RS-485 Connector RJ-11 Transmission method RS-485 Transmission speed 110, 150, 300, 600, 1,200, 2,400, 4,800, 9,600, 19,200, 38,400, 57,600, 115,200 Communication format Stop bit: 1,2 Communication protocol Modbus, User Define PIN Signal 1 Parity bit: None, Odd, Even Data bit: 7,8 ASCII/RTU Interface Mini Dim Transmission method RS-232 Transmission speed 110, 150, 300, 600, 1,200, 2,400, 4,800, 9,600, 19,200, 38,400, 57,600, 115,200 Communication format Stop bit: 1,2 Parity bit: None, Odd, Even Data bit: 7,8 Communication protocol -- Modbus, Delta Configuration, User Define Transmission cable DVPACAB215 / DVPACAB230 / DVPACAB2A30 N/C 4 D- Negative pole for data -- N/C 5 GND Ground Positive pole for data 6 -- N/C PIN Signal Definition PIN Signal Definition 1 Tx+ Positive pole for data transmission 5 -- N/C 2 Tx- Negative pole for data transmission 6 Rx- Negative pole for data receiving 3 Rx+ Positive pole for data receiving 7 -- N/C N/C 8 4 Interface Feed-through terminal 10PIN Transmission method RS-485 Transmission distance 1,200m Transmission speed 110, 150, 300, 600, 1,200, 2,400, 4,800, 9,600, 19,200, 38,400, 57,600, 115,200 Communication format Stop bit: 1,2 Communication protocol Modbus, User Define -- -- Parity bit: None, Odd, Even Data bit: 7,8 ASCII/RTU N/C Definition PIN Signal Definition -- N/C 5 Tx Transmission data 2 -- N/C 6 -- N/C 3 -- N/C 7 -- N/C 1 4 Rx Reception data 8 GND Ground 2 PIN Signal Definition 1 SG Ground of signal 2 D- Data- 3 D+ Data+ Insulation voltage 500V 4 X2 Digital input 2 Weight 140g 5 X1 Digital input 1 6 X0 Digital input 0 7 S/S Ground of digital input 8 24V +24V 9 0V 0V 10 -- Earth ground ESD (IEC 61131-2, IEC 61000-4-2): 8KV Air Discharge EFT (IEC 61131-2, IEC 61000-4-4): Power Line:±2KV, Digital Input: ±2KV, Communication I/O: ±2KV RS (IEC 61131-2, IEC 61000-4-3): 80MHz ~ 1GHz, 10V/m. 1.4GHz ~ 2.0GHz, 10V/m Conducted Susceptibility Test (EN61000-4-6, IEC61131-2 9.10): 150KHz ~ 80MHz, 3V/m Surge Test (Biwave IEC61132-2, IEC61000-4-5): Power line 0.5KV DM, Ethernet 0.5KV CM, RS-485 0.5KV CM Operation: 0ºC ~ 55ºC (temperature), 50 ~ 95% (humidity), pollution degree 2 Storage: -25ºC ~ 70ºC (temperature), 5 ~ 95% (humidity) International standards: IEC61131-2, IEC68-2-6 (TEST Fc)/IEC61131-2 & IEC 68-2-27(TEST