Digital Monitoring PC0128 Digital Transmission System Transceiver User Manual USERS MANUAL

Digital Monitoring Products Inc Digital Transmission System Transceiver USERS MANUAL

USERS MANUAL

Download: Digital Monitoring PC0128 Digital Transmission System Transceiver User Manual USERS MANUAL
Mirror Download [FCC.gov]Digital Monitoring PC0128 Digital Transmission System Transceiver User Manual USERS MANUAL
Document ID2174667
Application IDGFpSFzopuHZWqPPycz+kDw==
Document DescriptionUSERS MANUAL
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize115.02kB (1437708 bits)
Date Submitted2014-01-23 00:00:00
Date Available2014-01-23 00:00:00
Creation Date2014-01-13 10:27:08
Producing SoftwareAdobe PDF Library 9.9
Document Lastmod2014-01-21 16:04:45
Document TitleUSERS MANUAL
Document CreatorAdobe InDesign CS5.5 (7.5)

Installation Guide
XT Series™ Panels
MODEL XT30/XT50
XT SERIES™
INSTALLATION GUIDE
FCC NOTICE
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant
to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may cause harmful interference
to radio communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the interference by
one or more of the following measures:
•
Reorient or relocate the receiving antenna.
•
Increase the separation between the equipment and receiver.
•
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
•
Consult the dealer or an experienced radio/TV technician for help.
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s
authority to operate the equipment.
This device has been designed to operate with the 1100 Series antenna listed in the Accessory Devices section,
and having a maximum gain of 1.8 dB. Antennas not included in this list or having a gain greater than 1.8 dB are
strictly prohibited for use with this device. The required antenna impedance is 50 ohms.
If necessary, the installer should consult the dealer or an experienced radio/television technician for
additional suggestions. The installer may find the following booklet, prepared by the Federal Communications
Commission, helpful:
“How to identify and Resolve Radio-TV Interference Problems.”
This booklet is available from the U.S. Government Printing Office, Washington D.C.  20402
Stock No. 004-000-00345-4
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)
This device may not cause harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Industry Canada Information
This device complies with Industry Canada Licence-exempt RSS standard(s). Operation is subject to the
following two conditions: (1) this device may not cause interference, and (2) this device must accept any
interference, including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de
licence. L’exploitation est autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas produire de
brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le
brouillage est susceptible d’en compromettre le fonctionnement.
© 2013 Digital Monitoring Products, Inc.
Information furnished by DMP is believed to be accurate and reliable.
This information is subject to change without notice.
Table of Contents
Panel Specifications
1.1
1.2
1.3
1.4
1.5
1.6
1.7
Power Supply..........................................1
Communication........................................1
Panel Zones.............................................1
Keypads/Expansion..................................1
Number of Zones.....................................1
Outputs...................................................1
Enclosure Specifications...........................1
Introduction
2.1
2.2
2.3
System Configurations..............................2
Caution Notes..........................................2
Compliance Instructions...........................2
System Components
3.1
3.2
3.3
3.4
Wiring Diagram........................................2
Lightning Protection.................................2
Accessory Devices....................................2
XT30/XT50 Wiring Diagram......................5
Installation
4.1
4.2
4.3
Mounting the Enclosure............................6
Mounting Keypads...................................7
Installation Specifications.........................7
Primary Power Supply
5.1
5.2
5.3
AC terminals 1 and 2................................7
Transformer Types...................................7
Power LED..............................................7
Secondary Power Supply
6.1
6.2
6.3
6.4
6.5
6.6
6.7
Battery Terminals 3 and 4.........................8
Earth Ground...........................................8
Replacement Period.................................8
Discharge/Recharge.................................8
Battery Supervision..................................8
XT30/XT50 Power Requirements...............8
XT30/XT50 Standby Battery Calculations...9
Bell Output
7.1
Terminals 5 and 6..................................10
Keypad Data Bus
8.1
8.2
8.3
8.4
8.5
8.6
8.7
8.8
8.9
Description............................................10
Terminal 7 - RED...................................10
Terminal 8 - YELLOW.............................10
Terminal 9 - GREEN...............................10
Terminal 10 - BLACK..............................10
Keypad Bus LEDs...................................10
Programming Connection.......................10
Keypad Addressing.................................10
Overcurrent OVC LED.............................11
Smoke and Glassbreak Detector Output
9.1
Terminal 11...........................................11
Burglary Zones
10.1
10.2
10.3
10.4
XT30/XT50 Installation Guide
Description............................................11
Operational Parameters..........................11
Zone Response Time..............................12
Keyswitch Arming Zone..........................12
Digital Monitoring Products
Table of Contents
Powered Zone for 2-Wire Smoke Detectors
11.1
Terminals 25 and 26...............................12
Annunciator Outputs
12.1
12.2
12.3
Description............................................12
Harness Wiring......................................12
Model 860 Relay Module.........................12
Telephone RJ Connector
13.1
13.2
13.3
Description............................................13
FCC Registration....................................13
Notification............................................13
Ethernet Connector J1
14.1
14.2
Description............................................13
Ethernet LEDs.......................................13
Reset Header J16
15.1
Description............................................14
Flash Load Jumper J18
16.1
Description ...........................................15
Cellular Connections
17.1
Cellular ................................................15
On-Board 1100 Series Wireless Antenna Connection
18.1
18.2
Wireless Antenna ..................................16
LED Operation.......................................16
Wireless Keypads
19.1
19.2
Mounting Keypads.................................16
Wireless Keypad Association...................16
Listed Compliance Specifications
20.1
20.2
20.3
20.4
20.5
20.6
20.7
20.8
Introduction..........................................17
Bypass Reports......................................17
Current Draw.........................................17
Battery Standby.....................................17
Auxiliary and Bell Current.......................17
Cross Zoning.........................................17
Software Version....................................17
App Key................................................17
Household Burglar-Alarm System Units
ANSI/UL 1023
21.1
21.2
21.3
21.4
21.5
21.6
21.7
21.8
Bell Cutoff.............................................17
Entry Delay...........................................17
Exit Delay..............................................17
Wireless External Contact.......................17
Wireless Supervision Time......................17
Wireless Audible Annunciation................17
Panel location........................................17
Test Frequency......................................17
Digital Burglar Alarm Communicator System Units
ANSI/UL 1635
22.1
22.2
22.3
22.4
Digital Monitoring Products
ii
Entry Delay...........................................17
Exit Delay..............................................17
Test Frequency......................................17
Automatic Bell Test................................17
XT30/XT50 Installation Guide
Table of Contents
Central Station Burglar Alarm Units
ANSI/UL 1610
23.1
23.2
23.3
Central Station.......................................18
Remote Disarm......................................18
Central Station.......................................18
Household Fire Warning System
ANSI/UL 985 NFPA 72 Specifications
24.1
24.2
24.3
24.4
24.5
24.6
24.7
24.8
24.9
Bell Output Definition.............................18
Household System.................................18
Household Fire Warning.........................18
Wireless Supervision Time......................18
Wireless Fire Verification.........................18
Battery Standby.....................................18
Alarm Verification...................................18
Model 860.............................................18
Test Frequency......................................18
California State Fire Marshal Specifications
25.1
Bell Output Definition.............................18
False Alarm Reduction Programmable Options
ANSI/SIA CP-01-2010
26.1
26.2
26.3
26.4
26.5
Shipping Defaults and
Recommended Programming..................19
Call Waiting...........................................20
Entry Delay...........................................20
Local Bell..............................................20
Minimum Installation Requirements.........20
Troubleshooting
27.1
27.2
Troubleshooting Section.........................21
Common LCD Keypad Displays................21
Wiring Diagrams
28.1
28.2
Multiple Indicating Circuit
Modules Installation...............................22
System Sensor 2-Wire Smoke Detectors..23
Revisions to This Document
Listings and Approvals
XT30/XT50 Installation Guide
Digital Monitoring Products
iii
Panel specifications
Panel Specifications
1.1
Power Supply
Transformer Input:
Plug-in — 16.5 VAC 40 VA, Model 321
Wire-in — 16.5 VAC 40 VA, Model 320
Standby Battery:
12 VDC, 1.0 Amps Max. charging current
Models 364, 365, 366, 368, or 369
Replace every 3 to 5 years
Auxiliary Output:
12 VDC at 500mA
12 VDC at 325mA when used with two Model 364 batteries in the Model 341 enclosure
Bell Output:
12 VDC at 1.5 Amps
Smoke Detector Output:
12 VDC at 100mA
All circuits inherent power limited
1.2
Note: Please see the Listed Compliance Specifications section for certificated application requirements.
Communication
Built-in SDLC Digital Dialer communication to DMP Model SCS-1R Receivers
Built-in network communication to DMP Model SCS-1R or SCS-VR Receivers
Built-in or modular cellular communication to DMP Model SCS-1R or SCS-VR Receivers
Built-in CID (Contact ID) dialer communication to DMP Model SCS-1R Receivers
1.3
Panel Zones
Nine 1k Ohm EOL burglary zones: zones 1 to 9
One 3.3k Ohm EOL Class B powered fire zone with reset capability: zone 10
1.4
Keypads/Expansion
Connect up to eight supervised alphanumeric keypads.
Connect up to four alphanumeric 9000 Series wireless keypads.
Eight keypads total per panel.
Connect additional unsupervised keypads.
• Graphic Touchscreen, Thinline™, Aqualite™, Clear Touch™, and Icon keypads
In addition, the following zone expanders can be added:
• One, four, eight and 16-zone expansion modules
• Single-zone PIR and glassbreak detectors
1.5
Number of Zones
•
•
•
•
1.6
Onboard zones 1-10
Eight keypad bus addresses with zones 11-14, 21-24, 31-34, 41-44, 51-54, 61-64, 71-74, and 81-84
Zone numbers 31 to 34 and 41 to 44 can support 1100 Series Key Fobs or DMP wireless output modules
XT50 has 20 additional onboard wireless zones numbered 80-99
Outputs
The XT30/XT50 panels provide four open collector outputs rated for 50mA each. A Model 300 Output Harness
is required. The open collector outputs provide the ground connection for a positive voltage source.
1.7
Enclosure Specifications
The XT30/XT50 panel ships standard in a 340 enclosure with EOL resistors, battery leads, user’s guide, and
programming sheet.
