01 51128C DC2000 0151128
User Manual: DC2000
Open the PDF directly: View PDF .
Page Count: 2
Download | |
Open PDF In Browser | View PDF |
DC2000 Back-Up Wiring for the OmniControl™ Board with Optional Equipment SAFETY OPTIONS System Setup “Manual” setting: The DC2000 will respond to the input devices wired to the J 20 socket. “Optional Edge Sensor” This mode can also be used as an emergency override. If 115 Vac power is on, but the system has an electronic malfunction, the gate can be operated using the DC2000 system with input devices wired to J 20 socket. EMERGENCY OVERRIDE “Auto” setting: The DC2000 opens the gate automatically upon 115 Vac power failure and stays open. When 115 Vac power is restored, the gate operator will return to normal operation. (The gate can be closed by manual command) 115 Vac Power On, OmniControl Board™ Malfunction 115 Vac Power On, Emergency Override Push and Hold to operate gate Turn the 115 Vac power off then push and Hold to operate gate Push and Hold to override the OmniControl™ Board Gate automatically opens Turn the 115 Vac power off then gate opens automatically Push and Hold to override the OmniControl™ Board If 115 Vac power is on, but the system has an electronic malfunction, the gate can be operated using the DC2000 system with ANY of these devices shown. “Optional Manual One-Button” SENSOR ALARM Manual Mode Auto Mode 115 Vac Power Failure DC-BACKUP Push and “Hold” to Open Push again and “Hold” to Close “Optional Photocell Sensor” 12 VDC POWER OVERLOAD Part # AOMRON12V OmniControl™ Board Sensor Connection Part # AEXITP Power Ground 4 5 Power +12 VDC 4 USE ONLY 12 VDC FAILSAFE PHOTOCELL SENSORS FOR THIS SAFETY OPTION Failsafe Photocell: If a photocell is not working or loses power or photo beam is blocked, then the photocell will stop all gate operation. 6 “Optional Key Switch” r 00 Ha DC20 ness If the DC2000 is automatically opening the gate due to a power failure, any manual command such as “Manual One-Button”, “Three Push Button”, “Key Switch”, “Photocell” or “Edge Sensor” will cancel the automatic mode of the DC2000. After such cancellation, the DC2000 will continue to operate in manual mode until 115 Vac power is restored. DO NOT wire 115 Vac power to the DC2000 1 56 4 3 2 4 7 5 E OPEN J 20 Socket 3 CLOS 4 Part # A1KX Inte rlo ck As Turn and “Hold” to Open sem bly Wir e Turn again and “Hold” to Close To Limit Switches Interlock Assembly ON OFF “Optional Three-Button” N.O. 4 2 4 1 4 Com EXIT SAFETY CENTER 3 N.O. N.O. Com “Optional Radio Receivers” SENSOR ALARM DC-BACKUP Com Push and “Hold” a Button to operate W4 SYSTEM ON TIMER 3 1 3 REVERSE SENSOR 1 60 1 OFF OPEN RIGHT STRIKE OPEN RADIO RECEIVER GATE LOCKED EXIT LOOP SAFETY LOOP CENTER LOOP RESET MOTOR DO NOT remove existing wires from the audio alarm or secondary protection sensor. LOSE CLOSE CLO COMMAND PROCESSED CENTER SAFETY FIRE DEPT. MADE IN CHINA A 5 6 4 4 P/N Q410 + B A Center Loop M/S Link Exit Loop Fire Dept Key Switch Strike Open Push Button Radio Receiver J5 Class 2 Supply 24 Volts DC CK BACK -B J5 DC-BACKUP Black 120 White Neutral Green Ground CAUTION Vac CHASSIS GROUND Safety Loop SENSOR ALARM OmniControl Surge SuppressorPatent Pending 11 12 13 G 4 3 Factory installed Interlock Assembly Wires to J20 Socket DC2000 Harness For Technical Support and Ordering Parts: 1-800-528-2806 13 12 11 11 Radio Receiver + Radio Receiver - 4 Part # 312HM Jumper P2: to Constant (C) Jumper P3: to 12 Volt Button Three: Optional Accessories White Wire Audio Alarm Wires POWER OVERLOAD 1 2 3 Red Wire 11 13 11 12 Cut and Discard Plug DC er V 2 te 1 Receiv a r a Sep Radio 00 0 2 DC 3 ON OPEN LEFT Refer to Receiver Manual for Further Details about settings. POWER OVERLOAD 3 EXIT ALARM SENSOR SENSORS OPEN MS LINK STOP G B A 1 2 3 4 DC 24 V nstalled ry I r o t c eive Fa c e io R Rad Button Two: Back-Up Operation (DC2000) Button One: Normal Gate Operation (OmniControl™ Board) Part # 373LM Green and Purple wires wrap behind board to the limit switches Button One: Normal Gate Operation Only (OmniControl™ Board) Push and “Hold” DC2000 Remote Button to Open Push again and “Hold” DC2000 Remote Button to Close DC2000 Back-Up Installation for SL3000UL™ models SL3000UL™ & SL3000ULDM™ Step-by-Step DC2000 Installation STEP 1 STEP 2 A B C Bolt the DC2000 plate and guard to the operator chassis. Do not tighten the bolts. Adjustment is required in Step 3. STEP 3 A B Bolt the DC2000 control unit to the plate. Bolt the DC motor to the plate. Connect the DC motor wires to the DC2000 control unit wires. Red to Red and Black to Black. STEP 4 A B C D Replace the existing belt with the new belt provided. Make sure that the pulleys are aligned. Pull down the DC2000 Plate to tighten the belt tension. Tighten the plate bolts to secure the plate. Remove the OmniControl™ board from the electrical box. Plug in the DC2000 harness into the DC2000 control unit. Feed