Dickson Industrial Sc3 Users Manual Web

SC3 to the manual d9ea5663-c356-4746-b2ca-05719a1c5a8c

2015-02-04

: Dickson-Industrial Dickson-Industrial-Sc3-Users-Manual-513456 dickson-industrial-sc3-users-manual-513456 dickson-industrial pdf

Open the PDF directly: View PDF PDF.
Page Count: 8

DownloadDickson-Industrial Dickson-Industrial-Sc3-Users-Manual- SC3 Web Manual  Dickson-industrial-sc3-users-manual
Open PDF In BrowserView PDF
DICKSON

Temperature Chart Recorder Operation
Contents:

Charts &
Accessories

Product Applications and Useful Features
Product Specifications
Charts & Accessories
Calibrations
Operating Instructions / Getting Started
Troubleshooting
Warranty / Factory Service & Returns

Product
Specifications

SC3

Product
Applications &
Useful Features

DICKSON

Calibrations
Operating
Instructions /
Getting Started
Troubleshooting
Warranty/
Factory Service
& Returns

Rev. 06/03

Useful Features

Charts &
Accessories

Rugged case ideal for transportation and storage applications
F/C Switchable, 24 hour/7 day Switchable
Easy user calibration
Security slots for recorder security
Special ranges for refrigerators, freezers, incubators and ambient conditions
Optional tamper seals can be used to insure the integrity of the chart
Compact (less than 4” tall/wide) and durable
Operates for up to 2 years on a single “AA” battery
Direct sensing, no remote probe, compact enough to be placed almost anywhere

Product
Specifications

•
•
•
•
•
•
•
•
•

Product
Applications &
Useful Features

The SC3 sets a new standard for compact recorders while providing the accuracy and resolution required
for regulatory compliance and quality control. The reusable SC3 is rugged enough to withstand the rigors of
transportation and storage applications. Best of all, its unbeatable low price makes temperature recording
affordable for virtually any application.

DICKSON

Product Applications

Calibrations
Operating
Instructions /
Getting Started
Troubleshooting
Warranty/
Factory Service
& Returns

Rev. 06/03

DICKSON

Product Specifications

Product
Applications &
Useful Features
Product
Specifications
Charts &
Accessories

Temperature Sensor:
Precise spiral wound bi-metallic strip transducer
Recorder Accuracy:
±4˚F (±2.5˚C) over full scale
Ambient Operating Temperature: -22 to +122˚F (-30 to +50˚C)
Response Time:
11 minutes to move 63% of full scale in air moving 5’ per second
Temperature Ranges:
(˚F or ˚C depending on chart installed) -14 to +32˚F (-25 to 0˚C),
+4 to +50˚F (-15 to +10˚C), +22 to +68˚F (-5 to +20˚C),
+50 to +96˚F (+10 to +35˚C), +76 to +122˚F (+25 to +50˚C)
Recording Time:
24 hour or 7 day
Power Supply:
Single “AA” battery, up to 2 years average life
Resolution:
Not less than 1” per +55˚F in 1˚C or 2˚F steps
Mounting:
Free standing, wall mounted or suspended
Chart Size:
3” (75mm) DIA
Dimensions:
3.667” x 3.667” x 2.232” (93mm x 93mm x 57mm)
Weight:
0.5 lbs. (227 g)
Includes:
Battery, pen and instruction manual

Calibrations
Operating
Instructions /
Getting Started
Troubleshooting
Warranty/
Factory Service
& Returns

Rev. 06/03

7 Day
°F Chart
C302
C304
C320
C306
C308

7 Day
°C Chart
C310
C312
C318
C341
C316

24 Hour
°F Chart
C301
C303
C319
C305
C307

24 Hour
°C Chart
C309
C311
C317
C313
C315

Accessories
Order #
N300
N400
P222
A715
A711

Product
Specifications

Description
NIST Traceable Calibration 3-pt. (new unit)
A2LA Accredited Calibration 3-pt. (new unit)
Pens (6 red)
Locking Wall Mount Case
Waterproof Pouch

Product
Applications &
Useful Features

°F and °C Switchable
Range
-14 to +32°F / -20 to 0°C
+4 to +50°F / -15 to +20°C
+22 to +68°F / -5 to +20°C
+50 to +96°F / +10 to +35°C
+76 to +122°F / +25 to +50°C

DICKSON

Charts

Charts &
Accessories
Calibrations
Operating
Instructions /
Getting Started
Troubleshooting
Warranty/
Factory Service
& Returns

Rev. 06/03

N100 - NIST Traceable Calibration 1-Point: Includes documentation to one Dickson pre-selected point
on new units only.

