 Electrical Specifications
5

Model

DVP10SX11R/T

Item

DVP08SM11N

DVP08SN11R/T

DVP08SP11R/T

MC

DVP16SP11R/T

1
4

Power supply voltage

MPU: 24V DC (-15% ~ 20%) (with DC input reverse polarity protection),
Expansion Unit: supplied by the MPU

Fuse

2A / 250V AC

Power Consumption

8

1W

1.5W

1.5W

Ω at 500 V DC (Between all inputs / outputs and earth)

>5M

Noise Immunity

ESD: 8KV Air Discharge
EFT: Power Line: 2KV, Digital I/O: 1KV, Analog & Communication I/O: 250V
Damped-Oscillatory Wave: Power Line: 1KV, Digital I/O: 1KV
RS: 26MHz~1GHz, 10V/m

MC

L

The diameter of grounding wire cannot be smaller than the wire diameter of terminals L and N
(All DVP units should be grounded directly to the ground pole).

Environment

Operation: 0°C ~ 55°C (temperature), 50 ~ 95% (humidity), Pollution degree 2;
Storage: -25°C ~ 70°C (temperature), 5 ~ 95% (humidity); D/A output operation: 0°C ~ 50°C
(temperature)

Vibration / Shock
Resistance

Standard: IEC61131-2, IEC 68-2-6 (TEST Fc)/IEC61131-2 & IEC 68-2-27 (TEST Ea)
64

88 / 68

3

MC
1

Grounding

138 / 133



Power supply for AC loads



Power Circuit Protection Fuse (3A)



Power On pilot indicator



Emergency stop
The machinery must provide a quick manual method
disconnecting all system power.



Circuit isolation device (System Power Disconnect)
Utilize the electromagnetic contactor and the relay to be the
isolation unit of the power circuit to prevent the possible
instability of the system when the power is supplied on and off.



DVP PLC MPU (main processing unit)



Grounding

	

Power supply:
AC: 100 ~ 240V AC, 50/60Hz
DC: 24V DC

2W

Insulation Resistance

Weight (approx.) (g)

2

G uard
Limit

-

5W

注意事項

devices, therefore the breakdown of either one device would consequently be detrimental to the whole auto
control system, and danger will thus be resulted. Please use the recommended wiring below for the power
input:

 Electrical Specifications

90 / 70

96 / 76

N
7

6

The input signal of the input point is the DC power DC input. There are two modes of DC type wiring: SINK and
SOURCE, defined as follows:

Approvals

及指令與 SA/SX/SC 系列相容,詳細說明請見 PLC 技術手冊【程式篇】,選購之周邊裝置詳細說明請見該產
品隨機手冊。
擊意外之外殼配線箱內。另必須具備保護措施(如: 特殊之工具或鑰匙才可打開)防止非維護人員操作或意
外衝擊本體,造成危險及損壞。請勿在上電時觸摸任何端子。
 交流輸入電源不可連接於輸入/出信號端,否則可能造成嚴重損壞,請在上電之前再次確認電源配線。本體上
之接地端子 務必正確的接地,可提高產品抗雜訊能力。
 本機為開放型(OPEN TYPE)機殼,因此使用者使用本機時,必須將之安裝於具防塵、防潮及免於電擊/衝

 Input Point Wiring
Sink = Current flows into the common terminal S/S

繁體中文

 本使用說明書僅提供電氣規格、功能規格、安裝配線、故障排除及周邊裝置部份說明,其它詳細之程式設計

產品簡介


謝謝您採用台達 DVP 系列可程式控制器。DVP-SX 機種為 10 點(4DI+2DO+2AI+2AO)特殊主機,除與 SA/SX/SC
主機具有相同的指令集及功能規格,並具有 2CH 的 12-bit 類比電壓/電流輸入及 2CH 的 12-bit 類比電壓/電流輸
出,同時均具有雙極性電壓/電流輸出能力。主機並內建 2 位數的七段顯示模組,直接對應內部暫存器,可用於
顯示站號或客戶自己定義的訊息代碼。


產品外觀及各部介紹

Sinkin g

Electrical Specification of Input Point

Electrical Specification of Output Point

Input Type

DC (SINK or SOURCE)

Output Type

Relay-R

Input Current

24V DC 5mA

Current
Specification

1.5A/1 point
(5A/COM)

0.3A/1 point @ 40°C; When the output of Y0
and Y1 is high-speed pulse, Y0 and Y1 =
30mA

