DCR8000 SERIES Surface Mounted Door Closer Non Hold-Open Standard:Back Check Power adjustable 1-4 Installation Instructions for PARALLEL ARM (PUSH SIDE) Mounting THIS TEMPLATE COVERS PARALLEL ARM INSTALLATIONS TO 180° OPENINGS. Parallel bracket accessory required and is included. A * ADJUST SPRING TENSION ACCORDING TO THE FOLLOWING CHART 2-3/4(70mm) 2(51mm) 5/16(8mm) DCR8000 3-3/8(85.7mm) Regular Arm installation Closer installs on PULL/HINGE side of door Left hand door shown Right hand door opposite Dimensions are in inches Do not scale drawing OPENING DIM.A DIM.B SIZE : 4 & 5 SIZE : 4 & 5 To 120 10 7/8 (277.8mm) 6 15 16 (176.2mm) 120 -180 8 3/4 (222.2mm) 4 3/4 (120.6mm) INSTALLATION INSTRUCTIONS -55 ( - 25) 1 -8 55-99 (25-455) 2 -4 99-143 (45-65) 3 0 143-187 (65-85) 4 5 Non Hold Open Arm Left Hand Door-RH or Right Hand Reverse -RHR See Page 2 MAX. 13 FULL TURNS FROM MIN. SETTING. Backcheck Range BACKCHECK (INTENSITY) LATCHING SPEED INCREASE DECREASE Never closer this valve completely LATCHING ADJUSTING VALVE CLOSING ADJUSTING VALVE Pull Side of Door CHART TO DETERMINE HAND OF DOOR LEFT HAND DOOR Spring power Adjusting NUT Push Side of Door Push Side of Door THIS IS A RIGHT HAND DOOR index mark L (B) Pull Side of Door THIS IS A LEFT HAND DOOR s L CAUTION!! Do not turn speed adjusting valve more than two(2) full turns counter-clockwise from its factory set position, as two speed adjusting valves could dislodged from the door closer body, resulting in the loss of internal fluid and failure of the device. CLOSING SPEED OPENING CYCLE R s R NOTE Closing arcs("CLOSE"and"LATCH")are controlled by two(2)seperate speed adjusting valves. Adjust the CLOSING speed first and then adjust the LATCHING speed. To increase backcheck intensity, turn valve marked "BC" clockwise. To decrease backcheck intensity, turn valve marked "BC" counter-clockwise. "BC" Adjusting Valve (A) Non Hold Open Arm Left Hand Door-RH or Right Hand Reverse -RHR See Page 4 1. "CLOSING"speed adjustment is accomplished by full rotations of the speed adjusting valve. -Turn the speed adjusting valve CLOCKWISE for a SLOWER CLOSE arc closing speed. -Turn the speed adjusting valve COUNTER-CLOCKWISE for a FASTER CLOSE arc closing speed. 2 "LATCH" speed adjustment accomplished by full rotations of the speed adjusting valve. -Turn the speed adjusting screw CLOCKWISE for a SLOWER latch are closing speed. -Turn the speed sdjusting screw COUNTER-CLOCKWISE for a FASTER Latch arc closing speed. NOTE: These instructions apply only to closers equipped with backcheck RIGHT HAND DOOR index mark Non Hold Open Arm Left Hand Door-RH or Right Hand Reverse -RHR See Page 3 CLOSING CYCLE FACTORY PRESET SIZE 3 OPENING CYCLE 1. Select door opening angle and use dimensions shown above, mark four (4) holes on door for door closer and three(3) holes underside of frame for paralled of bracket. 2. Drill pilot holes in door and frame to #14 all-purpose screws or drill and tap for 1/4-20 machine screws. 3. Mount closer on door using screws provided. SPEED adjusting valve must be positioned away from hinge edge 4. Install parallel Arm Bracket to frame using screws provided 5. Using a wrench on the square shaft at bottom of closer, rotate shaft approximately 45 degree toward hinge of door. Hold and place main arm of shaft on top of closer at proper index mark as illustrated FOR LEFT HAND DOOR "L"(illustration "A"). FOR RIGHT HAND DOOR "L"(illustration "B"). Tighten arm screw with lockwasher securely. 