Ea) Installation 4 5 6 7 9 digital display shows the address of and errors in IFD9506 and the error messages from the slave. POWER LED Indication How to correct Working power is abnormal Check if the working power of IFD9506 is normal. Green light ON Working power is normal -- RS-485 Indication OFF No communication or RS-485 connection is abnormal. Constantly ON Abnormal RS-485 connection Switch D+ and D- Green light flashes RS-485 connection is normal. -- LED status Features 1. Auto-detects 10/100 Mbps transmission speed; MDI/MDI-X auto-detection. RS-232 3. Supports Modbus TCP protocol (supports Master and Slave mode) Unit: mm Content Valid Modbus communication address 3 Address switch 4 Data format/baud rate switch indicator, Reset button, 6 RS-485 Ethernet indicator 9 Data Format Switch Switch setting Format Green light ON The connection is normal, but no -data transmission. Green light flashes The data transmission is normal. -- Format Code Indication 01 ~ F7 The node address of IFD9506 when in normal operation -- F0 Returning to default setting -- F1 IFD9506 is booting -- F2 Working power in low voltage Check if the working power is normal. F3 Internal memory error 1. Re-power IFD9506. If the error still exists, try step 2. 2. Reset IFD9506. If the error still exists, send it back to the factory for repair. Internal error caused by manufacturing in the factory 1. Re-power IFD9506. If the error still exists, try step 2. 2. Reset IFD9506. If the error still exists, send it back to the factory for repair. F4 0 1 8-N-1 9 8-N-2 F5 Network connection error Check if IFD9506 is normally connected to the network. 2 7-O-1 A 7-O-2 F6 Check if the number is too much. 9 DIN rail connector Full number of devices connected in the network 3 8-O-1 B 8-O-2 F7 UART setting error. Check if the RS-485, RS-232 communication format is correct. 6 7-E-1 E 7-E-2 E1 Alarm 1 triggered Check Alarm Input Point 1. 7 8-E-1 F 8-E-2 E2 Alarm 2 triggered Check Alarm Input Point 2. E3 Alarm 3 triggered Check Alarm Input Point 3. 01 02 Incorrect MODBUS function Incorrect address Check if the Modbus instruction is correct. 03 Incorrect data Check if the Modbus instruction is correct. 04 CRC error 1. Check if IFD9506 and RS-485 is connected normally. 