Digigram PCXIP Multichannel Sound Card User Manual Manual

Digigram Multichannel Sound Card Manual

Manual.pdf

PCX-IP LW881e, PCX-IP LW1221eUser’s manualPCX-IP LW881ePCX-IP LW1221eProfessional Multichannel Sound Cards with Livewire connectivity  User’s manual1
PCX-IP LW881e, PCX-IP LW1221eUser’s manualFor technical support,please contact your system supplier.Digigram S.A.Parc de Pré Milliet, 38330 Montbonnot - FRANCETel: +33 (0)4 76 52 55 01• Fax: +33 (0) 4 76 52 53 07• E-mail: info@digigram.comDigigram Asia Pte Ltd.60 Albert Street - #19-11OG Albert Complex Singapore 189969, SingaporeTel : +65 6291 2234 • Fax : +65 6291 3433 • E-mail : info_asia@digigram.com2
PCX-IP LW881e, PCX-IP LW1221eUser’s manualTable of ContentsINFORMATION FOR THE USERIMPORTANT NOTICEFEATURESPCX-IP LW881 main hardware featuresPCX-IP LW1221 main hardware featuresMain software featuresREQUIREMENTSSupported operating systemsMinimum hardware requirementsSoftware requirementsHARDWARE INSTALLATIONInstalling the cardInterrupt and memory addressSOFTWARE INSTALLATIONStandard installationX-Topology installationASIO driver configurationWave driver configurationRemoving the driverHOW TO CHECK THE INSTALLATIONTHE “DHS” CONTROL PANELCONFIGURATION OF LIVEWIRE PARAMETERSConfiguration of sourcesConfiguration of destinationsConfiguration of GPIOsVu_metersQosSystem parameters3
PCX-IP LW881e, PCX-IP LW1221eUser’s manualSPECIFICATIONS-ConfigurationInputs/OutputsSampling frequencyConnectorsDevelopment environments & supported operating systemsAPPENDICESSchematic diagramsGPIOs connector pinout4
PCX-IP LW881e, PCX-IP LW1221eUser’s manualINFORMATION FOR THE USERThis device complies w ith part 15 of FCC rules. Operation is subject to the follow ing tw o conditions: (1) This device may not cause harmful                                             interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.This equipment has been tested and found to comply w ith the limits for a CLASS B digital device, pursuant to Part 15 of the FCC Rules.                                                 These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment                               generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance w ith the instructions contained in this                                         data sheet, may cause harmful interference to radio and television communications. How ever, there is no guarantee that interference w ill                                   not occur in a particular installation.If this equipment does cause harmful interference to radio or television reception, w hich can be determined by turning the equipment off                                       and on, the user is encouraged to try to correct the interference by one or more of the follow ing measures:* reorient or relocate the receiving antenna* increase the separation betw een the equipment and the receiver* connect the equipment into an outlet on a circuit different from that of the receiver* consult the dealer or an experienced audio television technician.Note: Connecting this device to peripheral devices that do not comply with CLASS B requirements or using an unshielded peripheraldata cable could also result in harmful interference to radio or television reception. The user is cautioned that any changes ormodifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.To ensure that the use of this product does not contribute to interference, it is necessary to use shielded I/O cables.Warning:Electrostatic discharge (ESD) can damage several components on the board. To avoid such damage in handling the board, take the                                     following precautions:Bring the device and everything that contacts it to ground potential by providing a conductive surface and discharge paths. As a minimum,                                         observe these precautions:●Disconnect all power and signal sources.●Place the device on a grounded conductive work surface.●Ground yourself via a grounding wrist strap or by holding a grounded object.