Deltanode Solutions DMR001 DMR400 Series Repeater Unit User Manual

Deltanode Solutions AB DMR400 Series Repeater Unit

user manual

Download: Deltanode Solutions DMR001 DMR400 Series Repeater Unit User Manual
Mirror Download [FCC.gov]Deltanode Solutions DMR001 DMR400 Series Repeater Unit User Manual
Document ID4108829
Application ID4xWnpmeTNp2Ar+ObrvB+ug==
Document Descriptionuser manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeYes
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize158.99kB (1987434 bits)
Date Submitted2018-12-18 00:00:00
Date Available2018-12-18 00:00:00
Creation Date2018-10-05 11:03:53
Producing SoftwareAdobe PDF Library 11.0
Document Lastmod2018-12-18 08:24:23
Document Titleuser manual
Document CreatorAcrobat PDFMaker 11 for Word
Document Author: Anders Sikvall

DeltaNode Solutions
DMR USER MANUAL
Copyright © 2016 DeltaNode® Solutions Ltd. Sweden
DELTANODE DMR USER MANUAL
Contents
Contents
Introduction ........................................................................................................................................... 2
DMR Operational Description ................................................................................................................ 2
DMR Specifications ................................................................................................................................ 3
Installation guidelines ............................................................................................................................ 4
4.1
Health and Safety .................................................................................................................................4
4.2
Installing the DMR Repeater Unit ................................................................................................... 6
4.2.1
Antenna Connections ............................................................................................................ 7
4.2.2
Power AC .....................................................................................................................................8
DMR Repeater Commissioning ....................................................................................................................9
5.1
Commissioning using Remote Gateway (RGW) .............................................................................. 9
5.2
Repeater commissioning locally ....................................................................................................... 13
5.2.1
Login .................................................................................................................................... 13
5.2.2
Home page........................................................................................................................... 13
5.2.3
RF Config .............................................................................................................................. 14
5.2.4
Advanced RF Config ............................................................................................................. 15
5.2.5
RF Status .............................................................................................................................. 16
5.2.6
Software .............................................................................................................................. 17
5.2.7
Notepad ............................................................................................................................... 18
5.2.8
Access .................................................................................................................................. 18
5.2.9
Communication ................................................................................................................... 19
5.2.10
Alarms .................................................................................................................................. 20
5.2.11
Hardware ............................................................................................................................. 22
5.2.12
Advanced ............................................................................................................................. 22
©DeltaNode Solutions 2016
Revision 16-02
DELTANODE DMR USER MANUAL
Introduction
This document contains quick guidelines on how to operate the DeltaNode DMR Repeater family
and how to install, commission and maintain a Repeater unit.
The Rack Mount Repeater - DMR 400 Series is a medium power repeater for 19” rack mounting. It is
developed for use in moving environments like trains and ships but can also be used in fixed multiband
and multi operator indoor coverage solutions.
The DMR Repeater consists of a 19’’ Rack chassis, one or more Radio Frequency Unit (RFU)s, and a
Power Supply Unit (PSU).
Standalone repeater applications can also be modified and used in the fiber DAS systems where base
stations are not available for signal feeding to the system. In such cases DMR repeater is modified
and equipped with a Fiber optical interface (FOI) inside the chassis.
DMR Operational Description
DeltaNode DMR 400 repeater series is a medium power radio repeater used in 19 inch rack mounted
applications. The extremely light weight, convection fan cooled chassis secures the high quality
performance in almost any environment.
DMR400 repeater can operate in the stand alone applications as well in the fiber fed DAS systems where
the repeaters are used for off air feeding of the DAS network where Base stations are not available.
DMR400 Repeater unit series exists in a number of frequencies and system depended variants and
rackmount chassis consists of following parts:
•
•
•
•
Power supply Unit (PSU)
Internal Duplex Filters (DPX) filtering Uplink and Downlink frequencies and necessary RF
combiners depending on the Remote Unit configuration.
Band selecting Repeater board.
