DVP28SV11T Power supply voltage 24V DC (-15% ~ 20%) (with counter-connection protection on the polarity of DC input power) Inrush current Max. 2.2A@24V DC Power consumption 6W Since DVP28SV is only compatible with DC power supply, Delta power supply modules (DVPPS01/DVPPS02) are suitable power supplies for DVP28SV. Users are suggested to install the protection circuit at the power supply terminal to protect DVPPS01 or DVPPS02. AC power supply load 5 MC 1 Power circuit protection fuse (3A ) 4 > 5MΩ (all I/O point-to-ground: 500V DC) ESD (IEC 61131-2, IEC 61000-4-2): 8KV Air Discharge EFT (IEC 61131-2, IEC 61000-4-4): Power Line: 2KV; Digital I/O: 1KV, Analog & Communication I/O: 1KV Damped-Oscillatory Wave: Power Line: 1KV, Digital I/O: 1KV RS (IEC 61131-2, IEC 61000-4-3): 26MHz ~ 1GHz, 10V/m The diameter of grounding wire shall not be less than that of the wiring terminal of the power. (When many PLCs are in use at the same time, please make sure every PLC is properly Earth grounded.) Operation: 0ºC ~ 55ºC (temperature); 50 ~ 95% (humidity); pollution degree 2 Operation/storage Storage: -40ºC ~ 70ºC (temperature); 5 ~ 95% (humidity) International standards: IEC61131-2, IEC 68-2-6 (TEST Fc)/IEC61131-2 & IEC 68-2-27 Vibration/shock immunity (TEST Ea) 260g 240g Weight (g) Insulation resistance 8 2 Guard Limit Noise immunity Type Input point Current DC (Sink or Source) Motion level X0 ~ X7,X12 ~ X13,X16 ~ X17 OffOn > 16.5VDC 24VDC 5mA Responding time X10 ~ X11,X14 ~ X15 X0 ~ X17 OffOn OnOff > 18.5VDC < 8VDC Approx. 10 ms (can be adjusted within the range of 10 ~ 60 ms by D1020 and D1021) MC 3 MC Power indicator System circuit isolation device The device is made of electromagnetic contactor and relay as the switch to prevent the instability of system when the power is intermittently supplied. DVPPS01/DVPPS02 (main processing unit) 1 L 7 N 6 Emergency stop This button can cut off the system power supply when accidental emergency takes place. Earth Power supply AC: 100 ~ 240V AC, 50/60Hz Input point wiring There are two types of DC inputs, SINK and SOURCE. DC Signal IN Input point loop equivalent circuit S/S Wiring loop 詳細說明請見 DVP-PLC 應用技術手冊【程式篇】,選購之週邊裝置詳細說明請見該產品隨機手冊或 DVP-PLC 應用技術手冊【特殊模組篇】。 (OPEN TYPE) 機殼,因此使用者使用本機時,必須將之安裝於具防塵、防潮及免於電擊/衝擊 意外之外殼配線箱內。另必須具備保護措施(如:特殊之工具或鑰匙才可打開)防止非維護人員操作或意外 衝擊本體,造成危險及損壞。 交流輸入電源不可連接於輸入/出信號端,否則可能造成嚴重損壞,請在上電之前再次確認電源配線。請勿 在上電時觸摸任何端子。本體上之接地端子 務必正確的接地,可提高產品抗雜訊能力。 本機為開放型 產品簡介 謝謝您採用台達 DVP 系列可程式控制器。SV 為 28 點(16 輸入點 + 12 輸出點)PLC 主機,提供豐富的指令集, 並具有 16K Steps 的程式記憶體,可連接 SS/SA/SX/SC/SV 全系列擴充機,包含數位輸入/輸出(最大輸入/輸出擴 充點數可達 512 點)、類比模組(A/D、D/A 轉換及溫度單元) 及新型高速擴充機等各類機型。四組高速(200KHz) 脈波輸出、新增兩軸補間指令,可滿足各種應用場合,並且體積小,安裝容易。 