Digi XBEEPRO2 XBEE PRO SERIES 2 OEM RF MODULE User Manual USERS MANUAL
Digi International Inc XBEE PRO SERIES 2 OEM RF MODULE USERS MANUAL
Digi >
Contents
- 1. USERS MANUAL
- 2. Revised Used Manual
USERS MANUAL
XBee™ Series 2/XBee™ Series 2 PRO OEM RF Modules XBee Series 2/Series 2 PRO PRO OEM RF Modules ZigBee™ Networks RF Module Operation RF Module Configuration Appendices Product Manual v1.x.2x - ZigBee Protocol For OEM RF Module Part Numbers: XB24-BxIT-00x ZigBee OEM RF Modules by Digi International Firmware Versions: 1.0xx 1.1xx 1.2xx 1.3xx Coordinator, Transparent Operation Coordinator, API Operation Router, End Device, Transparent Operation Router, End Device, API Operation Digi International Inc. 11001 Bren Road East Minnetonka, MN 55343 877 912-3444 or 952 912-3444 http://www.digi.com 90000866_B 2007.010.031 XBee Series 2/Series 2 PRO OEM RF Modules‐ ZigBee ‐ v1.x2x [2007.010.031] © 2007 Digi International, Inc. All rights reserved No part of the contents of this manual may be transmitted or reproduced in any form or by any means without the written permission of Digi International, Inc. ZigBee® is a registered trademark of the ZigBee Alliance. XBee™ Series 2/XBee™ Series 2 PRO is a trademark of Digi International, Inc. Technical Support: Phone: (801) 765‐9885 Live Chat: www.digi.com E‐mail: support@digi.com © 2007 Digi International, Inc. ii XBee Series 2/XBee Series 2 PRO OEM RF Modules ‐ ZigBee ‐ v1.x2x Contents 1. XBee Series 2 OEM RF Modules 1.1. Key Features 1.2. Specifications 4.3.2. Parent Operation 1.6. Electrical Characteristics 5.3. Loopback Testing 2. RF Module Operation 2.1.2. Serial Buffers 5.3.1. AT Firmware 5.3.2. API Firmware 5.4. Join Indicators 2.1.5. API Operation 10 Sleep Mode 7.0.2. API Frames 13 14 56 8.0.1. Starting an XBee Network 56 8.0.2. AT Command Programming Examples 57 3. ZigBee Networks 17 3.1. ZigBee Network Formation 17 19 9.3. XBee Series 2 Custom Bootloader 19 3.2.2. ZigBee Application-layer Addressing 3.2.3. Data Transmission and Routing 19 20 4. XBee Series 2 Networks 25 4.1. XBee Series 2 Network Formation 59 9.2. Customizing XBee Default Parameters 59 18 3.2. ZigBee Network Communications 3.2.1. ZigBee Device Addressing 57 9.1. Interoperability with other EM250 Devices 59 17 3.1.3. Joining an End Device 8.0.3. API Programming Examples 9. Manufacturing Support 17 3.1.1. Starting a ZigBee Coordinator 25 4.1.1. Starting an XBee Series 2 Coordinator 25 4.1.2. Joining an XBee Series 2 Router to an existing PAN 25 4.1.3. Joining an XBee Series 2 End Device to an Existing PAN 25 Network Reset 43 44 8. Examples 15 3.1.2. Joining a Router 43 7.0.1. API Frame Specifications 14 2.2.4. Command Mode 35 36 7. API Operation 13 13 2.2.3. Receive Mode 35 35 6. XBee Series 2 Command Reference Tables37 12 12 2.2.2. Transmit Mode 35 5.6. Battery Life Monitoring 2.1.4. Transparent Operation 2.2. Modes of Operation 35 35 5.5. Manual Device Identification 2.1.3. Serial Flow Control 4.1.4. 35 5.2. Remote Configuration 2.1.1. UART Data Flow 32 35 5.1. Device Discovery 2.1. Serial Communications 32 5. Advanced Features 1.4. Mounting Considerations 2.2.5. 32 32 4.4. I/O Line Configuration 1.3. Mechanical Drawings 2.2.1. Idle Mode 4.3. Sleep Mode Operation 4.3.1. End Device Operation 1.1.1. Worldwide Acceptance 1.5. Pin Signals 59 9.4. Programming XBee Series 2 Modules 9.5. XBee EM250 Pin Mappings 59 59 Appendix A:Definitions 61 Appendix B: Agency Certifications 63 Appendix C:Migrating from the 802.15.4 Protocol 67 Appendix D:Development Guide 68 Appendix E:Additional Information 78 26 4.2. XBee Series 2 Addressing 4.2.1. Device Addressing 27 27 4.2.2. Application-layer Addressing 29 4.2.3. XBee Series 2 Binding Table 29 4.2.4. XBee Series 2 Endpoint Table 31 © 2007 Digi Internaitonal, Inc. iii 1. XBee Series 2/XBee Series 2 PRO OEM RF Modules The XBee Series 2 PRO OEM RF Modules were engineered to operate within the ZigBee protocol and support the unique needs of low-cost, low-power wireless sensor networks. The modules require minimal power and provide reliable delivery of data between remote devices. The modules operate within the ISM 2.4 GHz frequency band. 1.1. Key Features High Performance, Low Cost • Indoor/Urban: up to 300’ (100 m) Low Power XBee Series 2 PRO • Outdoor line-of-sight: up to 1 mile (1.6 km) • TX Current: 295 mA (@3.3 V) • Transmit Power Output: 100 mW (20 dBm) EIRP • RX Current: 45 mA (@3.3 V) • Receiver Sensitivity: -102 dBm RF Data Rate: 250,000 bps Advanced Networking & Security Retries and Acknowledgements DSSS (Direct Sequence Spread Spectrum) Each direct sequence channel has over 65,000 unique network addresses available • Power-down Current: < 1 µA @ 25oC Easy-to-Use No configuration necessary for out-of box RF communications AT and API Command Modes for configuring module parameters Small form factor Extensive command set Point-to-point, point-to-multipoint and peer-to-peer topologies supported Free X-CTU Software (Testing and configuration software) Self-routing, self-healing and fault-tolerant mesh networking Free & Unlimited Technical Support 1.1.1. Worldwide Acceptance FCC Approval (USA) Refer to Appendix A [p50] for FCC Requirements. Systems that contain XBee Series 2/XBee Series 2 PRO RF Modules inherit Digi Certifications. ISM (Industrial, Scientific & Medical) 2.4 GHz frequency band Manufactured under ISO 9001:2000 registered standards XBee Series 2/XBee Series 2 PRO RF Modules are optimized for use in US, Canada, Australia, Israel and Europe (contact MaxStream for complete list of agency approvals). © 2007 Digi International, Inc. XBee Series 2/XBee Series 2 PRO OEM RF Modules ‐ ZigBee ‐ v1.x2x 1.2. Specifications Table 1‐01. Specifications of the XBee Series 2/XBee Series 2 PRO OEM RF Module Specification XBee Series 2 XBee Series 2 PRO Indoor/Urban Range up to 133 ft. (40 m)* up to 300 ft. (100 m)* Outdoor RF line-of-sight Range up to 400 ft. (120 m)* up to 1 mile (1.6 km) Transmit Power Output (software selectable) 2mW (+3dBm), boost mode enabled 1.25mW (+1dBm), boost mode disabled 79mW (+19 dBm) RF Data Rate 250,000 bps 250,000 bps Serial Interface Data Rate (software selectable) 1200 - 230400 bps (non-standard baud rates also supported) 1200 - 230400 bps (non-standard baud rates also supported) Receiver Sensitivity -96 dBm, boost mode enabled -95 dBm, boost mode disabled -102 dBm Supply Voltage 2.1 - 3.6 V 3.0 - 3.4 V Operating Current (Transmit, max output power) 40mA (@ 3.3 V, boost mode enabled) 35mA (@ 3.3 V, boost mode disabled) 295mA (@3.3 V) Operating Current (Receive)) 40mA (@ 3.3 V, boost mode enabled) 38mA (@ 3.3 V, boost mode disabled) 45 mA (@3.3 V) Idle Current (Receiver off) 15mA 15mA Performance Power Requirements < 1 uA @ 25 < 1 uA @ 25oC Operating Frequency Band ISM 2.4 GHz ISM 2.4 GHz Dimensions 0.960” x 1.087” (2.438cm x 2.761cm) 0.960" x 1.297" (2.438cm x 3.294cm) Operating Temperature -40 to 85º C (industrial) -40 to 85º C (industrial) Antenna Options Integrated Whip, Chip, RPSMA, or U.FL Connector* Integrated Whip, Chip, RPSMA, or U.FL Connector* Supported Network Topologies Point-to-point, Point-to-multipoint, Peer-to-peer, and Mesh Point-to-point, Point-to-multipoint, Peer-to-peer, and Mesh Number of Channels (software selectable) 16 Direct Sequence Channels 14 Direct Sequence Channels Addressing Options PAN ID and Addresses, Cluster IDs and Endpoints (optional) PAN ID and Addresses, Cluster IDs and Endpoints (optional) United States (FCC Part 15.247) OUR-XBEE2 MCQ-XBEEPRO2 Industry Canada (IC) 4214A-XBEE2 1846A-XBEEPRO2 Europe (CE) ETSI ETSI Power-down Current oC General Networking & Security Agency Approvals © 2007 Digi International, Inc. XBee Series 2/XBee Series 2 PRO OEM RF Modules ‐ ZigBee ‐ v1.x2x 1.3. Mechanical Drawings Figure 1‐01. Mechanical drawings of the XBee Series 2/XBee Series 2 PRO OEM RF Modules (antenna options not shown) 1.4. Mounting Considerations The XBee Series 2/XBee Series 2 PRO RF Module (through-hole) was designed to mount into a receptacle (socket) and therefore does not require any soldering when mounting it to a board. The XBee Series 2 PRO Development Kits contain RS-232 and USB interface boards which use two 20pin receptacles to receive modules. Figure 1‐02. XBee Series 2 PRO Module Mounting to an RS‐232 Interface Board. The receptacles used on Digi development boards are manufactured by Century Interconnect. Several other manufacturers provide comparable mounting solutions; however, Digi currently uses the following receptacles: • Through-hole single-row receptacles Samtec P/N: MMS-110-01-L-SV (or equivalent) • Surface-mount double-row receptacles Century Interconnect P/N: CPRMSL20-D-0-1 (or equivalent) • Surface-mount single-row receptacles Samtec P/N: SMM-110-02-SM-S Digi also recommends printing an outline of the module on the board to indicate the orientation the module should be mounted. © 2007 Digi International, Inc. XBee Series 2/XBee Series 2 PRO OEM RF Modules ‐ ZigBee ‐ v1.x2x 1.5. Pin Signals Figure 1‐03. XBee Series 2/XBee Series 2 PRO RF Module Pin Number (top sides shown ‐ shields on bottom) Table 1‐02. Pin Assignments for the XBee Series 2 PRO Modules (Low‐asserted signals are distinguished with a horizontal line above signal name.) Pin # Name Direction VCC Description Power supply DOUT Output UART Data Out UART Data In DIN / CONFIG Input DIO12 Either Digital I/O 12 RESET Input Module Reset (reset pulse must be at least 200 ns) PWM0 / RSSI / DIO10 Either PWM Output 0 / RX Signal Strength Indicator / Digital IO PWM / DIO11 Either Digital I/O 11 [reserved] Do not connect DTR / SLEEP_RQ/ DIO8 Either Pin Sleep Control Line or Digital IO 8 10 GND Ground 11 DIO4 Either Digital I/O 4 12 CTS / DIO7 Either Clear-to-Send Flow Control or Digital I/O 7 13 ON / SLEEP / DIO9 Output Module Status Indicator or Digital I/O 9 14 [reserved] Do not connect 15 Associate / DIO5 Either Associated Indicator, Digital I/O 5 16 RTS / DIO6 Either Request-to-Send Flow Control, Digital I/O 6 17 AD3 / DIO3 Either Analog Input 3 or Digital I/O 3 18 AD2 / DIO2 Either Analog Input 2 or Digital I/O 2 19 AD1 / DIO1 Either Analog Input 1 or Digital I/O 1 20 AD0 / DIO0 / ID Button Either Analog Input 0, Digital I/O 0, or Node Identification Design Notes: • Minimum connections: VCC, GND, DOUT & DIN • Minimum connections to support serial firmware upgrades: VCC, GND, DIN, DOUT, RTS & DTR • Signal Direction is specified with respect to the module • Module includes a 30k Ohm resistor attached to RESET • Several of the input pull-ups can be configured using the PR command • Unused pins should be left disconnected © 2007 Digi International, Inc. XBee Series 2/XBee Series 2 PRO OEM RF Modules ‐ ZigBee ‐ v1.x2x 1.6. Electrical Characteristics Table 1‐03. Symbol DC Characteristics of the XBee Series 2 PRO (VCC = 3.0 ‐ 3.4 VDC). Parameter Condition Min Typical Max Units VIL Input Low Voltage VIH Input High Voltage All Digital Inputs 0.2 * VCC All Digital Inputs 0.8 * VCC 0.18* VCC VOL Output Low Voltage IOL = 2 mA, VCC >= 2.7 V 0.18*VCC VOH Output High Voltage IOH = -2 mA, VCC >= 2.7 V 0.82*VCC IIIN Input Leakage Current VIN = VCC or GND, all inputs, per pin 0.5uA uA © 2007 Digi International, Inc. 2. RF Module Operation 2.1. Serial Communications The XBee Series 2 OEM RF Modules interface to a host device through a logic-level asynchronous serial port. Through its serial port, the module can communicate with any logic and voltage compatible UART; or through a level translator to any serial device (For example: Through a Digi proprietary RS-232 or USB interface board). 2.1.1. UART Data Flow Devices that have a UART interface can connect directly to the pins of the RF module as shown in the figure below. Figure 2‐01. System Data Flow Diagram in a UART‐interfaced environment (Low‐asserted signals distinguished with horizontal line over signal name.) DIN (data in) DIN (data in) DOUT (data out) DOUT (data out) Serial Data Data enters the module UART through the DIN (pin 3) as an asynchronous serial signal. The signal should idle high when no data is being transmitted. Each data byte consists of a start bit (low), 8 data bits (least significant bit first) and a stop bit (high). The following figure illustrates the serial bit pattern of data passing through the module. Figure 2‐02. UART data packet 0x1F (decimal number ʺ31ʺ) as transmitted through the RF module Example Data Format is 8‐N‐1 (bits ‐ parity ‐ # of stop bits) The module UART performs tasks, such as timing and parity checking, that are needed for data communications. Serial communications depend on the two UARTs to be configured with compatible settings (baud rate, parity, start bits, stop bits, data bits). 2.1.2. Serial Buffers The XBee Series 2 modules maintain small buffers to collect received serial and RF data, which is illustrated in the figure below. The serial receive buffer collects incoming serial characters and holds them until they can be processed. The serial transmit buffer collects data that is received via the RF link that will be transmitted out the UART. © 2007 Digi International, Inc. XBee Series 2/XBee Series 2 PRO ZigBee OEM RF Modules v1.x2x Figure 2‐03. Internal Data Flow Diagram DIN Serial Receiver Buffer RF TX Buffer Transmitter RF Switch CTS Antenna Port Processor VCC GND DOUT RF RX Buffer Serial Transmit Buffer Receiver RTS Serial Receive Buffer When serial data enters the RF module through the DIN Pin (pin 3), the data is stored in the serial receive buffer until it can be processed. Under certain conditions, the module may not be able to process data in the serial receive buffer immediately. If large amounts of serial data are sent to the module, CTS flow control may be required to avoid overflowing the serial receive buffer. Cases in which the serial receive buffer may become full and possibly overflow: 1. If the module is receiving a continuous stream of RF data, the data in the serial receive buffer will not be transmitted until the module is no longer receiving RF data. 2. If the module is transmitting an RF data packet, the module may need to discover the destination address or establish a route to the destination. After transmitting the data, the module may need to retransmit the data if an acknowledgment is not received, or if the transmission is a broadcast. These issues could delay the processing of data in the serial receive buffer. Serial Transmit Buffer When RF data is received, the data is moved into the serial transmit buffer and is sent out the serial port. If the serial transmit buffer becomes full enough such that all data in a received RF packet won’t fit in the serial transmit buffer, the entire RF data packet is dropped. Cases in which the serial transmit buffer may become full resulting in dropped RF packets 1. If the RF data rate is set higher than the interface data rate of the module, the module could receive data faster than it can send the data to the host. 2. If the host does not allow the module to transmit data out from the serial transmit buffer because of being held off by hardware flow control. 2.1.3. Serial Flow Control The RTS and CTS module pins can be used to provide RTS and/or CTS flow control. CTS flow control provides an indication to the host to stop sending serial data to the module. RTS flow control allows the host to signal the module to not send data in the serial transmit buffer out the uart. RTS and CTS flow control are enabled using the D6 and D7 commands. CTS Flow Control If CTS flow control is enabled (D7 command), when the serial receive buffer is 17 bytes away from being full, the module de-asserts CTS (sets it high) to signal to the host device to stop sending serial data. CTS is re-asserted after the serial receive buffer has 34 bytes of space. © 2007 Digi International, Inc. 10 XBee Series 2/XBee Series 2 PRO ZigBee OEM RF Modules v1.x2x RTS Flow Control If flow RTS control is enabled (D6 command), data in the serial transmit buffer will not be sent out the DOUT pin as long as RTS is de-asserted (set high). The host device should not de-assert RTS for long periods of time to avoid filling the serial transmit buffer. If an RF data packet is received, and the serial transmit buffer does not have enough space for all of the data bytes, the entire RF data packet will be discarded.Transparent Operation RF modules that contain the following firmware versions will support Transparent Mode: 1.0xx (coordinator) and 1.2xx (router/end device). When operating in Transparent Mode, the modules act as a serial line replacement. All UART data received through the DIN pin is queued up for RF transmission. When RF data is received, the data is sent out the DOUT pin. The module configuration parameters are configured using the AT command mode interface. (See RF Module Operation --> Command Mode.) When RF data is received by a module, the data is sent out the DOUT pin. Serial-to-RF Packetization Data is buffered in the serial receive buffer until one of the following causes the data to be packetized and transmitted: 1. No serial characters are received for the amount of time determined by the RO (Packetization Timeout) parameter. If RO = 0, packetization begins when a character is received. 2. Maximum number of characters that will fit (72) in an RF packet is received. 3. The Command Mode Sequence (GT + CC + GT) is received. Any character buffered in the serial receive buffer before the sequence is transmitted. 