1.0 Description
The DS160/161 is a passive-infrared (PIR) detector designed for Request
to Exit (REX) interior applications.
The DS160/161 is UL Listed as an access control device under the UL
294 Standard and is listed for Class I for UL Canada under ULC-S319
when it is connected to a UL approved access control system. For C-UL
listed installation applications, the REX detector shall be connected to
ULC-S319 listed compatible devices (i.e. control units, power supply and
locks).
The technology designed into the DS160/161 is based on the principal
that all objects emit infrared energy. The warmer an object is, the more
infrared energy emitted. Its PIR technology allows the DS160/161 to
detect the change in infrared energy that occurs when a person passes
through its field of view.
The DS160/161 has features such as Sequential Logic Input (SLI) to
eliminate unauthorized entry. SLI allows you to arm the detector using any
dry contact device, such as a second detector, card reader, or the access
control system. This provides better control for this type of application.
A built-in sounder can be automatically activated if the door is propped
open. The sounder can be controlled from any dry contact device. The
DS160/161 detection pattern provides dense C-shaped coverage ideal for
most REX applications. In addition, complete pattern control allows it to be
adjusted to a single zone or placed over a doorknob, for example. There
are fifteen possible coverage patterns to accommodate most applications.
This, combined with the ability to monitor the door and intelligently control
the lock, adds considerable security to these types of applications.
The DS160/161 uses Motion Analyzer II signal processing to help prevent
false activation due to environmental conditions. The relay output consists
of two Form “C” contacts that can be adjusted to latch from approximately
0.5 to 64 sec. The latch time features two modes of operation, resettable
(where the relay timer will not time out as long as someone is in the field
of view) and non-resettable (where the relay will remain latched for a fixed
period of time). The relay can also be programmed to fail safe or fail
secure in the event of power loss.
The DS160/161 provides one set of relay contacts specially protected
from EMF (voltage) spikes caused by connecting to inductive loads.
The DS160/161 may either be ceiling or wall mounted, and its pattern may
be aimed and/or masked for more effective use based upon installation
needs. It is not designed as a primary means of exit for emergency egress
applications.
The DS160/161 is available in a light grey (DS160) or a black (DS161)
enclosure along with an optional trim plate (light gray TP160 or black
TP161) that can cover a single gang box. Panic hardware must be used
with this or any other egress device.
Figure 1: Detector Component Locations
Wire
Terminals
Sounder
Sounder Volume Control
DIP Switches
Tamper Switch
LED
Lens Lock-Down Screw
O
N
1 2 3 4 5 6 7 8 9 10
2.0 Installation
1. Remove the cover using a small flat blade screwdriver.
Figure 2: Cover Removal
Insert screwdriver
here
Bottom
of
unit
2. Rotate the detector clockwise to remove it from the base.
Figure 3: Detector Removal
R
o
t
a
t
e
3. Select a mounting location.
Figure 4: Mounting Locations
Push to Exit
Alarm will Sound
Push to Exit
Alarm will Sound Push to Exit
Alarm will Sound
Push to Exit
Alarm will Sound
Above the
Door On the Ceiling Above
Double Doors
Before you mount the unit, review Section 6.0 Coverage
Patterns on page 6 for more information on the placement
and location of the DS160/161.
4. Route the wiring through the base before mounting the base to the
wall or ceiling. Refer to Step 5 on page 2 when using the optional
trim plate (TP160 or TP161).
Figure 5: Wire Routing
2 | F01U252567-01 | 9/11 DS160/DS161 Installation Guide © 2011 Bosch Security Systems, Inc.
5. When using the optional trim plate (TP160 or TP161), run the wiring
through the trim plate and into the base before mounting the base
and trim plate onto a single gang electrical box.
Figure 6: Optional Trimplate
DOOR
DOOR
DS160i/DS161i
Optional Trimplate
(TP160/TP161)
Gang box
The arrows on the base indicate its correct mounting
orientation relative to the door.
3.0 Wiring
3.1 Power, Remote Input, Door Contacts, and Tamper
Refer to Table 1 to wire the detector.
Table 1: Terminal Labels and Descriptions
Label Description
- Connect to the negative side of the power supply.
+ Connect to the positive side of the power supply. The
voltage must be between 12-30 Volts DC or AC.
R Terminal R is for Sequential Logic Input (SLI), the keycard
input or for remote control of the sounder. The contact must
be Normally Closed (NC).