產品外觀及各部介紹 SINK +24V Sinking 24VDC 繁體中文 本使用說明書僅提供電氣規格、功能規格、安裝配線部份說明,其它詳細之程式設計及指令與 EH 系列相容, 70 +5V 24G X0 relay-R Output point Current 1.5A/1 point (5A/COM) General: 0.3A/1 point @40ºC High-speed: < transist 1KHz, 0.3A/1 point @ 40ºC; ≥1KHz, or-T 30mA/1point@40 ºC Voltage Max. loading 250VAC, > 30VDC 75VA (inductive) 90 W (resistive) Responding time Mechanical life Approx. 10 ms 2×10 times (without load) 7 OffOn 20us OnOff 30us OffOn 0.2us OnOff 0.2us Max. 10KHz for Y5, Y7, Y10 ~ Y13 30VDC Max. 200KHz for Y0, Y1, Y2, Y3, Y4, Y6 Input Point Type Type DC (Sink 24VDC 12 Or Source) DVP28SV11T Transistor X15 X16 X17 Warning ENGLISH This Instruction Sheet only provides descriptions for electrical specifications, general specifications, installation & wiring. Other detail infromation about programming and intructions is compatible with EH series; please see PLC Application Manual. For more information about the optional peripherals, please see individual product instuction shee or “DVP-PLC Application Manual: Special module”. This is an OPEN TYPE PLC. The PLC should be kept in an enclosure away from airborne dust, humidity, electric shock risk and vibration. Also, it is equipped with protective methods such as some special tools or keys to open the enclosure, in order to prevent hazard to users or damage the PLC. Do NOT connect the AC main circuit power supply to any of the input/output terminals, or it may damage the PLC. Check all the wiring prior to power up. To prevent any electromagnetic noise, make sure the PLC is properly grounded . Do NOT touch terminals when power on. 20 2 X 15 X 16 X 17 C4 Y 10 Y 11 Y 12 Y 13 90 109.4 101 PLC 1 DVP-**-**-11-T Y0 POWER RY 90 3 21 10 60 D 12 15 13 16 14 17 18 Unit: mm POWER/RUN/BAT.LOW/ERROR indicator 12 Extension module connection port 2 COM1(RS-232) receiving communication (Rx) indicator 13 DIN rail (35mm) 3 COM2(RS-485) sending communication (Tx) indicator 14 Extension module fastening clip 4 Input/output indicator 15 COM2 (RS-485) communication port (Master/Slave) 5 RUN/STOP switch 16 Power input port 6 VR0: M1178 enabled/D1178 corresponding value 17 3 P removable terminal (standard component) 7 VR1: M1179enabled/D1179 corresponding value 18 Power input connection cable (standard component) 8 Input/output terminal 19 New high-speed extension module connection port 9 COM1(RS-232) program I/O communication port 20 Nameplate 21 Direct fastening hole 3 < 0.3A 4 C0 5 TRANSISTOR OUTPUT RELAY OUTPUT 6 1. DVP-SV series have two output modules, relay and transistor. See “Specifications” for their specifications. 2. Be aware of the connection of shared terminals when wiring output terminals. 