2.1.4. API Operation API (Application Programming Interface) Operation is an alternative to the default Transparent Operation. The frame-based API extends the level to which a host application can interact with the networking capabilities of the module. RF modules that contain the following firmware versions will support API operation: 1.1xx (coordinator) and 1.3xx (router/end device). When in API mode, all data entering and leaving the module is contained in frames that define operations or events within the module. Transmit Data Frames (received through the DIN pin (pin 3)) include: • RF Transmit Data Frame • Command Frame (equivalent to AT commands) Receive Data Frames (sent out the DOUT pin (pin 2)) include: • RF-received data frame • Command response • Event notifications such as reset, associate, disassociate, etc. The API provides alternative means of configuring modules and routing data at the host application layer. A host application can send data frames to the module that contain address and payload information instead of using command mode to modify addresses. The module will send data frames to the application containing status packets; as well as source, and payload information from received data packets. The API operation option facilitates many operations such as the examples cited below: -> Transmitting data to multiple destinations without entering Command Mode -> Receive success/failure status of each transmitted RF packet -> Identify the source address of each received packet To implement API operations, refer to the API Operation chapter 6. © 2007 Digi International, Inc. 11 XBee Series 2/XBee Series 2 PRO ZigBee OEM RF Modules v1.x2x 2.2. Modes of Operation 2.2.1. Idle Mode When not receiving or transmitting data, the RF module is in Idle Mode. During Idle Mode, the RF module is also checking for valid RF data. The module shifts into the other modes of operation under the following conditions: • Transmit Mode (Serial data in the serial receive buffer is ready to be packetized) • Receive Mode (Valid RF data is received through the antenna) • Sleep Mode (End Devices only) • Command Mode (Command Mode Sequence is issued) 2.2.2. Transmit Mode When serial data is received and is ready for packetization, the RF module will exit Idle Mode and attempt to transmit the data. The destination address determines which node(s) will receive the data. Prior to transmitting the data, the module ensures that a 16-bit network address and route to the destination node have been established. If the 16-bit network address is not known, network address discovery will take place. If a route is not known, route discovery will take place for the purpose of establishing a route to the destination node. If a module with a matching network address is not discovered, the packet is discarded. The data will be transmitted once a route is established. If route discovery fails to establish a route, the packet will be discarded. Figure 2‐04. Transmit Mode Sequence Successful Transmission Idle Mode New Transmission 16-bit Network Address Known? Yes Transmit Data No No 16-bit Network Address Discovery 16-bit Network Address Discovered? Yes Route Known? Route Discovery Yes No Route Discovered? Yes No Data Discarded When data is transmitted from one node to another, a network-level acknowledgement is transmitted back across the established route to the source node. This acknowledgement packet indicates to the source node that the data packet was received by the destination node. If a network acknowledgement is not received, the source node will re-transmit the data. See Data Transmission and Routing in chapter 3 for more information. © 2007 Digi International, Inc. 12 XBee Series 2/XBee Series 2 PRO ZigBee OEM RF Modules v1.x2x 2.2.3. Receive Mode If a valid RF packet is received, the data is transferred to the serial transmit buffer 2.2.4. Command Mode To modify or read RF Module parameters, the module must first enter into Command Mode - a state in which incoming serial characters are interpreted as commands. Refer to the API Mode section for an alternate means of configuring modules. AT Command Mode To Enter AT Command Mode: Send the 3-character command sequence “+++” and observe guard times before and after the command characters. [Refer to the “Default AT Command Mode Sequence” below.] Default AT Command Mode Sequence (for transition to Command Mode): • No characters sent for one second [GT (Guard Times) parameter = 0x3E8] • Input three plus characters (“+++”) within one second [CC (Command Sequence Character) parameter = 0x2B.] • No characters sent for one second [GT (Guard Times) parameter = 0x3E8] All of the parameter values in the sequence can be modified to reflect user preferences. NOTE: Failure to enter AT Command Mode is most commonly due to baud rate mismatch. Ensure the ‘Baud’ setting on the “PC Settings” tab matches the interface data rate of the RF module. By default, the BD parameter = 3 (9600 bps). To Send AT Commands: Send AT commands and parameters using the syntax shown below. Figure 2‐05. Syntax for sending AT Commands To read a parameter value stored in the RF module’s register, omit the parameter field. The preceding example would change the RF module Destination Address (Low) to “0x1F”. To store the new value to non-volatile (long term) memory, subsequently send the WR (Write) command. For modified parameter values to persist in the module’s registry after a reset, changes must be saved to non-volatile memory using the WR (Write) Command. Otherwise, parameters are restored to previously saved values after the module is reset. System Response. When a command is sent to the module, the module will parse and execute the command. Upon successful execution of a command, the module returns an “OK” message. If execution of a command results in an error, the module returns an “ERROR” message. To Exit AT Command Mode: 1. Send the ATCN (Exit Command Mode) command (followed by a carriage return). 2. If no valid AT Commands are received within the time specified by CT (Command Mode Timeout) Command, the RF module automatically returns to Idle Mode. [OR] For an example of programming the RF module using AT Commands and descriptions of each configurable parameter, refer to the "Examples" and "XBee Series 2 Command Reference Tables" chapters. © 2007 Digi International, Inc. 13 XBee Series 2/XBee Series 2 PRO ZigBee OEM RF Modules v1.x2x 2.2.5. Sleep Mode Sleep modes allow the RF module to enter states of low-power consumption when not in use. To enter Sleep Mode, one of the following conditions must be met (in addition to the module having a non-zero SM parameter value): • Sleep_RQ (pin 9) is asserted • The module is idle (no data is transmitted or received) for the time defined by the ST (Time before Sleep) parameter. Table 2‐01. Sleep Mode Configurations (Router / End Device Firmware Only) Sleep Mode Setting Transition into Sleep Mode Transition out of Sleep Mode (wake) Characteristics Related Commands Power Consumption SM=1 Assert (high) Sleep_RQ (pin 9) De-assert (0V) Sleep_RQ (pin 9) Pin/Host controlled SM < 1uA SM=4 Automatic transition to sleep mode as defined by the ST parameter Transition occurs after the cyclic sleep time interval elapses. The time interval is defined by the SP (Cyclic Sleep Period) parameter. RF module wakes after a predetermined time interval to detect if RF data is present. SM, ST, SP, SN < 1uA The SM command is central to setting Sleep Mode configurations. By default, sleep modes are disabled (SM=0) and the module remains in Idle/Receive Mode. When in this state, the module is constantly ready to respond to serial or RF activity. Zigbee Protocol: Sleep Modes In the ZigBee protocol, sleep modes are only supported on end devices. See section 4.3, "Sleep Mode Operation" for more information. Pin/Host Controlled Sleep Pin sleep puts the module to sleep and wakes it from sleep according to the state of Sleep_RQ (pin 9). When Sleep_RQ is asserted (high), the module will finish any transmit or receive operations, and then enter a low power state. The module will not respond to either serial or RF activity while in sleep. To wake a module operating in pin sleep, de-assert Sleep_RQ (pin 9). The module will wake when Sleep_RQ is de-asserted and is ready to transmit or receive when the CTS line is low. When the module wakes from pin sleep, it sends a transmission to its parent router or coordinator (called a poll request) to see if it has buffered any data packets for the end device. The module will continue to poll its parent for data while it remains awake. If the parent receives an RF data packet destined for one or more of its end device children, it will transmit the packet to the end device upon receipt of a poll request. See section 4.3, "Sleep Mode Operation" for more information. Cyclic Sleep Cyclic sleep allows modules to wake periodically to check for RF data and sleep when idle. When the SM parameter is set to 4, the module is configured to sleep for the time specified by the SP parameter. After the SP time expires, the module will wake and check for RF or serial data. To check for RF data, the module sends a transmission to its parent router or coordinator (called a poll request) to see if its parent has any buffered data packets for the end device. If the parent has data for the module, the module will remain awake to receive the data. Otherwise, the module will return to sleep. (See section 4.3, "Sleep Mode Operation" for more information.) If serial or RF data is received, the module will start the ST timer and remain awake until the timer expires. While the module is awake, it will continue to send poll request messages to its parent to check for additional data. The ST timer will be restarted anytime serial or RF activity occurs. The module will resume sleep when the ST timer expires. When the module wakes from sleep, it asserts On/Sleep (pin 13) to provide a wake indicator to a host device. If a host device wishes to sleep longer than SP time or to wake only when RF data arrives, the SN command can be used to prevent On/Sleep from asserting for a multiple of SP time. For example, if SP = 20 seconds, and SN = 5, the On/Sleep pin will remain de-asserted (low) for up to 100 seconds. © 2007 Digi International, Inc. 14 XBee Series 2/XBee Series 2 PRO ZigBee OEM RF Modules v1.x2x If CTS flow control is enabled, CTS (pin 12) is asserted (0V) when the module wakes and deasserted (high) when the module sleeps, allowing for communication initiated by the host if desired. © 2007 Digi International, Inc. 15 3. ZigBee Networks 3.1. ZigBee Network Formation A ZigBee Personal Area Network (PAN) consists of one coordinator and one or more routers and/or end devices. A ZigBee Personal Area Network (PAN) is created when a coordinator selects a channel and PAN ID to start on. Once the coordinator has started a PAN, it can allow router and end device nodes to join the PAN. When a router or end device joins a PAN, it receives a 16-bit network address and can transmit data to or receive data from other devices in the PAN. Routers and the coordinator can allow other devices to join the PAN, and can assist in sending data through the network to ensure data is routed correctly to the intended recipient device. When a router or coordinator allows an end device to join the PAN, the end device that joined becomes a child of the router or coordinator that allowed the join. End devices, however can transmit or receive data but cannot route data from one node to another, nor can they allow devices to join the PAN. End devices must always communicate directly to the parent they joined to. The parent router or coordinator can route data on behalf of an end device child to ensure it reaches the correct destination. End devices are intended to be battery powered and can support low power modes. Figure 3‐01. Node Types / Sample of a Basic ZigBee Network Topology The network address of the PAN coordinator is always 0. When a router joins a PAN, it can also allow other routers and end devices to join to it. Joining establishes a parent/child relationship between two nodes. The node that allowed the join is the parent, and the node that joined is the child. The parent/child relationship is not necessary for routing data. 3.1.1. Starting a ZigBee Coordinator When a coordinator first comes up, it performs an energy scan on multiple channels (frequencies) to select an unused channel to start the PAN. After removing channels with high detected energy levels, the coordinator issues an 802.15.4 beacon request command on the remaining, low energy level channels. Nearby routers or coordinators that have already joined a PAN respond to the beacon request frame with a small beacon transmission indicating the PAN identifier (PAN ID) that they are operating on, and whether or not they are allowing joining. The coordinator will attempt to start on an unused PAN ID and channel. After starting, the coordinator may allow other devices to join its PAN. 3.1.2. Joining a Router When a router first comes up, it must locate and join a ZigBee PAN. To do this, it issues an 802.15.4 beacon request command on multiple channels to locate nearby PANs. Nearby routers and coordinators that have already joined a PAN respond to the beacon request frame with a small beacon transmission, indicating which channel and PAN ID they are operating on. The router listens on each channel for these beacon frames. If a valid PAN is found from one of the received beacons, the router issues a join request to the device that sent the beacon. If joining succeeds, the router will then receive a join confirmation from the device, indicating the join was successful. © 2007 Digi International, Inc. 16 XBee Series 2/XBee Series 2 PRO ZigBee OEM RF Module v1.x2x Once the router joins the PAN, it can communicate with other devices on the PAN and allow new devices to join to it. 3.1.3. Joining an End Device When an end device first comes up, it must also locate and join a PAN. End devices follow the same process as a router to join a PAN. Once the end device has successfully joined a PAN, it can communicate with other devices on the PAN. However, since end devices cannot route data, they must always communicate directly with their parent and allow the parent to route data in its behalf. Figure 3‐02. Demonstration of Beacon Request and Beacon transmissions that take place during joining. © 2007 Digi International, Inc. 17 XBee Series 2/XBee Series 2 PRO ZigBee OEM RF Module v1.x2x 3.2. ZigBee Network Communications Zigbee supports device addressing and application layer addressing. Device addressing specifies the destination address of the device a packet is destined to. Application layer addressing indicates a particular application recipient, known as a Zigbee endpoint, along with a message type field called a Cluster ID. 3.2.1. ZigBee Device Addressing The 802.15.4 protocol upon which the ZigBee protocol is built specifies two address types: • 16-bit network addresses • 64-bit Addresses 16-bit Network Addresses A 16-bit network address is assigned to a node when the node joins a network. The network address is unique to each node in the network. However, network addresses are not static - it can change. The following two conditions will cause a node to receive a new network address: 1. If an end device cannot communicate with its parent it may need to leave the network and rejoin to find a new parent. 2. If the device type changes from router to end device, or vice-versa, the device will leave the network and rejoin as the new device type. ZigBee requires that data be sent to the 16-bit network address of the destination device. This requires that the 16-bit address be discovered before transmitting data. See 3.2.3 Network Address Discovery for more information. 64-bit Addresses Each node contains a unique 64-bit address. The 64-bit address uniquely identifies a node and is permanent. 3.2.2. ZigBee Application-layer Addressing The ZigBee application layers define endpoints and cluster identifiers (cluster IDs) that are used to address individual services or applications on a device. An endpoint is a distinct task or application that runs on a ZigBee device, similar to a TCP port. Each ZigBee device may support one or more endpoints. Cluster IDs define a particular function or action on a device. Cluster IDs in the ZigBee home controls lighting profile, for example, would include actions such as “TurnLightOn”, “TurnLightOff”, “DimLight”, etc. Suppose a single radio controls a light dimmer and one or more light switches. The dimmer and switches could be assigned to different endpoint values. To send a message to the dimmer, a remote radio would transmit a message to the dimmer endpoint on the radio. In this example, the radio might support cluster IDs to “TurnLightOn”, “TurnLightOff”, or “DimLight”. Thus, for radio A to turn off a light on radio B, radio A would send a transmission to the light switch endpoint on radio B, using cluster ID “TurnLightOff”. This is shown in the figure below. © 2007 Digi International, Inc. 18 XBee Series 2/XBee Series 2 PRO ZigBee OEM RF Module v1.x2x Figure 3‐03. ZigBee Layer‐Addressing Example ZigBee Device B ZigBee Device A Endpoint 1 Endpoint 40 Endpoint 2 Endpoint 41 (radio B) Endpoint 3 (radio A) Endpoint 42 Cluster ID = TurnLightOff 3.2.3. Data Transmission and Routing All data packets are addressed using both device and application layer addressing fields. Data can be sent as a broadcast, multicast, or unicast transmission. Broadcast Transmissions Broadcast transmissions within the ZigBee protocol are intended to be propagated throughout the entire network such that all nodes receive the transmission. To accomplish this, all devices that receive a broadcast transmission will retransmit the packet 3 times. Figure 3‐04. Broadcast Data Transmission L eg en d C = C o o rd in ato r R = R o u ter E = E n d D evice Each node that transmits the broadcast will also create an entry in a local broadcast transmission table. This entry is used to keep track of each received broadcast packet to ensure the packets are © 2007 Digi International, Inc. 19 XBee Series 2/XBee Series 2 PRO ZigBee OEM RF Module v1.x2x not endlessly transmitted. Each entry persists for 8 seconds. The broadcast transmission table holds 8 entries. For each broadcast transmission, the ZigBee stack must reserve buffer space for a copy of the data packet. This copy is used to retransmit the packet as needed.Large broadcast packets will require more buffer space. Since broadcast transmissions are retransmitted by each device in the network, broadcast messages should be used sparingly. Multicast Transmissions Multicast transmissions operate similar to broadcast transmissions. Data packets are broadcast throughout the network in a similar fashion. However, only devices that are part of the multicast group will receive the data packets. Unicast Transmissions Unicast ZigBee transmissions are always addressed to the 16-bit address of the destination device. However, only the 64-bit address of a device is permanent; the 16-bit address can change. Therefore, ZigBee devices may employ network address discovery to identify the current 16-bit address that corresponds to a known 64-bit address, and route discovery to establish a route. Network Address Discovery Data transmissions are always sent to the 16-bit network address of the destination device. However, since the 64-bit address is unique to each device and is generally known, ZigBee devices must discover the network address that was assigned to a particular device when it joined the PAN before they can transmit data. To do this, the device initiating a transmission sends a broadcast network address discovery transmission throughout the network. This packet contains the 64-bit address of the device the initiator needs to send data to. Devices that receive this broadcast transmission check to see if their 64-bit address matches the 64-bit address contained in the broadcast transmission. If the addresses match, the device sends a response packet back to the initiator, providing the network address of the device with the matching 64-bit address. When this response is received, the initiator can then transmit data. Route Discovery ZigBee employs mesh routing to establish a route between the source device and the destination. Mesh routing allows data packets to traverse multiple nodes (hops) in a network to route data from a source to a destination. Routers and coordinators can participate in establishing routes between source and destination devices using a process called route discovery. The Route discovery process is based on the AODV (Ad-hoc On-demand Distance Vector routing) protocol. © 2007 Digi International, Inc. 20 XBee Series 2/XBee Series 2 PRO ZigBee OEM RF Module v1.x2x Figure 3‐05. Sample Transmission Through a Mesh Networkʺ AODV (Ad-hoc On-demand Distance Vector) Routing Algorithm Routing under the AODV protocol is accomplished using tables in each node that store the next hop (intermediary node between source and destination nodes) for a destination node. If a next hop is not known, route discovery must take place in order to find a path. Since only a limited number of routes can be stored on a Router, route discovery