Dilon Technologies N29000 Wireless Receiver/Dongle User Manual User Service Manual

Dilon Technologies, Inc. Wireless Receiver/Dongle User Service Manual

User Service Manual

N2-5000-07-001 Rev 2  -1-  Revised 10/21/2015  www.Dilon.com     User/Service Manual    Manufactured by:  Authorized European Representative:  Dilon Technologies, Inc.  AG Medical    12050 Jefferson Avenue  Route de l'Orme,   Suite 340  Parc des Algorithmes  -  Imm. "Homère"   Newport News, VA 23606  91190 Saint-Aubin   USA  France   Phone: 1-844-DILONNAV  http://ag-medical.com/
Navigator 2.0 User Manual & Service Guide N2-5000-07-001 Rev 2  -2-  Revised 10/21/2015 Important Note All  personnel  that  will  interact  with  this  Navigator  2.0  System  and  Probes  should  read  this  Manual  and Service Guide to ensure proper use, handling, storage and maintenance.    This document and the information contained herein, is proprietary information of Dilon Technologies and may not be reproduced, copied in whole or in part, adapted, modified, disclosed to others, or disseminated without prior written consent of Dilon Technologies. This document is intended to be used by customers as part of their Dilon Technologies equipment purchase.   Dilon Technologies  provides this  document without warranty of  any kind, implied or expressed, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose.   Dilon Technologies  has taken care to ensure the accuracy of  this document. However, Dilon Technologies assumes no liability for errors or omissions, and reserves the right to make changes without further notice to  any  products  herein,  to  improve  reliability,  function,  or  design.  Dilon  Technologies  may  make improvements or changes in the products or programs described in this document at any time.  Navigator 2.0TM is a trademark of Dilon Technologies.  Other trademarks and trade names are those of their respective owners.   Copyright Notice Copyright 2015 Dilon Technologies, Newport News, VA 23606 United States of America.   Trademarks Dilon Technologies™ is a registered trademark of Dilon Technologies.   All other company and product names are trademarks or registered trademarks of their respective owners.   Part Number N2-5000-07-001 Rev 2 / October, 2015
Navigator 2.0 User Manual & Service Guide  N2-5000-07-001 Rev 2  -3-  Revised 10/21/2015  www.Dilon.com User Manual: Table of Contents 1. Introduction .......................................................................................................................................... 5 Description ............................................................................................................................................ 5 Intended Use ......................................................................................................................................... 5 Indications for Use ................................................................................................................................. 5 Manufacture and Distribution ................................................................................................................ 5 Trademarks ............................................................................................................................................ 5 Regulatory and Safety Requirements ..................................................................................................... 6 EC Directives .......................................................................................................................................... 6 Reciprocal Interference .......................................................................................................................... 6 Safety .................................................................................................................................................... 6 2. System Overview and Components ...................................................................................................... 9 3. Precautions ......................................................................................................................................... 10 3A. General .......................................................................................................................................... 10 3B. Control Unit, Battery, and Charger ................................................................................................. 10 3C. Probe ............................................................................................................................................. 10 4. Control Unit, Battery, Cables, and Co-Pilot ......................................................................................... 12 4A-1. Control Unit Features: Front ....................................................................................................... 12 4A-2. Control Unit Features: Back ........................................................................................................ 15 4B. Battery (Part # N2-8500-00) ........................................................................................................... 17 4C. Cables ............................................................................................................................................ 19 4D. Optional Co-Pilot™ Device (Part # GP-6801-00) .............................................................................. 20 4E. Useful Adjustments That Can Be Made During Procedures ............................................................. 22 5. Cleaning, Disinfection, and Sterile Use of Navigator Probes and Cables ............................................. 23 5A. Cleaning Probes ............................................................................................................................. 23 5B. Radioactive Decontamination Procedure – OPTIONAL.................................................................... 25 5C. Cleaning/Storing Control Unit & Gain Module ................................................................................ 25 6. Probe Connectivity and Use ................................................................................................................ 26 6A. Navigator 2.0 with Wireless Pilot Probe ......................................................................................... 26 6B. Navigator 2.0 with Standard Lymphatic Mapping Probes, Superficial Head & Neck Probe, Daniel Lung Probe, and Laparoscopic Probes .................................................................................................. 29 6C. Navigator 2.0 with 12mm Lymphatic Mapping Probe (Part # N2-9001-12)...................................... 31 7. Running the Peak Procedure: 12mm Lymphatic Mapping Probe Only ................................................ 33 7A. Running a Peak Procedure ............................................................................................................. 33
Navigator 2.0 User Manual & Service Guide  Service Manual  N2-5000-07-001 Rev 2  -4-  Revised 10/21/2015 8. Troubleshooting .................................................................................................................................. 35 9. Specifications ...................................................................................................................................... 37 9A. Navigator 2.0 System Specifications ............................................................................................... 37 9B. System Accuracy ............................................................................................................................ 38 10. Support Items ..................................................................................................................................... 39 10A. Product Part Numbers ................................................................................................................. 39 10B. Sterile Drape ................................................................................................................................ 39 11. Maintenance ....................................................................................................................................... 40 11A. Overview ..................................................................................................................................... 40 11B. Verification of Standard Gain (Calibration Quick Test) .................................................................. 40 11C. Fuse Replacement Procedure ....................................................................................................... 42 12. Repair.................................................................................................................................................. 44 13. Recycling ............................................................................................................................................. 45 14. Limited Warranty ................................................................................................................................ 46
Navigator 2.0 User Manual & Service Guide N2-5000-07-001 Rev 2  -5-  Revised 10/21/2015  www.Dilon.com USER MANUAL 1. Introduction Description The  Navigator  2.0  System  detects  gamma  photons,  such  as  those  produced  by  radioactive  decay.  The Navigator 2.0 System is a portable, battery powered system.  System use requires the Navigator 2.0 Control Unit, which allows the user to adjust the system's settings and produces a variety of signal outputs. The control unit is powered by battery.  The Control Unit is used with any of the following Navigator™ probe models. The probes differ primarily in their size, shape, detector technology and connection to the control unit.  • 14mm Wireless Pilot Probe™ (angled tip) • 14mm Standard Lymphatic Mapping Probes (angled tip & straight tip)  • 12 mm Lymphatic Mapping Probe (angled tip) • 11mm Superficial Head & Neck Probe (straight tip) • 10mm Daniel Lung Probe™ (straight tip) • 10mm Laparoscopic Probes (310mm & 190mm Lengths, straight tips)  The  system  is  supplied  non-sterile.  This  manual  includes  guidelines  for  the  use  of  the  probes  and accessories within the sterile field.  Intended Use For  the  detection  and  quantification  of  gamma  radiation  from  gamma-emitting  isotopes  in  the  body  or tissues. Use  for non-imaging procedures to measure  the amount of  radionuclide  absorbed by  a  particular organ or body region.  Indications for Use  For  the  detection  and  quantification  of  gamma  radiation  from  gamma-emitting  isotopes  in  the  body  or tissues. Use  for non-imaging procedures to measure  the amount of  radionuclide  absorbed by  a  particular organ or body region in open-surgical, laparoscopic or thoracoscopic surgical procedures.  Manufacture and Distribution  The system is manufactured and distributed by Dilon  Technologies of Newport  News,  VA. Please direct  all inquiries about the Navigator 2.0 to Dilon Technologies.  Trademarks The following are trademarks of Dilon Technologies: Navigator 2.0™, Wireless Pilot Probe™, Dilon Navigator GPS™,  Dilon  Navigator™,  Dilon  Technologies  Navigator  GPS™,  Dilon  Technologies  Navigator™,  Dilon Technologies Navigator 2.0™, Daniel Lung Probe™, and Navigator™ when used in context with the above.  Navigator GPS® is a registered trademark of Dilon Technologies.
