Digi XBPS2C XBee-PRO ZB module User Manual XBee XBee PRO SMT ZB RF Modules

Digi International Inc XBee-PRO ZB module XBee XBee PRO SMT ZB RF Modules

User Manual

XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 1  XBee®/XBee-PRO® SMT ZB RF Modules  This manual describes the operation of the XBee® /XBee-PRO® SMT ZB RF module, which consists of ZigBee firmware loaded onto XBee® S2C and S2C PRO hardware.  The XBee® /XBee-PRO® SMT ZB RF Modules are designed to operate within the ZigBee protocol and support the unique needs of low-cost, low-power wireless sensor networks. The modules require minimal power and provide reliable delivery of data between remote devices.   The modules operate within the ISM 2.4 GHz frequency band.                       Digi International Inc.  11001 Bren Road East  Minnetonka, MN 55343 877 912-3444 or 952 912-3444
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 2  http://www.digi.com  © 2010 Digi International, Inc. All rights reserved  No part of the contents of this manual may be transmitted or reproduced in any form or by any means without the written permission of Digi International, Inc.  ZigBee® is a registered trademark of the ZigBee Alliance.  XBee® and XBee Technical Support:   Phone:     (866) 765-9885 toll-free U.S.A. & Canada (801) 765-9885 Worldwide  8:00 am - 5:00 pm [U.S. Mountain Time]  Live Chat:   www.digi.com  Online Support:   http://www.digi.com/support/eservice/login.jsp  Email:     rf-experts@digi.com
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 3  Contents 1. Overview ............................................................................................................................................. 13 Specifications .......................................................................................................................................... 13 General Specifications ......................................................................................................................... 13 RF Specifications ................................................................................................................................. 14 Electrical Specifications ....................................................................................................................... 14 Environmental Specifications .............................................................................................................. 15 Serial Communications Specifications ................................................................................................ 15 Network and Security ......................................................................................................................... 16 GPIO Specifications ............................................................................................................................. 16 Agency Approvals ................................................................................................................................ 17 Hardware Specifications for Programmable Variant .......................................................................... 17  ............................................................................................................................................. 17 Firmware ............................................................................................................................................. 17 Manual ................................................................................................................................................ 17 Pin Signals ............................................................................................................................................... 19 EM357 Pin Mappings .............................................................................................................................. 20 Design Notes ........................................................................................................................................... 20 Power Supply ...................................................................................................................................... 20 Recommended Pin Connections ......................................................................................................... 21 Board Layout ....................................................................................................................................... 21 Module Operation for Programmable Variant ................................................................................... 24 XBEE Programmable Bootloader ............................................................................................................ 26 Overview ............................................................................................................................................. 26 Bootloader Software Specifics ............................................................................................................ 26 Bootloader Menu Commands ............................................................................................................. 31 Firmware Updates ............................................................................................................................... 32 Output File Configuration ................................................................................................................... 33 1. RF Module Operation ......................................................................................................................... 34 Serial Communications ........................................................................................................................... 34 UART Communications ....................................................................................................................... 34 SPI Communications ........................................................................................................................... 35
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 4  Serial Buffers ....................................................................................................................................... 36 Serial Flow Control .............................................................................................................................. 37 Serial Interface Protocols .................................................................................................................... 37 Modes of Operation ................................................................................................................................ 40 Idle Mode ............................................................................................................................................ 40 Transmit Mode .................................................................................................................................... 40 Receive Mode ..................................................................................................................................... 41 Command Mode ................................................................................................................................. 41 Sleep Mode ......................................................................................................................................... 43 3. XBee ZigBee Networks ............................................................................................................................ 44 Introduction to ZigBee ............................................................................................................................ 44 ZigBee Stack Layers ................................................................................................................................. 44 Networking concepts .............................................................................................................................. 44 Device Types ....................................................................................................................................... 44 PAN ID ................................................................................................................................................. 45 Operating Channel .............................................................................................................................. 46 ZigBee Application Layers: In Depth ....................................................................................................... 46 Application Support Sublayer (APS) .................................................................................................... 46 Application Profiles ............................................................................................................................. 46 Clusters................................................................................................................................................ 47 Endpoints ............................................................................................................................................ 47 ZigBee Device Profile .......................................................................................................................... 48 ZigBee Device Objects (ZDO) ............................................................................................................... 48 Coordinator Operation............................................................................................................................ 48 Forming a Network ............................................................................................................................. 48 Channel Selection................................................................................................................................ 48 PAN ID Selection ................................................................................................................................. 48 Security Policy ..................................................................................................................................... 48 Persistent Data .................................................................................................................................... 48 XBee ZB Coordinator Startup .................................................................................................................. 49 Permit Joining ..................................................................................................................................... 50 Resetting the Coordinator .................................................................................................................. 50
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 5  Leaving a Network .............................................................................................................................. 50 Replacing a Coordinator (Security Disabled Only) .............................................................................. 51 Example: Starting a Coordinator ......................................................................................................... 51 Example: Replacing a Coordinator (security disabled) ....................................................................... 52 Router Operation ................................................................................................................................... 52 Discovering ZigBee Networks ............................................................................................................ 52 Joining a Network ............................................................................................................................... 52 Authentication .................................................................................................................................... 53 Persistent Data ................................................................................................................................... 53 XBee ZB Router Joining ...................................................................................................................... 53 Permit Joining ..................................................................................................................................... 54 Joining Always Enabled ...................................................................................................................... 54 Joining Temporarily Enabled .............................................................................................................. 54 Router Network Connectivity ............................................................................................................ 54 Leaving a Network .............................................................................................................................. 56 Resetting the Router .......................................................................................................................... 57 Example:  Joining a Network .............................................................................................................. 57 End Device Operation ............................................................................................................................ 57 Discovering ZigBee Networks ............................................................................................................ 57 Joining a Network ............................................................................................................................... 58 Parent Child Relationship ................................................................................................................... 58 End Device Capacity ........................................................................................................................... 58 Authentication .................................................................................................................................... 58 Persistent Data ................................................................................................................................... 58 Orphan Scans ...................................................................................................................................... 58 XBee: ZB End Device Joining .............................................................................................................. 58 Parent Connectivity ............................................................................................................................ 59 Resetting the End Device ................................................................................................................... 60 Leaving a Network .............................................................................................................................. 60 Example: Joining a Network ............................................................................................................... 60 Channel Scanning ................................................................................................................................... 61 Managing Multiple ZigBee Networks .................................................................................................... 61
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 6  Pan ID Filtering ....................................................................................................................................... 61 Preconfigured Security Keys .............................................................................................................. 61 Permit Joining ..................................................................................................................................... 61 Application Messaging ....................................................................................................................... 61 4. Transmission, Addressing, and Routing ................................................................................................ 63 Addressing .............................................................................................................................................. 63 64-bit device Address ......................................................................................................................... 63 16-bit Device Address ......................................................................................................................... 63 Application Layer Addressing ............................................................................................................ 63 Data Transmission .............................................................................................................................. 63 Broadcast Transmissions .................................................................................................................... 63 Unicast Transmissions ........................................................................................................................ 64 DATA Transmission Examples ............................................................................................................ 66 RF Packet Routing ................................................................................................................................... 67 Link Status Transmission ........................................................................................................................ 68 AODV Mesh Routing............................................................................................................................... 69 Many-to-One Routing ............................................................................................................................ 71 Source Routing ....................................................................................................................................... 72 Acquiring Source Routes .................................................................................................................... 73 Storing Source Routes ............................................................................................................................ 73 Sending a Source Routed Transmission ............................................................................................. 73 Repairing Source Routes .................................................................................................................... 74 Retries and Acknowledgments .......................................................................................................... 74 Encrypted Transmissions ....................................................................................................................... 75 Maximum RF Payload Size ..................................................................................................................... 75 Throughput ............................................................................................................................................. 75 ZDO Transmissions ................................................................................................................................. 76 ZigBee Device Objects (ZDO) .............................................................................................................. 76 Sending a ZDO Command................................................................................................................... 77 Receiving ZDO Commands and Responses ........................................................................................ 77 Transmission Timeouts .......................................................................................................................... 78 Unicast Timeout ................................................................................................................................. 79
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 7  Extended Timeout .............................................................................................................................. 79 Transmission Examples ...................................................................................................................... 80 5. Security ............................................................................................................................................... 82 Security Modes ....................................................................................................................................... 82 ZigBee Security Model ........................................................................................................................... 82 Network Layer Security ...................................................................................................................... 82 Frame Counter .................................................................................................................................... 83 Message Integrity code ...................................................................................................................... 83 Network Layer Encryption and Decryption ....................................................................................... 83 Network Key Updates ........................................................................................................................ 83 APS Layer Security .............................................................................................................................. 83 Message Integrity Code ...................................................................................................................... 84 APS Link Keys ...................................................................................................................................... 84 APS Layer Encryption and Decryption ............................................................................................... 84 Network and APS Layer Encryption ................................................................................................... 84 Trust Center ........................................................................................................................................ 85 Forming and Joining a secure Network ............................................................................................. 85 Implementing Security on the XBee ...................................................................................................... 85 Enabling Security ................................................................................................................................ 85 Setting the Network Security Key ...................................................................................................... 86 Setting the APS Trust Center Link Key ............................................................................................... 86 Enabling APS Encryption .................................................................................................................... 86 Using a Trust Center ........................................................................................................................... 86 XBee Security Examples ......................................................................................................................... 87 Example 1: Forming a network with security (pre-configured link keys) ......................................... 87 Example 1: Forming a network with security (obtaining keys during joining) ................................ 87 6. Network Commissioning and Diagnostics ......................................................................................... 89 Device Configuration .............................................................................................................................. 89 Device Placement ................................................................................................................................... 89 Link Testing ......................................................................................................................................... 89 RSSI Indicators .................................................................................................................................... 90 Device Discovery .................................................................................................................................... 90
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 8  Network Discovery ............................................................................................................................. 90 ZDO Discovery .................................................................................................................................... 90 Joining Announce ............................................................................................................................... 90 Commissioning Pushbutton and Associate LED .................................................................................... 90 Commissioning Pushbutton ............................................................................................................... 91 Associate LDE ...................................................................................................................................... 91 7. Managing End Devices ....................................................................................................................... 94 End Device Operation ............................................................................................................................ 94 Parent Operation .................................................................................................................................... 94 End Device Poll Timeouts ................................................................................................................... 95 Packet Buffer Usage ........................................................................................................................... 95 Non-Parent Device Operation ................................................................................................................ 95 XBee End Device Configuration ............................................................................................................. 96 Pin Sleep ............................................................................................................................................. 96 Cyclic Sleep ......................................................................................................................................... 98 Transmitting RF Data ........................................................................................................................ 101 Receiving RF Data ............................................................................................................................. 101 IO Sampling ....................................................................................................................................... 102 Waking End Devices with the Commissioning Pushbutton ............................................................ 102 Parent Verification ........................................................................................................................... 102 Rejoining ........................................................................................................................................... 102 XBee Router/Coordinator Configuration ............................................................................................ 102 RF Packet Buffering Timeout ........................................................................................................... 103 Child Poll Timeout ............................................................................................................................ 103 Transmission Timeout ...................................................................................................................... 103 Putting it all Together .......................................................................................................................... 103 Short Sleep Periods .......................................................................................................................... 103 Extended Sleep Periods .................................................................................................................... 104 Sleep Examples ..................................................................................................................................... 104 Configure a device to sleep for 20 seconds, but set SN such that the On/Sleep line will remain deasserted for up to 1 minute. ........................................................................................................ 104
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 9  Configure an end device to sleep for 20 seconds, send 4 IO samples in 2 seconds, and return to sleep. ................................................................................................................................................. 104 Configure a device for extended sleep: to sleep for 4 minutes. ..................................................... 105 8. XBee Analog and Digital IO Lines ..................................................................................................... 106 IO Configuration ................................................................................................................................... 106 IO Sampling ........................................................................................................................................... 107 Queried Sampling ............................................................................................................................. 108 Periodic IO Sampling ........................................................................................................................ 109 Change Detection Sampling ............................................................................................................. 109 RSSI PWM ............................................................................................................................................. 109 IO Examples .......................................................................................................................................... 110 Example 1: Configure the following IO settings on the XBee ......................................................... 110 Example 2: Calculate the PWM counts for a packet received with an RSSI of -84dBm. ................ 110 Example 3: Configure the RSSI/PWM pin to operate for 2 seconds after each received RF packet. .......................................................................................................................................................... 110 9. API Operation ................................................................................................................................... 111 API Frame Specifications ...................................................................................................................... 111 API Operation (AP parameter = 1) ................................................................................................... 111 API Operation-with Escape Characters (AP parameter = 2) ........................................................... 111 API Examples .................................................................................................................................... 113 API UART and SPI Exchanges ............................................................................................................... 113 AT Commands ................................................................................................................................... 113 Transmitting and Receiving RF Data ................................................................................................ 114 Remote AT commands ..................................................................................................................... 114 Source Routing ................................................................................................................................. 115 Supporting the API ............................................................................................................................... 115 API Frames ............................................................................................................................................ 116 AT Command .................................................................................................................................... 116 AT Command-Queue Parameter Value ........................................................................................... 116 ZigBee Transmit Request ................................................................................................................. 117 Explicit Addressing ZigBee Command Frame .................................................................................. 119 Remote AT Command Request ........................................................................................................ 121
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 10  Create Source Route ......................................................................................................................... 121 AT Command Response ................................................................................................................... 123 Modem Status .................................................................................................................................. 123 ZigBee Transmit Status ..................................................................................................................... 124 ZigBee Receive Packet ...................................................................................................................... 125 ZigBee Explicit RX Indicator ............................................................................................................. 126 ZigBee IO Data Sample RX Indicator ................................................................................................ 127 XBee Sensor Read Indicator ............................................................................................................. 128 Node Identification Indicator ........................................................................................................... 130 Remote Command Response ........................................................................................................... 131 Over-the-Air Firmware Update Status ............................................................................................. 132 Route Record Indicator .................................................................................................................... 133 Many-to-One Route Request Indicator ........................................................................................... 134 Sending ZigBee device objects (ZDO) Commands with the API ...................................................... 135 Sending ZigBee Cluster Library (ZCL) Commands with the API ....................................................... 137 Sending Public Profile Commands with the API .............................................................................. 140 10. XBee Command Reference Tables ............................................................................................... 143 Addressing ............................................................................................................................................ 143 Networking ........................................................................................................................................... 144 Security ................................................................................................................................................. 146 RF Interfacing ........................................................................................................................................ 147 Serial Interfacing .................................................................................................................................. 148 Serial Interfacing .................................................................................................................................. 149 Diagnostics Interfacing ......................................................................................................................... 152 AT Command Options .......................................................................................................................... 153 Sleep Commands .................................................................................................................................. 153 Execution Commands ........................................................................................................................... 154 11. Module Support ........................................................................................................................... 156 X-CTU Configuration Tool ..................................................................................................................... 156 Customizing XBee ZB Firmware ........................................................................................................... 156 Design Considerations for Digi Drop-In Networking ........................................................................... 156 XBee Bootloader................................................................................................................................... 156
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 11  Programming XBee Modules ............................................................................................................... 157 Serial Firmware Updates .................................................................................................................. 157 Invoke XBee Bootloader................................................................................................................... 157 Send Firmware Image....................................................................................................................... 157 Writing Custom Firmware .................................................................................................................... 158 Regulatory Compliance .................................................................................................................... 158 Configuring GPIOs ............................................................................................................................ 159 Detecting XBee vs. XBee-PRO .......................................................................................................... 159 12. Agency Certifications .................................................................................................................... 160 United States FCC ................................................................................................................................. 160 OEM Labeling Requirements ........................................................................................................... 160 FCC Notices ....................................................................................................................................... 160 FCC-Approved Antennas (2.4 GHz) .................................................................................................. 161 RF Exposure ...................................................................................................................................... 166 Europe (ETSI) ........................................................................................................................................ 167 OEM Labeling Requirements ........................................................................................................... 167 Restrictions ....................................................................................................................................... 167 Declarations of Conformity .............................................................................................................. 168 Approved Antennas.......................................................................................................................... 168 XBee RF Module ............................................................................................................................... 168 Canada (IC) ............................................................................................................................................ 170 Transmitters with Detachable Antennas ......................................................................................... 170 Detachable Antenna ......................................................................................................................... 170 Australia (C-Tick) .................................................................................................................................. 170 13. Migrating from XBee S2B to XBee S2C ........................................................................................ 171 Pin Mapping .......................................................................................................................................... 171 Mounting .............................................................................................................................................. 171 14. Manufacturing Information ......................................................................................................... 173 Recommended Solder Reflow Cycle .................................................................................................... 173 Recommended Footprint ..................................................................................................................... 174 Flux and Cleaning ................................................................................................................................. 174 Reworking ............................................................................................................................................. 175
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 12  15. Warranty Information .................................................................................................................. 176 1-Year Warranty ................................................................................................................................... 176 Appendix A:  Definitions .......................................................................................................................... 177 Definitions ............................................................................................................................................ 177 ZigBee Node Types ........................................................................................................................... 177 ZigBee Protocol ................................................................................................................................. 178
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 13   1. Overview XBee® and XBee-PRO® S2C SMT ZB embedded RF modules provide wireless connectivity to end-point devices in ZigBee mesh networks. Utilizing the ZigBee PRO Feature Set, these modules are interoperable with other ZigBee devices, including devices from other vendors. With XBee, users can have their ZigBee network up-and-running in a matter of minutes without configuration or additional development. The programmable XBee® and XBee-PRO® S2C SMT ZB modules incorporate a Freescale SO8 microprocessor for customization and application development. XBee® and XBee-PRO® ZB Modules are compatible with other devices that use XBee® ZB" technology. These include ConnectPort X gateways, XBee® and XBee-PRO® Adapters, XBee Wall Routers, XBee Sensors, and other products when designated with the "ZB" product name. Devices that do not have the "ZB" product name, including Digi's line of DigiMesh and 802.15.4 XBee products, are not compatible with XBee® and XBee-PRO® ZB Modules.  Network interoperability with ZigBee devices from other vendors requires that the ZigBee Feature Set or ZigBee PRO Feature Set be deployed on all devices. Contact Digi Support for details. Specifications General Specifications Specification XBee (S2C) XBee-PRO (S2C) Performance     Dimensions 0.866 X 1.3" (2.199 X 3.302 cm) Operating Temperature  -40 to 85° C (Industrial) Antenna Options RF Pad, PCB Antenna, or U.FL Connector
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 14  RF Specifications Specification XBee ®  (S2C) XBee-PRO® (S2C) Performance     Frequency ISM 2.4-2.5GHz Number of Channels 16 Direct Sequence Channels 15 Direct Sequence Channels Channels 11 to 26 11 to 25 Adjustable Power Yes Interface immunity DSSS (Direct Sequence Spread Spectrum) Indoor/Urban Range 200 ft  300 ft  Outdoor RF line-of-sight Range up to 4000 ft (1200m) Up to 2 miles (3220 m)  Transmit Power Output 6.3mW (8dBm) Boost mode, 2mW (3dBm) Normal mode  Channel 26 max power is 3dBm  63mW (18dBm) typical, adjustable down to 0dBm   RF Data Rate 250,000 bps Receiver Sensitivity  -102dBm, Boost mode                      -100dBm, Normal mode -101dBm, Boost mode 99dBm, Normal mode   Electrical Specifications Specification XBee® (S2C) XBee-PRO® (S2C) Performance     Supply Voltage 2.1 - 3.6 V 2.2  3.6V for Programmable Version 2.7 -3.6V  Operating Current                           (Transmit) 45mA @3.3V, 8dBm (Boost mode)                                         33mA @3.3V, 3dBm (Normal mode) 100mA typical @3.3V, 18dBm Operating Current                           (Receive) 31mA @3.3V (Boost mode)                                                                                 28mA @3.3V (Normal mode) 31mA @3.3V Idle Current (Receiver off) 9mA 9mA  Power-down Current <1uA @25C <1uA @ 25C
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 15  Environmental Specifications Specification XBee (S2C) XBee-PRO (S2C) Performance     ESD 3000 V HBM 4000 V HBM  MSL 3 3  ROHS Compliant  Serial Communications Specifications The XBee® /XBee-PRO® SMT ZB RF modules support both UART (Universal Asynchronous Receiver/Transmitter) and SPI (Serial Peripheral Interface, in master or slave mode) serial connections.  UART The SC1 (Serial Communication Port 1) of the Ember 357 is connected to the UART port. UART Pin Assignments Specification XBee (S2C) XBee-PRO (S2C) UART Pins Module Pin Number DOUT 3 DIN/nCONFIG 4 nCTS/DIO7 25 nRTS/DIO6 29  More information on UART operation is found in the UART section in chapter 2 SPI The SC2 (Serial Communication Port 2) of the Ember 357 is connected to the SPI port. SPI Pin Assignments Specification XBee (S2C) XBee-PRO (S2C) SPI Pins Module Pin Number SPI_SCLK/DIO18 14 SPI_nSSEL/DIO17 15 SPI_MOSI/DIO16 16 SPI_MISO/DIO15 17  For more information on SPI operation see the SPI section in chapter 2
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 16  Network and Security Specification XBee (S2C) XBee-PRO (S2C) Performance     Supported Network Topologies Point-to-point, Point-to-multipoint, Peer-to-peer, and Mesh Addressing Options PAN ID and Addresses, Cluster IDs and Endpoints (optional)  GPIO Specifications The XBee® /XBee-PRO® SMT ZB RF modules have 16 GPIO (General Purpose Input Output) ports available.  Those available will depend on the module configuration as some GPIO pads are consumed by serial communication, etc. See GPIO section for more information on configuring and using GPIO ports Electrical Specification for GPIO pads Specification XBee (S2C) XBee-PRO (S2C) Performance Module Pin Number Voltage Supply 2.1 to 3.6V Low Schmitt switching threshold 0.42 to 0.5 X VCC High Schmitt switching threshold 0.62 to 0.8 X VCC Input current for logic 0  -0.5uA Input current for logic 1 0.5uA Input pull-up resistor value  Input pull-down resistor value  Output voltage for logic 0 0.18 X VCC (Max) Output voltage for logic 1 0.82 X VCC (Min) Output source current for pad numbers 3, 4, 5, 10, 12, 14, 16, 17, 26, 28, 29, 30,  and 32 4mA Output sink current for pad numbers 3, 4, 5, 10, 12, 14, 16, 17, 26, 28, 29, 30,  and 33 4mA Output source current for pad numbers 7,8,24,31, and 33 8mA Output sink current for pad numbers 7,8,24,31, and 34 8mA Total output current (for I/O Pads) 40mA
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 17  Agency Approvals Specification XBee (S2C) XBee-PRO (S2C) Performance     United States (FCC Part 15.247) FCC ID: MCQ-XBS2C FCC ID: MCQ-XBPS2C  Industry Canada (IC) IC: 1846A-XBS2C IC: 1846A-XBPS2C Europe (DC) ETSI  Australia C-Tick C-Tick Japan Pending     FCC Approval (USA) Refer to Chapter 12 FCC Requirements. Systems that contain XBee®/ XBee-PRO® ZB RF Modules inherit Digi Certifications. Hardware Specifications for Programmable Variant The following specifications need to be added to the current measurement of the previous table if the module has the programmable secondary processor. For example, if the secondary processor is running and constantly collecting DIO samples at a rate while having the RF portion of the XBEE sleeping the new current will be I total = Ir2 + Is. Where Ir2 is the runtime current of the secondary processor and is the sleep current of the RF portion of the module of the XBEE-PRO (S2B) listed in the table below. Specifications of the programmable secondary processor   Optional Secondary Processor Specification These numbers add to S2C specifications (Add to RX, TX and Sleep currents depending on mode of operation) Runtime current for 32K running at 20MHz  +14mA Runtime current for 32K running at 1MHz  +1mA Sleep current  +0.5uA typical For additional Specifications see Freescale Datasheet and Manual  MC9S08QE32 Minimum Reset low pulse time for EM357 +26uS  VREF Range 1.8VDC to VCC   What’s New Firmware Manual
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 18
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 19  Pin Signals Pin Assignments for the XBee S2C and XBee S2C Pro modules  lower case n before the signal name.) Pin # Name Direction Default State Description 1 GND  -  - Ground 2 VCC  -  - Power Supply 3 DOUT/DIO13 Both Output Uart Data out/GPIO 4 Din/nConfig/DIO14 Both Input Uart Data In/GPIO 5 DIO12 Both   GPIO 6 nRESET Both   Module Reset 7 RSSI PWM/ DIO10 Both   RX Signal Strength Indicator/ GPIO 8 PWM1/DIO11 Both   Pulse Width Modulator/GPIO 9 reserved  -  Disabled Do Not Connect 10 nDTR/SLEEP_RQ/DIO8 Both Input Pin Sleep Control line /GPIO 11 GND  -  - Ground 12 SPI_Attn/nBOOTMODE/DIO19 Output Output Serial Peripheral Interface Attention                 Do not tie low on reset 13 GND  -  - Ground 14 SPI_CLK/DIO18 Both   Serial Peripheral Interface Clock/GPIO 15 SPI_nSSEL/DIO17 Both   Serial Peripheral Interface not Select/GPIO 16 SPI_MOSI/DOI16 Both   Serial Peripheral Interface Data Input/GPIO 17 SPI_MOSO/DOI15 Both   Serial Peripheral Interface Data Output/GPIO 18 JTCK/SWCLK Input   JTAG Clock/Serial Wire Clock 19 JTDO/SWO Output   JTAG Data Output/Serial Wire Data Output 20 JTDI Input   JTAG Data Input 21 JTMS/SWDIO Both     22 GND  -  - Ground 23 reserved  -  Disabled Do Not Connect 24 DIO4 Both   GPIO 25 nCTS/DIO7 Both Output Clear-to-Send Flow Control/GPIO 26 On /SLEEP/DIO9 Output Output Module Status Indicator/GPIO 27 VREF Input  - Not used for EM357. Used for programmable secondary processor. For compatibility with other XBEE modules, we recommend connecting this pin to the voltage reference if Analog sampling is desired. Otherwise, connect to GND. 28 Associate/DIO5 Both Output Associate Indicator/GPIO 29 nRTS/DIO6/SCLK2 Both Input Request-to-Send Flow Control/GPIO 30 AD3/DIO3 Both   Analog Input/GPIO 31 AD2/DIO2 Both   Analog Input/GPIO 32 AD0/DIO0 Both   Analog Input/GPIO 33 AD1/DIO1 Both   Analog Input/GPIO 34 reserved  -  Disabled Do Not Connect 35 GND  -  - Ground 36 RF Both  - RF IO for RF Pad Variant 37 reserved  -  Disabled Do Not Connect
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 20  EM357 Pin Mappings The Following table shows how the EM357 pins are used on the XBee. EM357 Pin # EM357 Name XBee Pin # Other Usage 12 nRst 6 Programming 18 GPIO PB3 8   19 GPIO PA7 29   20 GPIO PB4 25   21 GPIO PA0/SC2MOSI 16   22 GPIO PA1/SC2MOSO 17   24 GPIO PA2/SC2SCLK 14   25 GPIO PA3/SC2nSSEL 15   26 GPIO PA4 32 Programming 27 GPIO PA5/nBOOTMODE 12 Programming 29 GPIO PA6 7   30 GPIO PB1 3   31 GPIO PB2 4   32 SWCLK,JTCK 18 Programming 33 GPIO PC2/JTDO/SWO 19 Programming 34 GPIO PC3/JTDI 20 Programming 35 GPIO PC4/JTMS/SWDIO 21 Programming 36 GPIO PB0 10   38 GPIO PC1 30   41 GPIO PB7,ADC2 31   42 GPIO PB6,ADC1 33   43 GPIO PB5,ADC0   Temp Sensor on PRO Version NOTE:  Some lines may not go to the external XBEE pads in the programmable secondary processor version   Design Notes The XBee modules do not specifically require any external circuitry or specific connections for proper operation. However, there are some general design guidelines that are recommended for help in troubleshooting and building a robust design. Power Supply Poor power supply can lead to poor radio performance especially if the supply voltage is not kept within tolerance or is excessively noisy. To help reduce noise a 1uF and 8.2pF capacitor are recommended to be placed as near to pin 2 on the PCB as possible. If using a switching regulator for your power supply, switching frequencies above 500 kHz are preferred. Power supply ripple should be limited to a maximum 250mV peak to peak.
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 21  Note  For designs using the programmable modules an additional 10uF decoupling cap is recommended near pin 2 of the module. The nearest proximity to pin 2 of the 3 caps should be in the following order: 8.2pf, 1uF followed by 10uF. Recommended Pin Connections The only required pin connections are VCC, GND, DOUT and DIN. To support serial firmware updates, VCC, GND, DOUT, DIN, RTS, and DTR should be connected.  All unused pins should be left disconnected. All inputs on the radio can be pulled high with 30k internal pull-up resistors using the PR software command. No specific treatment is needed for unused outputs.  For applications that need to ensure the lowest sleep current, inputs should never be left floating. Use internal or external pull-up or pull-down resistors, or set the unused I/O lines to outputs.  Other pins may be connected to external circuitry for convenience of operation including the Associate LED pad (pad 28) and the Commissioning pad (pad 33). The Associate LED pin will flash differently depending on the state of the module to the network, and a pushbutton attached to pad 33 can enable various join functions without having to send UART commands. Please see the commissioning pushbutton and associate LED section in chapter 7 for more details. The source and sink capabilities are limited to 4mA for pad numbers 3, 4, 5, 10, 12, 14, 15, 16, 17, 25, 26, 28, 29, 30, and 32, and 8mA for pad numbers 7, 8, 24, 31, and 33 on the module.  The VREF pin (pad 27) is only used on the programmable versions of these modules.  For compatibility with other XBee modules, we recommend connecting this pin to a voltage reference if analog sampling is desired. Otherwise, connect to GND. Board Layout XBee modules do not have any specific sensitivity to nearby processors, crystals or other PCB components. Other than mechanical considerations, no special PCB placement is required for integrating XBee radios except for those with integral antennas. In general, Power and GND traces should be thicker than signal traces and be able to comfortably support the maximum currents.  The radios are also designed to be self sufficient and work with the integrated and external antennas without the need for additional ground planes on the host PCB. However, considerations should be taken on the choice of antenna and antenna location. Metal objects that are near an antenna cause reflections and may reduce the ability for an antenna to efficiently radiate. Using an integral antenna in an enclosed metal box will greatly reduce the range of a radio. For this type of application an external antenna would be a better choice.  External antennas should be positioned away from metal objects as much as possible. Metal objects next to the antenna or between transmitting and receiving antennas can often block or reduce the transmission distance. Some objects that are often overlooked are metal poles, metal studs or beams in structures, concrete (it is usually reinforced with metal rods), metal enclosures, vehicles, elevators, ventilation ducts, refrigerators and microwave ovens.  Antennas should reside above or away from any metal objects like batteries, tall electrolytic capacitors or metal enclosures.   Antenna elements radiate perpendicular to the direction they point. Thus a vertical antenna emits across the horizon.
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 22  PCB Antennas should not have any ground planes or metal objects above or below the module at the antenna location. For best results the module should be in a plastic enclosure, instead of metal one. It should be placed at the edge of the PCB to which it is mounted. The ground, power and signal planes should be vacant immediately below the antenna section (See drawing for recommended keep out area).
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 23
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 24   Module Operation for Programmable Variant The S2C modules with the programmable option have a secondary processor with 32k of flash and 2k of RAM. This allows module integrators to put custom code on the XBEE module to fit their own unique needs. The DIN, DOUT, RTS, CTS, and RESET lines are intercepted by the secondary processor to allow it to be in control of the data transmitted and received. All other lines are in parallel and can be controlled by either the EM357 or the MC9SO8QE micro (see Block Diagram for details). The EM357 by default has control of certain lines. These lines can be released by the EM357 by sending the proper command(s) to disable the desired DIO line(s) (see XBEE Command Reference Tables).  In order for the secondary processor to sample with ADCs, the XBEE pin 27 (VREF) needs to be connected to a reference voltage.  Digi provides a bootloader that can take care of programming the processor over the air or through the serial interface. This means that over the air updates can be supported through an XMODEM protocol. The processor can also be programmed and debugged through a one wire interface BKGD (Pin 9).