Enclosure Model
Size
Color
Construction (Cold Rolled Steel)
340
12.5” W x 9.5” H x 2.75” D
Gray (G)
20-Gauge
349
12.5” W x 11.5” H x 3.5” D
Gray (G)
20-Gauge
349A
13.25” W x 11.65” H x 3.6” D
Gray (G)
18-Gauge with 16-Gauge door
341
13” W x 6.55” H x 3.5” D
Gray (G)
20-Gauge
XT30/XT50 Installation Guide
Digital Monitoring Products
Introduction
Introduction
2.1
System Configurations
The panel can be programmed to operate as any of the following system types:
• All/Perimeter system that provides one perimeter area and one interior area
• Home/Sleep/Away system that provides one perimeter, one interior, and one bedroom area. The
bedroom area provides for any protection devices the user wants disarmed during their sleeping hours
and armed in the Away mode.
• Six area system that provides areas of protection that can be independently armed or disarmed.
2.2
Caution Notes
Throughout this guide you will see caution notes containing information you need to know when installing
the panel. These cautions are indicated with a yield sign. Whenever you see a caution note, make sure you
completely read and understand its information. Failing to follow the caution note can cause damage to the
equipment or improper operation of one or more components in the system. See the example shown below.
Always ground the panel before applying power to any devices: The panel must be properly grounded
before connecting any devices or applying power to the panel. Proper grounding protects against
Electrostatic Discharge (ESD) that can damage system components.
Remove All Power From the Panel! Remove all AC and Battery power from the panel before installing or
connecting any modules, cards, or wires to the panel.
2.3
Compliance Instructions
For applications that must conform to a local authorities installation standard or a National Recognized Testing
Laboratory certificated system, please see the Listed Compliance Specifications section near the end of this
guide for additional instructions.
System Components
3.1
Wiring Diagram
The system wiring diagram in Figure 1 shows some of the accessory devices for use in various applications. A
description of each module follows.
3.2
Lightning Protection
Metal Oxide Varistors and Transient Voltage Suppressors help protect against voltage surges on input and
output circuits. This transient protection provides additional resistance to electrical surges such as lighting.
Additional surge protection is available by installing the DMP 370 or 370RJ Lightning Suppressors.
Digital Monitoring Products
XT30/XT50 Installation Guide
system components
3.3
Accessory Devices
Cellular Communicator Cards
263G Digital Cellular
Communicator Card
Allows you to connect the XT30/XT50 Series to any compatible GPRS/SMS network and use
its communication in place of standard dial out lines.
263C CDMA Cellular Communicator Allows you to connect the XT30/XT50 Series to any compatible CDMA/SMS network.
Card
263H HSPA + Cellular
Communicator Card
Allows you to connect the XT30/XT50 Series to any compatible HSPA+/SMS network.
The 263H is compatible with XT30 and XT50 Series control panels, version 112 or higher
Zone and Output Expansion Modules
710 Bus Splitter/Repeater
Increases keypad wiring distance to 2500 feet.
711 Single Point Zone Expander
Provides one Class B zone for burglary devices and non-powered fire devices.
714, 714-8, 714-16 Zone Expander
Provides Class B zones for burglary and non-powered fire devices.
712-8 Zone Expander
Provides 8 zones for burglary devices.
715, 715-8, 715-16 Zone
Expander
Provides 12 VDC Class B powered zones for smoke detectors, glassbreak detectors, and
other 2- or 4-wire devices.
860 Relay Output Module
Provides one relay and three relay sockets for expansion of up to four relays.
Interface Module
734 Wiegand Interface Module
Provides arming, disarming, and codeless entry using access control readers.
738Z Z-Wave Interface Module
Provides connection for Z-Wave modules.
DMP Two-Way Wireless Devices
1100D/1100DH/1100DI Receiver
Supports transmitters in residential or commercial wireless operation on the keypad bus.
1100R Repeater
Provides additional range for wireless devices.
1101 Universal Transmitter
Provides both internal and external contacts that may be used at the same time to yield two
individual reporting zones from one wireless transmitter.
1102 Universal Transmitter
Provides one external contact.
1103 Universal Transmitter
Provides both and internal and external contacts that may be used at the same time to
yield two individual reporting zones from one wireless transmitter. Requires EOL resistor for
external contact.
1105 Universal Transmitter
Provides both internal and external contacts that may be used at the same time to yield two
individual reporting zones from one wireless transmitter.
*1107 Micro Window Transmitter
Provides a window transmitter and magnet
*1114 Four-Zone Expander
Provides four wireless zones with EOL resisters.
*1116 Relay Output
Provides one Form C relay.
*1117 LED Annunciator
Provides a visual system status indicator.
*1119 Door Sounder
Provides a battery operated sounder
*1121 PIR Motion Detector
Provides motion detection with pet immunity.
1125 PIR Motion Detector
Provides multiple lens configurations, dual coverage area selection, and sensitivity
adjustments.
*1126C/*1126R PIR Motion
Detector
Ceiling mount motion detector with panel programmable sensitivity and Disarm/Disable
functionality.
1127C/1127W PIR Motion
Detector
Wall mount motion detector with panel programmable sensitivity and Disarm/Disable
functionality.
*1129 Glassbreak Detector
Detects the shattering of framed glass mounted in an outside wall and provides full-pattern
coverage and false-alarm immunity.
*1131 Recessed Contact
Provides concealed protection for doors, windows or other applications.
1135/*1135DB Sirens
Provides a wireless siren
*1139 Bill Trap
Provides a silent alarm option for retail and banking cash drawers.
1142BC Two-button Panic Belt
Clip Transmitter
Provides portable two-button panic operation.
1142 Two-button Panic Transmitter Provides permanently mounted under-the-counter two-button panic operation.
XT30/XT50 Installation Guide
Digital Monitoring Products
system components
*1145-4 (Four-Button)
*1145-2 (Two-Button)
*1145-1 (One-Button)
Key Fob transmitters designed to clip onto a key ring or lanyard.
1161 Residential Smoke Detector
Residential smoke detector with sounder.
1162 Residential Smoke Detector
Residential smoke/heat detector with sounder and fixed rate-of-rise heat detector
1183-135F Heat Detector
Fixed temperature heat detector
1183-135R Heat Detector
Fixed temperature and rate-of-rise heat detector
1184 Carbon Monoxide Detector
Carbon Monoxide Detector.
Keypads
*ePAD™ Mobile Keypad
Allows users to control the security system from any computer using the Internet.
LCD keypads
Allows you to control the panel from various remote locations. Connect up to eight keypads.
Model 7060, 7063, 7070, 7073, 7160, 7163, 7170, 7173 Thinline™ keypads, 7060A, 7063A,
7070A, 7073A Aqualite™ keypads, 7360, 7363 Thinline Icon Series keypads, 7760 Clear Touch™
keypad, 7872 and 7873 Graphic Touchscreen keypads to the keypad bus using terminals 7, 8,
9, and 10.
9000 Series LCD keypads
Allows you to control the panel from various remote locations. Connect up to four keypads.
9060, 9063 Wireless Keypads.
* These devices have not been investigated and shall not be used in listed installations
Digital Monitoring Products
XT30/XT50 Installation Guide
Installation
3.4
XT30/XT50 Wiring Diagram
NFPA 72
USE MARKING
Commercial Central Station; Household Fire and This equipment should be installed in accordance with Chapter 11
of the National Fire Alarm Code, ANSI/NFPA 72-2002, (National
Burglar Warning System Control Unit (DACT,
Fire Protection Association, Batterymarch Park, Quincy, MA
PSDN: IP or Cellular)
02269). Printed information describing proper installation,
TYPES OF SERVICE
operation, testing, maintenance, evacuation planning, and repair
Suitable for DACT Central Station.
service is to be provided with this equipment. Warning: Owner’s
Suitable for Household Fire and
instruction notice, not to be removed by anyone except occupant.
Household Burglary. Test weekly.
SIA CP-01-2010 minimum system is
XT30 or XT50, local Bell, and off
XT30/XT50
premise DACT communication to an
Command Processor™ Panel
SCS-1R receiver plus ANSI/SIA
Plug into
120 VAC
60 Hz
outlet not
controlled
by switch.
s s
16 to 18
gauge wire
J11
J1
Ethernet
J3
Phone Line
Model 321 – 16.5 VAC 40 VA
Class 2 plug-in.
Model 320 – 16.5 VAC 40 VA
Class 2 wire-in.
RED
Programmer Header J8
Use DMP Model 330 Harness
Outputs
J8
Bell
Keypad
Bus
PROG
Smoke
Detector
RED
BLACK
Smoke
Switched
Voltage
Output
Zones 1 to 9
1K Ohm EOL
on each zone
To Keypad
or Zone
Expander
Zone 10 compatibility
identifier: A
Maximum operating
range:
8.8 VDC - 14.2 VDC.
Minimum voltage on
Auxiliary output to
process Sensor trips
is 10.4 VDC.
J16
Reset
Terminals 5-20 are Power Limited.
Maximum AC
Wire distance –
16 gauge wire: 70 feet
18 gauge wire: 40 feet
Bell — 10.2 - 13.9 VDC
Total current: 1.5 Amps max.
w/ 40 VA.
AUX (RED) — Up to 500mA
auxiliary current at 10.2 VDC 13.9 VDC from Terminal 7.
Up to 325mA auxiliary current
at 10.2 VDC - 13.9 VDC from
Termical 7 when using (2)
Model 364 1.3Ah Batteries.
Smoke Output: — 100mA at
10.2 - 13.9 VDC Terminal 11.
J20
Wireless
Antenna
connection
263
Module
J7 RJ
Supervision
DMP Transformers
Wiring on terminals 5 through 26
must exit right and maintain a 1/4"
separation from the AC and battery
positive wiring.
POWER LIMITED
All circuits on the Model XT30/XT50 comply
with the requirements for inherent power
limitation and are Class 2.
65555
CP-01-2010 classified compatible DMP
keypads as indicated in the installation
guide.
AC Wiring must be in conduit and exit
out the left side of the enclosure.
HOUSEHOLD FIRE WIRING
Recognized limited energy cable must be
used for connection of all initiating,
indicating, and supplementary devices.
Listed Resistors
1.0k Ohm - DMP Model 311
3.3k Ohm - DMP Model 309
Zone 10
3.3K Ohm EOL
Heat detectors, manual pull stations, or any
other shorting device. Unlimited number of
units.
