Dickson Industrial Sc3 Users Manual Web
SC3 to the manual d9ea5663-c356-4746-b2ca-05719a1c5a8c
2015-02-04
: Dickson-Industrial Dickson-Industrial-Sc3-Users-Manual-513456 dickson-industrial-sc3-users-manual-513456 dickson-industrial pdf
Open the PDF directly: View PDF .
Page Count: 8
Download | |
Open PDF In Browser | View PDF |
DICKSON Temperature Chart Recorder Operation Contents: Charts & Accessories Product Applications and Useful Features Product Specifications Charts & Accessories Calibrations Operating Instructions / Getting Started Troubleshooting Warranty / Factory Service & Returns Product Specifications SC3 Product Applications & Useful Features DICKSON Calibrations Operating Instructions / Getting Started Troubleshooting Warranty/ Factory Service & Returns Rev. 06/03 Useful Features Charts & Accessories Rugged case ideal for transportation and storage applications F/C Switchable, 24 hour/7 day Switchable Easy user calibration Security slots for recorder security Special ranges for refrigerators, freezers, incubators and ambient conditions Optional tamper seals can be used to insure the integrity of the chart Compact (less than 4” tall/wide) and durable Operates for up to 2 years on a single “AA” battery Direct sensing, no remote probe, compact enough to be placed almost anywhere Product Specifications • • • • • • • • • Product Applications & Useful Features The SC3 sets a new standard for compact recorders while providing the accuracy and resolution required for regulatory compliance and quality control. The reusable SC3 is rugged enough to withstand the rigors of transportation and storage applications. Best of all, its unbeatable low price makes temperature recording affordable for virtually any application. DICKSON Product Applications Calibrations Operating Instructions / Getting Started Troubleshooting Warranty/ Factory Service & Returns Rev. 06/03 DICKSON Product Specifications Product Applications & Useful Features Product Specifications Charts & Accessories Temperature Sensor: Precise spiral wound bi-metallic strip transducer Recorder Accuracy: ±4˚F (±2.5˚C) over full scale Ambient Operating Temperature: -22 to +122˚F (-30 to +50˚C) Response Time: 11 minutes to move 63% of full scale in air moving 5’ per second Temperature Ranges: (˚F or ˚C depending on chart installed) -14 to +32˚F (-25 to 0˚C), +4 to +50˚F (-15 to +10˚C), +22 to +68˚F (-5 to +20˚C), +50 to +96˚F (+10 to +35˚C), +76 to +122˚F (+25 to +50˚C) Recording Time: 24 hour or 7 day Power Supply: Single “AA” battery, up to 2 years average life Resolution: Not less than 1” per +55˚F in 1˚C or 2˚F steps Mounting: Free standing, wall mounted or suspended Chart Size: 3” (75mm) DIA Dimensions: 3.667” x 3.667” x 2.232” (93mm x 93mm x 57mm) Weight: 0.5 lbs. (227 g) Includes: Battery, pen and instruction manual Calibrations Operating Instructions / Getting Started Troubleshooting Warranty/ Factory Service & Returns Rev. 06/03 7 Day °F Chart C302 C304 C320 C306 C308 7 Day °C Chart C310 C312 C318 C341 C316 24 Hour °F Chart C301 C303 C319 C305 C307 24 Hour °C Chart C309 C311 C317 C313 C315 Accessories Order # N300 N400 P222 A715 A711 Product Specifications Description NIST Traceable Calibration 3-pt. (new unit) A2LA Accredited Calibration 3-pt. (new unit) Pens (6 red) Locking Wall Mount Case Waterproof Pouch Product Applications & Useful Features °F and °C Switchable Range -14 to +32°F / -20 to 0°C +4 to +50°F / -15 to +20°C +22 to +68°F / -5 to +20°C +50 to +96°F / +10 to +35°C +76 to +122°F / +25 to +50°C DICKSON Charts Charts & Accessories Calibrations Operating Instructions / Getting Started Troubleshooting Warranty/ Factory Service & Returns Rev. 06/03 N100 - NIST Traceable Calibration 1-Point: Includes documentation to one Dickson pre-selected point on new units only. N400 - Deluxe A2LA Accredited NIST Traceable Calibration 3-Point: ISO Guide 25/A2LA Documentation of 3 pre-selected points of as found data before and after calibration for Dickson temperature and/or humidity instrumentation on new units only. The Importance and Benefits of Regular Calibrations Once you begin to use your precision Dickson instrumentation, regular calibrations are