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 25
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 26  XBEE Programmable Bootloader Overview The XBee Programmable module is equipped with a Freescale MC9S08QExx application processor. This application processor comes with a supplied bootloader. The following section describes how to interface the customer's application code running on this processor to the XBee Programmable module's supplied bootloader. This section discusses how to initiate firmware updates using the supplied bootloader for wired and over-the-air updates. Bootloader Software Specifics  Memory Layout Figure 1 shows the memory map for the MC9S08QE32 application processor.  The supplied bootloader occupies the bottom pages of the flash from 0xF200 to 0xFFFF. Application code cannot write to this space.  The application code can exist in Flash from address 0x8400 to 0xF1BC. 1k of Flash from 0x8000 to 0x83FF is reserved for Non Volatile Application Data that will not be erased by the bootloader during a flash update.  A portion of RAM is accessible by both the application and the bootloader. Specifically, there is a shared data region used by both the application and the bootloader that is located at RAM address 0x200 to 0x215. Application code should not write anything to AppResetCause or BLResetCause unless informing the bootloader of the impending reset reason.
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 27
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 28   Operation Upon reset of any kind, the execution control begins with the bootloader.  If the reset cause is Power-On reset (POR), Pin reset (PIN), or Low Voltage Detect(LVD) reset the bootloader will not jump to the application code if the override bits are set to RTS(D7)=1, DTR(D5)=0, and DIN(B0)=0. Otherwise, the bootloader writes the reset cause "NOTHING" to the shared data region, and jumps to the Application.  Reset causes are defined in the file common. h in an enumeration with the following definitions:  typedef enum {  BL_CAUSE_NOTHING = 0x0000, //PIN, LVD, POR  BL_CAUSE_NOTHING_COUNT = 0x0001,//BL_Reset_Cause counter  // Bootloader increments cause every reset  BL_CAUSE_BAD_APP = 0x0010,//Bootloader considers APP invalid  } BL_RESET_CAUSES; typedef enum { APP_CAUSE_NOTHING = 0x0000, APP_CAUSE_USE001 = 0x0001, // 0x0000 to 0x00FF are considered valid for APP use. APP_CAUSE_USE255 = 0x00FF, APP_CAUSE_FIRMWARE_UPDATE = 0x5981, APP_CAUSE_BYPASS_MODE = 0x4682,  APP_CAUSE_BOOTLOADER_MENU = 0x6A18, } APP_RESET_CAUSES; Otherwise, if the reset cause is a "watchdog" or other reset, the bootloader checks the shared memory region for the APP_RESET_CAUSE. If the reset cause is: 1. verifies that it is still less than BL_CAUSE_BAD_APP, and jumps back to the application. If the Application does not clear the BL_RESET_CAUSE, it can prevent an infinite loop of running a bad application that continues to perform illegal instructions or watchdog resets. 2. "APP_CAUSE_FIRMWARE_UPDATE", the bootloader "over-the-air" from a specific 64 bit address. In this case, the bootloader will attempt to initiate an Xmodem transfer from the 64 bit address located in Shared RAM.  3. "APP_CAUSE_BYPASS_MODE", the bootloader UART data directly to the EM250 allowing for direct communication with the EM250.  The only way
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 29  to exit bypass mode is to reset or power cycle the module. If none of the above is true, the bootloader will enter "Command mode". In this mode, users can initiate firmware downloads both wired and over-the-air, check application/bootloader version strings, and enter Bypass mode. If none of the above is true, the bootloader will enter "Command mode". In this mode, users can initiate firmware downloads both wired and over-the-air, check application/bootloader version strings, and enter Bypass mode.  Application Version String Figure 1 shows an "Application version string pointer" area in application flash which holds the pointer to where the application version string resides. The application's linker command file ultimately determines where this string is placed in application flash. It is preferable that the application version string be located at address 0x8400 for MC9S08QE32 parts. The application string can be any characters terminated by the NULL character (0x00). There is not a strict limit on the number of characters in the string, but for practical purposes should be kept under 100 bytes including the terminating NULL character. During an update the bootloader erases the entire application from 0x8400 on. The last page has the vector table specifically the redirected reset vector. The version string pointer and reset vector are used to determine if the application is valid.  Application Interrupt Vector Table and Linker Command File Since the bootloader flash region is read-only, the interrupt vector table is redirected to the region 0xF1C0 to 0xF1FD so that application developers can use hardware interrupts. Note that in order for Application interrupts to function properly, the Application's linker command file (*.prm extension) must be modified appropriately to allow the linker to place the developers code in the correct place in memory.  For example, the developer desires to use the serial communications port SCI1 receive interrupt. The developer would add the following line to the  VECTOR ADDRESS 0x0000F1E0 vSci1Rx This will inform the linker that the interrupt function "vSci1Rx()" should be placed at address 0x0000F1E0. Next, the developer should add a file to their project "vector_table.c" that creates an array of function pointers to the    extern void _Startup(void);/* _Startup located in Start08.c */  extern void vSci1Rx(void);/* sci1 rx isr */  extern short iWriteToSci1(unsigned char *);  void vDummyIsr(void);  #pragma CONST_SEG VECTORS  void (* const vector_table[])(void) = /* Relocated Interrupt vector table */{  vDummyIsr,/* Int.no. 0 Vtpm3ovf (at F1C0)Unassigned */  vDummyIsr, /* Int.no. 1 Vtpm3ch5 (at F1C2) Unassigned */
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 30  vDummyIsr, /* Int.no. 2 Vtpm3ch4 (at F1C4) Unassigned */  vDummyIsr, /* Int.no. 3 Vtpm3ch3 (at F1C6) Unassigned */  vDummyIsr, /* Int.no. 4 Vtpm3ch2 (at F1C8) Unassigned */  vDummyIsr, /* Int.no. 5 Vtpm3ch1 (at F1CA) Unassigned */  vDummyIsr, /* Int.no. 6 Vtpm3ch0 (at F1CC) Unassigned */  vDummyIsr, /* Int.no. 7 Vrtc (at F1CE) Unassigned */  vDummyIsr, /* Int.no. 8 Vsci2tx (at F1D0) Unassigned */  vDummyIsr, /* Int.no. 9 Vsci2rx (at F1D2) Unassigned */  vDummyIsr, /* Int.no. 10 Vsci2err (at F1D4) Unassigned */  vDummyIsr, /* Int.no. 11 Vacmpx (at F1D6) Unassigned */  vDummyIsr, /* Int.no. 12 Vadc (at F1D8) Unassigned */  vDummyIsr, /* Int.no. 13 Vkeyboard (at F1DA) Unassigned */  vDummyIsr, /* Int.no. 14 Viic (at F1DC) Unassigned */  vDummyIsr, /* Int.no. 15 Vsci1tx (at F1DE) Unassigned */  vSci1Rx, /* Int.no. 16 Vsci1rx (at F1E0) SCI1RX */  vDummyIsr, /* Int.no. 17 Vsci1err (at F1E2) Unassigned */  vDummyIsr, /* Int.no. 18 Vspi (at F1E4) Unassigned */  vDummyIsr, /* Int.no. 19 VReserved12 (at F1E6) Unassigned */  vDummyIsr, /* Int.no. 20 Vtpm2ovf (at F1E8) Unassigned */  vDummyIsr, /* Int.no. 21 Vtpm2ch2 (at F1EA) Unassigned */  vDummyIsr, /* Int.no. 22 Vtpm2ch1 (at F1EC) Unassigned */  vDummyIsr, /* Int.no. 23 Vtpm2ch0 (at F1EE) Unassigned */  vDummyIsr, /* Int.no. 24 Vtpm1ovf (at F1F0) Unassigned */  vDummyIsr, /* Int.no. 25 Vtpm1ch2 (at F1F2) Unassigned */  vDummyIsr, /* Int.no. 26 Vtpm1ch1 (at F1F4) Unassigned */  vDummyIsr, /* Int.no. 27 Vtpm1ch0 (at F1F6) Unassigned */ vDummyIsr, /* Int.no. 28 Vlvd (at F1F8) Unassigned */
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 31  vDummyIsr, /* Int.no. 29 Virq (at F1FA) Unassigned */  vDummyIsr, /* Int.no. 30 Vswi (at F1FC) Unassigned */  _Startup /* Int.no. 31 Vreset (at F1FE) Reset vector */  };  void vDummyIsr(void){  for(;;){  if(iWriteToSci1("STUCK IN UNASSIGNED ISR\n\r>"));  }  } The interrupt routines themselves can be defined in separate files. The "vDummyIsr" function is used in conjunction with "iWritetoSci1" for debugging purposes. Bootloader Menu Commands The bootloader accepts commands from both the local UART and OTA. All OTA commands sent must be Unicast with only 1 byte in the payload for each command. A response will be returned to the sender. All Broadcast and multiple byte OTA packets are dropped to help prevent general OTA traffic from being interpreted as a command to the bootloader while in the menu.   Bypass Mode – “B” The bootloader provides a "bypass" mode of operation that essentially connects the SCI1 serial communications peripheral of the Freescale MCU to the EM357's serial Uart channel. This allows direct communication to the EM357 radio for the purpose of firmware and radio configuration changes. Once in bypass mode, the XCTU utility can change modem configuration and/or update EM357 firmware. Bypass mode automatically handles any baud rate up to 115.2kbps. Note that this command is unavailable when module is accessed remotely.   Update Firmware – “F” The "F" command initiates a firmware download for both wired and over-the-air configurations. Depending on the source of the command (received via local UART/SPI, or Over the Air), the download will proceed via wired or over-the-air respectively.   Adjust Timeout for Update Firmware – “T” The "T" command changes the timeout before sending a NAK by Base-Time*2^(T). The Base-Time for the local UART is different than the Base-Time for Over the Air. During a firmware update, the bootloader will automatically increase the Timeout if repeat packets are received or multiple NAKs for the same packet without success occur.   Application Version String – “A” The "A" command provides the version of the currently loaded application. If no application is present, "Unkown" will be returned.
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 32    Bootloader Version String – “V” The "V" command provides the version of the currently loaded bootloader.  The version will return a string in the format BLFFF-HHH-XYZ_DDD where FFF represents the Flash size in kilo bytes, HHH is the hardware, XYZ is the version, and DDD is the preferred XMODEM packet size for updates. Double the preferred packet size is also possible, but not guaranteed. For example "BL032-2B0-023_064" will take 64 byte CRC XMODEM payloads and may take 128 byte CRC XMODEM payloads also. In this case, both 64 and 128 payloads are handled, but the 64 byte payload is preferred for better Over the Air reliability. Firmware Updates Wired Updates  a. Plug XBee programmable module into a suitable serial port on a PC.  b. Open a hyperterminal (or similar dumb terminal application) session with 9600 baud, no parity, and 8 data bits with one stop bit.  c. Hit Enter to display the bootloader menu.  d. Hit the "F" key to initiate a wired firmware update.  e. A series of "C" characters Will be displayed within the hyperterminal window. At this point, select the "transfer->send file" menu item. Select the desired flat binary output file. (The file should start at 0x8400 not 0x0000).  f. Select "Xmodem" as the protocol.  g. Click "Send" on the "Send File" dialog. The file will be downloaded to the XBee Programmable module. Upon a successful update, the bootloader will jump to the newly loaded application. Over-The-Air Updates A user can update their application using the bootloader in an "over-the-air" configuration with the following re assumes that the bootloader is running and not the application. The EM357 baud rate must be set to 9600 baud. The bootloader only operates at 9600 baud. The application must be programmed with some way to support returning to the bootloader in order to support Over the Air (OTA) updates without local intervention.)  a. The XBee module sending the file OTA (Host module) should be set up with a series 2 XBee module with transparent mode firmware.  b. The XBee Programmable module receiving the update (remote module) is configured with API firmware.  c. Open a hyperterminal session to the host module with 9600 baud, no parity, no hardwareflow control, 8 data bits and 1 stop bit.  d. Enter 3 pluses "+++" to place the EM357 in command mode.
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 33  will update (ATDH aabbccdd, ATDL eeffgghh, ATCN, where aabbccddeeffgghh is the hexa-decimal 64 bit address of the target module).  f. Press Enter and the bootloader command menu will be displayed from the remote module. (Note that the option "B" doesn't exist for OTA)  g. Press the "F" key to cause the remote module to request the new firmware file over-the-air.  h. The host module will begin receiving "C" characters indicating that the remote module is requesting an Xmodem CRC transfer. Using XCTU or another terminal program, Select "XMODEM" file transfer. Select the Binary file to upload/transfer. Click Send to start the transfer. At the con-clusion of a successful transfer, the bootloader will jump to the newly loaded application. Output File Configuration BKGD Programming P&E Micro provides a background debug tool that allows flashing applications on the MC9S08QE parts through their background debug mode port. By default, the Codewarrior tool produces an "ABS" output file for use in programming parts through the background debug interface. The programmable XBee from the factory has the BKGD debugging capability disabled. In order to debug, a bootloader with the debug interface enabled needs to be loaded on the secondary processor or a stand-alone app needs to be loaded. Bootloader Updates The supplied bootloader requires files in a "flat binary" format which differs from the default ABS file produced. The Codewarrior tool also produces a S19 output file. In order to successfully flash new applications, the S19 file must be converted into the flat binary format. Utilities are available on the web that will convert S19 output to "BIN" outputs. Often times, the "BIN" file conversion will pad the addresses from 0x0000 to the code space with the same number. (Often 0x00 or 0xFF) These extra bytes before the APP code starts will need to be deleted from the bin file before the file can be transferred to the bootloader.
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 34  1.  RF Module Operation Serial Communications The XBee RF Modules interface to a host device through a logic-level asynchronous serial port, or a Serial Peripheral Interface (SPI) port. Through its serial ports, the module can communicate with any logic and voltage compatible UART or SPI; or through a level translator to any serial device (for example: through a RS-232 or USB interface board).   Two wire serial interface (TWI) is also available, but not supported by Digi.  For information on the TWI see the EM357 specification. UART Communications  UART Data Flow Devices that have a UART interface can connect directly to the pins of the RF module as shown in the figure below.   UART Serial Data Data enters the module UART through the DIN (pin 4) as an asynchronous serial signal. The signal should idle high when no data is being transmitted. Each data byte consists of a start bit (low), 8 data bits (least significant bit first) and a stop bit (high). The following figure illustrates the serial bit pattern of data passing through the module.
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 35  Serial communications depend on the two UARTs (the microcontroller's and the RF module's) to be configured with compatible settings (baud rate, parity, start bits, stop bits, data bits).  The UART baud rate, parity, and stop bits settings on the XBee module can be configured with the BD, NB, and SB commands respectively. See the command table in chapter 10 for details. SPI Communications The XBee modules support SPI communications in the slave mode.  Slave mode receives the clock signal and data from the master and returns data to the master.  The SPI port uses the following signals on the XBee:  SPI_MOSI (Master Out, Slave In)  inputs serial data from the master   SPI_MISO (Master In, Slave Out)  outputs serial data to the master   SPI_SCLK (Serial Clock)  clocks data transfers on MOSI and MISO   SPI_nSSEL (Slave Select)  enables serial communication with the slave   In this mode the following apply:  Data/Clock rates up to 5MBPS are possible.  Data is MSB first  Frame Format mode 0 is used (see below) Frame Format for SPI communications   SPI mode is chip to chip communication.  Digi does not supply SPI communication option of Device Development Evaluation Boards.  SPI Operation When the slave select (SPI_nSSEL) signal is asserted by the master, SPI transmit data is driven to the output pin SPI_MISO, and SPI data is received from the input pin SPI_MOSI. The SPI_nSSEL pin has to be asserted to enable the transmit serializer to drive data to the output signal SPI_MISO. A falling edge on SPI_nSSEL resets the SPI slave shift registers.  If the SPI_SCLK is present, the SPI_MISO line is always driven whether with or without the SPI_nSSEL line driven.  This is a known issue with the Ember EM357 chip, and makes additional hardware necessary if multiple salves are using the same buss with the XBee. If the input buffer is empty, the SPI serializer transmits a busy token (0xFF).
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 36  The SPI slave controller must guarantee that there is time to move new transmit data from the transmit buffer into the hardware serializer. To provide sufficient time, the SPI slave controller inserts a byte of padding at the start of every new string of transmit data. Whenever the transmit buffer is empty and data is placed into the transmit buffer the SPI hardware inserts a byte of padding onto the front of the transmission as if this byte was placed there by software. Serial Buffers The XBee modules maintain small buffers to collect received serial and RF data, which is illustrated in the figure below. The serial receive buffer collects incoming serial characters and holds them until they can be processed. The serial transmit buffer collects data that is received via the RF link that will be transmitted out the UART or SPI port.  Serial Receive Buffer When serial data enters the RF module through the DIN Pin (pin 4), the data is stored in the serial receive buffer until it can be processed. Under certain conditions, the module may not be able to process data in the serial receive buffer immediately. If large amounts of serial data are sent to the module, CTS flow control may be required to avoid overflowing the serial receive buffer.  Cases in which the serial receive buffer may become full and possibly overflow:  1. If the module is receiving a continuous stream of RF data, the data in the serial receive buffer will not be transmitted until the module is no longer receiving RF data.  2. If the module is transmitting an RF data packet, the module may need to discover the destination address or establish a route to the destination. After transmitting the data, the module may need to retransmit the data if an acknowledgment is not received, or if the transmission is a broad-cast. These issues could delay the processing of data in the serial receive buffer. Serial Transmit Buffer When RF data is received, the data is moved into the serial transmit buffer and sent out the UART or SPI port. If the serial transmit buffer, the entire RF data packet is dropped.
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 37  Cases in which the serial transmit buffer may become full resulting in dropped RF packets  1. If the RF data rate is set higher than the interface data rate of the module, the module could receive data faster than it can send the data to the host.  2. If the host does not allow the module to transmit data out from the serial transmit buffer because of being held off by hardware flow control. Serial Flow Control The nRTS and nCTS module pins can be used to provide RTS and/or CTS flow control. CTS flow control provides an indication to the host to stop sending serial data to the module. RTS flow control allows the host to signal the module to not send data in the serial transmit buffer out the UART or SPI port. RTS and CTS flow control are enabled using the D6 and D7 commands. nCTS Flow Control If CTS flow control is enabled (D7 command), when the serial receive buffer is 17 bytes away from being full, the module de-asserts nCTS (sets it high) to signal to the host device to stop sending serial data. nCTS is re-asserted after the serial receive buffer has 34 bytes of space. nRTS Flow Control If RTS flow control is enabled (D6 command), data in the serial transmit buffer will not be sent out the DOUT pin as long as nRTS is de-asserted (set high). The host device should not de-assert nRTS for long periods of time to avoid filling the serial transmit buffer. If an RF data packet is received, and the serial transmit buffer does not have enough space for all of the data bytes, the entire RF data packet will be discarded.  Note: If the XBee is sending data out the UART or SPI port when nRTS is de-asserted (set high), the XBee could send up to 5 characters out the UART or SPI port after RTS is de-asserted. Serial Interface Protocols The XBee modules support both transparent and API (Application Programming Interface) serial interfaces. Transparent Operation When operating in transparent mode, the modules act as a serial line replacement. All UART or SPI data received through the respective ports is queued up for RF transmission. When RF data is received, the data is sent out through the UART or SPI port. The module configuration parameters are configured using the AT command mode interface. Data is buffered in the serial receive buffer until one of the following causes the data to be packetized and transmitted: No serial characters are received for the amount of time determined by the RO (Packetization Time-out) parameter. If RO = 0, packetization begins when a character is received.  buffer before the sequence is transmitted.  
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 38  API Operation API operation is an alternative to transparent operation. The frame-based API extends the level to which a host application can interact with the networking capabilities of the module. When in API mode, all data entering and leaving the module is contained in frames that define operations or events within the module.  Transmit Data Frames (received through the DIN pin (pin 3)) include:  ata Frame  include:  -  The API provides alternative means of configuring modules and routing data at the host application layer. A host application can send data frames to the module that contain address and payload information instead of using command mode to modify addresses. The module will send data frames to the application containing status packets; as well as source, and payload information from received data packets. The API operation option facilitates many operations such as the examples cited below:  -> Transmitting data to multiple destinations without entering Command Mode  -> Receive success/failure status of each transmitted RF packet  -> Identify the source address of each received packet  A Comparison of Transparent and API Operation The following table compares the advantages of transparent and API modes of operation: Transparent Operation Features Simple Interface All received serial data is transmitted unless the module is in command mode. Easy to support It is easier for an application to support transparent operation and command mode. API Operation Features Easy to manage data transmissions to multiple destinations Transmitting RF data to multiple remotes only requires changing the address in the API frame.  This Process is much faster than transparent operation where the application must enter AT command mode, change the address, exit command mode, and then transmit data.                 Each API transmission can return a transmit status frame indicating the success or reason for failure Received data frames indicate the sender's address All received RF data API frames indicate the source address. Advanced ZigBee addressing support API transmit and receive frames can expose ZigBee addressing fields including source and destination endpoints, cluster ID and profile ID.  This makes it easy to support ZDO commands and public profile traffic.
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 39  Advanced Networking diagnostics API frames can provide indication of IO samples from remote devices, and node identification messages. Remote Configuration Set/read configuration commands can be sent to remote devices to configure them as needed using the API.  As a general rule of thumb, API firmware is recommended when a device:      multiple devices, and the application needs to know which device sent which packet     If the above conditions do not apply (e.g. a sensor node, router, or a simple application), then AT firmware might be suitable. It is acceptable to use a mixture of devices running API and AT firmware in a network.
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 40  Modes of Operation Idle Mode When not receiving or transmitting data, the RF module is in Idle Mode. The module shifts into the other modes of operation under the following conditions:   (Valid RF data is received through the antenna)     Transmit Mode When serial data is received and is ready for packetization, the RF module will exit Idle Mode and attempt to transmit the data. The destination address determines which node(s) will receive the data.  Prior to transmitting the data, the module ensures that a 16-bit network address and route to the destination node have been established.  If the destination 16-bit network address is not known, network address discovery will take place. If a route is not known, route discovery will take place for the purpose of establishing a route to the destination node. If a module with a matching network address is not discovered, the packet is discarded. The data will be transmitted once a route is established. If route discovery fails to establish a route, the packet will be discarded.   When data is transmitted from one node to another, a network-level acknowledgement is transmitted back across the established route to the source node. This acknowledgement packet indicates to the source node that the data
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 41  packet was received by the destination node. If a network acknowledgement is not received, the source node will re-transmit the data.  It is possible in rare circumstances for the destination to receive a data packet, but for the source to not receive the network acknowledgment. In this case, the source will retransmit the data, which could cause the destination to receive the same data packet multiple times. The XBee modules do not filter out duplicate packets. The application should include provisions to address this potential issue  See Data Transmission and Routing in chapter 4 for more information. Receive Mode If a valid RF packet is received, the data is transferred to the serial transmit buffer. Command Mode To modify or read RF Module parameters, the module must first enter into Command Mode - a state in which incoming serial characters are interpreted as commands. Refer to the API Mode section in chapter 9 for an alternate means of configuring modules.  AT Command Mode To Enter AT Command Mode:  Send the 3- times before and after the combelow.]  Default AT Command Mode Sequence (for transition to Command Mode):   hin one second [CC (Command Sequence Character) parameter = 0x2B.]   Once the AT command mode sequence has been issued, the module sends an "OK\r" out the UART or SPI pad. The "OK\r" characters can be delayed if the module has not finished transmitting received serial data.  When command mode has been entered, the command mode timer is started (CT command), and the module is able to receive AT commands on the UART or SPI port.  All of the parameter values in the sequence can be modified to reflect user preferences. NOTE: Failure to enter AT Command Mode is most commonly due to baud rate mismatch. By default, the BD (Baud Rate) parameter = 3 (9600 bps).  To Send AT Commands:  Send AT commands and parameters using the syntax shown below.
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 42   To read a parameter value stored in the RF module’s register, omit the parameter field. store the new value to non-volatile (long term) memory, subsequently send the WR (Write) command.  saved to non-volatile memory using the WR (Write) Command. Otherwise, parameters are restored to previously saved values after the module is reset. Command Response When a command is sent to the module, the module will parse and execute the command. Upon of a   Applying Command Changes Any changes made to the configuration command registers through AT commands will not take effect until the changes are applied. For example, sending the BD command to change the baud rate will not change the actual baud rate until changes are applied. Changes can be applied in one of the following ways:    To Exit AT Command Mode: 1. Send the ATCN (Exit Command Mode) command (followed by a carriage return).  [OR]  2.       If no valid AT Commands are received within the time specified by CT (Command Mode Timeout) Command, the RF module automatically returns to Idle Mode. For an example of programming the RF module using AT Commands and descriptions of each configurable parameter, please see the Command Reference Table chapter.
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 43  Sleep Mode Sleep modes allow the RF module to enter states of low power consumption when not in use. The XBee RF modules support both pin sleep (sleep mode entered on pin transition) and cyclic sleep (module sleeps for a fixed time). XBee sleep modes are discussed in detail in chapter 6.
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 44  3. XBee ZigBee Networks Introduction to ZigBee ZigBee is an open global standard built on the IEEE 802.15.4 MAC/PHY. ZigBee defines a network layer above the 802.15.4 layers to support advanced mesh routing capabilities. The ZigBee specification is developed by a growing consortium of companies that make up the ZigBee Alliance. The Alliance is made up of over 300 members, including semiconductor, module, stack, and software developers. ZigBee Stack Layers The ZigBee stack consists of several layers including the PHY, MAC, Network, Application Support Sublayer (APS), and ZigBee Device Objects (ZDO) layers. Technically, an Application Framework (AF) layer also exists, but will be grouped with the APS layer in remaining discussions. The ZigBee layers are shown in the figure below.  A description of each layer appears in the following table: ZigBee Layer Description PHY Defines the physical operation of the ZigBee device including receive sensitivity, channel rejection, output power, number of channels, chip modulation, and transmission rate specifications. Most ZigBee applications operate on the 2.4 GHz ISM band at a 250kbps data rate. See the IEEE 802.15.4 specification for details. MAC Manages RF data transactions between neighboring devices (point to point).  The MAC includes services such as transmission retry and acknowledgement management, and collision avoidance techniques (CSMA-CA) Network Adds routing capabilities that allow RF data packets to traverse multiple devices (multiple "hops") to route data from source to destination (peer to peer). APS (AF) Application layer that defines various addressing objects including profiles, clusters, and endpoints. ZDO Application layer that provides device and service discovery features and advanced network management capabilities.  Networking concepts Device Types ZigBee defines three different device types: coordinator, router, and end device.  Node Types / Sample of a Basic ZigBee Network Topology  A coordinator has the following characteristics: it
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 45  -bit and 16-bit) to start the network    --should be mains powered  ildren. A router has the following characteristics: it     --should be mains powered.   An end device has the following characteristics: it   etwork   -powered. An example of such a network is shown below:  In ZigBee networks, the coordinator must select a PAN ID (64-bit and 16-bit) and channel to start a network. After that, it behaves essentially like a router. The coordinator and routers can allow other devices to join the network and can route data.  After an end device joins a router or coordinator, it must be able to transmit or receive RF data through that router or coordinator. The router or coordinator that allowed an end device to join becomes the "parent" of the end device. Since the end device can sleep, the parent must be able to buffer or retain incoming data packets destined for the end device until the end device is able to wake and receive the data. PAN ID ZigBee networks are called personal area networks or PANs. Each network is defined with a unique PAN identifier (PAN ID). This identifier is common among all devices of the same network. ZigBee devices are either preconfigured with a PAN ID to join, or they can discovery nearby networks and select a PAN ID to join.  ZigBee supports both a 64-bit and a 16-bit PAN ID. Both PAN IDs are used to uniquely identify a network. Devices on the same ZigBee network must share the same 64-bit and 16-bit PAN IDs. If multiple ZigBee networks are operating within range of each other, each should have unique PAN IDs.
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 46  The 16-bit PAN ID is used as a MAC layer addressing field in all RF data transmissions between devices in a network. However, due to the limited addressing space of the 16-bit PAN ID (65,535 possibilities); there is a possibility that multiple ZigBee networks (within range of each other) could use the same 16-bit PAN ID. To resolve potential 16-bit PAN ID conflicts, the ZigBee Alliance created a 64-bit PAN ID.  The 64-bit PAN ID (also called the extended PAN ID), is intended to be a unique, non-duplicated value. When a coordinator starts a network, it can either start a network on a preconfigured 64-bit PAN ID, or it can select a random 64-bit PAN ID. The 64-bit PAN ID is used during joining; if a device has a preconfigured 64-bit PAN ID, it will only join a network with the same 64-bit PAN ID. Otherwise, a device could join any detected PAN and inherit the PAN ID from the network when it joins. The 64-bit PAN ID is included in all ZigBee beacons and is used in 16-bit PAN ID conflict resolution.  Routers and end devices are typically configured to join a network with any 16-bit PAN ID as long as the 64-bit PAN ID is valid. Coordinators typically select a random 16-bit PAN ID for their network.  Since the 16-bit PAN ID only allows up to 65,535 unique values, and since the 16-bit PAN ID is randomly selected, provisions exist in ZigBee to detect if two networks (with different 64-bit PAN IDs) are operating on the same 16-bit PAN ID. If such a conflict is detected, the ZigBee stack can perform PAN ID conflict resolution to change the 16-bit PAN ID of the network in order to resolve the conflict. See the ZigBee specification for details.  To summarize, ZigBee routers and end devices should be configured with the 64-bit PAN ID of the network they want to join. They typically acquire the 16-bit PAN ID when they join a network. Operating Channel ZigBee utilizes direct-sequence spread spectrum modulation and operates on a fixed channel. The 802.15.4 PHY defines 16 operating channels (channels 11 to 26) in the 2.4 GHz frequency band. XBee modules support all 16 channels. ZigBee Application Layers: In Depth This section provides a more in-depth look at the ZigBee application stack layers (APS, ZDO) including a discussion on ZigBee endpoints, clusters, and profiles. Much of the material in this section can introduce unnecessary details of the ZigBee stack that are not required in many cases.  Skip this section if  -Digi ZigBee devices   Read this section if  -Digi ZigBee devices    Application Support Sublayer (APS) The APS layer in ZigBee adds support for application profiles, cluster IDs, and endpoints. Application Profiles Application profiles specify various device descriptions including required functionality for various devices. The collection of device descriptions forms an application profile. Application profiles can be defined as "Public" or "Private" profiles. Private profiles are defined by a manufacturer whereas public profiles are defined, developed,
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 47  and maintained by the ZigBee Alliance. Each application profile has a unique profile identifier assigned by the ZigBee Alliance. Examples of public profiles include:     The Smart Energy profile, for example, defines various device types including an energy service portal, load controller, thermostat, in-home display, etc. The Smart Energy profile defines required functionality for each device type. For example, a load controller must respond to a defined command to turn a load on or off. By defining standard communication protocols and device functionality, public profiles allow interoperable ZigBee solutions to be developed by independent manufacturers. Digi XBee ZB firmware operates on a private profile called the Digi Drop-In Networking profile. However, the API firmware in the module can be used in many cases to talk to devices in public profiles or non-Digi private profiles. See the API Operations chapter for details. Clusters A cluster is an application message type defined within a profile. Clusters are used to specify a unique function, service, or action. For example, the following are some clusters defined in the home automation profile:  - Used to switch devices on or off (lights, thermostats, etc.)  - Used to control devices that can be set to a level between on and off  - Controls the color of color capable devices. Each cluster has an associated 2-byte cluster identifier (cluster ID). The cluster ID is included in all application transmissions. Clusters often have associated request and response messages. For example, a smart energy gateway (service portal) might send a load control event to a load controller in order to schedule turning on or off an appliance. Upon executing the event, the load controller would send a load control report message back to the gateway.  Devices that operate in an application profile (private or public) must respond correctly to all required clusters. For example, a light switch that will operate in the home automation public profile must correctly implement the On/Off and other required clusters in order to interoperate with other home automation devices. The ZigBee Alliance has defined a ZigBee Cluster Library (ZCL) that contains definitions or various general use clusters that could be implemented in any profile. XBee modules implement various clusters in the Digi private profile. In addition, the API can be used to send or receive messages on any cluster ID (and profile ID or endpoint). See the Explicit Addressing ZigBee Command API frame in chapter 3 for details. Endpoints The APS layer includes supports for endpoints. An endpoint can be thought of as a running application, similar to a TCP/IP port. A single device can support one or more endpoints. Each application endpoint is identified by a 1-byte value, ranging from 1 to 240. Each defined endpoint on a device is tied to an application profile. A device could, for example, implement one endpoint that supports a Smart Energy load controller, and another endpoint that supports other functionality on a private profile.