●Ground any tool that will contact the device.Due to the reduced length of the PCI EXPRESSTM bus connector and the resulting lack of mechanical stability, we strongly advise againsttransporting the PCIe® card(s) installed in a computer, unless its chassis or case provides a dedicated support to keep the card securely inplace in order to avoid physical damage.IMPORTANT NOTICEThis card has been tested and found to comply with the following standards:●International: CISPR22 Class B●Europe: EMC 89/336/CEE (1992) specifications●United States: FCC Rules-Part 15-Class B (digital device)In order to guarantee compliance with the above standards in an installation, the following must be done:●the provided cable must not be modified●additional cables used must have their respective shield connected to each extremity5
PCX-IP LW881e, PCX-IP LW1221eUser’s manualFEATURESPCX-IP LW881e and PCX-IP LW1221e are sound cards for use with Axia Livewire™ systems, with PCI EXPRESST M (PCIe®) businterface. They are in PCI EXPRESSTM x1 format and can thus be plugged into any PCIe® slot (x1, x4, x8, x16).PCX-IP LW881 main hardware features●1 RJ-45 Ethernet port allowing for extraction of up to 8 mono channels from the Livewire network, and insertion of up to 8 monochannels in the Livewire network●1 Sub-D 9 pin connector for 5 physical  GPI / 5 physical  GPO transmitted through the Livewire network.●48 kHz sampling frequency●Several cards can be plugged in one PCPCX-IP LW1221 main hardware features●1 RJ-45 Ethernet port allowing for extraction of up to 2 mono channels from the Livewire network, and insertion of up to 12 monochannels in the Livewire network●1 Sub-D 9 pin connector for 5 physical  GPI / 5 physical  GPO transmitted through the Livewire network.●48 kHz sampling frequency●Several cards can be plugged in one PCMain software features●Real-time, simultaneous record and playback in PCM (8, 16 and 24 bits) as well as in MPEG Audio Layer I, Layer II and Layer III*,Float IEEE754 conversion supported (with 24-bit fixed-point dynamic range)●When using the Digigram np SDK, real-time mixing of several PCM and MPEG audio streams per output channel, direct monitoring,level adjustment, panning, cross-fades, punch-in/punch-out, scrubbing, time-stretching, pitch-shifting, 3-band parametric equalizer,Maximizer, format and frequency conversions.●Low latency WDM DirectSound, Wave, and ASIO drivers. Under DirectSound and ASIO, the cards operate in PCM mode only(nevertheless, an application can integrate coders/decoders on the host PC).Under Wave, HR boards can operate in both PCM and MPEG (layer 1 and layer 2).* MPEG Layer III play-only on DSP MPEG Layer III recording on the host computer is available through Digigram’s PC Codec using the np SDK6
PCX-IP LW881e, PCX-IP LW1221eUser’s manualREQUIREMENTSSupported operating systemsPCX Livewire cards run under the following operating systems:●32-bit OS: Windows XP, Windows Server 2003, Windows Vista, Windows Server 2008, Windows 7, Windows 8●64-bit OS: Windows Server 2008, Windows 7, Windows 8.Minimum hardware requirementsOne PCI EXPRESS™ (PCIe®) slot per card (x1, x4, x8, x16).Required CPU power and memory mainly depend on the operating system and on the audio application used.Software requirementsTo use your card under Windows, please install the driver from the HR Runtime package version 1.74 or higher. This package includes:●a Digigram np driver enabling OEM applications to best capitalize on the on-board features (MPEG, mixing, time-scaling,cross-fades,...).●a WDM DirectSound driver (32 bits or 64 bits according to the OS)●a Wave driver (32 bits, installation optional)●an ASIO driver (32 bits and 64 bits, installation optional)7
PCX-IP LW881e, PCX-IP LW1221eUser’s manualHARDWARE INSTALLATIONDue to the reduced length of the PCI EXPRESS™ bus connector and the resulting lack of mechanical stability, we strongly advise                                       against transporting the PCIe® card(s) installed in a computer, unless its chassis or case provides a dedicated support to keep the                                       card securely in place in order to avoid physical damage.The card has to be installed in the computer prior to installing its driver.Installing the cardGently plug the card in a free PCI slot and press it down to position it firmly. Tighten the screw.Interrupt and memory addressHardware interrupt and addresses are automatically set up at start-up by the PCI PnP BIOS.8