3. Output terminals, Y0, Y1, and Y2, of relay models use C0 common port; Y3, Y4, and Y5 use C1 common port; Y6, Y7, and Y10 use C2 common port; Y11, Y12, and Y13 use C3 common port, as shown in the next page. C0 Y0 Y1 Y2 C1 Y3 Y4 Y5 C2 Y6 Y7 Y10 C3 Y11 Y12 Y13 When output points are enabled, their corresponding indicators on the front panel will be on. 4. Output terminals, Y0 and Y1, of transistor models use C0 common port; Y2 and Y3 use C1 common port; Y4 and Y5 use C2 common port; Y6 and Y7 use C3 common port; Y10, Y11, Y12 and Y13 use C4 common port, as shown below. 7 8 9 10 11 5 2 LOAD C0 C1 Y3 Y4 C2 Y6 Y7 Y0 Y1 Y0 LED 9 3 POWER RY 3 1 6 C0 R 2 1. Use 22-16AWG (1.5mm) single or multiple core wire on I/O wiring terminals. The specification of the terminal is shown in the figure on the left. The PLC terminal screws shall be tightened to 1.95 kg-cm (1.7 in-lbs). 2. DO NOT place the I/O signal wires and power supply wire in the same wiring duct. 3. Use 60/75 ºC copper wires only. Dust, smoke, metallic debris, corrosive or flammable gas High temperature, humidity Direct shock and vibration Power input wiring The power input of DVP-SV series is DC. When operating SV series, please make sure that: 1. The power is connected to the two terminals, 24V DC and 0V, and the range of power is 20.4 ~ 28.8V DC. If the power voltage is less than 20.4V DC, PLC will stop running, all outputs will go “Off” and ERROR indicator will flash continuously. 2. The power shutdown of less than 10 ms will not affect the operation of PLC. However, power shutdown time that is too long or the drop of power voltage will stop the operation of PLC and all outputs will go “Off”. When the power supply turns normal again, PLC will automatically return to its operation. (Please be aware of the latched auxiliary relays and registers inside PLC when programming.) MC1 MC2 C 10 7 DVP28SV11T (具直流輸入電源極性反接保護) MAX 2.2A @24V DC 2.5A/30V DC ,可恢復式 (Polyswitch) 6W 5 MΩ ( 500V DC) ESD(IEC 61131-2, IEC 61000-4-2): 8KV Air Discharge EFT(IEC 61131-2, IEC 61000-4-4): Power Line: 2KV, Digital I/O: 1KV, Analog & Communication I/O: 1KV Damped-Oscillatory Wave: Power Line: 1KV, Digital I/O: 1KV RS(IEC 61131-2, IEC 61000-4-3): 26MHz ~ 1GHz, 10V/m PLC 以上 所有輸出/入點對地之間 接地 接地配線之線徑不得小於電源端配線線徑(多台 同時使用時,請務必單點接地) 0ºC ~ 55ºC(溫度)50 ~ 95%(濕度)污染等級 2 操作/儲存環境 操作: 儲存:-40ºC ~ 70ºC(溫度)5 ~ 95%(濕度) 耐振動/衝擊 國際標準規範 IEC61131-2, IEC 68-2-6 (TEST Fc)/ IEC61131-2 & IEC 68-2-27 (TEST Ea) 重量(約, g) 260g 240g 輸入點電氣規格 輸出點電氣規格 輸入形式 直 流(SINK 或 SOURCE) 輸出形式 繼電器-R 電晶體-T 輸入電流 電流規格 24VDC 5mA 1.5A/1 Emergency stop: Uses external switch X0~X7,X12~X13,X16~X17 OffOn 16.5VDC Fuse: Uses 5 ~ 10A fuse at the common port of output contacts to protect the output