User Guide

Digi TS Family
Digi One TS, Digi One TS Wireless, Digi One RealPort, Digi One RealPort Wireless, PortServer TS 2/4,
PortServer TS 2/4 MEI, PortServer TS 2/4 Wireless, PortServer TS 1/3 + Modem, and PortServer TS 8/16

90000583_A

 Digi International Inc. 2004. All Rights Reserved.
The Digi logo, PortServer, Connectware, Digi One, and RealPort are trademarks or registered trademarks of Digi
International, Inc.

90000583_A

Contents
Chapter 1 Introduction
About This Guide................................................................................... 7
Purpose .............................................................................................................. 7
Audience............................................................................................................. 7
Scope ................................................................................................................. 7

Other Documents in the Library.............................................................7
Quick Start Guide ............................................................................................... 7
Digi Command Reference .................................................................................. 7
RealPort Setup Guides ....................................................................................... 7
Online Help for the Web UI................................................................................. 7

Setup Overview ..................................................................................... 8
Step A: Plan........................................................................................................ 8
Step B: Set Up the Hardware ............................................................................. 8
Step C: Install and Setup Digi Port Authority-Remote ........................................ 8
Step D: Configure an IP Address ....................................................................... 8
Step E: Configure Ports ...................................................................................... 8
Step F: Configure Other Features as Required .................................................. 9

Supported Devices ................................................................................ 9
About Configuration Methods ................................................................ 9
Configure the Digi Device with the Wizard ......................................................... 9
Configure the Digi Device from an Attached Terminal ....................................... 9
Configure the Digi Device from a Telnet Session ............................................... 9
Configure the Digi Device from the Web Interface ............................................. 9
Downloading a Configuration File..................................................................... 10

Accessing the Configuration from the Web Interface ..........................10
Quick Find Table ................................................................................. 10
Chapter 2 Configuring the IP Address
Options for Configuring the IP Address and Mask .............................. 13
Device Support: Digi Port Authority-Remote and ARP-Ping for IP Address
Configuration .................................................................................................... 13

Configuring the IP Address with Digi Port Authority-Remote .............. 14
Assumptions ..................................................................................................... 14
Procedure ......................................................................................................... 14

Configuring the IP Address Using ARP-Ping....................................... 14
Assumptions ..................................................................................................... 14
Procedure ......................................................................................................... 15

Configuring an IP Address using DHCP and RARP............................ 15
About DHCP and RARP ................................................................................... 15
Procedure ......................................................................................................... 15

Accessing the Digi Device ................................................................... 15
Chapter 3 Configuration
Network Settings ................................................................................. 17
Procedure for Using a Name Server ................................................................ 18

Configuring the Serial Ports................................................................. 19

Contents

3

Port Profiles ......................................................................................... 21
RealPort............................................................................................................ 21
Console Management ...................................................................................... 21
TCP Sockets..................................................................................................... 22
UDP Sockets .................................................................................................... 22
Serial Bridging .................................................................................................. 23
Printer ............................................................................................................... 24
Terminal............................................................................................................ 24
Industrial Automation ........................................................................................ 25
Modem Profiles................................................................................................. 25
Modem Emulation............................................................................................. 26
Modem.............................................................................................................. 26
Power Management ......................................................................................... 27
Custom ............................................................................................................. 28

User Configuration............................................................................... 29
Common User Features ................................................................................... 29

Security Configuration .........................................................................30
Procedure ......................................................................................................... 30

System Configuration .......................................................................... 31
PPP Settings .................................................................................................... 31

About Autoconnection .........................................................................33
Configuring a Port for Autoconnection................................................. 33
Configuring a User for Autoconnection................................................ 34
Chapter 4 Setting Up RealPort
About RealPort .................................................................................... 35
What is RealPort?............................................................................................. 35
RealPort Advantages........................................................................................ 35
Configuring the RealPort Software ................................................................... 35

Chapter 5 Special Features: Wireless
Configuration Considerations .............................................................. 37
Using Ethernet.................................................................................................. 37

Chapter 6 Special Features: Embedded Modem
Embedded Modem .............................................................................. 41
Installing the PortServer TS 1/3 + Modem........................................................ 41
Configuring the PortServer TS 1/3 + Modem ................................................... 41

Chapter 7 Special Features: Modem Emulation
Modem Emulation................................................................................ 43
Modem Emulation Cable Signals ........................................................ 44
Scenarios for Modem Emulation ......................................................... 45
Outgoing Modem Emulation Connection .......................................................... 45
Incoming Modem Emulation Connection .......................................................... 45
Modem Emulation Pooling................................................................................ 45
Modem Emulation Bridge ................................................................................. 45

Originating, Answering, and Disconnecting Calls................................ 45
Disconnecting Calls-Digi Device Server ........................................................... 46

Modem Emulation AT Command Set .................................................. 46

4

Contents

S-Registers.......................................................................................... 52
Result Codes .......................................................................................57
Chapter 8 Special Features: Power Over the Serial Ports
Serial Power Feature........................................................................... 59
Configuring RI Power .......................................................................... 59
RI Power In....................................................................................................... 59
RI Power Out .................................................................................................... 60

Configuring DTR Power....................................................................... 60
Power Out......................................................................................................... 60

Serial Power Table .............................................................................. 61
Chapter 9 Special Features: IA (Industrial Automation)
Configuring Industrial Automation with Modbus .................................. 63
Chapter 10 Special Features: SNMP
About SNMP and the Device Server Agent......................................... 65
Network Management Components ................................................................. 65
SNMP Management Agent ............................................................................... 65
SNMP Traps ..................................................................................................... 65
MIB Support...................................................................................................... 65
Message Support ............................................................................................. 66
Supported Traps ............................................................................................... 66

Configuration Procedure: Web Interface .............................................66
Chapter 11 Configuration Management
Upgrading the Firmware ...................................................................... 67
HTTP or TFTP Upgrade Procedure.................................................................. 67

Copying the Configuration to and from a Remote Host....................... 67
When To Use Remote Configuration................................................................ 67
Download Procedure ........................................................................................ 67
TFTP Procedure ............................................................................................... 68

Resetting Configuration to Defaults..................................................... 68
Chapter 12 Reference and Certifications
Interpreting the LEDs........................................................................... 69
LEDs ................................................................................................................. 69
LED Diagnostics ............................................................................................... 69
Device EIA 232/422/485 Switch Settings ......................................................... 70
RJ-45 Pinouts ................................................................................................... 70

Safety Statements ............................................................................... 70
PortServer TS 8/16 ........................................................................................... 70
Rack Mounting Installation (PortServer TS 16 Rack and DC Rack)................. 71
PortServer TS 1/3 + Modem............................................................................. 71

Specifications ...................................................................................... 72
PortServer TS 8/16 ........................................................................................... 72
Digi One TS Wireless, PortServer TS 2/4 Wireless.......................................... 73
PortServer TS 2/4 MEI, Digi One TS ................................................................ 74
PortServer TS 2/4 ............................................................................................. 74
PortServer TS 1/3 + Modem............................................................................. 75

Contents

5

Regulatory Notices .............................................................................. 76
Certifications........................................................................................ 78
FCC Part 15 Class A (PortServer TS 8) .......................................................... 78
Radio Frequency Interference (RFI) (FCC 15.105) .......................................... 78
Labeling Requirements (FCC 15.19) ................................................................ 78
Modifications (FCC 15.21) ................................................................................ 78
Cables (FCC 15.27).......................................................................................... 78
ICES 003 Class B ( Digi One TS, Digi One TS Wireless, PortServer TS 2/4,
PortServer TS 2/4 MEI, PortServer TS 2/4 Wireless,
PortServer TS 16).............................................................. 78
Antennae (Wireless only) ................................................................................. 78
Maximum Permissible Exposure (Wireless only) ............................................. 79
Declaration of Conformity ................................................................................. 79

Digi Contact Information ...................................................................... 80

6

Contents

Introduction

Chapter 1
About This Guide
Purpose

This user guide provides the following:
• Configuration and administration procedures
• Configuration examples
Audience

This guide is intended for the person responsible for configuring and
administering device server. It assumes that this person has experience
configuring network devices and is familiar with networking concepts.
Scope

This guide provides step-by-step instructions for configuring and
administering your Digi device’s main features. It focuses on performing
these tasks through the Web user interface. It does not address how to
configure every option, provide complete information on commands, or
discuss hardware installation. These topics are covered in other
documents in the Digi library.
Other Documents in the Library
Related documents in the library include:
Quick Start Guide

The guide that comes in the package with the Digi device covering the first
steps necessary to get your device up and running.
Digi Command Reference

This online manual, available on the Software and Documentation CD,
provides complete information on commands.
RealPort Setup Guides

These online manuals provide information on setting up servers for
RealPort software.
Online Help for the Web UI

This context-sensitive online help provides information on configuration
fields used with web browser configuration interface.

Chapter 1

Introduction

7

Setup Overview
Following is an overview of the process for setting up a device in the Digi
TS family of devices for use. The rest of this guide provides details on each
step of the process.
Step A: Plan

Before beginning setup, consider the following:
• How to assign an IP address to the Digi device’s Ethernet interface,
which can be accomplished in a number of ways. See "Configuring
the IP Address" on page 13.
• How to configure serial ports. A key consideration is whether to use
RealPort. Other considerations include the type of peripheral that
will connect to the port and the peripheral’s cabling requirements.
See "Setting Up RealPort" on page 35 and the online RealPort
driver documentation and Cable Guide, both of which are on the
Software and Documentation CD.
• The various ways in which your Digi device can be configured. See
"About Configuration Methods" on page 9 for more information.
Step B: Set Up the Hardware

1. If the Digi device supports multiple serial port interfaces (EIA-232,
EIA-422/485), set the interface with the dip switches on the device.
2. Connect the device to the network.
3. Connect peripherals to serial ports. See the Cable Guide on the
Software and Documentation CD.
4. Connect the power supply to the Digi device.
Step C: Install and Setup Digi Port Authority-Remote

Digi Port Authority-Remote is a utility that provides one of the ways to
configure an IP address and also provides port monitoring.
Step D: Configure an IP Address

There are a number of ways to configure an IP address. See "Configuring
the IP Address" on page 13 for more information.
Step E: Configure Ports

See the following for more information:
• "Setting Up RealPort" on page 35
• "Network Settings" on page 17

8

Chapter 1 Introduction

Step F: Configure Other Features as Required

See the following for information on setting up other features:
• "PPP Settings" on page 31
• "Configuring Autoconnection" on page 43
• "Configuring IP Routing" on page 47
• "Configuring Security Features" on page 49
• "Special Features:Domain Name System (DNS)" on page 63
Supported Devices
This manual provides information on the following Digi devices:
• Digi One TS, Digi One TS H (high temperature), and Digi One TS
Wireless
• PortServer TS 1/3 + Modem
• PortServer TS 2/4, PortServer TS 2/4 MEI, PortServer TS 2/4 H,
PortServer TS 2/4 MEI H, and PortServer 2/4 Wireless
• PortServer TS 8/16, PortServer TS 16 Rack, PortServer TS 16 DC
Rack
About Configuration Methods
Use this section to learn about the different configuration methods.
Configure the Digi Device with the Wizard

Simply follow the prompts and choose your configuration with the wizard.
Choose either a Microsoft Windows or Unix platform.
Configure the Digi Device from an Attached Terminal

With this method, you cable a terminal or PC running terminal emulation
software to a device server port and then use the command line to enter
commands. This method allows you to configure all features. It requires,
however, that you and the device server be in the same location. Some
users find it advantageous to configure the device server IP address this
way and then use one of the other methods for the rest of the configuration.
Configure the Digi Device from a Telnet Session

With this method, you Telnet to the device server and use the command
line to complete configuration tasks. The only disadvantage to this method
is that you have to configure the device server with an IP address before
you can Telnet to it.
Configure the Digi Device from the Web Interface

The great advantage to this method is ease of use. This method requires
that you configure the IP address before you can access the configuration
from the web interface, however, some features cannot be configured this
way.