Voltage
Specification

Below 250V
AC, 30V DC

30V DC

Active Level

Off
On,
X0,X1: above 18.5V DC
X2,X3: above 16.5V DC

→

Loop Equivalent Circuit of Input Point

75VA
(Inductive)

Maximum
Loading

90 W
(Resistive)

Responding
Time

When the output of Y0 and
Y1 is high-speed pulse, Y0
and Y1 = 0.9W (Y0 = 32kHz,
Y1 = 10kHz)

9W/1 point

About 10 ms

→
→

DVP10SX11R

24V
DC
+20%
-15%

Point
DI AI

DVP10SX11T

4
4

10

SINK
+5V

+24V

S/S

OV

S/S

X0

X1

X2

電池安裝:
電池安裝:更換電池時,請在 3 分鐘內完成,否則 PLC 內部資料(包含程式
區,萬年曆及停電保持暫存器)有可能會消失或被破壞。

24VDC

X0

Sink Type

Loop Equivalent Circuit of Input Point

Wiring Loop

Output

Type
DI

24G

DC Type
(DC Signal IN)

SINK Mode

Input

9

尺寸單位:mm

24VDC

Off On 20us Y0 and Y1 are specified
On Off 30us points for high-speed pulse

 Model Name & I/O Configuration
Power

Wiring Loop

+24V

About 10ms (An
adjustment range of 0 ~ 20
ms could be selected
through D1020 and D1021)

Model

S/S
So urcing

8

→

On Off,
X0~X3 below 8V DC
Responding
Time

Transistor-T
X0

Point
AI

DO AO

-20 ~ 20mA
2
2
DC24V/5 mA range(-1,000 ~ +1,000)
Sink or Source
-10 ~ +10V
2
range(-2,000 ~ +2,000) 2

Warning

ENGLISH

wiring, troubleshooting and peripherals. Other detail information about programming and commands is compatible
with SA/SC/SX series; please see PLC Application Manual. For more information about the optional peripheral,
please see individual product manual.
 This is an OPEN TYPE PLC. The PLC should be kept in an enclosure away from airborne dust, humidity, electric
shock risk and vibration. Also, it is equipped with protective methods such as some special tools or keys to open the
enclosure, so as to avoid the hazard to users and the damage to the PLC.
 Never connect the AC main circuit power supply to any of the input/output terminals, as it will damage the PLC.
Check all the wiring prior to power up. To avoid any electromagnetic noise, make sure the PLC is properly
grounded
. DO NOT touch terminals when power on.

+24 V

24VDC

AO

2

Relay

2

Resistor

-20 ~ 20mA
(range:-2,000 ~ +2,000)
-10 ~ +10V
(range:-2,000 ~ +2,000)

DC Type
(DC Signal IN)

17
18
19
20
21
22

24 G

SOUR CE
+5V

+24V

S/ S

OV

S/S

X0

X1

X2

24VD C

X0

Source Type

DVP-**-**-11-R

3.1 PLC Mounting Arrangements and Wiring Notes

1. There are two kinds of DVP-SX Series PLC output
modules: Relay and Transistor. For relevant electrical
specification, please refer to the function specification.
2. Be careful with the connection of the common
terminals when wiring outputs. For example, when
wiring DVP12SX11R, output terminal Y0 uses one
common terminal C0, Y1 uses C1, as shown below:

L O AD
Y0

Installation of the DIN rail:

When installing the DVP series

The DVP-PLC can be secured to a cabinet by using the

PLC, make sure that it is

DIN rail that is 35mm high with a depth of 7.5mm. When

installed in an enclosure with

mounting the PLC on the DIN rail, be sure to use the

sufficient space (as shown

end bracket to stop any side-to-side motion of the PLC,

below) to its surroundings so as

thus to reduce the chance of the wires being pulled

to allow heat dissipation.

LED

RY

Thank you for choosing DELTA’s PLC DVP series. The DVP-SX series is a 10-point (4DI+2DO+2AI+2AO)

and gently push up the clip. To remove it, pull down the

special main processing unit. Besides the same commands and functions as DVP-SA/SX/SC series, 2-CH

retaining clip and gently pull the PLC away from the DIN

12-bit analog voltage/current input and 2-CH 12-bit analog voltage/current output are all bipolar. There is

rail. As shown on the right:

P OW E R
C0

R E LAY O UT P U T

LOAD

D
D

DV P
MP

C0 Y0 C1 Y1

Y0

T
R
G

LED

D

<0.3A

Action indication: When the output point is active, the
corresponding indicator at the front will be on.
3. Isolated circuit: The optical coupler is used to isolate
signals between PLC internal circuits and input
modules.