Verification Control Unit
Zone
Delay
10
13.6 sec.
Smoke
Model
______
Detector
Delay
____sec.
For Wireless Devices, Control Unit delay is 0 (zero).
Secondary Power Supply
1.2 Amps maximum charging current. Use only
12 VDC rechargeable batteries. Replace every 3
to 5 years.
Earth Ground
1k Ohm
For listed applications the maximum current from a combination of bell
output, auxillary output, and smoke output is 1.6 amps.
Figure 1: System Wiring Diagram
XT30/XT50 Installation Guide
Digital Monitoring Products
Installation
Installation
4.1
Mounting the Enclosure
The metal enclosure must be mounted in a secure, dry place to protect the panel from damage due to
tampering or the elements. It is not necessary to remove the PCB when installing the enclosure. The PCB
may be installed in the standard 340 Small enclosure, optional 341 Kiosk enclosure, optional 349 Medium
enclosure, or the optional 349A Attack enclosure.
When using cellular communication or on-board wireless with the 341 enclosure, an SMA and wireless
antenna exit may be added at the time of the installation. The 349A Attack Resistant enclosure is factory
shipped with one knockout on the top left of the enclosure. As needed, additional knockouts may be
added at the time of installation. See Figure 3 for the positions on the enclosure that can be added. Each
additional knockout must be filled with conduit.
Slide panel PCB into lower enclosure slots
Model 349 Enclosure
Enclosure
Mounting
Hole
Slide panel PCB between formed metal supports
Model 340 Enclosure
J20
Wireless
Antenna
connection
J18
263
Module
J7 RJ
Supervision
Enclosure
Mounting
Hole
Load
Panel
PCB
screw
J11
Enclosure
Mounting
Hole
J16
Reset
Panel
PCB
screw
Panel
PCB
screw
Programming
J1
Ethernet
J8
J16
Reset
J8
RED
12
34
Outputs
Programming
12
34
J1
Ethernet
J11
J18
Load
RED
Outputs
J3
Phone
Line
263
Module
J3
Phone
Line
65555
J20
Wireless
Antenna
connection
65555
J7 RJ
Supervision
Panel
PCB
screw
Dual 1/2" and 3/4" Conduit Knockout
Dual 1/2" and 3/4" Conduit Knockouts
Enclosure Mounting Holes
Enclosure Mounting Holes
Battery Shelf
Battery Shelf
Figure 2: Standard 340 Enclosure (left), Optional 349 Enclosure (right)
Slide panel PCB between formed metal supports
Model 349A Enclosure
Model 341 Enclosure
Openings drilled
at installation
PEMs for optional battery bracket
Lid Mounting Holes (4 places)
J3
Phone
Line
J20
Wireless
Antenna
connection
(XT50 only)
65555
263
Module
J7 RJ
Supervision
TX RX
Wireless LEDs
J18
Load
J1
Ethernet
J3
Phone Line
J11
J18
Load
J1
Ethernet
J16
Reset
J8
3-Hole
Pattern for
Accessory
Modules
Programming
J11
Outputs
RCV
J16
Reset
J8
XMIT
Dual 1 3/4" and 1 3/8" Conduit Knockouts
Programming
* 349A Optional Knockout
Dual 1/2" and 3/4" Conduit Knockouts
Tamper Mounting Holes
(Upper and Lower)
12
34
Outputs
RED
OVC LED
Power
LED
263
Module
J7 RJ
Supervision
Lid Mounting Holes
(4 places)
J20
Wireless
Antenna
connection
65555
Enclosure Mounting Holes (4 places)
Front and
Rear Tamper
Switches for
350A Attack
Resistant
Enclosure
Battery Shelf
Figure 3: Optional 341 Enclosure (left), Optional 349A Enclosure (right)
Digital Monitoring Products
XT30/XT50 Installation Guide
Installation
4.2
Mounting Keypads
DMP keypads have removable covers that allow the base to be mounted on a wall or other flat surface using
the screw holes provided on each corner.
For mounting keypads on solid walls, or for applications where conduit is required, use a DMP 695 or 696
keypad conduit backbox.
4.3
Installation Specifications
Several factors determine the performance characteristics of the keypad bus: the length of wire used, the
number of devices connected, and the voltage at each device. When planning a keypad bus installation,
keep in mind the following four specifications:
1. DMP recommends using 18 or 22-gauge unshielded wire for all keypad circuits. Do not use twisted pair
or shielded wire for keypad bus data circuits.
2. On keypad bus circuits, to maintain auxiliary power integrity when using 22-gauge wire do not exceed
500 feet. When using 18-gauge wire do not exceed 1,000 feet. To increase the wire length or to add
devices, install an additional power supply.
Note: Each panel allows a specific number of supervised keypads. Add additional keypads in the
unsupervised mode. Refer to the panel installation guide for the specific number of supervised keypads
allowed.
3. Maximum distance for any one bus circuit (length of wire) is 2,500 feet regardless of the wire gauge.
This distance can be in the form of one long wire run or multiple branches with all wiring totaling no
more than 2,500 feet. As wire distance from the panel increases, DC voltage on the wire decreases.
4. Maximum voltage drop between the panel (or auxiliary power supply) and any device is 2.0 VDC. If the
voltage at any device is less than the required level, add an auxiliary power supply at the end of the
circuit. When voltage is too low, the devices cannot operate properly.
For additional information refer to the 710 Installation Sheet (LT-0310) and or the LX-Bus/Keypad Bus Wiring
Application Note (LT-2031).
Primary Power Supply
5.1
AC terminals 1 and 2
Connect the transformer wires to terminals 1 and 2 on the panel. Use no more than 70 ft. of 16 gauge, or
40 ft. of 18 gauge, wire between the transformer and the panel to deliver a minimum of 15.5 VAC when
500mA of current draw is used from the auxiliary power supply terminal 7.
Always ground the panel before applying power to any devices: The panel must be properly grounded
before connecting any devices or applying power to the panel. Proper grounding protects against
Electrostatic Discharge (ESD) that can damage system components. See Earth ground, in the Secondary
Power Supply section.
5.2
Transformer Types
The transformer for the panel is 16.5 VAC 40 VA, which provides up to 1.5 Amps of bell output current,
500mA of auxiliary current, and 100mA of smoke detector output. Use either the Model 320 wire-in or
321 plug-in transformer with the panel. The total current available is limited by the total battery standby
requirements of the installation.
The transformer must be connected to a 120 VAC 60 Hz commercial power outlet that is not con­trolled by a
wall switch. Never share the transformer output with any other equipment.
5.3
Power LED
When either AC transformer power or DC battery power is connected to the panel the PWR LED shows steady
green.
XT30/XT50 Installation Guide
Digital Monitoring Products
Installation
Secondary Power Supply
6.1
Battery Terminals 3 and 4
Connect the black battery lead to the
negative battery terminal. The negative
terminal connects to the enclosure
ground internally through the XT30 or
XT50 circuit board. Connect the red
battery lead to the positive battery
terminal. Observe polarity when
connecting the battery.
Add a second battery in parallel
using the DMP Model 318 Dual Battery
Harness. DMP requires each battery
be separated by a PTC in the battery
harness wiring to protect each battery
from a reversal or short within the
circuit. See Figure 4.
XT30/XT50
Command Processor
Panel
AC AC +B –B BELL GND
To AC
Red
318 Battery
Harness
Red
Black
PTC
Panel Red and
Black Battery Cables
14 AWG to
Earth Ground
To Bell
Circuit
Black
Battery
Battery
Figure 4: Wiring Multiple Batteries
Use sealed lead-acid batteries only: Use 12 VDC sealed lead-acid rechargeable battery. Batteries supplied
by DMP have been tested to ensure proper charging with DMP products.
GEL CELL BATTERIES CANNOT BE USED WITH THE XT30/XT50 PANEL.
6.2
Earth Ground
Terminal 4 of the panel must be connected to earth ground using 14 gauge or larger wire to provide proper
transient suppression. DMP recommends connecting to a metal cold water pipe or ground rod only. Do not
connect to electrical conduit or a telephone company ground.
6.3
Replacement Period
DMP recommends replacing the battery every 3 to 5 years under normal use.
6.4
Discharge/Recharge
The panel battery charging circuit float charges at 13.9 VDC at a maximum current of 1.2 Amps using a 40 VA
transformer. The total current available is reduced by the combined auxiliary current draw from terminals 7,
11, and 25. The various battery voltage levels are listed below:
Battery Trouble:
Battery Restored:
6.5
Below 11.9 VDC
Above 12.6 VDC
Battery Supervision
The panel tests the battery once every hour when AC power is present. This test occurs 15 minutes past
each hour and lasts for five seconds. A load is placed on the battery and if its voltage falls below 11.9 VDC a
low battery is detected. If AC power has failed, a low battery is detected any time the battery voltage falls
below 11.9 VDC.
If a low battery is detected with AC power present, the test is repeated every two minutes until the battery
charges above 12.6 VDC; the battery restored voltage. If a faulty battery is replaced with a fully charged
battery, the restored battery will not be detected until the next two-minute test is done.
6.6
XT30/XT50 Power Requirements
During AC power failure, the panel and all auxiliary devices connected draw their power from the battery.
All devices must be taken into consideration when calculating the battery standby capacity. On the following
page is a list of the power requirements of the panel. Add the additional current draw of DMP keypads,
smoke detector output, and any other auxiliary devices used in the system for the total current required.
The total is then multiplied by the total number of standby hours required to arrive at the total Amperehours required.
Digital Monitoring Products
XT30/XT50 Installation Guide
Installation
6.7
XT30/XT50 Standby Battery Calculations
Standby Battery Power Calculations
Alarm Current
XT30 Panel
XT50 Panel
Built-in Network (additional current)
Built-in Cellular (additional current)
Active Zones 1-9
Active Zone 10
2-Wire Smoke Detectors
Panel Bell Output
x 125mA ______mA
x 145mA ______
x 145mA ______
x 18mA ______
x 1.6mA ______
4mA ______
0.1mA ______
263G Digital Cellular Communicator
263C Digital Cellular Communicator
263H HSPA+ Cellular Communicator
125mA
145mA
145mA
18mA
*2mA
30mA
0.1mA
Max.