PCX-IP LW881e, PCX-IP LW1221eUser’s manualSOFTWARE INSTALLATIONThe installation of the driver package requires administrator rights on your computer.Please visit the Digigram web site at www.digigram.com for the most recent driver.In case you run a specific application developed or installed by a Digigram Partner, this application might require the use of a specific                                           driver version. In this case, make sure that the updated driver has been approved by your supplier.The following procedure installs the ‘Digigram Hardware Settings’ control panel. This application allows the configuration of the                               hardware resources of Digigram cards for all audio applications. The DHS allows for instance to adjust input and output digital gains                                       and direct monitoring of inputs on ouputs.With the inputs and outputs controlled by the DHS application, the controls available through the DirectSound control panel get invalid :●Volume control for input●Volume control for outputUnder Windows XP and Server 2003 you may also install the driver without installing the DHS control panel, and in this case more                                           controls are available through the DirectSound control panel:●Volume control for input●Wave control●Monitoring control●Digital input level●Digital output levelTo do so, install the driver with the command line: “setup x_topology” (not available under Windows Vista). For detailed                                 information, please refer to the dedicated document on our web site.Standard installation●Shut down your computer and insert your PCX card.●Restart your computer.●Click on Cancel if the “Found New Hardware Wizard” appears.●Double-click on the HR Runtime driver package icon to launch the driver installation.A welcome message is displayed, click Next to continue.The “License Agreement” window appears: read it, and click on“I accept the terms in the license agreement” to approve it.9
PCX-IP LW881e, PCX-IP LW1221eUser’s manualDo the same in the next License agreement window for Virtual PCX and PC Codec                           Legal Notice.In the “Custom Setup” window, the “Drivers for the HR b oards” that can be                        installed are listed.The WDM DirectSound driver and the Digigram np driver are automatically installed.Items that can be optionally installed are:● Digigram Hardware Settings panel (DHS): installed by default. The DHS controlpanel allows for adjusting digital level for input/ouptut channels, and monitoringparameters. These settings cannot be controlled through DirectSound controls.If the DHS is not installed, these settings are accessible for the DirectSoundcontrols.This item is not selectable under Windows XP (see X-Topology installation)● Asio driver: installed by default● Wave MME driver: not installed by default● VX devices visible by default (to be selected in case the np based application isnot designed to detect the VX card- the use of this option is specified by yoursoftware application provider).Click on Next once you have made your selection of items to be installed.In the Window “Ready to Install the Program”, click on Install to start copying the                          files.In case the User Account Control window prompts you to authorize the driver                       installation, click on OK.Driver files are then installed on the computer.In case the “Digital Signature Not Found” message appears because                   non-Microsoft software is about to be installed, click on Continue.10