C0

D

TRANSISTOR OUTPUT

D > 50 mm

built-in 2-digit 7-segment display corresponds to internal register directly to display PLC station or
Wiring:

 Product Profile and Outline

22-16AWG

1
2
3
4
5
6
7
8
9
Units: mm

10
11
12

13
Battery replacement: Please change the battery within 3 minutes, or the 14
internal data of the PLC (including the program area, RTC and latched
15
registers) could be lost or destroyed.
16
17
18
19
20
21
22

Status indicator: POWER, RUN,
ERROR, BAT.LOW
RUN/STOP switch
2-digital 7-segment display
Digital I/O terminal
DIN rail clip
Analog I/O terminals
I/O point indicators
COM1 (RS-232) (Rx) indicator
COM2 (RS-485) (Tx) indicator
COM1 (RS-232)
Communication port (Slave)
Nameplate
Expansion port
Mounting hold of the expansion
unit
DIN rail (35mm)
Expansion unit clip
COM2 (RS-485)
Communication port
DC Power input
2 pin removable terminal
(standard accessory)
Power input cable
(standard accessory)
Battery Cover
Battery socket connection
Battery mount

< 1.5mm

1. Please use 22-16AWG (1.5mm) wiring (either single or multiple core) for
I/O wiring terminals. The specification for the terminals is as shown on
the left. PLC terminal screws should be tightened to between 1.95
kg-cm (1.7 in-lbs). Use 60/75°C copper conductor only.
2. I/O signal wires or power supply should not run through the same
multi-wire cable or conduit.

 Analog Input/Output Point Wiring
Note 1:
Voltage input
-10V~+10V

CH0

100K
V+
I+
COM

*3

CH0

250

100K

Shielded*1
AG

3.2 Wiring Notes

Current input
-20mA~+20mA

 Power Input Wiring

24VDC OV

S/ S X0

X1

X2

V+
I+
COM

Shielded*1

*5

voltage output
-10V~+10V

AC drive, recorder,
scale valve...

AC drive, recorder,
scale valve...

CH1

250

100K
AG

CH0

shielding cable *1

current output
-20mA~20mA

20.4V~28.8V

100K

CH1
*2

DVP-SX series input power supply is DC input. Please take a note of listed items when operating DVP-SX.
Series.
1. Please make sure the power is at terminals 24V DC and 0V (power range is 20.4V DC ~ 28.8V DC). When
voltage is lower than 20.4V DC, PLC will stop operating, all outputs will turn Off and ERROR LED will flash
continuously.
2. If the power-off time is less than 10ms, the PLC still operates unaffectedly. If the power-off time is too long or
the power voltage drops, the PLC will stop operating and all the outputs will be Off. Once the power is
restored, the PLC will return to operate automatically. (There are latched auxiliary relays and registers
inside of the PLC, please be aware when programming.)

CH1

V+
I+
COM

CH0

V+
I+
COM

CH1

shielding cable *4

DC Input Type
2A

terminal of
power module

DC /DC

5V

DC24V

class 3 grounding
(100 or less)

 Safety Wiring
Since the PLC is in control of numerous devices, motion of either one device could affect the motion of other

24+
24-

DC/DC
converter



產品規格

電氣規格

機 種 DVP10SX11R/T DVP08SM11N DVP08SN11R/T DVP08SP11R/T DVP16SP11R/T
項目
電源電壓
主機:24V DC(-15% ~ 20%)(具直流輸入電源極性反接保護),擴充機:由主機供應
電源保險絲容量
2A/250V AC
消耗電力
5W
1W
1.5W
1.5W
2W
絕緣阻抗
5MΩ 以上(所有輸出/入點對地之間 500V DC)
雜訊免疫力

DVP-**-**-11-T

To secure the PLC to the DIN rail, place it onto the rail

user-defined code.



 Output Point Wiring

 Installation & Wiring

loose. At the bottom of the PLC is a small retaining clip.