Optional- Remote Gateway unit (called RGW) used for remote access/configuration and alarm
supervision
User has the possibility to set the following parameters in the Repeater unit via web based GUI
application:
•
•
•
•
•
Gain Values (UL & DL)
Bandwidth (UL&DL)
ALC threshold (UL & DL)
Self-oscillation protection
Gain Link symmetry-Gain trail (UL&DL)
©DeltaNode Solutions 2016
Revision 16-02
DELTANODE DMR USER MANUAL
DMR Specifications
GENERAL SPECIFICATIONS
Gain
50 - 80
dB in 1dB steps
Noise Figure
<5
dB
Delay
<6
µs
Power Supply (optional)
Mains
12 - 30
VDC
Power Supply
Mains
85 – 264
VAC or VDC
Power Consumption DC
12-28 V
< 35
Dimensions
WxDxH
10 TE x 220mm x 3U
Weight (Module)
< 0,7
Kg
Weight (Frame)
Kg
Operating Temperature
-25 - +55
ºC
Casing
IP42
Environmental standard
50155
Safety standard
IEC60950
EMC standard
EN50121-3-2
Vibration and shock standard
EN50155
EN61373
AVAILABLE PRODUCTS, AMERICAN CELLULAR
Product
System
UL Frequency
MHz
DL Frequency
MHz
Pout UL/DL,
dBm
Standard
DMR404
700 UC
776 - 788
746 - 758
25
FCC
DMR405
700 LC
698 - 716
728 - 746
25
FCC
DMR407
iDEN
806 - 824
851 - 869
25
FCC
DMR408
Cellular
824 - 849
869 - 894
25
FCC
DMR419
PCS1900
1850 - 1915
1930 - 1995
25
FCC
DMR420
AWS
1710 - 1755
2110 - 2155
25
FCC
Note for Canada: DMR 404 700 UC Frequency is UL 777-787 MHz and DL 746-756 MHz
©DeltaNode Solutions 2016
Revision 16-02
DELTANODE DMR USER MANUAL
Installation guidelines
4.1
Health and Safety
DeltaNode Repeater system is an advanced system and should be handled by skilled staff. DeltaNode
is offering training of installation service providers in the case where this is necessary.
Read all available documentation and warnings before handling the
equipment! Equipment failures due to improper handling are normally not
covered by the product warranty!
Respect all warning signs on the equipment and in the documentation. Make
sure to only operate the equipment on frequencies allowed to use. Do not
modify the equipment! The equipment may from case to case contain a Class
3B laser and the equipment is Class 1. Never look into the Laser beam directly
or indirectly, it is strong invisible light and may cause serious damage to human
eyes!
Always use protective hat on fiber (if used in the application) and connector end when fiber is
removed from socket! Always clean socket and connector after a fiber has been removed before you
re-attach it again!
WARNING
This is NOT a consumer device.
It is design for installation by FCC LICENSEES and QUALIFIED INSTALLERS. You MUST have an
FCC LICENSE or express consent of an FCC licensee to operate this device. Unauthorized use
may result in significant forfeiture penalties, including penalties in excess of $100,000 for
each continuing violation.
WARNING: This is NOT a CONSUMER device. It is designed for installation by an installer
approved by an ISED licensee. You MUST have an ISED LICENCE or the express consent of an
ISED licensee to operate this device.
AVERTISSEMENT : Ce produit N’EST PAS un appareil de CONSOMMATION. Il est conçu pour
être installé par un installateur approuvé par un titulaire de licence d’ISDE. Pour utiliser cet
appareil, vous DEVEZ détenir une LICENCE d’ISDE ou avoir obtenu le consentement exprès
d’un titulaire de licence autorisé par ISDE.
©DeltaNode Solutions 2016
Revision 16-02
DELTANODE DMR USER MANUAL
Keep passwords and other operational information away from unauthorized
personnel!
•
DeltaNode Repeater system is an advanced technology system and
should be handled by FCC Licensee or FCC approved staff.
•
Read all documentation and warnings before handling the equipment.
•
Obey all warning signs on the equipment and in documentation.
•
The equipment may
get
hot
during
operation,
do
not
operate outside permitted temperature range and keep away from
heat sensitive material!
•
The equipment contains ESD sensitive components. Open the
equipment ONLY in a safe location designed for handling ESD
products and use grounding devices! Opening the unit is not intended
for field maintenance!
