MIniCatalog'17 A60C 09minicatalog

User Manual: A60C

Open the PDF directly: View PDF PDF.
Page Count: 8

IRROMETER Model “LT”
(Low Tension)
is designed
for situations where tensions above 30 cb (kPa) are rarely expected. Ideal
for very coarse soils and non-soil container-media or where rapidly
changing soil water status needs to be observed. Incorporates a replaceable
“Quick-Flo” Tip (blue color), and low tension vacuum gauge. *
Includes reservoir, air free gauge chamber and hermetically sealed
IRROMETER Vacuum Gauge with 0 to 40 scale of centibars or
kilopascals (0 -40 cb [kPa] range).
Model “LT” (Low Tension)
IRROMETER Model “R”
our standard model, for general use with row,
tree, and field crops.
*
Includes reservoir, air free gauge chamber and hermetically sealed
IRROMETER Vacuum Gauge with 0 to 100 scale of centibars or kilopascals
(0 -100 cb [kPa] range).
*IMPORTANT NOTICE — Service Unit should be purchased with initial
*order (see page 2). Only one Service Unit is necessary to service all
*of your IRROMETERS.
Please order by Catalog Number. — Options and Accessories on Page 2 —
Soil Moisture Indicators
CATALOG
EFFECTIVE JANUARY 1, 2017 All Products Made in U.S.A., except where indicated.
Supersedes all previous price lists. All product labeling and instructions printed in English except where indicated.
IRROMETER Model “SR”
has threaded replaceable tip,
for general use with row, tree and field crops.
*
Includes reservoir, air free gauge chamber and hermetically
sealed IRROMETER Vacuum Gauge with 0 to 100 scale of
centibars or kilopascals (0 -100 cb [kPa] range).
CAT. NO. LENGTH
206 ............................. 6''.
complete
(15 cm)
212 ........................... 12''.
complete
(30 cm)
218 ........................... 18''.
complete
(45 cm)
224 ........................... 24''.
complete
(60 cm)
236 ........................... 36''.
complete
(90 cm)
248 ......................... 48''.
complete
(120 cm)
(Longer lengths available)
SRT .............................Replacement Tips
CAT. NO. LENGTH
312 ......................................... 12'' (30 cm)
318 ......................................... 18'' (45 cm)
312-LT .................................... 12'' (30 cm)
318-LT .................................... 18'' (45 cm)
Model “R” (Agriculture)
IRROMETER Model “MLT”
(Miniature Low Tension)
designed for applications similar to the Model “LT” above. Ideal for
use with very coarse soils and non-soil container-media. Its compact
size and replaceable “Quick-FloTip make it the best choice for small
container applications.
*
Model “MLT” (Miniature Low Tension)
Model “TG” (Turf)
IRROMETER Model “TG”
f
or shallow rooted applications or
where installation requires horizontal placement of the sensing tip.
Also available in Low Tension.
*
Model “SR” (Replaceable Tip)
951/682-9505 www.IRROMETER.com
Save
Water!
IRROMETER Model “S”
has a threaded
connection at the top of the tube. Designed for research work
where change in instrument length is required for different
experiments
, and for general use with row, tree, and field
crops.
When ordering, select Extension Tip(s) in combination
with the Reservoir Section.
*
Includes reservoir, air free gauge chamber and hermetically
sealed IRROMETER Vacuum Gauge with 0 to 100 scale of
centibars or kilopascals (0 -100 cb [kPa] range).
Model “S” (Research)
Model “S”
Model “SR”
Model “R”
Model “LT”
Model “MLT”
Model “TG”
Bronze Member
CAT. NO. LENGTH
106 ........................................... 6'' (15 cm)
112 ......................................... 12'' (30 cm)
118 ......................................... 18'' (45 cm)
124 ......................................... 24'' (60 cm)
136 ......................................... 36'' (90 cm)
148 ....................................... 48'' (120 cm)
(Longer lengths available)
CAT. NO. LENGTH
200 ..........................
