Dell Storage Scv3000 And SCv3020 System Getting Started Guide User Manual Setup En Us

User Manual: Dell storage-scv3000 - Dell SCv3000 and SCv3020 Storage System Getting Started Guide

Open the PDF directly: View PDF PDF.
Page Count: 10

Dell SCv3000 and SCv3020 Storage System
Getting Started Guide
Regulatory Model: E03T
Regulatory Type: E03T001
Notes, Cautions, and Warnings
NOTE: A NOTE indicates important information that helps you make better use of your product.
CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the
problem.
WARNING: A WARNING indicates a potential for property damage, personal injury, or death.
Copyright © 2017 Dell Inc. or its subsidiaries. All rights reserved. Dell, EMC, and other trademarks are trademarks of Dell Inc. or its
subsidiaries. Other trademarks may be trademarks of their respective owners.
2017 - 8
Rev. A00
Setting Up the Storage System
Consider the following best practices when setting up an SCv3000/SCv3020 storage system.
Dell recommends that you use a dedicated SAN network for data transmission when using a Fibre Channel or iSCSI storage
system.
Always congure redundant data paths to provide alternate paths to and from the host server should one of the data paths
become disabled.
Before connecting any cables between the storage system and host server or expansion enclosure, physically label each port and
connector.
Always follow proper power-up and power-down procedures when cycling power across the network. Verify that critical network
components are on separate power circuits.
NOTE: This product is intended for restricted access locations, such as a dedicated equipment room or equipment closet.
WARNING: If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack
environment may be greater than room ambient temperature. Therefore, consideration should be given to installing the
equipment in an environment compatible with the maximum ambient temperature (Tma) specied by the manufacturer.
Safety Warnings
Two person lift required
A fully congured SCv3000/SCv3020 storage system weighs approximately 43 kg
(95 lb). Use appropriate lifting methods when installing the storage system.
Laser Radiation for Fibre Channel Storage Systems
CAUTION: Class I laser radiation when open, avoid exposure to beam.
WARNING: Laser radiation, avoid direct exposure to beam.
The unit is certied in the U.S. to conform to the requirements of DHHS 21 CFR, chapter 1 Subchapter J for Class I (1) laser
products, and elsewhere is certied as a Class I laser product conforming to the requirements of IEC 60825-1:2007.
Class I laser products are not considered to be hazardous. The laser system and unit are designed so there is never any human
access to laser radiation above a Class I level during normal operation, user maintenance or prescribed service condition.
Locating Your Service Tag
Your storage system is identied by a unique service tag and Express Service Code.
The service tag and Express Service Code are found on the front of the system by pulling out the information tag. Alternatively, the
information might be on a sticker on the back of the storage system chassis. This information is used by Dell to route support calls to
the appropriate personnel.
NOTE: The Quick Resource Locator (QRL) code on the information tag is unique to your system. Scan the QRL to get
immediate access to your system information using your smart phone or tablet.
3
Other Information You May Need
To install the storage system, you may need the following additional information.
NOTE: See the safety and regulatory information that shipped with your Storage Center components. Warranty
information is included as a separate document.
The Dell SCv3000/SCv3020 Storage System Deployment Guide provides information about cabling storage system hardware
components and conguring a new storage system using the Dell Storage Manager Client.
The Dell Storage Manager Administrator’s Guide describes how to use Dell Storage Manager to manage Storage Center
systems.
Installation and Conguration
Before you begin installation, make sure that the site where you plan to install the storage system has standard power from an
independent source or a rack power distribution unit with a UPS.
In addition, verify that there is a 3U space in the lower 20U of the rack to install the storage system. If you plan to install the storage
system above the lower 20U of a rack, a customer-provided mechanical lift must be used to avoid injury.
Unpacking Storage Center Equipment
Unpack the storage system and identify the items in your shipment.
Figure 1. SCv3000/SCv3020 Storage System Components
1. Documentation 2. Storage system
3. Rack rails 4. USB cables (2)
5. Power cables (2) 6. Front bezel
Install the Storage System in a Rack
Install the storage system and other Storage Center system components in a rack.
About this task
Mount the storage system and expansion enclosures in a manner that allows for expansion in the rack and prevents the rack from
becoming topheavy.
4
The SCv3000/SCv3020 storage system ships with a ReadyRails II kit. The rails come in two dierent styles: tool-less and tooled.
Follow the detailed installation instructions located in the rail kit box for your particular style of rails.
NOTE: Dell recommends using two people to install the rails, one at the front of the rack and one at the back.
Steps
1. Position the left and right rail end pieces labeled FRONT facing inward.
2. Align each end piece with the top and bottom holes of the appropriate U space.
Figure 2. Attach the Rails to the Rack
3. Engage the back end of the rail until it fully seats and the latch locks into place.
4. Engage the front end of the rail until it fully seats and the latch locks into place.
5. Align the system with the rails and slide the storage system into the rack.
Figure 3. Slide the Storage System Onto the Rails
6. Lift the latches on each side of the front panel and tighten the screws to the rack.