______mA
______
______
______
______
______
______
______
Qty ______
Qty ______
Qty ______
1500mA
18mA ______
Qty ______
18mA ______
13mA ______
Qty ______
13mA ______
24mA ______
Qty ______
28mA ______
1100D Wireless Receiver
40mA ______
Qty ______
40mA ______
1100DH Wireless High Power Receiver
x 160mA ______
Qty ______
1100DI Wireless In-Line Receiver
30mA ______
Qty ______
860 Relay Output Module (one relay active)
All four relays active
34mA ______
138mA ______
Qty _______
34mA ______
138mA ______
7060/7160 Thinline/7060A Aqualite
7063/7163 Thinline/7063A Aqualite
7070/7170 Thinline/7070A Aqualite
Active Zones (EOL Installed)
7073/7173 Thinline/7073A Aqualite
Active Zones (EOL Installed)
7360 Thinline Icon Keypad
7363 Thinline Icon Keypad
Keypad
Keypad
Keypad
Qty
Qty
Qty
Qty
______
______
______
______
87mA
100mA
67mA
80mA
Keypad
72mA
85mA
72mA
1.6mA
85mA
1.6mA
60mA
73mA
Qty ______
Qty ______
67mA ______
80mA ______
______
______
______
______
______
______
______
______
160mA ______
30mA ______
______
______
______
______
7872 Graphic Touchscreen Keypad
Active Zones (EOL Installed)
x 145mA ______
1.6mA ______
Qty ______
215mA ______
2.0mA ______
7873 Graphic Touchscreen Keypad
Active Zones (EOL Installed)
x 143mA ______
1.6mA ______
Qty ______
243mA ______
2.0mA ______
708 Bus Extender Module (one pair)
Qty ______
20mA ______
710 Bus Splitter/Repeater Module
714 Zone Expansion Modules
Active Zones (EOL Installed)
712-8 Zone Expansion Module
Active Zones (EOL Installed)
714-8, 714-16 Zone Expansion Module
Active Zones (EOL Installed)
715 Zone Expansion Module
Active Zones (EOL Installed)
2-Wire Smokes
715-8, 715-16 Zone Expansion Modules
Active Zones (EOL Installed)
2-Wire Smokes
734 Wiegand Interface Module
Active Zones (EOL Installed)
738A Ademco Wireless Interface Module
738Z Z-Wave Interface Module
Aux. Powered Devices on Terminals 7 and 11
Other than Keypads and Modules
Qty
Qty
Qty
Qty
Qty
Qty
Qty
Qty
Qty
Qty
Qty
______
______
______
______
______
______
______
______
______
______
______
Qty
Qty
Qty
Qty
______
______
______
______
20mA ______
30mA
7mA
1.6mA
17mA
1.6mA
20mA
1.6mA
7mA
4mA
.1mA
20mA
4mA
.1mA
15mA
1.6mA
75mA
32mA
______
______
______
______
______
______
______
______
______
______
______
______
______
______
______
______
______
______mA
Total Standby ______mA
Total Standby______mA x number of Standby Hours ______ =
needed ______mA
Total Alarm
Total
* Based on 10% of active zones in alarm condition.
XT30/XT50 Installation Guide
30mA
7mA
*2mA
17mA
*2mA
20mA
*2mA
7mA
*30mA
.1mA
20mA
*30mA
.1mA
15mA
*2mA
75mA
47mA
______
______
______
______
______
______
______
______
______
______
______
______
______
______
______
______
______
______mA
Total Alarm ______mA
________mA-hours
________mA-hours
________mA-hours
X .001
= ________Amp-hrs
Required
Digital Monitoring Products
Installation
Bell Output
7.1
Terminals 5 and 6
Nominal 12 VDC is supplied by terminal 5 on the panel to power alarm bells or horns. The output is rated
for a maximum of 1.5 Amps with a 40 VA transformer. This output can be steady, pulsed, or Temporal Code 3
depending upon the Bell Action specified in Output Options programming. Terminal 6 is the ground reference
for the bell circuit. If using a horn or siren, a 1k 0hm resister should be added across the bell circuit for
supervision.
Keypad Data Bus
8.1
Description
Terminals 7, 8, 9, and 10 of the panel are designated as the keypad data bus. In addition to keypads, the
XT30/XT50 allows the connection of any combination of zone expansion modules, Glassbreak Detectors, and
PIRs to the keypad bus up to the maximum of eight devices.
8.2
Terminal 7 - RED
Nominal 12 VDC is supplied at terminal 7 to power keypads and zone expanders. This is also where power
for any auxiliary device is supplied. The ground reference for terminal 7 is terminal 10. The maximum output
is rated at 500mA. All auxiliary devices totaled together must not exceed the Terminal 7 maximum current
rating of 500mA. When the number of keypads or other expansion devices attached exceeds the amount of
output current available, attach an external power supply as defined in the Model 710 Installation Sheet
(LT-0310).
8.3
Terminal 8 - YELLOW
Data receive from keypads and zone expanders.
8.4
Terminal 9 - GREEN
Data transmit to keypads and zone expanders.
8.5
Terminal 10 - BLACK
Terminal 10 is the ground reference for LCD keypads, zone expanders, and any auxiliary devices being
powered by terminals 7 and 11.
8.6
Keypad Bus LEDs
The two LEDs located just above terminal 13 indicate keypad transmit data (XMIT) and keypad receive data
(RCV). The bottom LED flashes green to indicate data being transmitted from the panel. The top LED flashes
yellow to indicate data being received by the panel from keypads, zone expanders, etc.
8.7
Programming Connection
A locking 4-pin header (J8) is provided to connect a keypad when using a DMP Model 330 Programming Cable.
This provides a quick and easy connection for programming the panel.
8.8
Keypad Addressing
Keypad Bus expansion zones are numbered in groups of four corresponding to the address. Example: address
1 is zones 11-14 and address 5 is zones 51-54. There are a maximum of 32 zones possible on the Keypad Bus.
All keypad zones terminate with a 1k 0hm EOL resister.
Address
Digital Monitoring Products
10
XT30/XT50
Zone Number
11-14
21-24
31-34
41-44
51-54
61-64
71-74
81-84
XT30/XT50 Installation Guide
Installation
8.9
Overcurrent OVC LED
The Overcurrent LED (OVC) lights Red when the devices
connected to the Keypad Bus draw more current than the
auxiliary output rating. The OVC LED is located above
terminals 9 and 10 as shown in Figure 4. When the OVC LED
lights Red, the Keypad bus/auxiliary power (terminal 7) and
the Programming header (J8) shut down.
J7 RJ
Supervision
J3
Phone Line
Smoke and Glassbreak Detector Output
9.1
OVC LED
Power
LED
Terminal 11
Nominal 12 VDC at 100mA maximum (shared by terminal 25)
is supplied at terminal 11 to power 4-wire smoke detectors or
other auxiliary powered devices. This output can be turned
off by the user for 5 seconds using the Sensor Reset option
in the User Menu. Terminal 10 is the ground reference for
terminal 11.
Figure 5: OVC LED location
Burglary Zones
10.1 Description
On XT30/XT50 panels, terminals 12 to 24 are the nine burglary zones. For programming purposes, the zone
numbers are 1 to 9. The zone configurations on terminals 12 to 24 are described below.
Terminal Function
Terminal
Function
12
Zone 1 voltage sensing
19
Ground for zones 5 & 6
13
Ground for zones 1 & 2
20
Zone 6 voltage sensing
14
Zone 2 voltage sensing
21
Zone 7 voltage sensing
15
Zone 3 voltage sensing
22
Ground for zones 7, 8, & 9
16
Ground for zones 3 & 4
23
Zone 8 voltage sensing
17
Zone 4 voltage sensing
24
Zone 9 voltage sensing
18
Zone 5 voltage sensing
The voltage sensing terminal measures the voltage across the 1k Ohm End-of-Line resistor and the zone’s
ground terminal. Dry contact sensing devices can be used in series (normally-closed) or in parallel (normallyopen) with any of the burglary protection zones.
10.2 Operational Parameters
Each burglary protection zone detects three conditions: open, normal, and short.
The parameters for each are listed below:
		Condition
Open
Normal
Short
Resistance on zone
over 1300 ohms
600 to 1300 ohms
under 600 ohms
1K Ohm
Normally
Closed
Voltage on zone terminal
over 2.0 VDC
1.2 to 2.0 VDC
under 1.2 VDC
1K Ohm
Normally Open
1K Ohm
Combination Normally Open
and Normally Closed
Figure 6: Protection Zone Contact Wiring
XT30/XT50 Installation Guide
Digital Monitoring Products
11
Installation
10.3 Zone Response Time
A condition must be present on a zone for 500 milliseconds before it is detected by the panel. Ensure
detection devices used on the protec­tion zones are rated for use with this delay.
10.4 Keyswitch Arming Zone
You can use a momentary keyswitch on a zone programmed as an Arming type for use in arming and
disarming the system without a code.
Powered Zone for 2-Wire Smoke Detectors
11.1 Terminals 25 and 26
A resettable 2-wire Class B powered zone is provided on terminals 25 (positive) and 26 (negative) of the
panel. For programming purposes, the zone number is 10 on the XT30/XT50. The zone uses a Model 309, 3.3k
Ohm EOL resistor (provided with the panel) and has an operating range of 8.8 to 13.9 VDC.
The compatibility identifier is: B
Caution: Sensor reset on zone 10 drops power to devices on this zone, causing the panel to sense an open
condition on all zone types other than Fire, Fire Verify, and Supervisory. Whenever non-Fire and nonSupervisory zone types are used on zone 10, make the appropriate adjustments to the zone’s Armed Action
to prevent false alarms from occurring.
Manufacturer
Model
Detector
ID
# of
Detectors
Zone Expansion Modules
DMP/Hochiki
SLR-835B
HD-6
715, 715-8, 715-16, 725
Sentrol/ESL
429AT, 521B, 521BXT
S09A
12
715, 715-8, 715-16
System Sensor
2WTA-B, 2WTR-B
10
715, 715-8, 715-16
Annunciator Outputs
12.1 Description
The four annunciator outputs can be programmed to indicate the activity of the panel’s zones or conditions
occurring on the system. Annunciator outputs do not provide a voltage but instead switch-to-ground voltage
from another source. The outputs can respond to any of the conditions listed below:
1)
2)
3)
4)
5)
Activation by zone condition: Steady, Pulse, Momentary, or Follower
Manually from the keypad
Communication failure
Armed area annunciation
Fire Alarm or Fire Trouble
6)
7)
8)
9)
Ambush alarm
Exit and Entry timers
System Ready
Late to Close
12.2 Harness Wiring
The open collector outputs are accessible by installing the DMP 300 Harness on the 4-pin header labeled J11.
