Note: SUB1 and SUB2 do not support DTE20L and DTE20C. Please install the optional output modules you purchase into Operation altitude < 2,000m Ambient humidity 35% to 85% RH (non-condensing) Pollution degree 2 the correct slot. Communication Address of Output & How to Set up Parameters: See Table 2 for the communication addresses of output and Table 3 for the definition of the value in the address. Product Profile & Outline! INA Series Temperature Controller Instruction Sheet DTE10T/P Thank you very much for choosing Delta DTE series temperature controller. Please read this instruction sheet carefully before using your DTE to ensure proper operation. Keep this instruction sheet handy for quick reference. CH2 CH3 CH4 CH5 CH6 CH7 CH8 OUT1, OUT2 H10A8 H10A9 H10AA H10AB H10AC H10AD H10AE H10AF SUB1, SUB2 H10B0 H10B1 H10B2 H10B3 H10B4 H10B5 H10B6 H10B7 Table 2 I/O terminals 2 Status LED 3 Display and setup unit DANGER! CAUTION! ELECTRIC SHOCK! 4 DIN rail clip DTE is an OPEN-TYPE device and therefore should be installed in an enclosure free of airborne dust, humidity, electric shock and vibration. The enclosure should prevent non-maintenance staff from operating the device (e.g. key or specific tools are required for opening the enclosure) in case danger and damage on the device may occur. 5 Power input port 6 RS-485 communication port Table 3 7 Extension module fixing clip 8 Extension port *When there are only 4 channels of inputs, SUB1 cannot be used for alarm output but heating/cooling control only. **When there are only 4 channels of inputs, OUT2 and SUB2 cannot be set up by the user but set up automatically as "alarm 1. Prevent dust or metallic debris from falling into the device and cause malfunctions. DO NOT modify or uninstall the circuit board of DTE without being permitted. DO NOT use empty terminals. (a) dust or corrosive gas; (b) high humidity and high radiation; (c) shock and vibration. 3. The power has to be switched off when wiring or changing the temperature sensor. Input The standard DTE main unit is attached with 4 channels of inputs. You can purchase additional DTE20T or DTE20P to expand the number of input channels. DTE supports maximum 8 channels of inputs which belong to group INA and group INB. Each group possesses 4 input channels. Input Sensor Type Register Value 3 1: main unit 2: accessory 0T: 4-channel TC 0P: 4-channel PT 0T: 4-channel TC 0P: 4-channel PT 0V: 4 channels of voltage pulse output 0C: 4 channels of linear current output 0R: 4 channels of relay output 0L: 4 channels of linear voltage output CT: 4 channels of current transformer sensors DS: Display and setup module Temperature measurement resistance (Cu50) 13 -50 ~ 150°C Platinum resistance (Pt100) 12 -200 ~ 600°C Platinum resistance (JPt100) Thermocouple TXK type Functions & Electrical Specifications! Power input DC 24V, isolated switching power supply Voltage range 90% ~ 110% rated voltage Power consumption Max. 10W + 3W × number of DTC2000 controllers connected in parallel (Max. 7) Input sensor Thermocouple: K, J, T, E, N, R, S, B, L, U, TXK Platinum resistance: Pt100, JPt100, Cu50 Sampling cycle Thermocouple or platinum resistance: 1.0 second/all input Control method PID, PID programmable, manual, ON/OFF Relay output: SPST, Max. AC 250V load, 3A resistive load Output accessories (optional) Voltage pulse output: DC 24V, Max. 40mA current output Current output: DC 4 ~ 20mA output (resistive load < 500Ω); for OUT1 and OUT2 only 11 For DTE10T / DTE20T 10 -20 ~ 400°C -200 ~ 800°C Thermocouple U type 9 -200 ~ 500°C Thermocouple L type 8 -200 ~ 850°C Thermocouple B type 7 100 ~ 1,800°C Thermocouple S type 6 0 ~ 1,700°C Thermocouple R type 5 0 ~ 1,700°C Thermocouple N type 4 -200 ~ 1,300°C Thermocouple E type 3 0 ~ 600°C