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 48  ZigBee Device Profile Profile ID 0x0000 is reserved for the ZigBee Device Profile. This profile is implemented on all ZigBee devices. Device Profile defines many device and service discovery features and network management capabilities. Endpoint 0 is a reserved endpoint that supports the ZigBee Device Profile. This endpoint is called the ZigBee Device Objects (ZDO) endpoint. ZigBee Device Objects (ZDO) The ZDO (endpoint 0) supports the discovery and management capabilities of the ZigBee Device Profile. A complete listing of all ZDP services is included in the ZigBee specification. Each service has an associated cluster ID.  The XBee ZB firmware allows applications to easily send ZDO messages to devices in the network using the API. See the ZDO Transmissions section in chapter 4 for details. Coordinator Operation Forming a Network The coordinator is responsible for selecting the channel, PAN ID (16-bit and 64-bit), security policy, and stack profile for a network. Since a coordinator is the only device type that can start a network, each ZigBee network must have one coordinator. After the coordinator has started a network, it can allow new devices to join the network. It can also route data packets and communicate with other devices on the network.  To ensure the coordinator starts on a good channel and unused PAN ID, the coordinator performs a series of scans to discover any RF activity on different channels (energy scan) and to discover any nearby operating PANs (PAN scan). The process for selecting the channel and PAN ID are described in the following sections. Channel Selection When starting a network, the coordinator must select a "good" channel for the network to operate on. To do this, it performs an energy scan on multiple channels (frequencies) to detect energy levels on each channel. Channels with excessive energy levels are removed from its list of potential channels to start on. PAN ID Selection After completing the energy scan, the coordinator scans its list of potential channels (remaining channels after the energy scan) to obtain a list of neighboring PANs. To do this, the coordinator sends a beacon request (broadcast) transmission on each potential channel. All nearby coordinators and routers (that have already joined a ZigBee network) will respond to the beacon request by sending a beacon back to the coordinator. The beacon contains information about the PAN the device is on, including the PAN identifiers (16-bit and 64-bit). This scan (collecting beacons on the potential channels) is typically called an active scan or PAN scan. After the coordinator completes the channel and PAN scan, it selects a random channel and unused 16-bit PAN ID to start on. Security Policy The security policy determines which devices are allowed to join the network, and which device(s) can authenticate joining devices. See chapter 5 for a detailed discussion of various security policies. Persistent Data Once a coordinator has started a network, it retains the following information through power cycle or reset events:
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 49      the coordinator). The coordinator will retain this information indefinitely until it leaves the network. When the coordinator leaves a network and starts a new network, the previous PAN ID, operating channel, and child table data are lost. XBee ZB Coordinator Startup The following commands control the coordinator network formation process. Network formation commands used by the coordinator to form a network. Command Description ID Used to determine the 64-bit PAN ID.  If set to 0 (default), a random 64-bit PAN ID will be selected. SC Determines the scan channels bitmask (up to 16 channels) used by the coordinator when forming a network.  The coordinator will perform an energy scan on all enabled SC channels.  It will then perform a PAN ID scan and then form the network on one of the SC channels SD Set the scan duration period.  This value determined how long the coordinator performs an energy scan or PAN ID scan on a given channel. ZS Set the ZigBee Stack profile for the network. EE Enable or disable security in the network. NK Set the network security key for the network.  If set to 0 (default), a random network security key will be used. KY Set the trust center link key for the network.  If set to 0 (default), a random link key will be used. EO Set the security policy for the network.  Once the coordinator starts a network, the network configuration settings and child table data persist through power cycles as mentioned in the "Persistent Data" section. When the coordinator has successfully started a network, it    RT (API firmware only). These behaviors are configurable using the following commands: Command Description NJ Sets the permit-join time on the coordinator, measured in seconds. D5 Enables the Associate LED functionality LT Sets the Associate LED blink time when joined.  Default is 1 blink per second.
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 50  If any of the command values in the network formation commands table changes, the coordinator will leave its current network and start a new network, possibly on a different channel. Note that command changes must be applied (AC or CN command) before taking effect.  Permit Joining The permit joining attribute on the coordinator is configurable with the NJ command. NJ can be configured to always allow joining, or to allow joining for a short time.  Joining Always Enabled If NJ=0xFF (default), joining is permanently enabled. This mode should be used carefully. Once a network has been deployed, the application should strongly consider disabling joining to prevent unwanted joins from occurring. Joining Temporarily Enabled If NJ < 0xFF, joining will be enabled only for a number of seconds, based on the NJ parameter. The timer is started once the XBee joins a network. Joining will not be re-enabled if the module is power cycled or reset. The following mechanisms can restart the permit-joining timer:     press - enables joining for 1 minute). Resetting the Coordinator When the coordinator is reset or power cycled, it checks its PAN ID, operating channel and stack profile against the network configuration settings (ID, CH, and ZS). It also verifies the saved security policy against the security configuration settings (EE, NK, KY). If the coordinator's PAN ID, operating channel, stack profile, or security policy is not valid based on its network and security configuration settings, then the coordinator will leave the network and attempt to form a new network based on its network formation command values. To prevent the coordinator from leaving an existing network, the WR command should be issued after all network formation commands have been configured in order to retain these settings through power cycle or reset events. Leaving a Network There are a couple of mechanisms that will cause the coordinator to leave its current PAN and start a new network based on its network formation parameter values. These include the following:  -bit PAN ID is invalid.      and migrate to a different channel.  ommand with a parameter of 4.  Note that changes to ID, SC, ZS, and security command values only take effect when changes are applied (AC or CN commands).
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 51  Replacing a Coordinator (Security Disabled Only) In rare occasions, it may become necessary to replace an existing coordinator in a network with a new physical device. If security is not enabled in the network, a replacement XBee coordinator can be configured with the PAN ID (16-bit and 64-bit), channel, and stack profile settings of a running network in order to replace an existing coordinator.  NOTE: Having two coordinators on the same channel, stack profile, and PAN ID (16-bit and 64-bit) can cause problems in the network and should be avoided. When replacing a coordinator, the old coordinator should be turned off before starting the new coordinator.  To replace a coordinator, the following commands should be read from a device on the network: AT Command Description OP Read the operating 64-bit PAD ID. OI Read the operating 16-bit PAN ID. CH Read the operating channel. ZS Read the stack profile.  Each of the commands listed above can be read from any device on the network. (These parameters will be the same on all devices in the network.) After reading these commands from a device on the network, these parameter values should be programmed into the new coordinator using the following commands. AT Command Description ID Set the 64-bit PAN ID to match the read OP value. II Set the initial 16-bit PAN ID to match the read OI value. SC Set the scan channels bitmask to enable the read operating channel (CH command).  For example, if the operating channel is 0x0B, set SC to 0x0001.  If the operating channel is 0x17, set SC to 0x1000. ZS Set the stack profile to match the read ZS value.  Note: II is the initial 16-bit PAN ID. Under certain conditions, the ZigBee stack can change the 16-bit PAN ID of the network. For this reason, the II command cannot be saved using the WR command. Once II is set, the coordinator leaves the network and starts on the 16-bit PAN ID specified by II. Example: Starting a Coordinator 1. Set SC and ID to the desired scan channels and PAN ID values. (The defaults should suffice.)  2. If SC or ID is changed from the default, issue the WR command to save the changes.
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 52  3. If SC or ID is changed from the default, apply changes (make SC and ID changes take effect) either by sending the AC command or by exiting AT command mode.  4. The Associate LED will start blinking once the coordinator has selected a channel and PAN ID.  5. The API Modem Status frame ("Coordinator Started") is sent out the UART (API firmware only). 6. Reading the AI command (association status) will return a value of 0, indicating a successful startup.  7. Reading the MY command (16-bit address) will return a value of 0, the ZigBee-defined 16-bit address of the coordinator. After startup, the coordinator will allow joining based on its NJ value. Example: Replacing a Coordinator (security disabled) 1. Read the OP, OI, CH, and ZS commands on the running coordinator.  2. Set the ID, SC, and ZS parameters on the new coordinator, followed by WR command to save these parameter values.  3. Turn off the running coordinator.  4. Set the II parameter on the new coordinator to match the read OI value on the old coordinator.  5. Wait for the new coordinator to start (AI=0). Router Operation Routers must discover and join a valid ZigBee network before they can participate in a ZigBee network. After a router has joined a network, it can allow new devices to join the network. It can also route data packets and communicate with other devices on the network.   Discovering ZigBee Networks  To discover nearby ZigBee networks, the router performs a PAN (or active) scan, just like the coordinator does when it starts a network. During the PAN scan, the router sends a beacon request (broadcast) transmission on the first channel in its scan channels list. All nearby coordinators and routers operating on that channel (that are already part of a ZigBee network) respond to the beacon request by sending a beacon back to the router. The beacon contains information about the PAN the nearby device is on, including the PAN identifier (PAN ID), and whether or not joining is allowed. The router evaluates each beacon received on the channel to determine if a valid PAN is found. A router considers a PAN to be valid if the PAN:  -bit PAN ID (PAN ID matches ID if ID > 0)     If a valid PAN is not found, the router performs the PAN scan on the next channel in its scan channels list and continues scanning until a valid network is found, or until all channels have been scanned. If all channels have been scanned and a valid PAN was not discovered, all channels will be scanned again.  The ZigBee Alliance requires that certified solutions not send beacon request messages too frequently. To meet certification requirements, the XBee firmware attempts 9 scans per minute for the first 5 minutes, and 3 scans per minute thereafter. If a valid PAN is within range of a joining router, it should typically be discovered within a few seconds. Joining a Network Once the router discovers a valid network, it sends an association request to the device that sent a valid beacon requesting a join on the ZigBee network. The device allowing the join then sends an association response frame that either allows or denies the join.
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 53  When a router joins a network, it receives a 16-bit address from the device that allowed the join. The 16-bit address is randomly selected by the device that allowed the join.   Authentication In a network where security is enabled, the router must then go through an authentication process. See the Security chapter for a discussion on security and authentication.   After the router is joined (and authenticated, in a secure network), it can allow new devices to join the network.  Persistent Data Once a router has joined a network, it retains the following information through power cycle or reset events:        The router will retain this information indefinitely until it leaves the network. When the router leaves a network, the previous PAN ID, operating channel, and child table data are lost.  XBee ZB Router Joining  When the router is powered on, if it is not already joined to a valid ZigBee network, it immediately attempts to find and join a valid ZigBee network.  Note: The DJ command can be set to 1 to disable joining. The DJ parameter cannot be written with WR, so a power cycle always clears the DJ setting. The following commands control the router joining process. Command Description ID Sets the 64-bit PAN ID to join.  Setting ID=0 allows the router to join any 64-bit PAN ID. SC Set the scan channels bitmask that determines which channels a router will scan to find a valid network.  SC on the router should be set to match SC on the coordinator.  For example, setting SC to 0x281 enables scanning on channels 0x0b, 0x12, and 0x14, in that order. SD Set the scan duration, or time that the router will listen for beacons on each channel. ZS Sets the stack profile on the device. EE Enable or disable security in the network.  This must be set to match the EE value (security policy) of the coordinator. KY Set the trust center link key.  If set to 0 (default), the link key is expected to be obtained (unencrypted) during joining.
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 54  Once the router joins a network, the network configuration settings and child table data persist through power cycles as mentioned in the "Persistent Data" section previously.  If joining fails, the status of the last join attempt can be read in the AI command register. If any of the above command values change, when command register changes are applied (AC or CN commands), the router will leave its current network and attempt to discover and join a new valid network. When a ZB router has successfully joined a network, it:    ends an API modem status frame ("associated") out the UART (API firmware only). These behaviors are configurable using the following commands: Command Description NJ Sets the permit-join time on the router, or the time that it will allow new devices to join the network, measured in seconds.  If NJ=0xFF, permit joining will always be enabled. D5 Enables the Associate LED functionality. LT Sets the Associate LED blink time when joined.  Default is 2 blinks per second (router).  Permit Joining  The permit joining attribute on the router is configurable with the NJ command. NJ can be configured to always allow joining, or to allow joining for a short time. Joining Always Enabled If NJ=0xFF (default), joining is permanently enabled. This mode should be used carefully. Once a network has been deployed, the application should strongly consider disabling joining to prevent unwanted joins from occurring. Joining Temporarily Enabled If NJ < 0xFF, joining will be enabled only for a number of seconds, based on the NJ parameter. The timer is started once the XBee joins a network. Joining will not be re-enabled if the module is power cycled or reset. The following mechanisms can restart the permit-joining timer:     press - enables joining for 1 minute)    Router Network Connectivity Once a router joins a ZigBee network, it remains connected to the network on the same channel and PAN ID as long as it is not forced to leave. (See Leaving a Network section for details.) If the scan channels (SC), PAN ID (ID) and security settings (EE, KY) do not change after a power cycle; the router will remain connected to the network after a power cycle.  If a router may physically move out of range of the network it initially joined, the application should include provisions to detect if the router can still communicate with the original network. If communication with the
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 55  original network is lost, the application may choose to force the router to leave the network (see Leaving a Network section for details). The XBee firmware includes two provisions to automatically detect the presence of a network, and leave if the check fails.  Power-On Join Verification The JV command (join verification) enables the power-on join verification check. If enabled, the XBee will attempt to discover the 64-bit address of the coordinator when it first joins a network. Once it has joined, it will also attempt to discover the 64-bit address of the coordinator after a power cycle event. If 3 discovery attempts fail, the router will leave the network and try to join a new network. Power-on join verification is disabled by default (JV defaults to 0).  Network Watchdog The NW command (network watchdog timeout) can be used for a powered router to periodically check for the presence of a coordinator to verify network connectivity. The NW command specifies a timeout in minutes where the router must receive communication from the coordinator or data collector. The following events restart the network watchdog timer:   -to-one route request was received (from any device)  anging the value of NW. If the watchdog timer expires (no valid data received for NW time), the router will attempt to discover the 64-bit address of the coordinator. If the address cannot be discovered, the router records one watchdog timeout. Once three consecutive network watchdog timeouts have expired (3 * NW) and the coordinator has not responded to the address discovery attempts, the router will leave the network and attempt to join a new network. Anytime a router receives valid data from the coordinator or data collector, it will clear the watchdog timeouts counter and restart the watchdog timer. The watchdog timer (NW command) is settable to several days. The network watchdog feature is disabled by default (NW defaults to 0).
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 56     Leaving a Network There are a couple of mechanisms that will cause the router to leave its current PAN and attempt to discover and join a new network based on its network joining parameter values. These include the following:  -bit PAN ID is invalid.     send a broadcast transmission, causing all devices in the network to leave and migrate to a different channel.   Note that changes to ID, SC, ZS, and security command values only take effect when changes are applied (AC or CN commands).
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 57  Resetting the Router When the router is reset or power cycled, it checks its PAN ID, operating channel and stack profile against the network configuration settings (ID, SC, and ZS). It also verifies the saved security policy is valid based on the security configuration commands (EE, KY). If the router's PAN ID, operating channel, stack profile, or security policy is invalid, the router will leave the network and attempt to join a new network based on its network joining command values.  To prevent the router from leaving an existing network, the WR command should be issued after all network joining commands have been configured in order to retain these settings through power cycle or reset events. Example:  Joining a Network After starting a coordinator (that is allowing joins), the following steps will cause a router to join the network:  1. Set ID to the desired 64-bit PAN ID, or to 0 to join any PAN.  2. Set SC to the list of channels to scan to find a valid network.  3. If SC or ID is changed from the default, apply changes (make SC and ID changes take effect) by issuing the AC or CN command.  4. The Associate LED will start blinking once the router has joined a PAN.  5. If the Associate LED is not blinking, the AI command can be read to determine the cause of join failure.  6. Once the router has joined, the OP and CH commands will indicate the operating 64-bit PAN ID and channel the router joined.  7. The MY command will reflect the 16-bit address the router received when it joined.  8. The API Modem Status frame ("Associated") is sent out the UART (API firmware only).  9. The joined router will allow other devices to join for a time based on its NJ setting. End Device Operation Similar to routers, end devices must also discover and join a valid ZigBee network before they can participate in a network. After an end device has joined a network, it can communicate with other devices on the network. Since end devices are intended to be battery powered and therefore support low power (sleep) modes, end devices cannot allow other devices to join, nor can they route data packets. Discovering ZigBee Networks End devices go through the same process as routers to discover networks by issuing a PAN scan. After sending the broadcast beacon request transmission, the end device listens for a short time in order to receive beacons sent by nearby routers and coordinators on the same channel. The end device evaluates each beacon received on the channel to determine if a valid PAN is found. An end device considers a PAN to be valid if the PAN: -bit PAN ID (PAN ID matches ID if ID > 0)    devices (see End Device Capacity section below). If a valid PAN is not found, the end device performs the PAN scan on the next channel in its scan channels list and continues this process until a valid network is found, or until all channels have been scanned. If all channels have been scanned and a valid PAN was not discovered, the end device may enter a low power sleep state and scan again later.  If scanning all SC channels fails to discover a valid PAN, XBee ZB modules will attempt to enter a low power state and will retry scanning all SC channels after the module wakes from sleeping. If the module cannot enter a low power state, it will retry scanning all channels, similar to the router. To meet ZigBee Alliance requirements, the end device will attempt up to 9 scans per minute for the first 5 minutes, and 3 scans per minute thereafter. Note: The XBee ZB end device will not enter sleep until it has completed scanning all SC channels for a valid network.
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 58  Joining a Network Once the end device discovers a valid network, it joins the network, similar to a router, by sending an association request (to the device that sent a valid beacon) to request a join on the ZigBee network. The device allowing the join then sends an association response frame that either allows or denies the join. When an end device joins a network, it receives a 16-bit address from the device that allowed the join. The 16- bit address is randomly selected by the device that allowed the join. Parent Child Relationship Since an end device may enter low power sleep modes and not be immediately responsive, the end device relies on the device that allowed the join to receive and buffer incoming messages in its behalf until it is able to wake and receive those messages. The device that allowed an end device to join becomes the parent of the end device, and the end device becomes a child of the device that allowed the join. End Device Capacity Routers and coordinators maintain a table of all child devices that have joined called the child table. This table is a finite size and determines how many end devices can join. If a router or coordinator has at least one unused entry in its child table, the device is said to have end device capacity. In other words, it can allow one or more additional end devices to join. ZigBee networks should have sufficient routers to ensure adequate end device capacity. In the XBee ZB firmware, a coordinator can support 20 end devices, and a router can support 24 end devices. In ZB firmware, the NC command (number of remaining end device children) can be used to determine how many additional end devices can join a router or coordinator. If NC returns 0, then the router or coordinator device has no more end device capacity. (Its child table is full.) Also of note, since routers cannot sleep, there is no equivalent need for routers or coordinators to track joined routers. Therefore, there is no limit to the number of routers that can join a given router or coordinator device. (There is no "router capacity" metric.) Authentication In a network where security is enabled, the end device must then go through an authentication process. See chapter 5 for a discussion on security and authentication. Persistent Data The end device can retain its PAN ID, operating channel, and security policy information through a power cycle. However, since end devices rely heavily on a parent, the end device does an orphan scan to try and contact its parent. If the end device does not receive an orphan scan response (called a coordinator realignment command), it will leave the network and try to discover and join a new network. When the end device leaves a network, the previous PAN ID and operating channel settings are lost. Orphan Scans When an end device comes up from a power cycle, it performs an orphan scan to verify it still has a valid parent. The orphan scan is sent as a broadcast transmission and contains the 64-bit address of the end device. Nearby routers and coordinator devices that receive the broadcast check their child tables for an entry that contains the end device's 64-bit address. If an entry is found with a matching 64-bit address, the device sends a coordinator realignment command to the end device that includes the end device's 16-bit address, 16-bit PAN ID, operating channel, and the parent's 64-bit and 16-bit addresses. If the orphaned end device receives a coordinator realignment command, it is considered joined to the network. Otherwise, it will attempt to discover and join a valid network. XBee: ZB End Device Joining
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 59  When an end device is powered on, if it is not joined to a valid ZigBee network, or if the orphan scan fails to find a parent, it immediately attempts to find and join a valid ZigBee network. Note: The DJ command can be set to 1 to disable joining. The DJ parameter cannot be written with WR, so a power cycle always clears the DJ setting.  Similar to a router, the following commands control the end device joining process. Network joining commands used by an end device to join a network. Command Description ID Sets the 64-bit PAN ID to join.  Setting ID=0 allows the router to join any 64-bit PAN ID. SC Set the scan channels bitmask that determines which channels a router will scan to find a valid network.  SC on the end device should be set to match SC on the coordinator and router.  For example, setting SC to 0x281 enables scanning on channels 0x0b, 0x12, and 0x14, in that order. SD Set the scan duration, or time that the end device will listen for beacons on each channel. ZS Sets the stack profile on the device. EE Enable or disable security in the network.  This must be set to match the EE value (security policy) of the coordinator. KY Set the trust center link key.  If set to 0 (default), the link key is expected to be obtained (unencrypted) during joining.  Once the end device joins a network, the network configuration settings can persist through power cycles as mentioned in the "Persistent Data" section previously. If joining fails, the status of the last join attempt can be read in the AI command register.  If any of these command values changes, when command register changes are applied, the end device will leave its current network and attempt to discover and join a new valid network.  When a ZB end device has successfully started a network, it      These behaviors are configurable using the following commands: Command Description D5 Enables the Associate LED functionality. LT Sets the Associate LED blink time when joined.  Default is 2 blinks per second (router). SM, SP, ST, SN, SO Parameters that configure the sleep mode characteristics.  (See Managing End Devices chapter for details.)  Parent Connectivity
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 60  The XBee ZB end device sends regular poll transmissions to its parent when it is awake. These poll transmissions query the parent for any new received data packets. The parent always sends a MAC layer acknowledgment back to the end device. The acknowledgment indicates whether the parent has data for the end device or not.  If the end device does not receive an acknowledgment for 3 consecutive poll requests, it considers itself disconnected from its parent and will attempt to discover and join a valid ZigBee network. (See "Managing End Devices" chapter for details.) Resetting the End Device When the end device is reset or power cycled, if the orphan scan successfully locates a parent, the end device then checks its PAN ID, operating channel and stack profile against the network configuration settings (ID, SC, and ZS). It also verifies the saved security policy is valid based on the security configuration commands (EE, KY). If the end device's PAN ID, operating channel, stack profile, or security policy is invalid, the end device will leave the network and attempt to join a new network based on its network joining command values. To prevent the end device from leaving an existing network, the WR command should be issued after all network joining commands have been configured in order to retain these settings through power cycle or reset events. Leaving a Network There are a couple of mechanisms that will cause the end device to leave its current PAN and attempt to discover and join a new network based on its network joining parameter values. These include the following: ch that the current 64-bit PAN ID is invalid.  mask.    and migrate to a different channel.  CB command is issued with a parameter of 4.  that the end device fails to receive poll acknowledgment messages. Note that changes to command values only take effect when changes are applied (AC or CN commands). Example: Joining a Network After starting a coordinator (that is allowing joins), the following steps will cause an XBee end device to join the network: 1. Set ID to the desired 64-bit PAN ID, or to 0 to join any PAN.  2. Set SC to the list of channels to scan to find a valid network. 3. If SC or ID is changed from the default, apply changes (make SC and ID changes take effect) by issuing the AC or CN command.  4. The Associate LED will start blinking once the end device has joined a PAN.  5. If the Associate LED is not blinking, the AI command can be read to determine the cause of join failure.  6. Once the end device has joined, the OP and CH commands will indicate the operating 64-bit PAN ID and channel the end device joined.  7. The MY command will reflect the 16-bit address the router received when it joined.  8. The API Modem Status frame ("Associated") is sent out the UART (API firmware only).  9. The joined end device will attempt to enter low power sleep modes based on its sleep configuration commands (SM, SP, SN, ST, SO).
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 61  Channel Scanning As mentioned previously, routers and end devices must scan one or more channels to discover a valid network to join. When a join attempt begins, the XBee sends a beacon request transmission on the lowest channel specified in the SC (scan channels) command bitmask. If a valid PAN is found on the channel, the XBee will attempt to join the PAN on that channel. Otherwise, if a valid PAN is not found on the channel, it will attempt scanning on the next higher channel in the SC command bitmask.  The XBee will continue to scan each channel (from lowest to highest) in the SC bitmask until a valid PAN is found or all channels have been scanned. Once all channels have been scanned, the next join attempt will start scanning on the lowest channel specified in the SC command bitmask.  For example, if the SC command is set to 0x400F, the XBee would start scanning on channel 11 (0x0B) and scan until a valid beacon is found, or until channels 11, 12, 13, 14, and 25 have been scanned (in that order). Once an XBee router or end device joins a network on a given channel, if the XBee is told to leave (see "Leaving a Network" section), it will leave the channel it joined on and continue scanning on the next higher channel in the SC bitmask. For example, if the SC command is set to 0x400F, and the XBee joins a PAN on channel 12 (0x0C), if the XBee leaves the channel, it will start scanning on channel 13, followed by channels 14 and 25 if a valid network is not found. Once all channels have been scanned, the next join attempt will start scanning on the lowest channel specified in the SC command bitmask. Managing Multiple ZigBee Networks In some applications, multiple ZigBee networks may exist in proximity of each other. The application may need provisions to ensure the XBee joins the desired network. There are a number of features in ZigBee to manage joining among multiple networks. These include the following:  ering     Pan ID Filtering The XBee can be configured with a fixed PAN ID by setting the ID command to a non-zero value. If the PAN ID is set to a non-zero value, the XBee will only join a network with the same PAN ID. Preconfigured Security Keys Similar to PAN ID filtering, this method requires a known security key be installed on a router to ensure it will join a ZigBee network with the same security key. If the security key (KY command) is set to a non-zero value, and if security is enabled (EE command), an XBee router or end device will only join a network with the same security key. Permit Joining The Permit Joining parameter can be disabled in a network to prevent unwanted devices from joining. When a new device must be added to a network, permit-joining can be enabled for a short time on the desired network. In the XBee firmware, joining is disabled by setting the NJ command to a value less than 0xFF on all routers and coordinator devices. Joining can be enabled for a short time using the commissioning push-button (see Network Commissioning chapter for details) or the CB command. Application Messaging If the above mechanisms are not feasible, the application could build in a messaging framework between the coordinator and devices that join its network. For example, the application code in joining devices could send a transmission to the coordinator after joining a network, and wait to receive a defined reply message. If the
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 62  application does not receive the expected response message after joining, the application could force the XBee to leave and continue scanning (see NR parameter).
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 63  4. Transmission, Addressing, and Routing Addressing All ZigBee devices have two different addresses, a 64-bit and a 16-bit address. The characteristics of each are described below. 64-bit device Address The 64-bit address is a unique device address assigned during manufacturing. This address is unique to each physical device. The 64-bit address includes a 3-byte Organizationally Unique Identifier (OUI) assigned by the IEEE. The 64-bit address is also called the extended address. 16-bit Device Address A device receives a 16-bit address when it joins a ZigBee network. For this reason, the 16-bit address is also called the "network address". The 16-bit address of 0x0000 is reserved for the coordinator. All other devices receive a randomly generated address from the router or coordinator device that allows the join. The 16-bit address can change under certain conditions: -bit address   All ZigBee transmissions are sent using the source and destination 16-bit addresses. The routing tables on ZigBee devices also use 16-bit addresses to determine how to route data packets through the network. However, since the 16-bit address is not static, it is not a reliable way to identify a device.  To solve this problem, the 64-bit destination address is often included in data transmissions to guarantee data is delivered to the correct destination. The ZigBee stack can discover the 16-bit address, if unknown, before transmitting data to a remote. Application Layer Addressing ZigBee devices can support multiple application profiles, cluster IDs, and endpoints. (See "ZigBee Application Layers - In Depth" in chapter 3.) Application layer addressing allows data transmissions to be addressed to specific with other ZigBee devices outside of the Digi application profile    The API firmware provides a simple yet powerful interface that can easily send data to any profile ID, endpoint, and cluster ID combination on any device in a ZigBee network. Data Transmission ZigBee data packets can be sent as either unicast or broadcast transmissions. Unicast transmissions route data from one source device to one destination device, whereas broadcast transmissions are sent to many or all devices in the network. Broadcast Transmissions Broadcast transmissions within the ZigBee protocol are intended to be propagated throughout the entire network such that all nodes receive the transmission. To accomplish this, the coordinator and all routers that receive a broadcast transmission will retransmit the packet three times.  Note: when a router or coordinator delivers a broadcast transmission to an end device child, the transmission is only sent once (immediately after the end device wakes and polls the parent for any new data). See Parent Operation section in chapter 6 for details.
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 64   Each node that transmits the broadcast will also create an entry in a local broadcast transmission table. This entry is used to keep track of each received broadcast packet to ensure the packets are not endlessly transmitted. Each entry persists for 8 seconds. The broadcast transmission table holds 8 entries. For each broadcast transmission, the ZigBee stack must reserve buffer space for a copy of the data packet. This copy is used to retransmit the packet as needed. Large broadcast packets will require more buffer space. This information on buffer space is provided for general knowledge; the user does not and cannot change any buffer spacing. Buffer spacing is handled automatically by the XBee module. Since broadcast transmissions are retransmitted by each device in the network, broadcast messages should be used sparingly. Unicast Transmissions Unicast transmissions are sent from one source device to another destination device. The destination device could be an immediate neighbor of the source, or it could be several hops away. Unicast transmissions that are sent along a multiple hop path require some means of establishing a route to the destination device. See the "RF Packet Routing" section in chapter 4 for details.   Address Resolution As mentioned previously, each device in a ZigBee network has both a 16-bit (network) address and a 64-bit (extended) address. The 64-bit address is unique and assigned to the device during manufacturing, and the 16-bit address is obtained after joining a network. The 16-bit address can also change under certain conditions.
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 65  When sending a unicast transmission, the ZigBee network layer uses the 16-bit address of the destination and each hop to route the data packet. If the 16-bit address of the destination is not known, the ZigBee stack includes a discovery provision to automatically discover the destination device's 16-bit address before routing the data. To discover a 16-bit address of a remote, the device initiating the discovery sends a broadcast address discovery transmission. The address discovery broadcast includes the 64-bit address of the remote device whose 16-bit address is being requested. All nodes that receive this transmission check the 64-bit address in the payload and compare it to their own 64-bit address. If the addresses match, the device sends a response packet back to the initiator. This response includes the remote's 16-bit address. When the discovery response is received, the initiator will then transmit the data.  Address Table Each ZigBee device maintains an address table that maps a 64-bit address to a 16-bit address. When a transmission is addressed to a 64-bit address, the ZigBee stack searches the address table for an entry with a matching 64-bit address, in hopes of determining the destination's 16-bit address. If a known 16-bit address is not found, the ZigBee stack will perform address discovery to discover the device's current 16- bit address. Sample Address Table 64-bit Address 16-bit Address 0013 A200 4000 0001  0x4414 0013 A200 400A 3568  0x1234 0013 A200 4004 1122  0xC200 0013 A200 4002 1123  0xFFFE (unknown)  The XBee modules can store up to 20 address table entries. For applications where a single device (e.g. coordinator) may send unicast transmissions to more than 20 devices, the application should implement an address table to store the 16-bit and 64-bit addresses for each remote device. Any XBee that will send data to more than 20 remotes should also use API firmware. The application can then send both the 16-bit and 64-bit addresses to the XBee in the API transmit frames which will significantly reduce the number of 16-bit address discoveries and greatly improve data throughput. If an application will support an address table, the size should ideally be larger than the maximum number of destination addresses the device will communicate with. Each entry in the address table should contain a 64-bit destination address and its last known 16-bit address. When sending a transmission to a destination 64-bit address, the application should search the address table for a matching 64-bit address. If a match is found, the 16-bit address should be populated into the 16-bit address field of the API frame. If a match is not found, the 16-bit address should be set to 0xFFFE (unknown) in the API transmit frame. The API provides indication of a remote device's 16-bit address in the following frames:  All receive data frames Rx Data (0x90) Rx Explicit Data (0x91) IO Sample Data (0x92) Node Identification Indicator (0x95) Route Record Indicator (0xA1) etc.  Transmit status frame (0x8B) The application should always update the 16-bit address in the address table when one of these frames is received to ensure the table has the most recently known 16-bit address. If a transmission failure occurs, the application should set the 16-bit address in the table to 0xFFFE (unknown).