5
Figure 4. Tighten the Screws
If the Storage Center system includes expansion enclosures, mount the expansion enclosures in the rack. See the instructions
included with the expansion enclosure for detailed steps.
Install the Front Bezel
Install the bezel on the front of the storage system.
1. Hook the right end of the bezel onto the storage system.
Figure 5. Front Bezel
2. Insert the left end of the bezel into the securing slot until the release latch snaps into place.
3. Secure the bezel with the keylock.
6
Connect the Power Cables
Connect power cables to the storage system.
1. Make sure that the power switches are in the OFF position before connecting the power cables.
2. Connect the power cables securely to both power supply/cooling fan modules in the storage system chassis.
Figure 6. Connect the Power Cables
3. Use the straps to secure the power cables to the storage system chassis.
Figure 7. Secure the Power Cables
4. Plug the other end of the power cables into a grounded electrical outlet or a separate power source such as an uninterrupted
power supply (UPS) or a power distribution unit (PDU).
NOM Information (Mexico Only)
The following information is provided on the device described in this document in compliance with the requirements of the ocial
Mexican standards (NOM):
Importer Dell Inc. de México, S.A. de C.V
Paseo de la Reforma 2620-11 ° Piso
Col. Lomas Atlas
11950 México, D.F.
Model number E03T
Supply voltage 100–240 VAC (1378 W)
7
200–240 VAC (1485 W)
Frequency 50/60 Hz
Current consumption 16A-8.25A (1378 W)
8.8 A (1485 W)
Technical Specications
The technical specications of the SCv3000/SCv3020 storage systems are displayed in the following tables.
Drives
SAS hard drives SCv3000 Up to 16 3.5-in. hot-swappable hard drives (12 Gb SAS)
SCv3020 Up to 30 2.5-in. SAS hot-swappable hard drives (12 Gb SAS)
Storage Controllers
Storage controllers Up to two hot-swappable storage controllers with one I/O card slot and one
optional mezzanine card per storage controller.
Each storage controller has an internal battery backup unit. Write cache is
mirrored between the two storage controllers. If a power failure occurs, the
battery backup unit provides power to the storage controller so that the write
cache can be saved to an SSD within the storage controller.
Storage Connectivity
Congurations SCv3000 Supports a total of 150 drives and up to 120 drives on a single SAS
chain.
SCv3020 Supports a total of 150 drives and up to 134 drives on a single SAS
chain.
Redundant Array of Independent Disks (RAID)
Controller Two hot-swappable storage controllers
Management RAID management using the Dell Storage Manager Client
Back-Panel Ports Connectors (per Storage Controller)
Fibre Channel, iSCSI, or SAS front-end
connectors
Connection to a Fiber Channel fabric, iSCSI network, or a direct connection to
servers with SAS HBAs
Ethernet connectors MGMT – 1 Gbps embedded Ethernet port used for Storage Center management
SAS back-end connectors 12 Gb SAS ports for connections to expansion enclosures
NOTE: SAS connectors are SFF-8644 compliant.
Serial connector (micro USB) Used for initial conguration and support-only functions
LED Indicators
Front panel One dual-color LED indicator for system status
One single-color LED indicator for power status
8
LED Indicators
Identication button with a single-color LED
Hard drive carrier One single-color activity LED
One dual-color LED status indicator per drive
Storage controller Two single-color LEDs per Ethernet port indicating activity and link speed
One dual-color LED per SAS connector indicating port activity and status
One single-color LED indicating status
One single-color LED indicating system faults
One single-color LED for system identication
Power supply/cooling fan One dual-color LED handle indicating power supply and cooling fan status
Power Supply Units (PSU)
AC power supply (per power
supply)
PSU Type 1 PSU Type 2 (Japan Only) PSU Type 3
Maximum output power 1485 W 1485 W 1378 W
Maximum input power 1688 W 1707 W 1584 W
Maximum input current 8.8 A 17.5 A 16 A
Maximum inrush current 55 A for 10 ms or less 55 A for 10 ms or less 55 A for 10 ms or less
Nominal input voltage operating
range
200–240 VAC 100–240 VAC 100–240 VAC
Nominal input frequency 50/60 Hz 50/60 Hz 50/60 Hz
Thermal output/heat dissipation 693 BTU per hour 757 BTU per hour 703 BTU per hour
Available Hard Drive Power (Per Slot)
Supported hard drive power consumption
(continuous)
Up to 1.2 A at +5 V
Up to 0.5 A at +12 V
Physical
Height 13.34 cm (5.25 in.)
Width 44.50 cm (17.5 in.)
Depth SCv3000 81.91 cm (32.25 in.)
SCv3020 78.27 cm (31 in.)
Approximate weight (maximum conguration) SCv3000 45 kg
SCv3020 43 kg
Approximate weight without drives 32.5 kg (72 lb)
9
Environmental
For additional information about environmental measurements for specic storage system congurations, see dell.com/
environmental_datasheets.
Temperature
Operating 10°C (50°F) to 35°C (95°F) with a maximum temperature gradation of 20°C/
hour (36°F/hour)
Operating above 35°C could result in data loss
Storage –40° to 65°C (40° to 149°F) at a maximum altitude of 12,000 m (39,370 ft)
Relative humidity
Operating 10% to 80% (noncondensing) with 29°C (84.2°F) maximum dew point
Storage 5% to 95% (noncondensing) with 33°C (91°F) maximum dew point
Maximum vibration
Operating 0.21 G at 5–500 Hz for 15 min
Storage 1.04 G at 2200 Hz for 15 min
Maximum shock
Operating 31 G +/- 5% with pulse duration of 2.6 ms +/- 10% (equivalent to 20 in./sec [51
cm/sec])
Storage 71 G +/- 5% with pulse duration of 2 ms +/- 10% (equivalent to 35 in./sec [89
cm/sec])
Altitude
Operating 3,048 m (10,000 ft)
≤35°C (95°F) Maximum Rating – Maximum temperature is reduced by
1°C/300 m (1°F/547 ft) above 950 m (3,117 ft)
Storage 12,000 m (39,370 ft)
Airborne Contaminant Level
Class G1 or lower as dened by ISA-S71.04-1985
10

Navigation menu