Digital Security Controls 12WIFI422SCW WiFi Module for DSC Impassa Alarm System User Manual DRAFT 29008546R001 WIFI422SCW INIS ENG ONLY

Digital Security Controls Ltd. WiFi Module for DSC Impassa Alarm System DRAFT 29008546R001 WIFI422SCW INIS ENG ONLY

user - installation manual

Download: Digital Security Controls 12WIFI422SCW WiFi Module for DSC Impassa Alarm System User Manual DRAFT 29008546R001 WIFI422SCW INIS ENG ONLY
Mirror Download [FCC.gov]Digital Security Controls 12WIFI422SCW WiFi Module for DSC Impassa Alarm System User Manual DRAFT 29008546R001 WIFI422SCW INIS ENG ONLY
Document ID1862887
Application IDg4yU2Op4wyKNxjo/geJOvw==
Document Descriptionuser - installation manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize64.3kB (803812 bits)
Date Submitted2012-12-18 00:00:00
Date Available2012-12-19 00:00:00
Creation Date2012-12-12 09:37:26
Producing SoftwareAcrobat Distiller 9.5.2 (Windows)
Document Lastmod2012-12-18 09:36:51
Document TitleDRAFT_29008546R001_WIFI422SCW_INIS_ENG_ONLY.fm
Document CreatorPScript5.dll Version 5.2.2
Document Author: tvecchiarelli

