Delonghi Eurochef Pro Users Manual HOOD_1_ultimo.p65
EUROCHEF - PRO to the manual 49956b65-79ce-476a-a968-3506ab958dd9
2015-01-24
: Delonghi Delonghi-Eurochef-Pro-Users-Manual-311586 delonghi-eurochef-pro-users-manual-311586 delonghi pdf
Open the PDF directly: View PDF
.
Page Count: 16
| Download | |
| Open PDF In Browser | View PDF |
EUROCHEF - PRO WALL HOOD EUROCHEF - PRO WALL HOOD INSTALLATION INSTRUCTIONS 1 2 3 TIMER Shown with accessory Duct Cover Kit and accessory Warming Lamp Kit APPROVED FOR ALL RESIDENTIAL APPLIANCES FOR RESIDENTIAL USE ONLY PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING. INSTALLATION MUST COMPLY WITH ALL LOCAL CODES. IMPORTANT: Save these Instructions for the Local Electrical Inspector’s use. INSTALLER: Leave these Instructions with this unit for the owner. OWNER: Retain these instructions for future reference. SAFETY WARNING Turn off power circuit at service panel and lock out panel before wiring this appliance. REQUIREMENT: 120VAC, 60 Hz. 20A Branch Circuit READ AND SAVE THESE INSTRUCTIONS EUROCHEF U.S.A. 41 MERCEDES WAY SUITE 25 EDGEWOOD NEW YORK 11717 – TEL. 866-844-6566 WWW.DELONGHIMAJORAPPLIANCES.COM WWW.DELONGHI RANGES.COM Air-2 1 EUROCHEF - PRO WALL HOOD HOODS WEIGHT MODEL NUMBER 24” range hood with 600 CFM blower 22 lbs EC PH24S 30” range hood with 600 CFM blower 30 lbs EC PH30S 36” range hood with 600 CFM blower 36 lbs EC PH36S 48” range hood with 1200 CFM blower 48 lbs EC PH48S FEATURES Controls: Fabrication: Features: ACCESSORIES 4-speed electronic with 15” minute delayed shutoff timer Welded, polished and brushed seams All edges hemmed 304 stainless hood baffle filter and grease tray 12V halogen lighting, lamps included Top and Back ducting 24”, 30”, 36” hoods Transition to 8” round with damper included Install to wall or cabinets MODEL NUMBER WARMING LAMP KIT Includes 175W Warming Lamps, rocker switches, quick connect wiring. Field installable. 24”/30” Warming Lamps Kit: (1) 175W Warming Lamp EC LAMP24/30 36” Warming Lamps Kit: (2) 175W Warming Lamp EC LAMP36 48” Warming Lamps Kit: (2) 175W Warming Lamp EC LAMP48 BACKSPLASH WITH WARMING SHELVES KIT Includes telescoping 2-piece backsplash, removable & dishwasher safe shelves 24” Backsplash with (1) shelf EC BKSPL24 30” Backsplash with (1) shelf EC BKSPL30 36” Backsplash with (2) shelf EC BKSPL36 48” Backsplash with (2) shelf EC BKSPL48 RECIRCULATING KIT Includes 4” high duct cover, 90 degree transition, charcoal filters NOTE: Do not use with indoor BBQ. Do not use with Blower Upgrade Kit (below). 24” Recirculating Kit EC DLK24 30” Recirculating Kit EC DLK30 36” Recirculating Kit EC DLK36 Not Available for 48” Hoods REPLACEMENT CHARCOAL FILTER For use with Recirculating Kit Only Includes 2 Sets of Filters BLOWER UPGRADE KIT Kit for 30” and 36” hoods only. Includes 600 CFM blower. Not for use with Recirculating Kit or horizontal ducting EC FILT EC BLMT DUCT COVER 6” Stackable 304 stainless steel. 24” wide 6” high duct cover EC CVR246W 30” wide 6” high duct cover EC CVR306W 36” wide 6” high duct cover EC CVR366W 48” wide 6” high duct cover EC CVR486W 24” wide 12” high duct cover EC CVR2412W 30” wide 12” high duct cover EC CVR3012W 36” wide 12” high duct cover EC CVR3612W 48” wide 12” high duct cover EC CVR4812W DUCT COVER 12” Stackable 304 stainless steel. 2 Air-2 EUROCHEF - PRO WALL HOOD READ THESE INSTRUCTIONS COMPLETELY AND CAREFULLY WARNING TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: A. Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer. B. Before servicing or cleaning unit, switch power off at the service panel and lock service panel to prevent power from being switched on accidentally. If the service panel cannot be locked, fasten a tag or prominent warning label to the panel. • For general ventilating use only. Do not use to exhaust hazardous or explosive materials or vapors. • Structural framing, installation work and electrical wiring must be done by qualified person(s). In accordance with all applicable codes and standards including tire-rated construction. • Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities. • Local codes vary. Installation electrical connections and grounding must comply with applicable codes. In the absence of local codes, the vent should he in-stalled in accordance with National Electrical Code ANSI/NFPA 701990 or latest edition. ADVERTISSEMENT POUR RÉDUIRE LE RISQUE D’INCENDIE, DE CHOC ÉLECTRIQUE OU DE BLESSURES, IL FAUT OBSERVER LES REGLES SUIVANTES: A. Utiliser cet appareil uniquement de la maniére prévue par le fabricant. En cas de question, consulter le fabricant. B. Avant toute intervention ou nettoyage, couper l’alimentation électrique au disjoncteur et verrouiller le panneau du disjoncteur pour éviter la mise sous tension accidentelle. S’il n’est pas possible de verrouiller le panneau du disconcteur, attacher un placard ou une étiquette trés visible au panneau. • For general ventilating use only. Do not use to exhaust hazardous or explosive materials or vapors. • Structural framing, installation work and electrical wiring must be done by qualified person(s). In accordance with all applicable codes and standards including tire-rated construction. • Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities. • Local codes vary. Installation electrical connections and grounding must comply with applicable codes. In the absence of local codes, the vent should he in-stalled in accordance with National Electrical Code ANSI/NFPA 70-1990 or latest edition. Air-2 CONSIDERATIONS BEFORE INSTALLING HOOD 1. For the most efficient air flow exhaust, use a straight run or as few elbows as possible. 2. Do not use flex ducting use metal ductwork only to reduce the risk of fire. 3. COLD WEATHER installations should have an additional backdraft damper installed to minimize backward cold air flow and a nonmetallic thermal break to minimize conduction of outside temperatures as part of the ductwork. The damper should be on the cold air side of the thermal break. The break should be as close as possible to where the ducting enters the heated portion of the house. 4. Hood installation height above cooktop is the users preference. The lower the hood above the cooktop, the more efficient the capturing of cooking odors, grease, and smoke. This hood has been approved for installations as low as 24 inches* above the cooktop. The lower height may be inconvenient for tall people and large cooking vessels. Consequently, The manufacturer recommends the hood be installed 30-to-36 inches above the countertop. * For indoor grill installations, The manufacturer recommends a minimum of 30" clearance. 5. Make-Up Air: Local building codes may require the use of makeup air systems when using ducted ventilation systems greater than specified CFM of air movement. The specified CFM varies from locale to locale. Consult your HVAC professional for specific requirements in your area. 6. Skill Level - Installation of this vent hood requires basic mechanical and electrical skills. 7. Completion time- 1 to 3 hours. 8. Proper installation is the responsibility of the installer. 9. Product failure due to improper installation is not covered under the Warranty. CAUTION: To reduce risk of fire and to properly exhaust air, be sure to duct air outside - Do not vent exhaust air into spaces within walls or ceilings or into attics, crawl spaces, or garages. PRUDENCE: Il faut prendre soin d’installer tul conduit vers l’extérieur pour réduire le risque d’incendie et pouvoir évacuer l’air correctement. Il ne faut pas évacuer l’air correctement. Il ne faut pas évacuer l’air dans l’espace entre les parois d’un mur, un plafond ou un grenier, un espace sanitaire ou ou garage. WARNING: Any such alteration from original factory wiring could result in damage to the unit and/or create an electrical safety hazard. ADVERTISSEMENT Toute modification de ce type du branchement d’usine pente endommager l’appareil ou créer un risque de choc électrique. 