Thermocouple T type 2 -200 ~ 400°C Thermocouple J type 1 -100 ~ 1,200°C Thermocouple K type 0 -200 ~ 1,300°C Communication address: Input sensor types at H10A0 ~ H10A7; input upper limits at H1010 ~ H1017; input lower limits at H1018 ~ H101F. Output Without group INB (4 channels of input): Every channel corresponds to 2 groups of output and 2 groups of alarms. OUT1 and SUB1 are for control output, and OUT1 can be used for proportional output. OUT2 and SUB2 are fixed for alarm output. Output functions Control output, alarm output or proportional output (proportional output is only applicable in the model with linear voltage and current output for OUT1, OUT2) See Table 1 for the relations between input and output. Alarm modes 12 alarm modes available Communication RS-485 digital communication; supports baud rate 2,400bps ~ 115,200bps Communication protocol 4 channels of input 8 channels of input INA (CH1 ~ CH4) INA (CH1 ~ CH4) INB (CH5 ~ CH8) Supports Modbus ASCII/RTU OUT1 Main control output or proportional output Main control output or proportional output No corresponding output Extension port The extension port transmits 24V power supply and communication signals to extension module DTC2000. OUT2 Alarm 1 output No corresponding output Main control output or proportional output Vibration resistance 10 ~ 55Hz SUB1 Control output Control output or alarm output No corresponding output Shock resistance Max. 300m/s SUB2 Alarm 2 output No corresponding output Control output or alarm output Ambient temperature 0°C ~ +50°C Storage temperature -20°C ~ +65°C 2 10mins 3 axes 6 directions, 3 times each Heating control Cooling control Alarm output* Disable output SV Alarm Mode 0 No alarm Alarm output is enabled when the temperature reaches upper and lower limits: The alarm will be enabled when PV exceeds SV + AL-H or falls below SV – AL-L. Alarm output will be enabled when the temperature reaches the upper limit: The alarm will be enabled when the PV exceeds SV + AL-H. 3 Alarm output will be enabled when the temperature reaches the lower limit: The alarm will be enabled when the PV falls below SV – AL-L. 4 Alarm output will be enabled when the PV is between SV + AL-H and SV – AL-L. Alarm output will be enabled when the temperature reaches the absolute value of the upper and lower limits: The alarm will be enabled when the PV exceeds AL-H or falls below AL-L. Alarm output will be enabled when the temperature reaches the absolute value of the upper limit: The alarm will be enabled when the PV exceeds AL-H. Alarm output will be enabled when the temperature reaches the absolute value of the lower limit: The alarm will be enabled when the PV falls below AL-L. 5 6 7 Upper/lower limit standby alarm: The alarm will be enabled when the PV reaches SV and further exceeds SV + AL-H or falls below SV – AL-L. 8 9 Upper limit standby alarm: The alarm will be enabled when the PV reaches SV and further exceeds SV + AL-H. 10 Lower limit standby alarm: The alarm will be enabled when the PV reaches SV and further falls below SV – AL-L. Upper limit hysteresis alarm: The alarm will be enabled when the PV exceeds SV + AL-H. The alarm will be disabled when the PV falls below SV + AL-L. 11 12 Lower limit hysteresis alarm: The alarm will be enabled when the PV falls below SV – AL-H. The alarm will be disabled when the PV exceeds SV – AL-L. Alarm Output Operation Off ON OFF AL-L SV AL-H SV AL-H ON OFF ON OFF AL-L SV AL-L SV ON OFF AL-H ON OFF AL-L AL-H ON OFF AL-H ON OFF AL-L ON OFF AL-L SV AL-H SV AL-H ON OFF ON OFF AL-L SV ON OFF AL-L AL-H ON OFF AL-H AL-L PWR: On B DTE is powered. RUN: On B Any of the channel is executing. COM: Flashing B Communication in progress ERR: Indicating errors (red) ERR LED is on indicates one of the following errors occur, and the output has to be disabled. 