N400 - Deluxe A2LA Accredited NIST Traceable Calibration 3-Point: ISO Guide 25/A2LA Documentation of 3 pre-selected points of as found data before and after calibration for Dickson temperature
and/or humidity instrumentation on new units only.

The Importance and Benefits of Regular Calibrations
Once you begin to use your precision Dickson instrumentation, regular calibrations are necessary to ensure
accurate readings.

Product
Specifications

N995 - NIST User Selected Temperature Points: Documentation of one customer specified point.
Should be selected in addition to one of the above calibration options.

Product
Applications &
Useful Features

N300 - NIST Traceable Calibration 3-Point: Includes documentation of three Dickson pre-selected
points (a high, medium, and low) on new units only.

DICKSON

Calibration Services - New Units

The following Calibration Services are available:

N350 - NIST Traceable Calibration 3-Point: Includes documentation of three Dickson pre-selected
points (a high, medium, and low) after re-calibration.

N995 - NIST User Selected Temperature Points: Documentation of one customer specified point.
Should be selected in addition to one of the above calibration options.

Why should I return my instrument to Dickson for calibration?
Dickson calibrates your instrument at the factory using proprietary production/calibration software that
guarantees proper calibration.

Fast Service: Our turnaround time is 3 days or less so you receive not only expert service but fast
service as well.
Easy: We make it easy for you! No phone calls for Return Authorization Numbers are required. We
remind you when your instrument is due for calibration. You simply send in the completed Calibration
Order Form with your unit for calibration with freight prepaid to Dickson.

Rev. 06/03

Warranty/
Factory Service
& Returns

Our Capabilities
Dickson is the first manufacturer of humidity and temperature instrumentation to receive A2LA accreditation.
We are also NIST Traceable; our procedures conform to MIS-STD-45662A, ANSI/NCSL 2540-1-1994, ISO/
IEC Guide 25 and ISO10012. We are experts in the manufacture and calibration of humidity and temperature
instruments.

Troubleshooting

How often should I recalibrate my instrumentation?
Depending on the environment your instrument is used in and how often it is handled you will want to
recalibrate your instrument every 6 to 12 months. Instruments in environments where there are extreme temperatures, wide temperature ranges, humidity or pressure variations, high condensation, dirt, dust and other
debris will require calibration at least every 6 months. Instruments that are frequently moved or in locations
with heavy machinery that cause vibrations should also be calibrated at least every 6 months.

Operating
Instructions /
Getting Started

Why should I recalibrate my instrumentation?
Over time dirt, dust and normal handling can throw your precision instrumentation out of calibration. Regular calibrations ensure that you receive the most accurate readings possible.

Calibrations

N450 - Deluxe A2LA Accredited NIST Traceable Calibration 3-Point: ISO Guide 25/A2LA Documentation of 3 pre-selected points of as found data before and after calibration for Dickson temperature
and/or humidity instrumentation.

Charts &
Accessories

N150 - NIST Traceable Calibration 1-Point: Includes documentation to one Dickson pre-selected point
after re-calibration.

Pen Replacement

Product
Applications &
Useful Features

• Place chart on recorder
• Set time by inserting a coin into chart hub and turning clockwise until the current hour is referenced to the
time index clip. (Time index clip is directly to the right and below the pen tip).
• Remove protective pen cap. The chart movement is self-starting and runs continuously. Allow unit to
stabilize in environment for 15 minutes.

DICKSON

Getting Started

Slide the used pen cartridge off and slide the new one on. Typical pen life is one year.

The battery compartment is located on the back of the recorder. The recorder uses a standard “AAA”
battery for up to two years of battery life.

Chart Rotation Speed

Calibrations

The unit has a switchable clock, you can change the speed from a 7 day to a 24 hour rotation and from a
24 hour to a 7 day rotation. Make sure the right chart is selected for your rotation. Simply move the switch
located on the back of the unit to the speed that fits your application.