3 EUROCHEF - PRO WALL HOOD PRODUCT DIMENSIONS CONTENTS AND PAGE NUMBER Product Dimensions....................................................... pg.4 Advance Planning...........................................................pg.5 Using Duct Cover Accessories........................................ pg.5 Tools and Materials Required ......................................... pg.5 Remove the packaging................................................... pg.6 Parts Provided............................................................... pg.6 1 Step 1: Determine Ductwork and Wiring Locations............ pg.7 2 3 TIMER 18” Step 2: Prepare hood for installation................................. pg.7 Step 3A: Install Hood Onto Wall...................................... pg.10 Step 3B: Install Hood Beneath Sofit or cabinet................. pg.11 Step 4: Connect Ductwork ............................................ pg.12 Step 5: Connect Electrical ............................................ pg.12 Step 6: Install Duct Covers ........................................... pg.12 24” 24”- 30”- 36”- 48” Step 7: Tighten hanging screws .................................... pg.13 Step 8: Re-Install the Filter Frame ................................. pg.13 Step 9: Install Grease filter trays + filters ........................ pg.14 Step 10: Test hood ...................................................... pg.14 Care and use instructions ............................................ pg.15 4 Air-2 EUROCHEF - PRO WALL HOOD ADVANCE PLANNING 36” (914 mm) Cabinetry and electrical placement for 24-inch deep wall hoods. lnstallatian dimensions for 24 deep wall hoods. USING DUCT COVER ACCESSORIES To avoid gaps, plan the hood installation height for duct cover use. Recirculating Kit Cover 4” (if used) Duct cover 6” Duct cover 12” 1. Duct covers and Recirculating Kit covers are stackable. 2. The hood is 18” tall and can be installed from 24” to 36” above cooking surface (30” to 36” is optimum). 3. Locate hood so that duct covers and Recirculating Kit Cover (If used) leave no gap between hood and ceiling. TOOLS AND MATERIALS REQUIRED (NOT SUPPLIED) 8 Air-2 5 EUROCHEF - PRO WALL HOOD REMOVE THE RANGEHOOD Parts Included with your Hood DO NOT GRAB BODY HERE GRAB BODY HERE GRAB BODY HERE • Hood with blower installed • 12-Volt halogen bulbs, installed • Care & Use /Installation Instructions • Registration Card • Filters (24” & 30” = 2; 36” = 3; 48” = 4) • Grease trap (24” & 30” = 2; 36” = 3; 48” = 4) • Transition with Back draft damper • Fasteners • Wooden bracket for Hood Support Parts Not Included with your Hood LOCATION OF COMPONENTS PARTS PROVIDED Locate the parts packed with the hood. • Duct Cover Kit, 6" or 12" height • Warming lamp kit • Back Splash + Warming shelf kit • Blower upgrade kit for 30” - 36” models only • Recirculating kit • See your dealer to purchase these kits Washers no. 4 for 24”-30” no. 6 for 36”-48” for use with screws to attach hood to Bracket Duct Transition Screws to hang and secure hood to the Wood Bracket (torx 20) 4,5 x 20 mm no. 4 for 24”-30” no. 6 for 36”-48” Washers no. 3 6 x 24 for use with screws to anchor hood no.3 screws and no.3 wall anchors (Philips) M5 x 57 mm Grease Trays (2 with 24”, 30” models) (3 with 36” models) (4 with 48” models) no. 4 screws 80mm to attach wood bracket to wall studs (torx 25) Stainless Steel Grease Filters (2 with 24”, 30” models) (3 with 36” models) (4 with 48” models) HARDWARE PACKAGE Locate and check contents. Screws shown actual size no. 4 screws to fix duct transition (torx 20) 3,9 x 9,5 mm Wood bracket 6 Air-2 EUROCHEF - PRO WALL HOOD STEP 1 DETERMINE HOOD, DUCTWORK AND WIRING LOCATIONS • • Use a level to draw the cooktop centerline vertically up the wall to the ceiling. Measure desired distance from the bottom of the hood to the cooking surface, 24" min. to 36" max. Note: If installing with Duct Cover Kit or Recirculating Kit, see “Using Duct Cover Accessories”, pg 5 to eliminate gaps at ceiling. • Use a level to draw a straight horizontal pencil line indicating the bottom of the hood. FOR VERTICAL (Straight Up) DUCTING: • • • Affix enclosed paper template to wall. If venting out the ceiling, extend the centerline forward on the ceiling or soffit. Locate the centerline of a 8-1/2" diameter hole on the ceiling or soffit by measuring 6" from the wall. REMOVE FILTER FRAME - Remove Filter Frame per photographs - Store Filter Frame in safe place so it will not be damaged. - Do not loose the Filter Frame screws, re-screw them loosely, back into the hood. OTHER PREPARATIONS • • • • • • • Move blower to back if necessary. Install transition to top or back. If using Recirculating Kit, affix 90° transition from kit. Must install the hood to the wall. (step 3A) If using Warming Lamps Kit: install kit now or later. If using Blower Upgrade Kit ( 30”-36” only): install kit now or later. Move junction box from top to back if preferred. Install strain relief in junction box JUNCTION BOX LOCATION: • • FOR DUCTING THROUGH WALL PLEASE SEE TEMPLATE: The junction box is fastened to the top of the hood. Relocate to back if preferred. Remove junction box cover and one knockout. Install strain relief. Use template to identify wall exit hole location, wood wall bracket location, and wiring location. STEP 2 PREPARE HOOD FOR INSTALLATION Install Transition Onto Top or Back of Hood IMPORTANT: Remove shipping tape from damper and check that damper moves freely. • • Air-2 Duct Transition Top of Hood Place the transition piece over the hood exhaust and secure with 4 screws provided. Use duct tape to seal the connection. Check to be sure the damper moves freely. 7 EUROCHEF - PRO WALL HOOD BLOWER POSITION CHART Hood size Motor Recirculating Kit option Top ducting option Rear ducting option 24” 30” 30” 36” 36” 48” 1 1 2* 1 2* 2 YES YES NO YES NO NO YES YES YES YES YES YES YES YES NO YES NO NO (*) with Blower Upgrade Kit BLOWER POSITION OPTION model 24 Vertical Discharge model 30 36 Vertical Discharge model 30 36 model 48 two blowers Vertical Discharge (with Blower Upgrade Kit) model 24 Horizontal Discharge model 30 36 Horizontal Discharge model 30 36 model 48 two blowers Horizontal Discharge (2 Blower may Not Duct out Rear) 8 Air-2 EUROCHEF - PRO WALL HOOD IF CHANGING BLOWER POSITION SECURITY SCREW 1. Disconnect motor from power supply 2. Remove Blower security screw from blower bracket and remove blower. 3. Loosen 4 screws from blower bracket. 4. Shift blower to right and Remove Blower. 5. Loosen 4 screws and remove sealing plate covering back venting hole. 6. Reverse this procedure in new locations. 7. Reconnect blower to power supply. BLOWER UPGRADE KIT 30” AND 36” HOODS A “A”: remove bracket knock out before fixing 2nd motor 1. 2. 3. 4. Follow steps 1, 2, 3, 4 above. Remove blower from bracket Remove knockout from blower bracket Re-attach blower and blower upgrade kit with screws provided. 5. Re-attach blower to top of hood only. Double Blowers may not be installed on back of hood. 6. Tighten 4 screws, and screw in one security screw. 7. Each Blower must be connected to the hood power supply. Air-2 WARNING: • disconnect the motor before changing position; reconnect after it is moved. ATTENTION: Débrancher le moteur avant de changer de position, rebrancher après le changement de position 9 EUROCHEF - PRO WALL HOOD STEP 3A: INSTALL HOOD ONTO WALL (see enclosed template) SKIP THIS STEP IF INSTALLING BENEATH A SOFFIT OR CABINET, GO TO STEP 3B. • • • • Affix enclosed paper template to wall. From the line indicating the bottom of the hood, measure 17” up and draw another line for the location of the Wood Bracket. See illustration. Locate at least 2 vertical studs at the Wood Bracket. Center the supplied Wood Bracket, left to right and below the marked line. • Insert hood mounting screws in the Wood Bracket at the locations shown in the diagram, so screws protrudes 1/4". This 1/4” gap will provide clearance to hang the hood. IMPORTANT: FRAMING MUST BE CAPABLE OF SUPPORTING UP TO 150 LBS Hang Hood On Wood Bracket • • • • Lift the hood and hold close to the installation location. Route house wiring through the knockout and into the junction box. Place the hood over the Wood Bracket. Be sure the mounting screws engage the keyhole slots in the back of the hood. Check to be sure the hood is level and centered. Use midpoint arrow in back of hood to confirm horizontal position. 