necessary to ensure accurate readings. Product Specifications N995 - NIST User Selected Temperature Points: Documentation of one customer specified point. Should be selected in addition to one of the above calibration options. Product Applications & Useful Features N300 - NIST Traceable Calibration 3-Point: Includes documentation of three Dickson pre-selected points (a high, medium, and low) on new units only. DICKSON Calibration Services - New Units The following Calibration Services are available: N350 - NIST Traceable Calibration 3-Point: Includes documentation of three Dickson pre-selected points (a high, medium, and low) after re-calibration. N995 - NIST User Selected Temperature Points: Documentation of one customer specified point. Should be selected in addition to one of the above calibration options. Why should I return my instrument to Dickson for calibration? Dickson calibrates your instrument at the factory using proprietary production/calibration software that guarantees proper calibration. Fast Service: Our turnaround time is 3 days or less so you receive not only expert service but fast service as well. Easy: We make it easy for you! No phone calls for Return Authorization Numbers are required. We remind you when your instrument is due for calibration. You simply send in the completed Calibration Order Form with your unit for calibration with freight prepaid to Dickson. Rev. 06/03 Warranty/ Factory Service & Returns Our Capabilities Dickson is the first manufacturer of humidity and temperature instrumentation to receive A2LA accreditation. We are also NIST Traceable; our procedures conform to MIS-STD-45662A, ANSI/NCSL 2540-1-1994, ISO/ IEC Guide 25 and ISO10012. We are experts in the manufacture and calibration of humidity and temperature instruments. Troubleshooting How often should I recalibrate my instrumentation? Depending on the environment your instrument is used in and how often it is handled you will want to recalibrate your instrument every 6 to 12 months. Instruments in environments where there are extreme temperatures, wide temperature ranges, humidity or pressure variations, high condensation, dirt, dust and other debris will require calibration at least every 6 months. Instruments that are frequently moved or in locations with heavy machinery that cause vibrations should also be calibrated at least every 6 months. Operating Instructions / Getting Started Why should I recalibrate my instrumentation? Over time dirt, dust and normal handling can throw your precision instrumentation out of calibration. Regular calibrations ensure that you receive the most accurate readings possible. Calibrations N450 - Deluxe A2LA Accredited NIST Traceable Calibration 3-Point: ISO Guide 25/A2LA Documentation of 3 pre-selected points of as found data before and after calibration for Dickson temperature and/or humidity instrumentation. Charts & Accessories N150 - NIST Traceable Calibration 1-Point: Includes documentation to one Dickson pre-selected point after re-calibration. Pen Replacement Product Applications & Useful Features • Place chart on recorder • Set time by inserting a coin into chart hub and turning clockwise until the current hour is referenced to the time index clip. (Time index clip is directly to the right and below the pen tip). • Remove protective pen cap. The chart movement is self-starting and runs continuously. Allow unit to stabilize in environment for 15 minutes. DICKSON Getting Started Slide the used pen cartridge off and slide the new one on. Typical pen life is one year. The battery compartment is located on the back of the recorder. The recorder uses a standard “AAA” battery for up to two years of battery life. Chart Rotation Speed Calibrations The unit has a switchable clock, you can change the speed from a 7 day to a 24 hour rotation and from a 24 hour to a 7 day rotation. Make sure the right chart is selected for your rotation. Simply move the switch located on the back of the unit to the speed that fits your application. Charts & Accessories • Insert new battery with the positive end down Product Specifications Battery Replacement Operating Instructions / Getting Started Troubleshooting