1. Memory EEPROM error. Output Group 3 axes SUB1, SUB2** LED Display DTE supports maximum 16 channels of outputs, belonging to output groups OUT1, OUT2, SUB1 and SUB2, each group with 4 channels. See the explanations below for how input channels correspond to output groups. With group INB (8 channels of input): Every channel is paired with 2 groups of outputs. OUT1 and OUT2 are used for control output or proportional output of CH1 ~ CH8. SUB1 and SUB2 are used for control output or alarm output. 2 Disable output Note: The default setting in DTE10T is “thermocouple K type”. The default setting in DTE10P is “Pt100". Analog voltage output: 0 ~ 10V (resistive load > 1,000Ω); for OUT1 and OUT2 only 10m/s Proportional output Range For DTE10P / DTE20P Device type Cooling control 2 DTE series supports the following input sensors: DTE: Delta E series temperature controller Heating control 1 8. DO NOT touch the terminal or repair the device when the power is on; otherwise an electric shock may occur. Series name OUT1, OUT2** DTE offers 12 alarm modes. The alarm modes are set up at address H10C0 ~ H10C7, upper limits at H1080 ~ H1087 and lower limits at H1088 ~ H108F. 7. Make sure the power cables and signal device are installed correctly before switching on the power; otherwise serious damage may occur. Ordering Information! Value = 3 Alarm Output: 6. Keep the wire as short as possible when wiring a sensor to the controller. Separate the power cable and load wire in order to prevent interference and induced noise. 11. Please place DTE with other heating objects (e.g. power supply) within proper distance while installing DTE. Value = 2 DTE offers PID control, ON/OFF control, manual control and programmable PID control. Control output methods are set at address H10B8 ~ H10BF (default = 0: PID), PID parameters at H1028 ~ H105F, ON/OFF parameters at H1058 ~ H106F, and manual control parameters at H1070 ~ H107F. Panel Layout! 5. Make sure to use compensation wire which matches the thermocouple or platinum resistance when extending or connecting the thermocouple or platinum resistance. 10. DO NOT touch the internal terminal when DTE is either switched on or off in case you may damage the circuit. Value = 1 Control Output: 4. When installing the circuit board of the accessory, please make sure the power of the main unit is switched off and insert the accessory into the correct slot on the main unit. 9. Please wait for 1 minute after the power is switched off to allow the capacitor to discharge and DO NOT touch the internal wiring within this period. Value = 0 output” by the controller. 2. Keep away from high-voltage and high-frequency environment during the installation in case of interference. Prevent using the device in premises which contain: 2 CH1 1 Warning 1 INB Table 1 2. Any of the input points is not connected. 3. Any of the input points exceeds the setup range. 4. Any of the input temperatures has not been stabilized. Synchronous Communication Protocol & Auto ID Setup This function allows the auto setup of communication protocol in extension module DTC2000 and DTC2001 following the communication protocol set in the DTE main unit. The station IDs of DTC decrease. See below for the steps. 1. Set the auto communication ID of DTE as “1” (communication address: H10F8). 2. Switch off DTE. Connect DTE with extension module DTC2000, DTC2001 and switch on DTE again. 3. Default communication protocol: 9,600bps, 7 bits, Even, 1 stop bit, communication address = 01. 4. This function will consume 3 ~ 5 seconds more when you switch on DTE. INA RS-485 Communication Content 1. DTE supports baud rates 2,400/4,800/9,600/19,200/38,400/57,600/115,200 bps and does not support communication format 7, N, 1/8, E, 2/8, O, 2. Communication protocol = Modbus ASCII or RTU. 2. Function codes: H03 = read maximum 8 words in the register; H06 = write 1 word into the register. 