PCX-IP LW881e, PCX-IP LW1221eUser’s manualClick Finish to complete the driver installation.X-Topology installationUnder Windows XP and Windows Server 2003, it is possible to install the drivers without the DHS, so that controls like digital levels andmonitoring are accessible from the DirectSound controls. The driver package must then be installed as follows: MsiExec.exe /I abcd.msiX_TOPOLOGY=1, where “abcd.msi” is to be replaced by the name of the driver package.ASIO driver configurationNote: Under 64-bit operating systems, and for most current ASIO applications (e.g. Cubase, Nuendo, etc...) you have                               the choice between a 32-bit version and a 64-bit version when installing them. The 64-bit package of HR Runtime                                   installs both a 32-bit ASIO driver and a 64-bit ASIO driver.To use the ASIO driver on your PCX sound card, the option “PCM only” has to be enabled from  the Digigram control panel (CPL). Toaccess this control panel, go to <Start>, <Programs>, <Digigram>, <Digigram Control Center>.To launch the ASIO control panel, go to <Start>, <Programs>, <Digigram>, <Digigram ASIO HR Settings>.It allows to:● set/modify the size of ASIO buffers (= latency adjustment)● select the number of bits per sample (16, 24, 32)● select the LTC frame rate● select the I/Os to be used by the application(s)● enable/disable the hardware monitoring control● enable/disable the multi-client mode. When enabled, severalapplications can access different channels of the card (butone channel cannot be used by several applications)For more information on this ASIO control panel, to refer to itsonline help.11
PCX-IP LW881e, PCX-IP LW1221eUser’s manualWave driver configurationIn the case the software application exclusively manages PCM audio through the Wave MME interface, the latency of the Wave driver                                       can be optimized by enabling the option “PCM only” in the Digigram control panel (CPL). To access this control panel, go to <Start>,                                          <Programs>, <Digigram>, <Digigram Control Center>.For detailed information on how to use the Digigram control panel, please refer to its online help (“? Help” button).Removing the driverOpen the Windows Control Panel and double-click on the Add/Remove Software icon or  Programs and Features icon,depending on the Windows flavour.● Select “Digigram HR Runtime …”, and Change/Remove.● Select Remove in the HR Runtime window.● Follow the instructions to finish to remove the driver.HOW TO CHECK THE INSTALLATIONOnce the card and the driver have been installed according to the procedure described in this manual, you can check that the PCX cardis properly installed and works fine as follows.●From <Start> <Programs> <Digigram>, select <Digigram Control Center>.●Select the ‘General Information’ tab.In the “Modules Information” window, you can see the HR Runtime modules that have been installed, and their versions.●Select the ‘Diagnostics’ tab to display the installed card(s).12
PCX-IP LW881e, PCX-IP LW1221eUser’s manualIf the card is not displayed:●Make sure that during the HR runtime installation the “Driver for the HR boards” has been selected in the “Select components”window.●Open the Windows Device Manager (from Control Panel, System). The card should be listed in “Sound” or “Sound, video, andgames” controllers. If it is listed with no warning symbol, the card is well recognized by the system. In case there is a warningsymbol : make sure that the card is correctly inserted in the PCI slot, and screwed on the PC chassis.●If necessary, uninstall the HR runtime package as described in this manual, and re-install it.If the card is displayed:●Right click on the icon of the card.●Select ‘Diagnostics’, and ‘Play Sine’. This plays in loop a sine signal on all the output channels of the card. You can also select ‘Playfile’ to play in loop a file of your choice (PCM only).If the playback is correct, the card is correctly installed and works.●To stop the playback, right click on the card icon, and select ‘Stop Activities’.The DirectSound devices associated to the card are displayed from the Windows Control Panel, Sound.