storage Center using
standard methods.

•

Dell Storage Manager Installation Guide
Provides installation and setup instructions.

•

Dell Storage Manager Administrator’s Guide
Provides instructions for using the Data Collector Manager and the Dell Storage Manager Client.

•

24

Dell Storage Manager Online Help

Dell Storage Center 7.1 Release Notes

Provides context-sensitive help for the Dell Storage Manager Client, Data Collector Manager, and Storage Manager Server
Agent.
•

Dell Storage Manager Release Notes
Provides information about Dell Storage Manager releases, including new features, enhancements, fixed issues, and open issues.

•

Dell Storage REST API Release Notes
Provides information about the Dell Storage REST API, which allows you to manage the Storage Manager Data Collector and
Storage Centers.

Finding Documentation
The following locations contain documentation for a storage system running Storage Center 7.1.
•

Dell Support
Provides documentation for Dell storage products. Go to www.dell.com/support.

•

Dell TechCenter
Provides technical white papers, best practice guides, and frequently asked questions about Dell storage products. Go to http://
en.community.dell.com/techcenter/storage/.

Contacting Dell
Dell provides several online and telephone-based support and service options. Availability varies by country and product, and some
services might not be available in your area.
To contact Dell for sales, technical support, or customer service issues, go to www.dell.com/support.
•

For customized support, type your system service tag on the support page and click Submit.

•

For general support, browse the product list on the support page and select your product.

Copyright © 2017 Dell Inc. or its subsidiaries. All rights reserved. Dell, EMC, and other trademarks are trademarks of Dell Inc. or its
subsidiaries. Other trademarks may be trademarks of their respective owners.
Dell Storage Center 7.1 Release Notes

25



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Author                          : Dell
Create Date                     : 2017:07:20 16:23:53+00:00
Modify Date                     : 2017:07:20 16:23:53+00:00
Creator                         : AH XSL Formatter V6.3 MR3 for Windows (x64) : 6.3.4.25128 (2016/07/01 17:39JST)
Producer                        : Antenna House PDF Output Library 6.3.815 (Windows (x64))
Keywords                        : manual, guide, documentation
Title                           : Dell Storage Center 7.1 Release Notes
Subject                         : release notes
Trapped                         : False
Page Count                      : 25
Page Mode                       : UseOutlines
Tagged PDF                      : Yes
Language                        : EN
EXIF Metadata provided by EXIF.tools

Navigation menu