 Introduction

11
12
13
14
15
16

Type
DO

SOURCE Mode

 This Instruction Sheet only provides descriptions for electrical specifications, general specifications, installation &

RUN/STOP
2
I/O
DIN

2
3
4
5
6
7

X0

S/S

電源、運行錯誤及電池低電壓
指示燈
開關
位數七段顯示模組
數位 端子
軌固定扣
類比 I/O 端子
輸出/輸入指示燈
COM1 (RS-232) 通訊接收
(Rx) 指示燈
COM2 (RS-485) 通訊傳送
(Tx) 指示燈
COM1 (RS-232) 通訊口
(Slave)
銘牌
擴充機連接口
擴充機定位孔
DIN 軌糟 (35mm)
擴充機固定扣
COM2 (RS-485) 通訊口
(Master/Slave)
電源輸入口
2 pin 脫落式端子(標準附件)
電源輸入連接線(標準附件)
電池蓋
電池插座連接
電池座

1

Source = Current flows out of common terminal S/S

+15V
AG
-15V

Please isolate analog input and other power
wiring.
Note 2:
If input signal is in current, please short out
between V+ and I+ terminals.
Note 3:
If the noise interference from loaded input wiring
terminal is significant, please connect a
capacitor with 0.1 ~ 0.47µF 25V for noise
filtering.
Note 4:
Please isolate analog output and other power
wiring.
Note 5:
If the noise interference from loaded input wiring
terminal is significant, please connect a
capacitor with 0.1 ~ 0.47µF 25V for noise
filtering.
Note 6:
Please connect
power module terminal and
analog output module terminal to system
earth point and make system earth point be
grounded or connects to machine cover.
Warning:
DO NOT wire to the No function terminal

接地
操作/儲存環境
耐振動/衝擊
重量(約, g)
認證

ESD: 8KV Air Discharge
EFT: Power Line: 2KV, Digital I/O: 1KV, Analog & Communication I/O: 250V
Damped-Oscillatory Wave: Power Line: 1KV, Digital I/O: 1KV
RS: 26MHz ~ 1GHz, 10V/m

接地配線之線徑不得小於電源端 L,N 之線徑(多台 PLC 同時使用時,請務必單點接地)
操作:0°C ~ 55°C(溫度),50 ~ 95%(濕度);污染等級 2
儲存:-25°C ~ 70°C(溫度),5 ~ 95%(濕度);D/A 輸出操作:0°C ~ 50°C(溫度)
國際標準規範 IEC61131-2, IEC68-2-6 (TEST Fc)/IEC61131-2 & IEC68-2-27 (TEST Ea)
138 / 133

64

輸入點電氣規格
輸 入 直流(SINK 或 SOURCE)
形式
輸入
24V DC 5mA
電流
Off → On,

動作
位準

X0
X2

、X1 為 18.5V DC 以上
、X3 為 16.5V DC 以上

On → Off,
X0~X3 8V DC

為

輸出
形式
電流
規格
電壓
規格
最大
負載

以下

反 應 約 10ms(由 D1020 及 D1021 可
時間
作 0 ~ 20ms 的調整)
反應
時間


機種型號與 I/O 配置
機種

DVP10SX11R
DVP10SX11T

24VDC
+20%
-15%

4

2

4

2

電晶體-T
點 @ 40°C
點(5A/COM) 0.3A/1
高速脈波輸出時, Y0、Y1 為 30mA

250V AC,30V DC

以下

(電感性)
90W(電阻性)
約 10 ms

30V DC

75VA

DI

9W/1

或

點

Off → On 20us
On → Off 30us

高速脈波輸出時
Y0、Y1 為 0.9W
(Y0:50KHz,Y1:10KHz)
Y0、Y1 輸出為
高速脈波輸出點
輸出單元
形式

點數
AI
-20 ~ 20mA

DC24V/5 mA (
Sink Source
(

96 / 76

輸出點電氣規格

繼電器-R
1.5A/1

90 / 70

輸入單元
形式

電源 點數
DI AI

88 / 68

範圍:-1,000 ~ +1,000)
-10 ~ +10V
範圍:-2,000 ~ +2,000)

DO AO
2

2

2

2

DO

AO

~ 20mA
繼電器 (範圍:-20-2,000
~ +2,000)
~ +10V
電晶體 (範圍:-10-2,000
~ +2,000)

安裝及配線


3.1



盤內安裝及配線

輸出點之配線
DVP-**-**-11-R

鋁軌之安裝方法:
鋁軌之安裝方法:
適合 35mm 之 DIN 鋁軌,主機欲
掛於鋁軌時,先將 PLC 下方之固
定塑膠片壓入,再將 PLC 由上方
掛上再往下壓即可。欲取下 PLC
時,PLC 底部下之固定塑膠片,以
起子插入凹槽,向上撐開即可,該
固定機構塑膠片為保持型,當所有
的固定片撐開後,再將 PLC 往上
外方取出,如右圖所示:
配線:
配線:

Y0

在安裝時,請裝配於封閉式之控制箱內,
其周圍應保持一定之空間(如下圖所示),以
確保 PLC 散熱功能正常。

DIN

LED

1.