3. Address and contents: Every parameter has 2 communication addresses. One is numbered by the function of the parameter, and the other is by the order of channel (as shown in the table below). INA Content Present temperature value/input error code Explanation Unit; 0.1 See Table 5 CH1 CH2 INB CH3 CH4 CH5 CH6 CH7 CH8 H1000 H1001 H1002 H1003 H1004 H1005 H1006 H1007 (H1100) (H1200) (H1300) (H1400) (H1500) (H1600) (H1700) (H1800) H1008 H1009 H100A H100B H100C H100D H100E H100F (H1101) (H1201) (H1301) (H1401) (H1501) (H1601) (H1701) (H1801) Set temperature value Unit: 0.1 Max. temperature value Disabled when higher H1010 H1011 H1012 H1013 H1014 H1015 H1016 H1017 than default value (H1102) (H1202) (H1302) (H1402) (H1502) (H1602) (H1702) (H1802) Min. temperature value Disabled when lower H1018 H1019 H101A H101B H101C H101D H101E H101F than default value (H1103) (H1203) (H1303) (H1403) (H1503) (H1603) (H1703) (H1803) Error temperature value -999 ~ +999 Unit: 0.1°C H1020 H1021 H1022 H1023 H1024 H1025 H1026 H1027 (H1104) (H1204) (H1304) (H1404) (H1504) (H1604) (H1704) (H1804) Proportional band value (Pb) 0 ~ 9,999 Unit: 0.1 H1028 H1029 H102A H102B H102C H102D H102E H102F (H1105) (H1205) (H1305) (H1405) (H1505) (H1605) (H1705) (H1805) Ti value 0 ~ 9,999 H1030 H1031 H1032 H1033 H1034 H1035 H1036 H1037 (H1106) (H1206) (H1306) (H1406) (H1506) (H1606) (H1706) (H1806) Td value 0 ~ 9,999 H1038 H1039 H103A H103B H103C H103D H103E H103F (H1107) (H1207) (H1307) (H1407) (H1507) (H1607) (H1707) (H1807) 0.0 ~ 100.0% Unit: 0.1% H1040 H1041 H1042 H1043 H1044 H1045 H1046 H1010 (H1108) (H1208) (H1308) (H1408) (H1508) (H1608) (H1708) (H1808) Proportional control 0.0 ~ 100.0% offset error value, Unit: 0.1% when Ti = 0 H1048 H1049 H104A H104B H104C H104D H104E H104F (H1109) (H1209) (H1309) (H1409) (H1509) (H1609) (H1709) (H1809) Proportional band 0.01 ~ 99.99 coefficient of output Unit: 0.01 1 and output 2 H1050 H1051 H1052 H1053 H1054 H1055 H1056 H1057 (H110A) (H120A) (H130A) (H140A) (H150A) (H160A) (H170A) (H180A) Dead band of control output 1 & output 2. -99.9 ~ 999.9 H1058 H1059 H105A H105B H105C H105D H105E H105F (H110B) (H120B) (H130B) (H140B) (H150B) (H160B) (H170B) (H180B) Hysteresis for output 1 0 ~ 9,999 Unit: 0.1% H1060 H1061 H1062 H1063 H1064 H1065 H1066 H1067 (H110C) (H120C) (H130C) (H140C) (H150C) (H160C) (H170C) (H180C) Hysteresis for output 2 0 ~ 9,999 Unit: 0.1% H1068 H1069 H106A H106B H106C H106D H106E H106F (H110D) (H120D) (H130D) (H140D) (H150D) (H160D) (H170D) (H180D) Unit: 0.1 % H1070 H1071 H1072 H1073 H1074 H1075 H1076 H1077 (H110E) (H120E) (H130E) (H140E) (H150E) (H160E) (H170E) (H180E) Integration default Read/write output 1 value Explanation Run/Stop the control Status of PID auto-tuning CH1 CH2 CH3 CH4 CH5 CH6 CH7 H10D8 H10D9 H10DA H10DB H10DC H10DD H10DE H10DF (H111B) (H121B) (H131B) (H141B) (H151B) (H161B) (H171B) (H181B) 0: stop 1: executing H10E0 H10E1 H10E2 H10E3 H10E4 H10E5 H10E6 H10E7 (H111C) (H121C) (H131C) (H141C) (H151C) (H161C) (H171C) (H181C) 0: positive 1: negative (slope) Other statuses Other statuses H10E8 H10E9 H10EA H10EB H10EC H10ED H10EE H10EF (H111D) (H121D) (H131D) (H141D) (H151D) (H161D) (H171D) (H181D) H10F1 H10F0 H10F2 Open special Temperature function unit Return to default (H1234) (H1357) H10F8 See Table 4 Auto ID setup H10F9 H10FA Reserved Baud rate H10F3 H10F4 H10F5 H10F6 H10F7 Reserved Reserved Reserved Reserved Reserved H10FB H10FC H10FD ASCII = 0 RTU = 1 8 bits=0 7 bits=1 2 stop=0 1 stop=1 H10FE Parity H10FF Read start address of data/bit ‘0’ Length of response data (byte) ‘0’ ‘0’ ‘0’ ‘0’ ‘4’ ‘0’ Data