● Select tab “Audio”, Default device (Playback device, Recording device).Available DirectSound devices that can be selected from a DirectSound application are:DirectSound playback devicesDirectSound recording devicesOUT 1+2 (Digigram PCX-IP LW881e)    / OUT 1+2 (Digigram PCX-IP LW1221e)OUT 3+4 (Digigram PCX-IP LW881e)    / OUT 3+4 (Digigram PCX-IP LW1221e)OUT 5+6 (Digigram PCX-IP LW881e)    / OUT 5+6 (Digigram PCX-IP LW1221e)OUT 7+8 (Digigram PCX-IP LW881e)    / OUT 7+8 (Digigram PCX-IP LW1221e)OUT 5.1 (Digigram PCX-IP LW881)       / OUT 9+10 (Digigram PCX-IP LW1221e)OUT 7.1 (Digigram PCX-IP LW881)       / OUT 11+12 (Digigram PCX-IP LW1221e)                                                              / OUT 5.1 (Digigram PCX-IP LW1221e)                                                              /  OUT 7.1 (Digigram PCX-IP LW1221e)                                                              /  OUT 5.1+2 (Digigram PCX-IP LW1221e)IN 1+2 (Digigram PCX-IP LW881) / (Digigram PCX-IP LW1221e)IN 3+4 (Digigram PCX-IP LW881)IN 5+6 (Digigram PCX-IP LW881)IN 7+8 (Digigram PCX-IP LW881)IN 5.1 (Digigram PCX-IP LW881)IN 7.1 (Digigram PCX-IP LW881)IN 5.1+2 (Digigram PCX-IP LW881)If the Wave driver has been installed, and for OS older than Windows 7:● Go to menu <Start>, <Settings>, <Control panel>, <Sound and Multimedia>, tab “Audio”, Default device (Playback device,Recording device). The card’s channels can be selected. The card can be used with any Wave application.Available Wave  MME devices that can be selected from a Wave MME based application are:Wave playback devicesWave recording devicesPCX-IP LW881e (Wave)         /     PCX-IP LW1221e (Wave)PCX-IP LW881e (Wave)         /     PCX-IP LW1221e (Wave)PCX-IP LW881e (Wave)         /     PCX-IP LW1221e  (Wave)PCX-IP LW881e (Wave)         /     PCX-IP LW1221e (Wave)PCX-IP LW881e 5.1 (Wave)    /     PCX-IP LW1221e (Wave)PCX-IP LW881e 7.1 (Wave)    /     PCX-IP LW1221e (Wave)PCX-IP LW881e 5.1+2  (Wave) /   PCX-IP LW1221e 5.1 (Wave)                                             /    PCX-IP LW1221e 7.1 (Wave)                                             /    PCX-IP LW1221e 5.1+2 (Wave)                                             /    PCX-IP LW1221e 7.1+2 (Wave)PCX-IP LW881e (Wave)         / PCX-IP LW1221e (Wave)PCX-IP LW881e (Wave)PCX-IP LW881e (Wave)PCX-IP LW881e (Wave)PCX-IP LW881e 5.1 (Wave)PCX-IP LW881e 7.1 (Wave)PCX-IP LW881e 5.1+2  (Wave)When opening the Digigram Wave Mixer application, only one vu-meter is displayed on the selected channel mixer.13
PCX-IP LW881e, PCX-IP LW1221eUser’s manualIf the ASIO driver has been installed, the card is visible from the ASIO control panel, and from any ASIO application.To launch the ASIO control panel, go to <Start>, <Programs>, <Digigram>, <Digigram ASIO HR Settings>.14
PCX-IP LW881e, PCX-IP LW1221eUser’s manualTHE “DHS” CONTROL PANELDigigram Hardware Settings (DHS) is an application allowing to configure the hardware resources of Digigram cards for all audio                                   applications using them.The parameters of an resource being managed by the DHS application can not be modified from another applications. To enable an                                       audio application to modify a Digigram card resource, this resource must not be managed by the DHS.Note: As soon as a resource of a card is managed by the DHS, the clock selection of this card must be defined in the                                               DHS.The DHS allows to:●adjust digital gains of input and output signals●mute / unmute input and output signals●Select the input monitored on an output (zero latency hardware monitoring)●Set the monitoring gainsFor more detailed information on how to use this control panel, please refer to its on-line help.15
PCX-IP LW881e, PCX-IP LW1221eUser’s manual16