•
The equipment contains ESD sensitive components. If not handled
with care critical components may be damaged or destroyed. To
avoid any damage due to ESD standard ESD precautions shall be
used when handling the equipment.
•
The product transmits RF signals keep away from Antennas and
other radiating devices.
•
Repeaters generate radio signals which are transmitted by the
connected antennas. Installations should always be done so
that the radiation exposure doesn’t exceed the recommendation
set up by local authorities.
•
Consult a FCC licensee or other applicable regulation body for
details on RF requirements and safety issues on RF!
•
Electrical installation shall be done in accordance with local safety
regulations and laws.
•
Make sure to use the equipment only in its intended
applications and on the allowed frequencies.
•
Avoid overheating by avoiding sunlight exposure!
©DeltaNode Solutions 2016
Revision 16-02
DELTANODE DMR USER MANUAL
4.2
Installing the DMR Repeater Unit
The DMR Chassis is a medium power repeater designed for 19” rack mounting. The Chassis is secured
to the rack by four screws.
The chassis of the repeater should be grounded to a potential bar or safety grounding bar when
operated.
All electrical installations should be done by an FCC Licensee or/and a
certified electrician only!
RF Exposure Warning/Avertissement d'exposition RF
The DMR404, DMR405, DMR408 DL antenna(s) shall be installed to provide a separation distance of at
least 7.5 m from nearby persons and the maximum DL antenna gain is 37 dBi for DMR404, DMR405 and
34 dBi for DMR408.
The DMR404, DMR405, DMR408 UL antenna(s) shall be installed to provide a separation distance of at
least 7.5 m from nearby persons and the maximum UL antenna gain is 37 dBi for DMR404, DMR405 and
34 dBi for DMR408.
The DMR419, DMR420 DL antenna(s) shall be installed to provide a separation distance of at least 5.5 m
from nearby persons and the maximum DL antenna gain is 37 dBi.
The DMR419, DMR420 UL antenna(s) shall be installed to provide a separation distance of at least 0.2 m
from nearby persons and the maximum UL antenna gain is 8 dBi for DMR419 and 5 dBi for DMR420.
L'antenne (s) DMR404, DMR405, DMR408 DL doit être installée pour fournir une distance de séparation
d'au moins 7,5 m des personnes voisines et le gain d'antenne DL maximum est 37 dBi pour DMR404,
DMR405 et 34 dBi pour DMR408. les antennes DMR404, DMR405, DMR408 UL doivent être installé pour
fournir une distance de séparation d'au moins 7,5 m des personnes voisines et le gain d'antenne UL
maximal est 37 dBi pour DMR404, DMR405 et 34 dBi pour DMR408. l'antenne (s) DMR419, DMR420 DL
doit être installée pour fournir une distance de séparation d'au moins 5,5 m de n et le gain maximal de
l'antenne DL est de 37 dBi. l'antenne (s) DMR419, DMR420 UL doit être installée pour fournir une
distance de séparation d'au moins 0,2 m des personnes voisines et le gain d'antenne UL maximal est de
8 dBi pour DMR419 et 5 dBi pour DMR420.
The number of bands supported by the DMR Repeater unit will determine how many RFUs are installed in
the chassis. The Chassis is mounted in the rack as shown in figure 1.
©DeltaNode Solutions 2016
Revision 16-02
DELTANODE DMR USER MANUAL
Figure 1. DMR Rack Mounted Chassis
©DeltaNode Solutions 2016
Revision 16-02
DELTANODE DMR USER MANUAL
4.2.1
Antenna Connections
Connectors and connections of the DMR RFU are shown in figure 2.
Service and Donor Antenna jumpers are connected to the SMA connectors on the RFU.
Figure 2. Connections on the RFU
If a DMR repeater unit is used for feeding the fiber optic DAS system where a base station is not
provided, then the fibers should be connected to an optional Fiber-Optic Interface (FOI) Unit. The FOI
would then be connected to the RFU with coax cable.
©DeltaNode Solutions 2016
Revision 16-02
DELTANODE DMR USER MANUAL
4.2.2
Power AC
All electrical installations should be done by an FCC Licensee or/and a
certified electrician only!
WARNING
This is NOT a consumer device.
