Digital Monitoring PC0103 LOW POWER TRANSMITTER User Manual USERS MANUAL
Digital Monitoring Products Inc LOW POWER TRANSMITTER USERS MANUAL
USERS MANUAL
INSTALLATION GUIDE 1139 Bill Trap Transmitter Description The 1139 Bill Trap is a wireless transmitter designed to provide a silent alarm in retail and banking cash drawers by trapping one bill below a stack of bills. When the trapped bill is removed, a panic alarm is sent. To reduce the possibility of a false alarm, a delay can be programmed to provide time to replace the bill should it be accidentally removed. The 1139 Bill Trap operates with the XR100 and XR500 Series Command Processor™ panels using the 1100X Receiver or with the XRSuper6, XR20, and XR40 Command Processor™ panels using the 1100D Receiver. What is Included The 1139 Bill Trap Transmitter includes the following items: • One Bill Trap with DMP wireless transmitter installed • Two CR2450 3.0V lithium coin cell batteries • Velcro mounting strip • Zone name and number label • Serial number label Bill Trap Transmitter Housing Bill Trap Slide one end of bill underneath clip to hold in place. Transmitter Serial Number For your convenience, an additional pre-printed serial number label is included. Record the serial number or place the pre-printed serial number label on the panel programming sheet. This number is required during programming. As needed, use the zone name and number label to identify a specific transmitter. Programming the Bill Trap in the Panel Bill Trap Housing Base Figure 1: 1139 Bill Trap Refer to the XR500 Series Programming Guide (LT-0679), XR100 Series Programming Guide (LT-0896), or the XRSuper6/XR20/XR40 Programming Guide (LT-0305) as needed. Program the device as a zone in Zone Information during panel programming. At the Serial Number prompt, enter the eight-digit serial number. Continue to program the zone as directed in the panel programming guide. Note: When a receiver is installed, powered up, or the panel is reset, the supervision time for transmitters is reset. If the receiver has been powered down for more than one hour, wireless transmitters may take up to an additional hour to send a supervision message unless tripped, tampered, or powered up. This operation extends battery life for transmitters. A missing message may display on the keypad until the transmitter sends a supervision message. Application Example When using an 1139 Bill Trap, program the zone as a Panic type zone. XR500 and XR100 Series panels version 118 or higher provide a Retard Delay that can be programmed on Panic type zones. In System Options set a Retard Delay time from 1 to 250 seconds. This provides time to replace an accidentally removed bill and avoid a false alarm. Also, an output can be assigned to the zone with the action set to Follow. When connected to a preprogrammed DVR and camera, and the panic zone is tripped, the camera can increase the frame speed. Selecting the Proper Location (LED Survey Operation) Note: Refer to Figure 2 to remove the 1139 housing base and Figure 3 for the 1139 PCB LED and tamper switch locations. The 1139 Bill Trap provides a survey capability to allow one person to confirm transmitter communication with the receiver while the cover is removed. The 1139 Bill Trap PCB Red Survey LED turns on whenever data is sent to the receiver then immediately turns off when the receiver acknowledgement is received. Pressing the tamper switch is a convenient way to send data to the receiver to confirm operation. When the tamper switch is pressed or released, the LED blinks once to indicate proper operation. When the transmitter does not receive an acknowledgement from the receiver the LED remains Bill Trap Housing on for about 8 seconds or flashes multiple times in Base Mounting Screw Locations quick succession to let you know communication is not established. Relocate the transmitter or receiver until the LED immediately turns off indicating the transmitter and receiver are communicating properly. Proper communication between the transmitter and receiver is verified when for each press or release of the tamper switch, the LED blinks immediately on and immediately off. Repeat this test to confirm five separate consecutive LED blinks. Any indication otherwise means proper Figure 2: Bill Trap Base and Mounting Screw Locations communication has not been established. Installing the Bill Trap Slide a bill into the