content in H1000 Write Command Write Response Message ‘1’ Data address ‘0’ ‘0’ ‘0’ ‘1’ ‘1’ ‘1’ ‘0’ ‘F’ ‘0’ ‘0’ ‘4’ ‘3’ ‘0’ ‘0’ LRC1 check ‘E’ LRC0 check ‘A’ End word 1 CR End word 0 LF Data content in H1001 Data address ‘0’ Read length of data/bit (word/bit) ‘2’ ‘1’ Write data content ‘0’ ‘E’ Write data content ‘8’ ‘3’ ‘E’ ‘8’ ‘0’ LRC1 check ‘F’ LRC1 check ‘F’ ‘0’ LRC0 check ‘D’ LRC0 check ‘D’ LRC1 check ‘0’ End word 1 CR End word 1 CR LRC0 check ‘3’ End word 0 LF End word 0 LF End word 1 CR End word 0 LF LRC Check: Communication Parameter Setting: Sum up the contents from “machine address” to “data content”, e.g. H01 + H03 + H10 + H00 + H00 + H02 = H16. Obtain 2’scomplement H EA. Content 0 1 2 3 4 5 6 Baud rate 2,400bps 4,800bps 9,600bps 19,200bps 38,400bps 57,600bps 115,200bps Parity bit None (N) Even (E) Odd (O) RTU Mode: Read Command Table 4 Error Codes: The error codes can be read from address H1000 ~ H1007. When the input operation is in normal status, H1000 ~ H1007 are for input values. When input error occurs (except for stable status and input exceeding the range), DTE will read error codes in H8001 ~ H8002. H1000 Error description H8001 EEPROM cannot be written in. H8002 Input sensor is not connected. H8003 Group INB is not connected. Read Response Message Write Command Write Response Message Machine address H01 Machine address H01 Machine address H01 Machine address H01 Command H03 Command H03 Command H06 Command H06 Read start address of data H10 Read length of data (bit/word) H00 CRC low byte HC0 CRC high byte HCB H00 H02 Length of response data (byte) Data content 1 Data content 2 H04 H01 HF4 Write data address Write data content H10 H01 H03 H20 Write data address Write data content H10 H01 H03 H20 H03 CRC low byte HDD CRC low byte HDD H20 CRC high byte HE2 CRC high byte HE2 CRC low byte HBB CRC high byte H15 Table 5 CRC (Cyclical Redundancy Check) is obtained by the following steps: Analog output current tuning scale: 1μA/scale Analog output voltage tuning scale: 1mV/scale Returning to Default Value: Write H1234 into address H10F1 and H1357 into address H10F2. Restart DTE. Programmable Communication Parameter Setting: INA Content Explanation INB CH1 CH2 CH3 CH4 CH5 CH6 CH7 CH8 unsigned int reg_crc = 0xffff; i = 0; while (length--) { reg_crc ^= RTUData[i]; i ++; for (j = 0; j < 8; j++) { if (reg_crc & 0x01) else } } return(reg_crc); reg_crc = (reg_crc >> 1) ^ 0xA001; reg_crc = reg_crc >> 1; Read remaining time of the step Unit: sec H111E H121E H131E H141E H151E H161E H171E H181E Unit: min H111F H121F H131F H141F H151F H161F H171F H181F Software for Setting up Communication on PC: Download the free software on Delta’s website. How to Mount & DIN Rail Size Read/write output 2 value Unit: 0.1 % H1078 H1079 H107A H107B H107C H107D H107E H107F (H110F) (H120F) (H130F) (H140F) (H150F) (H160F) (H170F) (H180F) 0~7 H1120 H1220 H1320 H1420 H1520 H1620 H1720 H1820 Upper limit for alarm output Alarm enabled when temperature exceeds upper limit Read the NO. of the current pattern H1080 (H1110) Read the NO. of the current step 0~7 H1121 H1221 H1321 H1421 H1521 H1621 H1721 H1821 Lower limit for alarm output Alarm enabled when temperature falls below lower limit H1088 H1089 H108A H108B H108C H108D H108E H108F (H1111) (H1211) (H1311) (H1411) (H1511) (H1611) (H1711) (H1811) Tuning for upper limit of analog output Current (4 ~ 20mA) or voltage output tuning H1090 H1091 H1092 H1093 H1094 H1095 H1096 H1097 (H1112) (H1212) (H1312) (H1412) (H1512) (H1612) (H1712) (H1812) Tuning for lower limit of analog output Current (4 ~ 20mA) or voltage output tuning H1098 H1099 H109A H109B H109C H109D H109E H109F (H1113) (H1213) (H1313) (H1413) (H1513) (H1613) (H1713) (H1813) Input sensor type See “Input” section H10A0 H10A1 