Navigator 2.0 User Manual & Service Guide N2-5000-07-001 Rev 2  -6-  Revised 10/21/2015  Regulatory and Safety Requirements The  Dilon  Navigator  GPS™  System  including  Probes  and  accessories  complies  with  the  following standards:  EC Directives EMC Directive 89/336/EEC  Group l, Class B EN 55011 EMC Directive 89/336/EEC  IEC 60601-1-2: 3rd Edition  Reciprocal Interference This product has been tested and verified to ensure that there are no issues or concerns regarding reciprocal interference. This includes EMI, EMC and RF. This product has been certified and tested by 3rd party testing facilities. List of standards is as follows: •  Medical Electrical Equipment - Part 1: General requirements For Safety 1: Collateral Standard: Safety Requirements For Medical Electrical Systems – IEC 60601-1-1: 3rd Ed. •  Medical Electrical Equipment - Part 1: General Requirements For Safety - Collateral Standard: Electromagnetic Compatibility - Requirements and Tests – IEC 60601-1-2: 3rd Ed. Safety •  Medical Electrical Equipment - Part 1: General requirements For Safety 1: Collateral Standard: Safety Requirements For Medical Electrical Systems – IEC 60601-1: 2nd & 3rd Ed. •  Medical Electrical Equipment - Part 1: General Requirements For Safety - Collateral Standard: Electromagnetic Compatibility - Requirements and Tests – IEC 60601-1-2: 3rd Ed. •  Medical Electrical Equipment - Part 1-6: General Requirements For Safety - Collateral Standard: Usability - IEC 60601-1-6: 3rd Ed. •  Information supplied by the manufacturer of medical devices- EN 1041:2008 •  Symbols for use in the labeling of medical devices - EN 980 :2008 •  CAN/CSA C22.2 No. 60601-1, "Medical Electrical Equipment, Part 1: General Requirements for Safety & Essential Performance; issued 2008-02-01 Ed. 2 •  AS/NZS 3200-1-0, Deviations to IEC 601-1 for Application in Australia and New Zealand    CAUTION: Federal (USA) law restricts this device to sale and use by, or on the order of, a physician.
Navigator 2.0 User Manual & Service Guide N2-5000-07-001 Rev 2  -7-  Revised 10/21/2015 Table 1A. Explanation of Symbols   Type-CF Equipment   RX only Caution: Federal (USA) law restricts this device to sale and use by, or on the order of, a physician.   Probe   Date of Manufacture   Data Port   Manufactured by   Eject   or  Consult instructions for use   Attention, consult accompanying documents    Temperature limitation   Remote Count Control   Humidity limitation   Isotope Control   Serial number   Calibrate Control   Catalogue number   Fuse   European Authorized Representative   Battery   Batch code
Navigator 2.0 User Manual & Service Guide N2-5000-07-001 Rev 2  -8-  Revised 10/21/2015 Table 1A. Explanation of Symbols (Continued)  Battery Power Level  Caution: High Voltage   Acceptable shipping/storage conditions: -15° C to 40° C   WEEE Symbol (EU only)  FCC statements: “This device complies with part 15 of the FCC Rules.  Operation is subject to the following two conditions: (1) This device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation.”  IC statements: “This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) This device may not cause interference and (2) this device must accept any interference, including interference that may cause undesired operation of the device.”  Cet appareil est conforme avec Industrie Canada RSS exemptes de licence standard (s). Son fonctionnement est soumis aux deux conditions suivantes: (1) Ce dispositif ne doit pas causer d’interférences, et (2) cet appareil doit accepter toute interférence, y compris les interferences qui peuvent causer un mauvais fonctionnement de l’appareil.
Navigator 2.0 User Manual & Service Guide N2-5000-07-001 Rev 2  -9-  Revised 10/21/2015 2. System Overview and Components     Table 2A. Probe Dimensions Probe Tip Diameter Tip Angle Length Weight Wireless Pilot Probe 14mm 30 260mm 255g Standard Lymphatic Mapping Probes 14mm 14mm 0 35 224mm 220mm 185g 185g 12mm Lymphatic Mapping Probe 12mm 35 242mm 235 g Superficial Head & Neck Probe 11mm 0 207mm 161g Daniel Lung Probe™ 10mm 30 465mm 195g Laparoscopic Probes 10mm 10mm 0 0 467mm 347mm 195g 190g  Control Unit Battery 2-bay Battery Charger and Line Cord Wireless Pilot ProbeBatteryNavigator 2.0 Control Unit 10 mm Daniel Lung Probe14 mm Wireless Pilot Probe14 mm Standard Sentinel Node Mapping Probe  11 mm Superficial Head & Neck Probe  10 mm Laparoscopic Probe (310 mm long)
Navigator 2.0 User Manual & Service Guide N2-5000-07-001 Rev 2  -10-  Revised 10/21/2015 3. Precautions 3A. General • The output of this system is not to be considered a diagnostic measure of the extent of disease in the patient, nor the recommended source of therapy.  • Failure  to  thoroughly  review  and  adhere  to  the  information  contained  in  this  User  and  Service Manual may pose a potential hazard to the patient and/or user and may void the warranty.  3B. Control Unit, Battery, and Charger • During system use, maintain electrical isolation of the patient. Do not connect the probe, cable (if used), or the internal circuit of the control unit to earth ground, or to other voltage potentials.  • Maintain patient electrical isolation. Do not defeat the electrical isolation of the surface of a probe cable  (if  used),  and  the  control  unit  housing.  These  isolate  the  battery-power  circuit  inside  the control unit, the conductors inside the probe cable, the probe surface, and the patient.  • When optional system components are used with the system, maintain probe and patient electrical isolation  from  earth  ground.  The  optional  components  include  the  Co-Pilot™  Device,  the  probe drape, the Top Gun™ Collimator, and Navigator 2.0 cart.  • In  the  operating  room,  use  the  charger  at  a  distance  of  six  feet  or greater  from  the  patient.  The charger has a rating in the United States of a "patient proximity charger.”  • Fully charge the battery before use in the system.  • Replace the wireless probe battery with a new battery on EACH day of use, before the first surgical procedure.  • This system is not designed for use in an explosive atmosphere.  • Keep  the  control  unit off when  changing  connections  between  the  probe,  cable,  control  unit  and gain module, when used. Control unit should also be off when inserting battery into Wireless Pilot Probe. • The control unit, cables, batteries, charger, and probes are sold non-sterile.  3C. Probe • DO NOT put any probe or probe cable in an autoclave. • With the exception of the Wireless Pilot Probe’s battery bay, DO NOT attempt to open probes. o All probes are tested and sealed at the factory. Attempting to open the probe may cause damage and will void the warranty.  • Remove probe battery before cleaning Wireless Pilot Probe.  • DO NOT drop the probe. • DO NOT strike the probe tip against a hard surface; the detector element may become damaged and no longer be able to measure radiation. o This will also void the warranty. • When using the 12mm probe, DO NOT place it on, or near, a magnetic instrument pad. 3C-1. Laparoscopic and Thoracoscopic Probe Use  • This  User/Service  manual  is  designed  to  assist  the  use  of  the  Navigator  2.0  system  and  is  not  a reference  to  surgical  techniques.  For  information  on  endoscopic  procedures,  techniques, complications and hazards, please reference the following publications: Surgical Laparoscopy (Zuker KA ed. St. Louis MO 1991) and Endoscopic Surgery (White RA Klein SR, Mosby Year Book Inc. St Louis MO  1991).    • This  device  is  intended  for  use  only  as  indicated.  It  is  not  intended  for  use  when  endoscopic
Navigator 2.0 User Manual & Service Guide N2-5000-07-001 Rev 2  -11-  Revised 10/21/2015 techniques  are  generally  contraindicated.  Please  reference  Textbook  of  Laparoscopy  (Hulka  JF. Grunda  and  Stratton,  Inc.  Orlando  FL  1985  op114-116)  for  information  on  absolute contraindications, high-risk patients and low-risk patients.  • The  use  of  the  Navigator  2.0  system  with  laparoscopy  should  only  be  attempted  where  there  is adequate visualization of the target tissue.  • Trocars should be placed in accordance with standard laparoscopic and  thoracoscopic techniques, with  specific  regard  to  target  organ  geometry  to  assure  probe  access  to  the  target  organ.  Please reference  current  trocar  labeling,  suggesting  working  knowledge  of  laparoscopic  techniques  and familiarization with trocar placements under direct visualization through a laparoscope.    CAUTION: Endoscopic procedures should be performed only by physicians with adequate training and familiarity with endoscopic techniques. Medical literature should be consulted relative to techniques, complications, and hazards, prior to the performance of endoscopic procedures.