6. Remove arm shoe from fore arm and discard. Install ROD end of forearm to bracket using screw/washer assembly provided. 7. Adjust length of adjustable forearm so that adjustable forearm is parallel to frame. 8. Adjust closing speed of door following instructions as shown Page 1 Parallel Arm Installation Closer installs on PUSH/STOP side of door. CLOSER ADJUSTMENT * NOTE: 9-1/16(230.2mm) Top Jamb Installation Closer Installs on Frame on PUSH/STOP side of door. FULL TURNS ADJUST INCREASE DECREASE Hinge or Pivot Page: 4 INSTALLATION INSTRUCTIONS Hinge Edge of Door B SIZE LBS (KGS) Door Closer Non Hold-Open Standard:Back Check Power adjustable 1-4 Hinge Edge of Door Parallel bracket 3/4(19mm) DOOR WEIGHT MODEL 7/16(11mm) DCR8000 SERIES Surface Mounted Page: 1 DCR8000 SERIES Surface Mounted DCR8000 SERIES Surface Mounted Door Closer Non Hold-Open Standard:Back Check Power adjustable 1-4 Door Closer Non Hold-Open Standard:Back Check Power adjustable 1-4 Installation Instructions forTOP JAMB (PUSH SIDE) Mounting Installation Instructions for REGULAR ARM (PULL SIDE) Mounting A 6-1/2 (165.1mm) * ADJUST SPRING TENSION ACCORDING TO THE FOLLOWING CHART 1-3/4(44.4mm) A * ADJUST SPRING TENSION ACCORDING TO THE FOLLOWING CHART 9-1/16(230.2mm) 3/4(19mm) 1-1/8(28.5mm) 1-3/4(44.4mm) DCR8000 9-1/16(230.2mm) DIM.A To120 120 -180 6-1/2(165.1mm) 4(101.6mm) FULL TURNS ADJUST -55 ( - 25) 1 -8 55-99 (25-455) 2 -4 99-143 (45-65) 3 0 143-187 (65-85) 4 5 * NOTE: FACTORY PRESET SIZE 3 MAX. 13 FULL TURNS FROM MIN. SETTING. 1-3/4(44.4mm) 6-1/14 (158.7mm) 6 1/2(165.1mm) To 120 * NOTE: Left hand door shown Right hand door opposite Dimensions are in inches Do not scale drawing NOTE: these instructions apply only to closers equipped with backcheck To increase backcheck intensity, turn valve marked "BC" clockwise. To decrease backcheck intensity , turn valve marked "BC" counter-clockwise. OPENING CYCLE Backcheck Range BACKCHECK(INTENSITY) INCREASE DECREASE Never close This valve completely -8 -4 99-143 (45-65) 3 0 143-187 (65-85) 4 5 FACTORY PRESET SIZE 3 To increase backcheck intensity, turn valve marked "BC" clockwise. To decrease backcheck intensity , turn valve marked "BC" counter-clockwise. OPENING CYCLE BACKCHECK(INTENSITY) Backcheck Range Increase Decrease Never close this valve completely Top View Typical Insttallation Right Hand Door "BC" ADJUSTING SCREW SPEED ADJUSTING SCREW L s Preload SPEED ADJUSTING SCREW R R s L R SPEED ADJUSTING SCREW R L Preload Page: 2 1 2 Left hand door "BC" ADJUSTING SCREW s -55 ( - 25) 55-99 (25-455) NOTE: These instrucions apply only to closers equipped with backcheck Left Hand Door SPEED ADJUSTING SCREW FULL TURNS ADJUST OPENING CYCLE 1. Select door opening angle and use dimensions shown above, mark four (4) holes on frame for door closer and two (2) holes on door of arm shoe. 2. Drill pilot holes in door and frame for #14 all-purpose screws or drill and tap for 1/4-20 machine screws 3. Install forearm/arm shoe assembly to door using screws provided. 4. Mount closer on frame using screws provided SPEED ADJUSTING VALVE MUST BE POSITIONED TOWARD HINGE EDGE 5, Install main arm to top pinion shaft, perpendicular to door as shown below, Secure tightly with arm screw/washer assembly provided. 