2. Check if the series transmission speed is consistent with that of other nodes on the network. No response from the station 1. Check if IFD9506 and RS-485 is connected normally. 2. Check if the series transmission speed is consistent with that of other nodes on the network. RJ-45 with Auto MDI/MDIX Transmission method Ethernet Type II Transmission cable Category 5e, 100m (Max) Transmission speed 10/100 Mbps Auto-Detection Network protocol ICMP, IP, TCP, UDP, DHCP, SMTP, MODBUS OVER TCP/IP, Delta Configuration 7-N-2 How to correct connector, digital input points, 8 RS-485 power input point, earth point Ethernet Interface 8 7 Module name Specifications 7-N-1 Switch setting 1. Check the power of IFD9506 and make sure the network connection is normal. 2. Re-power IFD9506. If the error still exists, send your IFD9506 back to the factory for repair. Codes in Digital Display Address Switch 5 Digit display Baud Rate Switch Switch setting 接頭 傳輸方式 傳輸速率 通訊格式 通訊協定 傳輸電纜 How to correct No power, or no network connection 4. Able to send out emails after being triggered. 5. The station address, RS-485 communication format and baud rate can be set up externally. Indication OFF 2. The monitor table temporarily stores the monitored data for the user to fast save or acquire the data. 接頭 傳輸方式 傳輸速率 通訊格式 通訊協定 How to correct 1. If the LED is off during the communication, check if the RS-485 in IFD9506 is normally connected. 2. Check at least 1 node on the network is communicating normally. LINK/ACT LED Introduction 接頭 傳輸方式 傳輸電纜 傳輸速率 網路協定 working power. RS-485 and LINK/ACT indicators display the connection status of the communication. The OFF Baud rate (bps) Switch setting Baud rate (bps) 1 110 7 4,800 2 150 8 9,600 3 300 9 19,200 4 600 A 38,400 5 1,200 B 57,600 6 2,400 C 115,200 0B 功能規格 Ethernet There are 3 LED indicators and a digital display on IFD9506. POWER indicator displays the status of the LED status 8 9 LED Indicators & Trouble-Shooting LED status Dimension 01 … F7 3 RS-485 LED or specific tools are required to open the enclosure) in case danger and damage on the device may occur. 2 Power indicator 產品外觀 Signal 24V DC (-15% ~ 20%) supplied by feed-through terminal Switch setting 4. 