LOAD

D

DV P
MP

輸出/入配線端請使用 22-16AWG (1.5mm)單蕊祼線或多蕊線,端子規
格如左所示。PLC 端子鏍絲扭力為 1.95kg-cm (1.7 in-lbs)。只能使用
60/75°C 的銅導線。
2. 在配線時請勿請輸入點信號線與輸出點或電源等動力線置於同一線糟
內。



類比輸入/輸出點之配線
電壓輸入

-1 0V~+10 V

*2

隔離線*1

S/S

X0

X1

10 0K

電壓輸出

*5

X2

變頻器、記錄器
比例閥 ...

5V

-10V~+10V

CH0
CH0

V+
I+
COM

隔離線*1

CH1

隔離線*4

DC24V

由於 PLC 控制許多裝置,任一裝置的動作可能都會影響其它裝置的動作,因此任一裝置的故障都可能會造成整個
自動控制系統失控,甚至造成危險。所以在電源端輸入回路(DVPPS01/DVPPS02),建議配置如下的保護回路:



MC
1



4



8
2

MC
1





N
7

	



CH 1

25 0

AG

接至電源模
組之 端

6

10 0K
V+
I+
COM

電流輸出

安全配線回路

3

10 0K

CH1

-20mA~ +20mA

-20mA~20mA

2A

Guard
Limit

CH 0

25 0

AG

電流輸入

20.4V~ 28.8 V

DC/DC

L

V+
I+
COM

隔離線*1

5

10 0K

CH0
*3

機種為直流電源輸入,在使用上應注意下列事項:
電源請接於 24V DC 及 0V 兩端,電源範圍為 20.4V DC ~ 28.8V DC,當電源電壓低於 20.4V DC 時,PLC 會停
止運轉,輸出全部 Off,ERROR LED 快速閃爍。
當停電時間低於 10ms 時,PLC 不受影響繼續運轉,當停電時間過長或電源電壓下降將使 PLC 停止運轉,輸
出全部 Off,當電源恢復正常時,PLC 亦自動回復運轉。(PLC 內部具有停電保持的輔助繼電器及暫存器,使
用者在作程式設計規劃時應特別注意使用)

MC

電晶體

1.

24 VDC OV

輸入點之配線

交流電源負載
電源回路保護用保險絲 (3A)
電源指示燈
緊急停止
為預防突發狀況發生,設置一緊急停止按鈕,可在狀況
發生時,切斷系統電源。
系統回路隔離裝置
使用電磁接觸器、繼電器等開關作為系統電源回路隔離
裝置,可防止電源斷續供應時,造成系統的不穩定。
DVPPS01/DVPPS02 本體
接地
電源供應:
交流 (AC):100 ~ 240V AC, 50/60Hz
直流 (DC):24V DC

輸入點之入力信號為直流電源 DC 輸入,DC 型式共有兩種模式接法:SINK 及 SOURCE,其定義如下:
Sink = 電流流入共用端 S/S
Source = 電流流出共用端 S/S

V+
I+
COM

CH1

3.

註 1:
類比輸入請與其他電源線隔離。
註 2:
如果連接電流信號時,V+ 及 I+ 端子請務必
短路。
註 3:
如果輸入電壓有漣波造成配線受雜訊干擾時
請連接 0.1 ~ 0.47 µF 25V 之電容。
註 4:
類比輸出請與其他電源線隔離。
註 5:
如果負載之輸出端漣波太大造成配線受雜訊
干擾時,請連接 0.1 ~ 0.47μF 25V 之電容。
註 6:
請將主機之 端連接到系統接地點,再將系
統接點作第三種接地或接到配電箱之機殼上。

24+
24 -

DC/DC

轉換器

+15V
AG
-15V

直流形式
(DC Signal IN)