will take place more often on a large network with communication between many different nodes. Table 3‐01. Node R3 R5 Destination Address Next Hop Address Router 6 Coordinator Router 6 Router 5 Router 6 Router 6 When a source node must discover a route to a destination node, it sends a broadcast route request command. The route request command contains the source network address, the destination network address and a path cost field (a metric for measuring route quality). As the route request command is propagated through the network (refer to the Broadcast Transmission), each node that re-broadcasts the message updates the path cost field and creates a temporary entry in its route discovery table. © 2007 Digi International, Inc. 21 XBee Series 2/XBee Series 2 PRO ZigBee OEM RF Module v1.x2x Figure 3‐06. Sample Route Request (Broadcast) Transmission Where R3 is Trying to Discover a Route to R6t R3 R4 R1 R6 R2 R5 When the destination node receives a route request, it compares the ‘path cost’ field against previously received route request commands. If the path cost stored in the route request is better than any previously received, the destination node will transmit a route reply packet to the node that originated the route request. Intermediate nodes receive and forward the route reply packet to the source node (the node that originated route request). Figure 3‐07. Route Reply Sample Route Reply (Unicast) Where R6 Sends a Route Reply to R3. R4 R3 R1 R2 R6 R5 Legend First Route Reply Second Route Reply Note: R6 could send multiple replies if it identifies a better route. Retries and Acknowledgments ZigBee includes acknowledgment packets at both the Mac and Application Support (APS) layers. When data is transmitted to remote device, it may traverse multiple hops to reach the destination. As data is transmitted from one node to its neighbor, an acknowledgment packet (Ack) is transmitted in the opposite direction to indicate that the transmission was successfully received. If the Ack is not received, the transmitting device will retransmit the data, up to 4 times. This Ack is called the Mac layer acknowledgment. In addition, the device that originated the transmission expects to receive an acknowledgment packet (Ack) from the destination device. This Ack will traverse the same path that the data traversed, but in the opposite direction. If the originator fails to receive this Ack, it will retransmit © 2007 Digi International, Inc. 22 XBee Series 2/XBee Series 2 PRO ZigBee OEM RF Module v1.x2x the data, up to 2 times until an Ack is received. This Ack is called the ZigBee APS layer acknowledgment. Refer to the ZigBee specification for more details. Figure 3‐08. Unicast Data Transmission Legend Data Transmission One Network ACK: Destination to Source Mac ACK © 2007 Digi International, Inc. 23 4. XBee Series 2 Networks 4.1. XBee Series 2 Network Formation To create a ZigBee network, a coordinator must be started on a channel and PAN ID. Once the coordinator has started, routers and end device can join the network. Routers and coordinator devices can support up to 8 end device children each. Network formation is governed by the SC (Scan Channels), ID (PAN ID), SD (Scan Duration), and NJ (Node Join Time) commands. The SC and ID settings should be written using the WR command to preserve network formation or joining information." 4.1.1. Starting an XBee Series 2 Coordinator In order to form a network, a coordinator must select an unused operating channel and PAN ID on behalf of its network. To do this, the coordinator first performs an energy scan on all channels specified by its SC (Scan Channels) parameter. The scan time on each channel is determined by the SD (Scan Duration) parameter. Once the energy scan is completed, the coordinator sends a beacon request on each of the SC channels and listens for any beacons. The information from the energy scan and the beacon scan (active scan) is used to select an unused channel and PAN ID. If the ID (PAN ID) parameter is set to 0xFFFF, the coordinator will select a random PAN ID. Otherwise, the coordinator will start on the PAN ID specified by its ID parameter. After the coordinator has started, it will allow nodes to join to it for a time based on its NJ (Node Join Time) parameter. If the Associated LED function is enabled (D5 (DIO5 Configuration) command), the Associate pin (pin 15) will toggle its output state 1x per second after the coordinator started. At this point, the operating channel and PAN ID can be read using the CH (Operating Channel) and ID (PAN ID) commands. The 16-bit address of the coordinator is always 0. If API is enabled (AP parameter > 0): The API modem status “coordinator Started” frame is sent out the UART. The AI (Association Indication) command can be used at any point during the coordinator startup routine to determine the status of the startup operation. 4.1.2. Joining an XBee Series 2 Router to an existing PAN Before a router can participate in a ZigBee network, the router must locate a coordinator or another router that has already joined a PAN, and attempt to join to it. To do this, it sends a beacon request frame on each of the SC channels and listens for beacon frames. The scan duration on each channel is determined by the SD parameter. The joining router will evaluate the received beacons to find a coordinator or router that is allowing joins on a valid PAN ID, and attempt to join to that device. If ID = 0xFFFF, the router will attempt to join to a device on any PAN ID. Otherwise, the router will only attempt joining with a device that operates on the PAN ID specified by the ID parameter. If a valid router/ coordinator is found, the router will attempt to join to that node. If the join succeeds, the Router has successfully started. After the Router has started, it will allow nodes to join to it for a time based on the NJ (Node Join Time) parameter. If the Associated LED function is enabled(D5 (DIO5 Configuration) command) the Associate pin (pin 15) will toggle its output state 2x per second after the router has joined. At this point, the operating channel and PAN ID can be read using the CH (Operating Channel) and ID (PAN ID) commands. The 16-bit network address of the router can be read using the MY (16-bit Source Address) command. If API is enabled (AP parameter > 0): The API modem status “Joined” is sent out the UART. If the JN command is enabled, the router will send a node identification packet to the coordinator. The AI (Association Indication) command can be used at any point during the router join routine to know the status of the startup operation. 4.1.3. Joining an XBee Series 2 End Device to an Existing PAN Joining an end device to a PAN is similar to joining a router. Once the end device joins a PAN, however, the end device cannot allow other devices to join to it. If the Associate LED function is enabled (D5 (DIO5 Configuration) command), the Associate pin (pin 15) will toggle its output © 2007 Digi International, Inc. 24 XBee Series 2/XBee Series 2 PRO ZigBee OEM RF Modules v1.x2x state 2x per second after the end device has joined. At this point, the operating channel and PAN ID can be read using the CH (Operating Channel) and ID (PAN ID) commands. The 16-bit network address of the end device can be read using the MY (16-bit Source Address) command. If API is enabled (AP parameter > 0), the API modem status “Joined” is sent out the UART. If the JN command is enabled, the router will send a node identification packet to the coordinator. The AI (Association Indication) command can be used at any point during the router join routine to know the status of the startup operation. 4.1.4. Network Reset Once a coordinator has started, or a router or end device has joined the network, the device will continue operating on that channel and PAN ID unless one of the following occurs: 1. The ID parameter changes. 2. The SC parameter changes, such that the current operating channel is not included in the new SC parameter 3. The NR command is issued with either 0 or 1 as a parameter If any of the above occurs on a coordinator, the coordinator will attempt to restart on a channel and PAN ID based on the new saved ID and SC commands. On a router or end device, the above conditions will cause the device to leave the network (if previously joined) and attempt to join a new PAN using the saved ID and SC parameters. © 2007 Digi International, Inc. 25 XBee Series 2/XBee Series 2 PRO ZigBee OEM RF Modules v1.x2x 4.2. XBee Series 2 Addressing XBee modules support both ZigBee device addressing and application-layer addressing. Device addressing provides a simple means of sending data from one device to another by hiding the application layer addressing information (ZigBee endpoints and cluster IDs).If a device will support multiple endpoints or cluster IDs, application addressing can be used to include endpoint and cluster ID information in the transmission. Device addressing supports transmissions to: • a destination 64-bit address • a destination NI-string • the ZigBee PAN coordinator • all devices on the PAN (broadcast) • all devices on a multicast group. Application-layer addressing supports transmissions to: • all of the above device addressing destinations • specific endpoints on a destination device • specific cluster IDs on a destination device. 4.2.1. Device Addressing All XBee Series 2 modules can be identified by their unique 64-bit addresses or a user-configurable ASCII string identifier The 64-bit address of a module can be read using the SH and SL commands. The ASCII string identifier is configured using the NI command. To transmit using device addressing, only the destination address must be configured. The destination address can be specified using either the destination device’s 64-bit address or its NI-string. The XBee modules also support coordinator and broadcast addressing modes. Device addressing in the AT firmware is configured using the DL, DH, or DN commands. In the API firmware, the ZigBee Transmit Request API frame (0x10) can be used to specify destination addresses. 64-Bit Addressing (Transparent) To address a node by its 64-bit address, the destination address must be set to match the 64-bit address of the remote. In the AT firmware, the DH and DL commands set the destination 64-bit address. In the API firmware, the destination 64-bit address is set in the ZigBee Transmit Request frame. To send a packet to an RF module using its 64-bit Address (Transparent Mode) Set the DH (Destination Address High) and DL (Destination Address Low) parameters of the source node to match the 64-bit Address (SH (Serial Number High) and SL (Serial Number Low) parameters) of the destination node Since the ZigBee protocol relies on the 16-bit network address for routing, the 64-bit address must be converted into a 16-bit network address prior to transmitting data. If a module does not know the 16-bit network address for a given 64-bit address, it will transmit a broadcast network address Discovery command. The module with a matching 64-bit address will transmit its 16-bit network address back. Once the network address is discovered, the data will be transmitted. The modules maintain a table that can store up to seven 64-bit addresses and their corresponding 16-bit network addresses. © 2007 Digi International, Inc. 26 XBee Series 2/XBee Series 2 PRO ZigBee OEM RF Modules v1.x2x 64-bit Addressing (API) To send a packet to an RF module using its 64-bit Address (API Mode) Use the ZigBee Transmit Request API frame to set 64-bit destination address of the source node to match the 64-bit Address (SH (Serial Number High) and SL (Serial Number Low) parameters) of the destination node. If the 16-bit address of the destination node is not known, set 16-bit destination network address to 0xFFFE (refer to the ‘API Addressing section below). To send an API transmission to a Coordinator using its 16-bit network address:) Set the 64-bit Destination Address field to all 0's. API Mode provides the ability to store and maintain 16-bit network address tables on an external processor. The 16-bit network address information is provided to the application through the following: • The ZigBee Transmit Status Frame (contains the current 16-bit network address of the remote) • The ND and DN commands (return 64-bit and 16-bit network addresses of remote nodes) With this information, a table can be built in an application that maps a 64-bit Address to the corresponding 16-bit network address. The ZigBee Transmit Request API frame specifies the 64-bit Address and the network address (if known) that the packet should be sent to. By supplying both addresses, the module will forego network address Discovery and immediately attempt to route the data packet to the remote. If the network address of a particular remote changes, network address and route discovery will take place to establish a new route to the correct node. Upon successful packet delivery, the TX Status Frame will indicate the correct network address of the remote. Table 4‐02. Sample table mapping 64‐bit Addresses to 16‐bit Network Addresses Index 64-bit Address 16-bit Network Address 0013 4000 4000 0001 1234 0013 4000 4000 0002 5678 0013 4000 4000 01A0 A479 0013 4000 4000 0220 1F70 NI-String Addressing The NI string can alternatively be used to address a remote module. To send a packet to an RF module using its NI-string (Transparent Mode) Issue the DN (Destination Node) command using the NI (Node Identifier)-string of the destination node as the parameter. To send a packet to an RF module using its NI-string (API Mode) Issue the DN command as stated above using the AT Command API frame. When the DN command is issued, a broadcast transmission is sent across the network to discover the module that has a matching NI (Node Identifier) parameter. If a module is discovered with a matching NI-string, the DH and DL parameters will be configured to address the destination node and the command will return both the 64-bit Address and the 16-bit network address of the discovered node. Data can be transmitted after the DN (Destination Node) command finishes. the AO command. See “API Frames” section for details. Coordinator Addressing A Coordinator can be addressed using its 64-bit address or NI string as described in the “NI-String Addressing” section. Alternatively, since the ZigBee Coordinator has a network address of “0”, it can be addressed by its 16-bit network address. © 2007 Digi International, Inc. 27 XBee Series 2/XBee Series 2 PRO ZigBee OEM RF Modules v1.x2x To send a transmission to a Coordinator using its 16-bit network address: Set the Destination Address of the transmitting module as shown below: AT Firmware DL (Destination Low Address) = 0 DH (Destination High Address) = 0 API Firmware Set the 64-bit destination address field in the API transmit frame to 0x0000000000000000. Broadcast Addressing Broadcast transmissions are sent using a 64-bit address of 0x0000FFFF. Any RF module in the PAN will accept a packet that contains a broadcast address. When configured to operate in Broadcast Mode, receiving modules do not send ACKs (Acknowledgements). To send a broadcast packet to all modules Set the Destination Addresses of the transmitting module as shown below: AT Firmware DL (Destination Low Address) = 0x0000FFFF DH (Destination High Address) = 0x00000000 API Firmware Set the 64-bit destination address field in the API transmit frame to 0x000000000000FFFF. NOTE: When programming the module, parameters are entered in hexadecimal notation (without the “0x” prefix). Leading zeros may be omitted. Refer to the “Broadcast Transmissions” for more information. 4.2.2. Application-layer Addressing Application-layer addressing allows the application to specify endpoint and cluster ID values for each transmission. Addressing multiple endpoints and cluster IDs can be accomplished by explicitly setting these values as needed. In AT firmware, application-layer addressing must be enabled using the ZA command. When application-layer addressing is enabled, the DE and SE commands specify the source and destination endpoints, and the CI command sets the cluster ID that will be used in the transmission. In API firmware, the Explicit Addressing ZigBee Command frame (0x11) can be used to configure the endpoint and cluster ID addressing parameters as needed. The destination device can indicate application-layer addressing information depending on the AO parameter. Some endpoint values are reserved for use by the XBee Series 2 modules and should not be used. Please refer to the following tables for these values: Table 4‐03. XBee Series 2 Endpoint allocation Endpoint Description ZigBee Device Objects endpoint. Reserved for ZigBee stack. 0x01 - 0xDB (219) Available endpoints 0xDC (220) - 0xEE (238) Reserved for Digi Use 0xE6 (230) Command Endpoint 0xE8 (232) Data Endpoint 0xEF (239) - 0xF0 (240) Reserved for Ember Use 4.2.3. XBee Series 2 Binding Table The XBee Series 2 modules maintain a binding table that contains addressing information for all non-broadcast RF transmissions and receptions. The binding table contains a destination 64-bit address, a type field, and endpoints for each transmission. Binding table entries can be accessed © 2007 Digi International, Inc. 28 XBee Series 2/XBee Series 2 PRO ZigBee OEM RF Modules v1.x2x by setting the BI command to a valid index in AT firmware, or by using the Binding Table API Command frame in the API firmware. The binding table entries are organized as follows. Table 4‐04. Binding Table Index Name Access Coordinator Binding Read-Only Tx-Aggregation Binding Read-Only Tx-Explicit Binding Read-Write 3-4 Reserved Read-Only 5-6 Command Binding Read-Only 7-10 Received Data Bindings Read-Only 11-12 User Bindings. Read-Write Coordinator Binding The coordinator binding contains the 64-bit address of the coordinator. This table entry is populated when the device joins the network. Tx-Aggregation Binding This binding table entry contains the 64-bit address of the aggregate (sink) node if one exists. Data can be sent to the aggregate node by addressing this index in the binding table. Tx-Explicit Binding The Tx-Explicit binding table entry contains the destination address and endpoint information from the last explicit transmission that was issued. This entry is modified whenever explicit addressing is used in either the AT or API firmware as described in the "XBee Series 2 Addressing" section. Command Binding If a remote command request is received, the command binding entry stores information from the device that initiated the command. For example, if the ND or DN command is issued, this binding table entry would contain the source address of the device that sent the ND command. Received Data Bindings The received data bindings contain addressing information for the last three received data packets. The fourth entry is marked invalid. When a data packet is received, the address and endpoint information is stored into the invalid entry. Then, the oldest entry is made invalid. Thus, once an entry is created in the Received Data binding indexes, it will remain valid until three more RF data packets are received. Figure 4‐09. Demonstration of how entries in the received data bindings are replaced when an RF data packet is received. Oldest entry (3rd) is marked Invalid 3rd 2nd 1st 3rd INV INV 2nd 2nd 3rd 1st 1st 2nd 1st entry becomes second newest entry DATA 1st Newest or 1st INV 3 Data entries + 1 invalid entry 2nd newest entry becomes oldest data entry DATA Data is inserted into Invalid entry © 2007 Digi International, Inc. 29 XBee Series 2/XBee Series 2 PRO ZigBee OEM RF Modules v1.x2x User Bindings These entries can be created and maintained by the application if needed. The following commands can be used to modify the user bindings. See the command descriptions for formatting details. Table 4‐05. Command Name B+ Add Binding Description Creates a binding table entry at a specified User Binding index. B- Remove Binding Removes a binding from a specified User Binding index. BV View Binding Views one or more bindings in the binding table. WB Write Binding Writes the binding table to non-volatile memory. 