Program Transfer Module DVP-PCC01 PCC01-Instruction Sheet-English-20060310
2015-01-24
: Delta-Electronics Delta-Electronics-Program-Transfer-Module-Dvp-Pcc01-Users-Manual-338823 delta-electronics-program-transfer-module-dvp-pcc01-users-manual-338823 delta-electronics pdf
Open the PDF directly: View PDF .
Page Count: 1
Download | ![]() |
Open PDF In Browser | View PDF |
2006-03-10 3.2 Password Function The PCC01 transfer module can obtain a password from the source PLC along with the program. When the program is transferred from the ACPGMXFER to the destination PLC it will compare the password and if the 5011641001-PCE1 http://www.delta.com.tw/industrialautomation/ password in the PLC matches or no password was previously set the transfer will complete. This will require future ACPGMXFER transfers to a password protected PLC to have the same password as the PLC, Also if a DVP-PCC01 password is set via the transfer module any WPLSOFT users will be required to enter the password before any Instruction Sheet program changes can be made. The password is entered into registers D1086 and D1087 and set on by enabling M1086. These addresses Program Transfer Module programmer to enter the password into registers D1086 and D1087. Enter the value in Hexadecimal format, a 2 D1087. Refer to the table in section 6 for cross reference of valid ASCII characters. Next set M1086 on to make this password active. Introduction 30 sec. 35 sec. DVP-SA/SX/SC 1 min. 10 sec. 1 min. 15 sec. 1 min. 5 sec. 1 min. 10 sec. DVP-EH/SV 2 min. 50 sec. 3 min. 1 min. 10 sec. 1 min. 20 sec. 4 COM. It provides rapidly and safely data transmission to PLC. the destination PLC with the switch set to the “write” position. The transfer module will download the program Applicable Models and Read/Write Device Types: and set the password to 1234. Program area PCC01 will show an error or warning status with the ERR and OK LEDs. Program (Steps) D register M device File register 4K D0~D599 M0~M1279 N/A DVP-SA/SX/SC 8K D0~D4999 M0~M4095 1600 DVP-EH/SV 16K D0~D9999 M0~M4095 10000 Example as follows: Password Key 5 300 ASCII code (HEX) 3 3.3 Indicator PCC01 Internal memory error DVP-PCC01 ERA SE D1087 High byte Low byte High byte Low byte Byte 1 Byte 2 Byte 3 Byte 4 1 (0x31=H31) 2 (0x32=H32) 3 (0x33=H33) 4 (0x34=H34) Read PCC01 33 RUN On Off Recommend PCC01 hardware may be damaged, please replace it. Make sure PCC01 model record is compatible with PLC model. Incompatible model Off Operation error – unable to write PCC01 doesn’t contain a valid program for “WR” mode. PCC01 in “WR” mode, and PLC is in RUN mode. Please place PLC in STOP mode. Communication protocol error! Please confirm the PLC is in STOP mode and reboot the PLC. Synchronous blinking Check PLC program syntax. Operation error – unable to read Cross blinking PLC protect with password. Communication protocol error! Please confirm PLC in STOP mode and remove/apply power to. On Blinking PCC01 is in “RD” mode, and is protected by password. Please push erase button when PCC01 connect to the PLC. For more detailed operation of erasure, please reference to section 3.4. PCC01 is in “WR” mode, and PLC is protected by password. Please disable the password in PLC, or set the same PLC’s password in the PCC01. For more detailed operation , please reference to section 3.2. Off On Password verify error Write ERASE completed Please refer to section 3.5. w/ PW w/o PW w/ PW w/o PW Able to read Password verify error Unable to write Unable to write w/ PW Unable to read Unable to read Unable to write Unable to write Able to write Able to write and write password to PLC If ERR LED is always ON or blinking. Please refer to section 4. Password verify error Able to write after verification results: w/o PW 4 Able to read Password verify error STOP w/ PW Unit: mm OK w/o PW PLC Status 66.3 ERR The conditions when PCC01 will read/write to an PLC:(w/ PW: with password; w/o PW: without password) RD ER R OK C OM POWE R WR 6 D1086 Password setting Product Profile 2 Below is the summary: The password key has four digits. Each digit is 8bits number and form with ASCII in D1086 and D1087. PLC device area 1 Error Indication Blinking password of 1234. The destination PLC will have to be in the stop mode, next connect the transfer module to Unable to read Unable to read 5 Troubleshooting Disconnecting the PCC01 or powering down the PLC when the operation in progress will cause unexpected PCC01 in “RD” mode: 1. Power LED 4. Error LED 2. Communication Indicator LED 5. Operation mode: read/write functional switch 3. Operation completed LED 6. PCC01 Data Erase button Specification 3.4 PCC01 data will be invalid. Please reboot the PLC again or re-connect PCC01 to PLC. PCC01 force PLC in RUN/STOP status PCC01 in “WR” mode: PCC01 provide Run/Stop function in DVP-ES/EX/EC series MPUs. When PCC01 ERR