Chapter 1

Introduction

9

Downloading a Configuration File

With this method, you configure a Digi device and then do the following:
1. Download an existing configuration file to a host system.
2. Edit the file with specific configuration using a text editor.
3. Upload the file to the device server.
This an excellent method for maintaining highly similar configuration files
for multiple Digi devices. The disadvantage is that the device server
requires some configuration steps, such as the IP address, to be
completed before it can be used.
Accessing the Configuration from the Web Interface
To access the configuration from the web interface, follow these steps.
This procedure assumes that you have configured the Digi device with an
IP address already. See "Configuring the IP Address" on page 13.
1. Access the Digi device from a web browser by specifying the device
server’s IP address in the URL window.
2. Log on as root. The default password is dbps.
Quick Find Table
The following table is a quick reference for specific features and where to
find the web interface configuration procedures.
The Digi TS Family includes the following devices:
• Digi One TS (and high temperature models)
• Digi One TS Wireless
• PortServer TS 2 (and high temperature models)
• PortServer TS 4 (and high temperature models)
• PortServer TS 2 MEI (and high temperature models)
• PortServer TS 4 MEI (and high temperature models)
• PortServer TS 2 Wireless
• PortServer TS 4 Wireless
• PortServer TS 1 + Modem
• PortServer TS 3 + Modem
• PortServer TS 8
• PortServer TS 16 (and Rack models)
Feature

10

Products Availability

Configuration Details

RealPort

Digi TS Family

Serial Port > Port Profile >
RealPort

Wireless

Digi One TS Wireless
Digi One RealPort Wireless
PortServer TS 2/4 Wireless

Network > Wireless LAN
Settings

Chapter 1 Introduction

Feature

Chapter 1

Introduction

Products Availability

Configuration Details

Modem Emulation

Digi One TS
PortServer TS 2/4 MEI
PortServer TS 2/4 Wireless
PortServer TS 1 + Modem
PortServer TS 3 + Modem
PortServer TS 8/16

Serial Port > Port Profile >
Modem Emulation

Embedded Modem

PortServer TS 1 + Modem
PortServer TS 3 + Modem

Serial Port > Port Profile >
Internal Modem

AutoConnection

Digi TS Family

Serial Port > Port Profile
>TCP Sockets

IP Routing

PortServer TS 8/16

Serial Port > Port Profile > IA
> Serial Master > Packet
Routing

Access Control

Digi TS Family

User > New User >
determine access

DNS

Digi TS Family

System > System Name

Industrial
Automation (IA)

Digi One TS
PortServer TS 2/4 MEI
PortServer TS 2/4 Wireless
PortServer TS 1 + Modem
PortServer TS 3 + Modem
PortServer TS 8/16

Serial Port > Port Profile
>Industrial Automation

Power Over Serial
Port

Digi One TS Wireless
Digi One RealPort Wireless
PortServer TS 2/4 Wireless
PortServer TS 2/4 MEI

See "Special Features:
Power Over the Serial Ports"
on page 59

PPP

Digi TS Family

System > PPP

SSH Version 2

PortServer TS 2/4 MEI
PortServer TS 8/16

Network > Security >
Custom

TCP Socket
Communication

Digi TS Family

Serial Port > Port Profile
>TCP Sockets

UDP Multicast
Communication

Digi TS Family

Serial Port > Port Profile
>UDP Sockets

RADIUS

PortServer TS 8/16

Security > RADIUS

Power Management

PortServer TS 2/4 MEI
PortServer TS 2/4 Wireless
PortServer TS 8/16

Serial Port > Port Profile
>Power Management

11

12

Chapter 1 Introduction

Configuring the IP Address

Chapter 2

The next step in the device configuration process is to configure an IP
address and access the device for more advanced configurations. You
must set the initial IP before you can use the web interface. Once the IP is
set, the device can be accessed through the web interface and any
changes made including changing the IP address.
Options for Configuring the IP Address and Mask
The device server IP address can be configured using the following
methods:
• With the Wizard from the Software and Documentation CD. (Insert
the CD and the wizard automatically pops up for Microsoft Windows
systems. If you have a UNIX system see the back of the quick start
guide for mounting instructions.)
•

With Digi Port Authority-Remote, a Digi utility on the Software and
Documentation CD.
• From the command line, using the set config command. See the
Digi Command Reference for more details.
• By updating the ARP table on a server and then pinging the Digi
device (called ARP-Ping, see "Configuring the IP Address Using
ARP-Ping" on page 14).
• Using a DHCP server ("Configuring an IP Address using DHCP and
RARP" on page 15.)
• Using a RARP server ("Configuring an IP Address using DHCP and
RARP" on page 15.)
The IP address and mask can also be changed using the web interface,
but not for initial IP address configuration.
Device Support: Digi Port Authority-Remote and ARP-Ping for IP Address
Configuration

Not all Digi devices can use Digi Port Authority-Remote and ARP-Ping for
IP address configuration. To determine if you can use these features, find
the hardware label on your Digi device and then use the table below to
determine whether this feature is available:
Device

Chapter 2

Part Number

Revision Required

Digi One IA RealPort

50000764-01

F or higher

Digi One RealPort

50000723-01

J or higher

PortServer TS 2

50000723-02

J or higher

PortServer TS 4

50000723-03

G or higher

Configuring the IP Address

13

Configuring the IP Address with Digi Port Authority-Remote
Use this section to configure an initial IP address, subnet mask, and default
gateway using Digi Port Authority-Remote. This procedure cannot be used
to change the IP address, but only to assign the initial IP address. It also
cannot be used if a DHCP server is active.
Assumptions

This procedure assumes the following:
• That your Digi device supports this feature. See "Device Support:
Digi Port Authority-Remote and ARP-Ping for IP Address
Configuration" on page 13.
• That your Digi device is connected to the Ethernet network.
• That the Digi device has DHCP client turned on. This is the default
setting and it will be on unless it was turned off.
• That you do not have a DHCP server to serve IP address. If you do,
use the DHCP procedure. See "Configuring an IP Address using
DHCP and RARP" on page 15.
• That you have installed Digi Port Authority-Remote version 2.01.11
or later. Click the Help button on the tool bar in Digi Port AuthorityRemote to check the version number.
Procedure

1. Run Digi Port Authority-Remote.
2. Click Discover. A list of Digi devices appears. Systems with IP
addresses of 0.0.0.0 need IP addresses.
3. Select a device from the list and then click Configure.
4. Supply an IP address, subnet mask, and default gateway and then
choose OK.
Digi Port Authority-Remote configures the IP address, subnet mask,
and default gateway.
Configuring the IP Address Using ARP-Ping
An IP address can be configured by manually updating a server’s ARP
table and then pinging the Digi device.
Note:

The ARP-Ping command assigns the IP address you designate but also
assigns default subnet mask and gateway addresses. It is necessary to
change the subnet mask and gateway addresses.

Assumptions

This procedure assumes the following:
• That your Digi device supports this feature. See "Device Support:
Digi Port Authority-Remote and ARP-Ping for IP Address
Configuration" on page 13.
• That your Digi device is connected to the Ethernet network

14

Chapter 2 Configuring the IP Address

Procedure

1. Record the MAC address of the Digi device. The MAC address is on the
back of the unit.
2. Access a server on the same subnet as the Digi device.
3. Manually update the server’s ARP table using the Digi device’s MAC
address and the IP address you want assigned to the Digi device. The
following is an example of how this is done on a Windows NT 4.0
system:
arp -s 143.191.2.1 00-00-9d-22-23-60

4. Ping the Digi device using the IP address just assigned. The following is
an example:
ping 143.191.2.1

The ping will probably time out before there is a response from the Digi
device.
5. Wait several seconds and then ping the Digi device again.
The Digi device replies to the ping, indicating that the IP address has
been configured.
Configuring an IP Address using DHCP and RARP
About DHCP and RARP

When the device server boots, it transmits a DHCP request and a RARP
request. This continues until an address is assigned.
Procedure

To use RARP or DHCP follow these steps:
1. Set up an entry for an address on a DHCP or RARP server. If you
intend to use RealPort, do the following:
• Reserve a permanent IP address.
•

Record the IP address. You will need it when you configure the
RealPort driver.
2. Power on the device server.
The DHCP or RARP server assigns the device server an IP address.
Accessing the Digi Device
1. Enter the IP address in the URL bar of your browser.
2. Enter your login name (root) and password (dbps).
Note:

Chapter 2

The following screen appears allowing you to configure the device for your
specific needs. A tutorial is available to guide you in your decisions. The Help

Configuring the IP Address

15

button in the upper right corner is also available.

From the web interface, you make any changes you need for your
configuration. Remember to click Apply to save your changes and Reboot
when you are ready for the changes to take effect.

16

Chapter 2 Configuring the IP Address

Configuration

Chapter 3

The next step in the device setup process is to configure the network and
serial port settings. In order to access the web interface an IP address
must be assigned. It is assumed you have logged onto the web interface
using the username, root and password, dbps in order to make any
changes or additional configuration assignments. However, it is important
to note that if you have used the wizard, your configuration is complete and
you do not additional changes.
Network Settings
1. Click Network to view the IP settings or make any changes to the IP
address.

2. Click Advance Network Settings.

Chapter 3

Configuration

17

Adjust the network settings to fit your configuration needs. If you need
additional information use the Help button on the top right hand corner of
the configuration screen.
3. Click Apply to save any changes you make.
4. Click Reboot for changes to take effect.
Procedure for Using a Name Server

To configure a DNS server, follow these steps:
1. Click Network and select Use the following IP address.
2. Enter the IP address for the DNS server in the Name Server box. The
DNS server maps names (MyDeviceName.mycompany.com) to IP
addresses (192.105.1.2).
3. Enter a name for a group of network devices.
4. Enter the domain name that this device will live in and is tied to the DNS
server address assigned in step 2. This name can be used by other
network devices to talk to it, instead of using the its IP address. Get this
name from the network administrator, because it must be entered in the
DNS server to work properly.
5. Enter the Base Socket. The base socket is the incoming port number
which remote devices need to use to access the device using the
named protocols.
Note:

18

Base Socket
This determines which network port (socket) on this Digi terminal server
another network device (such as another Digi terminal server or a PC) uses to
communicate using certain services. Most applications can leave this value
unchanged. To calculate these settings:
Telnet port = Base Socket + Serial Port Number
Raw port = Base Socket + 100 + Serial Port Number
Chapter 3 Configuration

Service
telnet
raw (TCP or UDP)

Base Socket
2000
2000

Network Port
2001
2101

6. Click Apply.
7. Click Reboot for changes to take effect.
Configuring the Serial Ports
1. Click Serial Ports under Configuration.

