DewertOkin HE150 HE150 User Manual 1

DewertOkin GmbH HE150 1

User Manual

HE150 System Quick Guide 23.08.2018                Id-Nr. xxxxx 4.0                       1 / 6   System overview: HE150 / PP1300 / RF-TOUCH / RF-TOPLINE  CAUTION! Electrical components should be connected or disconnected only when the power supply cord is unplugged. CAUTION! There is a delay after the supply voltage is applied before the device actually turns on. Wait at least two seconds before beginning the commissioning.  Components that can be connected: 1.  HE150 2.  PP1300  3.  JLDQ Massage motor 4.  Distribution cable 5.  JLDQ Massage motor 6.  JLDQ Massage motor 7.  JLDQ Massage motor 8.  Distribution cable 1 4 3 7 6 8 2 5 3 7
HE150 System Quick Guide 23.08.2018                Id-Nr. xxxxx 4.0                       2 / 6   HE150  Connection ports and functions  Technical specifications 1.  Cable connection (HE-300 SMPS POWER SUPPLY) 2.  Connection for distribution cable (PP1300 and JLDQ) 3.  Connection for M3  4.  Connection for M4 5.  Connection for massage motor 6.  Multi-function port for accessories 7.  Floor lighting (LED white) /  Reset / Pairing button (Bluetooth® Pairing LED blue) 8.  Floor lighting (LED white) Input voltage  24-29 V DC Current consumption   max. 6.00 A Mode of operation Protection class    III Protection degree    IP20 Length x width x height  196 x 116 x 40 mm  PP1300  Connection ports and functions Technical specifications 9.  Connection socket 10.  Charging socket Output voltage  max. 29.4 V DC Output current  max. 5.00 A Protection degree    IP20 Length x width x height  147 x 77 x 42 mm   1 3 4 5 6 2 8 7 Intermittent duty 2 min. / 18 min. 910
HE150 System Quick Guide 23.08.2018                Id-Nr. xxxxx 4.0                       3 / 6   RF-TOPLINE                    Description of button  Button Function   Note: By pressing the buttons, the lights lit blue Drive (head rest) up: The drive(s) move as long as this button is pressed. Drive (head rest) down: The drive(s) move as long as this button is pressed. Drive (foot rest) up: The drive(s) move as long as this button is pressed. Drive (foot rest) down: The drive(s) move as long as this button is pressed. Drive (head & foot rest) up: The drive(s) move as long as this button is pressed. Drive (head & foot rest) down: The drive(s) move as long as this button is pressed. Memory position 1: The drives move to the saved position. The drives move as long as this button is pressed. Memory position 2: The drives move to the saved position. The drives move as long as this button is pressed. Memory save button: The drives move to their desired positions. Press the memory save button once then press the desired position button within three seconds. The memory position is saved and the floor lighting blinks twice and a “Peep” signal sounds. Floor lighting on/off: Switch the internal and external floor lighting on/off. The floor lighting turns off automatically after 30 minutes. Flashlight on/off: The flashlight is on as long as this button is pressed.  1  Drive M1 up  2  Drive M1 down  3   Drive M2 up  4  Drive M2 down  5  Reset M1 + M2 up  6  Reset M1 + M2 down  7  Memory position 1  8  Memory position 2  9  Memory save button 10  Floor lighting on/off 11  Flashlight on/off 1 + 2  Pairing (first System) 1 + 2  Floor lighting on/off 3 + 4  Pairing (second System) or   Pairing External Power Socket 3 + 4  Switchable power socket  on/off  1 3 5 7 9 2 4 6 8 10 11
HE150 System Quick Guide 23.08.2018                Id-Nr. xxxxx 4.0                       4 / 6   Acknowledgement:  The floor lighting will blink twice and a "peep" tone will    sound to signal the successful completion of the step. 1.  Teach-in for the RF remote or app To start using the RF remote with a Bluetooth® device, the wireless link with the HE150 must first be established. In order to use a Bluetooth® device (a smart phone or tablet) with your system, you will first need to download and install the "OKIN" app for your device. a.  Automatic teach-in   Insert the power plug into a power outlet. The HE150 will be in pairing mode for 120sec which is divided as follows: During the first 60sec, an RF remote can be discovered (the teach-in). During the next 60sec, a Bluetooth® device can be discovered.   The floor lighting and the blue LED only are used for indicator light, the function are display, not for illumination.   The floor lighting and the blue LED are illuminated during this teach-in phase for the RF remote. RF-TOUCH: Press pairing button A in the battery compartment. RF-TOPLINE: Simultaneously press buttons 1 and 2. A successful pairing will be acknowledged.   The floor lighting will switch off after the teach-in process for the RF remote is finished. The blue LED for pairing with a Bluetooth® device starts flashing.   The blue LED switches off when the Bluetooth® pairing process has timed out or when the device has connected successfully. A successful pairing will be acknowledged.  If, during the RF remote's teach-in process, you press any button on an already paired RF remote, then it switches to the Bluetooth® teach-in mode.   If the RF remote or a Bluetooth® device is discovered during the pairing phase, then this pairing mode is automatically ended. The floor lighting and the blue LED switch off.   Repeat the automatic teach-in process. First, remove the plug from the power supply. Then wait 60sec and insert the plug back into the power supply. You can now start the new teach-in process.   When operating a system in parallel, you must execute the teach-in processes for the HE150s sequentially. First, connect the HE150 to the power supply. Then execute the teach-in process for the first RF remote or Bluetooth® device. Then execute the teach-in for the second device.  Note!   Only commission one system at a time. Never configure multiple systems simultaneously     b.  Manuel teach-in  The system must be connected to the power supply.   Quickly press the Reset/Pairing button twice on the HE150 (button 7) or the HE-300 SMPS (button 9). The floor lighting and the green pairing LED will illuminate. The HE150 is now in pairing mode for 120 seconds, which is divided as follows: During the first 60 seconds, an RF remote can be discovered (the teach-in). During the next 60 seconds, a Bluetooth® device can be discovered.   