4.2.4. XBee Series 2 Endpoint Table The XBee Series 2 modules maintain a table of supported endpoints. If an endpoint will be used as the source endpoint in a data transmission, the endpoint must first be defined in the endpoint table. The XBee Series 2 endpoint table operates similar to the binding table. Entries may be added, removed, or viewed using the E+, E-, and EV commands respectively. Some table entries are reserved for special purposes Table 4‐06. Endpoint Table Index Name Access Command Endpoint Read-Only Data Endpoint Read-Only Tx-Explicit Endpoint Read-Write 3- 4 User Endpoints Read-Write Command Endpoint The command endpoint is used to send or reply to various commands. This endpoint must exist in the application. Data Endpoint This endpoint is used to send serial data to other XBee Series 2 modules. It must always exist in the application. Tx-Explicit Endpoint This entry is used as needed to define the source endpoint that must be defined for a data transmission. If a transmit request is made, and the specified source endpoint does not exist, it will be created temporarily at this endpoint table index. User Endpoints User endpoints are controlled entirely by the application. These endpoints may be added, removed, or viewed in the API firmware using the following commands. See the command descriptions for command formatting details. At present, changes to the endpoint table are saved to non-volatile memory when WR is issued. Table 4‐07. ZigBee Data Transmissions Addressing Fields Command Name Description E+ Add Endpoint Creates an endpoint entry at a specified user endpoint index. E- Remove Endpoint Removes an endpoint entry from a specified user endpoint index. EV View Endpoint Views one or more endpoints in the endpoint table. © 2007 Digi International, Inc. 30 XBee Series 2/XBee Series 2 PRO ZigBee OEM RF Modules v1.x2x 4.3. Sleep Mode Operation XBee Series 2 modules support sleep mode operation in the Router / End Device firmware. Sleep modes allow a ZigBee end device to enter a low power mode when idle and wake as needed to transmit or receive data. See Chapter 2 "RF Module Operation" for more information about different sleep modes. 4.3.1. End Device Operation ZigBee end devices rely on a parent (router or coordinator) to remain awake and receive any data packets destined for the end device. When the end device wakes from sleep, it sends a transmission (poll request) to its parent asking if the parent has received any RF data destined for the end device. The parent, upon receipt of the poll request, will send an RF response and the buffered data (if present). If the end device is awake with the ST timer running (SM=4), or if Sleep_RQ is de-asserted (SM=1), the end device will send poll requests every 100ms to ensure it receives any new RF data from its parent. 4.3.2. Parent Operation When an end device joins a ZigBee PAN, it becomes a child of the (coordinator or router) device it joined to, and the device that allowed the join becomes the end device's parent. Thereafter, the parent will manage RF data packets for the end device. If the parent receives an RF packet destined for the end device, it will store the data packet until one of the following occurs: • The parent runs out of storage space and cannot store a new packet. • A packet has been stored for a period of time. • The destination end device child sends a poll request transmission to request the data packet. When the parent stores a packet destined for an end device child, it stores the packet for a maximum time set by SP. The actual storage time is computed as (SP * 2.5), not exceeding 30 seconds. If end devices implement cyclic sleep, SP should be set the same on a parent as it is on their sleeping end device children. In the case of pin sleep, where RF data could be received, the end device should wake within SP time to ensure data is not lost. 4.4. I/O Line Configuration The XBee Series 2 modules support both analog input and digital IO line modes on several configurable pins. Configuring A/D and Digital Lines The following table lists the pin functions supported on the modules Table 4‐08. Module Pin Names Module Pin Numbers Configuration Command CD/DIO12 P2 PWM0/RSSI/DIO10 P0 PWM/DIO11 P1 SLEEP_RQ/DIO8 IO Configuration not supported DIO4 11 D4 CTS/DIO7 12 D7 ON_SLEEP/DIO9 13 IO Configuration not supported ASSOC/DIO5 15 D5 © 2007 Digi International, Inc. 31 XBee Series 2/XBee Series 2 PRO ZigBee OEM RF Modules v1.x2x Table 4‐08. Module Pin Names Module Pin Numbers Configuration Command RTS/DIO6 16 D6 AD3/DIO3 17 D3 AD2/DIO2 18 D2 AD1/DIO1 19 DI AD0/DIO0 20 D0 Setting the configuration command that corresponds to a particular pin will configure the pin. Parameters for the pin configuration commands typically include the following: Table 4‐09. Pin Command Parameter Description Unmonitored digital input Reserved for pin-specific alternate functionalities Analog input, single ended (A/D pins only) Digital input, monitored Digital output, default low Digital output, default high 6-9 Alternate functionalities, where applicable See the command table for more information. Pullup resistors for each digital input can be enabled using the PR command. Sampling A/D and Digital Input Lines The IS command can be used to sample the current value of all enabled A/D and digital input lines. . Bytes Name Description Sample sets in packet Number of sample sets in the packet Digital Channel Mask Each bit in the digital channel mask corresponds to one digital IO line. The bits, from LSB to MSB, correspond to DOI0-DOI5 on the module. For example a digital channel mask of 0x002F means DIO0,1,2,3, and 5 are enabled as digital input lines. Var Analog Channel Mask Sampled Data Set © 2007 Digi International, Inc. Each bit in the analog channel mask corresponds to one analog channel. The bits from LSB to MSB correspond to AIN0-AIN7 on the module. For example, if the analog channel mask is 0x06, AINI and AIN3 are enabled as analog input lines. A sample set consisting of 1 sample for each enabled ADC and/or DIO channel. If any digital input lines are enabled, the first two bytes indicate the state of all enabled digital input lines. Each bit in these two bytes corresponds to one digital IO line, similar to the way each bit in the diglossia channel mask corresponds. Note: only the digital input line that are enabled in the detail channel mask have valid readings. Channels that are not enabled as digital input lines will return a 0 in the sampled data set. If no pins are configured as digital inputs, these 2 bytes will be omitted. Following the digital input data, if any, each enabled analog channel will return 2 bytes (10bits). The analog data is scaled such that 0 represents 0V, and 0x3FF=1.2V. The analog input lines cannot measure more than 1.2V. Information for each enabled analog channel is returned in order, starting with AIN0 and finishing with AIN4. Only enabled analog input channels will return data. 32 XBee Series 2/XBee Series 2 PRO ZigBee OEM RF Modules v1.x2x The AT firmware returns a carriage return delimited list containing the above-listed fields. The API firmware returns an AT command response API frame with the IO data included in the command data portion of the packet. Example Sample AT Response 0x01\r [1 sample set] 0x0C0C\r [Digital Inputs: DIO 2, 3, 10, 11 low] 0x03\r [Analog Inputs: A/D 0, 1] 0x0408\r [Digital input states: DIO 3, 10 high, DIO 2, 11 low] 0x03D0\r [Analog input ADIO 0= 0x3D0] 0x0124\r [Analog input ADIO 1=0x120] To convert the A/D reading to mV, do the following: AD(mV)= (ADIO reading/0x3FF)*1200mV The reading in the sample frame represent voltage inputs of 1144.9 and 342.5mV for ADIO0 and ADIO1 respectively. © 2007 Digi International, Inc. 33 5. Advanced Features The XBee Series 2 modules come with several features to assist with discovering, configuring, and testing ZigBee networks. These features include • Device Discovery • Remote Configuration • Loopback Testing • Join Indicators • Manual Device Identification • Battery Life Monitoring. 5.1. Device Discovery The Node Discovery command can be used to discover all modules that have joined a ZigBee PAN. Issuing ND sends a broadcast node discovery command throughout the PAN. ll devices that receive the command will send a response that includes the device's 64-bit address, 16-bit address, and NI-string (see NI command). This command is useful for generating a list of all module addresses in a PAN. 5.2. Remote Configuration The API firmware has provisions to configure the command registers of remote devices using the Remote Command Request API frame (see Chapter 7 - API Operation). Commands can be sent to a remote module to read or set different command parameters. 5.3. Loopback Testing Range and link quality can be tested easily using a software loopback data mode. To send a message to a remote device and have the data be returned to the sender, the data should be addressed to the loopback cluster ID (0x12) on the data endpoint (0xE6) of the remote device. 5.3.1. AT Firmware Set the ZA command to 1 and set the CI command value to 0x12. The SE and DE commands should be set to 0xE8 (default value). The DH and DL commands should be set to the 64-bit address of the remote. After exiting command mode, serial data should be transmitted to the remote device and returned to the sender. 5.3.2. API Firmware Send an Explicit Addressing ZigBee Command frame using 0x12 as the cluster ID and 0xE8 as the source and destination endpoint. Data packets received by the remote should be echoed back to the sender. 5.4. Join Indicators The JN command can be used to send a message to the coordinator when a router or end device joins the network. If JN is set to enable join notifications, an ND response packet will be sent to the coordinator when the device joins the PAN. (Only API coordinators will display the join notification.) The format of this packet on the coordinator depends on the AO setting. 5.5. Manual Device Identification The D0 command can be set to send a node identification packet to the coordinator when a low-tohigh edge is detected on module pin 20. The node identification packet includes the XBee module's © 2007 Digi International, Inc. 34 XBee Series 2/XBee Series 2 PRO ZigBee OEM RF Modules v1.x2x 64-bit and 16-bit addresses and its NI-string. (Only API coordinators will display the node identification packet.) Connecting a push-button to module pin 20 provides a simple mechanism for manually identifying a module to the coordinator during deployment. 5.6. Battery Life Monitoring The %V command can be used to determine the supply voltage on a device. This command can also be sent (in API firmware) to remote devices in the PAN to monitor their supply voltage level. © 2007 Digi International, Inc. 35 6. XBee Series 2 Command Reference Tables Special Table 6‐01. Special Commands AT Name and Description Command Node Type1 Parameter Range Default WR Write. Write parameter values to non-volatile memory so that parameter modifications persist through subsequent resets. Note: Once WR is issued, no additional characters should be sent to the module until after the "OK\r" response is received. CRE -- -- WB Write Binding Table: Writes the current binding table to non-volative memory. CRE -- -- RE Restore Defaults. Restore module parameters to factory defaults. RE command does not reset the ID parameter. CRE -- -- FR Software Reset. Reset module. Responds immediately with an “OK” then performs a reset ~2 seconds later. Use of the FR command will cause a network layer restart on the CRE node if SC or ID were modified since the last reset. -- -- NR Network Reset. Reset network layer parameters on one or more modules within a PAN. Responds immediately with an “OK” then causes a network restart. All network configuration and routing information is consequently lost. If NR = 0: Resets network layer parameters on the node issuing the command. If NR = 1: Sends broadcast transmission to reset network layer parameters on all nodes in the PAN. 0-1 -- CRE Node types that support the command: C = Coordinator, R = Router, E = End Device Addressing Table 6‐02. Addressing Commands) AT Name and Description Command Node Type1 Parameter Range Default DH2 Destination Address High. Set/Get the upper 32 bits of the 64-bit destination address. When combined with DL, it defines the destination address used for transmission. CRE 0x000000000000FFFF is the broadcast address for the PAN. DH is not supported in API Mode. 0x0000000000000000 is the Coordinator’s 16-bit network address. 0 - 0xFFFFFFFF Destination Address Low. Set/Get the lower 32 bits of the 64-bit destination address. When combined with DH, DL defines the destination address used for transmission. CRE 0x000000000000FFFF is the broadcast address for the PAN. DL is not supported in API Mode. 0x0000000000000000 is the Coordinator’s 16-bit network address. 0 - 0xFFFFFFFF 0xFFFF(Coordinator) 0 (Router/End Device) MY 16-bit Network Address. Get the 16-bit network address of the module. 0 - 0xFFFE [read-only] 0xFFFE MP 16-bit Parent Network Address. Get the 16-bit parent network address of the module. E 0 - 0xFFFE [read-only] 0xFFFE SH Serial Number High. Read high 32 bits of the RF module's unique IEEE 64-bit address. 64-bit source address is always enabled. CRE 0 - 0xFFFFFFFF [read-only] factory-set SL Serial Number Low. Read low 32 bits of the RF module's unique IEEE 64-bit address. CRE 64-bit source address is always enabled. 0 - 0xFFFFFFFF [read-only] factory-set NI Node Identifier. Stores a string identifier. The register only accepts printable ASCII data. In AT Command Mode, a string can not start with a space. A carriage return ends the command. Command will automatically end when maximum bytes for the string CRE have been entered. This string is returned as part of the ND (Node Discover) command. This identifier is also used with the DN (Destination Node) command. 20-Byte printable ASCII string -- DD Device Type Identifier. Stores a device type value. This value can be used to differentiate multiple XBee-based products. CRE 0 - 0xFFFF [read-only] ZA2 ZigBee Application Layer Addressing. Set/read the Zigbee application layer addressing enabled attribute. If enabled, data packets will use the SE, DE, and CI commands to address Zigbee application layer source and destination endpoints, and the cluster ID fields in all data transmissions. ZA is only supported in the AT firmware. CRE 0-1 Source Endpoint. Set/read the ZigBee application layer source endpoint value. If ZigBee application layer addressing is enabled (ZA command), this value will be used as the source endpoint for all data transmissions. SE is only supported in AT firmware.The default value 0xE8 (Data endpoint) is the Digi data endpoint CRE 1 - 0xEF 0xE8 DE2 Destination Endpoint. Set/read Zigbee application layer destination ID value. If ZigBee application layer addressing is enabled (ZA command), this value will be used as the destination endpoint all data transmissions. DE is only supported in AT firmware.The default value (0xE8) is the Digi data endpoint. CRE 0 - 0xEF 0xE8 DL SE © 2007 Digi International, Inc. CRE 36 XBee Series 2/XBee Series 2 PRO ZigBee OEM RF Modules v1.x2x Table 6‐02. Addressing Commands) AT Name and Description Command Node Type1 Parameter Range Default CI2 Cluster Identifier. Set/read Zigbee application layer cluster ID value. If ZigBee application layer addressing is enabled (ZA command), this value will be used as the cluster ID for all data transmissions. CI is only supported in AT firmware.The default value0x11 (Transparent data cluster ID). CRE 0 - 0xFF 0x11 BI2 Binding Table Index. Set/read the binding table index value. If this value is set to a valid binding table index, the addressing information at that index in the binding table will be used for all data transmissions. BI is only supported in AT firmware CRE 0 - 0xFF 0xFF Parameter Range Default 1. Node types that support the command: C=Coordinator, R=Router, E=End Device 2. Command supported by modules using AT Command firmware only Networking & Security Table 6‐03. Networking Commands AT Name and Description Command Node Type1 CH Operating Channel. Read the channel number used for transmitting and receiving between RF modules. Uses 802.15.4 channel numbers. A value of 0 means the device CRE has not joined a PAN and is not operating on any channel. 0, 0x0B-0x1A (XBee) ID PAN ID. Set/Get the PAN (Personal Area Network) ID. Coordinator - Set the preferred Pan ID. Set ID = 0xFFFF to auto-select. Router / End Device - Set the desired Pan ID. When the device searches for a Coordinator, it attempts to only join to a parent that has a matching Pan ID. Set ID = 0xFFFF to join a parent operating on any Pan ID. Changes to ID should be written to non-volatile memory using the WR command. CRE 0 - 0x3FFF, 0xFFFF 0x0234 (291d) BH Broadcast Hops. Set/Read the maximum number of hops for each broadcast data transmission. Setting this to 0 will use the maximum number of hops. CRE 0 - 0x0F -- NT Node Discover Timeout. Set/Read the amount of time a node will spend discovering other nodes when ND or DN is issued. CRE 0 - 0xFC [x 100 msec] 0x3C (60d) ND Node Discover. Discovers and reports all RF modules found. The following information is reported for each module discovered. MYSH SL NI (Variable length) PARENT_NETWORK ADDRESS (2 Bytes) DEVICE_TYPE (1 Byte: 0=Coord, 1=Router, 2=End Device) STATUS (1 Byte: Reserved) PROFILE_ID (2 Bytes) CRE MANUFACTURER_ID (2 Bytes) After (NT * 100) milliseconds, the command ends by returning a . ND also accepts a Node Identifier (NI) as a parameter (optional). In this case, only a module that matches the supplied identifier will respond. If ND is sent through the API, each response is returned as a separate AT_CMD_Response packet. The data consists of the above listed bytes without the carriage return delimiters. The NI string will end in a "0x00" null character. The radius of the ND command is set by the BH command. optional 20-Byte NI or MY value -- DN Destination Node. Resolves an NI (Node Identifier) string to a physical address (casesensitive). The following events occur after the destination node is discovered: 1. DL & DH are set to the extended (64-bit) address of the module with the matching NI (Node Identifier) string. 2. OK (or ERROR)\r is returned. 