1 3W electric shock and vibration. The enclosure should prevent non-maintenance staff from operating the device (e.g. key ports: RS-485, 1 Communication Ethernet, RS-232 2. Feed-through Terminal PIN Definition Certificates Product Profile & Outline 自動偵測 10/100 Mbps 傳輸速率,MDI/MDI-X 自動偵測。 提供 Monitor table 可暫存監控的資料,讓使用者快速存取。 支援 Modbus TCP 協定 (支援 Master 和 Slave 模式)。 經觸發後發送電子郵件。 可由外部設定站號、RS-485 通訊格式、鮑率。 可由 Web 設定通訊參數。 1. 6. 產品簡介 功能特色 PIN Power consumption 6. The communication parameters can be set up through Web. 繁體中文 此安裝手冊只提供電氣規格、一般規格、安裝及配線等。 配線時請務必關閉電源,請勿在上電時觸摸任何端子。 本機為開放型 (OPEN TYPE) 機殼,因此使用者使用本機時,必須將之安裝於具防塵、防潮及免於電擊∕ 衝擊意外之外殼配線箱內。另必須具備保護措施(如:特殊之工具或鑰匙才可打開),防止非維護人員操作 或意外衝擊本體,造成危險及損壞。 5. Power voltage Vibration/shock immunity 3. RS-232 PIN Definition Operation/storage Interface Definition D+ Environment Warning Signal 3 Electrical Specifications This instruction sheet only provides introductory information on electrical specification, installation and wiring. Switch off the power before wiring. DO NOT touch any terminal when the power is switched on. IFD9506 is an OPEN-TYPE device and therefore should be installed in an enclosure free of airborne dust, humidity, PIN 2 ASCII/RTU Terminal Block ENGLISH Definition RJ-45 PIN Definition RS-232 Connector Noise immunity 注意事項 RJ-11 PIN Definition Interface Check if the Modbus instruction is correct. 通訊口 電源指示燈 站號設定開關 通訊格式、通訊速率設定開關 數位顯示器 RS-485 指示燈、Reset 按鍵、 Ethernet 指示燈 模組名稱 端子台 RS-485 連接器、數位輸入 點、電源輸入、大地 DIN 軌連接器 RS-485, Ethernet, RS-232 連接器 RJ-45 with Auto MDI/MDIX Ethernet Type II Category 5e, 100 公尺 (Max) 10/100 Mbps Auto-Detection ICMP, IP, TCP, UDP, DHCP, SMTP, MODBUS OVER TCP/IP, Delta Configuration 連接器 RJ-11 RS-485 110, 150, 300, 600, 1,200, 2,400, 4,800, 9,600, 19,200, 38,400, 57,600, 115,200 Stop bit: 1,2 Parity bit: None, Odd, Even Data bit: 7,8 ASCII/RTU Modbus, User Define 連接器 端子台連接器 接頭 傳輸方式 傳輸距離 傳輸速率 通訊格式 通訊協定 電氣規格 電源電壓 消耗電力 絕緣電壓 重量 環境規格 雜訊免疫力 Mini Dim RS-232 110, 150, 300, 600, 1,200, 2,400, 4,800, 9,600, 19,200, 38,400, 57,600, 115,200 Stop bit: 1,2 Parity bit: None, Odd, Even Data bit: 7,8 ASCII/RTU Modbus, Delta Configuration, User Define DVPACAB215 / DVPACAB230 / DVPACAB2A30 歐式端子台 10PIN RS-485 1,200m 110, 150, 300, 600, 1,200, 2,400, 4,800, 9,600, 19,200, 38,400, 57,600, 115,200 Stop bit: 1,2 Parity bit: None, Odd, Even Data bit: 7,8 ASCII/RTU Modbus, User Define 24V DC (-15% ~ 20%) 由歐式端子台輸入 3W 500V 