Reservoir Section only
EXTENSION TIPS:
E6 ........................................... 6'' (15 cm)
E12 ........................................ 12'' (30 cm)
E18 ........................................ 18'' (45 cm)
E24 ........................................ 24''.(60 cm)
E36 ........................................ 36'' (90 cm)
E48 ....................................... 48''(120 cm)
CAT. NO. LENGTH
506 .......................................... 6'' (15 cm)
512 ......................................... 12'' (30 cm)
518 ......................................... 18'' (45 cm)
524 ......................................... 24'' (60 cm)
536 ......................................... 36'' (90 cm)
(Longer lengths available)
QFSRT ........................ Replacement Tips
CAT. NO. LENGTH
MLT ......................................... 6'' (15 cm)
1007 ............................... MLT Service Unit
MLT-TIP ....................... Replacement Tips
IRROMETER
®
Includes hermetically sealed IRROMETER
Vacuum Gauge with 0 to 100 scale of centibars
or kilopascals (0 -100 cb [kPa] range).
Includes hermetically sealed IRROMETER Vacuum Gauge with 0 to 40 scale of centibars or kilopascals (0 -40 cb [kPa] range).
Option “RSU-C” and
“RSU-V” – Remote
Sensing Units
are
designed to show
soil moisture levels
by converting the
reading to either
a 4-20 mA loop
current signal or
a .5 - 4.5 voltage
signal. In both
options, the built-in pressure transducer is temperature compensated to improve
accuracy and is liquid compatible. All electronics are sealed in a potted, waterproof
housing with external vent. The signal can be read by a data-logging device or an
A/D card designed to read voltage. (Current output option requires 12-24 VDC
excitation current and Voltage output option requires 5 VDC excitation current.)
Service Units
Standard Service Unit
CAT. NO. 1001
Includes:
01 Hand Vacuum Pump
01 Bottle IRROMETER Fluid
25 Monthly Chart Forms
01 Reference Book
(Available in Spanish, specify #1001-SP)
Test Pump Service Unit
CAT. NO. 1002
Includes:
Same items as #1001,
except Hand Vacuum Pump
is equipped with test gauge.
Automation and Output Options
CAT. NO.
1003
Test Pump Adapter
1004 IRROMETER Fluid (1 oz. concentrate)
1004-L
IRROMETER Fluid (6 oz. concentrate)
1005
Chart Forms
(MONTHLY)
P-2001
Model “P” Portable
IRROMETER
12" with handle for easy removal
(other lengths available)
IRROMETER Vacuum Gauges
1008 Replacement Gauge
(0-100 cb[kPa])
1008-A
* *
Automatic Gauge
(0-100 cb[kPa])
with switching capabilities (specify as listed above)
1008-
LT
Replacement Gauge
(0-40 cb[kPa])
for Model LT
1008
-
LT-A
* *
Automatic Gauge
(0-40 cb[kPa])
for Model LT with switching capabilities
(specify as listed above)
CAT. NO.
1008-
MLT
Replacement Gauge
(0-40 cb[kPa])
for Model MLT
1009
-
Replacement Solid State Switch only
for Automatic Gauges (Afor AC or Dfor DC)
1010-
S
Replacement Auto Gauge
Standard action without switch
1010-
R
Replacement Auto Gauge
Reverse action without switch
RSURemote Sensing Units
(C & V))
RSU-C-34-1/8
0-34 cb (kPa)
for use with Model MLT (1/8 NPT)
RSU-C-34-1/4
0-34 cb (kPa)
0
for use with Model LT (1/4 NPT)
RSU-C-93-1/4
0-93 cb (kPa)
for use with Model R, S, SR, TG (1/4 NPT)
CAT. NO.
RSU-V-1/8
Voltage Option for MLT
RSU-V-1/4
Voltage Option for R, S, SR, TG, LT
Replacement Tips & Other Items
SRT
“SR” Replacement Tip (threaded bushing)
RTWOT
Replacement Tip (without threads)
QFSRT
“LT” Replacement Tip
MLT-TIP
“MLT” Replacement Tip
CAP IRROMETER
Cap and Stopper Assembly
STOP
Stoppers
SR-O
O-Ring (Model SR/LT)
Option A” – Automatic Gauge –
provides
direct switching capabilities in addition to
indicating available soil moisture. Soil
water tension readings above the moisture
setting can activate an irrigation valve
solenoid, time clock or warning device. A
switch mechanism (AC or DC) is mounted
on the gauge and rotated to desired
setting. The gauge reads in centibars (cb)
and kilopascals (kPa) of soil water tension.
-
RSU-C
Remote Sensing Unit
- Current
SUFFIX FOR MODELSN
RSU-C-93
(0-93 kPa) ..................................