2. Click the port number that you want to configure.
3. Click Change Profile and select a profile based on the device you have
connected to your port.
Note:

Chapter 3

Configuration

The following section shows the settings available for each profile.

19

Note:

The ‘More’ link will describe the profiles with additional information.

Note:

Profiles appear depending on your device. Naturally, if you do not have a
device capable of a specific profile such as Power Management or Wireless,
you will not have that particular profile available.

4. Click Apply to save the profile. The interface will determine any
additional settings and advise you what tab to click next. See "Port
Profiles" on page 21 or click Help for additional information.
5. A port profile or port options page will come up and ask for additional
parameters if needed. Enter the appropriate parameters and click Apply.
6. Click Reboot for changes to take effect.

20

Chapter 3 Configuration

Port Profiles
Each port profile determines the settings needed. The following
screenshots of each profile show the port settings. For a complete
description of each profile click the Help button.
RealPort

Installed on a network-based PC, RealPort emulates a serial port. That is,
the application “thinks” it is working with a real serial port, such as COM1.
When the application sends data to this serial port, RealPort ships the data
across the network to the device server which in turn routes it to the serial
device. This is also referred to as COM Port Redirection. The network is
transparent to both the application and the device.

Console Management

Access a device's console port over a network connection. Most network
devices such as routers, switches, and servers offer serial port(s) for
management. Instead of connecting a terminal to the console port, cable
the console port to the serial port of your Digi device. Then using TCP/IP
utilities like reverse telnet, network administrators can access these
consoled serial ports from the LAN.

Chapter 3

Configuration

21

TCP Sockets

TCP socket communication enables serial devices to communicate with
each other over an Ethernet network as though they were connected by a
serial cable.
Configuring TCP socket communications involves configuring the Digi
device for the following types of connections:
• Inbound connections, that is, connections that are initiated by the
device on the other side of the network.
• Outbound connection, that is, connections that are initiated by the
device connected to the serial port.

Note:

TCP Sockets profile is also the profile to use for Autoconnection. See "Click
Reboot for changes to take effect." on page 33 for more information.

UDP Sockets

The Digi TS Family devices are capable of UDP multicast. UDP multicast is
used to send serial data over an Ethernet cable to one or many hosts at the
same time. UDP is a ‘connectionless’ protocol, meaning UDP does not
need a protocol, but is sending data without any form of acknowledgement
or error correction. Up to 64 devices can receive a UDP multicast at one
time. Both the transmitting and receiving devices must be configured
properly for UDP multicast to work.
Configuring UDP multicast communications involves configuring the Digi
device for the following types of connections:
• Inbound connections, that is, connections that are initiated by the
device on the other side of the network.
• Outbound connection, that is, connections that are initiated by the
device connected to the serial port.

22

Chapter 3 Configuration

Note:

The serial parameters for two connecting devices must match meaning if one
device is set for 9600 bps, the other device must be set for the same rate.

Serial Bridging

A serial bridge is a network connection between two serial devices, each of
which uses a device server. The serial devices “think” they are
communicating with each other across a serial cable using serial
communication techniques. There is no need to reconfigure the server or
the serial device. Neither is aware of the intervening network.
This profile configures each side of the bridge separately. Repeat the
configuration for the second Digi device server of the bridge specifying the
IP address of the first Digi device server.

Chapter 3

Configuration

23

Printer

This profile allows you to connect a printer to a serial port. Use this profile if
you intend to print using the lpd protocol on your UNIX system.

Note:

Refer to your UNIX User Guide for tips on configuring the print spooler on
your UNIX system.

Terminal

This profile allows you to connect to a terminal to the serial port.

24

Chapter 3 Configuration

Industrial Automation

The Industrial Automation (IA) Profile allows you to connect IA devices and
PLCs to the serial port in order to network-enable the devices. Use this
profile if you need to communicate over the network with an IA device or
PLC that only uses serial protocols. This profile may also be used to add
routing capabilities to IA devices or PLCs that act as serial masters and
send packets to various systems or devices on the network. Industrial
Automation enhances the IA device or PLC connected to the serial port.

Modem Profiles

There are 3 types of modem profiles:
• Modem Emulation
Modem Emulation allows the Digi device to function as a modem. A
short description follow the modem profiles listed below. For more
specific information about Modem Emulation see "Special Features:
Modem Emulation" on page 43, including AT commands specific to
this function.
• Modem
The Modem profile configures the Digi device for attaching a modem
to a serial port. For more specific information about the modem
profile use the Help button in the upper right corner on the profile
page of the web interface.
• Internal Modem
The Internal Modem profile (not listed in the graphic) is specific to
the PortServer TS 1/3+Modem devices. The fully functioning

Chapter 3

Configuration

25

modem is embedded in port one and uses the standard AT
command set. See the Documentation on the Digi CD for the
complete AT Command Reference.
Modem Emulation

Modem Emulation allows you to configure the serial port to act as a
modem. The Digi device emulates modem responses to a serial device
and seamlessly sends and receives data over an Ethernet network instead
of a PSTN (Public Switched Telephone Network). The advantage for a user
is the ability to retain legacy software applications without modification and
use a less expensive Ethernet network in place of public telephone lines.

Modem

Modem allows you to attach modem devices to the serial port in order to
establish or receive connections from other systems and modems.

Note:

26

Click the PPP Configuration link to set up incoming, outgoing or advanced
PPP settings if the attached modem uses PPP connections. See "System
Configuration" on page 31 for more information about PPP settings.

Chapter 3 Configuration

Power Management

The Power Controller feature allows the administrators of the Digi CM to
use console management to control power functions. Power control
consists of three basic functions: on, off, and reboot (power cycle).There
are two typical scenarios when using a power controller. The simplest
scenario is a non-serial device connected to a power controller (for
example, an environmental sensor controller or a tape backup device).

Note:

Chapter 3

Configuration

Power controller settings can be automatically detected or configured
manually.

27

Custom

This profile allows you to see all settings and set them accordingly. Use this
profile only if your application does not fit into any of the predefined port
profiles.

28

Chapter 3 Configuration

User Configuration
Although it is not required, the device server is often configured to
accommodate the requirements of particular users. Typical configurable
user attributes include:
• Whether the user is required to supply a password.
• Autoconnection attributes, such as the system to which the user
should be automatically connected at login.
• The interface the device presents the user, such as a menu or
command line.
• Whether the user has access to outbound ports.
Note:

For information on configuring PPP users, see "PPP Settings" on page 31.

Common User Features

Feature

Description

autoconnect

Automatically connects the user to the host specified on the autohost
field using the service (TCP port) defined on the autoport or
autoservice fields.
Autoconnection can also be implemented by port instead of by user.

Default
access type

Defines the type of access the user is restricted to. Menu, command
line, autoconnect, and outgoing and netservice are the types.

Menu
access

Defines the menu that is to be presented to a user with menu
access.

Port access

Defines the number of outbound ports a user connected over the
LAN can access at one time.
This feature is not configurable from the web interface.

PPP

Defines PPP-related parameters for the user.

Routing
updates

Defines whether RIP routing updates are forwarded over the link to
this user.

1. Click Users > New User
2. Enter the Username, password, and password confirmation and click
Next.

3. Select the profile that fits the user’s environment/needs and click Next.

Chapter 3

Configuration

29

4. Select the Ports to manage or the Autoconnect function if needed and
click Next.
5. Review settings and click Finish.
The Advanced tab under User allows you to set Escape characters for
Connect, Telnet, Rlogin, and Kill as well as an SSH Public Key. Click Apply
to save the settings.
6. Click Reboot for changes to take effect.
Security Configuration
Security settings allow the administrator to set passwords, security levels,
and authentication via RADIUS server.Some services, such as Telnet and
Rlogin, can be disabled for inbound users. This means that the users
cannot access the Digi device using those services. This feature allows
you to turn off individual services or to specify a security level, which
means that all services not included in that level are turned off. The
following services can be turned off.
• HTTP
• RealPort
• Reverse TCP
• Reverse Telnet
• Remote login
• Remote shell
• SNMP
•
•

SSH
Telnet

Procedure

1. Click Security > and enter a new password for the root administrator.
2. Enter the confirmation password and click Apply.
3. Click Network Security and select the security level appropriate to your
environment and click Apply.
Note:

30

Secure Access Levels Secure: SSH is the only service available to inbound users.
High: SSH, HTTP, SNMP, and RealPort services are available to inbound

Chapter 3 Configuration

users.
Normal: all services are available.
Custom, which means you can select services to turn off.
The default service level is Normal.

4. Click RADIUS and select Authenticate users via RADIUS server.
5. Enter the appropriate IP address and secret and click Apply. The secret
is the password used for encryption of messages between the RADIUS
server and the Digi device.
6. Click Reboot for changes to take effect.
System Configuration
System settings allow you to set the bandwidth (throughput or latency) the
date and time, PPP connections, and SNMP traps.
1. Click System and enter the System Description (network name
assigned to the Digi device), Contact (SNMP contact person -often the
network administrator), Location (text description of the physical
location of the Digi device), and Optimization (bandwidth used on the
network) and click Apply
Note:

Latency - Allows fast access to time-sensitive devices. Requires more
network bandwidth.
Throughput - Allows better network performance at higher throughput.

2. Click Date/Time
3. Enter the date and time information and click Apply.
4. Click Reboot for changes to take effect.
PPP Settings

Under System Configuration, users can set the PPP (Point-to-Point
Protocol) options to enable or disable the dynamic IP address pool. The
dynamic IP address pool is a set of reserved IP addresses unique to the
network that are assigned to the incoming connections. Users set the first
IP address to use and the number of sequential addresses (plus one) to be
reserved for assignment.
1. Click PPP.
2. If you are using PPP select Enable Dynamic IP Address Pool for
Incoming Connections.
3. Enter the first reserved IP address of the incoming connections and the
number of addresses to use and click Apply.
4. Click Incoming Connections > New Connection

Chapter 3

Configuration

31

5. Enter the appropriate parameters and click Apply.
6. Click Reboot for changes to take effect.
For outgoing connections, CHAP or PAP authentication, password
configuration, follow the procedure for Outgoing Connections.
1. Click Outgoing Connections

Note:

CHAP authentication can be used to restrict PPP user access to outbound
ports.

2. Enter the appropriate parameters and click Apply.
3. Click Reboot for changes to take effect.
For dynamic routing or proxy ARP settings follow the procedure for
Advanced PPP settings.
4. Click Advanced PPP settings.

32

Chapter 3 Configuration

5.
6.
7.
8.
9.

Select Enable Dynamic Routing (RIPv1)
Select the passive or active route setting.
Select the Process ARP requests if appropriate.
Click Apply.
Click Reboot for changes to take effect.