H10A2 H10A3 H10A4 H10A5 H10A6 H10A7 (H1114) (H1214) (H1314) (H1414) (H1514) (H1614) (H1714) (H1814) Output function for output 1 0: heating 1: cooling 2: proportional output H10A8 H10A9 H10AA H10AB H10AC H10AD H10AE H10AF (H1115) (H1215) (H1315) (H1415) (H1515) (H1615) (H1715) (H1815) Output function for output 2 0: heating (default) 1: cooling 2: alarm H10B0 H10B1 H10B2 H10B3 H10B4 H10B5 H10B6 H10B7 (H1116) (H1216) (H1316) (H1416) (H1516) (H1616) (H1716) (H1816) Control method 0: PID 1: ON-OFF 2: manual 3: PID programmable H10B8 H10B9 H10BA H10BB H10BC H10BD H10BE H10BF (H1117) (H1217) (H1317) (H1417) (H1517) (H1617) (H1717) (H1817) Alarm 1 output mode See “Alarm Output” section H10C0 H10C1 H10C2 H10C3 H10C4 H10C5 H10C6 H10C7 (H1118) (H1218) (H1318) (H1418) (H1518) (H1618) (H1718) (H1818) Alarm 2 output mode See “Alarm Output” section H10C4 H10C5 H10C6 H10C7 (H1518) (H1618) (H1718) (H1818) Start word ’:’ Start word ’:’ Start word ’:’ Start word ’:’ Heating/cooling cycle for output 1 1 ~ 99 seconds 0 = 0.5 second H10C8 H10C9 H10CA H10CB H10CC H10CD H10CE H10CF (H1119) (H1219) (H1319) (H1419) (H1519) (H1619) (H1719) (H1819) Machine address 1 ‘0’ Machine address 1 ‘0’ Machine address 1 ‘0’ Machine address 1 ‘0’ Machine address 0 ‘1’ Machine address 0 ‘1’ Machine address 0 ‘1’ Machine address 0 ‘1’ Heating/cooling cycle for output 2 1 ~ 99 seconds 0 = 0.5 second H10D0 H10D1 H10D2 H10D3 H10D4 H10D5 H10D6 H10D7 (H111A) (H121A) (H131A) (H141A) (H151A) (H161A) (H171A) (H181A) Command 1 ‘0’ Command 1 ‘0’ Command 1 ‘0’ Command 1 ‘0’ Command 0 ‘3’ Command 0 ‘3’ Command 0 ‘6’ Command 0 ‘6’ H1082 H1083 H1084 H1085 H1086 H1087 (H1310) (H1410) (H1510) (H1610) (H1710) (H1810) ‘1’ Address 1 ~ 247 Read remaining time of the step H1081 (1210) Read Response Message CH8 0: stop 1: executing 2: program stops 3: program pauses Positive/negative proportional output Communication specifications Read Command INB NO. of start pattern 0~7 H1122 H1222 H1322 H1422 H1522 H1622 H1722 H1822 NO. of start step 0~7 H1123 H1223 H1323 H1423 H1523 H1623 H1723 H1823 Programmable Parameter Setting: Content Explanation Pattern Pattern Pattern Pattern Pattern Pattern Pattern Pattern 0 1 2 3 4 5 6 7 Max. number of steps in the pattern 0 ~ 7 = N: The pattern executes from step 0 to N. H2068 H2069 H206A H206B H206C H206D H206E H206F Number of cycles of pattern 0 ~ 7 execution 0 ~ 199: The pattern has been executed for 1 ~ 200 times H2070 H2071 H2072 H2073 H2074 H2075 H2076 H2077 NO. of current link pattern 0 ~ 8: 8 refers to end of program; 0 ~ 7 refer to the NO. of next pattern H2078 H2079 H207A H207B H207C H207D H207E H207F Address Default Content Connect maximum 7 DTC2000 or DTC2001 controllers to DTE by using DIN rail. Explanation 2000H ~ 203FH 0 Target temperatures for pattern 0 ~ 7 Pattern 0: 2000H ~ 2007H Unit: 0.1°C 2080H ~ 20BFH 0 Execution time for pattern 0 ~ 7 Pattern 0: 2080H ~ 2087H Time: 0 ~ 900 (Unit: 1 min) 4. Communication format: H03 = read bit data; H06 = write bit data ASCII Mode: Read Command Read Response Message Write Command Write Response Message The content of this instruction sheet may be revised without prior notice. Please consult our distributor or download the most updated version at http://www.delta.com.tw/industrialautomation.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes XMP Toolkit : 3.1-701 Producer : Acrobat Distiller 7.0.5 (Windows) Create Date : 2008:04:10 09:58:10+08:00 Creator Tool : PScript5.dll Version 5.2.2 Modify Date : 2008:04:10 09:58:10+08:00 Format : application/pdf Title : Microsoft Word - 5011671900-DEE0.doc Creator : Document ID : uuid:01d3e4f7-9d74-4c95-b03a-61ecc3689297 Instance ID : uuid:f3633dde-178e-4052-b305-8ef2147dd0ee Page Count : 2 Author :EXIF Metadata provided by EXIF.tools