Refer to Figure 7 and Section 3.3.5 Sequential Logic Input
on page 4 for more information.
D Terminal D allows the detector to monitor door contacts.
Refer to Sections 3.3.6 and 3.3.7 on page 4 for more
information. If used, these contacts must be Normally
Closed (NC) door contacts. Do not share these contacts
with any alarm systems.
T Normally Closed (NC) tamper contacts.
Figure 7: Sequential Logic Input (SLI)
D
RTT
Before wiring the unit, review Section 3.3 Wiring Examples
on page 2 for more information on the wiring of the
DS160/161.
3.2 Contact Output Wiring
The normal settings of the contact outputs change depending on the
setting of the Relay Mode Switch (S3). Refer to Section 4.3 Relay Mode
(DIP Switch 3) on page 5.
Figure 8: Contact Output Wiring
Fail Safe
(Switch 3 On) Fail Secure
(Switch 3 Off)
Power Off Power Off
Normal (No Motion) Normal (No Motion)
Motion Detected Motion Detected
NO C NC NO C NC NO C NC NO C NC
NO C NC NO C NC
NO C NC NO C NC
NO C NC NO C NC
NO C NC NO C NC
3.3 Wiring Examples
3.3.1 Basic Connection
The basic connection includes the DS160/161, a power supply, and a
magnetic lock. When the sensor sees motion, power is removed from the
magnetic lock. Relay contacts shown with Switch 3 ON (Failsafe Mode)
and Power On.
Figure 9: Basic Connection
© 2011 Bosch Security Systems, Inc. DS160/DS161 Installation Guide 9/11 | F01U252567-01 | 3
3.3.2 Spike Protection
EMF (Voltage) Spike-Protected Relay: Use this relay when
connecting inductive loads to the detector. This relay protects the
detector from inductive loads that might deliver damaging EMF
spikes. No additional spike protection is needed.
Non-EMF (Voltage) Spike-Protected Relay: This relay is best used
for non-inductive loads. When connecting an inductive load that is
not spike-protected, such as a magnetic door lock, to the detector,
use either a bridge rectifier (such as a KBL01) or a diode (such as a
1N4007). Refer to Figure 10 and Figure 11.
UL listed magnetic locks typically are already EMF spike-
protected, and therefore do not require the bridge rectifier
or diode as shown in Figure 10 and Figure 11. Refer to the
magnetic lock’s documentation for more information.
Figure 10: Diode Connection
Figure 11: Bridge Rectifier Connection
Failure to spike-protect the detector can shorten the life of
the relay contacts.
3.3.3 DS160/161 and a Keycard Reader
Normally, this setup is used when a keycard reader is on one side of the
door and the DS160/161 is on the other side. Either swiping a keycard or
a motion detected by the DS160/161 removes power from the magnetic
lock.
For DIP switch settings, refer to Section 4.7 Remote Input Function (DIP
Switches 2, 9, and 10) on page 6.
Figure 12: Keycard Reader Configuration
3.3.4 Direct Sounder Enable
The Direct Sounder Enable setting can be used to activate the DS160/161
sounder from a remote contact. The DS160/161 internal sounder remains
on as long as the external contacts remain open. The sounder input can
come from devices such as a door controller or door contacts. Turning the
sounder on does not affect the relay or relay timer. The direct sounder
input does not remove power from the magnetic lock.
Turning the sounder on does not affect the relay or relay
timer. The direct sounder input does not remove power
from the magnetic lock.
Figure 13: Direct Sounder Enable Configuration
To ensure the best sound quality from the sounder, tighten
all unused terminals on the terminal strip.
4 | F01U252567-01 | 9/11 DS160/DS161 Installation Guide © 2011 Bosch Security Systems, Inc.
3.3.5 Sequential Logic Input
The detector only activates by motion when the Sequential Logic Input
(Terminal R) is open, or for 10 sec after it closes. For example, when a
second detector placed before the DS160/161 activates, and for 10 sec
after it resets, the DS160/161 activates when it detects motion. Any
movement after 10 sec after the contact on Terminal R closes is ignored.
For DIP switch settings, refer to Section 4.7 Remote Input Function (DIP
Switches 2, 9, and 10) on page 6.