The output locations are shown below. For listed applications, devices connected to outputs must be located
within the same room as the panel.
Output Color
Red
Yellow
Wire
Output
Color Wire
Green 3
Black
12.3 Model 860 Relay Module
Connect a Model 860 Relay Module to the panel to provide relays for the annunciator outputs that can be
used for electrical isolation between the alarm panel and other systems or for switching voltage to control
various functions. The module includes one relay and provides three additional sockets for expansion of up
to four relays. Power is supplied to the relay coils from the panel keypad bus. The 860 mounts inside the
panel enclosure using the 3-hole mounting configuration. Plastic standoffs are provided with the module for
ease of installation. A 4-wire harness is also provided that connects the Model 860 to the panel.
Relay Contact Rating: 1 Amp at 30 VDC
Digital Monitoring Products
12
XT30/XT50 Installation Guide
Installation
Telephone RJ Connector
13.1 Description
Connect the panel to the public telephone network by installing a DMP 356 RJ Cable between the panel’s J3
connector and the RJ31X or RJ38X phone jack. CAUTION - To reduce the risk of fire, use only No. 26 AWG or
larger telecommunication line cord, such as DMP Model 356 Series Phone Cords.
A two pin header labeled RJ SUP (J7) is provided to allow monitoring of the telephone cable connected
between the panel and a RJ38X jack (pins 2 and 7 jumpered). Attach a DMP Model 306 Harness between J7
and any available zone. The J7 pins are connected via the telephone cable to the RJ38X jack pins 2 and 7.
The RJ38X jack provides a jumper between pins 2 and 7 which completes the circuit. Program the zone as a
Supervisory type (SV). When the telephone cable is removed, the keypad displays zone trouble and produces
a steady tone.
To Telephone
Line
Ring
Tip
To Premise
Phone(s)
Ring 1
RJ31X or RJ38X
Phone Block
Tip 1
Figure 7: Phone Jack Wiring
13.2 FCC Registration
The panel complies with FCC part 68 and is registered with the FCC.
Registration number: CCKAL00BXT50
Ringer Equivalence: 0.0B
13.3 Notification
Registered terminal equipment must not be repaired by the user. In case of trouble, the device must be
immediately unplugged from the telephone jack. The factory warranty provides for repairs. Registered
terminal equipment may not be used on party lines or in connection with coin telephones. No­tification must
be given to the telephone company with the following information:
a.  The particular line(s) the service is connected to
b. The FCC registration number
c. The ringer equivalence
d.  The make, model, and serial number of the device
Ethernet Connector J1
14.1 Description
The Ethernet Connector (J1) is available on the Network version and connects directly to an Ethernet
network using a standard patch cable.
14.2 Ethernet LEDs
The two LEDs, located on the left side of the J1 Ethernet Connector, indicate network operation. The top,
Link LED is a steady green light when an ethernet cable is connected. The bottom, Activity LED flashes
yellow to indicate messages are being received or transmitted.
XT30/XT50 Installation Guide
Digital Monitoring Products
13
Installation
Reset Header J16
15.1 Description
The reset header is located just above the terminal strip on the right side of the circuit board and is used
to reset the XT30/XT50 microprocessor. To reset the panel when first installing the system, install the reset
jumper before applying power to the panel. After connecting the AC and battery, remove the reset jumper.
To reset the panel while the system is operational, for example, prior to reprogramming, install the reset
jumper without powering down the system. Remove the reset jumper after one or two seconds.
After resetting the panel, begin programming within 30 minutes. If you wait longer than 30 minutes, reset
the panel again.
XT30/XT50 Panel
TX RX
Wireless LEDs
J7 RJ
Supervision
J3
Phone Line
J18
Load
J1
Ethernet
J11
Outputs
OVC LED
Power
LED
J20
Wireless
Antenna
connection
J24 Celllular
header
RCV
J8
XMIT
Programming
Momentarily
place the Reset
jumper over both
of the J16 pins to
reset the panel.
J16
Reset
Figure 8: Panel Showing the Reset Header
Digital Monitoring Products
14
XT30/XT50 Installation Guide
Installation
16.1 Description
Flash Load Jumper J18
The XT Series panel software can be updated via the panel’s programming (PROG) header. To update the
panel with a new software version, complete the following steps at the protected premise:
1. Place a jumper across the Reset (J16) header and then remove the yellow and green wires from keypad
bus terminals 8 and 9.
2. Connect a DMP 399 Cable from the J8 Programming Header to the serial port of your PC operating
Remote Link and containing the XT RU file. Requires Remote Link 1.43 or higher.
3. Start Remote Link and create or open the XT Series control panel account that matches the panel to be updated.
4. Set the Connection Information Type to Direct with a baud rate of 38400 and choose the appropriate COM port.
5. Select Panel>Remote Update, then select the correct RU file for the XT panel model.
6. While placing a short across the LOAD (J18) header, remove the jumper from the Reset (J16) header.
Click  in Remote Link.
7. After the software version is updated, remove the short from the LOAD header. Place the jumper across
Reset (J16) then remove the 399 cable.
8. Replace the yellow and green wires to terminals 8 and 9.
9. Remove Reset (J16) jumper to resume normal panel operation.
Cellular Connections
17.1 Cellular
The J24 header is provided to connect a 263G Digital Cellular Communicator, 263C CDMA Cellular
Communicator, or 263H HSPA+ Cellular Communicator. The cellular antenna connection protrudes through
the top of the enclosure.
Brass
Washer
1100 Series
Antenna
(XT50)
To J24 Celllular
header
J20
1100 Series
Wireless Antenna
connection
Wireless LEDs
65555
Connect
antenna to
right side
only
TX RX
J18
Load
Outputs
J1
Ethernet
RCV
J11
263 Module
J8
J16
Reset
XMIT
Programming
Figure 9: Cellular and 1100 Series Wireless Antenna Connections
XT30/XT50 Installation Guide
Digital Monitoring Products
15
COMPLIANCE
On-Board 1100 Series Wireless Antenna Connection
18.1 Wireless Antenna
The XT50 Wireless Antenna terminal block J20 is located at the top right corner of the circuit board. The
antenna installs through a small opening in the top of the enclosure and is attached to the panel using the
right terminal. The left terminal is not used.
The XT50 built-in wireless operates with DMP 1100 Series transmitters. See section 3.4 for a list of accessory
devices.
18.2 LED Operation
Green (TX): With a wireless house code enabled, the green LED flashes every time the receiver transmits
(32 times per second). If a house code is not programmed in the panel, the panel is reset, or the panel is
powered off, the green LED will be off. Under normal operation, the green LED flashes constantly with no
interruption or change.
Yellow (RX): The yellow LED flashes every time the receiver hears a message from a programmed wireless
transmitter. When a message is sent by a transmitter, typically by pressing or releasing the tamper switch,
the yellow LED should flash indicating that the receiver received a message from the transmitter. If the
LED never flashes, the transmitter is not getting through to the receiver. This could be because of a
misprogrammed serial number or the transmitter is too far away. Under normal operation, the yellow LED
will flash at every trip of every wireless transmitter and occasionally when the transmitters perform their
periodic check-in. It is not unusual for this LED to stay off for many minutes at a time when no transmitters
are communicating.
Wireless Keypads
19.1 Mounting Keypads
DMP keypads have removable covers that allow the base to be mounted on a wall, desk stand or other flat
surface using the screw holes provided on each corner.
19.2 Wireless Keypad Association
Enable Wireless Keypad Association operation on both the keypad and panel.
To enable association operation in the keypad, access the Installer Options
Menu (3577 (INST)) and select RF Survey). The keypad logo LEDs turn on Red
until association is successful.
RCV
J8
XMIT
Programming
To enable association operation in the XT30/XT50 panel, reset panel 3 times
within 12 seconds. Allow the keypad bus Transmit/Receive LEDs to turn back
on between each reset.
For 60 seconds the panel listens for wireless keypads that are in the Installer Options Menu (3577 CMD) and
have not been programmed, or associated into another panel. Those keypads are assigned to the first open
device position automatically based upon the order in which they are detected. The keypad logo turns Green
to indicate it has been associated with the panel.
Digital Monitoring Products
16
XT30/XT50 Installation Guide
COMPLIANCE
Listed Compliance Specifications
20.1 Introduction
The programming and installation specifications contained in this section must be completed when installing
the XT30/XT50 in accordance with any of the ANSI/UL burglary standards. Additional specifications may be
required by a particular standard.
20.2 Bypass Reports
The bypass reports must be programmed as YES for all listed burglary applications.
20.3 Current Draw
The total current draw from a combination of auxiliary, smoke, and bell output terminals must not exceed
1.6 Amps.
20.4 Battery Standby
Use battery Models 365 (12 VDC 9Ah) or 366 (12 VDC 18Ah) with the XT30/XT50 panel when installed in the
340, 341, 349, or 349A enclosures. The Model 364 (12 VDC 1.3Ah) battery is for use with the XT30/XT50
panel when using the 341 enclosure with the optional 341B Battery Bracket. The Model 364 battery is rated
for 4 hours of standby time.
20.5 Auxiliary and Bell Current
For UL listed applications, the maximum auxiliary current is 400mA, and the maximum bell current is 500mA.
20.6 Cross Zoning
Each zone must have the capability of protecting the common area individually.
20.7 Software Version
For UL listed applications, the minimum software version must be Version 103.
20.8 App Key
The Remote Option App Key has not been evaluated for use in listed applications.
Household Burglar-Alarm System Units
21.1 Bell Cutoff
ANSI/UL 1023
The bell cutoff time cannot be less than four minutes.
21.2 Entry Delay
The maximum entry delay used must not be more than 45 seconds.
21.3 Exit Delay
The maximum exit delay used must not be more than 60 seconds.
21.4 Wireless External Contact
When used, the External Contact of 1101, 1102 or 1105 must be programmed Normally Closed.
21.5 Wireless Supervision Time
The Zone Information Supervision Time cannot be set to 0 (zero).