3. Command Mode is exited to allow immediate communication CRE 1. The 16-bit network and 64-bit extended addresses are returned in an API Command Response frame. If there is no response from a module within (NT * 100) milliseconds or a parameter is not specified (left blank), the command is terminated and an “ERROR” message is returned. In the case of an ERROR, Command Mode is not exited. The radius of the DN command is set by the BH command. up to 20-Byte printable ASCII string -- JN Join Notification. Set/read the join notification value. If enabled, the device will send a RE transmission after joining a PAN, identifying itself to the coordinator. © 2007 Digi International, Inc. 0 - Join notification disabled 1 - Send notification only to coordinator after joining 1 PAN 37 XBee Series 2/XBee Series 2 PRO ZigBee OEM RF Modules v1.x2x Table 6‐03. Networking Commands AT Name and Description Command Node Parameter Range Default SC Scan Channels. Set/Read the list of channels to scan. Coordinator - Bit field list of channels to choose from prior to starting network. Router/End Device - Bit field list of channels that will be scanned to find a Coordinator/ Router to join. CRE Changes to SC should be written using WR command. Bit (Channel): 0 (0x0B) 4 (0x0F) 8 (0x13) 12 (0x17) 1 (0x0C) 5 (0x10) 9 (0x14) 13 (0x18) 2 (0x0D) 6 (0x11) 10 (0x15) 14 (0x19) 3 (0x0E) 7 (0x12) 11 (0x16) 15 (0x1A) 1 - 0xFFFF[bitfield] 0x1FFE SD Scan Duration. Set/Read the scan duration exponent. Changes to SD should be written using WR command. Coordinator - Duration of the Active and Energy Scans (on each channel) that are used to determine an acceptable channel and Pan ID for the Coordinator to startup on. Router / End Device - Duration of Active Scan (on each channel) used to locate an available Coordinator / Router to join during Association. Scan Time is measured as:(# Channels to Scan) * (2 ^ SD) * 15.36ms - The number of CRE channels to scan is determined by the SC parameter. The XBee can scan up to 16 channels (SC = 0xFFFF). Sample Scan Duration times (13 channel scan): If SD = 0, time = 0.200 sec SD = 2, time = 0.799 sec SD = 4, time = 3.190 sec SD = 6, time = 12.780 sec 0 - 7 [exponent] NJ Node Join Time. Set/Read the time that a Coordinator/Router allows nodes to join. This value can be changed at run time without requiring a Coordinator or Router to restart. The time starts once the Coordinator or Router has started. The timer is reset on power-cycle or when NJ changes. 0 – 0x40, 0xFF [x 1 sec] 0xFF (always allows joining) AR Aggregate Routing Notification. Set/read time between consecutive aggregate route broadcast messages. If used, AR should be set on only one device to enable many-to- CR one routing to the device. Setting AR to 0 only sends one broadcast 0 - 0xFF 0xFF AI Association Indication. Read information regarding last node join request: 0x00 - Successful completion - Coordinator started or Router/End Device found and joined with a parent. 0x21 - Scan found no PANs CRE 0x22 - Scan found no valid PANs based on current SC and ID settings 0x23 - Valid Coordinator or Routers found, but they are not allowing joining (NJ expired) 0x27 - Node Joining attempt failed 0x2A - Coordinator Start attempt failed‘ 0xFF - Scanning for a Parent 0 - 0xFF [read-only] -- Type1 CR RF Interfacing Table 6‐04. RF Interfacing Commands AT Name and Description Command Node Parameter Range Type1 PL Power Level. Select/Read the power level at which the RF module transmits conducted CRE power. PM Power Mode. Set/read the power mode of the device. Enabling boost mode will improve CRE the receive sensitivity by 1dB and increase the transmit power by 2dB 0 - 4 (XBee ) 0 = -10 / 10 dBm 1 = -6 / 12 dBm 2 = -4 / 14 dBm 3 = -2 / 16 dBm 4 = 0 / 18 dBm Default 0-1, 0= -Boost mode disabled, 1= Boost mode enabled. 1 1. Node types that support the command: C = Coordinator, R = Router, E = End Device Serial Interfacing (I/O) Table 6‐05. Serial Interfacing Commands AT Name and Description Command AP2 API Enable. Enable API Mode. The AP parameter is only applicable when using modules that contain the following firmware versions:1.1xx (coordinator), 1.3xx (router/end device) © 2007 Digi International, Inc. Node Parameter Range Type1 CRE 1-2 1 = API-enabled 2 = API-enabled (w/escaped control characters) Default 38 XBee Series 2/XBee Series 2 PRO ZigBee OEM RF Modules v1.x2x Table 6‐05. Serial Interfacing Commands AT Name and Description Command Node Parameter Range Type1 Default 0 - Default receive API indicators enabled 1 - Explicit Rx data indicator API frame enabled (0x91) BD Interface Data Rate. Set/Read the serial interface data rate for communication between the module serial port and host. CRE Any value above 0x07 will be interpreted as an actual baud rate. When a value above 0x07 is sent, the closest interface data rate represented by the number is stored in the BD register. 0-7 (standard baud rates) 0 = 1200 bps 1 = 2400 2 = 4800 3 = 9600 4 = 19200 5 = 38400 6 = 57600 7 = 115200 0x80 - 0x38400 (non-standard rates) RO Packetization Timeout. Set/Read number of character times of inter-character silence required before packetization. Set (RO=0) to transmit characters as they arrive instead of CRE buffering them into one RF packet. 0 - 0xFF [x character times] D7 DIO7 Configuration. Select/Read options for the DIO7 line of the RF module. CRE 0 = Disabled 1 = CTS Flow Control 3 = Digital input 4 = Digital output, low 5 = Digital output, high 6 = RS-485 transmit enable (low enable) 7 = RS-485 transmit enable (high enable) D6 DIO6 Configuration. Configure options for the DIO6 line of the RF module. CRE 0 - Disabled 1 - RTS Flow Control CRE 0 = Disabled 1 = Associated indication LED 3 = Digital input 4 = Digital output, default low 5 = Digital output, default high AO2 D5 API Options. Configure options for API. Current options select the type of receive API frame to send out the Uart for received RF data packets. DIO5 Configuration. Configure options for the DIO5 line of the RF module. CRE 1. Node types that support the command: C = Coordinator, R = Router, E = End Device 2. Command supported by modules using API firmware only I/O Commands Table 6‐06. I/O Commands AT Name and Description Command P0 P1 PWM0 Configuration. Select/Read function for PWM0. DIO11 Configuration. Configure options for the DIO11 line of the RF module. © 2007 Digi International, Inc. Node Parameter Range Type1 CRE 0 = Disabled 1 = RSSI PWM 3 - Digital input, monitored 4 - Digital output, default low 5 - Digital output, default high CRE 0 - Unmonitored digital input 3- Digital input, monitored 4- Digital output, default low 5- Digital output, default high Default 39 XBee Series 2/XBee Series 2 PRO ZigBee OEM RF Modules v1.x2x Table 6‐06. I/O Commands AT Name and Description Command Node Parameter Range Type1 0 - Unmonitored digital input 3- Digital input, monitored 4- Digital output, default low 5- Digital output, default high Default P2 DIO12 Configuration. Configure options for the DIO12 line of the RF module. CRE RP RSSI PWM Timer. Time RSSI signal will be output after last transmission. When RP = 0xFF, output will always be on. CRE 0 - 0xFF [x 100 ms] 0x28 (40d) IS Force Sample Forces a read of all enabled digital and analog input lines. CRE -- -- CRE 0-5 0 – Disabled 1 - Node identification button enabled 2 - Analog input, single ended 3 – Digital input 4 – Digital output, low 5 – Digital output, high 1 (RE), 0 (C) CRE 0, 2-5 0 – Disabled 2 - Analog input, single ended 3 – Digital input 4 – Digital output, low 5 – Digital output, high D0 D1 D2 D3 AD0/DIO0 Configuration. Select/Read function for AD0/DIO0. AD1/DIO1 Configuration. Select/Read function for AD1/DIO1. AD2/DIO2 Configuration. Select/Read function for AD2/DIO2. AD3/DIO3 Configuration. Select/Read function for AD3/DIO3. CRE CRE D4 DIO4 Configuration. Select/Read function for DIO4. CRE PR Set/read the bit field that configures the internal pull-up resistor status for the I/O lines. "1" specifies the pull-up resistor is enabled. "0" specifies no pullup. Bits:" 0 - DIO4 (Pin 11) 1 - AD3 / DIO3 (Pin 17) 2 - AD2 / DIO2 (Pin 18) 3 - AD1 / DIO1 (Pin 19) 4 - AD0 / DIO0 (Pin 20) 5 - RTS / DIO6 (Pin 16) 6 - DTR / Sleep Request / DIO8 (Pin 9) 7 - DIN / Config (Pin 3) 8 - Associate / DIO5 (Pin 15) 9 - On/Sleep / DIO9 (Pin 13) 10 - DIO12 (Pin 4) 11 - PWM0 / RSSI / DIO10 (Pin 6) 12 - PWM1 / DIO11 (Pin 7) CRE © 2007 Digi International, Inc. 0, 2-5 0 – Disabled 2 - Analog input, single ended 3 – Digital input 4 – Digital output, low 5 – Digital output, high 0, 2-5 0 – Disabled 2 - Analog input, single ended 3 – Digital input 4 – Digital output, low 5 – Digital output, high 0, 3-5 0 – Disabled 3 – Digital input 4 – Digital output, low 5 – Digital output, high 0 - 0x1FFF 0 - 0x1FFF 40 XBee Series 2/XBee Series 2 PRO ZigBee OEM RF Modules v1.x2x Diagnostics Table 6‐07. Diagnostics Commands AT Name and Description Command Node Parameter Range Type1 Default VR Firmware Version. Read firmware version of the module. CRE 0 - 0xFFFF [read-only] Factory-set HV Hardware Version. Read hardware version of the module. CRE 0 - 0xFFFF [read-only] Factory-set %V Supply Voltage. Reads the voltage on the Vcc pin. To convert the reading to a mV reading, divide the read value by 1023 and multiply by 1200. A %V reading of 0x8FE (2302 decimal) represents 2700mV or 2.70V. CRE 1. Node types that support the command:C = Coordinator, R = Router, E = End Device AT Command Options Table 6‐08. AT Command Options Commands AT Name and Description Command Node Parameter Range Type1 Default CT2 Command Mode Timeout. Set/Read the period of inactivity (no valid commands received) after which the RF module automatically exits AT Command Mode and returns CRE to Idle Mode. 2 - 0x028F [x 100 ms] 0x64 (100d) CN2 Exit Command Mode. Explicitly exit the module from AT Command Mode. -- -- GT2 Guard Times. Set required period of silence before and after the Command Sequence Characters of the AT Command Mode Sequence (GT + CC + GT). The period of silence CRE is used to prevent inadvertent entrance into AT Command Mode. 1 - 0x0CE4 [x 1 ms] 0x3E8 (max of 3.3 decimal sec) (1000d) CC2 Command Sequence Character. Set/Read the ASCII character value to be used between Guard Times of the AT Command Mode Sequence (GT + CC + GT). The AT Command Mode Sequence enters the RF module into AT Command Mode. CC command is only applicable when using modules that contain the following “AT Command” firmware versions: 8.0xx (Coordinator), 8.2xx (Router), 8.4xx (End Device) 0 - 0xFF CRE CRE 0x2B (‘+’ ASCII) 1. Node types that support the command: C = Coordinator, R = Router, E = End Device 2. Command supported by modules using AT Command firmware only Sleep Commands Table 6‐09. Sleep Commands AT Name and Description Command Node Parameter Range Type1 Default 0-Sleep disabled 1-Pin sleep enabled 4-Cyclic sleep enabled Note: When SM=0, the device operates as a router. When SM changes to a non-zero value, the router leaves the network and rejoins as an end device. Only end devices can sleep SM Sleep Mode Sets the sleep mode on the RF module SN Number of Sleep Periods. Sets the number of sleep periods to not assert the On/Sleep pin on wakeup if no RF data is waiting for the end device. This command allows a host RE application to sleep for an extended time if no RF data is present 1 - 0xFFFF SP Sleep Period. This value determines how long the end device will sleep at a time, up to 28 seconds. (The sleep time can effectively be extended past 28 seconds using the SN command.) On the parent, this value determines how long the parent will buffer a CRE message for the sleeping end device. It should be set at least equal to the longest SP time of any child end device. 0x20 - 0xAF0 x 10ms (Quarter second resolution) 0x20 ST Time Before Sleep Sets the time before sleep timer on an end device.The timer is reset each time serial or RF data is received. Once the timer expires, an end device may enter RE low power operation. Applicable for cyclic sleep end devices only. 1 - 0xFFFE (x 1ms) 0x1388 (5 seconds) © 2007 Digi International, Inc. RE 41 7. API Operation As an alternative to Transparent Operation, API (Application Programming Interface) Operations are available. API operation requires that communication with the module be done through a structured interface (data is communicated in frames in a defined order). The API specifies how commands, command responses and module status messages are sent and received from the module using a UART Data Frame. 7.0.1. API Frame Specifications Two API modes are supported and both can be enabled using the AP (API Enable) command. Use the following AP parameter values to configure the module to operate in a particular mode: • AP = 1: API Operation • AP = 2: API Operation (with escaped characters) API Operation (AP parameter = 1) When this API mode is enabled (AP = 1), the UART data frame structure is defined as follows: Figure 7‐01. UART Data Frame Structure: Start Delimiter (Byte 1) 0x7E Length (Bytes 2-3) MSB LSB Frame Data (Bytes 4-n) Checksum (Byte n + 1) API-specific Structure 1 Byte MSB = Most Significant Byte, LSB = Least Significant Byte Any data received prior to the start delimiter is silently discarded. If the frame is not received correctly or if the checksum fails, the module will reply with a module status frame indicating the nature of the failure. API Operation - with Escape Characters (AP parameter = 2) When this API mode is enabled (AP = 2), the UART data frame structure is defined as follows: Figure 7‐02. UART Data Frame Structure ‐ with escape control characters: Start Delimiter (Byte 1) 0x7E Length (Bytes 2-3) MSB LSB Frame Data (Bytes 4-n) Checksum (Byte n + 1) API-specific Structure 1 Byte Characters Escaped If Needed MSB = Most Significant Byte, LSB = Least Significant Byte Escape characters. When sending or receiving a UART data frame, specific data values must be escaped (flagged) so they do not interfere with the data frame sequencing. To escape an interfering data byte, insert 0x7D and follow it with the byte to be escaped XOR’d with 0x20. © 2007 Digi International, Inc. 42 XBee Series 2/XBee Series 2 PRO ZigBee OEM RF Modules v1.x2x Data bytes that need to be escaped: • 0x7E – Frame Delimiter • 0x7D – Escape • 0x11 – XON • 0x13 – XOFF Example - Raw UART Data Frame (before escaping interfering bytes): 0x7E 0x00 0x02 0x23 0x11 0xCB 0x11 needs to be escaped which results in the following frame: 0x7E 0x00 0x02 0x23 0x7D 0x31 0xCB Note: In the above example, the length of the raw data (excluding the checksum) is 0x0002 and the checksum of the non-escaped data (excluding frame delimiter and length) is calculated as: 0xFF - (0x23 + 0x11) = (0xFF - 0x34) = 0xCB. Checksum To test data integrity, a checksum is calculated and verified on non-escaped data. To calculate: Not including frame delimiters and length, add all bytes keeping only the lowest 8 bits of the result and subtract the result from 0xFF. To verify: Add all bytes (include checksum, but not the delimiter and length). If the checksum is correct, the sum will equal 0xFF. 7.0.2. API Frames Frame data of the UART data frame forms an API-specific structure as follows: Figure 7‐03. UART Data Frame & API‐specific Structure: Start Delimiter (Byte 1) 0x7E Length (Bytes 2-3) MSB LSB Frame Data (Bytes 4-n) Checksum (Byte n + 1) API-specific Structure 1 Byte API Identifier Identifier-specific Data cmdID cmdData The cmdID frame (API-identifier) indicates which API messages will be contained in the cmdData frame (Identifier-specific data). Note that multi-byte values are sent big endian.The XBee Series 2 modules support the following API frames: Table 7‐010. API Frame Names and Values API Frame Names Values Modem Status 0x8A Advanced Modem Status 0x8C AT Command 0x08 AT Command - Queue Parameter Value 0x09 AT Command Response 0x88 Remote Command Request 0x17 Remote Command Response 0x97 ZigBee Transmit Request 0x10 Explicit Addressing ZigBee Command Frame 0x11 ZigBee Transmit Status 0x8B © 2007 Digi International, Inc. 43 XBee Series 2/XBee Series 2 PRO ZigBee OEM RF Modules v1.x2x Table 7‐010. API Frame Names and Values API Frame Names Values ZigBee Receive Packet (AO=0) 0x90 ZigBee Explicit Rx Indicator (AO=1) 0x91 XBee Sensor Read Indicator (AO=0) 0x94 Node Identification Indicator (AO=0) 0x95 Modem Status API Identifier Value: (0x8A) RF module status messages are sent from the module in response to specific conditions. Figure 7‐04. Modem Status Frames S ta rt D e lim ite r 0x7E L e n g th M SB LSB F ra m e D a ta C hecksum A P I-s p e c ific S tru c tu re 1 B y te A P I Id e n tifie r Id e n tifie r-s p e c ific D a ta 0x8A c m d D a ta S ta tu s (B y te 5 ) H a rd w a re re s e t W a tc h d o g tim e r re s e t A s s o c ia te d D is a s s o c ia te d S y n c h ro n iz a tio n L o s t (B e a c o n -e n a b le d o n ly) 5 = C o o rd in a to r re a lig n m e n t 6 = C o o rd in a to r s ta rte d Advanced Modem Status Frame API Identifier Value:(0x8C) Note: This API Frame may change or become obsolete in future versions. Do not use. © 2007 Digi International, Inc. 44 XBee Series 2/XBee Series 2 PRO ZigBee OEM RF Modules v1.x2x Figure 7‐05. Advanced Modem Status Frames: Do Not Use! Start delim inator 0x7E Fram e D ata Length M SB LSB C hecksum API-specific Structure 1 Byte API Identifier Identifier specific data 0x8C cm dD ata Status ID © 2007 Digi International, Inc. [Bind Table Index] + [Bind Type] Bind Type 1 – U nicast Binding Bind Type 2 – A ggregation Binding Bind Type 3 – M ulticast Binding 45 XBee Series 2/XBee Series 2 PRO ZigBee OEM RF Modules v1.x2x AT Command API Identifier Value: (0x08) Allows for module parameter registers to be queried or set. Figure 7‐6. AT Command Frames Start Delimiter Length 0x7E MSB LSB Frame Data Checksum API-specific Structure 1 Byte API Identifier Identifier-specific Data 0x08 cmdData Frame ID (Byte 5) AT Command (Bytes 6-7) Identifies the UART data frame for the host to correlate with a subsequent ACK (acknowledgement). If set to ‘0’, no response is sent. Command Name - Two ASCII characters that identify the AT Command. Figure 7‐7. Example: API frames when reading the NJ parameter value of the module. Byte 1 Bytes 2-3 0x7E Parameter Value (Byte(s) 8-n) If present, indicates the requested parameter value to set the given register. If no characters present, register is queried. 0x00 Start Delimiter Byte 4 Byte 5 Bytes 6-7 Byte 8 0x08 0x52 (R) 0x4E (N) 0x4A (J) 0x0D API Identifier Frame ID** AT Command Checksum 0x04 Length* * Length [Bytes] = API Identifier + Frame ID + AT Command ** “R” value was arbitrarily selected. Figure 7‐8. Byte 1 Example: API frames when modifying the NJ parameter value of the module. Bytes 2-3 0x7E 0x00 Start Delimiter Byte 4 0x05 Byte 5 0x08 Length* 0x4D (M) API Identifier Bytes 6-7 Bytes 8 Byte 9 0x4E (N) 0x4A (J) 0x40 0xD2 AT Command Parameter Value Checksum Frame ID** * Length [Bytes] = API Identifier + Frame ID + AT Command + Parameter Value ** “M” value was arbitrarily selected. A string parameter used with the NI (Node Identifier), ND (Node Discover) and DH (Destination Address High) command is terminated with a 0x00 character. AT Command - Queue Parameter Value API Identifier Value: (0x09) This API type allows module parameters to be queried or set. In contrast to the “AT Command” API type, new parameter values are queued and not applied until either the “AT Command” (0x08) API type or the AC (Apply Changes) command is issued. Register queries (reading parameter values) are returned immediately. Figure 7‐9. Start Delimiter 0x7E AT Command Frames (Note that frames are identical to the “AT Command” API type except for the API identifier.) Length MSB LSB Frame Data Checksum API-specific Structure 1 Byte API Identifier Identifier-specific Data 0x09 cmdData Frame ID (Byte 5) AT Command (Bytes 6-7) Identifies the UART data frame for the host to correlate with a subsequent ACK (acknowledgement). If set to ‘0’, no response is sent. Command Name - Two ASCII characters that identify the AT Command. © 2007 Digi International, Inc. Parameter Value (Byte(s) 8-n) If present, indicates the requested parameter value to set the given register. If no characters present, register is queried. 