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 66    Fragmentation Each unicast transmission may support up to 84 bytes of RF payload. (Enabling security or using source routing can reduce this number. See the NP command for details.) However, the XBee ZB firmware supports a ZigBee feature called fragmentation that allows a single large data packet to be broken up into multiple RF transmissions and reassembled by the receiver before sending data out its UART or SPI port. This is shown in the image below.  The API transmit frame can include up to 255 bytes of data, which will be broken up into multiple transmissions and reassembled on the receiving side. If one or more of the fragmented messages are not received by the receiving device, the receiver will drop the entire message, and the sender will indicate a transmission failure in the Tx Status API frame. Applications that do not wish to use fragmentation should avoid sending more than the maximum number of bytes in a single RF transmission. See the "Maximum RF Payload Size" section for details. Devices will not receive or reassemble fragmented RF packets if RTS flow control is enabled (D6 command). DATA Transmission Examples  AT Firmware To send a data packet in AT firmware, the DH and DL commands must be set to match the 64-bit address of the destination device. DH must match the upper 4-bytes, and DL must match the lower 4 bytes. Since the coordinator always receives a 16-bit address of 0x0000, a 64-bit address of 0x0000000000000000 is defined as the coordinator's address (in ZB firmware). The default values of DH and DL are 0x00, which sends data to the coordinator.   Example 1: Send a transmission to the coordinator (In this example, a '\r' refers to a carriage return character.) A router or end device can send data in two ways. First, set the destination address (DH and DL commands) to 0x00. 1. Enter command mode ('+++')  2. After receiving an OK\r, issue the following commands: a. ATDH0\r b. ATDL0\r c. ATCN\r  3. Verify that each of the 3 commands returned an OK\r response.  4. After setting these command values, all serial characters will be sent as a unicast transmission to the coordinator. Alternatively, if the coordinator's 64-bit address is known, DH and DL can be set to the coordinator's 64-bit address. Suppose the coordinator's address is 0x0013A200404A2244. 1. Enter command mode ('+++')  2. After receiving an OK\r, issue the following commands: a. ATDH13A200\r b. ATDL404A2244\ c. ATCN\r  3. Verify that each of the 3 commands returned an OK\r response.
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 67  4. After setting these command values, all serial characters will be sent as a unicast transmission to the coordinator.   API Firmware Use the transmit request, or explicit transmit request frame (0x10 and 0x11 respectively) to send data to the coordinator. The 64-bit address can either be set to 0x0000000000000000, or to the 64-bit address of the coordinator. The 16-bit address should be set to 0xFFFE when using the 64-bit address of all 0x00s. To send an ascii "1" to the coordinator's 0x00 address, the following API frame can be used: 7E 00 0F 10 01 0000 0000 0000 0000 FFFE 00 00 31 C0 If the explicit transmit frame is used, the cluster ID should be set to 0x0011, the profile ID to 0xC105, and the source and destination endpoints to 0xE8 (recommended defaults for data transmissions in the Digi profile.) The same transmission could be sent using the following explicit transmit frame: 7E 00 15 11 01 0000 0000 0000 0000 FFFE E8 E8 0011 C105 00 00 31 18 Notice the 16-bit address is set to 0xFFFE. This is required when sending to a 64-bit address of 0x00s. Now suppose the coordinator's 64-bit address is 0x0013A200404A2244. The following transmit request API frame (0x10) will send an ASCII "1" to the coordinator: 7E 00 0F 10 01 0013 A200 404A 2244 0000 0000 31 18 Example 2: Send a broadcast transmission (In this example, a '\r' refers to a carriage return character.) Perform the following steps to configure a broadcast transmission: 1. Enter command mode ('+++')  2. After receiving an OK\r, issue the following commands: a. ATDH0\r b. ATDLffff\r c. ATCN\r  3. Verify that each of the 3 commands returned an OK\r response  4. After setting these command values, all serial characters will be sent as a broadcast transmission. API Firmware This example will use the transmit request API frame (0x10) to send an ASCII "1" in a broadcast transmission. To send an ascii "1" as a broadcast transmission, the following API frame can be used: 7E 00 0F 10 01 0000 0000 0000 FFFF FFFE 00 00 31 C2 Notice the destination 16-bit address is set to 0xFFFE for broadcast transmissions. RF Packet Routing Unicast transmissions may require some type of routing. ZigBee includes several different ways to route data, each with its own advantages and disadvantages. These are summarized in the table below.
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 68  Routing Approach Description When to Use Ad hoc On-demand distance Vector (AODV) Mesh Routing Routing paths are created between source and destination, possibly traversing multiple nodes ("hops").  Each device knows who to send data to eventually reaching the destination. Use in networks that will not scale beyond about 40 destination devices. Many-to-One Routing A single broadcast transmission configured reverse routes on all devices into the device that sends the broadcast Useful when many remote devices must send data to a single gateway or collector device. Source Routing Data packets include the entire route the packet should traverse to get from source to destination. Improves routing efficiency in large networks (over 40 remote devices)  Note  End devices do not make use of these routing protocols. Rather, an end device sends a unicast transmission to its parent and allows the parent to route the data packet in its behalf. Link Status Transmission Before discussing the various routing protocols, it is worth understanding the primary mechanism in ZigBee for establishing reliable bi-directional links. This mechanism is especially useful in networks that may have a mixture of devices with varying output power and/or receiver sensitivity levels. Each coordinator or router device periodically sends a link status message. This message is sent as a 1-hop broadcast transmission, received only by one-hop neighbors. The link status message contains a list of neighboring devices and incoming and outgoing link qualities for each neighbor. Using these messages, neighboring devices can determine the quality of a bi-directional link with each neighbor and use that information to select a route that works well in both directions. For example, consider a network of two neighboring devices that send periodic link status messages. Suppose that the output power of device A is +18dBm, and the output power of device B is +3dBm (considerably less than the output power of device A). The link status messages might indicate the following:
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 69  This mechanism enables devices A and B to recognize that the link is not reliable in both directions and select a different neighbor when establishing routes. (Such links are called asymmetric links, meaning the link quality is not similar in both directions.) When a router or coordinator device powers on, it sends link status messages every couple seconds to attempt to discover link qualities with its neighbors quickly. After being powered on for some time, the link status messages are sent at a much slower rate (about every 3-4 times per minute). AODV Mesh Routing ZigBee employs mesh routing to establish a route between the source device and the destination. Mesh routing allows data packets to traverse multiple nodes (hops) in a network to route data from a source to a destination. Routers and coordinators can participate in establishing routes between source and destination devices using a process called route discovery. The Route discovery process is based on the AODV (Ad-hoc On-demand Distance Vector routing) protocol.     AODV (Ad-hoc On-Demand Distance Vector) Routing Algorithm Routing under the AODV protocol is accomplished using tables in each node that store the next hop (intermediary node between source and destination nodes) for a destination node. If a next hop is not known, route discovery must take place in order to find a path. Since only a limited number of routes can be stored on a Router, route discovery will take place more often on a large network with communication between many different nodes. Node Destination Address Next Hop Address R3 Router 6 Coordinator c Router 7 Router 5 R5 Router 8 Router 6
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 70  When a source node must discover a route to a destination node, it sends a broadcast route request command. The route request command contains the source network address, the destination network address and a path cost field (a metric for measuring route quality). As the route request command is propagated through the network (refer to the Broadcast Transmission), each node that re-broadcasts the message updates the path cost field and creates a temporary entry in its route discovery table. Sample Route Request (Broadcast) Transmission Where R3 is Trying to Discover a Route to R6  When the destination node receives a route request commands. If the path cost stored in the route request is better than any previously received, the destination node will transmit a route reply packet to the node that originated the route request. Intermediate nodes receive and forward the route reply packet to the source node (the node that originated route request). Sample Route Reply (Unicast) Where R6 Sends a Route Reply to R3.  Note: R6 could send multiple replies if it identifies a better route.   Retries and Acknowledgments ZigBee includes acknowledgment packets at both the Mac and Application Support (APS) layers. When data is transmitted to a remote device, it may traverse multiple hops to reach the destination. As data is transmitted from one node to its neighbor, an acknowledgment packet (Ack) is transmitted in the opposite direction to indicate that the transmission was successfully received. If the Ack is not received, the transmitting device will retransmit the data, up to 4 times. This Ack is called the Mac layer acknowledgment. In addition, the device that originated the transmission expects to receive an acknowledgment packet (Ack) from the destination device. This Ack will traverse the same path that the data traversed, but in the opposite direction.
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 71  If the originator fails to receive this Ack, it will retransmit the data, up to 2 times until an Ack is received. This Ack is called the ZigBee APS layer acknowledgment. Refer to the ZigBee specification for more details. Many-to-One Routing In networks where many devices must send data to a central collector or gateway device, AODV mesh routing requires significant overhead. If every device in the network had to discover a route before it could send data to the data collector, the network could easily become inundated with broadcast route discovery messages. Many-to-one routing is an optimization for these kinds of networks. Rather than require each device to do its own route discovery, a single many-to-one broadcast transmission is sent from the data collector to establish reverse routes on all devices. This is shown in the figure below. The left side shows the many broadcasts the devices can send when they create their own routes and the route replies generated by the data collector. The right side shows the benefits of many-to-one routing where a single broadcast creates reverse routes to the data collector on all routers.  The many-to-one broadcast is a route request message with the target discovery address set to the address of the data collector. Devices that receive this route request create a reverse many-to-one routing table entry to create a path back to the data collector. The ZigBee stack on a device uses historical link quality information about each neighbor to select a reliable neighbor for the reverse route. When a device sends data to a data collector, and it finds a many-to-one route in its routing table, it will transmit the data without performing a route discovery. The many-to-one route request should be sent periodically to update and refresh the reverse routes in the network. Applications that require multiple data collectors can also use many-to-one routing. If more than one data collector device sends a many-to-one broadcast, devices will create one reverse routing table entry for each collector.
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 72  In ZB firmware, the AR command is used to enable many-to-one broadcasting on a device. The AR command sets a time interval (measured in 10 second units) for sending the many to one broadcast transmission. (See the command table for details.) Source Routing In applications where a device must transmit data to many remotes, AODV routing would require performing one route discovery for each destination device to establish a route. If there are more destination devices than there are routing table entries, established AODV routes would be overwritten with new routes, causing route discoveries to occur more regularly. This could result in larger packet delays and poor network performance. ZigBee source routing helps solve these problems. In contrast to many-to-one routing that establishes routing paths from many devices to one data collector, source routing allows the collector to store and specify routes for many remotes. To use source routing, a device must use the API firmware, and it must send periodic many-to-one route request broadcasts (AR command) to create a many-to-one route to it on all devices. When remote devices send RF data using a many-to-one route, they first send a route record transmission. The route record transmission is unicast along the many-to-one route until it reaches the data collector. As the route record traverses the many-to-one route, it appends the 16-bit address of each device in the route into the RF payload. When the route record reaches the data collector, it contains the address of the sender, and the 16-bit address of each hop in the route. The data collector can store the routing information and retrieve it later to send a source routed packet to the remote. This is shown in the images below.
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 73   Acquiring Source Routes Acquiring source routes requires the remote devices to send a unicast to a data collector (device that sends many-to-one route request broadcasts). There are several ways to force remotes to send route record transmissions. 1. If the application on remote devices periodically sends data to the data collector, each transmission will force a route record to occur. 2. The data collector can issue a network discovery command (ND command) to force all XBee devices to send a network discovery response. Each network discovery response will be prefaced by a route record. 3. Periodic IO sampling can be enabled on remotes to force them to send data at a regular rate. Each IO sample would be prefaced by a route record. (See chapter 8 for details.) 4. If the NI string of the remote device is known, the DN command can be issued with the NI string of the remote in the payload. The remote device with a matching NI string would send a route record and a DN response. Storing Source Routes When a data collector receives a route record, it sends it out the UART as a Route Record Indicator API frame (0xA1). To use source routing, the application should receive these frames and store the source route information. Sending a Source Routed Transmission To send a source routed transmission, the application should send a Create Source Route API frame (0x21) to the XBee to create a source route in its internal source route table. After sending the Create Source Route API frame, the application can send data transmission or remote command request frames as needed to the same destination, or any destination in the source route. Once data must be sent to a new destination (a destination not
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 74  included in the last source route), the application should first send a new Create Source Route API frame. The XBee can buffer one source route that includes up to 10 hops (excluding source and destination). For example, suppose a network exists with a coordinator and 5 routers (R1, R2, R3, R4, and R5) with known source routes as shown below.  To send a source-routed packet to R3, the application must send a Create Source Route API frame (0x21) to the XBee, with a destination of R3, and 2 hops (R1 and R2). If the 64- bit address of R3 is 0x0013A200 404a1234 and the 16-bit addresses of R1, R2, and R3 are: Device 16-bit Address R1 0XAABB R2 0xCCDD R3 0xEEFF  Then the Create Source Route API frame would be: 7E 0012 21 00 0013A200 404A1234 EEFF 00 02 CCDD AABB 5C Where:  0x0012 - length  0x21 - API ID (create source route)  0x00 - frame ID (set to 0 always)  0x0013A200 404A1234 - 64-bit address of R3 (destination)  0xEEFF - 16-bit address of R3 (destination)  0x00 - Route options (set to 0)  0x02 - Number of intermediate devices in the source route  0xCCDD - Address of furthest device (1-hop from target)  0xAABB - Address of next-closer device  0x5C - Checksum (0xFF - SUM (all bytes after length)) Repairing Source Routes It is possible in a network to have an existing source route fail (i.e. a device in the route moves or goes down, etc.). If a device goes down in a source routed network, all routes that used the device will be broken. As mentioned previously, source routing must be used with many-to-one routing. (A device that uses source routing must also send a periodic many-to-one broadcast in order to keep routes fresh). If a source route is broken, remote devices must send in new route record transmissions to the data collector to provide it with a new source route. This requires that remote devices periodically send data transmissions into the data collector. See the earlier "Acquiring Source Routes" section for details. Retries and Acknowledgments
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 75  ZigBee includes acknowledgment packets at both the Mac and Application Support (APS) layers. When data is transmitted to a remote device, it may traverse multiple hops to reach the destination. As data is transmitted from one node to its neighbor, an acknowledgment packet (Ack) is transmitted in the opposite direction to indicate that the transmission was successfully received. If the Ack is not received, the transmitting device will retransmit the data, up to 4 times. This Ack is called the Mac layer acknowledgment. In addition, the device that originated the transmission expects to receive an acknowledgment packet (Ack) from the destination device. This Ack will traverse the same path that the data traversed, but in the opposite direction. If the originator fails to receive this Ack, it will retransmit the data, up to 2 times until an Ack is received. This Ack is called the ZigBee APS layer acknowledgment. Refer to the ZigBee specification for more details. Encrypted Transmissions Encrypted transmissions are routed similar to non-encrypted transmissions with one exception. As an encrypted packet propagates from one device to another, each device decrypts the packet using the network key, and authenticates the packet by verifying packet integrity. It then re-encrypts the packet with its own source address and frame counter values, and sends the message to the next hop. This process adds some overhead latency to unicast transmissions, but it helps prevent replay attacks. See chapter 5 for details. Maximum RF Payload Size XBee ZB firmware includes a command (ATNP) that returns the maximum number of RF payload bytes that can be sent in a unicast transmission. Querying the NP command, like most other commands, returns a HEXADECIMAL value. This number will change based on whether security is enabled or not. If security is enabled (EE command), the maximum number of RF payload bytes decreases since security requires additional overhead. After reading the NP value, the following conditions can affect the maximum number of data bytes in a single RF transmission:  -bit addresses in the source route are inserted into the RF payload space. For example, if NP returns 84 bytes, and a source route must traverse 3 intermediate hops (3 16-bit addresses); the total number of bytes that can be sent in one RF packet is 78.   payload bytes by 4. Throughput Throughput in a ZigBee network can vary by a number of variables, including: number of hops, encryption enabled/ disabled, sleeping end devices, failures/route discoveries. Our empirical testing showed the following throughput performance in a robust operating environment (low interference).  Data Throughput* configuration Data Throughput 1 hop, RR, SD 35Kbps 1 hop, RR, SE 19kBPS 1 hop, RE, SD 25Kbps 1 hop, RE, SE 16Kbps 1 hop, ER, SD 21Kbps 1 hop, ER, SE 16kKbps
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 76  4 hops, RR, SD 10Kpbs 4 hops, RR, SE 5Kbps  RR = router to router,  RE = router to end device (non-sleeping),  ER = end device (non-sleeping) to router,  SD = security disabled,  SE = security enabled.  4 hops = 5 nodes total,  3 intermediate router nodes  * Data throughput measurements were made setting the serial interface rate to 115200 bps, and measuring the time to send 100,000 bytes from source to destination. During the test, no route discoveries or failures occurred. ZDO Transmissions ZigBee defines a ZigBee Device Objects layer (ZDO) that can provide device and service discovery and network management capabilities. This layer is described below. ZigBee Device Objects (ZDO) The ZigBee Device Objects (ZDO) is supported to some extent on all ZigBee devices. The ZDO is an endpoint that implements services described in the ZigBee Device Profile in the ZigBee specification. Each service has an assigned cluster ID, and most service requests have an associated response. The following table describes some common ZDO services. Cluster Name Cluster ID Description Network Address Request 0x0000 Request a 16-bit address of the radio with a matching 64-bit address (required parameter). Active Endpoints Request 0x0005 Request a list of endpoints from a remote device. LQI request 0x0031 Request data from a neighbor table of a remote device. Routing Table Request 0x0032 Request to retrieve routing table entries from a remote device. Network Address Response 0x8000 Response that includes the 16-bit address of a device. Cluster Name Cluster ID Description LQI response 0x8031 Response that includes a neighbor table data from a remote device. Routing Table Response 0x8032 Response that includes routing table entry data from a remote device.
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 77   Refer to the ZigBee specification for a detailed description of all ZigBee Device Profile services. Sending a ZDO Command To send a ZDO command, an explicit transmit API frame must be used and formatted correctly. The source and destination endpoints must be set to 0, and the profile ID must be set to 0. The cluster ID must be set to match the cluster ID of the appropriate service. For example, to send an active endpoints request, the cluster ID must be set to 0x0005. The first byte of payload in the API frame is an application sequence number (transaction sequence number) that can be set to any single byte value. This same value will be used in the first byte of the ZDO response. All remaining payload bytes must be set as required by the ZDO. All multi-byte values must be sent in little endian byte order. Receiving ZDO Commands and Responses In XBee ZB firmware, ZDO commands can easily be sent using the API. In order to receive incoming ZDO commands, receiver application addressing must be enabled with the AO command. (See examples later in this section.) Not all incoming ZDO commands are passed up to the application. When a ZDO message is received on endpoint 0 and profile ID 0, the cluster ID indicates the type of ZDO message that was received. The first byte of payload is generally a sequence number that corresponds to a sequence number of a request. The remaining bytes are set as defined by the ZDO. Similar to a ZDO request, all multi-byte values in the response are in little endian byte order. Example 1: Send a ZDO LQI Request to read the neighbor table contents of a remote. Looking at the ZigBee specification, the cluster ID for an LQI Request is 0x0031, and the payload only requires a single byte (start index). This example will send an LQI request to a remote device with a 64-bit address of 0x0013A200 40401234. The start index will be set to 0, and the transaction sequence number will be set to 0x76 API Frame: 7E 0016 11 01 0013A200 40401234 FFFE 00 00 0031 0000 00 00 76 00 CE 0x0016 - length  0x11 - Explicit transmit request  0x01 - frame ID (set to a non-zero value to enable the transmit status message, or set to 0 to disable)  0x0013A200 40401234 - 64-bit address of the remote  0xFFFE - 16-bit address of the remote (0xFFFE = unknown). Optionally, set to the 16-bit address of the destination if known.  0x00 - Source endpoint  0x00 - Destination endpoint  0x0031 - Cluster ID (LQI Request, or Neighbor table request)  0x0000 - Profile ID (ZigBee Device Profile)  0x00 - Broadcast radius  0x00 - Tx Options  0x76 - Transaction sequence number  0x00 - Required payload for LQI request command
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 78  0xCE - Checksum (0xFF - SUM (all bytes after length)) Description: This API frame sends a ZDO LQI request (neighbor table request) to a remote device to obtain data from its neighbor table. Recall that the AO command must be set correctly on an API device to enable the explicit API receive frames in order to receive the ZDO response. Example 2: Send a ZDO Network Address Request to discover the 16-bit address of a remote. Looking at the ZigBee specification, the cluster ID for a network Address Request is 0x0000, and the payload only requires the following: [64-bit address] + [Request Type] + [Start Index] This example will send a Network Address Request as a broadcast transmission to discover the 16-bit address of the device with a 64-bit address of 0x0013A200 40401234. The request type and start index will be set to 0, and the transaction sequence number will be set to 0x44 API Frame: 7E 001F 11 01 00000000 0000FFFF FFFE 00 00 0000 0000 00 00 44 34124040 00A21300 00 00 33 0x001F  length 0x11 - Explicit transmit request  0x01 - frame ID (set to a non-zero value to enable the transmit status message, or set to 0 to disable)  0x00000000 0000FFFF - 64-bit address for a broadcast transmission  0xFFFE - Set to this value for a broadcast transmission.  0x00 - Source endpoint  0x00 - Destination endpoint  0x0000 - Cluster ID (Network Address Request)  0x0000 - Profile ID (ZigBee Device Profile)  0x00 - Broadcast radius  0x00 - Tx Options  0x44 - Transaction sequence number  0x34124040 00A21300 00 00 - Required payload for Network Address Request command  0x33 - Checksum (0xFF - SUM (all bytes after length)) Description: This API frame sends a broadcast ZDO Network Address Request to obtain the 16-bit address of a device with a 64-bit address of 0x0013A200 40401234. Note the bytes for the 64-bit address were inserted in little endian byte order. All multi-byte fields in the API payload of a ZDO command must have their data inserted in little endian byte order. Also recall that the AO command must be set correctly on an API device to enable the explicit API receive frames in order to receive the ZDO response. Transmission Timeouts The ZigBee stack includes two kinds of transmission timeouts, depending on the nature of the destination device. For destination devices such as routers whose receiver is always on, a unicast timeout is used. The unicast timeout estimates a timeout based on the number of unicast hops the packet should traverse to get data to the destination device. For transmissions destined for end devices, the ZigBee stack uses an extended timeout that includes the
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 79  unicast timeout (to route data to the end device's parent), and it includes a timeout for the end device to finish sleeping, wake, and poll the parent for data. The ZigBee stack includes some provisions for a device to detect if the destination is an end device or not. The ZigBee stack uses the unicast timeout unless it knows the destination is an end device. The XBee API includes a transmit options bit that can be set to specify if the extended timeout should be used for a given transmission. If this bit is set, the extended timeout will be used when sending RF data to the specified destination. To improve routing reliability, applications should set the extended timeout bit when sending data to end devices if: hich are end devices, AND   Equations for these timeouts are computed in the following sections. Note: The timeouts in this section are worst-case timeouts and should be padded by a few hundred milliseconds. These worst-case timeouts apply when an existing route breaks down (e.g. intermediate hop or destination device moved). Unicast Timeout The unicast timeout is settable with the NH command. The actual unicast timeout is computed as ((50 * NH) + 100). The default NH value is 30 which equates to a 1.6 second timeout. The unicast timeout includes 3 transmission attempts (1 attempt and 2 retries). The maximum total timeout is about: 3 * ((50 * NH) + 100). For example, if NH=30 (0x1E), the unicast timeout is about 3 * ((50 * 30) + 100), or  3 * (1500 + 100), or 3 * (1600), or  4800 ms, or  4.8 seconds. Extended Timeout The worst-case transmission timeout when sending data to an end device is somewhat larger than when transmitting to a router or coordinator. As described later in chapter 6, RF data packets are actually sent to the parent of the end device, who buffers the packet until the end device wakes to receive it. The parent will buffer an RF data packet for up to (1.2 * SP) time. To ensure the end device has adequate time to wake and receive the data, the extended transmission timeout to an end device is: (50 * NH) + (1.2 * SP) This timeout includes the packet buffering timeout (1.2 * SP) and time to account for routing through the mesh network (50 * NH). If an acknowledgment is not received within this time, the sender will resend the transmission up to two more times. With retries included, the longest transmission timeout when sending data to an end device is: 3 * ((50 * NH) + (1.2 * SP))
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 80  The SP value in both equations must be entered in millisecond units. (The SP command setting uses 10ms units and must be converted to milliseconds to be used in this equation.) For example, suppose a router is configured with NH=30 (0x1E) and SP=0x3E8 (10,000 ms), and that it is either trying to send data to one of its end device children, or to a remote end device. The total extended timeout to the end device is about: 3 * ((50 * NH) + (1.2 * SP)), or 3 * (1500 + 12000), or 3 * (13500), or 40500 ms, or 40.5 seconds. Transmission Examples Example 1: Send a unicast API data transmission to the coordinator using 64-bit address 0, with payload "TxData". API Frame: 7E 0014 10 01 00000000 00000000 FFFE 00 00 54 78 44 61 74 61 AB Field Composition: 0x0014 - length  0x10 - API ID (tx data)  0x01 - frame ID (set greater than 0 to enable the tx-status response)  0x00000000 00000000 - 64-bit address of coordinator (ZB definition)  0xFFFE - Required 16-bit address if sending data to 64-bit address of 0.  0x00 - Broadcast radius (0 = max hops)  0x00 - Tx options 0x54 78 44 61 74 61 - ASCII representation of "TxData" string  0xAB - Checksum (0xFF - SUM (all bytes after length)) Description: This transmission sends the string "TxData" to the coordinator, without knowing the coordinator device's 64-bit address. A 64-bit address of 0 is defined as the coordinator in ZB firmware. If the coordinator's 64-bit address was known, the 64-bit address of 0 could be replaced with the coordinator's 64-bit address, and the 16-bit address could be set to 0. Example 2 - Send a broadcast API data transmission that all devices can receive (including sleeping end devices), with payload "TxData". API Frame: 7E 0014 10 01 00000000 0000FFFF FFFE 00 00 54 78 44 61 74 61 AD Field Composition: 0x0014 - length  0x10 - API ID (tx data)  0x01 - frame ID (set to a non-zero value to enable the tx-status response)  0x00000000 0000FFFF - Broadcast definition (including sleeping end devices
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 81  0xFFFE - Required 16-bit address to send broadcast transmission.  0x00 - Broadcast radius (0 = max hops)  0x00 - Tx options 0x54 78 44 61 74 61 - ASCII representation of "TxData" string  0xAD - Checksum (0xFF - SUM (all bytes after length)) Description: This transmission sends the string "TxData" as a broadcast transmission. Since the destination address is set to 0xFFFF, all devices, including sleeping end devices can receive this broadcast. If receiver application addressing is enabled, the XBee will report all received data frames in the explicit format (0x91) to indicate the source and destination endpoints, cluster ID, and profile ID that each packet was received on. (Status messages like modem status and route record indicators are not affected.) To enable receiver application addressing, set the AO command to 1 using the AT command frame (0x08). Here's how to do this: API Frame: 7E 0005 08 01 414F 01 65 Field Composition: 0x0005 - length  0x08 - API ID (at command)  0x01 - frame ID (set to a non-zero value to enable AT command response frames)  0x414F - ASCII representation of 'A','O' (the command being issued) 0x01 - Parameter value  0x65 - Checksum (0xFF - SUM (all bytes after length)) Description: Setting AO=1 is required for the XBee to use the explicit receive API frame (0x91) when RF data packets are received. This is required if the application needs indication of source or destination endpoint, cluster ID, and/ or profile ID values used in received ZigBee data packets. ZDO messages can only be received if AO=1.
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 82  5. Security ZigBee supports various levels of security that can be configured depending on the needs of the application. Security provisions include: -bit AES encryption    ons to ensure message integrity, confidentiality, and authentication. The first half of this chapter describes various security features defined in the ZigBee-PRO specification, while the last half illustrates how the XBee and XBee-PRO modules can be configured to support these features Security Modes The ZigBee standard supports three security modes  residential, standard, and high security. Residential security was first supported in the ZigBee 2006 standard. This level of security requires a network key be shared among devices. Standard security adds a number of optional security enhancements over residential security, including an APS layer link key. High security adds entity authentication, and a number of other features not widely supported. XBee ZB modules primarily support standard security, although end devices that support residential security can join and interoperate with standard security devices. The remainder of this chapter focuses on material that is relevant to standard security. ZigBee Security Model ZigBee security is applied to the Network and APS layers. Packets are encrypted with 128-bit AES encryption. A network key and optional link key can be used to encrypt data. Only devices with the same keys are able to communicate together in a network. Routers and end devices that will communicate on a secure network must obtain the correct security keys. Network Layer Security The network key is used to encrypt the APS layer and application data. In addition to encrypting application messages, network security is also applied to route request and reply messages, APS commands, and ZDO commands. Network encryption is not applied to MAC layer transmissions such as beacon transmissions, etc. If security is enabled in a network, all data packets will be encrypted with the network key. Packets are encrypted and authenticated using 128-bit AES. This is shown in the figure below.
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 83  Frame Counter The network header of encrypted packets includes a 32-bit frame counter. Each device in the network maintains a 32-bit frame counter that is incremented for every transmission. In addition, devices track the last known 32- bit frame counter for each of its neighbors. If a device receives a packet from a neighbor with a smaller frame counter than it has previously seen, the packet is discarded. The frame counter is used to protect against replay attacks. If the frame counter reaches a maximum value of 0xFFFFFFFF, it does not wrap to 0 and no more transmissions can be sent. Due to the size of the frame counters, reaching the maximum value is a very unlikely event for most applications. The following table shows the required time under different conditions, for the frame counter to reach its maximum value. Average Transmission Rate Time until 32-bit frame counter expires 1/second 136 years 10/second 13.6 years  To clear the frame counters without compromising security, the network key can be changed in the network. When the network key is updated, the frame counters on all devices reset to 0. (See the Network Key Updates section for details.) Message Integrity code The network header, APS header, and application data are all authenticated with 128-bit AES. A hash is performed on these fields and is appended as a 4-byte message integrity code (MIC) to the end of the packet. The MIC allows receiving devices to ensure the message has not been changed. The MIC provides message integrity in the ZigBee he packet is dropped. Network Layer Encryption and Decryption Packets with network layer encryption are encrypted and decrypted by each hop in a route. When a device receives a packet with network encryption, it decrypts the packet and authenticates the packet. If the device is not the destination, it then encrypts and authenticates the packet, using its own frame counter and source address in the network header section. Since network encryption is performed at each hop, packet latency is slightly longer in an encrypted network than in a non-encrypted network. Also, security requires 18 bytes of overhead to include a 32-bit frame counter, an 8-byte source address, 4-byte MIC, and 2 other bytes. This reduces the number of payload bytes that can be sent in a data packet. Network Key Updates ZigBee supports a mechanism for changing the network key in a network. When the network key is changed, the frame counters in all devices reset to 0. APS Layer Security APS layer security can be used to encrypt application data using a key that is shared between source and destination devices. Where network layer security is applied to all data transmissions and is decrypted and re-encrypted on a hop-by-hop basis, APS security is optional and provides end-to-end security using an APS link key that only the source and destination device know. APS security can be applied on a packet-by-packet basis. APS security cannot be applied to broadcast transmissions. If APS security is enabled, packets are encrypted and authenticated using 128-bit AES. This is shown in the figure below:
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 84   Message Integrity Code If APS security is enabled, the APS header and data payload are authenticated with 128-bit AES. A hash is performed on these fields and appended as a 4-byte message integrity code (MIC) to the end of the packet. This MIC is different than the MIC appended by the network layer. The MIC allows the destination device to ensure the message has not been changed. If the destination device receives a packet and the MIC does not match the de APS Link Keys There are two kinds of APS link keys  trust center link keys and application link keys. A trust center link key is established between a device and the trust center, where an application link key is established between a device and another device in the network where neither device is the trust center. APS Layer Encryption and Decryption Packets with APS layer encryption are encrypted at the source and only decrypted by the destination. Since APS encryption requires a 5-byte header and a 4-byte MIC, the maximum data payload is reduced by 9 bytes when APS encryption is used. Network and APS Layer Encryption Network and APS layer encryption can both be applied to data. The following figure demonstrates the authentication and encryption performed on the final ZigBee packet when both are applied.
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 85   Trust Center ZigBee defines a trust center device that is responsible for authenticating devices that join the network. The trust center also manages link key distribution in the network. Forming and Joining a secure Network The coordinator is responsible for selecting a network encryption key. This key can either be preconfigured or randomly selected. In addition, the coordinator generally operates as a trust center and must therefore select the trust center link key. The trust center link key can also be preconfigured or randomly selected.  Devices that join the network must obtain the network key when they join. When a device joins a secure network, the network and link keys can be sent to the joining device. If the joining device has a pre-configured trust center link key, the network key will be sent to the joining device encrypted by the link key. Otherwise, if the joining device is not pre-configured with the link key, the device could only join the network if the network key is sent joining devices that are not pre-configured with the link key. Sending the network key unencrypted is not recommended as it can open a security hole in the network. To maximize security, devices should be pre-configured with the correct link key. Implementing Security on the XBee If security is enabled in the XBee ZB firmware, devices acquire the network key when they join a network. Data transmissions are always encrypted with the network key, and can optionally be end-to-end encrypted with the APS link key. The following sections discuss the security settings and options in the XBee ZB firmware. Enabling Security To enable security on a device, the EE command must be set to 1. If the EE command value is changed and changes are applied (e.g. AC command), the XBee module will leave the network (PAN ID and channel) it was operating on, and attempt to form or join a new network.