About Autoconnection
The autoconnection feature allows you to configure a user to access the
device server and then be automatically connected to a host on the LAN.
You can implement autoconnection in the following ways:
• By port, where all port users are automatically connected to the
same host. The device server is completely transparent to them.
•

By user, where a user is required to log on and may be required to
supply a password. Once the user is authenticated, an automatic
connection to a host is made.

Configuring a Port for Autoconnection
1. Select Serial Ports under Configuration.
2. Click the TCP Sockets Port Profile.
Note:

TCP Sockets is the Autoconnection profile.

3. Click Apply.
4. Select Automatically establish TCP connections and the appropriate
parameters. Use the Help button for addtional information.
5. Click Apply.
6. Click Reboot for changes to take effect.
Note:

Chapter 3

Configuration

To return to the main Ports menu, choose Ports from the Menu again.

33

Configuring a User for Autoconnection
1. Click Users from the menu.
2. Choose New User.
3. Enter a username and then click Next.
4. Select the “Terminal/Terminal Emulation” user profile and click Next
5. Select Automatically connect to a ...
Be sure to specify the following:
• Hostname or IP address that will be the destination
• Service
• Destination TCP port number, which determines the type of
connection for this user (such as 23 for Telnet)
6. Click Next and Verify the settings.
7. Click Finish to save settings.

34

Chapter 3 Configuration

Setting Up RealPort

Chapter 4

The next step in the device setup process is to configure RealPort. This
section provides a brief introduction to RealPort. If you use the wizard,
follow the steps in the pop-up after selecting the Incoming scenario.
About RealPort
What is RealPort?

RealPort is a feature that allows network-based host systems to use the
ports of the device server as though they were the host system’s own ports,
appearing and behaving as local ports to the network-based host.
RealPort Advantages

RealPort provides the following advantages:
• It expands the number of ports available to the host system.
•

•

•

It enables device server ports to be treated as if they were directly
connected to the host, which means they use all standard operating
system interfaces that control baud rate, parity, stop bits, and flow
control.
It enables host administrators to do most of the required
configuration on the host, the system with which the administrator is
most familiar.
It dramatically reduces host CPU overhead because multiple
terminal or printer sessions are multiplexed over the same TCP/IP
connection.

Configuring the RealPort Software

You must install and configure RealPort software on each host that will use
RealPort ports. See the RealPort documentation for more information.
1. From the CD, click Software. (If the wizard pops up, click cancel.)

Chapter 4

Setting Up RealPort

35

2. From the Control Panel, click Add new hardware and follow the prompts
listed above.
The files are located in the drivers\windows\win2k\realport folder.
If you use the wizard, follow the steps in the pop-up after selecting the
Incoming scenario.

36

Chapter 4 Setting Up RealPort

Special Features: Wireless

Chapter 5

Use this chapter for the initial configuration of your Digi Wireless device.
After the initial configuration, the device can be configured using the same
methods as the other Digi TS family products.
Configuration Considerations
The Digi wireless devices work ONLY with the antennae provided. You can
use the wizard to configure your wireless device available on the Software
and Documentation CD. You will need an Ethernet cable and a network PC
to configure the wireless Digi device. After assigning the IP address,
access the device from your browser by entering the IP address in the URL
address bar.

Using Ethernet

1. Connect serial cable, Ethernet cable, and power supply.

2. Insert the CD in the drive. The configuration wizard will automatically
start. Follow the steps in the wizard (either for Microsoft Windows or
Unix) to configure the device.
Or:
If you do not want to use the wizard, click Cancel and follow the
remaining procedure steps to set up the IP address and configure the
device through the web interface.
3. Select Discover Digi Device (from the CD).
4. Select the wireless device and assign the IP address.
5. Click Set IP.
6. Enter the IP address, Subnet, and Gateway mask and click OK.
Chapter 5

Special Features: Wireless

37

7. Select the device and click Configure to launch your browser.
8. Enter the username root and password dbps and click OK.

The home screen appears.

9. Click Network > Wireless LAN

38

Chapter 5 Special Features: Wireless

10. .Enter parameters, click Apply to save.

11. Click Reboot for changes to take effect.
12. Click Advanced Network Settings, enter any additional parameters needed
and click Apply to save..

13. Unplug the Ethernet cable from the Digi device, disconnect the power,
and power the unit up (reboot).
Configuration is complete.
Chapter 5

Special Features: Wireless

39

40

Chapter 5 Special Features: Wireless

Special Features: Embedded Modem

Chapter 6
Embedded Modem

The PortServer TS 1+ Modem and PortServer TS 3 + Modem functions as
both terminal server and modem. The embedded modem can be used with
PPP, dial-out, or auto answer and conforms to the standard AT command
interface.
The PortServer TS 1 + Modem and PortServer TS 3 + Modem allow
• remote monitoring
• diagnostics
• data collection
• dial-up, wireless, or Ethernet connectivity
For a complete AT command reference see the AT Command reference
from the CD under Documentation.
The remaining ports can be configured the same as any Digi TS Family
product, either through the web interface or command line.
Installing the PortServer TS 1/3 + Modem

The PortServer TS 1/3 + Modem comes with a bi-directional cable for
connecting the modem (port 1) to the phone line.
1. Plug the cable with the ferrite end into the modem port.
2. Plug other end into phone line.
3. Connect Ethernet.
4. Connect power supply.

Configuring the PortServer TS 1/3 + Modem

1. Follow the setup wizard from the CD to assign an IP.
2. If the wizard scenarios need additional configuration, login to the device
IP from the URL.
3. Select Serial Ports > Change profile
4. Select the appropriate profile (Custom shows all options)

Chapter 6

Special Features: Embedded Modem

41

5. Enter the appropriate parameters and click Apply to save.
6. Click Reboot for changes to apply.

42

Chapter 6 Special Features: Embedded Modem

Special Features: Modem Emulation

Chapter 7
Modem Emulation

The following Digi TS Family products include Modem emulation:
• Digi One TS
• Digi One TS Wireless
• PortServer TS 2/4 MEI
• PortServer TS 2/4 Wireless
• PortServer TS 1/3 + Modem
Note:

Port one on the PortServer TS 1/3 + Modem is an actual embedded modem.
The remaining ports are capable of emulating a modem.

• PortServer 8/16
Modem emulation enables a system administrator to configure a
networked Digi device to act as a modem. The Digi device emulates
modem responses to a serial device and seamlessly sends and receives
data over an Ethernet network instead of a PSTN (Public Switched
Telephone Network). The advantage for a user is the ability to retain legacy
software applications without modification and use a less expensive
Ethernet network in place of public telephone lines.
To use a Digi device for modem emulation, do the following:
• Use a cable with the correct wiring pinouts (see "Modem Emulation
Cable Signals" on page 44)
• Configure the serial ports and device type with the Web Interface
serial port profile - Modem Emulation
Note:

Before AT commands are accepted, DSR must go high on the Digi deviceCommon User Scenarios

The Digi device in modem emulation mode allows for the easy replacement
of modems in almost any environment where there is a LAN or WAN.

In Diagram A, the Digi One TS replaces a modem connected to a
workstation running an application. The Digi One TS allows for the use of
software applications without modification by responding to all the AT
commands configured in the workstation application. The Digi One TS
Chapter 7

Special Features: Modem Emulation

43

connects to the IP Address of the server when an
ATDT ipaddress:port (ATDT 192.168.25.5:50001)
command is issued. Once the remote device establishes the TCP
connection, a CONNECT message is sent to the serial port and only then
does the Digi device switch from AT command mode to data mode. Using
the modem escape sequence or dropping DTR on either side terminates
the connection. A DISCONNECT message will be sent to the application if
the remote side closes the TCP connection.

User Scenario-Diagram B
Workstation

Serial cable

O NE

TS

#1
Digi One TS
D IGI

Ethernet

Workstation
#2
Digi One TS
192.168.25.30
D IGI

O NE

TS

Serial cable

In Diagram B, two Digi devices will replace modems on both sides of the
connection. The initiation of the connection occurs with either of the Digi
devices. If both ends are Digi devices, the TCP listening port number is
50001 for port 1. An example of the connection command is ATDT
192.168.25.30:50001. Upon establishing a successful TCP
connection, a CONNECT message is sent to the serial port and only then
does the Digi device server switch from AT command mode to data mode.
After the CONNECT is received, the transmission of data begins. Using
the modem escape sequence or dropping DTR on either side terminates
the connection.
Modem emulation has the ability to communicate to an infinite number of
other devices.
Modem Emulation Cable Signals
Use the following signal assignments to make a cable connecting the Digi
device to a serial device.
Serial Device

Digi Device

CTS (in)

RTS (out)

RTS (out)

CTS (in)

DSR (in)

DSR (in)

DTR (out)

44

Chapter 7 Special Features: Modem Emulation

Serial Device

Digi Device

DCD (in)

DTR (out)

TX (out)

RX (in)

RX (in)

TX (out)

GND

GND

DSR and DTR on the serial device side are connected to the DSR signal of
the Digi device.
Scenarios for Modem Emulation
Outgoing Modem Emulation Connection

Serial device sends ATDx.x.x.x:y command, which triggers the device
server to establish a telnet connection to destination IP=x.x.x.x, port=y.
Incoming Modem Emulation Connection

A device on the network telnets to port 50001 (50000+1 = 1st serial port).
This incoming connection triggers the device server to generate a RING on
the serial port. The device attached to the serial port will answer the RING
and the connection is established.
Modem Emulation Pooling

This is a combination of Incoming Modem Emulation Connection and a
hunt group. A device on the network telnets to port 50000. The device
server checks if a serial port configured for modem emulation is available.
If so, it connects to the port, otherwise returns an error.
Modem Emulation Bridge

A combination of Outgoing and Incoming Modem Emulation Connections,
in which both serial devices require to talk to a modem. The first serial
device telnets to the second device using ATDx.x.x.x:y, the second device
gets a RING and accepts the incoming telnet connection.
Originating, Answering, and Disconnecting Calls
In the following table, an application requests a TCP session with the Digi
device. The table displays the responses of the Digi device and application
as they negotiate a TCP connection.
Application AT Command
AT&F
ATDT ipaddress:TCPport#