It is design for installation by FCC LICENSEES and QUALIFIED INSTALLERS. You MUST have an
FCC LICENSE or express consent of an FCC licensee to operate this device. Unauthorized use
may result in significant forfeiture penalties, including penalties in excess of $100,000 for
each continuing violation.
WARNING: This is NOT a CONSUMER device. It is designed for installation by an installer
approved by an ISED licensee. You MUST have an ISED LICENCE or the express consent of an
ISED licensee to operate this device.
AVERTISSEMENT : Ce produit N’EST PAS un appareil de CONSOMMATION. Il est conçu pour
être installé par un installateur approuvé par un titulaire de licence d’ISDE. Pour utiliser cet
appareil, vous DEVEZ détenir une LICENCE d’ISDE ou avoir obtenu le consentement exprès
d’un titulaire de licence autorisé par ISDE.
Connectors and connections of the DMR PSU are shown in figure 3.
Figure 3. DMR Power Supply Unit
©DeltaNode Solutions 2016
Revision 16-02
DELTANODE DMR USER MANUAL
5 DMR Repeater Commissioning
After the successful mounting installation and powering of the DMR Repeater, user can now start
commissioning the Repeater unit.
Accessing the DMR Repeater units is through the Remote Station Gateway (RGW).
Login and access information such as username and passwords are provided separately by DeltaNode
application engineers.
5.1
Commissioning using Remote Gateway
(RGW)
DeltaNode DMR Repeater units are equipped with an RGW. The RGW is basically a PC/server used
for handling multiple units, alarm management, remote access, commissioning and configurations.
Follow the steps below to set up the repeater network. RGW uses a secure protocol and its IP is by
factory default set to use 192.168.0.2 IP address.
After configuring the PC to use the static IP, open the Web browser and enter the following:
https://192.168.0.2
Log into the RGW with the username and password provided by DeltaNode application engineering.
When logged in, navigate to the configuration menu and put the managed repeater unit into the
DNS of the RGW. See pictures below for reference.
©DeltaNode Solutions 2016
10
Revision 16-02
DELTANODE DMR USER MANUAL
When in configuration menu, click on the DLR/DMR/DHR- xxx option. Move the managed
DLR/DMR/DHR unit from NOT USED window to DLR/DMR/DHR- xxx in the system window and
press Submit.
©DeltaNode Solutions 2016
10
Revision 16-02
DELTANODE DMR USER MANUAL
Now the managed Repeater unit has been added to the RGW DNS.
Navigate to the Network views menu and log into the managed repeater unit by clicking on it.
See picture below for reference.
©DeltaNode Solutions 2016
11
Revision 16-02
DELTANODE DMR USER MANUAL
When logged into the managed repeater, the user can now begin with commissioning of the
managed repeater unit.
©DeltaNode Solutions 2016
12
Revision 16-02
DELTANODE DMR USER MANUAL
5.2
Repeater commissioning locally
5.2.1
Login
Log into the RGW with the username and password provided by DeltaNode application engineering.
5.2.2
Home page
When logged into the repeater, home page is displayed, showing the factory default name of the
repeater, which is basically a unique MAC ID of the actual repeater, article and serial number, RF state
(OFF/ON), and the current output power of the repeater. On the left hand side are the different
configuration menu´s.
©DeltaNode Solutions 2016
13
Revision 16-02
DELTANODE DMR USER MANUAL
5.2.3
RF Config
RF Config menu contains configuration fields for setting the Gain, ALC level, frequency band and the
bandwidth of the actual DMR Repeater unit.
Gain and ALC level can be set for Downlink and Uplink separately. The resolution in setting is
adjustable by the 0, 1 dB.
As mentioned the DMR Repeater unit has the adjustable bandwidth. User can set the Downlink start
and stop frequency path. The uplink path uses a fix duplex distance.
The threshold for the Automatic Level Control (ALC) is set in dBm for downlink and uplink
respectively. The ALC feature controls the gain of the repeater so that the output power never ends
up in exceeding the actual set level of the output power.
When changing any parameters a submit button must be pressed in order to send the data to the
repeater. Get button reads current set parameters.
If a different parameter (other than the specified validation range) is entered and submitted, an
Error message will be displayed on the right hand side of the configuration fields. Error message will
even show the valid range of the actual parameter.