Navigator 2.0 User Manual & Service Guide N2-5000-07-001 Rev 2  -12-  Revised 10/21/2015 4. Control Unit, Battery, Cables, and Co-Pilot 4A-1. Control Unit Features: Front    The control unit contains the display, the battery, and most of the system controls. These system controls are located on the front and back of the control unit.  The control unit allows the user to adjust the system’s settings and produces signal outputs in the form of a count  rate, viewable  in  the  display, as  well  as an  audible  pitch that  represents  the  intensity  of  a probe’s signal.  The number of gamma photons (called “events”) shown in the control unit display is determined primarily by a probe and the probe’s position (with respect to the radioactively-tagged tissue), and secondarily by the position of the controls on the control unit.   Count Display 10-second Count Button and Indicator Calibration –Check Mode Indicator Range Button and Indicators Volume Knob Isotope Indicators Signal Input (Cable Port) Co-Pilot Receptacle Threshold Control Power Button Battery Charge Status
Navigator 2.0 User Manual & Service Guide N2-5000-07-001 Rev 2  -13-  Revised 10/21/2015 Table 4A-1. Controls and Displays on the Front of the Control Unit Control Display  Description  Power button: Turns power on and off.  Volume knob: Increases/decreases the volume of the audible signal.  Display Screen: When turned on, displays the photon count per second. Upon completion of a 10-second count, the total number of photons detected will show on the display screen for 4 seconds, and then the display returns to showing counts per second.  Isotope Indicator: Indicates the isotope selected. Isotopes detected on the Navigator 2.0 are I125, 511keV (for I-131 or FDG-18), In111, and Tc99.   Range Settings: Adjusts the audible pitch, based on density of events detected: 1x – Low event rates; all events are heard. 10x – Medium event rates; 1 in 10 events are heard. 100x – High event rates; 1 in 100 events are heard. Pressing the Range button cycles through the ranges; Select the one most useful to the procedure being performed. NOTE: Range selection only controls pitch of the sound generated by the unit; it has no effect on count rates displayed or signal conditioning.  Threshold: For CABLED PROBES only, it controls the count range of photon energy detected by the probe. When the Threshold is off, the indicator is not illuminated, and all photon energy, including scattered photons, is detected.  When the Threshold is on, the indicator is illuminated. In this setting, the detection of scattered photons is reduced or eliminated. Signals of amplitude outside the pre-configured energy range are discarded. Only those events within the particular energy range are counted and displayed.  NOTE: The Threshold is normally on when using probes. The Threshold may be set to off to count all events detected by a cabled probe. (The Wireless Pilot Probe features integrated threshold)
Navigator 2.0 User Manual & Service Guide N2-5000-07-001 Rev 2  -14-  Revised 10/21/2015 Control Display  Description  Count: Initiates a 10-second photon count. When Count has been pressed, the count indicator on the display screen is illuminated and the display screen will show increasing counts. Probe must be held in a fixed position for entire duration of 10-second count. When the 10 seconds are complete, the control unit beeps, and the total count is shown in the display. After displaying the total count for four seconds, the display goes back to showing counts per second.  Cal-check: This light indicates when the system is in ‘Calibration-Check’ mode on the back of the unit. The light will be illuminated when in any of the 3 calibration-check settings, and will not be illuminated when the system is set to the ‘Scan’ mode.  The SCAN / Calibrate Control must be set to the SCAN position only, for all probes for all procedures. In this mode, the ‘Cal’ light will be turned off. See “Verification of Standard Gain (Calibration Quick Test)” in Section 11B for more information on Calibration.  The Battery indicator shows the charge status of the battery in use. When the indicator level on the control unit is at 25%, the battery should be replaced immediately with a fully-charged battery. Please note that the charge status on the control unit may differ from charge status reflected on the battery, due to a higher power requirement on the control unit. Refer to charge status on control unit rather than the battery itself.  Signal input port, for cable connection. The signal input port is not applicable when using the Wireless Pilot Probe with the Navigator 2.0.  For the 12mm Lymphatic Mapping Probe, connect the cable attached to the Gain Module here, matching the arrows on the cable connector to the arrow above the signal input port. See “3mm Diameter Cable” in Section 4C for more information. For all other cabled probes, connect the probe cable here, matching the arrow on the cable connector to the arrow above the signal input port. See “6mm Diameter Cable” in Section 4C for more information.  Connection port for the optional Co-Pilot accessory. See “Optional Co-Pilot Device” in Section 4D for more information.
Navigator 2.0 User Manual & Service Guide N2-5000-07-001 Rev 2  -15-  Revised 10/21/2015 4A-2. Control Unit Features: Back             Integrated Handle Scan/Cal-checkControl  Isotope Control Battery  Compartment Door Fuse HolderPole Mount Connection
Navigator 2.0 User Manual & Service Guide N2-5000-07-001 Rev 2  -16-  Revised 10/21/2015 Table 4A-2. Controls and Displays on the Back of the Control Unit Control Display  Description  For CABLED PROBES only. The SCAN position is the only correct position when a probe is being used during a procedure. When set to SCAN, the CAL indicator on the front of the control unit will not illuminate. For instructions on use of the ‘+’, ‘0’, and ‘-‘positions, see “Verification of Standard Gain (Calibration Quick Test)” in Section 11B.  Selects the isotope to be detected by the control unit.    SCAN/Calibrate Control  For CABLED PROBES only. The SCAN/Calibrate Control has FOUR POSITIONS. During all surgical procedures, this control should be in the SCAN Position. During the calibration verification procedure, this control uses the remaining three settings, “+”, “0”, and “-”.  NOTE:  See  “Verification  of  Standard  Gain  (Calibration  Quick  Test)”  in  Section  11B  for  information  on calibration verification. NOTE: If the front panel CAL indicator is flashing before a procedure, move the control to the SCAN position.   Isotope Control The Isotope Controls allow the user to designate the specific isotope in use.  Switch set on: I125  Switch set on: 511keV  Switch set on: In111  Switch set on: Tc99 Iodine-125 18F-FDG (and I131)  Indium111 Technetium-99m  The  Isotope  Control  setting  on  the  back  of  the  control  unit  illuminates  the  corresponding  light  on  the Isotope Indicator on the front of the control unit.    CAUTION:  It  is  important  that  the  isotope  control  is  set  to  the  isotope  that  is  going  to  be  used  in  the procedure. Setting the isotope control incorrectly will result in incorrect detection.
Navigator 2.0 User Manual & Service Guide N2-5000-07-001 Rev 2  -17-  Revised 10/21/2015 4B. Battery (Part # N2-8500-00) 4B-1. Inserting the Battery Open the door to the battery port, located on the right side of the control unit. Insert a fully charged battery with the battery label facing toward the rear of the  unit, with battery contacts inward and  tab on side  of battery positioned outward. Use direction indicator arrow on battery label for guidance.  Shut the door of the battery port. The door will “click” when closed properly.  4B-2. Removing the Battery Open the door to the battery port, located on the right side of the control unit. To remove the battery, pull the tab attached to the end of the battery.