The floor lighting and the blue LED are illuminated during this teach-in phase for the RF remote. RF-TOUCH: Press pairing button A in the battery compartment. RF-TOPLINE: Simultaneously press buttons 1 and 2. A successful pairing will be acknowledged.   The floor lighting will switch off after the teach-in process for the RF remote is finished. The blue LED for pairing with a Bluetooth® device starts flashing.   The blue LED switches off when the Bluetooth® pairing process has timed out or when the device has connected successfully. A successful pairing will be acknowledged.  If, during the RF remote's teach-in process, you press any button on an already paired RF remote, then it switches to the Bluetooth® teach-in mode.   If the RF remote or a Bluetooth® device is discovered during the pairing phase, then this pairing mode is automatically ended. The floor lighting and the blue LED switch off.   When operating a system in parallel, you must execute the teach-in processes for the HE150s sequentially. First, connect the HE150 to the power supply. Then execute the teach-in process for the first RF remote or Bluetooth® device. Then execute the teach-in for the second device.  Note!   Only commission one system at a time. Never configure multiple systems simultaneously
HE150 System Quick Guide 23.08.2018                Id-Nr. xxxxx 4.0                       5 / 6   2.  Execute a reference movement with the HE150 or HE-300 SMPS The referencing must be execute in the following scenarios:   The initial commissioning   A change in hardware   After the battery-powered electrical reset function has been execute. The system has a positional feedback feature. A referencing movement must first be execute before this feature can function properly. Press the Reset/Pairing button on the HE150 (button 7) or the HE-300 SMPS (button 9) until the end position has been reached. A successful pairing will be acknowledged.  3.  Saving the memory positions You can save different memory locations to the "Memory position" buttons (M1, M2 or M3)" as follows:   Move to the desired positions by pressing the movement buttons on the RF remote or app.   Press the "Memory save" button and hold for one second.   Press one of the "Memory position" buttons (M1, M2 or M3) within three seconds. A successful pairing will be acknowledged.   The desired position is now saved to the memory position button (M1, M2 or M3).   You can overwrite the saved memory position at any time by repeating this process.  4.  Resetting the saved positions to the factory default settings The memory positions saved to buttons M1, M2 or M3 can be reset to the factory default as follows:   Press the Memory save button on the RF Touch and hold down for three seconds.   The "Memory position" buttons (M1 M2 and M3) first light up blue and then white.  After about three seconds, the background lighting flashes white once.  Within one second, press and hold the "Floor lighting on/off" button. The successful completion will be acknowledged.  Release the "Floor lighting on/off" button.  5.  Moving two systems in parallel using a sync cable CAUTION!  Only connect the electrical components when the power supply is switched off. Two operating systems can be connected to each other using a sync cable at the multi-function port. In this way, they can be run simultaneously.   Press the Reset/Pairing button on the HE150 to move both systems to their end positions.   Disconnect the power plug on both systems from the power socket.   Connect both systems by connecting the proper synchronous cable to the multi-function port.   Insert the mains plug from both systems into the power socket. Parallel operations are possible as soon as both systems are connected to the power supply.  Parallel mode on: Press the "Parallel mode on/off" button and hold for about three seconds. The blue button illumination will now be lit. The successful completion will be acknowledged.  Parallel mode off: Press the "Parallel mode on/off" button and hold for about three seconds. The blue button illumination will now go off. The successful completion will be acknowledged. Both programmed RF remotes can be used to move the systems. 6.  Moving two systems in parallel using remote radio signals CAUTION!  Only connect the electrical components when the power supply is switched off. Two systems can be moved and operated simultaneously (parallel mode) using one RF remote.   Press the Reset/Pairing button on the HE150 to move both systems to their end positions.   Execute the teach-in process first for system 1 and then for system 2. Note that the teach-in processes are always sequential. The teach-in should never be carried out on two systems at the same time.   The systems are permanently paired together in this mode. The "Parallel mode on/off" button has no function. The teach-in can be execute for a second RF remote in this mode.
HE150 System Quick Guide 23.08.2018                Id-Nr. xxxxx 4.0                         6 / 6    7.  Cleaning and care The system was designed so that it would be easy to clean.   Be sure to unplug the power cord on the power supply before you begin cleaning it!   Clean the system using a dry antistatic cloth. Be sure that you do not damage the connecting cables during the cleaning. 8.  Disposal The system consists of electronic components, cables and metal and plastic parts. You should observe all corresponding national and regional environmental regulations when disposing of the system. The disposal of the product is regulated in Germany by Elektro-G, internationally by the EU Directive 2012/19/EC (WEEE), or by any applicable national laws and regulations. The system should not be disposed of with  normal household waste! FCC Warning / IC Warning  FCC: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Note: Any changes or modifications not approved by the party responsible for compliance could void the user's authority to operate the equipment. IC: This device complies with Industry Canada's licence- exempt RSSs. Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device." Leprésent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio Exempts de licence. L'exploitation est autorisée aux deux conditions suivantes: (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.  DewertOkin GmbH Weststraße 1 32278 Kirchlengern Germany Phone: +49 (0)5223/979-0 Fax: +49 (0)5223/75182 http://www.dewertokin.de  Info@dewertokin.de