21.6 Wireless Audible Annunciation
The Wireless Audible option must be selected as DAY for residential applications.
21.7 Panel location
Mount panel inside protected area.
21.8 Test Frequency
The Test Frequency option must be programmed to send a report at least once every 30 days.
Digital Burglar Alarm Communicator System Units
22.1 Entry Delay
ANSI/UL 1635
The maximum entry delay used must not be more than 60 seconds.
22.2 Exit Delay
The maximum exit delay used must not be more than 60 seconds.
22.3 Test Frequency
The Test Frequency option must be programmed to send a report once every 24 hours.
22.4 Automatic Bell Test
This option must be programmed as YES.
XT30/XT50 Installation Guide
Digital Monitoring Products
17
COMPLIANCE
Central Station Burglar Alarm Units
ANSI/UL 1610
23.1 Central Station
Digital Dialer Central Station (DACT) service for commercial application can be provided by adding a listed
local audible signal appliance and placing the XT30 or XT50 panel into the Model 349A Attack Resistant
Enclosure.
23.2 Remote Disarm
REMOTE DISARM must be programmed as NO.
23.3 Central Station
MESSAGE TO TRANSMIT programming for zones must not be set to LOCAL (L).
Household Fire Warning System
ANSI/UL 985 NFPA 72 Specifications
24.1 Bell Output Definition
The bell output of the Model XT30/XT50 must be programmed to operate steady on burglary alarms and
temporal on fire alarms. See the XT30/XT50 Programming Guide.
24.2 Household System
An alarm sounding device must be installed indoors so that it is clearly heard in all sleeping areas.
24.3 Household Fire Warning
Recognized limited energy cable must be used for connection of all initiating, indicating, and supplementary
devices.
24.4 Wireless Supervision Time
The Zone Information Supervision Time must be 3 minutes for fire devices. See the XT30/XT50 Programming
Guide.
24.5 Wireless Fire Verification
When used, the Model 1161 and 1162 wireless smoke detectors must not be programmed as Fire Verification
(FV) zone type. See the XT30/XT50 Programming Guide.
24.6 Battery Standby
For UL listed applications, the panel must have 24 Hour battery standby operation. The Model 364 battery
should not be used for fire installations.
24.7 Alarm Verification
Alarm Verification must only be enabled on smoke detectors that do not employ an integral alarm
verification feature.
24.8 Model 860
When using the Model 860 Relay Output, a fire and non-fire device must not share a relay.
24.9 Test Frequency
The Test Frequency option must be programmed to send a report at least once every 30 days.
California State Fire Marshal Specifications
25.1 Bell Output Definition
The bell output of the Model XT30/XT50 must be programmed to operate steady on burglary alarms and
temporal on fire alarms.
Digital Monitoring Products
18
XT30/XT50 Installation Guide
COMPLIANCE
False Alarm Reduction Programmable Options
ANSI/SIA CP-01-2010
26.1 Shipping Defaults and Recommended Programming
SIA CP-01 FEATURE
PARAGRAPH # AND
DESCRIPTION
DMP PROGRAMMING
GUIDE LT‑0981
SECTION #
REQUIREMENT
Required
(Programmable)
4.2.2.1 Exit Time
8.6 Exit Delay
4.2.2.2 Progress
Annunciation
13.14 Prewarn Address Allowed
4.2.2.3 Exit Time Restart 8.6 Exit Delay
Required Option
RANGE
SHIPPING
DEFAULT
RECOMMENDED
PROGRAMMING*
45 sec. - 250 sec.
60
Seconds
60 Seconds
Individual keypads
may be disabled per
zone
All
keypads
enabled
All keypads enabled
For re-entry during
exit time
Enabled
Enabled
Required Option
4.2.2.5 Auto Stay Arm on 8.17 Occupied Premise
(except for
Unvacated Premises
- See Install Guide
remote arming)
Occupied Premise NO/
Enabled
YES option
Enabled Yes
for Residential
Applications
4.2.4.4 Exit Time and
Not Available on
Progress Annunciation/
Remote Arming
Disable - for Remote Arm
Allowed Option
Progress Annunciation
Always disabled for
Remote Arming
Not
Available
Remote Arming not
allowed for CP-01
installations.
4.2.3.1 Entry Delay(s)
8.5 Entry Delay
Required
(Programmable)
30 sec. – 240 Sec. **
30
Seconds
At least 30 Seconds **
4.2.5.1 Abort Window –
for Non‑Fire Zones
3.3 Transmit Delay
Required Option
Disable by zone or
zone type
Enabled
NT DY EX
Zone
Enabled
4.2.5.1 Abort Window
Time – for Non-Fire
Zones
3.3 Transmit Delay
Required
(Programmable)
20 sec., 30 sec., or
40 sec. **
30
Seconds
At least 20 Seconds **
4.2.5.1.2 Abort
Annunciation
3.3 Transmit Delay
Required Option
Annunciate that no
Yes
alarm was transmitted
Yes
4.2.5.4.1 Cancel
Annunciation
Always Enabled - Not
Programmable
Required Option
Annunciate that
a Cancel was
transmitted (S49)
Always
Enabled
Yes
4.2.6.1 & 4.2.6.2 Duress
Feature
User Code + 1 =
Ambush Code Not
Available
Allowed Option
No 1 + derivative of
another user code/no
duplicates with other
user codes
Code +1
Always
Disabled
Not Programmable
4.3.1 Cross Zoning
13.16 Cross Zone
Required Option
Yes/No Zone
Programming
No
Enabled using two or
more programmed
zones
4.3.1 Programmable
Cross Zoning Time
8.7 Cross Zone Time
Allowed
4 sec. - 250 sec.
0 Seconds
Per walk path in
protected premises
4.3.2 Swinger Shutdown
Not Available — Always
Required
On
1-6 trips
2 trips
2 trips
4.3.2 Swinger Shutdown
Disable
13.13 Swinger Bypass
Allowed
For non-police
response zones
Yes
Enabled (all zones)
4.3.3 Fire Alarm
Verification
13.5 Zone Type
Required Option
FV Type Zone
No
Yes as required (unless
sensors can self verify)
3.17 First Telephone
Number
Required Option
Include *70P in
Enabled if user has
Disabled
Telephone Number
call waiting
Test all protection
N/A
N/A
17.5 Walk Test
Allowed
4.6.3 System Test
devices
17.5 Walk Test
Not Allowed
4.6.5 Communications
N/A
N/A
N/A
* Programming at installation may be subordinate to other listed requirements for the intended application.
** For listed Installations, combined Entry Delay and Transmit Delay should not exceed 1 minute.
4.5 Call Waiting Cancel
XT30/XT50 Installation Guide
Digital Monitoring Products
19
COMPLIANCE
26.2 Call Waiting
The Call Waiting default setting is disabled. To cancel the Call Waiting feature, program * (star) 7 0 P
(pause), the standard telephone code prefix that cancels call waiting, into the telephone number string.
Cancel Call Waiting for telephone lines that have Call Waiting operational on the telephone line. See the
XT30/XT50 Programming Guide.
Caution: A call waiting cancel programmed on a non-call waiting telephone line, would prevent
communication to the central station.
26.3 Entry Delay
Only use Entry Delay 1. Do not use Entry Delay 2. See the XT30/XT50 Programming Guide.
26.4 Local Bell
All non-fire zones such as Night, Day, Exit, Aux1 and Aux 2 must be programmed for local bell enabled with a
bell cutoff time set to a minimum of 6 minutes to provide a cancel window of 5 minutes or greater. This does
not apply to manually operated zone types such as Panic and Emergency.
26.5 Minimum Installation Requirements
SIA CP-01-2010 minimum system installation requirements include an XT30 or XT50, a local Bell, and off
premise DACT communication to an SCS-1R receiver plus one of the following compatible keypads.
7060, 7063, 7070, 7073, 7160, 7163, 7170, or 7173 Thinline™ keypads
7060A, 7063A, 7070A, or 7073A Aqualite™ keypads
7360 or 7363 Thinline™ Icon keypads
7760 Clear Touch™ keypad
7872 or 7873 Graphic Touchscreen Keypads
Digital Monitoring Products
20
XT30/XT50 Installation Guide
COMPLIANCE
27.1 Troubleshooting Section
Troubleshooting
This section provides troubleshooting information for use when installing or servicing an XT30/XT50 system.
Problem
Possible Cause
Keypad displays “SYSTEM TROUBLE”
Keypad keyboard is not functional.
When a key is pressed, only a short
beep is emitted.
Keypad XMIT Green LED is off
Keypad RCV Yellow LED is off
Possible Solutions
J16 Jumper is installed.
Remove the J16 reset jumper.
Open or short on the green data wire to
the keypad.
Check for broken or shorted wires between
the panel and the keypad.
Bad keypad or zone expander is affecting
the Green data wire.
Replace keypad or zone expander.
Open or short on the yellow data wire to
the keypad.
Check for broken or shorted wires between
the panel and the keypad.
Bad keypad or zone expander. is affecting
the Yellow data wire.
Replace keypad or zone expander.
Panel is reset.
Remove J16 jumper.
Flash Load enabled.
Remove J18 jumper and reset panel.
Keypad/expanders are not connected to panel.
Connect keypad/expanders.
Keypad/expanders are greater than five.
Check keypad/expanders address.
Keypad beeps when keys are pressed,
but will not allow the user to arm or
disarm, or enter the User Menu.
Two or more keypads are assigned to the
same address.
Set each keypad on the system to a unique
address.
Power LED is off.
AC/Battery is not connected.
Connect AC power and/or battery.
Overcurrent OVC LED turns Red
Too many devices attached to auxiliary.
Maximum current draw is 500 mA.
Wireless Green TX LED is off.
Wireless House Code is not programmed.
Program House Code in System Options.
Wireless Yellow RX LED never flashes.
Transmitters are not getting through to
receiver.
Wireless Green TX and Yellow RX
LEDs are both on steady
Keypad operates intermittently,
keystrokes may be missed, or display
does not update consistently.
Check transmitter serial numbers.
Move transmitter closer.
If XT30, replace 1100 series receiver.
Panel is reset.
Remove J16 jumper.
Flash Load enabled
Remove J18 jumper and reset panel.
Wire length may exceed maximum,
resulting in poor data performance.
Wire length can be reduced or a heavier
gauge used.