R, S, SR, TG
RSU-C-34
(0-34 kPa) ................................................ LT
RSU-C-34
(0-34 kPa) ............................................. MLT
-
RSU-V
Remote Sensing Unit
- Voltage
SUFFIX FOR MODELS
RSU-V
.............................................................
R, S, SR, TG
RSU-V
.......................................................................... LT
RSU-V
....................................................................... MLT
951/682-9505 www.IRROMETER.com
Save
$$$!
2
Cat. No. 1001
SERVICE UNIT
Cat. No. 1002
TEST PUMP SERVICE UNIT
These options provide automation for irrigation valves and electronic output for
use with automatic data collection systems. They can be added at the factory when
purchased (as shown here) or added to your existing instruments in the field (as
accessory items, see below).
Accessory Items
*
Refer to Automation and Output Options (above) for
appropriate suffix.
Note: Contact factory for switch calibration information.
MLT Service Unit –
CAT. NO. 1007 —
Includes:
Same items as #1001, except Vacuum Pump is syringe style.
The Standard Service Unit is used during initial
installation and then periodically for removal of air
from instrument to ensure maximum sensitivity and
accuracy. The Test Pump Service Unit serves the
dual purpose of removing air and testing the gauge in
one operation.
IRROMETER
A Service Unit is necessary for proper
operation of the IRROMETER instrument and
should be included on initial orders. One
unit will service all of your IRROMETERS.
-A Automatic Gauge
For Models
R, S, SR, TG, LT
SUFFIX
-
AAS
w/AC switch closed past setting
-
AAR
w/AC switch open past setting 5
-
ADS
w/DC switch closed past setting
-
ADR
w/DC switch open past setting
-
A
__
for Model MLT
This suffix must be added to the catalog number and price must
be added to your choice of IRROMETER when ordering to
receive a complete instrument.
This suffix must be added to the catalog number and price must
be added to your choice of IRROMETER when ordering to
receive a complete instrument.
RSU-C RSU-V
Gauge part numbering
nomenclature for ordering:
7 or 7LF Series Gauge
Pressure Range:
OPTIONS
(choose one –
used with 7 Series only
)
Snubber
w/Snubber =
S(for 7 Series only)
For example a 100 psi automatic gauge
with a Snubber is 7-100-ADS-S.
Model SSAT (Complete)
For easy extraction of soil
solution samples when testing salinity levels or plant nutrients in
soil water, now with two models to choose from.
Series A
has vinyl
suction line with rubber stopper seal and pinch clamp closure.
Series B
has polyethylene/neoprene suction line with threaded
compression seal and ball valve closure. Both series A and B
require vacuum source. (see options below)
CAT. NO. – Series A
SLA
Suction Line Assembly (to 24")
(
Longer lengths available)
SLT-A
Bulk Vinyl Suction Line Tubing
FC
Finger Clamp
SGL-STOP
Single Hole Stopper
DBL-STOP
Double Hole Stopper
CAT. NO. – Series B
SLT-B
Bulk Polyethylene Suction Line Tubing
DLT-B
Bulk Neoprene Discharge Line Tubing
BV
Ball Valve
CS
Compression Seal
Model SSAT (Complete)
CAT. NO. LENGTH
A6C ................................. 6''.(15 cm)
A12C ............................. 12''.(30 cm)
A18C ............................. 18''.(45 cm)
A24C ............................. 24''.(60 cm)
A36C ............................. 36''.(90 cm)
A48C ........................... 48''.(120 cm)
A60C ........................... 60''.(150 cm)
A72C .............. .............72''.(180 cm)
Model SSAT (Complete)
CAT. NO. LENGTH
B6C ................................. 6''.(15 cm)
B12C ............................. 12''.(30 cm)
B18C ............................. 18''.(45 cm)
B24C ............................. 24''.(60 cm)
B36C ............................. 36''.(90 cm)
B48C ........................... 48''.(120 cm)
B60C ........................... 60''.(150 cm)
B72C ........................... 72''.(180 cm)
Soil Solution Access Tube
Pressure Gauges
951/682-9505 www.IRROMETER.com
Save
Time!
3
2
15
psi – 100 kPa
(available in 7 Series only)
2
30
psi – 200 kPa
(available in 7 Series only)
2
60
psi – 400 kPa
100
psi – 700 kPa
200
psi – 1400 kPa
400
psi – 2800 kPa
w/AC switch closed past setting = AAS
w/AC switch open past setting = AAR
w/DC switch closed past setting = ADS
w/DC switch open past setting = ADR
7 -100 -ADS -S
(7 Series only)
Hermetically Sealed – (7 Series)
Hermetically sealed pressure gauges are water tight,
dust proof, shock resistant, have a 2 in. (51 mm)
shatterproof face, and are bottom connected with 1/4
in. brass standard pipe thread stem (NPT). Dual scale
of P.S.I. and kPa.