46 XBee Series 2/XBee Series 2 PRO ZigBee OEM RF Modules v1.x2x AT Command Response API Identifier Value: (0x88) Response to previous command. In response to an AT Command message, the module will send an AT Command Response message. Some commands will send back multiple frames (for example, the ND (Node Discover) command). Figure 7‐10. AT Command Response Frames. Start Delimiter 0x7E Length MSB LSB Frame Data Checksum API-specific Structure 1 Byte API Identifier Identifier-specific Data 0x88 cmdData Frame ID (Byte 5 ) AT Command (Bytes 6-7) Identifies the UART data frame being reported. Note: If Frame ID = 0 in AT Command Mode, no AT Command Response will be given. Command Name - Two ASCII characters that identify the AT Command. Status (Byte 8) Value (Byte(s) 9-n) OK ERROR Invalid Command Invalid Parameter The HEX (non-ASCII) value of the requested register Remote AT Command Request API Identifier Value: (0x17) Allows for module parameter registers on a remote device to be queried or set Figure 7‐11. Remote AT Command Request Start Delimiter 0x7E Length MSB LSB Frame Data Checksum API-specific Structure 1 Byte API Identifier Identifier-specific Data 0x017 Frame ID (Byte 5) Identifies the UART data frame being reported. If Frame ID = 0, no AT command response will be given 64-bit Destination Address (bytes 6-13) Set to match the 64-bit address of the destination, MSB first, LSB last. Broadcast = 0x000000000000FFFF. cmdData 16-bit Destination Network Address (bytes 14-15) Set to match the 16-bit network address of the destination, MSB first, LSB last. Set to 0xFFFE for broadcast TX, or if the network address is unknown. Command Name (bytes 17-18) Name of the command Command Options (byte 16) 0x02 - Apply changes on remote. (If not set, AC command must be sent before changes will take effect.) All other bits must be set to 0. © 2007 Digi International, Inc. Command Data (byte 19-n) If present, indicates the requested parameter value to set the given register. If no characters present, the register is queried. 47 XBee Series 2/XBee Series 2 PRO ZigBee OEM RF Modules v1.x2x Remote Command Response API Identifier Value: (0x97) If a module receives a remote command response RF data frame in response to a Remote AT Command Request, the module will send a Remote AT Command Response message out the UART. Some commands may send back multiple frames--for example, Node Discover (ND) command. Figure 7‐12. Remote AT Command Response. Start Delimiter 0x7E Length MSB LSB Frame Data Checksum API-specific Structure 1 Byte API Identifier Identifier-specific Data 0x97 cmdData Frame ID (Byte 5) 64-bit Responder Address (bytes 6-13) Identifies the UART data frame being reported. Matches the Frame ID of the Remote Command Request the remote is responding to. 16-bit Responder Network Address (bytes 14-15) Indicates the 64-bit address of the remote module that is responding to the Remote AT Command request Set to the 16-bit network address of the remote. Set to 0xFFFE if unknown. Command Name (bytes 16-17) Name of the command. Two ASCII characters that identify the AT command Status (byte 18) 0 = OK 1 = Error 2 = Invalid Command 3 = Invalid Parameter Command Data (byte 19-n) The value of the requested register. ZigBee Transmit Request API Identifier Value: (0x10) A TX Request message will cause the module to send RF Data as an RF Packet.TX Packet Frames © 2007 Digi International, Inc. 48 XBee Series 2/XBee Series 2 PRO ZigBee OEM RF Modules v1.x2x Figure 7‐13. ZigBee Transmit Request. Start delimiter Length 0x7E MSB LSB Frame Data API-specific Structure cmdData 0x10 Identifies the UART data frame for the host to correlate with a subsequent ACK (acknowledgement). Setting Frame ID to ‘0' will disable response frame. 1 Byte Identifier specific data API Identifier Frame ID (byte 5) Checksum 16-bit Destination Network Address (bytes 14-15) MSB first, LSB last. Set to 0xFFFE for Broadcast TX or if Network Address is not known 64-bit Address (bytes 6-13) MSB first, LSB last. Broadcast = 0x000000000000FFFF © 2007 Digi International, Inc. Options (byte 17) 0x08 - Send multicast transmission. (Unicast sent if not set.) All other bits must be set to 0. RF Data: Bytes (s) 18-n Up to 72 Bytes per packet Broadcast Radius (byte 16) Sets maximum number of hops a broadcast transmission can traverse. If set to 0, the TX radius will be set to the network maximum hops value (10). 49 XBee Series 2/XBee Series 2 PRO ZigBee OEM RF Modules v1.x2x Explicit Addressing ZigBee Command Frame API Identifier Value: (0x11) Allows ZigBee application layer fields (endpoint and cluster ID) to be specified for a data transmission. Figure 7‐14. Explicit Addressing ZigBee Command Frame. Start delimiter 0x7E Length MSB Frame Data LSB Checksum API-specific Structure API Identifier Identifier specific data 0x12 Frame ID (byte 5) 1 Byte cmdData Identifies the UART data frame for the host correlate with a subsequent ACK (acknowledgement). Setting Frame ID to ‘ 0’ will disable response frame. Reserved (byte 18) Set to 0 Cluster ID (byte 19) 64-bit Destination Address (bytes 6-13) Cluster ID used in the transmission Destination 64-bit (extended) address. Set to 0xFFFF for broadcast. 16-bit Destination Network Address (byted 14-15) Destination network address (if known). Set to 0xFFFE for broadcast transmissions or if the destination network address is not known. Source endpoint (byte 16) Source endpoint for the transmission . Destination endpoint (byte 17) Destination endpoint for the transmission. © 2007 Digi International, Inc. Profile ID (bytes 20-21) Multiple profile IDs not supported. Set to 0xC105. Broadcast Radius (byte 22) Sets the maximum number of hops a broadcast transmission can traverse. If set to 0, the transmission radius will be set to the network maximum hops value. Options (byte 23) 10 0x08 - Send multicast transmission (unicast sent if not set ). All other bits must be set to 0. 11 RF Data (byte 24-n) Up to 72 bytes 50 XBee Series 2/XBee Series 2 PRO ZigBee OEM RF Modules v1.x2x ZigBee Transmit Status API Identifier Value: 0x8B When a TX Request is completed, the module sends a TX Status message. This message will indicate if the packet was transmitted successfully or if there was a failure. Figure 7‐15. TX Status Frames Start Delimiter 0x7E Length MSB Frame ID (Byte 5) LSB Frame Data Checksum API-specific Structure 1 Byte API Identifier Identifier-specific Data 0x8B cmdData Remote Network Address (Bytes 6-7) Identifies UART data frame being reported. 16-bit Network Address the packet was delivered to (if success). If not success, this address matches the Destination Network Address that was provided in the Transmit Request Frame. Transmit Retry Count (Byte 8) The number of application transmission retries that took place. Delivery Status (Byte 9) 0x00 = Success 0x02 = CCA Failure 0x15 = Invalid destination endpoint 0x21 = Network ACK Failure 0x22 = Not Joined to Network 0x23 = Self-addressed 0x24 = Address Not Found 0x25 = Route Not Found Discovery Status (Byte 10) 0x00 = No Discovery Overhead 0x01 = Address Discovery 0x02 = Route Discovery 0x03 = Address and Route Discovery ZigBee Receive Packet API Identifier Value: (0x90) When the module receives an RF packet, it is sent out the UART using this message type. Figure 7‐16. RX Packet Frames Start Delimiter 0x7E 64-bit Address (Bytes 5-12) MSB (most significant byte) first, LSB (least significant) last Length MSB LSB Frame Data Checksum API-specific Structure 1 Byte API Identifier Identifier-specific Data 0x90 cmdData 16-bit Network Address (Bytes 13-14) MSB (most significant byte) first, LSB (least significant) last © 2007 Digi International, Inc. Options (Byte 15) 0x01 - Packet Acknowledged 0x02 - Packet was a broadcast packet RF Data (Byte(s) 16-n) Up to 72 Bytes per packet 51 XBee Series 2/XBee Series 2 PRO ZigBee OEM RF Modules v1.x2x ZigBee Explicit Rx Indicator API Identifier Value:(0x91) When the modem receives a ZigBee RF packet it is sent out the UART using this message type (when AO=1). Figure 7‐17. ZigBee Explicit Rx Indicators Start delimiter 0x7E Length MSB Frame Data LSB Checksum API-specific Structure 1 Byte Identifier specific data AP Identifier 0x91 cmdData Cluster ID (byte 17-18) 64-bit Source address (bytes 5-12) Destination 64-bit (extended) address. Set to 0xFFFF for broadcast. Cluster ID the packet was addressed to. Profile ID (byte 19-20) 16-bit Source network address (13-14) Destination network address (if known). Set to 0xFFFE for broadcast transmissions or if the destination network address is not known. Profile ID the packet was addressed to. (Multiple profile IDs not yet supported .) Options (byte 21) Source endpoint (byte 15) 0x01 – Packet Acknowledged 0x02 – Packet was a broadcast packet Endpoint of the source that initiated the transmission RF data (byte 22-n) Destination endpoint (byte 16) Up to 72 bytes. Endpoint of the destination the message is addressed to. XBee Sensor Read Indicator API Identifier Value: 0x94 When the module receives a sensor sample, it is sent out the UART using this message type (when AO=0). © 2007 Digi International, Inc. 52 XBee Series 2/XBee Series 2 PRO ZigBee OEM RF Modules v1.x2x Figure 7‐18. XBee Sensor Read Indicator (0x94) © 2007 Digi International, Inc. 53 XBee Series 2/XBee Series 2 PRO ZigBee OEM RF Modules v1.x2x Node Identification Indicator API Identifier Value: 0x95 This frame is received on the coordinator when a module transmits a node identification message to identify itself to the coordinator (when AO=0). The data portion of this frame is similar to a Node Discovery response frame (see ND command). Figure 7‐19. Node Identification Indicator © 2007 Digi International, Inc. 54 8. Examples 8.0.1. Starting an XBee Network Start the coordinator 1. Determine the operating channels list using the SC (Scan Channels) command and the PAN ID to operate using the ID (PAN ID) command. The default SD (Scan Duration) parameter value should suffice. If these values are changed from the defaults, they should be written to non-volatile memory using the WR (Write) command. 2. The Associate LED, if enabled using the D5 (DIO5 Configuration) parameter, will start blinking 1x per second once the coordinator has started. If API is enabled (AP parameter > 0): The API Modem Status “Coordinator Started” is sent out the UART. 3. The AI (Association Indication) parameter will be 0 signifying a successful startup. 4. The MY (16-bit Source address) attribute is 0 (the 16-bit network address of a ZigBee coordinator). 5. After startup, the coordinator will allow joining based on its NJ (Node Join Time) value. 6. It is recommended that the coordinator be configured with an NI-String identifier. This NIString identifier should be written to non-volatile memory using the WR (Write) command to be preserved through power-loss. Adding a Child (router) 1. Determine the operating channel list (SC) and the desired PAN ID to join (ID) (0xFFFF - join any Pan). The default SD parameter should suffice. If these values are changed from the defaults, they should be written to non-volatile memory using the WR (Write) command. 2. The router, on power-up, will attempt to locate a parent to join according to its SC and ID parameters. 3. Once the router has joined a parent, the Associate LED, if enabled (D5), will start blinking 2x per second. The ID and CH parameters will reflect the operating PAN ID and Channel. The MY parameter will reflect the 16-bit network address of the router. 4. If the router is not joining as expected, the AI (Association Indication) parameter can be read to determine the cause of failure. If API is enabled (AP parameter > 0): The API Modem Status “Joined” is sent out the UART. Verify the PAN contains a coordinator or nearby joined router that has matching Channel (SC, CH) and PAN ID (ID) settings and is allowing nodes to join to it (NJ parameter). 5. Once the router has joined a PAN, the router will allow joining based on the NJ parameter. 6. It is recommended that the router be configured with a unique NI-String identifier. This NIString identifier should be written to non-volatile memory using the WR (Write) command to be preserved through power-loss. Transmit Data (AT Firmware) 1. Start a coordinator (refer to instructions above). 2. Add one or more Child router(s) to the coordinator (refer to instructions above). 3. Once the coordinator has started, all routers and End Devices should join to a parent and their Associate LED should blink 2x per second. 4. If any nodes have not joined, read the AI command to determine why. 5. Issue the ATND command on the coordinator to get a list of all nodes on the network. 6. Use the ‘Terminal’ tab of the X-CTU Software to send serial data between nodes. The data should be transmitted from the source to the destination node as specified by the DH & DL parameters. 7. (Optional) Change the Destination address on any node to one of the 64-bit addresses discovered using the ND command in step 5 (DH, DL Commands, or in the ‘ZigBee Transmit Request’ API Frame). Then repeat step 6 to transmit data. © 2007 Digi International, Inc. 55 XBee Series 2/XBee Series 2 PRO ZigBee OEM RF Modules v1.x2x 8.0.2. AT Command Programming Examples Setup Refer to the ‘X‐CTU’ sec‐ tion of the Develop‐ ment Guide [Appendix B] for more information regarding the X‐CTU configuration software. The programming examples in this section require the installation of Digi's X-CTU Software and a serial connection to a PC. (Digi stocks RS-232 and USB boards to facilitate interfacing with a PC.) 1. Install Digi's X-CTU Software to a PC by double-clicking the "setup_X-CTU.exe" file. 2. Mount the RF module to an interface board, then connect the module assembly to a PC. 3. Launch the X-CTU Software and select the 'PC Settings' tab. Verify the baud and parity settings of the Com Port match those of the RF module. NOTE: Failure to enter AT Command Mode is most commonly due to baud rate mismatch. Ensure the ‘Baud’ setting on the ‘PC Settings’ tab matches the interface data rate of the RF module. By default, the BD parameter = 3 (which corresponds to 9600 bps). Sample Configuration: Modify RF Module Destination Address Example: Utilize the X-CTU “Terminal” tab to change the RF module's DL (Destination Address Low) parameter and save the new address to non-volatile memory. After establishing a serial connection between the RF module and a PC [refer to the 'Setup' section above], select the “Terminal” tab of the X-CTU Software and enter the following command lines (‘CR’ stands for carriage return): Method 1 (One line per command) Send AT Command +++ ATDL ATDL1A0D ATWR ATCN System Response OK (Enter into Command Mode) {current value} (Read Destination Address Low) OK (Modify Destination Address Low) OK (Write to non-volatile memory) OK (Exit Command Mode) Method 2 (Multiple commands on one line) Send AT Command +++ ATDL ATDL1A0D,WR,CN System Response OK (Enter into Command Mode) {current value} (Read Destination Address Low) OK OK OK Sample Configuration: Restore RF Module Defaults Example: Utilize the X-CTU “Modem Configuration” tab to restore default parameter values. After establishing a connection between the module and a PC [refer to the 'Setup' section above], select the “Modem Configuration” tab of the X-CTU Software. 1. Select the 'Read' button. 2. Select the 'Restore' button. 8.0.3. API Programming Examples API Configuration Using the X-CTU The programming examples in this section require the installation of Digi's X-CTU soware and a serial connection to a PC. See "Setup" example in the AT Command Programming Examples in Section 8.0.2. 1. Launch the X-CTU Software and select the 'PC Settings' tab. Verify the baud and parity settings of the Com Port match those of the RF module. 2. To communicate with a module that has API firmware, check the "Enable API" box. 3. If escaping is enabled (AP=2, non-default setting), select the "Use escape characters" box to enable escaping. 4. Select the 'Modem Configuration' tab. 5. The 'Read', 'Write', and 'Restore' buttons can be used to read module parameters, write new settings, or restore defaults. © 2007 Digi International, Inc. 56 XBee Series 2/XBee Series 2 PRO ZigBee OEM RF Modules v1.x2x Constructing API Frames Example: Create an API AT command frame to configure an XBee to allow joining (set NJ to 0xFF). The frame should look like: 0x7E 0x00 0x05 0x08 0x01 0x4E 0x4A 0xFF 5F Where 0x0005 = length 0x08 = AT Command API frame type 0x01 = Frame ID (set to non-zero value) 0x4E4A = AT Command ('NJ') 0xFF = value to set command to 0x5F = Checksum The checksum is calculated as [0xFF - (0x08 + 0x01 + 0x4E + 0x4A + 0xFF)] Example: Send a transmission to a module with destination address 0x0013A200 40014011, payload "TxData1B". If escaping is disabled, (AP=1), the frame should look like: 0x7E 0x00 0x16 0x10 0x01 0x00 0x13 0xA2 0x00 0x40 0x0A 0x01 0x27 0xFF 0xFE 0x00 0x00 0x54 0x78 0x44 0x61 0x74 0x61 0x30 0x41 0x13 Where 0x16 = length (22 bytes excluding checksum) 0x10 = ZigBee Transmit Request API frame type 0x01 = Frame ID (set to non-zero value) 0x0013A200400A0127 = 64-bit Destination Address 0xFFFE = 16-bit Destination Address 0x00 = Broadcast radius 0x00 = Options 0x5478446174613041 = Data payload ("TxData0A") 0x64 = Checksum If escaping is enabled (AP=2), the frame should look like: 0x7E 0x00 0x16 0x10 0x01 0x00 0x7D 0x33 0xA2 0x00 0x40 0x0A 0x01 0x27 0xFF 0xFE 0x00 0x00 0x54 0x78 0x44 0x61 0x74 0x61 0x30 0x41 0x7D 0x33 The checksum is calculated (on all non-escaped bytes) as [0xFF - (sum of all bytes from API frame type through data payload)]. Example: Send a transmission to the coordinator without specifying the coordinator's 64-bit address. The API transmit request frame should look like: 0x7E 0x00 0x16 0x10 0x01 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0xFF 0xFE 0x00 0x00 0x54 0x78 032 0x43 0x6F 0x6F 0x72 0x64 0xFC Where 0x16 = length (22 bytes excluding checksum) 0x10 = ZigBee Transmit Request API frame type 0x01 = Frame ID (set to non-zero value) 0x0000000000000000 = Coordinator's address (can be replaced with coordinator's actual 64-bit address if known 0xFFFE = 16-bit Destination Address 0x00 = Broadcast radius 0x00 = Options 0x547832436F6F7264 = Data payload ("Tx2Coord") 0xFC = Checksum © 2007 Digi International, Inc. 57 9. Manufacturing Support 9.1. Interoperability with other EM250 Devices The XBee module can interoperate with other EM250-based devices. The following should be considered when communicating between a Digi XBee module and another EM250-based device. The XBee firmware inserts 8 bytes at the beginning of the data payload that represent the 64-bit address of the source module. Custom devices that transmit to an XBee or receive data from an XBee should make provisions to manage these 8 address bytes in the payload. Data packets destined for an XBee module should include the source address of the sending device with the most significant byte copied first. 