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 86  If EE is set to 1, all data transmissions will be encrypted with the network key. When security is enabled, the maximum number of bytes in a single RF transmission will be reduced. See the NP command for details. Note: The EE command must be set the same on all devices in a network. Changes to the EE command should be written to non-volatile memory (to be preserved through power cycle or reset events) using the WR command. Setting the Network Security Key The coordinator must select the network security key for the network. The NK command (write-only) is used to set the network key. If NK=0 (default), a random network key will be selected. (This should suffice for most applications.) Otherwise, if NK is set to a non-zero value, the network security key will use the value specified by NK. NK is only supported on the coordinator. Routers and end devices with security enabled (ATEE=1) acquire the network key when they join a network. They will receive the network key encrypted with the link key if they share a pre-configured link key with the coordinator. See the following section for details. Setting the APS Trust Center Link Key The coordinator must also select the trust center link key, using the KY command. If KY=0 (default), the coordinator will select a random trust center link key (not recommended). Otherwise, if KY is set greater than 0, this value will be used as the pre-configured trust center link key. KY is write-only and cannot be read. Note: Application link keys (sent between two devices where neither device is the coordinator) are not supported in ZB firmware at this time. Random Trust Center Link Keys If the coordinator selects a random trust center link key (KY=0, default), then it will allow devices to join the network without having a pre-configured link key. However, this will cause the network key to be sent unencrypted over-the-air to joining devices and is not recommended. Pre-configured Trust Center Link Keys If the coordinator uses a pre-configured link key (KY > 0), then the coordinator will not send the network key unencrypted to joining devices. Only devices with the correct pre-configured link key will be able to join and communicate on the network. Enabling APS Encryption APS encryption is an optional layer of security that uses the link key to encrypt the data payload. Unlike network encryption that is decrypted and encrypted on a hop-by-hop basis, APS encryption is only decrypted by the destination device. The XBee must be configured with security enabled (EE set to 1) to use APS encryption.  APS encryption can be enabled in API firmware on a per-packet basis. To enable APS encryption for a given transmission, the "enable APS encryption" transmit options bit should be set in the API transmit frame. Enabling APS encryption decreases the maximum payload size by 9 bytes. Using a Trust Center The EO command can be used to define the coordinator as a trust center. If the coordinator is a trust center, it will be alerted to all new join attempts in the network. The trust center also has the ability to update or change the network key on the network. In ZB firmware, a secure network can be established with or without a trust center. Network and APS layer encryption are supported if a trust center is used or not.   Updating the Network Key with a Trust Center If the trust center has started a network and the NK value is changed, the coordinator will update the network key on all devices in the network. (Changes to NK will not force the device to leave the network.) The network will
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 87  continue to operate on the same channel and PAN ID, but the devices in the network will update their network key, increment their network key sequence number, and restore their frame counters to 0.   Updating the Network Key without a Trust Center If the coordinator is not running as a trust center, the network reset command (NR1) can be used to force all devices in the network to leave the current network and rejoin the network on another channel. When devices leave and reform then network, the frame counters are reset to 0. This approach will cause the coordinator to form a new network that the remaining devices should join. Resetting the network in this manner will bring the coordinator and routers in the network down for about 10 seconds, and will likely cause the 16-bit PAN ID and 16-bit addresses of the devices to change. XBee Security Examples This section covers some sample XBee configurations to support different security modes. Several AT commands are listed with suggested parameter values. The notation in this section includes an '=' sign to indicate what each command register should be set to - for example, EE=1. This is not the correct notation for setting command values in the XBee. In AT command mode, each command is issued with a leading 'AT' and no '=' sign - for example ATEE1. In the API, the two byte command is used in the command field, and parameters are populated as binary values in the parameter field. Example 1: Forming a network with security (pre-configured link keys) 1. Start a coordinator with the following settings:  a. ID=2234 (arbitrarily selected)  b. EE=1  c. NK=0  d. KY=4455  e. WR (save networking parameters to preserve them through power cycle)  2. Configure one or more routers or end devices with the following settings:  a. ID=2234  b. EE=1  c. KY=4455  d. WR (save networking parameters to preserve them through power cycle)  network). In this example, EE, ID, and KY are set the same on all devices. After successfully joining the secure network, all application data transmissions will be encrypted by the network key. Since NK was set to 0 on the coordinator, a random network key was selected. And since the link key (KY) was configured the same on all devices, to a non-zero value, the network key was sent encrypted by the pre-configured link key (KY) when the devices joined. Example 1: Forming a network with security (obtaining keys during joining) 1. Start a coordinator with the following settings:  a. ID=2235  b. EE=1  c. NK=0  d. KY=0
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 88  e. WR (save networking parameters to preserve them through power cycle)  2. Configure one or more routers or end devices with the following settings:  a. ID=2235  b. EE=1  c. KY=0  d. WR (save networking parameters to preserve them through power cycle)  3. Read the AI setting on the coordinator and joining devices until they return 0 (formed or joined a network). In this example, EE, ID, and KY are set the same on all devices. Since NK was set to 0 on the coordinator, a random network key was selected. And since KY was set to 0 on all devices, the network key was sent unencrypted ("in the clear") when the devices joined. This approach introduces security vulnerability into the network and is not recommended.
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 89  6. Network Commissioning and Diagnostics Network commissioning is the process whereby devices in a mesh network are discovered and configured for operation. The XBee modules include several features to support device discovery and configuration. In addition to configuring devices, a strategy must be developed to place devices to ensure reliable routes. To accommodate these requirements, the XBee modules include various features to aid in device placement, configuration, and network diagnostics. Device Configuration XBee/XBee-PRO ZB modules can be configured locally through serial commands (AT or API), or remotely through remote API commands. API devices can send configuration commands to set or read the configuration settings of any device in the network. Device Placement For a mesh network installation to be successful, the installer must be able to determine where to place individual XBee devices to establish reliable links throughout the mesh network. Link Testing A good way to measure the performance of a mesh network is to send unicast data through the network from one device to another to determine the success rate of many transmissions. To simplify link testing, the modules support a loopback cluster ID (0x12) on the data endpoint (0xE8). Any data sent to this cluster ID on the data endpoint will be transmitted back to the sender. This is shown in the figure below:  The configuration steps to send data to the loopback cluster ID depend on the firmware type.   AT Firmware To send data to the loopback cluster ID on the data endpoint of a remote device, set the CI command value to 0x12. The SE and DE commands should be set to 0xE8 (default value). The DH and DL commands should be set to the address of the remote (0 for the coordinator, or the 64-bit address of the remote). After exiting command mode, any received serial characters will be transmitted to the remote device, and returned to the sender.   API Firmware
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 90  Send an Explicit Addressing ZigBee Command API frame (0x11) using 0x12 as the cluster ID and 0xE8 as the source and destination endpoint. Data packets received by the remote will be echoed back to the sender. RSSI Indicators It is possible to measure the received signal strength on a device using the DB command. DB returns the RSSI value (measured in dBm) of the last received packet. However, this number can be misleading. The DB value only indicates the received signal strength of the last hop. If a transmission spans multiple hops, the DB value provides no indication of the overall transmission path, or the quality of the worst link  it only indicates the quality of the last link and should be used sparingly. The DB value can be determined in hardware using the RSSI/PWM module pin (pin 6). If the RSSI PWM functionality is enabled (P0 command), when the module receives data, the RSSI PWM is set to a value based on the RSSI of the received packet. (Again, this value only indicates the quality of the last hop.) This pin could potentially be connected to an LED to indicate if the link is stable or not. Device Discovery Network Discovery The network discovery command can be used to discover all Digi modules that have joined a network. Issuing the ND command sends a broadcast node discovery command throughout the network. All devices that receive the command), and other relevant information. This command is useful for generating a list of all module addresses in a network. When a device receives the node discovery command, it waits a random time before sending its own response. The maximum time delay is set on the ND sender with the NT command. The ND originator includes its NT setting in the transmission to provide a delay window for all devices in the network. Large networks may need to increase NT to improve network discovery reliability. The default NT value is 0x3C (6 seconds). ZDO Discovery The ZigBee Device Profile includes provisions to discover devices in a network that are supported on all ZigBee devices (including non-Digi products). These include the LQI Request (cluster ID 0x0031) and the Network Update Request (cluster ID 0x0038). The LQI Request can be used to read the devices in the neighbor table of a remote device, and the Network Update Request can be used to have a remote device do an active scan to discover all nearby ZigBee devices. Both of these ZDO commands can be sent using the XBee Explicit API transmit frame (0x11). See the API chapter for details. Refer to the ZigBee specification for formatting details of these two ZDO frames. Joining Announce All ZigBee devices send a ZDO Device Announce broadcast transmission when they join a ZigBee network (ZDO cluster ID 0x0013). These frames will be sent out the XBee's UART as an Explicit Rx Indicator API frame (0x91) if AO is set to 1. The device announce payload includes the following information: [Sequence Number] + [16-bit address] + [64-bit address] + [Capability] The 16-bit and 64-bit addresses are received in little-endian byte order (LSB first). See the ZigBee specification for details. Commissioning Pushbutton and Associate LED The XBee modules support a set of commissioning and LED behaviors to aid in device deployment and commissioning. These include the commissioning pushbutton definitions and associate LED behaviors. These features can be supported in hardware as shown below. Commissioning Pushbutton and Associate LED Functionalities
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 91    Commissioning Pushbutton The commissioning pushbutton definitions provide a variety of simple functions to aid in deploying devices in a network. The commissioning button functionality on pin 20 is enabled by setting the D0 command to 1 (enabled by default). Button Presses If modules is joined to a network If module is not joined to a network 1 broadcast transmission seconds                                                         the Associate pin indicating the cause of join failure (see section 6.4.2). 2 transmission to enable joining on the coordinator and all devices in the network for 1 minute. (If joining is permanently enabled on a device (NJ = 0xFF), this action has no effect on that device.)  4  Issues ATRE to restore module   parameters to default values, including ID and SC.                                                                            based on its ID and SC settings.  module parameters to default values, including ID and SC.                                           network based on its ID and SC settings.  Button presses may be simulated in software using the ATCB command. ATCB should be issued with a parameter set to the number of button presses to execute. (e.g. sending ATCB1 will execute the action(s) associated with a single button press.) The node identification frame is similar to the node discovery response frame  it contains thnode identifier string (NI command), and other relevant data. All API devices that receive the node identification frame send it out their UART as an API Node Identification Indicator frame (0x95). Associate LDE
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 92  The Associate pin (pin 1take advantage of these indications, an LED can be connected to the Associate pin as shown in the figure above. The Associate LED functionality is enabled by setting the D5 command to 1 (enabled by default). If enabled, the Associate pin is configured as an output and will behave as described in the following sections. Joined Indication The Associate pin indicates the network status of a device. If the module is not joined to a network, the Associate pin is set high. Once the module successfully joins a network, the Associate pin blinks at a regular time interval. This is shown in the following figure.  The LT command defines the blink time of the Associate pin. If set to 0, the device uses the default blink time (500ms for coordinator, 250ms for routers and end devices). Diagnostics Support The Associate pin works with the commissioning pushbutton to provide additional diagnostics behaviors to aid in deploying and testing a network. If the commissioning push button is pressed once, and the device has not joined a network, the Associate pin blinks a numeric error code to indicate the cause of join failure. The number of blinks is equal to (AI value  0x20). For example, if AI=0x22, 2 blinks occur. If the commissioning push button is pressed once, and the device has joined a network, the device transmits a broadcast node identification packet. If the Associate LED functionality is enabled (D5 command), a device that receives this transmission will blink its Associate pin rapidly for 1 second. The following figures demonstrate these behaviors.
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 93
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 94  7. Managing End Devices ZigBee end devices are intended to be battery-powered devices capable of sleeping for extended periods of time. Since end devices may not be awake to receive RF data at a given time, routers and coordinators are equipped with additional capabilities (including packet buffering and extended transmission timeouts) to ensure reliable data delivery to end devices. End Device Operation When an end device joins a ZigBee network, it must find a router or coordinator device that is allowing end devices to join. Once the end device joins a network, a parent-child relationship is formed between the end device and the router or coordinator that allowed it to join. See chapter 3 for details. When the end device is awake, it sends poll request messages to its parent. When the parent receives a poll request, it checks a packet queue to see if it has any buffered messages for the end device. It then sends a MAC layer acknowledgment back to the end device that indicates if it has data to send to the end device or not.   If the end device receives the acknowledgment and finds that the parent has no data for it, the end device can return to idle mode or sleep. Otherwise, it will remain awake to receive the data. This polling mechanism allows the end device to enter idle mode and turn its receiver off when RF data is not expected in order to reduce current consumption and conserve battery life. The end device can only send data directly to its parent. If an end device must send a broadcast or a unicast transmission to other devices in the network, it sends the message directly to its parent and the parent performs any necessary route or address discoveries to route the packet to the final destination. Parent Operation Each router or coordinator maintains a child table that contains the addresses of its end device children. A router or coordinator that has unused entries in its child table is said to have end device capacity, or the ability to allow new end devices to join. If the child table is completely filled (such that the number of its end device children matches the number of child table entries), the device cannot allow any more end devices to join to it. Since the end device children are not guaranteed to be awake at a given time, the parent is responsible for managing incoming data packets in behalf of its end device children. If a parent receives an RF data transmission
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 95  destined for one of its end device children, and if the parent has enough unused buffer space, it will buffer the packet. The data packet will remain buffered until a timeout expires, or until the end device sends a poll request to retrieve the data. The parent can buffer one broadcast transmission for all of its end device children. When a broadcast transmission is received and buffered, the parent sets a flag in its child table when each child polls and retrieves the packet. Once all children have received the broadcast packet, the buffered broadcast packet is discarded. If all children have not received a buffered broadcast packet and a new broadcast is received, the old broadcast packet is discarded, the child table flags are cleared, and the new broadcast packet is buffered for the end device children. This is demonstrated in the figure below.  When an end device sends data to its parent that is destined for a remote device in the network, the parent buffers the data packet until it can establish a route to the destination. The parent may perform a route or 16-bit address discovery in behalf of its end device children. Once a route is established, the parent sends the data transmission to the remote device. End Device Poll Timeouts To better support mobile end devices (end devices that can move around in a network); parent router and coordinator devices have a poll timeout for each end device child. If an end device does not send a poll request to its parent within the poll timeout, the parent will remove the end device from its child table. This allows the child table on a router or coordinator to better accommodate mobile end devices in the network. Packet Buffer Usage Packet buffer usage on a router or coordinator varies depending on the application. The following activities can require use of packet buffers for up to several seconds:     transmissions (buffered until acknowledgment is received from destination or retries exhausted)   Applications that use regular broadcasting or that require regular address or route discoveries will use up a significant number of buffers, reducing the buffer availability for managing packets for end device children. Applications should reduce the number of required application broadcasts, and consider implementing an external address table or many-to-one and source routing if necessary to improve routing efficiency. Non-Parent Device Operation Devices in the ZigBee network treat data transmissions to end devices differently than transmissions to other routers and coordinators. Recall that when a unicast transmission is sent, if a network acknowledgment is not received within a timeout, the device resends the transmission. When transmitting data to remote coordinator or
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 96  router devices, the transmission timeout is relatively short since these devices are powered and responsive. However, since end devices may sleep for some time, unicast transmissions to end devices use an extended timeout mechanism in order to allow enough time for the end device to wake and receive the data transmission from its parent. If a non-parent device does not know the destination is an end device, it will use the standard unicast timeout for the transmission. However, provisions exist in the Ember ZigBee stack for the parent to inform the message sender that the destination is an end device. Once the sender discovers the destination device is an end device, future transmissions will use the extended timeout. See the XBee Router / Coordinator Configuration section in this chapter for details. XBee End Device Configuration XBee end devices support two different sleep modes:   Pin sleep allows an external microcontroller to determine when the XBee should sleep and when it should wake by controlling the Sleep_RQ pin. In contrast, cyclic sleep allows the sleep period and wake times to be configured through the use of AT commands. The sleep mode is configurable with the SM command. In both pin and cyclic sleep modes, XBee end devices poll their parent every 100ms while they are awake to retrieve buffered data. When a poll request has been sent, the end device enables the receiver until an acknowledgment is received from the parent. (It generally takes less than 10ms from the time the poll request is sent until the acknowledgment is received.) The acknowledgment indicates if the parent has buffered data for the end device child or not. If the acknowledgment indicates the parent has pending data, the end device will leave the receiver on to receive the data. Otherwise, the end device will turn off the receiver and enter idle mode (until the next poll request is sent) to reduce current consumption (and improve battery life). Once the module enters sleep mode, the On/Sleep pin (pin 26) is de-asserted (low) to indicate the module is entering sleep mode. If CTS hardware flow control is enabled (D7 command), the CTS pin (pin 25) is de-asserted (high) when entering sleep to indicate that serial data should not be sent to the module. The module will not respond to serial or RF data when it is sleeping. Applications that must communicate serially to sleeping end devices are encouraged to observe CTS flow control. When the XBee wakes from sleep, the On/Sleep pin is asserted (high), and if flow control is enabled, the CTS pin is also asserted (low). If the module has not joined a network, it will scan all SC channels after waking to try and find a valid network to join. Pin Sleep Pin sleep allows the module to sleep and wake according to the state of the Sleep_RQ pin (pin 9). Pin sleep mode is enabled by setting the SM command to 1. When Sleep_RQ is asserted (high), the module will finish any transmit or receive operations and enter a low power state. For example, if the module has not joined a network and Sleep_RQ is asserted (high), the module will sleep once the current join attempt completes (i.e. when scanning for a valid network completes). The module will wake from pin sleep when the Sleep_RQ pin is de-asserted (low).
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 97    In the figure above, t1, t2, and t3 represent the following events: - Time when Sleep_RQ is asserted (high)  - Time when the XBee enters sleep (CTS state change only if hardware flow control is enabled)  - Time when Sleep_RQ is de-asserted (low) and the module wakes. The time between T1 and T2 varies depending on the state of the module. In the worst case scenario, if the end device is trying to join a network, or if it is waiting for an acknowledgment from a data transmission, the delay could be up to a few seconds. When the XBee is awake and is joined to a network, it sends a poll request to its parent to see if the parent has any buffered data for it. The end device will continue to send poll requests every 100ms while it is awake.
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 98  Demonstration of Pin Sleep   Parent and remote devices must be configured to buffer data correctly and to utilize adequate transmission timeouts. See the XBee Router / Coordinator Configuration section in this chapter for details. Cyclic Sleep Cyclic sleep allows the module to sleep for a specified time and wake for a short time to poll its parent for any buffered data messages before returning to sleep again. Cyclic sleep mode is enabled by setting the SM command to 4 or 5. SM5 is a slight variation of SM4 that allows the module to be woken prematurely by asserting the Sleep_RQ pin (pin 10). In SM5, the XBee can wake after the sleep period expires, or if a high-to-low transition occurs on the Sleep_RQ pin. Setting SM to 4 disables the pin wake option. In cyclic sleep, the module sleeps for a specified time, and then wakes and sends a poll request to its parent to discover if the parent has any pending data for the end device. If the parent has buffered data for the end device, or if serial data is received, the XBee will remain awake for a time. Otherwise, it will enter sleep mode immediately. The On/Sleep line is asserted (high) when the module wakes, and is de-asserted (low) when the module sleeps. If hardware flow control is enabled (D7 command), the CTS pin will assert (low) when the module wakes and can receive serial data, and de-assert (high) when the module sleeps.
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 99    In the figure above, t1, t2, and t3 represent the following events: - Time when the module wakes from cyclic sleep  - Time when the module returns to sleep  - Later time when the module wakes from cyclic sleep. The wake time and sleep time are configurable with software commands as described in the sections below.   Wake Time (Until Sleep) In cyclic sleep mode (SM=4 or 5), if serial or RF data is received, the module will start a sleep timer (time until sleep). Any data received serially or over the RF link will restart the timer. The sleep timer value is settable with the ST command. While the module is awake, it will send poll request transmissions every 100ms to check its parent for buffered data messages. The module returns to sleep when the sleep timer expires, or if the SI command is sent to it. The following image shows this behavior.
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 100     Sleep Period The sleep period is configured based on the SP, SN, and SO commands. The following table lists the behavior of these commands. Command Range Description SP 0x20-oxAF0 (x10ms) Configures the sleep period of the module. SN 1-0xFFFF Configures the number of sleep periods multiplier. SD 0-0xFF Defines options for sleep mode behavior.  0x02 - Always wake for full ST time                          0X04-Enable extended sleep (sleep for full SP*SN) time)  The XBee module supports both a short cyclic sleep and an extended cyclic sleep that make use of these commands. These two modes allow the sleep period to be configured according to the application requirements.   Short Cyclic Sleep In short cyclic sleep mode, the sleep behavior of the module is defined by the SP and SN commands, and the SO command must be set to 0x00 (default) or 0x02. In short cyclic sleep mode, the SP command defines the sleep period and is settable up to 28 seconds. When the XBee enters short cyclic sleep, it remains in a low power state until the SP time has expired. After the sleep period expires, the XBee sends a poll request transmission to its parent to determine if its parent has any buffered data waiting for the end device. Since router and coordinator devices can buffer data for end device children up to 30 seconds, the SP range (up to 28 seconds) allows the end device to poll regularly enough to receive buffered data. If the parent has data for the end device, the end device will start its sleep timer (ST) and continue polling every 100ms to receive data. If the end device wakes and finds that its parent has no data for it, the end device can return to sleep immediately. The SN command can be used to control when the On/Sleep line is asserted (high). If SN is set to 1 (default), the On/Sleep line will be set high each time the XBee wakes from sleep. Otherwise, if SN is greater than 1, the On/Sleep line will only be set high if RF data is received, or after SN wake cycles occur. This allows an external device to remain powered off until RF data is received, or until a number of sleep periods have expired (SN sleep periods). This mechanism allows the XBee to wake at regular intervals to poll its parent for data without waking an external device for an extended time (SP * SN time). This is shown in the figure below.
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 101   Note: SP controls the packet buffer time on routers and coordinators. SP should be set on all router and coordinator devices to match the longest end device SP time. See the XBee Router / Coordinator Configuration section for details.   Extended Cyclic Sleep In extended cyclic sleep operation, an end device can sleep for a multiple of SP time which can extend the sleep time up to several days. The sleep period is configured using the SP and SN commands. The total sleep period is equal to (SP * SN) where SP is measured in 10ms units. The SO command must be set correctly to enable extended sleep. Since routers and coordinators can only buffer incoming RF data for their end device children for up to 30 seconds, if an end device sleeps longer than 30 seconds, devices in the network need some indication when an end device is awake before they can send data to it. End devices that use extended cyclic sleep should send a transmission (such as an IO sample) when they wake to inform other devices that they are awake and can receive data. It is recommended that extended sleep end devices set SO to wake for the full ST time in order to provide other devices with enough time to send messages to the end device. Similar to short cyclic sleep, end devices running in this mode will return to sleep when the sleep timer expires, or when the SI command is received. Transmitting RF Data An end device may transmit data when it wakes from sleep and has joined a network. End devices transmit directly to their parent and then wait for an acknowledgment to be received. The parent will perform any required address and route discoveries to help ensure the packet reaches the intended destination before reporting the transmission status to the end device. Receiving RF Data After waking from sleep, an end device sends a poll request to its parent to determine if the parent has any buffered data for it. In pin sleep mode, the end device polls every 100ms while the Sleep_RQ pin is de-asserted (low). In cyclic sleep mode, the end device will only poll once before returning to sleep unless the sleep timer (ST) is started (serial or RF data is received). If the sleep timer is started, the end device will continue to poll every 100ms until the sleep timer expires.
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 102  The XBee ZB 2x6x firmware includes an adaptive polling enhancement where, if an end device receives RF data from its parent, it sends another poll after a very short delay to check for more data. The end device continues to poll at a faster rate as long as it receives data from its parent. This feature greatly improves data throughput to end devices. When the end device no longer receives data from its parent, it resumes polling every 100ms. IO Sampling End devices can be configured to send one or more IO samples when they wake from sleep. To enable IO sampling on an end device, the IR command must be set to a non-zero value, and at least one analog or digital IO pin must be enabled for sampling (D0 - D9, P0-P2 commands). If IO sampling is enabled, an end device sends an IO sample when it wakes and starts the ST timer. It will continue sampling at the IR rate until the sleep timer (ST) has expired. See chapter 8 for details. Waking End Devices with the Commissioning Pushbutton If the commissioning pushbutton functionality is enabled (D0 command), a high-to-low transition on the AD0/ DIO0 pin (pin 33) will cause an end device to wake for 30 seconds. See the Commissioning Pushbutton section in chapter 7 for details. Parent Verification Since an end device relies on its parent to maintain connectivity with other devices in the network, XBee end devices include provisions to verify its connection with its parent. End devices monitor their link with their parent when sending poll messages and after a power cycle or reset event as described below. When an end device wakes from sleep, it sends a poll request to its parent. In cyclic sleep, if RF or serial data is not received and the sleep timer is not started, the end device polls one time and returns to sleep for another sleep period. Otherwise, the end device continues polling every 100ms. If the parent does not send an acknowledgment response to three consecutive poll request transmissions, the end device assumes the parent is out of range, and attempts to find a new parent. After a power-up or reset event, the end device does an orphan scan to locate its parent. If the parent does not send a response to the orphan scan, the end device attempts to find a new parent. Rejoining Once all devices have joined a ZigBee network, the permit-joining attribute should be disabled such that new devices are no longer allowed to join the network. Permit-joining can be enabled later as needed for short times. This provides some protection in preventing other devices from joining a live network. If an end device cannot communicate with its parent, the end device must be able to join a new parent to maintain network connectivity. However, if permit-joining is disabled in the network, the end device will not find a device that is allowing new joins. To overcome this problem, ZigBee supports rejoining, where an end device can obtain a new parent in the same network even if joining is not enabled. When an end device joins using rejoining, it performs a PAN ID scan to discover nearby networks. If a network is discovered that has the same 64-bit PAN ID as the end device, it will join the network by sending a rejoin request to one of the discovered devices. The device that receives the rejoin request will send a rejoin response if it can allow the device to join the network (i.e. child table not full). The rejoin mechanism can be used to allow a device to join the same network even if permit-joining is disabled. To enable rejoining, NJ should be set less than 0xFF on the device that will join. If NJ < 0xFF, the device assumes the network is not allowing joining and first tries to join a network using rejoining. If multiple rejoining attempts fail, or if NJ=0xFF, the device will attempt to join using association. XBee Router/Coordinator Configuration XBee routers and coordinators may require some configuration to ensure the following are set correctly:
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 103     The value of these timeouts depends on the sleep time used by the end devices. Each of these timeouts is discussed below. RF Packet Buffering Timeout When a router or coordinator receives an RF data packet intended for one of its end device children, it buffers the packet until the end device wakes and polls for the data, or until a packet buffering timeout occurs. This timeout is settable using the SP command. The actual timeout is (1.2 * SP), with a minimum timeout of 1.2 seconds and a maximum of 30 seconds. Since the packet buffering timeout is set slightly larger than the SP setting, SP should be set the same on routers and coordinators as it is on cyclic sleep end devices. For pin sleep devices, SP should be set as long as the pin sleep device can sleep, up to 30 seconds. Note: In pin sleep and extended cyclic sleep, end devices can sleep longer than 30 seconds. If end devices sleep longer than 30 seconds, parent and non-parent devices must know when the end device is awake in order to reliably send data. For applications that require sleeping longer than 30 seconds, end devices should transmit an IO sample or other data when they wake to alert other devices that they can send data to the end device. Child Poll Timeout Router and coordinator devices maintain a timestamp for each end device child indicating when the end device sent its last poll request to check for buffered data packets. If an end device does not send a poll request to its parent for a certain period of time, the parent will assume the end device has moved out of range and will remove the end device from its child table. This allows routers and coordinators to be responsive to changing network conditions. The NC command can be issued at any time to read the number of remaining (unused) child table entries on a router or coordinator. The child poll timeout is settable with the SP and SN commands. SP and SN should be set such that SP * SN matches the longest expected sleep time of any end devices in the network. The actual timeout is calculated as (3 * SP * SN), with a minimum of 5 seconds. For networks consisting of pin sleep end devices, the SP and SN values on the coordinator and routers should be set such that SP * SN matches the longest expected sleep period of any pin sleep device. The 3 multiplier ensures the end device will not be removed unless 3 sleep cycles pass without receiving a poll request. The poll timeout is settable up to a couple of months. Transmission Timeout As mentioned in chapter 4, when sending RF data to a remote router, since routers are always on, the timeout is based on the number of hops the transmission may traverse. This timeout it settable using the NH command. (See chapter 4 for details.) Since end devices may sleep for lengthy periods of time, the transmission timeout to end devices also includes some allowance for the sleep period of the end device. When sending data to a remote end device, the transmission timeout is calculated using the SP and NH commands. If the timeout occurs and an acknowledgment has not been received, the source device will resend the transmission until an acknowledgment is received, up to two more times. The transmission timeout per attempt is: 3 * ((unicast router timeout) + (end device sleep time)), or 3 * ((50 * NH) + (1.2 * SP)), where SP is measured in 10ms units. Putting it all Together Short Sleep Periods
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 104  Pin and cyclic sleep devices that sleep less than 30 seconds can receive data transmissions at any time since their parent device(s) will be able to buffer data long enough for the end devices to wake and poll to receive the data. SP should be set the same on all devices in the network. If end devices in a network have more than one SP setting, SP on the routers and coordinators should be set to match the largest SP setting of any end device. This will ensure the RF packet buffering, poll timeout, and transmission timeouts are set correctly. Extended Sleep Periods Pin and cyclic sleep devices that might sleep longer than 30 seconds cannot receive data transmissions reliably unless certain design approaches are taken. Specifically, the end devices should use IO sampling or another mechanism to transmit data when they wake to inform the network they can receive data. SP and SN should be set on routers and coordinators such that (SP * SN) matches the longest expected sleep time. This configures the poll timeout so end devices are not expired from the child table unless a poll request is not received for 3 consecutive sleep periods. As a general rule of thumb, SP and SN should be set the same on all devices in almost all cases. Sleep Examples This section covers some sample XBee configurations to support different sleep modes. Several AT commands are listed with suggested parameter values. The notation in this section includes an '=' sign to indicate what each command register should be set to - for example, SM=4. This is not the correct notation for setting command values in the XBee. In AT command mode, each command is issued with a leading 'AT' and no '=' sign - for example ATSM4. In the API, the two byte command is used in the command field, and parameters are populated as binary values in the parameter field. Example 1 Configure a device to sleep for 20 seconds, but set SN such that the On/Sleep line will remain deasserted for up to 1 minute. The following settings should be configured on the end device. SM = 4 (cyclic sleep) or 5 (cyclic sleep, pin wake)  SP = 0x7D0 (2000 decimal). This causes the end device to sleep for 20 seconds since SP is measured in units of 10ms.  SN = 3. (With this setting, the On/Sleep pin will assert once every 3 sleep cycles, or when RF data is received)  SO = 0 All router and coordinator devices on the network should set SP to match SP on the end device. This ensures that RF packet buffering times and transmission timeouts will be set correctly. Since the end device wakes after each sleep period (ATSP), the SN command can be set to 1 on all routers and the coordinator. Example 2 Configure an end device to sleep for 20 seconds, send 4 IO samples in 2 seconds, and return to sleep. Since SP is measured in 10ms units, and ST and IR are measured in 1ms units, configure an end device with the following settings: SM = 4 (cyclic sleep) or 5 (cyclic sleep, pin wake)  SP = 0x7D0 (2000 decimal). This causes the end device to sleep for 20 seconds.  SN = 1  SO = 0
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 105  ST = 0x7D0 (2000 decimal). This sets the sleep timer to 2 seconds.  IR = 0x258 (600 decimal). Set IR to a value greater than (2 seconds / 4) to get 4 samples in 2 seconds. The end device sends an IO sample at the IR rate until the sleep timer has expired. At least one analog or digital IO line must be enabled for IO sampling to work. To enable pin 19 (AD1/DIO1) as a digital input line, the following must be set: D1 = 3 All router and coordinator devices on the network should set SP to match SP on the end device. This ensures that RF packet buffering times and transmission timeouts will be set correctly. Example 3 Configure a device for extended sleep: to sleep for 4 minutes. SP and SN must be set such that SP * SN = 4 minutes. Since SP is measured in 10ms units, the following settings can be used to obtain 4 minute sleep. SM = 4 (cyclic sleep) or 5 (cyclic sleep, pin wake)  SP = 0x7D0 (2000 decimal, or 20 seconds)  SN = 0x0B (12 decimal)  SO = 0x04 (enable extended sleep) With these settings, the module will sleep for SP * SN time, or (20 seconds * 12) = 240 seconds = 4 minutes. For best results, the end device should send a transmission when it wakes to inform the coordinator (or network) when it wakes. It should also remain awake for a short time to allow devices to send data to it. The following are recommended settings. ST = 0x7D0 (2 second wake time)  SO = 0x06 (enable extended sleep and wake for ST time)  IR = 0x800 (send 1 IO sample after waking). At least one analog or digital IO sample should be enabled for IO sampling. With these settings, the end device will wake after 4 minutes and send 1 IO sample. It will then remain awake for 2 seconds before returning to sleep. SP and SN should be set to the same values on all routers and coordinators that could allow the end device to join. This will ensure the parent does not timeout the end device from its child table too quickly. The SI command can optionally be sent to the end device to cause it to sleep before the sleep timer expires.