Figure 14: Sequential Logic Input Configuration
3.3.6 Door Monitor Contacts (First Option)
In the Monitor Door Contacts Mode, a person entering the field of view of
the detector activates the relay and timer. Door contacts connected to
Terminal D monitor if the door is open or closed. If the door is held open
and the relay timer is in the last 10 seconds of the latch time, the sounder
will turn on. In order for this to work correctly, the latch time must be set
for 16 seconds or greater (refer to section 4.3 on page 5.) The sounder
also activates if the door is opened without first activating the detector or
keycard input. The sounder remains on until the door closes or by
someone moving in the field of view.
For DIP switch settings, refer to Section 4.7 Remote Input Function (DIP
Switches 2, 9, and 10) on page 6.
Figure 15: Door Monitor Contacts Configuration (First Option)
To ensure the best sound quality from the sounder, tighten
all unused terminals on the terminal strip.
3.3.7 Door Monitor Contacts (Second Option)
If the detector is activated but the door is not opened, the relay drops out
after 10 sec. If the detector is activated and the door opens, then closes,
the relay drops out after 2 sec. This prevents unauthorized people from
entering.
In this mode, the REX can be activated by either someone walking in its
field of view or from a remote device if using the R input. If using the R
input to activate the detector, switch 2 should be set in the ON position
(resettable mode).
For DIP switch settings, refer to Section 4.7 Remote Input Function (DIP
Switches 2, 9, and 10) on page 6.
Figure 16: Door Monitor Contacts Configuration (Second Option)
© 2011 Bosch Security Systems, Inc. DS160/DS161 Installation Guide 9/11 | F01U252567-01 | 5
3.3.8 Disabling the Request-to-Exit
The DS160/161 can be disabled by using Terminal R and an external
device such as an access control or burglar alarm system. When the
contact connected to Terminal R closes, the DS160/161 disables after a
10-sec delay. The DS160/161 returns to normal operation as described in
Section 3.3.5 Sequential Logic Input, on page 4, after the contact closes.
Figure 17: Disabling the Request-to-Exit
The NFPA 101 Life Safety Code requires secured doors to
have a “manual release device that shall result in direct
interruption of power to the lock - independent of the
access control system electronics”.
4.0 Switch Settings
You can change the switch settings by sliding the switch to the ON or OFF
position. Refer to Figure 18.
Figure 18: DIP Switch Positions
O
N
1 2 3 4 5 6 7 8 9 10
ON
OFF
4.1 LED Operation (DIP Switch 1)
ON: LED operates normally when motion is detected.
OFF: LED is turned off.
When LED is enabled, it will flash on and off when first
powered up. Once the flashing LED stops, the REX is
ready to be used.
4.2 Timer Reset Mode (DIP Switch 2)
ON: The relay timer starts when the detector sees motion and
restarts if there is additional motion. The relay only drops out when
there is no more motion and the timer expires.
OFF: The relay timer starts when the detector sees motion. It drops
out when the timer runs out, even if the motion continues. If the
motion continues, the timer restarts.
Refer to Section 4.3 Relay Mode (DIP Switch 3) to select the time period.
4.3 Relay Mode (DIP Switch 3)
ON: The relays operate in the Fail Safe Mode. Refer to Section 3.2
Contact Output Wiring, on page 2, for more information.
OFF: The relays operate in the Fail Secure Mode. In the secure
mode, the REX shall be installed in a manner that does not impair
the intended operation of panic hardware used in conjunction with
the REX detector. The Fail Secure Mode must be authorized by your
Local Authority Having Jurisdiction (AHJ). Refer to Section 3.2
Contact Output Wiring, on page 2, for more information.
4.4 Relay Timer (DIP Switches 4, 5, and 6)
Setting Switches 4, 5, and 6 determines the amount of time the output
relays energize (between 0.5 sec and 64 sec) when motion is detected.
Refer to Table 2 to set the relay timer.
Table 2: Relay Timer DIP Switch Settings
Time (sec) Switch 4 Switch 5 Switch 6
0.5 (Default) OFF OFF OFF
1 OFF OFF ON
2 OFF ON OFF
4 OFF ON ON
8 ON OFF OFF
16 ON OFF ON
32 ON ON OFF
64 ON ON ON
4.5 Signal Processing (DIP Switch 7)
The Signal Processing setting determines how sensitive to movement the
detector is.
ON: High sensitivity (REX Mode)
OFF: Low sensitivity (security sensor)
4.6 Door Secure Mode (DIP Switches 8, 9, and 10)
If the detector activates, but the door does not open, the relay drops out
after 10 sec. If the detector activates and the door opens and then closes,
the relay drops out after 2 sec. This prevents unauthorized people from
entering.