and OK LEDs are blinking PLC program will be invalid. Please reboot PLC again or re-connect the PCC01 to PLC. simultaneously in WR mode and PLC is in RUN status, user can press the ERASE button within 30 seconds to force PLC in STOP After that, disconnect PCC01 from the PLC and then connect to PLC again. Once data write-in is Data Retention 10 years Write Cycles At Least 10,000 times Transmission speed 9600 /19200 bps (PB: 9600 bps only) Storage -25℃~70℃ (Temperature), 5~95% (Humidity) Operation 0℃~55℃ (Temperature), 50~95% (Humidity), Pollution degree 2 Once PCC01 connects to PLC, please press and hold the ERASE button within 5 secs. Continue to hold the button until the OK LED turns on. Release the button and the ACPGMXFER module can now be removed. Noise Immunity ESD: ±4KV Air Discharge EFT: Power Line: 2KV RS: 0.15MHz~80MHz, 10V/m Surge : ±1KV completed, push ERASE within 30 seconds while PCC01’s OK LED is ON to switch PLC status from STOP to RUN. 3.5 3.6 International Standard: IEC1131-2, IEC 68-2-6(TEST Fc) IEC1131-2 & IEC 68-2-27 (TEST Ea) 3 Operation and Function Description PCC01 Data Erase function: Data Duplication Function (PLC←PCC01) WR (Write) 1 Set RD/WR switch to “RD” mode Set RD/WR switch to “WR” mode and confirm PLC is STOP status 2 Connect PCC01 to PLC COM1.Reading will start after 5sec. waiting. Set RD/WR switch to “WR” mode and place the PLC RUN/STOP switch in the STOP position. 3 After reading data from PLC, “OK” LED will light Connect PCC01 to PLC COM1.Writing will start after 5 sec. 4 Disconnect PCC01 when read process is done. Disconnect PCC01 when write process is done. 3.7 Appendix: ASCII Table The password composed of 4 bytes. Each byte is an ASCII character of ‘0’~’9’, ‘A’~’Z’. ‘a’ ~’z’. The password is case sensitive. Below is ASCII table. HEX 0 1 2 3 4 5 6 7 8 9 A B C D E F ASCII ⌧ ⌧ ⌧ ⌧ ⌧ ⌧ ⌧ ⌧ ⌧ ⌧ ⌧ ⌧ ⌧ ⌧ ⌧ ⌧ 1F HEX 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E ASCII ⌧ ⌧ ⌧ ⌧ ⌧ ⌧ ⌧ ⌧ ⌧ ⌧ ⌧ ⌧ ⌧ ⌧ ⌧ ⌧ HEX 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F Besides program transfer, the PCC01 can also read/write register and coil data to/from the PLC. The PCC01 ASCII SP ! " # $ % & ' ( ) * + , - . / HEX 30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F write the data depending on the operation selected. If M1085 is ON he PCC01 will not read or write the data. ASCII 0 1 2 3 4 5 6 7 8 9 : ; < = > ? HEX 40 41 42 43 44 45 46 47 48 49 4A 4B 4C 4D 4E 4F 1.) Set M1085 On/Off in PLC (PLC→PCC01) RD (Read) 6 will monitor coil M1085 to see if it should read/write the data. When M1085 is OFF, the PCC01 will read or Data Duplication steps: 3.1 Read/Write Operation Sequence: Step 45 sec. Connect the transfer module to the source PLC with the switch set to read. This will upload the program and the PCC01 can read or write PLC programs, devices (coils and registers) and passwords to all series of PLC via Vibration / Shock Resistance 35 sec. password of 1234 would be entered as follows. H3132 into register D1086 followed by H3334 into register Do not change the RD/WR switch during PCC01 operation. DVP-ES/EX/EC/SS Write DVP-ES/EX/SS Error Message The password is set in the source PLC by using the Batch Monitoring feature of the PLC software or hand held Do not disconnect PCC01 before Transmission ends; otherwise, it may cause data loss in the PCC01 Models Read M1086 is not set on the passwords will be ignored. Please set the RD/WR switch before operating the . Device type Write the unit will be password protected and registers D1086 and D1087 will not be populated with the password. If Warning M1085=ON Read serve only as an entry point for the password at the source PLC. When the file is ‘Wrote’ to the destination PLC 1 M1085=OFF Model ASCII @ A B C D E F G H I J K L M N O HEX 50 51 52 53 54 55 56 57 58 59 5A 5B 5C 5D 5E 5F 2.) Select PCC01 RD/WR switch in reading or writing mode. ASCII P Q R S T U V W X Y Z ⌧ ⌧ ⌧ ⌧ ⌧ 3.) Connect PCC01 to PLC COM1 communication port HEX 60 61 62 63 64 65 66 67 68 69 6A 6B 6C 6D 6E 6F 4.) After operation is completed, “OK” LED will turn on. ASCII ` a b C d e f g h i j k l M n o 5.) Disconnect PCC01 from the PLC. HEX 70 71 72 73 74 75 76 77 78 79 7A 7B 7C 7D 7E 7F ASCII p q r s t u v w x y z { | } ~ ⌧ Estimation of Read/Write Operating Timing Note: ‘⌧’:Denotes invalid ASCII character, do not use.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes XMP Toolkit : 3.1-701 Producer : Acrobat Distiller 7.0 (Windows) Create Date : 2006:03:17 14:46:54+08:00 Creator Tool : PScript5.dll Version 5.2 Modify Date : 2006:03:17 14:46:54+08:00 Format : application/pdf Creator : lauren.hsu Title : Microsoft Word - 5011641001_031706.doc Document ID : uuid:e82b4d19-8375-4796-83f2-4a999e102939 Instance ID : uuid:11eb48d8-f605-44f2-9bdc-cff5c32857e9 Page Count : 1 Author : lauren.hsuEXIF Metadata provided by EXIF.tools