140g ESD (IEC 61131-2, IEC 61000-4-2): 8KV Air Discharge EFT (IEC 61131-2, IEC 61000-4-4): Power Line:±2KV, Digital Input: ±2KV, Communication I/O: ±2KV RS (IEC 61131-2, IEC 61000-4-3): 80MHz ~ 1GHz, 10V/m. 1.4GHz ~ 2.0GHz, 10V/m Conducted Susceptibility Test (EN61000-4-6, IEC61131-2 9.10): 150KHz ~ 80MHz, 3V/m Surge Test (Biwave IEC61132-2, IEC61000-4-5): Power line 0.5KV DM, Ethernet 0.5KV CM, RS-485 0.5KV CM 0ºC ~ 55ºC(溫度)、50 ~ 95%(濕度)、污染等級 2 操作∕儲存環境 操作: 儲存:-25ºC ~ 70ºC(溫度)、5 ~ 95%(濕度) 耐震動∕/衝擊 國際標準規範 IEC61131-2, IEC68-2-6 (TEST Fc)/IEC61131-2 & IEC 68-2-27(TEST 標準 Ea) 安裝 RS-485 外觀 燈狀態 LED 燈顯示說明 燈滅 綠燈恆亮 綠燈閃爍 顯示說明 處理方法 IFD9506 的 RS-485 確認連接正常。 無通訊或 RS-485 連線不正常 1.2. 如通訊中燈滅,檢查 確認網路上至少有一個節點可以正常通訊。 RS-485 接線不正常 D+、D- 對調 RS-485 連線正常 無需處理 LINK/ACT 燈狀態 LED 燈滅 綠燈亮 綠燈閃爍 位址開關設置 01 ~ F7 F0 F1 開關設置 說明 01 … F7 有效的 Modbus 通訊位址 通訊格式開關設置 F2 F3 F4 旋鈕值 通訊格式 旋鈕值 通訊格式 0 7-N-1 8 7-N-2 F7 1 8-N-1 9 8-N-2 E1 2 7-O-1 A 7-O-2 E2 3 8-O-1 B 8-O-2 E3 6 7-E-1 E 7-E-2 01 7 8-E-1 F 8-E-2 02 通訊速率開關設置 鮑率 (bps) 旋鈕值 鮑率 (bps) 1 110 7 4,800 2 150 8 9,600 3 300 9 19,200 4 600 A 38,400 5 1,200 B 57,600 6 2,400 C 115,200 腳位 F5 F6 03 旋鈕值 RJ-11 連接器的腳位定義 0B 敘述 腳位 1 -- N/C 4 D- 2 -- N/C 資料正極 5 GND 敘述 資料負極 參考地 6 -- N/C 腳位 3 D+ 腳位 連接器的腳位定義 1 Tx+ 2 訊號 Tx- 3 Rx+ 敘述 傳輸資料正極 傳輸資料負極 接收資料正極 4 -- 腳位 訊號 04 訊號 RJ-45 訊號 敘述 -- 6 Rx- 接收資料負極 7 -- N/C 1. N/C 8 -- N/C 2. 訊號 敘述 腳位 訊號 5. 1 -- N/C 5 Tx 敘述 傳輸資料 2 -- N/C 6 -- N/C 3 -- N/C 7 -- N/C 4 Rx 8 GND 連接器的腳位定義 接收資料 歐式端子台的腳位定義 腳位 訊號 1 SG 2 D- 3 D+ 4 X2 5 X1 6 X0 7 S/S 8 24V +24V 9 0V 10 -- 大地 參考地 通訊模組有三個 LED 指示燈和一個數位顯示器。POWER LED 用來顯示 IFD9506 的工作電源是否正常; 與 LINK/ACT LED 用來顯示 IFD9506 的通訊連接狀態;數位顯示器用來顯示 IFD9506 通訊模組的 站號、錯誤資訊以及從站的錯誤訊息。 IFD9506 RS485 LED POWER 燈顯示說明 LED 燈狀態 顯示說明 燈滅 工作電源不正常 綠燈亮 工作電源正常 處理方法 檢查 IFD9506 工作電源是否正常 無需處理 錯誤 站台無回應 無需處理 無需處理 無需處理 檢查通訊模組的工作電源是否正常 1. 將通訊模組重新上電,如果錯誤依然存在,進行步驟 2。 2. 將通訊模組重置,如果錯誤依然存在,退回原廠進行修復。 1. 將掃描模組重新上電,如果錯誤依然存在,進行步驟 2。 2. 將通訊模組重置,如果錯誤依然存在,退回原廠進行修復。 確認通訊模組與網路連接正常 確認是否連線數過多 確認 RS-485, RS-232 通訊格式是否正確 查看警報輸入點 1 查看警報輸入點 2 查看警報輸入點 3 檢查 Modbus 指令是否正確 檢查 Modbus 指令是否正確 檢查 Modbus 指令是否正確 1. 檢查通訊模組與 RS-485 連接是否正常 2. 確認通訊模組串列傳輸速率與網路上其他節點的串列傳輸速率設置 一致 1. 檢查通訊模組與 RS-485 連接是否正常 2. 確認通訊模組串列傳輸速率與網路上其他節點的串列傳輸速率設置 一致 連接器 接头 传输方式 传输距离 传输速率 通讯格式 通讯协议 電氣規格 电源电压 消耗电力 绝缘电压 重量 環境規格 噪声免疫力 操作/储存环境 耐震动/冲击 标准 引脚 RS-485 6. 