Charts &
Accessories

• Insert new battery with the positive end down

Product
Specifications

Battery Replacement

Operating
Instructions /
Getting Started
Troubleshooting
Warranty/
Factory Service
& Returns

Rev. 06/03

Chart Does Not Rotate
If the chart is not rotating make sure the center strip of the chart is inserted properly into the black center
hub of the recorder making sure the chart is not torn or ripped. If the chart is properly installed and there
is still no rotation the clock needs to be replaced, please call customer service for a return authorization
number.

Product
Applications &
Useful Features

Pen Tension
If the pen is not touching the paper, remove red pen and push the metal pen arm down near the middle of
the arm. If that does not work unscrew the pen arm from the recorder and bend the pen arm down. Make
sure the unit is in a stable environment, replace the pen arm at the same spot from where it was removed.

DICKSON

Troubleshooting

Product
Specifications
Charts &
Accessories
Calibrations
Operating
Instructions /
Getting Started
Troubleshooting
Warranty/
Factory Service
& Returns

Rev. 06/03

Contact the factory (630-543-3747) for a Return Authorization (RA) Number before returning any
instrument. The model number, serial number and a purchase order number will be requested before an RA
number is issued.

Software Return Policy
IMPORTANT-Read your Software License Agreement carefully before installing software. DIckson will accept
returns for replacement of defective disks and CDs only.

Operating
Instructions /
Getting Started

Customer Satisfaction
Dickson takes pride in providing you, the customer, with the highest quality instrumentation. We welcome
the opportunity to help you in any way possible. Whether it be a question or a new idea in documentation,
the Dickson Company would like to hear your response. Please call our Customer Service Department at
1-800-323-2448 or (630) 543-3747 (in Illinois).

Calibrations

NOTE: Dickson shall not be liable for consequential or incidental damages resulting from failure or
malfunction of its products.

Charts &
Accessories

• Carefully repack the instrument, label the outside of the box with the RA# and return the instrument
(freight pre-paid) to Dickson.
• All instruments that do not have the RA# clearly marked on the outside of the box will be refused. When
returning instruments for credit, please include all accessories in shipment.
• Calibration/Freight charges are non-refundable.

Product
Specifications

Factory Service & Returns

Product
Applications &
Useful Features

Dickson warrants that the products it sells will be free from defects in material and workmanship under
normal use and service for a period of twelve months after delivery. In the event of a claim under this
warranty, the product or part must be returned to the factory for repair or replacement (shipping pre-paid)
with a Return Authorization Number (see Return Information above). It will be repaired at Dickson’s option
without charge. This warranty DOES NOT cover routine calibration, pen, chart and battery replacement. The
foregoing warranty and remedy are exclusive and in lieu of all other warranties either expressed or implied.
Dickson shall not be liable for consequential or incidental damages resulting from failure or malfunction of
its products. Dickson makes no warranty for products not manufactured by it or for any products modified by
buyer, or subject to misuse or neglect.

DICKSON

Warranty

Troubleshooting
Warranty/
Factory Service
& Returns

DICKSON

930 South Westwood Avenue
Addison, Illinois 60101
Phone: (630) 543-3747 • E-mail: DicksonCSR@dicksonweb.com
Rev. 06/03



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : Yes
Modify Date                     : 2003:06:26 10:02:44-05:00
Create Date                     : 2003:06:18 10:01:15Z
Producer                        : Adobe PDF Library 5.0
Creator                         : Adobe InDesign 2.0.2
Trapped                         : False
Page Count                      : 8
Creation Date                   : 2003:06:18 10:01:15Z
Mod Date                        : 2003:06:26 10:02:44-05:00
Metadata Date                   : 2003:06:26 10:02:44-05:00
Document ID                     : adobe:docid:indd:bbabb4d2-a2f5-11d7-bc8e-9d0e6987fdd4
Version ID                      : 1
Rendition Class                 : proof:pdf
Rendition Of Document ID        : adobe:docid:indd:bbabb4d2-a2f5-11d7-bc8e-9d0e6987fdd4
Rendition Of Version ID         : 1
Rendition Of Rendition Class    : default
Format                          : application/pdf
Title                           : SC3 Web Manual
Tagged PDF                      : Yes
EXIF Metadata provided by EXIF.tools

Navigation menu