OUTPUT OPTIONS:
Switching Gauge
– is a pressure gauge with direct
switching capabilities. Adjustable pressure selector
may be set to any desired pressure. The switch will be
closed past the setting to actuate connected device.
Switch available for AC or DC power and also in
reverse switch action (open past the setting).
Switching position selected should fall in the center 1/3
of the gauge range.
Liquid Filled – (7LF Series)
Glycerin filled
pressure gauges
, for severe service
conditions with pulsation and vibration, feature stainless
steel case with a durable polycarbonate 2-1/2 in. (63
mm) face, and are bottom connected with 1/4 in. brass
standard pipe thread stem (NPT). Dual scale of P.S.I.
and kPa. 7LF Series gauges now have integral
Snubbers.
Snubber
Factory installed Snubber improves gauge life by
absorbing surges. Snubber is threaded for removal and
cleaning if gauge becomes plugged with debris.
The DS-50CC Extraction Syringe is used primarily to extract
soil solution from SSAT Tube and can also be used to create a partial vacuum
on shorter tubes [12 in. (30 cm) or less]. For SSAT
Tubes longer than 12 in. (30 cm), the SSAT Vacuum
Pump (CAT. NO. 1002-SSAT) is required to create a
sufficient vacuum. Spanish instructions available
specify 1002-SSAT-SP.
1002-SSAT
............................. SSAT Vacuum Pump
DS-50CC
..................................... Extraction Syringe
Analysis kits and meters are available from Spectrum
Technologies, Plainfield, IL 800-248-8873 / 815-436-4440 or Hach
Company, Loveland, CO 800-227-4224, Int’l: 970-669-3050.
DS-50CC
1002-SSAT
SSATGAUGES
Accessories for Model
SSAT
Series A
OPTIONS
SUFFIX
-
LT
“Quick-Flo” Tips
-
DBL
Double Suction Line for long tubes
Tube only
Drop “C” from part number
Series B
OPTIONS
SUFFIX
-
LT
“Quick-Flo” Tips
For lengths longer than 72" (180 cm) – contact factory
(Series A Only)
New
Lower
Price
Data Shuttle
is used to collect data from the 900M
Monitor. Stores data on a multi media
card which is then transferred to the
user’s computer using the included
card reader. Includes Data Shuttle
with battery, cable, storage pouch, instructions, multi
media card, card reader and software.
CAT. NO. LENGTH
200SS-5 .......................................................... 5' (1.5 m)
200SS-15 ...................................................... 15' (4.5 m)
200SS-X ........................................................ 6" (15 cm)
(Longer lengths available)
–S Pipe spigot end added to WATERMARK
to make your own multiple depth profile probes.
PKG
Retail Packaging 5' (1.5 m)
200SS-VA-
Voltage Adapter
200SS-V-6
6 Channel Galvanic Isolator
Standard WATERMARK Soil Moisture
Sensor*. For use with all crops. To be
used with WATERMARK Meter, Monitor,
Voltage Adapter or a compatible device.
Reads electrical resistance in 0-200 centibar
(cb) and kilopascal (kPa) range. Comes standard
with half inch stripped and tinned ends.
Available with ring terminals as a special order.
*
Shipped in bulk unless specified to be in retail
packaging, 5' (1.5 m) only – (add PKG
)
Galvanic isolation may be required for some
reading devices. See 200SS-V-6.
CAT. NO.
30-KTCD-NL
WATERMARK Meter
30-KTCD-NL-SP
WATERMARK Meter
with Spanish label and instructions
30-KTCD-Cable
Replacement Cable
Soil Moisture Sensor
Meter
951/682-9505 www.IRROMETER.com
Less
Runoff!
4
WATERMARK
Solid state, digital hand-held, alternating
current resistance bridge meter for reading
standard WATERMARK Sensors. Adjustable
for soil temperature variations. Touch pad
operating panel with LCD display. Includes
durable case, 9 volt battery and field
replaceable cable assembly.
(Only one meter is
necessary to read multiple
WATERMARK Sensors)
Monitor
WaterGraph software for downloading data and graphic functions is available
free from our website with any monitor purchase.