circuit. Varistor: To reduce the interference on AC load (R=100~120Ω, C=0.1~0.2uF) 動作位準 Empty terminal: not in use DC power supply Neon indicator AC power supply Incandescent light (resistive load) Manually exclusive output: Uses external circuit and forms an interlock, together with the PLC internal program, to ensure safety protection in case of any unexpected errors. DVP-**-**-**-T 5 C0 Y0 LOAD 觸 發 回 路 Y0 Y1 C4 Y10 Y11 Y12 Y13 0. 00.5 ..55A以下 A A以下 以下 C0 MC1 4 1 5 MC2 4 2 TRANSISTOR OUTPUT 以上 以上 X0~X17 OnOff 8VDC 以下 X10~X11,X14~X15 OffOn 18.5VDC 10 ms(由 D1020 及 D1021 反應時間 約 可作 10~60 ms 的調整) 電壓規格 最大負載 反應時間 機械壽命 電源 3 點數 24V S/S 0V 2A DC/DC 5V X0 X1 X2 DVP28SV11R DC power supply Emergency stop 24VDC Circuit protection fuse Flywheel diode (SB360 3A 60V) + inductive load Manually exclusive output: Uses external circuit and forms an interlock, together with the PLC internal program, to ensure safety protection in case of any unexpected errors. DVP28SV11T 16 一般 點@40ºC 高速 點 點 > 1KHz, 0.3A/1 @40ºC ≥ 1KHz, 30mA/1 @40ºC 以下 30VDC (電感性) Y5,Y7,Y10 ~ Y13 Y0,Y1,Y2,Y3,Y4,Y6 (電阻性) 最高為 10KHz 最高為 200KHz OffOn 20us OffOn 0.2us 約 10 ms OnOff 30us OnOff 0.2us 2×10 次 (無負載) 1.5×10 次 (5A 30VDC) 接點壽命 5×10 次 (3A 120VAC) 3×10 次 (5A 250VAC) 75VA 90W 7 5 5 4 機種型號與 I/O 配置 標準功能型主機 機種 0.3A/1 250VAC, 30VDC 輸入/ 輸入/輸出規格 輸入單元 輸出單元 形式 點數 形式 繼電器 3 20.4V~28.8V 點(5A/COM) Flywheel diode (SB360 3A 60V): To extend the life span of contact Transistor (T) contact circuit wiring LED DVP28SV11R 24V DC (-15% ~ 20%) 4 8 RELAY OUTPUT 18 電氣規格 機種 項目 電源電壓 突入電流 電源保險絲容量 消耗電力 絕緣阻抗 C4 Y10 Y11 Y12 Y13 DVP-**-**-**-R Figure 3 17 尺寸單位:mm 12 擴充機連接口 13 DIN 軌糟(35mm) 14 擴充機固定扣 15 COM2 (RS-485) 通訊口 (Master/Slave) 16 電源輸入口 17 3 P 脫落式端子(標準附件) 18 電源輸入連接線(標準附件) 19 新型高速擴充機連接口 20 銘牌 21 直接固定孔 電源、運行、電池低電壓及錯誤指示燈 通訊接收 (Rx) 指示燈 COM2 (RS-485) 通訊傳送 (Tx) 指示燈 輸出/入點指示燈 RUN/STOP 開關 VR0 :M1178 啟動/D1178 對應值 VR1 :M1179 啟動/D1179 對應值 輸出/入端子 COM1 (RS-232) 程式輸出/入通訊口 DIN 軌固定扣 擴充機定位孔 COM1 (RS-232) 雜訊免疫力 C0 Y0 Y1 C1 Y2 Y3 C2 Y4 Y5 C3 Y6 Y7 D > 50 mm Figure 2 (Unit: mm) 4.2 Wiring Notes 11 Y0 T R G LED C0 Relay (R) contact circuit wiring DO NOT install PLC in an environment with: 7 2 LOAD LOAD 5. Isolation circuit: The optical coupler is used to isolate signals between the circuit inside PLC and input modules. D 16 14 Source Type 9 6 11 Extension module positioning hole C3 Y 11 Y 12 Y 13 C0 Y0 Y1 C1 Y2 Y3 C2 Y4 Y5 C3 Y6 Y7 D < 1.5m m 5 10 DIN rail clip C1 Y3 Y4 Y5 C2 Y6 Y7 Y 10 D 3 8 4 1 S/S X0 X1 X2 X3 X4 X5 X6 X7 S/S X 10 X 11 X 12 X 13 How to screw: Please use M4 screw (see figure 2) according to the dimension of the product. Please install PLC in an enclosure with sufficient space around it to allow heat dissipation (see figure 