9.2. Customizing XBee Default Parameters Once module parameters are determined, Digi can manufacture modules with specific customerdefined configurations. These custom configurations can lock in a firmware version or set command values when the modules are manufactured, eliminating the need for customers to adjust module parameters on arrival. Contact Digi to create a custom configuration. 9.3. XBee Series 2 Custom Bootloader XBee Series 2 modules use a modified version of Ember’s boot loader. This bootloader version supports a custom entry mechanism that uses module pins DIN (pin 3), DTR / SLEEP_RQ (pin 9), and RTS (pin 16). To invoke the boot loader, do the following: 1. Set DTR / SLEEP_RQ low (TTL 0V) and RTS high. 2. Send a serial break to the DIN pin and power cycle or reset the module. 3. When the module powers up, DTR / SLEEP_RQ and DIN should be low (TTL 0V) and RTS should be high. 4. Terminate the serial break and send a carriage return at 115200bps to the module. 5. If successful, the module will send the Ember boot loader menu out the DOUT pin at 115200bps. 6. Commands can be sent to the boot loader at 115200bps. 9.4. Programming XBee Series 2 Modules Firmware on the XBee Series 2 modules can be upgraded using the Digi x-CTU program to interface with the DIN and DOUT serial lines, or with an InSight programmer device via InSight header. 9.5. XBee EM250 Pin Mappings The following table shows how the GPIO pins on the EM250 map to pins on the XBee Series 2 module: Table 9‐011. XBee Series 2 Module Pin Number EM250 GPIO XBee Series 2 Module Pin Number EM250 GPIO 13 11 12 12 10 13 14 15 © 2007 Digi International, Inc. 58 XBee Series 2/XBee Series 2 PRO ZigBee OEM RF Modules v1.x2x Table 9‐011. XBee Series 2 Module Pin Number EM250 GPIO XBee Series 2 Module Pin Number EM250 GPIO 11 15 16 16 17 18 14 19 10 20 © 2007 Digi International, Inc. 59 Appendix A: Definitions Definitions Table A‐01. Terms and Definitions ZigBee Node Types Coordinator A node that has the unique function of forming a network. The coordinator is responsible for establishing the operating channel and PAN ID for an entire network. Once established, the coordinator can form a network by allowing routers and end devices to join to it. Once the network is formed, the coordinator functions like a router (it can participate in routing packets and be a source or destination for data packets). ------ One coordinator per PAN Establishes/Organizes PAN Can route data packets to/from other nodes Can be a data packet source and destination Mains-powered Refer to the XBee Series 2 coordinator section for more information. Router A node that creates/maintains network information and uses this information to determine the best route for a data packet. A router must join a network before it can allow other routers and end devices to join to it. A router can participate in routing packets and is intended to be a mains-powered node. ----- Several routers can operate in one PAN Can route data packets to/from other nodes Can be a data packet source and destination Mains-powered Refer to the XBee Series 2 router section for more information. End device End devices must always interact with their parent to receive or transmit data. (See ‘joining definition.) They are intended to sleep periodically and therefore have no routing capacity. An end device can be a source or destination for data packets but cannot route packets. End devices can be battery-powered and offer low-power operation. ----- Several end devices can operate in one PAN Can be a data packet source and destination All messages are relayed through a coordinator or router Lower power modes ZigBee Protocol PAN Personal Area Network - A data communication network that includes a coordinator and one or more routers/end devices. © 2007 Digi International, Inc. 60 XBee Series 2/XBee Series 2 PRO ZigBee OEM RF Modules v1.x2x Table A‐01. Terms and Definitions Joining The process of a node becoming part of a ZigBee PAN. A node becomes part of a network by joining to a coordinator or a router (that has previously joined to the network). During the process of joining, the node that allowed joining (the parent) assigns a 16-bit address to the joining node (the child). Network Address The 16-bit address assigned to a node after it has joined to another node. The coordinator always has a network address of 0. Operating Channel The frequency selected for data communications between nodes. The operating channel is selected by the coordinator on power-up. Energy Scan A scan of RF channels that detects the amount of energy present on the selected channels. The coordinator uses the energy scan to determine the operating channel. Route Request Broadcast transmission sent by a coordinator or router throughout the network in attempt to establish a route to a destination node. Route Reply Unicast transmission sent back to the originator of the route request. It is initiated by a node when it receives a route request packet and its address matches the Destination Address in the route request packet. Route Discovery The process of establishing a route to a destination node when one does not exist in the Routing Table. It is based on the AODV (Ad-hoc On-demand Distance Vector routing) protocol. ZigBee Stack ZigBee is a published specification set of high-level communication protocols for use with small, low-power modules. The ZigBee stack provides a layer of network functionality on top of the 802.15.4 specification. For example, the mesh and routing capabilities available to ZigBee solutions are absent in the 802.15.4 protocol. © 2007 Digi International, Inc. 61 Appendix B: Agency Certifications United States FCC The XBee Series 2 RF Module complies with Part 15 of the FCC rules and regulations. Compliance with the labeling requirements, FCC notices and antenna usage guidelines is required. To fufill FCC Certification, the OEM must comply with the following regulations: 1. The system integrator must ensure that the text on the external label provided with this device is placed on the outside of the final product. [Figure A-01] 2. XBee Series 2 RF Module may only be used with antennas that have been tested and approved for use with this module [refer to the antenna tables in this section]. OEM Labeling Requirements WARNING: The Original Equipment Manufacturer (OEM) must ensure that FCC labeling requirements are met. This includes a clearly visible label on the outside of the final product enclosure that displays the contents shown in the figure below. Required FCC Label for OEM products containing the XBee Series 2 RF Module Contains FCC ID: OUR-XBEE2* The enclosed device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (i.) this device may not cause harmful interference and (ii.) this device must accept any interference received, including interference that may cause undesired operation. Required FCC Label for OEM products containing the XBee Series 2 PRO RF Module Contains FCC ID:MCQ-XBEEPRO2* The enclosed device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (i.) this device may not cause harmful interference and (ii.) this device must accept any interference received, including interference that may cause undesired operation. FCC Notices IMPORTANT: The XBee Series 2 and XBEE Series 2 PRO RF Module have been certified by the FCC for use with other products without any further certification (as per FCC section 2.1091). Modifications not expressly approved by Digi could void the user's authority to operate the equipment. IMPORTANT: OEMs must test final product to comply with unintentional radiators (FCC section 15.107 & 15.109) before declaring compliance of their final product to Part 15 of the FCC Rules. IMPORTANT: The RF module has been certified for remote and base radio applications. If the module will be used for portable applications, the device must undergo SAR testing. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Re-orient or relocate the receiving antenna, Increase the separation between the equipment and receiver, Connect equipment and receiver to outlets on different circuits, or Consult the dealer or an experienced radio/TV technician for help. © 2007 Digi International, Inc. 62 XBee Series 2/XBee Series 2 PRO ZigBee OEM RF Modules v1.x2x FCC-Approved Antennas (2.4 GHz) The XBee Series 2 and XBee Series 2 PRO RF Module can be installed utilizing antennas and cables constructed with standard connectors (Type-N, SMA, TNC, etc.) if the installation is performed professionally and according to FCC guidelines. For installations not performed by a professional, non-standard connectors (RPSMA, RPTNC, etc.) must be used. The modules are FCC approved for fixed base station and mobile applications on channels 0x0B0x1A for Xbee Series2 and on channels 0x0B - 0x18 for Xbee Series2 Pro. If the antenna is mounted at least 20cm (8 in.) from nearby persons, the application is considered a mobile application. Antennas not listed in the table must be tested to comply with FCC Section 15.203 (Unique Antenna Connectors) and Section 15.247 (Emissions). XBee Series 2 RF Modules: XBee Series 2 RF Modules have been tested and approved for use with all the antennas listed in the tables below. (Cable-loss IS required when using gain antennas as shown below.) Table A‐01. Antennas approved for use with the XBee/XBee‐PRO OEM RF Modules (all 2.4 GHz) YAGI CLASS ANTENNAS Application* Min. Separation Required Dipole (Half-wave bulkhead mount articulated MMCX w/ 2.1 dBi pigtail) Fixed/Mobile* 20 cm A24-HBMM-PSI Dipole (Half-wave bulkhead mount MMCX w/ pigtail) 2.1 dBi Fixed/Mobile* 20 cm A24-HABSM Dipole (Articulated RPSMA) 2.1 dBi Fixed/Mobile* 20 cm A24-QBMM-PSI Monopole (Quarter-wave bulkhead mount MMCX w/ pigtail) 1.9 dBi Fixed/Mobile* 20 cm A24-QABMM-PSI Monopole (Quarter-wave bulkhead mount articulated MMCX w/pigtail) 1.9 dBi Fixed/Mobile* 20 cm A24-QI Monopole (Integrated whip) 1.9 dBi Fixed/Mobile* 20 cm A24-C1 Surface Mount -1.5 dBi Fixed/Mobile* 20 cm A24-Y4NF Yagi (4-element) 6.0 dBi Fixed* 2m A24-Y6NF Yagi (6-element) 8.8 dBi Fixed* 2m A24-Y7NF Yagi (7-element) 9.0 dBi Fixed* 2m A24-Y9NF Yagi (9-element) 10.0 dBi Fixed* 2m A24-Y10NF Yagi (10-element) 11.0 dBi Fixed* 2m A24-Y12NF Yagi (12-element) 12.0 dBi Fixed* 2m A24-Y13NF Yagi (13-element) 12.0 dBi Fixed* 2m A24-Y15NF Yagi (15-element) 12.5 dBi Fixed* 2m A24-Y16NF Yagi (16-element) 13.5 dBi Fixed* 2m A24-Y16RM Yagi (16-element, RPSMA connector) 13.5 dBi Fixed* 2m A24-Y18NF Yagi (18-element) 15.0 dBi Fixed* Part Number Type (Description) A24-HABMM-PSI Gain 2m 20 cm A24-F2NF Omni-directional (Fiberglass base station) 2.1 dBi Fixed/Mobile* A24-F3NF Omni-directional (Fiberglass base station) 3.0 dBi Fixed/Mobile* A24-F5NF Omni-directional (Fiberglass base station) 5.0 dBi Fixed/Mobile* 20 cm A24-F8NF Omni-directional (Fiberglass base station) 8.0 dBi Fixed* 2m A24-F9NF Omni-directional (Fiberglass base station) 9.5 dBi Fixed* 2m A24-F10NF Omni-directional (Fiberglass base station) 10.0 dBi Fixed* 2m A24-F12NF Omni-directional (Fiberglass base station) 12.0 dBi Fixed* 2m A24-F15NF Omni-directional (Fiberglass base station) 15.0 dBi Fixed* 2m A24-W7NF Omni-directiMonal (Base station) 7.2 dBi Fixed* 2m Omni-directional (Mag-mount base station) 7.2 dBi Fixed* 2m A24-M7NF 20 cm A24-P8SF Flat Panel 8.5 dBi Fixed* 2m A24-P8NF Flat Panel 8.5 dBi Fixed* 2m A24-P13NF Flat Panel 3.0 dBi Fixed* 12 m A24-P14NF Flat Panel 14.0 dBi Fixed* 2m © 2007 Digi International, Inc. 63 XBee Series 2/XBee Series 2 PRO ZigBee OEM RF Modules v1.x2x YAGI CLASS ANTENNAS Part Number Type (Description) Gain Application* Min. Separation Required 2m A24-P15NF Flat Panel 15.0 dBi Fixed* A24-P16NF Flat Panel 16.0 dBi Fixed* 2m A24-P19NF Flat Panel 19.0 dBi Fixed* 2m Table A‐02. antennas approved for use with the XBee Series 2 RF Modules YAGI CLASS ANTENNAS Part Number Type (Description) Gain Application* A24-Y6NF A24-Y7NF A24-Y9NF A24-Y10NF A24-Y12NF A24-Y13NF A24-Y15NF A24-Y16NF A24-Y16RM A24-Y18NF Yagi (6-element) Yagi (7-element) Yagi (9-element) Yagi (10-element) Yagi (12-element) Yagi (13-element) Yagi (15-element) Yagi (16-element) Yagi (16-element, RPSMA connector) Yagi (18-element) 8.8 dBi 9.0 dBi 10.0 dBi 11.0 dBi 12.0 dBi 12.0 dBi 12.5 dBi 13.5 dBi 13.5 dBi 15.0 dBi Fixed Fixed Fixed Fixed Fixed Fixed Fixed Fixed Fixed Fixed Min. Separation Required 2m 2m 2m 2m 2m 2m 2m 2m 2m 2m Cable-loss 7.8dB 8 dB 9 dB 10 dB 11 dB 11 dB 11.5 dB 12.5 dB 12.5 dB 14 dB OMNI-DIRECTIONAL ANTENNAS Part Number Type (Description) Gain Application* A24-C1 A24-F2NF A24-F3NF A24-F5NF A24-F8NF A24-F9NF A24-F10NF A24-F12NF A24-F15NF A24-W7NF A24-M7NF Surface Mount integral chip Omni-directional (Fiberglass base station) Omni-directional (Fiberglass base station) Omni-directional (Fiberglass base station) Omni-directional (Fiberglass base station) Omni-directional (Fiberglass base station) Omni-directional (Fiberglass base station) Omni-directional (Fiberglass base station) Omni-directional (Fiberglass base station) Omni-directional (Base station) Omni-directional (Mag-mount base station) 1.5 dBi 2.1 dBi 3.0 dBi 5.0 dBi 8.0 dBi 9.5 dBi 10.0 dBi 12.0 dBi 15.0 dBi 7.2 dBi 7.2 dBi Fixed/Mobile Fixed/Mobile Fixed/Mobile Fixed/Mobile Fixed Fixed Fixed Fixed Fixed Fixed Fixed Min. Separation Required 20 cm 20 cm 20 cm 20 cm 2m 2m 2m 2m 2m 2m 2m Cable-loss .3 dB 2.3 dB 5.3 dB 6.8 dB 7.3 dB 9.3dB 12.3dB 4.5 dB 4.5 dB PANEL CLASS ANTENNAS Part Number Type (Description) Gain Application* A24-P8SF A24-P8NF A24-P13NF A24-P14NF A24-P15NF A24-P16NF A24-P19NF Flat Panel Flat Panel Flat Panel Flat Panel Flat Panel Flat Panel Flat Panel 8.5 dBi 8.5 dBi 13.0 dBi 14.0 dBi 15.0 dBi 16.0 dBi 19.0 dBi Fixed Fixed Fixed Fixed Fixed Fixed Fixed Min. Separation Required 2m 2m 2m 2m 2m 2m 2m Cable-loss 8.2 dB 82 dB 12.7 dB 13.7 dB 14.7 dB 15.7 dB 18.7 dB Table A‐03. antennas approved for use with the XBee Series 2 PRO RF Modules YAGI CLASS ANTENNAS Part Number Type (Description) Gain Application* A24-Y6NF A24-Y7NF A24-Y9NF A24-Y10NF A24-Y12NF A24-Y13NF A24-Y15NF A24-Y16NF Yagi (6-element) Yagi (7-element) Yagi (9-element) Yagi (10-element) Yagi (12-element) Yagi (13-element) Yagi (15-element) Yagi (16-element) 8.8 dBi 9.0 dBi 10.0 dBi 11.0 dBi 12.0 dBi 12.0 dBi 12.5 dBi 13.5 dBi Fixed Fixed Fixed Fixed Fixed Fixed Fixed Fixed © 2007 Digi International, Inc. Min. Separation Required 2m 2m 2m 2m 2m 2m 2m 2m Cable-loss N/A N/A N/A N/A N/A N/A N/A N/A 64 XBee Series 2/XBee Series 2 PRO ZigBee OEM RF Modules v1.x2x YAGI CLASS ANTENNAS Part Number Type (Description) Gain Application* A24-Y16RM A24-Y18NF Yagi (16-element, RPSMA connector) Yagi (18-element) 13.5 dBi 15.0 dBi Fixed Fixed Min. Separation Cable-loss Required 2m N/A 2m N/A OMNI-DIRECTIONAL ANTENNAS Part Number Type (Description) Gain Application* A24-C1 Surface Mount integral chip 1.5 dBi Fixed/Mobile Min. Separation Cable-loss Required N/A 20 cm A24-F2NF Omni-directional (Fiberglass base station) 2.1 dBi Fixed/Mobile 20 cm A24-F3NF Omni-directional (Fiberglass base station) 3.0 dBi Fixed/Mobile 20 cm A24-F5NF Omni-directional (Fiberglass base station) 5.0 dBi Fixed/Mobile 20 cm A24-F8NF A24-F9NF A24-F10NF A24-F12NF A24-F15NF A24-W7NF A24-M7NF Omni-directional (Fiberglass base station) Omni-directional (Fiberglass base station) Omni-directional (Fiberglass base station) Omni-directional (Fiberglass base station) Omni-directional (Fiberglass base station) Omni-directional (Base station) Omni-directional (Mag-mount base station) 8.0 dBi 9.5 dBi 10.0 dBi 12.0 dBi 15.0 dBi 7.2 dBi 7.2 dBi Fixed Fixed Fixed Fixed Fixed Fixed Fixed 2m 2m 2m 2m 2m 2m 2m N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A PANEL CLASS ANTENNAS Part Number Type (Description) Gain Application* A24-P8SF A24-P8NF A24-P13NF A24-P14NF A24-P15NF A24-P16NF A24-P19NF Flat Panel Flat Panel Flat Panel Flat Panel Flat Panel Flat Panel Flat Panel 8.5 dBi 8.5 dBi 13.0 dBi 14.0 dBi 15.0 dBi 16.0 dBi 19.0 dBi Fixed Fixed Fixed Fixed Fixed Fixed Fixed Min. Separation Required 2m 2m 2m 2m 2m 2m 2m Cable-loss N/A N/A N/A N/A N/A N/A 1.5 dB * If using the RF module in a portable application (For example - If the module is used in a handheld device and the antenna is less than 20cm from the human body when the device is in operation): The integrator is responsible for passing additional SAR (Specific Absorption Rate) testing based on FCC rules 2.1091 and FCC Guidelines for Human Exposure to Radio Frequency Electromagnetic Fields, OET Bulletin and Supplement C. The testing results will be submitted to the FCC for approval prior to selling the integrated unit. The required SAR testing measures emissions from the module and how they affect the person. RF Exposure WARNING: To satisfy FCC RF exposure requirements for mobile transmitting devices, a separation distance of 20 cm or more should be maintained between the antenna of this device and persons during device operation. To ensure compliance, operations at closer than this distance are not recommended. The antenna used for this transmitter must not be co-located in conjunction with any other antenna or transmitter. The preceding statement must be included as a CAUTION statement in OEM product manuals in order to alert users of FCC RF Exposure compliance. Europe (ETSI) The XBee Series 2 RF Module has been certified for use in several European countries. For a complete list, refer to www.digi.com If the XBee Series 2 RF Modules are incorporated into a product, the manufacturer must ensure compliance of the final product to the European harmonized EMC and low-voltage/safety standards. A Declaration of Conformity must be issued for each of these standards and kept on file as described in Annex II of the R&TTE Directive. Furthermore, the manufacturer must maintain a copy of the XBee Series 2 user manual documentation and ensure the final product does not exceed the specified power ratings, antenna specifications, and/or installation requirements as specified in the user manual. If any of these specifications are exceeded in the final product, a submission must be made to a notified body for compliance testing to all required standards. © 2007 Digi International, Inc. 65 XBee Series 2/XBee Series 2 PRO ZigBee OEM RF Modules v1.x2x OEM Labeling Requirements The 'CE' marking must be affixed to a visible location on the OEM product. Figure B‐01. CE Labeling Requirements The CE mark shall consist of the initials "CE" taking the following form: • If the CE marking is reduced or enlarged, the proportions given in the above graduated drawing must be respected. • The CE marking must have a height of at least 5mm except where this is not possible on account of the nature of the apparatus. • The CE marking must be affixed visibly, legibly, and indelibly. Restrictions Power Output: The power output of the XBee Series 2 RF Module must not exceed 10 dBm. The power level is set using the PL command and the PL parameter must equal “0” (10 dBm). France: France imposes restrictions on the 2.4 GHz band. Go to www.art-telecom.Fr