+++

Chapter 7 Digi Device Server Response Notes OK. AT command request to restore defaults to factory settings-Digi device server responds OK. Receives request to start a TCP session. CONNECT 115200. Request to start TCP session with IP address and TCP port number of the Digi device server-Digi device server starts a TCP session OK Escape sequence is sent

is Pause in seconds with “+++” being the escape sequence in ASCII characters Digi device server switches from AT command to data mode Special Features: Modem Emulation 45 Application AT Command ATH Digi Device Server Response NO CARRIER response sent Notes Disconnect AT command is sent-Digi device server responds with NO CARRIER In the following table, the Digi device server receives a request for a connection. AT Command ATA (or ATS0=n) Digi Device Server Response Notes RING The Digi device server sends a Call Notification CONNECT 115200 Manual (ATA) or Auto Answer (ATS0=n) response-the Digi device server sends a CONNECT message when the TCP session is started NO CARRIER The Digi device server sends a NO CARRIER message when the remote disconnects Originating Calls To send data to a Digi device server, enter the following information for your application replacing the telephone number with the Digi device server’s IP address and TCP port number. Enter the following command: ATDT ipaddress:tcp_port# an example is ATDT 146.135.13.5:50001 Answering Calls The Digi device server listens on a pre-defined TCP port to receive data. When the Digi device server receives a call notification (RING) through a serial port to begin a TCP connection, it needs to reply with an ATA or a pre-configured Auto-Answer to answer the call. Note: The TCP ports assigned to the serial ports are as follows: Serial port 1 listens on TCP port 50001 Serial port 2 listens on TCP port 50002 Serial port 3 listens on TCP port 50003 Serial port 4 listens on TCP port 50004 Disconnecting Calls The TCP connection disconnects by either dropping the DTR signal on the serial port or sending the escape sequence

+++

to the Digi device server.