3). Figure 1 13 X2 X0 DVP-**-**-11-R How to install DIN rail: DVP-PLC can be secured to a cabinet by using the DIN rail of 35mm in height and 7.5mm in depth. When mounting PLC to DIN rail, be sure to use the end bracket to stop any side-to-side movement of PLC and reduce the chance of wires being loosen. A small retaining clip is at the bottom of PLC. To secure PLC to DIN rail, place the clip onto the rail and gently push it up. To remove it, pull the retaining clip down and gently remove PLC from DIN rail, as shown in figure 1. 22 - 1 6AW G 3 15 X1 Output point wiring Transistor Point Wiring: 1 11 12 S/S X0 4.1 PLC Mounting Arrangements and Wiring Notes Thank you for choosing Delta DVP28SV. 28SV is a 28-point (16 input + 12 output) PLC MPU, offering various instructions and is with 16K Steps program memory, able to connect with all SS/SA/SX/SC/SV series extension models, including digital input/output (max. 512 input/output extension points), analog modules (A/D, D/A tranformation and termperature units) and all kinds of new high-speed extenstion modules. Its 4-group high-speed (200KHz) pulse outputs and the two new 2-axis interpolation instructions satisfy all kinds of applications. DVP28SV is small in size and easy to install. 19 60 +5V S/S SOURCE mode (common port for current output S/S) C0 Y0 Y1 Y2 9 21 10 SOURCE 24VDC 70 53.2 70 Wiring loop Installation & Wiring Introduction Product Profile and Outline 5 24G LED S/ S X0 X1 X2 X3 X4 X5 X6 X7 S/ S X10 X 11 X12 X13 Relay 16 Input point loop equivalent circuit +24V 24G Relay 8 4 7 I/Oconfiguration Point X2 6 DC Signal IN Sourcing Output DVP28SV11R X1 S/S Input/output specification 2 Sink Type - Standard Functional MPU Power S/S X0 SINK mode (common port for current input S/S) +24V - 1 20 3 X0 Model Name & I/O Configuration Model +24V 24G X0 1.5×105 times (5A 30VDC) 5×105 times (3A 120VAC) 3×104 times (5A 250VAC) 19 S/S Electrical life 3 Type 3 DVP28SV11R 90 Model Item 注意事項 Safety wiring Specifications 直流 Sink 或 Source 12 電晶體 I/O 繼電器 S/S X0 X1 X2 X3 X4 X5 X6 X7 S/S X10 X11 X12 X13 X15 X16 X17 C0 Y0 Y1 Y2 C1 Y3 Y4 Y5 C2 Y6 Y7 Y10 C3 Y11 Y12 Y13 配置 電晶體 S/S X0 X1 X2 X3 X4 X5 X6 X7 S/S X10 X11 X12 X13 X15 X16 X17 C0 Y0 Y1 C1 Y2 Y3 C2 Y4 Y5 C3 Y6 Y7 C4 Y10 Y11 Y12 Y13 4.1 安裝及配線 盤內安裝及配線 鋁軌之安裝方法: 鋁軌之安裝方法: 適合 35mm 之 DIN 鋁軌,主機欲掛於鋁軌時,先將 PLC 下方之固定塑膠片壓入,再將 PLC 由上方掛上再往下壓 即可。欲取下 PLC 時,PLC 底部下之固定塑膠片,以起子插入凹槽,向上撐開即可,該固定機構塑膠片為保持型, 當所有的固定片撐開後,再將 PLC 往上外方取出,如下圖一所示。 直接鎖螺絲方式: 直接鎖螺絲方式: 請依產品外型尺寸並使用 M4 鏍絲(請參考圖二)。PLC 在安裝時,請裝配於封閉式之控制箱內,其周圍應保持 一定之空間(如圖三所示),以確保 PLC 散熱功能正常。 70 53.2 D 90 109.4 101 4. C0 Y0 Y1 C1 Y2 Y3 C2 Y4 Y5 C3 Y6 Y7 D PLC 隔離回路:PLC 內部回路與輸入模組之間使用光耦合器作信號隔離。 