or contact MaxStream for more information. Norway: Norway prohibits operation near Ny-Alesund in Svalbard. More information can be found at the Norway Posts and Telecommunications site (www.npt.no). Declarations of Conformity Digi has issued Declarations of Conformity for the XBee Series 2 RF Modules concerning emissions, EMC and safety. Files are located in the 'documentation' folder of the Digi CD. Important Note Digi does not list the entire set of standards that must be met for each country. Digi customers assume full responsibility for learning and meeting the required guidelines for each country in their distribution market. For more information relating to European compliance of an OEM product incorporating the XBee Series 2 RF Module, contact Digi, or refer to the following web sites: CEPT ERC 70-03E - Technical Requirements, European restrictions and general requirements: Available at www.ero.dk/. R&TTE Directive - Equipment requirements, placement on market: Available at www.ero.dk/. Approved Antennas When integrating high-gain antennas, European regulations stipulate EIRP power maximums. Use the following guidelines to determine which antennas to design into an application. XBee Series 2 OEM Module The following antennas types have been tested and approved for use with the XBee Series 2 Module: Antenna Type: Yagi RF module was tested and approved with 15 dBi antenna gain with 1 dB cable-loss (EIRP Maimum of 14 dBm). Any Yagi type antenna with 14 dBi gain or less can be used with no cable-loss. Antenna Type: Omni-Directional RF module was tested and approved with 15 dBi antenna gain with 1 dB cable-loss (EIRP Maimum of 14 dBm). Any Omni-Directional type antenna with 14 dBi gain or less can be used with no cable-loss. © 2007 Digi International, Inc. 66 XBee Series 2/XBee Series 2 PRO ZigBee OEM RF Modules v1.x2x Antenna Type: Flat Panel RF module was tested and approved with 19 dBi antenna gain with 4.8 dB cable-loss (EIRP Maimum of 14.2 dBm). Any Flat Panel type antenna with 14.2 dBi gain or less can be used with no cable-loss. XBee Series 2 RF Module The following antennas have been tested and approved for use with the embedded XBee Series 2 RF Module: - Dipole (2.1 dBi, Omni-directional, Articulated RPSMA, Digi part number A24-HABSM) - Chip Antenna (-1.5 dBi) - Attached Monopole Whip (1.5 dBi) XBee Series 2 Pro RF Module The following antennas have been tested and approved for use with the embedded XBee Series 2 Pro RF Module: - Dipole (2.1 dBi, Omni-directional, Articulated RPSMA, Digi part number A24-HABSM) - Chip Antenna (-1.5 dBi) - Attached Monopole Whip (1.5 dBi). Canada (IC) Labeling Requirements Labeling requirements for Industry Canada are similar to those of the FCC. A clearly visible label on the outside of the final product enclosure must display the following text: Contains Model XBee Series 2 Radio, IC: 4214A-XBEE2 The integrator is responsible for its product to comply with IC ICES-003 & FCC Part 15, Sub. B Unintentional Radiators. ICES-003 is the same as FCC Part 15 Sub. B and Industry Canada accepts FCC test report or CISPR 22 test report for compliance with ICES-003. If it contains an XBee Series 2 Pro OEM Module, the clearly visible label on the outside of the final product enclosure must display the following text: Contains Model XBee Series 2 Pro Radio, IC: 1846A-XBEEPRO2 The integrator is responsible for its product to comply with IC ICES-003 & FCC Part 15, Sub. B Unintentional Radiators. ICES-003 is the same as FCC Part 15 Sub. B and Industry Canada accepts FCC test report or CISPR 22 test report for compliance with ICES-003. © 2007 Digi International, Inc. 67 Appendix C: Migrating from the 802.15.4 Protocol This following are some of the differences in the ZigBee firmware assuming familiarity with the 802.15.4 application: • ZigBee Command Set • Address Assignment • API / AT Firmware Versions Also, refer to the “Getting Started” section for more information. ZigBee Command Set Modified Commands • CH - Read Only command that displays the operating channel that was selected from SC. • MY - Read Only command that displays the assigned 16-bit network address of the device. • AI - ZigBee definitions added to this command. See documentation. • A1, A2 and CE commands are not supported. New Commands • NJ (Node Join Time) - This value determines how long a Coordinator or Router will allow other devices to join to it. This command is supported on Coordinators & Routers only. • MP (16-bit Parent Network Address). This value represents the 16-bit parent network address of the module. • BH (Broadcast Hops). This value sets the maximum number of hops for each broadcast data transmission. Setting this to 0 will use the maximum number of hops. API / AT Firmware Versions The 802.15.4 firmware supports the AP command for setting the module into No API (AP=0), API without escaping (AP=1), or API with escaping (AP=2) modes. The first digit in the 802.15.4 firmware versions is a '1'. The ZigBee firmware comes in different versions to support the API interface (AP 1, 2 modes) or the AT command set (AP 0 mode). The first digit in the ZigBee firmware versions is an '8'. The following is a list of firmware versions: • 1.0xx - Coordinator, AT Command support (Transparent Mode) • 1.1xx - Coordinator, API support (AP 1, 2) • 1.2xx - Router, End Device, AT Command support (Transparent Mode) • 1.3xx - Router, End Device, API support (AP 1, 2) © 2007 Digi International, Inc. 68 Appendix D: Development Guide XBee Series 2 Development Kits The XBee Series 2 Professional Development Kit includes the hardware and software needed to rapidly create long range wireless data links between nodes (XBee Series 2 Starter Kits that contain fewer modules and accessories are also available). Table D‐01. Items Included in the Development Kit Item Qty. Description Part # XBee Series 2 Module (1) OEM RF Module, AT Coordinator with wire antenna (1) OEM RF Module, AT Router/End Device with wire antenna (1) OEM RF Module, AT Router/End Device with U.FL antenna (1) OEM RF Module, AT Router/End Device with chip antenna (1) OEM RF Module, AT Router/End Device with SMA antenna XB24-BWIt-002 XB24-BWIT-004 XB24-BUIT-004 XB24-BCIT-004 XB24-BSIT-004 RS-232 Development Board Board for interfacing between modules and RS-232 nodes (Converts signal levels, displays diagnostic info, & more) XBIB-R USB Development Board Board for interfacing between modules & USB nodes (Converts signal levels, displays diagnostic info, & more) XBIB-U RS-232 Cable (6’, straight-through) Cable for connecting RS-232 interface board with DTE nodes (nodes that have a male serial DB-9 port - such as most PCs) JD2D3-CDS-6F USB Cable (6’) Cable for connecting USB interface board to USB nodes JU1U2-CSB-6F Serial Loopback Adapter [Red] Adapter for configuring the module assembly (module + RS-232 interface board) to function as a repeater for range testing JD2D3-CDL-A NULL Modem Adapter (male-to-male) [Black] Adapter for connecting the module assembly (module + RS-232 interface board) to other DCE (female DB-9) nodes JD2D2-CDN-A NULL Modem Adapter (female-to-female) [Gray] Adapter for connecting serial nodes. It allows users to bypass the radios to verify serial cabling is functioning properly. JD3D3-CDN-A JP5P2-9V11-6F Power Adapter (9VDC, 1 A) Adapter for powering the RS-232 development board Battery Clip (9V) Clip for remotely powering the RS-232 board w/ a 9V battery JP2P3-C2C-4I RPSMA Antenna RPSMA half-wave dipole antenna (2.4 GHz, 2.1 dB) A24-HASM-450 RF Cable Assembly Adapter for connecting RPSMA antenna to U.FL connector JF1R6-CR3-4I CD Documentation and Software MD0030 Quick Start Guide Step-by-step instruction on how to create wireless links & test range capabilities of the modules MD0026 Interfacing Options The development kit includes RS-232 and USB interface boards. The boards provide a connection to PC ports and therefore give access to the RF module registries. Parameters stored in the registry allow OEMs and integrators to customize the modules to suite the needs of their data radio systems. The following sections illustrate how to use the interface boards for development purposes. The MaxStream Interface board provides means for connecting the module to any node that has an available RS-232 or USB connector. Since the module requires signals to enter at TTL voltages, one of the main functions of the interface board is to convert signals between TTL levels and RS232 and USB levels. © 2007 Digi International, Inc. 69 XBee Series 2/XBee Series 2 PRO ZigBee OEM RF Modules v1.x2x Note: In the following sections, an OEM RF Module mounted to an interface board will be referred to as a "Module Assembly". RS-232 Development Board External Interface B-01a. Reset Switch The Reset Switch is used to reset (re-boot) the RF module. This switch only applies when using the configuration tabs of Digi’s X-CTU Software. Figure B‐01. Front View B-01b. I/O & Power LEDs LEDs indicate RF module activity as follows: Yellow (top LED) = Serial Data Out (to host) Green (middle) = Serial Data In (from host) Red (bottom) = Power/Association Indicator (Refer to the D5 (DIO5 Configuration) parameter) B‐01c. DB‐9 Serial Port B‐01d RSSI LEDs B‐01b. I/O & Power LEDs B‐01e. Power Connector B‐01a. Config Switch B-01c. Serial Port Standard female DB-9 (RS-232) connector. B-01d. RSSI LEDs RSSI LEDs indicate the amount of fade margin present in an active wireless link. Fade margin is defined as the difference between the incoming signal strength and the module's receiver sensitivity. LEDs ON LEDs ON LED ON LED ON Very Strong Signal (> 30 dB fade margin) Strong Signal (> 20 dB fade margin) Moderate Signal (> 10 dB fade margin) Weak Signal (< 10 dB fade margin) B-01e. Power Connector 5-14 VDC power connector B-02a. DIP Switch Figure B‐02. Back View DIP Switch functions are not supported in this release. Future downloadable firmware versions will support DIP Switch configurations. B‐02a. DIP Switch © 2007 Digi International, Inc. 70 XBee Series 2/XBee Series 2 PRO ZigBee OEM RF Modules v1.x2x RS-232 Pin Signals Figure B‐03. Pins used on the female RS‐232 (DB‐9) Serial Connector Table D‐02. Pin Assignments and Implementations DB-9 Pin RS-232 Name Description Implementation* DCD Data-Carrier-Detect Connected to DSR (pin6) RXD Receive Data Serial data exiting the module assembly (to host) TXD Transmit Data Serial data entering into the module assembly (from host) DTR Data-Terminal-Ready Can enable Power-Down on the module assembly GND Ground Signal Ground DSR Data-Set-Ready Connected to DCD (pin1) RTS / CMD Request-to-Send / Command Mode Provides RTS flow control or enables Command Mode CTS Clear-to-Send Provides CTS flow control RI Ring Indicator Optional power input that is connected internally to the positive lead of the front power connector * Functions listed in the implementation column may not be available at the time of release. © 2007 Digi International, Inc. 71 XBee Series 2/XBee Series 2 PRO ZigBee OEM RF Modules v1.x2x Wiring Diagrams Figure B‐04. DTE node (RS‐232, male DB‐9 connector) wired to a DCE Module Assembly (female DB‐9) © 2007 Digi International, Inc. 72 XBee Series 2/XBee Series 2 PRO ZigBee OEM RF Modules v1.x2x Figure B‐05. DCE Module Assembly (female DB‐9 connector) wired to a DCE node (RS‐232, male DB‐9) Sample Wireless Connection: DTE <--> DCE <--> DCE <--> DCE Figure B‐06. Typical wireless link between DTE and DCE nodes © 2007 Digi International, Inc. 73 XBee Series 2/XBee Series 2 PRO ZigBee OEM RF Modules v1.x2x Adapters The development kit includes several adapters that support the following functions: • Performing Range Tests • Testing Cables • Connecting to other RS-232 DCE and DTE nodes • Connecting to terminal blocks or RJ-45 (for RS-485/422 nodes) NULL Modem Adapter (male-to-male) Part Number: JD2D2-CDN-A (Black, DB-9 M-M) The male-to-male NULL modem adapter is used to connect two DCE nodes. A DCE node connects with a straight-through cable to the male serial port of a computer (DTE). Figure B‐07. Male NULL modem adapter and pinouts Figure B‐08. Example of a Digi Radio Modem (DCE node) connecting to another DCE node) NULL Modem Adapter (female-to-female) Part Number: JD3D3-CDN-A (Gray, DB-9 F-F) The female-to-female NULL modem adapter is used to verify serial cabling is functioning properly. To test cables, insert the female-to-female NULL modem adapter in place of a pair of module assemblies (RS-232 interface board + XTend Module) and test the connection without the modules in the connection. Figure B‐09. Female NULL modem adapter and pinouts © 2007 Digi International, Inc. 74 XBee Series 2/XBee Series 2 PRO ZigBee OEM RF Modules v1.x2x Serial Loopback Adapter Part Number: JD2D3-CDL-A (Red, DB-9 M-F) The serial loopback adapter is used for range testing. During a range test, the serial loopback adapter configures the module to function as a repeater by looping serial data back into the radio for retransmission. Figure D‐01. Serial loopback adapter and pinouts USB Development Board External Interface B-11a. I/O & Power LEDs LEDs indicate RF module activity as follows: Figure D‐02. Front View Yellow (top LED) = Serial Data Out (to host) Green (middle) = Serial Data In (from host) Red (bottom) = Power/Association Indicator (Refer to the D5 (DIO5 Configuration) parameter) B‐11b. RSSI LEDs B‐11c. USB Port B-11b. RSSI LEDs B‐11a. I/O & Power LEDs RSSI LEDs indicate the amount of fade margin present in an active wireless link. Fade margin is defined as the difference between the incoming signal strength and the module's receiver sensitivity. LEDs ON LEDs ON LED ON LED ON Very Strong Signal (> 30 dB fade margin) Strong Signal (> 20 dB fade margin) Moderate Signal (> 10 dB fade margin) Weak Signal (< 10 dB fade margin) B-11c. USB Port Standard Type-B OEM connector is used to communicate with OEM host and power the RF module. B-12a. DIP Switch © 2007 Digi International, Inc. 75 XBee Series 2/XBee Series 2 PRO ZigBee OEM RF Modules v1.x2x Figure D‐03. Back View DIP Switch functions are not supported in this release. Future downloadable firmware versions will support the DIP Switch configurations. B-12b. Reset Switch The Reset Switch is used to reset (re-boot) the RF module. B‐12a. Reset Switch B‐12a. DIP Switch © 2007 Digi International, Inc. 76 XBee Series 2/XBee Series 2 PRO ZigBee OEM RF Modules v1.x2x USB Pin Signals Table D‐03. USB signals and their implantations on the XBee Series 2/XBee Series 2 PRO RF Module Pin Name Description Implementation VBUS Power Power the RF module D- Transmitted & Received Data Transmit data to and from the RF module D+ Transmitted & Received Data Transmit data to and from the RF module GND Ground Signal Ground X-CTU Software X-CTU is a Digi-provided software program used to interface with and configure Digi RF Modules. The software application is organized into the following four tabs: • PC Settings tab - Setup PC serial ports for interfacing with an RF module • Range Test tab - Test the RF module's range and monitor packets sent and received • Terminal tab - Set and read RF module parameters using AT Commands • Modem Configuration tab - Set and read RF module parameters Figure D‐04. X‐CTU User Interface (PC Settings, Range Test, Terminal and Modem Configuration tabs) NOTE: PC Setting values are visible at the bottom of the Range Test, Terminal and Modem Configuration tabs. A shortcut for editing PC Setting values is available by clicking on any of the values. Install Double-click the "setup_X-CTU.exe" file and follow prompts of the installation screens. Setup To use the X-CTU software, a module assembly (An RF module mounted to an interface Board) must be connected to a serial port of a PC. The interface data rate and parity settings of the serial port ("PC Settings" tab) must match those of the module (BD (Baud Rate) and NB (Parity) parameters). Serial Communications Software A terminal program is built into the X-CTU Software. Other terminal programs such as "HyperTerminal" can also be used. When issuing AT Commands through a terminal program interface, use the following syntax: Figure D‐05. Syntax for sending AT Commands NOTE: To read a parameter value stored in a register, leave the parameter field blank. © 2007 Digi International, Inc. 77 XBee Series 2/XBee Series 2 PRO ZigBee OEM RF Modules v1.x2x The example above issues the DL (Destination Address Low) command to change destination address of the module to "0x1F". To save the new value to the module’s non-volatile memory, issue WR (Write) command after modifying parameters. © 2007 Digi International, Inc. 78 Appendix E: Additional Information 1-Year Warranty XBee Series 2 RF Modules from Digi, Inc. (the "Product") are warranted against defects in materials and workmanship under normal use, for a period of 1-year from the date of purchase. In the event of a product failure due to materials or workmanship, Digi will repair or replace the defective product. For warranty service, return the defective product to MaxStream, shipping prepaid, for prompt repair or replacement. The foregoing sets forth the full extent of MaxStream's warranties regarding the Product. Repair or replacement at MaxStream's option is the exclusive remedy. THIS WARRANTY IS GIVEN IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, AND DIGI SPECIFICALLY DISCLAIMS ALL WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL DIGI, ITS SUPPLIERS OR LICENSORS BE LIABLE FOR DAMAGES IN EXCESS OF THE PURCHASE PRICE OF THE PRODUCT, FOR ANY LOSS OF USE, LOSS OF TIME, INCONVENIENCE, COMMERCIAL LOSS, LOST PROFITS OR SAVINGS, OR OTHER INCIDENTAL, SPECIAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OR INABILITY TO USE THE PRODUCT, TO THE FULL EXTENT SUCH MAY BE DISCLAIMED BY LAW. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES. THEREFORE, THE FOREGOING EXCLUSIONS MAY NOT APPLY IN ALL CASES. This warranty provides specific legal rights. Other rights which vary from state to state may also apply. Ordering Information Figure E‐01. Divisions of the XBee Series 2 RF Module Part Numbersʺ Antenna Types S = RPSMA W = Wire Antenna C = Chip Antenna U = U.FL Connector Firmware versions 1 = Coordinator; API Operation 2 = Coordinator; Transparent Operation 3 = Router/End Device; API Operation 4 = Router/End Device, Transparent Operation Contact Digi Free and unlimited technical support is included with every Digi Radio Modem sold. For the best in wireless data solutions and support, please use the following resources: Technical Support: Phone. (866) 765-9885 toll-free U.S.A. & Canada (801) 765-9885 Worldwide Live Chat. www.digi.com E-Mail. support@digi.com Digi’s office hours are 8:00 am - 5:00 pm [U.S. Central Standard Time] © 2007 Digi International, Inc. 79
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Tagged PDF : Yes Page Mode : UseOutlines XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Format : application/pdf Creator : reckery Title : product-manual_xb_zigbee_oem_rf-modules_v1.x1x.book Create Date : 2007:10:31 13:04:17Z Creator Tool : FrameMaker 7.2 Modify Date : 2007:11:01 09:15:50-04:00 Metadata Date : 2007:11:01 09:15:50-04:00 Producer : Acrobat Distiller 8.0.0 (Windows) Document ID : uuid:3ca72c49-131e-4583-9882-78d587b6da6a Instance ID : uuid:34dcd1ce-3d90-419f-8b82-773d55e8c9b3 Page Count : 79 Author : reckeryEXIF Metadata provided by EXIF.tools