1 24 • Secure the Wood Bracket to 2 or more vertical studs, using at least 2 of the 4 supplied long screws. 2 3 TIMER Centerline of Installation Space IMPORTANT: Screws must penetrate at least 1-1/2" into vertical studs. Countersink screws into support. Test Duct Cover Fit (do not install Duct covers) AFFIXING THE HOOD MOUNTING SCREWS • x 30” 11” 36” 14” 48” 20” • • 2” 8” x x 1 5/16” 24” Place duct covers or recirculating cover over the top of the hood to check for gaps. Confirm that the ceiling gap, if any, is less then 3/8”. If gap is greater than 3/8", OR if duct covers do not fit, it is necessary to remove, re-measure and reinstall the Wood Bracket. Original Mounting Screws as Shipped 10 Air-2 EUROCHEF - PRO WALL HOOD STEP 3B: ALTERNATE MOUNTING METHOD • Affix enclosed paper template to wall IMPORTANT: FRAMING MUST BE CAPABLE OF SUPPORTING UP TO 150 LBS INSTALL HOOD TO SOFFIT OR BENEATH CABINETS SKIP THIS STEP IF USING WALL MOUNTING METHOD When necessary, the hood may be installed so that it is supported by the soffit. • The soffit should be constructed with 2 x 4’s. • Determine the installation location on the wall. • Continue the centerline forward on the bottom of the cabinet or soffit. • If ducting vertically the opening above the hood should allow for the 8" round duct and clearance to slide the hood back against the wall. Requires 8" Min. Opening For Ductwork and Hood Installation Mount Hood onto Soffit or Cabinet Note: If mounting to the underside of a cabinet with a recessed bottom, install shims to fill the gap. Requires 8” Min. Opening For Ductwork and Hood Installation • • • • The 2 x 4 studs must be located as shown in the chart, Dim. A. to accept mounting screws. “A” Centerline to Stud and Keyhole Slots PRO HOOD 24” PRO HOOD 30” PRO HOOD 36” PRO HOOD 48” 11 - 9/16” 14 - 9/16” 17 - 9/16” 23 - 9/16” • • Drive mounting screws into the studs until they protrude 1/4". The 1/4" gap will provide clearance to engage the keyhole slots in the top of the hood. Lift hood to installation position. Locate house wiring and route through the knockout (from the back or top of the hood). Lift hood onto mounting screws. Slide back against the rear wall. Tighten mounting screws. Add (2) security screws in top left and top right side of hood. IMPORTANT: For additional support and to minimize vibration during operation, the hood must be secured to the back wall. Use wall anchors to fasten bottom back of hood to the wall. 3” ½ 9” 3/4 C L A Top of hood • Air-2 Drill 1/8" pilot holes into the studs at the locations shown in the top view illustration. 11 EUROCHEF - PRO WALL HOOD STEP 4: • • CONNECT DUCTWORK Install ductwork. Secure joints in ductwork and transition with sheetmetal screws and duct tape for an airtight seal. ATTENTION: Be sure that screws do not hamper the dampers movement. • STEP 5: • • Use wire nuts to connect incoming ground, neutral and hot. Push wires into junction box and replace cover. Be sure wires are not pinched. STEP 6: INSTALL DUCT COVERS CONNECT ELECTRICAL Verify that power is turned off at the source. WARNING If house wiring is not 2-wire with a ground wire, a ground must be provided by the installer. When house wiring is aluminum, be sure to use U.L. approved anti-oxidant compound and aluminum-to-copper connectors. ATTENTION Sí le câblage de la maison n’est pas du type a deux fils avec un fil de terre, l’installateur doit fournir un circuit de terre. Quand les fils de la maison sont en aluminium, il prendre soin d’utiliser de la pâte antioxidation approuvée par UL et des connecteurs pour l’aluminium-cuivre. GREEN = GROUND BLACK & BROWN = HOT BLUE & WHITE = NEUTRAL 12 ASSEMBLY AND INSTALLATION OF THE DUCT COVERS & RECIRCULATING KIT COVER Optional duct covers shown in advance planning section may be used to fill the space between the hood and ceiling in wall mount installations. 