DVP-**-**-**-R D 5 LOAD D > 50 mm 圖一 配線: 配線: 圖二 圖三 Y6 Y7 9 6 3 R MC1 M C2 C 10 輸出/入配線端請使用 22-16AWG (1.5mm) 單蕊祼線或多蕊線,端子規格如左所示。 端子鏍絲扭力為 1.95 kg-cm (1.7 Ib-in)。 2. 在配線時請勿請輸入點信號線與輸出點或電源等動力線置於同一線糟內。 3. 只能使用 60/75 ºC 銅導線。 請勿將 PLC 裝置於以下環境中 PLC 注意事項 電源端輸入配線 4.2 1. C1 Y3 Y4 C2 Y1 2 落塵大、油煙、金屬性粉塵、腐蝕性或可燃性氣體 高溫、結露 直接震動、衝擊 2. Y0 1 4 7 RELAY OUTPUT < 1. 5mm SV C0 3 POWER RY C0 1. 2 Y0 LED 8 22 -1 6AWG 機種為直流電源輸入,在使用上應注意下列事項: 電源請接於 24VDC 及 0V 兩端,電源範圍為 20.4 ~ 28.8V DC,當電源電壓低於 20.4V DC 時,PLC 會停止運 轉,輸出全部 Off,ERROR LED 快速閃爍。 當停電時間低於 10ms 時,PLC 不受影響繼續運轉,當停電時間過長或電源電壓下降將使 PLC 停止運轉,輸 出全部 Off,當電源恢復正常時,PLC 亦自動回復運轉。(PLC 內部具有停電保持的輔助繼電器及暫存器,使 用者在作程式設計規劃時應特別注意使用。) 24V DC (-15% ~ 20%) 突波吸收二極體 (SB360 3A 60V):可增加接點壽命 緊急停止:使用外部開關 保險絲:使用 5 ~ 10A 的保險絲容量於輸出接點的共用點,保護輸出點回路。 突波吸收器:可減少交流負載上的雜訊 (R = 100 ~ 120Ω, C = 0.1 ~ 0.24uF) 空端子:不使用 直流電源供給 指示燈:氖燈 交流電源供給 白熾燈(電阻性負載) 互斥輸出:利用外部電路形成互鎖,配合 PLC 內部程式,確保任何異常突發狀況發生時,均有安全 的保護措施。 電晶體 (T) 接點回路配線 DVP-**-**-**-T 5 C0 Y0 LOAD 觸 發 回 路 LED Y0 Y1 MC1 C0 4 1 6W 4 1 以上(所有输出/入点对地之间 ) 输入信号 电压 电压规格 X10 ~ X11,X14 ~ X15 OffOn 18.5V DC 最大负载 X0 ~ X17 OnOff 8VDC 反应时间 机械寿命 以上 以上 以下 10 ms(由 D1020 及 D1021 可 反应时间 约 作 10~60 ms 的调整) 接点寿命 3 电源 X0 X1 X2 2A 5V DC/DC 5 MC 1 4 8 2 Guard Limit MC 3 MC 1 L 7 N 6 注意事項 安全配線回路 由於 DVP28SV 的電源為 DC Only 的機種,因此可搭配台達之電源供應模組 (DVPPS01/DVPPS02) 提供電源給 DVP28SV。為保護 DVPPS01/DVPPS02,可在電源端輸入回路端建議配置如下的保護回路: 輸入點之配線 交流電源負載 電源回路保護用保險絲 (3A) 電源指示燈 緊急停止 為預防突發狀況發生,設置一緊急停止按鈕,可在狀 況發生時,切斷系統電源。 系統回路隔離裝置 使用電磁接觸器、繼電器等開關作為系統電源回路隔 離裝置,可防止電源斷續供應時,造成系統的不穩定。 DVPPS01/DVPPS02 本體 接地 電源供應:交流 (AC):100 ~ 240V AC, 50/60Hz 輸入點之入力信號為直流電源 DC 輸入型式,共有兩種接法:SINK 及 SOURCE,其定義如下: 直流形式(DC Signal IN) 輸入點回路等效電路 配線回路 S/S 24VDC 详细说明请见 DVP-PLC 应用技术手册【程序篇】,选购外围装置详细说明请见该产品随机手册或 DVP-PLC 应用技术手册【特殊模块篇】。 本机为开放型 (OPEN TYPE) 机壳,因此使用者使用本机时,必须将之安装于具防尘、防潮及免于电击/冲 击意外之外壳配线箱内。另必须具备保护措施(如:特殊之工具或钥匙才可打开)防止非维护人员操作或意 外冲击本体,造成危险及损坏。 交流输入电源不可连接于输入/出信号端,否则可能造成严重损坏,请在上电之前再次确认电源配线。请勿 在上电时触摸任何端子。本体上之接地端子 务必正确的接地,可提高产品抗噪声能力。 產品簡介 谢谢您采用台达 DVP 系列可编程控制器。SV 为 28 点(16 输入点 + 12 输出点)PLC 主机,提供丰富的指令集, 并具有 16K Steps 的程序内存,可连接 SS/SA/SX/SC/SV 全系列扩展机,包含数字输入/输出(最大输入/输出扩 展点数可达 512 点)、模拟模块(A/D、D/A 转换及温度单元)及新型高速扩展机等各类机型。四组高速(200KHz) 脉冲输出、新增两轴插补指令,可满足各种应用场合,并且体积小,安装容易。 产品外观及各部介绍 SINK +24V Sinking 简体中文 本使用说明书仅提供电气规格、功能规格、安装配线部份说明,其它详细之程序设计及指令与 EH 系列兼容, +5V 24G 70 S/S 模式 (電流流入共用端 S/S) +24V 24G X0 S/S X0 X1 X2 19 1 20 2 Sink Type 輸入點回路等效電路 4 24VDC S/S 模式 (電流流出共用端 S/S) +24V 24G SOURCE S/S X0 X1 X2 12 X0 15 Source Type 13 輸出點之配線 14 DVP-**-**-11-T LOAD LOAD Y0 POWER RY C0 LED T R G Y0 1 < 0.3A 2 C0 3 RELAY OUTPUT TRANSISTOR OUTPUT 系列 PLC 輸出模組共有二種:繼電器及電晶體,其相關電氣規格請參考功能規格部份 2. 輸出端在實際配線時,應特別注意共用端的連接。 3. 