represents a one second pause. Disconnecting Calls-Digi Device Server The Digi device sends a NO CARRIER response to the serial port when the network connection is dropped. Modem Emulation AT Command Set AT Command ATA 46 Result Code Function Answer command: The Digi Device Server will go off hook and answer a TCP connection request. Chapter 7 Special Features: Modem Emulation AT Command Function Result Code This command directs the Digi Device Server to go on-line, dial according to the IP address entered as follow 191.1.2.3:12 and attempt to establish a TCP connection. If no dial string is supplied, the Digi Device Server will respond no dial tone. Note: If the ATD command is issued before the S1 register has cleared, the modem will respond with the NO CARRIER result code. Dial Modifiers. The valid dial string parameters are described below. Punctuation characters may be used for clarity with parentheses, hyphen, and spaces being ignored. ATD: ATEn Command echo. The Digi Device Server enables or disables the echo of characters to the DTE according to the parameter supplied. The parameter value, if valid, is written to S14 bit 1. E0 : Disables command echo E1 : Enables command echo OK n=0 or 1 ERROR Otherwise ATH Disconnect (Hang up) command This command initiates a hang up sequence. H0 : Disconnect the TCP session if the modem is currently on line. H1 : If on-hook, the Digi Device Server will go off-hook and enter command mode. OK n=0 or 1 ERROR Otherwise ATIn Identification command I0 reports product code. Example: Digi Device server I1 reports 255 I2 reports “OK” I3 reports “OK” I4 reports DIGI DS_TS I5 reports “OK” I6 reports “OK” I7 reports “OK” I8 reports “ERROR” I9 reports “ERROR” Chapter 7 Special Features: Modem Emulation OK n=0 or 9 ERROR Otherwise 47 AT 48 Result Code Function Command ATLn Accepted but ignored. OK n=0 or 3 ERROR Otherwise ATMn Accepted but ignored. OK n=0 or 3 ERROR Otherwise ATNn Accepted but ignored. OK n=0 or 1 ERROR Otherwise ATOn Return to On-Line Data Mode. This command determines how the modem will enter the on-line data mode. If the modem is in the on-line command mode, the modem enters the online data mode. If the modem is in the off-line command mode (no connection), ERROR is reported. O0Enters on-line data mode. Handling is determined by the Call Establishment task. Generally, if a connection exists, this command connects the DTE back to the remote modem after an escape (+++). O1Same as above OKn = 0 or 1 and a connection exists. ERROR Otherwise or if not connected. ATP Accepted but ignored. OK ATQn Quiet Results Codes Control command. The command enables or disables the sending of the result codes to the DTE according to the parameter supplied. The parameter value, if valid, is written to S14 bit 2. Q0 Enables result code to the DTE (Default). Q1 Disables result code to the DTE OK n=0 or 1 ERROR Otherwise ATSn Read/Write S- Register. n Establishes S-register n as the last register accessed n=v Sets S-Register n to the value v. n? Reports the value of S-Register n. ATT Accepted but ignored.. OK ATVn Result Code Form. This command selects the sending of short-form or longform codes to the DTE. The parameter, if valid, is written to S14 bit 3. V0 Enables short-form (terse) result codes. Line feed is not issues before a short-form result. V1 Enables long-form (verbose) results codes (Default). OK n=0 or 1 ERROR Otherwise ATWn Accepted but ignored. OK n=0 to 3 ERROR Otherwise ATXn Accepted but ignored. OK n=0 to 3 ERROR Otherwise ATYn Accepted but ignored. OK n=0 or 1 ERROR Otherwise ATZn Accepted but ignored. (Soft Reset and restore Profile). OK n=0 or 1 ERROR Otherwise AT&Cn DCD Option. The Digi Device Server controls the DCD output in accordance with the parameter supplied. The parameter value, if valid is written to S21 bit 5. &C0 DCD remains ON at all times. &C1 DCD follows the state of the connection OK n=0 or 1 ERROR Otherwise Chapter 7 Special Features: Modem Emulation AT Function Command Result Code AT&Dn DTR Option. This command interprets the ON to OFF transition of the DTR signal from the DTE in accordance with the parameter supplied. The parameter value, if valid, is written to S21 bits 3 and 4. Also see S25. &D0 -DTR is ignored (assumed ON). Allows operation with DTEs which do not provide DSR. &D1DTR drop is interpreted by the modem as if the asynchronous escape sequence had been entered. The modem returns to asynchronous command state without disconnecting. &D2DTR drop causes the modem to hang up. Auto-answer is inhibited. (Default.) &D3DTR drop causes the modem to perform a soft reset as if the Z command were received. The &Y setting determines which profile is loaded. OK n=0 to 3 ERROR Otherwise AT&Fn Restore Factory Configuration (Profile) The Device Server loads the factory default configuration (profile). The factory defaults are identified for each command and in the S-Register descriptions. A configuration (profile) consists of a subset of S-Registers. &F0Restore factory configuration 0. &F1Restore factory configuration 1. OK n=0 or 1 ERROR Otherwise AT&Jn Accepted but ignored. OK n=0 or 1 ERROR Otherwise AT&Gn Accepted but ignored. OK n=0 or 1 ERROR Otherwise AT&Jn Accepted but ignored. OK n=0 or 1 ERROR Otherwise AT&Kn Flow control. This command defines the DTE/DCE flow control mechanism. The parameter value, if valid, is written to S39 bits 0, 1, and 2. &K0 Disables flow control &K3 Enables RTS/CTS flow control (Default) &K4 Enables XON/XOFF flow control &K5 Enables transparent XON/XOFF flow control &K6 Enables both RTS/CTS and XON/XOFF flow control. OK n=0,3,4,5,or 6 ERROR Otherwise AT&Ln Accepted but ignored. OK n=0, 1, 2 ERROR Otherwise AT&Mn Accepted but ignored. OK n=0, 1, 2 ERROR Otherwise AT&Pn Accepted but ignored. OK n=0, 1, 2 ERROR Otherwise AT&Qn Accepted but ignored. OK n=0 to 8 ERROR Otherwise Chapter 7 Special Features: Modem Emulation 49 AT 50 Result Code Function Command AT&Rn RTS/CTS Option This selects how the Digi Device Server controls CTS. CTS is modified if hardware flow control is selected (see &K command). The parameter value, if valid, is written to S21 bit2. &R0CTS reflects the ability of the modem to transmit data. For example, CTS will drop during retrains. In sync mode, CTS tracks the state of RTS; the RTS-to-CTS delay is defined by S26. In async mode, CTS is normally ON and will turn OFF only if required by flow control. &R1CTS forced on (default). In sync mode, CTS is always ON (RTS transitions are ignored). tracks the state of RTS. In async mode, CTS is normally ON and will turn OFF only if required by flow control. &R2CTS follows RTS. OK n=0 or 1 ERROR Otherwise AT&Sn DSR Override This command selects how the modem will control DSR. The parameter value, if valid, is written to S21 bit 6. &S0DSR will remain ON at all times. (Default.) &S1DSR will become active after answer tone has been detected and inactive after the carrier has been lost. OK n=0 or 1 ERROR Otherwise AT&Tn Accepted but ignored. OK n= 0 ERROR Otherwise AT&V Display Current Configuration and Stored Profiles There is no NVRAM support currently. OK AT&Vn Accepted but ignored. OK n=0 to 5 ERROR Otherwise AT&V6 Display current IP settings of the Device Server OK AT&Wn Accepted but ignored. OK n=0 or 1 ERROR Otherwise AT&Xn Accepted but ignored. OK n=0 or 1 ERROR Otherwise AT&Yn Accepted but ignored. OK n=0 or 1 ERROR Otherwise AT&Zn &Zn=x - Store Telephone Number. Currently not supported OK n=0 or 3 ERROR Otherwise AT\An Accepted but ignored. OK n=0 to 3 ERROR Otherwise AT\Gn Accepted but ignored. OK n=0 or 1 ERROR Otherwise AT\Kn Accepted but ignored. OK n=0 to 5 ERROR Otherwise Chapter 7 Special Features: Modem Emulation AT Result Code Function Command AT\Nn Operating Mode This command controls the preferred error correcting mode to be negotiated in a subsequent data connection. \N0 Selects normal speed buffered mode \N1 Serial interface selected - Selects direct mode \N2 Accepted but ignored. \N3 Accepted but ignored. \N4 Accepted but ignored. \N5 Accepted but ignored. OK n=0 to 5 ERROR Otherwise AT\Vn Accepted but ignored. OK n=0 or 1 ERROR Otherwise AT+MS Accepted but ignored. OK AT+MI Accepted but ignored. OK AT%Cn Accepted but ignored. OK n=0 to 3 ERROR Otherwise Chapter 7 Special Features: Modem Emulation 51 S-Registers Register Function 52 Range Units Saved S0 Rings to Auto-Answer Sets the number of rings required before the Digi Device Server automatically answers a call. Setting this register to Zero disables autoanswer mode. 0-255 Rings S1 Ring Counter S1 is incremented each time the modem detects a ring signal on the telephone line. S1 is cleared if no rings occur over an eight second interval. 0-255 Rings S2 Escape Character S2 holds the decimal value of the ASCII character used as the escape character. The default value corresponds to an ASCII ’+’. A value over 127 disables the escape process, i.e., no escape character will be recognized. 0-255 ASCII S3 Carriage Return Character Sets the command line and result code terminator character. Pertains to asynchronous operation only. 0-127 ASCII 13 S4 Line Feed Character Sets the character recognized as a line feed. Pertains to asynchronous operation only. The Line Feed control character is output after the Carriage Return control character if verbose result codes are used. 0-127 ASCII 10 S5 Backspace Character Sets the character recognized as a backspace. Pertains to asynchronous operation only. The modem will not recognize the Backspace character if it is set to a value that is greater than 32 ASCII. This character can be used to edit a command line. When the echo command is enabled, the modem echoes back to the local DTE the Backspace character, an ASCII space character and a second Backspace character; this means a total of three characters are transmitted each time the modem processes the Backspace character. 0-32 ASCII 8 * Default 0 0 * 43 S6 Accepted but ignored. 2-255 s * 2 S7 Accepted but ignored. 1-255 s * 50 S8 Accepted but ignored. 0-255 s * 2 S9 Accepted but ignored. 1-255 0.1 s * 6 S10 Accepted but ignored. 1-255 0.1 s * 14 S11 Accepted but ignored. 50-255 0.001 s * 95 S12 Escape Prompt Delay Defines the maximum period, in fiftieths of a second, allowed between receipt of the last character of the three escape character sequence from the DTE and sending of the OK result code to the DTE. If any characters are detected during this time, the OK will not be sent. Note that sending of the OK result code does not affect entry into command mode. 0-255 0.02 s * 50 Chapter 7 Special Features: Modem Emulation Register Function S13 Reserved S14 General Bit Mapped Options Status Indicates the status of command options. Default:138 (8Ah) (10001010b) Bit 0This bit is ignored. Bit 1Command echo (En) 0 =Disabled (E0) 1 =Enabled (E1) (Default.) Bit 2Quiet mode (Qn) 0 =Send result codes (Q0) (Default.) 1 =Do not send result codes (Q1) Bit 3Result codes (Vn) 0 =Numeric (V0) 1 =Verbose (V1) (Default.) Bit 4Reserved Bit 5Tone (T)/Pulse (P) 0 =Tone (T) (Default.) 1 =Pulse (P) Bit 6Reserved Bit 7Originate/Answer 0 =Answer 1 =Originate (Default.) Range Units - - Saved Default - * 138 (8Ah) S15 Reserved - - - S16 Accepted but ignored. - - 0 S17 Reserved - S18 Accepted but ignored. 0-255 s S19 Accepted but ignored. - - S20 Accepted but ignored. 0-255 - Chapter 7 Special Features: Modem Emulation - - * 0 0 * 0 53 Register 54 Function Range Units Saved Default S21 General Bit Mapped Options Status Indicates the status of command options. Default:52 (34h) (00110100b) Bit 0Set by &Jn command but ignored otherwise. 0 =&J0 (Default.) 1 =&J1 Bit 1Reserved Bit 2CTS behavior (&Rn) 0 =CTS tracks RTS (&R0) 1 =CTS always on (&R1) (Default.) Bits 3-4DTR behavior (&Dn) 0 =&D0 selected 1 =&D1 selected 2 =&D2 selected (Default.) 3 =&D3 selected Bit 5RLSD (DCD) behavior (&Cn) 0 =&C0 selected 1 =&C1 selected (Default.) Bit 6DSR behavior (&Sn) 0 =&S0 selected (Default.) 1 =&S1 selected Bit 7Long space disconnect (Yn) 0 =Y0 (Default.) 1 =Y1 - - * 52 (34h) S22 Accepted but ignored. - - * 117 (75h) Chapter 7 Special Features: Modem Emulation Register Function Range Units Saved Default S23 General Bit Mapped Options Status Indicates the status of command options. Default:62 (3Dh) (00111110b) Bit 0Grant RDL 0 =RDL not allowed (&T5) (Default.) 1 =RDL allowed (&T4) Bits 1-3DTE Rate 0 =0 - 300 bps 1 =600 bps 2 =1200 bps 3 =2400 bps 4 =4800 bps 5 =9600 bps 6 =19200 bps 7 =38400 bps or higher (Default.) Bits 4-5Assumed DTE parity 0 =even 1 =not used 2 =odd 3 =none (Default.) Bits 6-7not action applied S24 Accepted but ignored. 0-255 s S25 Delay to DTR Off Sets the length of time that the modem will ignore DTR for taking the action specified by &Dn. Its units are seconds for synchronous modes and one hundredths of a second for other modes 0-255 s or 0.01 s 5 S26 RTS-to-CTS Delay Sets the time delay, in hundredths of a second, before the modem turns CTS ON after detecting an OFF-to-ON transition on RTS when &R0 is commanded. Pertains to synchronous operation only. 0-255 0.01 s 1 S27 General Bit Mapped Options Status - - * 73 (49h) S28 Accepted but ignored. - - * 0 S29 Accepted but ignored. 0-255 10 ms 70 S30 Accepted but ignored. 0-255 10 s 0 S31 Accepted but ignored. - - S32 XON Character 0-255 ASCII 17 (11h) S33 XOFF Character 0-255 ASCII 19 (13h) S34 S35 Reserved - - - S36 Accepted but ignored. - - Chapter 7 Special Features: Modem Emulation * 62 (3Dh) * 0 * * 194 (C2h) 7 55 Register S37 General Bit Mapped Options Status Telnet support for modem emulation. Default:0 Bit 0-1 Send TCP transmit data timer 0 = 100ms 1 = 200 ms 2 = 300 ms 3 = 500 ms Bits 2-3 Service TCP transmit data watermark 0 = 256 1 = 512 2 =768 3 =1024 Bits 4-5 Service TCP receive data watermark 0 = 256 1 = 512 2 =768 3 =1024 Bits 6-7 Telnet support (RFC 2217) 0 = Disabled 1 = Receive Telnet support enabled 2 = Transmit Telnet support enabled 3 = Receive and Transmit Telnet support enabled Range Units - - Saved * Default 0 S38 Accepted but ignored. 0-255 s S39 Flow Control Bit Mapped Options Status Default:3 (00000011b) Bits 0-2Status of command options 0 =No flow control 3 =RTS/CTS (&K3) (Default.) 4 =XON/XOFF (&K4) 5 =Transparent XON (&K5) 6 =Both methods (&K6) Bits 3-7Reserved - - * 3 S40 Accepted but ignored. - - * 104 (68h) S41 Accepted but ignored. - - * 195 (C3h) Reserved - - S46 Accepted but ignored. - - * 138 S48 Accepted but ignored. - - * 7 S82 Accepted but ignored. - - 128(40h) S86 Accepted but ignored. 0-255 - - S42 - S45 56 Function 20 - Chapter 7 Special Features: Modem Emulation Register Function Range Units Saved Default S91 Accepted but ignored. 