Bill Trap on the 1139 as shown in Figure 1. The 1139 Bill Trap unit easily slides into a bill slot of a cash drawer. Place additional bills above the trapped bill for standard cash drawer operation. Installing or Replacing the Battery Observe polarity when installing the battery. Use only 3.0V lithium batteries, DMP Model CR2450, or the equivalent battery from a local retail outlet. Note: When setting up a wireless system, it is recommended to program zones and connect the receiver before installing batteries in the transmitters. Lever Alarm Switch To install or replace batteries or access the tamper switch and view the LED flash: 1. Use a Phillips screwdriver to remove the three screws holding the base and housing together. See Figure 2. 2. Gently lift the PCB out of the housing. 3. If installed, push and slide each old battery out of the holder in the direction of the arrow to remove it. See Figure 3. 4. Verify the positive side of the new battery is up. 5. Slide each new 3.0V lithium battery into its holder and push into place. Red LED Push the Battery Edge to Slide Battery Out Universal Antenna Tamper Switch CR2450 Coin Cell Batteries with Positive Side Up Figure 3: Bill Trap Battery Locations Digital Monitoring Products 1125 PIR Installation Guide 6. Gently slide the PCB back into the housing making sure the lever alarm switch is in position to activate. See Figure 4. Incorrect Lever Alarm Switch Location Correct Lever Alarm Switch Location Red LED Antenna Red LED Antenna Figure 4: Lever Alarm Switch Location Detail 7. Use a Phillips screwdriver to replace the base onto the housing. 8. Slide the bill trap back into the cash drawer. Caution: Properly dispose of unused batteries. Do not recharge, disassemble, heat above 212°F (100°C), or incinerate. Risk of fire, explosion, and burns. Battery Life Expectancy Typical battery life expectancy for DMP Model 1139 Bill Trap is 1 year. DMP wireless equipment uses two-way communication to extend battery life. The following situations can reduce battery life expectancy: • If a receiver is unplugged, too far away, or not installed. Note: Transmitters continue to send supervision messages until a receiver returns an acknowledgement. After an hour the transmitter only attempts a supervision message every 60 minutes. • Frequent transmissions, such as constant removing and replacing the trapped bill. • When installed in extreme hot or cold environments. The following situation can extend battery life expectancy: • Extend transmitter supervision time in panel programming. • Infrequent transmission trips. 1125 PIR Installation Guide Digital Monitoring Products FCC Information This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. It must not be co-located or operated in conjunction with any other antenna or transmitter. Changes or modifications made by the user and not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. Battery Life Expectancy Type See Battery Life Transmit condition Dimensions Color Housing material Compatibility 1 years using 2 batteries 3.0V lithium CR2450 Expectancy for details. Alarm, Tamper 5.375” H x 2.625” W x .625” D Ivory Flame retardant ABS 1100X Wireless Receiver and XR100 or XR500 Series Command Processor™ Panels 1100D Wireless Receiver and XRSuper6, XR20, or XR40 Command Processor™ Panels Patents Patent(s) Pending Listings and Approvals FCC Part 15 Registration ID CCKPC0103 800-641-4282 INTRUSION • FIRE • ACCESS • NETWORKS www.dmp.com 2500 North Partnership Boulevard Made in the USA Springfield, Missouri 65803-8877 LT-0693 (2/07) © 2007 Digital Monitoring Products, Inc. Specifications
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No XMP Toolkit : 3.1-702 Create Date : 2007:02:08 11:01:41Z Modify Date : 2007:02:08 14:42:07-06:00 Metadata Date : 2007:02:08 14:42:07-06:00 Creator Tool : Adobe InDesign 2.0.2 Document ID : adobe:docid:indd:cd064776-b795-11db-ae5f-e388a741c51e Version ID : 1 Rendition Class : proof:pdf Instance ID : uuid:4fc8465b-175b-45dc-bf8e-1c4509e71df6 Rendition Of Document ID : adobe:docid:indd:cd064776-b795-11db-ae5f-e388a741c51e Rendition Of Version ID : 1 Rendition Of Rendition Class : default Contained Resources Document ID : uuid:4b0190ee-283c-410c-bf57-2b07d1fc1672 Format : application/pdf Title : Has XFA : No Page Count : 4 Creator : Adobe InDesign 2.0.2 Producer : Adobe PDF Library 5.0 Trapped : FalseEXIF Metadata provided by EXIF.tools