To ensure that the Door Secure Mode operates as
expected, set the relay timer (DIP Switches 4, 5, and 6) to
16 sec or longer.
ON: If DIP Switches 8, 9, and 10 are all ON, Door Secure Mode is
enabled. Wire according to the wiring example shown in Section
3.3.7 Door Monitor Contacts (Second Option) on page 4 for door
secure.
OFF: If DIP Switches 8, 9, and 10 are all OFF, Door Secure Mode is
disabled.
6 | F01U252567-01 | 9/11 DS160/DS161 Installation Guide © 2011 Bosch Security Systems, Inc.
4.7 Remote Input Function (DIP Switches 2, 9, and 10)
The Remote Input Function switches determine what the DS160/161 does
when the contact attached to Terminal R is closed.
Keycard Input: An input to the Terminal R activates the detector.
Normally, this is used with a keycard reader outside of the
door/building. The internal sounder does not activate when the
keycard input is selected. The keycard inputs are affected by
Resettable/Non-resettable Mode (Switch 2). The relay remains
activated for as long as the keycard input is closed. The timer starts
when the keycard input is force activated. If Switch 2 is on, toggling
the keycard input again restarts the timer ( the suggested setting).
When Switch 2 is off, toggling the keycard input does not restart the
timer.
Direct Sounder Enabled: The sounder is turned on for long as the
contact on Terminal R is open. It does not affect the relay or timer.
Sequential Logic Input: The detector only activates if the
Sequential Logic Input (Terminal R) is open, or for 10 sec after it
closes again. Movement after 10 sec after the contact on Terminal R
closes is ignored.
Monitor Door Contacts: Door contacts connected to Terminal D
monitor if the door is open or closed. If the detector activates and the
door is open when 10 sec remain on the timer, the sounder turns on.
If the door opens without activating the detector, the sounder turns
on. The sounder remains on until the door closes or the detector
activates. For this feature to work, set the timer a minimum of 16 sec.
Refer to Table 3 to set the remote input function.
Table 3: Remote Input Function DIP Switch Settings
Function Switch 9 Switch 10
Keycard Input OFF OFF
Direct Sounder Enable OFF ON
Sequential Logic Input ON OFF
Monitor Door Contacts ON ON
5.0 Complete the Installation
1. Secure the detector inside the base.
Figure 19: Secure the Detector
Secure by tightening the
lock-down screw.
R
o
t
a
t
e
Rotate the barrel to the
desired location.
2. Adjust the sounder volume.
Figure 20: Sounder Volume
O
N
1 2 3 4 5 6 7 8 9 10
To adjust the volume, turn the Volume Control with a screwdriver.
Turn clockwise to increase the volume, and counterclockwise to decrease.
To test the volume,
turn Switch 10 on
and apply power.
The sounder will turn
on as long as
Terminal R is open.
To ensure the best sound quality from the sounder, tighten
all unused terminals on the terminal strip.
3. Replace the cover and secure with a screw. Use a drill to remove a
screw knockout in the cover only, then start screw and tighten to
secure.
Figure 21: Replace and Secure Cover
Self-Tapping
Screw
(provided)
6.0 Coverage Patterns
The coverage (detection area) of the DS160/161 varies depending on the
mounting height above the floor, angle of the lens, and if the unit is
mounted on a wall above the door or on the ceiling.
The unit can also be masked to allow only some parts of the coverage
pattern to be active.
6.1 Examples
When the unit is mounted on the wall and the lens is pointed straight
down, some detection zones point toward the wall and do not detect
movement.
Figure 22: Coverage Pattern Example 1
Views of coverage pattern with the unit mounted at 7.5 ft
(2.3 m) above the floor with the "eye" pointed straight down.
Zones that are pointed toward the wall are not shown.
Mounted on
wall above door
Mounted on ceiling 2.5 ft
(.75 m) in front of the door
Front View
ALARM WILL
SOUND WHEN
DOOR IS
OPENED
4 ft
(1.2 m)
ALARM WILL
SOUND WHEN
DOOR IS
OPENED
10 ft
(3 m)
Pattern on Floor
2.5 ft
(.75 m)
5 ft
(1.5 m)
Side View
© 2011 Bosch Security Systems, Inc. DS160/DS161 Installation Guide 9/11 | F01U252567-01 | 7
The higher the unit is mounted, the larger the coverage area. Do not
mount the DS160/161 more than 15 ft (4.6 m) above the floor.