引脚 信号 N/C 4 D- N/C 5 GND 叙述 数据负极 参考地 6 -- N/C 引脚 信号 2 -- Stop bit: 1,2 3 D+ Parity bit: None, Odd, Even Data bit: 7,8 ASCII/RTU Modbus, User Define RJ-45 引脚 数据正极 連接器的腳位定義 Mini Dim 1 Tx+ RS-232 2 Tx- 110, 150, 300, 600, 1,200, 2,400, 4,800, 9,600, 19,200, 38,400, 57,600, 115,200 3 Rx+ Stop bit: 1,2 叙述 传输数据正极 传输数据负极 接收数据正极 4 -- Parity bit: None, Odd, Even Data bit: 7,8 ASCII/RTU 信号 3 4 5 6 引脚 信号 5 Tx 叙述 传输数据 6 -- N/C RS-485 3 -- N/C 7 -- 1,200m 4 Rx 8 GND 110, 150, 300, 600, 1,200, 2,400, 4,800, 9,600, 19,200, 38,400, 57,600, 115,200 Stop bit: 1,2 Parity bit: None, Odd, Even Data bit: 7,8 ASCII/RTU 接收数据 歐式端子台的腳位定義 3 D+ 3W 4 X2 500V 5 140g 6 X0 7 S/S 叙述 数据传输参考地 数据负极 数据正极 数字输入点 2 数字输入点 1 数字输入点 0 数字输入点参考地 8 24V +24V 9 0V 10 -- 大地 Modbus, User Define 引脚 信号 1 SG 2 D- 由欧式端子台输入 24V DC (-15% ~ 20%) ESD (IEC 61131-2, IEC 61000-4-2): 8KV Air Discharge EFT (IEC 61131-2, IEC 61000-4-4): Power Line:±2KV, Digital Input: ±2KV, Communication I/O: ±2KV RS (IEC 61131-2, IEC 61000-4-3): 80MHz ~ 1GHz, 10V/m. 1.4GHz ~ 2.0GHz, 10V/m Conducted Susceptibility Test (EN61000-4-6, IEC61131-2 9.10): 150KHz ~ 80MHz, 3V/m Surge Test (Biwave IEC61132-2, IEC61000-4-5): Power line 0.5KV DM, Ethernet 0.5KV CM, RS-485 0.5KV CM 操作:0ºC ~ 55ºC(温度)、50 ~ 95%(湿度)、污染等级 2 储存:-25ºC ~ 70ºC(温度)、5 ~ 95%(湿度) 国际标准规范 IEC61131-2, IEC68-2-6 (TEST Fc)/IEC61131-2 & IEC 68-2-27(TEST Ea) 安裝 X1 LED 燈指示說明及故障排除 POWER 燈顯示說明 LED 灯状态 显示说明 灯灭 工作电源不正常 绿灯亮 工作电源正常 LED 灯状态 灯灭 绿灯恒亮 绿灯闪烁 通訊地址開關設置 尺寸单位:mm 燈顯示說明 显示说明 无通讯或 RS-485 联机不正常 RS-485 接线不正常 RS-485 联机正常 说明 01 … F7 有效的 Modbus 通讯地址 通訊格式開關設置 代码 01 ~ F7 F1 F2 F3 F4 F5 8-N-1 9 8-N-2 2 7-O-1 A 7-O-2 3 8-O-1 B 8-O-2 01 6 7-E-1 E 7-E-2 02 7 8-E-1 F 8-E-2 03 旋钮值 波特率 (bps) 旋钮值 波特率 (bps) 1 110 7 2 150 8 9,600 10/100 Mbps Auto-Detection 3 300 9 19,200 ICMP, IP, TCP, UDP, DHCP, SMTP, MODBUS OVER TCP/IP, Delta Configuration 4 600 A 5 1,200 B 57,600 6 2,400 C 115,200 Category 5e, 100 灯状态 米 (Max) 通訊速率開關設置 F6 F7 E1 E2 E3 04 4,800 38,400 燈顯示說明 显示说明 无电源或者网络无连接 联机正常,无数据传送 传送、接收数据正常 數字顯示器顯示說明 F0 开关设置 0V 通讯模块有三个 LED 指示灯和一个数字显示器。POWER LED 用来显示 IFD9506 的工作电源是否正常; RS485 LED 与 LINK/ACT LED 用来显示 IFD9506 的通讯连接状态;数字显示器用来显示 IFD9506 通讯模块的 通讯地址、错误信息以及从站的错误信息。 