SNAP-IN MOUNTING HIGH PERFORSERIES MANCE IEC CONNECTOR FILTERS
INTRODUCTIONS

SPECIFICATIONS

1. Snap-in mounting type to reduce labor cost.
Compact and reliable at low cost.
2. Bleeder resistor can be added with suffix "-R"
on part numbers,except G3H,G3V,W3V,G3J,W3J,types.
3. Optional side snap-in mounting clip type with suffix (H) on part
numbers.
4. All part numbers are UL recongnized, CSA certified and VDE

approved.

COMPONENTS

*

INSERTION LOSS (TYPICAL)
Cx (uF)

L (mH)
6.5
2.5
2.5
4
0.8
1.5
0.8
0.2
0.4
0.3
0.2
0.2
0.3

0.1

**
***

UL, CSA approved to 4A 115/250V
UL, CSA approved to 8A 115/250V
VDE approved to 8A/250V

IEC INLET FILTERS

1. Maximum leakage current each
line-to-ground @ 115VAC 60Hz: 0.2mA
@ 250VAC 50Hz: 0.4mA
2. Hipot rating (one minute)
line-to-ground: 2250VDC
line-to-line: 1450VDC
3. Operating frequency: 50/60Hz
4. Rated voltage: 115/250VAC

5. With optional Y-Cap from 100pF to 3300pF.
6. Safety under apply for 03/06/10GENG3U(H) series.

PART NO.
01GENG3E/W3E/-R
03GENG3E/W3E/G3U(H)/-R
03GENW3ES/-R
03GENG3Q/W3Q/-R
06GENG3E/W3E/G3U(H)/-R
06GENG3Q/W3Q/-R
06GENW3ES/-R
10GENG3E/W3E/G3U(H)/-R
10GENG3C/W3C/-R
10GENG3Q/W3Q/-R
10GENW3ES/-R
15GENG3E/W3E/-R
20GENG3E/W3E/-R

V
D E

*
**
***

Cy (pF)

R(

)

03GENG3E
06GENG3E

COMMON MODE
COMMON MODE

DIFF. MODE
DIFF. MODE

80 dB

2200

1M

60 dB

40 dB

20 dB

UL, CSA approved to 13A 115/250V
VDE approved to 10A/250V
VDE approved to 16A/250V

0 dB

10K

100K

1M

10M

MINIMUM INSERTION LOSS IN dB
COMMON MODE (L-G) IN 50 OHM SYSTEM
CURRENT
FREQUENCY-MHz
RATING
.15
.50
1.0
5.0
1A
28
35
38
38
3A
20
25
30
38
6A
12
18
24
35
6A (G3Q)
15
20
24
35
10A
4
10
13
28
10A (G3C)
10
15
15
25
10A (G3Q)
10
12
15
30
15A
4
10
13
28
20A
8
10
15
25

20GENG3E
10
40
40
40
40
35
30
32
35
30

COMMON MODE

DIFF.MODE

80 dB

30
40
40
40
55
40
35
45
40
35

60 dB

40 dB

20 dB

ELECTRICAL SCHEMATIC

0 dB

L

N

L'
L
I
N
E

R

Cx

Cy
Cy

G

L
O
A
D

N'
G'

R: 1M /-R ONLY

2-7

10K

100K

1M

10M

PANEL

Suggested thickness of mounting panel is from
0.0315 (0.8) to 0.063 (1.6) inch(mm) of mounting cutout

PCB

ASSEMBLY FROM FRONT

MECHANICAL CONSTRUCTION

0.84MAX.
21.4MAX.

L

N
G

0.862 0.004
21.9 0.1

1.66MAX.
42.16MAX.

2.1MAX.
53.4MAX.

+0.012
1.12 - 0
+0.3
28.45 - 0

R0.08MAX.
R2.0MAX.

0.0315~0.06
0.8~1.6

SUGGESTED MOUNTING CUTOUT

NG3E, NG3C, NG3Q (Optional wire type)

1.12 MAX.
28.4 MAX.

GENG3E
L

0.84MAX.
21.4MAX.

1.22 0.02
31.0 0.5

N
G
+0.04
0.142 - 0.02
+1.0
3.6 - 0.5

0.945 0.02
24.0 0.5

0.85 0.004
21.5 0.1

2.1MAX.
53.4MAX.

1.66MAX.
42.16MAX.

R0.08MAX(2X)
R2.0MAX

1.16 0.004
29.5 0.1

0.0315~0.063
0.8~1.6

SUGGESTED MOUNTING CUTOUT

NG3E(H), NG3C(H), NG3Q(H) (Optional wire type)

1.12 MAX.
28.4 MAX.

GENG3E(H)

G

0.94 0.02
24.0 0.5

N

L

0.80 0.02
20.4 0.5

1.22 0.02
31.0 0.5

+0.04
0.11-0.02
+1.0
2.8-0.5
R0.08MAX.
R2.0MAX.

1.94 0.04
49.4 1.0

1.50 0.02
38.0 0.5

0.85 0.004
21.9 0.1

0.8~1.6

1.12 0.02
28.4 0.5
1.16 0.004
29.5 0.1

NG3U(H) (With Compact Size)

31.0 0.5

1.12 MAX.

0.84MAX.
21.3MAX.

24.0 0.5

+0.012
1.12 - 0
+0.3
28.45 - 0

R0.08MAX.
R2.0MAX.

0.0315~0.06
0.8~1.6

SUGGESTED MOUNTING CUTOUT

BLUE

NW3ES

G/Y

28.4 MAX.

0.862 0.004
21.9 0.1

1.22 0.2

+0.04
0.142 -0.02
+1.0
3.6 -0.5

N
G

1.575 MAX.
40.0 MAX.

L

0.945 0.02

NG3U(H)

BROWN

NW3ES

2.60MAX.
66.0MAX.

0.138
3.5
3.19MAX.
81.0MAX.

20GENG3E (Optional wire type)
2-8

+0.02
1.043-0
+0.5
26.5-0

1.496MAX.
38.0MAX.

1.18
30.0

1.36MAX.
34.5MAX.

0.248X0.031
6.3X0.8

1.04MAX.
26.5MAX.

IEC INLET FILTERS

+0.04
0.142 - 0.02
+1.0
3.6 - 0.5

0.945 0.02
24.0 0.5

1.22 0.02
31.0 0.5

R0.118MAX.
R4.0MAX.

+0.02
1.417-0
+0.5
36.0-0

SUGGESTED MOUNTING CUTOUT
(MOUNTING FROM REVERSE)

ALL WIRE LEADS 4.0" LONG MIN.

UNIT: INCH
mm



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Page Count                      : 2
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:6a6201f3-6bdd-42b0-a735-be6d847ba4fb
Modify Date                     : 2008:06:25 14:10:54+08:00
Create Date                     : 2008:06:25 14:10:46+08:00
Metadata Date                   : 2008:06:25 14:10:54+08:00
Document ID                     : uuid:16ef9d3f-41e7-47f9-adf4-c09515619810
Format                          : application/pdf
Title                           : 04_2-1~3-1_15P-80327
Creator                         : CorelDRAW Version 9.397
Author                          : OPC
Producer                        : Corel PDF Engine Version 9.397
EXIF Metadata provided by EXIF.tools

Navigation menu