A power supply can be added near the keypad.
Aee LT-2031, LX-Bus/Keypad Bus Wiring
Application Note for more information.
27.2 Common LCD Keypad Displays
Listed below are several keypad messages you may see on the display. Follow the instructions in the Possible
Solutions column to correct the problem.
Message
Meaning
Possible Solutions
INVALID CODE
The user code entered is not recognized by the system. Check the user code and try again.
CLOSING TIME
The system was not armed at its scheduled closing
time.
Users still on the premise should arm the system or
extend the schedule to a later time.
AC TROUBLE
The system is not getting proper AC power.
Check that the AC connections are good from the
transformer.
BATTERY TROUBLE
The battery is either low or missing.
Check to see that battery and connections are good.
SYSTEM BUSY
The system is performing another task with a
higher priority or is being Remote Programmed.
Wait a few moments for the system to complete the
task. Make sure the J16 jumper is not on the panel. If
the message displays for several minutes, the keypad
is not receiving polling from the panel.
TRANSMIT FAIL
The panel has attempted to communicate with
the central station multiple times and has not
succeeded.
Verify your communication type, account number,
and phone number. Make sure the telephone line is
connected and working properly.
XT30/XT50 Installation Guide
Digital Monitoring Products
21
Digital Monitoring Products
22
1k W
Bell T rouble
Bell T rouble
Bell B Ð Output
Bell B + Output
Bell A Ð Output
10
11
Bell A + Output -
Bell Power Ð Input
Bell Power + Input
Alarm Input
Ground
Auxiliary Power
Power Supply
Trouble Contacts
N/C
AUXILIARY
POWER
SUPPLY
DMP Model 865
85mA at 12 VDC
12 or 24 VDC
5 Amp Maximum
Notification Circuit Module
12 or 24 VDC
5 Amp Maximum
Bell T rouble
Bell T rouble
Bell Output -
Bell Output +
Bell Power Input
Alarm Input
Ground
Auxiliary Power
DMP Model 866
37mA at 12 VDC
Notification Circuit Module
Style W
AUXILIARY
POWER
SUPPLY
Power Supply
Trouble Contacts
N/C
NOTE: If an auxiliary supply is not used,
terminals 3 and 4 on the 866 Indicating
Circuit Module can be jumpered together
to supply bell power from the XT30 panel.
Each 865 Notification Circuit Module
in alarm draws up to 85mA from its
terminal 3 alarm input.
UL Listed, Polarized
Indicating Devices.
Style Z
Each 866 Indicating Circuit Module
in alarm draws up to 35mA from its
terminal 3 alarm input.
UL Listed, Polarized
notification Devices.
10k W EOL Resistor
DMP Model 308
Optional Module installation
J3
Phone Line
J8
Programming
RED
S = Supervised Circuit
J1
Ethernet
The Auxiliary Power Supply and Indicating Circuit Module
trouble contact zone must be programmed as a Supervisory
Type zone and must be selected for display in the keypad
status list.
J7 RJ
Supervision
J24 Cellular
header
J16
Reset
J18
Load
J11
Outputs
J20
Wireless
Antenna
connection
Troubleshooting
Wiring Diagrams
28.1 Multiple Indicating Circuit Modules Installation
XT30/XT50 Installation Guide
Wiring Diagrams
28.2 System Sensor 2-Wire Smoke Detectors
XT30/XT50 Panel
TX RX
Wireless LEDs
J7 RJ
Supervision
J3
Phone Line
J11
J1
Ethernet
Outputs
OVC LED
RCV
Power
LED
J16
Reset
J8
XMIT
Programming
RED
BLACK
PURPLE
TEMPORAL
to transformer
470 Ohm or
(2) 1k in Parallel
RRS-MOD
SYSTEM SENSOR REVERSING
RELAY/SYNCHRONIZATION
MODULE
T+
PWR +
PWR OUT +
OUT IN +
IN -
2W-MOD2
SYSTEM SENSOR LOOP
TEST & MAINTENANCE MODULE
3.3K
Z10+
Z10-
12
11
10
SMK
GND
IN+
IN-
Orange
Yellow
White
Brown
3.9K EOL
SYSTEM SENSOR 2WTA-B or 2WTR-B
SMOKE DETECTORS
+ -
RA
XT30/XT50 Installation Guide
-A
+ -
RA
-A
Digital Monitoring Products
23
Revisions
Revisions to This Document
This section explains the changes that were made to this document during this revision. This section lists the
version, section number with heading, and a quick summary of the change.
Ver.
1.14
1.13
1.12
1.11
1.10
Section Number and Heading
3.3 Accessory Devices
6.7 Standby Battery Calculations
17.1 Cellular
Listings and Approvals
1.7 Enclosure Specifications
24.4 Wireless External Contact
3.3 Accessory Devices
3.3 Accessory Devices
6.7 Standby Battery Calculations
17.1 Cellular
1.2 Communication
4.1 Mounting the Enclosure
6.7 Standby Battery Calculations
15.1 Reset Header J16 Description
17.1 Cellular
28.1 Multiple Indicating Circuit...
Digital Monitoring Products
24
Summary of Changes
Removed 1126W
Added 860 to table
Updated cellular options
Updated FCC, removed UL
Added Construction Information
Removed 1101, 1102, and 1105 section
Added 7872/7873 references
Added 263C/263G/263H information
Added 263H information
Added 263H references
Added modular cell communication
Updated enclosure diagrams
Added 263C reference
Updated panel diagram
Added 263C references
Updated diagram
XT30/XT50 Installation Guide
XT30/XT50 Installation Guide
Digital Monitoring Products
25
800 - 641 - 4282
Intrusion
•
fire
•
Access
•
Networks
www.dmp.com
2500 North Partnership Boulevard
Designed, Engineered and
Assembled in U.S.A.
S p r i n g fi e l d , M i s s o u r i 6 5 8 0 3 - 8 8 7 7
13515
California State Fire Marshal (CSFM)
ETL: ANSI/SIA CP-01 False Alarm Reduction
ANSI/UL 1023 Household Burglar
ANSI/UL 985
Household Fire Warning
ANSI/UL 1610 Central Station Burglar
ANSI/UL 1635 Digital Burglar
FCC Part 15 ID: CCKPC0128
FCC Part 68 Registration ID CCKAL00BXT50
Industry Canada ID: 5251A-PC0128
LT-0980 1.14 © 2013 Digital Monitoring Products, Inc.
Listings and Approvals

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.7
Linearized                      : Yes
Create Date                     : 2014:01:13 10:27:08-06:00
Creator                         : Adobe InDesign CS5.5 (7.5)
Modify Date                     : 2014:01:21 16:04:45-06:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Metadata Date                   : 2014:01:21 16:04:45-06:00
Creator Tool                    : Adobe InDesign CS5.5 (7.5)
Page Image Page Number          : 1, 2
Page Image Format               : JPEG, JPEG
Page Image Width                : 256, 256
Page Image Height               : 256, 256
Page Image                      : (Binary data 6904 bytes, use -b option to extract), (Binary data 9116 bytes, use -b option to extract)
Version ID                      : 1
Instance ID                     : uuid:0d5b0d78-dde1-4f13-bf9f-77b633d12c87
Document ID                     : xmp.did:5E9AEB71E660E311BFC0FE0C97FECA8E
Original Document ID            : adobe:docid:indd:2c738f9e-e9b8-11de-9df9-df3494c0ba00
Rendition Class                 : proof:pdf
Contributor Resources Document ID: uuid:3d84355f-3bcc-4804-9608-e87d100e98ca
Derived From Instance ID        : xmp.iid:66EA835DE660E311BFC0FE0C97FECA8E
Derived From Document ID        : xmp.did:FCDDB388690AE31186B0BC75B5D2DCBA
Derived From Original Document ID: adobe:docid:indd:2c738f9e-e9b8-11de-9df9-df3494c0ba00
Derived From Version ID         : 1
Derived From Rendition Class    : default
History Action                  : saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved
History Instance ID             : xmp.iid:8694D4073B3DE111A33596ADCD36BB1F, xmp.iid:8794D4073B3DE111A33596ADCD36BB1F, xmp.iid:3C03F51E3C3DE111A33596ADCD36BB1F, xmp.iid:6E8F72483C3DE111A33596ADCD36BB1F, xmp.iid:5AE70EA53C3DE111A33596ADCD36BB1F, xmp.iid:C8D95C2D123EE11198D3EE0F35477EBE, xmp.iid:1A397BB5153EE11198D3EE0F35477EBE, xmp.iid:7CE0C8A4163EE11198D3EE0F35477EBE, xmp.iid:1396BCD8213EE11198D3EE0F35477EBE, xmp.iid:B5DB8E2E223EE11198D3EE0F35477EBE, xmp.iid:19D9B3018440E1119D5280CFA46E168A, xmp.iid:C98ACBE78440E1119D5280CFA46E168A, xmp.iid:ED68AE0D8540E1119D5280CFA46E168A, xmp.iid:C602E0818640E1119D5280CFA46E168A, xmp.iid:21649A888840E1119D5280CFA46E168A, xmp.iid:E2ABE24AB543E111BDF98482B3E801C7, xmp.iid:15C44705B643E111BDF98482B3E801C7, xmp.iid:ED1AF42FB643E111BDF98482B3E801C7, xmp.iid:950E192C1046E1118B08DE766A3E77B2, xmp.iid:9F21E00E7D4EE111B5AB9F292F3C1DE9, xmp.iid:978DAF3C814EE111B5AB9F292F3C1DE9, xmp.iid:B2532025A451E111831EB6122485A7BB, xmp.iid:2E8E10B3D851E111B64BF084E8079916, xmp.iid:D89C550AD951E111B64BF084E8079916, xmp.iid:412776605977E1118B24FE87A9B5C254, xmp.iid:3DF056071B78E1118F8EEC1254000C2A, xmp.iid:1716FF591C78E1118F8EEC1254000C2A, xmp.iid:E8894D181D78E1118F8EEC1254000C2A, xmp.iid:045E397A1E78E1118F8EEC1254000C2A, xmp.iid:15FF4ED21E78E1118F8EEC1254000C2A, xmp.iid:F0CC4C6D5078E111B263C50C5EB83995, xmp.iid:AAA8D5502180E111A27DB464312F0F2F, xmp.iid:C335AC097EAEE1119C95A398A0B9457E, xmp.iid:284CB93A77D6E11185CDAE2BF86BEA31, xmp.iid:DFB6780078D6E11185CDAE2BF86BEA31, xmp.iid:88896F8404E0E111ACECBE1A6662955C, xmp.iid:00B30D5ED5E0E111A923C996AD2B54C9, xmp.iid:B5EA7164D0EAE111851281A1FF9A67D7, xmp.iid:253C3B2A49F0E1119C63E87865AA53C6, xmp.iid:9A0ECD4C03F2E11184E497B0D0950136, xmp.iid:CA247DE86006E2119EFDF6E8FB5C0CF1, xmp.iid:3851AC72E80BE2118C98C56DA427BA96, xmp.iid:B008F11FA214E211A9D7AD8116B18D73, xmp.iid:133BCD90CA16E2119ABEFAD8DA7702ED, xmp.iid:9654A8ACCA16E2119ABEFAD8DA7702ED, xmp.iid:9754A8ACCA16E2119ABEFAD8DA7702ED, xmp.iid:567F7A65CB16E2119ABEFAD8DA7702ED, xmp.iid:287059D96A19E2118A48A568EDD8E6F5, xmp.iid:C4C75AA42725E211B9649D10757748DE, xmp.iid:1E5C2AA83B5FE211AFFDDCD7AF077648, xmp.iid:7A5FF4293C5FE211AFFDDCD7AF077648, xmp.iid:A75B510D0D6BE211964CC56573E652DC, xmp.iid:3544F4380F6BE211964CC56573E652DC, xmp.iid:3644F4380F6BE211964CC56573E652DC, xmp.iid:D61223420F6BE211964CC56573E652DC, xmp.iid:D71223420F6BE211964CC56573E652DC, xmp.iid:D81223420F6BE211964CC56573E652DC, xmp.iid:D91223420F6BE211964CC56573E652DC, xmp.iid:DAD7BD1DAD6BE211801ABCB10412F64E, xmp.iid:267203A0B16BE211801ABCB10412F64E, xmp.iid:F9F4FFB71F72E211994DAF660557C8D1, xmp.iid:8C128E5AF184E211938A8D1737562AEA, xmp.iid:A14612BCB9A2E211AF5AF493FD79C9E9, xmp.iid:DDC420C371DEE211B38186ECF94E1E20, xmp.iid:EBEC92F671DEE211B38186ECF94E1E20, xmp.iid:CE064B0EB6E5E211AD5CDD12E6D79D59, xmp.iid:A3673623B6E5E211AD5CDD12E6D79D59, xmp.iid:1E9C60DA8AE9E21187C7F06F3D5AB955, xmp.iid:912518908BE9E21187C7F06F3D5AB955, xmp.iid:169C68118CE9E21187C7F06F3D5AB955, xmp.iid:5E6413888CE9E21187C7F06F3D5AB955, xmp.iid:A62C208A92E9E21187C7F06F3D5AB955, xmp.iid:91296633A3E9E21187C7F06F3D5AB955, xmp.iid:05E1EAC533EAE2119799970E884C2B94, xmp.iid:7A477FFB670AE31186B0BC75B5D2DCBA, xmp.iid:FCDDB388690AE31186B0BC75B5D2DCBA, xmp.iid:FDDDB388690AE31186B0BC75B5D2DCBA, xmp.iid:A627C8216C0AE31186B0BC75B5D2DCBA, xmp.iid:80C18ECC6D0AE31186B0BC75B5D2DCBA, xmp.iid:237C54E0440BE3119D44810BF993636C, xmp.iid:94796FA8450BE3119D44810BF993636C, xmp.iid:B3E94CAC2A0FE3118DF2D60B22969A8E, xmp.iid:B16B103C2D0FE3118DF2D60B22969A8E, xmp.iid:66EA835DE660E311BFC0FE0C97FECA8E, xmp.iid:5E9AEB71E660E311BFC0FE0C97FECA8E, xmp.iid:DBC313EA0961E311895694CB455B967F, xmp.iid:9336B7FD0961E311895694CB455B967F, xmp.iid:F624F7510D61E311895694CB455B967F, xmp.iid:DDF2B4970D61E311895694CB455B967F, xmp.iid:AEC7E8210E61E311895694CB455B967F, xmp.iid:9972885B0E61E311895694CB455B967F, xmp.iid:9E43CD8B0E61E311895694CB455B967F, xmp.iid:6B9A62B81361E311895694CB455B967F, xmp.iid:06A0BDCC1361E311895694CB455B967F, xmp.iid:08307B1F6A62E3119F50A8A73E475A85, xmp.iid:911C53DE7762E3119F50A8A73E475A85, xmp.iid:1954F3139166E31192C0FF396FF95F3B, xmp.iid:13B35BE00069E311B2C3C6C23CB73279, xmp.iid:8F3B435F8269E31194F596389D8D19D0, xmp.iid:641447608369E31194F596389D8D19D0, xmp.iid:9DE1B6EA8369E31194F596389D8D19D0, xmp.iid:9B8BC429DE6BE311B6F8A98D9FE6A782, xmp.iid:C62E2C7BDF6BE311B6F8A98D9FE6A782, xmp.iid:3EDD93446D7CE31191F9B9AFA39258BD, xmp.iid:2B0A31866F7CE31191F9B9AFA39258BD
History When                    : 2012:01:12 10:32:34-06:00, 2012:01:12 10:32:34-06:00, 2012:01:12 10:40:22-06:00, 2012:01:12 10:41:32-06:00, 2012:01:12 10:44:07-06:00, 2012:01:13 12:12:38-06:00, 2012:01:13 12:37:55-06:00, 2012:01:13 12:44:37-06:00, 2012:01:13 14:04:48-06:00, 2012:01:13 14:07:12-06:00, 2012:01:16 14:52:30-06:00, 2012:01:16 14:58:56-06:00, 2012:01:16 15:00-06:00, 2012:01:16 15:10:24-06:00, 2012:01:16 15:24:54-06:00, 2012:01:20 16:22:52-06:00, 2012:01:20 16:28:04-06:00, 2012:01:20 16:29:16-06:00, 2012:01:23 16:18:27-06:00, 2012:02:03 09:38:02-06:00, 2012:02:03 10:07:57-06:00, 2012:02:07 09:55:23-06:00, 2012:02:07 16:11:36-06:00, 2012:02:07 16:14:02-06:00, 2012:03:26 10:35:55-05:00, 2012:03:27 09:42:08-05:00, 2012:03:27 09:51:36-05:00, 2012:03:27 09:56:55-05:00, 2012:03:27 10:06:49-05:00, 2012:03:27 10:09:17-05:00, 2012:03:27 16:04:22-05:00, 2012:04:06 14:47:17-05:00, 2012:06:04 14:46:54-05:00, 2012:07:25 11:38:57-05:00, 2012:07:25 11:44:29-05:00, 2012:08:06 15:23-05:00, 2012:08:07 16:18-05:00, 2012:08:20 09:07:35-05:00, 2012:08:27 08:14:43-05:00, 2012:08:29 12:59:38-05:00, 2012:09:24 11:00:06-05:00, 2012:10:01 11:52:56-05:00, 2012:10:12 14:22:12-05:00, 2012:10:15 08:16:44-05:00, 2012:10:15 08:17:31-05:00, 2012:10:15 08:19:27-05:00, 2012:10:15 08:22:41-05:00, 2012:10:18 16:29:07-05:00, 2012:11:02 14:58:16-05:00, 2013:01:15 11:47:40-06:00, 2013:01:15 11:51:18-06:00, 2013:01:30 12:44:17-06:00, 2013:01:30 12:59:50-06:00, 2013:01:30 13:00:05-06:00, 2013:01:30 13:00:05-06:00, 2013:01:30 13:00:21-06:00, 2013:01:30 13:00:21-06:00, 2013:01:30 13:24:16-06:00, 2013:01:31 07:59:56-06:00, 2013:01:31 08:22:21-06:00, 2013:02:08 12:45:33-06:00, 2013:03:04 11:31:31-06:00, 2013:04:11 10:08:58-05:00, 2013:06:26 10:04:56-05:00, 2013:06:26 10:06:22-05:00, 2013:07:05 16:01:26-05:00, 2013:07:05 16:02:01-05:00, 2013:07:10 13:07:19-05:00, 2013:07:10 13:07:20-05:00, 2013:07:10 13:10:57-05:00, 2013:07:10 13:14:16-05:00, 2013:07:10 13:57:16-05:00, 2013:07:10 15:56:32-05:00, 2013:07:11 09:11:25-05:00, 2013:08:21 08:56:52-05:00, 2013:08:21 08:56:53-05:00, 2013:08:21 09:12:10-05:00, 2013:08:21 09:15:29-05:00, 2013:08:21 09:27:25-05:00, 2013:08:22 11:07-05:00, 2013:08:22 11:12:35-05:00, 2013:08:27 10:09:30-05:00, 2013:08:27 10:27:50-05:00, 2013:12:09 09:27:42-06:00, 2013:12:09 09:27:42-06:00, 2013:12:09 13:41:36-06:00, 2013:12:09 13:42:09-06:00, 2013:12:09 14:05:58-06:00, 2013:12:09 14:07:55-06:00, 2013:12:09 14:11:47-06:00, 2013:12:09 14:13:24-06:00, 2013:12:09 14:14:45-06:00, 2013:12:09 14:51:47-06:00, 2013:12:09 14:52:21-06:00, 2013:12:11 07:42:48-06:00, 2013:12:11 09:21:12-06:00, 2013:12:16 14:31:44-06:00, 2013:12:19 16:57:03-06:00, 2013:12:20 08:24:01-06:00, 2013:12:20 08:31:12-06:00, 2013:12:20 08:35:05-06:00, 2013:12:23 08:26:07-06:00, 2013:12:23 08:35:34-06:00, 2014:01:13 10:10:49-06:00, 2014:01:13 10:26:58-06:00
History Software Agent          : Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5
History Changed                 : /;/metadata, /metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /metadata, /;/metadata, /metadata, /, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata
Doc Change Count                : 4850
Format                          : application/pdf
Producer                        : Adobe PDF Library 9.9
Trapped                         : False
Page Count                      : 31
EXIF Metadata provided by EXIF.tools
FCC ID Filing: CCKPC0128

Navigation menu