TPM rmware version 1.2 to version 2.0 upgrade
instructions for Wyse 7040 thin client
New releases are created to support new hardware platforms, correct defects, make enhancements, or add new features. These releases
are tested and supported on current, actively shipping hardware platforms, and those hardware platforms that are within their rst year
after their ocial End-of-Life date, as applicable. After the one year time period, new software releases are no longer certied for use with
the earlier version of the hardware, even though it is possible that they may still work. This allows us to advance our product with features
and functions that might not have been supported by the previous hardware, with previous generation CPUs and supporting components.
Contents
Purpose/Background......................................................................................................................................................... 1
Pre-requisites ..................................................................................................................................................................... 1
Supported platforms...........................................................................................................................................................1
Requirements.......................................................................................................................................................................1
Upgrade instructions..........................................................................................................................................................2
TPM update procedure using DOS environment........................................................................................................... 3
Purpose/Background
Change or upgrade from an existing operating system to a newer operating system requires an update to Trusted Platform Module (TPM).
NOTE: For more information about Trusted Platform Technology, go to Dell TechCenter Client TPM WIKI.
Pre-requisites
TPM upgrade is required for select Dell systems, if the operating system that runs on the system is upgraded to Windows 10 IoT Enterprise.
• Windows Embedded Standard 7P systems require TPM rmware version 1.2
• Windows 10 Enterprise systems can use either TPM rmware version 1.2 or 2.0
Supported platforms
Wyse 7040 thin client supports TPM upgrade.
Requirements
NOTE: While performing TPM upgrade, make sure that you do not turn o the power and then turn on again. Any power
disruption that occurs may damage the TPM module during upgrade. If disruption occurs, then the data in hard drive cannot be
accessible and system is not usable.
Systems that shipped with Windows Embedded standard 7P OS from the factory has TPM rmware 1.2. Such systems require Dell TPM
2.0 Update Utility to upgrade the TPM rmware version to version 2.0.
2017 - 01
TPM rmware version 1.2 to version 2.0 upgrade instructions for Wyse 7040 thin client 1

For more information about upgrade instructions for the update utility, see the Upgrade instructions section.
Upgrade instructions
Use the Dell TPM Update Utility for Windows/ DOS to perform the TPM upgrade.
To update the TPM rmware version 1.2 to version 2.0, do the following:
1 Go to Dell TPM 2.0 Update Utility, and download the TPM upgrade utility application le.
2 When the File Download window is displayed, click Save to save the le to your USB mass storage device.
3 Disable Unied Write Filter (UWF) on your thin client. To disable UWF, do the following:
a Log in as an Admin. If logged in as a User, log o and log in to the system again with the Admin credentials.
b On the desktop, double-click the Dell Wyse WF Disable icon.
Write lter is disabled and system reboots.
c After reboot, log o and log in to the Admin account again because auto logon is enabled and the system automatically logs in to
User mode.
d Double-click Dell Thin Client Application, navigate to Auto logon, and then change the default auto logon user name to Admin
from User. Admin or User account referred in this scenario is the local Admin/ User account.
4 Clear the TPM owner before running the TPM update utility. To clear the TPM, do the following:
a If BitLocker is enabled on your system, then suspend the BitLocker encryption before updating the TPM on a BitLocker enabled
system.
b The TPM must be on and enabled in BIOS setup. Ensure that the TPM is not owned. If the TPM is owned, go to BIOS setup and
clear the TPM before proceeding. Run TPM.msc, if applicable, to reinitialize the TPM under Windows OS.
c When the TPM ownership is cleared, some operating systems automatically take ownership of the TPM in the successive boot
(TPM Auto Provisioning), disable this feature in the OS to proceed with the update
5 To disable the TPM Auto Provisioning in Windows, do the following:
a Boot to Windows OS.
b Launch the PowerShell Command window in Admin mode.
c At the PowerShell command prompt, run the following command:
Disable-TpmAutoProvisioning
dConrm the following:
AutoProvisioning: Disabled
System reboot is required.
e Press the F2 Key when rebooting the system to access the BIOS setup.
f Go to Security > TPM 1.2 Security.
g To clear the TPM settings, click the Clear check box and select Yes at the prompt. Skip this step, if the item is disabled.
h To save changes, click Exit.
i Reboot system to Windows.
j Make sure the TPM is not owned. Windows should not provision TPM anymore.
k Browse to the location where you have downloaded the le, and then double-click the new le.
Windows system automatically restarts and update the TPM during the system startup. When the TPM update is complete, the
system auto reboots to take eect.
l To re-enable the auto provisioning, launch the PowerShell command window in Admin mode, and run the following command:
Enable-TpmAutoProvisioning.
mConrm the following:
AutoProvisioning: Enabled
6 After the TPM update is complete, re-enable the Unied Write Filter (UWF). To enable UWF again, do the following:
a Double-click Dell Thin Client Application, navigate to the Auto logon, and then change the default auto logon user name to
User from Admin. Admin or User account referred in this scenario is the local Admin/ User account.
2TPM rmware version 1.2 to version 2.0 upgrade instructions for Wyse 7040 thin client

b On the desktop, double-click the Dell Wyse WF Enable icon.
Write lter is enabled and system reboots.
System automatically logs in to user account because the auto logon is enabled for the User account on the system.
TPM rmware upgrade is complete, and the rmware version is upgraded from version 1.2 to version 2.0.
TPM update procedure using DOS environment
The following are the two scenarios to run TPM update utility using Disk Operating System (DOS) environment:
• Scenario 1: Legacy Boot mode
• Scenario 2: Unied Extensible Firmware Interface (UEFI) Boot mode
Scenario 1: Legacy boot mode
To run the TPM update utility from DOS environment in Legacy boot mode (Non-Windows users), do the following:
1 Copy the downloaded le to a bootable DOS USB key.
2 Power on the system.
3 Press the F12 key and select the USB Storage Device option and boot to DOS.
4 Run the le by typing the copied le name where the executable is located
DOS system automatically restarts , and TPM is updated during the system startup.
When the TPM update is complete, the system automatically reboots.
Scenario 2: UEFI boot mode
To run the TPM update utility from DOS environment in UEFI boot Mode (Non-Windows users), do the following:
1 Copy the downloaded le to a bootable DOS USB key.
2 Power on the system.
3 Press the F2 key.
4 In the BIOS setup, go to General > Boot Sequence > Boot List Option.
5 Change UEFI to Legacy.
6 To save the changes, click Apply > Exit.
7 Restart the system.
8 Press the F12 Key, and select the USB Storage Device option and boot to DOS.
9 Run the le by typing the copied le name where the executable is located
When the TPM update is complete, the system automatically reboots.
10 Press the F2 key to access the BIOS setup.
11 Go to General > Boot Sequence > Boot List Option.
12 Change Legacy to UEFI.
13 To save the changes, click Apply > Exit.
14 Restart the system.
Copyright © 2017 Dell Inc. or its subsidiaries. All rights reserved. Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries. Other
trademarks may be trademarks of their respective owners.
TPM rmware version 1.2 to version 2.0 upgrade instructions for Wyse 7040 thin client 3