RS-485 外觀 N/C 参考地 IFD9506 1 Ethernet Type II N/C N/C 7-N-2 RJ-45 with Auto MDI/MDIX -- N/C 通讯格式 8 叙述 8 連接器 N/C N/C -- 旋钮值 功能規格 N/C -- 7-N-1 9 -- 信号 通讯格式 9 7 2 0 8 接收数据负极 1 旋钮值 7 Rx- 引脚 -- 6 欧式端子台 10PIN 灯灭 绿灯亮 绿灯闪烁 通讯口 RS-485, Ethernet, RS-232 电源指示灯 通讯地址设定开关 通讯格式、通讯速率设定开关 数字显示器 RS-485 指示灯、Reset 按键、 Ethernet 指示灯 模块名称 端子台 RS-485 连接器、数字输入 点、电源输入、大地 DIN 轨连接器 叙述 5 連接器的腳位定義 RS-232 DVPACAB215 / DVPACAB230 / DVPACAB2A30 LED 2 接头 传输方式 传输电缆 传输速率 网络协议 叙述 -- LINK/ACT 1 Ethernet 信号 1 產品簡介 產品外觀 連接器的腳位定義 110, 150, 300, 600, 1,200, 2,400, 4,800, 9,600, 19,200, 38,400, 57,600, 115,200 Modbus, Delta Configuration, User Define 端子台連接器 RJ-11 RJ-11 自动侦测 10/100 Mbps 传输速率,MDI/MDI-X 自动侦测。 提供 Monitor table 可寄存监控的数据,让使用者快速存取。 支持 Modbus TCP 协议 (支持 Master 和 Slave 模式)。 经触发后发送电子邮件。 可由外部设定通讯地址、RS-485 通讯格式、波特率。 可由 Web 设定通讯参数。 4. 連接器 功能特色 0V 燈指示說明及故障排除 CRC 處理方法 簡體中文 此安装手册只提供电气规格、一般规格、安装及配线等。 配线时请务必关闭电源,请勿在上电时触摸任何端子。 本机为开放型 (OPEN TYPE) 机壳,因此使用者使用本机时,必须将其安装于具防尘、防潮及免于电击/ 冲击意外的外壳配线箱内。另必须具备保护措施(如:特殊的工具或钥匙才可打开),防止非维护人员操作 或意外冲击本体,造成危险及损坏。 3. 敘述 資料傳輸參考地 資料負極 資料正極 數位輸入點 2 數位輸入點 1 數位輸入點 0 數位輸入點參考地 LED N/C 顯示說明 掃描模組的節點位址(正常工作時) 回歸出廠設定值 開機中 工作電源電壓過低 內部錯誤,內部記憶體檢測出錯 內部錯誤,工廠製造流程出錯 網路連接錯誤 網路連線數滿 UART 設定錯誤 警報 1 觸發 警報 2 觸發 警報 3 觸發 錯誤的功能碼 錯誤的位址 錯誤的資料 接头 传输方式 传输速率 通讯格式 通讯协议 传输电缆 處理方法 1. 檢查 IFD9506 電源並確認網路線連接正常。 2. 重新上電,如果錯誤依然存在,請退回工廠進行修復。 無需處理 無需處理 注意事項 5 RS-232 代碼 接头 传输方式 传输速率 通讯格式 通讯协议 RS-232 顯示說明 無電源或者網路無連接 連線正常,無資料傳送 傳送、接收資料正常 數位顯示器顯示說明 尺寸單位:mm 燈顯示說明 RS-485 0B 显示说明 扫描模块的节点地址(正常工作时) 回归出厂设定值 开机中 工作电源电压过低 内部错误,内部存储器检测出错 内部错误,工厂制造流程出错 网络连接错误 网络联机数满 UART 设定错误 警报 1 触发 警报 2 触发 警报 3 触发 错误的功能码 错误的地址 错误的数据 CRC 错误 站台无响应 处理方法 检查 IFD9506 工作电源是否正常 无需处理 处理方法 如通讯中灯灭,检查 IFD9506 的 RS-485 确认连接正常。 确认网络上至少有一个节点可以正常通讯。 D+、D-对调。 无需处理 1. 2. 处理方法 检查 IFD9506 电源并确认网络线连接正常。 重新上电,如果错误依然存在,请退回工厂进行修复。 无需处理 无需处理 1. 2. 处理方法 无需处理 无需处理 无需处理 检查通讯模块的工作电源是否正常 1. 将通讯模块重新上电,如果错误依然存在,进行步骤 2。 2. 将通讯模块重置,如果错误依然存在,退回原厂进行修复。 1. 将扫描模块重新上电,如果错误依然存在,进行步骤 2。 2. 将通讯模块重置,如果错误依然存在,退回原厂进行修复。 确认通讯模块与网络连接正常 确认是否联机数过多 确认 RS-485, RS-232 通讯格式是否正确 查看警报输入点 1 查看警报输入点 2 查看警报输入点 3 检查 Modbus 指令是否正确 检查 Modbus 指令是否正确 检查 Modbus 指令是否正确 1. 检查通讯模块与 RS-485 连接是否正常 2. 确认通讯模块波特率与网络上其它节点的波特率设置一致 1. 检查通讯模块与 RS-485 连接是否正常 2. 确认通讯模块波特率与网络上其它节点的波特率设置一致
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Page Count : 2 Producer : GPL Ghostscript 8.15 Create Date : 2008:12:11 17:01:58 Modify Date : 2008:12:11 17:01:58 Title : 5011674901-EM01.doc Creator : PScript5.dll Version 5.2.2 Author : linda.ty.chenEXIF Metadata provided by EXIF.tools