“RSU” Wiring Adapter (not shown)
for reading IRROMETER Option “RSU” transducers.
One adapter required per four “RSUs” to convert the
sensor wiring. (includes batteries).
POPULAR MONITOR PACKAGES:
CAT. NO.
900M — WATERMARK Monitor
*
with seven WATERMARK Sensors and one Temperature
Sensor, each with 15' (4.5 m) wire leads.
900M-8 — WATERMARK Monitor
*
with eight WATERMARK Sensors, each with 15' (4.5 m) wire leads.
900M-1-6-PSI 60 — WATERMARK Monitor
*
with six WATERMARK Sensors, one Temperature Sensor, each
with 15' (4.5 m) wire leads and one 60 psi switching pressure
gauge (for recording irrigation events).
*No cable or CD included with these packages.
Battery operated data-logger that automatically reads
up to eight sensors. User can view readings on the
screen, download data to a computer, or use our Data
Shuttle to transport the information to a computer.
When combined with the Cellular Gateway option data
can be viewed on the Web from a remote location.
Monitor accepts WATERMARK Soil Moisture, soil
temperature, air temperature and switch closure
sensors, Rain Gauge, Voltage Transducer and
IRROMETER RSU. See Monitor Packages for sensor
combination options.
Data Access Option for the 900 Monitor improves
productivity by bringing important soil moisture
information to you. Remote areas and multiple crop
locations can be monitored from a central location.
Accessory hardware can be combined to suit your
application. A Cellular Gateway with battery pack
provides world-wide coverage via the Internet.
ACCESSORIES:
200SS-15 WATERMARK Sensor
with 15' (4.5 m) wire lead
200TS Temperature Sensor
with 15' (4.5 m) wire lead
900M-CG-BP
Cellular Gateway & 5WBattery Pack
(includes solar panel)
900AC AC Transformer
900DS
Shuttle, cable, multimedia card
900RG Rain Gauge
900M-RSU-C
“RSU” Current Wiring Board
(One board per four “RSUs”)
900M-RSU-V
“RSU” Voltage Wiring Board
(One board per eight “RSUs”)
Rain Gauge
includes bird spikes
and integral mounting
base.
Cellular Data Service (CDS-GPRS only)
provides automatic collection and
viewing of data from one Model 900 Monitor via IRROMETER supplied cellular Internet
connection. Works well in applications that have a good network of cellular radio towers.
(WEB BASED SERVICES ARE BILLED ANNUALLY.)
Telemetry Services
Let collect the data for you!!
CAT. NO.
CDS-2 Cellular Data Service
(2 mb per mo.)
.
________________________________________________________________
CDS-2
-INTL
Cellular Data Service
(2 mb per mo.)
*
Contact IRROMETER for specific country coverage and availability.
USA
& EU
*
INT’L
*
NEW
COMPONENTS:
900M-O Monitor Only
(without sensors)
NEW
-S
IRROmesh is a Wireless Sensor Network whose data can be directed to the web for the Internet
of Things environment. It provides real time data for Precision Agriculture applications. This
solar powered wireless data-logging system automatically reads up to 20 sensing locations with
no batteries required. Radio line of sight maximum 1000’ (305m) between nodes. Nodes
automatically establish a mesh network that is self-initializing, self-routing, and self-healing.
Data from each node relays along multiple paths to the base.
Data transmits to your computer or the WEB. A complete stand-alone system includes a Base, a Data
Collection Device, the desired number of Nodes and their Sensors. For real-time WEB access use the Cellular
Gateway with Battery Pack or PC Link.
951/682-9505 www.IRROMETER.com
Installs
Easily!
5
IRROmesh System
WATERMARK
**Nodes can be ordered from the factory with Bird Deterrent Covers or retro-fit with an in-field install cap.
975 Components
CAT. NO.
975B
Base
Standard Mesh System Base Node, allows
multiple ‘hops’ for greater system range, uses
combination of Relay and End Nodes.
Nodes –
975NR — Relay Node
capacity for 3 WATERMARK Sensors,
1 Temperature Sensor, 1 Switching Gauge
and 1 Rain Gauge. Node has 25' (7.6 m) Cable
975NE — End Node
capacity for 3 WATERMARK Sensors,
1 Temperature Sensor, 1 Switching Gauge
and 1 Rain Gauge. Node has 25' (7.6 m) Cable
Data Collection Devices –
CAT. NO.