Warranty/ Factory Service & Returns Rev. 06/03 Chart Does Not Rotate If the chart is not rotating make sure the center strip of the chart is inserted properly into the black center hub of the recorder making sure the chart is not torn or ripped. If the chart is properly installed and there is still no rotation the clock needs to be replaced, please call customer service for a return authorization number. Product Applications & Useful Features Pen Tension If the pen is not touching the paper, remove red pen and push the metal pen arm down near the middle of the arm. If that does not work unscrew the pen arm from the recorder and bend the pen arm down. Make sure the unit is in a stable environment, replace the pen arm at the same spot from where it was removed. DICKSON Troubleshooting Product Specifications Charts & Accessories Calibrations Operating Instructions / Getting Started Troubleshooting Warranty/ Factory Service & Returns Rev. 06/03 Contact the factory (630-543-3747) for a Return Authorization (RA) Number before returning any instrument. The model number, serial number and a purchase order number will be requested before an RA number is issued. Software Return Policy IMPORTANT-Read your Software License Agreement carefully before installing software. DIckson will accept returns for replacement of defective disks and CDs only. Operating Instructions / Getting Started Customer Satisfaction Dickson takes pride in providing you, the customer, with the highest quality instrumentation. We welcome the opportunity to help you in any way possible. Whether it be a question or a new idea in documentation, the Dickson Company would like to hear your response. Please call our Customer Service Department at 1-800-323-2448 or (630) 543-3747 (in Illinois). Calibrations NOTE: Dickson shall not be liable for consequential or incidental damages resulting from failure or malfunction of its products. Charts & Accessories • Carefully repack the instrument, label the outside of the box with the RA# and return the instrument (freight pre-paid) to Dickson. • All instruments that do not have the RA# clearly marked on the outside of the box will be refused. When returning instruments for credit, please include all accessories in shipment. • Calibration/Freight charges are non-refundable. Product Specifications Factory Service & Returns Product Applications & Useful Features Dickson warrants that the products it sells will be free from defects in material and workmanship under normal use and service for a period of twelve months after delivery. In the event of a claim under this warranty, the product or part must be returned to the factory for repair or replacement (shipping pre-paid) with a Return Authorization Number (see Return Information above). It will be repaired at Dickson’s option without charge. This warranty DOES NOT cover routine calibration, pen, chart and battery replacement. The foregoing warranty and remedy are exclusive and in lieu of all other warranties either expressed or implied. Dickson shall not be liable for consequential or incidental damages resulting from failure or malfunction of its products. Dickson makes no warranty for products not manufactured by it or for any products modified by buyer, or subject to misuse or neglect. DICKSON Warranty Troubleshooting Warranty/ Factory Service & Returns DICKSON 930 South Westwood Avenue Addison, Illinois 60101 Phone: (630) 543-3747 • E-mail: DicksonCSR@dicksonweb.com Rev. 06/03
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : Yes Modify Date : 2003:06:26 10:02:44-05:00 Create Date : 2003:06:18 10:01:15Z Producer : Adobe PDF Library 5.0 Creator : Adobe InDesign 2.0.2 Trapped : False Page Count : 8 Creation Date : 2003:06:18 10:01:15Z Mod Date : 2003:06:26 10:02:44-05:00 Metadata Date : 2003:06:26 10:02:44-05:00 Document ID : adobe:docid:indd:bbabb4d2-a2f5-11d7-bc8e-9d0e6987fdd4 Version ID : 1 Rendition Class : proof:pdf Rendition Of Document ID : adobe:docid:indd:bbabb4d2-a2f5-11d7-bc8e-9d0e6987fdd4 Rendition Of Version ID : 1 Rendition Of Rendition Class : default Format : application/pdf Title : SC3 Web Manual Tagged PDF : YesEXIF Metadata provided by EXIF.tools