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 106  8. XBee Analog and Digital IO Lines XBee ZB firmware supports a number of analog and digital IO pins that are configured through software commands. Analog and digital IO lines can be set or queried. The following table lists the configurable IO pins and the corresponding configuration commands. Pin name(s) Module pin AT cmd  Command Range Dout/DIO13 3 P3 0, 3-5 DIN/nConfig/DIO14 4 P4   PWM RSSI/DIO10 7 P0 0,1, 3-5 PWM1/ DIO11 8 P1 0, 3-5 DTR/Slp_Rq/DIO8 10 D8 0, 3-5 PTI_DATA/SPI_nAttn/ADC5/DIO19 12 P9 0,1,6 SPI_SClk/DIO18 14 P8 0,1 SPI_nSSel/DIO17 15 P7 0,1 Spi_MOSI/DIO16 16 P6 0,1 Spi_MISO/DIO15 17 P5 0,1 JTMS/SWDIO/DIO12/CD 21 P2 0,3-5 JTRst/DIO4 24 D4 0, 3-5 nCTS/DIO7 25 D7 0,1, 3-7 JTDI/Assoc/DIO5 28 D5 0,1, 3-5 nRTS/DIO6/SClk2 29 D6 0,1, 3-5 AD3/DIO3 30 D3 0,2-5 AD2/DIO2 31 D2 0,2-5 PTI_En/AD1/DIO1 32 D1 0,2-5 AD0/DIO0/Comm 33 D0 0-5  IO Configuration
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 107  To enable an analog or digital IO function on one or more XBee module pin(s), the appropriate configuration command must be issued with the correct parameter. After issuing the configuration command, changes must be applied on the module for the IO settings to take effect. Pin Command Parameter Description 0 disabled 1 Peripheral control 2 Analog 3 Data in monitored 4 Data out default low 5 Data out default High 6 RS485 enable low/packet trace interface 7 RS485 enable high >7 Unsupported  Pull-up resistors can be set for each digital input line using the PR command. The PR value updates the state of all pull-up resistors. IO Sampling The XBee ZB modules have the ability to monitor and sample the analog and digital IO lines. IO samples can be read locally or transmitted to a remote device to provide indication of the current IO line states. (Only API firmware devices can send remote IO sample data out their UART or SPI ports.) There are three ways to obtain IO samples, either locally or remotely: •Queried Sampling  •Periodic Sampling  •Change Detection Sampling. IO sample data is formatted as shown in the table below Bytes Name Description 1 Sample Sets  Number of sample sets in the packet. (Always set to 1.) 2 Digital Channel mask  Digital IO line on the module.   bit 0 = AD0/DIO0   bit 1 = AD1/DIO1   bit 2 = AD2/DIO2   bit 3 = AD3/DIO3   bit 4 = JTRst/DIO4   bit 5 = JTDI/ASSOC/DIO5   bit 6 = RTS/SCLK2/DIO6   bit 7 = CTS/GPIO7   bit 8 = DTR/Slp_Rq/DIO8   bit 9 = N/A   bit 10 = PWN/RSSI/DIO10   bit 11 = PWM1/DIO11   bit 12 = JTMS/SWDIO/CD/DIO12  bit 13=DOUT/DIO13  bit14=DIN/nconfig/DIO14
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 108   bit15=SPI_MISO/DIO15  bit16=SPI_MOSI/DIO16  bit17=SPI_nSSEL/DIO17  bit18=SPI_SCLK/DIO18 For example, a digital channel mask of 0x002F means DIO0 1, 2, 3, and 5 are enabled as digital IO. 1 Analog Channel Mask  Indicates which lines have analog inputs enabled for sampling. Each bit in the analog channel mask corresponds to one analog input channel.       Variable Sampled Data Set  A sample set consisting of 1 sample for each enabled ADC and/or DIO channel, which has voltage inputs of 1143.75 and 342.1875mV.  If any digital IO lines are enabled, the first two bytes of the data set indicate the state of all enabled digital IO. Only digital channels that are enabled in the Digital Channel Mask bytes have any meaning in the sample set. If no digital IO is enabled on the device, these 2 bytes will be omitted.  Following the digital IO data (if any), each enabled analog channel will return 2 bytes. The data starts with AIN0 and continues sequentially for each enabled analog input channel up to AIN3, and the supply voltage (if enabled) at the end.  The sampled data set will include 2 bytes of digital IO data only if one or more IO lines on the device are configured as digital IO. If no pins are configured as digital IO, these 2 bytes will be omitted. The digital IO data is only relevant if the same bit is enabled in the digital IO mask. Analog samples are returned as 14-bit values. The analog reading is scaled such that 0x0000 represents 0V, and 0x3FF = 1.2V. (The analog inputs on the module cannot read more than 1.2V.) Analog samples are returned in order starting with AIN0 and finishing with AIN3, and the supply voltage. Only enabled analog input channels return data as shown in the figure below. To convert the A/D reading to mV, do the following: AD(mV) = (A/D reading * 1200mV) / 1024 The reading in the sample frame represents voltage inputs of 1143.75 and 342.1875mV for AD0 and AD1 respectively. Queried Sampling The IS command can be sent to a device locally, or to a remote device using the API remote command frame (see chapter 8 for details). When the IS command is sent, the receiving device samples all enabled digital IO and analog input channels and returns an IO sample. If IS is sent locally, the IO sample is sent out the UART or SPI port. If the IS command was received as a remote command, the IO sample is sent over-the-air to the device that sent the IS command.
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 109  If the IS command is issued in AT firmware, the module returns a carriage return-delimited list containing the above-listed fields. The API firmware returns an AT command response packet with the IO data included in the command data portion of the response frame. The following table shows an example of the fields in an IS response. Example Sample AT Response 0x01 [1 sample set] 0x0C0C [Digital Inputs: DIO 2, 3, 10, 11 low] 0x03 [Analog Inputs; A/D 0,1] 0x0408 [Digital input states: DIO 3,10 high, DIO 2,11 low] 0x03D0 [Analog input ADIO 0=0x3D0] 0x0124 [Analog input ADIO 1=0x120]  Periodic IO Sampling Periodic sampling allows an XBee/XBee-PRO module to take an IO sample and transmit it to a remote device at a periodic rate. The periodic sample rate is set by the IR command. If IR is set to 0, periodic sampling is disabled. For all other values of IR, data will be sampled after IR milliseconds have elapsed and transmitted to a remote device. The DH and DL commands determine the destination address of the IO samples. DH and DL can be set to 0 to transmit to the coordinator, or to the 64-bit address of the remote device (SH and SL). Only devices running API firmware can send IO data samples out their UART. Devices running AT firmware will discard received IO data samples. A sleeping end device will transmit periodic IO samples at the IR rate until the ST timer expires and the device can resume sleeping. Change Detection Sampling Modules can be configured to transmit a data sample immediately whenever a monitored digital IO pin changes state. The IC command is a bitmask that can be used to set which digital IO lines should be monitored for a state change. If one or more bits in IC is set, an IO sample will be transmitted as soon as a state change is observed in one of the monitored digital IO lines. Change detection samples are transmitted to the 64-bit address specified by DH and DL. RSSI PWM The XBee module features an RSSI/PWM pin (pin 7) that, if enabled, will adjust the PWM output to indicate the signal strength of the last received packet. The P0 (P-zero) command is used to enable the RSSI pulse width modulation (PWM) output on the pin. If P0 is set to 1, the RSSI/PWM pin will output a pulse width modulated signal where the frequency is adjusted based on the received signal strength of the last packet. Otherwise, for all other P0 settings, the pin can be used for general purpose IO. When a data packet is received, if P0 is set to enable the RSSI/PWM feature, the RSSI PWM output is adjusted based on the RSSI of the last packet. The RSSI/PWM output will be enabled for a time based on the RP command. Each time an RF packet is received, the RSSI/PWM output is adjusted based on the RSSI of the new packet, and the RSSI timer is reset. If the RSSI timer expires, the RSSI/PWM pin is driven low. RP is measured in 100ms units and defaults to a value of 40 (4 seconds). The RSSI PWM runs at 12MHz and has 2400 total counts (200us period). RSSI (in dBm) is converted to PWM counts using the following equation: PWM counts = (41 * RSSI_Unsigned)  5928
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 110  IO Examples Example 1: Configure the following IO settings on the XBee Configure AD1/DIO1 as a digital input with pull-up resistor enabled Configure AD2/DIO2 as an analog input Configure DIO4 as a digital output, driving high. To configure AD1/DIO1 as an input, issue the ATD1 command with a parameter of 3 ("ATD13"). To enable pull-up resistors on the same pin, the PR command should be issued with bit 3 set (e.g. ATPR8, ATPR1FFF, etc.). The ATD2 command should be issued with a parameter of 2 to enable the analog input ("ATD22"). Finally, DIO4 can be set as an output, driving high by issuing the ATD4 command with a parameter value of 5 ("ATD45"). After issuing these commands, changes must be applied before the module IO pins will be updated to the new states. The AC or CN commands can be issued to apply changes (e.g. ATAC). Example 2: Calculate the PWM counts for a packet received with an RSSI of -84dBm. RSSI = -84 = 0xAC = 172 decimal (unsigned)  PWM counts = (41 * 172) - 5928  PWM counts = 1124  With a total of 2400 counts, this yields an ON time of (1124 / 2400) = 46.8% Example 3: Configure the RSSI/PWM pin to operate for 2 seconds after each received RF packet. First, ensure the RSSI/PWM functionality is enabled by reading the P0 (P-zero) command. It should be set to 1 (default). To configure the duration of the RSSI/PWM output, set the RP command. To achieve a 2 second PWM output, set RP to 0x14 (20 decimal or 2 seconds) and apply changes (AC command). After applying changes, all received RF data packets should set the RSSI timer for 2 seconds.
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 111  9. API Operation As an alternative to Transparent Operation, API (Application Programming Interface) Operations are available. API operation requires that communication with the module be done through a structured interface (data is communicated in frames in a defined order). The API specifies how commands, command responses and module status messages are sent and received from the module using a UART or SPI Data Frame. Please note that Digi may add new API frames to future versions of firmware, so please build into your software interface the ability to filter out additional API frames with unknown Frame Types. API Frame Specifications Two API modes are supported and both can be enabled using the AP (API Enable) command. Use the following AP parameter values to configure the module to operate in a particular mode: 1: API Operation   API Operation (AP parameter = 1) When this API mode is enabled (AP = 1), the UART or SPI data frame structure is defined as follows: UART  or SPI Data Frame Structure:  Any data received prior to the start delimiter is silently discarded. If the frame is not received correctly or if the checksum fails, the module will reply with a module status frame indicating the nature of the failure. API Operation-with Escape Characters (AP parameter = 2) When this API mode is enabled (AP = 2), the UART or SPI data frame structure is defined as follows: UART or SPI Data Frame Structure ‐ with escape control characters:  Escape characters. When sending or receiving a UART or SPI data frame, specific data values must be escaped (flagged) so they do not interfere with the data frame sequencing. To escape an interfering data byte, insert 0x7D  Data bytes that need to be escaped:   Frame Delimiter   Escape   XON
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 112   XOFF Example -     0x7E 0x00 0x02 0x23 0x11 0xCB  0x7E 0x00 0x02 0x23 0x7D 0x31 0xCB Note: In the above example, the length of the raw data (excluding the checksum) is 0x0002 and the checksum of the non-escaped data (excluding frame delimiter and length) is calculated as: 0xFF - (0x23 + 0x11) = (0xFF - 0x34) = 0xCB. Length The length field has a two-byte value that specifies the number of bytes that will be contained in the frame data field. It does not include the checksum field. Framed Data Frame data of the UART or SPI data frame forms an API-specific structure as follows: UART or SPI Data Frame & API‐specific Structure:  The cmdID frame (API-identifier) indicates which API messages will be contained in the cmdData frame (Identifier-specific data). Note that multi-byte values are sent big endian. The XBee modules support the following API frames: API Frame Names and Values API Frame Names API ID AT Command 0x08 0x08 AT Command - Queue Parameter Value 0x09 ZigBee Transmit Request 0x10 Explicit Addressing ZigBee Command Frame 0x11 Remote Command Request 0x17 Create Source Route 0x20 AT Command Response 0x88 Modem Status 0x8A ZigBee Transmit Status 0x8B ZigBee Receive Packet (AO=0) 0x90 ZigBee Explicit Rx Indicator (AO=1) 0x91 ZigBee IO Data Sample Rx Indicator 0x92 XBee Sensor Read Indicator (AO=0) 0x94 Node Identification Indicator (AO=0) 0x95 Remote Command Response 0x97 Over-the-Air Firmware Update Status 0xA0 Route Record Indicator 0xA1 Many-to-One Route Request Indicator 0xA3
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 113    Checksum To test data integrity, a checksum is calculated and verified on non-escaped data. To calculate: Not including frame delimiters and length, add all bytes keeping only the lowest 8 bits of the result and subtract the result from 0xFF. To verify: Add all bytes (include checksum, but not the delimiter and length). If the checksum is correct, the sum will equal 0xFF. API Examples Example: Create an API AT command frame to configure an XBee to allow joining (set NJ to 0xFF). The frame should look like:   0x7E 0x00 0x05 0x08 0x01 0x4E 0x4A 0xFF 5F Where 0x0005 = length 0x08 = AT Command API frame type  0x01 = Frame ID (set to non-zero value)  0x4E4A = AT Command ('NJ')  0xFF = value to set command to  0x5F = Checksum The checksum is calculated as [0xFF - (0x08 + 0x01 + 0x4E + 0x4A + 0xFF)] Example: Send a remote command to the coordinator to set AD1/DIO1 as a digital input (D1=3) and apply changes to force the IO update. The API remote command frame should look like: 0x7E 0x00 0x10 0x17 0x01 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0xFF 0xFE 0x02 0x44 0x31 0x03 0x70 Where 0x10 = length (16 bytes excluding checksum)  0x17 = Remote Command API frame type  0x01 = Frame ID  0x0000000000000000 = Coordinator's address (can be replaced with coordinator's actual 64-bit address if known)  0xFFFE = 16- bit Destination Address  0x02 = Apply Changes (Remote Command Options)  0x4431 = AT command ('D1')  0x03 = Command Parameter (the parameter could also be sent as  0x0003 or 0x00000003)  0x70 = Checksum API UART and SPI Exchanges AT Commands
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 114  The following image shows the API frame exchange that takes place at the UART or SPI when sending an AT command request to read or set a module parameter. The response can be disabled by setting the frame ID to 0 in the request.   Transmitting and Receiving RF Data The following image shows the API exchanges that take place at the UART or SPI when sending RF data to another device. The transmit status frame is always sent at the end of a data transmission unless the frame ID is set to 0 in the transmit request. If the packet cannot be delivered to the destination, the transmit status frame will indicate the cause of failure. The received data frame (0x90 or 0x91) is set by the AP command.  Remote AT commands The following image shows the API frame exchanges that take place at the UART or SPI when sending a remote AT command. A remote command response frame is not sent out the UART or SPI if the remote device does not receive the remote command.
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 115    Source Routing The following image shows the API frame exchanges that take place at the UART or SPI when sending a source routed transmission.   Supporting the API Applications that support the API should make provisions to deal with new API frames that may be introduced in future releases. For example, a section of code on a host microprocessor that handles received serial API frames (sent out the module's DOUT pin) might look like this: void XBee_HandleRxAPIFrame(_apiFrameUnion *papiFrame){ switch(papiFrame->api_id){ case RX_RF_DATA_FRAME: //process received RF data frame break; case RX_IO_SAMPLE_FRAME: //process IO sample frame break;
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 116  case NODE_IDENTIFICATION_FRAME: //process node identification frame break; default: //Discard any other API frame types that are not being used break; } } API Frames The following sections illustrate the types of frames encountered while using the API. AT Command Frame Type: 0x08 Used to query or set module parameters on the local device. This API command applies changes after executing the command. (Changes made to module parameters take effect once changes are applied.) The API example below illustrates an API frame when modifying the NJ parameter value of the module  The above example illustrates an AT command when querying an NJ value. AT Command-Queue Parameter Value  This API tyChanges) command is issued. Register queries (reading parameter values) are returned immediately. Example: Send a command to change the baud rate (BD) to 115200 baud, but don't apply changes yet. (Module will continue to operate at the previous baud rate until changes are applied.)
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 117   Note: In this example, the parameter could have been sent as a zero-padded 2-byte or 4-byte value. ZigBee Transmit Request Frame Type: 0x10 A Transmit Request API frame causes the module to send data as an RF packet to the specified destination. The 64-bit destination address should be set to 0x000000000000FFFF for a broadcast transmission (to all devices). The coordinator can be addressed by either setting the 64-bit address to all 0x00s and the 16-bit address to 0xFFFE, OR by setting the 64-bit address to the coordinator's 64-bit address and the 16-bit address to 0x0000. For all other transmissions, setting the 16-bit address to the correct 16-bit address can help improve performance when transmitting to multiple destinations. If a 16-bit address is not known, this field should be set to 0xFFFE (unknown). The Transmit Status frame (0x8B) will indicate the discovered 16-bit address, if successful. The broadcast radius can be set from 0 up to NH. If set to 0, the value of NH specifies the broadcast radius (recommended). This parameter is only used for broadcast transmissions. The maximum number of payload bytes can be read with the NP command. Note: if source routing is used, the RF payload will be reduced by two bytes per intermediate hop in the source route. This example shows if escaping is disabled (AP=1).
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 118   Example: The example above shows how to send a transmission to a module where escaping is disabled (AP=1) with destination address 0x0013A200 40014011, payload "TxData1B". If escaping is enabled (AP=2), the frame should look like: 0x7E 0x00 0x16 0x10 0x01 0x00 0x7D 0x33 0xA2 0x00 0x40 0x0A 0x01 0x27 0xFF 0xFE 0x00 0x00 0x54 0x78 0x44 0x61 0x74 0x61 0x30 0x41 0x7D 0x33
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 119  The checksum is calculated (on all non-escaped bytes) as [0xFF - (sum of all bytes from API frame type through data payload)]. Example: Send a transmission to the coordinator without specifying the coordinator's 64-bit address. The API transmit request frame should look like: 0x7E 0x00 0x16 0x10 0x01 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0xFF 0xFE 0x00 0x00 0x54 0x78 032 0x43 0x6F 0x6F 0x72 0x64 0xFC Where  0x16 = length (22 bytes excluding checksum) 0x10 = ZigBee Transmit Request API frame type  0x01 = Frame ID (set to non-zero value)  0x0000000000000000 = Coordinator's address (can be replaced with coordinator's actual 64-bit address if known 0xFFFE = 16-bit Destination Address  0x00 = Broadcast radius  0x00 = Options 0x547832436F6F7264 = Data payload ("Tx2Coord")  0xFC = Checksum Explicit Addressing ZigBee Command Frame Frame Type: 0x11 Allows ZigBee application layer fields (endpoint and cluster ID) to be specified for a data transmission. Similar to the ZigBee Transmit Request, but also requires ZigBee application layer addressing fields to be specified (endpoints, cluster ID, profile ID). An Explicit Addressing Request API frame causes the module to send data as an RF packet to the specified destination, using the specified source and destination endpoints, cluster ID, and profile ID. The 64-bit destination address should be set to 0x000000000000FFFF for a broadcast transmission (to all devices). The coordinator can be addressed by either setting the 64-bit address to all 0x00s and the 16-bit address to 0xFFFE, OR by setting the 64-bit address to the coordinator's 64-bit address and the 16-bit address to 0x0000. For all other transmissions, setting the 16-bit address to the correct 16-bit address can help improve performance when transmitting to multiple destinations. If a 16-bit address is not known, this field should be set to 0xFFFE (unknown). The Transmit Status frame (0x8B) will indicate the discovered 16-bit address, if successful. The broadcast radius can be set from 0 up to NH. If set to 0, the value of NH specifies the broadcast radius (recommended). This parameter is only used for broadcast transmissions. The maximum number of payload bytes can be read with the NP command. Note: if source routing is used, the RF payload will be reduced by two bytes per intermediate hop in the source route.
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 120   Example: Send a data transmission to the coordinator (64-bit address of 0x00s) using a source endpoint of 0xA0, destination endpoint 0xA1, cluster ID =0x1554, and profile ID 0xC105. Payload will be "TxData".
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 121  Remote AT Command Request Frame Type: 0x17 Used to query or set module parameters on a remote device. For parameter changes on the remote device to take effect, changes must be applied, either by setting the apply changes options bit, or by sending an AC command to the remote.  Example: Send a remote command to change the broadcast hops register on a remote device to 1 (broadcasts go to 1-hop neighbors only), and apply changes so the new configuration value immediately takes effect. In this example, the 64-bit address of the remote is 0x0013A200 40401122, and the destination 16-bit address is unknown. Create Source Route Frame Type: 0x21
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 122  This frame creates a source route in the module. A source route specifies the complete route a packet should traverse to get from source to destination. Source routing should be used with many-to-one routing for best results. Note: Both the 64-bit and 16-bit destination addresses are required when creating a source route. These are obtained when a Route Record Indicator (0xA1) frame is received.  Example: Intermediate hop addresses must be ordered starting with the neighbor of the destination, and working closer to the source. For example, suppose a route is found between A and E as shown below. A ' B ' C ' D ' E  If device E has the 64-bit and 16-bit addresses of 0x0013A200 40401122 and 0x3344, and if devices B, C, and D have the following 16-bit addresses:  B = 0xAABB  C = 0xCCDD  D = 0xEEFF  The example above shows how to send the Create Source Route frame to establish a source route between A and E.
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 123  AT Command Response Frame Type: 0x88  In response to an AT Command message, the module will send an AT Command Response message. Some commands will send back multiple frames (for example, the ND (Node Discover) command).  Example: Suppose the BD parameter is changed on the local device with a frame ID of 0x01. If successful (parameter was valid), the above response would be received. Modem Status Frame Type: (0x8A)  RF module status messages are sent from the module in response to specific conditions.  Example: The following API frame is returned when an API coordinator forms a network.  Note: New modem status codes may be added in future firmware releases.
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 124  ZigBee Transmit Status Frame Type: 0x8B When a TX Request is completed, the module sends a TX Status message. This message will indicate if the packet was transmitted successfully or if there was a failure.  Example: Suppose a unicast data transmission was sent to a destination device with a 16-bit address of 0x7D84. (The transmission could have been sent with the 16-bit address set to 0x7D84 or 0xFFFE.)
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 125  ZigBee Receive Packet Frame Type: (0x90)  When the module receives an RF packet, it is sent out the UART or SPI using this message type.  Example: Suppose a device with a 64-bit address of 0x0013A200 40522BAA, and 16-bit address 0x7D84 sends a unicast data transmission to a remote device with payload "RxData". If AO=0 on the receiving device, it would send the above example frame out its UART or SPI.
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 126  ZigBee Explicit RX Indicator Frame Type:0x91  When the modem receives a ZigBee RF packet it is sent out the UART or SPI using this message type (when AO=1).  Example: Suppose a device with a 64-bit address of 0x0013A200 40522BAA, and 16-bit address 0x7D84 sends a broadcast data transmission to a remote device with payload "RxData". Suppose the transmission was sent with source and destination endpoints of 0xE0, cluster ID=0x2211, and profile ID=0xC105. If AO=1 on the receiving device, it would send the above frame out its UART or SPI.
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 127  ZigBee IO Data Sample RX Indicator Frame Type: 0x92  When the module receives an IO sample frame from a remote device, it sends the sample out the UART or SPI using this frame type (when AO=0). Only modules running API firmware will send IO samples out the UART or SPI.
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 128  Example: Suppose an IO sample is received with analog and digital IO, from a remote with a 64- bit address of 0x0013A200 40522BAA and a 16-bit address of 0x7D84. If pin AD1/DIO1 is enabled as an analog input, AD2/DIO2 and DIO4 are enabled as a digital inputs (currently high), and AD3/ DIO3 is enabled as a digital output (low) the IO sample is shown in the API example in the table above. XBee Sensor Read Indicator Frame Type: 0x94  When the module receives a sensor sample (from a Digi 1-wire sensor adapter), it is sent out the UART or SPI using this message type (when AO=0).  Example: Suppose a 1-wire sensor sample is received from a device with a 64-bit address of 0x0013A200 40522BAA and a 16-bit address of 0xDD6C. If the sensor sample was taken from a 1-wire humidity sensor, the API frame could look like this (if AO=0): For convenience, let's label the A/D and temperature readings as AD0, AD1, AD2, AD3, and T. Using the data in this example:
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 129  AD0 = 0x0002  AD1 = 0x00CE  AD2 = 0x00EA AD3 = 0x0052 T = 0x016A To convert these to temperature and humidity values, the following equations should be used. Temperature (°C) = (T / 16), for T < 2048 = - (T & 0x7FF) / 16, for T >= 2048 Vsupply = (AD2 * 5.1) / 255  Voutput = (AD3 * 5.1) / 255  Relative Humidity = ((Voutput / Vsupply) - 0.16) / (0.0062)  True Humidity = Relative Humidity / (1.0546 - (0.00216 * Temperature (°C)))  Looking at the sample data, we have:  Vsupply = (234 * 5.1 / 255) = 4.68  Voutput = (82 * 5.1 / 255) = 1.64  Temperature = (362 / 16) = 22.625°C  Relative H = (161.2903 * ((1.64/4.68) - 0.16)) = 161.2903 * (0.19043) = 30.71%  True H = (30.71 / (1.0546 - (0.00216 * 22.625))) = (30.71 / 1.00573) = 30.54%
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 130  Node Identification Indicator Frame Type: 0x95  This frame is received when a module transmits a node identification message to identify itself (when AO=0). The data portion of this frame is similar to a network discovery response frame (see ND command).  Example: If the commissioning push button is pressed on a remote router device with 64-bit address 0x0013A200 40522BAA, 16-bit address 0x7D84, and default NI string, the following node identification indicator would be received.
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 131  Remote Command Response Frame Type: 0x97  If a module receives a remote command response RF data frame in response to a Remote AT Command Request, the module will send a Remote AT Command Response message out the UART or SPI. Some commands may send back multiple frames--for example, Node Discover (ND) command.  Example: If a remote command is sent to a remote device with 64-bit address 0x0013A200 40522BAA and 16-bit address 0x7D84 to query the SL command, and if the frame ID=0x55, the response is shown in the example API frame in the table above.
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 132  Over-the-Air Firmware Update Status Frame Type: 0xA0  The Over-the-Air Firmware Update Status frame provides a status indication of a firmware update transmission attempt. If a query command (0x01 0x51) is sent to a target with a 64-bit address of 0x0013A200 40522BAA through an updater with 64-bit address 0x0013A200403E0750 and 16-bit address 0x0000, the following is the expected response.  If a query request returns a 0x15 (NACK) status, the target is likely waiting for a firmware update image. If no messages are sent to it for about 75 seconds, the target will timeout and accept new query messages. If a query returns a 0x51 (QUERY) status, then the target's bootloader is not active and will not respond to query messages.
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 133  Route Record Indicator Frame Type: 0xA1  The route record indicator is received whenever a device sends a ZigBee route record command. This is used with many-to-one routing to create source routes for devices in a network.  Example: Suppose device E sends a route record that traverses multiple hops en route to data collector device A as shown below. A B C D E  If device E has the 64-bit and 16-bit addresses of 0x0013A200 40401122 and 0x3344, and if devices B, C, and D have the following 16-bit addresses:  B = 0xAABB  C = 0xCCDD  D = 0xEEFF  The data collector will send the above API frame out its UART or SPI.
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 134  Many-to-One Route Request Indicator Frame Type: 0xA3  The many-to-one route request indicator frame is sent out the UART or SPI whenever a many-to-one route request is received  Example: Suppose a device with a 64-bit address of 0x0013A200 40401122 and 16-bit address of 0x0000 sends a many-to-one route request. All remote routers with API firmware that receive the many-to-one broadcast would send the above example API frame out their UART or SPI.
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 135  Sending ZigBee device objects (ZDO) Commands with the API ZigBee Device Objects (ZDOs) are defined in the ZigBee Specification as part of the ZigBee Device Profile. These objects provide functionality to manage and map out the ZigBee network and to discover services on ZigBee devices. ZDOs are typically required when developing a ZigBee product that will interoperate in a public profile such as home automation or smart energy, or when communicating with ZigBee devices from other vendors. The ZDO can also be used to perform several management functions such as frequency agility (energy detect and channel changes - Mgmt Network Update Request), discovering routes (Mgmt Routing Request) and neighbors (Mgmt LQI Request), and managing device connectivity (Mgmt Leave and Permit Join Request). The following table shows some of the more prominent ZDOs with their respective cluster identifier. Each ZDO command has a defined payload. See the "ZigBee Device Profile" section of the ZigBee Specification for details. ZDO Command Cluster ID Network Address Request  0x0000 IEEE Address Request  0x0001 Node Descriptor Request  0x0002 Simple Descriptor Request  0x0004 Active Endpoints Request  0x0005 Match Descriptor Request  0x0006 Mgmt LQI Request 0x0031 Mgmt Routing Request  0x0032 Mgmt Leave Request  0x0034 Mgmt Permit Joining Request  0x0036 Mgmt Network Update Request  0x0038  The Explicit Transmit API frame (0x11) is used to send ZigBee Device Objects commands to devices in the network. Sending ZDO commands with the Explicit Transmit API frame requires some formatting of the data payload field. When sending a ZDO command with the API, all multiple byte values in the ZDO command (API payload) (e.g. u16, u32, 64-bit addresses) must be sent in little endian byte order for the command to be executed correctly on a remote device. For an API XBee to receive ZDO responses, the AO command must be set to 1 to enable the explicit receive API frame. The following table shows how the Explicit API frame can be used to send an "Active Endpoints" request to discover the active endpoints on a device with a 16-bit address of 0x1234.
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 136
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 137  Sending ZigBee Cluster Library (ZCL) Commands with the API The ZigBee Cluster Library defines a set of attributes and commands (clusters) that can be supported in multiple ZigBee profiles. The ZCL commands are typically required when developing a ZigBee product that will interoperate in a public profile such as home automation or smart energy, or when communicating with ZigBee devices from other vendors. Applications that are not designed for a public profile or for interoperability applications can skip this section. The following table shows some prominent clusters with their respective attributes and commands. Cluster(Cluster ID) Attributes (Attribute ID) Cluster ID Basic (0x0000) Application Version (0x0001)  Hardware Version (0x0003)  Model Identifier (0x0005) -Reset to defaults (0x00) Identify (0x0003) Identify Time (0x0000) Identify (0x00) Identify Query (0x01) Time (0x000A) Time (0x0000)  Time Status (0x0001)  Time Zone (0x0002)  Thermostat (0x0201) Local Temperature (0x0000)  Occupancy (0x0002) -Setpoint raise / lower (0x00)  The ZCL defines a number of profile-wide commands that can be supported on any profile, also known as general commands. These commands include the following. Command (Command ID) Description Read Attributes (0x00) Used to read one or more attributes on a remote device. Read Attributes Response (0x01) Generated in response to a read attributes command. Write Attributes (0x02) Used to change one or more attributes on a remote device. Write Attributes Response (0x04) Sent in response to a write attributes command. Configure Reporting (0x06) Used to configure a device to automatically report on the values of one or more of its attributes. Report Attributes (0x0A) Used to report attributes when report conditions have been satisfied. Discover Attributes (0x0C) Used to discover the attribute identifiers on a remote device. Discover Attributes Response (0x0D) Sent in response to a discover attributes command.  The Explicit Transmit API frame (0x11) is used to send ZCL commands to devices in the network. Sending ZCL commands with the Explicit Transmit API frame requires some formatting of the data payload field. When sending a ZCL command with the API, all multiple byte values in the ZCL command (API Payload) (e.g. u16, u32, 64-bit addresses) must be sent in little endian byte order for the command to be executed correctly on a remote device.
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 138  Note: When sending ZCL commands, the AO command should be set to 1 to enable the explicit receive API frame. This will provide indication of the source 64- and 16-bit addresses, cluster ID, profile ID, and endpoint information for each received packet. This information is required to properly decode received data. The following table shows how the Explicit API frame can be used to read the hardware version attribute from a device with a 64-bit address of 0x0013A200 40401234 (unknown 16-bit address). This example uses arbitrary source and destination endpoints. Recall the hardware version attribute (attribute ID 0x0003) is part of the basic cluster (cluster ID 0x0000). The Read Attribute general command ID is 0x00.
