Dimplex North America 00005 Hub Transceiver for Heating Control User Manual statements

Dimplex North America Limited Hub Transceiver for Heating Control statements

User Manual statements

Download: Dimplex North America 00005 Hub Transceiver for Heating Control User Manual statements
Mirror Download [FCC.gov]Dimplex North America 00005 Hub Transceiver for Heating Control User Manual statements
Document ID2042216
Application IDcifv4t51hTy5C+4KdQYQJw==
Document DescriptionUser Manual statements
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize43.45kB (543177 bits)
Date Submitted2013-08-14 00:00:00
Date Available2013-08-15 00:00:00
Creation Date2013-06-21 12:15:08
Producing SoftwareGPL Ghostscript 8.15
Document Lastmod2013-06-21 12:15:08
Document TitleMicrosoft Word - Quantum rf System Installation.docx
Document CreatorPScript5.dll Version 5.2.2
Document Author: patrick.johnson

Quantum rf System Installation
rf System Required Components:
1.
2.
3.
4.
5.
6.
915MHz Hub.
+5V to +12V DC Power Supply.
Ethernet Cable.
USB to microB Cable (not supplied).
Lap Top PC with Quantum LAN Tool installed.
Installation/Operation of LAN Tool for QuantumTM Hub (three page document).
Rf System Installation:
1.
2.
3.
4.
Mount the Hub on a wall near a power outlet, as high as possible.
Plug in the power supply and turn on power.
Connect to the PC via the USB cable.
Start the Quantum LAN Tool.
Refer to the Installation/Operation of LAN Tool for QuantumTM Hub document.
5. Power cycle the HUB when the LAN tool prompts you.
The LAN Tool display should now look like this:
6. You are now ready to establish communication to Quantum Storage Heaters with rf
capability. Follow the steps in the Example below.
Quantum rf System Installation
Example of System setup:
This example will guide you through a typical setup.
For this example we will assume there are 4 Quantum storage heaters installed in a home or office
and all 4 storage heaters have 915MHz transceivers installed and rf comms enabled. We will also
assume that the 4 storage heaters are powered on and the above rf system installation has been
completed.
1. Left click the “List Config” button in the top left hand corner of the LAN Tool window.
The Hub should report “Currently no paired Nodes. Paired: 0” as in the screen shot below.
If the Hub reports any paired nodes, delete them as described in the “Deleting Paired
Nodes/Appliances” section below.
2. Left click the “Scan/Pair apps” button in the top left hand corner of the LAN Tool window.
This process may take up to 45 seconds to complete.
When this process completes, left click the “List Config” button as in step 1.
The Hub should now report “Paired: 4” (for this example).
Deleting Paired Nodes/Appliances:
1. Left click the “Delete paired apps” button. When prompted, click Yes, or No to selectively
delete each individual appliance from the paired list.
Quantum rf System Installation
Reading Paired Appliances:
1. You can read data from a paired appliance by left clicking the “Read paired apps” button and
selecting Yes or No for a particular appliance, when prompted. Below is an example of the
data returned after a read.
FCC ID:Z4900005
IC: 6592A-0005
This device complies with Part 15 of the FCC Rules and with Licence exempt RSS standards of Industry
Canada.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause
undesired operation.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio
exempts de licence. L'exploitation est autorisée aux deux conditions suivantes:
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le
brouillage est susceptible d'en compromettre le fonctionnement.
WARNING: Changes or modifications not expressively approved by the party responsible for
compliance could void the user's authority to operate the equipment. The term “IC:” before the
radio certification number only signifies that Industry Canada technical specifications were met.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Count                      : 3
Producer                        : GPL Ghostscript 8.15
Create Date                     : 2013:06:21 12:15:08
Modify Date                     : 2013:06:21 12:15:08
Title                           : Microsoft Word - Quantum rf System Installation.docx
Creator                         : PScript5.dll Version 5.2.2
Author                          : patrick.johnson
EXIF Metadata provided by EXIF.tools
FCC ID Filing: Z4900005

Navigation menu