Navigator 2.0 User Manual & Service Guide N2-5000-07-001 Rev 2  -18-  Revised 10/21/2015 4B-3. Charging the Battery (Battery Charger Part # N2-8000-02) Place the charger on a flat, level surface, away from sources of heat and moisture. Plug the DC connector from the power supply into the back of the charger, and connect the power supply to the mains AC, using the cable supplied. All of the LEDs will flash momentarily to indicate that power is present.   Recharge Time: Approximately 3.5 hours  Place  the  battery  into  either  battery  bay,  ensuring  that  the  5-way  connector  is  fully  seated.  The  battery should feel secure once inserted correctly. The LEDs in the battery status window will provide charge status, and  the  charger  will  automatically  begin  charging.  Each  charge  bay  operates  independently,  providing simultaneous charge of each battery inserted.  While there is a calibration button for each bay, calibration is not necessary for use with the Navigator 2.0. If calibration button is inadvertently pressed, either a flashing blue or solid blue light will illuminate. Simply remove battery and reinsert in order to resume charge. A green light will indicate that it is in charge mode. If  charger  has  flashing  red light, the  battery  fuel  gauge  requires  calibration.  Only  in  this  case,  should  the calibration button be pressed. Recalibration can take 10-13 hours. If charger lights solid red, please refer to troubleshooting guide.  Table 4B-4. Charge Bay LED Indications Indication Battery Charge Status Green Flashing  Battery Charging Green Solid  Battery Fully Charged Blue Flashing or Solid   Calibration mode: UNNECESSARY. Do not use. Red Flashing   Battery fuel gauge in need of calibration  Red Solid  Error  NOTE:   Use only batteries supplied by Dilon Technologies. The Dilon Technologies control unit battery has the proper dimensions and a key feature that holds it securely in the Navigator 2.0 control unit.   NOTE:   Approximately 3.5 hours are required to charge a completely drained battery. Having a second, fully charged battery available while the first battery is in use, is recommended.  DC Connector Battery Bays Calibration buttons Status window
Navigator 2.0 User Manual & Service Guide N2-5000-07-001 Rev 2  -19-  Revised 10/21/2015  CAUTION:  Do not expose the charger or power supply to water or liquids; the case is not sealed. Do not open the charger or power supply case; no user-serviceable parts are inside. Do not cover the fan exhaust or obstruct the airflow; this will cause overheating.  Place the charger in a cool spot, away from external heat sources.  4C. Cables  In addition to the Wireless Pilot Probe, the Navigator 2.0 may also be used with cabled probes. One of the following two cables is used, depending on the wired probe selected.  4C-1. 3mm Diameter Cable (Part # PM-4000-20) and Gain Module (Part # PM-0400-40) The  12mm  Lymphatic  Mapping  Probe  uses  a  cable  that  has  two  conductors  and  an  outside  diameter  of approximately  3mm.  It  also  uses  a  Gain  Module  (pictured  below), which connects  the control  unit to  the probe cable.  1. Connect the 3mm Diameter Cable to the probe, matching the red indicator dot on the probe to the red indicator dot on the cable.  2. Connect the other end of the 3mm Diameter Cable to the gain module, matching the red indicator dot on the cable to the gain module’s cable input port.  3. Connect  the  gain  module  to  the  control  unit,  matching  the  arrows  on  the  gain  module  cable connector to the arrow above the signal input port. The gain module connector will “click” when it is seated properly.
Navigator 2.0 User Manual & Service Guide N2-5000-07-001 Rev 2  -20-  Revised 10/21/2015 The connector has a locking mechanism. To disconnect the cable from the probe and from the gain module, pull directly back on the hood; DO NOT pull or twist the connector jacket.   4C-2. 6mm Diameter Cable (Part # GP-4001-00)  A different cable is used for the standard lymphatic mapping probes (straight or angled), Superficial Head & Neck  Probe,  laparoscopic  probes,  and  the  Daniel™  Lung  Probe.  This  cable  has  five  receptacles  inside  the probe end, and seven pins inside the plug, that connect to the control unit. The cable is approximately 6mm in diameter.  Connect the cable to the control unit, matching the arrows on the cable connector to the arrow above the signal input port.    The connector is a locking connector. To disconnect the cable from the probe and from the control unit, pull directly back on the hood; DO NOT pull or twist on the jacket. WARNING! Do not pull or twist the jacket of the cable, to remove from control unit. You must pull on the hood  at the end of  the cable. Pulling or twisting the jacket may damage the cable and render it unusable.  4D. Optional Co-Pilot™ Device (Part # GP-6801-00) The optional  Co-Pilot  is  a  single-use device  used for  initiating  counting  periods  and adjusting  the  audible range from the probe, inside the sterile field. It includes two small buttons, and a long, small-diameter cable.  To plug in the Co-Pilot, match the spacing of the prongs with the spacing of the receptacles on the control unit. It should then be clipped onto the base of the probe.  The Co-Pilot is supplied sterile and may be used inside or outside of the sterile drape.
Navigator 2.0 User Manual & Service Guide N2-5000-07-001 Rev 2  -21-  Revised 10/21/2015       The “C” button is the COUNT Button. Obtain a one-second count by pushing and releasing this button once. Obtain a  ten-second  count by  pushing  this  button  twice, in  quick  succession.  Each  time,  total  counts  are shown in the display screen on the control unit.  The  “R”  button  is  the  RANGE  Button.  This  button  operates  the  Range  control  mentioned  above  on  the control  unit.  Push  and  release  the  RANGE  Button  to  select  an  audible  range,  appropriate  to  the  signal detected by the system.    CAUTION:  The  Co-Pilot  can  only  be  attached  to  the  control  unit  one  way  –  the  prongs  are  not  evenly spaced (see image below).   C Button (Count) R Button (Range)
Navigator 2.0 User Manual & Service Guide N2-5000-07-001 Rev 2  -22-  Revised 10/21/2015 4E. Useful Adjustments That Can Be Made During Procedures   Table 4D-1. Useful Adjustments  Adjustment Benefit Threshold For Cabled Probes only, this feature increases specificity when only a low number of events are observed. Threshold control defaults to ON. When ON, the system counts only the events in a narrow energy range around the signal. Change Threshold to OFF to allow the system to count all signals it detects, opening the value range to scatter. (NOTE: The Wireless Pilot Probe features integrated threshold.) Range The Range function defaults to 1X, meaning that the audible signal fluctuates according to every single count it detects. In the 10X position, every 10th event produces an audible output. In 100X, only every 100th event produces an audible output. The Range control only affects the sound. The count shown in the display is independent of the range setting. 10-Second Count Press to obtain a 10-second count, keeping probe in fixed position each time. The total is displayed for at least four seconds, allowing time to record the total. Volume Adjust to desired volume. Power  Press to turn on the control unit or to safely turn off the device.  10-second Count Button and Indicator Range Button and Indicators Volume Knob Threshold Control Power Button
Navigator 2.0 User Manual & Service Guide N2-5000-07-001 Rev 2  -23-  Revised 10/21/2015 5. Cleaning, Disinfection, and Sterile Use of Navigator Probes and Cables All probes and probe cables require cleaning and disinfecting immediately after use. Follow these steps to ensure that cleaning and disinfection are done correctly. • Before Use, visually inspect probe and probe cable to ensure that it is free of contamination. • Place probe and cable in a sterile drape while in use. • After Use, Clean/Disinfect/Store Probe and Probe Cable. • Radioactive Decontamination Procedure – OPTIONAL (see section 5C).  CAUTION:  All Dilon probes and probe cables must be used inside a sterile drape. The control unit, gain module (if used), and battery/charger are used outside of the sterile field. Probes and probe cables should be cleaned and disinfected separately from the other components. 5A. Cleaning Probes • Visually inspect the probe and cable for contamination before storing. If the probe or cable show visual signs  of  contamination,  or  may  possibly  be  contaminated,  then  proceed  to  Table  5A-1,  “Cleaning  & Disinfection”.  WARNING!  Do not scratch or abrade the probe when decontaminating. Scratching / abrading the probe will make future decontamination difficult, if not impossible. Table 5A-1. Cleaning & Disinfection Preparation for cleaning: Remove battery from Wireless Pilot Probe, and secure battery cap to the bottom of probe before cleaning.  Cleaning Equipment: Enzymatic detergent, OPA high-level disinfectant, running water Cleaning Method: 1. Rinse  the  outside surfaces of the  probe  with  a brisk  stream  of  lukewarm tap  water (98°F to 105°F / 36.5°C to 40.5°C). Prepare enzymatic cleaner, suitable for surgical instruments, according to the manufacturer's recommendation. Wipe with soft cloth or sponge  soaked  in enzymatic  cleaner. Repeat separately  for collimator cleaning, if used.  2. Visually inspect device(s) for contaminated areas. 3. Repeat steps 1 & 2 until visual inspection reveals instrument(s) is clean.  4. Rinse equipment with a brisk stream of lukewarm tap water (98°F to 105°F / 36.5°C to 40.5°C) for 30-seconds.    Disinfection: 1. Prepare Mixture according to manufacturer’s instructions 2. Immerse probe  and  cable completely  for a  minimum of  12  minutes at  68°F (20°C or higher), to destroy all pathogenic microorganisms.  • Note that probes that are compromised can be damaged if detergent seeps into them. 3. Rinse equipment with a brisk stream of lukewarm tap water (98°F to 105°F / 36.5°C to 40.5°C) for approximately1 minute. Repeat rinse two additional times.  Drying: Air-dry  or  dry  with  clean  towel. Flush  the  probe  connector  with  70%  isopropyl  or  ethyl alcohol, and then flush with air. Ensure that the connector ends of the probe and cable are completely dry before storing.