975L
Logger
& 5WBattery Pack
used to collect data from the Base for manual
retrieval and display on a laptop computer.
(Includes Solar Panel)
975P
PC Link
desktop link to continuously stream data to the
WEB portal through your computer.*
(One PC Link is required for each direct to
computer connection.)
975G-BP —
Cellular Gateway & 5WBattery Pack
data transfer to Internet via Cellular Modem.*
(Includes Solar Panel)
975G-V-BP —
Verizon Cell Gateway & 5WBattery Pack
data transfer to Internet via Verizon Cellular
Modem.*(Includes Solar Panel)
To confirm current web-service pricing and pricing of new features as they arise, log in to
http://sensmitwebdiv.com/sensmitwebpricing2017/ using the password: irromesh2017.
*
WEB Based Data Service –
(required for PC Link and Cell Gateways and optional for Logger).
Manages and displays data online in real time. Payable by credit card
online at WEB portal.
Accessories –
200
SS-15
WATERMARK Sensor
15' (4.5 m) lead wire (3 per Node max.)
200TS
Temperature Sensor
15' (4.5 m) lead wire (1 per Node max.)
7- __ __ __ -ADS — Switching Gauge
(PSI Range choices: 15, 30, 60, 100, 200, 400)
900RG
Rain Gauge
BC
Bird Cover
Factory mounted upon order or available
as a retro-fit cap.
Also available as a non-meshing, point to point
monitoring system using all End Nodes.
Call IRROMETER
to ask about the Star System.
LANDSCAPE AUTOMATION PRODUCTS
Overrides entire irrigation controller operation when
soil becomes wetter than the moisture setting. Wires to
the sensor input connections of an AC irrigation controller.
WS-1 Module takes hourly readings from a single sensor, which is buried in the
root zone of turf grass. Select from four moisture levels or the bypass position
for sensor control override. Includes WS-1 control module, one WATERMARK
#200SS-X Sensor, and 2 direct burial wire nuts. Weather resistant solid state
electronics. Packaged for display.
Overrides valve operation when soil becomes wetter than the moisture setting.
Allows any 24 VAC solenoid valve to be controlled individually by two moisture
sensors located in the soil at different depths of the irrigated area. Takes a
reading each time the valve is programmed to operate. Also used to interrupt
controller master valve circuit or common, to override entire irrigation
controller. Select from 11 moisture levels or bypass position for sensor control
override. Includes WEM control module and two WATERMARK #200SS-5
Sensors. Weather resistant solid state electronics. Packaged for display.
MHS — Wired
CAT. NO.
MHS
Multiple Hydrozone System
(wired base unit)
200SS-5PR
Pair of WATERMARK Sensors
(with 5' [1.5 m] leads)
MHS-XB
Expansion Board
(additional 16 station capacity)
MHS-TD
Time Delay Kit
(for Pump Start Relay systems. Required for
irrigation control systems using a pump start
relay to activate pumps.)
W-MHS Wireless Multiple Hydrozone System
(includes base receiver & 15' [4.58 m] connection cable)
MHS-T
Wireless Transmitter
(serves 2 hydrozones & comes with 4 WATERMARK
Sensors, each with 5' [1.5 m] lead)
MHS-XB
Expansion Board
(additional 16 station capacity)
MHS-C
Base Receiver Connection Cable
(50' [15.58 m])
MHS-TD
Time Delay Kit
(for Pump Start Relay systems. Required for
irrigation control systems using a pump start
relay to activate pumps.)
Battery powered version of the WATERMARK
Electronic Module (WEM) for use with battery powered
(DC) irrigation controllers that have sensor input connections. Every five minutes
module reads two sensors, which are in the soil at different depths of the
irrigated area. Overrides controller operation when soil is wetter than the setting.
Select from nine moisture levels or bypass position for sensor control override.
Includes WEM-B control module, two #200SS-5 Sensors and 9-volt battery.
Weather resistant solid state electronics.
951/682-9505 www.IRROMETER.com
Simple
to use!
6
LANDSCAPE
Nomenclature
for ordering:
MHS – 4 – 1
Number of Sensor pairs
Number of Expansion Boards if needed
(1 or 2)
W-MHS
This system allows independent moisture control
of valve groups when all valves share a
common
ground. The MHS (Multiple
Hydrozone System)
interfaces with any 24 VAC irrigation controller for
soil moisture automation. Valves are grouped into
hydrozones based on that location’s specific
irrigation needs. As many as eight independent
moisture sensing locations can be managed. Each
hydrozone will interrupt the irrigation cycle based
on plant’s demand for that location and can be
independently programmed for the desired
moisture level. Components are factory wired and
mounted in a stainless steel enclosure (9 x 12 x 5''
[23 x 30 x 12.7 cm]).