the DC2000 harness through the bottom of the electrical box. Feed the green and purple wires to the limit box. OFF Existing Belt ON D A A A DC2000 Control Unit C Plate DC Motor Bolts W4 B Plate STEP 5 STEP 6 A B C D A B A Do not over tighten belt B SL3000UL™ SL3000ULDM™ Use 4L 370 Belt Use 4L 400 Belt STEP 7 Connect the purple and green wires to the limit switches. Make sure brown wire is in the “Common” connector on the limit switch. A Set switch for the gate direction. (Open left or Open right) B Select your mode of operation for the DC2000 unit. (Automatic open or Manual open) C Permanently wire optional controls according to label on control unit. (See back page) D Adjust the sensitivity for the reverse sensor. Top View of Limit Switch Box ON Reinstall the OmniControl™ board and make sure that the green and purple wires do not get pinched by the board. Plug in the DC2000 harness in the DC-BackUp J5 slot on the OmniControl™ board. Connect the red wire from the DC2000 harness into the top slot of the audio alarm plug. (DO NOT remove audio alarm wires) Connect the white wire from the DC2000 harness into the bottom slot of the sensor plug. OFF B B Guard C 2 NC NC NO 3 COM NO 2 1 B 3 COM B Yellow Orange Purple CK BACK -B DC-BACKUP 1 Brown Red Green J5 SENSOR ALARM B W4 D A C A D A POWER OVERLOAD C SL3000UL™ & SL3000ULDM™ with Interlock Assembly Step-by-Step DC2000 Installation Bolt the DC2000 plate and guard to the operator chassis. Do not tighten the bolts. Adjustment is required in Step 3. A B C STEP 4 STEP 3 Bolt the DC2000 control unit to the plate. Bolt the DC motor to the plate. Connect the DC motor wires to the DC2000 control unit wires. Red to Red and Black to Black. A B C A STEP 5 Unplug interlock wire from OmniControl board, cut the plug off and strip wires. Insert Red wire in J-20 socket 3 and Black wire into socket 4 of the DC2000. Remove interlock assembly from motor with 3 screws. Replace the existing belt with the new belt provided. Make sure that the pulleys are aligned. Pull down the DC2000 Plate to tighten the belt tension. Tighten the plate bolts to secure the plate. Reattach interlock assembly. A B C D Remove the OmniControl™ board from the electrical box. Plug in the DC2000 harness into the DC2000 control unit. Feed the DC2000 harness through the bottom of the electrical box. Feed the green and purple wires to the limit box. D OFF Existing Belt A Interlock Assembly B B DC2000 Control Unit A A C Plate DC Motor C Bolts ON STEP 2 STEP 1 W4 C Plate A C STEP 6 B SL3000UL™ SL3000ULDM™ Use 4L 370 Belt Use 4L 400 Belt Socket 3 & 4 A B STEP 8 Connect the purple and green wires to the limit switches. Make sure brown wire is in the “Common” connector on the limit switch. A Set switch for the gate direction. (Open left or Open right) B Select your mode of operation for the DC2000 unit. (Automatic open or Manual open) C Permanently wire optional controls according to label on control unit. (See back page) D Adjust the sensitivity for the reverse sensor. Top View of Limit Switch Box ON Reinstall the OmniControl™ board and make sure that the green and purple wires do not get pinched by the board. Plug in the DC2000 harness in the DC-BackUp J5 slot on the OmniControl™ board. Connect the red wire from the DC2000 harness into the top slot of the audio alarm plug. (DO NOT remove audio alarm wires) Connect the white wire from the DC2000 harness into the bottom slot of the sensor plug. 7 Do not over tighten belt STEP 7 OFF A B C D 1 B Guard 56 234 2 NC NC NO 3 COM 2 NO 3 COM B Yellow Orange Purple CK BACK -B DC-BACKUP 1 Brown Red Green B SENSOR ALARM J5 D A C W4 1 B A D POWER OVERLOAD A C For Technical Support and Ordering Parts: 1-800-528-2806 01-51128C © 2013 The Chamberlain Group, Inc. All Rights Reserved 845 Larch Avenue Elmhurst, Illinois 60126 www.liftmaster.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Encryption : Standard V2.3 (128-bit) User Access : Print, Extract, Print high-res XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Create Date : 2013:02:06 14:51:53-07:00 Modify Date : 2013:06:10 15:12:31-07:00 Creator Tool : Adobe InDesign CS6 (Macintosh) Metadata Date : 2013:06:10 15:12:31-07:00 Producer : Acrobat Distiller 10.1.1 (Macintosh) Format : application/pdf Creator : The Chamberlain Group, Inc. Title : 01-51128C.indd Document ID : uuid:31271999-b06f-d04d-84b5-932a73e8f25c Instance ID : uuid:af2547cc-7289-e24c-b04d-64f3b74bf079 Schemas Namespace URI : http://ns.adobe.com/pdf/1.3/ Schemas Prefix : pdf Schemas Schema : Adobe PDF Schema Schemas Property Category : internal Schemas Property Description : A name object indicating whether the document has been modified to include trapping information Schemas Property Name : Trapped Schemas Property Value Type : Text Page Layout : SinglePage Page Mode : UseOutlines Page Count : 2 Author : The Chamberlain Group, Inc.EXIF Metadata provided by EXIF.tools