Figure 23: Coverage Pattern Example 2
Side view of coverage pattern with the unit mounted at 15 ft
(4.6 m) above the floor with the "eye" pointed straight down
5 ft
(1.5 m) 10 ft
(3 m)
Mounted on
wall above door Mounted
on ceiling
When the DS160/161 is mounted on the wall above the door, you can
move the coverage pattern away from the wall by rotating the detector’s
lens.
6.2 Masking
The DS160/161 is supplied with three masking wedges used to disable
any part of the coverage pattern. Each wedge covers approximately 25%
of the coverage pattern.
Figure 24: Masking Options
Masking
wedge Masking
wedge Masking
wedge Masking
wedge
Masking
wedge
Insert a masking wedge by placing the bottom peg in first. Then press on
the center of the wedge until it snaps into place.
Figure 25: Insert a Masking Wedge
Select a section of the lens to mask
Insert the tab on the end of the wedge
in the hole in one side of the lens
Textured side
facing out
Press here to snap
into place
Remove a wedge by placing the tip of a small screwdriver behind the
wedge and prying it up. Do not scratch the lens when removing the
wedge.
Figure 26: Remove a Masking Wedge
Insert screwdriver behind wedge
Pry up to remove
Up to three masking wedges can be used if you only want to detect in a
very small area, such as around a doorknob or crash bar.
Figure 27: Masking Wedge Usage
ALARM WILL
SOUND WHEN
DOOR IS
OPENED
Masking
wedges
The coverage pattern depends on how high the
DS160/161 is mounted, location of the unit and the position
of the detector lens. If you want a setup as shown above,
mount the DS160/161 just above the door, on the hinge
side, with the lens pointed down and slightly out.
© 2011 Bosch Security Systems, Inc.
130 Perinton Parkway, Fairport, NY 14450-9199 USA
www.boschsecurity.com
F01U252567-01
Installation Guide
9/11
DS160/DS161
Page 8 of
8
7.0 Specifications
7.1 Specifications
Input Power 12 to 30 VDC or VAC
Relay Two Form “C” contact sets rated for 1 A each at
30 VDC or VAC max for resistive loads.
Terminal Strip 26-14 AWG
Sounder Adjustable up to 70 dB at a distance of 10 ft
(3 m).
Temperature -20°F to +120°F (-29°C to +49°C). For UL and
ULC Listed installations, the temperature range is
+32°F to +120°F (0°C to +49°C).
Humidity 0-95% non-condensing
Dimensions
(HxWxD) 1.8 in. x 7 in. x 1.75 in.
(4.5 cm x 17.8 cm x 4.4 cm)
Trim plate (HxW) Optional. TP160 (light gray); TP161 (black)
3 in. x 8.25 in. (7.6 cm x 21 cm)
Current Draw for Fail Safe Mode (DIP Switch 3 ON)
State 12 VDC 30 VDC 12 VAC 30 VAC
No Motion 15 mA 19 mA 29 mA 38 mA
Alarm 23 mA 26 mA 42 mA 51 mA
Alarm and Sounder 65 mA 79 mA 101 mA 147 mA
Current Draw for Fail Secure Mode (DIP Switch 3 OFF)
State 12 VDC 30 VDC 12 VAC 30 VAC
No Motion 5 mA 9 mA 9 mA 20 mA
Alarm 33 mA 37 mA 40 mA 73 mA
Alarm and Sounder 73 mA 95 mA 95 mA 164 mA
7.2 Regulatory Notes
The unit shall be installed in accordance with National Electrical Code
ANSI/NFPA 70 and part 1 of the Canadian Electrical Code CSA C22.1,
Safety Standard for Electrical Installations.
The DS160/161 is not intended to be configured to function as a stand-
alone access control system. Connection to listed (ALVY and/or ALVY7)
compatible control units and locking devices shall be required.
It is intended to be used as an access control Request-to-Exit device only
and not for security function; as such, the DS160 should not be connected
to a burglar alarm system.
The Request-to-Exit device shall not be connected directly to a keypad for
access control function. Connection to a listed compatible access control
system is required.
The DS160/161 was not investigated by UL for special locking
arrangements in accordance with NFPA 101.
The Request-to-Exit detector was tested for UL compliance while powered
by an XF 1640EE transformer made by AmSeco.