注意事項

简体中文

 本使用说明书仅提供电气规格、功能规格、安装配线、故障排除及周边装置部份说明,其它详细之程序设计

及指令与 SA/SX/SC 系列兼容,详细说明请见 PLC 技术手册【程序篇】,选购之周边装置详细说明请见该产
品随机手册。
 本机为开放型(OPEN TYPE)机壳,因此使用者使用本机时,必须将之安装于具防尘、防潮及免于电击/冲
击意外之外壳配线箱内。另必须具备保护措施(如: 特殊之工具或钥匙才可打开)防止非维护人员操作或意
外冲击本体,造成危险及损坏。请勿在上电时触摸任何端子。
 交流输入电源不可连接于输入/出信号端,否则可能造成严重损坏,请在上电之前再次确认电源配线。本体上
之接地端子 务必正确的接地,可提高产品抗噪声能力。

產品簡介


谢谢您采用台达 DVP 系列可编程序控制器。DVP-SX 机种为 10 点(4DI+2DO+2AI+2AO)特殊主机,除与 SA/SX/SC
主机具有相同的指令集及功能规格,并具有 2CH 的 12-bit 模拟电压/电流输入及 2CH 的 12-bit 模拟电压/电流输
出,同时均具有双极性电压/电流输出能力。主机并内建 2 位数的七段显示模块,直接对应内部寄存器,可用于
显示站号或客户自己定义的信息代码。

2
3
4
5
6
7

配線回路

9

尺寸单位:mm

10

安装:
安装:更换电池时,请在 3 分钟内完成,否则 PLC 内部数据(包含程序区,
万年历及停电保持寄存器)有可能会消失或被破坏。

11
12
13
14
15

+5V

+24V

X0

SINK

8

SINK

模式

OV

S/S

X0

X1

X2

24V DC
Sink Ty pe

輸入點回路等效電路

配線回路

16

直流形式
(DC Signal IN)

+24 V

24 G

19
X0

模式

18

SOUR CE
+5V

S/ S

SOURCE

17

24VDC

+24V

OV

S/S

X0

X1

X2

24 VDC
Sourc e Ty pe

MC

2W

为 18.5V DC 以上
为 16.5V DC 以上

On → Off,
X0~X3
8V DC

以下

电源

DVP10SX11R

24V DC
+20%
-15%



N
7

6

	

 输入点之配线
96 / 76

输入点之入力信号为直流电源 DC 输入,DC 型式共有两种模式接法:SINK 及 SOURCE,其定义如下:
Sink = 电流流入共享端 S/S
Source = 电流流出共享端 S/S
S/S

X0

Sinking

晶体管-T
0.3A/1 点 @ 40°C
高速脉冲输出时, Y0、Y1 为 30mA

S/S
Sourcing

X0

30V DC

75VA

 机种型号与 I/O 配置

机种

90 / 70

以下

(電感性)
90W(電阻性)
約 10 ms

最大
负载
反应 约 10ms(由 D1020 及 D1021 可
反应
作 0 ~ 20ms 的调整)
时间
时间
为

點(5A/COM)

250V AC,30V DC

9W/1



MC


L

输出点电气规格

繼電器-R
1.5A/1

3

1

高速脉冲输出时 、 为
: , :

点

Y0 Y1
0.9W(Y0 50KHz Y1 10KHz)
Y0、Y1 输出为
高速脉冲输出点

Off → On 20us
On → Off 30us

输入点回路等效电路

配线回路

+2 4V

直流形式

24V D C
24 G

(DC Signal IN)

SINK
+5V

+24V

S/ S

点数
4

2

4

2

DI

点数
AI

DO AO

-20 ~ 20mA

DC24V/5 mA
Sink Source

或

输出单元
形式

(范围:-1,000 ~ +1,000) 2
-10 ~ +10V
(范围:-2,000 ~ +2,000) 2

2
2

DO

输入点回路等效电路

AO

-20 ~ 20mA
继电器 (范围:
-2,000~ +2,000 )
-10 ~ +10V
晶体管 (范围:
-2,000~ +2,000 )

20
21
22

电源、运行错误及电池低电
压指示灯
RUN/STOP 开关
2 位数七段显示模块
数字 I/O 端子
DIN 轨固定扣
模拟 I/O 端子
输出/输入指示灯
COM1 (RS-232) 通信接收
(Rx) 指示灯
COM2 (RS-485) 通信传送
(Tx) 指示灯
COM1 (RS-232) 通讯口
(Slave)
铭牌
扩展连接口
扩展定位孔
DIN 轨糟 (35mm)
扩展固定扣
COM2 (RS-485) 通讯口
(Slave)
电源输入口
2 pin 脫落式端子
(标准附件)
电源输入连接线(标准附件)
电池盖
电池插座连接
电池座

安裝及配線



直流形式

24 G

S OUR CE
+5 V

+24V

模式

< 1.5mm

1.