Navigator 2.0 User Manual & Service Guide N2-5000-07-001 Rev 2  -24-  Revised 10/21/2015
Navigator 2.0 User Manual & Service Guide N2-5000-07-001 Rev 2  -25-  Revised 10/21/2015  5B. Radioactive Decontamination Procedure – OPTIONAL  An increase in background counts may signal radioactive contamination of the probe or the environment. If a process of elimination shows the probe to be contaminated with radioactive material, the probe must be decontaminated.  1. Decontaminate the probe using standard Nuclear Medicine Department techniques, which may involve washing the probe with a solution such as Radiacwash™. 2. Ensure that all recesses, crevices, and mating surfaces are clean. 3. Dispose of pads and cleaning solution in approved containers.   5C. Cleaning/Storing Control Unit & Gain Module  1. If unclean, wipe control unit and gain module (if present) with a soft cloth moistened with mild soap and water. Dry with a soft cloth.  2. Store the control unit and gain module in a clean, safe environment.   CAUTION:  Follow universal, generally accepted practices when handling components that have come in contact with blood or tissue.
Navigator 2.0 User Manual & Service Guide N2-5000-07-001 Rev 2  -26-  Revised 10/21/2015 6. Probe Connectivity and Use 6A. Navigator 2.0 with Wireless Pilot Probe   The Wireless Pilot Probe is used in various procedures. A typical sequence of setting up the Wireless Pilot Probe  for  a  procedure  with  a  Technetium-99m  isotope  (such  that  may  be  used  in  a  lymphatic  mapping procedure for a sentinel node biopsy) is as follows:   6A-1. Before Surgery  • Insert a charged battery into control unit (see Section 4B-1).  • Upon initial insertion of new Wireless Pilot Probe battery, probe may need to be lightly shaken to activate LED in probe base. • LED on the Pilot Probe indicates that it is linked with control unit and ready for use. When placed in a resting position, the LED turns off within seconds, to save energy. When the Pilot Probe is moved, it instantly powers up for immediate use. • For intraoperative use, insert the Wireless Pilot Probe into a sterile drape. • Insert a probe battery into the Pilot Probe as follows:  1. Hold  probe  firm;  turn  battery  cap  counterclockwise  and  remove  from  probe.  Inspect  O-ring integrity. If O-ring is missing or damaged, use new battery cap. Contact Dilon Technologies or your distributor for battery cap reorder information.
Navigator 2.0 User Manual & Service Guide N2-5000-07-001 Rev 2  -27-  Revised 10/21/2015  2. Install 3V CR 2 lithium battery in Pilot Probe battery holder with positive (+) end facing toward the  base  of  the  probe  and  negative  (-)  end  toward  the  middle  of  the  probe.  Incorrect placement  of  battery  into  battery  holder  for  extended  periods  of  time  will  cause  battery  to drain quickly.  3. Insert battery holder into probe negative (-) end in. Lightly turn until holder lowers into place.   4. Hold probe firm; push battery cap into probe and turn clockwise until O-ring is no longer visible.
Navigator 2.0 User Manual & Service Guide N2-5000-07-001 Rev 2  -28-  Revised 10/21/2015 Table 6A-1. Pilot Probe LED Indicator Indication Status On/Flashing  Probe is linked and ready for use.   Off Probe is in a resting position to conserve power; to reactivate LED indicator, simply pick up probe, or if needed, lightly shake probe.  If no power upon ready to use, the battery needs to be installed or replaced.  If battery has been replaced and LED light is still off, contact your distributor or Dilon Technologies directly.  6A-2. During Surgery  • See ‘Useful Adjustments that can be made During Procedures’ (Section 4E). NOTE:   For Technetium-99m (Tc99), the control unit settings are given in the following table.  NOTE:   Follow the instructions in the section on ‘Cleaning, Disinfection, and Sterile Use of Probe’ (Section 5). Table 6A-2. Navigator 2.0 with Wireless Pilot Probe – Settings & Indicators (just prior to surgery) Control / Indicator Setting Controls (back of Control Unit)  SCAN/Calibrate: SCAN Isotope: Tc99 Indicators (front of the Control Unit)  Range: 1x  Threshold: Illuminated Display: 0  Isotope: Tc99 Indicator (top of the Pilot Probe handle)  Probe LED: Illuminated; flashing.  6A-3. After Surgery  • See: ‘Cleaning, Disinfection, and Sterile Use of Navigator Probes & Cables’ (Section 5).
Navigator 2.0 User Manual & Service Guide N2-5000-07-001 Rev 2  -29-  Revised 10/21/2015 6B.  Navigator  2.0  with  Standard  Lymphatic  Mapping  Probes,  Superficial  Head  &  Neck  Probe, Daniel Lung Probe, and Laparoscopic Probes Standard Lymphatic Mapping Probe:   SP-2A14-67 (Angled)  SP-2S14-67 (Straight) Superficial Head & Neck Probe:  SP-2S11-53 Daniel Lung Probe:  SP-2S10-31D Laparoscopic Probe:  SP-2S10-31 (310 mm shaft)  SP-1S10-19 (190 mm shaft)   These Navigator probes are used in various procedures. A typical sequence of setting up these probes for procedures with a Technetium-99m isotope (such as may be used in a lymphatic mapping procedure for a sentinel node biopsy, localization of a parathyroid adenoma, or localization of a sub-centimeter lung nodule) is as follows:   6B-1. Before Surgery  • See: ‘Cleaning, Disinfection, and Sterile Use of Probes and Cables’ (Section 5). • Insert a fully charged battery into control unit (Section 4B-3). • Connect the probe and cable to control unit (Section 4C-2). • For intraoperative use, insert probe and cable in a sterile drape.
Navigator 2.0 User Manual & Service Guide N2-5000-07-001 Rev 2  -30-  Revised 10/21/2015 Table  6B-1.  Navigator  2.0  with  Standard  Lymphatic  Mapping  Probes,  Superficial  Head  &  Neck  Probe, Daniel Lung Probe, and Laparoscopic Probes - Settings and Indicators (just prior to surgery) Control/Indicator Setting (with Tc99 example) Controls (back of Control Unit) SCAN/Calibrate: SCAN Isotope: Tc99 Indicators (front of the Control Unit) Range: 1x  Threshold: Illuminated Display: 0 Isotope: Tc99  6B-2. During Surgery  • See ‘Useful Adjustments that can be made During Procedures’ (Section 4E).  • See ‘Optional Co-Pilot Device’ (Section 4D).  6B-3. After Surgery  • See: ‘Cleaning, Disinfection, and Sterile Use of Probes and Cables’ (Section 5).   NOTE:   The time to charge a battery by the charger may take as long as 3.5 hours. NOTE:   Keep  control unit powered off until all components are  connected. This helps preserve component life.  Cautions for Thoracoscopic, Laparoscopic, and Endoscopic Procedures:   CAUTION:  Trocars  should  be  placed  in  accordance  with  standard  laparoscopic  and  thoracoscopic techniques, with specific regard to target organ geometry to assure probe access to the target organ. Please reference current trocar labeling suggesting working knowledge of laparoscopic techniques  and  familiarization  with  trocar  placements  under  direct  visualization  through  a laparoscope.    CAUTION:  Endoscopic procedures should be performed only by physicians having adequate training and familiarity  with  endoscopic  techniques.  In  addition,  medical  literature  should  be  consulted relative  to  techniques,  complications  and  hazards,  prior  to  the  performance  of  endoscopic procedures.