繼電器機種輸出端 Y0、Y1、Y2 用 C0 共同端,Y3、Y4、Y5 用 C1 共同端,Y6、Y7、Y10 共用 C2 共同端, Y11、Y12、Y13 共用 C3 共同端,如下圖所示: 1. DVP-S 4 5 6 7 8 9 10 11 继电器 S/S X0 X1 X2 X3 X4 X5 X6 X7 S/S X10 X11 X12 X13 继电器 直流 Sink 或 12 Source 晶体管 X15 X16 X17 C0 Y0 Y1 Y2 17 18 C3 Y 11 Y 12 Y 13 X 15 X 16 X 17 C4 Y 10 Y 11 Y 12 Y 13 电源、运行、电池低电压及错误指示灯 COM1 (RS-232) 通讯接收 (Rx) 指示灯 COM2 (RS-485) 通讯传送 (Tx) 指示灯 输出/入点指示灯 RUN/STOP 开关 VR0 :M1178 启动/D1178 对应值 VR1 :M1179 启动/D1179 对应值 输出/入端子 COM1 (RS-232) 程序输出/入通讯口 DIN 轨固定扣 扩展机定位孔 尺寸单位:mm 12 扩展机连接口 13 DIN 轨糟 (35mm) 14 扩展机固定扣 15 COM2 (RS-485) 通讯口 (Master/Slave) 16 电源输入口 17 3 P 脱落式端子 (标准附件) 18 电源输入连接线 (标准附件) 19 新型高速扩展机连接口 20 铭牌 21 直接固定孔 X1 X2 配线回路 +5V 24G S/S Sourcing +24V 24G S/S X0 X0 Source Type 输出点之配线 LED DVP-**-**-11-T LOAD POWER RY Y0 T R G LED C0 < 0.3A C0 TRANSISTOR OUTPUT RELAY OUTPUT 系列 PLC 输出模块共有二种:继电器及晶体管,其相关电气规格请参考功能规格部份。 输出端在实际配线时,应特别注意共享端的连接。 继电器机种输出端 Y0、Y1、Y2 用 C0 共同端,Y3、Y4、Y5 用 C1 共同端,Y6、Y7、Y10 共享 C2 共同端, Y11、Y12、Y13 共享 C3 共同端,如下图所示: 1. DVP-S 2. 3. 安裝及配線 C0 Y0 Y1 C1 Y2 Y3 C2 Y4 Y5 C3 Y6 Y7 5. PL C D 动作指示:当输出点动作时,正面的该点指示灯亮。 晶体管机种输出端 Y0、Y1 用 C0 共同端,Y2、Y3 用 C1 共同端,Y4、Y5 共享 C2 共同端,Y6、Y7 共享 C3 共同端,Y10 、Y11、Y12、Y13 共享 C4 共同端如下图所示: C0 Y0 Y1 Y2 C1 Y3 Y4 Y5 C2 Y6 Y7 Y10 C3 Y11 Y12 Y13 4. 图一 图二 C4 Y10 Y11 Y12 Y13 隔离回路:PLC 内部回路与输入模块之间使用光耦合器作信号隔离。 继电器 (R) 接点回路配线 DVP-**-**-**-R 5 D 2 LOAD C0 C1 Y3 Y4 C2 Y6 Y7 Y0 Y1 Y0 图三 LED 9 3 POWER RY 3 1 6 C0 R 2 MC1 MC2 C 10 输出/入配线端请使用 22-16AWG (1.5mm) 单蕊祼线或多蕊线,端子规格如左所示。 PLC 端子镙丝扭力为 1.95 kg-cm (1.7 Ib-in)。 2. 在配线时请勿请输入点信号线与输出点或电源等动力线置于同一线糟内。 3. 只能使用 60/75 ºC 铜导线。 请勿将 PLC 装置于以下环境中 落尘大、油烟、金属性粉尘、腐蚀性或可燃性气体 高温、结露 直接震动、冲击 注意事项 电源端输入配线 机种为直流电源输入,在使用上应注意下列事项: 电源请接于 24VDC 及 0V 两端,电源范围为 20.4VDC ~ 28.8VDC,当电源电压低于 20.4VDC 时,PLC 会停止 运行,输出全部 Off,ERROR LED 快速闪烁。 当停电时间低于 10ms 时,PLC 不受影响继续运行,当停电时间过长或电源电压下降将使 PLC 停止运行,输 出全部 Off,当电源恢复正常时,PLC 也自动回复运行。(PLC 内部具有停电保持的辅助继电器及寄存器,使 用者在作程序设计规划时应特别注意使用。) 7 突波吸收二极管 (SB360 3A 60V):可增加接点寿命 紧急停止:使用外部开关 保险丝:使用 5 ~ 10A 的保险丝容量于输出接点的共享点,保护输出点回路。 突波吸收器:可减少交流负载上的噪声 (R = 100 ~ 120Ω, C = 0.1 ~ 0.24uF) 空端子:不使用 直流电源供给 指示灯:氖灯 交流电源供给 白炽灯(电阻性负载) 互斥输出:利用外部电路形成互锁,配合 PLC 内部程序,确保任何异常突发状况发生时,均有安全的 保护措施。 晶体管 (T) 接点回路配线 DVP-**-**-**-T LED 5 觸 發 回 路 C0 Y0 Y1 LOAD Y0 M C1 4 1 S/S 0V 2A X0 X1 X2 2 DC/DC M C2 4 3 3 24V 5 C4 Y10 Y11 Y12 Y13 00.5 ...55A以下 A A以下 以下 C0 TRANSISTOR OUTPUT 20.4V~28.8V 4 8 RELAY OUTPUT 22 -1 6AWG 2. X2 S/S SOURCE 模式 (电流流出共享端 S/S) 晶体管 C0 Y0 Y1 C1 Y2 Y3 C2 Y4 Y5 C3 Y6 Y7 X1 SOURCE 24VDC 盘内安装及配线 配线: 配线: SV 输入点回路等效电路 LOAD S /S X0 X1 X2 X3 X4 X5 X6 X7 S /S X 10 X 11 X 12 X 13 C1 Y3 Y4 Y5 C2 Y6 Y7 Y 10 S/S X0 Sink Type +24V D > 50 mm 1. DVP-**-**-11-R LED 16 +24V 24G X0 X0 4.2 11 S/S Sourcing S/S 模式 (电流流入共享端 S/S) 直流形式(DC Signal IN) Y0 D 21 60 24G X0 SINK < 1. 5mm +5V +5V DVP-**-**-11-R 配置 I/O D 3 10 SOURCE +24V 24VDC 24G 70 53.2 7 配线回路 SINK +24V Sinking 7 铝轨之安装方法: 铝轨之安装方法: 适合 35mm 的 DIN 铝轨,主机挂于铝轨时,先将 PLC 下方的固定塑料片压入,再将 PLC 由上方挂上再往下压即 可。