0-15 dBm 10 (Country dependent) S92 Accepted but ignored. 0-15 dBm 10 (Country dependent) S95 Accepted but ignored. - - * 0 * Register value may be stored in one of two user profiles with the &W command. Result Codes Short Long Form Short Long Form Short Long Form 0 OK 13 CONNECT 7200 84 CONNECT 33600 1 CONNECT 14 CONNECT 12000 91 CONNECT 31200 2 RING 15 CONNECT 14400 165 CONNECT 32000 3 NO CARRIER 16 CONNECT 19200 166 CONNECT 34000 4 ERROR 17 CONNECT 38400 167 CONNECT 36000 5 CONNECT 1200 18 CONNECT 57600 168 CONNECT 38000 6 NO DIALTONE 19 CONNECT 115200 169 CONNECT 40000 7 BUSY 20 CONNECT 230400 170 CONNECT 42000 8 NO ANSWER 59 CONNECT 16800 171 CONNECT 44000 9 CONNECT 0600 61 CONNECT 21600 172 CONNECT 46000 10 CONNECT 2400 62 CONNECT 24000 173 CONNECT 48000 11 CONNECT 4800 63 CONNECT 26400 174 CONNECT 50000 12 CONNECT 9600 64 CONNECT 28800 Chapter 7 Special Features: Modem Emulation 57 58 Chapter 7 Special Features: Modem Emulation Chapter 8 Special Features: Power Over the Serial Ports Serial Power Feature The Serial Power feature available for the Digi One TS, PortServer TS 2 MEI, and PortServer TS 4 MEI allows the Digi device to power a serial device (power out) or use a serial device to power the Digi device (power in). The advantage of this feature is to eliminate an external power supply. Power out is available on all ports through Ring Indicator (RI) or Data Terminal Ready (DTR). Power in is available only through RI and only on port one (1). The Serial Power feature is active on a specific port when that port is configured for RS 232 operation. • The power out budget equals one (1) watt (the total amount of power available). The available power can be divided in any combination between the ports but the following rules must be observed: — RI = 5 volts @ up to 200 mA (max) — DTR = 9 volts @ up to 100 mA (max) — You may use DTR or RI as the source of power (power out) on any port but you may not use both DTR and RI on the same port. • Pinout information — RI is pin 1 — DTR is pin 9 • RI signaling is lost when the pin is used for power Configuring RI Power RI Power In Ring Indicator (RI) power in accepts power into the Digi device server only on port one. Power in is available using the RI pin. The Digi device requires power in the range of 9-30 VDC @ 525mA (max). Ports 2, 3, and 4 can still supply power to a serial device through the RI or DTR pins for each port. When using power in through the RI, the external power supplies (both powered Ethernet and the barrel connector power supply) are inoperative. Altpin will not work for RI power in. Chapter 8 Special Features: Power Over the Serial Ports 59 1. Open the device unit enclosure and move the black jumper to the following settings: P-6 jumper on pins 1 and 2 Note: When the jumper is placed correctly for power in, the jumper will set on the pins closest to the edge of the board. The left arrow indicates the open pin and the right arrow is pointing to the jumper. 2. Close the device unit enclosure. RI Power Out Ring Indicator (RI) power out is available on all ports. The total power budget for this feature is one (1) watt not to exceed 5 volts @ up to 200mA on any single port. The following procedure assumes the unit will only be used for RI power out. 1. Set the port DIP switches to the following places: switch 1 and 3 are up and 2 and 4 are down (see "Serial Power Table" on page 61 for illustration). 2. Enable the RI power through the web interface. 3. Connect power supply with the barrel-connector power supply provided with the device or use powered Ethernet. Note: If the unit will be used with RI power in (port 1 only), set the jumper to the following setting: P-6 jumper on pins 1and 2 and do not use an external power source. Port 1 cannot be used for both power in and power out. Configuring DTR Power Power Out Data Terminal Ready (DTR) power out is the factory default on the Digi device server. Total power budget for this feature is one watt not to exceed 9 volts @ up to 100mA to any single port. 1. Set the port DIP switches to EIA 232 (switch 1 is up, 2,3, and 4 are down) to enable DTR power. 60 Chapter 8 Special Features: Power Over the Serial Ports 2. Open the port and set DTR high. Note Here are the pins to verify the jumper position. The default position has the jumper on the two pins furthest from the edge. DO NOT MOVE THE JUMPER FROM THE DEFAULT UNLESS USING RI POWER IN. If you are having trouble with your unit after using the Power over port feature, you may have tripped the circuit breaker in the unit. You can identify this by the RI or DTR signal indicators found in the System Information under Administration on the main menu in the web interface. Click the port number using serial power. (Remember serial power out is unavailable if the MEI settings are not 232.) Under serial power will be a message if the breaker is tripped. Follow the instructions to reset. From the command line use the two examples below for additional information. display circuitbreaker Display the status of the circuit breaker set configuration circuitbreaker=reset Reset the circuit breaker Note: set configuration print will also give the status of the circuitbreaker state. Serial Power Table Use this table for summary information for a serial power setup. Chapter 8 Special Features: Power Over the Serial Ports 61 . Quick Summary Table for Setup of Serial Power DTR Power RI Power OUT OUT IN DTR ON DTR OFF DTR OFF Switch Settings DTR setting 1*, 2, 3, 4 62 1 Ports Allowed 1, 2, 3, 4 *unless port 1 is used for power in Jumper Pin Settings P-6 jumper on pins 2&3 (Factory Default) P-6 jumper on pins 2&3 (Factory Default) P-6 jumper on pins 1&2 Power Budget 9v @ up to 100mA one watt 5v @ up to 200 mA one watt 9 -30 v @ up to 525mA (max) Chapter 8 Special Features: Power Over the Serial Ports Special Features: IA (Industrial Automation) Chapter 9 Industrial Automation (IA) uses the Modbus protocol that defines how devices in an IA environment communicate. It specifies that a controlling unit, called a master, manages one or more units, called slaves. Only the master may initiate communication, and slaves may only respond. Some of the elements of communication between devices that are defined by the Modbus protocol include: • The structure of Modbus messages • How the master requests information from the slave or specifies an action for the slave to take • How the slave is to respond • Addressing conventions • Handling of many of the other details required for communication to occur. Modbus defines two encoding schemes: Modbus ASCII and Modbus RTU. Each Modbus device uses one or the other. Designed to function over a serial communication cable, Modbus has been extended in recent years to function over an Ethernet network using Modbus/TCP, which defines a method of encapsulating Modbus ASCII or Modbus RTU messages in IP packets for transport over the network. The extermely flexible Digi implementation includes support for Modbus ASCII, Modbus RTU, Modbus/TCP, and two other methods of transport over a network, TCP socket and UDP socket communication. The implementation enables multiple network-based masters to concurrently initiate communication with serial-based slaves using any of the supported network protocols. Configuring Industrial Automation with Modbus 1. Click Serial Port > Change profile and select Industrial Automation. 2. Click Apply. 3. Under Profile settings, click change protocol. 4. Select the protocol that best matches your environment (master or slave) Use the Help button for additonal information. 5. Enter the User defined protocol settings (Start delimiter, end delimiter, Message timeout, and Process ANSI escape characters) and click Apply. 6. Click Packet Routing > Add. 7. Enter the packet routing information. Click the Help button for additional information. Note: Chapter 9 Configure the serial port for the serial communication parameters (baud rate, data bits, parity and stop bits) required by the connected IA device. If you configure the port for a slave, you do not have to configure a network-based master. Communication with the master just works. (If the master is Special Features: IA (Industrial Automation) 63 connected to a serial port, it must be configured, however.) If you configure a port for a master and the slaves are located on the network, TCP sockets, UDP sockets, and Modbus/TCP are all supported. Use the protocol required by the master. 64 Chapter 9 Special Features: IA (Industrial Automation) Special Features: SNMP Chapter 10 This chapter describes the configuring SNMP, the network management protocol that governs the exchange between nodes and stations. About SNMP and the Device Server Agent This section introduces SNMP and network management in TCP/IP networks and it describes the device server agent. It discusses the following: • Network management components • SNMP agent • SNMP traps • MIB support of the device server agent • Support traps of the device server agent Network Management Components The TCP/IP network management architecture contains the following components: • Managed nodes such as host systems, routers, terminal and communications servers (such as device server) and other network devices. • One or more network managers (also called network management stations), which are the points from which the network is managed • Agents that reside on managed nodes and retrieve management information and communicate this information to network managers. • The network management protocol, SNMP, which governs the exchange of information between the nodes and stations. • Management information, which is the database of information about managed objects. This database is called the management information base (MIB). SNMP Management Agent Each managed node contains at least one agent—a component that responds to requests from the network manager—that retrieves network management information from its node and notifies the manager when significant events occur. SNMP Traps A mechanism defined by SNMP is called a trap, which is a report or “alarm” from a managed node to an SNMP manager that a significant event has occurred. MIB Support The SNMP management agent supports the following MIBs: Chapter 10 Special Features: SNMP 65 • • • • Read-write for MIB II (RFC 1213), which is an Internet-standard MIB, consisting of managed objects from the systems, interfaces, IP, ICMP, TCP, UDP, transmission, and SNMP group Read-write for the character-stream devices using SMIv2 MIB (RFC 1658) Read-write for the RS-232-like hardware devices MIB (RFC 1659) Read-write for the device server IP Network Control Protocol of the Point-to-Point Protocol MIB (RFC 1473) Message Support The SNMP agent supports the Set, Get, GetNext, and Trap messages as defined in RFC 1157. These messages are used as follows: • Set, which means set the value of a specific object from one of the supported MIBs • Get, which means retrieve the value of a specific object form one of the supported MIBs • GetNext, which means retrieve the value of the next object in the MIB • Trap, which means send traps to the manager when a particular type of significant event occurs Supported Traps The agent can send traps when any of the following occur: • Cold starts (device server initializes) • Authentication failures • Login attempts Configuration Procedure: Web Interface 1. Click SNMP under System from the menu. 2. Fill in the configuration fields and click Apply to save settings. 3. Click Reboot for changes to take effect. 66 Chapter 10 Special Features: SNMP Configuration Management Chapter 11 This chapter describes configuration-management activities, including firmware upgrades and restoring the device configuration to defaults. Upgrading the Firmware Firmware upgrades can be performed from the web interface, using HTTP or FTP. HTTP or TFTP Upgrade Procedure If your hardware is okay, make sure you are running the latest firmware version available. Check the Digi Support site for the latest firmware and/or POST updates for your device: http://ftp.digi.com/support/firmware 1. Download a copy of the firmware file. 2. Access the Digi device server’s web interface by entering the Digi device server’s IP address in a browser’s URL window and log on (User Name root, Password dbps). 3. Choose Update Firmware under Administration from the main menu. Do not leave your browser until you are prompted to reboot. 4. Browse to the location on your system where the firmware has been saved, select the correct file, and click Update. 5. Reboot the device when prompted. 6. Access the Digi device server’s web interface and verify on the Information Page that the Firmware version has been successfully updated. Copying the Configuration to and from a Remote Host You can copy the configuration to a remote host and from a remote host, which means you can configure the Digi device remotely by entering commands in a text file and then copying the file to the Digi device. When To Use Remote Configuration Typically, you use remote configuration when you have several device servers with similar configurations and want to keep a master configuration on a remote host, from which you can easily create variations for downloading to individual device servers. Download Procedure 1. Access the web interface by entering the device server IP address in a browser’s URL window. 2. Log on to the device server as root. The default password is dbps. 3. From the main menu, choose Backup/Restore > Backup File. 4. Enter the location to save the file and click Save. 5. Access the device to configure. 6. Click Backup/Restore > Restore. Chapter 11 Configuration Management 67 7. Enter the location of the configuration file saved in step 4 and click Open. TFTP Procedure 1. Ensure that TFTP is running on the remote host. 2. Access the web interface by entering the device server IP address in a browser’s URL window. 3. Log on to the device server as root. The default password is dbps. 4. From the main menu, choose Backup/Restore > TFTP Server. 5. Enter the name of the file and the IP address of the TFTP server and click Backup (to save the file) or Restore to apply the file. Resetting Configuration to Defaults To reset the configuration to defaults, follow these steps: Note: The reset procedure causes the Digi device to lose all configuration changes. If you have a complex configuration, contact Digi before performing for information on saving your configuration. See "Reference and Certifications" on page 69 for information. 1. Use a pen, the point of a paper clip, or some other device to press the recessed button on the front panel. 