Navigator 2.0 User Manual & Service Guide N2-5000-07-001 Rev 2  -31-  Revised 10/21/2015  6C. Navigator 2.0 with 12mm Lymphatic Mapping Probe (Part # N2-9001-12)  The Navigator 12mm lymphatic mapping probe is used in various lymphatic mapping procedures. Please note that the system pictured above also includes battery and charger.  6C-1. Before Surgery • Charge and insert the battery into control unit (Section 4B-3).  • Connect the probe, cable, and gain module to control unit (Section 4C-1). • Run a Peak Procedure (Section 7A).   Navigator 2.0 Control Unit Gain Module Cable for 12 mm Lymphatic Mapping Probe 12 mm Lymphatic Mapping Probe
Navigator 2.0 User Manual & Service Guide N2-5000-07-001 Rev 2  -32-  Revised 10/21/2015 Table 6C-1. Navigator 12 mm Probe - Settings and Indicators for use with Tc99 (just prior to surgery) Control/Indicator Setting Controls (back of Control Unit) SCAN/Calibrate: SCAN Isotope: Tc99 Indicators (front of the Control Unit) Range: 1x  Threshold: Illuminated Display: 0 Isotope: Tc99 Gain Module Dial at Peak Setting: Perform peak procedure (See Section 7A)  NOTE:   Keep control unit power off, until all components are connected.  NOTE:   A ‘peak procedure’ must be performed before using the probe in the first surgical procedure of the day (see Section 7A).  NOTE:   Although the ‘peak procedure’ is  typically performed with  no sterile drape around the probe and cable, it may also be performed with the probe and cable inside a sterile drape.  NOTE:   After a ‘peak procedure’ has been performed, the control unit and gain module settings are given in the table above.  NOTE:   Follow the instructions in Section 5 on ‘Cleaning, Disinfection, and Sterile Use of Probe and Cable’.  CAUTION:  For intraoperative use, insert probe and cable in a sterile drape.   6C-2. During Surgery  • See ‘Useful Adjustments that can be made During Procedures’ (Section 4E).  6C-3. After Surgery  • See: ‘Cleaning, Disinfection, and Sterile Use of Probes and Probe Cables’ (Section 5).
Navigator 2.0 User Manual & Service Guide N2-5000-07-001 Rev 2  -33-  Revised 10/21/2015 7. Running the Peak Procedure: 12mm Lymphatic Mapping Probe Only It is important to note that the 12mm Lymphatic Mapping Probe DOES NOT use the ‘Calibration Verification Quick Test’ referenced later in section 11B – instead, the probe-control unit configuration is brought to its highest sensitivity point via the ‘Peak Procedure,’ described below. 7A. Running a Peak Procedure  A Peak Procedure finds the best “sensitivity” of a probe when “paired” with a control unit. The setting on the gain module at which the probe counts the most events.  Adjusting the gain module dial increases/decreases the count rate in the Navigator 2.0 Display. Starting with the control unit turned on and the dial in the full counter-clockwise position (0), the location on the gain module dial where the count rate reaches its maximum value is called the Peak Setting. The system should then be left in this setting for any subsequent procedures that day. The probe must be held in a fixed position with respect to an isotope source during a Peak Procedure. This source  can  be  either  a  check  source  or  the  injection  site  (or  some  other  region  of  high  activity)  of  the patient.  Only the Navigator 12mm Lymphatic Mapping Probe requires a Peak Procedure, because it is the only probe that uses the gain module. The Peak Procedure should be performed on EACH day of use, before the first surgical procedure.    Above: Example of a Peak Procedure using a Cobalt-57 check source
Navigator 2.0 User Manual & Service Guide N2-5000-07-001 Rev 2  -34-  Revised 10/21/2015 Table 7A-1. Example: Using and “pairing” multiple 12mm Sentinel Node Mapping Probes during one surgical day with the same control unit 1. Probe A is going to be used on Monday for all surgical procedures scheduled on that day. 2. Peak Procedure is run on Probe A before the first surgical procedure of that day. 3. Probe A counts are highest when the Gain Module dial is set to about 4.5. The dial is left at that location. 4. Probe A is ready for all surgical cases for the day. 5. Probe A is dropped and damaged. It cannot be used again until tested and/or repaired.  6. The  Surgical  Team  chooses  to  use  Probe  B  for  the  rest  of  the  case  and  for  all  others scheduled on that day. 7. A  Peak  Procedure  is  run  on  Probe  B  before  the  next  case  or  before  continuing  the current surgical procedure to “pair” it with the control unit.  8. Probe B counts are highest when the Gain Module dial is set just above 6. The dial is left at that location.  9. Probe B is ready for all surgical cases for the day.
Navigator 2.0 User Manual & Service Guide N2-5000-07-001 Rev 2  -35-  Revised 10/21/2015 SERVICE MANUAL 8. Troubleshooting With  the  exception  of  the  Wireless  Pilot  Probe’s  battery  holder,  no  serviceable  components  are  located inside the control unit or probes. Contact your representative or Dilon Technologies for additional assistance if more detail is required.  Table 8A-1. Control Unit Only - Settings and Indicators  Problem  Possible Causes  Remedies 1. Display is dark; No power to unit. Power switch is off;  Switch is broken. Unit may have been dropped. Turn power on;  Contact Dilon Technologies for assistance. Battery is dead. Recharge battery, or replace with new battery. Fuse is blown or missing. Replace fuse. Damaged PCB (board) in control unit Contact Dilon Technologies for assistance. 2. Incomplete digits in display. Display, or display driver, is damaged.  Unit may have been dropped. Contact Dilon Technologies for assistance.  Table 8A-2. Navigator 2.0 Control Unit with WIRELESS PILOT PROBE- Settings and Indicators  Problem  Possible Causes  Remedies 1. Zero in display. No signal under presence of a radioactive source. No wireless connection between probe and control unit. Replace the probe battery. Verify that battery was inserted correctly into probe (‘+’ should face toward base of probe). Isotope control is set to incorrect isotope. Change isotope control (on back of control unit) to Tc-99. Circuit inside the control unit has been damaged. Try a different control unit. Contact Dilon Technologies for assistance. Probe LED is illuminated but not transmitting signal to unit (LED flashes when transmitting). Gently shake probe to activate connectivity. Probe is damaged / probe cap not secure. Try a different probe, or contact Dilon Technologies for assistance.
Navigator 2.0 User Manual & Service Guide N2-5000-07-001 Rev 2  -36-  Revised 10/21/2015 Problem  Possible Causes  Remedies 2. LED on Pilot Probe does not illuminate. Probe battery is dead or installed incorrectly. Replace with new battery. Verify that battery was inserted correctly into probe (‘+’ should face toward base of probe). Battery was not installed. Install new battery. LED on probe is damaged. Contact Dilon Technologies for assistance.  Table 8A-3. Control Unit with CABLED PROBE- Settings and Indicators  Problem  Possible Causes  Remedies 1. Zero in display. No signal under presence of a radioactive source. No connection between probe, cable, gain module (if present), and control unit. Check that all connections are secure. Isotope control is set to incorrect isotope. Change Isotope Control (on back of control unit) to Tc-99. Gain module, if used, is set to zero. Run Peak Procedure (Sec. 7A). There is an open circuit in the probe cable. Replace cable. Circuit inside the control unit has been damaged. Try a different control unit. Contact Dilon Technologies for assistance. Probe is damaged / probe cap not secure / detector damaged. Try a different probe or contact Dilon Technologies for assistance. 2. Spurious high counts, such as 80,000 counts a second (when probe is held in air, for example). Intermittent short in the cable. Replace cable.