欲取下 PLC 时,PLC 底部下的固定塑料片,以起子插入凹槽,向上撑开即可,该固定机构塑料片为保持型, 当所有的固定片撑开后,再将 PLC 往上外方取出,如下图一所示。 直接锁螺丝方式: 直接锁螺丝方式: 请按产品外型尺寸并使用 M4 镙丝(请参考图二)。PLC 在安装时,请装配于封闭式的控制箱内,其周围应保持 一定的空间(如图三所示),以确保 PLC 散热功能正常。 9 6 输入点回路等效电路 S/S DIN 5 配線回路 X0 4.1 8 3 直流形式(DC Signal IN) 直流形式(DC Signal IN) 1. X0 SINK 交流电源负载 电源回路保护用保险丝 (3A) 电源指示灯 紧急停止 为预防突发状况发生,设置一紧急停止按钮,可在状况发 生时,切断系统电源。 系统回路隔离装置 使用电磁接触器、继电器等开关作为系统电源回路隔离装 置,可防止电源断续供应时,造成系统的不稳定。 DVPPS01/DVPPS02 本体 接地 电源供应: 交流 (AC):100 ~ 240V AC, 50/60Hz 输入点的入力信号为直流电源 DC 输入型式,共有两种接法:SINK 及 SOURCE,其定义如下: 5 DVP28SV11T 90 24VDC 7 N 输入点之配线 4 输入/ 输入/输出规格 输入单元 输出单元 点数 形式 点数 形式 16 MC 6 5 90 S/S 0V L 30VDC 以下 Y5,Y7,Y10 ~ Y13 Y0,Y1,Y2,Y3,Y4,Y6 75VA(电感性) 最高为 10KHz 最高为 200KHz 90W(电阻性) OffOn 20us OffOn 0.2us 约 10 ms OnOff 30us OnOff 0.2us 2×10 次(无负载) 1.5×10 次 (5A 30VDC) 5×10 次 (3A 120VAC) 3×10 次 (5A 250VAC) DVP28SV11R 3 24V 3 1 250VAC, 30VDC 109.4 101 20.4V~28.8V 直流電源供應 緊急停止 電路回路保護用保險絲 突波吸收二極體 (SB360 3A 60V) +電感性負載 互斥輸出:利用外部電路形成互鎖,配合 PLC 內部程式,確保任何異常突發狀況發生時,均有安全 的保護措施。 2 Guard Limit MC @40ºC X0 ~ X7,X12 ~ X13, X16 ~ X17 OffOn 16.5V DC MC 4 3 5 8 5 MΩ 500V DC ESD (IEC 61131-2, IEC 61000-4-2): 8KV Air Discharge EFT (IEC 61131-2, IEC 61000-4-4): Power Line: 2KV, Digital I/O: 1KV, Analog & Communication I/O: 1KV Damped-Oscillatory Wave: Power Line: 1KV, Digital I/O: 1KV RS(IEC 61131-2, IEC 61000-4-3): 26MHz ~ 1GHz, 10V/m PLC 機種型號與 I/O 配置 M C2 2 TRANSISTOR OUTPUT (具直流输入电源极性反接保护) ,可恢复式 (Polyswitch) 2.5A/30V DC 接地 接地配线的线径不得小于电源端配线线径(多台 同时使用时,请务必单点接地) 操作:0ºC ~ 55º C(温度)50 ~ 95%(湿度)污染等级 2 操作/储存环境 储存:-40ºC ~ 70ºC(温度)5 ~ 95%(湿度) 国际标准规范 IEC61131-2, IEC 68-2-6 (TEST Fc)/ IEC61131-2 & IEC 68-2-27 (TEST Ea) 耐振动/冲击 260g 260g 重量(约, g) 输入点电气规格 输出点电气规格 直流( SINK 或 SOURCE ) 输出形式 继电器 -R 晶体管-T 输入形式 高速 > 1KHz, 0.3A/1 点 一般 输入信号 24V DC 5mA 电流规格 1.5A/1 点(5A/COM) 0.3A/1 点@40ºC @40ºC 电流 ≥ 1KHz, 30mA/1 点 標準功能型主機 机种 5 C4 Y10 Y11 Y12 Y13 0. 00.5 ..5A 55A A以下 以下 由于 DVP28SV 的电源为 DC Only 的机种,因此可搭配台达的电源供应模块 (DVPPS01/DVPPS02) 提供电源给 DVP28SV。为保护 DVPPS01/DVPPS02,可在电源端输入回路端建议配置如下的保护回路: DVP28SV11T MAX 2.2A @24V DC C4 Y10 Y11 Y12 Y13 繼電器 (R) 接點回路配線 安全配线回路 DVP28SV11R 噪声免疫力 5. D 動作指示:當輸出點動作時,正面的該點指示燈亮。 電晶體機種輸出端 Y0、Y1 用 C0 共同端,Y2、Y3 用 C1 共同端,Y4、Y5 共用 C2 共同端,Y6、Y7 共用 C3 共同端,Y10、Y11、Y12、Y13 共用 C4 共同端如下圖所示: C0 Y0 Y1 Y2 C1 Y3 Y4 Y5 C2 Y6 Y7 Y10 C3 Y11 Y12 Y13 DIN 電氣規格 机种 项目 电源电压 突入电流 电源保险丝容量 消耗电力 绝缘阻抗 5V 直流电源供应 紧急停止 电路回路保护用保险丝 突波吸收二极管 (SB360 3A 60V) + 电感性负载 互斥输出:利用外部电路形成互锁,配合 PLC 内部程序,确保任何异常突发状况发生时,均有安全的 保护措施。
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Page Count : 2 Producer : GPL Ghostscript 8.15 Create Date : 2007:09:06 10:23:03 Modify Date : 2007:09:06 10:23:03 Title : 5011669000-SV00.doc Creator : PScript5.dll Version 5.2 Author : LINDA.TY.CHENEXIF Metadata provided by EXIF.tools