2. While holding down the button, power on the Digi device. 3. When the 1-5-1 LED pattern is displayed, release the button. Note: It may take approximately two minutes for the device to boot up. The device boots up. 68 Chapter 11 Configuration Management Reference and Certifications Chapter 12 Interpreting the LEDs LEDs LED Power Radio Signal Strength Status (Link) ACT Color Green (labeled PWR) Yellow State On Power detected Steady blinking Waiting for an IP address Blinking 1-1-1 Starting the EOS Blinking 1-3-1 Starting the TFTP process Blinking 1-5-1 Configuration returned to factory defaults Off No power detected Varying brightness Signal strength relates to brightness or dimness of the light On Physical network detected Off No physical network detected On Bad initialization Off Ready Blinking Network activity Green Yellow Indicates LED Diagnostics LED Activity Indication 1-1-1 pattern Starting the EOS. 1-3-1 pattern TFTP boot process started. 1-5-1 pattern Tells you that configuration has been return to the factory configuration. See "Configuration Management" on page 67. 9-1-1 pattern Contact Tech Support for help. 1-952-912-3444 or outside the U.S. (+011) 952-912-3444 Steady blinking Device seeking an IP address from DHCP server. Solid On Digi One RealPort and PortServer TS 2/4 devices, this means the boot completed sucessfully. Chapter 12 Reference and Certifications 69 Device EIA 232/422/485 Switch Settings Note: MEI Switch settings apply only to Digi One TS, PortServer TS 2/4 MEI, and the Wireless Family. Switch Settings Function 1 2 3 4 EIA-232 Up Down Down Down EIA-422/485 Full-duplex Down Up Down EIA-485 half-duplex Down Down Up If up, termination. If down, no termination RJ-45 Pinouts RJ-45 Pin EIA-232 EIA-422/485 Full-Duplex EIA-485 HalfDuplex 1 RI TxD- TxD- 2 DSR RxD- RxD- 3 RTS RTS+ NA 4 GND GND GND 5 TxD TxD+ TxD+ 6 RxD RxD+ RxD+ 7 SG SG SG 8 CTS CTS+ NA 9 DTR RTS- NA 10 DCD CTS- NA Safety Statements PortServer TS 8/16 WARNING: To prevent electric shock, do not remove the cover of this module while unit is powered up. There are no user-serviceable parts inside. Refer servicing to qualified personnel. CAUTION: This unit has two power inputs. For total isolation from electrical shock and energy hazard, disconnect both power inputs. The device is intended to be mounted in an indoor only type system. 70 Chapter 12 Reference and Certifications Rack Mounting Installation (PortServer TS 16 Rack and DC Rack) • • • • • • • • • • Distribute weight evenly in the rack to avoid overloading. Ensure proper ventilation with at least 12 inches (30 centimeters) of clearance on all sides. Check equipment nameplate ratings before connecting to the supply circuit to avoid overloads which may damage over-current protection devices and supply wiring. Maintain reliable earthing for rack-mounting equipment, especially for supply connections. Install equipment in Restricted Access Areas only (dedicated equipment rooms/closets) in accordance with Articles 110-16, 110-17, and 110-18 of the National Electrical Code, ANSI/NFPA 70. Connect equipment to a DC supply source (reliably earthed) that is electrically isolated from the AC source. Directly connect the equipment chassis to the DC supply systemgrounding electrode conductor or a bonding jumper from a grounding terminal bar (or bus) that is connected to the DC supply system grounding electrode conductor. Contain equipment that has a connection between the grounded conductor of the same DC supply circuit, the grounding conductor, and also the point of grounding of the DC system in the same immediate area. Do not ground the equipment elsewhere. Locate the DC supply source within the same premises as the equipment. Route away and secure all DC input wiring from sharp edges to prevent chaffing as well as provide strain relief. Provide a readily accessible disconnect device and protective device a fixed wiring for a DC power supply suitable for the specified rated voltage and current. Disconnect and protective devices to be rated 2A Amps maximum. PortServer TS 1/3 + Modem To avoid contact with electrical current: • Never install electrical wiring during an electrical storm. • Never install telephone jacks in wet locations unless that jack is specifically designed for wet locations. • Use caution when installing or modifying telephone lines. • Use a screwdriver and other tools with insulated handles. • You and those around you should wear safety glasses or goggles. • Do not place telephone wiring or connections in any conduit, outlet or junction box containing electrical wiring. Chapter 12 Reference and Certifications 71 Do not work on your telephone wiring if you wear a pacemaker. Telephone lines carry electrical current. • • • • • Installation of inside wire may bring you close to electrical wire, conduit, terminals and other electrical facilities. Extreme caution must be used to avoid electrical shock from such facilities. You must avoid contact with all such facilities. Telephone wiring must be at least 6 feet from bare power wiring or lightning rods and associated wires, and at least 6 inches from other wire (antenna wires, doorbell wires, wires from transformers to neon signs), steam or hot water pipes, and heating ducts. Before working with existing inside wiring, check all electrical outlets for a square telephone dial light transformer and unplug it from the electrical outlet. Failure to unplug all telephone transformers can cause electrical shock. Do not place a jack where it would allow a person to use the telephone while in a bathtub, shower, swimming pool, or similar hazardous location. Protectors and grounding wire placed by the service provider must not be connected to, removed, or modified by the customer. Do not touch uninsulated telephone wiring if lightning is likely! Important! External Wiring Any external communications wiring you may install needs to be constructed to all relevant electrical codes. In the United States this is the National Electrical Code Article 800. Contact a licensed electrician for details. Specifications PortServer TS 8/16 Power Requirements (Standard Models) 2-contact barrel connector +9 to +30 VDC 525 mA (max) external power supply Environmental PortServer TS 8 Ambient temperature Relative humidity 72 PortServer TS 16 0 to 50° Celsius 32 to 131° Fahrenheit 5% to 90% non-condensing Chapter 12 Reference and Certifications 0 to 12,000 feet 0 to 3,658 meters Altitude Mechanical PortServer TS 8 PortServer TS 16 Length 21.08 centimeters 8.3 inches 34.04 centimenters 13.4 inches Width 9.4 centimeters 3.7 inches 16.76 centimenters 6.6 inches Height 2.54 centimeters 1 inches 4.06 centimenters 1.6 inches Weight .227 Kilos 3.05 lbs 2.4 Kilos 5.3 lbs Digi One TS Wireless, PortServer TS 2/4 Wireless Power Requirements (Standard Models) 2-contact barrel connector +9 to +30 VDC 525 mA (max) external power supply Environmental Ambient temperature 0 to 50° Celsius 32 to 131° Fahrenheit Relative humidity 5% to 90% non-condensing Altitude 0 to 12,000 feet 0 to 3,658 meters Mechanical Chapter 12 Reference and Certifications Length 13.31 centimeters 5.42 inches Width 8.46 centimeters 3.3 inches Height 2.42 centimeters .952 inches Weight 64 grams 2.25 ounces 73 PortServer TS 2/4 MEI, Digi One TS Power Requirements (Standard Models) 2-contact barrel connector +9 to +30 VDC 525 mA (max) external power supply Environmental Ambient temperature 0 to 50° Celsius 32 to 122° Fahrenheit Ambient temperature for TS H models -35 to 70° Celsius -31 to 158° Fahrenheit Relative humidity 5% to 90% non-condensing Altitude 0 to 12,000 feet 0 to 3,658 meters Mechanical Length 13.31 centimeters 5.42 inches Width 8.46 centimeters 3.3 inches Height 2.42 centimeters .952 inches Weight 64 grams 2.25 ounces PortServer TS 2/4 Power Requirements (Standard Models) 2-contact barrel connector +9 to +30 VDC 525 mA (max) external power supply Environmental 74 Ambient temperature 10 to 55° Celsius 50 to 131° Fahrenheit Ambient temperature for TS H models -25 to 70° Celsius -13 to 158 Relative humidity 5% to 90% non-condensing Chapter 12 Reference and Certifications Altitude 0 to 12,000 feet 0 to 3,658 meters Mechanical Length 13.31 centimeters 5.42 inches Width 8.46 centimeters 3.3 inches Height 2.42 centimeters .952 inches Weight 64 grams 2.25 ounces PortServer TS 1/3 + Modem • • • • • • • • • • • ITU-T V.92/V.90/56K (-92 build option) V.34/V.33.6 (-34 build option V.32 bis/14.4K (-32 build option) V.22 bis/2400 baud (-22 build option) V.22 V.23 V.21 Bell 212A and Bell 103 V.44 Error Correction V.42 LAPM, MNP 2-4 Error Correction V.42 bis and MNP Class 5 data compression Chapter 12 Reference and Certifications 75 Regulatory Notices PortServer 1/3 + Modem Electromagnetic Emissions • • • • • • FCC Part 15 Subpart B, Class B EN55022 Class B AS/NZS 3548 VCCI EN61000-3-2 EN61000-3-3 Electromagnetic Immunity • EN55024:1998 Safety • • • UL/CUL 60950-1 IEC60950 EN60950 Power Supply • 9-30 Vdc 50/60 Hz @ 15 W Digi One RealPort, Digi One TS, PortServer TS 2/4, PortServer TS 2/4 MEI, PortServer TS 16 Emission • • • • • • • FCC P15 Subpart B, Class B ICES-003, Class B EN55022:1994, Class B AS/NZS 3548 VCCI EN61000-3,2:2000 EN61000-3-3:1995 Immunity • EN55024:1998 Safety • • • • UL60950-1 CSA 22.2 No. 60950-1-03 IEC60950 EN60950 Power Supply • 9-30 Vdc 50/60 Hz @ 15 W Digi One TS Wireless, PortServer TS 2/4 Wireless 76 Emission • • • • • • • FCC P15 Subpart B, Class B ICES-003, Class B EN55022:1994, Class B AS/NZS 3548 VCCI EN61000-3,2:2000 EN61000-3-3:1995 Immunity • • EN55024:1998 EN 301 489-3 Chapter 12 Reference and Certifications Digi One TS Wireless, PortServer TS 2/4 Wireless Safety • • • • UL60950-1 CSA 22.2 No. 60950-1-03 IEC60950 EN60950 Power Supply • 9-30 Vdc 50/60 Hz @ 15 W PortServer TS 8 Emission • • • • • • • FCC P15 Subpart B, Class A ICES-003, Class A EN55022:1994, Class A AS/NZS 3548 VCCI EN61000-3,2:2000 EN61000-3-3:1995 Immunity • EN55024:1998 Safety • • • • UL60950-1 CSA 22.2 No. 60950-1-03 IEC60950 EN60950 Power Supply • 9-30 Vdc 50/60 Hz @ 15 W Digi One TS, PortServer TS 2/4, PortServer TS 2/4 MEI, PortServer TS 16 Chapter 12 Reference and Certifications Emission • • • • • • • FCC P15 Subpart B, Class B ICES-003, Class B EN55022:1994, Class B AS/NZS 3548 VCCI EN61000-3,2:2000 EN61000-3-3:1995 Immunity • EN55024:1998 Safety • • • • UL60950-1 CSA 22.2 No. 60950-1-03 IEC60950 EN60950 Power Supply • 9-30 Vdc 50/60 Hz @ 15 W 77 Certifications FCC Part 15 Class A (PortServer TS 8) Radio Frequency Interference (RFI) (FCC 15.105) This equipment has been tested and found to comply with the limits for Class A digital devices pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential environment. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try and correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and the receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Labeling Requirements (FCC 15.19) This device complies with Part 15 of FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Modifications (FCC 15.21) Changes or modifications to this equipment not expressly approved by Digi may void the user's authority to operate this equipment. Cables (FCC 15.27) Shielded cables must be used to remain within the Class A limitations. ICES 003 Class B ( Digi One TS, Digi One TS Wireless, PortServer TS 2/4, PortServer TS 2/4 MEI, PortServer TS 2/4 Wireless, PortServer TS 16) This digital apparatus does not exceed the Class B limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications. Le present appareil numerique n'emet pas de bruits radioelectriques depassant les limites applicables aux appareils numeriques de la class B prescrites dans le Reglement sur le brouillage radioelectrique edicte par le ministere des Communications du Canada. Antennae (Wireless only) Digi Wireless products can only use the Digi antennae provided in the box. 78 Chapter 12 Reference and Certifications Maximum Permissible Exposure (Wireless only) To comply with Maximum Permissible Exposure requirements, antennas must be installed to provide at least 20 cm of separation from all persons per FCC 47 CFR 2.1091. Declaration of Conformity (in accordance with FCC Dockets 96-208 and 95-19) Digi International declares, that the product: Manufacturer’s Name: Corporate Headquarters: Manufacturing Headquarters: Digi International 11001 Bren Road East Minnetonka MN 55343 10000 West 76th Street Eden Prairie MN 55344 Product Name: Digi One TS Digi One TS (High temperature model) PortServer TS 2 (High temperature model) PortServer TS 4 (High temperature model) PortServer TS 2 PortServer TS 4 PortServer TS 2 MEI PortServer TS 4 MEI PortServer TS 1+Modem PortServer TS 3+Modem Digi One TS Wireless PortServer TS 2 Wireless PortServer TS 4 Wireless PortServer TS 16 PortServer TS 16 Rack PortServer TS 16 DC Rack Model Numbers: 50000836-01 50000837-01 50000837-02 50000837-03 50000723-02 50000723-03 50000836-02 50000836-03 50000836-05 50000836-06 50000836-10 50000836-11 50000836-12 50001207-01 50000854-01 50000722-01 to which this declaration relates, meets the requirements specified by the Federal Communications Commission as detailed in the following specifications: • Part 15, Subpart B, for Class B Equipment • FCC Docket 96-208 as it applies to Class B personal • Computers and Peripherals The product listed above has been tested at an External Test Laboratory certified per FCC rules and has been found to meet the FCC, Part 15, Class B, Emission Limits. Documentation is on file and available from the Digi International Homologation Department. Chapter 12 Reference and Certifications 79 Digi Contact Information Digi International 11001 Bren Road East Minnetonka, MN 55343 U.S.A. Digi Contacts 80 World Wide Web: http://digi.com email digi.info@digi.com Telephone (U.S.) 1-952-912-3444 Telephone (other locations) (+011) 952-912-3444 Chapter 12 Reference and Certifications


Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Modify Date                     : 2004:01:26 12:17:39-06:00
Create Date                     : 2004:01:26 09:38:04Z
Creator                         : FrameMaker 7.0
Author                          : Digi International
Keywords                        : 90000583_A
Page Count                      : 80
Creation Date                   : 2004:01:26 09:38:04Z
Mod Date                        : 2004:01:26 09:38:04Z
Producer                        : Acrobat Distiller 5.0.5 (Windows)
Metadata Date                   : 2004:01:26 09:38:04Z
Title                           : Untitled Document
Page Mode                       : UseNone
EXIF Metadata provided by EXIF.tools

Navigation menu