Navigator 2.0 User Manual & Service Guide N2-5000-07-001 Rev 2  -37-  Revised 10/21/2015 9. Specifications 9A. Navigator 2.0 System Specifications The Navigator 2.0 system consists of the control unit, one or more probes, and the system accessories.  Table 9A-1. Navigator 2.0 System Specifications Item Description Control Unit Power Source Replaceable, internal battery Battery Rechargeable Smart Lithium Ion Battery; 10.8V (nominal) voltage, 8.7Ah (nominal) capacity, 94Wh SOC (state-of-charge) indicator. Approximate weight: 470g New Battery Charge Life – full charge Approximately 10-12 hours continuous use (nominal) Battery Recharge Cycle -100% discharge 300 full charge/discharge cycles at room temperature and under normal discharge rates.  Wireless Pilot Probe Power Source Battery. Single use CR2, 3 V Lithium; capacity 750-850 mAh Wireless Pilot Probe Transmission Distance Up to 9 meters Industry Standard Wireless Operating Frequency 2.4 GHz. Fuse – Control Unit UL/CSA (198G) standards; 0.75 amp. Glass housing. 250 volt rating. 5x20m.  IEC 127 standards: Type 7. 0.63 amp,  250 volts. 5x20m T0.63AL250V. Sound Indicators Pitch variations - Frequency proportional to event rate. Upon completion of 10-second count, device emits double-beep sound.  Visual Indicators Control Unit: • Digital count – Vacuum fluorescent display • Single count – LED • Calibration-check - LED • 10-second count – LED • Battery energy level – LED • Range 1X/10X/100X – LED • Isotope – LED (four) Battery: • Battery state-of-charge – 4 LED’s Wireless Pilot Probe: • Probe connection – LED • Isotope Indicator – LED
Navigator 2.0 User Manual & Service Guide N2-5000-07-001 Rev 2  -38-  Revised 10/21/2015 Item Description Energy Range 0 - 650 keV Operating Conditions Operating Temperature Range: 15°C to 40°C (5°F to 104°F)  Storage  Temperature: -10°C to 85°C (15°F to 185°F) Humidity: 0%-80% relative humidity Atmospheric Pressure: 50 kPa to 106 kPa Maximum Count Rate 90,000/s Color of Housing Light gray and dark gray Control Unit Dimensions 20cm W x 24cm H x 12cm D  Control Unit Weight w/Battery 2.0kg Accuracy 95%-99% across the dynamic range of the instrument with probes  9B. System Accuracy The  Navigator  2.0  System  with  Probe  counts  gamma  photons  that  proceed  from  radioisotopes.  At  event rates around 20,000 counts per second,  the event rate shown in the display may be slightly less  than the event rate seen by the probe. This is due to the possible occurrence of a second gamma photon during the short time period (a few microseconds) it takes the system to count a detected gamma photon.  The Navigator 2.0 Device exhibits at least 95% accuracy across its dynamic range.
Navigator 2.0 User Manual & Service Guide N2-5000-07-001 Rev 2  -39-  Revised 10/21/2015 10. Support Items The Navigator 2.0 control unit is typically supplied with a complete system. Support items may be purchased from  the  local  Dilon  Technologies  Navigator  representative.  At  time  of  publication  of  this  manual,  the primary support items have the following part numbers. Feel free to contact your local representative  for additional information.   10A. Product Part Numbers Table 10A-1. Navigator 2.0 System Support Items with Part Numbers Item  Dilon Part Number Navigator 2.0 Battery N2-8500-00 2-Bay Battery Charger  N2-8000-02 Battery Charger Power Cord  SC-2000-00 Batteries for Wireless Pilot Probe (pack of 10)  WP-8500-01 Navigator 2.0 Stand with Pole Clamps  N2-8800-00 6mm Diameter Cable (for CdTe Probes)  GP-4001-00 3mm Diameter Cable (for 12mm Lymphatic Mapping Probe)  PM-4000-20 Optional Storm Case (for travel and storage)  N2-8000-07 Gain Module for 12mm Probe  PM-4000-40 Optional Top Gun Collimator  SP-1800-00 End Cap for Wireless Pilot Probe (pack of 10)  WP-2000-10 Battery Holder for Wireless Pilot Probe (pack of 5)  WP-9050-00 Optional Co-Pilot Devices  GP-6801-00  10B. Sterile Drape A  sterile  drape  is  an  additional  accessory,  but  it  is  not  sold  or  supported  by  Dilon  Technologies.  Typical characteristics of a suitable intra-operative probe drape are as follows:  • Universal gamma probe cover, 5 x 24  • Sized with tapered tip to fit both straight and flexible probes  • Low density, soft polyethylene  • Telescopically folded w/rubber bands and medical grade tape strips  • Drape features:  o 100% guaranteed latex-free - All components, including rubber bands o All available EtO Sterile  o Strong and durable Anti-Static material
Navigator 2.0 User Manual & Service Guide N2-5000-07-001 Rev 2  -40-  Revised 10/21/2015 11. Maintenance 11A. Overview While the Navigator 2.0 System is virtually maintenance-free, the user should follow a number of steps to ensure proper performance prior to each use.  1. Check each system component for any visible signs of abuse, neglect, or wear, before each use and storage. This includes checking the following components and these features: Table 11A-1. Component Check Component Check Feature Check Control Unit Overall check - Housing, integrity of switches and integrity of connections. Battery Charger  Overall check - Housing and integrity of connections. Probe (Wireless or cabled) Overall check. Also tip and connector.  Cable (if used) Each connector, the connector pins, and integrity of cable. Gain Module (if used) Dial, cable and connector.  • Should  abnormalities  be  discovered,  contact  your  sales  representative  or  Dilon  Technologies directly. • Do not use a damaged control unit, battery, battery charger, probe, cable, or gain module.  2. Check each battery for function and charge before use. Should abnormalities be discovered, contact your sales representative or customer support person.  3. To ensure proper functionality, follow each step as outlined in Section 4: “Control unit, Battery, and Co-Pilot,” and the section in the manual pertaining to the relevant probe.  4. In addition to the above, preventive maintenance suggests that every two years a new battery, fuse and cable (if used) might be considered.  5. User maintenance for the Wireless Pilot Probe is restricted to battery and battery cap replacement. There  are  no user  serviceable  components  or  items on  the  Pilot  Probe.  Do  not  attempt to  repair damaged battery contacts, or any other damage to the probe.  WARNING!  No modification of this equipment is allowed.  Any modification to this will void any remaining warranty, if attempted.  11B. Verification of Standard Gain (Calibration Quick Test)  The Navigator 2.0 system is designed to minimize periodic maintenance, such that would be performed by a clinical engineering department or the manufacturer. Depending on the probe used, one of two procedures can be performed by the user.  11B-1. Verification of Standard Gain (Calibration Quick Test) - Background For CABLED PROBES only. Applies to the Standard Lymphatic Mapping Probes (SP-2A14-67 & SP-2S14-67), Superficial  Head  &  Neck  Probe  (SP-2S11-53),  Laparoscopic  Probes  (SP-2S10-19  and  SP-2S10-31),  and  the Daniel™ Lung Probe (SP-2S10-31D).. Some institutions perform this Verification of Standard Gain every six months or every year.  The procedure does not calibrate the system; it simply  reveals whether or not the probe and control unit are set to a common gain standard (calibration). That common standard relates the