©DeltaNode Solutions 2016
14
Revision 16-02
DELTANODE DMR USER MANUAL
5.2.4
Advanced RF Config
Advanced mode in RF config menu gives user a possibility to control and fine tune the frequency
band edges, set up link symmetry, and self-oscillation protection.
Band edges control gives user a possibility to fine tune the set band width with 0-100 kHz up or
down of the actual set frequency band.
Link symmetry is a function that is mainly developed for usage in moving application setups, like intrain, boats for example. What is does basically is that UL gain is controlled by the DL gain. When this
feature is activated, the repeater will reduce the gain in UL as in DL with the same symmetrical
pattern. The UL gain is determined by the actual automatically controlled gain used in DL. The
originally set gain difference between Uplink and Downlink is kept as originally set.
Link symmetry feature is used to minimize the amount of Noise level to the BTS and is developed
mainly for moving applications as mentioned above such as trains, boats for example when/if the
signal from the BTS fluctuates.
©DeltaNode Solutions 2016
15
Revision 16-02
DELTANODE DMR USER MANUAL
Self-oscillation protection is a function for detection of eventual issues/problems related to the
Antenna isolation between Service and Donor Antenna´s. In case of low isolation between the two
antennas (Service & Donor) the repeater will begin to self-oscillate in the usual manner, but
however self-oscillation protection in this case will immediately intervene and lower the gain to a
safe level equal to the isolation minus the stability margin. There are separate settings for UL and DL
respectively;
• ON/OFF
• Stability margin. The value set of how much lower the gain should be than the calculated
isolation in case of issues with the isolation between the antennas. Range of this value is
from 0.0 – 20 dB.
• Recovery time. This is the time limit before the repeater tries to reset the gain to the
originally actual set gain in RF config. Range for the recovery time is between 30 – 86400
seconds.
• Recovery margin. Set value of gain level above the actual set gain (specified in RF config) that
is used when the repeater recovers after the Recovery time. Range is between 0.0 – 20.0 dB.
5.2.5
RF Status
Generally this menu gives a current status overview for both of the links in the repeater.
Start and stop frequency of both UL and DL are displayed in the firs field as seen in above screen
shot.
Set gain is gain value defined and set by the user. Max gain is the parameter that ALC and other
algorithms, such as the link symmetry feature and antenna oscillation detection, defines/sets is the
current maximum gain of the repeater.
For example, if the antenna oscillation detection algorithm detects antenna isolation issues, Max gain
will be automatically be reduced to a new calculated value. The operation is performed as Antenna
isolation minus set stability margin, which in that case is lower than the set gain.Gain field reflects the
actual gain value set by the user.
If by any chance antenna isolation is an issue while commissioning for example, the field for antenna
isolation will display a certain value measured in dB, and the alarm will be generated. Gain will be
automatically reduced with a certain margin in respect to the Antenna isolation.
For example, if displayed Antenna isolation value is >90dB, then there should be no problem.
©DeltaNode Solutions 2016
16
Revision 16-02
DELTANODE DMR USER MANUAL
Automatic Level Control (ALC) threshold are also displayed and shown in tenths of a dBm. If the set
gain differs from the Max gain for example, this a sign that the ALC is active.
Output power field is displaying RMS power of the repeater measured at the antenna port. Different
modulation waveforms might have a slight impact on the measured value at the antenna port.
User has a possibility also to set up a periodic mode. The window will collect and update the data
displayed every two seconds.
5.2.6
Software
Software menu displays the actual application SW version, fallback application, boot loader version,
serial and article numbers, dates of manufacturing of the unit and its board units used in the actual
repeater product.
When logged in Extended user mode, there are allowed possibilities for Software upgrades, changing
of current application versions, and Reboot option. All actions such as SW upgrades and application
version swap require a command Set which must be followed by a reboot of the repeater in order for
the changes to properly apply.
©DeltaNode Solutions 2016
17
Revision 16-02
DELTANODE DMR USER MANUAL
5.2.7
Notepad
Notepad menu is basically a small scratch pad for text. It is stored in a non-volatile memory. It is
meant to be used as a feature to enter notes about the installation, repeater unit, commissioning
etc. Maximum allowed character number is 255.