PCX-IP LW881e, PCX-IP LW1221eUser’s manualCONFIGURATION OF LIVEWIRE PARAMETERSTo be able to configure the Livewire parameters from the WEB pages of the PCX card, it is necessary to connect a NIC card of the                                                 computer to the Livewire network.The PCX card default IP address is: 192.168.0.100.Enter this IP address in your WEB browser address bar.The following page is displayed.Configuration of sourcesConfiguring Livewire sources is necessary to assign the playback devices of the PCX-IP  to Livewire inputs.PCX-IP 881e features 8 mono playback devices to be injected to 8 Livewire mono inputs.PCX-IP 1221e features 12 mono playback devices to be injected to 12 Livewire mono inputs.To configure the Livewire sources, click on “Livewire Sources”. The following page is displayed.From this page, you can :● Give a name to each local input to the Livewire node: Source Name (16 printable characters max). This can typically be thename given to a channel of a playback application running on the PCX-IP card (ex: PCX-IP Player 1).● Assign a livewire channel to each source: Channel. The channel number must be unique, and between 1 and 32767.● Set parameters for each source:- Shareable:- Stream Mode: Select “Live Stereo” for streams where low latency is required, and select “Standard Stereo” otherwise.Configuration of destinationsConfiguring Livewire Destinations is necessary to assign the recording devices of the PCX-IP  to the Livewire outputs.PCX-IP 881e features 8 mono recording devices receiving 8 Livewire mono outputs.PCX-IP 1221e features 2 mono recording devices treceiving 2 Livewire mono outputs.To configure the Livewire Destinations, click on “Destinations”. The following page is displayed.17
PCX-IP LW881e, PCX-IP LW1221eUser’s manualFrom this page, you can :● Give a name to each local output to the Livewire node: Name (16 printable characters max). This can typically be the namegiven to a channel of a recording application running on the PCX-IP card (ex: PCX-IP Rec1).● Select one of the available Livewire channels to be extracted and assign to the corresponding PCX-IP input.● Set the Type for each selected livewire channel:- From source:- To source:Configuration of GPIOsVu_metersThis page displays the vu-meters of the signals available on the Livewire sources (typically audio coming from software players) anddestinations (typically Livewire channels to be recorded by software recorders).Click on “Meters”  to display the vu-meters page.18
PCX-IP LW881e, PCX-IP LW1221eUser’s manualQosIn most of the cases, the parameters of the “QoS” page should not be changed. In case you need to modify them, you may refer todocuments available from Axia WEB site.System parametersThe “System” page allows setting the network parameters of the PCX-IP card. These parameters are the usual parameters of anetwork interface like:● Host name: used to identify the PCX-IP card on the network.● Network address: IP address of the PCX-IP card on the network. There must be no other node with the same IP address.● Netmask: mask to identify the sub network the nodes belongs to● ....19
PCX-IP LW881e, PCX-IP LW1221eUser’s manualSPECIFICATIONSConfigurationPCX-IP LW881e / PCX-IP LW12121eBus/Form atPCI Express™ (PCIe x1) (x2, x4, x8, x16 compatible)Digital Signal ProcessorMotorola 56321 at 240 MHzRAM512 kWordsSize168 mm x 111 mm x 20 mmPow er requirements(+3.3V/+5V / +12V / –12V)2.5 A / 0 A / 0.1 A / 0 AOperating: temp / hum idity(non-condensing)0°C/+50°C . 5%/95%Storage: temp / hum idity(non-condensing)-5°C/+70°C . 0%/95%Inputs/OutputsPCX-IP LW881ePCX-IP LW12121eLivew ire input m ono channels82Livew ire output mono channels812Programm able input/output digitalgain from –110 dB à +18 dB from –110 dB à +18 dBGeneral Purpose Inputs & Outpust55Sampling frequencySampling frequencies available48 kHzConnectorsEthernetRJ-45GPIOSub-D 15 pinsDevelopment environments & supported operating systemsDigigram managem entnp SDK (HR Runtime, PCM & MPEG)Other APIsDirectSound, DirectKS (PCM)ASIO (PCM)Wave * (PCM & MPEG Layer I & II)1OS supportedWindow s XP, Window s Server 2003, Window s Server 2008,Window s 7, Window s 81  * Windows XP and Server 2003 only; for Windows Vista, a Wave driver is available on request.20
PCX-IP LW881e, PCX-IP LW1221eUser’s manualAPPENDICESSchematic diagrams GPIOs connector pinoutThe pinout of the GPIOs on the Sub-D 15 pin-connector of the PCX card is identical to the GPIO connector used in Axia nodes.21