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 139   In the above example, the Frame Control field (offset 23) was constructed as follows:
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 140  Name Bits Example Value Description Frame Type  0-1 00 - Command acts across the entire profile  Manufacturer Specific  2  0 - The manufacturer code field is omitted from the ZCL Frame Header.  Direction 3  0 - The command is being sent from the client side to the server side.  Disable Default Response 4  0 - Default response not disabled  Reserved 5-7  Set to 0.   See the ZigBee Cluster Library specification for details. Sending Public Profile Commands with the API Commands in public profiles such as Smart Energy and Home Automation can be sent with the XBee API using the Explicit Transmit API frame (0x11). Sending public profile commands with the Explicit Transmit API frame requires some formatting of the data payload field. Most of the public profile commands fit into the ZigBee Cluster Library (ZCL) architecture as described in the previous section. The following table shows how the Explicit API frame can be used to send a demand response and load control message (cluster ID 0x701) in the smart energy profile (profile ID 0x0109) in the revision 14 Smart Energy specification. The message will be a "Load Control Event" (command ID 0x00) and will be sent to a device with 64- bit address of 0x0013A200 40401234 with a 16-bit address of 0x5678. The event will start a load control event for water heaters and smart appliances, for a duration of 1 minute, starting immediately. Note: When sending public profile commands, the AO command should be set to 1 to enable the explicit receive API frame. This will provide indication of the source 64- and 16-bit addresses, cluster ID, profile ID, and endpoint information for each received packet. This information is required to properly decode received data.
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 141
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 142   In the above example, the Frame Control field (offset 23) was constructed as follows: Name Bits Example Value Description Frame Type  0-1 00 - Command is specific to a cluster  Manufacturer Specific  2  0 - The manufacturer code field is omitted from the ZCL Frame Header.  Direction 3  0 - The command is being sent from the server side to the client side.  Disable Default Response 4  0 - Default response not disabled  Reserved 5-7  Set to 0.
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 143  10. XBee Command Reference Tables Addressing Addressing Commands AT Command Name and Description Node Type Parameter Range Default DH Destination Address High.Set/Get the upper 32 bits of the 64-bit destination address. When combined with DL, it defines the 64-bit destination address for data transmission. Special definitions for DH and DL include 0x000000000000FFFF (broadcast) and 0x0000000000000000 (coordinator).  CRE 0 - 0xFFFFFFFF 0 DL  Destination Address Low. Set/Get the lower 32 bits of the 64-bit destination address. When combined with DH, it defines the 64-bit destination address for data transmissions. Special definitions for DH and DL include 0x000000000000FFFF (broadcast) and 0x0000000000000000 (coordinator). CRE 0 - 0xFFFFFFFF 0xFFFF(Coordinator) 0 (Router/End Device) MY  16-bit Network Address. Read the 16-bit network address of the module. A value of 0xFFFE means the module has not joined a ZigBee network CRE 0 - 0xFFFE [read-only] 0xFFFE MP 16-bit Parent Network Address. Read the 16-bit network address of the module's parent. A value of 0xFFFE means the module does not have a parent.  E 0 -   [read-only] 0xFFFE NC  Number of Remaining Children. Read the number of end device children that can join the device. If NC returns 0, then the device cannot allow any more end device children to join. CR 0 - MAX_CHILDREN (maximum varies) read-only SH  Serial Number High. Read the high 32 bits of the module's unique 64-bit address. CRE 0 - [read-only] factory-set SL Serial Number Low. Read the low 32 bits of the module's unique 64-bit address. CRE 0 - [read-only] factory-set NI Node Identifier. Stores a string identifier. The register only accepts printable ASCII data. In AT Command Mode, a string cannot start with a space. A carriage return ends the command. Command will automatically end when maximum bytes for the string have been entered. This string is returned as part of the ND (Node Discover) command. This identifier is also used with the DN (Destination Node) command. In AT command mode, an ASCII comma (0x2C) cannot be used in the NI string CRE 20-ASCII string ASCII space character (0x20) SE  Source Endpoint. Set/read the ZigBee application layer source endpoint value. This value will be used as the source endpoint for all data transmissions. SE is only supported in AT firmware.  The default value 0xE8 (Data endpoint) is the Digi data endpoint CRE 0 - 0xFF 0xE8 DE  Destination Endpoint. Set/read Zigbee application layer destination ID value. This value will be used as the destination endpoint all data transmissions. DE is only supported in AT firmware.  The default value (0xE8) is the Digi data endpoint. CRE 0 - 0xFF 0xE8 CI  Cluster Identifier. Set/read Zigbee application layer cluster ID value. This value will be used as the cluster ID for all data transmissions. CI is only supported in AT firmware. The default value0x11 (Transparent data cluster ID). CRE 0 - 0xFFFF 0x11 NP  Maximum RF Payload Bytes. This value returns the maximum number of RF payload bytes that can be sent in a unicast transmission. If APS encryption is used (API transmit option bit enabled), the maximum payload size is reduced by 9 bytes. If source routing is used (AR < 0xFF), the maximum payload size is reduced further. Note: NP returns a hexadecimal value. (e.g. if NP returns 0x54, this is equivalent to 84 bytes) CRE 0 - 0xFFFF [read-only] DO  Device Type Identifier. Stores a device type value. This value can be used to differentiate different XBee-based devices. Digi reserves the range 0 - 0xFFFFFF. For example, Digi currently uses the following DD values to identify various ZigBee products: 0x30001 - ConnectPort X8 Gateway 0x30002 - ConnectPort X4 Gateway 0x30003 - ConnectPort X2 Gateway 0x30005 - RS-232 Adapter 0x30006 - RS-485 Adapter 0x30007 - XBee Sensor Adapter 0x30008 - Wall Router 0x3000A - Digital I/O Adapter 0x3000B - Analog I/O Adapter 0x3000C - XStick 0x3000F - Smart Plug 0x30011 - XBee Large Display 0x30012 - XBee Small Display CRE 0 - 0xFFFFFFFF 0x30000 Node types that support the command: C=Coordinator, R=Router, E=End Device
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 144  Networking Networking Commands AT Command Name and Description Node Type Parameter Range Default CH Operating Channel. Read the channel number used for transmitting and receiving between RF modules. Uses 802.15.4 channel numbers. A value of 0 means the device has not joined a PAN and is not operating on any channel.  CRE XBee 0, 0x0B - 0x1A (Channels 11-26) XBee-PRO 0, 0x0B - 0x18 (Channels 11-26) [read-only] ID Extended PAN ID. Set/read the 64-bit extended PAN ID. If set to 0, the coordinator will select a random extended PAN ID, and the router / end device will join any extended PAN ID. Changes to ID should be written to non-volatile memory using the WR command to preserve the ID setting if a power cycle occurs.  CRE 0 - 0xFFFFFFFFFFFFFFFF 0 OP  Operating Extended PAN ID. Read the 64-bit extended PAN ID. The OP value reflects the operating extended PAN ID that the module is running on. If ID > 0, OP will equal ID. CRE 0x01 - 0xFFFFFFFFFFFFFFFF [read-only] NH  Maximum Unicast Hops. Set / read the maximum hops limit. This limit sets the maximum broadcast hops value (BH) and determines the unicast timeout. The timeout is computed as (50 * NH) + 100 ms. The default unicast timeout of 1.6 seconds (NH=0x1E) is enough time for data and the acknowledgment to traverse about 8 hops. CRE 0 - 0xFF 0x1E BH Broadcast Hops. Set/Read the maximum number of hops for each broadcast data transmission. Setting this to 0 will use the maximum number of hops.  CRE 0 - 0x1E 0 OI  Operating 16-bit PAN ID. Read the 16-bit PAN ID. The OI value reflects the actual 16- bit PAN ID the module is running on. CRE 0 - 0xFFFF [read-only] NT  Node Discovery Timeout. Set/Read the node discovery timeout. When the network discovery (ND) command is issued, the NT value is included in the transmission to provide all remote devices with a response timeout. Remote devices wait a random time, less than NT, before sending their response. CRE 0x20 - 0xFF [x 100 msec] 0x3 C (60d) NO  Network Discovery options. Set/Read the options value for the network discovery command. The options bitfield value can change the behavior of the ND (network discovery) command and/or change what optional values are returned in any received ND responses or API node identification frames. Options include: 0x01 = Append DD value (to ND responses or API node identification frames) 002 = Local device sends ND response frame when ND is issued. CRE 0 - 0x03 [bitfield] 0 SC  Scan Channels. Set/Read the list of channels to scan. Coordinator - Bit field list of channels to choose from prior to starting network. Router/End Device - Bit field list of channels that will be scanned to find a Coordinator/ Router to join. Changes to SC should be written using WR command to preserve the SC setting if a power cycle occurs.  Bit (Channel): 0 (0x0B)   4 (0x0F)   8 (0x13)     12 (0x17)                           1 (0x0C)   5 (0x10)   9 (0x14)     13 (0x18)                           2 (0x0D)   6 (0x11)   10 (0x15)  14 (0x19)                           3 (0x0E)   7 (0x12)   11 (0x16)   15 (0x1A) CRE XBee 1 - 0xFFFF [bitfield] XBee-PRO 1 - 0xEFFF [bitfield]  1FFE SD  Scan Duration. Set/Read the scan duration exponent. Changes to SD should be Coordinator - Duration of the Active and Energy Scans (on each channel) that are used to determine an acceptable channel and Pan ID for Router / End Device - Duration of Active Scan (on each channel) used to locate an available Coordinator / Router to join during Association. Scan Time is measured as:(# Channels to Scan) * (2 ^ SD) * 15.36ms - The number of channels to scan is determined by the SC parameter. The XBee can scan up to 16 channels (SC = 0xFFFF).  Sample Scan Duration times (13 channel scan):  If SD = 0, time = 0.200 sec   SD = 2, time = 0.799 sec SD = 4, time = 3.190 sec  SD = 6, time = 12.780 sec  Note: SD influences the time the MAC listens for beacons or runs an energy scan on a given channel. The SD time is not a good estimate of the router/end device joining time requirements. ZigBee joining adds additional overhead including beacon processing on each channel, sending a join request, etc. that extend the actual joining time. CRE 0 - 7 [exponent] 3
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 145  Networking Commands AT Command Name and Description Node Type Parameter Range Default ZS ZigBee Stack Profile. Set / read the ZigBee stack profile value. This must be set the same on all devices that should join the same network. CRE 0-2 0 NJ Node Join Time. Set/Read the time that a Coordinator/Router allows nodes to join. This value can be changed at run time without requiring a Coordinator or Router to restart. The time starts once the Coordinator or Router has started. The timer is reset on power-cycle or when NJ changes. CR 0 - 0xFF  [x 1 sec] 0XFF (always allows joining) JV  Channel Verification. Set/Read the channel verification parameter. If JV=1, a router will verify the coordinator is on its operating channel when joining or coming up from a power cycle. If a coordinator is not detected, the router will leave its current channel and attempt to join a new PAN. If JV=0, the router will continue operating on its current channel even if a coordinator is not detected. R 0 - Channel verification disabled 1 - Channel verification enabled 0 NW  Network Watchdog Timeout. Set/read the network watchdog timeout value. If NW is set > 0, the router will monitor communication from the coordinator (or data collector) and leave the network if it cannot communicate with the coordinator for 3 NW periods. The timer is reset each time data is received from or sent to a coordinator, or if a many-to-one broadcast is received. R 0 - 0x64FF  [x 1 minute]  (up to over 17 days) 0 (disabled) JN Join Notification. Set / read the join notification setting. If enabled, the module will transmit a broadcast node identification packet on power up and when joining. This action blinks the Associate LED rapidly on all devices that receive the transmission, and sends an API frame out the UART of API devices. This feature should be disabled for large networks to prevent excessive broadcasts. RE 0-1 0 AR  Aggregate Routing Notification. Set/read time between consecutive aggregate route broadcast messages. If used, AR should be set on only one device to enable many-to-one routing to the device. Setting AR to 0 only sends one broadcast CR 0 - 0xFF 0 - 0xFF
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 146  Security Security Commands AT Command Name and Description Node Type Parameter Range Default EE Encryption Enable. Set/Read the encryption enable setting. CRE 0 - Encryption disabled  1 - Encryption enabled 0 EO Encryption Options. Configure options for encryption. Unused option bits should be set to 0. Options include:  0x01 - Send the security key unsecured over-the-air during joins  0x02 - Use trust center (coordinator only) CRE 0 - 0xFF  NK  Network Encryption Key. Set the 128-bit AES network encryption key. This command is write-only; NK cannot be read. If set to 0 (default), the module will select a random network key. C 128-bit value 0 KY  Link Key. Set the 128-bit AES link key. This command is write only; KY cannot be read. Setting KY to 0 will cause the coordinator to transmit the network key in the clear to joining devices, and will cause joining devices to acquire the network key in the clear when joining. CRE 128-bit value 0
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 147  RF Interfacing RF Interfacing Commands AT Command Name and Description Node Type Parameter Range Default PL Power Level. Select/Read the power level at which the RF module transmits conducted power. For XBee-PRO (S2B) Power Level 4 is calibrated and the other power levels are approximate. CRE XBee (boost mode) Channel 11-25  0 = 0 dBm  1 = 2 dBm  2 = 4 dBm  3 = 6 dBm   4 = 8 dBm  XBee (boost mode) Channel 26  0 = 0 dBm  1 = 2 dBm  2 = 3 dBm  3 = 3dBm   4 = 3 dBm  XBee  (Normal mode) Channel 11-25  0 = -3 dBm  1 = -1 dBm  2 = 1 dBm  3 = 3 dBm   4 = 5 dBm  XBee  (Normal mode) Channel 26  0 = -3 dBm  1 = -1 dBm  2 = 1 dBm  3 = 3 dBm   4 = 3 dBm  XBee-PRO Channel 11-25 0 = 10 dBm  1 = 12 dBm  2 = 14 dBm  3 = 16 dBm   4 = 18 dBm  4 PM Power Mode. Set/read the power mode of the device. Enabling boost mode will improve the receive sensitivity by 1dB and increase the transmit power by 2dB Note: Enabling boost mode on the XBee-PRO (S2) will not affect the output power. Boost mode imposes a slight increase in current draw. See section 1.2 for details. CRE 0- -Boost mode disabled,  1= Boost mode enabled 1 DB  Received Signal Strength. This command reports the received signal strength of the last received RF data packet. The DB command only indicates the signal strength of the last hop. It does not provide an accurate quality measurement for a multihop link. DB can be set to 0 to clear it. The DB command value is measured in -dBm. For example if DB returns 0x50, then the RSSI of the last packet received was -80dBm. As of 2x6x firmware, the DB command value is also updated when an APS acknowledgment is received. CRE 0 - 0xFF Observed range for XBee-PRO: 0x1A - 0x58 For XBee: 0x 1A - 0x5C  PP  Peak Power. Read the dBm output when maximum power is selected (PL4). CRE 0x0-0x12 [read only]
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 148  Serial Interfacing Serial Interfacing Commands AT Command Name and Description Node Type Parameter Range Default AP API Enable. Enable API Mode. The AP command is only supported when using API firmware: 21xx (API coordinator), 23xx (API router), 29xx (API end device). CRE 1 - 2  1 = API-enabled  2 = API-enabled (w/escaped control characters) 1 AO API Options. Configure options for API. Current options select the type of receive API frame to send out the Uart for received RF data packets. CRE 0 - Default receive API indicators enabled  1 - Explicit Rx data indicator API frame enabled (0x91)  3 - enable ZDO passthrough of ZDO requests to the UART which are not supported by the stack, as well as Simple_Desc_req, Active_EP_req, and Match_Desc_req. 0 BD Interface Data Rate. Set/Read the serial interface data rate for communication between the module serial port and host. Any value above 0x07 will be interpreted as an actual baud rate. When a value above 0x07 is sent, the closest interface data rate represented by the number is stored in the BD register. CRE 0 - 7  (standard baud rates)  0 = 1200 bps  1 = 2400  2 = 4800  3 = 9600  4 = 19200  5 = 38400  6 = 57600  7 = 115200  0x80 - 0xE1000 (non-standard rates up to 921kbps) 3 NB Serial Parity. Set/Read the serial parity setting on the module. CRE 0 = No parity  1 = Even parity  2 = Odd parity  3 = Mark parity 0 SB Stop Bits. Set/read the number of stop bits for the UART. (Two stop bits are not supported if mark parity is enabled.) CRE 0 = 1 stop bit  1 = 2 stop bits 0 RO Packetization Timeout. Set/Read number of character times of inter-character silence required before packetization. Set (RO=0) to transmit characters as they arrive instead of buffering them into one RF packet The RO command is only supported when using AT firmware: 20xx (AT coordinator), 22xx (AT router), 28xx (AT end device). CRE 0 - 0xFF  [x character times] 3 D7 DIO7 Configuration. Select/Read options for the DIO7 line of the RF module. CRE 0 = Disabled 1 = CTS Flow Control  3 = Digital input  4 = Digital output, low  5 = Digital output, high  6 = RS-485 transmit enable (low enable) 7 = RS-485 transmit enable (high enable) 1 D6 DIO6 Configuration. Configure options for the DIO6 line of the RF module. CRE 0 = Disabled  1 = RTS flow control 3 = Digital input  4 = Digital output, low  5 = Digital output, high 0  1. Node types that support the command: C = Coordinator, R = Router, E = End Device
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 149  Serial Interfacing Serial Interfacing Commands AT Command Name and Description Node Type Parameter Range Default IR IO Sample Rate. Set/Read the IO sample rate to enable periodic sampling. For periodic sampling to be enabled, IR must be set to a non-zero value, and at least one module pin must have analog or digital IO functionality enabled (see D0-D8, P0-P2 commands). The sample rate is measured in milliseconds. CRE 0, 0x32:0xFFFF (ms) 0 IC IO Digital Change Detection. Set/Read the digital IO pins to monitor for changes in the IO state. IC works with the individual pin configuration commands (D0-D8, P0-P2). If a pin is enabled as a digital input/output, the IC command can be used to force an immediate IO sample transmission when the DIO state changes. IC is a bitmask that can be used to enable or disable edge detection on individual channels. Unused bits should be set to 0. Bit (IO pin): 0 (DIO0)4 (DIO4)8 (DIO8) 1 (DIO1) 5 (DIO5) 9 (DIO9) 2 (DIO2) 6 (DIO6) 10 (DIO10) 3 (DIO3) 7 (DIO7) 11 (DIO11) CRE 0 - 0xFFFF 0 P0 PWM0 Configuration. Select/Read function for PWM0. CRE 1 = RSSI PWM  3 - Digital input, monitored  4 - Digital output, default low  5 - Digital output, default high 1 P1 DIO11 Configuration. Configure options for the DIO11 line of the RF module. CRE 0 - Unmonitored digital input  3- Digital input, monitored  4- Digital output, default low  5- Digital output, default high 0 P2 DIO12 Configuration. Configure options for the DIO12 line of the RF module. CRE 0 - Unmonitored digital input  3- Digital input, monitored  4- Digital output, default low  5- Digital output, default high 0 P3 DIO13 Configuration. UART Data Out or Set/Read function for DIO13.  CRE 0 - Unmonitored digital input  3- Digital input, monitored  4- Digital output, default low  5- Digital output, default high 4 P4 DIO14 Configuration.  UART Data In CRE 3-Digital Input, monitored (not set-able) 3 P5 DIO15 Configuration.  Set for SPI function CRE 0-Unmonitored digital input 1-SPI MISO 1 P6 DIO16 Configuration.  Set for SPI function CRE 0-Unmonitored digital input 1-SPI MOSI 1 P7 DIO17 Configuration.  Set for SPI function CRE 0-Unmonitored digital input 1-SPI nSSEL 1 P8 DIO18 Configuration.  Set for SPI function CRE 0-Unmonitored digital input 1-SPI SCLK 1 P9 DIO19 Configuration.  Set for SPI function CRE 0-Unmonitored digital input 1-SPI nATTN 1
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 150  Serial Interfacing Commands AT Command Name and Description Node Type Parameter Range Default D0 AD0/DIO0 Configuration. Select/Read function for AD0/DIO0. CRE 0-Disabled 1  Commissioning button enabled  2-Analog input, single ended 3 - Digital input, monitored  4 - Digital output, default low  5 - Digital output, default high 1 D1 AD1/DIO1 Configuration. Select/Read function for AD1/DIO1 CRE 0 - Unmonitored digital input  2-Analog input, single ended 3- Digital input, monitored  4- Digital output, default low  5- Digital output, default high 0 D2 AD2/DIO2 Configuration. Select/Read function for AD2/DIO2 CRE 0 - Unmonitored digital input  2-Analog input, single ended 3- Digital input, monitored  4- Digital output, default low  5- Digital output, default high 0 D3 AD3/DIO3 Configuration. Select/Read function for AD3/DIO3. CRE 0 - Unmonitored digital input  3- Digital input, monitored  4- Digital output, default low  5- Digital output, default high 0 D4 DIO4 Configuration. Select/Read function for DIO4. CRE 0 - Unmonitored digital input  3- Digital input, monitored  4- Digital output, default low  5- Digital output, default high 0 D5 DIO5 Configuration. Configure options for the DIO5 line of the RF module. CRE 0 = Disabled indication LED  3 = Digital input  4 = Digital output, default low  5 = Digital output, default high 1 D6 DIO6 Configuration. Configure options for the DIO5 line of the RF module. CRE 0 = Disabled 1 = RTS indication  3 = Digital input  4 = Digital output, default low  5 = Digital output, 0
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 151  default high) Serial Interfacing Commands AT Command Name and Description Node Type Parameter Range Default D7 DIO7 Configuration. Configure options for the DIO5 line of the RF module. CRE 0 = Disabled 1 = CTS indication  3 = Digital input  4 = Digital output, default low  5 = Digital output, default high) 1 D8 DIO8 Configuration. Configure options for the DIO5 line of the RF module. CRE 0 - Unmonitored digital input  3- Digital input, monitored  4- Digital output, default low  5- Digital output, default high 3,4 LT Assoc LED Blink Time. Set/Read the Associate LED blink time. If the Associate LED functionality is enabled (D5 command), this value determines the on and off blink times for the LED when the module has joined a network. If LT=0, the default blink rate will be used (500ms coordinator, 250ms router/end device). For all other LT values, LT is measured in 10ms. CRE 0, 0x0A - 0xFF (100 - 2550 ms) 0 PR Pull-up Resistor. Set/read the bit field that configures the internal pull-up resistor status for the I/O lines. "1" specifies the pull-up resistor is enabled. "0" specifies no pullup.(30k pull-up resistors)  Bits:*  0 - DIO4 (Pin 11)  1 - AD3 / DIO3 (Pin 17)  2 - AD2 / DIO2 (Pin 18)  3 - AD1 / DIO1 (Pin 19)  4 - AD0 / DIO0 (Pin 20)  5 - RTS / DIO6 (Pin 16)  6 - DTR / Sleep Request / DIO8 (Pin 9)  7 - DIN / Config (Pin 3)  8 - Associate / DIO5 (Pin 15)  9 - On/Sleep / DIO9 (Pin 13)  10 - DIO12 (Pin 4)  11 - PWM0 / RSSI / DIO10 (Pin 6)  12 - PWM1 / DIO11 (Pin 7)  13 - CTS / DIO7 (Pin 12) CRE 0 - 0x3FFF 0 - 0x1FFF RP RSSI PWM Timer. Time the RSSI signal will be output on the PWM after the last RF data reception or APS acknowledgment.. When RP = 0xFF, output will always be on. CRE 0 - 0xFF [x 100 ms] 0x28 (40d) %V Supply Voltage. Reads the voltage on the Vcc pin. Scale by 1200/1024 to convert to mV units. For examplee, a %V reading of 0x900 (2304 decimal) represents 2700mV or 2.7OV. CRE -0x-0xFFFF  [read only] - V+ Voltage Supply Monitoring. The voltage supply threshold is set with the V+ command. If the measured supply voltage falls below or equal to this threshold, the supply voltage will be included in the IO sample set. V+ is set to 0 by default (do not include the supply voltage). Scale mV units by 1024/1200 to convert to internal units. For example, for a 2700mV threshold enter 0x900.  Given the operating Vcc ranges for different platforms, and scaling by 1024/1200, the useful parameter ranges are:  XBee 2100-3600 mV 0,0x0700-0x0c00  XBee-PRO 2700-3400 mV, 0,0x0a00-0x0b55  CRE 0-0xFFFF 0 TP Reads the module temperature in Degrees Celsius. Accuracy +/- 7 degrees. 1° C = 0x0001 and -1° C = 0xFFFF. Command is only available in PRO S2C. CRE 0x0-0xFFFF -
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 152  Diagnostics Interfacing Diagnostics Commands AT Command Name and Description Node Type Parameter Range Default VR Firmware Version. Read firmware version of the module.  The firmware version returns 4 hexadecimal values (2 bytes) "ABCD". Digits ABC are the main release number and D is the revision number from the main release. "B" is a variant designator.  XBee and XBee-PRO ZB modules return:  firmware versions.  XBee and XBee-PRO ZNet modules return:  firmware versions. ZNet firmware is not compatible with ZB firmware. CRE 0 - 0xFFFF [read-only] Factory-set HV Hardware Version. Read the hardware version of the module.  This command can be used to distinguish among different hardware platforms. The upper byte returns a value that is unique to each module type. The lower byte indicates the hardware revision. XBee ZB and XBee ZNet modules return the following (hexadecimal) values:  0x19xx - XBee module  0x1Axx - XBee-PRO module CRE 0 - 0xFFFF [read-only] Factory-set AL Association Indication. Read information regarding last node join request:  0x00 - Successfully formed or joined a network. (Coordinators form a network, routers and end devices join a network.)  0x21 - Scan found no PANs  0x22 - Scan found no valid PANs based on current SC and ID settings  0x23 - Valid Coordinator or Routers found, but they are not allowing joining (NJ expired)  0x27 - Node Joining attempt failed (typically due to incompatible security settings) 0x2A -  0x2B - Checking for an existing coordinator  0xAB - Attempted to join a device that did not respond.  0xAC - Secure join error - network security key received unsecured  0xAD - Secure join error - network security key not received  0xAF - Secure join error - joining device does not have the right preconfigured link key  0xFF - Scanning for a ZigBee network (routers and end devices)  Note: New non-zero AI values may be added in later firmware versions. Applications should read AI until it returns 0x00, indicating a successful startup (coordinator) or join (routers and end devices) CRE 0 -  -only] - TP Reads the module temperature in Degrees Celsius. Accuracy +/- 7 degrees. 1° C = 0x0001 and -1° C = 0xFFFF. Command is only available in PRO S2B. CRE 0x0-0xFFFF -  1. Node types that support the command: C = Coordinator, R = Router, E = End Device
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 153  AT Command Options AT Command Options Commands AT Command Name and Description Node Type Parameter Range Default CT Command Mode Timeout. Set/Read the period of inactivity (no valid commands received) after which the RF module automatically exits AT Command Mode and returns to Idle Mode. CRE 2 - 0x028F [x 100 ms] 0x64 (100d) CN Exit Command Mode. Explicitly exit the module from AT Command Mode. CRE - - GT Guard Times. Set required period of silence before and after the Command Sequence Characters of the AT Command Mode Sequence (GT + CC + GT). The period of silence is used to prevent inadvertent entrance into AT Command Mode. CRE 1 - (max of 3.3 decimal sec) 0x3E8  (1000d) CC between Guard Times of the AT Command Mode Sequence (GT + CC + GT). The AT Command Mode Sequence enters the RF module into AT Command Mode. The CC command is only supported when using AT firmware: 20xx (AT coordinator), 22xx (AT router), 28xx (AT end device). CRE 0 - 0xFF 0x2B    1. Node types that support the command: C = Coordinator, R = Router, E = End Device  Sleep Commands Sleep Commands AT Command Name and Description Node Type Parameter Range Default SM Sleep Mode Sets the sleep mode on the RF module. An XBee loaded with router firmware can be configured as either a router (SM set to 0) or an end device (SM > 0). Changing a device from a router to an end device (or vice versa) forces the device to leave the network and attempt to join as the new device type when changes are applied RE 0-Sleep disabled (router)  1-Pin sleep enabled 4-Cyclic sleep enabled  5 - Cyclic sleep, pin wake 0 - Router 4 - End Device SN Number of Sleep Periods. Sets the number of sleep periods to not assert the On/Sleep pin on wakeup if no RF data is waiting for the end device. This command allows a host application to sleep for an extended time if no RF data is present CRE 1 - 0xFFFF 1 SP Sleep Period. This value determines how long the end device will sleep at a time, up to 28 seconds. (The sleep time can effectively be extended past 28 seconds using the SN command.) On the parent, this value determines how long the parent will buffer a message for the sleeping end device. It should be set at least equal to the longest SP time of any child end device. E 0x20 - 0xAF0 x 10ms (Quarter second resolution) 0x20 SO Command Sleep Options. Configure options for sleep. Unused option bits should be set to 0. Sleep options include:  0x02 - Always wake for ST time  0x04 - Sleep entire SN *  SP time Sleep options should not be used for most applications. See chapter 6 for more information. E 0 - 0xFF 0 WH Wake Host. Set/Read the wake host timer value. If the wake host timer is set to a non-zero value, this timer specifies a time (in millisecond units) that the device should allow after waking from sleep before sending data out the UART or transmitting an IO sample. If serial characters are received, the WH timer is stopped immediately. E 0 - 0xFFFF (x 1ms)  SI Sleep Immediately. See Execution Commands table below..    PO Polling Rate. Sets the polling rate for the end device. E 0 - 0x1770 (10msec) 0x00 (100 msec)
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 154  Execution Commands Where most AT commands set or query register values, execution commands cause an action to be executed on the module. Execution commands are executed immediately and do not require changes to be applied.  Execution Commands AT Command Name and Description Node Type Parameter Range Default AC Apply Changes. Applies changes to all command registers causing queued command register values to be applied. For example, changing the serial interface rate with the BD command will not change the UART interface rate until changes are applied with the AC command. The CN command and 0x08 API command frame also apply changes. CRE - - WR Write. Write parameter values to non-volatile memory so that parameter modifications persist through subsequent resets. Note: Once WR is issued, no additional characters should be sent to the module until after the "OK\r" response is received. The WR command should be used sparingly. The EM250 supports a limited number of write cycles.* CRE - - RE Restore Defaults. Restore module parameters to factory defaults. CRE - - FR Software Reset. Reset module. Responds immediately with an OK status, and then performs a software reset about 2 seconds later. CRE - - NR Network Reset. Reset network layer parameters on one or more modules within a . All network configuration and routing information is consequently lost.  If NR = 0: Resets network layer parameters on the node issuing the command.  If NR = 1: Sends broadcast transmission to reset network layer parameters on all nodes in the PAN. CRE 0 -1 - SI Sleep Immediately. Cause a cyclic sleep module to sleep immediately rather than wait for the ST timer to expire. E - - CB Commissioning Pushbutton. This command can be used to simulate commissioning button presses in software. The parameter value should be set to the number of button presses to be simulated. For example, sending the ATCB1 command will execute the action associated with 1 commissioning button press. CRE   ND Node Discover. Discovers and reports all RF modules found. The following information is reported for each module discovered. MY<CR> SH<CR> SL<CR> NI<CR> (Variable length) PARENT_NETWORK ADDRESS (2 Bytes)<CR> DEVICE_TYPE<CR> (1 Byte: 0=Coord, 1=Router, 2=End Device) STATUS<CR> (1 Byte: Reserved) PROFILE_ID<CR> (2 Bytes) MANUFACTURER_ID<CR> (2 Bytes)<CR> After (NT * 100) milliseconds, the command ends by returning a <CR>. ND also accepts a Node Identifier (NI) as a parameter (optional). In this case, only a module that matches the supplied identifier will respond.  If ND is sent through the API, each response is returned as a separate AT_CMD_Response packet. The data consists of the above listed bytes without the carriage return delimiters. The NI string will end in a "0x00" null character. The radius of the ND command is set by the BH command. CRE optional 20-NI or MY value -
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 155  Execution Commands AT Command Name and Description Node Type Parameter Range Default DN Destination Node. Resolves an NI (Node Identifier) string to a physical address (case-sensitive). The following events occur after the destination node is discovered: <AT Firmware>  1. DL & DH are set to the extended (64-bit) address of the module with the matching       NI (Node Identifier) string. 2. OK (or ERROR)\r is returned.   3. Command Mode is exited to allow immediate communication  <API Firmware> 1. The 16-bit network and 64-bit extended addresses are returned in an API   Command Response frame.  If there is no response from a module within (NT * 100) milliseconds or a parameter returned. In the case of an ERROR, Command Mode is not exited. The radius of the DN command is set by the BH command. CRE up to 20-Byte printable ASCII string - IS Force Sample Forces a read of all enabled digital and analog input lines. CRE - - 1S XBee Sensor Sample. Forces a sample to be taken on an XBee Sensor device. This command can only be issued to an XBee sensor device using an API remote command. RE - -  Node types that support the command: C = Coordinator, R = Router, E = End Device
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 156  11. Module Support This chapter provides customization information for the XBee/XBee-PRO ZB modules. In addition to providing an extremely flexible and powerful API, the XBee and XBee-PRO ZB modules are a robust development platform that have passed FCC and ETSI testing. Developers can customize default parameters, or even write or load custom firmware for Ember's EM357 chip. X-CTU Configuration Tool Digi provides a Windows X-CTU configuration tool for configuring module parameters and updating firmware. The XCTU has the capability to do the following:     Contact Digi support for more information about the X-CTU. Customizing XBee ZB Firmware Once module parameters are tested in an application and finalized, Digi can manufacture modules with specific, customer-defined configurations for a nominal fee. These custom configurations can lock in a firmware version or set command values when the modules are manufactured, eliminating the need for customers to adjust module parameters on arrival. Alternatively, Digi can program custom firmware, including Ember's EZSP UART image, into the modules during manufacturing. Contact Digi to create a custom configuration. Design Considerations for Digi Drop-In Networking XBee/XBee-PRO embedded RF modules contain a variety of features that allow for interoperability with Digi's full line of Drop-in Networking products. Interoperability with other "DIN" products can offer these advantages: -connectivity to your network via Cellular, Ethernet or WiFi with a ConnectPort X Gateway.   sy by enabling the Commissioning Pushbutton (pin 20) and AssociateLED (pin 15) to oper-ate with the Network Commissioning Tool software.  -232, USB, Analog & Digital I/O, RS-485, and other industrial devices using XBee Adapters.   review of your product for interoperability with Digi's Drop-in Networking solutions. XBee Bootloader mechanism that uses module pins DIN (pin 3), DTR / SLEEP_RQ (pin 9), and RTS (pin 16). To invoke the bootloader, do the following:
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 157  1. Set DTR / SLEEP_RQ low (TTL 0V) and RTS high.  2. Send a serial break to the DIN pin and power cycle or reset the module.  3. When the module powers up, DTR / SLEEP_RQ and DIN should be low (TTL 0V) and RTS should be high.  4. Terminate the serial break and send a carriage return at 115200bps to the module.  5. If successful, the module will send the Ember bootloader menu out the DOUT pin at 115200bps.  6. Commands can be sent to the bootloader at 115200bps.  Note: Hardware flow control should be disabled when entering and communicating with the EM250 boot-loader. Programming XBee Modules Firmware on the XBee and XBee-PRO ZB modules can be updated through one of two means:    Each method is described below. Serial Firmware Updates Serial firmware updates make use of the XBee custom bootloader which ships in all units. This modified bootloader is based on Ember's standalone bootloader, but with a modified entry mechanism. The modified entry mechanism uses module pins 4, 10, and 30 (DIN, DTR, and RTS respectively). The X-CTU program can update firmware serially on the XBee and XBee-PRO ZB modules. Contact Digi support for details. If an application requires custom firmware to update the XBee firmware serially, the following steps are required. Invoke XBee Bootloader See the "XBee Bootloader" section above for steps to invoke the bootloader  Send Firmware Image  After invoking the bootloader, the Ember bootloader will send the bootloader menu characters out the UART at 115200 bps. The application should do the following to upload a firmware image. 1. Look for the bootloader prompt "BL >" to ensure the bootloader is active  2. Send an ASCII "1" character to initiate a firmware update  3. After sending a "1", the EM250 waits for an XModem CRC upload of an .ebl image over the serial line at 115200 bps. The .ebl file must be sent to the EM250 in order. If no serial transaction is initiated within a 60 second timeout period, the bootloader times out and returns to the menu. If the upload is interrupted with a power cycle or reset event, the EM250 will detect an invalid application image and enter bootloader mode. The entire ebl image should be uploaded again to recover. If an error occurs while uploading, the EM250 bootloader returns an error code from the following table:
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 158  Hex Error Code Description 0x21 The bootloader encountered an error while trying to parse the Start of Header (SOH) character in the XModem frame. 0x22 The bootloader detected an invalid checksum in the XModem frame.  0x23 The bootloader encountered an error while trying to parse the high byte of the CRC in the XModem frame. 0x24 The bootloader encountered an error while trying to parse the low byte of the CRC in the XModem frame.  0x25 The bootloader encountered an error in the sequence number of the current XModem frame.  0x26  The frame that the bootloader was trying to parse was deemed incomplete (some bytes missing or lost). 0x27  The bootloader encountered a duplicate of the previous XModem frame. 0x41  No .ebl header was received when expected. 0x42  Header failed CRC. 0x43  File failed CRC. 0x44  Unknown tag detected in .ebl image. 0x45  Invalid .ebl header signature. 0x46  Trying to flash odd number of bytes. 0x47  Indexed past end of block buffer. 0x48  Attempt to overwrite bootloader flash. 0x49  Attempt to overwrite SIMEE flash. 0x4A  Flash erase failed. 0x4B  Flash write failed. 0x4C  End tag CRC wrong length. 0x4D  Received data before query request/response  Writing Custom Firmware The XBee/XBee-PRO module can be used as a hardware development platform for the EM250. Custom firmware images can be developed around the EmberZNet 2.5.x and 3.x mesh stacks (for the EM250) and uploaded to the XBee. Warning: If programming firmware through the SIF interface, be aware that uploading firmware through the SIF header can potentially erase the XBee bootloader. If this happens, serial firmware updates will not work. Regulatory Compliance XBee modules are FCC and ETSI certified for operation on all 16 channels. The EM357 output power can be configured up to 8dBm with boost mode enabled. XBee-PRO modules are certified for operation on 15 of the 16 band channels (channels 11 - 25). The scan channels mask of XBee-PRO devices must be set in the application to disable the upper two channels (e.g. 0x01FFF800). The XBee-PRO contains power compensation circuitry to adjust the output power near 18dBm. For best results, the EM357 should be configured with an output power level of -4dBm. The end product is responsible to adhere to these requirements.