This system logs data then reports moisture
values and saved irrigations to the user.
Soil Moisture Manager
FEATURES –
• Easy to Install — New or Retrofit
• Individual Area Moisture Control
Reads, Reports, Adjusts
• Override for Manual Operation
• No Maintenance
BENEFITS –
• Saves Money, Water and Energy
Automatically Reports Watering History
and Irrigation Water Savings
• Data can be Downloaded for Analysis
• Grows Healthier Turf and Plants
• Reduces Runoff
• Wireless
Solar Powered Radio Transmitter
with 1500'
(457 m)
Line of Sight Range
No Batteries Required
Saves Installation Labor – particularly
useful in retrofit applications
Base unit handles up to 16 stations/valves. Add 1 or 2
Expansion Boards for each additional 16 valves (48 max).
For example:
MHS with 4 Sensor pairs and
1 Expansion Board
is MHS-4-1.
Nomenclature
for ordering:
W-MHS – 4 – 1
Number of Hydrozones
(2, 4, 6 or 8)
Number of Expansion Boards
if needed
(1 or 2)
W-MHS — Wireless
For example: W-MHS with 4 Hydrozones
(2 Transmitters) and 1 Expansion Board is
W-MHS -4-1.
CAT. NO.
WS1 .................................
(includes 1 sensor)
CAT. NO.
WEM-B ...........................
(includes 2 sensors)
For Valve Control –
For Controller Sensor Circuits –
CAT. NO.
WEM ............ (includes 2 sensors)
CAT. NO.
WEM-DC-T ... (includes 2 sensors)
Dry contact switch version with
integral timer for use with the sensor
connection on a controller.
For Residential Systems – For Battery Controllers –
951/682-9505 www.IRROMETER.com
Use
Water
Wisely!
7
Coring Tool Kit
— Nickel plated 7/8'' (22 mm)
soil coring tool. Comes as a kit in fabric storage
pouch with two 12'' (30 cm) extensions and
handle for making up to a 36'' (90 cm) access
hole. Can also be used for soil sampling.
CAT. NO. 1013
Auger Tool Kit
Nickel plated 1'' (25 mm) soil
auger. Makes oversize hole for grout style
sensor installation in hard or rocky soils. Comes
as a kit in fabric storage pouch with two 12'' (30
cm) extensions and handle for making up to a
36'' (90 cm) access hole.
CAT. NO. 1014
Specialty accessories available for deep installations, consult factory for pricing and availability.
Slide Hammer
Steel slide hammer with
7/8'' (22 mm) diameter x
48'' (120 cm) long
insertion tip, calibrated
every 12'' (30 cm).
Top of tool is sliding
hammer that drives
tip into, and back
out of, the ground,
leaving a smooth
borehole for
sensor
insertion.
CAT. NO. 1012
, SSAT or Installation Tools
Extension Rod
12'' (30 cm)
extension rod for #1013 or
#1014 (above) for making
deeper access holes.
CAT. NO. 1015
Turf Coring Tool
Turf style
installation tool for shallow
sensor installation depths, to
12'' (30 cm). Nickel plated 7/8''
(22 mm) soil coring tool with
integral handle. Can also be
used for soil sampling.
CAT. NO. 1016
WATERMARK Insertion Tool WATERMARK
Sensor insertion tool. Tee handle style tool for
inserting the WATERMARK Sensor up to 30"
(76 cm) into the borehole created by one of the
tools shown here. Has internal ejection rod
inside tube to push sensor off of tool once fully
inserted into borehole.
CAT. NO. 1017
Repair Prices
CAT. NO.
R1 Recondition IRROMETER R, SR or TG
(includes new tip, stopper, complete cleaning and gauge check)
R1-LT Recondition IRROMETER LT or MLT
(includes new tip, stopper, complete cleaning and gauge check)
R2 Repair Gauge – R, SR or TG
R2-LT Repair Gauge – LT or MLT
R3 Re-Tip IRROMETER only
1008 New Gauge
CAT. NO.