2.

POWER
C0

2.

2.

LOAD

D

DV P
MP

D

Y0

T
R
G

LE D

<0.3A

系列 PLC 输出模块共有二种:继电
器及晶体管,其相关电气规格请参考功能规
格部份。
输出端在实际配线时,应特别注意共享端的
连接,以 DVP10SX11R 为例,输出端 Y0
用一个 C0 共同端,另外 Y1 用 C1,如图所

输出/入配线端请使用 22-16 AWG (1.5mm) 单蕊祼线或多蕊线,端子规格
如左所示。PLC 端子镙丝扭力为 1.95kg-cm (1.7 in-lbs)。只能使用 60/75°C
铜导线。
在配线时请勿请输入点信号线与输出点或电源等动力线置于同一线糟内。

TRANSIS TOR OUTPUT

晶体管
 模拟输入/输出点之配线
电压输入

-10V~+10V

CH0
*3

隔离线*1

100K
V+
I+
COM

CH0

250
100K
AG

电流输入

CH1
*2

-2 0mA~+2 0mA

隔离线*1

100K
V+
I+
COM

CH1

250
100K
AG

电压输出

*5

-10V~+10V

CH0

隔离线*1

V+
I+
COM

CH0

V+
I+
COM

CH1

电流输出

20 .4V ~2 8.8 V

-2 0mA~20mA
24VDC OV

S/ S

X0

X1

DC/DC

CH1

X2

2A
5V

变频器、记录器
比例阀...
接至电源模
块之 端

由于 PLC 控制许多装置,任一装置的动作可能都会影响其它装置的动作,因此任一装置的故障都可能会造成整个
自动控制系统失控,甚至造成危险。所以在电源端输入回路(DVPPS01/DVPPS02),建议配置如下的保护回路:

隔离线*4

DC2 4V

第三种接地
(接地阻抗Ω以下)

24+
24 -

DC/DC

转换器

示:
动作指示:
当输出点动作时,正面的该点指示灯亮。
隔离回路:PLC 内部回路与输入模块之间
使用光耦合器作信号隔离。
C0 Y0 C1 Y1

C0

D

变频器、记录器
比例阀...

 安全配线回路

X2

DVP-**-**-11-T

机种为直流电源输入,在使用上应注意下列事项:
电源请接于 24V DC 及 0V 两端,电源范围为 20.4V DC ~ 28.8V DC,当电源电压低于 20.4V DC 时,PLC 会停
止运行,输出全部 Off,ERROR LED 快速闪烁。
当停电时间低于 10ms 时,PLC 不受影响继续运转,当停电时间过长或电源电压下降将使 PLC 停止运行,输
出全部 Off,当电源恢复正常时,PLC 亦自动回复运行。(PLC 内部具有停电保持的辅助继电器及寄存器,使
用者在作程序设计规划时应特别注意使用)
直流电源
输入型式

X1

D

 电源端输入配线
1.

继电器

RELAY OUTPUT

3.2 注意事项
SX

X0

1. DVP-S
Y0

RY

D > 50 mm

22-16AWG

S/S

Source Type

LOAD

配线:

OV

24VDC

X0

DVP-**-**-11-R

PLC 在安装时,请装配于封闭式之控制箱
内,其周围应保持一定之空间(如下图所
示),以确保 PLC 散热功能正常。

X2

配线回路

 输出点之配线

铝轨之安装方法:
铝轨之安装方法:
适合 35mm 之 DIN 铝轨,主机欲挂于铝轨
时,先将 PLC 下方之固定塑料片压入,再
将 PLC 由上方挂上再往下压即可。欲取下
PLC 时,PLC 底部下之固定塑料片,以起
子插入凹槽,向上撑开即可,该固定机构
塑料片为保持型,当所有的固定片撑开后,
再将 PLC 往上外方取出,如右图所示:

X1

24V D C

3.1 盘内安装及配线
DIN

X0

+ 24V

(DC Signal IN)

LED

S/S

Sink Ty pe

模式

SINK

OV

24 V DC

X0

输入单元
形式

SOURCE

+24V

S/S

输出
形式
电流
规格
电压
规格

88 / 68

2

Guard
Limit

第三種接地
接地阻抗 以下 )