6" and 12" high duct covers are available and may be ordered separately. 1. If multiple duct covers are used, connect the pieces together using sheetmetal screws provided with duct covers. Remove plastic film. 2. Attach the duct cover(s) to the hood using screws provided. 3. From inside of hood, insert screws supplied (3,5 x 9,5) through holes in front and side of hood into covers. Air-2 EUROCHEF - PRO WALL HOOD STEP 7: • • • • TIGHTEN - HANGING SCREWS With Filter Frame still removed from Step 2 Adjust hood up to eliminate any gaps at ceiling. Tighten hanging screws. Add (2) more security screws + Washers at wood bracket. IMPORTANT: If Installing optional Backsplash Kit install this kit BEFORE installing wall anchors (see instruction with kit) Install Bottom Wall Anchors • • • • Drill 1//8" pilot holes into the two lower mounting holes. Enlarge the holes if they did not enter studs to 3/8". Install (2) or (3) wall anchors at bottom of hood. Remove anchor screws and add a flat washer provided. Drive screws into anchors and tighten. If a Wood Stud was discovered at wall anchor locations use 80mm Wood Screw supplied with Washer (instead of Wall anchor). Drive screws and tighten. STEP 8: RE-INSTALL THE FILTER FRAME • Use screws removed in Step 2 to re-install Filter Frame, per photograph. Air-2 13 EUROCHEF - PRO WALL HOOD STEP 9: INSTALL FILTER STEP 10: TEST FUNCTION OF HOOD - Blower - Light • Place filter drip trays into the bottom rear of the hood. • Insert top of grease filter first, than rotate bottom filter and drop into grease tray. • To remove the filters, grasp the handle, push the filter up and lift out. 14 Air-2 EUROCHEF - PRO WALL HOOD CARE AND USE OPERATION REPLACING HALOGEN BULB Press any speed to turn hood on. Press same button to turn hood off. Active speed is shown by a button back light. ROTATE CONTROL: 1. 2. 3. 4. 1 Speed 2 Speed 3 Speed 4 Speed Light DELAYED SHUTOFF By pressing down on any speed key for 2 seconds, while hood is running the 15 minute Delayed Shutoff mode will start indicated by flashing backlight. After 15 minutes the hood will shutoff. WARRANTY: Eurochef USA warrants the USA Pro Hood against defects in materials or workmanship for 1 year from date of purchase. • After waiting for lamp to be cool, twist off lamp bezel as shown, and pull out bulb. • Replace bulb with 20W G4 base halogen bulb purchased at your local hardware store. • Follow instructions on the bulb. Do not touch the bulb with your bare fingers. • Reinstall lamp bezel CLEANING FILTERS EUROCHEF U.S.A. 41 MERCEDES WAY SUITE 25 EDGEWOOD, NEW YORK 11717 TEL. 866-844-6566 WWW.DELONGHIMAJORAPPLIANCES.COM WWW.DELONGHI RANGES.COM Clean grease trays and baffle filters regularly, at least once every 3 months. Filters and tray are dishwasher safe. CLEANING HOOD Do not use abrasive products Wipe the outside of stainless steel with sudsy water or household cleaners such as Fantastic or Formula 409. Rinse well and dry with soft cloth. Air-2 15 EUROCHEF - PRO WALL HOOD EUROCHEF U.S.A. 41 MERCEDES WAY SUITE 25 EDGEWOOD NEW YORK 11717 – TEL. 866-844-6566 WWW.DELONGHIMAJORAPPLIANCES.COM WWW.DELONGHI RANGES.COM 16 Air-2
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : Yes Create Date : 2006:10:24 17:21:36+02:00 Modify Date : 2006:10:24 17:21:36+02:00 Page Count : 16 Creation Date : 2006:10:24 15:21:36Z Mod Date : 2006:10:24 15:21:36Z Producer : Acrobat Distiller 5.0 (Windows) Author : Katia Metadata Date : 2006:10:24 15:21:36Z Creator : Katia Title : PRO HOOD_1_ultimo.p65EXIF Metadata provided by EXIF.tools