WIFI422SCW MODULE INSTALLATION SHEET
Introduction
[922] SSID Display
The WIFI422SCW module provides a wireless link from the host security control panel to
the C24 Interactive gateway. This manual provides installation and setup information for
WiFi422SCW only.
Enter section [851][922] to obtain the SSID of the currently enrolled Access Point.
The keypad will display the SSID of the network that it is using. If the WiFi422SCW is
not connected to any Access Point, the keypad will display “X” to indicate the network
connection has not been created.
Features & Specifications
•
•
•
•
•
•
•
RS-422 interface
SSID indication (SCW variant)
Signal strength indication
Reset via PGM
SW WPS Setup
WPA2 PSK
UART Serial Data Rate: 115200bps
•
•
•
•
•
•
Dimensions: 64mm × 24.71 mm
Indoor range: 32m (120ft)
Outdoor range: 95m(300ft)
Power consumption: 66mA (max.) / 12V
Humidity: 85%, non-condensing
Wi-Fi Data Rate: 802.11 b/g
[923] Signal Strength Display
Enter section [851][923] to view the Wi-Fi signal strength.
Once in this section, the keypad will display the signal strength with respect to the Access
Point it is currently using. If the WiFi422SCW is not associated with any Access Point,
the Keypad will display “X------”
NOTE: This section is available on the display of the control panel only.
Table 2: Signal Strength Display
Compatibility
This module is compatible with the following SCW control panels: SCW9055-SM-433,
SCW9055D-SM-433, SCW9055G-SM-433, SCW9055I-SM-433, SCW9057-SM-433,
SCW9057D-SM-433, SCW9057G-SM-433, SCW9057I-SM-433.
Installation and Wiring
Insert WIFI422SCW module into the SCW905X backplate. Refer to Table 1 below for
wiring details.
Table 1: WIFI422SCW Module Wiring Connections
From WIFI422SCW Module
To SCW905X(D)(G)(I)
Red
Black
Brown
White
Yellow
Blue
Green
Aux+ terminal block on the panel
Aux- terminal block on the panel
1 I/O terminal block on the panel
Rx- terminal block on communicator
Rx+ terminal block on communicator
Tx - terminal block on communicator
Tx+ terminal block on communicator
Less than -85
-85 to -76
-75 to -66
-65 to -56
-55 to -46
-45 and up
Troubleshooting
Trouble
Solution
Signal strength is below 3 bars (see Table
2)
Error tone being generated / unable to
enter WiFi422SCW section
WiFi422SCW unable to connect to AP
Relocate the system until 3 bars or higher
is observed.
Check WiFi422SCW wiring
Perform a power cycle
+TX- +RX- GND
BLUE
YELLOW
BROWN
WIFI422SCW
RED
Setup & Programming
RSSI Value
No signal
1 Bar
2 Bars
3 Bars
4 Bars
5 Bars
FCC/IC
Figure 1: WIFI422SCW Module Wiring
GREEN
Signal Strength
WHITE
BLACK
AC +AUX- 1 I/O 2 R T
R1 T1
This modular transmitter is labeled with its own FCC ID and IC number. When the module is installed inside the host device and the FCC ID/IC of the module is not visible the
host device shall display the provided label referring to the FCC ID and IC of the enclosed
module. This label is shipped together with the module and it is the responsibility of the
integrator to apply it to the exterior of the enclosure as indicated below.
FCC/IC Label
SCW905X
The WIFI422SCW module receives power from the control panel AUX output and it
communicates via the RS-422 interface on the 3G2055-SM-NA or TL2553G-SM-NA
communicators.
1. Enter section [851][920].
• The communicator will send a command to initiate Wi-Fi Protected Setup (WPS).
• The message “WPS Success” is displayed when setup is complete.
PGM Attribute
Please refer to the SCW9055/9057 Installation Manual to configure PGM1 to Pulse. The
default configuration (5 seconds) is recommended.
[920] Initiate Protected Setup
Upon entering this section the WIFI422SCW module shall initiate WPS and connect to
the nearest Access Point (AP) also performing WPS. The LCD shall display “WPS Enrollment in Progress”.
• Upon failure of enrollment, the LCD shall display “WPS Enrollment Failure”.
• Upon successful of enrollment, the LCD shall display “WPS Enrollment Success”.
NOTE: If you exit this section, all Wi-Fi sections are blocked until WPS is either
successful or has failed. The longest possible lock out is 1 minute.
NOTE: Communicator Option [663] must be 11, configured for Interactive over
Gateway. If this section is any other value, Wi-Fi sections are also blocked.
[921] WIFI422SCW Module Factory Default
Default (99)
Enter [00] to perform a factory default, this will disconnect the WiFi422SCW from the
Access Point. The installer must perform a WPS with the new Access Point in order to
enroll the router.
Once the Access Point is disconnected, the default SSID will display “X”.
(SCW Approval Label)
FCC COMPLIANCE STATEMENT
CAUTION: Changes or modifications not expressly approved by DSC could void your authority to use this
equipment.
This equipment generates and uses radio frequency energy and if not installed and used properly, in strict accordance with the manufacturer’s instructions, may cause interference to radio and television reception. It has been
type tested and found to comply with the limits for Class B device in accordance with the specifications in Subpart “B” of Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference in any
residential installation. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause interference to television or radio reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
• Re-orient the receiving antenna
• Relocate the alarm control with respect to the receiver
• Move the alarm control away from the receiver
• Connect the alarm control into a different outlet so that alarm control and receiver are on different circuits.
If necessary, the user should consult the dealer or an experienced radio/television technician for additional suggestions. The user may find the following booklet prepared by the FCC helpful: “How to Identify and Resolve
Radio/Television Interference Problems”. This booklet is available from the U.S. Government Printing Office,
Washington,D.C. 20402, Stock # 004-000-00345-4.
This device complies with Part 15 of the FCC Rules and with Industry Canada license exempt RSS standard(s).
Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2)
this device must accept any interference received, including interference that may cause undesired operation. “
“Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de
licence. L'exploitation est autorisée aux deux conditions suivantes: (1) l'appareil ne doipas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est
susceptible d'en compromettre le fonctionnement.
IMPORTANT NOTE: To comply with FCC and Industry Canada RF exposure compliance requirements,
the antenna used for this transmitter must be installed to provide a separation distance of at least 20
cm from all persons and must not be collocated or operating in conjunction with any other antenna or
transmitter. Failing to comply with any of the above conditions would require new FCC/IC equipment
authorization for the host device.
The WLAN module may only be used with host equipment (SCW905X control panels) as listed under
section "Compatibility".
© 2012 Tyco International Ltd. and its Respective Companies. All Rights Reserved.
Toronto, Canada • www.dsc.com
Tech Support: 1-800-387-3630 (Canada, USA), 905-760-3000
Printed in Canada
2 90 0 8 5 4 6 R0 0 1

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Author                          : tvecchiarelli
Create Date                     : 2012:12:12 09:37:26-05:00
Modify Date                     : 2012:12:18 09:36:51-05:00
Has XFA                         : No
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Producer                        : Acrobat Distiller 9.5.2 (Windows)
Creator Tool                    : PScript5.dll Version 5.2.2
Metadata Date                   : 2012:12:18 09:36:51-05:00
Format                          : application/pdf
Title                           : DRAFT_29008546R001_WIFI422SCW_INIS_ENG_ONLY.fm
Creator                         : tvecchiarelli
Document ID                     : uuid:ab3a7f8d-deda-4b8a-9709-496605f52f4d
Instance ID                     : uuid:e20e2754-adeb-4d9b-a345-d03651a6d2d2
Page Count                      : 1
EXIF Metadata provided by EXIF.tools
FCC ID Filing: F5312WIFI422SCW

Navigation menu