6. Adjust length of forearm so that forearm is perpendicular to frame when assembled to preloaded main arm(illustration below). Secure forearm to main arm with screw/washer assembly provided. 7. Snap pinion cap over shaft at bottom of closer. 8. Adjust closing speed of door, following instructions: as shown Page1. Top View Typical Installation Right hand door SIZE MAX. 13 FULL TURNS FROM MIN. SETTING. OPENING CYCLE 1. Select door opening angle and use dimensions shown above, mark four (4) holes on door for door closer and two (2) holes on frame for arm shoe. 2. Drill pilot holes in door and frame for #14 all-purpose screws or drill and tap for 1/4-20 machine screws. 3. Install forearm/arm shoe assembly to frame using screws provided. 4. Mount closer on door using screws provided . SPEED ADJUSTING VALVE MUST BE POSITIONED TOWARD HINGE EDGE 5. Install main arm to top pinion shaft, perpendicular to door as shown below. Secure tightly with arm screw/washer assembly provided. 6. Adjust length of forearm so that forearm is perpendcular to frame when assembled to preloaded main arm (IIlustration below). Secure forearm to main arm with screw/washer assembly provided. 7. Snap pinion cap over shaft at bottom of closer. 8. Adjust closing speed of door, following instructions as shown page 1. LBS (KGS) INCREASE DECREASE 4(101.6mm) 120 -180 INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS DOOR WEIGHT DIM. A OPENING Hinge or Pivot INCREASE DECREASE Right hand door shown left hand door opposite Dimensions are in inches Do not scale drawing 1/2(12.7mm) Preload L Hinge or Pivot OPENING SIZE LBS (KGS) MODEL DCR8000 MODEL 1(25.4mm) 3/4(19mm) DOOR WEIGHT s Preload Page: 3
Source Exif Data:
File Type : AI File Type Extension : ai MIME Type : application/vnd.adobe.illustrator PDF Version : 1.5 Linearized : No Has XFA : No XMP Toolkit : Adobe XMP Core 5.5-c021 79.153613, 2013/07/11-05:21:54 Format : application/pdf Subject : Description : Closers Modified : 2016:06:03 15:09:33Z Title : Dexter DCR8000 RWPA Instructions Size : 546896 Sha 1 : f256cb99b29bcb76d408184b4ae06aae5495ea00 Extracted : 2016:12:07 00:20:40Z Modify Date : 2016:01:08 21:16:13Z Create Date : 2015:10:06 09:51:51Z Metadata Date : 2016:01:08 21:16:13Z Creator Tool : AutoCAD LT 2014 - English 2014 (19.1s (LMS Tech)) Thumbnail Format : JPEG Thumbnail Image : (Binary data 19894 bytes, use -b option to extract) Thumbnail Height : 184 Thumbnail Width : 256 Rendition Class : proof:pdf Document ID : uuid:32efaa1d-81ab-4dfd-8508-89eccb708b9c Instance ID : uuid:134d6b45-a4d2-4c9e-9086-558460031727 Has Visible Transparency : False N Pages : 1 Plate Names : Cyan, Magenta, Yellow, Black Has Visible Overprint : False Max Page Size Unit : Inches Max Page Size W : 16.541667 Max Page Size H : 11.694444 Swatch Group Type : 0 Swatch Group Name : Default Swatch Group Font Name : ArialMT, Arial-BoldMT Font Type : Open Type, Open Type Font Face : Regular, Bold Font Version : Version 5.06, Version 5.06 Font Composite : False, False Font Family : Arial, Arial Font File Name : arial.ttf, arialbd.ttf Producer : pdfplot11.hdi 11.1.18.0 Page Layout : SinglePage Page Mode : UseOC Page Count : 2 Creator : Adobe Illustrator(R) 17.0 For : Swearingen, Kristina, Bounding Box : 69 50 1120 791 Container Version : 11 Creator Version : 18 Keywords : Closers Image Height : 741 Image Width : 1051 Image Size : 1051x741 Megapixels : 0.779EXIF Metadata provided by EXIF.tools