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 159  Configuring GPIOs  Most of the remaining sections in this chapter describe how to configure GPIO  to function correctly in custom applications that run on the XBee and XBee-PRO modules. In order for the GPIO to be configurable, the application must set the GPIO_CFG register to enable the appropriate GPIO. The following table lists values for configuring the GPIO pins. Other functionality is affected by these settings. See the EM357 datasheet from Ember for a complete listing of functionality. GPIO Mode GPIO_PxCFGH/L Description Analog 0x0 Analog input or output. When in analog mode, the digital input (GPIO_PxIN) always reads 1. Input (floating) 0x4 Digital input without an internal pull up or pull down. Output is disabled. Input (pull-up or pull-down) 0x8 Digital input with an internal pull up or pull down. A set bit in GPIO_PxOUT selects pull up and a cleared bit selects pull down. Output is disabled. Output (push-pull) 0x1 Push-pull output. GPIO_PxOUT controls the output. Output (open-drain) 0x5 Open-drain output. GPIO_PxOUT controls the output. If a pull up is required, it must be external. Alternate Output (push-pull) 0x9 Push-pull output. An onboard peripheral controls the output. Alternate Output (open-drain) 0xD Open-drain output. An onboard peripheral controls the output. If a pull up is required, it must be external.  The GPIO CFG command is used to configure the functionality of the GPIOs.  The GPIOs are configured in 3 ports (A, B and C).  For example, to Configure port A for all input (floating) the following command would be used: GPIOCFG PA 44444444. To configure Port B with GPIO 0,2,4, and 6 for Output (open-drain), and the other GPIOs in port B for output(push-pull) the following would be used: GPIOCFG PB 51515151. For more information on configuring and setting GPIOs consult the EM357 specification. Detecting XBee vs. XBee-PRO For some applications, it may be necessary to determine if the code is running on an XBee or an XBee-PRO device. The GPIO1 pin on the EM357 is used to identify the module type (see table 1-03 in chapter 1). GPIO1 is connected to ground on the XBee module. The following code could be used to determine if a module is an XBee or XBee-PRO: GPIO_DIRCLRL = GPIO(1);// Set GPIO1 as an input  GPIO_PUL |= GPIO(1);// Enable GPIO1 pull-up resistor  ModuleIsXBeePro = (GPIO_INL & GPIO(1));//ModuleIsXBeePro > 0 if XBee-PRO, =0 if non-PRO.
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 160  12. Agency Certifications United States FCC The XBee RF Module complies with Part 15 of the FCC rules and regulations. Compliance with the labeling requirements, FCC notices and antenna usage guidelines is required. To fulfill FCC Certification, the OEM must comply with the following regulations: 1. The system integrator must ensure that the text on back side of the module is placed on the outside of the final product. 2. XBee RF Module may only be used with antennas that have been tested and approved for use with this module [refer to the antenna tables in this section]. OEM Labeling Requirements WARNING: The Original Equipment Manufacturer (OEM) must ensure that FCC labeling requirements are met. This includes a clearly visible label on the outside of the final product enclosure that displays the contents shown in the figure below.  Required FCC Label for OEM products containing the XBee S2C RF Module Contains FCC ID: MCQ-XBS2C This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.  Required FCC Label for OEM products containing the XBee-PRO S2C RF Module Contains FCC ID: MCQ-XBPS2C  This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.  FCC Notices IMPORTANT: The XBee and XBee PRO RF Module have been certified by the FCC for use with other products without any further certification (as per FCC section 2.1091). Modifications not expressly approved by Digi could void the user's authority to operate the equipment.
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 161  IMPORTANT: OEMs must test final product to comply with unintentional radiators (FCC section 15.107 & 15.109) before declaring compliance of their final product to Part 15 of the FCC Rules. IMPORTANT: The RF module has been certified for remote and base radio applications. If the module will be used for portable applications, the device must undergo SAR testing. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy, and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Re-orient or relocate the receiving antenna, Increase the separation between the equipment and receiver, Connect equipment and receiver to outlets on different circuits, or Consult the dealer or an experienced radio/TV technician for help. FCC-Approved Antennas (2.4 GHz) The XBee and XBee-PRO RF Module can be installed utilizing antennas and cables constructed with non-standard connectors (RPSMA, RPTNC, etc.). The modules are FCC approved for fixed base station and mobile applications for the channels indicated in the tables below. If the antenna is mounted at least 20cm (8 in.) from nearby persons, the application is considered a mobile application. Antennas not listed in the table must be tested to comply with FCC Section 15.203 (Unique Antenna Connectors) and Section 15.247 (Emissions). XBee RF Modules: XBee RF Modules have been tested and approved for use with all the antennas listed in the tables below. Cable loss is required when using gain antennas as shown below. The antennas in the tables below have been approved for use with this module. Digi does not carry all of these antenna variants. Contact Digi Sales for available antennas.
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 162  Antennas approved for use with the XBee and XBee-PRO RF Modules (Cable loss is not required) OMNI-DIRECTIONAL ANTENNAS for All Available Channels Part Number Type (Description) Gain Application Min Separation Minimum Cable Loss/ Attenuation Required  29000313 Integral PCB antenna 0 dBi Fixed/Mobile 20 cm N/A 29000095 Dipole (Half-wave articulated RPSMA-4.5") 2.1 dBi Fixed/Mobile 20 cm N/A A24-HASM-450 Dipole (Half-wave articulated RPSMA-4.5") 2.1 dBi Fixed/Mobile 20 cm N/A A24-HABSM Dipole (Articulated RPSMA) 2.1 dBi Fixed 20 cm N/A A24-HABUF-P5I Dipole (Half-wave bulkhead mount U.FL s/ 5" pigtail) 2.1 dBi Fixed/Mobile 20 cm N/A A24-HASM-525 Dipole (Half-wave articulated RPSMA-5.25") 2.1 dBi Fixed 20 cm N/A A24-QI Monopole (Integrated Whip) 1.5 dBi Fixed/Mobile 20 cm N/A A24-F2NF Omni-Directional (Fiberglass base station) 2.1 dBi Fixed/Mobile 20 cm N/A A24-F3NF Omni-Directional (Fiberglass base station) 3.0 dBi Fixed/Mobile 20 cm N/A A24-F5NF Omni-Directional (Fiberglass base station) 5.0 dBi Fixed 20 cm N/A A24-F8NF Omni-Directional (Fiberglass base station) 8.0 dBi Fixed 2 m N/A A24-F9NF Omni-Directional (Fiberglass base station) 9.5 dBi Fixed 2 m N/A A24-F10NF Omni-Directional (Fiberglass base station) 10 dBi Fixed 2 m N/A A24-F12NF Omni-Directional (Fiberglass base station) 12 dBi Fixed 2 m N/A A24-W7NF Omni-Directional (Base station) 7.2 dBi Fixed 2 m N/A A24-M7NF Omni-directional (Mag-mount base station) 7.2 dBi Fixed 2 m N/A  Antennas approved for use with the XBee RF Modules (Cable loss is not required) OMNI-DIRECTIONAL ANTENNAS for All Available Channels Part Number Type (Description) Gain Application Min Separation Minimum Cable Loss/Power Reduction/Attenuation Required A24-F15NF Omni-Directional (Fiberglass base station) 15 dBi Fixed 2 m N/A
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 163  Antennas approved for use with the XBee RF Modules (Cable‐loss is not required.) PANEL CLASS ANTENNAS for All Available Channels Part Number Type (Description) Gain Application Min Separation Minimum Cable Loss/Power Reduction/Attenuation Required A24-P8SF Flat Panel 8.5 dBi Fixed 2 m N/A A24-P8NF Flat Panel 8.5 dBi Fixed 3 m N/A A24-P13NF Flat Panel 13 dBi Fixed 4 m N/A A24-P14NF Flat Panel 14 dBi Fixed 5 m N/A     Antennas approved for XBee RF Module Channels 11-25 YAGI CLASS ANTENNAS  for Channel 11-25 Part Number Type (Description) Gain Application Min Separation Minimum Cable Loss/Power Reduction/Attenuation Required A24-Y6NF Yagi (6 element) 8.8dBi Fixed 2 m N/A A24-Y7NF Yagi (7 element) 9.0 dBi Fixed 2 m N/A A24-Y9NF Yagi (9 element) 10.0 dBi Fixed 2 m N/A A24-Y10NF Yagi (10 element) 11.0 dBi Fixed 2 m N/A A24-Y12NF Yagi (12element) 12.0 dBi Fixed 2 m N/A A24-Y13NF Yagi (13 element) 12.0 dBi Fixed 2 m N/A A24-Y15NF Yagi (15 element) 12.5 dBi Fixed 2 m N/A A24-Y16NF Yagi (16 element) 13.5 dBi Fixed 2 m N/A A24-Y16RM Yagi (16 element, RPSMA connector) 13.5 dBi Fixed 2 m N/A A24-Y18NF Yagi (18 element) 15.0 dBi Fixed 2 m N/A A24-P15NF Flat Panel 15.0 dBi Fixed 2 m N/A A24-P16NF Flat Panel 16.0 dBi Fixed 2 m N/A A24-19NF Flat Panel 19.0 dBi Fixed 2 m N/A
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 164  Antennas approved for XBee RF Module Channel 26 YAGI CLASS ANTENNAS  for Channel 26 Part Number Type (Description) Gain Application Min Separation Minimum Cable Loss/Power Reduction/Attenuation Required A24-Y6NF Yagi (6 element) 8.8dBi Fixed 2 m N/A A24-Y7NF Yagi (7 element) 9.0 dBi Fixed 2 m N/A A24-Y9NF Yagi (9 element) 10.0 dBi Fixed 2 m N/A A24-Y10NF Yagi (10 element) 11.0 dBi Fixed 2 m N/A A24-Y12NF Yagi (12element) 12.0 dBi Fixed 2 m N/A A24-Y13NF Yagi (13 element) 12.0 dBi Fixed 2 m 0.5 dB A24-Y15NF Yagi (15 element) 12.5 dBi Fixed 2 m 1 dB A24-Y16NF Yagi (16 element) 13.5 dBi Fixed 2 m 2 dB A24-Y16RM Yagi (16 element, RPSMA connector) 13.5 dBi Fixed 2 m 7.5 dB A24-Y18NF Yagi (18 element) 15.0 dBi Fixed 2 m 9 dB A24-P15NF Flat Panel 15.0 dBi Fixed 2 m 4.5 dB A24-P16NF Flat Panel 16.0 dBi Fixed 2 m 10 dB A24-19NF Flat Panel 19.0 dBi Fixed 2 m 13 dB  * If using the RF module in a portable application (for example - if the module is used in a handheld device and the antenna is less than 20cm from the human body when the device is in operation): The integrator is responsible for passing additional SAR (Specific Absorption Rate) testing based on FCC rules 2.1091 and FCC Guidelines for Human Exposure to Radio Frequency Electromagnetic Fields, OET Bulletin and Supplement C. The testing results will be submitted to the FCC for approval prior to selling the integrated unit. The required SAR testing measures emissions from the module and how they affect the person.
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 165  Antennas approved for use with the XBee-PRO RF Module OMNI-DIRECTIONAL ANTENNAS for Channels 11 to 25 Part Number Type (Description) Gain Application Min Separation Minimum Cable Loss/ Attenuation Required A24-F15NF Omni-Directional (Fiberglass base station) 15 dBi Fixed 2 m 1 dB  PANEL CLASS ANTENNAS for Channels 11 to 25 Part Number Type (Description) Gain Application Min Separation Minimum Cable Loss/Attenuation Required A24-P8SF Flat Panel 8.5 dBi Fixed 2 m N/A A24-P8NF Flat Panel 8.5 dBi Fixed 2 m N/A A24-P13NF Flat Panel 13 dBi Fixed 2 m 4.3 dB A24-P14NF Flat Panel 14 dBi Fixed 2 m 5.3 dB A24-P15NF Flat Panel 15 dBi Fixed 2 m 6.3 dB A24-P16NF Flat Panel 16 dBi Fixed 2 m 7.3 dB A24-P19NF Flat Panel 19 dBi Fixed 2 m 10.3 dB  YAGI CLASS ANTENNAS  for Channels 11 to 25 Part Number Type (Description) Gain Application Min Separation Minimum Cable Loss/Attenuation Required A24-Y6NF Yagi (6 element) 8.8dBi Fixed 2 m N/A A24-Y7NF Yagi (7 element) 9.0 dBi Fixed 2 m N/A A24-Y9NF Yagi (9 element) 10.0 dBi Fixed 2 m N/A A24-Y10NF Yagi (10 element) 11.0 dBi Fixed 2 m 0.1 dB A24-Y12NF Yagi (12element) 12.0 dBi Fixed 2 m 1.1 dB A24-Y13NF Yagi (13 element) 12.0 dBi Fixed 2 m 1.1 dB A24-Y15NF Yagi (15 element) 12.5 dBi Fixed 2 m 1.6 dB A24-Y16NF Yagi (16 element) 13.5 dBi Fixed 2 m 2.6 dB A24-Y16RM Yagi (16 element, RPSMA connector) 13.5 dBi Fixed 2 m 2.6 dB A24-Y18NF Yagi (18 element) 15.0 dBi Fixed 2 m 4.1 dB
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 166             RF Exposure  WARNING: To satisfy FCC RF exposure requirements for mobile transmitting devices, a separation distance of 20 cm or more should be maintained between the antenna of this device and persons during device operation. To ensure compliance, operations at closer than this distance are not recommended. The antenna used for this transmitter must not be co-located in conjunction with any other antenna or transmitter.   The preceding statement must be included as a CAUTION statement in OEM product manuals in order to alert users of FCC RF Exposure compliance.
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 167   Europe (ETSI) The XBee RF Module (excluding the PRO) has been certified for use in several European countries. For a complete list, refer to www.digi.com If the XBee RF Modules are incorporated into a product, the manufacturer must ensure compliance of the final product to the European harmonized EMC and low-voltage/safety standards. A Declaration of Conformity must be issued for each of these standards and kept on file as described in Annex II of the R&TTE Directive. Furthermore, the manufacturer must maintain a copy of the XBee user manual documentation and ensure the final product does not exceed the specified power ratings, antenna specifications, and/or installation requirements as specified in the user manual. If any of these specifications are exceeded in the final product, a submission must be made to a notified body for compliance testing to all required standards. OEM Labeling Requirements The 'CE' marking must be affixed to a visible location on the OEM product. CE Labeling Requirements  The CE mark shall consist of the initials "CE" taking the following form: account of the nature of the apparatus.  marking must be affixed visibly, legibly, and indelibly. Restrictions France: Outdoor use limited to 10 mW EIRP within the band 2454-2483.5 MHz.  Norway: Norway prohibits operation near Ny-Alesund in Svalbard. More information can be found at the Norway Posts and Telecommunications site (www.npt.no).
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 168  Declarations of Conformity Digi has issued Declarations of Conformity for the XBee RF Modules concerning emissions, EMC and safety. Files can be obtained by contacting Digi Support. Important Note: Digi does not list the entire set of standards that must be met for each country. Digi customers assume full responsibility for learning and meeting the required guidelines for each country in their distribution market. For more information relating to European compliance of an OEM product incorporating the XBee RF Module, contact Digi, or refer to the following web sites: CEPT ERC 70-03E - Technical Requirements, European restrictions and general requirements: Available at www.ero.dk/. R&TTE Directive - Equipment requirements, placement on market: Available at www.ero.dk/. Approved Antennas When integrating high-gain antennas, European regulations stipulate EIRP power maximums. Use the following guidelines to determine which antennas to design into an application.  XBee RF Module  The following antennas types have been tested and approved for use with the XBee Module: XBee® ZB  RF Modules © 2010 Digi International, Inc. 151  Antenna Type: Yagi  RF module was tested and approved with 15 dBi antenna gain with 1 dB cable-loss (EIRP Maximum of 14 dBm). Any Yagi type antenna with 14 dBi gain or less can be used with no cable-loss.  Antenna Type: Omni-Directional  RF module was tested and approved with 15 dBi antenna gain with 1 dB cable-loss (EIRP Maximum of 14 dBm). Any Omni-Directional type antenna with 14 dBi gain or less can be used with no cable-loss.  Antenna Type: Flat Panel  RF module was tested and approved with 19 dBi antenna gain with 4.8 dB cable-loss (EIRP Maximum of 14.2 dBm). Any Flat Panel type antenna with 14.2 dBi gain or less can be used with no cable-loss. XBee RF Module The following antennas have been tested and approved for use with the embedded XBee RF Module:  - Dipole (2.1 dBi, Omni-directional, Articulated RPSMA, Digi part number A24-HABSM)  - PCB Antenna (0 dBi)
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 169
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 170  Canada (IC) Labeling Requirements  Labeling requirements for Industry Canada are similar to those of the FCC. A clearly visible label on the outside of the final product enclosure must display the following text:  Contains Model XBee Radio, IC: 1846A-XBS2C  The integrator is responsible for its product to comply with IC ICES-003 & FCC Part 15, Sub. B - Unintentional Radiators. ICES-003 is the same as FCC Part 15 Sub. B and Industry Canada accepts FCC test report or CISPR 22 test report for compliance with ICES-003.  If it contains an XBee-PRO (S2) RF Module, the clearly visible label on the outside of the final product enclosure must display the following text:  Contains Model XBee-PRO Radio, IC: 1846A-XBPS2C  Transmitters with Detachable Antennas This device has been designed to operate with the antennas listed in the previous table and having a maximum of 17.5 dB. Antennas not included in this list or having a gain greater than 17.5 dB are strictly prohibited for use with this device. The required antenna impedance is 50 ohms. Detachable Antenna To reduce potential radio interference to other users, the antenna type and gain should be so chosen that the equivalent, istropically radiated power (e.i.r.p.) is not more than permitted for successful communication. Australia (C-Tick) These modules comply with requirements to be used in end products in Australia. All products with EMC and radio communications must have a registered C-Tick mark. Registration to use the compliance mark will only be accepted from Australian manufacturers or importers, or their agent, in Australia. In order to have a C-Tick mark on an end product, a company must comply with a or b below. a. have a company presence in Australia.  b. have a company/distributor/agent in Australia that will sponsor the importing of the end product. Contact Digi for questions related to locating a contact in Australia.
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 171  13. Migrating from XBee S2B to XBee S2C The XBee S2C and XBee-PRO S2C are designed to be compatible with the XBeeS2B and XBee-PRO S2B.   The S2C modules have all the features of the S2B modules and offer the increased feature set described in this users guide.  For further information on the S2B see the XBee®/XBee-PRO® ZB RF Modules www.digi.com. Pin Mapping Mapping of the S2C pins to the S2B pins is shown in the table below.  The pin names are from the S2C SMT module. S2C Pin # Name S2B Pin #  S2C Pin # Name S2B Pin # 1 GND    20 JTDI   2 VCC 1  21 JTMS/SWDIO   3 DOUT/DIO13 2  22 GND   4 Din/nConfig/DIO14 3  23 reserved   5 DIO12 4  24 DIO4 11 6 nRESET 5  25 nCTS/DIO7 12 7 RSSI PWM/ DIO10 6  26 On /SLEEP/DIO9 13 8 PWM1/DIO11 7  27 VREF 14 9 reserved 8  28 Associate/DIO5 15 10 nDTR/SLEEP_RQ/DIO8 9  29 nRTS/DIO6/SCLK2 16 11 GND 10  30 AD3/DIO3 17 12 SPI_Attn/nBOOTMODE    31 AD2/DIO2 18 13 GND    32 AD1/DIO1 19 14 SPI_CLK/DIO18    33 AD0/DIO0 20 15 SPI_nSSEL/DIO17    34 reserved   16 SPI_MOSI/DOI16    35 GND   17 SPI_MOSO/DOI15    36 RF   18 JTCK/SWCLK    37 reserved   19 JTDO/SWO        Mounting One of the important differences between the S2C and S2B modules is the way they mount to the PCB.  The S2B is designed with through hole pins, while the S2C is designed with Surface Mount Technology (SMT).  As such different mounting techniques may be required. Digi International has designed a footprint which will allow either module to be attached to a PCB.  The layout is shown below.
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 172   The round holes in the diagram are for the Through Hole XBee, and the semi-oval pads are for the Survace Mount (S2C) XBee.  Pin 1 of the Through Hole XBee in the diagram is lined up with pin 1 of the Surface Mount S2C, but the pins are actually offset by one pad (see Pin Mapping above).  By using diagonal traces to connect the appropriate pins, the layout will work for both modules. Information on attaching the S2C SMT module is included in Chapter 14 below.
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 173  14. Manufacturing Information The XBee S2C and XBee-PRO S2C are designed for surface mount on the OEM PCB.  The S2C modules are designed with castellated pad to allow for easy solder attach inspection.  The pads are all located on the edge of the module, so no hidden solder joints are used with these modules. Recommended Solder Reflow Cycle The recommended solder reflow cycle is shown below.   The Chard shows the temperature setting and the time to reach the temperature.  The cooling cycle is not shown.  Time (sec) Temperature (°C) 30 65 60 100 90 135 120 160 150 195 180 240 210 260  The maximum temperature should not exceed 260 °C.   The module will reflow during this cycle, and must not be reflowed with the shield down.  Care should be taken not to jar the module while the solder is molten, as parts inside the module can be removed from their required locations. Hand soldering is possible and should be done in accordance with approved standards.
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 174  Recommended Footprint In order to surface mount the XBee S2C modules, it is recommended that you use the PCB footprint shown below.  The solder footprint should be matched to the copper pads, but may need to be adjusted depending on the specific needs of assembly and product standards. While the underside of the XBee S2C/XBee-PRO S2C do not contain any holes, and is mostly coated with solder resist, it is recommended that the copper layer directly below the module be left open to avoid unintended contacts.  These modules have a ground plane in the middle on the back side for shielding purposes which can be  affected  by copper traces directly under the module. Flux and Cleaning clean step and insure that unwanted residual flux in not left under the module where it is difficult to remove.  In addition:
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 175   Cleaning with liquids can result in liquid remaining under the shield or in the gap between the module and OEM PCB.  This can lead to unintended connections between the pads of the module.  The residual moisture and flux residue under the module are not easily seen during an inspection process. module operation. Reworking The module may be removed from the OEM PCB by the use of a hot air rework station, or hot plate.  Care should be taken not to overheat the module.  During rework, the module temperature may rise above its internal solder melting point and care should be taken not to dislodge internal components from their intended positions. Rework should never be performed on the module itself.  The module has been optimized to give the best possible performance, and reworking the module itself will void warranty coverage.
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 176  15. Warranty Information 1-Year Warranty XBee RF Modules from Digi International, Inc. (the "Product") are warranted against defects in materials and workmanship under normal use, for a period of 1-year from the date of purchase. In the event of a product failure due to materials or workmanship, Digi will repair or replace the defective product. For warranty service, return the defective product to Digi International, shipping prepaid, for prompt repair or replacement. The foregoing sets forth the full extent of Digi International's warranties regarding the Product. Repair or replacement at Digi International's option is the exclusive remedy. THIS WARRANTY IS GIVEN IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, AND DIGI SPECIFICALLY DISCLAIMS ALL WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL DIGI, ITS SUPPLIERS OR LICENSORS BE LIABLE FOR DAMAGES IN EXCESS OF THE PURCHASE PRICE OF THE PRODUCT, FOR ANY LOSS OF USE, LOSS OF TIME, INCONVENIENCE, COMMERCIAL LOSS, LOST PROFITS OR SAVINGS, OR OTHER INCIDENTAL, SPECIAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OR INABILITY TO USE THE PRODUCT, TO THE FULL EXTENT SUCH MAY BE DISCLAIMED BY LAW. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES. THEREFORE, THE FOREGOING EXCLUSIONS MAY NOT APPLY IN ALL CASES. This warranty provides specific legal rights. Other rights which vary from state to state may also apply.
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 177  Appendix A:  Definitions Definitions ZigBee Node Types  Coordinator  A node that has the unique function of forming a network. The coor-dinator is responsible for establishing the operating channel and PAN ID for an entire network. Once established, the coordinator can form a network by allowing routers and end devices to join to it. Once the network is formed, the coordinator functions like a router (it can participate in routing packets and be a source or destination for data packets).  -- One coordinator per PAN  -- Establishes/Organizes PAN  -- Can route data packets to/from other nodes -- Can be a data packet source and destination -- Mains-powered Refer to the XBee coordinator section for more information.  Router  A node that creates/maintains network information and uses this information to determine the best route for a data packet. A router must join a network before it can allow other routers and end devices to join to it. A router can participate in routing packets and is intended to be a mains-powered node.  -- Several routers can operate in one PAN -- Can route data packets to/from other nodes -- Can be a data packet source and destination  -- Mains-powered Refer to the XBee router section for more information.  End device  End devices must always interact with their parent to receive or transmit dataThey are intended to sleep periodically and therefore have no routing capacity. An end device can be a source or destination for data packets but cannot route packets. End devices can be battery-powered and offer low-power operation.  -- Several end devices can operate in one PAN -- Can be a data packet source and destination  -- All messages are relayed through a coordinator or router -- Lower power modes
XBee®/XBee‐PRO® SMT ZB RF Modules  © 2010 Digi International, Inc.   Page 178  ZigBee Protocol PAN  Personal Area Network - A data communication network that includes a coordinator and one or more routers/end devices.  Joining The process of a node becoming part of a ZigBee PAN. A node becomes part of a network by joining to a coordinator or a router (that has previously joined to the network). During the process of joining, the node that allowed joining (the parent) assigns a 16-bit address to the joining node (the child).  Network Address  The 16-bit address assigned to a node after it has joined to another node. The coordinator always has a network address of 0.  Operating Channel  The frequency selected for data communications between nodes. The operating channel is selected by the coordinator on power-up.  Energy Scan  A scan of RF channels that detects the amount of energy present on the selected channels. The coordinator uses the energy scan to determine the operating channel.  Route Request  Broadcast transmission sent by a coordinator or router throughout the network in attempt to establish a route to a destination node.  Route Reply  Unicast transmission sent back to the originator of the route request. It is initiated by a node when it receives a route request packet and its address matches the Destination Address in the route request packet.  Route Discovery  The process of establishing a route to a destination node when one does not exist in the Routing Table. It is based on the AODV (Ad-hoc On-demand Distance Vector routing) protocol.  ZigBee Stack  ZigBee is a published specification set of high-level communication protocols for use with small, low-power modules. The ZigBee stack provides a layer of network functionality on top of the 802.15.4 specification. For example, the mesh and routing capabilities available to ZigBee solutions are absent in the 802.15.4 protocol.

Navigation menu