5.2.8
Access
In Access menu, user has the possibility to define other passwords for the 2 different level accesses,
Extended and Normal.
When using the Extended level access, there a number of extra parameters and features displayed
and allowance for change. Extended level can be explained as administrator access level, while the
Normal access level can be defined as a light version access level.
©DeltaNode Solutions 2016
18
Revision 16-02
DELTANODE DMR USER MANUAL
5.2.9
Communication
Communication menu contains a number of settings the user has a possibility to define the
communication with the repeater. Ethernet IP addresses, MAC ID are displayed.
User has three options for the IP configuration settings.
•
•
•
Static- IP address that is manually defined by the user.
Default- IP address is set to the factory default address, 192.168.0.202
Automatic. IP address is provided by a DHCP server. This option is used only when the
Remote Gateway (RGW) is optionally used in the actual repeater.
User has a possibility to change the hostname and the Unit ID of the repeater. Unit ID is the name of
the repeater seen in the web interface.
This change must be manually set which follows by a reboot command in order for the change to
take place.
©DeltaNode Solutions 2016
19
Revision 16-02
DELTANODE DMR USER MANUAL
5.2.10
Alarms
Alarm log clearly displays all alarm events in the repeater. The log itself is located in volatile memory
and is cleared every time the repeater is restarted/ rebooted.
There are three levels of severity defined in the repeater.
•
•
•
Warning
Error
Critical
All alarms can be forwarded to external alarm receiver. In order to forward the alarms from the
repeater, syslog UDP port 514 must be used and the correct IP address of external receiver must be
defined. This change as every other mentioned in previous chapters must be manually Set and the
repeater must be rebooted in order for the changes to apply.
The receiver IP address might be changed automatically by the DHCP server if a Remote Gateway
(RGW) is used.
In the alarm menu is also a feature called advanced alarm config, where user has the possibility
define the alarm power levels of UL and DL respectively, and the time out function for these. Further
on the user has possibility to define the ALC gain reduction thresholds.
In case of where external alarm relay is used in combination with the repeater the user has the
possibility to define own descriptions of External alarms generated by the repeater.
User can even generate the Test Alarm in order to test either External Alarm functionality or alarm
forwarding feature.
There are even some cosmetic possibilities like LED intensity and LED style available for user to
change if required.
©DeltaNode Solutions 2016
20
Revision 16-02
DELTANODE DMR USER MANUAL
©DeltaNode Solutions 2016
21
Revision 16-02
DELTANODE DMR USER MANUAL
5.2.11
Hardware
Hardware menu contains internal hardware test points like different driver and synth voltages,
temperatures, etc. This menu is mainly helpful for the advanced users when troubleshooting for
example.
5.2.12
Advanced
The Advanced menu displays DAC (Bit) hardware values. It is not of much interest for the normal use.
As Hardware menu described above, this is mainly used for the troubleshooting and reference for the
advanced users developers and RMA personnel.
©DeltaNode Solutions 2016
22
Revision 16-02
DELTANODE DMR USER MANUAL
©DeltaNode Solutions 2016
23
Revision 16-02

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Author                          : Anders Sikvall
Company                         : 
Created                         : D:20160202
Create Date                     : 2018:10:05 11:03:53-04:00
Last Saved                      : D:20180722
Modify Date                     : 2018:12:18 08:24:23-06:00
Source Modified                 : D:20181005150331
Has XFA                         : No
Language                        : EN-US
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.4-c006 80.159825, 2016/09/16-03:31:08
Metadata Date                   : 2018:12:18 08:24:23-06:00
Creator Tool                    : Acrobat PDFMaker 11 for Word
Document ID                     : uuid:7b99a6bd-e355-4bcf-aa88-fa0b4dc0cd62
Instance ID                     : uuid:a584c11d-bd23-4a23-81e3-8080188317db
Subject                         : 3
Format                          : application/pdf
Creator                         : Anders Sikvall
Producer                        : Adobe PDF Library 11.0
Page Layout                     : OneColumn
Page Count                      : 25
EXIF Metadata provided by EXIF.tools
FCC ID Filing: V5FDMR001

Navigation menu