Navigator 2.0 User Manual & Service Guide N2-5000-07-001 Rev 2  -41-  Revised 10/21/2015 gamma photon energy detected by the probe to an energy window inside the control unit.  The Verification of  Standard  Gain  uses  122  keV  energy  photons  produced by  the Isotope  of Cobalt-57,  to create a  known  signal  in  the  probe.  The  control  unit  expects these detected  photons  to  be  in  an energy window corresponding to the CENTERED (>0<) position of the test. The control unit also has a test setting for an  energy  window  BELOW  (-)  the  expected  signal,  and  an  energy  window  for  a  signal  ABOVE  (+)  the expected  signal.  The  desired  outcome  of  the  test  is  that  the  signal  is  greatest  in  the  CENTERED  (>0<) position, as revealed by the highest count rate seen in the control unit’s display. The details of the test are given below.  11B-2. Verification of Standard Gain (Calibration Quick Test) – Procedure. For CABLED PROBES only. 1. Clean the PROBE and, if used, the CABLE.  2. Charge the BATTERY, and install it into the CONTROL UNIT.  3. Place the system controls as indicated in Table 11B-2, “System Configuration - Cobalt-57 Alignment”.  4. Align a 57 Cobalt source directly with the probe tip. Maintain this exact position between the source and the probe tip for the duration of the test. 5. Place the system controls as indicated in Table 11B-2 “System Configuration - Cobalt-57 Alignment.” 6. Place  the  SCAN/Calibrate  Control  in  the  CENTERED  position,  which  is  indicated  by  the  following symbol on the SCAN/Calibrate Control (>0<). Obtain a ten-second count. Record this total.  7. Place the SCAN/Calibrate Control in the BELOW position which is indicated by the following symbol on the SCAN/Calibrate Control ( - ). Press the COUNT control to obtain a ten-second count. Record this total.  8. Place the SCAN/Calibrate Control in the ABOVE position which is indicated by the following symbol on the SCAN/Calibrate Control ( + ). Obtain a ten-second count. Record this total.  9. The  highest count  should  be when the  SCAN/Calibrate  Control is in  the CENTERED (>0<)  position. The count in the ABOVE position ( + ) and the count in the BELOW position ( - ) should be less than the count in the CENTERED ( >0< ) position. The observance of these relationships verifies that the probe and control unit have the same standard gain.  10. Return the SCAN/Calibrate Control to the SCAN position.  11. Return the other system controls to the settings for normal use.  12. End of Test.   Table 11B-2. System Configuration – Cobalt-57 Alignment during Calibration Quick Test Component/Feature  Setting Cabled Probe Cable connected to probe input CALIBRATE control (rear panel) (>0<), ( - ), ( + ) ISOTOPE control (rear panel) Technetium-99m THRESHOLD control As desired (no effect) POWER switch ON RANGE control As desired VOLUME control As desired  NOTE:  Because  the  system  is  designed  to  detect  slight  changes  in  the  location  and  intensity  of radioisotopes, the test source must be maintained in the same direct alignment and distance from the probe tip throughout the three calibration tests.
Navigator 2.0 User Manual & Service Guide N2-5000-07-001 Rev 2  -42-  Revised 10/21/2015  NOTE:   The  front  panel  CALIBRATION  INDICATOR  blinks  when  the  SCAN/Calibrate  Control  is  in  either  the BELOW ( - ), CENTERED (>0<), or ABOVE ( + ) test position. The CALIBRATION INDICATOR is OFF when the CALIBRATION control is in the SCAN position.  NOTE:  All Dilon Technologies probes can be used with any Navigator 2.0 control unit. The 12mm Lymphatic Mapping Probe, used with a Gain Module, requires a different method of peak calibration assurance, detailed in the section 7A, entitled “Running a Peak Procedure".”  11C. Fuse Replacement Procedure The fuse is to be replaced when necessary by the user (when the fuse is "blown"). The Navigator 2.0 fuse is to be replaced as follows: 1. Push-in and twist the fuse holder cap counter-clockwise.  2. Remove the fuse from the fuse holder.  3. Insert a new fuse into the holder.
Navigator 2.0 User Manual & Service Guide N2-5000-07-001 Rev 2  -43-  Revised 10/21/2015 4. Press-in and twist the fuse holder cap clockwise to lock it in place
Navigator 2.0 User Manual & Service Guide N2-5000-07-001 Rev 2  -44-  Revised 10/21/2015 12. Repair Probes are sealed at the factory. No user serviceable parts are inside the probes. Damage to a probe may result if a probe is opened by the user and will void any remaining warranty, if attempted.  Serviceable parts on the Navigator 2.0 control unit include a fuse, which may be inspected and replaced by the user, and a replaceable battery. Beyond these two items, the control unit contains no user serviceable parts and should not be opened by the user.  Please  contact  Dilon  Technologies  for  additional  service.  An  RMA  number  is  required  upon  return  for service. If  the  device  cannot  be  repaired  and  or  it  is  determined  that  its  useful  life  is  at  an  end,  contact  Dilon Technologies for proper disposal of the unit.     12050 Jefferson Avenue Suite 340 Newport News, VA 23606  USA Phone: +1-844-DILONNAV www.Dilon.com    CAUTION:  Before  using  loose  packing  materials,  such  as  foam  pellets, shredded  paper,  or  excelsior,  be sure  to  wrap  the  component(s)  separately  in  protective  bags  or  other  protective  wrapping upon return for repair.   CAUTION:  If  a  system,  or  system  components,  are  to  be  shipped  from  your  institution  for  repair,  then please  clean  and  disinfect  the  components  as  described  in  this  manual  before  packing  for shipment.  Dilon  Technologies  require  that  the  Navigator  Service  Sheet  be  attached  to  the outside of the shipping box, certifying that the items have been cleaned and disinfected to manufacturer’s  specifications.  This  form  can  be  found  on  the  Dilon  Technologies  website (www.DilonProducts.com) or by contacting your distributor or Dilon Technologies directly.
Navigator 2.0 User Manual & Service Guide N2-5000-07-001 Rev 2  -45-  Revised 10/21/2015 13. Recycling At the end of the device life and/or accessories, please send the device and/or its accessories back to Dilon Technologies Authorize Representative in Europe.  Ensure the cleaning of the device and/or it accessories before shipment.  The disposables of the product are made out of plastic and cannot be reused and must be disposed as standard disposables.
Navigator 2.0 User Manual & Service Guide N2-5000-07-001 Rev 2  -46-  Revised 10/21/2015 14. Limited Warranty Dilon Technologies (Dilon), warrants to its customers that, subject to the below provisions, the Navigator 2.0 system  and  probes  will  be  free  from  defects  in  materials  and  workmanship  for  twelve  (12)  months, commencing upon the date of shipment from Dilon.  Replacement parts and products are warranted to be free from defects in material and workmanship for a period equal to the balance of the warranty period remaining on the original part or product.  Dilon will repair or replace, at its option and without charge, any of the above products which are returned to Dilon or its designated repair site, within the  applicable  warranty period, with prepayment of shipping costs, and which are determined by Dilon to be defective in materials or workmanship.  This Limited Warranty does not apply to any product or replacement part or replacement product which has been subjected to any damage as a result of an accident or abuse, or that has not been used and maintained in accordance with the information contained in the literature accompanying the product, or that has been modified, repaired or serviced by any person or company other than Dilon or its authorized representative.  Dilon’s sole liability for any defective product shall be repaired or replaced as set forth above. Dilon shall not be liable to anyone, under any circumstances, for any special, punitive, incidental or consequential damages whatsoever,  including  without  limitation  any  costs,  expenses,  lost  profits  or  other  losses  however designated.  EXCEPT  AS  STATED  ABOVE,  NO  WARRANTIES  ARE  EXPRESSED  OR  IMPLIED,  INCLUDING, WITHOUT LIMITATION, ANY WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, AND, EXCEPT AS STATED ABOVE, DILON EXPRESSLY DISCLAIMS ALL WARRANTIES.     Manufactured by: Authorized European Representative: Dilon Technologies 12050 Jefferson Avenue Suite 340 Newport News, VA 23606  USA Phone: +1-844-DILONNAV www.Dilon.com   AG Medical  Route de l'Orme, Parc des Algorithmes  -  Imm. "Homère" 91190 Saint-Aubin , France http://ag-medical.com/   2014 Dilon All Rights Reserved. May 2014 Made in USA