1008-LT New LT Gauge
1008-
MLT
New MLT Gauge
New Body
(less gauge)
EXTEND Extend IRROMETER
RHVP
Recondition Hand Vacuum Pump (plus parts)
TRADE-IN
Trade-In Plan
(exchange old for new)
CONVERT
Convert Model “R” to “SR”
(replaceable tip)
(add to recondition or re-tip cost above)
IN NORTH AMERICA ONLY
Call IRROMETER for a Returned Goods Authorization (RGA) number then
ship via UPS or U.S. Postal Service prepaid to: 1425 Palmyrita Ave., Riverside, CA 92507
IRROMETERSSATWATERMARK
Available upon request
COMPANY, INC.
LITHO U.S.A. (12/16) #9
Warranty:
The IRROMETER COMPANY warrants its products against defective workmanship or materials
under normal use for one year from the date of purchase. Defective parts will be replaced at no charge for
either labor or parts if returned to the manufacturer during the warranty period. The seller’s or manufacturer’s
only obligation shall be to replace the defective part and neither seller nor manufacturer shall be liable for any
injury, loss or damage, direct or consequential, arising out of the use of or inability to use the product. This
warranty does not protect against abuse, shipping damage, neglect, tampering or vandalism, freezing or
other damage whether intentional or inadvertent.
951/682-9505 www.IRROMETER.com
Call
Us!
8
Optimizing Irrigation . . . Maximizing Conservation . . . Worldwide . . . Since 1951
LENGTHS 6 in. (15 cm) 12 in. (30 cm) 18 in. (45 cm) 24 in. (60 cm) 36 in. (90 cm) 48 in. (120 cm) 60 in. (150 )cm
.383 kg .439 kg .496 kg .553 kg .666 kg .780 kg .893 kg
.844 lb. .968 lb. 1.09 lb. 1.22 lb. 1.47 lb. 1.72 lb. 1.97 lb.
SSAT Tubes .080 kg .115 kg .150 kg .185 kg .255 kg .325 kg .395 kg
.176 lb. .254 lb. .331 lb. .408 lb. .562 lb. .717 lb. .871 lb.
200SS
WATERMARK Sensor
...................................................... .071 kg .......... .157 lb.
30-
KTCD-NL
WATERMARK Meter
........................................................ .341 kg .......... .752 lb.
WEM, WS1
WATERMARK Modules
................................................... .23 kg ............ .5 lb.
900M
WATERMARK Monitor
..................................................... 2.27 kg ........... 5.00 lb.
975NR
IRROmesh Node (Relay or End)
..................................... .69 kg ........... 1.53 lb.
975B
IRROmesh Base
............................................................... .70 kg ........... 1.54 lb.
975L
IRROmesh Logger
........................................................... .97 kg ........... 2.14 lb.
975P
IRROmesh PC Link
.......................................................... .272 kg ......... 9.6 oz.
975G-BP
IRROmesh Cellular Gateway/ Battery Pack
.............. 4.98 kg ......... 11.0 lb.
All
prices F.O.B. Riverside, California, and apply to North America.
(U.S. Dollars)
Terms — Cash, VISA, MasterCard with order or C.O.D.
Terms — Net 30 days with previously established credit
Prices and specifications subject to change without notice.
Show catalog number on purchase order.
Accessory Net Weights
KG. LB.
1001 Service Unit .....................................
.
484........ 1
.
07
1002 Test Pump Service Unit ..................
.
654 ....... 1
.
44
1004 IRROMETER Fluid .........................
.
085.........
.
187
1005 Monthly Chart (100) ........................
.
128 ........
.
28
1012 Slide Hammer .............................. 14
.
97 ....... 33
.
00
1013 Coring Tool Kit ................................ 1
.
36 ......... 3
.
00
1014 Auger Tool Kit ................................. 1
.
36 ......... 3
.
00
1017
WATERMARK Insertion Tool
.......... 1
.
36 ......... 3
.
00
7 Series
Gauge .............................................
.
170 ........
.
375
Weight and Measurement Information
Net Weights
MINIMUM ORDER CHARGE
If net invoice value of order is under $50.00 (not including shipping and handling),
there will be an additional $7.50 small order charge added to the invoice.
or
WEM-B
or
975NE
Shipping and Mailing Address:
1425 Palmyrita Avenue
Riverside, California 92507-1600
Phone: 951/682-9505
Fax: 951/682-9501
Email: sales@IRROMETER.com

Navigation menu