1

24G

64

Off → On,

X0, X1
X2, X3

DVP10SX11T

 产品外观及各部介绍

24VDC

138 / 133

24V DC 5mA

动作
位准



8

接地配线之线径不得小于电源端 L,N 之线径(多台 PLC 同时使用时,请务必单点接地)
操作:0°C ~ 55°C(温度),50 ~ 95%(湿度);污染等级 2
储存:-25°C ~ 70°C(温度),5 ~ 95%(湿度);D/A 輸出操作:0°C ~ 50°C(溫度)
国际标准规范 IEC61131-2, IEC68-2-6 (TEST Fc)/IEC61131-2 & IEC68-2-27 (TEST Ea)

输入点电气规格
直流(SINK 或 SOURCE)

输入
形式
输入
电流

DVP16SP11R/T

(

S/S
Sourcing

輸入點回路等效電路

接地
操作/储存环境
耐振动/冲击
重 量(约, g)
认证



1

S/S

Sinking

X0

噪声免疫力


MC
4

ESD: 8KV Air Discharge
EFT: Power Line: 2KV, Digital I/O: 1KV, Analog & Communication I/O: 250V
Damped-Oscillatory Wave: Power Line: 1KV, Digital I/O: 1KV
RS: 26MHz~1GHz, 10V/m

DI AI

注意:
注意:空端子 請勿配線。

X0

S/S

机 种 DVP10SX11R/T DVP08SM11N DVP08SN11R/T DVP08SP11R/T
项目
主机:24V DC(-15% ~ 20%)(具直流输入电源极性反接保护),扩展:由主机供应
电源电压
电源保险丝容量 2A / 250V AC
消耗电力
5W
1W
1.5W
1.5W
绝缘阻抗
5MΩ 以上(所有输出 /入点对地之间 500V DC)

示:
動作指示:
當輸出點動作時,正面的該點指示燈亮。
隔離回路:PLC 內部回路與輸入模組之間
使用光耦合器作信號隔離。

交流电源负载
电源回路保护用保险丝 (3A)
电源指示灯
紧急停止
为预防突发状况发生,设置紧急停止按钮,可在状况发
生时,切断系统电源。
系统回路隔离装置
使用电磁接触器、继电器等开关作为系统电源回路隔离
装置,可防止电源断续供应时,造成系统的不稳定。
DVPPS01/DVPPS02 本体
接地
电源供应:
交流(AC):100 ~ 240V AC, 50/60Hz
直流(DC):24V DC


5

 电气规格

C0 Y0 C1 Y1

< 0. 3A

C0

TRANSISTOR OUTPUT

變頻器、記錄器
比例閥 ...



Y0

T
R
G

LED

D > 50 mm

注意事項
電源端輸入配線

直流電源
輸入型式

繼電器

RELAY OUTPUT

產品規格



DV P-* *-**-11-T

3.2

2.

2.

D

< 1.5mm

SX

POWER
C0

D

22-16AWG



RY

PLC

D

系列 PLC 輸出模組共有二種:繼電
器及電晶體,其相關電氣規格請參考功能規
格部份。
輸出端在實際配線時,應特別注意共用端的
連接,以 DVP10SX11R 為例,輸出端 Y0
用一個 C0 共同端,另外 Y1 用 C1,如圖所

1. DVP-S
LOAD

+1 5V
AG
-15 V

3.

注 1:
模拟输入请与其它电源线隔离。
注 2:
如果连接电流信号时,V+ 及 I+ 端子请务必
短路。
注 3:
如果输入电压有涟波造成配线受噪声干扰时
请连接 0.1 ~ 0.47 µF 25V 之电容。
注 4:
模拟输出请与其它电源线隔离。
注 5:
如果负载之输出端涟波太大造成配线受噪声
干扰时,请连接 0.1 ~ 0.47µF 25V 之电容。
注 6:
请将主机之 端连接到系统接地点,再将系
统接点作第三种接地或接到配电箱之机壳上。
注意:
注意:空端子 请勿配线。



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Count                      : 2
Producer                        : GPL Ghostscript 8.15
Create Date                     : 2007:09:11 13:47:31
Modify Date                     : 2007:09:11 13:47:31
Title                           : 5011666801-DX01.doc
Creator                         : PScript5.dll Version 5.2
Author                          : LINDA.TY.CHEN
EXIF Metadata provided by EXIF.tools

Navigation menu